Loading...
HomeMy WebLinkAbout2885 Gray StreetCITY OFWH AT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office * (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: /00 If Job Address: 3 Permit -Number: 3 J No one available for inspection: Time AM/PM Re -inspection required:( Yes--` No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE PERMIT: grO009903 ADDRESS:O\(JU 6yq JOB CODE. Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 7° 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 7° 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 'For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection' 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspectJion the following busine r -} - PERMIT: p ADDRESS:601AAJOB QDE: V ill, Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground I Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential F314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT NIP ADDRESS: JOB CODE: WF 1, �, ) -, INSPECTION REC D Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential ough Plumbing Commercial E35 hower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading ,. 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial ,. 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. a i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE I&lo3 Inspection Type:%�l%`� Job Address: 04),q� Permit Number: 201 �00010 31 ❑ No one available for inspection: Time t O AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: r Inspector: PnT y DO NOT REMOVE THIS NOTICE City of Wheat Ridge .� Residential Solar PERMIT - 201708903 PERMIT NO: 201708903 ISSUED: 11/13/2017 JOB ADDRESS: 2885 Gray ST EXPIRES: 11/13/2018 JOB DESCRIPTION: Permit to install a 3.9KW roof mounted Grid tied solar system. *** CONTACTS *** OWNER (303)842-9487 BARRETT BRETT ANDREW SUB (888)765-2489 Jared A Miller 110035 SolarCity Corporation *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,304.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have beela uthorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisppermit. I further attest that I am leg�ally authorized to include all entities named within this document as parties to the work to be perfiormed and that -all work to be pet, rmed is disclosed in this document and/or its' accompanying approved plans and specifications. t `fit 7 Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of ail required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official V Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of OMWheat Pidge MMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: j i TT TI--, Plan/Permit # Plan Review Fee: Building Permit Application P(� a�sEc *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 2885 Gray St, Wheat Ridge, CO 80214 Property Owner (please print): Alison Brody Phone: (610) 348-0904 Property Owner Email: mrbrettbarrett@gmail.com Mailing Address: (if different than property address) Address: Same as above City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor: Solar City Contractors City License #: 110035 Contractor E-mail Address: tward@solarcity.com Sub Contractors: --- Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: 253-720-4461 Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT BELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT x OTHER (Describe) Solar PV (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Install a 3.9 kW roof -mounted grid -tied solar PV system Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) _5304 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)�/ Chris Luther J ••• PRINT NAME: SIGNATURE: � �/^ , J-,_ DATE: 11/7/2017 ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: P. S (�() A ftovQ> I 0 i+ r) PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ September 26, 2017 RE: CERTIFICATION LETTER Project/Job # 8029174 Project Address: "Ali" Residence 2885 Gray St Wheat Ridge, CO 80214 AHJ Wheat Ridge SC Office Parker Design Criteria: - Applicable Codes = IRC 2012 / IBC 2012, ASCE 7-10, and 2012 NDS - Risk Category = II - Wind Speed = 135 mph, Exposure Category C, Partially/Fully Enclosed Method - Ground/Roof Snow Load = 30 psf (Unreduced) - MP2A: 2x6 @ 24" OC, Roof DL = 10 psf, Roof LL/SL = 30 psf - MP2B&3: 3x6 @ 24" OC, Roof DL = 11.5 psf, Roof LL/SL = 30 psf - MP4: 3x6 @ 24" OC, Roof DL = 11.5 psf, Roof LL/SL = 30 psf Version #17.8 - TBD RU O• •O • 49755 z 09/26/2017• �FSS��NAL EN�\� Table of Contents 1 Certification Letter 2 Hardware Design & Structural Analysis Summary 3 Loading Summary, Member Design Check, and ZEP's Uplift Calculations per Mounting Plane 4 Additional Sketches (If Applicable) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22567 < 0.4g and Seismic Design Category (SDC) = B < D To Whom It May Concern, Ajobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure, with upgrades specified in the attached sketch(es), directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it according to the schedule in this calculations package have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Digitally signed by Jason Toman Date: 2017.09.26 09:29:30 -07'00' T = 5 L n 41be 0161 01 atR; oan �9� 90;x. C- r- kt h111 Tesla, Inc. D Version #17.8 - TBD RU X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR 72" 7M7P2B13 24" 39" NA Staggered 57.0% 72" 24" 39" NA Sta ered 57.0% 72" 24" 39" NA Staggered 57.0% 64" NA Staggered 62.3% X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Confi uration Uplift DCR MP2A 48" 19" 64" NA Staggered 62.3% MP2B&3 48" 19" 64" NA Staggered 62.3% MP4 48" 19" 64" NA Staggered 62.3% Type Spacing Pitch Member Evaluation Results MP2A Stick Frame 24" OC 21 degrees Member Analysis OK MP2B&3 Stick Frame 24" OC 21 degrees Member Analysis OK w/ Upgrades as Specified in Attached Sketch(es) MR Stick Frame 24" OC 21 degrees Member Analysis OK w/ Upgrades as Specified in Attached Sketch(es) 10'0"1 8'0" All member analysis and/or evaluation is based on framing information gathered on site. The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. Tesla, Inc. T E 5 L n MP Name MP2A MP2B&3 MP4 SU Sheet NA SK1.2 SK1.2 Type NA 2x6 Parital Sister 2x6 Parital Sister X 1'4" 2'0" L 10'0"1 8'0" All member analysis and/or evaluation is based on framing information gathered on site. The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. Tesla, Inc. T E 5 L n Structural Calculations Package MP2A v17.8 9/26/2017 9:24 Load Itemization Net PV System Load PV Module Weight 2.5 psf Net PV System Weight 3.0 psf Hardware Assembly Weight (psf) 0.5 psf Roof Dead Load Non-PV Areas Material PV Areas Original/Existing Roofing Material 5.0 psf Comp Roof ( 2 Layers) 5.0 psf Re-Roof (Under PV Assembly) No 0.0 psf Underlayment 0.5 psf Roofing Paper 0.5 psf Plywood Sheathing 0.0 psf No 0.0 psf Board Sheathing 2.3 psf Solid-Sheathing 2.3 psf Rafter Size and Spacing 1.1 psf 2 x 6 @ 24 in. O.C. 1.1 psf Vaulted Ceiling 0.0 psf No 0.0 psf Miscellaneous 1.1 psf Miscellaneous Items 1.1 psf Total Roof Dead Load 10.0 psf 10.0 psf Reduced Roof LL Non-PV Areas Value ASCE 7-10 Roof Live Load Lo 20.0 psf Table 4-1 Tributary Area Reduction R1 1.0 Section 4.8 Sloped Roof Reduction R2 1.0 Section 4.8 Reduced Roof Live Load Lr Lr = Lo (R1) (R2) Equation 4.8-1 Reduced Roof Live Load Lr 19.5 psf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load pg 30.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? No Snow Guards to be Installed? No Snow Importance Factor Is 1.0 Table 1.5-2 Snow Exposure Factor Fully Exposed Ce Table 7-2 0.9 Snow Thermal Factor Structures kept just above freezing Ct Table 7-3 1.1 Min Flat Roof Snow (w/ Rain-on-Snow Surcharge) pf-min 30.0 psf 7.3.4 & 7.10 Flat Roof Snow Load pf = 0.7 (Ce) (Ct) (1) pg; pf >_ pf-min Eq: 7.3-1 pf 30.0 psf 100% ASCE Design Sloped Roof Snow Load Over Surrounding Roof All Other Surfaces Surface Condition of Surrounding Roof Cs -roof Figure 7-2 NA ps-roof = (Cs-roof) pf ASCE Eq: 7.4-1 Design Roof Snow Load Over Surrounding Roof ps-roof a / 30.0 psf 100% ASCE Design Sloped Roof Snow Load Over PV Modules vvIleatRidn� Unobstructed Slippery Surfaces; ding Surface Condition of PV Modules Cs -pv NA �"' JD Figure 7-2 9 ps-pv = (Cs-pv) pf ASCE Eq: 7.4-1 Design Snow Load Over PV Modules ps-pv 30.0 psf 100% Structural Calculations Package MP2A 9/26/2017 9:24 — " — v17.8 Member Design Applied Loads Type Magnitude Distribution Start Location End Location 10 psf Roof Dead Load Full Uniform Area 0.00 ft. 13.16 ft. Non -PV Roof Live 19.5 psf Partial Area 0 ft., 10.5 ft. 1.1 ft., 13.1 ft. Snow Load 30 psf Full Uniform Area 0.00 ft. 13.16 ft. PV Dead Load 3 psf Partial Area 1.1 ft. 10.5 ft. Member View Snow Roof Live Roof Dead PV Dead --= -- ! 14.10 13.16 9.91 0.99 Dead Roof Live Snow Wind Member Specs Lumber -soft, DF, #1, 1.5"x5.5" Member spaced at 24" c/c; Total length: 14.10' ; volume = 0.81 cu.ft.; Pitch: 4.5/12 (21 degrees); Lateral support: top = Full, bottom = At Supports Structural Calculations Package MP2A v1 7.8 9/26/2017 9:24 Analysis Results C Factors Load Combo CD CL (+) CL (-) CF Cr Cv CM Ct D 0.90 1.00 0.89 1.30 1.15 1.00 1.00 1.00 D+Lr 1.25 1.00 0.77 1.30 1.15 1.00 1.00 1.00 D+S 1.15 1.00 0.81 1.30 1.15 1.00 1.00 1.00 6D+.6W 1.60 1.00 0.64 1.30 1.15 1.00 1.00 1.00 DCRs (Critical Load Combinations are Highlighted) Load Max @ Location Combo Analysis Demand Capacity DCR Result D Shear 22.2 psi 10.6 ft 162.0 psi 0.14 Pass D (+} Bending 280.1 psi 5.1 ft 1345.5 psi 0.21 Pass C% (-) Bending -327.6 psi 10.6 ft -1196.3 psi 0.27 Pass r, Deflection 0.1 in 5.5 ft 1.0 in 0.07 Pass D + Lr Shear 22.7 psi 10.6 ft 225.0 psi 0.10 Pass D + Lr (+) Bending 259.5 psi 5.1 ft 1868.8 psi 0.14 Pass D + Lr (-) Bending -337.3 psi 10.6 ft -1436.9 psi 0.23 Pass n 1 i . Deflection 0.1 in 5.5 ft 1.0 in 0.06 Pass D + S Shear 70.1 psi 10.6 ft 207.0 psi 0.34 Pass _ - (+) Bending 877.3 psi 5.1 ft 1719.3 psi 0.51 Pass D + S (-) Bending -1038.1 psi 10.6 ft -1386.8 psi 0.75 Pass Deflection 0.2 in 5.5 ft 1.0 in 0.22 Pass .6D +.6W Shear 13.3 psi 10.6 ft 288.0 psi 0.05 Pass 6=% + 5-" (+) Bending 168.0 psi 5.1 ft 2392.0 psi 0.07 Pass .6D + ZV, (-) Bending -196.6 psi 10.6 ft -1537.6 psi 0.13 Pass I 6? -' + . 4 �V ). I Deflection 1 0.0 in 1 5.5 ft 1 1.0 in 1 0.04 1 Pass I Other Calculations C&, Deflection: EI = 35354688 Ib-in2 Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection °Nheat Ridge ` Lateral stabilityLu = 114.66 in. Le = 181.60 in. RB = 21.07 "ludding Qivison (-) Support Reactions Ext Wall Support 1 Ridge ---- ---- ---- Unfactored: Dead 122 lbs 247 lbs -25 lbs --- ---- --- Roof Live 49 lbs 46 lbs 60 lbs --- ---- --- Snow 2801bs 550 lbs -35 lbs ---- ---- ---- Wind 0 fbs 0 lbs 0 lbs --- ---- ---- Other Calculations C&, Deflection: EI = 35354688 Ib-in2 Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection °Nheat Ridge ` Lateral stabilityLu = 114.66 in. Le = 181.60 in. RB = 21.07 "ludding Qivison (-) Structural Calculations Package MP2B&3 9/26/2017 9.24 v17.8 Load Itemization Net PV System Load PV Module Weight 2.5 psf Net PV System Weight 3.0 psf Hardware Assembly Weight (psf) 0.5 psf Roof Dead Load Non -PV Areas Material PV Areas Original/Existing Roofing Material 5.0 psf Comp Roof ( 2 Layers) 5.0 psf Re -Roof (Under PV Assembly) No 0.0 psf Underlayment 0.5 psf Roofing Paper 0.5 psf Plywood Sheathing 0.0 psf No 0.0 psf Board Sheathing 2.3 psf Solid -Sheathing 2.3 psf Rafter Size and Spacing 2.3 psf 3 x 6 @ 24 in. O.C. 2.3 psf Vaulted Ceiling 0.0 psf No 0.0 psf Miscellaneous 1.4 psf Miscellaneous Items 1.4 psf Total Roof Dead Load 11.5 psf 11.5 psf Reduced Roof LL Non -PV Areas Value ASCE 7-10 Roof Live Load Lo 20.0 psf Table 4-1 Tributary Area Reduction R1 1.0 Section 4.8 Sloped Roof Reduction R2 1.0 Section 4.8 Reduced Roof Live Load Lr Lr = Lo (R1) (R2) Equation 4.8-1 Reduced Roof Live Load Lr 19.5 psf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load pg 30.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? No Snow Guards to be Installed? No Snow Importance Factor Is 1.0 Table 1.5-2 Snow Exposure Factor Fully Exposed Ce Table 7-2 0.9 Snow Thermal Factor Structures kept just above freezing Ct Table 7-3 1.1 Min Flat Roof Snow (w/ Rain -on -Snow Surcharge) pf-min 30.0 psf 7.3.4 & 7.10 Flat Roof Snow Load pf = 0.7 (Ce) (Ct) (1) pg; pf >_ pf-min Eq: 7.3-1 pf 30.0 psf 100% ASCE Design Sloped Roof Snow Load Over Surrounding Roof All Other Surfaces Surface Condition of Surrounding Roof Cs -roof Figure 7-2 NA ps-roof = (Cs -roof) pf ASCE Eq: 7.4-1 Design Roof Snow Load Over Surrounding Roof ps-roof 30.0 psf 100% ASCE Design Sloped Roof Snow Load Over PV Modules Unobstructed Slippery Surfaces Surface Condition of PV Modules Cs -pv Figure 7-2 NA ps-pv = (Cs-pv) pf ASCE Eq: 7.4-1 Design Snow Load Over PV Modules ps-pv 30.0 psf ° 100 /° iL Structural Calculations Package v17.8 MP2B&3 9/26/2017 9:24 Member Design Applied Loads Type Magnitude Distribution Start Location End Location 11.5 psf Roof Dead Load Full Uniform Area 0.00 ft. 12.09 ft. Non-PV Roof Live 19.5 psf Partial Area 0 ft., 7.4 ft. 4.2 ft., 12 ft. Snow Load 30 psf Full Uniform Area 0.00 ft. 12.09 ft. PV Dead Load 3 psf Partial Area 4.2 ft. 7.4 ft. I Member View - Snow Roof Live Roof Dead PV Dead - 12.95 12.09 0.16 Dead = -= Roof Live -= Snow - - in Member Specs Lumber-soft, DF, #1, 3"x5.5", w/ specified upgrades at Ridge Member spaced at 24" c/c; Total length: 12.95' ; volume = 1.48 cu.ft.- Pitch: 4.5/12 (21 degrees); gW►d+ngDivis,, Lateral support: top = Full, bottom = At Supports Structural Calculations Package MP2B&3 9/26/2017 9:24 �-- v17.8 Analysis Results C Factors Load Combo CD CL (+) CL (-) CF Cr Cv CM Ct D 0.90 1.00 0.98 1.30 1.15 1.00 1.00 1.00 D+Lr 1.25 1.00 0.97 1.30 1.15 1.00 1.00 1.00 D+S 1.15 1.00 0.98 1.30 1.15 1.00 1.00 1.00 .6D+.6W 1.60 1.00 0.96 1.30 1.15 1.00 1.00 1.00 DCRs (Critical Load Combinations are Highlighted) Load Combo Analysis Max Demand @Location Capacity DCR Result D Shear 12.3 psi 0.2 ft 162.0 psi 0.08 Pass (+) Bending 389.2 psi 6.6 ft 1278.2 psi 0.30 Pass D (-) Bending -0.2 psi 0.2 ft -1256.9 psi 0.00 Pass D Deflection 0.2 in 6.6 ft 1.3 in 0.16 Pass D + Lr Shear 25.7 psi 13.0 ft 225.0 psi 0.11 Pass D + Lr (+) Bending 683.0 psi 6.8 ft 1775.3 psi 0.38 Pass D + Lr (-) Bending -0.6 psi 0.2 ft -1729.1 psi 0.00 Pass D + Lr Deflection 0.4 in 6.6 ft 1.3 in 0.30 Pass D + S Shear 40.4 psi 0.2 ft 207.0 psi 0.20 Pass (+) Bending 1235.8 psi 6.6 ft 1633.3 psi 0.76 Pass (-) Bending -0.9 psi 0.2 ft -1595.5 psi 0.00 Pass Deflection 0.7 in 6.6 ft 1.3 in 0.52 Pass .6D +.6W Shear 7.4 psi 0.2 ft 288.0 psi 0.03 Pass (+) Bending 233.5 psi 6.6 ft 2272.4 psi 0.10 Pass (-) Bending -0.1 psi 0.2 ft -2186.4 psi 0.00 Pass Deflection 0.1 in 6.6 ft 1.3 in 0.09 Pass Support Reactions Ext Wall Ridge ---- ---- ---- ---- Unfactored: Dead 161 lbs 157 lbs - --- - --- Roof Live 174 lbs 172 lbs -- -- --- --- Snow 368 lbs 358 lbs --- ---- ---- ---- Wind 0lbs 0lbs -- -- ---- --- Other Calculations Deflection: EI = 68629681 Ib-in2 Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection Lateral stability (-) : Lu = 153.35 in. Le = 237.32 in. RB = 12.04 - Structural Calculations Package MP4 ��.71 - v17.8 9/26/2017 9:24 Load Itemization Net PV System Load PV Module Weight 2.5 psf Hardware Assembly Weight (psf) 0.5 psf Net PV System Weight 3.0 psf Roof Dead Load Non -PV Areas Material PV Areas Original/Existing Roofing Material 5.0 psf Comp Roof ( 2 Layers) 5.0 psf Re -Roof (Under PV Assembly) No 0.0 psf Underlayment 0.5 psf Roofing Paper 0.5 psf Plywood Sheathing 0.0 psf No 0.0 psf Board Sheathing 2.3 psf Solid -Sheathing 2.3 psf Rafter Size and Spacing 2.3 psf 3 x 6 @ 24 in. O.C. 2.3 psf Vaulted Ceiling 0.0 psf No 0.0 psf Miscellaneous 1.4 psf Miscellaneous Items 1.4 psf Total Roof Dead Load 11.5 psf 11.5 psf Reduced Roof LL Non -PV Areas Value ASCE 7-10 Roof Live Load Lo 20.0 psf Table 4-1 Tributary Area Reduction R1 1.0 Section 4.8 Sloped Roof Reduction R2 1.0 Section 4.8 Reduced Roof Live Load Lr Lr = Lo (R1) (R2) Equation 4.8-1 Reduced Roof Live Load Lr 19.5 psf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load pg 30.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? No Snow Guards to be Installed? No Snow Importance Factor Is 1.0 Table 1.5-2 Snow Exposure Factor Fully Exposed Ce Table 7-2 0.9 Snow Thermal Factor Structures kept just above freezing Ct Table 7-3 1.1 Min Flat Roof Snow (w/ Rain -on -Snow Surcharge) pf-min 30.0 psf 7.3.4 & 7.10 Flat Roof Snow Load pf = 0.7 (Ce) (Ct) (1) pg; pf >_ pf-min Eq: 7.3-1 pf 30.0 psf 100% ASCE Design Sloped Roof Snow Load Over Surrounding Roof All Other Surfaces Surface Condition of Surrounding Roof Cs -roof Figure 7-2 NA ps-roof = (Cs -roof) pf ASCE Eq: 7.4-1 Design Roof Snow Load Over Surrounding Roof ps-roof 30.0 psf 100% ASCE Design Sloped Roof Snow Load Over PV Modules Surface Condition PV Modules Unobstructed Slippery Surfaces "f0igure of Cs -pv 7-2 NA 11 L ps-pv = (Cs-pv) pf ASCE Eq: 7.4-1 Design Snow Load Over PV Modules ps-pv 30.0 psf 100% ® S L� Structural Calculations Package MP4 i v17.8 9/26/2017 9:24 Member Design Applied Loads Type Magnitude Distribution Start Location End Location Roof Dead Load 11.5 psf Full Uniform Area 0.00 ft. 11.79 ft. Non -PV Roof Live 19.5 psf Partial Area 0 ft.,9 ft. 0.8 ft., 11.7 ft. Snow Load 30 psf Full Uniform Area 0.00 ft. 11.79 ft. PV Dead Load 3 psf Partial Area 0.8 ft. 9 ft. Member View } Snow -� Roof Live u Q Roof Dead PV Dead 12.63 11.79 0.99 I Dead - Roof Live Snow - - —Wind Member Specs Lumber -soft, DF, #1, 3"x5.5", w/ specified upgrades Member spaced at 24" c/c; Total length: 12.63' ; volume = 1.45 cu.ft.; Pitch: 4.5/12 (21 degrees); Lateral support: top = Full, bottom = At Supports Structural Calculations Package MP4 9/26/2017 9:24 �- v17.8 Analysis Results C Factors Load Combo CD CL (+) CL (-) CF Cr Cv CM Ct D 0.90 1.00 0.99 1.30 1.15 1.00 1.00 1.00 D+Lr 1.25 1.00 0.98 1.30 1.15 1.00 1.00 1.00 D+S 1.15 1.00 0.98 1.30 1.15 1.00 1.00 1.00 .6D+.6W 1.60 1.00 0.97 1.30 1.15 1.00 1.00 1.00 DCRs (Critical Load Combinations are Highlighted) Load Max Combo Analysis @ Location Demand Capacity DCR Result D Shear 12.9 psi 1.1 ft 162.0 psi 0.08 Pass D (+) Bending 344.5 psi 6.8 ft 1278.2 psi 0.27 Pass D (-) Bending -9.6 psi 1.1 ft -1259.3 psi 0.01 Pass F: Deflection 0.2 in 6.8 ft 1.2 in 0.13 Pass D + Lr Shear 18.8 psi 12.6 ft 225.0 psi 0.08 Pass D + Lr (+) Bending 396.0 psi 7.3 ft 1775.3 psi 0.22 Pass D + Lr (-) Bending -24.4 psi 1.1 ft -1734.8 psi 0.01 Pass D + Lr Deflection 0.2 in 7.1 ft 1.2 in 0.16 Pass D + S Shear 38.3 psi 1.1 ft 207.0 psi 0.19 Pass _- _ (+) Bending 1026.9 psi 6.8 ft 1633.3 psi 0.63 Pass D + S (-) Bending -33.0 psi 1.1 ft -1600.0 psi 0.02 Pass Deflection 0.5 in 6.8 ft 1.2 in 0.39 Pass .6D +.6W Shear 7.8 psi 1.1 ft 288.0 psi 0.03 Pass r L, - -r ` (+) Bending 206.7 psi 6.8 ft 2272.4 psi 0.09 Pass 5D + .&V`, (-) Bending -5.8 psi 1.1 ft -2198.0 psi 0.00 Pass 6C + Deflection 0.1 in 6.8 ft 1.2 in 0.08 Pass Support Reactions Ext Wall Ridge ---- ---- ---- ---- Unfactored: Dead 192 lbs 151 lbs --- ---- ---- Roof Live 47 lbs 90 lbs --- ---- ---- ---- Snow 386 lbs 321 lbs ---- ---- ---- --- Wind 0lbs 0lbs --- --- ---- --- Other Calculations Deflection: EI = 68629681 Ib-in2 Wheat Ft,; Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection Buira;n Lateral stabilityLu = 138.82 in. Le = 216.40 in. RB = 11.50 o"'�Son Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Rafter Spacing Kzt 21° 24" O. C. Section 26.8 Framing Type / Direction PV System Type Zep System Type Standoff Attachment Hardware V-Ult Y -Y Rafters SolarCity SleekMountTm ZS Comp Comp Mount SRV S1.1 Spanning Vents I No Section 26.7 Roof Style Wind Design Criteria Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method Kzt Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 1 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Thb Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V"2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient U GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure U u -29.5 psf Wind Pressure Down down 16.0 psf X4Nrection Y4Nrection Maximum Allowable Standoff Spacing Landscape 72" 39" Maximum Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Maximum Standoff Tributary Area Thb 20 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -312 lbs Uplift Capacity Per Manufacturer T -allow 548 lbs Standoff Demand/Capacity Demand/Capacity DCR 1 57.0% X -Direction Y -Direction Maximum Allowable Standoff Spacing Portrait 48" 64" Maximum Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Maximum Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -342 lbs Uplift Capacity Per Manufacturer T -allow 548 lbs Standoff Demand/Capacity DCR 1 62.3% Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Rafter Spacing Kzt 21 ° 24" O. C. Section 26.8 Framing Type / Direction PV System Type Zep System Type Standoff Attachment Hardware V-Ult Y -Y Rafters SolarCity SleekMountTm ZS Comp Comp Mount SRV S1.1 Spanning Vents I No Section 26.7 Roof Style Wind Design Criteria Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method Kzt Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V"2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient U GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up p(up) -29.5 psf Wind Pressure Down down 16.0 psf b1T'4m X -Direction Y -Direction Maximum Allowable Standoff Spacing Landscape 72" 39" Maximum Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Maximum Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -312 lbs Cit Y of �? Uplift Capacity Per Manufacturer T -allow 548 lbs Standoff Demand/Capacity DCR 57.0% X -Direction Y -Direction Maximum Allowable Standoff Spacing Portrait 48" 64" Maximum Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Maximum Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -342 lbs Cit Y of �? Uplift Capacity Per Manufacturer T -allow 548 lbs Standoff Demand/Capacity DCR 62.3% Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Rafter Spacing Kzt 21' 24" O.C. Section 26.8 Framing Type / Direction PV System Type Zep System Type Standoff Attachment Hardware V-Ult Y -Y Rafters SolarCity SleekMountTm ZS Comp Comp Mount SRV S1.1 Spanning Vents I No Section 26.7 Roof Style Wind Design Criteria Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method Kzt Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 1 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V"2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient U GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure U u -29.5 psf Wind Pressure Down down 16.0 psf X -Direction Y -Direction Maximum Allowable Standoff Spacing Landscape 72" 39" Maximum Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Maximum Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -312 lbs Uplift Capacity Per Manufacturer T -allow 548 lbs Standoff Demand/Capacity DCR 57.0% X -Direction Y -Direction Maximum Allowable Standoff Spacing Portrait 48" 64" Maximum Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Maximum Standoff Tributary Area Tdb 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -342 lbs Uplift Capacity Per Manufacturer T -allow 548 lbs Standoff Demand/Capacity DCR 62.3% PV MODULE 5%16"x1.5" BOLT WITH 5/1.6" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK —� ZEP FLASHING INSERT ' (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW (2 1/2" EMBED, MINI (E/ RAFTER s1.1 STANDOFF Scale: 1 1/2" = 1' INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1)j LOCATION, AND DRILL PILOT HOLE. rATTACH FLASHING INSERT TO (2)I MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FL ASHING INSERT PORT, WHICH SEADS I(� PRSEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOPI (4j OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. City of Wheat Ridge wilding SK 1.2 PARTIAL SISTER RAFTER UPGRADE INSTALLATION NOTES: 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. 2. FASTEN (N) SISTER TO (E) MEMBER W/ (N) SIMPSON SDW 22300 SCREWS (IF 2—PLY) OR SIMPSON SDW 22458 SCREWS (IF 3—PLY), AS SHOWN AT 16" O.C. ALONG SPAN IN THE FASTENER GROUPING DETAIL SEEN ON THE FAR RIGHT. IF WOOD SPLITTING IS SEEN OR HEARD, PRE—DRILL WITH A �" DRILL BIT. • SISTER ALL (E) RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED. iki (E) RAFTER 550O�' (N) SISTER MEMBER CENTERED BETWEEN SUPPORTS (E) LBW 0SIDE VIEW OF PARTIAL SISTER S2 SCHEMATIC DEPICTION OF MP THAT REQUIRES UPGRADES NTS (N) SIMPSON SDW 22300 WOOD SCREWS (E) WALL OR (N) SISTER MEMBER CENTERED SUPPORT BELOW F BETWEEN SUPPORTS (E) RAFTER (E) RIDGE BOARD OR SUPPORT BELOW TOP VIEW OF PARTIAL LENGTH SISTER (E) WALL OR SUPPORT BELOW (N) SIMPSON SDW 22300 WOOD SCREWS (N) SISTER MEMBERS W Scale: 3/4"=1'-0" (E) RIDGE BOARD OR SUPPORT BELOW (N) SIMPSON SDW 22458 WOOD SCREWS — (E) RAFTER '-0" MIN. Aio, TOP VIEW OF PARTIAL LENGTH LAPPED SISTER NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER Scale: 3/4"=1'-0" SK 1.2 (cont'd) PARTIAL SISTER RAFTER UPGRADE 6" END DISTANCE 16" O.C. TYP.--.� 1 Y4r [(N) SIMPSON SDW WOOD SCREWS (E) 2x MEMBER (E) RAFTER (N) SIDE MEMBER 2x4/2x6 END FASTENER GROUPING 6" END DISTANCE 16" O.C. � r TAGG. 2 TYP. 'r 1)/2„ (N) SIMPSON SDW WOOD SCREWS — (E) 2x MEMBER mo' (E) RAFTER Scale: 1"=1'-0" --------------- (N) SISTER MEMBER 2x8 END FASTENER GROUPING Scale: 1"=1'-0" .I i 6" END DISTANCE 16" 0C �'STAGG. TYP �r (E) RAFTER 1)/2" -o 4)/4 „ I (N) SIMPSON SDW WOOD SCREWS (N) SIDE MEMBER (E) 2x MEMBER -- 2x10/2x12 END FASTENER GROUPING Scale: 1"=1'-0" ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL -LISTED POWER -CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY -RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN ECC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET -BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL �►�, ��"�/r�1� City of ��LOPUMT Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). �/Commuw Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR APPROVED kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC Reviewed for Code Compliance LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW NEUT NEUTRAL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. !�• q•%i NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE Mans .aminer Date OC ON CENTER UL -LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING The 6310'"`°10pennifWop `owoO/Pbmsp-ifKa""" P01 POINT OF INTERCONNECTION HARDWARE. m"tim'� beaan�fp a��oPW�Of —vi -bb" tQ Oq of Vie provrsiom of the IkWl+rq CO& or of Wry City Wdim—. lkrnNb PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE Wv5UMkvW'jecurtwotoviO1OfC01`°AC1N1eF'°""`""°ftheAW&V SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. `°d"°r wdifto es of C" be— S STAINLESS STEEL V STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT C .. 3R NEMA 3R, RAINTIGHT Sheet 1 COVER SHEET ` Sheet 2 SITE PLAN LICENSE GENERAL NOTES TYPE EC # 8041 1. ALL WORK SHALL COMPLY WITH THE 2012 IBC • Sheet 8 THREE LINE DIAGRAM ~ AND 2012 IRC. ;` 2. ALL ELECTRICAL WORK SHALL COMPLY WITH _ - - - Cutsheets Attached THE 2017 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR - - Y AHJ: Wheat Ridge - -- REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: XCEL Energy (CO) CONTAINED L A THE INFORMATION HEREIN q6 NUMBER:" CONTAINED SHALL NOT BE USED FOR THE JB -8029174 0 0 PREMISE OWNER: " ALISON ALI BRODY DESCRIPTION' "Ali" DESIGN: T OF ANYONE TESLA MOUNTING SYSTEM: INC., NORISOLAREDGE Alison Ali Brody RESIDENCE Matthew Ruck T 5 L SHALBENEL ITBE DISCLOSED ISN WHOLE OT ZS Comp V4 wFlashing-Insert 2885 GRAY ST 3.9 KW PV ARRAY � n PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: WHEAT RIDGE, CO 80214 THE SALE AND USE OF THE RESPECTIVE (13) TRINA SOLAR # TSM-30ODD05A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV. DATE PERMISSION OF TESLA INC. # SE3000A-US-ZB-U I COVER SHEET 1 9/26/2017 L[OZ/9Z/6 Z 31Va 133135 Lj"l 5 J. May}}DI/V Iona N963� S ,9T 8 T 0 3 My T = .8/T :ale:)S N N` Id ALIS O3HSd0 SI 1NIHM03 d01d31N1 aid 3dV S1NIA WonaOdd 1b3H 0 30N33/31d9 d01d31N1 NO NnN iinaN00 ®— d01d31X3 NO Nnd 11f1ON00 SNOIld00I330aNd1S C) NM0a nHS Olddd — �f d313W W31SJ,S Ad O31b'01a3O O S130VI ONINdVM V d31N30 OVOI Dl S13OVI V I3Mdd NOune1d1S1a0a SI30VI V X08 d3N18W00/N0110Nnr 00 SI3OVI ONINddM V 103NN00SIO 0d S130VI ONINdb'M V 103NNOOSIO 0a I DO S138dl ONINdb'M 2R 00SI0 0O 031dd931N1 /M N3183ANl ��I I30VI ONINNVM V N313VI ,,1111(1 (3) O V IV=l.J:3 I tioTS T :AdOJS albulyS ow00 :lvlI 31` V4 6LT :H1f1WIZd ,,VM d 6LT :H1f1WIZd bdW TZ:H011d J VMV TZ :H011d tioTS T :),HOTS albulyS dw00 :ldld31VV4 69Z:H1f1WIZ`d Avddv 69Z:H1f1WIZv EdW TZ H011d ,lddNV TZ :H011d /cols T :),dO1S albulyS dwo0 :ItlId31`dW 68:H1f1WIZV AVddV 68:H1f1NIIZd ZdW TZ:H011d JlVMV TZ :H011d N 00 co cr G7 Q NVId 311S 31NN 39Vd , Vbd V Ad Mei 6'� 30N341S3N AP0a8 ,!IV,, u0SlIV AVM3ARi0 (3) asnOH 10 IuOJ� V 1208 00 `30CIN ld3HM 1S ),Vdo 5882 J CIMEI „I]V,, NOSIlV :2GNM0 3SI1138d 30Nb'HO 3dnlondls 9S� ,£ Plan 9S� ,£ ® F --7 y \ \ mss\ I I N�'\ Iw x ''.9�\ I„ \ I\ fI—BZ—sn—`BOOMS # 300MVIOS 'DNI YM31 3o NOISSIW83d :a3 S&NI N31118M 3H1 1nmm '1N3rrMM VM31 [-V90a0002—WSl # d`dIOS dNldl (2l) 3n1103dS38 3H1 Ho 3sn ONV 31VS 3H1 531noom HIM N0003NNOD NI 1d3OX3 'NOILVZINV9210 JaSU bul SD M dw0 SLN31dID38 3H1 30S1nO SiGRIO Ol 18Vd I— 4 13 �� 0 SZ NI 80 310HM NI a3SOlOSIO 38 11 IIVHS :KHSAS 9NI1NnOM NON " ON1 V1S31 1d3DX3 3NOANV 30 IIAN38 OO 00 � L l 6 Z 0 8 -8 � 3131 H a3sn OJ 13 L—TIVI ON30UNOO �2D8NnN 801' NI32l3H NOl1VY1NOjNl 3131 — ltl11N30LiNOD /M v LL GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND ODS AT PANEL WITH IRREVERSIBLE CRIMP Panel Number: TLM1212RCU Meter Number: 2147540 Inv 1: DC Ungrounded INV 1 — (1) SOLAREDGE ## SE3000A—US—ZB—U LABEL: A — (13) TRINA SOLAR## TSM-30ODD05A.18 II)) TYPE EC # 8041 Inverter; 3000W, 240V, 97.5%d w/Unifed Disco and ZB, AFCI PV Module; 30&,270.6W PTC,40MM�Ik Frome,MC4,ZEP,1000V,Wht BckSht Overhead Service Entrance INV 2 Voc: 39.9 Vpmox: 32.6 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER 125A MAIN SERVICE PANEL �E E 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING MILBANK CUTLER—HAMMER 10OA/2P Meter Socket Disconnect 2 SOLAREDGE (E) LOADSSE3000A—US—ZB—U A B::: zqo� • Ll 20A/2P (El --p-- GND A 1 1 N -- ---- GND------------------------- -EGC/ GEC --- Dc, � N Dc- 1 DC, - - - - Dc- P 2 - MP 4: 1x1 I B EGC EGC- 1GND I I -— -—-----------—-----------—----- ------ ----- --- ---- --- - -� I N I I EGC/GEC - Z Z C'J GEC TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I 1 I I I I I I I 1 I Voc* = MAX VOC AT MIN TEMP POI (1 )GE / THOL2120 PV BACKFEED BREAKER20A/2P, 2 Spaces Breaker, Meter Socket; 200A, #6-350, Ringless A (1)MILBANK # U4801 -XL -5T9 �� PowerBox ptimizer,300W, ZEP, in MC4,out MC4 PV (13)SOLAREDGE P300-5NM4ZS D� - (2) G'7r" CopperLoad-Side - (3) MILBANK N K4977 -INT Tap Connector, xRoo // 100A, #12 - 1/0 AWG �(1)CUTLER-HAMMER # DG221URB Disconnect; 30A, 240Vac, Non -Fusible, NEMA 3R - (1)CUTLER-HAMMER k DG03ONB Ground/Neutral Kit; 30A, General Duty (DG) (1 ) AWG #10, THWN 2, Black (1 ) AWG /10, THWN 2, Red O - —(2)AWG- -- - - J #10, TH Wire, N-2 Gree Voc* = 500 VDC Isc = 15 ADC Ol c°D� (1)AWGX10, THHN/THWN-2, Green EGC Vmp =350 VDC Imp=11 ADC L -L IL�-LL(I)AWG #10, THWN 2, White NEUTRAL Vmp =240 VAC Imp=12.5 AAC (1) Conduit Kit; 3/4' EMT - (1) AWG #8, THWN-2,. Green EGC/GEC - (1 ) Conduit. Kit; . 3/4' .EMT City of W heat � r Rtdy � goilryn9 plV/S `l. CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: J B- 8 0 2 917 4 0 0 PREMISE OWNER: �� rr ALISON ALI BRODY DESCRIPTION: "Ali" DESIGN: BENEFIT OF ANYONE EXCEPT TESLA INC., NOR Alison Brody RESIDENCE Matthew Ruck T E— S L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 2885 GRAY ST 3.9 KW PV ARRAY r"1 PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH WHEAT RIDGE CO 80214 MODULES THE SALE AND USE OF THE RESPECTIVE - (13) TRINA SOLAR # TSM-300DD05A.18(II) SHEET: REV: DATE TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME INVERTER: PERMISSION OF TESLA INC. SOLAREDGE # SE3000A—US—ZB—U THREE LINE DIAGRAM 8 9/26/2017 00-1�Z16Z08-91 AOi;,Z = 3Jd1.l0A JNLLVd3d0 L 1'069 33N H3d 103NNOOSIO 0/V NV SI 13NVd 1V01y13313 NIVA NI MUSS HOW GA—MVB 31V1lOA01OHd 13MIS /111311 n --------------------- - - - - - � (S),lb MV _OIdllOAOlOHd _dd]OS 133NNOOSIO dal aNV 2131d3ANl lO3NNOOSIG ov 4S AeaE) S88Z :ssajppV - :NMOHS SV 431VD01 S1.D3NNODSI4 H.LIM siDd 10S JNIM01103 3Hl W02i3 C13I1ddns OSl`d SI JNIdlIna SIHl 012i3MOd Noi nvD LIOZ/9Z/6 6 AVG ; :� addOVld NVId 3iIS 31NN 30Vd V 1208 OO 30M IVIHM �dddd fid/ Mei 6 ��/ II \\IInis ��y/ d0 5882/ 30NIGIS3d APOJG ,!IV,, UOSlIV ^QOaB ,I]V,, N0SI1V :NDadWS3a :UNMO 3SIl13ad n-oz-sn-vooms # 39amvios :NM1 ANI 'ONI VIS31 30 NOISSI1483d N3111 M 3HL 1nomm '1N3Mdlnb3 V1S31 3n1103dS38 3H13o 3sn aNV 31VS 3H1 HIM NOtL03NNOD NI 1d30X3 'NOILVZINVO80 S.LN3Idl03a 3H1 30IS1nO SMH10 01 18Vd NI 80 TIOHM NI 03SO10SIO 38 lI 11VHS �N3HLNMOja3sn331 388ION 11VHS03N[V1N08 NI383H NOIIVri8OdNI 3H1 — 1V11N301JNOD (II)8l'vgoaaoo�—Wsl # dVIOS VNI& (�L) 's31na0N _ V "I S = 1 }aasul-6uiysDl� M �/� dU10a SZ �Dn� M@gjjDyy VEX / I 7 ( ��1N31SAS9NIlNnON 00 t L 1.6 Z 0 8 —a I 8nNnN 801 00-1�Z16Z08-91 AOi;,Z = 3Jd1.l0A JNLLVd3d0 L 1'069 33N H3d 103NNOOSIO 0/V NV SI 13NVd 1V01y13313 NIVA NI MUSS HOW GA—MVB 31V1lOA01OHd 13MIS /111311 n --------------------- - - - - - � (S),lb MV _OIdllOAOlOHd _dd]OS 133NNOOSIO dal aNV 2131d3ANl lO3NNOOSIG ov 4S AeaE) S88Z :ssajppV - :NMOHS SV 431VD01 S1.D3NNODSI4 H.LIM siDd 10S JNIM01103 3Hl W02i3 C13I1ddns OSl`d SI JNIdlIna SIHl 012i3MOd Noi nvD AWARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION AWARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Label Location: (C)(CB)(JB) Per Code: NEC 690.31.G.3 Label Location: (DC)(INV) Per Code: NEC 690.13.6 Label Location: (DC) (INV) Per Code: NEC 690.53 Label Location: (AC)(POI) Per Code: NEC 690.13.15 Label Location: (AC) (POI) Per Code: NEC 690.54 Label Location: (AC)(POI) Per Code: NEC 690.17.E Label Location: (POI) Per Code: NEC 705.12.D.2 Label Set AWARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. AWARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED Per Code: 690.64 Label Location: (INV) Per Code: CEC 690.56(C) Label Location: (DC) (INV) Per Code: NEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED City Of wheat Ridge ;!ding Divisor a (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection stnNNZOOSYV009L3S:I—nui M009L,oI) vn NNOOOSn-VX=3S Ned uois,ar. 0p-(" 'ZNNNZOOS n-V009L35:,a —'PA009Z I -J) ZNNNOOOSn-Vxxxx35 N/d ape,S anuanaylrl palels sanlen aq4 of 1-- 3ndu, R.1!w.I j-, a4,,,u, ag4'pasn a4 Aew a—,, lua„n-42iy y Irl ,.dd., a8p3,elos 1-1— aseaid 1a41 -'-A h1 Sn-VOobl l3S / Sn-V000013S / Sn-Vo09L3S / Sn-V00093S / Sn-V00093S / sn-VooB£3s / sn-V000£3S = , , - � O eDIJawd gTJON JOI SJOIJAAUJ OSBU BIBUIS sn a2palejos MMM V'IHV91119- VDIy3VHIAOS-A3Ayil1 13V9S,-Ai'.-SONVIHIHLN 1H, V�'VB-SiV V%!i titldVf DNVyj UVlI ANVW839-VOVNVD-V5I'l T'ZTJ ISNV 'elep opeitf onuanaJ — leuo4dp — uopellelsul false;:o} yJl!mS Ala}eS palqwasse-aad — Aluo uOlvanuoo JV/Ja '-IalJanu) aOelloA p3x13 uoyellelsul Aoopw pue 3oopin0 — ssala3(M jo lauaagl3 y�3noTyl uoµaauuoa lamolu) — OUIJ011llow lanai-olnpow u! -ding — la� DeJq paplAoad uo Ilelsul of Asea pue ly$!amlygll 'llewS — W86) A:)uanyja jouadnS — ZT'069 bTOZ J3N jo4 umopings pidea aJuelidwOD TT -069 TTOZ J3N JO} u04Jalojd llnq Jae polejOalul slaz(wpdo jamod yllm Tom of pauBlsap Alleai.4pads - suaalsAs palgeua aSp3.1eloS aol a:)ioy:) Isaq ayl v 0 :raj u, x,ierte, ��uQ11eM s3eaF. 9Z"Z �'dUaN�x � e SA-VOONlas / sn-b0000l S / sn-doo9L3s -v000giS / Sn-v000siS / sn-voo8£3S / sn-v000c3S eOIJOwd glJON JOJ ;aa:aanuj eseyd BIOUIS afip3JBIOS Jelos y£ VAIN g uouualoJd ......2uey x �a8'ueb (;,)alge)lene uOISJaA og- of 04-) 09+oI SZ / ObT� o; EL a3n;ejadwal8u4eJadp xeiN ulW V8P OS > a Si0N asn) up; (algeaaeldai 3asn) suej Iewa;w, pue uoµaanuoD lwn;eN Au!looD Iein;eN 91.. . ... � ...... �.... TOb / b'.88 . . . ... . .. .. . .. ..... . ... .. . � L'4Z / L'45 ..4u1fMS Alales yl!M Iy2!aM ....w .... .. .. .. 09Z x ST£ x SLL .... ., ., .. ._.. .. .. .. ........ b8i x STE x SLL / Z'L x S'ZT x S'0£ ..... ... .... .... (OxMx4) / 0I / S'OT x S,ZT x S"OE ya}IMS Alajes g;iM suOlsuawl0 - 9MV 9-4I s8w31s wnwwlw 9MV 9-9T / Z -T / a ueI n0 j / s8uu;s £-T /wnwwlw „b/E , ,4/E o;ndu / s2ul34s;o.. / az......a 'JMV £-8 / wnuiiuiw „b/£ 9MV 9-9I / wnuiiuiw ,b/E . a2ue3 9N\V / azis 1!npuoa Indlno JV SNOI1tl71d1:)3dS NOlIV11VISNI g ssela ST1aed DA SuolSslw3 . ..... .... . .. ... ...... ....... .. .. .. .. LbST3331 spaepue4s uopauuoj pug ZZZ VSD 86611n 8669T1n'VS itziln'T4LTln AlabeS 3]NVildWO:) OatldNvlS saA ZT'069 VIOZ AN – umopinyS pidey ........... .................... .............. .. .. ..... ............., ;oleuogdp .. .. ... ... ............. .... I'ZTD ISNV'ele0 8pe39 anuanay (leuoudo) aagOiZ'Iauwayj3'ZEZSd'S8bSH saaepalul uoueawnwwo� pal3oddnS S3un1V3j IVNO11140tl -AA - 4> - -- - - S'Z>.- --.-uoudwnsuoJ Ja,Mod Pw lgf'N % SL6 nObZ @� S L6 SL6 SL6 nObZ _ 86 86 SL6 AauapyT3 pa;y2laN\ DI nSOZ L6 A80Z @7 L6 % 86 86 86 E'S6 E'86 Z86 1. L'L6 y;31a�anul wnwlxe A1lnplSuaS In1009 uouaa;a0 uouelosl ;Ines-punoj9 ...... ...._..................... ... ... ... . saA ...... ... . . .. .. .... uouaa;o.. �.. a... aPV Sb ."_. ... . .. ... .. . I.I., 3ua—D ;ina3q ljoHS lndul xeW Vv AW 6 s of SIE norz s'si `Z 8T ET 56 Ie13ua��nJ lndul �xeW ASOZ 9 EE A80Z -D S'9T �... PA ...... .... .. .. nObZ (P) OSE / A8 OZ J SZ£ a2ellon lndul JO woN ...... a8eilon indul :Xe .. saA ...... . _ papunw2un 'ssai 3aw3oysu eel M osm OOSET 0SZOT 0OT8 os 19 0015 0SO4 (31S)JD Od JO LnwlxeA 1ndNl SaA- saA sploysa3ylalgejn2poJA3;unoJ'uouaa;ad2ulpuelsl'2uuo;luowh;llpn V T ploysa3y- IOj9 V SZ4 nObZ N� Z4 ZE SZ nObZ L7 iZ 91 SZi 3uaiInD;nd;np snonuyuoJ xeW Ln7 n80Z 84 nBOZ �7 4Z .....Z ...... H ........... .. ... ................... s 09 .. .. ....... S 09 -09- £ 65xew-'woN- wW Aauanbay Dy . .. ,. .. ., .. .. .. . DeA b9Z-ObZ-TTZ ;;l xepN-wON-•ww 02e110A lndlno DV DLA 6ZZ-SOZEST - _ xelN �woN �ulyg a8e;ion;nd}np DV VA navz(Ybssbt o00ZT AOVz orbs OSE8 0009 OSib OOE£ - - _ Indlno JamOd JV xew n80Z@ OOSOT n80Z 9 uov5 VA .. g 00VII A 009L 0009 OOOS O08E 000E Ind;no iamod DV IewwON A80 iV 0866 0966 111d1n0 sn-voovii3s sn-v-wwils SN-v009L3s sn-v00o93s sn-v000sis sn-v008£3s sn-vooms Sn-VOobl l3S / Sn-V000013S / Sn-Vo09L3S / Sn-V00093S / Sn-V00093S / sn-VooB£3s / sn-V000£3S = , , - � O eDIJawd gTJON JOI SJOIJAAUJ OSBU BIBUIS sn a2palejos MMM V'IHV91119- VDIy3VHIAOS-A3Ayil1 13V9S,-Ai'.-SONVIHIHLN 1H, V�'VB-SiV V%!i titldVf DNVyj UVlI ANVW839-VOVNVD-V5I'l T'ZTJ ISNV 'elep opeitf onuanaJ — leuo4dp — uopellelsul false;:o} yJl!mS Ala}eS palqwasse-aad — Aluo uOlvanuoo JV/Ja '-IalJanu) aOelloA p3x13 uoyellelsul Aoopw pue 3oopin0 — ssala3(M jo lauaagl3 y�3noTyl uoµaauuoa lamolu) — OUIJ011llow lanai-olnpow u! -ding — la� DeJq paplAoad uo Ilelsul of Asea pue ly$!amlygll 'llewS — W86) A:)uanyja jouadnS — ZT'069 bTOZ J3N jo4 umopings pidea aJuelidwOD TT -069 TTOZ J3N JO} u04Jalojd llnq Jae polejOalul slaz(wpdo jamod yllm Tom of pauBlsap Alleai.4pads - suaalsAs palgeua aSp3.1eloS aol a:)ioy:) Isaq ayl v 0 :raj u, x,ierte, ��uQ11eM s3eaF. 9Z"Z �'dUaN�x � e SA-VOONlas / sn-b0000l S / sn-doo9L3s -v000giS / Sn-v000siS / sn-voo8£3S / sn-v000c3S eOIJOwd glJON JOJ ;aa:aanuj eseyd BIOUIS afip3JBIOS Jelos Next -Level PV Mounting Technology '":SOlafClty ZepSolar Next -Level PV Mounting Technology �'t`SOlafClt�/ ZepSolar ZS Comp for composition shingle roofs Components Mounting Block Part No. 850-1633 Listed to UL 2703 Array Skirt Part No. 850-1608 or 500-0113 Listed to UL 2703 Interlock Part No. 850-1388 or 850-1613 Listed to UL 2703 Flashing Insert Grip Ground Zep V2 Part No. 850-1628 Part No. 850-1606 or 850-1421 Part No. 850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 i �pMPq l� Description PV mounting solution for composition shingle roofs e� Works with all Zep Compatible Modules COMP111 Auto bonding UL -listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Captured Washer Lag End Cap U� LISTED Part No. 850-1631-001 Part No. Specifications 850-1631-002 (L) 850-1586 or 850-1460 850-1631-003 (R)850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No. 850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM i* DC Wire Clip Part No. 850-1509 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product we each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 City of fore V h e at Ridge Vgu;lding piv;son .r sn Apaielas mmm 7c.,,. -..a - 'IN 7I a �1�1 c.. c. r,..-.: _..,'.. _.. -_� . .�...... ... ._ Ala}es JaigByaay pue Japelsul Jo} uMopings a2eiloA larval-ainpolN — 8uuoiiuow larval-alnpow 410A aaueuaiulew uoueJauag 1xaN — uopezil.in aaeds wnwlxew Jo} u8isap walsAs ?Iq!xalA — 8uipegs lepied of aaueJalol Suiinpepuew woJ; 'sassol yaiewsiw alnpow jo sadAi Ile soie8uiw — (%S'66) Abuahy4a JopadnS — ABJaua aJow %SZ of dn — 1alpeJq agl 42nagl papunoig ivawdlnba Jaziw.ido Jannod — sisoa 2uiiunow pue Jogel ;oou-uo sa:)npaJ - srnaos inogi!nA owe -i} alnpow of sagaeily — ia�aeJq wlalquedwoD daZ pagyuaD — sainpow pauaeJj anoo.lg daZ Ljj!m algiledwo:) d3Z-00Vd 'd3Z-00£d ea!aawd WON JOJ u0-pp`d alnpow w1algijedwo3 daZ - ioziwildo J8MOd GORMOS - Jejos ;ptleu�uins Yuu1s/saly,hlne;ap/sats/wo�aepa�elos'mmm��:dy14 ol,a;a, uoyew,o;ui Puizls eui,ls palfe>ap,ei lzl .................... _... ...................... ............ __ . . suOueivaup saA to sy18ua3 ivaJa}ll4 jo s2uuls lalleJed M .... (sn Hoo9Z.3S OSLZT 0009 OSZS _ ............. ...... ...................... 8ufjiS aad lamod wnwlxeA grim 0009) 0 ............ _ _ ..... . . OS SZ Sc (Sazlw4d0 Jarvmod) yl2ual 2uiaiS wnwixew ............. . . . 8T g _................................................. (sjazlwlid0 jamod) g12u91 11UHIS wnwluiA AO8v A8OZ 3AVM-0H Iz183183AN1 39a38V1OS 3SVHd 319NIS 3SVHd 338H1 3SVHd 338H1 3SVHd 319NIS V 9NISn N91S3a W31SAS Ad p-11, wu°mal°1,amod %s- of do to alnpow -alnpow a41 io ,amod Jls paletl o, ......./......• _ OOT 0.._... .._ Al,piwnHaAilelab d9 V6'U3N / 89d1 ........ 2ugey uo4aa10ld d. / D. 581+ Ob / 58+ Ob a2uey aanIeaadwal2ugejad0 ....... ii /w ,...._.................._.. _ . 6'£ / Z'T OE /s6,0 gl2uel as UN indin0.. ............ .........I........... ... .. ..... ..... .............:.... alggedwoD bDw'paleinsul algno0 joloauuoD lndln0 .......... .......................................... alquedwo� bow _.........,... aohauuoD indul ql / I 6'T / Ob8 91 / OZL (ladaejq 2uqunow pue saIgea 5uipnpul} Ig0laM .................................................. ui J ww LET x L6'S x S 80'1 x L6'S x S / SLZ x ZST x 8ZT (HxlxM 1a>laejq 2uuunow 2uipnpxa suolsuawlO /SExZslx8ZT ........................................•. ....... ._ ...... ...... _ ..... .. ul J ww LE T x TCL x S / S£ x 961 x SET 80'1 x TCL x S / S'LZ x 961 x 8Z1 (HxlxA lajae.lq 2u4unow 2uipnpul suolsuawl0 ........... �P^ .. .. . ... ............. I.... ......... .,.. ............... 0001 _ _ .... _ . .. oJelloA waisAS pamollV wnwixelW SNOIiV313133dS NOI1VllViSN1 saA SHol1 TbLiin (Aoics p ssep) 1-601Z9J31 A1ales ............ ... .. .............. ... .. ...... .... ..... E-9-00019031 `Z-9-00OT9O31 '8 ssel9 ST1Jed OOd .....,............ .................. .. . ....,........... OW3 3:)NVIldWOJ aBVONVIS DPA T .IazlLuRdo aamod jad a2E410A lndlno AiaieS (330 8317d3ANI 80 83183AN1 WON3 a3133NNOJSIa 837IWIldO 83MOd) A9aNVlS gmuna indino apn 09 a2e1jOA lndin0 wnwlxew DPd _.... __.._ S1 _.................... 1uaim:) jndlno wnwlxew (83183AN1 9NI1V83dO Ol a31J3NNOJ 83ZIWI1dO 83MOd) NOI1V83dO 9N18na indlfl0 II /uo2a1e0 a2eil01aano 886 AMa13l}13 Paly2laM % S66 AauaiD4�3 wnwlxew aPV E9'ZT S'Z1 1ua»nD indul :)(Iwnwlxew aPV 101 OT (:)sl) 1uajjn0 }lnanD 1_logS wnwlxew DPA 08 8 8b 8 a2ue8 2upelad0lddw . . ..... ....................... (aJnleaadwal P� OS gb lsamol le 00A) a2ellOA lndul wnwlxew alnlosgV M ............... _ OOb..... .... OOE ............ Jamod D0 indul Pa1e21 1ndNl (-Inp0W 11-96 19 ZL J01) d3Z-OObd (salnpow Ad lla:)-O9 Jo;) d3Z-OOEd d3Z-OObd eOIJawd PON JOd u0 -PPV 81nPON wialggedwoo daZ - aaziwildo aannod a6p3aeloS - jos sn Apaielas mmm 7c.,,. -..a - 'IN 7I a �1�1 c.. c. r,..-.: _..,'.. _.. -_� . .�...... ... ._ Ala}es JaigByaay pue Japelsul Jo} uMopings a2eiloA larval-ainpolN — 8uuoiiuow larval-alnpow 410A aaueuaiulew uoueJauag 1xaN — uopezil.in aaeds wnwlxew Jo} u8isap walsAs ?Iq!xalA — 8uipegs lepied of aaueJalol Suiinpepuew woJ; 'sassol yaiewsiw alnpow jo sadAi Ile soie8uiw — (%S'66) Abuahy4a JopadnS — ABJaua aJow %SZ of dn — 1alpeJq agl 42nagl papunoig ivawdlnba Jaziw.ido Jannod — sisoa 2uiiunow pue Jogel ;oou-uo sa:)npaJ - srnaos inogi!nA owe -i} alnpow of sagaeily — ia�aeJq wlalquedwoD daZ pagyuaD — sainpow pauaeJj anoo.lg daZ Ljj!m algiledwo:) d3Z-00Vd 'd3Z-00£d ea!aawd WON JOJ u0-pp`d alnpow w1algijedwo3 daZ - ioziwildo J8MOd GORMOS - Jejos Mono Multi Solutions THE Tinamount 60 CELL MONOCRYSTALLINE MODULE 275-305W POWER OUTPUT RANGE 18.6% MAXIMUM EFFICIENCY MODULE Maximize limited space with top -end efficiency • Up to 186 W/m2 power density -Low thermal coefficients for greater energy production at high operating temperatures 0^'+5 i/ i/, Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) POSITIVE POWER TOLERANCE In-house testing goes well beyond certification requirements PID resistant 100% EL double inspection Founded in 1997, Trina Solar is the world's leading comprehensive solutions provider for solar energy. we believe close cooperation with our partners Is critical to success. Trina Solar now distributes its PV products to over 60 countries all over the world. Trina Is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners. Comprehensive Products And System Certificates IEC61215/IEC61730/UL1703/IEC61701 /IEC62716 ISO 9001: Quality Management System ISO 14001: Environmental Management System IS014064: Greenhouse gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System ttsrLa to �A Tinasolar ®Certified to withstand the most challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load • 35 mm hail stones at 97 km/h LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty - 25 Year Linear Power Warranty 100% 97% Additiiao c 90% nal value from Trina Solar's linear warranty, 80% V Years 5 10 15 20 25 ■ Trina Linear Warranty Standard Step Warranty Trinamount 40/1.57 PRODUCTSPOWER RANGE TSM-DD05A.18(II) 1 280-305W DIMENSIONS OF PV MODULE(mm/inches) 992/39.1 Back View 11/0.43 samnsea�am [ L' umlmle n 35/1.3 (A -A) I-V CURVES OF PV MODULE(305W) to. qp-19➢NYhIL _ _ ru ` � sn �, 9p 0 1646 So m P -V CURVES OF PV MODULE(305W) iso 1000W/m' 300 _w 3 2ao rmw'no lro - so :awy m_ o is]p 3o 40 so volw9e(Vl FRAMED 60 -CELL MODULE ELECTRICAL DATA (STC) Peak Power Watts-Pwx (Wp)' Power Output Tolerance-Pmrx (W) Maximum Power Voltage -V -P (V) Maximum Power Current-Isvp (A) Open Circuit Voltage-Vec M Short Circuit Current-Isc (A) Module Efficiency 4 (%) STC: Irradiance 1000W/m'. Cell Temperature 25`C, 'Measuring tolemnte: ±3%. 275 280 285 31.4 31.7 31.8 8.76 8.84 8.97 38.7 39.0 39.3 926 9.35 9.45 16.8 17.1 17.4 Air Mass AM 1.5. 290 0-+5 32.2 9.01 39.5 9.50 17.7 295 32.5 9.08 39.7 9.55 18.0 S 305 32.9 9.28 40.2 9.72 18.6 �turc�m. -40-+BS°C Temperature Coefficient of PNAx Baner3are Maximum System Voltage 1000V DC (IEC) Maximum Power -Pa (Wp) 205 209 212 216 220 223 227 e 29.2 29.4 29.6 29.9 assn: mwlu0q Bae 30.4 30.6 6043 7.02 7.10 7.17 ', r•ouMliq Bok 7.35 7.42 iao-,nBae 36.0 36.3 36.6 36.7 36.9 37.1 37.3 Short Circuit Current-Isc (A) 7.48 7.55 7.63 992/39.1 Back View 11/0.43 samnsea�am [ L' umlmle n 35/1.3 (A -A) I-V CURVES OF PV MODULE(305W) to. qp-19➢NYhIL _ _ ru ` � sn �, 9p 0 1646 So m P -V CURVES OF PV MODULE(305W) iso 1000W/m' 300 _w 3 2ao rmw'no lro - so :awy m_ o is]p 3o 40 so volw9e(Vl FRAMED 60 -CELL MODULE ELECTRICAL DATA (STC) Peak Power Watts-Pwx (Wp)' Power Output Tolerance-Pmrx (W) Maximum Power Voltage -V -P (V) Maximum Power Current-Isvp (A) Open Circuit Voltage-Vec M Short Circuit Current-Isc (A) Module Efficiency 4 (%) STC: Irradiance 1000W/m'. Cell Temperature 25`C, 'Measuring tolemnte: ±3%. 275 280 285 31.4 31.7 31.8 8.76 8.84 8.97 38.7 39.0 39.3 926 9.35 9.45 16.8 17.1 17.4 Air Mass AM 1.5. 290 0-+5 32.2 9.01 39.5 9.50 17.7 295 32.5 9.08 39.7 9.55 18.0 300 32.6 9.19 39.9 9.64 18.3 305 32.9 9.28 40.2 9.72 18.6 ELECTRICAL DATA(NOCT) -40-+BS°C Temperature Coefficient of PNAx -0.39%/�C Maximum System Voltage 1000V DC (IEC) Maximum Power -Pa (Wp) 205 209 212 216 220 223 227 Maximum Power Voltage-Vwp M 29.2 29.4 29.6 29.9 30.2 30.4 30.6 Maximum Power Current-Ir,PP (A) 7.02 7.10 7.17 7.23 7.28 7.35 7.42 Open Circuit Voltage-Voc M 36.0 36.3 36.6 36.7 36.9 37.1 37.3 Short Circuit Current-Isc (A) 7.48 7.55 7.63 7.67 7.71 7.78 7.84 Noa rrmdance at 800w/m1, Ambient Temperature 20°4 wind speed 1 m/s. MECHANICAL DATA Solar Cells Monocrystalline 156.75 x 156.75 mm (6 inches) Cell Orientation 60 cells (6 x 10) Module Dimensions 1650 x 992 x 40 mm (65.0 x 39.1 x 1.57 inches) Weight 19.6 kg (43.1 Ib) Glass 3.2 min (0.13 inches), High Transmission, AR Coated Tempered Glass Backsheet White Frame Black Anodized Aluminium Alloy J -Box IP 65 or IP 67 rated Cables Photovoltaic Technology Cable 4.Omm' (0.006 inches'), 1000 mm (39.4 inches) Connector MC4 Fire Type UL 1703 Type 2 for Solar City TEMPERATURE RATINGS CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 2017 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are MAXIMUM RATINGS NOCT(Nominal om,ting cell Temperature) 44'C(i2°Q Operational Temperature -40-+BS°C Temperature Coefficient of PNAx -0.39%/�C Maximum System Voltage 1000V DC (IEC) Temperature Coefficient of Vm -0.29%/°C I OOOV DC (UU Temperature Coefficient of Isc 0.05%/'C Max Series Fuse Rating 15A (DO NOT connect Fuse in Combiner Box with two or more strings in parallel conn-mn). WARRANTY PACKAGING CONFIGURATION 10 year Product Workmanship Warranty Modules per box: 30 pieces 25 year Linear Power Warranty Modules per 40' container: 840 pieces (Please refer to product warranty for details, Trinasolar CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 2017 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are Wheat Ric';,, subject to change with t notice Version number. TSM -EN -2017_A svw City of Wheat Ridge Residential Roofing PERMIT - 201703165 PERMIT NO: 201703165 ISSUED: 07/03/2017 JOB ADDRESS: 2885 Gray ST EXPIRES: 07/03/2018 JOB DESCRIPTION: Residential Re -roof to install dimensional asphalt shingles - 18 sq. *** CONTACTS *** OWNER (303)842-9487 BARRETT BRETT *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,500.00 FEES Total Valuation 0.00 Use Tax 157.50 Permit Fee 172.60 ** TOTAL ** 330.10 *** COMMENTS *** *** CONDITIONS.*** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201703165 PERMIT N0: 201703165 ISSUED: 07/03/2017 JOB ADDRESS: 2885 Gray ST EXPIRES: 07/03/2018 JOB DESCRIPTION: Residential Re -roof to install dimensional asphalt shingles - 18 sq. I, by my signature, do hereby attest that the work to be perfonned shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performe� that X11 work to be Krfonned% disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or ONTRACTO (Circle one) Date I . This permit was issued base oration provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance orgr 'ng of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code any rdtnance o dont 's jurisdiction. Approval of work is subject to Held inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Dan Schultz �(703161J From: no-reply@ci.wheatridge.co.us Sent: Wednesday, June 21, 2017 3:05 PM CO To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Dane (� �C Residential Roofing Permit Application For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number 2885 Gray St Brett Barrett 3038429487 This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number 2885 Gray St Brett Barrett 3038429487 Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Repairs Unlimited, Inc Contractor's License 022046 Number (for the City of Wheat Ridge) Contractor Phone 7208980272 Number Contractor Email Address michelleh@repairs-unlimited.com Retype Contractor Email michelleh@repairs-unlimited.com Address DESCRIPTION OF WORK Are you re -decking the No / roof? Description of Roofing dimensional Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 18 material selected above? Does any portion of the No / property include a flat roof? If yes, how many squares Field not completed. on the flat roof? z TOTAL SQUARES of all 18 / roofing material for this project Provide additional detail house, shed here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 7500 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Michelle Hall Email not displaying correctly? View it in your browser. 3 WORK AUTHORIZATION .FOR REPAIRS AND DIRECTION OF PAYMENT DATE: 06/08/2017 CLAIM I#: 5002938002-1-1 05/08/2017 DATE OF LASS: INSURED: BRETT BARRETT ADDRESS: 2885 GRAY ST, WHEAT RIDGE, CO 80214-8123 Your Insurance Carrier FARMERS submitted a request to CCA Global Partners, Inc. and its affiliate Lionsbridge Contracting Group to refer one of their vendors to provide the following services: ® Perform the necessary services to mitigate further damages to the address listed above. IT Provide a reconstruction estimate. Ff Perform repairs as indicated on Your Insurance Carrier's estimate. • This does not constitute a contract for reconstruction services. Authorize Your Insurance Carrier to issue payment, less any remaining deductible, for mitigation and reconstruction services to CCA Global Partners, Inc. on my behalf. I/We ® Understand that Your Insurance Carrier will pay for repairs of damages covered by the policy. ® Understand that Your Insurance Carrier will provide me/us with a copy of the approved estimate. ® Will sign a Certificate of Satisfaction once all services are completed so that payment may be made by CCA Global Partners, Inc. to their assigned vendor for services completed. ® Understand that the deductible, and/or any non-recoverable depreciation, is my/our responsibility. • Understand that any materials upgrades that I/we request, additional work, and/or services that are not covered by Your Insurance Carrier, and are agreed to with a separate change order are my/our responsibility, an4are nqlsubject t p thefiY2�ear warranty that is backed by Lionsbridge. InsGred/or Insured/or Authorized Representative Date Date �Zkl 7 Date To be completed by program contractor — coordinated repairs under this claim may include. Structural Repairs Mitigation Flooring Roofing Textiles/Clothing Other Repair State Date: l / Time: am pm Estimated Completion Date: 01 Ing CCiOF 10C },yt can xis 11 0 N S 11 R I l? G I �> CON x�! 1 RAC �,+ T- 0 It � n k N* i ' dt"Y OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:�- Job Address: fs' st Y A� i Permit Number: 2. 0 3 9 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes ' N9,/ When corrections have been made, call for re-inspec 'on al 303-234-5933 Date: l ' —Inspector: .� DO NOT REMOVE THIS NOTICE 3011ON SIHIgAOhVghf ION 00 :joloadsul :ale(] rE-6q-t,E,7,-E0C le uo►joadsupej joi livo lapow uaaq aAeq suqiioajjo.? uaqM. ON uoiloodsul-ad INd/INV E)Wlj :uoiloodsui jol 9jqej!leAB EWO ON r Gt :jaqwnN-,41WJGd /S- :ssejppV qor oo -2 py ;GdAiL uoi;oodsul 331ION N01133dSNI XO -4 6E69 -20E (EOE) - i9q/ _40 CCRE-.go,7 (EOE) aLqj uqijoadsul COSITZ (COC) U01SIAla uoli3edsul Buipl!ng 39aibi jmipwk*p. Apo Vill - i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: U + Job Address: Permit Number: 7��7u �lll ❑ No one available for inspection: Time -V' yM/PM spection required: Ye '' No *When corrections have been made, call for re -inspection at 303-234-5933 ( /1 Date: -(i//'4 + Inspector: IL DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Y `_U_ F Job Address: Permit Number: r ❑ No one available for inspection: Time / + 'A /PM fi- nspection required: 'Ye ' No --4When corrections have been de, call fo re -inspection at 303-234-5933 Date: Y e 5 I/% Inspector: K/�_ DO NOT REMOVE THIS NOTICE It � A i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: T Job Address: 6,jZ/1y' S Permit Number: 7 / ` 3 j K-' ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes(,/No/ When corrections have been made, call for re -in sp ction at 303-234-5933 Date: `-f, Inspector: DO NOT REMOVE THIS NOTICE I FOR OFFICE USE ONLY I Maljfnq°AO � (if different than property address) Address. C contractor: V-, C Ott P, Electrical: Plumbing: Mechanical: WR City License # WA City License # W, R, City License # Complete all information on BOTH sidei of this form FIN II'll ►• 3 . k � ,, vv q, Ft/LF Btu's Gallons Amps Squares tither o H '0 0 no i x 0 m r m ' z m m -C -Pl. F� CJl F" Cn INSPECTION RECORD Occuoancv/Tvpe INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. Plumbing I ECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete O Z Encased Ground Building Final Reinforcing or Monolithic Fire Department Weatherproof/ French Drain Sewer Service Lines Parking & LandsCaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. " * NOTE. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A Water Service Lines OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. /1.. u _ CONCRETE SLAB FLOOR Electrical ROUGHS Sheathing Lath /Wall tie Mid -Roof Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical POUR No CONCRETE UNTIL BE Insulation Drywall Screw FINALS Electrical Plumbing Mechanical Roof O Z Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & LandsCaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. " * NOTE. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTEAUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. /1.. u _ vL.%,Ur1A1M%,T IMUI f EkMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER � \ � »2 � »— doN one vlabr umG«Gr¢m y .. ( Re-inspection required: /r s \� §y .: Wh % r a been made, c for re-ins o Date: np c r � ? d DO NOT REMOV THIS " 1 City of Wheat Ridge 1� Residential Roofing PERMIT - 101991 PERMIT NO: 101991 ISSUED: 08/18/2010 JOB ADDRESS: 2885 GRAY ST EXPIRES: 08/18/2011 DESCRIPTION: Reroof 18 sqs with OC Durations shingles * ** CONTACTS * ** owner 303/238 -4966 Delores Saindo sub 303/465 -1728 Scot & Jade Sund 02 -1435 Viking Roofing Inc. ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0532 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 6,013.00 FEES Permit Fee 156.75 Total Valuation .00 Use Tax 108.23 ** TOTAL ** 264.98 m Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Midroof inspection is not required on permits purchased after 4/18/10. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other ap c b . Wh at Ridge insures, for work under this permit. Plans subject to field inspection. Signature of &ntractor/ownerP date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty -four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review i subject to field inspections. Signature o Building official date INSPEO ON REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUES S MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. oF " 9 City of Wheat Ridge Building Division y m 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 235 -2857 Inspection Line: 303 - 234 -5933 CQ ORADO Building Permit Application Property Address; 2Sti5 &ray 61r Date: Plan #: Permit #: Property Owner (please print): D eAortS Saindo Phone: 303.235 • L-t9Clr< Mailing Address: (if different than property address) Address: Same City State, Zip: Co BDZfq contractor: \16411-1 R MCI Contractor Lice nse #: IXQ4 Phone: 3p3• Nth 1 t28 Su[i1 -1 1 ractorsi: ,v.. _. Electrical City License #: Plumbing City License #: Mechanical City License #: Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): (ZG5i4CACf— construction value: $ 0 13 DQ�Criptl0l`�,4ttWO�'�( (2GROtJ (as calculated per the Building Valuation Data sheet) 1/o exf shh9 3la10'5 T10t,K {v deck Plan Review (due at time of submittal): $ (Y15{u11= GG bkraiivYl C3oYr (Ip� 5Q * m color'. W"*— Sq. Ft. /L.Ft added: Squares BTU's _ Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans suNgettaiald nspection. CIRLCE ONE:: (OWN (CONTRACTOR or PERSONAL REPRESENTATIVE f (OWNER) ( CONTRATOR) PRINT NAME: 1+<i°li J 9m SIGNATURE: {- �.1noL� SO✓1 _ Date: 1 8EPAFlTM-=NT PLANNING A P DEVELOPMENT Building Permit Number: 5757 BUILDING IN PECTION DIVI ION - 235-2855 CI OF WHEAT . GE Date: 8/28/97 750 WEST 29TH A NUE W T RIDGE, CO 0215 ! Property Property A T Contractor Licen No.: 18320 Co ,pany: Air Flow He ng Co. ! Phone: 477-1638 Phone: 477 1638 OWNER/CONTRACTOR SI ANDING AND AGREEMENT DATE Construction Value i: Permit Fee !: Plan Review Fee ': USe Tax ; Total: $2,452.00 $75.50 $0.00 $29.42 $104.92 I hereby certify that !he :setbsQi< PlOP"",, by and do not violate lIPplli:sbIe 0 .. rules or regula covensnts, essemenl8:pr re of re<:or!l; thst aU rnacle ore accurate; thst I have and agree to sblde application, and lh81.1 allSume fU","pOnsibllity for Code (U.B.C.) an,bnQ!her lIPP bIe Wheat RIdge ord (OWNER)(CONTRACTbR) SIG ED permit aDDlfcation are accurate, of the l::'ity of Whest Ridge or urements shown, snd sll8g81lons " conditions printed on this . with the Wheat Ridgs Building ceo, for ",0Ik under this permit. Description: REPLA E A1C i BUlL NG DEPARTMENT USE ONLY SIC: Sq. Ft. : Approvill : Occupancy : Walls: Roof: Stories : Residential Units: m (S) License No : Mechanical License No : Company: Electrical License No : Company: Expiration Date: Approval: . Expiration Date : Approval : . (1) (2) (3) lcrth In yQpur &pIllIcstlon snd 18..._ to the lows or the Stslll of CoIorsljo. snd to the Zoning any olhor sppIIcsbIe ordinances or the City. need within sixty (60) dsys from 18800 _ or (8) the building auth~ I8IU8pOl1ded or or_the smount IlOITIl8ily IOqUlnod. pn>Yided 110 chsnges have _ orwiU be made In tho ndonment has not exceeded one (1) year. If changes are made or If su~sk:m or abandonment now or wstor causing s drainage problem. ) ho....1n _ for a1llnspocllons snd 8h8U rocoIvo wrilIon opproY8l on in~ cord before bona.shall not be construed to be a permit for, nor an appnMd of. any YiotBtion of the provisions ulallon. C4 10 ONLY WHEN NED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5 3 24 HOURS PRIOR TO INSPECTION . DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DI ISION - 235-2855 CITY OF WHEA RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: Sl13lcr7 Property Owner: 1\\ b, ~ Property Address: c)885 Contractor License No. : I 'OJ ~ Company: f\ \ ( flo ~\O(\ ~tfee+ ILc.J0~'OtCLCO Phone: 411-\103 5 Wcthny tDl11fClny Phone: OWNER/CONTRACTOR SIGNATURE OF UNO RSTANOING AND AGREEMENT Construction Value: DlL\'3aC{) Permit Fee: l[~ '5U Use Tax: "",fJ Y:L I hereby certify that the. setback distances proposed b this permit application are accurate, and do not violate applicable ordinances. rules or regu ations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown. and allegations made are accurate; that I have read and agree to abid by all conditions printed on this application, and that I assume full responsibilrty for co pha with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge or in ces, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE_t1 \2l \en Oescnption: l' Total: IQj'12.. BU LDING DEPARTMENT USE ONLY Approval: . J . d'd,~ ~'.d W, iw Approval: Occupancy: Walls: Root: Stories: Residential Units: Electrrcal License No : Company: Plu bing License No . Co pany: Mechanical License No : Company: Expiration Date: Approval: ~ Prllns,Rlllu~I'lld.",~] Expi ation Date: App oval: .JI P"l11!Re Expiration Date: Approval: :I !~;mrqull1lld This permit was ISSUed In accordance with the prOV1S1 ns set forth in yopur application and IS subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of lJIIheat Ridge. Cole 00 or any other applicable ordinances of the City. This permit shall expire If (A) the work authorized IS n t commenced within sixty (60) days from Issue date or (8) the building authonzed is suspended or abandoned for a. penOd of 120 days. If this permIt expIres. a new permIt may be acquired ~ r a fee of one-half the amount normally required. provided no changes have been or will be made in the original plans and Specifications and any suspenSion r abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year. full fees shall be paid for a new ermlt No work of any manner snail be done that will change tne natural flow of water causing a drainage problem. Contr ctor shall notify the BUIlding Inspector twenty.fo r (24) hOurs In advance for all InspeCtlons and shall receive written approval on inspectJon card before pr diing with successive phases of the Job. f1 ~~~Of a permit or the pproval of draWings no specifications shall not be construe<' to be a permit for. nor an approval of any violation of the provisions of eJJ g codes oc oy 0 ,"aoco. law. rule oc cegulal'oo (1) (2) (3) iet Building Inspector For Mayor THIS PERMIT VALID ONLY WHE SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234- 933 24 HOURS PRIOR TO INSPECTION r..T-- r BUIL~ING DEPARTMENT (303) 235-2855 CITY OF WHEAT RIDGE * * Correction Notice ~ . Job Located at 22 g:; G Y'19{ s;:- I have this day ins~ected this structure and these premises and have found the follo~ing violations of City and/or State laws gov- erning same: ( '.5(->> L 2' 5C/11 t.. cuf /2... ool~ Vt4//t.' -r; 11 c-. 'L. <; You are hereby !notified to correct the foregoing violations. When corrections hlllve been made, call for inspection. Date 1> ~ I~ FOAM WR8-22 [ , I.o",._":;:o-._.~-,-,._. /1 1(~~lS ~,/_., // . . -' Inspector for Building Dept. DO NOT REMOVE THIS TAG '? i ~""""~I"",~""""'r'-'~.'"~'!111!"'~"'1.k,.""",.".,,,,,.~.~r',~"'Mt..".",....""""',..~_.""..."""'~".......,...",I",.."",~.\ ....,.~ A~D DEVELOPMiNT Building Permit Number: 95~ 1675 .;:' .' .'. '.. . oJr~lEAor'& - 236-21&5 Date :8/18195 ,.. . ~ WI6T 29TH AVJ:NUE . . TAlDGE, CO 80215 -;'; flropertyO'Nner: SAINDON EQMOND L p~ AdCItess: 2$85 GRAY ST Col\tral::tOrLicenseNo.: 18457 Company: B & B Sprinkler Phone :238-49$6 Phone: 936 8253 ~~CT6R$~NATURE OF UNDERSTANDING ANOAGRE~eNT I ~ttia\~~""'PrOpo8lldbr Ihill1P!'rmIt ~Uestlcln alii aocurate. ~.i...E..". E...... ......."..I~~~.,t..18'91-..M;..;~'.'=".=..:w...~~,. H,....~~~lfw~.~~~"t.=onl!llli .... (:a.e;)*IlCI.t1I~.~1 ~re W!MIal Idge ~~c;.. folwork Undei'=lr~ (~)$lG/'~'r~rrr)tr~.. DAn=Y-/9'-9-7 ~ :'. 'LA~RINKLER SYSTEM. OUTSIDE TAP BUILDlNG DEPAR'TMEN1 USe ONLY II. ConslrllctionValue: Pem'1itFee : Plan RevIeW Fee : UaeTax: Total: $2.020.00 $54.00 $0.00 $30.30 . ".30 ~'",', ". .. ,- .. '.' . , ,. . .' .' . .: . .~: ZonIng : . Approval: 0clctJpaQcy : Walls: Roof: Stories : Residential Units : .. .J' . ~L~No: ~: Plumbirl,gLlcen$e No: company: MechanlcaI iJcense No : Company: ExpltaIion Date : Appro\,aJ : To', .'" Expl~ Date: Approval : . Expiration {)ate : Approval: ;'-"T':' ""-',:['; (1) '~~"=~~wf::~t:::r:-~~=~_ctthe_ct~snd"""ZonInG (2l ~~Jo""~ IS net ""!"''''i<:od_ 8bcIy(llO)doYt__d8loor(B)1lO buIIdIng_lSlUlIpOndedor (3) IIIIa ~ln8Ybeocq&JlNllfor~r=Ihe_~IlIqU/nld._nodlongoahOW_orWlllbe_1n1he '~l'l:I:lIiIlI . _.~. hsanet_Ol\8(!t)year. lfdlsng.....madaor._I8fOI'or._.oant (4) '=dl:(l).~'!iil!!l!"~WlllCI18nIl!l __or_csualna'.~~ (5) 'II! r~Wo~ -'Y:ftlurl2l4)_In_loraU~ai1cl_____,,"InIpeclIonCl/d_ !!BtliW:..... the Job, (8) ~"a or.....__ofdrawlngs8nd~. ahsIl net be _ II> bea pOrmItfor. nor *' ~or. arrr- orWoplOVlalona , :::rc7A/d~' , 8Ul1d1tlg I~ tft~ PMIItf~~:<t~yJt~ =~::~loClflrp~G ~CTOR . If~~7D DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: Property Owner: /vi f 5"'1 ,y/ dC4r/ Property Address:;2. 9' ~:.f 0/>""1 5'" Contractor License No. : I '( i 5 7 Company: !) I/)'5 f'riv? /: fA y Phone :7( ~ 6 'i- '" ",,-'7,/,,{6 r- ?_ Phone: 'Y3 G - irJ S--5 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: ;:z 0 ~o Permit Fee: e<- - I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown. and allegations made are accurate; that I have read and a9ree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRAC;:OR)SIGN.ED ~ '1.//7 ~ OATE7f.;:t-95 Description: / i"Q ,c:?:, ,.., , fL' _ '." _ :,_f~) ',C _ Ac,~ ~-c..... LL <;::::;)___-____/..._4_~<_/ -- 'y d-..... "'::1 ~,-,_ L/ Use Tax: Totai: (,;. ? ./ BUilDING' EPARTMENT USE ONLY Approval: Approval: Occupancy: Walis: Roof: Stories: Residential Units: Electricai License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: .:.I !p!!flm!~JmmII'~[j Expiration Date: Approvai : ill lE~'IlY!!'i!!1 ,d Expiration Date: Approval: 1III,__u'_"'". (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning RegulatIons and Buildln9 Code of Wheat Ridge, Colorado or any other applicable ordinances of the CIty. This permit shall expire If (A) the work authonzed IS not commenced wlthm SIXty (60) days from issue date or (S) the building authorized is suspended or abandoned for a period of 120 days, If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the anginal plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. N'o work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shalt receive written approval on inspection card before proceediing with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of. any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING A D DEVELOPMENT Building Permit Number: 95-1339 BUILDING INSPECTION DIVI ION - 235-2855 CITY OF WHEAT RI GE Date: 7/6/95 7500 WEST 29TH A ENUE, WHEAT RIDGE, CO 0215 Property Owner: SAINDON E Property Address: 2885 GRAY Contractor License No.: 17152 Company: Precise Plum ing OWNER/CONTRACTOR SIGNATURE OF UNDER TANDING AND AGREEMENT I hereby certify that the setback distances proposed by this ermit application are accurate, and do not violate applicable ordinances, rules or regulations of t e City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements 5 own, and allegations made are accurate; that I have read and agree to abide by all condition printed on this application, and that I assume full responsibili!y for compliance with the VVheat Ri ge Building Code (U.B.C.) and all other applicable V'vtleat Ridge ordinances, for work under thi permit. (OWNER)(CONTRACTOR) SIGNED Description: REPLACE WATER HEATE DATE Phone: 238-4966 Phone: 5340881 Construction Value: Permit Fee: Plan Review Fee: Use Tax: Total: BUILD NG DEPARTMENT USE ONLY -i!i~~1 Db;:m~..", " , ,.;::;,;:;:,::;:;::;,.,,;::;~ Approval: Zoning: -i\;l!il'iWI~"i!lnmsM ~~~!!!!'~...:::'~:::;~mm:;:;~:;w;:;:;~~:;~~~: Approval: "flJ.r;3!!@g1l1t[:~~~I::n'~f. Approval: Occupancy: Walls: Roof: Electrical License No : Company: Plumbi g License No : Compa y: Expiration Date: Approval: llll!mlla""":~11'iHMP """.....,., ",:,..llL.. '.',". '0""".",] Expirati n Date: Approv I: ::,t." ..,', "!I.......' "". w~., .; .~ ~ ~~~ .muu~ Stories: Residential Units: Mechanical License No : Company: Expiration Date: Approval: "J.WMit.:J*i1.t1~ill $373.00 $15.00 $0.00 $0.00 $15.00 This permit was issued in accordance with the provisions et forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Buildin!;! Code of V\lheat Ridge, Colorado r any other applicable ordinances of the City. This permit shall expire If (A) the work authorized is not co menced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a e of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or a andonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new per it. No work of any manner shall be done that will change the atural flow of water causin~ a drainage problem. Contractor shall notify the Building Inspector twenty-four ( 4) hours in advance for all Inspections and shall receive IM"iIIen approval on inspection card before proceediing with successive phases ofthel'ob. The' uance 0 a permit or the approval 0 drawings and pecifications shall not be construed to be a permit for, nor an approval of, any violation ofthe pr IS' ns of building c es any other ordinance, la ,rule or regulation. (1) (2) (3) ~~l (6) THIS PERMIT VALID ONLY HEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-59 324 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING ~ND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: Property Owner: C. ;; p ;n c1cn Property Address: :J. s-S-- ,.;- {;,v'/ c;-c' Contractor License No.: / /j / 'i' 2- Company: ;:}'pc ;$(' /Z'H t, "-'/ 'I"c Phone: :2 3 ~--L,/f'CC Phone: 7 }f-CJ ,'0 ir';' OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Use Tax: ~ /1 :f ~::;;z.- ,.7 I- I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance With the Wheat Ridge Building Code (U.B.C.) and aU other applicable Wheat . ge ordinances, for work u~r this permit. (OWNER)(GONTRACTOR} SIGNED ~;-? .,....;% ..........~~DATE /,,- ~ 5".p~?,r ':> Total: /5" - Description: c:,/ A' <' ~ C -<: <>,:/.:J(<"',r /,,..?' '-(_NO- BUILDING DEPARTMENT USE ONLY Approval: Zoning: Approval: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: App'Ova! : ]I J"PJaU~JtiidmlIIll Expiration Date: Approval: 1III" ~,' ,8"iiIIII.::',;':1 N . "^^& .....-/._ Expiration Date: Approval: ... "p-,- .. \'Mr~~--~.;;~ (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning ReJdulationS and Building Code of Wheat Rid\1e, Colorado or any other applicable ordinances of the City. This permit shall expire If (A) the work authorized IS not commenced Within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a penod of 120 days. If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the onginal plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspenSIon or abandonment exceeds one (1) year. full fees shall be paId for a new permit. N'o work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job The Issuance of a permIt or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation (1) (2) (3) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: 95-1294 Date : 6/26/95 Property Owner: SAINDON EDMOND L Property Address: 2885 GRAY ST Contractor License No.: 17814 Company: James Dye Construction Phone: Phone: 274 6718 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Use Tax: $1,500.00 $35.00 $22.50 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City ofVVheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate, that I have read and agree to abide by all conditions pnnted on this application, and that I assume full responsibility for compliance with the V\n1eat Ridge Building Code (U~C) nd all other applicable VVheat Ridge ordinances or ark under thiS ermlt " ( (OWNER)(CONTRACTOR) SIGNED \ '1 l/ ' DATE tlf U Description: REROOF $57,50 Total: BUILDING DEPARTMENT USE ONLY BmD~IiJ;;;]ELl1t1M Approval: Zoning: I..IB~;;JJ;~;@ Approval: rtAaq.I.1~'.Dl~:i Approval: Occupancy: Walls: Roof: Stories: Residential Units : Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: ''t'!SI'IIV''''W'Il-'%ilkl!' :L'-~::l!~".w.,~~ ~~';<'.N.')' .W.......NN.......==="- "- "-'AWU'..'....^",.~. Expiration Date: Approval: &!IIIIIEIWQ!I!lMiMl Expiration Date: Approval: gl"III..~mH@ This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code ofV\lheat RidQe, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorIZed is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causinfl a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all Inspections and shall receive written approval on inspection card before proceediing with successive phases ofthe;"ob. The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or an other ordinance, law, rule or regulation. )/L :,~ k-l f Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION (1) (2) (3) (4) (5) (6) Ifzl~] DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: MfJ-,'fMI<S .SA //v()&N Property Address: :~i}~6 r2.rt y S T I Contractor License No.: / 761 Y Company: :r/r\./( f) '/1 ('cJ N'/'r Phone: Phone : .~/ y: --6 //!1 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Use Tax: 1/:> c c) 3 S 07) ;;J,;J,:.0 S, 7 ,S7 I hereby certify that the setback distances proposed by this pannit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown, and allegations made are accurate; that I have read and a~ree to abide by all conditions printed on this application, and that I assume full responsIbility for comphance with the Wheat Ridge Building Code (U B C) and all other applicable ~ alf'dge ord''1ances. !orwork undertp~'1 (OWNER)(CONTRACTOR) SIGNED I .' / DATE ~ Descnptlon . Total: Approval: Zoning: Approval: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electncal License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: ill!I !ll.f!!IIIII!'-~ Expiration Date: Approval: ~ ~1IDs'~'.:i .1 Expiration Date: Approval: .111 '-"'-~I (1) (2) (3) This permit was issued in accordance with the provIsions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes halle been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or If suspension or abandonment exceeds one (1) year, full fees shall be paid tor a new permil. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with ,successive phases of the job. The Issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (4) IS) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION