Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2876 Gray Street
From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Solar PV Installation Date: Friday, May 15, 2020 9:57:02 AM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 2867 Gray St Property Owner Name Jason Cartwright Property Owner Phone 303-385-7603 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" jasoncartwrig8t@gmail.com Electronic Payment Form - Revised 5-1-20 Fillable 202005011620013849.Ddf CONTRACTOR INFORMATION Contractor Business BRS Field Ops, LLC Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the 180271 City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK Scope of Work KW # of Panels Location of Panels Structural required Upload engineer letter or pages on 8 1/2" x 11" only 385-482-0045 permitting.department@blueravensolar.com permitting.department@blueravensolar.com Revised layout for permit #202000848 4.48 14 house roof No Jason Cartwriaht Letter SS.Ddf Solar Installation Plan As -Built Permit Pack Jason Cartwriaht.0df Set on 11'x17" only. Project Value (contract $11,283.12 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Baylee Ence Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. GENERAL NOTES CODES AND STANDARDS 1. ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE (NEC), 2015 INTERNATIONAL BUILDING CODE (IBC), 2015 INTERNATIONAL RESIDENTIAL CODE (IRC), 2015 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES. 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. SITE NOTES / OSHA REGULATION 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. 5. NO. OF SHINGLES LAYERS -1 SOLAR CONTRACTOR 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM. 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT AVAILABLE. 9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, DC COMBINERS, DC -TO -DC CONVERTERS, SOURCE CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (B). 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. 11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. EQUIPMENT LOCATIONS 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]. 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY [NEC 690.31 (A) -(B)] AND [NEC TABLE 310.15 (B)]. 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT TO THE UTILITY AC DISCONNECT, OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. .'A• City of '� W heat idle COMMUNI"IY 13EVELUPMENT APPROVED Reviewed for Code Compliance z � W, iJ �� -,z41 .51.2-02-0 ZaZa Plans Examiner Date Validity of permit: The Issuance of o permit or opprovat of plums spec4k;ottons and compumhons shall not be a permit fru, or an approval of, any viotobon to any of the provisions of the budding code or of ajW City ordinances. Piermlts presuming to givr outhority to vio aw or cancel the promims of the awAft COda or othtr on*nonoes of the Oty shaN not be v0d. AERIAL VIEW t - t r DESIGN CRITERIA WIND SPEED- 120 MPH GROUND SNOW LOAD- 30 PSF WIND EXPOSURE FACTOR- C SEISMIC DESIGN CATEGORY- B SCOPE OF WORK OEM r 4 40 E� t �r t t _ * A i � I r 39 lid - i SITE SPECIFICATIONS OCCUPANCY -R3 CONSTRUCTION - V -B ZONING- RESIDENTIAL INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM 4.48 kW DC PHOTOVOLTAIC SOLAR ARRAY ROO oma S 91e MO ULES. (14) Trinasolar 320 TSM-DD06M.05(II) INVERTER(S)- Enphase IQ7 Microinverters----- R&CKING- Pnirac SFIM Infinity ,\ Approval Notes: 1) P/V array system to have grounding system installed per Part III of Article 250 per 2017 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2017 NEC Article 250.53(A)(3). 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(6) SHEET INDEX PV1 - COVER SHEET PV2 - PROPERTY PLAN PV3 - SITE PLAN PV4 - EQUIPMENT & ATTACHMENT DETAIL PV5 - ELECTRICAL SINGLE LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS & ELECTRICAL NOTES PV7 - MAIN BREAKER DERATE CALCS. (IF NEEDED) PV8 - LABELS & LOCATIONS PV9 - CUSTOM DIRECTORY PLACARD (IF NEEDED - NEC 690.56(B)) Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 l DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME COVER SHEET PAGE NUMBER REVISION PV1 I B Q C CD CD O z ca O }' O N_ <0 OU z}, 0 ?j fn CU 0 UC) G w U) o � ti (N >a > C) DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME COVER SHEET PAGE NUMBER REVISION PV1 I B DC SYSTEM SIZE: 4.48 kW DC (14) Trinasolar 320 TSM-DD06M.05(II) 1 A Enphase IQ7 Microinverters ----- INVERTER IA, W 2 O 2 LL O H Z O Of LL m 0 r 00 00 N i Fr_r:rI INV INVERTER &DC DISCONNECT SUB (E) SUBPANEL LC (N) LOAD CENTER 171 C AC DISCONNECT ❑M UTILITY METER MSP MAIN SERVICE PANEL JB JUNCTION BOX TS TRANSFER SWITCH C❑ COMBINER BOX/AGGREGATOR PV PV REVENUE METER ® FIRE SETBACK EMT CONDUIT RUN (TO BE DETERMINED IN FIELD) PV WIRE STRING PROPERTY LINE BLUE RAVEN 1403 N RESEARCH WAV, BUILDING J OREM, UT 84097 800-377-4480 W W W.BLUERAV E NSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 SCALE: 1/16" = V-0" CONTRACTOR: BRS FIELD OPS 385.498.6700 DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME PROPERTY PLAN PAGE NUMBER REVISION PV2 B N O 00 O Z O o H o O N ai �_ LL Z_ U m CD Fy Bea H W(n o � r` W N N DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME PROPERTY PLAN PAGE NUMBER REVISION PV2 B UNDERGROUND SKYLIGHT MP4 # OF MODULES: 3 AZIMUTH:180° PITCH:16° TSRF:67% AREA: 230 SQ. FT CE LINE DC SYSTEM SIZE: 4.48 kW DC (14) Trinasolar 320 TSM-DD06M.05(II) Enphase IQ7 Microinverters ----- INVERTER T 0 11 Mall M 10 MP3 # OF MODULES: 2 AZIMUTH:90° PITCH:23° TSRF:56% AREA: 181.59 SQ. FT 3 MP2 # OF MODULES: 6 AZIMUTH:90° PI TCH:23° TSRF:75% AREA: 220.72 SQ. FT 5C 5C riC 0/ 0 U ra 5C IqC 5C IqC MP1 # OF MODULES: 6 AZIMUTH:180° PITCH:23° TSRF:76% AREA: 171.92 SQ. FT w O LL O H Z O w - w i Fr_r:rI INV INVERTER &DC DISCONNECT SUB (E) SUBPANEL 171 C (N) LOAD CENTER AC AC DISCONNECT ❑M UTILITY METER MSP MAIN SERVICE PANEL JB JUNCTION BOX TS TRANSFER SWITCH C❑ COMBINER BOX/AGGREGATOR PV PV REVENUE METER ® FIRE SETBACK EMT CONDUIT RUN (TO BE DETERMINED IN FIELD) PV WIRE STRING PROPERTY LINE BLUE RAVEN 1403 N RESEARCH WAV, BUILDING J OREM. UT 84097 800-377-4480 W W W.BLUERA V ENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 SCALE: 1/8" = T-0" CONTRACTOR: BRS FIELD OPS 52051 DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME SITE PLAN PAGENUMBER REVISION PV3 B v N O 00 O Z m O o H o O N ai -0 LL U z_ O �_ w o � W) m (O w m t DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME SITE PLAN PAGENUMBER REVISION PV3 B PV ARRAY INFORMATION PV MODULE COUNT: 14 MODULES # OF ATTACHMENT POINTS: 32 ARRAY AREA: Module Count x 17.51ft2 = 245.1ft2 ROOF AREA: 1898.9ft2 % OF ARRAY/ROOF: 12.9% ARRAY WEIGHT: Module Count x 50lbs = 700.Olbs DISTRIBUTED LOAD: Array Weight + Array Area = 2.86 IbsI POINT LOAD: Array Weight + Attachments = 21.9lbs/attachment Unirac SFM Infinity UNIRAC TRIMRAIL Unirac SFM Infinity Tnnasolar 320 TSM-DD06M.05(II) � PV MODULE O Tnnasolar 320 TSM-DD06M.05(II) 0 PV MODULE z (E) ROOF H p MEMBRANE U) _ I] 0 ® 2.511UNIRAC SLIDERS AND rM TRIMRAIL ROOF ATTACHMENTS O6 m m 0 2.5" MIN. EMBED. FLASHING 0M o Q UNIRAC SLIDERS w 5/16" STAINLESS STEEL LAG BOLT p WITH 2-1/2" MIN. EMBEDMENT W AND FLAT WASHER (7 (E) BUILDING (O ONO STRUCTURE Unirac SFM Infinity IQ PV MODULE (BEHIND TRIM RAIL) 1 -11 7 72" MAX. MAX. SEA Infinity RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH Unirac SFM Infinity FRAME SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER. �H1 rac SFM Infinity TRIM RAIL PORTRAIT LANDSCAPE ARRAY DETAIL, FRONT VIEW Scale: 3/8" = V-0" PORTRAIT G PV4 LANDSCAPE :AY DETAIL, SIDE VIEW ROOF TYPE: Comp Shingle ROOF FRAMING TYPE: Rafter RAFTER OR TOP CHORD(TRUSS) 2x6 @ 24"O.C. CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x6 @ 16"O.C. Scale: 3/8" = V-0" BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 W WW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 VVV� ILL O0 Tnnasolar 320 TSM-DD06M.05(II) z PV MODULE V) O 09 (E) ROOF 2.5" MEMBRANE LU e J - O 0M o U UNIRAC SLIDERS 2.5" MIN. EMBED. O H FLASHING W �_ 5/16" STAINLESS STEEL LAG BOLT (O ONO WITH 2-1/2" MIN. EMBEDMENT = AND FLAT WASHER (E) BUILDING STRUCTURE IQ PV MODULE (BEHIND TRIM RAIL) 1 -11 7 72" MAX. MAX. SEA Infinity RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH Unirac SFM Infinity FRAME SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER. �H1 rac SFM Infinity TRIM RAIL PORTRAIT LANDSCAPE ARRAY DETAIL, FRONT VIEW Scale: 3/8" = V-0" PORTRAIT G PV4 LANDSCAPE :AY DETAIL, SIDE VIEW ROOF TYPE: Comp Shingle ROOF FRAMING TYPE: Rafter RAFTER OR TOP CHORD(TRUSS) 2x6 @ 24"O.C. CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x6 @ 16"O.C. Scale: 3/8" = V-0" BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 W WW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 HE BY DIN ENGINEERING May 14, 2020 NUMBER 71843692 T NAME EQUIP. DETAIL NUMBER REVISION I B V N O W 0 Z O o H 0 O N ai LL U Z �_ W o � 0 (O ONO t HE BY DIN ENGINEERING May 14, 2020 NUMBER 71843692 T NAME EQUIP. DETAIL NUMBER REVISION I B (1) 10 AWG THHN/THWN-2, CU., BLACK (L1) 14.0 A AC (1) 12 - 2 OF -B W/G, THHN/THWN-2, SOLID CU. MAX 14.0 A A( 15 (1) 10 AWG THHN/THWN-2, CU., RED (L2) 240 V AC 3 240 V A( (1) 10 AWG THHN/THWN-2, CU., WHITE (N) (1) 10 AWG THHN/THWN-2, CU., GREEN (EGC) (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT EXTERIOR 1. ALL CONDUIT TO BE RAN AT LEAST 7/8" ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. 2. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. 3. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. (E)200A MAIN SERVICE PANEL (E)150A / 2P MAIN BREAKER PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER (E) GROUNDING ELECTRODE (S) Approval Notes: 1) P/V array system to have grounding system installed per Part III of Article 250 per 2017 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2017 NEC Article 250.53(A)(3). 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(6) UTILITY PV PRODUCTION METER 200A LEVER BYPASS METER SOCKET INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12]. PV AC DISCONNECT NON-FUSED LOCKABLE, VISIBLE OPEN 30A, 240V, 2 -POLE ENPHASE COMBINER BOX WILL BE ACCESSIBLE TO UTILITY COMPANY 24/7 (1) 12 - 2 OF -B (or NM) W/G, THHN/THWN-2, SC 2 OR 12-2TC-ER,THHN/THWN-2, CU., 90C Enphase IQ Combiner 3 X -I Q -AM 1-240-3 (SOLAR LOADS ONLY) N PV Production meter notes: 1. The self-contained metering will be in compliance with the most recent revision of the Xcel Energy Standard; specifically Section 4.11. 2. The PV production meter will be required to have the PV generation wired to the line side terminals (top of meter block). 3. The meter socket for the PV production meter shall be marked with a stamped brass, aluminum, or stainless steel tag, indicating the address including the unit, typically "PV PROD" in accordance with the requirements for "Meter Identification" in Section 4.14.4 of the Xcel Energy Standard. 4. The PV production meter shall be located within ten (10) feet of the existing utility meter. If there is any reason this cannot be accomplished, a site plan showing proposed equipment locations shall be submitted for review. The local meter shop must approve the site plan for application approval; site meetings can be arranged upon request. NOTE TO INSTALLER: The current Placard that we require at the utility meter and AC Disconnect is a yellow with black lettering MAX 14.0 A 240 V INTERIOR �(1) 12-2 TC-ER,THHN/THWN-2, CU. MAX 14.0 A AC q (1) 6 AWG BARE, CU (EGC) 240 V AC EXTERIOR (14) Trinasolar 320 TSM-DD06M.05(II) "JUNCTION BOX(S) UL 1703 COMPLIANT FOR WIRE SPLICING (14) Enphase IQ7 Microinverters MICRO ONLY - OPTIONAL IF INVERTERS Q -CABLE (TC -ER) OR UL 1741 COMPLIANT OF -B USED FOR 7 MODULES MAX FOR ALL SUB -BRANCH ENTIRE HOMERUN CIRCUIT(S) TO COMPLY WITH VRIS CALCS JUNCTION BOX JUNCTION BOX (1) CIRCUIT L1 L1 N N OF 14 MODULES L2 L2 G G l�v�7 As Noted -- — - — ____T Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Z-11.1.�,� FICERTIFIED I PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 IN (E)150A / 2P (E)LOADS (N)20A/2P L' L: NF N e 120/240 VAC O `1 60HZ 1 PHASE 00 TO UTILITY O J GRID G PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER (E) GROUNDING ELECTRODE (S) Approval Notes: 1) P/V array system to have grounding system installed per Part III of Article 250 per 2017 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2017 NEC Article 250.53(A)(3). 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(6) UTILITY PV PRODUCTION METER 200A LEVER BYPASS METER SOCKET INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12]. PV AC DISCONNECT NON-FUSED LOCKABLE, VISIBLE OPEN 30A, 240V, 2 -POLE ENPHASE COMBINER BOX WILL BE ACCESSIBLE TO UTILITY COMPANY 24/7 (1) 12 - 2 OF -B (or NM) W/G, THHN/THWN-2, SC 2 OR 12-2TC-ER,THHN/THWN-2, CU., 90C Enphase IQ Combiner 3 X -I Q -AM 1-240-3 (SOLAR LOADS ONLY) N PV Production meter notes: 1. The self-contained metering will be in compliance with the most recent revision of the Xcel Energy Standard; specifically Section 4.11. 2. The PV production meter will be required to have the PV generation wired to the line side terminals (top of meter block). 3. The meter socket for the PV production meter shall be marked with a stamped brass, aluminum, or stainless steel tag, indicating the address including the unit, typically "PV PROD" in accordance with the requirements for "Meter Identification" in Section 4.14.4 of the Xcel Energy Standard. 4. The PV production meter shall be located within ten (10) feet of the existing utility meter. If there is any reason this cannot be accomplished, a site plan showing proposed equipment locations shall be submitted for review. The local meter shop must approve the site plan for application approval; site meetings can be arranged upon request. NOTE TO INSTALLER: The current Placard that we require at the utility meter and AC Disconnect is a yellow with black lettering MAX 14.0 A 240 V INTERIOR �(1) 12-2 TC-ER,THHN/THWN-2, CU. MAX 14.0 A AC q (1) 6 AWG BARE, CU (EGC) 240 V AC EXTERIOR (14) Trinasolar 320 TSM-DD06M.05(II) "JUNCTION BOX(S) UL 1703 COMPLIANT FOR WIRE SPLICING (14) Enphase IQ7 Microinverters MICRO ONLY - OPTIONAL IF INVERTERS Q -CABLE (TC -ER) OR UL 1741 COMPLIANT OF -B USED FOR 7 MODULES MAX FOR ALL SUB -BRANCH ENTIRE HOMERUN CIRCUIT(S) TO COMPLY WITH VRIS CALCS JUNCTION BOX JUNCTION BOX (1) CIRCUIT L1 L1 N N OF 14 MODULES L2 L2 G G l�v�7 As Noted -- — - — ____T Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Z-11.1.�,� FICERTIFIED I PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 IN DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME ELEC. 3 LINE DIAG PAGE NUMBER REVISION PV5 B N O `1 00 00 O ZCU O}' O N_ LL U Cn CU U 0 U) W U) O ti N N lid DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME ELEC. 3 LINE DIAG PAGE NUMBER REVISION PV5 B MU DULL S)PELI FILA I IUN�) I n nasolar 31U I �)M-UUUbM.U5(I I) RATED POWER (STC) 320 W MODULE VOC 40.3 V DC MODULE VMP 33.4 V DC MODULE IMP 9.58 A DC MODULE ISC 10.2 A DC VOC CORRECTION -0.26 %/°C VMP CORRECTION -0.36 %/°C SERIES FUSE RATING 20 A DC ADJ. MODULE VOC @ ASHRAE LOW TEMP 44.4 V DC ADJ. MODULE VMP @ ASHRAE 2% AVG. HIGH TEMP 28.6 V DC MICROINVERTER SPECIFICATIONS Enphase IQ7 Microi nVerters POWER PO I NT TRACKI NG (MP PT) MIN/MAX 22 - 48 V DC MAXIMUM INPUT VOLTAGE 48 V DC MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC MAXIMUM USABLE DC INPUT POWER 350 W MAXIMUM OUTPUT CURRENT 1 A AC AC OVERCURRENT PROTECTION 20 A MAXIMUM OUTPUT POWER 240 W CEC WEIGHTED EFFICIENCY 97% AC: PHU IUVULA IIC: MUUULE MARKING; (NEC: b9U.52) N OMI NAL OP ERATI NG AC VOLTAGE 240 V AC NOMI NAL OPERATI NG AC FREQUENCY 47 - 68 HZ AC MAXIMUM AC POWER 240 VA AC MAXIMUM AC CURRENT 1.0 A AC MAXIMUM OCPD RATING FOR AC MODULE 20 A AC DESIGN LOCATION AND TEMPERATURES TEMPERATURE DATA SOURCE ASHRAE 2% AVG. HIGH TEMP STATE Colorado CITY Wheat Ridge WEATHER STATION SALISBURY WICOMICO CO AP ASHRAE EXTREME LOW TEMP (°C) -14 ASHRAE 2% AVG. HIGH TEMP (°C) 33 ��'�� � � ►►► I � � xif � :l [�1�[ �� � xiI I � [�l,� r ISI r • ��i11:zi �iI I :i��I t :J <eJ tiI I :i �i1 I :��i1 fi:� NUMBER OF MODULES PER MPPT DC POWER RATING PER CIRCUIT (STC) TOTAL MODULE NUMBER STC RATING OF ARRAY AC CURRENT @ MAX POWER POINT (IMP) MAX. CURRENT (IMP X 1.25) OCPD CURRENT RATING PER CIRCUIT MAX. COMB. ARRAY AC CURRENT (IMP) MAX. ARRAY AC POWER 14 4480 COND. VRISE(V) VEND(V; %VRISE IQ7-7 VRISE SEC. 1(MICRO TO JBOX) 25.2 12 Cu. 14 MODULES 4480W DC 14.0 17.5 20 VRISE SEC. 2 (J BOX TO COMBINER BOX) 60 12 Cu. 3.39 243.39 14.0 F 3360W AC AC VOLTAGE RISE CALCULATIONS DIST (FT) COND. VRISE(V) VEND(V; %VRISE IQ7-7 VRISE SEC. 1(MICRO TO JBOX) 25.2 12 Cu. 0.71 240.71 0.30% VRISE SEC. 2 (J BOX TO COMBINER BOX) 60 12 Cu. 3.39 243.39 1.41% VRISE SEC. 3 (COMBINER BOX TO POI) 10 10 Cu. 0.36 240.36 0.15% TOTALVRISE 17.5 JUNCTION BOX TO 4.46 244.46 1.86% PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL (NEC 690.54) 4C OUTPUT CURRENT 14.0 A AC NOMINAL AC VOLTAGE 240 V AC GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690-47] AND [NEC 250-50] THROUGH [NEC 250-60] SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64C.]. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED. 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO [NEC 690.45] AND BEA MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE (#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF #4 AWG OR LARGER) 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM #8AWG WHEN INSULATED, #6AWG WHEN EXPOSED TO DAMAGE. 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR) 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 4. UV RESISTANT CABLE TIES(NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A -B). 300.4 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE -2, AND SINGLE -CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC -ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC CONDUCTOR SIZE CALCULATIONS MICROINVERTER TO MAX. SHORT CIRCUIT CURRRENT (ISC) = 14.0 A AC JUNCTION BOX (1) MAX. CURRENT (ISC X1.25) = 17.5 A AC CONDUCTOR (TC -ER, COPPER (90°C)) = 12 AWG CONDUCTOR RATING = 30 A AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 28.8 > 17.5 JUNCTION BOX TO MAX. SHORT CIRCUIT CURRRENT (ISC) = 14.0 A AC JUNCTION BOX (2) MAX. CURRENT (ISC X1.25) = 17.5 A AC CONDUCTOR (UF -B, COPPER (60°C)) = 12 AWG CONDUCTOR RATING = 20 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 19.2 > 17.5 JUNCTION BOX TO MAX. SHORT CIRCUIT CURRRENT (ISC) = 14.0 A AC COMBINER BOX (3) MAX. CURRENT (ISC X1.25) = 17.5 A AC CONDUCTOR (UF -B, COPPER (60°C)) = 12 AWG CONDUCTOR RATING = 20 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 19.2 > 17.5 COMBINER BOX TO INVERTER RATED AMPS = 14.0 A AC MAIN PV OCPD (15) MAX. CURRENT (RATED AMPS X1.25) = 17.5 A AC CONDUCTOR (THWN-2, COPPER (75-C TERM.)) = 10 AWG CONDUCTOR RATING = 35 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 33.6 > 17.5 690.8] FOR MULTIPLE CONDUCTORS 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8" ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (13)(2)(a), NEC TABLE 310.15(13)(3)(a),& NEC 310.15(13)(3)(c)]. 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE -2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V 11. 4 -WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY EUTRAL- WHITE/GRAY * USE -2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE ** USE -2 IS AVAILABLE AS UV WHITE 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH NEC 230.6(4) AND SECURED NO GREATER THAN 6' APART PER NEC 330.30(8). BLUE RAi 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. sir rCERTIFIED� PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 City of \ - s: .0C O 70 Cu _O O U N i -a UCu C� � C:(a ti Cu 00 �> N 00 W N_ U) W U) 0 DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME ELEC. CALCS. PAGE NUMBER REVISION PV6 B ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION r DIRECT CURRENT PHOTOVOLTAIC, PCIVVER SOURCE VOLTAGEMAXIMUM i MAX CIRCUIT CURRENT AMPS 1 i � RATEDAG OUTPUT CURRENT A NOMINAL OPERATING AC VOLTAGE V zhWARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM z WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE .: •'WA R N I N G 4 THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. PHOTOVOLTAIC SYSTEM CONNECTED PV AC DISCONNECT LABEL 1 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B), NEC 705.22] LABEL 2 AT EACH DC DISCONNECTING MEANS, INCLUDING THE DC DISCONNECT AT THE INVERTER. [NEC 690.53, NEC 690.13(B)] LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABEL 4 IF INTERCONNECTING ON THE LOAD SIDE, INSTALL THIS LABEL ANYWHERE THAT IS POWERED BY BOTH THE UTILITY AND THE SOLAR PV SYSTEM: THE MAIN SERVICE PANEL AND SUB -PANELS. [NEC 705.12(B)(3)] LABEL 5 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(b)] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO 5MME MC SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THEARRAY rf , it Ir� TURN RAPID SHUTDOWN SWITCH TO THE'OFF POSITION TO SHUT DOWN CONDUCTORS , --- -- OUTSIDE THE ARRAY -- -- CONDUCTORS NIITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT RAPID SHUTDOWN TEST NOT REQUIRED LABEL 7 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 1OFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 8 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 9 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(B)] LABEL 11 SIGN LOCATED AT AC COMBINER BOX FOR ALL MICRO -INVERTER /AC MODULE INSTALLS (IF APPLICABLE). " & WARNING LABEL 15 PERMANENT DIRECTORY TO BE LOCATED AT PANEL MAIN SERVICE EQUIPMENT LOCATION IF ALL MAIN DISTRIBUTION UTIUTY13ISCONNECT(S) ELECTRICAL POWER SOURCE DISCONNECTING POWERTOTHIS BUILDING IS ALSOSUPPLIED MEANS SOLAR ARRAY RAPID SHUTDOWN FROM A ROOF MOUNTED SOLAR ARRAY WITH (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS A RAND SHUTDOWN DISCONNECTING MEANS SWITCH) ARE GROUPED AND IN LINE OF SITE OF GROUPED AND LABELED WITHIN LINE OF SITE MAIN SERVICE DISCONNECTING MEANS. AND 10 FT OF THIS LOCATION. [NEC 690.56(C) & NEC 705.10]. ®►WARNING POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MAIN DISTRIBUTION UTILITY DISCONNECT LOCATED ®WARNING POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAY. SOLAR ARRAY RAPID SHUTDOWN DISCONNECT IS LOCATED OUTSIDE NEXT TO UTILITY METER. LABEL 16 PERMANENT DIRECTORY TO BE LOCATED AT SOLAR ARRAY RAPID SHUTDOWN SWITCH DENOTING THE LOCATION OF THE SERVICE EQUIPMENT LOCATION IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10] LABEL 17 PERMANENT DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION OF THE PV RAPID SHUTDOWN SYSTEM DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10, NEC 690.56(C)(1)] LABEL 12 PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. LABEL 13 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY. LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] LABELING DIAGRAM FOR STRING INV. / DC OPTIMIZER INV.: LABELING DIAGRAM FOR MICRO INV.: PANEL EXISTING SUB PANEL (IF WHERE POINT OF SUBPANEL- 00 MAIN SERVICE PANEL O & O IF BREAKER USED INTERCONNECTION IS MADE) O (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS OR9 00 EXISTING SUB PANEL (IF WHERE POINT OF 15 OR 17 PV COMBINER SUBPANEL - LABEL 6 (ONLY IF 3 OR MORE SUPPLY SOURCES TO 12 INTERCONNECTION IS MADE) AC DISCONNECT (IF REQ. / INSTALLED) IF USED TO COMBINE AC JUNCTION BOX PV OUTPUT CIRCUITS OR AC COMBINER BOX A BUSBAR) 13 INTERCONNECTION INTERCONNECTION INTEGRATED SIGN LOCATED AT LOAD CENTER IF IT CONTAINS 3 OR MORE POWER SOURCES.° ° O O O O O [NEC 705.12(13)(2)(3)(C)]° O& O ° ° IF BREAKER USED 13 10 O O 15 OR 01 O&O4 16 6 O OR PLACARD fn 0LU G O(U Z O IF BREAKER USE � 11 W U) (ONLY IF PV 1` 00 CV CU C 0 0 LABEL 10 INTERCONNECTION SIGN LOCATED AT RAPID SHUT DOWN COS SISTS OF LOAD DISCONNECT SWITCH [NEC 690.56(C)(3)]. DE BREAKER) LABEL 12 PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. LABEL 13 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY. LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] LABELING DIAGRAM FOR STRING INV. / DC OPTIMIZER INV.: MAIN SERVICE PANEL EXISTING SUB PANEL (IF WHERE POINT OF SUBPANEL- 00 12 O & O IF BREAKER USED INTERCONNECTION IS MADE) O (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS OR9 O&O O O O 15 OR 17 IF BREAKER USED 16 13 O4 O OR PLACARD 5 O O (ONLY IF PV (ONLY IF PV On O INTERCONNECTION INTERCONNECTION INTEGRATED CONSISTS OF LOAJ CONSISTS OF LOAD SIDE BREAKER) SIDE BREAKER) PV COMBINER INVERTER (S) SUBPANEL- AC DISCONNECT IF USED TO COMBINE (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS O O O 16 13 O4 O AC Z pl O On O DC DISCONNECT INTEGRATED JUNCTION BOX OR COMBINER BOX O *ELECTRICAL DIAGRAMS SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. FCERTIFIED] PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 X DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME LABELS PAGE NUMBER REVISION PV8 I B 0 O 00 00 O (U O o N ?j fn 0LU G O(U Z U (U >` cn W U) O CU 1` 00 CV CU C 0 0 DRAWING BY DIN ENGINEERING DATE May 14, 2020 PROJECT NUMBER 71843692 SHEET NAME LABELS PAGE NUMBER REVISION PV8 I B Data Sheet Enphase Microinwerters Region: AMERICAS Enphase IQ'7 and IQ 7+ Microinverters ED -1-1 1 ea m rn ore abo ut Enphase offerings, visit enphase,c orn The high-powered smart grid -ready Enphase IQ y Micro' and Enphase IQ }+ Micro~ d ramatica I�y simpl ify the in sta I latio n process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ hal icroi everters i rlteg rate with the En pha se IQ Envoy'", En p ha se I Q Battery', and the E nph ase Enlighten' monitoring and analysis software. IQ Series M icro i nve iters extend the reliability ,la ndard s set forth by p revious generation s a nd u ndergo over a mil I ion ho u rs of power -on test in g, enabling Enphase to provide an industry-leading 4y. a rra my of u p to 2 5 yea rs- Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling guiFt-in rapid shutdown compliant. (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60 -dell and 72-c-41* modules • More than a million hogs of tetating • Class II double insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements. Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741 -SA) * The IQ 7+ MI= rs required to suppart 72 -cell modules . E1PHAE, Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings' 235 W - 350 W + 235 W - 440 W + Module compatibility 60 -cell PV modules only 60 -cell and 72 -cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V - 37 V 27V -45V Operating range 16V -48V 16V -60V Min/Max start voltage 22 V / 48 V 22V/60V Max DC short circuit current (module Isc) 15 A 15A Overvoltage class DC port II II DC port backfeed current 0 A Ambient temperature range 0 A PV array configuration 1 x 1 ungrounded array, -No additional DC side protection required; Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA - PV2 to UTX: order ECA -S20 -S25 295 VA Maximum continuous output power 240 VA 1.08 kg (2.38 lbs) 290 VA Nominal (L -L) voltage/range2 240V/ 208V/ 240V/ 208V/ 211-264 V 183-229 V 211-26 4 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L -L) branch circuit3 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Yes PD3 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor Ambient temperature range -40°C to +65°C Relative humidity range 4% to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q -DCC -5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Both options require installation of an Enphase IQ Envoy. Adaptors for modules with MC4 or UTX connectors: The AC and DC connectors have been evaluated and approved by UL for use as the load -break - PV2 to MC4: order ECA -S20 -S22 disconnect required by NEC 690. - PV2 to UTX: order ECA -S20 -S25 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Pollution degree Enclosure Environmental category / UV exposure rating Yes PD3 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741 -SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES -0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at haps://enphase.com/en-uslsuppori/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements odeefine the number of microinverIers per branch in your area. To learn more about Enphase offerings, visit enphase.com v E N P H AS► EP © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 '11�10 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. FCERTIFIED I PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NSS UMBBER I REVISION 0 Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) The Enphase IQ Combiner 3T" with Enphase IQ EnvoyT" consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2 -pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular I • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring UL LISTED To learn more about Enphase offerings, visit enphase.com Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2 -pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year warranty • UL listed v ENPHASE. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X -IQ -AMI -240-3 IQ Combiner 3 with Enphase IQ Envoy" printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect" CELLMODEM-03 (4G / 12 -year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G / 5 -year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE -M / 5 -year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring* CT CT -200 -SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5%). Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK IOA-2-240 Circuit breaker, 2 pole, 1OA, Eaton BR210 BRK 15A-2-240 Circuit breaker, 2 pole, 15A, Eaton BR215 BRK 20A -2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PGB) for Combiner 3 Nor - BLUE RAVEN a. 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. ELECTRICAL SPECIFICATIONS r CERTIFIED duty Rating Continuous System voltage 120/240 VAC, 60 Hz PV INSTALLATION Eaton BR series busbar rating 125 A PROFESSIONAL Max. continuous current rating (output to grid) 65A Scott Gurney # PV -011719-015866 Max. fuse/circuit rating (output) 90A CONTRACTOR: Branch circuits (solar and/or storage) Up to four 2 -pole Eaton BR series Distributed Generation (DG) breakers only (not included) OPS BS RS RS FIELD LD Max. continuous current rating (input from PV) 64A 00 Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 lbs) Ambient temperature range -40° C to +46° C (400 to 115° F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated W i-Fi 802.11 b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE -M) (not included) COMPLIANCE Compliance, Combiner UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003'` " Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1��p * Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. 4M E N P H AS E. 2018-09-13 `0 SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 Residential Module MULTI-BUSBAR120 HALF -CELL BOB MODULE 1Z0 -Cell MONOCRYSTALLINE MODULE 310-335W POWER OUTPUT RANGE 19.7% MAXIMUM EFFICIENCY O^j+5W POSITIVE POWER TOLERANCE Founded in 1997, Trina Solar is the world's leading total solution provider for solar energy. With local presence around the globe, Trina Solar is able to provide exceptional service to each customer in each market and deliver our innovative, reliable products with the backing of Trina as a strong, bankable brand. Trina Solar now distributes its PV products to over 100 countries all over the world. We are committed to building strategic, mutually beneycial collaborations with installers, developers, distributors and other partners in driving smart energytogether. Comprehensive Products and System Certificates IEC61215/IEC61730/IEC61701/IEC62716 ISO 9001: Quality Management System ISO 14001: Environmental Management System IS014064: Greenhouse Gases Emissions Veriycation OHSAS 18001: Occupation Health and Safety Management System 11STED C E �A�� Tmasolar FRAME COLOR: Black High power output • Reduce BOS cost with high power bin and module efficiency e New cell string layout and split] -box location reduces the energy loss caused by inter -row shading • Lower resistance of half -cut cells and increased MBB (Multi Busbar) reflectance ensure higher power High energy generation, low LCOE • Excellent 3rd party validated IAM and low light performance with cell process and module material optimization • Low Pmax temp coefficient (-0.36%) increases energy production • Better anti -shading performance and lower operating temperature Outstanding visual appearance, easy to install • Designed for superior rooftop aesthetics • Thinner wires give a eye cacthing all black look • Safe and easy to transport, handle, and install Certified to perform in highly challenging environment • High PID resistance through cell process and module material control • Resistant to salt, acid, sand, and ammonia • Over 30 in-house tests (UV, TC, HF etc) • Certified to 5400 Pa positive load and 2400 Pa negative load PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Power Warranty 100% 97.570 ■ Trina Standard a 3 90% v m C ° 83.1% �o u Amon Years 5 10 15 20 25 From the 2nd yearto the 25th year, the average annual power decline will be no morethan 0.6%. Residential Module DIMENSIONS OF PV MODULE(mm) NamePla�e 4-09x14 Installing Hole AL JA �una� �oz 604.3 Grounding Hole 12 -Drain Hole m loon String Inverter Configuration 959 NamePla�e 4-09x14 Installing Hole AL jA funRion Boz LDrain Microinverter or Optimizer Configuration 11.5 Silicon Sealant 8 Silicon Sealant LaminaterFrame Frame 35 24.5 A -A B -B I-V CURVES OF PV MODULE (335W) 11.0 10.0 1000 e.0 11.0 800W/ 2 7.0 6.0 600W/m v 5.0 4.0 400 m 3.0 2.0 200W/m 1.0 0 10 20 30 40 50 Voltage(V) P -V CURVES OF PV MODULE (335W) 350 1 W/m' 300 m 250 600W/m2 200 v 3o150 400.. 100 200W/m2 so 11 0 10 20 30 40 50 Voltage(V) MULTI-BUSBAR 120 HALF -CELL BOB MODULE ELECTRICAL DATA (STC) 320 Peak Power Watts-PMAx (Wp)* 310 Power Output Tolerance-PMAx (W) 238 Maximum Power Voltage-VMPP (V) 33.0 Maximum Power Current-IMPP (A) 9.40 Open Circuit Voltage-Voc (V) 39.9 Short Circuit Current-Isc (A) 10.03 Module Efficiency TI m(%) 18.2 STC Irradiance 1000W/m2, Cell Temperature 25oC, Air Mass AM 1.5. Measuring tolerance: ±3%. 9.85 315 320 325 330 335 238 05 31.0 31.2 Maximum Power Current-IMPP (A) 33.2 33.4 33.6 33.8 34.0 9.49 9.58 1 9.67 9.76 9.85 40.1 40.3 40.4 40.6 40.7 10.12 10.20 10.30 10.40 10.50 18.5 18.8 19.1 19.4 19.7 ELECTRICAL DATA (NMOT) 250 254 Maximum Power- PMAx(Wp) 235 238 Maximum Power Voltage-VMPP (V) 31.0 31.2 Maximum Power Current-IMPP (A) 7.57 7.64 Open Circuit Voltage-Voc(V) 37.6 37.8 Short Circuit Current-Isc (A) 8.08 8.15 NMOT: Irradiance at 800W/m2, Ambient Temperature 20oC, Wind Speed 1m/s. MECHANICAL DATA 242 246 250 254 31.4 31.6 31.7 31.9 7.71 7.79 7.86 7.94 38.0 38.1 38.3 38.4 8.22 8.30 8.38 8.46 Solar Cells Monocrystalline Cell Orientation 120 cells (6x 20) Module Dimensions 1698 x 1004 x 35 mm (66.85x 39.53 x 1.38 inches) Weight 18.7kg (41.21b) Glass 3.2mm (0.13 inches), High Transmission, AR Coated Tempered Glass Encapsulant Material EVA Backsheet Black Frame 35 mm (1.38 inches) Anodized Aluminium Alloy ]-Box IP 68 rated Cables Photovoltaic Technology Cable 4.Omm2 (0.006 inchesz) (Do not connect Fuse in Combiner Box with two Portrait: N 140mm/P 285mm (5.51/11.22 inches) connection) Landscape: N 1200 mm /P 1200 mm (47.24/47.24 inches) Connector MC4 TEMPERATURE RATINGS MAXIMUM RATINGS NMOT(Nomina l Module OperatingTemperature) 41°C(±3°C) Operational Temperature -40-85°C Temperature Coefficient of PMAx 0.36%/°C Maximum System Voltage 1000V DC (IEC) Temperature Coefficient of Voc 0.26%/°C 1000V DC (UL) Temperature Coefficient of Isc 0.04%/°C Max Series Fuse Rating 20A (Do not connect Fuse in Combiner Box with two or more strings in parallel connection) WARRANTY PACKAGING CONFIGURATION 10 year Product Workmanship Warranty Modules per box: 30 pieces 25 year Power Warranty Modules per 40'container: 780 pieces (Please referto product warrantyfordetails) 111�6 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. zi NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 .rom�Ncity C* � 1. f, 0 s-�.ZaZa CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Tir*inasoiar Version number: TSMSHEET NAME © 2019 Trina Solar Limited. All rights reserved. Speciycations included in this datasheet are subject to change without notice. SPEC SHEET _DD06M.05(II)_EN_2019_B www.trinasolar.com PAGE NSS UMBER I REVISION 0 am 04 11� 0 0 3 3 [77.09mm] 3.04in 0 ITEM NO. PART NUMBER DESCRIPTION QTY. JB -1 Body w/ E -Z LOK POLYCARBONATE WITH UV 1 TECHNOLOGY INHIBITORS 1 2 JB -1 Lid w/ Gasket POLYCARBONATE WITH UV 1 INHIBITORS 3 10-32 x 1 " Phillips pan head bolt 4 #8 x 1-1 /4" Phillips 4 pan head screw iue Specification: tifications: ght (LBS): 15-20 lbs -in UL Standard 1741, NEMA3R 1.3 lbs DATE EZ Solar SLC, UT USA Phone (385) 202-4150 www.ersolarproducts.com TITLE: EZ SOLAR SIZE G. NO. REV 6 JB -1 SCALE: 1:2 WEIGHT: SHEET 1 OF 3 1 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE B WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. zi NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 0 CRY of �Azozo SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 [304. � 12. 0 4 3 2 F17n 7gmml [57.94mm] 2.28in [9.53mm] 0.38i n [5.55mm] 0.22i n SECTION A -A SCALE 1 : 1 Fr, r, RQ m ml [57.94mm] 2.28in 10.50i n UNLESS OTHERWISE SPECIFIED: NAME DATE DIMENSIONS ARE IN INCHES DRAWN TOLERANCES: FRACTIONAL± TITLE: CHECKED ENG APPR. ANGULAR: MACH 2: BEND ± TWO PLACE DECIMAL ± C EZ SOLAR MFG APPR. THREE PLACE DECIMAL ± INTERPRET GEOMETRIC Q.A. PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: COMMENTS: MATERIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SIZE DWG. NO. REV EZ SOLAR. I D NEXT ASSY USED ON FINISH ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN J D PERMISSION OF EZ SOLAR IS PROHIBITED. APPLICATION DO NOT SCALE DRAWING SCALE: 1.2 WEIGHT: SHEET 2 OF 3 4 3 2 1 0 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. zi NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 city Of .S.Z02-0,il SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 0 rd SECTION A -A SCALE 1 :2 I 4 w [3.18mm] .13in LID OVERHANG 3 OUTSIDE A f I � 2 -nm] In [22.23m m] .88in INSIDE BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE B WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. zi NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 0 SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 UNLESS OTHERWISE SPEC IFI ED: NAME DATE DIMENSIONS ARE IN INCHES DRAWN TOLERANCES: FRACTIONAL± TITLE: CHECKED ENG APPR. ANGULAR: MACH± BEND t TWO PLACE DECIMAL ± C EZ SOLAR MFG APPR. THREE PLACE DECIMAL ± INTERPRET GEOMETRIC Q.A. PROPRIETARY AND CONFIDENTIAL TOLERANCINGPER: COMMENTS: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MATERIAL SIZE DWG. NO. REV ANY NEXT ASSY USED ON FINISH REPRODUCTION IN PART OR AS A WHOLE REPRODUEZ CTION WITHOUT THE WRITTEN PERMISSION OF 6 J13-1 <INSERT COMPANY NAME HERE> IS PROHIBITED. SCALE: 1:2 WEIGHT: SHEET 3 OF 3 1 APPLICATION 2 DO NOT SCALE DRAWING 3 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE B WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. zi NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 0 SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 111�6 ;SFS°"SYSTEM BONDING & GROUNDING E BLUE RAVEN is OEM ; M FRAME IINSTALLATION GUIDE 'I PA6E q N RESEARCH °800-377-4480 "'"°'°� BUILDING Ste r Washer is Single Use Only TERMINALTORQUE, Install Conductor and torque to the foLLowir 4.6 AWG: 35in-lbs 8 AWG: 25 in -Lbs 10-14 AWG: 20 in -Lbs TERMIINALTORQU9, Install Conductor and torque to the following: 4.14 AWG: 3 Sin -Lbs WEEBLUG Single Use Only TERMfINALTORQUE, InstaLL Conductor and torque to the following: 6-14 AWG: 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Rsco Lay -In Lug (GBL4DBT) Rsco Flange Lug(SGB-4) WiLey WEEBLug {6.7} • 10-32 mounting hardware 0 1/4" mounting hardware 0 1/4" mounting hardware * Torque = 5 ft -lb • Torque= 75 in -lb • Torque = 10 ft -Lb • AWG 4 -14 -Solid or Stranded AWG 4-14 -Solid or Stranded • AWG 6 -14 -Solid orStranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module at a location on the module specified by the module manufacturer. E -W BONDING PATH: E -W module to module bonding is accomplished with 2 pre-instaLLed bonding pins which engage on the secure side of the MicroraiLTM and splice. 00 nf' N -S BONDING PATH: N -S module to module bonding is accomplished with bonding cLampwith 2 integral bonding pins. (refer also to alternate method ) J - Attemate method TRIMRAIL BONDING PATH: Trimrail to module banding is accomplished with bonding clamp with integral banding pin and banding T -bolt. {refer also to alternate method ) CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. w I n r►r+r11 FCERTIFIEDD PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 "I' C" or 5 - SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 Intertek Total Quality. Assured. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. I This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Cixi Emeka Aluminum Co. Ltd Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev Product: No. 688 ChaoSheng Road Address: 1411 Broadway Blvd NE Address: Cixi City Albuquerque, NM 87102 Zhejiang Province 315311 Country: USA Country: China Klaus Nicolaedis Jia Liu Contact: Tom Young Contact: Robin Luo 505-462-2190 +86-15267030962 Phone: 505-843-1418 Phone: +86-13621785753 FAX: NA FAX: NA klaus.nicolaedis@unirac.com jia.liuCa cxymj.com Email: toddg@unirac.com Email: buwan.luo agcxymj.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA U.S.A. Control Number: 5003705 Authorized by: I WAY-kj- _Le�2� Z for Dean Davidson, Certificati 010Manager W )U; (Qs-mv Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Fallow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 ATM for Report 102393982LAX-002 Page 1 of 1 ATM Issued: 9 -Apr -2019 ED 16.3.15 (20 -Apr -17) Mandatory 111�6 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. zi NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 "„y ' % i (/V ��aza SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 Mounting Systems, Mounting Devices, Clam ping,1Retention Devices, and Ground Lugs for Use with Flat - Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev Product: PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 1 ATM Issued: 9 -Apr -2019 ED 16.3.15 (20 -Apr -17) Mandatory 111�6 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. zi NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 "„y ' % i (/V ��aza SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 "'so, S FM FRAMICRORAILTMME FLASHING & SLIDERS G no � INSTALLATION GUIDE PAGE --------------------------------------------------------------------------------------------------------------------------------------------- PILOT HOLES: Drill pilot holes for lag screws or structural screws (as necessary) at marled attachement points FLASHINGS: Place flashings INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: • 1 nsert flashi ngs per man ufactu rer instructions NOTE; Use Lag screw or structural fastener with a maximum diameter of 5/16" • Attach sliders to rafters • Verify proper row to row spacing for module size (Mod NS + 1") • Ensure that Tri mraiLTM roof attachments in each row have sufficient engagement with slider dovetails for proper attachment. - INSTALL SLIDERS AND ROOF ATTACHMENTS: FoLLow manufacturer instructions forflashing installation procedures _NOTE: if N -S module edge is within 1" of the shingle course above, you have the option to pivot / rotate slider at the attachment point to span the next course and cut shingles as required. Cut Shingles as Required I Rotate Slider •--— —+--—�i--1---_-.iii s�-- ---- N/S MODULE EDGE ! II -- -Less Than 1"1= it 11 11 11 Ii • Mod NS + 1" Mod NS + 1" 111�6 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. rCERTIFIED I PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: ADDRESS:` ` ti ; JOB CODE: Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground C Uu i'mut Gover unaergrouna or Beiow i in -Slab work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof C 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMADDRESS:'"%Cr- JOB CODE:' Rough Inspection (continued) Date Inspector CommentsInitials 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector CommentsInitials 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** Inspection* BuildinZoninggFinal F418Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. A i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 49 Job Address: "J ' L ,meq I F. Permit Number:�-- ❑ No one available for inspection: Time �m ` AM/P, M Re -Inspection required: Yes /No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: /' 6 I DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: do� Job Address: ` Permit Number: 20 1%0q % U4— � �2 Irk LL f k t -50F /1- ❑ No one available for inspectio : ! } e Re -Inspection required: Yes NN when corrections have been made, call for re-inspe on at 303-234-5933 r Date: Inspector: J DO NOT REMOVE THIS NOTICE I t (*) City of Wheat Ridge Residential Roofing PERMIT - 201709204 PERMIT NO: 201709204 ISSUED: 11/21/2017 JOB ADDRESS: 2876 Gray ST EXPIRES: 11/21/2018 JOB DESCRIPTION: Tear down to deck and install ice and water with new drip and rake edge metal; install 30# felt w/Heritage 30 yr dimensional. Pitch is 5/12 and total number of squares is 23. *** CONTACTS *** OWNER (303)233-4157 CREEL CLIFFORD R SUB (303)443-5843 Rami Zarifa 018891 B & M Roofing of Colorado *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,343.00 FEES Total Valuation 0.00 Use Tax 49.20 Permit Fee 93.35 ** TOTAL ** 142.55 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge '4 Residential Roofing PERMIT - 201709204 PERMIT NO: 201709204 ISSUED: 11/21/2017 JOB ADDRESS: 2876 Gray ST EXPIRES: 11/21/2018 JOB DESCRIPTION: Tear down to deck and install ice and water with new drip and rake edge metal; install 30# felt w/Heritage 30 yr dimensional. Pitch is 5/12 and total number of squares is 23. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. l further attest that I am legally authorized to include all entities named within this document as partes to the work to be performed and that►all wdrk to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. r Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3 If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off-cial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 5. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature ofVhi, dittg,OfB'bi( ry Date REQUESTS MUST BE MADE BY 11: MI ANY INESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 67b1�C� l Kimberly Cook From: no-reply@ci.wheatridge.co.us Sent: Tuesday, November 21, 2017 2:04 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address 2876 Gray Street Cliff Creel 303-670-0253 Field not completed. Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Binder1.pdf Contract CONTRACTOR INFORMATION Contractor Business B&M Roofing Inc. Name Contractor's License 018891 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-443-5843 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 3768 Eureka Way (Primary address of your business) Contractor Email Address btaylor@bmroofing.com Retype Contractor Email btaylor@bmroofing.com Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or both? (check all that apply) 23 2343 No Pitched roof (2:12 pitch or greater) i and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Linda Garcia Email not displaying correctly? View it in your browser. What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 5/12 23 Heritage 30 Year Dimensional Asphalt House -tear down to deck, Install Ice & Water w/new drip & rake edge metal, Install 30# Felt w/ Heritage 30 yr dimensional SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application Yes Yes Yes Yes 9 10/25/2017 210:31 3036793172 B&A-1 Roofing of Colorado Inc. "Quality His No `substitute, Aeoend on Us" y' 3768 .Eureka Way, .Rrederiie[4 CO 805145 H&M ,R00FIN rLune: (303) 443-5343 Fax: (303,)938-9642 T3.� flp )tQCIT71A1G SI'S TEA1 PI? OP0SA.L & AGREE[51ElVT Prop080Submitted to: Country craftsman 29506 Bronco Road Date, August 24, 2017 Plione: 303-670-0253 Erttail/Fax. 303-679=3172 Evergreen, CO 80439 Job: Creel Property (R.esidmec) Mr. Cliff Creel Location: 2876 Grey Street Wheatridge, CO 80241 ROOFING SYSTEM DESCRIPTION R. PROPOSAL _� l 453 & M Roofing proposes to do the foll0.ving work`at'thc above referenced property. SURF,\\ F PREPARATION • Remove and dispose of one layers of existing composition rooting material. • Inspect plywood roof creek and rc-sccure any loose sheets. 1 • llCplilGC rUttCnlWFjtGr dtttnaged plyw{)i)d i1,t1.CZ' cpprVYal by (71N[I4T- If this wvik is rCritttreJ, it brpvxtite time and material price of $60.00 per sheet will be added. UNDERLAYMENT • rns#ill ic£ said wat£rshi£ld 24" inside wall at bower eave edge of roof, per code. « instal.( one layer of 30 -pound ASTM 4869 felt underlayment over entire roof surface_ « Install Tarco valley liner in valley areas, closed style. FLASHINGS • lnstall new 2" x 4" prefinished white drip edge flashing at lower eave edge, atad rake edges of roof, • Install and paint new vent ffashhigs on pipe penetrations. + lastall and paint new attic vents to facilitate proper attic/roof ventilation. • All flashings to be 26 gauge prefinished, unless otherwise noted. ROOFING SYSTEM PAGE 02/02 « bstabl new HE, RIT.A.GE 30 YEAR wMENS.ION.L ROOD NG SYSTIEM, DUD as manufactured by TAMKO, over underlaymeut, including all starter, bip and'ridge. • Color said mar'ufacturer will be chosen by Owner, prior to matcrial order by B&M. Roofuig. TAXES AND MISCELLANEOUS P d • Dobrls Caused by thg; rooting oprratlon will be properly disposed of by Ii&M Roofing. « Liability and worknieres compensation insurance is carried by our firm for your protection- + Applicable sales tax on tnaterials included in our System Price on this project. + The applicable city building permit foo is included in outr System l'rloe. • We will complete the roofing work utilizing the driveway to access the property. ,{ . roll -off garbage conisiner, or trailer will be located in the driveway during the re-rooflng project. • We will provide a 5-yntir l3&M Roofing of Colorado, rnc.'s roofing guarantee on labor upon completion of the work and receipt of final paymetit. + .rA standard 30- manufacturer's warranty covering material will be provided upon completion of the work and receipt of payment. + Gutters, siding, carpentry, and soffit venting are excluded from System Price on this project ..710W .laPURI AGE 30 YEAR DIA EN,SIOXA E R()O.r'.LNG-87ST',�ff.i°RrCE. $6,39$.00. OFTIN Ill: To Inistall new 3" Seamless gutter, and 2" x 3" co ru ter! dawuspout. ADD TO SYSTEM PRICE: $1,042.00 Ial to accent) OPTION #2: To instal) Ii4" den � all I i7EPDM rubber over patio roof, flash around curb. ADD TO SYST bQQ.QQ _.. __(Witial to accept) Thank you for the opportunity to submit this proposa). Plcasc contact us with any questions yoti rosy have. Vde look forward to servicing your needs on this project. Accepted by: Date:_ t01 'Z 6 f / ' Proposal Good for thirty 69�days. kAuthod7cd Signature Brad. Taylor, Vice President • %accept, sign mid reuirn nae cgpy. . • (,.lweerrs�ilf prpuida cr:rtifictrfipn 8uaronfeer>tg fltllt funds hltv.: Itn..stE ,rel hS/Ylr:,jdYpr�merti, ifrequestec� • .PLtance c/aarges ofLS percent per tnondli (i84p A.P.R.) tvill be ad¢rd to any ur6p[itc6btrtotrr E; t Owne„r.yrraff be resportsible,for all ctcarges {inclrc(fng attnrxey's fees) related tV colledl(m tff otYs by eordraefUr • H,4I If RnolN.e .Smn,l ud f err?roil Qviefitions are attached and infide apart It etaof Ill a t � t i • t .: r „ Bldg Vatus"on "a • ar a r + City of Wheat Odge Residential Me hanic PERMIT - 060710 PERMIT NO: JOB ADDRESS: DESCRIPTION: 060710 2876 GRAY ST inst. 90,000 BTU Furnace ISSUED: 08/08/2006 EXPIRES: 02/08/2008 Coffman to do electrical *** CONTACTS *** 303/431-8914 303/420-1516 303/233-4157 J. Patrick Qui Ian 01-8464 B & F Heating & A/C 01-7875 Coffman Electric, Inc gc sub owner Allen Kirby ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: UA USE: BLOCK/LOT#: UA 0/ Permi t Fee Total Valuation ** TOTAL ** ESTIMATED PROJECT VALUATION: FEES 181.10 .00 181.10 6,085.00 ** FEE SUMMARY ** Comments: electrical must meet 2002 NEC subject to field inspection I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulatione of the City of Whea Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegat~ons made are accurat ; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility fo compliance with the Wheat Ridge Building Code (l.B.C) and all other applicable Wheat Ridge Ordinance'. for work under th s per~'~bject to field in'pection. Sign tu e of contractorwner date 1. This permit was issued in accordance with the pro isions set forth in your application and is subject to the laws of the State of Colorado and to thei zoning Regulations a d Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire if (A) the work authoriz d is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expires, a new permit may be acqui ed for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or i suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall ~e done that will cha 5. Contractor shall notify the Building Inspector tw written approval on inspection card before procee 6. The issuance of a permit or :the approval of drawi an app~~i~:~.. rovisions 0 All plan r s~t 1~~ field ins ctions. "~ .. signature of Chief Building Off~cal ge the natural flow of water causing a drainage problem. nty-four (24) hours in advance for all inspections and shall receive ing with successive phases of the job. gs and specifications shall not be construed to be a permit for, nor the building codes or any other ordinance, law, rule or regulation. date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSIN SS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ~itv of Wheat Rid PRESC PTIVE EN R ~ y~ BOILERS / FURN CES A MINIMUM OF 90'/' '.FUE GAS WATE.R HE.ATER A MINIMUM OF .60 ENER:. " FACTOR E~CTRIC WA'IER HEAT RS A IIAINIMUM OF .93 EI'/LRGY FACTOR SfTBACK THERMOSTA REQUIRED (EXCEPT HYDRONIC HEAT) R.21 WALLS . R-3 CEILINGS . R-19 CRAWLS PACES Rug 08 06 10:36a Patt:;l Schmidt 303-421-12S8 p.2 "~"""'./ !:c :f; o ~ "oLQR,.,ao COMMUNITY VELOPMENT DEPARTMENT BUILDING INSP CTION LINE - 303-2344933 CITY F WHEAT RIDGE 7500 ST 29TH AVENUE WHEAT RIDGE CO 80033 -(30~35-2S551 APPLICATION Building Permit Number: vh~ Dale: 1{(t3p Property Ov.ner: Property Address: Contractor License No.: Company: Phone: ?It:J,? 273' "lIS? Phone: OWNERICOHTRAClOR StGNAnJRE OF UNO RSTANDtNG Value:$ 6.ct'5<L Pennit Fee:$ /fJl ~ Plan Reyiew Fee:$ Use Tnx.$ TotaJ:$ /$ .f!2- ~ Use of Space (description): A? Description of work: 0' Sq. Ft. added LDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ONING COMMENTS: Approval: Zoning: BUilDING COMMENTS: Approval: PUBLIC \M:)RKS COMMENT$: _val: IRE DePARTMENT COMMENTS: Approval: Occu an Walls: Root. Stories: Residential Units: Electrical License No: /1fJ~ companyt~,a/7 Ot'c/r/C Expiration Date: A roval: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: A roval: Expiration Dale: A oval: (1) This permit was issued in accords vdlltle provisions set forth in your application and issubjec:tto the laws orlhe Slate of Colorado and to the Zoning Regulat cns and Building Codes of Wheat Ridge, Colonldo oranyotherapplleable ordinaneesof the City. (2) This permit shall expire If (A) the wo authorized Is not commenced wilhin sixty (90) days from issu& date or (B) 1he bulkling authorized Is suspended or abando ed for a period of 180 days. (3) If this permit expires. a new pennit y be acquired for a fee of on&>halfthe amount normaly requintd, provided no changes have been or will be made in the o' inalplllnsancl IPeclficatlons and any suspension or llbanclonmenthas not exeeeded one (1) year. If changes have been orif spensianor abandonment IXeoods ono (1) year, full '"sshaB be paktfora newpennit. (4) No wort< of any manner shall be do that will change the natural ftowofwater caU8ing a drainllg& probMm. (5) Contractor shaH notify the Bulklfng nspector twenty-four (24) hours in ad'Vance for all inspections and shallrecelv8 written approval on inspection card before roceeding with sUt:Ce$sive phon of the job. (S) The issuanoe of a permit or the ap val of drawings and speeifieations sh80 not be construed to be a permit for, nor In approval of, any violation of the visions of the building codes Of any other ordinanoe, hIw. N~ or regutation. All plan review is subject to field inspect ns.. Chief Building Officiai .v" .0:"'(;J,,.~:..' PLANNINGA DEVELOPMENT Building Permit Number: 4675 ECTI(>NDIVI ON . 236.2855 OF WHEAT I Date: 2/28/97 WEST 29TH A TRlDGE, CO I Pn)perty ProPertY Ad rBSS: 2876 GRA T CoOtractot Licen No.: 18958 ny: Edgewater Phone: ~33-4157 OWNER/CONTRActOR $1 Phone: 232 8650 ANDING AND AGREEMENT Construction Value': Pennit Fee ': Plan Review Fee!: Use Taxi: Total!: $500.00 $45.00 $0.00 $6.00 $51.00 !penn~ sl!Plication sre 8CC!lrste, s of \he City of Wheat RIdge or suremen18 shown, snd allegstlons II conditions printad on thIS 08 with the Wheal RIdge Building , for wOlt< under this penni!. . Description : DATE 2-2V-'17 VICE TO 150 AMPS BUlL NG DEPARTMENT USE ONLY SIC: SIil.Ft.: Approval: Occupancy : Walls: Roof: Stories: Residential uriits : l~l (6) LicBnse No : Mechanical Licen$e No : Company : Electrical License No : Company : Expiration Date : Approval: . Expi . n Date: Appro . Expiration Date : Approval: . (1) (2) (3) forth Inyoput IpIliIcs1lonsnd Is _ tolhe I8w8 01 the SI8t8 01 CoIor8lfo snd to1l1e ZOnIng sny otI18t s_bIe onIInsnces 01 the City. , wlthm alx1y (60) dsya from I88ue d.... or (8) 1I1e building _Is auspended or of one-h8lllhe 8lTlOunt normslly rsqulnld. _ no chsngeo _ be<!n 01' wlIl.be mode In tI18 ndonment hs8 not exceeded one (1) yssr. )f ch8I1gs8 sre mOdo 01' it........... 01'_ lunlI_ 01_ cauolna s dra'- poobIem. , ) ttounIln 8dv8noo lor 811 rnopocllona snd ahall racoIwl wrltIon spplOv8I 0Ij ~ canlbelora sh8l1 not be construed to be a permit for. nor on spplOv8I of. ~ vIoI8Ilon 0I1I1e pmvIsIon8 ief Bundi~g Ins THIS PERMIT V. LID ONLY WHEN . CALL: 2 GNED BY THE CHIEF BUILDING INSPECTOR AJljD MAYOR 324 HOURS PRIOR TO INSPECTION ' I I DEPARTMENT OF PLANNING A~D DEVELOPMENT Building Permit Number: , BUILDING INSPECTION DIVI$ION - 235-2855 CITY OF WHEAT RIDGE Date: 2 -26' -'17 7500 WEST 29TH AVENUE WHEAT RIDGE, CO i 80215 Property Owner: Property Address: Contractor License No. : Company: A 1/(""1-\ k irby 2. 'F:7" GJ"'Y ~ Use(S-g jJ'j': .,/, ,-f~ .l- E ) "<<-t I I <... Phone: ? S 3 - '-I Ff'? Phone: 2':> L- ;:"65.- C' OWNER/CONTRACTOR SIGNATURE OF UNDER~TANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: S~6 c~ I hereby certify that the setback distances proposed by th~' permit application are accurate, and do not violate applicable ordinances, rules or regulati ns of the City of Wheat Ridge or covenants, easements or restrictions of record; that all m asurements shown, and allegations made are accurate; that I have read and agree to abide b all conditions printed on this application, and that I assume full responsibility for complif1nce with the Wheat Ridge Building Code (U.B.C.) and all other applicable Whea.~ Rid:e ordin:,~c;r' f~r work under this permit. (OWNER)(CONTRACTOR) SIGNED _' ;::........,.: /"<::l-<.--V\ DATE 2 -23",,1 Description: C /-.I"'lrlje ,EI)"'CJ./1L Se'v,<ce +-0 /.)-0 /4.""P Total: ; BUILDING DEPARTMENT USE ONLY Z(~lf1Jfmc~QJ"m_nJ!Cl Approval: Zoning: B!!!.l!!lJm~I!mmEln.~ Approval: RDbl~Kn.l#pmmElJ:l~ Approval: SIC: Sq. Ft.: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbi~g License No : Company: Mechanical License No : Company: Expiration Date: Approval: . lmlam~.mI_ Expiratlon Date: Approval: . ~lilW!i9.!1!llY'~ Expiration Date: Approval: . e.OOIlIlR!m!ImI (1) (2) (3) This permit was issued in accordance with the provisions et forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Buildin~ Code of Wheat Ridj;le, Colorado lor any other applicable ordinances of the City. This permit shall expire If (A) the work authonzed is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 day's. If this permit expires, a new permIt may be acquired for a~e of one-half the amount normally required. provided no changes have been or will be made in the original plans and specifications and any suspension or a andonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new pe it. No work of any manner shall be done that will change the ratural now of water causing a drainage problem. Contractor shall notify the Building Insfector twenty.four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases 0 the/"Ob. : The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or r~gulation. (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION