Loading...
HomeMy WebLinkAbout3305 Harlan StreetFrom: no-reolvCalci.wheatridae.co.us To: CommDev Permits Subject: Online Form Submittal: PERMIT APPLICATION Electrical Service Change/Upgrade/Electrical Work Date: Wednesday, June 15, 2022 3:22:11 PM CAUTION:This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Report any suspicious activities to the IT Division. PERMIT APPLICATION Electrical Service Change/Upgrade/Electrical Work This application is exclusively for RESIDENTIAL ELECTRICAL SERVICE CHANGE OR UPGRADE (200 amps or less). YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes electrical service change or upgrade - 200 amps or less? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 3305 N Harlan St Property Owner Name Eric Bergman Property Owner Phone 402-630-0377 Number (enter WITH dashes, eg 303-123- 4567) Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 3305 N Harlan St Authorization Form. Odf CONTRACTOR INFORMATION Contractor Business Dutch Creek Electric Name Contractor's License 180075 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-620-6888 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email sarah@dutchcreekelectric.com Address Retype Contractor sarah@dutchcreekelectric.com Email Address DESCRIPTION OF WORK Is this an electrical Upgrade service upgrade or change? Number of Amps 150 Location of work house (garage, house, etc) Provide additional n/a details, if needed. Project Value (contract 3751 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Mike Taglialavore Pe rm it Email not displaying correctly? View it in your browser. City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202000457 PERMIT NO: 202000457 ISSUED: 02/28/2020 JOB ADDRESS: 3305 Harlan St EXPIRES: 02/27/2021 JOB DESCRIPTION: Replace 60K BTUs, 80% efficiency gas furnace in crawlspace *** CONTACTS *** OWNER (720)232-5714 WELLER MARY E SUB (303)993-9060 REED D BORTON 190315 PREMIER HEATING AND AIR *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,300.00 FEES Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 111.30 ** TOTAL ** 151e30 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202000457 PERMIT NO: 202000457 ISSUED: 02/28/2020 JOB ADDRESS: 3305 Harlan St EXPIRES: 02/27/2021 JOB DESCRIPTION: Replace 60K BTUs, 80% efficiency gas furnace in crawlspace I, by my signature, do he attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include al entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Budding Official and is not guaranteed. q, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Builc)fng Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Cj.ty of Wheat Ridge 0'-3/03/2020 1254 CHA PREMIER HEAUNG AND AIR CDA022426 AMOUNT BPSi LIC -CL9- TOTAL PEE PAID 1OO,OU CONTRACTOR HU! 190315 BHP 33O5 Harlon St 151.30 APPL/PEKMlT NU- 202000457 PAYMENT RECEIVED AMOUNT pP / 42111'� 251.30 AUH CUE: 72163735 TOTAL 251.30 Kimberly Cook 10 000 y � q From: no-reply@ci.wheatridge.co.us Sent: Thursday, February 27, 2020 1:55 PM To: CommDev Permits Subject: Online Form Submittal: Residential Furnace/Boiler Replacement Permit Application Residential Furnace/Boiler Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or BOILER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement residential furnace or boiler like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Attach Credit Card Authorization Form - **DO NOT ATTACHED RANDOM FORMS** 3305 harlan st Mary Weller 7202325714 Afbergie1974@gmail.com CC authorization wheatridge.pdf CONTRACTOR INFORMATION Contractor Business Premier Heating and Air Name Contractor's License 190315 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 3039939060 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address Permits@premieraircolorado.com Retype Contractor Email Permits@premieraircolorado.com Address DESCRIPTION OF WORK What type of unit is being Furnace installed? Number of BTUs 60 What is the efficiency 80 (%) of the unit? Is the unit GAS or Gas ELECTRIC? Where is the furnace or Crawl space boiler located (for example, basement, crawlspace, etc)? Project Value (contract 5300 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Berenise Ruiz Almanza Permit Email not displaying correctly? View it in your browser. City of Wheat Ridge E -Res. Window Replacement PERMIT - 201901349 PERMIT NO: 201901349 ISSUED: 06/28/2019 JOB ADDRESS: 3305 Harlan St EXPIRES: 06/27/2020 JOB DESCRIPTION: Replace 4 windows (garage, attic), u -value = .28 *** CONTACTS *** OWNER (303)238-9522 WELLER MARY E SUB (303)375-0745 PAUL BONOW 020146 CHAMPION WINDOWS OF DENVER *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,343.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 49.20 ** TOTAL ** 99.20 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. 1, by m signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thIs ermrt. I further attest that I am legally authorized to include all entities named within this document as partes to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpennit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services sion. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance orfWulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Ocial Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Kimberly Cook l l ` S�j From: no-reply@ci.wheatridge.co.us Sent: Friday, June 28, 2019 12:35 PM To: CommDev Permits Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Categories: Kim Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address **REQUIRED** Attach Credit Card Authorization Form - **DO NOT ATTACH RANDOM DOCUMENTS 3305 Harlan St Jennifer Bergman 402-350-3214 afbergie1974@gmail.com BergmanCC.pdf CONTRACTOR INFORMATION 1 Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Champion Window Co of Denver 020146 303-375-0745 Contractor Email Address shemans@getchampion.com Retype Contractor Email Address DESCRIPTION OF WORK Number of window and/or doors being replaced Location of window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the a -value of the window(s)/door(s)? City of Wheat Ridge requires the u -value to be .32 or better on windows.. Attach copy of window/door cut sheets showing sizes and a -value shemans@getchampion.com ALI Garage, Attic .28 Bergman.pdf Project Value (contract 2343.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work 2 under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Steve Hemans Permit Email not displaying correctly? View it in your browser. Pe /C,.+9 A.41' -61 /_!- 4V,PC, CHAMPION WINDOWS of DENVER lc V HOUSE DIAGRAM 10035 East 40th Ave #400 DENVER, CO. 80238 (303) 375-0745 Measure Date: Measured By:, Order Date: lVerified By: LABELr" ter• 4 � COLOR CODE LEGEND W While I T I Tan I ADB I Adobe I BR Brick Red I BRZ I Bronze EG Emerald Green CG I Cottage Gray CB I Colonial Blue EO English Oak Dark Oak CH Cherry ORDER CODE LEGEND: DH Double Hung DH -0 Double Hung Oriel 2P 2 -Panel 215-0 2 -Panel Oriel 3P 3 -Panel 3P -E 3 -Panel E ual Lite JHP Hopper PW -F Pix Wndow Frame Only AW Awni 1-Lite Csmtw/right Vent EcLCCLT, 1 -Lite Csmt w/ left Vent 2 -Lite Csmt 13LC 3 -Lite aseme 4LC 4Lile Caseme 3LC 5-1.1te Casemen GW Garden Window 2PE 2 Panel Egress SHE S i Hu Egress WINDOW SCREENS GLASS # LOC INSIDE MSRMT W X H OUTSIDE MSRMT W X H STYLE CLR ORDER SIZE W X H FULL YM GRIDS OBS TP COMMENTS STYLE1 LOC LOC LOC 04 2 Jt X Xl 1�1�7 i xJ I 3 5 x x x 6 x x x 7 x x X e x x x 9 x x x 101 x x x ZVZ 11 x x x ZZZ 12 x x x 13 x x x 14 x x x 15 x x x SHOP INSTRUCTIONS CHAMPION WINDOW MFG. 918200 91 700 Series '"mac Foam Enhanced Vinyl Frame Double Glaze • Low -15 M Argon Gas PAftommr C Casemennt W Window iillilfa i t ENERGY PERFORMANCE RATINGS U -Factor (U.SA.P.) Solar Heat Gain CAeffrckentt 0.28 0.19 ADDITIONAL PERFORMANCE RATINGS Visible Transmittance Condensation Resistance 0.46 60 ua.aert;rq,a,mnnm tExcaonc�nmree„e�oM� P *nmam eaacrmapswawr eabnesreceetMMramobdaa9dtan,nera,q�spreEratt.. wmeon Mol Med erry soma uN eon nawm.M aoaedigraay Oremaror em 6anaa.a ft","eavmo,tor.aerpomapertarwrw adernwka rMwNa.aro MMJ CHAMPION WINDOW MFG. 918200 91 8200 Series n Foam Enhanced Vinyl Frame Double Glaze • Low -E, -Argon Gas Rovouw CHWA-8-0003200000 Slider Window iiIlim� I Double Dung Window ENERGY PERFORMANCE RATINGS U-Faclor (U.SJI.P.) Solar Heat Gale Coefficient 0.28 0.21 ADDITIONAL PERFORMANCE RATINGS Visible Transmittance Condensation Resistartce 0.48 58 WeuAearx,czYm mu owe nmaweoaooaa ro ecawou htRt aooeam breaMmn came soma ��a�c�mas�nae'+emw'ayao�maero�rnai� �aSrmH, ler otlMrp[luaptavfnq.ad��ob MMil�L.y CHAMPION WINDOW MFG. 918200 91 Series a Foam Enhanced Vinyl Frame Double Glaze - Low -E • Argon Gas FbUCMW CHW-A 7.00050-00M iiIlim� I Double Dung Window ENERGY PERFORMANCE RATINGS U -Factor (U.SA.P.) Solar Heat Gain Coefficient 0.27 0.21 ADDITIONAL PERFORMANCE RATINGS Visib1e?ransmittarxe, Condensation Resistance 0.50 55 a>4nrs¢aimr.uugoo ma*oop�. f rmaool"brertixmmeosubM I oerbnr.Maw"0e8 psmeeeEemmbroa tlxMwmrrmY.. condi, an,,p.mTsQe, er,e eBN: son mt rtes aria eaJo.e'm�ne omega Momm tlrcmpaq of,eraemx�ax ery oo�arcosa Coeedl q' e3CsmmwprabraomapubmooaM*wa en, WON e,oq CHAMPION WINDOW MFG. 3100 Series a Vinyl Frame ze • Low -E - Argon Gas CHWA-1 Patio Door FbUCMW ENERGY PERFORMANCE RATINGS U -Factor (U.SJI.P.) Solar Heat (lain Coefficient 0.30 0-2 ADDITIONAL PERFORMANCE RATINGS Visibie Transmittance Condensation Resistance 0.51 56 . . � riV �Wft o � o3Mp� er,ocncxMora, and �mM,:rcc�2s1 wa�,s,m,� <c®cx rJa wwea,cot 60171mm1 *=neomaasMiNamee-�rasm'aoauxb<anrsv 4C¢CtrobmY &Utt.'�oa braft a�Pr+'-m4trlA ntm»m MOMCI[G'e 1* � 4 i CITY OF WHEAT RIDGE 1�9�Building Inspection Division (303) 234-5933 Inspection line '(303) 235-2855 Office ® (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:"'"', Job Address: Permit Number: C)CiI 0 V c ❑ No one available for inspection: Time R W )/PM Re -Inspection required: Yes o When corrections have been made, call for re -inspection at 303-234-5933 Date: t i ' Inspector: 1,F DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE C-( Building Inspection Division �(303) (303) 234-5933 Inspection line P35-2855 Office • (303) 237-8929-Ffax I/ INSPECTION NOTICE Inspection Type: C\ k n C_ Job Address:r'� J!� Permit Number: ni0 kV G 1� `��FICILL�r /� F'!' � i— I %� -•� s S S rte; !. (''➢ /�, Y �E,'`i a C ��� tiv l.. 1iZC C� ` lti r �\ f rl f/ X11 S S 4 r; t V I �? n ❑ No one available for inspection: Timer (_)U IVB/PM Re -Inspection requiredLY No When corrections have been made, call for re -inspection at 303-234-5933 Date: l I I I Inspector: I DO NOT REMOVE THIS NOTICE C-( . e /} F/ - 4b 4-k t_ �-'J 6 I/ 1.rn�C/ J!� L r 1iZC C� ` lti r �\ f rl f/ X11 S S 4 r; t V I �? n ❑ No one available for inspection: Timer (_)U IVB/PM Re -Inspection requiredLY No When corrections have been made, call for re -inspection at 303-234-5933 Date: l I I I Inspector: I DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 10s F Job Address: 336 a i.,eF/7 :5,7- Permit rPermit Number: o c ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes /No k When correcti ns have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building "Inspection Division (303) 234-5933 Inspection line _(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: \a Y\ Permit Number: d011 0 1 ;.A ❑ No one available for inspection: Time M Re -Inspection required: YesJd ; When corrections have been made, callforre-inspection at 303-234-5933 P Date: t Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 9 R laIqfh Job Address: 320T "r,114 S+, Permit Number: 201&)) 10 7 ❑ No one available for inspection: Time'tI A ) Re -Inspection required: 6e No When corrections have been made, call for re -inspection at 303-234-5933 Date: _111261 Inspector: /Y- Love 7t DO NOT REMOVE THIS NOTICE 00 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:�l1 l� Pl qh f� , Job Address: f.J o5 � _ (cI _ q Permit Number: 2616021 j q'� L ❑ No one available for inspection: Time ` 0 /PM Re -Inspection required: No When corrections have been made, call for re -inspection at 303 -234 - Date: I -! 1 i �4 Inspector: )CnP. TJz�F' DO NOT REMOVE THIS NOTICE i CITYbF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: D,--3 F'e _/ E �jc Job Address: Permit Number: Pr0f :� c2tj r2 -�--' ref Re -Inspection required: No When corrections have been made, call for re -inspection at 303-234-5933 r� Date: // /� � Inspector: `tom DO NOT REMOVE THIS NOTICE It. � 4 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ® (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: i ��_ �� f PIL4,111k, Job Address: 30� r[un S4 Permit Number: 2x16021 tri % % ❑ No one available for inspection: Time q!15— /PM Re -Inspection required: (�e) No When corrections have been made, call for re -inspection at 303-234-5933 Date: f / ��� 1 f Inspector:ba n� L���� DO NOT REMOVE THIS NOTICE 9 i CITY OF WHEAT RIDGE Buildtng InspectiorriDitrision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NO nCE 3 a 1- 800r') Inspection Type: 3 a o Job Address: 3 73 G S %n s' Permit Number: -a 0113 0 'O 1 <3 -7 ❑ No one available for inspection: Time f D = S) @M PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: ') r Inspector: moi] DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE A Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE f Inspection Type: -313- Q o L)A 2! ' Job Address: 33 0!5-- of r )a n G� Permit Number: "DO) g O 0) g 7 ❑ No one available for inspection: Time 9= d &M Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date:q r 1?q I Inspector: -7—b DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 1)E -/� o u � c' �cc De_ -.5- Job Address: Job 3 3 0 5-- SPermit PermitNumber: 0 1 B o 4 7 ❑ No one available for inspection: Timj AM/PM Re -Inspection required: Yes No When corrections have been made, call o e -inspection at 303-234-5933 Dae�!7-6_ (E)Inspector;DO NOT REM E THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -31 -3- o meq), )u�►►�,;, Job Address: -3 3 0 5— /— A r a„ S Permit Number: a 0 1 S o of 7 z`s `7 h ❑ No one available for inspection: Time /0:: 58 @PM Re -Inspection required: Q No When corrections have been made, call for re -inspection at 303-234-5933 Date:8 I I-P-7AqInspector: __1 _b DO NOT REMOVE THIS NOTICE City of Wheat Ridge Homeowner Interior Remodel PERMIT - 201802187 PERMIT NO: 201802187 ISSUED: 08/09/2018 JOB ADDRESS: 3305 Harlan St EXPIRES: 08/09/2019 JOB DESCRIPTION: Interior Remodel 175 square feet of Kitchen and Bath including electrical and plumbing. Add new 3/4 bath by converting existing closet space and re -pipe all water lines and drain waste and vent to code. Add electrical and necessary plumbing for washer/dryer and garbage disposal. *** CONTACTS *** OWNER (303)238-9522 MARY WELLER SUB (303)234-0460 Daniel McCord 020345 Colorado Concept Lighting *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 20,400.00 FEES Total Valuation 0.00 Plan Review Fee 246.12 Use Tax 428.40 Permit Fee 378.65 ** TOTAL ** 1,053.17 *** COMMENTS *** *** CONDITIONS *** I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. If professionals are hired, those contractors are licensed with the City of Wheat Ridge and are listed on the permit. Consultations and inspections will only be performed with the homeowner of record present.All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. L �f „E City of Wheat Ridge Homeowner Interior Remodel PERMIT - 201802187 PERMIT NO: 201802187 ISSUED: 08/09/2018 JOB ADDRESS: 3305 Harlan St EXPIRES: 08/09/2019 JOB DESCRIPTION: Interior Remodel 175 square feet of Kitchen and Bath including electrical and plumbing. Add new 3/4 bath by converting existing closet space and re -pipe all water lines and drain waste and vent to code. Add electrical and necessary plumbing for washer/dryer and garbage disposal. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of theproperty and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attes{ that I am legally authorized to include all entities named within this document as parties to the work to be perfor and,that all rk o be performed is disclosed in this document and/or its' accomp nyin approved plans and specifications. Signature of OWNED or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a pe it shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable cod�ny ordinanc7cc)r regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Buildinj Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of `7`Iheat P-.-_,dge comm UNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(d)-ci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: / / Plan/Permit # _20/00 v �S-7 Plan Review Fee: /%�% c / Z Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Prooertv Owner Property Owner Email: Tenant (Commercial Projects Only) I CX t ( I e �_ Property Owner Mailing Address: (if different than property address) -n e -,%I / I - / a _"N��� Address: 0 Phone� up l'T /0 City, State, Zip: C ,�, I c� e i, C O E0 q0 - 1?5�2 :;;z Architect/Engineer: 7XI f Cl- `\ le h CG Architect/Engineer E-mail: c � e v,(�� Sn , Phone: z�' Lw Contractor Name: Vg N IYI C Q 0 jr- City City of Wheat Ridge License #: Contractor E-mail Address<'& 10 l -c,- A o C'C> V, Phone: 30-3 /23 For Plan Review Questions & Comm/ents (please print): CONTACT NAME (please print): A Qa A? n d Y V e >/�e r Phone: 7Z � ,� -C, CONTACT EMAIL(p/ease print): �-p i� LK3 e_ I I C- M 5 /J ° Co l,-vl Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: Mechanical: W.R. City License 0 °`� W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # ❑ COMMERCIAL RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. 1 c—f1 Cc. v1 C... r 1 � vvr � � y1 I A CA CL 0-e w 13 I C Y e r I, Y� RC z 1 �i\r C l r= �^ r Cj C� ✓1 c( DvJ AcAcA C'_ Ie L -t rC I, 4f- r if C v^ CL r) Ct Sq. FULF �7 5 Amps v\cf C'/a•SJ ej eLcc; \LL ce�' .1 VA4tC eSs<< V, y r ILL �) : V\- (-1 �)ar be-IV't CA. r 5PcsA� 1, TU Gallons B s Squares Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Proje t Value: (Contract value or the cost of all materials and labor included in the entire project) b c2(), 4(11l>' OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT' I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): iJZ DATE: �t Printed Name: U ICC b �'l e- ` I V - DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: l� CONSTRUCTION TYPE: Reviewer: BUILDING DEPART Pti�ONtkFENT Revie PUBLIC WORKS COMMENTS: Reviewer: Building Division Valuation:24��,f Vev August 6, 2018 Wheat Ridge CO 80033 To whom it may concern, I am providing this letter at the request of Mary and Roland Weller. I understand this letter's purpose is to verify our relationship and indicate how long we have been friends. I have known Mary and Roland for some 25 years. We met during my time working for Jefferson County schools while Mary was employed in the food services department at Golden High School. Mary's mother and my mother also became friends. As for this work arrangement, I am a master plumber and I have offered to re -do the plumbing and add necessary hook-ups for a washer and dryer at her property on 3305 Harlan St. If there are any other questions my phone is 303 668-7983. Sincerely, Fred Beall -' City of Wh6atpsj�dge COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. This form will not be accepted with missing information. Project Address: 33 Q S 11 r Ia _5��ermit #% / l General Contractor: % Q „ d 1A) P ale f::� Electrical Sub -Contractor Company Namec.0 i E; 0 ,� c y hone #:.�c� 3 2 —® �, Q State License #: 5 Jyz Master #: 6LZ/ O Wheat Ridge License #: (J r t 7' 0 Plumbing Sub -Contractor (required field) Date Company Name: Fo eJ B ec+. /! Phone #: 3 03 Y2 State License #: 23 — l 30C G_ S S Master #: rq P C Cb 17 9 G L4 8 Wheat 'dge License #: (required field Z gnature of Authorized Agent Dat Mechanical Contractor Company Name: Wheat Ridge License #: Signature of Authorized Agent Phone: (required field) Date �. 4 0 F!E" City of n Wh6,atPsjd COMMUNITY DEVELOPMENTge Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owner(s): Project Property: Project Type: e / J T 1 A�� 1v -1n �u b Ne b �- /Ctct �h -3/ J c v S c S j z V' c S j C ►^ e� r y e r„'f �su LiD p w � h��u� �� v�C, � 1 I Notarized signature of Applicant � ► Y' � J�iC i j tr State of Colorado } County of J(fers, } ss The foregoing instrument was acknowledged by me this day of At,t 20Le by l -Jr'_ (i cr F ARA D ODEON TARY PUBLIC E OF COLORADO RY ID 20164015481 ON EXPIRES APRIL 22, 2020 �- 99ee My Commission Expires _�Zj 22 /2026) Notary Public 3305 Harlan St. Building Permit Information Wheat Ridge Colorado 80033 August 3, 2018 Rewire to code the kitchen and bathroom. Add wiring in existing kitchen for dishwasher, disposal, washer / dryer. Wire to code new addition of 3/ bath. New circuits will be Arc faulted and/or GFCI"ed per code. Will use existing electrical panel. Work to be done by Colorado Concept Lighting, Daniel McCord. Currently State Licensed and Licensed in City of Wheat Ridge. Re -pipe water lines and DWV to code. Add new piping for % bath. Work to be done by Fred Beall (friend) State License 83-1300585, Master License MP 00179048 Dry wall, tape and texture existing closet being converted to % bath. Electrical Value $6,400.00 Plumbing value $3,500.00 Carpenter -drywall $10,500.00 T7 114" - , 315 1 f2' 23' 11 1f2" 10'3 IW - -- Dining Room 252.76 sgft(23'11112'x10'6314") Living Room 11319 sq ft (12' 4 314" x 9' 1 3,14") p 10'S 112'-- - - --- . . II i 3' 5 112" --. 3' 2 1 BT' -1 •.__—_. 4'3' 2'53/4' 39* -- .t Master Bedroom 101.54 sq ft (11' 1 112" x 9'1 112") Kitchen 10214sgft(10'51/2"x10'7114') Bathroom TT 3270sgft 3'7114"x9'1'. Bathroom � % "1 59.535gft(6'7111444" -9'114-1 -lux t3.. 314' 5' 114' -_.__ -7 2'7"-'2' 5' 6 114- .. ... Hal: 1547sgft Bedroom 11176 sq ft(B'6"*13'1314') Closet 966sgft Bedroom 105.73 sq ft (9' 9 114' x 13' 2 314") closet 9.05 sq ft • -- 3'5 112' +++ _....._ T a tf2` J 4' t 112" *�- - '` 5 t12` _ "' 3' 7 114• „ ____..__�. 6' 7 114" . _.... .- "93/4. 3.5 112- +:. 4' 11 314' 12'4 113' - 11 1 tf2' - -- '- 13' 2 314' -_--- - .-� 1-1U\1TV DEVELOPMENT APPROVED v+ {or code compliance PlansE►a+ o Date MAWAY of 1".—it: To. Ond cc0,punp % f'r +vol UJ plpnS SpeCi�K0f1011$ ..,:. �� slgpM �- O + � � �:.•pruvul u. on OnY OJ OK p'� �.J Yvi0107ip0 Io presuming tc IOft" ' : of °���''tY ordmpnces. Permits 41tu-"nJca+.-e+fhe provisions If the Buildbg codes or Other ord—"Ce6O�'h�(+ty shcu +,ot t ootid v O Z O C, � � Y 2 S r N � W "} o �- O x 2 nd � d5 �o - x � a 00 _ 4,0 r 3 N C Z r. k a i K rx. i — A)6 - G( CO -6-5;C-7— 5hOW 20'4,0% 7-5 19 '4 211-7 NEC. • "Val wneilr Ridge etU+ianp uv;,;a, 33c5-114Qe � �1 u� N MtJt(KkjAk L -l-- i AV m Q' -ti k -T� Kf Vlodud �4 04P % -330 S 7- OQ/ Z L AN 5-Pioz,,o PI LLM Bar�cs- p 104-4ioo P — PERMIT: L �l��(4 ADDRESS: � 3 C' 5 441. v &n S+ JOB CODE: INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground ! Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground '71 fyr L i-- Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof '71 fyr L i-- 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 403 Final Electrical Residential 317 Rough Mechanical Commercial 404 Final Electrical Commercial 318 Boiler / Furnace 406 Final Mechanical Commercial 319 Hot water tank 407 Final Plumbing Residential 320 Drywall screw and Nail 408 Final Plumbing Commercial 321 Moisture board / shower walls 410 Final Window/Door 322 Rough Grading 411 Landscape/Park/Planning 323 Miscellaneous 412 Row/Drainage/Public Works 413 Flood plain Inspection Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection I sff =4 60r Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. �► A City of Wheat Ridge Residential Roofing PERMIT - 201704314 PERMIT N0: 201704314 ISSUED: 07/18/2017 JOB ADDRESS: 3305 Harlan ST EXPIRES: 07/18/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles with ROOF DECKING - 30 sq. (28 sq. pitched, 2 sq. flat) *** CONTACTS *** OWNER (720)232-5714 WELLER MARY SUB (303)862-9841 David Kole 160113 Colorado Western Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,053.75 FEES Total Valuation 0.00 PANU Use Tax 211.13 Permit Fee 220.15 r--- ** TOTAL ** 431.28 --------- - - *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. A r City of Wheat Ridge Residential Roofing PERMIT - 201704314 PERMIT NO: 201704314 ISSUED: 07/18/2017 JOB ADDRESS: 3305 Harlan ST EXPIRES: 07/18/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles with ROOF DECKING - 30 sq. (28 sq. pitched, 2 sq. flat) I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perfo xtf�l and That all y�prlp�t0 b� performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signatuof OWNE of CONTRACTC51i (Circle one) D to 1. This ermit was issued base -=on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. e Signature of Chie _i,_ ictal Date REQUESTS MUST BE MADE BY 11.59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett From: no-reply@ci.wheatri dge.co.us Sent: Monday, July 10, 2017 5:06 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Dane Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 3305 Harlan St. Wheat Ridge, CO 80033 Property Owner Name Mary Weller Property Owner Phone 720-232-5714 Number Property Owner Email Field not completed. Address 1 433 �� Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Colorado Western Construction 160113 303-862-9841 Contractor Email Address kolecwc@gmail.com Retype Contractor Email kolecwc@gmail.com Address DESCRIPTION OF WORK Are you re -decking the Yes roof? Description of Roofing Material Select Type of Material If "Other" is selected above, describe here: Asphalt/Composition Asphalt Field not completed. How many squares of the 28 material selected above? Does any portion of the Yes property include a flat roof? If yes, how many squares 2 on the flat roof? TOTAL SQUARES of all roofing material for this X project 2 Provide additional detail Removing and replacing 28 Sq of Asphalt/Composition here on the description of shingles to Atlas Storm master - hearthstone gray shingles. work. (Is this for a house The roof pitch is 8/12. or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) �6 d �� j, 74�— SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant David Kole/Colorado Western Construction Email not displaying correctly? View it in your browser. 3 COLORADO 8395 Sweetwater Road Lonetree, CO 80124 Telephone: (303) 862-9841 WESTERN CONSTRUCTION AGREEMENT Name: Z Date: i Address: .� .� r?"i��i�i?n 7 City/State: ,rpT� zip: Gb _ E Mail: �2�✓� �S �.d� Home Phone: / Work/Cell Phone:3,1;-- Sales ,- S�IIf Sales Rep: �Ji �%� 1� PInone:106� Storm Date: THE CONSUMER PROTECTION/ROOFING BILL DOES NOT ALLOW A ROOFING COMPANY TO WAIVE, PAY OR REBATE ANY INSURANCE DEDUCTIBLE Approximate/Scope of Services/ Materials & Costs Based on Current Known Damage Report —� Replace with: Shingle Manufacturer, Line 7R�� Coli y�-��/ Year anufacturer WarrantyZ� Labor Warranty:year (Guarantee against leaks) _ ta�rteerr_Hi�p and Ridge_ &R Pipe/Jackkss — R c Vents Type: _Turbine_T" urtle_Ridge_Other aInt roof stacks to match shingles _✓1c�e amend Water Shield—R&R Valley Metal �ft&R Step Flashing R&R Chimney Flashing _Lg /Md_Sm Y/R&R Rolled RoofingR&R Modified Bitumen D&R Satellite Dish, Qty=,Special Instructions w Roof Pitch 7/12-9/12_10/12-12/12_over12/12 Steep Charge_1 -2— sq, =Replace Decking (7/16 in. OSB) �— R&R Skylight, Qty=// _D&R Swamp Cooler TOTAL SQUARES —26, APPROXIMATE COST $ I 1%�. DAMAGE REPORT APPROXIMATE DATE OF SERVICE_—J_—J COLORADO WESTERN CONSTRUCTION LIMITED WARRANTY 5 YEARS REPLACEMENT OR REPAIR ON WORKMANSHIP GENERAL CONTRACTOR. Homeowner acknowledges COLORADO WESTERN CONSTRUCTION as a general contractor and as such shall be entitled to overhead and profit, as allowed by insurance industry standards. This only applies if the insurance company allows for overhead and profit. TERMS: By signing this Agreement, you, the homeowner, authorize COLORADO WESTERN CONSTRUCTION (the "Company") to act on your behalf and pursue your best interests with your insurance company in determining an appropriate roof and/or siding replacement or repair at a "price agreeable" to both the insurance company and Company with no additional costs to you except for your insurance deductible. When the "price agreeable" is determined It shall become the basis of the final contract price which consists of INSURANCE PROCEEDS INSURANCE DEDUCTIBLE (the "Final Contract Price") and you authorize Company to obtain labor and materials in accordance with the Final Contract Price and the specifications set out herein and on the reverse side hereof and to accomplish such replacement or repair. Accepted by (Homeowner): ( rint Fuli Name) Insurance Representative Agreement: It is understood that Colorado Western Construction will be contacting my insurance representative and or meeting on my property to determiinnee�scope of loss (property damage) and compensation for loss (amount to be repaired) Insurance Company//J��,t� ���✓l Claim# GSC/�� ` Property Owner Signatu COLORADO WESTERN CONSTRUCTION SWL HOLD IN TRUST ANY PAYMENT FROM THE PROPERTY OWNER UNTIL COLORADO WESTERN CONSTRUCTION HAS DELIVERED MATERIALS OR HAS PERFORMED A MAJORITY OF THE ROOFING WORK ON IHi, Rt�IUtN i IAL rnvrnnI I i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ur'7u y3i' % //J,orl 6Q)�- i (_0 I, l-1 i- � (C,.v/:2 /" 1 ❑ No one available for inspection: Time ` ` A /PM OWhen nspection required: esNo corrections have been e, call r re -inspection at 303-234-5933 i Date: /' /,l �? Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE // �(303) Building Inspection Division (303) 234-5933 Inspection line 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: f Permit Number: -7 v/ 0 C ,. /)/1_1 1 l LlNo one available for inspection: Time « L) tMlpM Re -Inspection required: Yes 61 When corrections have been made, call for re -inspection at 303-234-5933 Date: U l Inspector: DO NOT REMOVE THIS NOTICE A CITY OF WHEAT RIDGE �� Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: U T Permit Number: 2 c,/ 7b `4 4: ❑ No one available for inspection: Time AIVI/�4 Re -Inspection required: Yes jNo When corrections have been made, cal! & rre-iinspection at 303-234-5933 Date: -­7 � Inspector: rt DO NOT REMOVE THIS NOTICE INSPECTION RECORD OccupancV/TVpe T "VINSPECTION LINE: (303) 234-5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING To THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings/Caissons Sternwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French nmin Sewer Service Lines Water Service Lines POUR No CONCRETE UNTIL ABOVE HA CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) Do NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS Sheathing Lath / Wall tj Mid-Root Electrical Ser ice U I tric S BEEN — SIGNED Rough Plumbing Gas Piping 1�'Y' I Rough Mechanical ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING Framing t Insulation Sc Drywall Screw 9 "'NAL' Bectrical P um ng iCal lMeZa Roof I ding Final Fire Department R.O.W & Drainage Parking & Landscaping I LANNING & ZONING, FIRE AND PUBLICE WORKS AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. **NOTE: ALL ITEMS MUST 13E COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY ISISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF 0-C C-UPANCY NOR PERMISSION FOR OCCUPANCY. f i UCCUPANcy NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER i CITY OF WHEAT RIDGE Building Inspection Division r (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax ❑ No one available for inspection:, Time AM/PM Re- Inspection 7equiredi Yes No When corrections have been made, call for re inspection at 303 234 - 5933 Date: Inspector. O NOT REMOVE TH /S NOTICE INSPECTION NOTICE Inspection Type: k�07L Job Address: 33 2� c tom! -- Permit Number: /Ga 4'6_.3 ♦ 16 All i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE 1 Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: Y1110 Inspector: Jk~r'r_ r . DO NOT REMOVE THIS NOTICE A CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Eh~ ` Job Address: 3d5 a~ w- Permit Number: -1 b o 4CJ t ❑ No one available for inspection: Time ;-A P Re-Inspection required: Yes *When corrections hav11e been made, call for re pspection at 303-234-5933 Date: l U Inspector: to DO NOT REMOVE THIS N T/CE ISSUED:' 02/10/2010 :EXPIRES: 08/09/2010 rhriS 181.10 additiona 37.7 YJHEAT City of Wheat Ridge Building Division Date: ' m 7500 W. 29"i Ave., Wheat Ridge, CO 80033 / Office: 303-235-2855 * Fax: 303-237-8929 Plan oO<oaroo Inspection Line: 303-234-5933 Permit Building Permit Application Property Address: j -:~O ! ls~K I~I N Property Owner (please print): t t S S,ra i , ~ \ Mailing Address: (if different than property address) Address: Zip: Contractor: S~SZth~ z=;ti ~cZm2 s ( Lc_tGti s~ta~F'ttit~ 1x[~Z~dK5 Contractor License Phone -:-~a-o Phone: t 9 s'o~)- SG~23 Sub Contractors: Electrical City License Company: Plumbing City License Company Mechanical City License Company: Exp. Date: Use of space (description): Description of work: Exp. Date: Exp. Date: Construction Value: $ 4zP~C--VV (as calculated per the Building Valuation Data sheet) I Plan Review {due at time of submittal): $ Sq. Ft./L.Ft added: Squares / 6 BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit Plans sub'e d inspection. CIRLCE ONE.: ~(OOWNER CONTRACTOR) or PERSONAL REP ESE~TIVE of (OWNER) (CONTRATOR) PRINTNAME SIGNATURE:'/ Date COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 16623 Date: 1/6/2004 Property Owner: ELISSA BAITAGLlA Property Address: 3305 HARLAN ST Contractor License No. : 21813 Company: Commercial Fire & Water Inc. Phone: 233-2439 Phone: 420-1939 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT (OWNER)(CONTRACTOR) SIGNED DATE 1-7-0'1 Total: $18,280.42 $399.50 $259.68 $219.37 $878.55 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ri e . anees, for work under this permit. Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description : GARAGE: NEW TRUSSES, ROOF, GUTTERS & BRICK VENEER lli~~3J BUILDING DEPARTMENT USE ONLY ZoningCommentll: Approval : Zoning: }K"'" lil.uildl.,gComl'1iamll: Approval: OM PubliOlWork$~ITI'I'liI: Approval: SIC: Sq. Fl. : OK. 1/6/04 Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permil may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job The' ua CmOf a pe it or the appro val of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the pro sio 0 ' 9 codes or any other ordinance, law, rule or regulation. ;:r--<'I/h. Chie; BUildin~sp:ctor-- Please sign Terms and Conditions on reverse side of page, (1) (2) (3) APPLlCA TlON Building Permit Number: Date: Property Owner: Et:nsA j31\~ Property Address: ~- I{//RI./fIJ sr. WHG'If~, GO. ,~ Contractor License No.: till 1"3 Company Ca'f~ M?GtI~;e Phone: 3/~ .-Z;'I39 OWNER/CONTRACTOR StGNATURE OF UNDERSTANDING AND AGREEMENT Phone: -:r:/ 'IZo -/<:n9 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, ru~ or regulations of the City of Wheat RKJge or covenants, easements or restrictions of record; that aU measurements shown, and allegations made are accurate; that I have read and agree to abide by aU conditions printed 00 this application and that I assume lull responsibility for compliance with the Wheat Ridge Building Code (U.8.C) and all other applicable Wheat Ridge Ordinances, lorwof1<. under this permit (OWNER)(CONTRACTOR): SIGNED (OWNER)(CONTRACTOR): PRINTED DATE DATE Construction Value: $ /~/?SO "l. Permit Fee: $ Plan Review Fee: ~ Use Tax: $ Total Fee: $ DESCRIPTION: Gi'I'a4OC: )J6t.J ~6, Ro::;l", uUff(iX;. I i3t?ftt.. ~, p~ --- oS i' -~ iRllE C IE llw!E:[f) BUILDING DEPARTMENT USE ONLY sc Ute? 9 2a~H ZONING COMMENTS: ----t.:!f___ Approval: ---- Zoning: BUIlDING COMMENTS: Of<:- ?-- 0 V(Jfo~ Approval: Pusuc WORKS COMMENTS: Approval: " ' , , . r C -;-1 _ 1'" ~ JOCCUfJancy ElectJkill-lieenseNo: Company: "'ab Roof ,-,lorl!:S Plumbing License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: ,\e::"uentl<11 ,,-,,nIIS Mechanical License No: Company: (1) This ptrd Wllissued In accordInt.wtt:h the provision' sll: forth In your appIitatIon and il subjed: to the laws of lb. Stat. ofC0&0ra60 and to the Zoning Ragulations and BuHdmt Coda of Wheat Ridge, Coiorado or MY Il:ltW appice" ordInalltel of the Oty. (2) This penna thai ppire if (AI the wott aulboriztd il not commenced within sixty (60) days from .$11' d.. 0( (Bllb. buikling authorized it suspended 0( ~ for s pIllodO(l2G...... (3) If Ibi, ,..". ........ a n.. penN!: !'NY be ac:quir.d lor a ,.. of on.-h" the amount nonnally ~nd, provided no chan.. hn. been 0( wiI be mad. In the original pa.n, and ~'and..., suspension or abandonment has nol ucetlCMd OM (1) YMI. If chan.. have been or If suspension Of abandonment uCMCb 011.(1) )'U', fuI......... be patd lor I n.. pennIl (4) No work of any man.... thai! be don.1hIt wlI chantt the n.sural low of wat. c:auting a chin. probIern. (5) Conb'ador ... notify th. BuikIftg .,pltCtOr twInty-four (24) bourl In advance lor .. inspettions and thai receIv. written approval on inspection tard before proceeding wtlh SlKUtWv' ph.... of the job. (6) The I,suanu of. or the approval of drawings and spedfitationl shall not b. tontb'ued to be I penril for, nor an approval of, Iny viotltion of the provisions of th.buldlng or yodl.onInanoe,law,Nl.ornguldon. .1- MiTek* MlTek Industries, Inc. 7777 GlRliENBACK LANE SUITE 109 CITllUS HEIGHTS CA 95610 USA ~AX (916) 6761909 TELEPHONE (916) 6761'100 Re: 7836 HD1502/Commercial Fire,7836 The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision ba..~d on the parameters provide,d by Noble Truss-Colorado. Pages or sheets covered by this .seal: Rl 085291 7 thruR10852917 My license renewal date for tbe sts.te of Colorado is May 31, 2004. Yu, Ray The seal on these drawings indicate aoceptance of professional engineering responsibility solely for the truss componC1\ts shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSIITPI-1995 Sec. 2. ,t~. December 11,2003 lob l-fr'Ug9 . r'fiu8s 1ype-' 1838 I A 1 . .1 SCISSORS rIfobiBTnl$$COlorado Ir\O::SEjd.al;~; ColOrado ..__.n_ .. \: _ Fy-]~::::~mm~C~~Ar.~a36 .. -~ R10852917 '---;Ii: . SR1.....0. ctTf'f2002 ~IT8k lndustrle!l, Inc;. Wed Dee:; 10 11:32;49 2003 Page 1 4.2v' 3-1-1" 1'______ 3-1.14 R-1~.._.__~ 2011-6 ._""10_ .'_1-.,_...12-0-.9 n_n. f 2.11.B 2-1,-6 ~ .~1.!:! _ 2.~ 1-8 __-17-1~'.2. ___+-. 20-~" 2-1'-6 :i!oI1-6 I,----~~-'--l 3-1-,4 Seale !!II 1 :45.8 5><811 5 3><4 '" ---i' '-, 3x4 '" ~--:::----....... ., ---..........--..... B . ~~............~i~ -- . - -~:::--;~--..._ 3x4 -:.. .........-;: - -'- .~.::.:-~:...=' ._:-::::::.~- - ~::--...--.__ ~ 7:::: .' 3...........::~~::_ :::~.:::....... --<::::.::.~~:::-;;;.---~ 3Xe -:~. ~~ ":'_-'-..7.;'.-- 14 --...--=--.-.)t.....--. 3x6 .":,: ./":>' ___......~::._.... &10 .-.:::::___-. -"'~-:..............._ e 6><'2 ". ~:-./.::..~-~- ",>--/" 15 ~ _ -'-,.<-..::,:--~:~:::.- ex12." ~"~ _:.:';-;;;:>'- 15 3x4 .,-- ". 12 ..---..:-::::.:.~2.;--~- 9 c:;:;.-__..-,,/ axe " ""--<<..-- I'? ~ ...... <.-::_...--- axEl ~ 11 ----....... l;: ;;;:I~' 17 4.50 1'''' 4" '" ;;- 0 ,,~ 4.. _' - '-::I<;. *- .-- 10 ' 18 ~~ 3)f8 '.~' 6.00 1'f2 !. ,..~.t..:'!.L..__-t._..., a.1~.._-+-.~10..--+--..1~---I-_.' 3-1-14 2-11-6 2-11.6 2-11-6 lf~~t L'~;\Li.'[.'r;' BCOL 10.0 Code UBC971ANSI95 ---- --. -----.. LUMBER TO~ CHORD BOT CHORD WEBS ~ X 4 S~F 'B50F 1.5E 2 X 4 5PF 1660F 1-5E 2 X 3 SPF No.2 'gxcept. H6 2 X 8 OF-N ,95OF 1.7E 9.102 X B OF.N 1950F 1.7E 1.'72 X 4 SPF 1850F 1.SE 5-'42 X4 SPF 1650F 1.5E. 8-14 2 X 4WW SId 9." 2 X 4 SPF 1650F '.5E. 4-14 2 X 4 WW Std REACll0NS Ilb/sl2..l MsxHcII'Z Max Uplift '6= 117010-7-4.10=1'70/0.7.4 1e:-111Ilol;'ld ease 7) 1B=.401IIo,ad case 7), 10=.....W1(1oad caae 81 1,,:.'1~___~_F:~o-12._--+-~~1~_-l--'_'~ "--1 2011-6 201M z,.;M ~1.1. DEFL In (Ice) Vert(LLl 0.76 '4 Vert!TlI -1.18 14 Horz(TU 1.03 10 1 $t LC II Min lIdofl = 240 ';dofl"I'.' P;:'TES - > 362 MI120 >239 01. . _ " . .. Weight; 86 I~ GRIP 169/123 BRACING TOP CHORD Sheathed or 2-8-8 DC putlins, except gnd vertlclJl~- BOT CHORO RIgid c8Iling dil'*Ctlv ,pplled or 1$-8-12 oc: bracing. (1) TOTAL VERTlCAL Den. OF 1.181N. ~ . .rT. 14 AND IIORl%ONTAL DEFI.. OF 1.03 %N. EXPECTED I!' :IT. 10 (2) PROJECT ENGR. TO veRIfY 90TH DEIUCTl<JNS AS THEIl AIlE AbEClUATE TO THe STIl\JCTURAL SYSTl:M. (3) TeNIP. SHORl:NG AI'D CAM8ER SlJUEsTED (BY OTHEIlS) FORCES Ub). First Load Case Only TOP CHO~D '-'8=-"41.1-2=.3305, 2.3 --510~. :1-4=-5753. 4-5 ~.5575. 5.8--5575. 8-7=.6753. 7.8~.5102. 8.9=-3305. 9-10=-"41 BOT CHORD 17'18_0.18-17=3256.15-'6=5029. '4-15=867'.13-'4=6671. 12.13=5029. 11-12=3258,10.11-0 weBS 1_17=3060.2_17=_842.2_'6=1661. :1.16=-462. 3-'5=60'. 4-'5~.1e2. 5.14-4053. 5-14=_164,6-13=_162,7_13=601,1..12__482,8-12=1661. 8-11 =-S42, 9-11 ~30eO, 4-.14_-1e4 NOTES 11 This trutl:tl: h~ been ~$Ignl!d for thl! wind loads gen8f8t8d by 100 mph winds at 215 It.~ ground level. ul!llng 10.0 paf top chOrd dead load and 10.0 pst bot't(tm ohord dead lolld. in the gBbl8l1nd roof zone on an oceupenc:y oetegory I. eondition I enclo!led building, Yvith il!Ixpoaul'f: C ASCE 7-96 per UBCS7fANSIS6 tf end Wttieall Of eantilC\lers t;ldS't. tl'le'f are expo$ll!d tQ wind. If pcwches ex1S1, they ar'tl expoGBd to wind. The lumber DOllncreaS8 ill 1.33, and the plate grip inc:(ea&(1 is 1.33 2) Design lOlld Is be-Md (In 30.0 pst specifIed roof !lnow load. 31 Unbalanced MOw loada have ooen conait.tered for tnil desigrl. 4) OvsmElng has been design for 2.00 timn live load + :lead load. 5) This truss has been deaignad for a 10.0 psf bottom chord live loed nonconcurrent with ~y othel' live loada per Table ND. 1 G-B, UBC.97. :fs) ae3rinQ 3'1 jOint/51 18, 10 eontidera parallel to grain v,IUCl lJI1;mg ANSIITPt 1-1995 <:m;te to grain formula. BuhctinQ' de;ignel' ahould Vtlrifv capacity of bearing surfl!lce. ~ntin1Jed C1'}h:~1!I 2 .. WARNI G. Vulfy desI811 pOMlftl!tfrs and R~AD II/OTES ON THIS AND REVERSE SIDE BEFORE use OO!IIgn V\IlIItlIor UIe 6nly wllh Mttet connoC1Ml. Thill ttHfgn IS Hlllld Qnly lfI)On partIIl'IlOlOl"!;!JtIQwn anCIle lot atllflcllvklllfll building !!ai'TlponBnt to blllltlhtll,d arKlloadoli VArtl(l8l1y, Appl1C1DUlty at "ulgn ptlramotCll!l; *nd ~PIU InC(lrpClfttlofl of componGtlIls, rnllDltBllIlll1y Of building cf8lIllIner -l'Krt Irug.B dBBlgnllt, BrtI::lnA Bhown It lar IIlMrttl ItlJIport of IndlVidUIII :: mllmbtlm OI'ily, Mdf1Ionlllnfl'lporRf)' IJl'lcln~ ICIltl~ ~tablllt't dl.lrtn; conlltrVcfton II 11'10 mpon!llblllty 01" "" Illl'Octor ltIont' "rmal'lonl brRclng- 01 1M Ovonlll !ltnJCturfl fe: tho rll!lprlnl!llbl1lty ()r tho bl.llldlnljl d'efgner FOI' gt'InQl'Il1 gUidance. ~~oa~ltl~ h1brl\!Mlon, qualify lXIntf('ll, etoragl, dnllVlJry, erection. Ind bracIng, consult Q$T-M av'.1I1y standii'd, DSI- PI · Ie no tp-1t~Uon. I"d HI....' Iflndll", 11'I1II1.ltltt11Ml end BtKlhg ~COtflm8fidatlan Av~ll$ble ltol'l'l TnI_ It. In,,"ute, 513 D'Ona'l'll;! DrlWl, Mildl.on. WI lJ3'7U December 11,2003 I1Ir MiTek Industries, 1M. :: .::~.., \::::::-- iOlife T'rtiaiiCOlorsdolOO"" 'Sedai'ia; CoTofadO ---.. . .-.. I PI HD1502/CommerelafFil'C/7836 ~:V _ \ :_~'_... . (OptionoIlOlO'f1'3250 iOO3~.g;;T ._u_ 4.201" SFtf806t 17"2002 MlTek ~dustne6, Inc. Wed ec .' ~~~ trus& h~!l. been designed with ANS1/TPI 1-1995 critEf'i3. .OAD eASElS) Standard A WARNING. V-rlfy d"jg. p.ram.,-r, .1Ui READ .vons ON THIS AND REVIlRSF. SIDE DEFORE USE gtslgn valid lOr UJlA QI'lIy wlttl MlTek O~. "'1, cIIa1(1n fa Im_ Ql"tly Upon paramelorS: $hown, IInd I;: !or an IndIVIdUal building compononl to b" InlIttlHed and ~aclod """ICAlly, APPIIcaDIlIty of dllJllgn pcIl'.1mei'8re.and 11"*' IliC00000fllllDfl0f eompGn4lnl " relPOnliblllly DI bujldl'la Melgnor - tlOI trullll *Igner, BtaClng IIhDW11I' fgr I8tetllllUpporl of ImIlVlauB! w~b IMtI'Ibal'lJ only. Addltlona! klmFJDmry J:lraclnll to InllltO Mlblllty dUrI"'Il conatNdlon Illth, reaponllblllly of tIlA Al'lk!t1:Ir, AdlIltIomll permanom blll~no of lhe e\l1"!rnlllltnllltllrt II 1M teaponlllhlllty 01 1M lIulldlna dtl~lgn.r. PQr glneral GuldanOll rllQllt'dlng /J!lbflClllon, ql.ltllhy r.Qntrol, Elllll'IIgc, c:lAl",..ry, lllrecllon, end tlfltlllng. t:OnlIult on-II Dplllty 8TlIncf4lnll. DS8-i89 BrMlng .~lncatlOl'l,.net HID.1iI1 HtlfIdllt'lO ........llRtton .nd ."'lilng "~,"lMndIlttGII ftV"IIAOI" lrom TlWI PI'" Inltltute, 5Q O'Dllofria Drin, ...dl_n, WI 537,t Idr M1'Telc Industri8s, Inc. A'O~5.:~'~;J Labor Report 12/29/2003 Estimate: 102803-00002 Insured: ELISSA BATTAGLIA Property: 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 Home: 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 Home: (303) 233-2439 Claim Number: 06-K077-773 Policy Number: 06-94-0377-5 Type of Loss: COLLAPSE Deductible: $500.00 Price List: CODE5F3Dl RestorationlServicelRemodel with Service Charges Broken Out Date of Loss: 3/15/2003 Date Received: 10/3/2003 Date Inspected: 10/29/2003 Retail Labor Market Conditions Total Description Hours Quantity Units Per Unit Per Unit Amount Concrete anchor bolt - 5/8" x 12" 3.22 76.00 EA 1.97 0.00 149.72 Content Manipulation charge - per hour 8.00 8.00 HR 33.43 0.00 267.44 Remove Dumpster load - Approx. 30 yards, 5 tons of debris 0.00 2.00 EA 0.00 0.00 0.00 Breaker panel - 100 amp 4.86 1.00 EA 276.92 0.00 276.92 Meter mast for overhead power - 2" conduit 3.35 1.00 EA 190.72 0.00 190.72 Rewire - average residence - copper wiring 21.17 636.00 SF 1.90 0.00 1,208.40 Taxes, insurance, permits & fees (Bid item) 0.00 1.00 EA 0.00 0.00 0.00 Remove 2" x 10" lumber (1.67 BF per LF) 1.90 100.50 LF 0.61 0.00 61.31 2" x 10" lumber (1.67 BF per LF) 2.17 100.50 LF 1.23 0.00 123.62 Remove Stud wall- 2" x 4" - 16" oc 0.83 193.36 SF 0.14 0.00 27.07 Stud wall- 2" x 4" - 16" oc 3.25 193.36 SF 0.94 0.00 181. 76 Remove 4" x 4" square wood post (1.33 BF per LF) 0.68 16.00 LF 1.37 0.00 21.92 4" x 4" square wood post (1.33 BF per LF) 0.78 16.00 LF 2.74 0.00 43.84 102803-00002 Labor Report 12/29/2003 Retail Labor Market Conditions Total Description Hours Quantity Units Per Unit Per Unit Amount 'Misc. framing 24.00 24.00 HR 56.55 0.00 1,357.20 Support brick chimney during construction 0.00 1.00 EA 0.75 72.75 73.50 Temporary bracing for the roof per building department 0.00 1.00 EA 1.82 176.54 178.36 Remove Rafters - 2x4 - 24" OC (3-5/12 Gable, per SF of floor) 9.11 632.52 SF 0.46 0.00 290.96 Sheathing - plywood - 1/2" CDX 5.81 680.00 SF 0.48 0.00 326.40 Remove Sheathing - I" x 6" 2.36 193.36 SF 0.40 0.00 77.34 Sheathing - I" x 6" 2.75 193.36 SF 0.81 0.00 156.63 Remove Sheathing - I" x 6" 8.31 680.00 SF 0.40 0.00 2 72.00 Temporary shoring post - Screw jack (per day) 8.49 25.00 DA 19.21 0.00 480.25 Attic truss - 8/12 slope 21.06 508.00 LF 2.35 0.00 1,193.80 Remove Brick veneer 18.23 401.50 SF 1.46 0.00 586.19 Brick veneer 36.18 401.50 SF 4.18 0.00 1,678.28 'Remove Detach and reset-Ornamental iron - security grill - window - Standard grade 0.80 16.00 SF 1.61 0.00 25.76 Paint door/window trim & jamb - 2 coats (per side) 3.26 10.00 EA 14.15 0.00 141.50 Prime & paint exterior fascia - wood, 4"- 6" wide 0.98 52.17 LF 0.81 0.00 42.26 Exterior - seal or prime then paint with one finish coat 12.79 1,130.62 SF 0.49 0.00 554.01 3 tab - 20 yr. - compo shingle roofing - w/out felt 6.87 7.66 SQ 53.78 5.88 457.00 Remove Each add'llayer of compo shingles, remove and dispose of 4.10 13.60 SQ 9.71 0.04 132.60 Page: 2 102803-00002 Labor Report 12/29/2003 Retail Labor Market Conditions Total Description Hours Quantity Units Per Unit Per Unit Amount Remove Tear off, haul & dispose of 1st layer composition shingles 5.23 6.80 SQ 24.80 0.00 168.64 Remove Drip edge 0.68 104.17 LF 0.22 0.00 22.92 Drip edge 1.32 104.17 LF 0.76 0.00 79.16 Roofing felt - 15 lb. 1.37 6.80 SQ 12.10 0.94 88.67 Roof vent - turtle type 2.03 6.00 EA 20.29 0.00 121.74 Remove Siding - steel, (29 gauge) 1.51 193.36 SF 0.27 0.50 148.89 Siding - steel, (29 gauge) 3.72 193.36 SF 1.22 0.26 286.18 Remove Wrap wood window frame & trim with aluminum sheet 2.64 4.00 EA 21.30 0.00 85.20 Wrap wood window frame & trim with aluminum sheet 5.50 4.00 EA 85.42 0.00 341.68 Remove Fascia - 1" x 6" #1 pine 0.35 52.17 LF 0.22 0.00 11.48 Fascia - I" x 6" #1 pine 2.49 52.17 LF 2.96 0.00 154.42 Gutter / downspout - galvanized 1.89 37.00 LF 3.23 0.00 119.51 Wood window - double hWlg, 10- l5 sf 5.80 4.00 EA 91.82 0.00 367.28 Totals 12,572.53 Page: 3 102803-00002 Adjustments for Base Service Charges Carpenter - Mechanic Concrete Mason Demolition Laborer Electrician General Laborer Mason Brick/Stone Painter Roofer Siding Installer Non labor item Labor Report Total Adjustments for Base Service Charges 12/29/2003 Adjustment 126.70 139.08 0.00 113.94 33.43 92.48 86.74 0.00 124.28 0.00 716.65 Page: 4 Materials Report 12/29/2003 Estimate: 102803-00002 Insured: ELISSA BATTAGLIA Property: 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 Home: 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 Home: (303) 233-2439 Material Description Anchor bolt, 5/8" x 12" Electrical box - steel - single gang Electrical box - steel- double gang Electrical box - steel- 4" octagonal light Breaker panel - I 00 amp Circuit breaker - 110 volt - single pole Circuit breaker - 220 volt - double pole Hub connector for 2" rigid conduit Outlet box - includes 4 connectors and plaster ring Rigid conduit, 2" Romex staples - per 100 count box Nonmetallic sheathed cable, 1/0-3 RHW & I #4 bare grnd,alm 110 volt copper wiring (12/2 with ground) 220 volt copper wiring (8/3 with ground) 220 volt copper wiring (10/3 with ground) Weatherhead for 2" rigid conduit Wood shims I" x 6" #2 pine FirlLarch, 2x I 0 #2 & better FirlLarch, 2x4 #2 & better Fir timber - 4" x 4" Post caplbase, 4" (Simpson BC4 or =) Hurricane tie (Simpson HI or =) Sheathing - plywood, 1/2" CDX Attic truss - 8/12 slope Brick veneer Mortar mix - 80# bag Claim Nwnber: 06-K077-773 Policy Nwnber: 06-94-0377-5 Type of Loss: COLLAPSE Deductible: $500.00 Price List: CODE5F3D1 RestorationlServicelRemodel with Service Charges Broken Out Date of Loss: 3/15/2003 Date Received: 10/3/2003 Date Inspected: 10/29/2003 Quantity Unit Cost" Total 76.00 EA 0.56 42.560 15.26 EA 1.93 30.108 0.85 EA 2.84 2.463 3.39 EA 1.83 6.372 1.00 EA 55.50 55.503 12.05 EA 7.20 86.747 2.00 EA 15.90 31.800 1.00 EA 8.50 8.500 0.85 EA 6.85 5.938 10.53 LF 2.59 27.327 0.67 BX 1.66 1.140 15.23 LF 1.98 30.293 357.05 LF 0.19 71.159 13.39 LF 0.83 11.3 72 13.39 LF 0.36 5.008 1.00 EA 13.64 13.640 0.53 BN 5.60 2.949 429.69 LF 0.62 266.927 117.24 LF 1.16 135.674 569.38 LF 0.37 210.973 16.84 LF 1.71 28.830 4.00 EA 2.39 9.570 19.54 EA 0.46 8.993 23.61 SH 24.94 590.437 508.00 LF 4.42 2,246.611 3,019.02 EA 0.43 1,314.047 14.87 BG 7.38 109.838 Page: 5 102.803-00002 Materials Report 12/29/2003 16 gauge wall ties 28.78 EA 0.05 1.440 1 1/4" roofing barbs, (based on 50 Ib box) 16.42 LB 1.01 16.591 16d nails for nail gun - 2000 count box 0.34 BX 34.45 11.696 4d finish nails 0.55 LB 1.16 0.636 4d galvanized nails 8.00 LB 1.24 9.964 6d finish nails 0.53 LB 1.16 0.611 8d smooth box nails, (based on 50 lb box) 20.30 LB 0.67 13.673 16 gauge staples for air gun, approx 7200 count 0.08 BX 40.05 3.259 Caulking - Acrylic 4.00 TB 1.60 6.333 Latex paint 0.91 GL 22.82 20.885 Oil base paint 0.08 GL 29.99 2.304 Painter's putty 0.24 GL 15.33 3.568 160 - 180 grit sandpaper 10.39 SH 0.65 6.689 Exterior latex 3.72 GL 24.68 89.944 Exterior sealer 3.80 GL 22.66 84.315 Composition shingles - 20 year - 3 tab 7.66 SQ 28.32 216.933 Drip edge - painted aluminum, 10' lengths 11.57 EA 4.53 53.049 15 lb roofing felt 1.70 RL 16.90 28.743 Simplex roofing felt cap nails - (based on 50 lb box) 4.86 LB 1.02 4.985 Roof vent - turtle type 6.00 EA 12.95 77.700 Metal" J" trim used around openings 107.42 LF 0.29 32.105 Metal outside corner trim 7.16 LF 1.50 10.737 Siding - steel (29 gauge) 214.84 SF 1.27 272.943 Fascia - metal, 6" 59.26 LF 0.70 41.676 Fascia - wood, 1" x 6" 57.96 LF 1.07 61.964 Support brick chimney during construction 0.000 Temporary bracing for the roof per building department 0.000 Retail Materials Subtotal 6,427.49 Material Tax 6.700% @ 6,427.52 430.65 Total For Retail Materials 6,858.14 ** Rounded Cost Page: 6 Summary Report Estimate: 102803-00002 Insured: ELISSA BATTAGLIA Property: 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 Home: 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 Home: (303) 233-2439 Claim Nwnber: 06-K077-773 Policy Nwnber: 06-94-0377-5 Type of Loss: COLLAPSE Deductible: $500.00 PriceList: CODE5F3Dl Restoration/ServicelRemodel with Service Charges Broken Out Date of Loss: 3/15/2003 Date Received: 10/3/2003 Date Inspected: 10/29/2003 Summary for Contractors Payment Total Labor Amount Total Adjustments for Base Service Charges Supplies Allowance Equipment Allowance Overhead Profit 10.000% 10.000% @ 2],365.60 @ 2],365.60 ]2,572.53 7]6.65 2.57 1,215.55 2,136.56 2,136.56 Total Contractor Costs Deductible 18,780.42 (500.00) Net Contractor Payment 18,280.42 Page: 7 Estimate: Client: Property: Home: Claim Rep.: Estimator: Operator: Claim Unit: Agent Code: Claim Number 11/26/2003 102803-00002 ELISSA BATTAGLIA 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 3305 HARLAN ST WHEAT RIDGE, CO 80033-7419 Zewe, Dennis Zewe, Dennis DENNIS ESTIM Policy Number 06-94-0377-5 Type of Loss Collapse 06-K077-773 Dates: Date Contacted: 10/28/03 Date of Loss: Date Inspected: 03/15/03 10/29/03 Date Received: Date Entered: Price List: CODE5F3Dl RestorationlServicelRemodel with Service Charges Broken Out 10/03103 10/30/03 Home: (303) 233-2439 Business: (303) 420-1939 Business: (303) 420-1939 Deductible $ 500.00 ELISSA BATTAGLIA 102803-00002 Main Level Room: Roof! 678.31 Surface Area 104.18 Total Perimeter Length 0.00 Total Hip Length 339.08 Area of Face 2 6.78 Number of Squares 26.08 Total Ridge Length 339.23 Area of Face I 11/26/2003 Remove Tear off, haul & dispose of I st layer composition shingles Remove Each add'llayer of compo shingles, remove and dispose of Remove Each add'llayer of compo shingles, remove and dispose of Remove Sheathing - I" x 6" Remove Rafters - 2x4 - 24" OC (3-5/12 Gable, per SF of floor) Attic truss - 8/12 slope Concrete anchor bolt - 5/8" x 12" * Misc. framing Sheathing - plywood - 1/2" CDX R&R 2" x 10" lumber (1.67 BF per LF) R&R 4" x 4" square wood post (1.33 BF per LF) Roofing felt - 15 lb. 3 tab - 20 yr. - camp. shingle roofing - w/out felt R&R Drip edge Roof vent - turtle type Temporary bracing for the roof per building departtnent Support brick chimney during construction Rewire - average residence - copper wiring Breaker panel - 100 amp Meter mast for overhead power - 2lt conduit Content Manipulation charge - per hour 6.80 6.80 6.80 680 632.52 TR: 76 24 680 100.50 16 6.80 7.66 104.17 6 1 I 636 1 1 8 6.80 SQ 6.80 SQ 6.80 SQ 680.00 SF 632.52 SF 508.00 LF 76.00 EA 24.00 HR 680.00 SF 100.50 LF 16.00 LF 6.80 SQ 7.66 SQ 104.17 LF 6.00 EA 1.00EA 1.00EA 636.00 SF 1.00EA 1.00 EA 8.00 HR NOTES: 102803-00002 Page: 2 ELISSA BATTAGLIA 11/26/2003 Room: Exterior R&R Brick veneer This is to repair the damaged brick. R&R Fascia - 1 n x 6" #1 pine Detach & Reset Gutter / downspout - galvanized R&R Siding - steel, (29 gauge) R&R Wrap wood window frame & trim with aluminum sheet R&R Sheathing - 1" x 6" R&R Stud wall- 2" x 4" - 16" oc Detach & Reset Wood window - double hung, 10 - 15 sf * Remove Detach and reset-Ornamental iron - security grill - window - Standard grade Exterior - seal or prime then paint with one finish coat Prime & paint exterior fascia - wood, 4"- 6" wide Paint door/window trim & jamb - 2 coats (per side) Temporary shoring post - Screw jack (per day) This is to shore up the wall while replacing the brick wall. 401.50 401.50 SF 52,2 52.17 LF 37 37.00 LF 193.36 193.36 SF 4 4.00 EA 193.36 193.36 SF 193.36 19>:-36~;F 4 4.00 EA 16 16.00 SF 1130.62 1,130.62 SF 52.17 52.17 LF 10 10.00 EA 5*5 25.00 DA NOTES: Area Totals: Main Level 678.31 Surface Area 26.08 Total Ridge Length 339.08 Area of Face 2 6.78 Number of Squares 0.00 Total Hip Length 0.00 Area of Face 3 104.18 Total Perimeter Length 339.23 Area of Face 1 0.00 Area of Face 4 102803-00002 Page: 3 Iris Technologies, LLC ~~.~~ ~ Forensic Engineering ~ Fire Investigations a Facilities Planning a Energy Services November 12, 2003 Chris Senna State Farm Fire and Casualty Company P.O. Box 280929 Lakewood, Colorado 80228 Information for Iris Project No. F03239.00: Claim Number: lnsured: Date of Loss: Location: 06-K077-773 Elissa Batthelia March 19, 2003 3305 Harlan Street Wheat Ridge, Colorado 80033 Dear Mr. Senna: In response to your request, Iris Technologies, LLC investigated the site associated with the above-noted claim on October 20, 2003. The results of the investigation, which include site observations and conclusions, are presented herein. PROJECT BACKGROUND The insured's garage is a detached two-story, double wythe brick masonry structure with a conventionally framed gable roof. The structure was built in the late 1800s and was originally constructed as a barn. For the purposes of this report, the front of the garage is considered to face west. The severe snowstorm of March 2003 reportedly deposited approximately 4 feet of wet, heavy snow of the roof of the insured's garage. Several months after the snowstorm, a neighbor informed the insured that the garage roof was sagging. The insured then noted that the ridge of the garage roof was severely bowed and the faces of the roof structure exhibited significant deflection. The insured then discovered several twisted and broken members in the enclosed attic space above the garage, and gaps were noted between the edge of the garage roof and the exterior walls at the front and back of the structure. PERTINENT OBSERVATIONS AND PROJECT INFORMATION The following issues are based on observations made by the investigator during the site survey and information obtained through interviews with the insured: 911 Marfell Street Erie, Colorado 80516 Phone: (303) 665-2703 0 Fax: (303) 665-2705 Batthelia Residence November 12, 2003 Page 2 of 7 ~ ~ 1. The floor of the attic space over the garage is constructed with I-inch by 6-inch tongue and groove planking laid over 2-inch by 10-inch dimensional wood floor joists. There are two interior vertical posts that serve as supports for the ridge of the roof. One of these ridge supports has broken through the attic floor. The plank that broke had no means of structural support beneath the attic area. 1.1. The board dropped through the attic floor approximately 4 inches and now bears on a large structural beam that spans the lower garage ceiling. 1.2. The ridge board remained connected to the vertical support, resulting in the downward displacement of the ridge by approximately 4 inches at its connection point. 2. The vertical I-inch by 4-inch roof rafter supports are bowed and cracked. Only one toe- nailed fastener connects the ends of the inadequate supports to the roof rafters and attic floor boards. 2.1. Most of these vertical supports have caused the supporting attic floorboards to deflect downward. There is little additional support beneath the vertical roof supports, resulting in a downward deflection of the attic floorboards by approximately 1 inch without breaking. 3. Some of the ridge connections have separated from the ridge board. 3.1. Although the 2-inch by 4-inch rafters exhibit little deflection and no flexural cracks were found, many of the support members have separated from the lx4 ridge board. The nails have pulled away at the ridge connection causing the ends of some rafters to split. 4. The top plates of the exterior walls have deflected outward. 4.1. The 2xl0 top plates along the exterior bearing walls have deflected outward by as much as 5 inches. There is a noticeable gap between the top plate and the top of the exterior brick walls. 4.2. The top plates are attached to the top of each brick walls by only two bolts. Further, the top plates are spliced near the mid-span of the exterior walls, and the splices have separated. One bolt has pulled loose from the brick material on each side of the structure. 4.3. Structural calculations based on the design of the insured's garage indicated that once the vertical ridge support failed, the roof rafter assemblies could have deflected 5 inches horizontally. Since some of the top plate bolt connections failed, and the top plates separated at their splice connection, there was little horizontal restraint to hold Batthelia Residence ~overnber12,2003 Page 3 of 7 ~ the top plate in place. 5. There are several cracks in the exterior brick walls that appear old and are thought to be unrelated to the recent deflection of the roof structure. 5.1. There is a significant accumulation of dirt and debris within the cracks, indicating that these fractures occurred prior to the March 2003 event. Also, the location and pattern of the cracks are not consistent with lateral loads imposed by excessive roof loads. 5.2. The exterior walls of the garage are not bowing outward. There are, however, a few areas, particularly along the top of the east wall, that are leaning inward. These sections of the exterior brick walls appear to have been originally built with these observed irregularities. CONCLUSIONS AND RECOMMENDATIONS Based on the site investigation, it is the opinion of Iris Technologies, LLC that the damages observed to the garage roof occurred when the inadequately constructed roof system deflected and failed under the weight of the March 2003 snow load. The excessive weight of the snow caused the roof system's vertical support system to fail, which in turn overstressed and damaged the exterior wall top plates. The exterior brick structure, which exhibits signs of previous distress, were not damaged during the March 2003 event. Due to the extent of the observed damages, it is believed that repair of the existing roof system would be cost prohibitive. Hence, it is recommended that the roof system over the garage be removed and replaced with engineered trusses. An engineered truss system would be more cost effective, would relieve the horizontal pressures exerted on the walls by the existing roof configuration, and is easy to install. Further, attic trusses can be designed to maximize the usable space within the existing attic space. New exterior wall top plates will also have to be constructed and new bolt connections drilled and grouted into the existing masonry walls. The design and construction specifications for engineered trusses can be obtained through a representative of a qualified truss manufacturer; Iris Technologies, LLC can assist in identifying a qualified truss design professional and coordinating the required specification and installation efforts upon request. All comments made in this document are based on the conditions observed at the time of the site investigation. Inasmuch as the investigations and/ or site assessments of an existing structure/ facility requires that certain assumptions may not be verifiable without expending additional sums of money or destroying otherwise adequate or serviceable portions of the property, and that unknown or unknowable conditions may exist within the structure/facility, the homeowner/agent agrees by acceptance of this report, except for negligence on the part of Batthelia Residence ~overnber12,2003 Page 4 of 7 ~ Iris Technologies, LLC, to hold harmless, inderrmify and defend Iris Technologies, LLC from and against any and all claims arising out of the professional services provided by Iris Technologies, LLC. Sincerely, Iris Technologies, LLC Tim Morgen, P.E. Structural Division Manager tvk~~ \1 \l11~1 John D. Risi, P.E. Manager, Principal TM:JDR:mr Batthelia Residence November 12, 2003 Page 5 of 7 Figure 1: View of the west side of the garage exhibits the bow along the ridge of the roof. Figure 3: Due to the excessive snow loads in March 2003, one of two main ridge supports broke through the tongue & groove floorboard. ~ Figure 2: The second floor of the garage has a large attic space with a conventionally framed roof; the roof system is vertically support from the floor system. Figure 4: The ridge rafters have become separated from the ridge board. Batthelia Residence November 12, 2003 Page 6 of 7 Figure 5: The intermediate vertical rafter supports are bowed and cracked. Figure 7: The 2x4 rafters exhibit very little vertical deflection, and no flexural cracks were found. ~ Figure 6: Most of the intermediate vertical rafter supports have dropped down into the floor system. Figure 8: The 2x10 top plate along the west exterior wall has deflected outward by approximately 2 inches. Battbelia Residence November 12, 2003 Page 7 of 7 Figure 9: There are only two bolts along each 35-foot long masonry brick bearing wall that secure the top plate to the wall. Figure 11: The exterior brick walls exhibits cracking along several joints; this damage is not consistent with excessive roof loading and appears to pre-date the March 2003 event. ~ Figure 10: The top plate along the east exterior wall has deflected outward by approximately 5 inches due to the failure of the attachment bolt within the brick structure. Figure 12: The large gap between the exterior wall trim and brick structure indicates the severity of the horizontal roof deflection.