Loading...
HomeMy WebLinkAbout2941 Eaton StreetCity of Wheat Ridge Residential Roofing PERMIT - 201704159 PERMIT NO: 201704159 ISSUED: 07/17/2017 JOB ADDRESS: 2941 Eaton ST EXPIRES: 07/17/2018 JOB DESCRIPTION: Residential Re -roof to install CertainTeed Northgate dimensional asphalt shingles - 23 sq *** CONTACTS *** OWNER (703)830-1680 MCDONALD CLAUDIA SUB (303)346-6010 Roy Thomas 090287 Mountain States Home Improve *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,000.00 FEES Total Valuation 0.00 Use Tax 168.00 Permit Fee 172.60 ** TOTAL ** 340.60 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. INSPECTION RECORD 0ccu1)4__c,,'T31q INSPECTION ONLINE F,DRM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) o receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underaround or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw I Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather ® i A 4' City of Wheat Ridge Residential Roofing PERMIT - 201704159 PERMIT NO: 201704159 ISSUED: 07/17/2017 JOB ADDRESS: 2941 Eaton ST EXPIRES: 07/17/2018 JOB DESCRIPTION: Residential Re -roof to install CertainTeed Northgate dimensional asphalt shingles - 23 sq *** CONTACTS *** OWNER (703)830-1680 MCDONALD CLAUDIA SUB (303)346-6010 Roy Thomas 090287 Mountain States Home Improve *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,000.00 FEES Total Valuation 0.00 Use Tax 168.00 j Permit Fee 172.60 ** TOTAL ** 340.60 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201704159 PERMIT NO: 201704159 ISSUED: 07/17/2017 JOB ADDRESS: 2941 Eaton ST EXPIRES: 07/17/2018 JOB DESCRIPTION: Residential Re—roof to install CertainTeed Northgate dimensional asphalt shingles — 23 sq I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I ally authorized to include all entities named within this document as parties to the work to be performed and that all wo a ed is disclosed in this document and/or its' accompanying approved plans and specifications. ,77 Signature of OWNER or CONTRACTOR (Circle one) Date I _ This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off-cial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official 0 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett to W � I Residential Roofing Permit Application From: no-reply@ci.wheatridge.co.us Sent: Friday, July 7, 2017 2:11 PM This application is exclusively for new permits for residential roofs and for licensed To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application the order they are received and due to the volume of requests, time to process Categories: Dane (� PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if�. 1 your contractor's license or insurance has expired, and you may update those Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 2941 Eaton St Claudia Mcdonald 7038301680 Field not completed. Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in a the order they are received and due to the volume of requests, time to process 7;� varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR (� PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if�. 1 your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. --� For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 2941 Eaton St Claudia Mcdonald 7038301680 Field not completed. Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Mountain States Home Improvement Inc 090287 3033466010 Contractor Email Address andrew@mountainstatesroofinginc.com Retype Contractor Email Address DESCRIPTION OF WORK Are you re -decking the roof? Description of Roofing Material andrew@mountainstatesroofinginc.com No x Certainteed Northgate Dimensional Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 23 material selected above? Does any portion of the property include a flat roof? If yes, how many squares on the flat roof? No Field not completed. TOTAL SQUARES of all 23 roofing material for this project Provide additional detail Roof home, 5/12 pitch, t/o 1 layer to deck here on the description of 2 work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 8000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Andrew Thomas Email not displaying correctly? View it in your browser. 3 O 00 O v SJR _ o o IC 0-J C, v y o�.0 C y O L ! O o auc f`' ao� F- me _ Z. •� y O --,.,. l z -� aeo "m «? U i r„d 1 W 0 jCM rc E m E v J W1 WU. coLu j/�� U U J �I} } �,> �� T -I pkCL r �y l CL z. S ° w o N ! i 2 > > v w ° x N S t �°o a m o a E F4 rn � N C d o = y m y m w > °° ° m N E N y N O °� m N a E R E N c U O U co m N — y d Y C ee O. ° d N L 0 0 _` ¢ U F� m > w Q j d a U U Q � N Cr a ni of 6 of o C� C -i C y �^ J G'� m U U w= m 0 ~ c W z ro V Qz O c 0 _y U) c CD z, o LL00 (D O m o cc 0 QLL O m � Z � 0w J � a Wa- m0 `U y LL W > c W mU N m ¢ 3 _ O Z m (a cuiU) c c z T O ca gQ Ym �ILW y o O � OO N zzZ<�Q rn mN m IL C 0 o M 90-0 W 0co r 0 0- ¢ ¢ o m z w z oLu r zmo� W m Q U 7 y(JFW m m >Lu y QOM 0001 �a¢ m d � z2�o 0 0 �~W .0-8 a a 0 Z d d m¢0- m 0) mom>- �a U)cr m y N 0O (OW N U W w N m ¢Z 0 zo m QU Z m >U> � �0 O Z V 0- rn_ EQO�-cam o � d X W J aco P _m U Z W 2 J O IL CO a a ¢ L l O O a1 N T a C � U L t� n. 1,J J a) U U U O O_ C Gam., m F . � a) "= L m a a >, E c° 0 w o d a i c C U :Da m g 0 L)) a) o f :3 w� c E m c _. - 0= d -0 o E d o o' a) o Mal v! N of E �a oTN�o Nmc� C: E C w z m U O os a c v `� a°° o m is ° 3 N O 0) ca r o N ¢ E S a T c C aci o' v E c O •° m L U S N c �' d ca a) 7 O U 01 N� C> >, N m C° C 3 'O °¢ o p N a) -_° t0i z O c 3 N a 10 a`) U o c E Y°° ° m E u M Z ZLL ° ° a) O t m c .O 0 T M E 'O O o O. Y a) 3 a a E ca cu (--D E O_ O a) E� ca m- c N O LL O d d r 75 c ' CD L m° N S. ° 0 o 3 9 U ay � G d a O w o Cc E — O m Y `o o 0 ) � 0 m m o "a T g v -°c a; 0) ami Z y ° cd a w ; v 0 o `m m Urn a o °c o° ax o o in ° a) i y m c 7 m N c°� $ 0 a m LL Z c c> c ° o c ro a n c c Q _0 N ca -1 c° �o �° arwaEy aa) 6, - c U -1 �' 0a Eo .�� w NO�o ��vm 0 0 Lu a- `o N Qw rn E o= y3 >� °o �c occi - o°a�pO -oNoa macro nmvm a> E m m0 c my EY �o m$o�Eo -(C -2 M o O N 2 W 3 v i o E° .E c . 0 C C ° 0 0 a) -� 3° °' E a) a) mac° a) a) Q �O� m 1d �a =E �a`o o mJ----�O a) c c w Z T ° a7 C N C L°',°'EZI O t0 N 3 N _ O 0 CL O V > ca a CL ro _ N A N a) N O" C 0. 7 7 0 U N o) C .O CO N m a w .s 3 in E`o m e a) C °3 ?'m c c m C O a) �= o ro o ° �. g} a L� O d d v rn C `t CL ° o V a) y c°i m Y' '0 `o m LO) c Ca o ° A N N o Z O C 7 N N j o 0 0 O M o 6) YO a C N O N C .E at U a7 o C1 N co C O y d L O ro E 7 E T a) O N i 8 'O 1] F N .— N C d c U a) - C O) o w Z >i cn ZZaU� E yt �� N vc 7 U N tmaa))�c'a- a) 0 Ewy- o ca'v tq F O c3 3 .O >"y ag C Niw �a N al da)asc 9 L o "O a)yc DD O w d C ° i O) N N y O> C O U L a) a) Y N C C a7 > O C O caaUao U o C ca a) cc LL c.3 = N C a) ca 3 a) c E« E O1 o atea° E r w S¢ N O •O C �' O O) 3 C N C O J C d N 7 ° m a) 00-cr c -c6 Em Emom °a d o Ey m Z w 'O o r "t ' 3 ° m 3 E m o o c> CL 3 o c a) m -o c a$ c E c o Q o m ° U ca y Lu m n C CD 0C L �' O O C N j m N N O N N N U �' is "O 1 Q r d W J a) 2 O O C : 'a - i N a) C m C y- Q) pa U N -O > (n a) t 1 ww�� c >T N/ yr acid "O c o 0 MO: E c: a) S E C E wT � "O Cl) acY J Q V > E T a° of 0 y a3 O O C Y >, C O a_ 1 C 00 a p o• Cl) O " O. N C> O U a .` 'O a) Y O i' C is C O -20 'U a) N a) "O L C Y N 7 O O 'O O> a) U . cc .� m <w d ° m 30) �n a) " in `a m 7 C) m >, -_ c°i p_ a'_) o a) CL }Z °• O O' 0 ° C S ca 0 0 d 3 cc O O N a r~ w o v nl c L O 3° 0 0 0 a o 3 m 3 E° Y. ° a c "= O °°> Mn L > o o F a O°c)a m N V a- N Q N C ° Mn N« r ca T O a) C 0��cm ?r >- 0 0 7 c o as _ o T— i) S O N •O Q v: Q ac) E 'O mr a T "O 1) C ms > E E tM QcL) fn a) L FEin a) m -o°o E m M E ¢QQ aa)) U- y f° c°i d a - 3 3 0°-0 d a)FE 'r- 3 3 -- m y o rn >- ¢ m Y J 0 7 2 axi E c> -° c c`a m m c a) S a)> O' "ca a. a° v c a) a) - c L y c 0 N U¢ m N O y o C a a E C U "O d m E O C = o a m 3 .3 N a7 N o° — a) 3 E n O 3 U ¢ z ° t0 c c > E > `� y a) a o c to - m m c m a Q) C a) < H¢ O o O_ O °a D L�E ca T cc U N ac1 ZS A - oo y c m C °a C `a NE y o cE Z Ir U 0' t a) ro a) O n o°'o NNO)0 N 3 ° a Xda EaSo O oCzz C = O ld — 0 Em D20E O04) °a 0°0ai ') 0-0' wJ m c 0i o miE f a c o --c- o¢U Q � o E c aiz a) `.N o C) w J❑ Oo O C aa) —r yID U -. s L E 0.0 NN .U U Y) y ¢ 00 16 O t = mo a¢¢ T 2 c 2 0 3 o U z "C A � U L t� n. C N d O i c S N O U _. E -0 c ca _. aCa o 0- -o .� C: a7 (6 O y1 -- w. . m E U a) CL o CL V co N as O E ca C O- m a Y m .L E j�� U ca o c m N C O U R .n ca J a m c N A � ca tt N N \. c cc O w .1 conn a) Q G ! °a o o a p O E rn a) � m i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 -Office- (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: f `ll' Permit Number: �_f �'�l� ell S ❑ No one available for inspection: Time C 2 ±2 AI /PM Re -Inspection required: (Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: —40-? � ?��ZI � Inspector: - I DO NOT REMOVE THIS NOTICE 1 i CITY OF WHEAT RIDGE ; Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: .- 'ac Job Address: 51 Permit Number: ❑ No one available for inspection: Time 0 A' /PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: In ector: / r DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: ;4ql e7 -/0e7 cfi Permit Number: ®2 0 >0 C// 5-7 ❑ No one available for inspection: Time ! f' AMMA0 Re -Inspection required: Ye Nd When correction h7i- een made, call for re -inspection at 303-234-5933 Date: Inspecte---; )`Cry �T DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line _:��P�(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M 0 Job Address: Z i I EAT/%J .1 Permit Number: I() LJ I S�1 f f ❑ No one available for inspection: Time N' n' - AM/M Re -Inspection required: Yes N_ o> r' When corrections have been made, call for re -inspection at 303-234-5933 Date: (Z", Inspector_.� 141c>� 1DO NOT REMOVE THIS NOTICE City of re Building rr ion Serv Division 7500 W, 29"' Ave_ Wheat Ridge, CO 80033 ffi : 303-235-2855 * Fax: 303-237- Inspection Request Liner 303-234-59 ��, ,IiII111� Property Address. Date: Plea rrit Property Owner (please arint ) . � � � � r� : " ' ' Andress: C , City, State:, Zip: r Contradors City L tsrn2 4 Electrical: Plumbin hanical: City License # C ity License # City License (Fully desc worts to be pe rformed A ttach a dditional sheet If necessary) xc4 a - ` }` .: Val of all q y Review Fee due at * f s ubmittal): Sq uares ., Tel" Gallons _ Amps Sq fit. ORCIXONN: (MUNER) (CON°"', O) gr fy C C s1 1 k i4 1 1 o ( Xi` ER) W ,°k'TRAC `OJ?r a" Bldg Valuation -7 APPROVED Subject to Field Inspections Wheat Ridge Building De to 5"5 1 - Date: Sign Ian checker 9MMEM�� Project: Heard Residence - Project # 8021330 2941 Eaton St Wheat Ridge, CCl 80214 u3ma�� installation is the solar • addition to me root. i me structural review, incluoing the an ano calculations only apply to the section of roof that is directly supporting the solar PV system and its supporting elements. After review it was determined that the existing structure requires a structural upgrade, The required upgrade is shown in the structural drawings on the SolarCity drawing set. _DesignCriteria, • Applicable Codes = 2009 IBURC, ASCE 7-05 and 2005 N • Roof Snow Load = 30 psf • Roof Dead Lead= 9.5 psf (All MPs) • Basic Wind Speed = 100 mph Exposure Category B • Solar modules = As indicated in attached drawings, ,gravity loading due to the it panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the 2009 IBC M= NNUFAM I rd LOJMG mag I I a lzmm 4 9 301 # -'SolarCity 3055 dear V n CA, STRUCTURAL DESIGN CALCULATIONS by JOHN CALVERT, P.E. SolarCity, Inc. 3055 2x« ®. Way San Mateo, CA, 94402 888-765-2489 OWNER: Heard, Jason 2941 Eaton St Wheat Ridge, CO. 80214 (719) 238-8573 P&*JECT DESIGINED B" SolarCity, Inc. 3055 Clearview Way San teo, CA Ma. 94402 88■-765-2489 1 Oil 928/2013 8021330-Heard.xlsx Solart"Ity s ry n 4 02 v v, . . ,.Fsa Ivy 4 Calculations by: JAEN Reviewed by: JAM Table of Contents Note: SOI IC Check IS not reaulred because Ss = 0.224 < OA9 per 1613.11 to 2009 IBC ( . .......... .. 2/2812013 8021330-Heard,xlsx Wind 4 M Fe guired Kariab Design Wind Pressures based upon: mean roof height, ft 15 ASCE 7-05 Chapter 6 Wind Loading Exposure Category (6,5,6.3) B Basic Wind Speed (Figure 6-1 or local data) 100 Equation 6.5.12.4.1: h<60 ft Comp, and Cladding Elements Importance Factor (1 for residential) I Wind Pressure P = qh*(G*Cp) Roof Shape Gable/Hip 6.5.10: VeIogqy_E[gsears Panel Tilt (degrees) 22.6 deg qh = 0.00256*Kz*Kzt*Kd*VA2*1 Roof Zone 3 E - Pm.. = .244 :3 contiguous sq. feet of array 17 From Table 6 -: least width of the building 20 Kz = 0,70 X (distance between standoffs 4.00 From Figure §-4, Y (distance between standoffs in ft.) 2.75 Kzt = 1.00 Local Tmogop lit cal Eea 10.83 From T abig 6A_ (choose "standard ' or refer to pictures right, and below) Kd = 0.85 type of hill none Prow §-I Hill Height (h) (ft) V= 100 slope of hill (degrees) From _table 6 -1: horizontal distance from hilltop to house(x) 5AI I= 1 height from bottom of hill to mean roof height(z) 109 PVPL= 33 Mm (weight of Tlina TSM-240PC modules) 4100 From Velocity Pressure Equation: Mh (weight • hardware per module) 710 qh = 15.23 Design Wind Pressures From fLqare 6 -1� P (tbs. per sq. ft.) = qh Cn (down) = 0.46 Pd (downforce pressure) = 6.93 Cn (uplift) = -1,59 Pu (uplift pressure) = -24.19 r, = 0 AS Max Tributary Area do Max Uplift Force on a Single Stanff Individual Rows in Portrait Pmax (tbs.) = Amax*Pu + 06*PVCOSO Trina TSM-240PC E - Pm.. = .244 :3 Amex (sq. ft.) = O.S*L*X Factor of Safety = Ft* ax L (length of panel in ft. perpendicular to rail 5.41 Fastner Type: Hex Lag Screw (Per Plans) X (distance between standoffs 4.00 Fastener Diameter 5116" - 2.5" Min Embed Y (distance between standoffs in ft.) 2.75 250 = Ft (pullout capacity of fastener (lbs/inch)) Amex 10.83 2,5 = D (minimum fastener thread depth) I = NI (number of fasteners per standoff) 2.56 = Factor of Safety Qgad koa �Zgicula& Qt - • (tbs/sq. ft.) = (Mm+Mhy(L*W) Point kead ga cuts L (length of Trina TSM-240PC modules) 5AI PL (tbs) = Amax*Loading W (width • Trina TSM-24OPC modules) 109 PVPL= 33 Mm (weight of Tlina TSM-240PC modules) 4100 Mh (weight • hardware per module) 710 2128/2013 8021330-Heard.xlsx Flush DL 5 All JI MODULE AND STAND-OFF CHARACTERISTICS N = 13 L.. = 5.41 ft WM0d 109 ft A 16,71 sf Wtmld 4100 1b DL = 2.57 psf Solar Rail Make & Model: Solar City Rail Solar Rail Configuration X-X Solar rails running in X-X direction 1 1prrtiillrt�� 0 = 22.6 deg Tilt • panel system from horizontal 0 100 22.6 deg Slope of roof mounting surface h min O33 ft Least panel height above roof surface (vertical dimension) , hMax 033 ft Greatest panel height above roof surface (vertical dimension) h = 033 ft Mean panel system height above roof surface (vertical dimension) L ® = 3.09 It Array length in X-X Direction Sx-x = 4.00 It Standoff spacing in X-X Direction II = 1 Number of standoffs in X-X Direction LY-Y = 70,37 ft Array length in Y-Y Direction (actual dimension at panel tilt 0) Lh,y-y 64.96 ft Horizontal projection of array length in Y-Y Direction SY-Y = 2.75 ft Standoff spacing in Y-Y Direction N = 26 Number of standoffs in Y-Y Direction 2923!2013 3021330- Heard.xlsx Flush DL DETERMINATION OF SYSTEM DEAD LOAD FOR SEISMIC ANALYSIS COMPONENT AREAS, LENGTHS, AMC? QUANTITIES A , = 217 sf gross area of solar PV system Aff,dules - 217 sf Net area of scalar modules only N rai : 25 Number of solar mounting rails L..„ = 80 ft Approximate total length of solar mounting rail Nstanftff - 26 Number of stand -off assemblies Subtotal +o r Hardware = 100 lb Total DL = • • lb Weight of Hardware per solar Module = 7.70 lb Weight of Modules per square foot of PV System = 2.57 psf Weight of Hardware per square foot of PV System 0.46 psf Total Seismic System Weight per square foot = 3.03 psf fir- Length or Unit Component Component Quantity Wight Weight, lb Solar Modules 13 x 43.00 lb 559 Solar Rails 30 ft x 0,68 pif 55 Stand -off Assemblies 25 x 1.75 lb - 45 Subtotal +o r Hardware = 100 lb Total DL = • • lb Weight of Hardware per solar Module = 7.70 lb Weight of Modules per square foot of PV System = 2.57 psf Weight of Hardware per square foot of PV System 0.46 psf Total Seismic System Weight per square foot = 3.03 psf fir- 2/28/2013 8021330-Heard.xlsx Roof DL 7 DETERMINATION OF DEAD AND LIVE LOADS: All MPs DEAD LOAD IBC 1607. 11.2 Element Materials Wt. SD Roof: Comp Shingle 5.00 Roofing Paper 0.50 1/2 in, Plywood or CAB 1,50 2 x 6 @ 24 in. o.c. 1A5 (Top Chord) Miscellaneous 1,35 9.50 Roof Pitch 5:12 1.083 22.6 deg Dead Load @ Roof Pitch = 1029 Ceiling: 2 x 4 @ 24 in, o.c. 0.73 (Bottom Chord) Insulation 1 A2 5/8 in. Gypsum Board 2.80 Miscellaneous 1.50 &45 LIVE LOAD IBC 1607. 11.2 L = 20 psf Atnb = <= 200 sf R, I R2 0.95 L,= L * R, * R2 = 19 psf BEAM RELATIVE STIFFNESS Distribution of Gravity Loads to Existing Rafter and (N) Side Member (Sister Rafter) ROOF LOAD SUMMARY mmm�s RAFTER MEMBER SUMMARY Member Nominal Size Species b d E I El Description & Mill Finish & Grade (in.) (in.) (psi) (in.) (lbhn.')*(in.') (E) Rafter: 2 x 6 Surfaced DF2 1.50 6.50 1,600,000 20.80 33,275,000 (N) Side Member: 2 x 8 Surfaced SPF 2 1.50 7.25 1,400,000 47.63 66,688,672 (Sister Rafter) tw eAWAF t 16 K F,&VW' 11 1� - T Loadsm El 66,688,672 - = 0.667 EIER + El 33,275,000 + 66,688,672 Based on Relative Stiffness, 66.7 percent of the load is carried by the New Side Member (Sister Rafter). DL = 634 psf Uniform Dead Load distributed to (N) Side Member, relative to Stiffness Sl 20.01 psf Uniform Live Load distributed to (N) Side Member, relative to Stiffness Pl 22.0 lb Point Load from PV system distributed to (N) Side Member, relative to Stiffness BEAM (RAFTER) CALCULATION METHOC 11, 111 11 • g • , • 6&010 - i Ming I Ira a if #i;u amu Ila Ls r4mil w1ga EjE , • , cH tj mam - , , • 01 M COMPANY PROJECT WoodWorks(I" Feb. 28, 2013 15;29 NPI,wwb [design Check Calculation Sheet Woodworks Sizer 9,21 Loads. Load Type Distribution Pat- Location [ftl Magnitude trait tern Start End Start End DL Dead Full Area 3.16 (24.03)* psf SL Snow Full Area 10.00 (24,0)* p f PVDL Dead Point 1.94 11 lb PVDL2 Dead Point 4.61 6 lbs PVDL3 Dead Point 7.03 11 lbs PVDL4 Dead Paint 9161 6 lbs el -wei ht Dead Fula L 3.3 of *Tributary width (in) Maximum Reactions (lbs), Rearing Capacities (lbs) and Bearing Lengths (in) 0$ 13' -4" Unfact.red: Dead 90 84 Snow 134 134 Factored; Total 224 217 Bearing: F °theta, 475 475' Capacity Joist 732 71.2 Supports 1055 1055 Anal /Des Joist 0.31 0.31 Support 0.21 0.21 Load comb #2 #2 Length 0.50* 0.501* Min reg'd 0.50* 0.50* Cb 3.00 1.043 Cb min 1.00 1.00 Cb support 1.13 1.13 Fc su 625 625. * lV mmush bearing length setting used: 162" for end supports MPI Lumber n -ply, -P -F, No.111~ o.2, 24, 2-ply (3"x5-112") Supports: All - "timber -soft Beam, D.Fir -L No. Roof joist spaced at 24.0" c1c; Total length: 14'- 8.2 ° "; Pitch: 5.0612;. Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help); Analysis vs. ,Allowable Stress (psi) and Deflection (in) using NDS 2005: Critericsn as sis Value Desi n Value a2 ais /Deal n Shear fv 18 FV' = 155 CV1Fv' - - 0 11 Bending( +) fb = 593 Fb" = 1504 fb /Fb' = 0.39 Live Def2'n 0.29 w L/604 0.72 = L/240 0.40 Total Defl "n 17,58 = L/300 0.96 - L /180 0.60 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF CfU Cr Cfrt Ci Cn LC# FV 135 1.15 1.00 1.00 - - - - 1.130 1.00 1.00 2 Fb 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1,00 1.00 - 2 Fcpl 425 - 1.00 1,00 - - - 1100 1.00 - El 1.4 million 1.00 1.00 - - - 1.00 1.00 2 CRITICAL LOAD COMBINATIONS: Shear i LC #2 = D+S, V = 206, V design = 194 lbs Bending(+) : LC #2 = D+S, M = 747 lbs-ft Deflection: LC #2 = D+S (live) LC #2 = D+S (total) Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LCIs are listed in the Analysis output Load combinations: ASCE 7-05 / IBC 2009 CALCULATIONS. Deflection: El = 29eO6 lb-in20ply "Live" deflection = Deflection from all non-dead loads (live, wind, snow-) Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. Design Notes: 1, WoodWorks analysis and design are in accordance with the ICC Intemational Building Code (IBC 2009), the National Design Specification (NDS 2005), and NDS Design Supplement. 2 . Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4,41 4. SLOPED BEAM& level bearing is required for all sloped beams. +r•# �# II MAIM •.+ Load Type Distribution Pat- Location Utl Magnitude Uni 150 Snow 268 tern Start End. Start End DL O25 = Dead. 431 Full Area 0.35 418 6.34 (24. psf SL L/180 Snow F'theta Full area 20.00 (24,0) * :psf Capacity PVDL Dead Point 710 1.94 22 Ibs PVDL2 10555 Dead Point Anal/Des 3.61 11 lbs PVDL3 Joist Dead Point 0159 7.03 22 lb PVDL4 0.40 Dead #2 Point 9.61 12 lbs Self - wei tat Dead Min reel "d FuLI UDL 4.4 if *'P"ril-�iat:�rar ta7irit•.h (in) 1.00 Cb min 1,00 1.00 s tlnfactored s Dead 153 150 Snow 268 258 Factored: Live DeflIn O25 = Total 431 L/240 0.35 418 Bearing L/180 0.50 F'theta 474 474 Capacity Joist 710 710 Supports 10555 1055 Anal/Des Joist 0.51 0159 Support 0.41 0.40 Load comb #2 #2 Length 0.50* 0.80* Min reel "d 0.50* 0.50* C b 1.00 1.00 Cb min 1,00 1.00 Cb support 1.1:3 ' 1.13 Fcn sun 1 525 525 iiiii f T # ## MPI Lumber n =pl S -P -F, No.1 /No.2, 2me13, 2-ply (3 *W -114 ") Supports: All - Timber-soft Seam, D. it -L No. Roof joist spaced at 24.17" ctc; Total length: 14'-8.9"; Bitch: 5.0/12; Lateral support: top= full, bottom= at supports, Repetitive factor: applied where permitted (refer to online help); Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 005 Live DeflIn O25 = L/692 O72 L/240 0.35 Total DeflIn 0,48 = L/180 0.50 El �m Additional Data: FACTORS. F/E(pSi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# FV 135 1.15 1<00 1,00 - - - 1100 1.00 1.00 2 Fbl+ 875 1115 1.00 1.00 1.000 1.200 1,00 1.15 1.00 1100 2 Fop 425 - 1.00 1.00 - - - - 1.00 1.00 - E, 1„4 Million 1.00 1.00 - - 1.00 1.00 2 Emin' 0,51 million 1,00 1,00 - - 1.00 1100 2 CRITICAL LOAD COMBINATIONS: Shear z LC #2 = D+S, V = 397, V design = 365 lbs Bending(+): LC #2 = D+S, M = 1437 lbs-ft Deflection: LC #2 = D+S (live) LC #2 = D+S (total) Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 D-dead. L-live S=snow W=wind I= impact Lr=roof live Lc=concentrated E-earthquake All LC's are listed in the Analysis output Load combinations: ASCE 7-05 / IBC 2009 CALCULATIONS: Deflection: EI = 67e06 lb- n2/ply "Live" deflection = Deflection from all non-dead loads (live, wind, snow,,,) Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. Design Notes: 1, WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC 2009), the National Design Specification (NDS 2005), and NOS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application, 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4,1 4. SLOPED BEAMS: level bearing is required for all sloped beams. Load Type Distribution Pat- tern Location [ft) Start End magnitude End unit DL Dead Roll Area No Fl�/Fv' _ 9.00 (24.0) * _ psf SL Snow Full Area Yes fb/FbI = 30.00 (24,0)* psf PVDL Dead Point No 3.10 33 lbs PVDL2 Dead Point No 5,77 17 lbs jsetljjLHti 23 t]Dead 442 Full UDL No 79 1.1 —Pif — -Trioutary wiatt (in) =I 4'-10" T-9" Unfactored: Sxsa1 sis value value AnaWlsis/Design _=0 Shear fV = Dead 48 155 Fl�/Fv' 144 Bending(+) fb = 14 Snow 124 fb/FbI = 0,39 298 fb = 784 64 Factored: — 0.46 Live DeflIn 0.06 = L/948 0.25 = L/240 Total 172 Total DeflIn _0.11 = 442 0,34 = L/180 79 Bearing; — FItbeta 458 458 458 Capacity Joist 343 601 343 Supports 586 586 586 Anal /Des Joist 0.50 0.74 0.23 Support 0,29 0.75 0.13 Load comb #3 #2 #4 Length 0,50* 0.50* 0.50* Min req'd 0.50* 0.38** 0150* Cb 1.00 1.75 1.00 Cb min 1.00 1.75 1.00 Cb support 1.25 1,25 1.25 Fora sole 625 625 625 III t la MP2 Lumber-soft, a- -F, No.I/No.2,2x4 (1-112"x3-1/2") Supports: All - Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 24.0"c/c; Total length: 8'-3.7"; Pitch: 4012; Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help }; Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: criterion Sxsa1 sis value value AnaWlsis/Design _=0 Shear fV = . ,Desiqn 63 FV' = 155 Fl�/Fv' 41 Bending(+) fb = 679 FbI = 1736 fb/FbI = 0,39 Bending(-) fb = 784 Fb' = 1717 fb/Fbl = 0.46 Live DeflIn 0.06 = L/948 0.25 = L/240 0.25 Total DeflIn _0.11 = L/562 0,34 = L/180 0.32 �10 M Additional Data: FACTORS: F, /S(psi)CD 01 Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fv 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fbl+ 875 1.15 1.00 1,00 1,000 1.500 1.00 1.15 1.00 1,00 - 3 Fb 875 1.15 1,00 1,00 6.989 1,500 1.00 1.15 1,00 1,00 - 2 FCp' 425 - 1.00 1.00 1.00 1100 - - E, 1,4 million 1,00 1.00 1.00 1.00 - 3 Em n' 0.51 million 1.00 1.00 1.00 1.00 - 3 CRITICAL LOAD COMBINATIONS, Shear ; LC #2 = D+S, V = 243, V design = 220 lbs Bending(+): LC #3 = D+S (pattern; Ss), M = 173 lbs-ft Bending(-); LC #2 = D+S, M = 200 lbs-ft Deflection: LC #3 = (live) LC #3 = (total) Bearing: Allowable hearing at an angle FItheta calculated for each support as per NDS 3.10.3 D=dead L-live S=snow W=wind I=impact Lr=roof live LC=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: S=S/2, X-L+S or L+Lr, =no pattern load in this span Load combinations: ASCE 7-05 / IBC 2009 CALCULATIONS: Deflection: El = Se46 lb-in2 "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. w..., �a 2/2812013 8021330-Heard.xlsx U S 10 Period Sa (sec) (g) O S Class 1.0 0.138(SM1, Site Class] Pedod Sa (sec) (g) 0.2 0.239 (SDs, Site Class D) 1.0 OM2 (SDI, Site Class D) Y 1 0 m c Q c� �a. E a c a ui a 1 CD ZN C 0 h 0 I a. ul tCS ; vt Y ui S LW AS. O �".x.. 0 V3 tl w CL P Q K? I 20 v CJ Q ' , 40 - 0 t z m 4 0 W 4 1 0 uj > 0 m o > M— 6 tl3 U J o 00 z .E i UJ C-4 c ia r� ' LU } tra ry z H {"*$ !1 w M} uj }d QT Q. 0 W G U ui 6 t4 O �. O 0 CJ 4t1 t- 0 {,} $i SST co 0 0 k Ul !•- z yy + yy g p . p 4- tt li9 Q7 Ca" Y (0 ii. c s 0 4 2 C43 W Im 4 14 � ON $ w Ct sw# P 4i 91 4�'f H � C7 at t9 Ck c a 0 � ' 43 d � 41 ^+4 0 0 W" $ 40 C) w N 47 N Z , ri N 33 to ko p W V, W « e+d Lx v 0- w ri rt GR 0 $4 :IM 4 f4 (4 0 to Q $4 r4 Z t+t ry" w•I Q G3 Crb 0 fq T 40 16t k i 9. Pf4 f.R Ol Y 1 M , Y� { • • Y • YfS M' S, • • co rM M M Y � 4 ! y 0. M + s LU • • m w rt k i 1! • I 0 m c Q �a. E a c c� � ui a 1 CD ZN C 0 h 0 I a. ul tCS ; vt Y ui S AS. O �".x.. 0 V3 tl z L1 0 I 20 v CJ Q ' , 40 - e AK z m 4 0 W 4 1 0 uj > 0 m o > M— 6 tl3 o 00 z .E i UJ C-4 0 z H {"*$ uj I w 0 O �. f z CJ 4t1 {,} $i SST co 0 !•- z yy + yy g p . p tt li9 Q7 Ca" Y (0 c s 0 4 m 3 ek $ w t9 Ck c a F 43 d k N 9 41 ^+4 0 W" $ 40 C) w N >. uT N S p W V, W « e+d Lx v 0- BI 14 GR 0 $4 Z t+t ry" w•I Q G3 Crb 0 fq � 04 i 9. Pf4 f.R Ol ko J H U, D M , Y� { • • Y • YfS M' S, • • co rM M M Y � 4 ! y 0. M + s LU • • m w rt k i 1! • I 0 m c �a. E a c c� � ui a CD C 0 I a. ul tCS Y ui Co UJ �".x.. 0 V3 tl L1 0 20 v CJ Q ' , 40 - e z 4 0 uj > 0 m o > M— 6 tl3 o 00 z .E UJ C-4 0 M , Y� { • • Y • YfS M' S, • • co rM M M Y � 4 ! y 0. M + s LU • • m w rt k i 1! • I ABBREVIATIONS EL ICAO. NOT IN DEX LI JURIS I NOT A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CURRENT MEANS MAY BE ENERGIZED I THE OPEN PV2 SITE PLAN TYPE EC ` 6041 BL ALTERNATING BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL M EWS t CONC CONCRETE OF THE HAZARDS PER ART. 69017. PV4 STRUCTURAL VIEWS C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 THREE LINE DIAGRAM Wheat Ridge Building Departmer t D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 ELECTRICAL CALCULATIONS D DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. Cutsheets Attached provood EGG EQUIPMENT GROUNDING CONDUCTOR . A NATIONALLY- RECOGNIZED TESTING (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN L 3`I> EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL kity of Wn* The 4wmm of a pe it or appr oval of purls, %wifiations ALV GALVANIZED COMPLY WITH ART, 250.97, 250.92(B) CUT SHEETS ATTACHED atat's s shit t for, art approval of, sary viola bn to GEC GROUNDING ELECTRODE CONDUCTOR 5. D CONDUCTORS EITHER DO NOT ENTER P any of ft provisims of the buiWing code or of any City ordinance W*s presuving to give authority to violate or canmi the provisions S the GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS G ENERAL OYES buldin code or other or lsomes of the City shaO not be, w4ki, HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). 1. THIS SYSTEM IS GRID- INTERTIED MA A Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN UL-- LISTED POWER- CONDITIONING INVERTER. INVS Isc INVERTERS SNORT CIRCUIT CURRENT RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 2, THIS SYSTEM HAS NO BATTERIES, NO UPS. APPROVED kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND Subject O Field Inspections k KILOWATT L-- LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED: LBW LOAD BEARING WALL MANUFACTURER USING UL LISTEN GROUNDING 4, SOLAR MOUNTING FRAMES ARE TO BE GROUNDED 5. ALL WORK TO BE DONE TO 2009 INTERNATIONAL Wheat Ridge Building Dept, MIN MINIMUM HARDWARE.. BUILDING CODE. 11 p?b e " wA_ 1 MIR MIRROR B. ALL EXPOSED METAL PARTS (MODULE FRAMES, 6. ALL ELECTRICAL WORK SHALL COMPLY NTH THE (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 2011 NATIONAL ELECTRIC CODE. NEC NATIONAL ELECTRIC CODE UL LISTED LAY —IN LUGS LISTED FOR THE NIC NOT IN CONTRACT PURPOSE, POSTS SHALL BE MADE Sitred Plan ch NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED I OC ON CENTER RAIL. � P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE oik shall comply wit h the PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS fbilowing codes. 2006 I RC, 2006 PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. IECC & 20 , PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY NEAR S SUBANEL SHALL BE SIZED ACCORDING TO ART. CH SCHEDULE 250.166(B) & 690.47, SS STAINLESS STEEL SSD SEE STRUCTURAL DRAWINGS .. ,' � I ` �.� v STC STANDARD TESTING CONDITIONS Si TYP SOLAR WATER HEATER TYPICAL LION UNLESS OTHERWISE NOTED 0 UPS UNINTERRUPTIBLE POWER SUPPLY ", A; V Vp VOLT: VOLTAGE AT MAX POWER .. Ave i Ave Vac VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT if st ew REV BY DATE COMMENTS Ave ` A y Vy . ,. A i iD ° �r ter MAL _ THE A Is CONTAINED SHAM NOT s FOR THE pp L L (� j�}} ��}} `� �ry ('� ("� Ut lL 33 1 JlJ HEARD, JASON R17�I KLICH "er ENEM o� AE1 �x 7 sac., NOR SHALL IT as IN WH wav RESI Was: TRINA SOLAR TSM� 40PAO5 2941 EATON T .1 RV Array a , swarci Y. PART TO T rT ORGANIZ T is t�aac WI cT ` HAT RIDGE, CO $0214 TW SALE AND USE OF W RESPECTIVE CaTY EQW 7, m7HWT THE SC Yeti: 1 La — U sla e PACE 30s5 aeafww way San Mateo, CA 02 7: DATE P i s TYINC. PA T LEASE Pa POWER —ONE AURORA PVI-- 3.0— OUTD_,_ � 71 238 -�- 3 COVER SHEET R �/ 1 2 f 2.7201 r.m- CIly 24 Sofardty a��s>- Spa. -c (acs -zaa5) .�tsarcity.coan STAMPED AND SIGNED FOR S «.xw A, 3019 k dxm at Mu MMyi SITE PLAN N ��i 1 .. "�!' ■ ! ■ x s r � I 1pl yll ■I yl � } Y�� I� * � * IIII; JB-8021330 00 HEARD, JASON HEARD RESIDENCE MM INA SOLAR 2941 EATON ST 3.12 KW PV Array li 11 � WHEAT RIDGE, CO 80214 M • M p � VII Mild i 2 PACE NAME. 3055 Ckaivww Way CA 9440 Mt DAT 1N)"7m POWER-ONE #_4UR0RA_PVl_-3 4719) 238-8573 PV 2 2/27/2 O f T(650) 638-1028 i 1 1 (888)-SOLCnY(765-2489)wwwsolarcftyconI x s r � I 1pl yll ■I yl � } Y�� I� * � * IIII; (N) SIMPSON A34 CLIP W/ () Bd (0,131x3.5 ") NAILS (N) SPF#2 2x8 SISTER. NECESSARY SEE SECTION E FOR CONNECTION DETAILS RAFTE STAMPED AND SIGNED FOR STRUCTURAL ONLY mm SCALE; 1/4" = 1` S OLAR P, ATTACHED CLAM • BO LTS, AND J NUT SOL SOLAR ter. & i YE (E) COMP. SHINGL IM ■1 i i y Calvert Date: 0 0 . 1 0: 05:35 - 07'00 ' Y 1 • w ► INSTALLATION ORDER LO r IIIY K� ■ II R ESIDENCE LOCATION, AND DRILL PILOT-] H �� "'� a If, °w1 •' ! PLACE ■ LEVELING FO ♦ ! r IN STAL L o AX H 1` 1 A �� INA WASHE Y 1 • w ► .0 wom HEA R ESIDENCE �qii� ♦ �� INA 2941 EATON ST 3.12 KW PV Array y ■■ I sym, WHEAT RIDGE, CO 80214 Y PAG NAE 3055 QW(View Way SHUT. f" DAM T050) 638-1028 R(650) 638-1029 24" SPACING SCALE: 1/2" = V - SDW 22300 WOOD SCREWS • (E) RAFTER (N) END GROUP FASTENERS mmammm (E) 2x6 RAFTERS NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER BEAR DIRECTLY ON WALL BELOW OR CEILING JOIST IF PRESENT A X11 {E} 2x4 RAFTER 4" O.C, R (E) 2x4 CEILING Ml M AX S PA N: t '. t • SCAL 1/2" V S OLAR PA ATTACHE NTH MODULE CLAM • BO LTS, AND r NUT SOLARCITY SCAR RAIL & BOLT YETI (E) COMP. SHINGLE fit I I Yr y W loll t piol wil • =## ♦ :. # R` Y 1 +� INST ♦ iw Y 8 0 00 i �f J HE LOCAT l R A FTE R, MAR O i Y, }• *e :: a 3 ♦ f "'..I 1 F' !* LOCATION, AND DRILL PILOT r 1 M* . + 2 94 1 i 7 Arra ^ ®� =I I Ip1 II II 1 I VIII Il�llllf U �plNlll III �I� III � I I II IN SERT ECOFASTEN FLASHI d m"Tw SYM PLACE THE LEVELING FOOT. H IN rl i Nu I b� 6 t o � �� j SEA ��.. ' • loll t piol wil • =## ♦ :. # R` Y 1 +� i. NAM yyyyy,�� IIIAP 8 0 00 i �f J HE Y, }• *e :: a 3 ♦ f "'..I 1 F' !* r r 1 M* . + 2 94 1 i 7 Arra ®� . ..: d m"Tw SYM WHEAT RIDGE, CO 80214 ��.. SC Yeti: 1 PAM NAW cwarwew way KM DAX s w \'pf ♦. 1 ^' ■■ MI: IY 111 PO WER—ON 1" a A'�r # !.. STRUCTU 4 . (E) 24 RAFTERS 24" SPACING Ulw"Wwmqv, I Spam go MAW K "K-2, Mai O)Aw po, iw*i.-z Rw I I Aw #10, Too-Z *at mwmk VmP =240 VAC Imp=14.5 AAC 1 ) ml� ok lwm�2, t . ..... goc/qp fismPuk HEARD RESIDENCE 3.12 KW PV Array ' NAW: THREE LINE 21 mi zm Fft DAT. Pv 5 2/27/201 3055 CfeaMew Way San Mateo, CA 9+402 1':(650) 638-1028 F:(650) 636-1029 (888)-SOL-Cn'Y (765-2489) www,sotarcity,com ay (2) AWG PM PV OW. M" (I) Mg fl% S* Bwo Coppw Eoc TOC = MA VOC Vmp = 237,6 VDC ISC = 552 ADC Imp= &I ADC 4) (2)AWG #14 (1 )AW ilk SW Om UpW EOC 186,5 V6� VMP = 148.5 VDC isc'=&62' A'DC IMP= V ADC zm Fft DAT. Pv 5 2/27/201 3055 CfeaMew Way San Mateo, CA 9+402 1':(650) 638-1028 F:(650) 636-1029 (888)-SOL-Cn'Y (765-2489) www,sotarcity,com ay 1, Son ductor 9 690.8 m Conductor must hove 30 deg. C ampocity >= 125% of continuous current per Art 215,2(A)(1). M , Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16), b. Conductor must hove (offer corrections for conditions of use) >= continuous current per Table 310.15(B)(16). b. Conductor must hove (after corrections for conditions of use) >= continuous current per Table 310.15(8)(16). 7, Qgndqgjgr �izbg m Art ill (B)(1) a. Conductor must have 30 deg. C ompocity >= 125% of continuous current per Art 215.2(A)(1). ii . Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). 9 Total: Modules Voc 373 V Vmp; 29.7 V Esc:' 8.62 A Imp: 8.1 A Tvoc: 11936 V/deg C im M Total Env Pwr] 3480 j2723 PTC Total ST CIL 120 � - dery F dea C lcont * 1 25 = (Amps) i Branch Circuit 1)2e A 30 deg C am acct 'T 40 strings per branch I 10,771 Start ampacity 40 Temperature Berate (%=F) 0,71 0 , I Conduit fill derate I Derated amoacitv 28A ktt # 2.a do6ductdi Conductor IM lcont * 1 25 = (Amps) i Branch Circuit 1)2e A 30 deg C am acct 'T 40 strings per branch I 10,771 Start ampacity 40 Temperature Berate (%=F) 0,71 0 , I Conduit fill derate I Derated amoacitv 28A ktt 2.a do6ductdi Conductor IM lcont * 1 25 = (Amps) 1147 30 deg C am acct 'T 40 tcont= (Amps) 10,771 Start ampacity 40 Temperature Berate (%=F) 0,71 0 , I Conduit fill derate I Derated amoacitv 28A Im 11A toont * 1 25 OCP Size = MI ------- RM M M �� loont = (Amps) Start ampacity - ---------- Im i iiiii,l�1''111'1'1111'1111111�II!,� 1 111!11 EM MM PV Wire PV Wire Conductor I Conductor 2 610 WIMMM �19 A �31 1 way wire lengtil inverter current Art 690,8(AXI) 0 Z"!� EM EM R A iti-V 00M ku HEARD, JASON 2941 EATON ST WHEAT RIDGE, CO 80214 HEARD RESIDENCE 3.12 Array! PV Arro If! PAM DAM ELECTRICAL CALCULATIONS I PV 6 2/27/201 3055 Ckarview Way San Mateo, CA 9+102 T:(650)638-1028 F:(650)638-1029 (888) (765-2489) www.sdarc4,oxn 0 MITICI Label Location: (AC), (D), (LC) Per Code; CEC 690.8.A.3 & C 690.54, NEC Label Location: Per Code: CEC «"! 6W53 • -1 MR11g, HIMM11 mmm a e ocatio (AC) I 3055 aeaview Way 111 San Maeo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 .Itvl (888)-SOL-CITY (765-2489)www,sdarM.com VI MCM�c z. while structurally attaching solar panels to composition shingle roofs. This engineered connection uses Eco-Fasten's patented, IAPMO-certified "green fasten" technology to achieve a watertight seal, 6000 series aluminum offers superb structural and fatigue strength, which in conjunction with anodization offers excellent corrosion resistance even in coastal environments. Components A, 5/16" Lag Screw B, Stainless Steel + EPDM Sealing Washer C, Yeti (L-foot) D. Eco-Fasten Green Fasten Flashing \, \� \ � �: Olaticity, 6 a. solarcity, NA 0 c �,i ( c C) t L' e (; r -, t", 0 w 0 c 0 5 4 0 0 a 0 r) d w c; up 'o 240OPa (3�x=rteec'�, power outc;w % 0 - +3 7. H`igh .,)erfofrT under b 'ight cordifors Clovdy days, mornhgs and evenings Mcirufcicltgec' ( to 'Int eFratbrcA Guc.iJty card Env onrrerll NAcnagc"rrrc'q Syslcrr IS09001, IS014001 Ao MC4 H ccnrf�cto U "I" C'�' of w i t I -, h M taws RATURP, RAUNGS TSM-PCOS TSM-PA05 MAX�MUMRATMGS Nomind Operating Coll 45-C (t2'C) Operotionm Toorpertstum -40-+85 Temperature (NOCT) TOW -0,32VIC MaxsefrosFoseRafing 15A Mono 'MuW Solutions Peak Powet Watts hfiilrx (Wpl 235 240 2145 250 TSM-PCO5 Power Output 104""tance P"', 0/�Is 0"43 0/+3 0,43 Maximum Poww Valtages V- (V) 29,3 24 '7 30.2 30,3 Motrirrwrn Power Curfent-6w, (Al &03 8.10 833 8127 TSM-PA05 Open Cimuft VO V Poe fV) 37,2 37,3 3L5 37,6 Short CrrcOf CurreM bc tA) &as 61V2 8,68 &85 V [' R" (S L Li 'T I N Modute E-Vidency rl, 1*4 141 15.0 I5-3 E t,VIrOrssAW .a. Wadio,,, e OO: Wl,,,' M :fi (e 77777777 I I -W V4;JPA05 c A 01 F C P A OF sc NA 0 c �,i ( c C) t L' e (; r -, t", 0 w 0 c 0 5 4 0 0 a 0 r) d w c; up 'o 240OPa (3�x=rteec'�, power outc;w % 0 - +3 7. H`igh .,)erfofrT under b 'ight cordifors Clovdy days, mornhgs and evenings Mcirufcicltgec' ( to 'Int eFratbrcA Guc.iJty card Env onrrerll NAcnagc"rrrc'q Syslcrr IS09001, IS014001 Ao MC4 H ccnrf�cto U "I" C'�' of w i t I -, h M taws RATURP, RAUNGS MAX�MUMRATMGS Nomind Operating Coll 45-C (t2'C) Operotionm Toorpertstum -40-+85 Temperature (NOCT) TOW -0,32VIC MaxsefrosFoseRafing 15A WARkANI� gNeart' 'ele, tot"'eaa ucl.ezrc fw detailu PACKAGMG CONF tGURAT�Okt CAtMON, R' EADSAFE Y VD 701 .Ohc0noft'e' NOCT e 2TC, Vu"a spc'ed r mu- .O.V, 13% MEC,HAMCAL DAIA PVI-3.0L PVI-3,,6.- PVI Dim I - A# 44U IS MkW W AWH -W. C pWIUI at e>u tRC r.IlIt,wntK p.--bW Wh�, Kp+prod wO ptI.W M Wwh aMWI-q Bu CSA INTERNATIONAL. C'SA- C'22.2 No.107. I; 01 - General Use Power Supplies UL Std lido. 1'741 -Second Edition M Inverters, Converters, rs, C ontrollers and Interconnection System Equipment for Use 'With Distributed Fner y Resources (January 2 , 2010) MEMIMAIMMUMM 4 CITY OF WHEAT RIDGE .A Building Inspection Division (303 23 ) 4-5933 Inspection line -��(30��) 235-2855 Office - (303) 237-8929 Fax I x 4 No one available for inspection Time �pection require& Tes No I -- I - - I - - I MJIM-11% » « < • m Iwlxv Date: inspecto DO NOT REMQ� HIS _NOTICE <?■! :<^© �- © »x w f » «� » e ;! t : Date.- . < Plan # P#<## { \. # «»v. »® t» : «? « W~ P ? «y< Address: . . . . m «y- 2« M= . ^ \\2 /... . . ........ Phone: % < NU A� � INSPECTION RECORD OccuoancvlTvpe INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "'NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ►t41 r CITY OF WHEAT RIDGE Building Inspection Division J (303) 234 -5933 Inspection line (303) 235 -2855 Office " (303), 237 -8929 Fax INSPECTION NOTICE Inspection Type 01 0-i P&OF Job Address ?FYI �4 -7vAl T I Permit Number Jic5;ir,S Date: Inspector: DO NOT REMOVE THIS NOTICE r CITY OF WHEAT RIDGE Building Inspection Division ►// (303) 234 -5933 Inspection line %%% %% (303) 235 -2855 Office ,- (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type Job Address o ? 7X/ a it Permit Number .. • CITY OF WHEAT RIDGE - A/'/r Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office ` (303) 237 -8929 Fax INSPECTION NOTICE inspection Type Job Address s - 7° Permit Number w w t F ❑ No one available for inspection: Time AM /PM 41 City of Wheat Ridge l Residential Roofing PERMIT - 110265 PERMIT NO: 110265 ISSUED: 03/16/2011 JOB ADDRESS: 2941 EATON ST EXPIRES: 03/15/2012 DESCRIPTION: Reroof and redeck 15.49 sqs with 30 yr asphault shingles * ** CONTACTS * ** owner 719/238 -8573 Jason Herd sub 303/717 -7175 Travis Omiah 11 -0064 Beacon Restoration, LLC ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0811 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 7,278.54 FEES Permit Fee 172.60 Total Valuation .00 {� Use Tax 131.01 ** TOTAL ** 303.61 4- Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and /or its' accompanying approved plans and specifications. Signature of OWNER or LCONTRACTOR) (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. - 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject eld to fi i sp 'on. Signet ur o of Building Offical Date INSP TION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REOUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of R 7 �� h6 t ` midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application Date: Plan # Permit# PropertyAddness - ?_9 Lq I i D/j Si 2312 Property Owner (please print): �t Sin) (4. au Phone: :7 q 7 3 Mailing Address: (if different than property address) Address: City, State, Zip: Contractor: !�(' —IAN f� i 1�Z� i ) C n� �..i L Contractors City License #: j (— 8 p (, Phone: 7 12 ° 331° 7 Z 7 0 Sub_CohtYa�fnrs- Electrical: Plumbing: Mechanical: City License # City License # City License # DestCrt »ttonfiofworka Contract Value: $ �, z'� c� , sY W ttJ 5 �" Review Fee (due at time of submittal): Squares S BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I. hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances; rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions pr on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) CO (AUTHORIZED REPRESENTATIVE) �laf (OWNE R) R) (CONTRACTOR) PRINT NAME: { SIGNATURE: } ^- ^iil�ti (� �'�'-� DATE:.3 tZONING COMMENTS ' " ✓lv icj S Gv.i ,r �? .^Re r �' f�'re✓' ✓ z `lur ✓'' h � r�`-7�"1'S'ay f '�",r + �r7,��,. c a 1r./a,✓ -. a y + � �ai`� � ✓rl.�✓. s l '.. N � f^�".: r r' s s��K'". i a 5�r 2a� s r r ZOnln9 7 r i�r s Yrz� i '.. -"'f i.r s i'� ,.� rrr'�``l v' �'' r � x F - � ,s„^ -" n✓ � !v ��✓ .r's ' e; t .d ie N s �� -.- „✓ �� r „�. � � ,/ `� *�:.;� rr "' � F "2s ' ��� .Y`r'�� fr �YS,^r;�yf`�,� w a.i' �1��1 -�° �'i ^..ire rS ?. G ✓ ✓ v 5 y ,�✓ �i "" s ✓. ra �`�` qr'v, -' �+,mr� � � u; ! �i/'n ,,., i ' 42�,s,aw..�,Or .., �.7✓`.;�. .,r/s,,,. s.., .,>.,- .,,d.. ., . ✓l ..,,myl .,,,,�.vr rr,u zt.�t'�. fs���znt ;.Pi �> s;v^Sti 9 �„ 1 r��',�..m, ,,c%s „3i..�. � °': I ..,.��.r ;..✓ ...ri ""� .�5,../',, -Yr ,J�!r,z,.��va r' f . �..r,S..X.,.tl�� s J"' >�.,�"iul.,.,�„.� , s.����!,'..:F,r. TMENT p approved w /comments ❑ dlsaroyed CL no rrvlew re'ulre47 Bldg Valuation: COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 16099 Date: 8/21/2003 Property Owner: MICHAEL G. DAME Property Address: 2941 EATON ST Contractor License No. : Company: Phone: 445-1145 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for complia e with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ri e r i es, for work under this permit. DATE~ l/tv! 0.3 Total: $300.00 $30.55 $0.00 $6.00 $36.55 Construction Value: Permit Fee: Plan Review Fee: Use Tax: (OVVNER)(CQ~IHl~.eTOf'() SIGNED Use: 00l~~J) Description: RE-SIDE FRONT OF HOME (40') WI T-11 SIDING BUILDING DEPARTMENT USE ONLY iQg~n~; Approval: Zon ing : !:ll.ltlA~<<'mm;rnts;~ Approval: PufllTlil1C{lIQrl\sCo"~- ....!!!.1:li!,I~..,..,' ./l!!M._ Approval: Occupancy: Walls: SIC: Sq. Ft.: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: E)(piration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem, (5) Contractor shall notify the Building Inspector twenty.four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. {6~uance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the ~.~ ilding codes or any other ordinance, law, rule or regulation, Chief Buil clbr Please sign Terms and Conditions on reverse side of page. /~"a\ .Hf" "'/ ,- ~ C 1- \ 0 iv ,..., < \ \ ~^ c '--.li..Oti,.Q- COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH A VENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPLlCA TlON PAM~ Sr, Building Pennit Number: Date: Property Owner: Property Address: Contractor License No.: Company: #< ~f-I A-f7~ t7 _ E /'}"rtp Iv ~9tfl Phone: j'o:f _tl"".r-IIY'.s Phone: OW~ERlCO.'\"TRACTOR SICr"iATrRE OF l'."\DERSTA.'\Dl."\G A.'\D AGREB1[.'\T Construction Value:$ .5".,. "';:? Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ I ht:reby certify that the setback distances proposed by this permit application arc accurate, and do nOl violate applicable ordinances. rules or regulations of the City of\Vheat Ridge or covenants, e.ascmcnLS or restrictions of record; that all measuremenLS shown, and al1etations made aTC accur-dte; that I have read and agree 10 abide by all conditions printed on this application and that J assume full responsibility for compliance "..ith the Wheal Ridge Duilding Code (U.B.C) and all other applicable Wheat Ridge Or inances, for work under this permit DATE.;' ~O( {OWSER)(C"o:;;rp . <;:]9a,: SIGNED iOWSER}{COSTRACTOR): PRI~TED FR"'Jv .,- DATE IPP- DESCRIPTION: 'j?e -S/1?~- !-I(>-'k...C- ('(0') t.<./T-IISIPI.....s:-- BUILDING DEPARTMENT USE ONL Y SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMeNTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: i I) This pcmlil was issued in accordance with the provisions set forth in :your application and is subJecl 10 the laws of tllC SUIC of CokJrado and to thc Zonill~ Regulations and Building Codes of Wbeal Ridge, Colol1ldo or an)' other applicable ordinances ofmc Cily. (2) This pcnnit shall upire if(A) thc work authorized is nOl commenced within six!) (60) days from issuc dale or (D) tllC building authorized is susf>('lldcd or abandoned for a period of 120 days (3) If this pcrmil cxpires. a ncw pcmlil may be acquired for a fee orone~halrthe amount nomlally requircd. provided no chant!-es have been or will be made in the original plans and specifications and atI)' sllSpCnsioo or abandonm~nl has nOl excceded one (I) yeilr. If chilnt!-es have been or if suspension or ilb.andonmenl CACeed.s one (I) year. full fees shall be ~id (or a new permit (4) !'>o work of any manner shall be don~ that will change the natul1lJ flow of water causing a drainage probm. is) Conlnlctor shall notify the Building Inspeclor Iwen!)-four (24) ho~ in ad\.ance for all inspections and shall recei\.c \\'rillen approval Oil inspection card before proceeding \\'ilh successi\~ phases of th~ job (6) The issuance of.. permit or the awro\.al of dnIwings and sp<<iflCations shall DOl be corn.rruc:d to be a pennil for. nor an approval of. any violation of the provisions of the building codes or any other ordinance, Law, rule or regulation Chief Building Inspector BUILDING DEPARTMENT (303) 235-2855 CITY OF WHEAT RIDGE * * Correction Notice Job Located at ~ I ~ / ~ ;JY' I have this day inspected this structure and these premises and have found the following violations of City and/or State laws gov- erning same: .........."d f~~ ..-- r~ You are hereby notified to correct the foregoing violations. When corrections have been made, call for inspection. Date ?-. -F - i 7 ~'/A' .e; Inspector lor Building Dept. DO NOT REMOVE THIS TAG FORM WR6-22 ID'EPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 5496 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 7/22/97 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 +- Property Owner: Property Address: 2941 EATON ST Contractor License No.: 18141 Company: Denver Burglar Alarm Co. Phone: 445-1145 Phone: 292 2222 +- OiNNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ; I I hereby certify that the setback distances proposed by this permit application are accurate, a~d del not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or c vemmts, easements or restrictions of record; that all measurements shown, and allegations m de are accurate; that I have read and agree to abide by all conditions printed on this aftPlic;~tion, and that I assume full responsibility for compliance with the Wheat Ridge Building Crde (V.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (qWNER)(CONTRACTOR) SIGNED Q~r- '::7/3 A ~DATE/fL2/:r-? i ~ V. , ;Description: INSTALL & MONITOR SECURITY ALARM SYSTEM WI 1ST ALERT COMMUNICATOR I , Construction Value: Permit Fee: Total: $295.00 $25.00 $0.00 $25.00 Use Tax: BUILDING DEPARTMENT USE ONLY 11_.._ Approval: Zoning: ._.m__ Approval: SIC: Sq. Ft. : 1I111~ Approval: Occupancy: Walls: Roof: Stories: Residential Units: +- ~Iectrical License No : dompany : i I Plumbing License No : Company: Mechanical License No : Company: ~xplration Date: Approval: .-- .- (1) (2) (3) Expiration Date: Approval: II _IIIlIIIDJ_. Expiration Date: Approval: IIl~!DIfIBBm_ This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspenSion or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that Will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the Job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions ~ bUildr9 cOdeS;r any other,qrdinance, I~W, rule or regulation. lc r //&.J C? I f Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNINu ANU Ut:Vt:L.Ut"IVIt:N I BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 tlUIIUlIlg r-enrllL ''1UIIIU." . Date: 7/21/97 Property Owner: Property Address: Contractor License No. : Company: Bristlecone Ridge 294l Eaton Street" ih!alio~~ 18141 Phone: Bf445-1145 / Denver Burglar Alarm C'nnp>FlY't Inc. Phone: 292-2222 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value; Permit Fee; C-{)l084 Use Tax; $295.00 $ 25.00 I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants. easements or restrictions of record: that all measurementg shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application. and that I assume full responSibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit BROCE RYAN Description: INSTALL AND I'lJNITOR SFnlRITY ALARM SYS'.l'FJt WITH A FIRS.r ALERT 145C DIGITAL c:x>>MlNICATOR_ BUILDING DEPAHTMENT USE ONLY DATE 7/21/97 Total: $ 25.00 (OWNER)(CONTRACTOR) SIGNED "J.! !~~J.I)rm. \'.1' Approval: Zoning: JWII(lm.lJ1~UUnfitl\~1l Approval; M~J.lll;.W(jjlilll.Omnlllllllttl;: Approval: Occupancy: Walls: Roof: Stories: Residential Units; Electrrcal License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: .JJ . PlallsR.equlred::'.' I Expiration Date: Approval: d Plalls. Required .I Expiration Date: Approval; ~ !p!l\nsRlIqulre'!li';;0J (11 (2) (3) This perrnll wa!llssued in accordance wllh the provISIons set forth in yopur application and is SUbject to the laws of the State of Colorado and to 1M Zoning Regulations and Building Code of \^/heat Ridge, Colorado or any other applicable ordimmces of the City. This pP.Hllil sl1all e)(plre II (A) the work authorized is not commenced within sixly 1601 days from issue date or (8) the building authorized is suspended Of abandoned for a penod of 120 d3Y!l If this pel mit expires, a new pernl!t may be acquired for a fee of one-half the amolllll normally required, provided no changes have been or will be mlde in lhe origrnal plans and specrficalrons and any suspension or abandonment has not ellceeded one (t) year. " changes Ire made or I' suspension or abandonment e)(ceeds one (1) year, full fees shall be paid for a new permit No work. or any manner shall be done that will change the natural flow of waler causing a drainage problem Contractor shall nOhfy the BUildIng Inspeclor twenty.lour (24) hours In advance for all inspections and shall receive wnlten approval on inspec:tion card belore proceedllng wrlh successrve phases of 'he job The issuance of 11 perm.t or the approval 0' drawings and specifications shall not be conslrued to be a permit for, nor an approval of. any violation of the ptOVtSions of the burlding codes or any other ordrnance, law. rule or regulation. (4) (5) 16) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234.5933 24 HOURS PHlOR TO INSPECTION . .,.J. i.I.!)1 " "'~""'""'""~'.""""''''."..'' .'''''''''''''' """'"'P''''''''''''I'1''''''''''"''-''''''''''"'''''~<'."'''"",~,x,.,;,~ "<.'.' '",' ""~",,, ?'7..'''.'''."....''''.".,IlI.~''''''~...,.'"''''~'''''".~.. DEPARTMENT O.F PLANNING AND DEVELOPMENT Building Permit Number: 4545 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 2/5/97 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: 2941 EATON ST Contractor License No.: 17044 Company: A & P Heating Co., Inc. Phone: Phone :534 4841 ERlCONTAACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Description: REPLACE FURNACE DATE l-S-~ Total: $2,800.00 $75.50 $0.00 $33.60 $109.10 Construction Value: Permit Fee: Plan Review Fee : Use Tax: I ereby certify that the setbaCk <listances proposed by this penntt application are accunate, a do not violate lIDIIIIcable ordinances, rules or regulations of the Ctty of Wheat Ridge or venants, easemenls or res\riClions of record; that all measurements shown, and allegations m. are accUfllte; that I have read end ""ree 10 abide by all condttlons printed on this Iicllllon, and that I assume full responslb' for complian wtth the Wheat Ridge Building (U.B.C.) and all other applicable Wh at ge ordina 10 wall< under this penntt. ER)(CONTAACTOR) SIGNED BUILDING DEPARTMENT USE ONLY SIC: Sq. Ft.: Approval: Occupancy : Walls: Roof: Stories: Residential Units : ectrical License No : ompany : Plumbing License No : Company: Mechanical License No : Company: Expiration Dale: Approval: . Expiration Date: Approval: . (1) This pennit was Isoued in _ with the I'lO"iSI<>nS set ror1h in yopur appIk:ation and Is subled In the laws 01 the Sf8le 01 CoIolado and In the ZonIng BeguIotioI1s and Build"'" COCIe 01_ RIcIoO, Colorado or any other 00DII0abIe ordinances 01 the City. (Z) 11111 pol111il. Sh!lfllllqlil8 ff (A) the work authorIZed Is not ccnvnenced _ sixty (60) days from issue _ or (B) the buildlng _Is suopended or abandoned !of a period "'=20 . (3) If this pol111il ""pires, a new may be acquired fOr s ree 01 ona-halfthe amount normally required, orovIdod no ~ heve been orwlll be mode In the ortgIilaf plana and 1p8C1ifi a and any 8U8P8n81on or abandonment has not exceeded one <1> yeer. "tf changes are made or Ifsuspenaion or abendonment ...- one (1) year, run rees sh8It be paid fOr a new ponnIt. (4) No wofl< 01 any manner shall be done that will change the natural flow 01_ causing s drainage pIObIem. (5) =r.:.~ s:n~lobtwenty-rour (24) heu," In sdvance fOr a1llnspecllons and shall__ approval on Inspection CIIId before (6) isSuInOe 010. pol111il or the spprovaI ofdrawlngs and spocIticaticns shall not be ccnstnJod In be a pol111il fOr, nor an spprovaI 01, any vIoIaIion 01 the provisions the butldlngcodes or any other ordinance. law, role or regulation. ief Buildtng Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECnON - DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215. Property Owner: Property Address: Contractor License No. : Company: fl., ):e. 2..cr'-j ( '- fos'i.e r /-::: ..i /)/1 -_. ,--<- 5'-1 Phone: A . -., - r . I He,,"! I''') Co Phone: Fez, Lj-'-! ,:>-if OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: .2.,1 '2. (/,) - I hereby certify that the setback distances proposed by this pennit application are accurate, and d(> not violate applicable ordinances, rules or regulations oftMe City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this appJic:ation, and that I assume full responsibility for compliance with the Wheat Ridge Building Code {U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ;0 '~J2H ~. ~ DATE I ,(~ },J (l;~::,Ji~^0 Description: lo;;i,.,II ~'.,,:o.~d ""il ~€'",--li"'J c::.'Y5---!~" BUILDING DEPARTMENT USE ONLY Total: ~mfi'MGpmmenl$;3 Approval: Zoning: BIl1R1~mm"J1ti1l1 Approval: ~D'6!~J~mm.'n~ Approval: Occupancy: Walls: SIC: Sq. Ft.: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: . ,I ~ ~... . . j . It Expiration Date: Approval : . Expiration Date: Approval: '.. ur.'IlI'.' . ,. J;lil,! , ."W '. . (1) (2) (3) This permit was issued In accordance with the provisions set forth in yapur application and Is subject to the laws of the State of Colorado and to the Zoning Regulations and Buildin~ Code of Wheat Rid~e. Colorado or any other applicable ordinances of the City. This permit shall expire If (A) the work authonzed is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. It this permit expires, a new permit may be acquired for a fee of one-half the amount normally required. provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty.four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceed ling with successive phases of thel'ob. The Issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BYTHE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION >t11""",,,"'(""W9"""""'if'J:f'l'~IlJl~~~~"~j 1II!1~~"'i'!\flI;,!j\\j!!ll",I!'I!F'_.j~,-"""~j~~lIl11l'ff~,lli':.'I,!l\Il,~_"'.~' DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 4517 " BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 1/28/97 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - Property Owner: Property Address: 2941 EATON ST Contractor License No.: 18980 Company: Electrical Services, Inc. Phone: 979-1733 Phone: 6992810 OWNIERlCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax : (OWNIER)(CONTRACTOR) SIGNED DATE Total: $850.00 $45.00 $0.00 $10.20 $55.20 I hereby certify that the setback distances proposed by this penntt application are accurate, and dc, not violate applicable ordinances, rules or regulations of the Ctty of Wheat Ridge or COVenlilnts, easements or restrictions of record; that all measurements shown, and allegations made ;ore accurate: that I have read and agree to abide by all condttlons printed on this appliclItion, and that I assume full responsibility for compliance wtth the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for woll< under this penntt. Description : SERVICE UPGRADE TO 100 AMPS, FURNACE CIRCUIT BUILDING DEPARTMENT USE ONLY SIC: Sq. Ft.: Approval: Zoning: Approval: Approval: Occupancy : Walls: Roof: Stories: Residential Units : Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval : .1 Expiration Date : Approval : . Expiration Date: Approval: . - (1) This pennltwas Issued in accordance with the provisions set forth in yopur appl\catlon and is subiect to the laws of the State of Colorado and to the Zoning Reg'ulatlons and Building Code of 'Nheat Ri~e, Colorado or any other applicable ordinances of the City. (2) This penntt shall expire If (A) the work authonzed is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 day's, (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required. provided no changes have been or will be made In the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid fOr a new permit. ~ (4.) No work of any manner shall be done that will change the natural now of water causing a drainage problem. () Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceedllng with successive phases of the job. (6) ille issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for. nor an approval of, any violation of the provisions of the building codes or a yother ordinance, taw, rule or regulation. Chief Building nsp THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT - BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215. Building Permit Number: Date: Property Owner: Property Address: Contractor License No. : Company: (Vii (Ge, Po5 / e ^- j1'-t1 t/'c47cvsT i f/i ED ~LGc7/liea.J:. ~1'-i/1C65 &L~ Phone: 9 7 Cj - /7 ;, 3 IV" Phone: 69'1- ~ ~ / b OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: 'ii'S?J,~ <fLOD J hereby certify that the setback distances proposed by this permit application are accurate, and d() not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this applic:ation, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable ~lJidge o1Lnces. ~or work under this permit. JOlA'N~)(CONTRACTOR) SIGNED~ {l ~ DATEjjd7 .. S<?(Z.VIC6 ~6/,,A.clf: (cc,4. l" Description: r. / f,-<tz.'LhtICr:! ~fl1., BUILDING DEPARTMENT USE ONLY / IO.l.D Total:' 5'5-, 2.D ~fI1~.QID!!l!!"~~ Approval: Zoning: IDiI!lllillmJj)mm~mtft Approval: eep.l~Pl~C9mm!!I!~ Approval: Occupancy: Walls: SIC: Sq. Fl.: If~~~:ID Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: 81 .. .~I ;_, ~ Expiration Date: Approval: . IP.lmmRJJIIJI~ Expiration Date: Approval: . J- ~"'-II .0i (4) (5) (6) This permit was issued in accordance with the provisions set forth in yapur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Rid~e, Colorado or any other applicable ordinances of the City. This permit shall expire If (A) the work authonzed is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the nalural flow of water causing a drainage problem. Contractor shalt notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the/"Ob. The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (1) (2) (3) Chief Building Inspector For Mayor THIS PERMITVAUD ONLY WHEN SIGNED BYTHE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION