Loading...
HomeMy WebLinkAbout3835 Harlan StreetCITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office * (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Vj 0 V+ -1 Job Address: , R Permit Number: Q, k, � 0 (Z r "J iiJ P J No one available for inspection: Time AM/PM Re -inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-593 Date: Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE -.A Building Inspection Division (303) 234-5933 Inspection line '(303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: _3 Permit Number: c' J No one available for inspection: Time AM/PM Re -inspection required: Yes.1 No When corrections have been made, call for re -inspection at 303-234-5933 Date: ----,L Inspector: DO NOT REMOVE THIS NOTICE �s City of Wheat Ridge Commercial Sewer Repair PERMIT - 201901530 PERMIT NO: 201901530 ISSUED: 07/25/2019 JOB ADDRESS: 3835 Harlan St EXPIRES: 07/24/2020 JOB DESCRIPTION: Commercial 10 ft. spot repair on 1.5 domestic water service line on east side of property in parking lot. *** CONTACTS *** OWNER (303)422-1533 OLSON PAUL SUB (303)856-7476 JACOB WAKEHAM 140058 DIG BOSS LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 160 / Skilling Nursing BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,850.00 FEES Total Valuation 0.00 Use Tax 164.85 Permit Fee 172.60 ** TOTAL ** 337.45 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** City of Wheat Ridge Commercial Sewer Repair PERMIT - 201901530 PERMIT NO: 201901530 ISSUED: 07/25/2019 JOB ADDRESS: 3835 Harlan St EXPIRES: 07/24/2020 JOB DESCRIPTION: Commercial 10 ft. spot repair on 1.5 domestic water service line on east side of property in parking lot. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable bund ilding codes, and all applicable municipal codes, policies and procedures, athat I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this erin t I further attest that I a egally authorized to include all entities named within this document as parties to the work to be performed and that a ork to rformed is disclosed in this document and/or its' accompanying approved plans and specifications. "flL�/ "1 Signature of OWNER or CONTCTOR (Circle one) Date 1. This permit was issued based onTfie information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made -be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applesable code or aly, ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of CKief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of ,,�91 Wheat I-?.- dge COMMUNITY DEVELOPMENT Building & Inspection Services 7500 W. 29' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permits(a)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: ;/j Plan/Permit # c;o 186)1 s - Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: .?LS ALL J Property Owner (please print): puv1 061- Phone: Property Owner Email: (` Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer E-mail: Phone: Contractor Name: City of Wheat Ridge License #:©��ZC Phone: Contractor E-mail Address: &&anqA)dx&aam�%Y1P,r1 For Plan Review Questions & Comments (please print): CONTACT NAME (please print): �Jajfti Phone: 7aO- CONTACT EMAIL(p/ease print): Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: City License # Other City Licensed Sub: City License # Complete all highlighted fields, if applicable. COMMERCIAL ❑ RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Sq. Ft./LF P Jomellsc, wo'�c Sir 'fc& t`rv,- �Pv- - � BTUs Gallons Amps Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) OR'NER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (COT CTOR) or (AUT ORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last Dame):/ DATE: 7-Z-/9 -/9 Printed Name: �A (af. v DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer Building Division Valuation: � INSPECTIO R CORD O Occupanc,,'T�� , INSPECTION REQUEST LINE: Electrical (303) 234-5933 Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Inspections will not be performed unless this card is poste pr*e"ite. Call the inspection request line before 11:59 p.m. to receive an inspe 'on the following business day.** Inspector Must Sign ALL Spaces pe 'Hent tot 's project Fire Inspection / Fire Protection Dist. Foundation Inspections Date Inspector om nts Initials Lath / Wall Tie Pier Concrete Encased Ground (CEG) Rough Electric " Foundation / P.E. Letter Final Mechanical Do Not Pour Concrete Prior To Approval Of The Above InsbikiFarxi�' Underground/Slab Inspections Date Inspector Initials Comments Electrical Wall Sheathing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Sewer Service Mid -Roof Plumbing Fire Inspection / Fire Protection Dist. Do Not Cover Underground or Below/in-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Mid -Roof Fire Inspection / Fire Protection Dist. Lath / Wall Tie Final Plumbing Rough Electric " Final Mechanical Rough Plumbing/Gas Line Roof R119.1 ,191 .� Rough Mechanical Final Building Rough Framing NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof R119.1 ,191 .� Final Window/Doors Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. For notification of your assigned inspection time window please email insptimerequestAci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Time windows are assigned based on inspection routing. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M 1 1) Job Address: 3 i?3 S AA 5 Permit Number: - 2- 01 i020S4/ YU ❑ No one available for inspection: Time 12o d AM6 Re -Inspection required: Yes Vo When corrections have been made, call for re -inspection at 303-234- Date:- 6/" I/7 Inspector: GAe DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Roofing PERMIT - 201702054 PERMIT NO: 201702054 ISSUED: 06/16/2017 JOB ADDRESS: 3835 Harlan ST EXPIRES: 06/16/2018 JOB DESCRIPTION: Tear off existing material and reroof with Malarkey Legacy; 539 squares *** CONTACTS *** OWNER (303)838-4209 SANDALWOOD PARTNERSHIP SUB (303)425-7531 John Borfitz 019983 J & K Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 275,630.00 FEES Total Valuation 0.00 Use Tax 5,788.23 Permit Fee 2,267.25 ** TOTAL ** 8,055.48 *** COMMENTS *** *** CONDITIONS *** In order to pass a final inspection on commercial elastomeric or similar type roofing, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding K1/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€IMs installation instructions, whichever is more stringent. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Commercial Roofing PERMIT - 201702054 201702054 ISSUED: 06/16/2017 3835 Harlan ST EXPIRES: 06/16/2018 Tear off existing material and reroof with Malarkey Legacy; 539 squares I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermtt. I further attest that I am le ally authorized to include ali entities named within this document as partes to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRAC/IOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees andprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and sped is approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11.59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Cit} of WheatC� ComMUVITy DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 O 5t> Date: Plan # Perinit# ,ov 5 Building Permit Application c L..�/' Property Address:3b 35(M IQ.n •� V CUi �� l� (�Y �S� cvC "" Property Owner (please print): � � Frc L� Phone: Mailing Address: (if different than property address) Address: City, State, Zip: City License # City License # Description of work: - r�ro�-� �l Squares •` q BTU's Gallons Amps Sq Ft City License # Contract value: 275 Review Fee (due at time of submittal): 5 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that i am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal_owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWN ) (CON -CT y r (AflTH0jUZEDREPRESENTATIVE} mf (OY.'NER) (CONTRACTOR) PRINT NAME. � �o I �ZrkhousGIGNATURE: "U 1] ATE:—(4,-1 DEPARTMENT NT USE ONLY ZONING COMMENTS: Zoning: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: OCCUPANCY-, FIRE DEPARTMENT:: 0 approved w/ comments 0 disapproved 0 no review required i Bldg Valuation: CONTRACT J&K Roofing 13000 W. 43rd Drive • Golden, CO 80403 BBB Phone: 303-425-7531 • Fax: 303-425-1562 www.jkroofinl; com Representative Randy James Contact 720-935-2923 Date 6/15 2017 Name Sandalwood Manor (Jay Frazier) Phone 303-638-4209 Email JFrazier@colavria.com Address 3835 Harlan St. City Wheat Ridge State CO Zip 80033 Pinnacol Assurance 303-361-4000 Preferred Contractors Insurance Workers Compensation Insurance Policy #4079290 720-984-2471 General Liability Insurance Policy #PC72863-03 LABOR AND MATERIAL SPECIFICATIONS, TERMS, AND CONDITIONS. PLEASE READ CAREFULLY: ® Recover roof with Marlarkey Legacy ® Color of shingles Weatherwood ® Manufacturer's Warranty Limited Lifetime ® Tear off 1 layer ® Install Underlayment 30# ® Double all Eaves Starter ❑ Re -Flash Chimney and/or Skylights ® New Valleys Closed ®Replace Ridge All Impact Resistant Ventilation Replace all, Add eave vent to new section ® Galvanized Fasteners 6 Nails per ® Replace all Plumbing Jacks ® Paint roof stacks to match WW ® Install 2x4 eaves / 2x2 rake Metal Edging Antique Ivory ❑ Patio or Flat roof n/a ® 5 Year Warranty on labor ® J & K Roofing to furnish all material and labor ® Permit: Included but cost reinbursed by insurance ® Clean-up debris and haul off all trash from roof ® Roll yard with magnetic roller ® Gutters cleaned of roofing debris ® Decking Repair $2.00 per sf including labor ❑ Hidden Layers (tear off) $ per layer (Carrier) (Policy Number) (Claim #) (Adjustor) (Mortgage Co.)(Mortgage Loan Number) ❑ Extra work The property owner is M is not ❑ using proceeds from property and casualty insurance policy. Main Roof $272,467.33 Storage Unit 1 $1,965.61 Storage Unit 2 $1,197.92 Deductible if applicable $5000 Per Colorado State Law CRS 10-3-1115; 100 % the responsibility of the homeowner to pay this amount. A K Roofing will not reimburse or promise to reimburse in whole or in part any amount of the deductible. Estimated Start Date 6/19/17 TOTAL ESTIMATE $ 275,630.86 ALL PROPOSALS ARE SUBJECT TO MANAGEMENT APPROVAL J & K Representati e Randy JamesDate 6/15/17 �J Homeowner Date "Z4(' Expiration Date __U You have the right to recind this contract and obtain a full refund of any deposit within 72 hours after entering the contract. If you plan to use the Iroceeds from a property and casualty insurance policy to pay for the roofing work, you may rescind this contract within 72 hours after receiving ritten notice from your insurance carrier that your claim has been denied in whole or in part. However, J&K Roofing is entitled to retain payments or posits to compensate for roofing work actually performed in a workmanlike manner consistent with standard roofing practices. PLEASE SEE REVERSE SIDE FOR IMPORTANT INFORMATION All proposals subject to approval by management I/we agree to retain J & K Roofing, Inc. to replace and/or repair the roof with like material on the property listed on the front of the contract, contingent upon obtaining my insurance company's approval. I understand and agree that J & K Roofing, Inc. is to contact my insurance carrier and meet with their representative in order to discuss the repair or replacement work to be done. Upon agreement between my insurance carrier and J & K Roofing, Inc. as to the extent of the damages and not the cost to fix them, J & K Roofing, Inc. may begin to work on said property. understand that my OUT OF POCKET EXPENSE WILL NOT EXCEED MY HOMEOWNERS INSURANCE POLICY DEDUCTIBLE for work agreed upon between the insurance carrier and J & K Roofing, Inc. I also agree to provide all necessary documentation for the claim (including all pertinent documentation to facilitate the payment from insurance carrier/mortgage company). I agree and understand that J & K Roofing, Inc. reserves the right to file for a supplement claim to material or labor increases, in correct measurements, or for any standard cost that is relative and reasonable to the industry standard at the time. I agree that the equity in this property is security for this contract. This Contract shall become binding only upon written acceptance hereof by the Contractor or by the authorized agent of the contractor; or upon commencement of the work. This contract constitutes the entire understanding of the parties, and no other understandings, collateral or otherwise, shall be binding unless in writing and signed by both parties. I understand that after the three day right to rescind, there is a 15% cancellation fee. Labor warranty does not cover any damage to roofs caused by lightning, gale (50 MPH) hurricane, tornado, hailstorm, impact or foreign objects or other violent storm or casualty, or damage to roof do to settlement, distortion failure or cracking of the roof deck, walls, or foundations. The contractor shall revoke labor warranty if contract is not paid in full. The Material warranty is non -transferable unless otherwise stated by the manufacturer. All material is guaranteed to be as specified. All work is to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from the above specifications involving extra costs will be executed only upon written orders, and will become an extra charge over and above the estimate. Labor and material warranty covers roof only. I am to carry my own fire, tornado, and other necessary insurance J & K Roofing, Inc. is not responsible for mold or mildew the warranty is limited to roof leaks and replacement of missing shingles but does not include repair or reimbursement of water damage to the interior of the home. J & K Roofing, Inc. is not responsible for damage to concert concrete for driveways. J & K Roofing, Inc. is not responsible for making any aesthetic changes to the home or surrounding areas as result of the roof being completed. I understand that ice damming is an act of nature. I will not hold J & K Roofing, Inc. responsible for any leaks or damage caused by ice damming. Upon substantial completion of the roof final payment is due. A maximum credit card payment of $5,000 is allowed when using proceeds from property and casualty insurance policies. Final inspections for permit purposes cannot be used to withhold payment as some cities and counties become delinquent in their inspections due to large weather events or staffing issues. J&K Roofing hereby promises to provide resolution for any inspection issue. If final payment is not received within 30 days a finance charge of 3% per month not to exceed 12% per annum, will be charged to the account balance. I agree to pay all expenses of collection including reasonable attorney fees. A $50 charge will be imposed for each returned check. Homeowner initials J & K Roofing shall hold in trust any payment received from you until J & K Roofing has delivered roofing materials at the site or has performed a majority of the roofing work on your property. In the event that you choose to rescind your contract within 72 hours for any reason, any deposit will be refunded to the homeowner within 10 business days. By signing below I acknowledge that I have read the above agreement I understand all of the provisions that are outlined in the agreement, and I agre to the terms as they are written (s 20�� Homeo ignatur D to Homeowner Signature Date Z Representative Signature Date i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: A F Job Address: 332 til s�V' Permit Number:i�Q,Sy ❑ No one available for inspection: ime ' 05—A /PM Re -Inspection required: Yes ,^ When corrections have been made, call for re -inspection at 303 -234 - Date: TMI Inspector: ,��i A?4'� DO NOT REMOVE THIS NOTICE 0 Y - m MI W W N a Y - W O M m P. Y- a N z O n ro �' Y 0 n m o w rr H F,. F -j m n a. N m m Baa m w m n 0 Y- Y• m p �E rr n x m re H H m m m Ht- 0 ct ytl t�] rr olo Q 14 Y m tr 0 � Y- ro r �0 H W H O z �- K O 0 rr 0 n °z H O n IV b H p m tr a �1 r• 9 m ID R O m 7 n r v° ro 6 m r• m n � � w �T a rr r a m w a e a O M M n r• rT O m rr ro n � a r• Ir R a m a M O m �• a g c c � m r• w a r R a n aw m E n 0 p W 0 m p m c n n M c m � � n M• O ro a n CL o� n m m ro ISD O 0 w o m p m m m m m m a ro m 0 n Y M r' r r' IL m a w a n w o � a a m� o w 0� a W 0 n � ro a m o H r* r - m m m m n m n m a F+ p f* N a n rr r d• P, m 0 a a a m < m m ro (D rt N O dl O J 41 y t+7 O n HHC) y O d0 � O O � O W � W 00 i O O Tv1 N Pi y O d r7 (D aa4lueA,A 041 woad pae3 9141 }oaaoM penssl sl kouednoop jo a'e3iji}P8:3 V mun P8lIl J8d ION sl Aouedn3oo .,!ewe aul to cull loefgns ay; ul ssaippe Apadoid ay; glInn uolloadsui ayl jo step au; •W.d oo:g Aq sn,00•a pljleaynn•io ;sen ejawll su! llewa aseald — s;senbeH nnopulM ewll uol;oadsul jod.., •uolsln!Q buipl!n9 a4l Aq a6ellon M01 leola13919 pue 1014S!d aa!J aul woj) palaldwoo aje suolloadsul y6noa leul ains aq aseald — sllwjad a6e110n nnol a0=1,, -Aouedn000 jo uo►lezlaogjne alnjgsuoo lou scop uol;oadsul bulplln8 leul-4 a4l Jo lenoaaad nauuu",JaU fu aleol!peo a 9-jojaq,6ulpllng pue anj `sjfjoM oggnd `Butuueld Aq peAordd pue palaldwoo aq Isnw Mel! 11V :310N — _ — 6ulgwnld (030) punoj0 poseou3 819Jou00 l uep 931nuas vannas s;uawwo� sle1;!ul joloedsul a;ea suol;oadsul uol;epuno� sa0001nn0puwM 1e1J1=1 ssautsnq ftinnolloj au; uotlaadsut ue aAiaoai o; -tu-d 65: 11 aaolaq auil lsonbai not;oadsul aul lluD -alis loolold ail; uo pa;sod si pitlo situ ssolun pouuopod aq lou illm suolloadsul slel;lula;ed suoi;oadsul gelS/punoiBiepun look{ joloodsul - - - _ _. .. leolueyoaW leu!j inn -m lnwi nn 6ulgwnid leu!j leouloal3 leU1j •loafoid jnoA jo; louls!Q uoRoalad aJld a4l loeluoo suogoadsul all joi l ggZ-gEZ-£0£ 11BO suOpedsul a5euleip pue MOd jo j gt7gZ_gCZ-£o£ Ileo suolloadsul buhlied pue buldeospuel jod -aouenpe ul ilaann auo pa;sonbei eq pinoys salll;ua asayl woa} suolloadsul W VIS_ Z +- u- rt, r7 •1910 uo,loalad an j / uolloadsul aa!j -Ida(] s>uo/N 311Qnd / 96euleJO'8 MO I •1da0 6uluueld / 6u'Ved ig 6uldeospuel s;uawwo3 sleMulales ao;oadsul 'l suolloodsulleu!zi i' / t, lleN / m9JoS IIemAJO uollelnsul L� 6ulwej3 46nob leolueyoaW y6no�j ¢� ( aull se0/6ulgwnid y6no*d �/ L ou;oa13 y6no�j all Hem / 4181 10023 -Ml 6u!yleNs Hem s;uawwoo - - - - --•--- sle1;!ul jo;oadsul -.............,.�'•. 0390 a, suooadsul yBnoa l; nein^ innun IAAnl11AN1 OA -7YV�iJ Vaa.1M� vi•v\� V --l.L TV I—----�-- –i _. _ — _ — 6ulgwnld (030) punoj0 poseou3 819Jou00 l uep 931nuas vannas s;uawwo� sle1;!ul joloedsul a;ea suol;oadsul uol;epuno� 1931113913 ssautsnq ftinnolloj au; uotlaadsut ue aAiaoai o; -tu-d 65: 11 aaolaq auil lsonbai not;oadsul aul lluD -alis loolold ail; uo pa;sod si pitlo situ ssolun pouuopod aq lou illm suolloadsul slel;lula;ed suoi;oadsul gelS/punoiBiepun s;uawwoo joloodsul - - - _ _. .. ... ..... ....�..,.��,.. inn -m lnwi nn i-K-1Lu I( l/4Q `. -rte - J9119-1 •3•d / uo!lepuno=l (030) punoj0 poseou3 819Jou00 Bald s;uawwo� sle1;!ul joloedsul a;ea suol;oadsul uol;epuno� loafold 9141 of luoulped sooedS -1-1d u6iS IsnW .ioloedsul ssautsnq ftinnolloj au; uotlaadsut ue aAiaoai o; -tu-d 65: 11 aaolaq auil lsonbai not;oadsul aul lluD -alis loolold ail; uo pa;sod si pitlo situ ssolun pouuopod aq lou illm suolloadsul EE65-VEZ (EOE) :3NIl 1S3(lDMJ N®Il03dSNI '4L b(7 0 � • �� QH003M 1N0'.L3 N' �(7 v t/ p IS" /h t ! 1 j I '1 ril) �-Y-p `i/� a �� pus zta3p i-K-1Lu I( l/4Q `. -rte e CITY OF WHEAT RIDGE '' Building Inspection Division ' (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:! Job Address: 3 S— 7— Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: 1 i Inspector: f ,_ r DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: . S� � S 7— Permit Number:—r(�j/_ y v� _ 4b. ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Date: /el Inspector: 9 DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 3 5` Permit Number: C) ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: d/ Inspector: F DO NOT REMOVE THIS NOTICE = CITY OF WHEAT RIDGE i Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: .1� c,`.i S Job Address: 3'3 3 14 A x- / n pi Cv T Permit Number: --I. o a o 1-76(, 0 ❑ No one available for inspection: Time / Q : AM/PM Re -Inspection required: Yes No * When corrections have been made, calf for re -inspection at 303-234-5933 Date: "� Inspector: i DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE `/��� Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: P_T P_- S U( _ Job Address: -� K 3 Sfl a t i C" Permit Number: QQ) (,, O I—) G �> Fa s —7 e 4 -: - J::" Lg c -r . f .yam - fV ,c C( ri f PC , 4-1" ❑ No one available for inspection: Time � ; AV/PM Re -Inspection required: Yes No When corrections have been made, calf for re -inspection at 303-234-5933 --------__.---- Date: Inspectors,,_ I A DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Miscellan PERMIT - 201700121 PERMIT NO: 201700121 ISSUED: 01/26/2017 JOB ADDRESS: 3835 Harlan ST EXPIRES: 01/26/2018 JOB DESCRIPTION: Repair existing gazebo - Remove and replace walls on 3 sides of existing gazebo. New exterior siding, new wall dividing space for storage area. *** CONTACTS *** OWNER (303)421-3600 SANDALWOOD PARTNERSHIP GC (303)329-8003 Spectrum General Contractors 080173 Spectrum General Contractors *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned USE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,200.00 FEES Total Valuation 0.00 Plan Review Fee 32.70 Use Tax 21.60 Permit Fee 50.30 Investigative Fees 50.30 J� ` ** TOTAL ** 154.90 *** COMMENTS *** *** CONDITIONS *** **Permit fees doubled for work without permit.** MA: Approved per plans and red -line notes on plans. Must comply with 2012 IBC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of�0rk property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further st that I am legally authorized to include al i entities named within this document as parties to the work to be performed andhat alto be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWN01 or CONTRACTOR (Circle one) Date I. This permit was iMed based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 92 issuance aw 'all not be construed to be a permit for, or an approval of, an violation of any provision of any plicable codgulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official — Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of �`)`Iheatj�idge MUNITy DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(a)ci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: Plan/Permit # ! Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3935 S7r Property Owner (please print):�/'�✓11�� (.UDDD � t 1� 5�1' f P Phone: Property Owner Email: (-t- r-,R.z Lo c O I a - y r6 4 . xz Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor: Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form [� COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT OTHER (Describe) a6R A (A— (For A— (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 12 CV►� our ,, i C RLQ,5sv Gr�Z�5rf9tti1LIr` /UCw LVL /J(V(bIR.)�-- S & X02 5 TROY-71-� A -,-cry Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ 1Zl0ao OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) Electronic Si¢nature (first and last name): J ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: UTHORIZED REPRESENTATIVE) of (O DEPARTMENT USE ONLY (CONTRACTOR) DATE: t - Z & — oc-, / -7 OCCUPANCY CLASSIFICATION: Building Division Valuation: $ �c to 7 N a Vk d d � � T4 Ir l -w ON QD 9 Ki Qs t 3 it 9 aj L F� }l 9 P A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M 17 l r C P Job Address: 3835 N /+tzk r -'U 5 7 - Permit Permit Number: 2-o l L 0 t7 13 vu ❑ No one available for inspection: Time W. AM PM Re -Inspection required: Yes'lam *When corrections have been made, call for re -inspection at 303-234-5933 Date: ` - //_ 1 *� Inspector: DO NOT REMOVE THIS NOTICE Dec.29.2016 10:40 AM McBride Lighting, Inc. 3037788787 �:� 5-;L-3'7• K11;1 Vol City of 9COMAMUNITY Wheat�idge DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM Project Address: General Contractor: Permit #: 20 KP 0 D �� PAGE. 2/ 2 I Electrical Contractor oft c- , » Lt. G wT I cJ (m aw( E( e -c4 -rt cd qG5 I Company Name: Phone #:-3 v-3 , -7 7 S' 3 75`7 State License #;_ 2-� O (p Master #:�_ Signature of A rized Agent Date I Plumbing Contractor I Company Name: Phone #: State License #: Master #: Wheat Ridge License #: Signature of Authorized Agent Date Mechanical Contractor company Name: Phone: Wheat Ridge License #: Signature Au r4 d Agent Date *This application must be signed by each subcontractor confirming the same. City ) mE Building beep don tS' On 7500 W, 2e Ave,, Wheat Ridge, CO 80033 office, 303-235-2855 * Fax; 303,237-8929 Inspection i 303-234-5933 OAR 01;VtCE Ur.o Pon Review F",, Building Permit Appi cat'Orl 3835 Harlan Street, Wheat Midge Colorado 80033 . p 21- Sandalwood Partnership, LL � � � 30- 00 ,< Mailtog M (if dr Brent than propertY dre Mark Hoskiin Architects,m__ 303-365-0758 m t kir ha.h phone*----, � ontractors, Inc. c6nft*�'License � tub C-06"dow, WR City License WA, City, :u mns t,her Cfty Licensed Sub,, Othes City Licensedubf City I.icense City Lice Ma iat.. ` , (Check all that PP RESOENTtAL. rl ELECTRi e OCE UPS RADE _ , ° s s 1, Removal and of one d resident bathing to ilit 0 s.f. � 1 station as.f. rat o . Replacement of ceiling tits and light fixtures 1n halfway and lounge 3. New casework with sink in lounge - 1 I IJ 4. New casework with sink in fining - 28 1J. Gallonsw. Muls s tJLF squaresAMPS W� ... w r v � (Contract value r baa s gat � t l � � ��� �� 0 � � pioo�i .,. 1 as saa€g , aaa,. aaa apt°AN do saaaa �r'aalaaa aa�°s�aYba:��, �aat�aaaasaa:ati aha ons d y% SIGNAI by a 3r of mcard; that as aaaa:aaa€ aaaaasay aaxra ra o a s as a as as aurae I aam alae y'13,baa a the Setback dn"MCC-5 CT ataaa to caara.aasasaxta cava ti tflaa s ataaa aaaaaazibilitaat sa�a.aWr .a tiara r to ataaara ca dtaa �� � aat to Ridge � a as�� ai ants C Ma txaa,assats Se"�a"tethatt Via° aa� aaaa as Fav a esti as as a aaaa € c aaht,,,j agar . and an) 4110 ties �taca"''z' tai, �taC awl WitIaSa3& "t aaWSaaa a and ara€aa karp �a��sa aasar say c�aa aa*, saarz� a by the aaaa sof"the Vi included to :a a a aaaar� aa> � a that aatkY titin 1aaaapplication"� � ) (( `4Crt ) a " = fl RA ' R) WON -,em ar- Building DivisiOfl Cih- of W, I TN OF "f0%fir RIXif-BL, IRIAN",, ANID JNSP1,' HON SkR\101S DWISR)N ",,""("), , 0013,8(01' 301,2,35IA55, 30",""7JO-29 � , 4 th A ve Wheat Riqe, ( - I -, � Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit SubrrritW Checklist for the pr jet type and be attached to the Building Permit Application at the tine of submission, Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed, Date: 3835 Harladd" " 0033 et Wheat Ridge, Colora Project Address: Name of Firm/individual submitting documents: Project Type/Description: Interior tenant finish at skilled Signature of Firm "/1 JV V -r am a duly authorized representative of the agency indicated below and do, by my,,, signaturbelow, hereby acknowled qe receipt of docunlents necessary for, review and approval of, the, project indicated above, (Flease ch(�ck one) West Metro Fire Protection Arvada Fire Protection Wheat Ridge Water District Consolidated Mutual Water District o, c Valley Water- District c, Denver Water Wheat Ridge Sanitation District Clear Creek Sanitation District Froitclale Sanitation District c) Westridge Sanitation District c-,� Other, .,Ity 01' ,.084 GROUP HOME/ ASSISTED LIVING/NURSING HOME/ELDERLY CARE QUESTIONNAIRE origjnal of this form must accompany Ajl,_L applications for permit for the above oecupancy types) "its fonn is required to be signedby an owner/managing employee of"the that will be responsiblefor administration thefacility and pare, of the occupwits" both, if they are ditTering indivi tines) . Will my f the.rets reside within the facility on a 24-hour basis? Yes . �-w No a Are any of the occupants u r 2-1/2 e k ,� No x .. If Yes, hwar 3. Are. yg of the t that h ,h al limitations, am tal limitations, cheinical dependency, or medical treatment, camot responds an, individual (need assistance/are,incapable of s _i nr ttun) in ars emergency situation? Yes X No If yes, hum° many under 2-1/years of age's _ 0-- ,.m— f f" yes, how many over 2-1/2 of age? Printed Title Signature este Printed Name Title, Signature Date Rid City of Wheat Ridge F, Commercial Mechanica PERMIT - 201601213 PERMIT NO: 201601213 ISSUED: 09/12/2016 JOB ADDRESS: 3835 Harlan ST EXPIRES: 09/12/2017 6TOB DESCRIPTION: Install new heating only make-up air unit and ductwork., New electrical. *** CONTACTS *** OWNER (303)638-4209 SANDALWOOD PARTNERSHIP SUB (303)455-2825 Corp. 017128 Tolin Mechanical Systems Co. * * * PARCEL INFO * * * ZONE CODE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned USE: / BLOCK/LOT#: 0 / ** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 49,794.00 Wm.** COMMENTS *** *** CONDITIONS *** I, by my si *nature, do hereby attest that the work to be performed shall comply with all accotnpanying approved plans and specifications, applicable wilding codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be mimed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issua �orgranti g of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any applicabl o mance regulation of this jurisdiction. Approval of work is subject to field inspection. /wA/ Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. FEES Total Valuation Plan Review Fee 0.00 474.21 Use Tax 896.29 Permit Fee 729.55 ** TOTAL ** 2,100.05 Wm.** COMMENTS *** *** CONDITIONS *** I, by my si *nature, do hereby attest that the work to be performed shall comply with all accotnpanying approved plans and specifications, applicable wilding codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be mimed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issua �orgranti g of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any applicabl o mance regulation of this jurisdiction. Approval of work is subject to field inspection. /wA/ Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ni z1 3 INSPEC'T'ION RECORD iNSPECTiON RE—QUEST LINE: (303) 234-5933 Occupancy,Ty�e Inspections will not be performed unless this card is posted on the project site. 1 the inspection request line before 11:59 p.m. to receive an inspection the following business day. Inspector Must Sign ALL Spaces pertinent to this project lation Inspections Date Inspector Initials Comments hic Slab Reinforcement Electric iervice (Underground) is ig (Below / In -slab) to Encased Ground (CEG) iing (Below / In -slab) /Stemwall P.E. Letter Do Not Pour Concrete Prior To Approyal Of The Above Inspections ground/Slab Inspections Date Inspector Comments Initials al (Underground) ieathing Date Service (Underground) Comments Electric iervice (Underground) plumbing ig (Below / In -slab) iing (Below / In -slab) Final Mechanical lot Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections i Inspections Date Inspector Comments Initials eathing ieathing Date fall Tie Comments Electric plumbing Mechanical iing Do Not Proceed Without Approval Of Above Rough Inspections Rough Framing w Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Final Electrical Final Plumbing Final Mechanical Roof c I( ( m, Final Building / Frame Landscaping & Parking / Planning Dept. Inspections from these entities should be requests one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. "Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. 6 Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: O Job Address: 3 Permit Number: 0 41::� r< 112�A rfQOIFr)L—> ❑ No one available for inspection: Time /%; 3tj" AIV/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date:jj,Q f7/(, Inspector DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Mechanica PERMIT - 201601213 PERMIT NO: 201601213 ISSUED: 09/12/2016 JOB ADDRESS: 3835 Harlan ST EXPIRES: 09/12/2017 JOB DESCRIPTION: Install new heating only make-up air unit and ductwork., New electrical. *** CONTACTS *** OWNER (303)638-4209 SANDALWOOD PARTNERSHIP SUB (303)455-2825 Corp. 017128 Tolin Mechanical Systems Co. *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned USE: / BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 49,794.00 FEES Total Valuation 0.00 IPA I mrvk Plan Review Fee 474.21 Use Tax 896.29 Permit Fee 729.55 ** TOTAL ** 2,100.05 *** COMMENTS *** *** CONDITIONS *** I, by my signature, do hereby attest that the work to be performed shall comply with all accompany ingg approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am tl�e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I urther attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed that all work to be pe o ed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or C&qfRYTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit ho der shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or ranting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable c e r any ordi ce or r gulation of this jurisdiction. Approval of work is subject to field inspection. ' Signature of Chief Building Official Datr -- I REQUESTS MUST BE MADE BY 11:59PH ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heatj,jge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 Email' nermitsOci wheatridoe.co.us #15 FOR OFFICE USE ONLY X1 Date: 08 i j l Plan/Permit # Plan Review Fee: PAID Building Permit Application , "* Please complete all highlighted areas on both sides of this form. Incomplete applications may no ceased. ?d t I a oID Property Address: J J �S n �� I414 1 6� 1✓ i �' 17d -.p U Property Owner (please print)' Sv, y� �,4 �, I �✓oc� J /1161 V o r, Property Owner Email: Mailing Address: (if different than property address) Arirlracc- City, State, Zip: Architect/En i neer: /M ' °►ZZP I Architect/Engineer E-mail: G (y Phone: Y Contractor � L�' l �P c S✓I r c I S,�J�Cv�►s Contractors City License M �� b Phone: Contractor E-mail Address: k lec—, f ; (ZI k) ✓t CVL, Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) j n St-.�w h e �t O A y 114 e of e-; N� 2c) Sq. Ft/LF Btu's l I Gallons Amps Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information prov' d on the application. CIRCLE ONE: (OWNER) (CONTRACTOR or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) -?/L2 0 Electronic Signature (first and last name): DATE: 16-I L DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: e,' q/, y�/L r Building Division Valuation: $ « C m ,« «2 < y 27706 :2 ?« , co 8+22 paCta 303-948-5429 FAX 303-972-7453 IS Janet K. Sullivan Written evidence of conrliance with local zoning codes must be obtalnedprior to afinal on-site Life So/eV Code inspection. Contact the chy or county department in your area and have the director or designee sign below. The original signed form must be returned to the attention o ft i Safety Code Plan Review Intake at the address listed above. IM PURPOSE OF APPLICATION: Initial Licensed Facility (,Check gt That apply) f Change in Secured Beds Change of Ownership .o� Change in Licensed Beds MHLMM��� From: To: (0 ray - — an - ip — tion for AL or _Mfacifities) From: TO: Oro From: To: Scope of Project: M Zoning Department having Jurisdiction: Address:–_ 3, 9 ♦m o "'x`M1a'ii g IV i z a � c* , n m p D.� 0 t! r m Ta 9 0 Z y > ?4 y z y M m .`., t= m n o v T Z El t T m xz a - m D_y. m L N �i dam I , m "o M ,! m nz� . m a >o m f m M a i\ m M o x �a oa z, y t '^� J i m r' IA �yclS H W' E - 1 El m o 9 n D . z 3 > D 1 ' 0 z v O m z o mm `.n n a y o � f mks � ❑ A A \ y HP z : rr l Ao p nonA I � (D Z n�O -O an � p NI n n o �> City of Wheatpge - COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29 °i Ave. Wheat Ridge, CO 80033 -8001 P: 303.235.2846 F: 303.235.2857 DATE: March 22, 2011 TO: Accounting Department FROM: Meredith Reckert, Senior Planner SUBJECT: ESCROW REFUND /RELEASE Reimbursement requested for funds in the amount of $1597.50 (one thousand five hundred ninety -seven dollars and fifty cents) being held for landscaping improvements: Sandalwood Manor 3835 Harlan Street The Landscape improvement has been completed to the City of Wheat Ridge's satisfaction. MAKE PAYMENT TO: Sandalwood Manor SEND TO: 3835 Harlan Street Wheat Ridge, CO 80033 Attn: Angela Byrne � 3 /2z /ir M eredith Reckert for Ken Johnstone Director of Community Development www.ci.wheatridge.co.us CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: l Job Address/Permit Number: 3 ` ~4rr r r' ~J f p t ❑ No one available for inspection: Time AM/PM is F' Re-Inspection required: "Yes No When corrections have been made, call for re-inspection at 303-234-5933 i j Date: /,S i b z u Inspector: /1r_a 4: ' r D~NOT REMOVE THIS NOTICE i ~ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: -Sa Job Address/Permit Number: 5 rltzi ❑ No one available for inspection: Time AM/PM Re-Inspection required: "Yes No When corrections have been made, call for re-inspection at 303-234-5933 _ Date: /~C~-sue? u ~y ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: 1A - ,z Al Job Address: 3f'3S .s¢ �a�l t.✓ Permit Number: o 039th .Ri °Pk'�vf� ❑ No one available for inspection: Time >t,'VD AM /PM Re- Inspection required: Yes "When corrections have been made, call for re-inspection of 303- 234 -5933 Date: Inspector DO NOT REMOVE THIS NOTICE City of JO +a. Address'. City, State, Zip: E - aG Q k/( ' -DesipApUon.of ar GallonsI Ain NUOVIII 1�' 0#11 �f C. 011 O(IL� i�� _Am, , f OWNER/CONTRACTOR, 41 + IRC ON -6 (OWNER) (CONT T0,,R) jr-(AI/TNO&ZED REPRESENTATIVE) of (owNm (Coo p � DEPARTMENT USE ONLY ZON4NG COMMENTS: zon frig: Remievver, Reviewer: PUBLIC R COMMENTS: OCCUPANCY:— Reviewer U Y:R r: FIRE DEPARTMENT:: 0 approved rrnnwnts 0 disaWoved 0 no review required• +:. a .: !A 1 City of Wheat' Ridge Commercial Sign` PERMIT 093538 PERMIT NO: 093538 ISSUED:... 10/21/2009 JOB ADDRESS:. 3835. HARLAN ST EXPIRES:. .04/19/2010 DESCRIPTION: Free standing sign 50 sqs ft CONTACTS owner 303/422-1533 Richard Whelan gc 303/329-8003 08-0173 Spectrum General Contractors PARCEL INFO ZONE CODE: C-1 USE: C-1 SUBDIVISION: UA BLOCK/LOT#: 0/ FEE. SUMMARY** ESTIMATED PROJECT VALUATION: 2,200.00 FEES Permit Fee 108.30 Plane Review Fee - 70.40 s Total Valuation .00 Use Tax 39.60 TOTAL 218.30 Conditions: AT: Sign permitted in sight triangle as per AASHTO..Sight triangle regulations. for signalized intersections. C-T' JS: Approved. Lettering change to existing sign only. Subject to field inspection. I hereby certify that the setback distances proposed by this permit application are accurate, and, do not violate applicable. ordinances, rules or. regulations of the City of Wheat Ridge or covenants, easements. or. restrictions of record; that all measuremen?)h shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this.. applicati ad that I assume full response aty for compliance with the Wheat Ridge Building Code (I.B. C) and all other applicab Wheat Ridge Orden. nces, for w k rider this perm' P1 ns subject to field inspection. Signature of contractor/owner da e 1. This permit. was issued in accordance. with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3.. If this permit expires, a new permit may. be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made.. in the original. plans and specifications and any suspension or abandonment has not - exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing adrainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, a violation of the provisions of the building codes or any other ordinance, law, rule or regulation..' All plan rev' ubject to field inspections. Signature o i V Building Official date INSPECTfON REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. (,,04 DO City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Property Address: Property Owner (please print): ✓7 l 33 Mailing Address: (if different than property address) Address: Citv, State, Zip: Contractor: ~.~PC L! ~ivv` l~ e Py tx C C9rt 1 Yacne^ S Contractor License Phone• 363- 3Z9 900 Sub Contractors; Electrical City License Plumbing City L Company: Company icense Mechanical City License Company: Exp. Date: Exp. Date: Approval: Approval: Exp. Date: Approval: Use of space (description): Description oT;work Construction Value: ~t (as calculated per the Building Valuation Data sheet) Plan Review (due at time. ofsubmittal): $ , Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTRTIVE of (O ER) (CO RATOR) PRINT NAME: VT4 Lie r5 P SIGNATURE: 666666Y=YFMd ( i Date: Date: Plan C /-t'i3C)7~- Permit Bldg Valuation: $ Building Permit Application City of Wheat COMMUNITY DEVELOPMENT Building Inspection Division Plan Review Notes 10/09/09 Spectrum General Contractors 5135 E. 38`h Avenue Denver, CO 80207 Project Address: 3835 Harlan Street A review of your submittal documents for City of Wheat Ridge Plan #09-0307 for a monument sign at 3835 Harlan Street, Wheat Ridge, CO, 80033 was conducted and the following corrections to the submitted plans are required: 1. Footings/Foundations must extend below the frost line (36" below grade) 2. Submitted plans must be stamped by a registered State of Colorado structural engineer. A review of the submitted plans will be completed after submission of the requested corrections and clarifications. fohn chumacher, Jr., CBO Chi f ilding Official City of Wheat Ridge Building Department 7500 W. 29' Avenue Wheat Ridge, CO 80033 Office (303) 235-2853 Fax (303) 235-2857 1 poem City of Wheatclge COMMUNITY DEVELOPMENT" Building Inspection Division Plan Review Notes 10/09/09 Spectrum General Contractors 5135 E. 38th Avenue Denver, CO 80207 Project Address: 3835 Harlan Street A review of your submittal documents for City of Wheat Ridge Plan 409-0307 for a monument sign at 3835 Harlan Street, Wheat Ridge, CO, 80033 was conducted and the following corrections to the submitted plans are required: 1. Footings/Foundations must extend below the frost line (36" below grade) 2. Submitted plans must be stamped by a registered State of Colorado structural engineer. A review of the submitted plans will be completed after submission of the requested corrections and clarifications. Cordially, &f*Idi7ng acher, Jr., CBO Official City of Wheat Ridge Building Department 7500 W. 29`h Avenue Wheat Ridge, CO 80033 Office (303) 235-2853 Fax (303) 235-2857 1 ti~0~ W HEgT,DO v mot` 'm 00(ORP00 City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Property Adiltt:sss Property Owner (please print): Mailing Address: (if different than property address) Address: 0q) 33 City, State, Zip: Contractor: ~f~PG~f Lt rv` ri LevLt Ycc c~✓ S 1 412 Contractor License L - Q l 3 Phone: v Sub'Contractors, Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ a ~ Description "ot wo*, ~.t Free 7To w ~i V~ (as calculated per the Building Valuation Data sheet) Plan Review (due at timeof submittal): $ P/ Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENT TIVE of (OVGJNE6) (CO RATOR) PRINT NAME: %'Ae de 7 ) rSSL l SIGNATURE: Date: 'T PUBLICW Date: Plan cncl,--o e30-4- Permit Bldg Valuation: Building Permit Application CERTIFICATE OF,'000UPANCY City of Wheat Ridge 7500 W 29th Ave Wheat Ridge CO 80033 ilPer,mit# 081358 Issued: 12/09/09 Stipulations: Phase II of Rehabilitation Facility" Addition/Remodel This certificate verifies that the building constructed and/ or the use proposed of the building and/or premises, under the above permit number and on ;property described below,; does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met, Site Address: 3835 HARLAN ST Parcel Number: 39-243-00-039 Owner: Sandalwood Partnership 1667 St Paul St Denver CO 80206 Contractor:Spectrum General Contractors 5135,E 38th 'Ave Denver, CO 80207 For the Following Purpose: Commercial' Addition- Cod ditions NO change shall be made in the USE of _ 2003 ICC/2005 NEC this building without prior notice 2003 ICC/2002 NEC and a new Certificate of Occupancy, 1997 UBC/2002 NEC from the City of'Wheat Ridg rinkler,System is ilding Inspector Z nng Ad stra or 7 i IFICATE MUST BE POSTED'BY FRONT DOOR OF COMMERCIAL OCCUPANCIES 12/09/09 11:07:18 City of Wheat Ridge Page 1 bp701-ls PERMIT INFORMATION - 081358 mmackey PERMIT INFORMATION: Permit#: 081358 Permit Type: Commercial Addition Permit Dt: 11/19/2008 Expires: 11/19/2009 LAND PARCEL INFORMATION: Zone Cd: Commercial Funct Use: Commercial Subdivision: Unassigned Cent Type: Miscellaneous Legal: Address: 3835 HARLAN ST Parcel Cd: 39-243-00-039 OWNER: Address: 1667 St Paul St City/St/Zip: Denver CO 80206 DU: 1 Last Zone Dt: Annex Dt: Lot: Block No: 0 JOB DESCRIPTION: Phase II - Rehabilitation facility SetBacks-Front: 0.0 Left: 0.0 Right: 0.0 Back: 0.0 FEES QTY DUE PAID: Permit Fee 2,311,918.73 13,525.95 13,525.95 Plan Review Fee .00 8,600.44 8,600.44 Plan Review Addtiona 191.87 8,791.87 8,791.87 Total Valuation 2,311,918.73 .00 .00 Use Tax 2,311,918.73 41,614.54 41,614.54 72,532.80 72,532.80 CONTACTS: owner Sandalwood Partnership 1667 St Paul St Denver CO 80206 3033992040 go CL1 Spectrum General Contractors 5135 E 38th Ave Denver, CO 80207 3033298003 sub CIA Picucci Electric, Inc. John A. Picucci 2827 W. 9th Ave. Denver, CO 80204 3036287576 sub CL8 Plumbing by George George Hosetz 11901 W 82nd Avenue Arvada, CO 80005 3037172281 sub CL9 Rogers & Sons Inc. Harold Rogers 4775 For Street Denver, CO 80216 3032962999 PARCEL INFORMATION: 10 Structure Type 504 20 Year Built 1962 30 Property Type COMMR PERMIT CONDITIONS: All work shall comply with applicables codes, notes and stipulations All work is subject to field inspection and Fire Dept. approval Approval by Building, Planning, Fire, Public Works and Jeffco Health required prior to issuance of C.O. or occupancy APPROVALS: Req Apprv'1 Date Approver Note Building 10/29/08 Kirk Cadotte Approved per plans red lines and notes. Planning 11/19/08 Adam Tietz REQUIRED INSPECTIONS STATUS: PERMIT NOTES: 11/17/09 Stormwater still needs operations and manual prior to C/O. Drainage cent has been received. 11/19/08 Permit approved with changes to page A1.1, A5.1 and A5.2 that were received on 11/14/08. -AT 11/19/08 CREATED FROM APPL# 08-0302 10/29/08 KC signed off. on permit - still awaiting planning review 12/09/09 11:07:18 City of Wheat Ridge bp701-1s PERMIT INFORMATION - 081358 10/13/08 Resubmittal required. See attached notes. -AT 08/13/08 Given to JS for review INSPECTION INFORMATION: # TYPE CONTR# CALLED CNCL WHO REQ DT INS DT STATUS 1 tce :Temp. Const. Meter 02-2481 12/30/08 no KC 12/31/08 12/31/08 COMPLETE 2 PUG :Plumbing Underground 02-0522 01/05/09 no CCI 01/06/09 01/06/09 COMPLETE 3 PUG :Plumbing Underground 02-0522 01/15/09 no KC 01/16/09 01/16/09 PARTIAL 4 PUG :Plumbing Underground 02-0522 01/16/09 n0 KC 01/20/09 01/20/09 PARTIAL 5 PUG :Plumbing Underground 02-0522 01/21/09 no KC 01/22/09 08/13/58 PARTIAL 6 EUG ;Electrical Undergrd. 02-2481 01/21/09 no MV 01/22/09 01/22/09 COMPLETE 7 PUG ;Plumbing Underground 02-0522 01/23/09 yes KC 01/26/09 01/26/09 INCOMPLETE 8 EUG :Electrical Undergrd. 02-2481 01/23/09 yes KC 01/26/09 01/26/09 INCOMPLETE 9 eug :Electrical Undergrd. 02-2481 01/27/09 no my 01/28/09 01/28/09 COMPLETE 10 pug :Plumbing Underground 02-0522 01/27/09 no kc 01/28/09 01/28/09 INCOMPLETE 11 pug :Plumbing Underground 01/28/09 no kc 01/28/09 01/28/09 COMPLETE 12 she :Sheathing/Sheer Insp 08-0173 03/03/09 no cci 03/04/09 13 MID :Midroof Insp. 08-0173 03/20/09 no is 03/23/09 03/23/09 COMPLETE 14 PUG :Plumbing Underground 02-0522 03/25/09 n0 KC 03/26/09 03/26/09 INCOMPLETE 15 PUG ;Plumbing Underground 02-0522 03/30/09 no KC 03/31/09 03/31/09 COMPLETE 16 EUG :Electrical Undergrd. 02-2481 04/08/09 no MV 04/09/09 04/09/09 PARTIAL 17 COO :COUrtesy 08-0173 04/09/09 no KC 04/10/09 04/10/09 COMPLETE 18 DWS :Drywall screw/nail 08-0173 04/14/09 no KC 04/15/09 04/15/09 PARTIAL 19 PUG :Plumbing Underground 02-0522 04/14/09 no KC 04/15/09 04/15/09 PARTIAL 20 pri :Plumbing Rough Insp. 04/15/09 no kc 04/15/09 04/15/09 PARTIAL 21 DWS :Drywall screw/nail 08-0173 04/16/09 no KC 04/17/09 04/17/09 PARTIAL 22 DWS :Drywall screw/nail 08-0173 04/20/09 no KC 04/21/09 04/21/09 PARTIAL 23 cou :COUrtesy 08-0173 04/22/09 no KC 04/23/09 04/23/09 COMPLETE 24 GPT: Gas Pressure Test 02-.0522 04/23/09 no KC 04/24/09 04/24/09 PARTIAL 25 DWS: Drywall screw/nail 08-0173 04/27/09 no KC 04/28/09 04/28/09 PARTIAL 26 DWS: Drywall screw/nail 08-0173 04/29/09 an KC 04/30/09 04/30/09 PARTIAL 27 ERI: ElectriCal Rough Ins 02-2481 04/30/09 an MV 05/01/09 05/01/09 COMPLETE 28 MRI: Mechanical Rough Ins 01-9993 04/30/09 no CCI 05101109 05/01/09 COMPLETE 29 ERI: Electrical Rough Ins 02-2481 05/04/09 no CCI 05/05/09 05/05/09 COMPLETE 30 COU: COUrtesy 01-9993 05/04/09 no KC 05/05/09 05/05/09 COMPLETE 31 MRI: Mechanical Rough Ins 01-9993 05/06/09 no KC 05/07/09 05/07/09 INCOMPLETE 32 MRI; Mechanical Rough Ins 01-9993 05/07/09 no KC 05/08/09 05/OB/09 PARTIAL 33 FRI; Framing Rough Insp. 08-0173 05/07/09 no KC 05/08/09 05/08/09 INCOMPLETE 34 COU: COUrtesy 08-0173 05/12/09 no CCI 05/13/09 05/13/09 COMPLETE 35 FRI: Framing Rough Insp. 08-0173 05/13/09 . CCI 05/14/09 05/14/09 INCOMPLETE 36 FRA: Framing Inspection 08-0173 05/14/09 no CCI 05/15/09 05/15/09 COMPLETE 37 EUG: Electrical Undergrd. 05/14/09 no CCI 05/15/09 05/15/09 COMPLETE 38 MRI: Mechanical Rough Ins 01-9993 05/14/09 no CCI 05/14/09 05/14/09 INCOMPLETE 39 SHE; Sheathing/Sheer Insp 08-0173 05/18/09 no KC 05/19/09 05/19/09 PARTIAL 40 INS: Insulation 05/20/09 no KC 05/21/09 05/21/09 PARTIAL 41 EUG: Electrical Undergrd. 05/20/09 no CCI 05/21/09 05/21/09 COMPLETE 42 PUG: Plumbing Underground 02-0522 05/22/09 no KC 05/26/09 05/26/09 PARTIAL 43 DWS: Drywall screw/nail 08-0173 05/22/09 no KC 05/26/09 05/26/09 PARTIAL 44 DWS: Drywall screw/nail 08-0173 05/28/09 no KC 05/29/09 05/29/09 PARTIAL 45 EUG: Electrical Undergrd. 02-2481 06/01/09 no MV 06/02/09 06/02/09 PARTIAL 46 DWS: Drywall screw/nail 08-0173 06/02/09 no KC 06/04/09 06/04/09 PARTIAL 47 PRI: Plumbing Rough Insp. 02-0522 06/02/09 no KC 06/03/09 06/03/09 PARTIAL 48 DWS: Drywall screw/nail 08-0173 06/03/09 an KC 06/03/09 06/03/09 PARTIAL 49 DWS: Drywall screw/nail 08-0173 06/10/09 no KC 06/11/09 06111109 PARTIAL 50 MLS; Mesh/stucco/lath 08-0173 06/12/09 no My 06115109 06115109 COMPLETE Page 2 mmackey 12/09/09 11:07:18 City of Wheat Ridge Page 3 bp70l-ls PERMIT INFORMATION - 081358 mmackey 51 MRI :Mechanical Rough Ins 01-9993 06115109 no PC 06116109 06/16/09 INCOMPLETE 52 MRI :Mechanical Rough Ins 01-9993 06/17/09 no CCI 06/17/09 06/17/09 COMPLETE 53 ERI :Electrical Rough Ins 02-2481 06/17/09 no CCI 06/17/09 06/17/09 INCOMPLETE 54 FRA :Framing Inspection 08-0173 06118109 yes KC 06/19/09 55 DWS :Drywall screw/nail 08-0173 06/18/09 yes KC 06/19/09 56 DWS :Drywall screw/nail 08-0173 06/19/09 no KC 06/22/09 06/22/09 PARTIAL 57 FRA :Framing Inspection 08-0173 06/19/09 no KC 06/22/09 06/22/09 PARTIAL 58 FRI :Framing Rough Insp. 08-0173 06/22/09 no KC 06/23/09 06/23/09 PARTIAL 59 INS :Insulation 08-0173 06/23/09 no KC 06/24/09 06/24/09 PARTIAL 60 dws :Drywall screw/nail 06/25/09 no kc 06/24/09 06/24/09 PARTIAL 61 dws :Drywall screw/nail 08-0173 06/26/09 no kc 06/29/09 06/29/09 PARTIAL 62 DWS :Drywall screw/nail 08-0173 07/01/09 no KC 07/02/09 07/02/09 PARTIAL 63 DWS :Drywall screw/nail 08-0173 07/06/09 . KC 07/07/09 07/07/09 PARTIAL 64 ERI :Electrical Rough Ins 02-2481 07/10/09 no My 07/13/09 07/13/09 COMPLETE 65 FRI :Framing Rough Insp. 08-0173 07/10/09 no KC 07/13/09 07/13/09 COMPLETE 66 MLS :Mesh/stucco/lath 08-0173 07/14/09 no CCI 07/15/09 07/15/09 COMPLETE 67 DWS :Drywall screw/nail 08-0173 07/14/09 n0 CCI 07/15/09 07/15/09 PARTIAL 68 DWS :Drywall screw/nail 08-0173 07/17/09 no KC 07/20/09 07/20/09 COMPLETE 69 EMR :Elec Service - EMR 09/09/09 no cci 09/09/09 09/09/09 COMPLETE 70 MLS :Mesh/stucco/lath 09/23/09 no KC 09/24/09 09/24/09 COMPLETE 71 PFI :Plumbing Final Insp 02-0522 10/15/09 no CCI 10116109 10/16/09 INCOMPLETE 72 MFI :Mechanical Final 01-9993 10/15/09 no CCI 10116109 10116109 INCOMPLETE 73 EFI :Electrical Final Ins 02-2481 10/16/09 no My 10/19/09 10119109 COMPLETE 74 ROF :ROOf Inspection 01-9993 10/16/09 no CCI 10/22/09 10/22/09 COMPLETE 75 PFI :Plumbing Final Insp 02-0522 10/21/09 no CCI 10/22/09 10/22/09 COMPLETE 76 MFI :Mechanical Final 02-0522 10/21/09 no CCI 10/22/09 10/22/09 COMPLETE 77 LFI :Landscaping Final 08-0173 10/21/09 no AT 10/22/09 10/23/09 PARTIAL 78 FENCE:Fence 08-0173 10/21/09 no AT 10/22/09 10/23/09 COMPLETE 79 INS :Insulation 08-0173 10/27/09 no KC 10/28/09 10/28/09 COMPLETE 80 gas :Gasline Inspection 10/28/09 no kc 07/13/09 07/13/09 COMPLETE 81 pri :Plumbing Rough Insp. 10/28/09 n0 kc 06/03/09 06/03/09 COMPLETE 82 BFI :Building Final Insp 08-0173 10/29/09 no KC 10/30/09 10/30/09 INCOMPLETE 83 PWF :Public Works Final 08-0173 10/29/09 no DFB 10/30/09 84 LFI :Landscaping Final 08-0173 10/29/09 no AT 10/30/09 10/30/09 COMPLETE O T m O T 9 S Z q n '1 90 2 go S - 3 rn - y 0/ d C d (D d 7 f a * Cl rA co T 3 n1 as O ® Y O ® ~ nm . " r. A Ma W - a f~-n z m A E7 0v 6 Z C) V C m m V ;c - -n w 0 m O m S N y G1 S c S 0 f 'g A a = C > CL > o. o O ( 0 I I C 2 C Nom" N 3 T Q n C tB 0 0 ` -D-I to d O 2 T Q If ? z Z 0 p N Ci) m m r n CD y m c~ p Z 'D co m I O > m c CO) m CD g D L) z r 0 r r a Cl) o m r m az D r m Z u) ~4 G p 6 ? O o z z N w ~0 ~O .Q. j i C Al o Q O O ig DID Es i CITY OF WHEAT RIDGE ~4000/ Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: AID ~ Azwz Job Address: n :3.S IVARZ a, a 57- Permit Number: e~ P/ 6 S? V~rrr~~ !r0~iir!Jsr~~ ~i31r~ Dfg~ ~rl' vl"~ E c S' I No one available for inspection: Time :tea AM/PM Re-Inspection required: Yes No * when corrections have been made, call for re-inspeotion at 303-234-5933 Date: lL,21,76F1~c g Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line _(303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: i Z4 Job Address: 2~ ~E ✓ a ~1 Permit Number: 4~/ I ❑ No one available for inspectior Re-Inspection required: Yes When corrections have been made, Date: Inspector: DO NOT REMOV Time AM/PM for re-inspection at 303-234-5933 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: - F- L- JobAddress: 3qQ ,A : -AA) t Permit Number: c>q1-i5w ( urivAJ NUAc Roo;=loo (-~U Jr yF_~>vT P' A-360t ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No "When corrections have been made, call for re -ins ectlo at 303-234-5933 Date: Inspector: / DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division r' (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax _ INSPECTION NOTICE Inspection Type: PL )M : Job Address: _ ` AR (--Ail_57- Permit Number: DES ~a P?'Fc -T S)NK5 N0i /N501-4 > U SR0Wr_dL Si d. No7 /nJ5)-A-L_rf/3 OU IT- 1 (06, ' /N5 1A-LL Gle113 Alt05 7/1 pU`~/AZ- ?AA 1; ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No *When corrections have been made, calif, r °inspection at 303-234-5933 Date:42-/6-094 Inspector: ~ DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE ' Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office * (303) 235-2857 Fax INSPECTION NOTICE d Inspection Type: , w Job Address/Permit Number: 3r5-!5- p6p E Fs. i' No one available for inspection: Time AM/PM 0 1. Re-Inspection required: Yes When corrections have been made, call for re-inspection at 303-234-5933 Date: ~ 4z'12 inspector: DO NOT REMOVE THIS NOTICE ~ A ..~ ~ ~ CITY OF WHEAT RIDGE P'rn Building Inspection Division !V (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE 0;;'00.1 S-o . /") "- -f- Inspection Type:, -r~~""'~ f)...L' Job Address/Permit Number: 3<ir5'S #~ ,- 1..__ ------ L ..,-rr:': ;?5'-P' lJtX' -r ' ~J,..-I- ~r.J ~ J. ~r_jI f~' -= 11.-. h jp.[J "'" e (11...,<- &> .4// .0..-, -+- . Or "J'<0 u./I'f' n No one available for inspection: Time AM/PM Re-Inspection required: Yes No * When corrections have been made, call for re-inspection at 303-234-5933 _j / ..,---;7 /_,/;;::-;7 Date: y;'~/o~ Inspector: ~/ ~2"c? <2'/ ,,' / DO NOT REMOVE THIS NOTICE \ F , I , ~ ~ I. f f. r f , ~ (, I t ~ , ....~ ~ r" CITY OF WHEAT RIDGE :r;r~ Building Inspection Division !V" (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235.2857 Fax CJ3" 0 <t-:s- 0 INSPECTION NOTICE Inspection Type: ~C f>-o-.",~ Job Address/Permit Number: 3<;;r.r..; rJ", r L--, ~~ ';:r1 A Ii ',_........,.'0 -.+-: -L ~ J: ': __ c~ ' I ,../. # l t t f l I I !l<'J~" I~rf,,:,~ /O"?k AM/PM 11 No one available for inspection: Time Re-Inspection required: Yes ~) * When corre~tion,,/,ave been made. call for re-inspection at 303-234-5933 1. . ...____-'7 ~ Date: ")1 -zyc; r Inspector: ~/~Q-.e_/ I' ",. /"..-/ -. // , c./ ,.- : DO NOT REMOVE THIS NOTICE _._~ --~_.----~----,--_._-~...__..__.--_._._---_.-.~---~._------.--.---.-------------- ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Al -C FI NA C__ Q~ Job Address: Permit Number: PLL41~3 ©f ~u z ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, call f;Vz at 303-234-5933 Date: /b-' / Inspector: DO NOT R EMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE =fj Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: t OOF_ Job Address: MMM9 32 ?'T AA M U 51 Permit Number: _a cj ; '3 1 ❑ No one available for inspection: Time AM/PM ~o NoRs c~Q Re-Inspection required: Yes(o 3_ q~-q 0 *When corrections have been made, call fortre j ; pection at 303-234-5933 Date./ - Inspector: ' € DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: A~?e~,~a~r s, Job Address: _?Px4- Permit Number:, a~ ❑ No one available for inspection: Time 9w,'7,,a: AM/PM Re-Inspection required: Yes No - When corrections have been made, call for re-inspection at 303-234-5933 Date: T_ Inspector: 1 DO NOT REMOVE THIS NOTICE City of Wheat Ridge _rr ►J Commercial Sign PERMIT - 093375 PERMIT NO: 093375: ISSUED:.. 10/15/2009 JOB ADDRESS::. 3835 HARLAN ST '.EXPIRES: 04/13/2010 DESCRIPTION:. Install copy only on existing ` base. CONTACTS owner 303/329-8003 Sandalwood Manor gc 303/629-6121 Fallon Visual Produc 01-8033 Gordon Sign Co. PARCEL INFO ZONE `.CODE: C-1 = USE: C-.1 SUBDIVISION: UA >BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 2,500.00'. FEES Permit Fee 108.30 r „y-, Plan Review Fee 70.40~~,,,,,,~ $ Total Valuation .00 Use Tax 45.00 **TOTAL 223.70 Conditions: AT: ;Approved. KC: Approved'. 10115109 I hereby certify; that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or, regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measureme s ,shown, and allegations made are accurate; that I have read and agree to abide. by all conditions printed on this applicat o and that I~~~$$$some full reap ibil ity for compliance with the Wheat Ridge Building Code (I.H. C) and all other applies 1 Wheat Ridg9~0 dinances, f w k under this p rmit. Plans subject to field inspection. /5 6 S gh tore of contractor/owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building codes of wheat ridge, Colorado or any other applicable ordinances of'.. the city. ? This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. F N1HEgT~/ City of Wheat Ridge Building Division Date: m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ` Fax: 303-235-2857 Plan °oLORP~o Inspection Line: 303-234-5933 Permit Building Permit Application Property Address: Property Owner (please print): Mailing Address: (if different than property address) Address: State, Contractor: Contractor License Sub Contractors: Electrical City License Company: Exp. Date: Use of space (description) ~/Y,1 Description of work: ,~~e~vX Construction Value: $ ~~//l. (as calculated per the Building Valuation Data sheet) I Plan Review (due at time of submittal): $ 411.. YT(_i 1 Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans sub'ect to field in;ti on. CIRLCE ONE(ow CONTR r PERSONAL REPRESE TIVE of (O E , (CONTRATOR) JJ PRINTNAME: SIGNATURE: Datez~D l p DEPARTMENT USE ONLY ZONING COMMENTS: Zoning: Reviewer: p 1 PUBLIC WORKS COMMENTS: Reviewer: BUILDING DEPARTMENT CO ENTS: /-Ot1~ OCCUPANCY: Reviewer: _ FIRE DEPARTMENT:: El approved w/ comments ❑ disapproved ❑ no review required Bldg Valuation: $ Phone: Phone: Mechanical City License Company: Exp. Date: Plumbing City License Company Exp. Date: 4/ V 113!4 " 5'-6 7/8" 1ld" the, N 1 ffilatiorl v;-~tfl,x^ Single Faced (Nan Illuminated) Display Scale: 1° = 1'-0" ra"thick cut out aluminum letters & logo. All Lettering: Painted black Logo: Square aluminum panel with 2 color painted graphics PMS 75170 background with white image. Install on existing stucco wall with a 'W'standoff. Nate: Field Survey for exact wall dimension 1 N r 1 cV -l,V 1 i L f 1 I p 1 f s'-0" 23 Install on Existing Stucco Wall PIN-MUTE ,0 IEMNG OR PLAQUE S0A SLOPED CAPSTOIJE Willi CRITytUQUS DRIP EOq TO MAP BUILDING, INSTALL BA09 ROD MI) SF ANT, GM BY AR011iEGi Sium SYSu Will REVEAES, TtF, CtNIXTE FWNDAiiON WITH P4' CHAllFEEF. EM IND RUBBED RI S'I TOP IF PtAN1TDi GROUND, SNOW, DAS10 FASTIK" ES MIRY PLANTER IN U.EGRIYJND APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date-'V/ tfR j nver 2930 West 9th vel ue Denver. Colorado 303-62E)-61 2 1' Fax: 303.B29 . 1 Q24 E-Mail : Cie ~g c? l3ef-0 y ' IMPORTANT FLED NOTE: - - Voltage: N/A J updeTwrstets Revisions: Account Rep.: R. Frank Client: Sandalwood Drawi g , 11 EabpraFOTIs'l r/ Date: 9/30/09 38th & Harlon 10-10872 + r ~I C GCli , r?uD S r' . U C 1 PA]MAAf cIACUiT~ u- Folder. Sandalwood G d S Drawn by' f. King 1 GORDON J l 'Y M STB DE1 11 USTEEDICATED 1SpiATED C2ACll1TS or on lgn fYl$ets UL File Name: Sandalwood iimonumne+.10872 Safety Requirements Scale: As Noted Client Approval: v - . BUILDING OFFICIAL DATE Mail of permit: The issuance of a permit or approval of plans, s4eificagona and Computations shall not be a permit for, or an approval of, any vio to my of the provisions of the building code or of any City ordinances prasmMng to give authority to violate or wneetthe provisioawciBuilding codes or other ordinances of the City shall not be valid. 6 AV This design is the exclusive property of Gordon Sign and cannot be reproduced either in whole or in part without their consent. Go:don 5.g,, .rl enGcawrla doaelV mdt^h L91015. n-lu. mg PI'M ao;or the e speAii,, . WB cannot cuanote3 ux n1 mAloae4 cue. it) varym @ cd mpa 01% IP SJrtaae male- B'3 and pain's i4so z R) 1 =AZT IMSES ~i oa,(AALL) IFMR W o e.e e o e e e, 1 10_ 1--~- pWNOS: ~PNN®SIWW4 tR. O 4 UM G, PC FIELIdUL O O 9R aGNC, fl1A41 WMY4aR IE fIFL1PoC11 TO MAR DAECRY .To ROAN WM _ 0%INIG. DEFER URBOTE6[tlSRNG pryp{I[wm ntl'S a11o Rdux 9~YfRl M a(d3 DES OW Pnw¢o to PAwlwr 1~ DwD t ER a/Alz AT AT U PWr m 41fl W m :E IJAIXIGfm, _r UIGAMS IMLk m) PEt/AI,I mE UwMe. ' Pt BECMICk mnttMO r f0'%Itl Mm OJJIYN PNXT O sm ma - ww"ur I~ e°ooee mu ; - - - - - mSRnGOOwewrsm xek YN0%m% sxr lD H R cO6ECW IB I ~ " ^..x t i+ § m RP iR or KamPA1 PlnfN 0 RT,104c Af'IMaSD ERE". 'n _ _ AOY6 4 SLm MA91G F.WM' THE MTW6nn11fX - PA.04 IT =15 M.04 ffwl mnvuwrtmm"", ]A=IW4 (V.G/Afx Ar N1 - nM9CW VAPoINGSWlf wm M5KkT TO S[IW.UN ' -...u' YI flmk51f®aa WGTIMS ,'MIX NO I AW3 TYMMHJIM AAS _ _ kn.f-mW RwRwns _ ffWMVNEMw01Et_- - - iWA 9MA1£AWPMIE PAfflIBfT . _ 9MATf kll SL9Ma IW ~ ~ u® Y_ v WiEtTWwsawm @ 11A Hr I J-1 I 9E ""'S 'o - a~ STE R mw ROM IB RMNI mWG IRTIR Pq[ Ili i 8 II; MH MARK HOSKIN ARCHITECTS 1132WA2EESTREETSWIE]Ot DENVER, COLOPPpO 00]02 / / J " TEL 3W1900753 i FAX 30]2900934 e IS'-0 91E TPAO1 AT m"AY 106E HKE FE ammums N MSAAL wOIFA ' ILIL RROttff MNIW MYAIAaE 2NING (EGG'StNSA%K O PHASE 1 PHASE 2 0 N Lu W DO Q K O F z OuJ T~-0 z O J W SID K W z Q ^ ` v! pHIMIGiINN 9SIAGE ~ % ~ ~ 1E RMR NMG AT(E)Wt AND, JOB: (.J ~649~J I, 6F:1/AI.I DRAWN: ED, MAT n'-(rst PoAMf CHECKED: JMA,MEH OOA6RN6E {xFE DATE: 2001 I, fAW N91N WtINWnvrs xaml MAV x'Kx ottff li WEAMDEbmG SHEETTITI-E: Gfni151N01165 1 ONLFXI1A.lTNRIr SITE PLAN OETNR ITE NMAP AN DR TR CASING FNEt REVISIONS: [p51T'G WWRP ORQ :00%CO'S 610112006 On, WIXTE SO PERWIT RESPONSE 1111412006 10 UPDATEDW'S 1113,2009 Q MONUMENT SIGN REV. 91612009. J I I ~ ~ ~iurvw \ I tnmW MA'~aams /I I6Mr 4mIIX i„ O 3 N'Nw116E~W.) r ~~-J WMfR MM' S' RR Ott ff NNGIPoCS E9AxG SERI CAMINP03 WEST 38TH AVENUE SITE PLAN ®pa Atf SCALE: 1'"=20"-0" NORTH L M I/S EL STOP - FRENIY OE tt11WffLl TOOK FwSMG BApIGfWTR11 .1. t NRSSI4W, mat 1. AIL YSTA UNOTttS NOT wall 9 A PNR(E m JOM S RR[kK ImAKU, U RMAIIff [MECim BY MIEA m BE A'NT➢ 6Y OAIf%UIOB( SPMAif [[XIPACI. 9woFR9uu Spur u1 DDTNG CauWS UO RPIxr Mr reRPAVIUmAmlrzn tMMm z nAPI ff IFw w%x 3 WIflALIW m RPM, MY WWE UP XM A1NG F£ Iff TWAY NOT NNm AS A PMT OF H IEw MLR MAT MYP A SVEIY.nADS) M A¢NIECI FOR R { REPAIR ffN1( EWA2 CVfiR 6Y a Y' R' 111 EXISTW W UTS M LWL}NG 311E R~Itt R AE ONIR4IR S TIE OF PROPANE WG TO AVI COI NL MD MD MGNAWA NfAO E ROME E RE RE a Pa 1FI51' X TE HE MEN G uT M 61£X IIIRW ME WRAKIM 9W1 K R.Pd✓~9F FM IAppwl URRAtlJ1011111ES (Pc' !MI 6. "PANIC 9lUL A0Y STMT WR PANDENT EMM RAIE&➢1 IARWeUNDSBRWF(lWAM fEm ANO mW Ga1luN muI RmNam No NsNana 1. NL PERIN UNM1 EA4 B W MI IMYSIM4R) MY AOCS EALAR HE tX1ff IfN6RI Im wo 11 A1.1 A° City of Wheat~dge COMMUNITY DEVELOPMENT Memorandum TO: Accounting, Building file FROM: Adam Tietz DATE: October 29, 2009 SUBJECT: Escrow Fund Attached is a copy of an escrow agreement for the property located at 3835 Harlan Street. The escrow is for landscape area that could not be installed due to inclement weather conditions. The attached contractor's bid from details a total of 1,500 square feet of sod to be installed. In addition, one landscaped island is required to be completed which will include mulch, 1 tree and 8 bushes street tree is required. A check for $1,597.50 is attached, and shall be held until May 15, 2009 or until the deficient landscaping has been successfully installed. A City of iC Wheat 1411 p..9!, COMMUNITY DEVELOPMENT Escrow Transmittal Sheet An escrow has been submitted for the property located at 3835 Harlan Street . The escrow is in the amount of One thousand five hundred ninety seven dollars and Fifty cents $ 1,597.50 The escrow is submitted for: ® Landscaping: Sodded areas along W. 38`h and in-between the monument sign and parking area. Landscaped island on the north side of the access off of Harlan St. being used as a temporary location for trash dumpsters. ❑ Public improvements: ❑ Other: The escrow shall be held by the City until May 15, 2010 A bid for the deficient work has been attached from the contractor. P_/6 Date efts O City of l Wheat~idge COMMUNITY DEVELOPMENT Landscape Escrow Agreement This agreement made this 29 day of October 20 09 by and between the City of Wheat Ridge and Sandalwood Manor (contractor/developer/owner). Escrow in the amount of One thousand five hundred ninety seven DOLLARS and Fifty CENTS 1,597.50 ) is being held until all landscaping improvements are completed at, 3835 Harlan Street In the event that landscaping required by Wheat Ridge Code of Laws, Section 26-502 and/or as shown on an approved landscape plan is not installed by May 15, 2010 the City of Wheat Ridge or its designee shall have the right to enter upon said property to construct and/or install such improvements or do other such work to accomplish that purpose as may be necessary, provided that the City of Wheat Ridge shall first give notice in writing to the contractor, developer or owner of its intent to do so. If the City of Wheat Ridge exercises its right to perform work of any nature, including labor, materials and use of equipment either by force account or contract, the City shall have the absolute right to withdraw the escrow funds to complete said landscape improvements. The only precondition to the City's right to withdraw the escrow funds for this purpose shall be a letter from the Planning and Development Director, stating that the landscape improvements have not been completed or provided and that the compliance date of May 15, 2010 has expired. Approved and Agreed: ontra tor/Develoner/Owner L Print Name Address G Date Title CityW Wheat Ridge, Colorado the Rehabilitation Centerat DALWOOD Landscape Proposal Expected date of completion: Spring 2010 Sod all newly landscaped lawn areas. 1500sq. ft. Colorado Bluegrass. $35 per sq ft. Dumpster area install plant material. 1 Chanticleer Pear 2" 8 Crimson Pygmy Barberry 1gal. 1 Yard supreme mulch Total labor Total Project costs City of Wheat Ridge Escrow amount $525.00 $195.00 $60.00 $45.00 240.00 $1065.00 ' 41~ 5-0 SANDALWOOD MANOR, INC. o6-91 82-101070 7724 PETTY CASH ACCOUNT ) 3835 HARLAN ST. PH. 303-422-1533 WHEAT RIDGE, CO 80033 DlT V ORD6R .ITT o W i-1 PVC-~l`-'il.l Q ,..,-..Q~ . j PAY TO THE OF l - 1 ~rr 3 as 8 'y u /m~ m~ UMB BANK COLORADO' o MEMO 1+ l Ul Y ~PLP. ~~1 -j: 10 700 i067i: 77 2411'6901 i5 i 273n■ ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: s'srm< Job Address: 39'9,f f~AP .lei 5. 7- Permit Number: o 913SM All k';s>7~ev.'l fl Aida 6)~ 'rr:FYt~£~c6J?1F'~ f~;/,rL,~72•'.i> ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes d *When corrections have been made, call for re-inspection at 303-234-5933 Date: zf~Z&e inspector: e' DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax " INSPECTION NOTICE Inspection Type: Job Address: Permit Number: 19 ❑ No one available for inspectior Re-Inspection required: Yes fi *When corrections have been mad , Date: Inspector: DO NOT REMOV AM/PM ispection at 303-234-5933 NOTICE ♦ i CITY OF WHEAT RIDGE r-~ Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: /;yA.r , Pte: g- A6F Job Address: 3~v S 1~a~k.~s~s ST Permit Number: Af mli,: o Re-Inspection required: Yes 4Rto "When corrections have been made, call for re-inspection at 303-234-5933 Date:3T1-e?_ Inspector: r DO NOT REMOVE THIS NOTICE INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS BATE INSPECTOR INITIALS COMMENTS: Footings/Caissons Stemwall/ (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines CONCRETE SLAB FLOOR '.Electrical (Underground) Plumbing (Underground) Heating (Underground) ROUGHS Sheathing Lath /Wall tie Mid-Roof Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED I I DO NOT POUR FLOOR UNTIL ABOVE HAs BEEN SIGNED Framing Insulation Drywall Screw e~ x r~ , F; . OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER I In, FINALS - Electrical G .2 Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage START ALL ROUTING ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping *`NOTE1. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED.' FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE i i { f I ❑ No one available for inspection: Time 4:1P AM/PM Re-Inspection requjred: Yes No When corrections have been made, calf~~for re-Inspection at 303-234-5933 Date: 46,-:4 Inspector: DO NOT REMOVE THIS NOTICE Inspection Type: At♦ls ® AV'la-, Job Address: 355✓ S1 Permit Number: 05""13$ ' ♦ ♦ CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: at,/S- ,tAA72214Z Job Address: J '00S tf l4al ST Permit Number: o;?1. 53' ❑ No one available for inspection: Time A'90 AM/PM Re-Inspection required: Yes No "When corrections have been made, call for re-inspection at 303-234-5933 Date: 1,9Inspector DO NOT REMOVE THIS NOTICE 1ST Z Z02- W-Aw / s I A, es o Fs.1. ;t a f.1,111 ff-- / 3 cr ♦ ♦ CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: DWu 5 - i0ARVIA Job Address: S7 3~~z2~✓arJ sr` Permit Number: 0919 SZ t'~i( 7`lc'uS5',?/~'~L4- f~' d~~t'!C su.~L,~',~.:'7/~ rya ~.~'fu✓ ❑ No one available for inspection: Time ,'/a AM/PM Re-Inspection required: Yes No *When corrections have been made, call for re-inspection at 303-234-5933 Date: e,l:72r 291 Inspector DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax 1 INSPECTION NOTICE Inspection Type: / Sv1.f?ianl r° P.4onw Job Address: s7" Permit Number: eP£ e~ /ry /h°~ieyiEu✓ r/~2 y+ Jtis~ ~r rdV se w ®;F yf r~ 6i3d/ ®f ~av ~vraiov vr~ ~or>/` C~>7iPe~/ - flc l ~k l ❑ No one available for inspection: Time ~s AM/PM Re-Inspection required: Yes No r When corrections have been made, call for re-inspection at 303-234-5933 I Date: Z y-1,09' Inspector: I: DO NOT REMOVE THIS NOTICE f' ♦ ♦ CITY OF WHEAT RIDGE -,w Building Inspection Division (303) 234-5933 Inspection line '40011111 00 (303) 235-2855 Office • (303) 235-2857 Fax 1 INSPECTION NOTICE Inspection Type: 4z.~ '3a'~/!a/ Se Job Address: Permit Number: 091359 ❑ No one available for inspection: Time T >5 AM/PM E f Re-Inspection required: Yes No r When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Bung Inspection Division r000or (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: DiAIS Job Address: 5975 ~2d f 57 Permit Number: 62?1359~ S l~~' !ST-~A,¢✓~'d2 c"..~,+€!1 ls%r¢1r E%va~.r --~t~ asT`d ~vf~ Irv Q&P -PY7- L,4~~,E+s!ii dY✓ ,rfa~u'.dt-+713/TiOrrl ❑ No one available for inspection: Time p®>"+S AM/PM Re-Inspection required:< Y_ No *When corrections have been made, calf for re-inspection at 303-234-5933 Date: /Z Inspector J , DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office " (303) 235-2857 Fax `cl INSPECTION NOTICE Inspection Type: r' / o Job Address/Permit Number: e__._ - ❑ No one available for inspection: Time AM/PM Re-Inspection required: No When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: g- l / DO NOT REMOVE THIS NOTICE i 4' CITY OF WHEAT RIDGE Building Inspection Division 1 .0 (303) 234-5933 Inspection line (303) 235-2855 Office * (303) 235-2857 Fax INSPECTION NOTICE r Inspection Type: mt) ~ ire raft Job Address/Permit Number: ~Et,t r 't - ❑ No one available for inspection: Time dM% M Re-.Inspection required: Yes 60 . `When corrections have been made, call for re-inspection at 303-234-5933 a Date: n. /?-f? Inspector: V DO NOT REMOVE THIS NOTICE ♦ , i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: n4R/ Job Address: .:?8'25 I.IARIAfl 5r Permit Number: e~2x'1358 -4107 ° . 779/ 57 15 _7,01-5 t~sy wl A rr . ai~cr Jt a F aryS6fxr~sS 9/1-J 8'iL KC/VW~('.13" ! : rz'i.K 1 A'9 OUJI~fCd7~/ >7/r i ❑ No one available for inspection: Time AM/PM Re-Inspection required: No g` When corrections have been made, call for re-inspection at 303-234-5933 j Date: 6. f14~107 Inspector: ee DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Job Address: ;r~~r * x" fLe_~gc~!4~ Permit Number: 6~f ❑ No one available for Date: Inspector: _ DO NOT REMOVE Re-Inspection required: Yes No "When corrections have been made call AM/PM re-Inspection at 303-234-5933 NOTICE A ♦ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-59331nspe00017 line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: n s ,l~ - d~A~ sr~L Job Address: ?&3S AARLI. 57_ Permit Number: e~~l3Sfs' rer c frL7Di7/ZJnJ iFs7 r 2 rr~Q Al /7112 Z W r+ lz ~Xta' i As gt /~c~ a~A w~ r r~ E:- ii f. " I" e, H t ❑ No one available for inspection: Time h AM/PM Re-Inspection required: Yes No *When corrections have been made, call forrrre-Inspection at 303-234-5933 Date: 1/r/ Inspector P DO NOT REMOVE THIS NOTICE SPECTRUM GENERAL CONTRACTORS INC. 5135 E. 38th Avenue Denver, Colorado 80207 303 329-8003 Fax 329-8032 June 8, 2009 John Schumacker Wheat Ridge Building Department Mr. Schumacker Please extend permit number 081358 for Sandalwood Manor addition, located at 3835 Harlan St, as the project will not be completed until November 2009. Thank you K ~iLr a a Bochy Operations Manager A pwrvwd Ud 1 II]IGl vc~~j Is u~c~ tI I~ o 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office '(303). 235-2857 Fax INSPECTION NOTICE Inspection Type: OWS - AW;rMl Job Address/Permit Number: ?jE35 WAA/ sr, eDPV3s,12 a eA~9 3`-h= x/s ~S d~ sdi 72m . r'S a ❑ No one available for inspection: Time L,-z AM/PM Re-Inspection required: 'Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: a Inspector: G~ DO NOT REMOVE THIS NOTICE 06(01(2009 07:26 3035769788 MAGNUM MATERIALS PAGE 01 ibPRAGES i" 06/01/2009 07:26 3035769788 03 Rdsm Frohman MAGNUM MATERIALS PAGE 02 °.lun UI 08:03a _ 303-499-0226 P,2 A AMERICAN June, 1, zals TO Whom it ::sy cone ri. American Gypsw'" 5: $ typc X board is wm13fiHo1 w:th GA 214 spccificatzons regarding; a maximtau spec: g of 24 i acbcs on toter when used in either parallel or perpend culat to framing in a ceiling "Application. wb z a scemtd layer is applicd perpendicular to the is will still rtc:ct sag; staudards sct forth in by the gypsta., association. If you have my oL-cr qucstionti please feel Kee to call me. +03-775-41867 inankc Adam Fmlttnan ~ ♦~~41 V, CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Ds' ~P Job Address/Permit Number:.;19~5 9sl.~h.9YAAs xa°" 935 VP r w m~ ~r aaB ~ra~.~ ~,,Rrd a.yrd sLs>. bya" 05- f~/rFi/S ar (tlsJ,7S u/S57'o .~1r5?: r~ ~l/ -Xae ❑ No one available for inspection: Time moor AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 i Date: 0'17,/ Inspector: ~ DO NOT REMOVE THIS NOTICE ,r ♦ ♦ CITY OF WHEAT RIDGE ~-r Building Inspection Division ~ (303) 234-5933 inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: c r~ Job Address: 5 lz. Permit Number: 2 7T 12k -r~ rl~ e t s ? ~i I C: r E_> L;, o ❑ No one available for inspection:; a AM/PM Re-Inspection required: Yes "When corrections have been made, ca o e inspection at 303-234-5933 Date: `co inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 12te/5 °.%1h1~ajXZ Job Address/Permit Number ga 3j PSyr'*s/£ .,%r.4>,'G"..+tiJ'eSl7sZra° ,P'~. r<,ti.~,sdPJ:f.~✓irer..h'rr? gar=a~ - ~,..-~cr y~7"rr:~rsr:c ..,aar.~frs ,u.~fr?tom ~.vrv~ ycw~a-brz~ ,s ~~~~Sr_4 :7r~✓>re5i /a!.~ ,1_; n_ ~ r~ t-~ fi2 ,~,e' lq AWfA/.h..4,-9 1P'ayw h"°-±.4`-_r- 7; »CS~~jp~rvi s~r5 ✓F~T~*` \\..,~i~'Y ~i✓JJy ~1.`sdd /'efrl % ~,+~~0/V /'?i3:.'i ,~la1=`L. {s } .S~~flff21'`Y"~ KJa`£ 3~. {~92G7. `/.F•dt 4~'A<f X/"iL'G% f','.!7` .+d/yL% r ❑ No one available for inspection: Time ar✓,'>~ AM/PM Re-Inspection required: No .When corrections have been made, call forr~ re-inspection at 303-234-5933 Date: 4/g9,/p 9' Inspector: DO NOT REMOVE THIS NOTICE ♦ ♦ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: G tas w / 7.~ VF e Job Address: 3S',3 g4,o/tai < _ Permit Number: erns ~A,2,?li/y/_ r7a -;>Z<i~S~<_ fGr~~ f -rs ~ ~ . oel,yy r^ ¢ , n S ~ .L Sa'lGa7` ~.e.~ J~ L rrr ° 9~ /l - vs2 L-"// s//iA 725 ~ r ❑ No one available for inspection: Time AM/PM Re-Inspection required: . No *When corrections have been made, call for re-inspection at 303-234-5933 Date: s' r~fr~ Inspector: N~ DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: ~~c^rrc f Job Address/Permit Number: rs El No one available for inspection: Time AM/PM Re-Inspection required: 'Yes When corrections have been made, call for re-inspection at 303-234-5933 Date: 4~ mil/ r; Inspector: t DO NOT REMOVE THIS NOTICE `►l;4' CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE iF~~ri~dl> Inspection Type: & PAS Job Address/Permit Number: 39.6.5 AAVAg137-. ❑ No one available for inspection: Time 9,'0 AM/PM Re-Inspection required: : No When corrections have been made, call for re-inspection at 303-234-5933 Date: S 117 1,97 Inspector: ' f- DO NOT REMOVE THIS NOTICE i ♦~~4' CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Job Address/Permit Number. & 42 4,1 ❑ No one available for inspection: Time AM/PM Re-Inspection required: 'Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE Inspection Type: fe Job Address/Permit Number: S I r• a. v G ❑ No one available for inspection: Time AM/PM Re-Inspection required: 'Yes r l 'M I "When corrections have been made, call for re-inspection at 303-234-5933 5 Date: ZP /g Cf?X nspector: DO NOT REMOVE THIS NOTICE ;C4' CITY OF WHEAT RIDGE 35~1 Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Fr._. Job Address/Permit Number: 5ss rs Ile t 5 ❑ No one available for inspection: Time -S-k Re-Inspection required: No When corrections Nave been made, call for re-jnspecd6 - Date: Inspectors DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE F Inspection Type: zf Job Address/Permit Number: Re-Inspection required: ej No When corrections have been made, call for re-inspection at 303-234-5933 r Date: Inspector: P j DO NOT REMOVE THIS NOTICE -;1 ~114' CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office " (303) 235-2857 Fax tSFf / 3-j"~S INSPECTION NOTICE Inspection Type: x= G r! r 'i, Job Address/Permit Number ❑ No one available for inspection: Time AM/PM Re-Inspection required: (De I No When corrections have been made, call for re-inspection at 303-234-5933 I r Date: 5' Inspector: DO NOT REMOVE THIS NOTICE fi ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: mkt 4- Fk P/3 rl,41 Job Address: gVgS V,446441 sr Permit Number: ry 0135"S ❑ No one available for inspection: Time AM/PM Re-Inspection required: f6e No e "When corrections have been made, call for re-inspection at 303-234-5933 Date: .5-1gleP Inspector: xe~ DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Z4-u CU 4:~:i 6K ❑ No one available for inspection~jime AM/PM Re-Inspection required: Yes "When corrections have been made, A// for rip-inspection at 303-234,5933 i Date: Inspector: ! i DO NOT REMOVE THIS NOTICE Inspection Type: 45~~~/ Job Address:' t Permit Number: / ~~~'S,~.p ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: I e- c_ Job Address: 5c e r v 1 Permit Number: t, F ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 I Date: J Inspector: I'V C-,t_ DSO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Qv-JS - A0 7-1,4L Job Address: 3635 IIAR, 1-y Permit Number: 62'9 j S a' 74- PP,IAIZ /Si4 2 aryl/s'0_F '0~1 {)'iTy° i .z✓ ❑ No one available for inspection: Time 14?;,XO AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 k f Date: O O~ Inspector: DO NOT REM E THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: I?W-<-,,04P, Tr,4C Job Address: 3$3Sri2~sCJ Permit Number: ®3/35,,-7 i°T r'~fG aEB S dz1GZ ~fa771,uV /,7is?:1G 7- d'?srv,wG e2~-rDrr~ e~sL ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No *When corrections have been made, call for re-inspection at 303-234-5933 Date: c ~S1v7 Inspector:. ~ DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Vi,,,S P4jcr~L Job Address: 3 03 < 1-14,;eZl® _Q' Permit Number: 0 Si 3 5~9 ~2s 19 7- /l-~.si~ - n 11 ~~f °~M?~, ct !d~ -rdt /5"7- El ,~31 S7i.' !i J/tJ/ldC~ No one available for inspection: Time so ; 3o AM/PM Re-Inspection required: Yes No "When corrections have been made, call for re/-inspection at 303-234-5933 Date: e/ e'/fc y Inspector: DO NOT REMOVE THIS NOTICE ♦ ♦ CITY OF WHEAT RIDGE ~-#.w- Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Qw5 -,04877,4` Job Address: Y$:-5 1W4, 1Lo Sa Permit Number: lJ a i 3 5P t S?"~~rm ~-r~.~ t~r~ a~2r f I3i~~avL i2rao>~ Y J~a aa~T~~.~/~ ✓raQJ77'3'~~ ❑ No one available for inspection: Time ,S AM/PM Re-Inspection required: Yes No *When corrections have been made, calf for re-inspection at 303-234-5933 Date: Y IT '7 Inspector: , 11 DO NOT REMOVE THIS NOTICE ♦ A i CITY OF WHEAT RIDGE Bung Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: o0j,)6d, . ART Job Address: ii_-; AARLALe sr Permit Number: p 013S191 ✓vVY- °320 f''Fi inJ/ Pn~ ~7/1®e~s/~ ~{r~[`f^~ /~G. /<.sr y' ,mod S~~"r~ r~lC E t ❑ No one available for inspection: Time ,rrr 3,;, AM/PM Re-Inspection required: Yes No `When corrections have been made, call for re-inspection at 303-234-5933 Date: 5 og Inspecto~ DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes When corrections have been mad / 4nspecti on at 3 03-234x933 Date: r U Inspector: 1 DO NOT REMOV~ THIS NOTICE Inspection Type: G-°r_ Job Address: k f = Permit Number: 6~ 5 MHA MARK HOSKIN ARCHITECTS February 27, 2009 Mr. John C. Schumacher, Jr., CBO Chief Building Official City of Wheat Ridge Community Development City of Wheat Ridge Municipal Building 7500 West 29th Avenue Wheat Ridge, Colorado 80033-8001 Re: Phase 2 Building Permit Response Follow up Sandalwood Manor 3835 Harlan Street Wheat Ridge, Colorado Dear John: This letter is written as a follow up to review comments issued October 29, 2008 with the building permit. All responses attached and referenced here have been forwarded to the general contractor to become a part of the construction documents. 1. All foundation work shall be inspected by the engineer of record and shall include the perimeter drain system. Response: The foundation work has been inspected by the engineer of record. Per the attached email correspondence with the Geotechnicai Engineer and as coordinated with your office and the general contractor it was determined that due to the elimination of the basement and the fact the no portion of the floor slab will be below exterior grades that a perimeter drain would not be required. 2. Provide detail for secondary roof drains on flat roof areas by the time you are ready for the plumbing rough inspection. Response: Attached are sheets A2.3 and A5.2 with details and elevations of the mechanical roof drain channels. These areas do not create an enclosed well therefore it is our understanding that no secondary drainage is required. 3. Will need to install fire blocking every 20 lin. feet along all soffits through out the perimeter of the building. Response: Attached is sheet A7.1 noting the required fire blocking requirement. 4. Provide a water flow chart on roof system showing that a 4" gutter will be adequate in lieu of a 5" gutter. Response: Attached please find the mechanical engineers response letter and water flow chart concluding that the 4" gutters/downspouts are adequate. 1732 wazee Street Suite 201 Denver, CO 80202 tel. 303.298.0755 fax. 303.298.0934 www.mha.bz We trust the responses attached will satisfactorily meet the requirements of the comments presented. Please do not hesitate to contact us for any further clarification needed. Sincerely ~4 cc: Richard Whelan-Sandalwood Partnership - Owner Tom Cella Spectrum General Contractors - General Contractor Mark Hoskin_Mark Hoskin Architects - Architect All project consultants. Page 1 of 1 Joan Anderson From: Rethamel, Bill [BRethamel@CTLThompson.com] Sent: Friday, December 05, 2008 4:56 PM To: joan@mha.bz Subject: Sandalwood Manor-Drain system and entry slabs Attachments: optional.drain.fig.pdf Joan, Per our conversation this afternoon, we understand the project has been revised and there will be no basement for the addition. The addition floor slab will now be at grade and no portion of the floor will be below exterior grades. For this condition, perimeter drains are usually not constructed. A drain may be installed to control likelihood that water will collect in foundation wall backfill; a conceptual detail is appended. Regarding the entry slabs, we generally recommend exterior flatwork and sidewalks be separated from the building to reduce the risk of transferring slab movement to the structure. Although the on-site soils generally pose low risk of heave, we recommend constructing the inner edges of the flatwork on haunches or steel angles bolted to the foundation walls and detailing the connections such that movement of the flatwork will not cause distress to the building, rather than tying the flatwork directly into the building foundations. Construction on haunches or steel angles and reinforcing the sidewalks and other exterior flatwork will reduce the potential for differential settlement and better allow them to span across backfll. Let me know there's anything else I can help with. Take care, William D. Rethamel, P.E. Project Engineer CTL I THOMPSON, INC. 1971 W. 12" Ave. Denver, CO 80204 303-825-0777 ext. 282 phone 303-825-4252 fax www.ctlt.com Information contained herein is neither necessarily complete nor accurate. Final stamped and signed documents govern. Use of these data is solely at the user's risk. By accessing the data contained in these files, the user agrees to indemnify, hold harmless, and defend CTLIThompson, Inc., its employees, officers, and agents from any and all claims arising from the use of the data. 1/19/2009 MH ~I ~6p~A mr tale0.5¢x0 ulm MARK HOSKIN ARCHITECTS 9MO AI HIIAIQA%510 N' -J' dW'~4W KA M6 YY 04 N 1393WO EESIflEE]S M201 Y% Ri166d11P 0/R HON12 D~ . p~-~m~~l~l IEL ]03.]9B.N55 FAY:3033dS09M p m-wm 1NVa 1a {H-IpFp IIfr PM111MM1 R~pM9101 `PI XYp-901.NEYU PMIp -~-IU tgMm iAl p. i-19 _ rrs+wmlx vwrlNlExl s DETAIL 4A SCALE: 1" AWIN190NkS m Al K`R%RI SUR N YIIIM W. WIRPJNS 5RV M9nW l1 VLL I&1Y'O Ifl lYL 1q1~ y-I) iMC1L ~i[ ASI d Ry I IlOE LR ` 4WE~ 1:13 Il~ - MINT - Imwa-.m sBwR mw 1YIw YF O Z a o NW0 OW No OaQW 2=~ ~A MQ ' LL ~ W a r) Z a U) 011 3 JOB: 829 DRAWN: M.MAT SR P CHECKED: JMA, MEH Wl IN9T WI DATE: 887 KW US W Ilp qp{ of SHETRE: 12 I II I j s ROOF PLAN I - `•v. o II ~ m ~o P° wpM1OEaox xxluew t O ,sp I au%mIWSmm~W % °i nWREWF REISIONS: p p V90 Im%.S W07aWB r 1111VMB / O / FFI ffMSCN5E IpIMom. / A U.OTEDWS 111Y2009 / N9 P WWI ` yO/ 426.M O1IX M. bO O R / I#iu9(7 (MI4 dIRP / Wq WN3J1R 0.lOt BY ~ / / NMRCL WAiuR ' / WFJ911 tfUW6 aPoPRR NMI W46]YUIgL. AWINI9YYJ[5 w 91 xooow NIL Nm .x CLLR." sm AY AONR[r Irol: wa xnr t_n' wl A-w wn reu xM Vlna ueax IX_1,A' t;iMYIXw ^ a41VPA 70.a7 .X i ton _ ^ 61 x ~IIwS / sIX Su !EAST ELEVATION 9mE / WIMP P ia RIM 0 Q14XIIVlA ~ / I u[1u 11.19P&N Y9AIIVIS xL mIwWILS 1p1 w alxmn. ~`vsa valor ~~axxnnas Saw a.VIa41UM1 1 `'1 xM [PRL LNHRPoY DID 1 A,NM1 RV 5@E Pl / 9 WALL SECTION As.2 SCALE: 3/8" = 1'-0" Y_0. AI a-a Mn 9st xM YWl6N ,L R M¢ w' pf-f I/T !-3(rnFYwOw A9I wlr$ 0 maa area-uvl ar &Mw WA R0 4/LN'1. 191i Y19a1 W: UlY1W6 IX X17 M1 SRIW SSRY p w) "Ex Uw aKP O'WXIIF INE, V.Y M. RA. asm[ MRarz mw9mu w IN uwmma ww mm9a vulva sMVn Alma-xM wn) p ls cwF. a: [I[vAMriPo ~ ~ ~m~ 1 I Y a-'§ ^ 5@R 9l a w sw wnM Iwmla x/rs x¢Iw Pn RY[ NR Fm N Y.1101 tlYSNI as wM IO @RRAV PpIM p{YIIIWI AST ELEVATION a.MS. blT MH MARK HOSKINARCHRECTS t DMEREE. SiPEET5U OENJEP WLOINOD WV. Y02 iE1:3P]1960T55 FPX ]N]9B.09N ryo O Q O OW NO O W (n 5 K~ ❑ I -w w Q z / U) I JOB: 629 DRAWN: ED. MT ® CHECKED: JMA.MEH DATE: 2007 ``1 MAR 9V9fl0X 1 iw fq. pL lJ.l SHEET TIRE COURTYARD NORTH ELEVATION ELEVATIONS )o WALL SECTION Ass SCALE: 3/8" = 1'-0" REVISIONS: / 1W ors WOMO08 FE9MRRFSPw15E 11/16Y1000 MRU]RiL2 `kxl _ _ Ia IN3 10 MA.MS 1/132009 n6i~ ~QUEMA 6. 1A RARh i as MOaxs4Rn7 rtw iafg$ T RQ-V Y li SUIVR IIpCIJ wN R: JU ~ M I WEST ELEVATION PLAN DETAIL ws.z SCALE 1 112 = 7'-0" - Iz ~A 9ma ASNN1191w(Sf5 01W 111 50JING Rl MM ILL PNV NAIIX 911FI0101.RM.VP Mo D. N Nx Bxmlfo uLlu RAE 41q 4NNIL [CNMJM TO XTDTTR xuofmc y. ID fXM, mKKIWR F R: Ael Lm fIRHI " ID SIAVCNW FOR ROOF 1RM7/ r, 9LL W RLWS M'S 1WALL SECTION ftl 13 -l A R.D. Rf E1 119-6 ` $WFlT VLNT p8 K.Rs RM MCMm Ra CmI vw AXD 4AL+xr wa3 Du i6 9LL PAR P9E-NNS4a 1491 11 RVL1l T(HQT)P Vr. MOTT a ROY - 1 ' PAN 1 wA .1 aw.w M'D Vxl R3 11 HVAL CV[1 sUPPmRO C ,R. ROOF CRTUTSOTES MIFfxLRm3R~ 6 CHNNNVCm 4NAXi - BpE WLY MITI RE WCK mS iP2 a1CPPfD gN6 T 1 ` O . HFa1 ylFli 4RANAlE IIGa CA4C aID JAPE - N%E: PRVVWE D..8.. D 5 NpENXG MM I L g RR R a xEAO EXTENDED cmu pMRRfIA91WL S.I. 5111P, ltl RWMPfR5L1WWC- IXFRAW- . 0TO.T CUM mWM141 .M. WL 105161C - R-19 &TT MUL I/ - VMm mu Y4L W PER smEDNE - sLL REX 1LWI6C RR S)EDUIF ~ J RLgI A R PER L20RCI m N IKP,C x Ew"oR 5mv w/- .Ml YNANL 7 CmRWa52' RM Pff E"N %VRm DIEND 3<' 'hAIIWLY WALL SECTIO N a AT.1 sLLLC 1/3' a r_a• Rf- R-N BAR M9ILOAM - . GOIO AvD JAVB H0R FALKf NEW.3W& M90 SLL RAwnc wM mnma xLAO RAWxG u'o fxk mmwxiLA9wc sl1s, 1mL4 P-19 VAll H91L Y/ Seem T.M VMYLY9 .G "AT MAL WALL SECTION I/2• , L_0' 0.9114r 9YXQF5 UAI YJI BIIILLYXi 16L %W E 10 31 PA51 ME NIf114LHp1 FTC IX.M 6 AI TIE RW wxL uU aP: flJ}', 11PIV1 (IW.) R2-.M w fIX£ PK-RM91fD A' TOM N/ as n-f4 2AL~ 1ffIIJfA Ra I~ To IIJ'-s Y' t0.9LL 0.Q i IIJ'-E Y' R6 SINIF 9LL MHA MARK IMIN AROHITEOTS 1]32.EE.EET5111tE4l DENVER.COLORADO HDA3 TEL-, 393~9e.o2ss EAx3ou9H.mu ry O Z O 0 N Wo 00 0w,- O I ¢w -1 0 Q wo0 =xE! ~aMW J ; IL Z VJ VINR NM A% C ~ =T& FROM MW0.IDAR YW]&O}IIIG 10 . Tf NQT UU1Uf InSrNIA➢m JOB: 839 RaI9fND11$I1P ORAWN: ED. MAT CHECKED: JMA, MEH RD IEONA x V ~ DATE: 200] a rs lag'- fM SrHN MIma STOW SHEETTITLE: HE-P96y Mla MXI WALL SEC TIONS flW-PR®1pW xOl la PL NM fltq ND aEP @Z Bt ST uMl6 L0.m YY Ec Ng12C1 - REVISIONS ER. D xm A4 .sT,t 100 I SEUR am YNA4i. UlOl Ar A9WR<r 1 S 811112008 KRTAFT ffAMR PE8FV115E 1111412008 10 uPNAreoms vts/2009 " Q 1 r Hr NH LKK X.M-T3 XEAMfA P{X 9fAMXG aLIYWa SCORE z AA411APoKcxT - fRRNO Ip C Iltt 10 m (IIXN A j0f-tl~ VIII .i 0u9 GR~HiL IF fO3ML RA SIM1IICMY SECTION 7 BELFAY ENGINEERING, P.C. Mechanical & Electrical Consulting Engineers 2811 West 9" Avenue Denver, CO 80204 email: belfay@belfay.com January 5, 2009 Kirk Cadotte Combination hispector/Plans Examiner City of Wheat Ridge Building Department 7500 W. 29`h Avenue Wheat Ridge, CO 80033 Project: Sandalwood Manor Project Address: 3835 Harlan Street Belfay Job No.: 08045 Log Number: - SUBJECT: Response to Plan Review Comments dated 10/29/08 Mr. Cadotte: TEL: (303) 892-5980 FAX: (303) 892-5979 Below I've addressed the item you've indicated must be resolved upon the beginning of inspections. Plan Review Comments: Comment #4: Provide a water flow chart on roof system showing that a 4" gutter will be adequate in lieu of a 5" gutter. Response to #4: See attached 1 lx 17 of the roof plan which shows the locations of the downspouts from the gutters and the areas of the roof served by the downspouts/gutters. From table 1106.6 of the IPC, a 4" gutter can handle up to 960 square feet of roof area at 1/4" slope. Per the attached drawing, each section under 960 square feet is served by at least one down spout and the sections over 960 square feet are served by two downspouts. Therefore, the 4" gutters/downspouts are adequate. This concludes our response to the hold-item pertaining to the plan review comments. Please feel free to contact me if you have any questions. 2279" m 5 -6, I I I i i ~ t \~0 SF \ I / -I / 590 SF 895 Sd ~M r r ~I 736 S 84, I r i I ~ IIII i F I / I ~ 96Q j i I MHA MAWCHDSKINAR HR.= 1TRW0..F.££)HC~lSIllIE5r1 oErrvEn. axozwo arov TEL: wsxeawn FfK 3p320fl4${C 0 z qC 0 ~No C)W o o< w ec ~n Ww , w Q 3 z CO DRANN:' M. MAT CFgCIR'D:' w, MEN DATE =7 6HEETTtRE " ROOF PLAN R MONS wm ws almaooa fil6Nft✓ DNS= llfl lOOS Y~ r ~3 ~u0~ 2 j H Q• B O Z - o O y rn Orm y iv imp vyai .fTl tD--- Coll) p m 2 N aN N ~ Q 7~ 4 o 3 d 2 Y b o m ° ~ o~ r4 CZ) V o IpI \ m N m n z Na f :1~ O mm p _ to N ~ N•~ z 'f YY O O -I T -1 ~y MM m O ref sm; ~ m A -C r O COMMUNITY DEVELOPMEI pEPT. Inspection Services Division (303) 2345933 Inspection line (303) 235-2855 Office CORRECTION" NOTICE ❑ Elec. ❑ Plumb. Mech. ❑ Structural 0~"Other P` ❑ 1st 2nd ❑~3rd a Job Address: '2ya ?c 7 t",}` t r ,q ❑ Re-inspection fee of $ must be paid prior to re-inspection. ❑ Blocked Access o No one available for inspection: Time AM/PM *When corrections have been made, call for Se-inspection at 303-2345933 f f_ 1 1-7 Date: Inspector: DO NOT REMOVE THIS'NOTICE r, -C, RT &IC, TR 6~JST BE POSTEb Bl ERC)NgF DOOR O'F ' COPQMERC SAL . OCCTJYANGl~ 03/10/09 10:47:27 City of Wheat Ridge Page 1 bp701-1s PERMIT INFORMATION - 081138 mmackey PERMIT INFORMATION: Permit#: 081138 Address: 3835 HARLAN ST Permit Type: Commercial Addition Parcel Cd: 39-243-00-039 Permit Dt: 09/30/2008 OWNER: Expires: 03/29/2009 Address: 3835 Harlan Sr City/St/Zip: Wheat Ridge CO 80033 LAND PARCEL INFORMATION: Zone Cd: Commercial DU: 1 SetBacks-Front: 0.0 Furst Use: Commercial Last Zone Dt: Left: 0.0 Subdivision: Unassigned Annex Dt: Right: 0.0 Cont Type: Miscellaneous Lot: Block No: 0 Back: 0.0 Legal: JOB DESCRIPTION: Rehabilitation facility addition O nursing home FEES QTY DUE PAID: Permit Fee 895,623.62 6,651.23 6,651.23 Plan Review Fee .00 3,736.82 3,736.82 Plait Review Addtiona .00 586.48 586.48 Total Valuation 895,623.62 .00 .00 - Use Tax 895,623.62 16,121.23 -=16,121.23 ~2T095.76-- 2.7,095. CONTACTS: owner Sandalwood Partnership 3835 Harlan Sr Wheat Ridge CO 80033 3033992040, go CL1 Spectrum. General Contractors__5135_E 88_th_Ave Denver,CO_ _8.020_Z .no CLA Picucci Electric, Inc. John A. Picucci 2827 W. 9th Ave. Denver, CO 80204 3036287576 sub CL8 Plumbing by George George Hosetz 11901 W 82nd Avenue Arvada, CO 80005 3037172281 sub CL9 Rogers & Sons Inc. Harold Rogers 4775 Fox Street Denver, CO 80216 3032962999 PARCEL INFORMATION: 10 Structure Type 504 20 Year Built 1962 30 Property Type CONNR PERMIT CONDITIONS: All foundations must be inspected and verified to the building division by wet stamp letter of approval from the Engineer of Record. Must comply w/ 2003 IBC & 2005 NEC. APPROVALS: REQUIRED INSPECTIONS STATUS: PERMIT NOTES: 09/30/08 Planning ok to issue builinding permit for phase I. Landscape Plans MUST be resubmitted and approved before C/O For phase II. -AT 09/30/08 CREATED FROM APPL# 08-0272 09/30/08 JS - Approved per plans and red line notes. Subject to field inspections. 09/29/08 DFB - sidewalk easements and drainage certification accompanied by signed and sealed as-builts are required prior to C/O 08/28/08 Resubmitted corrected plans for public works put in UPS's office 08/12/08 Given to DFB for review 03/10/09 10:47:27 bp701-1s City of Wheat Ridge Page 2 PERMIT INFORMATION - 081138 mmackey 08/05/08 See redline comments attached. Sent to JS for review. -AT 07/25/08 Given to AT for review INSPECTION INFORMATION: # TYPE COMM# CALLED CNCL WHO REQ DT INS DT STATUS 1 pug :Plumbing Underground 09/30/08 no cci 10/01/08 10/01/08 PARTIAL 2 eug :Electrical Undergrd. 02-2481 10/03/08 no my 10/03/08 10/03/08 COMPLETE 3 ERI :Electrical Rough Ins 02-2481 10/10/08 no KC 10/13/08 10/13/08 INCOMPLETE 4 PRI :Plumbing Rough Insp. 02-0522 10/10/08 no KC 10/13/08 10/13/08 COMPLETE 5 FRI :Framin, Rough insp. 08-0173 10/10/08 no KC 10/13/08 10/13/08 INCOMPLETE 6 fri :Framing Rough Insp. 10/22/08 no kc 10/21/08 10/21/08 PARTIAL 7 MRI :Mechanical Rough Ins 01-9993 10/30/08 no CCI 10/31/08 10/31/08 COMPLETE 8 ERI :Electrical Rough Ins 02-2481 10/30/08 no CCI 10/31/08 10/31/08 INCOMPLETE 9 ERI :Electrical Rough Ins 02-2481 11/04/08 no CCI 11/05/08 11/05/08 PARTIAL 10 PRI :Plumbing Rough Insp. 02-0522 11/05/08 no cci 11/06/08 11/06/08 COMPLETE 11 FRI :Framing Rough loop. 08-0173 11/05/08 no cci 11106108 11/06/08 INCOMPLETE 12 FRA :Framing Inspection 08-0173 11/06/08 no KC 11/07/08 11/07/08 COMPLETE 13 temp:TEMP 02-2481 11/12/08 no cci 11/13/08 11/13/08 INCOMPLETE 14 INS :Insuldtion 08-0173 11/12/08 n0 CCI 11/13/08 11/13/08 COMPLETE 15 DWS :Drywall screw/nail 08-0173 11/14/08 no cci 11/18/08 11/18/08 COMPLETE -16- EFI- :-Electr1Cdl-Final-••In, 02-2481 01/15/09 --no MV---- 01/16/09""- "01/i6/09 --COMPLETE 17 MFI :Mechanicdl Final 01-9993: 01/15/09 no KC 01/16/09 01116109 COMPLETE 18 PFI: Plumbing Final Insp 02-0522 01/15/09. no KC 01/16/09 01116109 COMPLETE 19 MLS: Mesh/lath/stucco 02-2481 02/19/09 no KC 02/20/09 02/20/09 COMPLETE 20 LFI: Landscaping Final 03/04/09 yes AT 03/05/09 03/05/09 21 BFI: Building Final loop 03/04/09 no KC 03/06/09 03/06/09 INCOMPLETE 22 bfL Building. Final Insp..--. 03/09/09..- no kc__.. 03/09/09._ .03/09/09 - ..-.COMPLETE 6 INS ''A ;:OCCUP80CVITVpe INSPECTION LANE X303)`234-5933 Inspections will not b~madd unless this cacd;isposted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings/Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic. Weatherproof / French Drain Sewer Service Lines Water Service Lines CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ROUGHS Sheathing Lath /Wall tie Mid-Roof. - Electrical Service - - Rough Electric f - Rough Plumbing c Gas Piping Rough Mechanical fp 3r rjs,3 i`712 Framing l i$ oS' TZL ti Insulation -Z Drywall Screw ~3! FINALS Electrical Plumbing /G oci' Mechanical Roof Building Final. Fire Department / ' - - , lei R.O.W & Drainage Parking & Landscaping START ALL ROUTING ONE WEEK PRIOR TO FINAL INSPECTIONS. **NOTE: ALL ITEMS MUST SE COMPLETED AND APPROVED BYPLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFOREA CERTIFICATE OF OCCUPANCY ISISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. VCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER CERTIFICATE OF COMPLETION City of Wheat Ridge 7500 W 29th Ave Wheat Ridge CO 80033 Permit# 090102 Issued: 03/09/09 Stipulations: Remodel SE Nurses Station This certificate verifies that the building constructed and/ or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. Site Address: 3835 HARLAN ST Parcel Number: 39-243-00-039 Owner: Sandalwood Manor 3835 Harlan St Wheat Ridge CO 80033 Contractor: Spectrum General Contractors 5135 E 38th Ave Denver, CO 80207 For the Following Pu Editions C/po 3 ICC/2005 NEC 0 _ 2003 ICC/2002 NEC 1997 UBC/2002 NEC S?TVkler Srtr m rpose: Commercial Remodel NO change shall be made in the USE of this building without prior notice and a new Certificate of Completion from the City of Wheat Ridge. nspector Zoning Administrator CERTI•F'ICATE MUST BE POSTED BY FRONT DOOR OF COMMERCIAL OCCUPANCIES 03/09/09 10:11 :09 City of Wheat Ridge bp701-1s PERMIT INFORMATION - 090102 PERMIT INFORMATION: Permit#: 090102 Address : 3835 HARLAN ST Permit Type: Commercial Remodel Parcel Cd : 39-243-00-039 Permit Dt: 02/13/2009 OWNER : Expires: 08/12/2009 Address : 3835 Harlan St City/St/Zip : Wheat Ridge CO 80033 LAND PARCEL INFORMATION: Zone Cd: Unassigned DO : 1 SetBacks-Front: 0.0 Pence Use: Unassigned Last Zone Dt : Left: 0.0 Subdivision: Unassigned Annex Dt : Right: 0.0 Cent Type: Miscellaneous Lot : Block No: 0 Back: 0.0 Legal: JOB DESCRIPTION: Remodel BE Nurses station- new walls, else, plumb, cabinets FEES OTT DUE PAID: Permit Fee 5,000.00 144.90 144.70 Plan Review Fee .00 94.06 94.06 Total Valuation 5,000.00 .00 .00 Use Tax 5,000.00 90.00 90.00 328.76 328.76 CONTACTS: owner Sandalwood Manor 3835 Harlan St Wheat Ridge CO 80033 , go CL1 Spectrum General Contractors 5135 E 38th Ave Denver, CO 80207 3033298003 sub CLA Picucci Electric, Inc. John A. Picucci 2827 W. 9th Ave. Denver, CO 80204 3036287576 sub CL8 Plumbing by George George Hosetz 11901 W 82nd Avenue Arvada, CO 80005 3037172281 PARCEL INFORMATION: 10 Structure Type 504 20 Year Built 1962 30 Property Type COMMR PERMIT CONDITIONS: KC: Approved per plans and notes on plans. Subject to field inspection. Must comply with 2005 NEC and 2003 IBC. APPROVALS: REQUIRED INSPECTIONS STATUS: PERMIT NOTES: 02/13/09 Given to KC for review 02/13/09 KC: Approved per plans and notes on plans. INSPECTION INFORMATION: # TYPE CONTR# CALLED CNCL WHO REQ DT INS.DT STATUS 1 ERI:Electrical Rough Ins 02-2481 02/13/09 no MV 02/17/09 02/17/09 COMPLETE 2 PRI:Plumbing Rough Insp. 02-0522 02/13/09 no KC 02/17/09 02/17/09 COMPLETE 3 fri:Framing Rough Insp. 02/17/09 no kc 02/17/09 02/17/09 COMPLETE 4 DWS:Drywall screw/nail 08-0173 02/18/09 no MV 02/19/09 02/19/09 COMPLETE 5 efi:Electrical Final Ins 02-2481 03/03/09 no cci 03/04/09 03/04/09 COMPLETE 6 pfi:Plumbing Final Insp 02-0522 03/03/09 no cci 03/04/09 03/04/09 COMPLETE 7 BFI:BUilding Final Loop 06-0173 03/05/09 no KC 03/06/09 03/06/09 COMPLETE Page mmackey F INSPECTION RECORD 'OccDpar,cylTVUe 4- INSPECTION LINE: (303) 234-5933 Inspections will not be made unless this card is posted on the building site ` Call by 3:00 PM to receive inspection the following business day. (r INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB> FOUNDATION INSPECTIONS DATE INSPECTOR .COMMENTS:'. 1 rINITIALS Footings/Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines Plumbing (Underground) !Heating (Underground) <Do NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED "framing jy Insulation W Drywall Screw , 7i t) g ♦ i CITY OF WHEAT RIDGE Building Inspection Division 00 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Al:~VW .9L06; Job Address: 3FFe, Permit Number: &1122 ,410 2iy,--3 ❑ No one available for inspection: Time !W? AM/ PM Re-Inspection required: Yes *When corrections have been made, call for re-inspection at 303-234-5933 Date: ~la~a9 Inspector DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Far INSPECTION NOTICE Inspection Type: le~rve/ 9,'01. Job Address: 3S'3S .tVWZ4 ,11 57'- Permit Number: remit? ❑ No one available for inspection: Time S~ `3S AM/PM Re-Inspection required: <fgD No "When corrections have been made, call for re-Inspection at 303-234-5933 Date: Inspector: f? DO NOT REMOVE THIS NOTICE ♦~~4' CITY OF WHEAT RIDGE Y-10000 Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: A'r IC Job Address/Permit Number: 39,? ~ivl, r 9 , f t Y, qFq'` f" n_ No one available for inspection: Time /PM Re Inspection required: Yes 60? When corrections have been made, call for re-inspection at 303-234-5933 Date: 3-q) Inspector: J' DO NOT REMOVE THIS NOTICE 71- .►~41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 fax INSPECTION NOTICE Inspection Type P/ "Y'V,e J Job Address/Permit Number: 3n?iii,P„ S1 /E6~tt k ❑ No one available for inspection: TimeM/ M 4= Re-Inspection required: Yes ¢No/ " When corrections have been made, call for re-inspection at 303-2345933 ` Date: 3'fiV Inspector: a DO NOT REMOVE THIS NOTICE e INSPECTION NOTICE Inspection Type: ur r9 Job Address: Permit Number: 6:2 -1/0 Z 11 No one available for inspection: Time O~ ANOP(~ Re-Inspection required: Yes No *When corrections have been made, call for re-Inspection at 303-234-5933 € Date: ` G Inspector: 4,e_ DO NOT REMOVE T IS NOTI~ C ♦ ! i CITY OF WHEAT RIDGE Building Inspection Division 2345933 Inspection (303) (303) 235-2855 - Office • (303) 235-2857 line Fax `It CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: P l/p • Job Address/Permit Number: r' r R rl~P?~ ~A! kf"rT f6ok""T( hfr1 rtt%r~ j t~i 110 r}h I'IPiNF 1,i Pi -P( -U .r ~Li lr6~ ~ r lit~l ll iA~!~V tP f, p; . r` ❑ No one available for inspection: Time f' J AM M Re-Inspection required: Yes Flo When corrections have been made, call for re-inspection at 303-234-5933 i Date: 3-7-rd Inspector: (I a ndv DO NOT REMOVE THIS NOTICE Y ` , 14 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line I (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: M'!'l/i+lm,'i d C'm Job Address/Permit Number: Myle l Full it5~~ti t"rEl No one available for inspection: Time / A Re-Inspection required: es No When corrections have been made, call yr-inspection 3032345933 Date: 5 k Inspect~al DO NOT REMOVE THIS NOTICE T; ♦ A i CITY OF WHEAT RIDGE ~-r Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type:===%r~r~~cor~~%1sC Job Address: 3 S'~r A $ Permit Number: P 5 0 ❑ No one available for inspection: Time 12 ~ AM/PM Re-Inspection required: Yes No ' When corrections have been made, calf for re-inspection at 303-2345933 Date: Inspector: DO NOT REMOVE THIS N¢T CE A 4' City of Wheat Ridge 1~9r Commercial Demolitio PERMIT - 090166 PERMIT NO: 090166 ISSUED:r 03./04/2009 JOB;. ADDRESS:: 3835... HARLAN ST:. EXPIRES: 08./31/2009 DESCRIPTION: Demolition of front entry ***/CONTACTS GC 303/329-8003 08-0173 Spectrum General Contractors Sub f. 303/287-2664 Francis Hillen 017924 William D. Hillen, a Corp..- PARCEL INFO ZONE CODE: UA ..;USE: UA SUBDIVISION: UA :.'BLOCK/LOT#: 0/. **FEE SUMMARY ESTIMATED 'PROJECT VALUATION: 2,250.00 FEES Permit Fee 50.00- Cd.. Total Valuation .00 M-te, 11TOTAL 50.00 Z_ I hereby certify. that. the setback distances proposed by, this permit :application. are accurate, and do not violate applicable ordinances,. rules or regulations. ofthe City of Wheat Ridge or covenants, easements or restrictions of record;.. that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all. conditions. printed on this applicat10 and that I assume fell r spon bility for compliance with. the Wheat Ridge Building Code (I.B.C) and all other applicabl `W~he_at. Ridgefrdmances, fe or / under this permit. Plans subject to field inspection. Signa~(,,e of contra or/owner 'date ` L. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the -State of Colorado and to the Zoning Regulations and Building Codes of wheat Ridge, Colorado or any. other applicable ordinances of the City:` This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension maybe granted at the discretion: of the Building Official. i. If this permit expires, :.a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans. and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment, exceeds one (1) year, full fees shall be. paid for a: new permit. No.. work of any manner shall be done that will change the natural flow of water causing a drainage; problem. Contractor shall notify. the Building Inspector twenty-four (24). hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval ofdrawings and specifications shall not be construed to be a permit for, nor anapproval of, any violation o :the provisions of the building codes or any'. other ordinance, law;: rule or regulation. All plan review is sub` ct o: 'ld mspect;,ons. signature of Chief Build !.Of cial :.date CNSPECTION REQUE LINE: (303)234-5933 :BUILDING OFFICE: (303)235-2855 ZEQUESTS MUST BE MADE BY 3PM ANY`. BUSINESS DAY FOR INSPECTION THE GFOLLOWING BUSINESS DAY. a City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Inspection Line: 303-234-5933 Date: "3 Plan Permit ® W6 ~ Building Permit Application Property Address:.) Property Owner (please print): Phone: A Mailing Address: (if different than property address) Address: State, r, Contractor: Contractor License Phone: ?(7~7--_3 GC Sub Contractors: kA-'JVevv Tnc . L_ rC,,, Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): f 7 vkej 11,t f- Construction Value: $ Z7 Description of work: (as calculated per the Building Valuation Data sheet) eY\ C 'C. g\~ tl~y Plan Review (due at time of submittal): $ Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) PRINT NAME: SIGNATURE: Date: DEPARTMENT USE ONLY ZONING COMMENTS: - Zoning. Reviewer: PUBLIC WORKS COMMENTS: Reviewer BUILDING DEPARTMENT COMMENTS OCCUPANCY: Reviewer FIRE DEPARTMENT. ❑ approved w/ comments ❑ disapproved ❑ no review required Bldg Valuation: $ Colorado Department of Public Health and Environment Air Pollution Control Division - Indoor Environment Program - Asbestos/IAQ Air Unit 4300 Cherry Creek Drive South, APCD-IE-B1 Denver, Colorado 80246-1530 Phone: 303-692-3100- Fax: 303-782-0278 E-mail: asbestos@state.co.us DEMOL This approval notice is gn No. 8, Part B, adopted De Pollution Prevention and 1 that the structure was insp and Ozone-Depleting Refi Colorado Department of F As a contractor, you may be sul requirements of the county and Department of Public Health ar that you check with county and building/permitting requirement 21,2007, and Air Quality Control active January 30, 2C d Act C.R.S.; (25-7-101 and 25-7-501 et for asbestos, luminous exit signs (conta its and the demolition contractor has pr( Health and Environment pursuant to Re jectto other demolition licenses and pea nunicipality`in which the work is being Commission Regulation 08 and the Colorado Air seq). This notice signifies ning radioactive material), >perly notified the gulation No. 8, Part B. municipal authorities in order to determine s that must be met. epending on the :led. The Colorado strongly suggests other local Please note that certain asbestos-containing materials (ACM) may remain in the structure during demolition. Therefore, any demolition debris left behind after the completion of post- demolition site cleanup may constitute a "reason to know of asbestos-contaminated soil" at the site, subject to the requirements of Section 5.5 of the Solid Waste Regulations (6 CCR 1007-2, Part 1). THE ORIGINAL APPROVAL NOTICE MUST BE POSTED ON SITE AT ALL TIMES. Immediately notify theAsbestos/IAQ Unit ofproject modifications by fax (number above) or e-mail (address above) and the appropriate county health department by fax. Project modifications include changes in the scope of work or the scheduled work dates, etc. This demolition approval notice is valid beginning 3/6/2009. The actual scheduled work dates are from 3/6/2009 through 4/6/2009. Approval issued on: 2/23/2009 Record number: 66181 Fee Paid: $55.00 Notice Number: 09DE0461D Check number: 34774 For the location specified below: Sandalwood Manor 3835 Harlan St. Wheat Ridge Denver County This notice has been issued to: Hillen Corporation 7600 Dahlia Commerce City, CO 80022 Asbestos Building Inspector: Chris Maron Cerification No.: 615 Inspection Date: 02/18/2009 Issued by: LBM VAL NOTICE t ♦ A i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 7d6,t2_L1 Jr~ rL r_ _ Job Address: 5,C 44,r 5,Y,- Permit Number: I/ lop i ` ❑ No one available for inspection: ijr Re-Inspection required: Yes //14q *When corrections have been madA~daI for Date: Inspector: AN 6 AM/PM at 303-234-5933 ♦ i CITY OF WHEAT RIDGE Bung Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: r r Job Address: ~6 rL~r cJ Permit Number: 4zs2 /42 Z- ❑ No one available for inspection: ~)me AM/PM Re-Inspection required: Yes Noll,"' / "When corrections have been made,kc6lljfor re-inspection at 303-234-5933 Date: Inspector: y City of Wheat Ridge Commercial Remodel PERMIT - 090102 x PERMIT NO: 090102 ISSUED:- 02/13/2009 JOB. ADDRESS: 3835 HARLAN ST EXPIRES: 08/12/2009 DESCRIPTION: Remodel SE Nurses station- newwalls;: elec, plumb, cabinets ti - k CONTACTS x owner Sandalwood Manor gc 303/329-8003 08-0173 Spectrum- General Contractors sub 303/628-7576 John A.Picuccl. 02-2481 Picucci.Electrl.c, Inc. sub 303/717-2281 GeorgeHOSetz 02-0522 Plumbing by George a **..PARCEL INFO y ZONE. CODEc UA. -USE: UA SUBDIVISION:' UA BLOCK/LOT#: 0/ as :a FEE SUMMARY ESTIMATED PROJECT VALUATION: 5,000.00 FEES Permit Fee' 144.70 Plan Review Fee 94.06 Total Valuation .00 Use Tax - 90.00 `**TOTAL .328.76 'a Conditions; KC: Approved perplans and notes on plans. Subject to field inspection.' Must - comply with . 2005.. NEC.. and2003 IBC. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules.. or regulations of the City.. of. Wheat Ridge or covenants,.. easements :.or. restrictions of record;.. that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application 41nd that I ass e full respon ' ility for compliance'. with the. Wheat Ridges Building Code (I.B.C). and all other k _ at Ridge or antes,. for r under this permit. Plans subject to field inspection. applicable w Sign t e of. contractor/owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the - State of Colorado..and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable 1 ordinances of the city. 2.. This permit. shall expire.. 180. days from the issue date. Requests for an extension must be received prior. to expiration c date... An extension may. be. granted at the discretion of the Building Official. s r 3. If this permit expires, a new permit may be acquired for afee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any. suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid.. fora new permit 4. No. work of any manner shall be done that will. change. the natural flow of. water causing adrainage problem. 5. Contractor shall notify the Building inspector twenty-four (24) hours in advance for all inspections and :shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be apermit for, nor. an approval of, any violation of the provisions. of the. building.. codes or any:. other: ordinance, law, rule or regulation. .;,4 All plan review is sub' ctf field inspections. ' din fficial date Signature of Chief Bu INSPECTION REQ ST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. x OF WHEgpR/ City of Wheat Ridge Building Division m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855' Fax: 303-235-2857 o Inspection Line: 303-234-5933 O<ORPD Building Permit Application / < Property Address: ~f{ ~j JInr.I~r.n kAAO-. rt, Property Owner (please print): Mailing Address: (if different than property address) Date: a~ Plan l Permit #:C-q~/&7P Cj Phone: UCR-399 Address: /60 City, State, Zip: st• l 4. h0-cr r to TOZ06 Contractor: Contractor License 0$ - d L 13 Sub Contractors: oz ~2H$ t. Electrical City License Company: ' tc,ucc k Stec. Exp. Date: Phone: 36::1 - Plumbing City License 0'Z-65'Z'Z- Mechanical City License Company 4?~WWb~1 67 G-rdle Company: Exp. Date: Exp. Date: Use of space (description): to CS p>V\ Construction Value: $ 'i -©0- Description of work: AS Wl watas C0JD,1&tt$ tt p (as calculated per the Buiidiluafion Data sheet) wu y A-OQS 461, n,,rr-S st-,It& Plan Review (due at time of submittal): $ -1, y Sq. Ft./L.Ft added: 0 Squares BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCEONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESE ATIVE of(QWNE^R) (C NTRATOR) PRINT NAME: `4-"~e ~b LSS e- SIGNATURE: Date: 2 O DEPARTMENT USE ONLY ZONING COMMENTS: Zoning. Reviewer: PUBLIC WORKS COMMENTS: Reviewer. BUILDING DEPARTMENT COMMENTS ll e>,J1 OCCUPANCY:~°/ Reviewer FIRE DEPARTMENT': El approved w/ comments 11 disapproved ❑ no review required Bldg Valuation: $ ou ea ~ - S eS ST~T1 t~~t. ~ ~ KEYNOTES (THIS SHEET ONLYI ~ . - NEW WALL CABINETS CI;' . -,w NEW 2'-0° D. PL3 COUNTERTOP @ 30' A.F.F.; BRACING AS NEC. EXISTING DOORWAY AND WINDOW OPENING TO REMAIN ARTWORK NICHE. W/ 3/4` S3 CTR. TOPA 9122 SULANOSE EDGE; BOTTOM OF NICHE @ A.F.F. TO r-0" A.F.F. ACCENT PA114T AT BACK OF NICHE T.B.D. ADD FR PLYWOOD TO REINFORCE WA! LS AS NEC. FOR CHA@ STING STAR. PRC 'DED. E.0., FLOOR TO CEILING REWORK EXISTING SINBOPLUMBING & PROVIDE NEW LOW HT. PARTIT/ON 9 V-6" A.F.F W/PAINT iD VWOOD'CAP. NEW PL3 COUNTER @ 36" A.F.F.; REPLACE EXISTING SINK ANOL FAUCET W1 A1a7 APS. HARDWOOD FRAME FOR NEW 4V X V-9" OPENING; PAINT FRAMETO MATCH TRIM @ EXIST. BLDG END EXIST. HANDRAIL OR CHAIRRAIL NEW ACROVYN CRASH RAIL #M-270 ENTIRE WALL, MOUNT BOTTOM OF!RAIL@ 13-0"*F.F..'COLOR: 303 1 CARAMEL PROVIDE AND INSTALL NEW CLEAR CORNER GUARD AT ALL CORRIDOR OUTSIDE CORNERS THIS AREA; GUARD TO BE ACROVYN "LG" SERIES (AVAIL. IN VARIOUS ANGLES AS NEM), 4 IM- LEG. CONTINUE CROWN MOULDING AROUND NEW PARTITION AT CORRIDOR SIDE TO MATCH EXISTING. 2003 IBC, IMC, IPC, IPMC, IECC, IFC, IFGC; 2005 NEC; NFPA 99 and ICC/ANSI A117.1 - 2003 EC: FOR NEW NURSE' S7 NEW AS SHOWN IF NEC. IV_ I 9 HT. TO REMAIN, PATCH AND REPAIR AS NEC., PAINT P6 MED.RM. EXISTING LIGHTING TO i i EXISTING CEILING HT TO I REMAIN, PATCH AND REPAIR AS NEC., PAINT P6 j EXISTING LIGHTING TO REMAIN r-9^ S. NURSE EXISTING CEILING HT. TO STATION REMAIN, PATCH AND REPAIR AS NEC., PAINT P6 i LS 'L9 NOTE: SWITCH ALL NEW LIGHTING WIEXISTING; NEW LOCATION REFLECTED CEILING PLAN SCALEE*IM" = ILV HEADER @ &-8" .F.; PAINT P6 K, j \ r v S! 4 LB INTERIORS Project Name: Sandalwood Manor sheatFwffanm nla I I~ A ' ts~aere~mKa: teaemlamN=bem9820.00 omm 4 Feb. 2009 t)tavnnB ! IX-02 Number .J f _ r MED.RM, f, j 74- ~NJ CP ~e S. NURSE ~~PT-3 STATION SV _ i CPT5 NOTE: PT-1 AT ALL WALLS U.N.A. FINISH PLAN SCALEIW= 9' V 4 LBA INTERIORS Proeet Nwe: Sandalwood Manny sneatR~o eaea:.Na Se` LEAPM tmWNuNumber: 48 R 2 sWgmemal IX' 03 l L Data: eb. 009 Number 1 FURNITURE PLAN ,h $CAMV = VW " ` LBA INTERIC3RS Prp ect Name: Sandalwood Manor S" Rataraw nla wnmaa~n.m~row ' Issuendenga~: LBAPCPdNanCac 9820:00 suppro" 1 ~X 04 ~ _ Data: 4 Feb: 2009 - N umbee: r o E 2'-8" Q S O , C (O N E P c f? V 3. N B A 4"33 TOP W11 2"SULLNOSE FRONT DOE; EXTEND EDGE AST OUTSIDE ERTICAL CORNER 4" EA. SIDE PAINT ACK OF "NICHE" WENT COLOR, a4aos~ !b t t7 9 -.2®P~3 ELEVATION SCALE114" =1'-0" LBA IN'fERIOF2S ProjectName. Sandalwood Manor rrwmaxn<mmm - r69JB.n8rBf@flpS _ l IBAProjectfdrtnber., 9326.00 D l fitpplhnentel I/\-O6 u d l we l 4 Feb: 200® F umtier . ~fif:P.?/ f CITY OF WHEAT RIDGE ' Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office r (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: O~rc ?rJ2f~lirr t~ Job Address/Permit Number: 3~33t1~p~Az~ st • ps'/ifa' ~t/ !JW 3/ Tsai r,'~✓^r~ ?;:ZL~ y F i~ S-f~?7ioa.~ .LS 6Fr~fAa!rs*~/drFV rr~ ~s~Err~is°` }~t>rZ. r ❑ No one available for inspection: Time r9: rro AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: J Inspector: r I DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type:-7/1 - Job Address/Permit Number: ~~3~ 24s7 ;77 1 ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes , When corrections have been mad ~ e; call for re-' spection at 303-234-5933 Date: / zL D~ Inspector: II,, I DO NOT REMOV FcIS NOTICE - ~ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 3,,/955' .!<alAA%l usriOf~~rl~~ Job Address/Permit Number: Ax • 0&'13Sg ~~u/ s>ains~/.C~sr.~•F/i7 SFv~ft' .1i,vf ~-~GSt-,' C% S.€, a'l~ns? of fX s amd/ s~'l~v~. 3?FQ©v7f:~ ~u ra s~fsc~ SfusFf2 ~isuF orlf Gri /r~Ird . ❑ No one available for inspection: Time lllcS AM/PM Re-Inspection required: Yes When corrections have been made, call for re-inspection at 303-234-5933 vx Date: 114loF Inspector: DO NOT REMOVE THIS NOTICE. CITY OF WHEAT RIDGE _ Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax I ~Il! ~ INSPECTION NOTICE. Inspection Type:? c 8 Job Address/Permit Number: ❑ No one available for inspectio/n:(~Tlne Re-Inspection required: Yes NO'S *When corrections have been mad , ca 1 /or re-'f spection A Date: Inspector: i E DO NOT REMOVE IS NOTICE AM/PM at 303-234-5933 ♦~~4' ~ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE j n j'i Inspection Type: ~~,,.,.aA F;i~<,t€' Job Address/Permit Number: 35Nf%rtif f~Et? ❑ No one available for inspection: Time fj/ YAM )PM Re-Inspection required: Yes o J `When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: r v DO NOT REMOVE THIS NOTICE I "4' City of Wheat Ridge Commercial Addition PERMIT 081358 PERMIT NO: 081358 - ISSUED: 11/19/2008 JOB ADDRESS: 3835 HARLAN ST EXPIRES: 05/18/2009 DESCRIPTION: Phase II - Rehabilitation facility CONTACTS owner 303/399-2040 - Sandalwood Partnership gc 303/329-8003 08-0173 Spectrum General Contractors PARCEL INFO ZONE CODE: C-1 USE: C-1 SUBDIVISION: UA BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 2311,918.73 FEES Permit Fee 13,525.95 2 Plan Review Fee 8,600.44 Plan Review Addtiona 8,791.87 Total Valuation .00 Use Tax 41,614.54 TOTAL 72,532.80 Conditions: All work shall comply with applicables codes, notes and stipulations All work is subject to field inspection and Fire Dept. approval Approval by Building, Planning, Fire, Public Works and Jeffco Health required prior to issuance of C.O. or occupancy I' hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that. all measurements hewn, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application d Chat I sume full r sponsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable heat Ridge 4dinmces, /Jr work under this permit. Pons subject to field inspection. 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. I. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject t?) field inspections. Signature of Chief Buil icial date. INSPECTION REQU- T LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST B MADE BY 3PMANY BUSINESS DAY. FOR INSPECTION THE FOLLOWING BUSINESS DAY • OF WFIEAT~i City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855' Fax: 303-235-2857 Inspection Line: 303-234-5933 OOLORPOO Building Permit Application Property Address: ~ 35 ~fhywNn Jpylreet Property Owner (please print): Mailing Address: (if different than property address) Address: -1W J Contractor: Contractor Sub Contrac rs: Electrical City LI e Company: ~IClSCG Exp. Date: Phone: ('Jo pr--fit=94A t1sC-~D --161ooktJG rl uo wuar. Cot Company: pany UYt~~~tl~ C~QC~ge Exp. Date: Exp. Date: Use of space (description): NuIZSIN V ttOM~ Construction Value: e-$e QQ~~~ (as calculated per the Buildin Valuatio Data '7 4escription of work: submittaQ:$ ioh~ac'Ai-~y (~j6fT Plan Review /due at time of Sq. Ft./L.Ft added: 3 I Squares 1o BTU's Gallons Amps tse ~fitlS . o 84 • b nFm1~ OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applica le Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: ( WNER) (CONTRACTOR) or CERSONA~REF PRINT NAME: c lOCNh kA"4erGD(N SIGNATURE: Date: I DEPARTMENT USE Y ZONING COMMENTS KAT4 amoet X 1vAA\ (fit VO,r~/Ep.S ~ 01 V • +"I I • is ~IS• f i~J~ zoning, t A/c- Cd ~i IV/ //1 Revlewe . Y PUBLIC WORKS COMMENTS: Reviewer «~rJ ~EY~ /rJ~t/l,2SVli v~s~-2~TS OCCUPANCY:- BUILDING DEPARTMENT CO ENTS: Rewewer. in/a5~~ 9 FIRE DEPARTMENT:: [I approved wl comments ❑ disapproved ❑ no review required Bldg Valuation: $ ~P 7Da: 2~ 6-qv i erm0 O , 11/19/08 09:46:19 City of Wheat Ridge Page 1 bp340-iq ESTIMATE OF VALUATIONS AND FEES jschumacher THE FOLLOWING INFORMATION ARE ESTIMATES ONLY AND NOT ACTUAL VALUES. CODE-- DESCRIPTION--- -----VALUATION -----FEE ---USE TAX prm Permit Fee 2,686,870 .86 15, 307.20 0. 00 rvw Plan Review F 2,686,870 .86 9, 949.68 0. 00 totva Total Valuati 2,686,870 .86 0.00 0. 00 use Use Tax 2,686,870 .86 0.00 48,363. 68 TOTAL VALUATION: 2686,870 .86 FEES VALUATION: 2686,870 .86 PERMIT FEE: 15,307 .20 USE TAX: 48,363 .68 OTHER FEES: 9,949 .68 TOTAL FEES: 73,620 .56 i2voZ 9 ~V L? & City of Wheat Tidge COMMUNITY DEVELOPMENT Memorandum TO: John Shumacher, Dave Brossman FROM: Adam Tietz DATE: September 9, 2008 SUBJECT: Sandalwood building permit Plan# 08-0302 Just wanted to give you each your copies of the plans for phase 2 of the Sandalwood Manor building permit. I have been reviewing it but didn't them to get held up with my review while you could be reviewing it. When you are done reviewing the plans, make your notes in ADG then give them back to me. I will compile the notes and redlines and give them back to Melissa. City of Wheat Ridge Building Permit Submittal List The following items are required for the single- or two family building permit submittal for the property located at . If any of the required items are not included in the submittal, the submittal will be considered incomplete and returned immediately without review. This sheet must be submitted with the building permit application. Please initial beside each required item, signifying that it has been included. Review Required by: O Building ❑ Planning ❑ Public Works SUBMITTAL DOCUMENTS: Plans: ❑ Three (3) full-sized (24"x 36") plans (Contents of plans detailed in the Single- and two-family handout) - yellow heading ❑ Three (3) stamped sets of foundation plans. ❑ Three (3) copies of a grading and erosion control plan. ❑ One (1) copy of a soils report. DOCUMENTATION: ❑ One (1) completed building permit application. ❑ One (1) property deed. ❑ One (1) certified survey or improvement Location Certificate. ❑ Proof of utility availability (form provided by city). ❑ One (1) building permit submittal list. Tih~ following items are required for the commercial or multi-family building permit submittal for the property located at 3351 If any of the required items are not included in the submittal, the submittal will be considered incomplete and returned immediately wi hout review. If you had a pre-application meeting with Staff, you must submit the checklist you received. Otherwise, this sheet must be submitted with the building permit application. Please initial beside each required item, signifying that it has been included. Review Required by: ❑ Building ❑ Planning ❑ Public Works SUBMITTAL DOCUMENTS: Plans: )(Four (4) full-sized (24" x 36") plans (Contents of plans detailed in the Commercial & Multi-family handout) -pink heading ~.f ❑ Two (2) copies of a final drainage report and plan (S Hb JN t Q p t^Q V 1 Ovlc ii (yy P~)GtSQ J ~P OR ~J Two (2) copies of a drainage letter and plan 55 ❑ Two (2) copies of a grading and erosion control plan (S ynlp yyvl BQ D rev k o v.Gt N F~A c\$Q' ❑ Two (2) copies of a traffic impact study I J OR Two (2) copies of a trip generation study ~ glnYj w•l ~d "b •,r-Q,kJ lOlh~j~ 111 NAG e DOCUMENTATION: One (1) completed building/ permit application. \ ❑ One (1) property deed. \ s~blW Q d prev i CSVM/',l4 ~iAl7~ ❑One(1) certified survey or Improvement Location Certificate. 1 SvJln MVW64 ~Y-01 1~'1~ 1h' 1 °d ❑ Proof of utility availability (forth provided by city). 4 1 ln_ XOne(1) building permit submittal list. City of Wheat Ridge Building Permit Submittal List The following items are required for the single- or two family building permit submittal for the property located at . If any of the required items are not included in the submittal, the submittal will be considered incomplete and returned immediately without review. This sheet must be submitted with the building permit application. Please initial beside each required item, signifying that it has been included. Review Required by: 0 Building 0 Planning 0 Public Works SUBMITTAL DOCUMENTS: Plans: 0 Three (3) full-sized (24"x 36") plans (Contents of plans detailed in the Single- and two-family handout) - yellow heading 0 Three (3) stamped sets of foundation plans. 0 Three (3) copies of a grading and erosion control plan. 0 One (1) copy of a soils report. DOCUMENTATION: 0 One (1) completed building permit application. 0 One (1) property deed. 0 One (1) certified survey or Improvement Location Certificate. 0 Proof of utility availability (form provided by city). 0 One (1) building permit submittal list. r Tfh~ ,fol'lo`wing items are required for the commercial or multi-farnily building permit submittal for the property located at 337I+~,,,,.~ CC+.,33.. - If any of the required items are not included in the submittal, the submittal will be considered incomplete and returned immedi~atelout review. If you had a pre-application meeting with Staff, you must submit the checklist you received. Otherwise, this sheet must be submitted with the building permit application. Please initial beside each required item, signifying that it has been induced. Review Required by: 0 Building 0 Planning 0 Public Works SUBMITTAL DOCUMENTS: Plans: )(Four (4) full-sized (24" z 36") plans (Contents of plans detailed in the Commercial & Multi-family handout) - pink heading 0 Two (2) copies of a final drainage report and plan S Hbt/N 1 e, ~J rev 10"1 A 4 Gtse ~J OR J Two (2) copies of a drainage letter and plan 1I 0Two(2) copies ofa grading and erosion control plan (s~6o'kt ea p P~Qt/tOlhralU th k1cASe 0 Two (2) copies of a traffic impact study JJ OR Two (2) copies of a trip generation study C U"~ rV'*A DOCUMENTATION: ~y-Q~v tOIACa~',r '~h.A.$ 2 J One (1) completed building permit application. 0 One (1) property deed. C SLA6w _k ~e d rrev i Ov\sIN 1h ~ $ f LI One (1) certified survey or Improvement Location Certificate. pre v 1 O"Ga Ua • ` 0 Proof of utility availability (form provided by city). XOne (1) building permit submittal list. OF W HEgT~ City of Wheat Ridge Pre-Application Transmittal Sheet COtoRP, 0 Date: October 19, 2007 Now that the required pre-application meeting has been held, the next step in the process will be: ® Submit land use application ® Submit building permit ❑ Schedule a neighborhood meeting (a neighborhood meeting must be held prior to submittal) The following documents are required upon submittal: Pre-application transmittal sheet Land use application Building permit application Full set of civil drawings Outline Development Plan Final Development Plan Final Plat Site Plan Survey/I.L.C. Other: ® Property deed ® Letter of request ❑ Property owner consent ® Drainage report ® Traffic impact letter ❑ Traffic study ® Soils report ® Grading/erosion control plan ® Electronic copy of Plat (In AutoCAD format) All of the listed items must be submitted to constitute a complete application. If any of the items are not included in the submittal, the application will be returned without review. City of Wheat Ridge Community Development Department 7500 W. 29th Avenue Wheat Ridge, CO 80033 Building Division - 303.235.2855 Planning Division - 303.235.2846 Inspection line - 303.234.5933 www.ci.wheatridoe.co.us City of Wheat Ridge Pre-Application Transmittal Sheet Date: October 19, 2007 Now that the required pre-application meeting has been held, the next step in the process will be: ® Submit land use application ® Submit building permit ❑ Schedule a neighborhood meeting (a neighborhood meeting must be held prior to submittal) The following documents are required upon submittal: ® Pre-application transmittal sheet ® Land use application ® Building permit application ❑ Full set of civil drawings ❑ Outline Development Plan ❑ Final Development Plan ❑ Final Plat ® Site Plan ® Survey/I.L.C. ® Property deed ® Letter of request ❑ Property owner consent ® Drainage report ® Traffic impact letter ❑ Traffic study ® Soils report ® Grading/erosion control plan ® Electronic copy of Plat (In AutoCAD format) ❑ Other: All of the listed items must be submitted to constitute a complete application. If any of the items are not included in the submittal, the application will be returned without review. City of Wheat Ridge Community Development Department 7500 W. 29th Avenue Wheat Ridge, CO 80033 Building Division - 303.235.2855 Planning Division - 303.235.2846 Inspection line - 303.234.5933 www.ci.wheatridoe.co.us COMcheck Software Version 3.4.0 Envelope Compliance Certificate 2003 IECC Report Date: 08/13108 Data filename: S:\Drawings\2008\Sandalwood Manor 08045\Belfay\Calculations\COMcheck\Copy of Sandalwood Comcheck.cck Section 1: Project Information Project Title: Sandalwood Manor Construction Site: Owner/Agent: Designer/Contractor: 3835 Harlan Street David Bellefeuille Wheat Ridge, CO Belfay Engineering 2811 W. 9th Ave. Denver. CO 80204 Section 2: General Information Building Location (for weather data): Denver, Colorado Climate Zone: 13b Heating Degree Days (base 65 degrees F): 6020 Cooling Degree Days (base 65 degrees F): 679 Project Type: New Construction Vertical Glazing / Wall Area Pct.: 19% Building Type Other Section 3: Requirements Checklist Climate-Specific Requirements: Component Name/Description Floor 1: Slab-On-Grade:Unheated Comments: Therapy/Therapt Office, 22A-pm Floor 2: Slab-On-Grade:Unheated Comments: Conference Room, 22A-pm Floor 3: Slab-On-Grade: Unheated Comments: Office Space, 22A-pm Floor 4: Slab-On-Grade:Unheated Comments: Dining, 22A-pm Floor 5: Slab-On-Grade:Unheated Comments: Serving, 22A-pm Floor 6: Slab-On-Grade:Unheated Comments: Lounge, 22A-pm Floor 7: Slab-On-Grade:Unheated Comments: Hall, 22A-pm Floor 8: Slab-On-Grade:Unheated Comments: Entrance/Reception, 22A-pm Floor 9: Slab-On-Grade: Unheated Comments: Family Gathering, 22A-pm Floor 10: Slab-On-Grade:Unheated Comments: Main Corridor, 22A-pm Floor 11: Slab-On-Grade:Unheated Comments: Individual Room - SE Single Bed, 22A-pm bunamg coaes or other oromances of the coy snap not be vi Gross Area Cavity Cont. Proposed Budget or Perimeter R-Value R-Value U-Factor U-Factor 81 0.0 34 0.0 32 0.0 66 0.0 9 0.0 - 8 0.0 1 0.0 106 0.0 - 18 0.0 7 0.0 18 0.0 Wheat Ridge B ilding Department OVed Floor Area p 16165 BUIL NG OFFICIAL A7 Validity of permit: The issuance of a permit or approval of plans, specifications and computations shall not be a permit for, or an approval of, any violation to Sandalwood Manor Page 1 of 7 Floor 12: Slab-On-Grade:Unheated 51 0.0 - Comments: Individual Room- 2bed, 22A-pm Ceiling 1: All-Wood Joist/Rafter/Truss 1180 30.0 0.0 0.035 0.057 Comments: TherapyTrherapt Office, 18C-30 Ceiling 2: All-Woad Joist/Rafteflfruss 245 30.0 0.0 0.035 0.057 Comments: Conference Room, 18C-30 Ceiling 3: All-Wood Joist/Rafter/Truss 589 30.0 0.0 0.035 0.057 Comments: Office Space, 18C-30 Ceiling 4: All-Wood Joist/Rafter/Truss 765 30.0 0.0 0.035 0.057 Comments: Dining, 18C-30 Ceiling 5: All-Wood Joist/Rafter/Truss 138 30.0 0.0 0.035 0.057 Comments: Serving, 18C-30 Ceiling 6: All-Wood Joist[Rafter/Truss 846 30.0 0.0 0.035 0.057 Comments: Lounge, 18C-30 Ceiling 7: All-Wood Joist/Rafter/Truss 525 30.0 0.0 0.035 0.057 Comments: Hall, 18C-30 Ceiling 8: All-Wood Joist/Rafter/Truss 1020 30.0 0.0 0.035 0.057 Comments: Entrance/Reception, 18C-30 Ceiling 9: All-Wood Joist/Rafter/Truss 224 30.0 0.0 0.035 0.057 Comments: Family Gathering, 1 BC-30 Ceiling 10: All-Wood Joist/Rafter/Truss 1765 30.0 0.0 0.035 0.057 Comments: Main Corridor, 18C-30 Ceiling 11: All-Wood Joist/Rafter(rruss 245 30.0 0.0 0.035 0.057 Comments: Individual Room - SE Single Bed, 18C-30 Ceiling 12: All-Wood Joist/Rafter/Truss 338 30.0 0.0 0.035 0.057 Comments: Individual Room- 2bed, 18C-30 Wall 1: Wood Frame, 16" o.c. 495 19.0 0.0 0.068 0.087 Comments: Thempy/Therapt Office, 12E-Osw Window 1: Vinyl Fmme:Double Pane, Clear, SHGC 0.56 120 - 0.570 0.586 Comments: Therapy/Therapt Office, 1 D-cv-o Wall 2: Wood Frame, 16" o.c. 315 19.0 0.0 0.068 0.087 Comments: Therapy/Therapt Office, 12E-0sw Window 2: Vinyl Frame:Double Pane, Clear, SHGC 0.56 20 0.570 0.586 Comments: Therapy/Therapt Office, 1 D-cv-o Wall 3: Wood Frame, 16" o.c. 135 19.0 0.0 0.068 0.087 Comments: Conference Room, 12E-Osw Window 3: Vinyl Frame:Double Pane, Clear, SHGG 0.56 23 - 0.570 0.586 Comments: Conference Room, 1 D-cv-o Wall 4: Wood Frame, 16" o.c. 205 19.0 0.0 0.068 0.087 Comments: Conference Room, 12E-Osw Window 4: Vinyl Frame:Double Pane, Clear, SHGC 0.56 24 0.570 0.586 Comments: Conference Room, 1 D-cv-o Wall 5: Wood Frame, 16" o.c. 320 19.0 0.0 0.068 0.087 Comments: Office Space, 12E-Osw Window 5: Vinyl Frame:Double Pane, Clear, SHGC 0.56 60 0.570 0.586 Comments: Office Space, 1 D-cv-o Wall 6: Wood Frame, 16" o.c. 520 19.0 0.0 0.068 0.087 Comments: Dining, 12E-Osw Window 6: Vinyl Frame:Double Pane, Clear, SHGC 0.56 137 0.570 0.586 Comments: Dining, 1D-cv-o Wall 7: Wood Frame, 16" o.c. 70 19.0 0.0 0.068 0.087 Comments: Dining, 12E-Osw Window 7: Vinyl Frame:Double Pane, Clear, SHGC 0.56 16 0.570 0.586 Comments: Dining, 1D-cv-o Wall 8: Woad Frame, 16" o.c. 70 19.0 0.0 0.068 0.087 Comments: Dining, 12E-Osw Window 8: Vinyl Frame:Double Pane, Clear, SHGC 0.56 16 - - 0.570 0.586 Comments: Dining, 1D-cv-o Wall 9: Steel Frame, 16" o.c. 90 19.0 0.0 0.114 0.087 Comments: Serving, 12E-0bm Window 9: Vinyl Frame:Double Pane, Clear, SHGC 0.56 16 0.570 0.586 Comments: Serving, 1D-cv-o Wall 10: Wood Frame, 16" o.c. 35 19.0 0.0 0.068 0.087 Comments: Lounge, 12E-Osw Window 10: Vinyl Frame:Double Pane, Clear, SHGC 0.56 14 0.570 0.586 Comments: Lounge, 1D-cv-o Sandalwood Manor Page 2 of 7 Door 1: Glass 21 0.650 0.138 Comments: Lounge, 1D-cb-d Wall 11: Wood Frame, 16" o.c. 45 19.0 0.0 0.068 0.087 Comments: Lounge, 12E-Osw Wall 12: Wood Frame, 16" o.c. 353 19.0 0.0 0.068 0.087 Comments: Entrance/Reception, 12E-Osw Window 11: Vinyl Frame:Double Pane, Clear, SHGC 0.56 84 0.570 0.586 Comments: Entrance/Reception, 1D-cv-o Wall 13: Wood Frame, 16" o.c. 407 19.0 0.0 0.068 0.087 Comments: Entrance/Reception, 12E-Osw Window 12: Vinyl Frarr uble Pane, Clear, SHGC 0.56 84 0.570 0.586 Comments: Entrance/Reception, 1D-cv-o Door 2: Glass 42 0.650 0.138 Comments: Entrance/Reception, 1D-cb-d Wall 14: Wood Frame, 16" o.c. 300 19.0 0.0 0.068 0.087 Comments: Entrance/Reception, 12E-Osw Window 13: Vinyl Frame:Double Pane, Clear, SHGC 0.56 48 0.570 0.586 Comments: Entrance/Reception, 1 D-cv-o Wall 15: Wood Frame, 16" o.c. 45 19.0 0.0 0.068 0.087 Comments: Family Gathering, 12E-Osw Wall 16: Wood Frame, 16" o.c. 135 19.0 0.0 0.068 0.087 Comments: Family Gathering, 12E-Osw Window 14: Vinyl Frame:Double Pane, Clear, SHGC 0.56 20 0.570 0.586 Comments: Family Gathering, 1 D-cv-o Wall 17: Wood Frame, 16" o.c. 70 19.0 0.0 0.068 0.087 Comments: Main Corridor, 12E-Osw Window 15: Vinyl Frame:Double Pane, Clear, SHGC 0.56 16 - 0.570 0.586 Comments: Main Corridor, 1 D-cv-o Wall 18: Wood Frame, 16" o.c. 135 19.0 0.0 0.068 0.087 Comments: Individual Room - SE Single Bed, 12E-Osw Window 16: Vinyl Frame:Double Pane, Clear, SHGC 0.56 24 0.570 0.586 Comments: Individual Room - SE Single Bed, 1 D-cv-o Wall 19: Wood Frame, 16" o.c. 46 19.0 0.0 0.068 0.087 Comments: Individual Room - SE Single Bed, 12E-Osw Wall 20: Wood Frame, 16" o.c. 175 19.0 0.0 0.068 0.087 Comments: Individual Room- 2bed, 12E-Osw Window 17: Metal Frame with Thermal Break:Double Pane, Clear, 40 - 0.570 0.586 SHGC 0.56 Comments: Individual Room-2bed, 1D-cb-o Wall 21: Wood Frame, 16" o.c. 330 19.0 0.0 0.068 0.087 Comments: Individual Room- 2bed, 12E-0sw Window 18: Vinyl Frame:Double Pane, Clear, SHGC 0.56 24 0.570 0.586 Comments: Individual Room-2bed, 1D-cv-o Window 19: Vinyl Frame:Double Pane, Clear, SHGC 0.56 10 0.570 0.586 Comments: Individual Room-2bed, 1D-cv-O Door 3: Solid 21 0.320 0.138 Comments: Individual Room-2bed, 11C (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: ❑ 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor-permeable wrapping material installed in accordance with the manufacturer's installation instructions. ❑ 2. Windows, doors, and skylights certified as meeting leakage requirements. ❑ 3. Component R-values & U-factors labeled as certified. Fi 4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. ❑ 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. n 6. Cargo doors and loading dock doors are weather sealed. F-1 7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air-tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. F1 8. Building entrance doors have a vestibule and equipped with closing devices. Exceptions: Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq. ft. in area. Sandalwood Manor Page 3 of 7 ❑ 9. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement., The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck Version 3.4.0 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Sandalwood Manor Page 4 of 7 COMcheck Software Version 3.4.0 ~(l Mechanical Compliance Certificate 2003 IECC Report Date: 08/13108 Data filename: S:\Dmwings\2008\Sandalwood Manor 08045\Belfay\Calculations\COMcheck\Copy of Sandalwood Comcheck.cck Section 1: Project Information Project Title: Sandalwood Manor Construction Site: Owner/Agent: Designer/Contractor: 3835 Harlan Street David Bellefeuille Wheat Ridge, CO Belfay Engineering 2811 W. 9th Ave. Denver, CO 80204 303-892-5980 belfay@belfay.com Section 2: General Information Building Location (for weather data): Denver, Colorado Climate Zone: 13b Heating Degree Days (base 65 degrees F): 6020 Cooling Degree Days (base 65 degrees F): 679 Project Type: New Construction Section 3: Mechanical Systems List Quart! System Type & Description 1 F-1: Heating: Duct Furnace, Gas / Cooling: Split System, Capacity >=90 - <135 kBtu/h, Air-Cooled Condenser / Single Zone 22 PTAC-1: Heating: Unit Heater, Gas / Cooling: Split System, Capacity <65 kBtu/h, Air-Cooled Condenser 1 MUA-1: Heating: Central Furnace, Electric / Cooling: Other, Capacity >=135 - <240 kBtu/h, Evaporatively Cooled Condenser / Single Zone 1 RTU-1: Heating: Central Furnace, Gas / Cooling: Rooftop Package Unit, Capacity >=90 - <135 kBtu/h, Air-Cooled Condenser / Single Zone 1 RTU-2: Heating: Central Furnace, Gas / Cooling: Rooftop Package Unit, Capacity >=135 - <240 kBtu/h, Air-Cooled Condenser/ Single Zone 1 RTU-3: Heating: Central Furnace, Gas / Cooling: Rooftop Package Unit, Capacity >=90 - <135 kBtu/h, Air-Cooled Condenser/ Single Zone 1 RTU-4: Heating: Central Furnace, Gas / Cooling: Rooftop Package Unit, Capacity >=135 - <240 kBtu/h, Air-Cooled Condenser / Single Zone 6 BB-1: Heating: Unit Heater, Electric Section 4: Requirements Checklist Requirements Specific To: F-1 : F-1 1. Equipment minimum efficiency: Duct Furnace (Gas): 80% Ec F1 2. Equipment minimum efficiency: Split System: 10.1 EER Requirements Specific To: PTAC-1 : ❑ 1. Equipment minimum efficiency: Unit Heater (Gas): 80% Ec ❑ 2. Equipment minimum efficiency: Split System: 10.0 SEER Requirements Specific To: MUA-1 : Sandalwood Manor Page 5 of 7 1. Integrated air economizer required - Exception: Air/evap condenser serving space with open-case refrigeration Requirements Specific To: RTU-1 : O 1. Newly purchased heating equipment meets the heating efficiency requirements ❑ 2. Equipment minimum efficiency: Rooftop Package Unit: 10.1 EER Requirements Specific To: RTU-2 : 1. Newly purchased heating equipment meets the heating efficiency requirements ❑ 2. Equipment minimum efficiency: Rooftop Package Unit: 9.5 EER ❑ 3. Integrated air economizer required Requirements Specific To: RTU-3 : ❑ 1. Newly purchased heating equipment meets the heating efficiency requirements F-I 2. Equipment minimum efficiency: Rooftop Package Unit: 10.1 EER Requirements Specific To: RTU-4 : 1. Newly purchased heating equipment meets the heating efficiency requirements ❑ 2. Equipment minimum efficiency: Rooftop Package Unit: 9.5 EER ❑ 3. Integrated air economizer required Requirements Specific To: BB-1 None Generic Requirements: Must be met by all systems to which the requirement is applicable: Fi 1. Load calculations per 2001 ASHRAE Fundamentals O 2. Plant equipment and system capacity no greater than needed to meet loads - Exception: Standby equipment automatically off when primary system is operating - Exception: Multiple units controlled to sequence operation as a function of load ❑ 3. Minimum one temperature control device per system ❑ 4. Minimum one humidity control device per installed humidification/dehumidification system ❑ 5. Thermostatic controls has 5 degrees F deadband - Exception: Thermostats requiring manual changeover between heating and cooling ❑ 6. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2-hour occupant override, 10-hour backup - Exception: Continuously operating zones - Exception: 2 kW demand or less, submit calculations ❑ 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow, >3,000 cfm Fi 8. Outside-air source for ventilation; system capable of reducing OSA to required minimum ❑ 9. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly - Exception: Ducts located within equipment - Exception: Ducts with interior and exterior temperature difference not exceeding 15 degrees F. ❑ 10. Ducts sealed -longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181 B tapes and mastics - Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification ❑ 11.Mechaniral fasteners and sealants used to connect ducts and air distribution equipment ❑ 12. Hot water pipe insulation: 1 in. for pipes <=1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerant/brine pipe insulation: 1 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes -1.5 in. and 3 in. for pipes >1.5 in. - Exception: Piping within HVAC equipment - Exception: Fluid temperatures between 55 and 105 degrees F - Exception: Fluid not heated or cooled - Exception: Runouts <4 ft in length O 13. Operation and maintenance manual provided to building owner ❑ 14. Balancing devices provided in accordance with IMC 603.15 ❑ 15. Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Sandalwood Manor Page 6 of 7 Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2003 IECC requirements in COMcheck Version 3.4.0 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Sandalwood Manor Page 7 of 7 BELFRY ENGINEERING Mechanical & Electrical Consulting Engineers * 2811 West 9" Ave. TEL: (303) 892-5980 Denver, CO 80204 FAX: (303) 892-5979 email: belfay@belfay.com ~ WHEgT qi August 13, 2008 C COR City of Wheat Ridge Wheat Ridge Building Department Building Inspection Division pproved 7500 W. 29` Ave. Wheat Ridge, CO 80033 2e 1~k B LD G OFFICIAL ATE PROJECT: Sandalwood Manor - Validity of permit: The issuance of a permit or approval of plans, specifications PROJECT ADDRESS: 3835 Harlan Street and computations shall not be a permit for, or an approval of, any violation to BELFAY JOB 08045 any of the provisions of the building code or of any City ordinances. DBDLOG#: - Permits presuming to give authority to violate or cancel the provisions of the Building codes or other ordinances of the City shall not be valid. We are requesting an administrative modification to allow ASHRAE 62.1-2004 table 6-1 Minimum Ventilation Rates in Breathing Zone for outdoor air ventilation requirements in lieu of IMC 2003 table 403.3 Required Outdoor Ventilation Air for this project. Thank you for your review of this item. If you have any questions or concerns, please do not hesitate to contact me. Sincerely lfstin Salerno CITY OF WHEAT RIDGE Building Inspection Division z Z ° (303)'234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE owl o Inspection Type: j 1,5ex 1Q_ S r c~ Job Address/Permit Number: 3 3~~ ~Gn ❑ No one available for inspection: Time AM/PM Re-Inspection required: "Yes No `When corrections have been made, call for re-inspection at 303-234-5933 Dated / g /fix Inspector: DO NOT REMOVE THIS NOTICE `1I4' ~ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: `-r sr i c-, c --f` ;i7 Job Address/Permit Number: t f~ 1 / 4' CITY OF WHEAT RIDGE Building Inspection Division r ,(303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE OFsI (3~ Inspection Type: :Zj.~r:s Job Address/Permit Number: SS7s G 7_ ❑ No one available for inspection: Time AM/PM k Re-Inspection required: '4es_- No k ` I, When corrections have been made, call for re-inspection at 303-234-5933 Inspector•~~ ~l Dater f { DO NOT REMOVE THIS NOTICE VII ❑ No one available for inspection: Time AM/PM Re-Inspection required: "Yes When corrections have been made, call for re-inspection at 303-23 -5933 Date: / Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE / Building Inspection Division 1v X303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax i' i INSPECTION NOTICE Inspection Type: tiw~ C . r Job Address/Permit Number: CITY OF WHEAT RIDGE Building Inspection Division `(303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE 0e5 3 Inspection Type: i c Job Address/Permit Number: 72 ~Al (cr ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes o When corrections have been made, call for re-inspection at 03-234-5933 Date:/ Inspector: -mow DO NOT REMOVE THIS NOTICE ❑ No one available for inspection: Time AM/PM Re-Inspection required: Ye No When corrections have been made, call for re-inspection 303-234-5933 Date: )t!6 Inspector: 4 / DO NOT REMOVE THIS NOTICE ~ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE 0 5' 1(3 Inspection Type: e ~ec, CA V0 i ~ Job Address/Permit Number: w zs f~ -1 «p ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes `When corrections have been made, call for re-inspection at 303-234-5933 Date:jr Inspector DO NOT REMOVE THIS NOTICE r'n =;~--{7 ir.. r ~~.~.r, ~ P F CITY OF WHEAT RIDGE A Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: c n ( Job Address/Permit Number: 41 CITY OF WHEAT RIDGE / Building Inspection Division (303) 234-5933 Inspection line ~~JJ (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: '?rs~ Tom/ o . , Job Address/Permit Number: s 2 <L~ /~_o, ,a .aY; . o` ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes 19 When corrections have been made, call for re-inspection at 303-234-5933. # Date: / Inspector:, DO NOT REMOVE THIS NOTICE r ❑ No one available for inspection: Time AM/PM Re-Inspection required: es No When corrections have been made, call for re-inspection at 303-234-5933 Date: /r Inspector: i DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE r Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax. INSPECTION NOTICE Inspection Type: &_r' ;ac G9uC,~ Job Address/Permit Number: ❑ No one available for inspection: Time AM/PM Re-Inspection required: I:f No When corrections have been made, call for re-inspection at 303-234-5933 Date dr / Inspector: DO NOT REMOVE TH/ NOTICE ♦~~41 V, CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line _:J (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: /W 7_44L, Job Address/Permit Number: 3835 •ffo,~! s~sr- o~~e3T a1-0 &Ii.vDO.y r(d,FjarF e4,7- -f- 120612 Gw CG S °oK ❑ No one available for inspection: Time /a: ys AM/PM Re-Inspection required: Yes No When corrections have been made, call_foorr re-inspection at 303-234-5933 T~. Date: Inspector: DO NOT REMOVE THIS NOTICE 4' CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: AIW. d Job Address/Permit Number: .7335.E r<57-. O8©b°s✓ ❑ No one available for inspection: Time io,, vo AM/PM Re-Inspection required: Yes When corrections have been made, call for re-inspection at 303-234-5933 Date: a AI J Inspector' DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 064 gfL 4 Xm2w tS Job Address/Permit Number: ~~~lL,L , cj . txaJ/3d ❑ No one available for inspection: Time : a AM/PM. Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date:!- Inspector: _ DO NOT REMOVE THIS NOTICE 1 I , CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: - 3 Job Address/Permit Number: ijLh~n~ c~-~TL ❑ No one available for inspectiotme AM/PM Re-Inspection required: Yes / N9 'When corrections have been ma /e /call jr re-inspection at 303-234-5933 Date: Mjjja~ i Inspecto ' DO NOT REMOVE S NOTICE -77777777-77 7777 CITY WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: (,U a Job Address/Permit Number: g ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes loj When corrections have been made, call for re-Inspection at 303-234-5933 Date: l~ Inspector: DO NOT REMOVE THIS NOTICE ♦~~I CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ' (303) 235-2857 Fax INSPECTION NOTICE /c9~.v~o:~d +c Inspection Type: Job Address/Permit Number: ~~`Sf~oL~~ ~BG 7Q ~f~/1 }z / - ~~tf!', 7t rLrr'~ -&1/Z ❑ No one available for inspection: Time,/>%~S AM/PM Re-Inspection required: Yes No When correctiio'nns have been made, call for re-inspection at 303-234-5933 Date: 7 ec0, Inspector: r DO NOT REMOVE THIS NOTICE " , City of Wheat Ridge 1r9r Commercial Addition PERMIT - 081138 PERMIT NO: 081138 ISSUED: .09/30/2008 JOB ADDRESS: 3835 HARLAN ST EXPIRES: 03/29/2009 DESCRIPTION: Rehabilitation facility addition @ nursing home CONTACTS owner 303/399-2040. Sandalwood Partnership go 303/329-8003 08- 0173 Spectrum General Contractors sub 303/628-7576 John A. Picucci 02- 2481 Picucci Electric, Inc. sub 303/717-2281 George Hosetz 02- 0522 Plumbing by George sub 303/296-2999 Harold Rogers 01- 9993 Rogers & Sons Inc. PARCEL INFO ZONE CODE: C-1 USE: C-1 SUBDIVISION: UA BLOCK/ LOT#: 0/ **FEE SUMMARY ESTIMATED PROJECT VALUATION: 895,623.62 FEES Permit Fee 6,651.23 Plan Review Fee 3,736.82 Plan Review Addtiona 586.48 Total Valuation .00 Use Tax 16,121.23 CIS TOTAL '77 27,095.76 Conditions: All foundations must be inspected and verified to the building division by wet stamp letter of approval from the Engineer of Record. Must comply w/ 2003 IBC & 2005 NEC. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this applicatio nd that I assume.full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicableat Ridge Ard2nances/7or work under this permit. Plans subject to field. inspection. Signature of. contractor/owners mace 1. This permit was issued in accordance with the provisions set forth in your. application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violati of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is ct field inspections. Signature of Chief B din Off icial date INSPECTION. REQ EST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. of w" T City of Wheat Ridge Building Division Date: b 7 -~Ci' 0g i ° 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Plan o Inspection Line: 303-234-5933 Permit #:0 ~LORP~ i Building Permit Application Property Address: or reej Property Owner (please print): Mailing Address: (if different than property address) L Address: t6c, - l Sf enoA c~-1Y eet eeLL City, State, Zip: ~,rt\f~/v C U10r(,tdC~ U01?-OG Contractor: Z)',C.~ Yr V% C Yl bsi! 1!L-~ ON[ rfAc- l 0r,~n t r\c- Contractor License I I ~t Phone: Sub Contractors: -rd 3t- be-TC-HAIN&D •-~bibDit4G Electrical City License Plumbing City License Mechanical City License Company: I~iCQX~C ale ~c Company P UMbf,\OJ ~ Company: R6q-t Ir s d C~ Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): A(&(Vj1Yt MQ Construction value: Description ofwork: i 16 t\ (,t (as calculated per the Building Valuati nData sheet) l~l'.,,l~Ut`a\t®101 [,t `tv` Y1G``°~L"'~10~ Plan Review (due at time ofsubmittal):$ Sq. Ft./L.Ft added: Squares y BTU's Gallons Amps * dr City of Wheat~dge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 291h Ave. August 5, 2008 Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 Spectrum General Contractors RE: Phase I Building Permit Sandalwood Manor 3835 Harlan St. Wheat Ridge, CO 80033 To Whom It May Concern: The building permit application for phase one of the building expansion and improvements to Sandalwood Manor at the address above has been received. After the first review of documents, I have the following comments: Landscape Plan Cover Page 1. The site calculations table needs to updated and should include the following: • Total Site Area: existing and proposed • Total Building Square Footage and Percent of Lot Coverage: existing and proposed • Parking Area and Number of Spaces: existing and proposed. • Total Landscaped Area: existing and proposed 2. The total landscaped area calculation should include a break down of the existing and proposed items listed below. • Living material area (turf, plants and trees) • Non living material landscape materials (mulch, gravel, landscaping blocks, pavers) 3. Landscaped areas in the city owned right-of way cannot be calculated into the site landscape calculations. Page L1.0 1. City code states commercially zoned land is required to have 1 street tree is required for every 30 feet of frontage the property has along a street. • According to survey submitted with this plan, the W. 38d' Ave. frontage is 221 feet long which would require 7 street trees. The plans indicate that there 6 trees along W. 38b Ave. An additional tree will need to be added to the plans. • The Harlan Street frontage has length of 284 feet which requires 9 street trees. The plans indicate only 6 trees along Harlan St. with one being removed (just north of the driveway). If this tree is removed 4 additional trees will need to be added to the Harlan St. frontage. Should this tree remain, only 3 additional trees will be required. The locations of the remaining trees will need to be indicated on the plan. 2. One landscaped island is required for every 30 parking spaces. The landscaped islands must be the size of one full parking space and is required to have a minimum of four shrubs and one tree. wwwxi.wheatridgexo. us • Only one landscaped island is required for this development since there are 53 spaces. The two smaller landscape islands located in the parking lot do meet the size requirement. Combined they are equivalent to one parking spot. The islands however do not meet the landscaping requirement as there are no trees indicated in any of the islands in or surrounding the parking lot. A tree must be added to at least one of these islands to satisfy the landscaping requirement. 3. When a parking lot of a commercially zoned property is adjacent to a property zoned for residential use the parking lot must be screened by a wall, view obscuring fence, or hedge. • The 6 foot tall, wood fence along the north property line must be extended to the landscaped island beyond the last parking space in the northeast corner of the parking lot. • All fencing will require a separate permit. 4. Please indicate the ground cover materials to be use in all locations marked with the red dots. Include these areas in all landscape breakdowns and calculations. 5. The plans show the existing sign at the corner of W replaced with a new sign. 38`h Ave. and Harlan St. will be removed and Please be advised a separate permit for all signage will have to be obtained in order to begin work on any sign construction or installation. All signs regulations can be found in Chapter 26, Article 7 of the City of Wheat Ridge Code of Laws. Page U.2 1. Please provide a landscape area breakdown for the courtyard. The breakdown should include the following: • Living landscape square footage and the coverage percentage in relation to the entire site. • Non-living landscape square footage and the coverage percentage in relation to the entire site. • Hard surface square footage and the coverage percentage in relation to the entire site. 2. Please indicate the ground cover materials to be use in all locations marked with the red dots. Include these areas in all landscape breakdowns and calculations. Building Design Page A-3 I The architectural treatments given to the new entry on the north end of the building, or something similar, should continue beyond entry and extend to the south onto the existing building in order to tie the existing building in with the new north entry and phase II of the project together. Please make the above corrections to the plans and re-submit them for final approval. More information may also be required to be provided by other departments depending on their comments pertaining to this permit Feel free to contact me with any questions or concerns at 303.235.2845. Sin A am ,Tie Planner, Community Development Department City of Wheat Ridge, Colorado p. 303.235.2845 atietz@ci.wheatridge.co.us City of Wheatldge COMMUNITY DEVELOPMENT Building Inspection Division Plan Review Notes 1 st Review 9/28/08 Sandalwood Partnership 1667 St. Paul Street Denver, CO 80206 Project Address: 3835 Harlan Street, Wheat Ridge, CO 80033 A review of your submittal documents for City of Wheat Ridge Plan #08-0272 for an addition at 3835 Harlan Street, Wheat Ridge, CO, 80033 was conducted and the following notes, corrections and clarifications are hereby attached to and indicated on the submitted plans: 1. All work shall comply with: 2003 International Building Code 2003 International Plumbing Code 2003 International Mechanical Code 2003 International Fuel Gas Code 2003 International Energy Conservation Code 2005 National Electrical Code 2003 ANSI Al 17.1 City of Wheat Ridge Municipal Code 2. Page A-3: All asphalt shingles shall be nailed with a minimum of six nails per shingle. Ice and water shield underlayment extending a minimum of two feet inside the exterior wall line is required. Mid-Roof inspection is required. 3. Page S-1: All inspections related to foundation systems shall be conducted by the engineer-of- record and verified to the Building Division prior to or at the time of the first rough framing inspection. The requested items from the Planning Division must be re-submitted and approved prior to permit issuance. Upon satisfaction of the attached planning comments, permit is ready for issuance. Cordially, Ohn chumacher, Jr., CBO Chi B 'lding Official City o Wheat Ridge Building Department 7500 W. 29"` Avenue Wheat Ridge, CO 80033 Office (303) 235-2853 Fax (303) 235-2857 City of Wheat 'ge _iC COMMUNITY DEVELOPMENT Building Inspection Division Plan Review Notes Ist Review 9/28/08 Sandalwood Partnership 1667 St. Paul Street Denver, CO 80206 Project Address: 3835 Harlan Street, Wheat Ridge, CO 80033 A review of your submittal documents for City of Wheat Ridge Plan 908-0272 for an addition at 3835 Harlan Street, Wheat Ridge, CO, 80033 was conducted and the following notes, corrections and clarifications are hereby attached to and indicated on the submitted plans: 1. All work shall comply with: 2003 International Building Code 2003 International Plumbing Code 2003 International Mechanical Code 2003 International Fuel Gas Code 2003 International Energy Conservation Code 2005 National Electrical Code 2003 ANSI At 17.1 City of Wheat Ridge Municipal Code 2. Page A-3: All asphalt shingles shall be nailed with a minimum of six nails per shingle. Ice and water shield underlayment extending a minimum of two feet inside the exterior wall line is required. Mid-Roof inspection is required. 3. Page S-l: All inspections related to foundation systems shall be conducted by the engineer-of- record and verified to the Building Division prior to or at the time of the first rough framing inspection. The attached comments from the Planning Division must be satisfactorily addressed and approved by Planning prior to issuance of a Certificate of Occupancy. Cordially, Xoo CBO Ch' f B lding lding Official Ci Wheat Ridge Building Department 7500 W. 29th Avenue Wheat Ridge, CO 80033 Office (303) 235-2853 Fax (303) 235-2857 City of Wheat~ge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29'" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 301235.2857 Review Date: Project Address: ~f Project Description: Gen. Occ. Type: Occ. Type/Item Sq. Ft./Unit Cost per SF/Unit Total Valuation O Total Project Valuation = Review Notes: ;~=wvv.ri.wtu•atridge.eo.as $ qq~Vo sec u ° Plan Review Calculation Sheet 09/30/2008 13:22 FAX 3032352857 PLANNING 3032352846 12001/006 City of COMMERCIALIMULT I-FAMILY ~7~IheatRldge SUILDINGPERMITAPPLICATIONREVIEW l PUBLIC WOAKS Date: ~T~2R~6 Location: 3835 NAYU-4w) Sr2~~ - ATTENTION: BUILDING DEPARTMENT I have reviewed the submitted application documents to construct a Carat in~-a? c/.YL ~J inn ~+~x~ to be located at the above referenced address. Please note the summary comments below. 1. Property Boundary Closure: ✓K _ Not OK; refer to stipulations. 2. J,fef Drainage: a. Final Drainage Report and Plan required b. Drainage Plan & Certification Letter required _ C. Lot drainage/grading is to be reviewed by the Building Division _ d. Site drainage/grading has been reviewed and are: ~OK _ Not OK; refer to stipulations 3. _ z NPDES Permit Required: ✓Yes - No 4. ✓ Public Improvements to be completed: a. street paving/patching; ✓ Yes _ No b. curb & gutter/drivecut: ✓ Yes _ No c. sidewalk: Yes _ No d. standard street lights: Yes _t-No e. pedestrian lights: _ Yes ✓No f. storm sewer: Wes _ No g. Letter of Credit required: _ Yes ✓No If a Letter of Credit is required, for what improvements? P S`S Go vodc~ v yb~]2 ROZA) cm.~,>r e~ no adM4-OZ17- a oAub Amount of the letter of credit: $ ,U ri4 5. ✓ SIA/PIA required: _ Yes t/No 6. ✓ Traffic impact analysis required & approved: _ Yes :!/~No 7. Street Access Permit required: _ Yes --kef'No If yes, was it approved by the Director of Public Works? _ Yes _ No 8. ✓ Does all existing roadway/alley R.O.W. meet the standards of the City: ✓Yes No If not, what is requested: 06+ Has the dedication been received? _ Yes _ No 9. APPROVED: The Public Works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated or attached stipulations. 7 12-9 Signature David F. Brossman, P.L.S. Date 10. NOT APPROVED: The Public Works Department has reviewed the submitted material and does not approve this Permit Application for the stated or attached reason(s). Signature David F. Brossman, P.L.S. Dare 11.~ stipulations: wit ,vE~ Stb~.vut 4F rs TS Pkta,e TO C O. 12. ~ NOTE: Any damage to the existing Public Improvements as a result of this construction is to be repaired to meet City standards by the Permit Applicant prior to the issuance of the Certificate of Occupancy (C.O.). A Drainage Certification Letter accompanied by As-Built plans shall be required prior to the issuance of the Certificate of Occupancy. b14< City of arl~WheatR,Oge PUBLIC WORKS City of Wheat Ridge Municipal Building 7500 W. 29`h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATED: T4.7/68r ADDRESS: 38--is -n~ Sr~ Dear Contractor: In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as determined by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the existing condition(s) of the public improvements at this address. If you have any questions, please contact me at 303.235.2864. Sincerely, David F. Brossman, P.L.S. Development Review Engineer CC: File www.ci.wheatridge.co.us Rev 2108 09/30/2008 13:23 FAX 3032352857 PLANNING 3032352846 IM 003/006 ti' , J> City of WheatFpidge PUBLIC WORKS City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033.8001 P: 303.235.2861 F: 303.235.2857 Date: `f 3 Applicant: Phone # Location of Construction: 383' l- A&W a-.J srya ^ Purpose of Construction: ~er+¢ MC2LliP2 Q-'4_ I Single Family Commercial .X. Multi-Family Development Review Processing Fee $100.00 $ /00.00 (For document processing) Single Family Residence/Duplex Review Fee: $50.00 $ Commercial/Multi-Family Review Fees: • Review of existing technical documents: $100.00 $ • Initial review' of technical civil engineering documents (Fee includes reviews of the I~ and 2"d submittals) $500.00 $ A 00.an • Traffic Impact Study Review Fee: (Fee includes reviews of the I" and 2ad submittals): $400.00 $ • Trip Generation Study Review Fee: $200.00 $ ' Each Application will be reviewed by staff once and retumed for changes. If after review of the second submittal changes have not been made to the civil documents or the Traffic Study as requested by staff, further reviews of the Application will be subject to the following Resubmittal Fees: • Resubmittal Fees: 3'd submittal initial review fee)%................................................... $250.00 $ 4d' submittal (full initial review fee): $500.00 $ All subsequent submittals: $500.00 $ (Full initial review fee) TOTAL REVIEW FEES (due at time of Building Permit issuance): $ PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE ADDITIONAL LICENSING AND PERMITTING FEES REQUIRED FOR CONSTRUCTION OF IMPROVEMENTS WITHIN PUBLIC RIGHT-OF-WAY. Signature of Applicant Date www. d.when tri dge.coms Rev 2108 a 4/' City of Wheat~dge PUBLIC WORKS APPLICATION FOR MINOR GRADING/FILL PERMIT APPLICANTS NAME: SRc c~Jtti w w w o X CbnJCdGtr~FO r s APPLICANT'S ADDRESS: ADDRESS OF FILL: DATE OF APPLICATION: l`~3d / Q'~K All permits shall be applied for through the Public Works Department. An approved permit is effective for a period of one (1) year from date of issue and may be renewed. All fees shall be in accordance with those fees established by the Uniform Building Code or other applicable City adopted Resolutions or Ordinances. Note: All public improvements, when constructed, shall be maintained (by the respective individual(s) and/or company responsible for the construction of that public and/or private improvement in the respective development) on a daily basis, or as needed, such that they are free of mud and other construction debris tracking from the site. Failure to comply with this requirement will result in the enforcement of Article III, Specified Nuisances, Section 15-16 (4) of the City of Wheat Ridge Code of Laws. MINOR GRADING, EXCAVATION, AND FILL PERMITS 1-50 Cubic Yards: No permit is required for dumping or excavation of earth materials, which do not exceed 50 cubic yards, provided, however, that any fill deposited is on natural terrain of less than three (3) horizontal to one (1) vertical slope, or such fill is less than three (3) feet in depth and is not intended to support permanent structures, and in addition, such fill or excavation does not obstruct or otherwise adversely affect any drainageway. Should any of the above standards be exceeded, or a drainage way be affected, a permit shall be required under the guidelines for No. 2. 2. 51-500 Cubic Yards: Dumping or excavation of earth materials not exceeding 500 cubic yards may be allowed with a permit approved by the City Engineer. All applications are to be submitted on the appropriate completed application form and shall be accompanied by the appropriate fee and sketch plan indicating the following information before the permit will be issued. A. Location and dimensions of all property boundaries and structures on the site. B. Location and extent of areas to be filled and/or excavated. C. Location of existing and proposed drainageways, irrigation ditches, etc., and indication of how and where historic run-off will be maintained on and through the site. D. Cross-section area to be filled and/or excavated indicating original slope, new slope and depth of fill. E. Statement that indicates the proposed use or purpose for said fill or excavation. F. Relative elevation of adjacent properties. G. Erosion control plan showing placement of control devices such as hay bales, etc. 3. 501-10,000 Cubic Yards: Operations in which earth material fill or excavation exceeds 500 cubic yards, but does not exceed 10,000 cubic yards, may be allowed by a permit issued by the City Engineer after review of an application and supporting information. The following information shall be submitted with the required application form: A. A site plan, prepared and signed by a Colorado registered professional engineer, at a scale of no less than 1 inch to twenty feet (1:20) which illustrates the following: B. Location and dimensions of all property boundaries and structures on the site. C. Location and extent of areas to be filled and/or excavated. D. Location of existing waterways and drainage courses indicating any changes. (for a site containing an established irrigation ditch, a letter of approval from the appropriate ditch company shall be required). E. Location of existing and proposed points of ingress. F. Location and extent of existing vegetation, proposed changes in such vegetation and methods of rehabilitation on site vegetation after earthwork operations are complete. G. Erosion control plan. H. Grading plan with existing (dashed lines) and proposed (solid lines) ground contours with contour intervals of 2 feet and spot elevations. At least two cross sections (east to west and north to south) through the site showing depth of fill and/or excavation. J. A drainage report may be required if site runoff characteristics are changed. K. Relative elevations of adjacent properties and structures. L. Statement of purpose of intended fill and/or excavation. 4. Performance Standards: The following provisions shall apply to all Minor Grading, Excavation and Fill Permits: A. Rehabilitation: Within thirty (30) days after cessation of filling and/or excavation, rehabilitation for the site shall have been completed in accordance with the approved plans. Rehabilitation shall consist of leveling, grading, landscaping or any combination thereof to minimize potential erosion and be acceptable to the City Engineer. B. Debris: Debris and/or contaminants shall not be used except with the approval of the City Engineer. "For the purpose of this Section, the term debris shall have the same meaning as the terms "garbage, trash or junk" as defined in the Wheat Ridge Code of Laws, Section 15-4." In no case shall debris or contaminates identified or classified as hazardous waste by local, state or federal agencies be used as fill in any fill areas within the City of Wheat Ridge. C. Excavation and/or fill areas shall be graded to facilitate weed control until final grades are set and site rehabilitation and use occur (must be leveled with side slopes not to exceed 3 to 1). J:\FOR S & LETTERS\ APPS & PERMITSWinor Grading & Fill Peamit.doc 2 Rev 03/08 09/30/2008 13:25 FAX 3032352857 PLANNING 3032352846 IM006/006 5. Permit Fees* 50 cubic yards or less $23.50 51 to 100 cubic yards $37.00 101to 1000 cubic yards for the first 100 cy ; 60 $37.00 J/. plus for each additional 100 cy or fraction thereof cy X $17.50/100cy 1001 to 10,000 cubic yards for the first 1000 cubic yards $194.50 plus, for each additional 1000 cy or fraction thereof cy X $14.50/1Kcy Total Cubic Yards = *Wheat Ridge Code of Laws Section 5-76. TOTAL Amount= $ All permits shall be applied for prior to fill deposition or excavation operations begin. Any permit applied for after cutting or filling operations on site are in progress shall be subject to a double fee and other penalties as prescribed by Wheat Ridge Code of Laws, Section 26-1004. Any fill requested under this permit within the 100 year flood zone MUST COMPLY WITH WHEAT RIDGE CODE OF LAWS, SECTION 26-801, FLOOD PLAIN ZONING ORDINANCE. I HEREBY ACKNOWLEDGE THAT THIS APPLICATION IS CORRECT AND UNDERSTAND THAT I CANNOT START THIS PROJECT UNTIL THIS APPLICATION IS APPROVED. I SHALL COMPLY WITH THE LAWS OF THE STATE OF COLORADO AND WITH THE ZONING REGULATIONS AND BUILDING CODE OF THE CITY OF WHEAT RIDGE. ANY VIOLATION OF THE ABOVE TERMS WILL CAUSE IMMEDIATE REVOCATION OF THIS PERMIT AND COMMENCEMENT OF ENFORCEMENT PROCEEDINGS BY THE CITY OF WHEAT RIDGE. THIS APPROVED PERMIT WILL BE KEPT IN MY POSSESSION OR PERMANENTLY ON THE JOB SITE. APPLICANT: CITY OF WHEAT RIDGE: r` p 4icants Signature City Engineer Owner's Signature (if different than above) Approval Date J?FORMS g LET RS\APPS& PE1WflITSWin0rGMdb8& Pill Pv t.do 3 Rev 03108 09/30/2008 13:25 FAX 3032352857 PLANNING 3032352846 IN01 T% REPORT z~ TRANSMISSION OK T%/R% NO 0641 DESTINATION TEL # 93033298032 DESTINATION ID ST. TIME 09/30 13:22 TIME USE 03'10 PAGES SENT 6 RESULT OK A 41~ City of WheatRodge PUBLIC WORKS Date: _~~ZR~trT Property Boundary Closure: ✓K _ Not OK; refer to stipulations. Location: 3835 /4/1-24 "-°•1 57T2G'T ATTENTION: BUILDING DEPARTMENT I have reviewed the submitted application documents to construct a Ccivs r-~s1~t'L 7'r"T'~'J to be located at the above referenced address. Please note the summary comments below. 1. 2. J~ 3. 4. Drainage: a. Final Drainage Report and Plan required 4 b. Drainage Plan & Certification Letter required C. Lot drainage/grading is to be reviewed by the Building Division _ d. Site drainage/grading has been reviewed and are: _j2~'OK _ Not OK; refer to stipulations NPDES Permit Required: C O MME R C I A L /M UL TI - FA MI L Y BUILDING PERMIT APPLICATION REVIEW ✓Yes ^ No public improvements to be cam leted: a. street paving/patching: ✓ Yes _ No b. curb & gutter/drivecut: ✓ Yes _ No c. sidewalk: Yes No _ d. standard street lights: _ Yes ~-Io e, pedestrian lights: _ Yes ✓No f. storm sewer: _yfYes o g. Letter of Credit required: If a Letter of Credit is required, for what im _ Yes provements? ✓ No P ,2`s Got/mddEb tjrkvaae.. 17Zl) P=V. IT Bb&> Amount of the letter of credit: $ 5. ✓ SIA/PIArequired: - Yes Y ✓No /No 6. ✓ Traffic impact analysis required & approved: es - --L 7. J~ Street Access Permit required: - Yes Y i/No No if yes, was it approved by the Director of Public Works? es _ g, Does all existing roadway/alley R.O.W. meet the standards of the City: ✓Yes - No If not, what is requested: ti7~k Has the dedication been received? _ Yes - _ No 9. APPROVED: The public works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated or attached stipulations. City of Wheat1idge PUBLIC WORKS Memorandum TO: John Schumacher, Chief Building Official FROM: Dave Brossman, Development Review Engineer DATE: September 26, 2008 SUBJECT: Sandalwood Manor Phase I Expansion Project I have completed the second review of the Construction Plans and Final Drainage Report, received with a Building Permit Application on August 28, 2008, for the above referenced development located at 3835 Harlan Street. This Memo is to inform you that all of the above-mentioned documents for this development have been reviewed and are hereby approved for construction by the Department of Public Works. A copy of the approved Final Drainage Report will need to be provided by MB Consulting, Inc. to the construction contractor for the storm system and settling basin. The Engineer-of-Record also needs to be aware of the following items regarding the construction of the project: 1. Grading and Erosion Control The erosion control for the project shall be in place prior to the commencement of any grading activities, and maintained as needed during the course of construction. Please be advised that additional erosion control measures may be required if deemed necessary by the City Inspector. 2. NPDES/CDPS Permit The area of proposed area of disturbance for this construction project is greater than one acre and therefore requires an NPDES Permit for construction activities. The NPDES permit for construction activities is issued by the State through the Colorado Discharge Permit System (CDPS), and may be obtained by contacting the Colorado Department of Public Health & Environment, Water Quality Control Division at 303-692-3500 and asking for the public assistance person for the Permits Unit. A copy of the CDPS Permit must be submitted to the Department of Public Works prior to issuance of any Grading/Fill or Building Permits. 3. Application for Grading/Fill Permit Prior to the commencement of any onsite grading, an Application for a Minor Grading/Fill Permit, along with the fees due will need to be submitted for review and approval. 4. Public Improvement Restoration/Debris Tracldng It will be the responsibility of the of the contractor for the project to repair any damage to the existing public improvements along Kipling Street or 50,b Avenue as a result of related construction traffic in the area. Also, the contractor will be responsible for maintaining Kipling Street and 50a Avenue on a regular basis such that it remains free of construction debris and tracking from construction traffic accessing the site. 5. Right-of-Way Construction Permit(s), Licensing, and Bonding Prior to any construction within the public right-of-way, the necessary Right-of-Way Construction Permit(s) and respective licensing will need to be submitted for processing by the Public Works Engineering September 26, 2008 Page 2 City. Right-of-Way Construction Permits are issued only after approval of all required technical documents, including but not limited to, the Final Drainage Report & Plan, Final Plat, Final Development Plan, Traffic Impact Study, Storm Sewer Plans, Street Construction Plans, Grading & Erosion Control Plan, Traffic Control Plan, and easement or ROW dedications. In addition, if the cost of the proposed public improvements exceeds $10,000, additional warranty bonding shall be required. 6. 2-Year Warranty Period for Public Improvements The contractor shall warrant all work performed within the public Right-of-Way for a period of two (2) years, commencing upon completion of all constructed public improvements and Final Acceptance by the City Inspector. Prior to the expiration of said 2-year Warranty Period, if the City Inspector at any time deems that the constructed public improvements are in such condition as to require replacement or repairs, the contractor shall complete such repair work upon request per the City of Wheat Ridge Permit Testing and Inspection Requirements. Stormwater Maintenance Agreement and O & M Plan Required All post-construction Best Management Practices (BMP's) for water quality must be maintained and inspected by the property owner(s) per Section 20-34 of the City of Wheat Ridge Municipal Code of Laws. For the stormwater quality facilities including, but not limited to, above-ground or underground detention facilities, porous landscape detention areas, porous pavement, centrifuge type devices such as a Rinker Stormcepter®, or for a hydrodynamic separation system such as a Contech VortechsO, a Stormwater Maintenance Agreement accompanied by an Operations and Maintenance (O & M) Schedule/Log will be required prior to issuance of the Certificate of Occupancy. The O & M Schedule/Log must be kept current and will be inspected on a regular basis by City staff to ensure compliance with City of Wheat Ridge requirements. 8. Drainage Certification Required Prior to C.O. Upon completion of the drainage improvements, the Engineer-of-Record Mr. Travis J. Nicholson, P.E., shall provide to the City of Wheat Ridge a written, signed and sealed Drainage Certification Letter stating that the site grading was completed per the approved Grading & Erosion Control and Drainage Plans, all drainage facilities were constructed and shall function as defined in the approved Final Drainage Report/Plan, and that the site has been accurately surveyed to confirm that the grading and the construction of all drainage facilities was completed in accordance with these documents. The Drainage Certification Letter shall be submitted to the City for review and approval, and shall be accompanied with As-Built Plans for all constructed drainage facilities prior to issuance of a Certificate of Occupancy (or Certificate of Completion). Two (2) copies of the "As-Built" Plans shall be submitted as follows: a. 1 copy is to be on full-size 24" X 36 "bond paper, signed and sealed, and b. 1 copy is to be on electronic media (DVD or CD-ROM) and shall be in AutoCAD 2000- 2007 Awg format only. 9. Materials Testing for Construction within the Public Right-of-Way It will be the responsibility of the developer/owner, to provide the necessary testing, as applicable for the scope of this project, for sub-grade compaction and other related material tests for any improvements to be constructed within the public Right-of-Way. (SEE ATTACHED MATERIAL SAMPLING & TESTING REQUIREMENTS) CC: Steve Nguyen, Engineering Manager Meredith Reckert, Senior Planner File Sandalwood Phase I Expansion Building Permit App - approval.k.doe Public Works Engineering September 26, 2008 Page 3 CITY OF WHEAT RIDGE MATERIALS AND TESTING REQUIREMENTS FOR CONSTRUCTION OF PUBLIC IMPROVEMENTS DESCRIPTION Materials sampling and testing for public improvements shall be performed by an independent materials testing company at the expense of the developer, and/or utility district. Unless otherwise designated, all referenced specifications, standards or policies shall be the latest edition as revised or updated by approved supplements published and issued prior to the date of the building permit. REQUIREMENTS All materials sampling and testing shall be performed by certified, experienced and qualified materials testing technicians who work under the supervision of a registered professional engineer in the State of Colorado. All materials sampling and testing equipment shall be serviceable and have current calibrated certifications. Soil classifications and moisture-density curves shall be provided to the Department of Public Works inspector prior to in-place density testing. Materials testing technicians shall furnish copies of failed test results to the inspector as promptly as the results become available. On a weekly basis when testing is being performed, the developer shall furnish the inspector with copies of all test results taken during the prior week and a cover letter, signed by the supervising registered professional engineer, which summarizes the results and discusses any failed tests or inconsistencies. The City materials testing requirements are provided in Table 720-1. All testing procedures of verification and central lab requirements shall be as specified in the Frequency Guide Schedule of the Colorado Department of Transportation Field Materials Manual. One test is required for any fraction of the specified frequency. The reference to Section 203.07 in the table is from the Colorado Department of Transportation Standard Specifications for Road and Bridge Construction. Sandalwood Phase I Expansion Building Permit App - approval.ltr.doc Public Works Engineering September 26, 2008 Page 4 Table 720-1 City of Wheat Ridge Materials Testing Requirements Type of Test Frequency Remarks Soil Survey (Classification), 1 per 500 feet of roadway, Surveys for roadway and trench AASHTO M145 Sidewalk or pipe trench may be combined Moisture-Density Curve, 1 per on-site soil type AASHTO method determined AASHTO T99 1 per import material source By soil or materials type Embankment in-place density, I per 250 feet per lane per 6-inch Minimum density per soil Colorado Procedures loose lift classification, Section 203.07 Roadway subgrade in-place 1 per 250 feet per lane Minimum density per soil density, Colorado Procedures Classification, Section 203.07 Sidewalk subgrade in-place 1 per 250 feet of sidewalk Minimum density per soil density, Colorado Procedures Classification, Section 203.07 Pipe trench in-place density, 1 per 200 feet of trench per 18 inch Minimum density per soil Colorado Procedures vertical interval Classification, Section 203.07 Aggregate base course in-place 1 per 250 feet per lane Minimum 95% of maximum density, Colorado Procedures Density, T180 Lime treated subgrade in place 1 per 250 feet per lane No less than 95% of std. dry density, Colorado Procedures density and opt. moisture, T99 Cement treated base in place 1 per 250 feet per lane Density in accordance with contract density, Colorado Procedures documents, T134 Hot Bituminous Pavement 1 per 1000 tons Within specifications of asphalt content and gradation Approved mix design, binder PG 64-22 Hot Bituminous Pavement in place 1 per 100 tons 92-96% of maximum density, T209 density, Colo. Procedures Concrete compressive strength 1 set per 50 cubic yards PCC pavement, structural AASHTO Procedures Concrete, sidewalks and curbing Concrete air content and slump 1 per 25 cubic yards PCC pavement, structural AASHTO Procedures Concrete, sidewalks and curbing sandalwood Phase I Expansion Building Permit App - approval.ltr.don July 14, 2008 Mr. Jeff Peisley MBC Inc. 333 W. Colfax Ave., Suite 500 Denver, CO 80204 RE: Sandalwood Manor Expansion Project Trip Generation Analysis Dear Jeff: The Fox Higgins Transportation Group has completed a trip generation analysis for the proposed Sandalwood Manor expansion project in Wheat Ridge. We understand that the project is proposing to construct a 15,910 square foot (SF) addition to the existing 25,023 SF elderly care facility located at 3835 Harlan Street. The expansion will involve renovations to the existing facility and a new 30-bed rehabilitation center. This memorandum summarizes the trip generation analysis for this project. In order to estimate the increase in vehicle trips associated with the expansion project, trip generation rates contained in the Institute of Transportation Engineers (ITE) Trip Generation manual' for "Nursing Home" (ITE Code 620) were utilized. The trip generation analysis is summarized in Table 1. Alternate analysis was performed for the expansion using both square feet and using number of beds as the unit basis. As shown in the table, using ITE rates, the expansion project is anticipated to generate between 70 and 100 new trips per day, with 5 to 6 new trips occurring in. the AM peak hour and 7 new trips occurring in the PM peak hour. The existing facility site is estimated to generate roughly 150 daily trips, with 10 occurring in the AM peak hour and 11 occurring in the PM peak hour. Existing access on Harlan Street and on 38th Avenue is anticipated to remain, though the parking areas will be reconfigured. Given the relatively small number of new trips projected to be generated for this project, we anticipate that these trips can be added to the adjacent roadways and intersections with negligible effects. I hope that the contents of this memorandum are helpful to you. If you require additional information or would like to discuss our analysis in detail, please feel free to contact me. Sincerely, Fox Higgins Transportation Group, LLC Steve Tuttle, P.E. Principal Attachment: Table 1 -Trip Generation Estimate Trio Generation. 7th Edition. Institute of Transportation Engineers. Washington, D.C. 2003. P.O. BOX 19768, BOULDER, COLORADO 80308-2768 PHONE: -303.652.3591 • FAX; 303-772-2329 OR 303-652-6574 TRANS PC R. T A T - 1 ON G R O U P W O O N V n 0 0 N W C _T X (0 W ` a m O ~ m ~ 0 O N 3 ~ m m U) 0 2 LL 0 0 X W V N o O in m N c o - 2 ~ r n Y I O IL ~ ~ a d v a N 0 ~ 0 0 N ~ m N a p ~ r a v c 0 2 N o W ~n Y m O ~ o. m m ~ 0 0 0 0 v N m O N F6 Cj r V M T . on F ~ . Q d O O CCi LL LL "o N m o o ~ ~ N ~ a m m LL w ~ 41 ~ O O N ~ m m c a m h F= a m ' a Z Z y O O N y 0 a 2 a S c o o c y N Q N O ' Q l~l O ' ' z' a z a` z -m ~ 0 . o o 0 U N A W C O ~ C d U' C O W N c (7 r d n V W 0 City of Wheat Ridge Building Permit Submittal List The following items are required for the commercial or multi-family building permit submittal for the property located at &T~an S r-2a if any of the required items are not included in the submittal, the submittal will be considered incomplete and returned immediately without review. If you had a pre-application meeting with Staff, you must submit the checklist you received. Otherwise, this sheet must be submitted with the building permit application. Please initial beside each required item, signifying that it has been included. Review Required by: E] Building ❑ Planning ❑ Public Works SUBMITTAL DOCUMENTS: PLANS: Four (4) full-sized (24" x 36") plans Contents of plans detailed in the Commercial & Multi-family handout ® Two (2) copies of a final drainage report and plan OR Two (2) copies of a drainage letter and plan X Two (2) copies of a grading and erosion control plan Two (2) copies of a traffic impact study OR Two (2) copies of a trip generation study DOCUMENTATION: One (1) completed building permit application One (1) property deed One (1) certified survey or improvement location certificate ❑ Proof of utility availability (form provided by City) 5(~( One (1) building permit submittal list Call the inspection line before 3 p.m. for a next working-day inspection City of Wheat Ridge Community Development Department 7500 W. 29th Avenue Wheat Ridge, CO 80033 Building Division - 303.235.2855 Planning Division -303.235.2846 Inspection Line 303.234.5933 OFWHE ;1 City of Wheat Ridge - Pre-Application Transmittal Sheet cOCORPOO Date: October 19, 2007 Now that the required pre-application meeting has been held, the next step in the process will be: ® Submit land use application ® Submit building permit ❑ Schedule a neighborhood meeting (a neighborhood meeting must be held prior to submittal) The following documents are required upon submittal: ® Pre-application transmittal sheet ® Property deed ® Land use application ® Letter of request ® Building permit application ❑ Property owner consent ❑ Full set of civil drawings ~q Drainage report ❑ Outline Development Plan ® Traffic impact letter ❑ Final Development Plan ❑ Traffic study ❑ Final Plat ® Soils report ® Site Plan ® Grading/erosion control plan ® Survey/I.L.C. ® Electronic copy of Plat (In AutoCAD format) ❑ Other: All of the listed items must be submitted to constitute a complete application. If any of the items are not included in the submittal, the application will be returned without review. City of Wheat Ridge Community Development Department 7500 W. 29th Avenue Wheat Ridge, CO 80033 Building Division - 303.235.2855 Planning Division - 303.235.2846 Inspection line - 303.234.5933 www.ci.wheatridae.co.us CL 7 N Z C 1 0°o O to O c° 00 O0 ca N N. O rOmm a rr~a C m m om 3 mV C Oh-m r iO `m ua O fA .dc OOZE M Nd m wn w r Z m U. O z i Z p W e - o c z m " J t om f t Q v ~ w W N W H¢ N p > N ZVN<m W .Qm pz 0YZ.00 ccp]Z o¢U_ U x wzw, O cmp> . WSW> V~ 2' a W 7 0 c s o. Om m YS pia } O~ j 3~°a m2 Vc•. o OX W ,m .y J r Q `m J T r N m Uc0} t=i -a- 7 p Q ~U:? «mcr~ F w C7 W O m n m m'm d 2maM N m-3t~ '0 E tp p~ m =2S `o 'E ami CL N . - m W O - m°mV mm p C y O FO W m :coin°c y .m a O .pp cc.Umy `cEm` m w O W O E° « 3° o a Y xm wo m W z *0 13 c Q Q N m a« E N O.w.m 3 ~«m = E - z 2 `i. V! a G ° o00 a D y 'a .0 gym`=O.m m F- c~ H J Y m« m t c`-(0 to O.~ mLu m m 6sE2 0 oy WN cc ~w me0 O m ON. E m Jm W V N 'O m-p0 OdE-cE ° oo O O m ae J y' y y y 0 `m L.c 0 _r 7'O d c_'^av3 3 -O y o. y C O N a? O d p m O .O C m o m° c V t ~m 9m C N00 _OmmcO Z WO W L O CZ > O O y y. yq v 3r m0 0mmagi=a¢ y W zo. ya 3 o- =OV F"= ~W ra`ma n' t LLI C/) V) LL C c m m gym.. CLZOO~ C7m J'^m'O a•m co a in LL Z d C p a O U N U p m F X Y J WJ0 i Z~°3_' W O. dad WQC15~ Q.-c m O. w. cc LU Rio y W ]C7 V >Cx m E a U) N a„. S Z Q W o m m 3'a o .gym F-C7mp(L L) 0. a -+.a m m m a ma L- m- m«mam T O m ` o v o c °Lm o Q~ o am~ s~ L m - dop`oy a`mcai a°2_°1~ U m``~ me O¢¢ oy m `o c«`o °wo acm°pj-~>-,c m... - W G E E's a c d c E c 0 Q Z W w 0 m W mrn > m` w 0 m- maL" o S E O' m.?o Loo m w¢> mJ ° m c7 ~acmc-.. W mo~cmm°Ld -p o.°-6co~ >+:pm m m -cm c "E dm mc'a°iaa c.nam~c ~cm 5 » o m$ v E ° m$ `m a Z 2 y 'o o a v a ° o m C m m m m O W- 3 Q cc 6 EA a n owc"pmm - mm E~0 '>0Wm~ Q T.•.aE m.c _ ; J ¢ r m W a` c m ms n°. o3amd>` myc G W mms_~Em Omm co FO= ma r c m. a` ca `Odmv -ov d~mam CC i O Uyy,_ s a°>'. ° c ZwF¢- ? = ° m~ m Hat Ta.mOm nm vim. W m _ m m m a °aT mm `v m= =0. ¢Vw ac-m ° w a L-mL 3`ccEom°a EE C `00- H a m m _m wz0 mo d w m mW ca'3 ° - m0-9 Q~5 m CZ C` T J m" Ol F., W Y m O m j m C m " m ° J c L a. M D W C m° w a. mm mm °3 0, ¢w o a O.p ma mo.0 mem nmamyJ > mO~a+J TF- o ZOO >t7 c £ c cd- Jm.-m -O a. C N T q .O m. O LL m .r m C - U' m d« m m >i V' J O Y a r m m 0 N r C f ::E 6 -J T m m °md.U0 Rim Of7 Wn~ 0A y m6 O. E`-'a m m CA~Omm000?WN 0 a m E m 0 C it y m E p m a m m a y: y C U t 6 v 00 m. 6 p m i0 m m o m 0 r E m o n m m} d «d d G° 6 J C w_ m m w y m 'M He rnmJ c'Yo 09 zmm e_ 0 E `_mv mV cc°oy aamC9 ?,TmO m o m E.w w O l Y O¢ L° n. m_- ° m w o 3 E d m c 'm' c ^C' ° T c T m E m m o _ r- r O E a a m n p a O._ m O m„ LO ma omda `m m~« C ~¢0 yc - m° c ~y Vs mi>C7. '~o °¢'_>w c N m m c m>« c ° w y o 2 q E E m -c « 6 c m.m m '2 I S 'C° J a n w o w0 p E.a_m00 ~Em F`? yww rE D `oc p mEam~rtmawt7 O w m« a E m w W. m. m.E ° q E a v m C ' c 'O - .2 E o 0 2Z y a m t m m c m m- 0 -Oy c"oomml-c.e~0 m `m av=- m W5 E wn rF R w E m .'~`'w `m oa ° =`pm o N omm C C O E `vT vic 0c Z00 Om ° a 3Eao`v °m dimm:°.m.wmL W ow° 3 cm.. 3L m>:0 r. " Qzz ~o c m%° oo °Ow.EaO °d W _°o O °3may0 co m r-¢ ca Od c mcm9mac_J>•-.'_c ° M ' W c -m~mm Zw c E c m9a m 3Ta"jm v :aNa Y o .d Crn't J=a >.'~a wSy 'o m c `0- cmcE m>pp~ JE } `E`o rw= q m cm ¢F'z `O_ m Ea .c- w c O>>aE c3 .b o o c w_IUm L d, d „d, m m o a O C LL IL w > O C7 m C m m C T j° m m L 3 U o V- o p L.L m- EL am. OOE ° W_m Z - a00 m ° o c E m- E a .0 a 3: m° w' a = o. z r U d- ° o ` 'm E n m o o ~ m H 9 c °ma m E o `0030 ~.0 Lm Oyc mm o. wWO 0M 2 m~ o `p J~ m-Tq>JL mmm C Zm -.dEJO> mE"W Wan` gao 3yc a oo n c.o a~.ocmamcm o~YoOLo >5 ma =m c m m z 0 ro zam O - an yai ° Td E=mm ~m d9 o=mm O ° ca oEm y °E=C`OLm mE~ 3p0 yar 0m~ a cm LO ~mx -n as ma wx=a°m mwin y °m `o mE 0°O °cm y do w m 'w a>'m ~mcdei Om3 Ec„ o. 3 cm cc o y maa Ix- mo c_a. 3 W me m o ~mcE omOw~y .y =c m` ~m mo z mm > W¢ o, o 0 m ¢ m 2 E tom ?+n~ Tc - wo mmnm., w cA ~ -+LC 0a 0.. a c^Eo o.s o m v°m` a a~ ma. _>jL ° J 'mc F-W x Em o w. m EE m m E9.c W m o o me coac - m _mL ma d _m.~ m..~ C7C r dn° WC « m m .m C=,Q= .ra `6O na`am«c 0« c'.a ~mm omm com pUH0 Lim 2m..° " a ."NmoSmmaa mr C m m>q c `po cam m-TJ OO a_Ty 0c7wm Oc c°c m, n a n:: o dE wyz za w o ]m.m o.d Jac m'm nL Oy o o m c 01~ -m~ mmO m- U W <y a `m no W ma O and O rmw om c mZ v? ZOSn m a 2 W mo 1O CE9`m TM= mCO WIL- ° mm~ } NJ. v..Im m° E~ °tm r2r0 O mm ¢ [ »m.Om wn w«c mm anm W v a+La 7 E Lw W.r 0_0 c~ «.c rL Tmod01-amomm EJO mco ° cWi°a m«m >p Wc `o .-C.C3m m >-°m -uz~ °..r m c hoc- m T~ i.~onmx._.C O Z- N_ m m 0 r` m° 9 z Q O C a O LL W= O a ¢ m C m. C u a.r a O a O =M O m m O x O. - _ C W CL ¢ dLCcO CUdIV 0-02 Z m ~Lm C'-o«=m °Oa - «mm and m ~O~ 3 m and pia m m ~a OTO z O 0 Qm0 O.>' w?~«c my m mm~>``am C 1 aL~ L J 'p9 t6 O`pm U~ L Q m m IS 0 m O'E 9 U Lm w- mm nmd tLrrW ZOm y9 W6.T C. E Cmm>m Harm CmJ°6.`.m> ~M yOmi 2 32 j«E.omE oE2W *t` rwii cc a°a` DE U om_ 3 Emm9~ ma`.aE LO mdmLLLL J0E ma0 S¢mU Q>•O OO F-N 0 03`03 wcm (9 mV rao¢ amz c.y } w W co U O O W Y O rC Z Wo O m W > N LLI =.JQXo Z0a < 0=zoo z- QMZWw 020 fnZ ~ :M W O O N J to Q a N O W Q ¢ m ccz3 O Oxpu Z U¢¢Q W , M w cc O > ZE01 W 7 - 0 2 F- N H LL O 0 W W 0 n d U X m 00 0 0 O O 0 w ~ m U- w a N y F- Z c 0U ¢ m J U as a a U z y c ~ S N 5 o Q y eL m OM ~ m r y C Q C r Q Q v ` w . CL X 0 to . m C m mt m.rm - N J Q y 0L G a R O 0 LL U EO ? F- mNm ` Q U t0 Y at= F"' C7 U a m -TM CL -•LO N maw E O =corn m-3t `m a En to m m- o'E d. ¢ y 0 W O co c v y m v yatv N F W c cc :E U Z E 01 Q E a- N E o a a. U' . ~mmt `m Y ❑O: m w ~E°f£ m OLL'O E 2 =3„ ° a F- OZZ a y ? ? W Y momo o' = a i m a> J D Z O N Q m E u > m m rn m = m 9 n1 m m Z > U) O 0 0 >a„ 'O F c a v ai Q e E= W . C v c a ' Y Off F J O a E t c N oca fn: v e- md~=E 10 3 i Z N d E - O L mE F• R m O r O « E C 'O c N Z E a m m O O N r M m 9 N (7 a " N d ES E m D c O E O Y O« w N N . y U N r y N N O co L C N O . m. Y y N 3 U a ma rn« o t0 N 3'O O T m ~c3 c o~av Oi m ~ C'O N Y R O'OLC O m o"°~c cx°'aU L d.c0 o O m a m:r U 0 N 0 Y U MID m y C O Y mg o mZ ~;a~'-y m a 3L p d'r~w m N a 3 0 o o w`` y n LL u _ O F ~..,w m o LL ~ m my nw N U) C CO LL. Z m? c m 3 O O r' W O N ¢ c cm m C m y 1 Q . o w F Z 0 o c y a= a0 O' Zmm-m F' OQCCO of ¢aymo O m _ CL 0 0 m w c M g W J Q i . z J ° 3-: W aC W F- y c m o m m W Y > >w O NZZZ~ zcm3'a o LL, m = O C7 a. I a i. o. 6. c 2E vc O O O c O C 82 E a J Z N L d L.. ° m d 0° O.L. N L O U ~d>rym- vo Z¢ C O R 0 0 0 N C N= N oz y a - y O .y. m m m.0 m y W o C J m y o C E J o W -ECo n L C C (ZzW C O ° mT- mm a dEvL m. 0 co.o com 3=m yiO y¢~ `cy r C E O=dE~'E~'Eacc am m- .LE ad > o ° m m > ° c o ° ° a ac co - o CC -c `m E °mmm ma Z LO O o n ° m v °o m mo cmmm of So- o `m `o v_ - c c Z o O m0'-m0 J `o d F- >=aE mc- cJ ¢ ma a c m m" a°.-ooa„m>- dmc =cmm `o .v v NLLN m d ddoay_ y om.c ma `m c`d co U W m G m E m N c o F 0 0 i0 L L C ` O' N° 9 0 U 0 9 m C m C M. _ m y- m m d _ -m- 0 3 OU = ME m W W F m y O .m _ m N BO = a. L mv C MM J C J X m 2r -.v ai °cm `m dd= -c ¢Uw vc-. ° H a mc3ccE°i f°'mEE.rd Ndm C d m m m m a d d o m m- v `a c `o - v y m Z O m o mr o= .y c a:m w¢ Jr m _ co o._E3L .>mo`m ay.r=c c o Z c 2 - c m- - a r our _ v m W m m` d E m C L Of H' w r0 'a a a i0 -a E a d m E M m rn me E mO~'H ma aF-3 °-~O zoo E 0vc7 mH3c9J `o t'°°m.-mF` 9+' T m ` -LL 6r m m d`o -"c nO c -c Jai mm y E °p OIyV CNO mcm OO WO.~ Lm 'A m6 6 Ems'L NEC - m~000L nom. F' oa o m m~`c E0'r° Ec w mE a m°? wm~d° o >m`ooa~c°~Em°E co m- ` m y 0 H y ` w m H L m m J h ay moa C.m ~j« c r mF• c. tr oEmn°a (7~ ^'O vo m.'_o o2 2 Z-m o -m a9 ai~mr`o o acaM ofmo ct v O c a ~i E ~m m mu xc-`-° >>'mm ~a C O, m m - O d O m y o.N _ > -m 1>-OH C7 n E n v IL o.°-n`8 E°``oo>m m c C _ Q m d m r m m L m m O« o m C ~ Q O- C o O- c J° m Y °0 a s c7 y N C -o c « v cm N a r m y 0 N C C E y m y t j C r _ N O s a m U j E N Of > J c - O w N o ? m m C O N m C 0 n1 .0 c C m a m C cpp N Em E a E m = E a ~ N w w - C= ° m o o c. E a 'd v c W O o c w m` a m amE o E an wz0 0_ m m 'a cm o-a cr~~mi=a 3om y -mo dO t°om v° Hwy mm £ a mmoOC`Y_ai c mSv o_V N `Acm«;am ytE ma dE Edy_ 3 O m W " U m >i m Q y m° = ~p u L y L m ° f- E J C m N C O F- c. _ t: `m uo m Z W y$ o0 y m~ a vELo`mcm aym do yom 3 °°v `oLE> m2 £ c m2z E d0 mc~h_Ea0-aEyEC°mc_vo'm O c 3'm .o y `o r m° c o d~ ¢ 5 c O m o y v °f.m y r T '0 V m m Y O m N s L .O ¢ F H d> E O M « E m J? m m` E C j o L O° ° o. °y m m y E`o >,d m m"E z v« cv c c ° c ° m''v co ":mu E 75 t E `y d d m `p n C U C W U C7 m C m m c T O m m 3: m a y U= O 0 m~ EL vN.` O O ~ o'c w m g of0> c o`c E E o ma« O m dv3y`o m m c - `m n ~ zz...U 0 nm > C m` 6 m m yca`ao ° fmmHccm c°m°"O 0 L- m C O d f y m ` Z 0 3 U>C m O m C 61 O W o C w O m m m `y O 0 J m_ m L> m T p L N d m m E yd mcoT mE~- mcw ~~0 3mc Q. oo a coaugcrnnci°cdL^c3`a cc>m O Ecc.°OmE ~E= cmc Cz-7Qw scE O da yai me>a m~~v° w._ c 3To ° OmE°-.6m, Oa my £,oc C 0 o ° yy v_f - a;E N `o o. c m x v m mm `mo°L. o°O °cvy N m o w m5 c> .a Tm3ommm um c~ N °m r E Z ° E mna ¢.w m j0 S E m .m.y ya ~~N„cd,3 ~cEE>°cc0vm° i a°m`aoE Som Ha`y S¢w~ Ndm LL -oc> ~t c~-mo mst `>•?~at~dnmo v~m' a.5 a 3 mm t-WS¢ xEW O.. m E.o mm cE~uy o oy`c°`oa c_ R ci0s ma°u oE.2 etc Os~~ w~¢ we rE mm c~atEv~nv a°--Odmccmy a.C T] °y_ r ZOW 'd UO "'o y m 7 Cm cd OEOm and ymJr N °ov.m `m y ° n- 5 m E`o d OW I- C7 uiLt Zm m a EyN mot mm aa` W >°cC7 y,°a O a °1 OZ U a c 6 r Jp y C J N Z 3 z y v Z o 0 c O m J.L.. C E° O O- ° ° O- N° w c o u Q c a m o _ m a m r c _ d m d a Z m y Z D W O m f- a a m > o o w d m m m y L J> E° y m O ¢ J m O m O C m m f2 J 07 y (7 y W 2 H.L. Z 0 C O ° O" E-5 a O C y~ 9 m t C Y N X Ja°r EE 'y'm o hz~O O mr Q C Oai v m Em am a m v. d < 0 3 a M- c w m c m m j w W¢ H 0 9 0- A m " y 2> m o° ,r ` d Oa ? o =g Of O_ ¢`o o `m Etm U `°-a " S 02 W Do c a-R - `moms En~2L `o L oy-pots 3Mzd~Oz'a~zZmm`"5.m0Eac >>;co a cv>- L ¢ W mt°na SC m= cc o WNNz Z°y ¢ o E c~'oQ moo°ma-om dr Eu LL J y >i m ° > m m N m U O Z 0 ¢ U d Z> 'N Y o C 10 y m C ` m m C m (9 i: o -6 . L y j d O J d a1 tO>y m m 0>00 00 Oa N d ° a m°oP.' m •o.y. E d r rL-c~ C N D L 0 ai r ¢ 'O C _ W H y d O m m O O m 'c m U m y 6 ` H W U N 6 C c m y> 6 0. d ° d J 6 r m T m O a°i of Uo` 'S a`m'm~Ema °Ea`OaaE N ~c+f pmE ` d`8 `m Dro E°E NO JU 2=P' N? t0 Qm mL LLS:ocE _a 2¢mu ¢TO 0> - co F-U««a3o3 iLLCm C7 M0 F-a0< e_Lz srn Cl) and^O y m id -Ldd 0Tda00 w m L d> W L m L ' ° ya o,a>d m Cad - 0 c w m m m o T ` > 3 c x c o w°« a d o d G 3 ° m-o ° a m m W s J am o m c m ° d c o o m . c a v m E m m W o d A U d C ° j L O} E C w m C m a -C I N C7 T O 0 d O E ° ~ LEm;a o°~ Eao`c 9 .a og o m > U ' E "mc am_c7moor m5°-° rdo a °-'oTa c- . ~L. E,m, vQO oa ~a°i t To E~aE ca3 E omm m m m n - a o 0m„- =a m or c ' r ym W m m w ..o a 0 a a a w m= J a c c d d L 7 m d o_ } v° c H o E m o c z c o N a o m- v J L m a.E ~j d ac N o E a y o E o m c N r d a d c; y a o m N a v m `m c y o cC cocv ma L'c a_dy - oa m _ mr3J ° a a m m. 2.6 °c a o T c m a ~ :o La c° c c m` E v `m y m dcz c'= ca'3 E -p > C c - ` N~~ m EEE~o m9'E :z d o ucmJ ` mt°Ja m m i a } d a a r 0 a c c O m m a `m L- a m m m° d a mL, c m`L ma E L ~5,2 y `m " a g o d m'E a m T cdi N i m a L J a J c m r a m ° E p c . O m 3 o E c E n E _z o J o°y0 u°rva°oa m°O Nm 0.0,-do a- 3 E ° m a d 1° y °o .On ` ° 0 T ° o c a z O c ' m Y a J.nC a W JoL EN W do m a C JyO W d E o,c° 'o d -O mmnOd Ol LJ a = N~ C O d J Q W a m s m w C~ c N E O° O !D O m° t w E L -p `o o° m o: c 5 a d a c c `m > o o a> `m t m> o 0 ~ W m N L c m> E y _ . QI ~ C d J O' E r N c „ d C .r O W W « m a ' a E .C L ~w> y~ yoaa°m~nd~ m0E wm ~-o~ o a ' Q C m a b o~a o~- c ` ' n Lr ?o t c.o y wc °a om o - mm` EE~ m O ° _m_Ja ci°adact_m.«_oamc ° csima-5Za E~L°ml L LU ° 0- a m t y - a `m ~ c m c a J N~ 5 c m E a c_ t o a° 0 O V C ° W 0 U' 6 N C d ry ° C d C d d C` OI W T J c`°_Qa cy- EEa `m y a m t J C v d C C y W d W d r L mL m'm o d d L m W - L m = dL d o' C p Ip 10 m m a O 3 d a o m ` . J m . T N a L ~ 3 = W - O U maE„3Z.amo m y a c ~[7 d O C- mdZ.- oa am wmm W a N L C r0 O T t . . V" J J p'.' d m m d L _ 0 ~ o y 0- c mam~~ y my n ao,~ WJ dat> acE>x3maoca W W m y Wr o ° Nxddm acN T>.`d"'~ L ' T L L amm«m a c y - C V ` 1° o a a= d m a m E m N ° J o aYO'a -m mL m m T E m 0 c -c m dr 1° a ~5 V.m ~ n yd mmmmmJ ' iO co mo~°vo`-°Eao C 0 m 0 a m m° m` ? doa aWE:a a 3 c L 0 w C c L m° NL ,'aard ad T ` a O o C N j aa J...o i a y o W W O_ E O L J c d O >T m m c-ddL W C a C ° O ° u V d C m d m N 9 ° U L Q y Y_ N r t O 3 j a " O m L= C a a m C w T E .u ' o _ 0 m c 3 _moo0 r i"mac waEuim.~ ; cm w3>m ~ y Lnrw c' -v ¢E }c W£cd T° cm ° N w>w ac d rm °Om> aa' NOmt a' « Tmm my c a d c J a m U > U a n y 3N ¢n W E ' a m d a a > o c ` t o 0 0° a T 'm c t - L m a N v a=t a'E d « d mN o Q c a.= L rn co O"m`m m E m a ~ c c Z o a O N m ¢m L~°. « m v c 7NO a'rt LdOmL'-N . o W mC yL 4610 WL O C a a y> E N y U m y m J 3 am 1 J X N U J c V J T J C p O r N Z m .y. T N m (l1 m m C m W -ay- a N a-Ei w a vl y ' ° a Z c O C d z0 0Ea°` .c9~mc N C J d° W °oaEy ~E. _ y m C E d m `o T C7 a W J Q d N Y N C 9 o N _I n d m W w d° d E L j ❑ W d j ° E d'OC U 0a w c C.d.aUmO O -aC}Nc c m a o J wa H~amEa>E mm m a a~a om m m m c m M a O L L'~ C O C o 0 ° c a a - m m o m w m E t ~ C9 c] 0 % d V a,a-; vG7 m C L « o;~ y m N cc - p` m w> W y o a d L d v U. m n U a°i C C ` O_ a m m o 3 o C °L c J o N m Eca v .c occa d N c° J> a o $ T m S d u O._ L N cmE 'oar°m~ ' va E -2 a c a o m °m M g o W m a 0 w w a c w c m L, m 0 a cp m-r a $ _ E c y 0 y N C u c° d C cL. c=° c m ° rnrn ~ O V w~ m ,dy m- W C a m U m A j a c °mcc °m~ wC d m O m O L n° ° a 'u J S O N°- 0 N m N u0 m C m C C L 9° a 2 t° - m- ~QU? d m 7M C7 m m m m ~n EF- L~~?a.3o at 3 J u y O w m N m m C m ~a LcJL O9 arc ¢ c m n m H m e d a E t m o y `I) L- ° `m o w c o -m _ c ma° c ~.a L. m~~mco mE mmc a W m L E ap- ° s.. an d m c 0 d r d m m a= L y J m= O_ r N as ua c c~a of sQ y -o m 0 a °m m L o o ° m y. T L m a m O N C e c O C C m m a o$ 0m °n mod c-a _-J dmmm E mm ma'm c.c x m`oa°. 3 o, as (7 O m y N J na o - m > m N To E L cd a a c' m°y~E_ me coo O C V y O (7 m m O m m y O C E N y V U mL m E w.` V C xC7 Y C N J a 3 F r c u N C m N a y m` m C L m E cc cm E Ecam Lo m>'n `omo3 1-m`c °c~~ ~'3 QyH daE m a E~ c m m M O m L Y y `m C m' O m U'NmL m~`mCC m-q mHJ' m m2a°0' m'mJ ° ry E° H H 0 w N w p H z Q Q 3 =c d -d L L OIm'O0 c L L O 01 O1 C C Nym ° L L a° w t a NLc J q . W m? 3 m y a c r o . . > c x o E o ac°+E L 3m3 o ` pC7 c.o c `-'w> o v a°a'm c nmL m c m m m v Ux 0 c d c5a m pCO mo a c E o a v V n m c L J - c o E c o m a 2.c c a s 3:R c 3 ~ m m d C L N_ c y a s ~ a - w ~ d - 2 c H w`.OE yo oy 'o m- 00 6-` c 0 . N m. oa d'o c~ac o a QE m¢ ~`Em mEA° m m. a° t `-amo m M2 u '-o p y cEc a 0 Mc 3 -.s cy c°x o`a t o a a ° c d o- ~ C o 0 0+ c° c« 1O - `o o H ` p d d a ~ o C o o U V J = d m w J O' N v i ( E -1 m d _y c 0 X O d m N . - W. a yam Ec °«d M = Lcva Modes Ll. ° =.E `oa` N a 0° ~ J J ° Y H 0 y o o c a w 'w „ , °c C m ma amt - o- r E o , > 0 - E w d y? 6 y O O a m T V a a y E c c a m o c d ¢ O U r y m c c E m N C L a j L J a L y OI m h _ r N y U m - O a J m m x m C ` m O Z m O d y a m O c t Vy Q N m W m m V- an d O d r a c y m U an d y J U L a a- N m d L j N aot>.y va. a W m (j n`v0 a -m 0 w oCD a 0Ew3 n rn mm O ca ° _cwc >c~o Z $~a ~ d p yy dt.o y L '-a E Y a mm.~ 0r m t- w ` ' -o om C ~ac 00 da~o - o m m a v > o c a r N y m a J n n a 'a o o c d 0 0 m J13~' ~atoE ma a "0 U m' iG p L L m Ua C N C `a L oa°u°i °o m `oh m m « ra m L roam o.: m H 0 m ' o V o` m Y _ m m c m 3 0 N a E c Jm o w m ` c m o€ E m a h~ Qma c E m m m m o X° (7 y d Q N N N E L c N p m m W awe ° °9 ~d ¢m c:'. d. x mm`w a d a m u0 a a a w 2 m M.2 E c a o c a c hW- OvdaE c Jd o 0 U Ocm= ° > E'm 'u jL 0 01c t m > c7-+ Q LL__ . 3o ' c mcL Z - s0 c ° 3w 0 cm y ` .m a = m Q . mm x c U= L oamc od mE E co E a a ` 3 tt- 0 O my ° xNC Z mN c_ N m m m _ w ma''r «mJxc Z m t°a W aam°+ W V U° 'a«amm >'m 3m m Z.. °uJ o Oa MC cN J wp.01 E a 0I-J z` a T N C O d` m w >y d U a« m 01 = m L m tt I- a L a m N C° m m W m J m m c C ` C m ` C ° a V> H O +.O UC mdcp X° r IL 3JmN J J 0 aO'~0 mmaC~ N Wa - y C.O J L N Z C m c F m w d H H m O c o o m 0> m w .r F- d al w p a o m L o o E x O y m n° ° o t m a c` m c a 0 m oam N y ¢ E>.o0m -t~wc m ~cEd m F"_mOj mEt ~ .~o a °'aa 0a ~40 ~ m~a mLc9'j « oEz o, . _ a°amc WE h `mmh xm~az Lm.rp M ~m a. O d Q d 0 at; d> O F N ti r .F- 7 w r C IA N O n'N U m° ° W m - Of N m Z O H Q Z w p 0 U m m N E _ d N ~ E o E >o m a nw o a a a m E m o m c ° w00 CU d m d E E O O U cc E Ea a' 'c a~ Q d T~ ~ d U c m J ~Y m wa «a y C J ° V U N m m H` 0 C N w L J m ° L H m c m m L m H m m Qa « c m j J m c N m LO m m a Cl) J '6 Q~ U. O~ ❑ O wU ❑ N O O O Z c R O J m L m m L H m a J t m a O m C H `m L U X d m O a c d T m 0 m a O C O d L O c m 0 « d ~a nU c W ` m `o E E 0 oU v E d o E ~ m L t 3d a ,C N 7 m y o m m E a m m U J U ° N U y C n U O m d m o _ - a C H C C U C O m° O y C m m O C m L W C m y W M.21 S • Emma y aoa HO.. a o am s t d O V V m ` X r;,E ` C ~ m ~ q T m m c o m W J eT,. ~ O]~ E. d m m C y E>o as o `m ~ °c mm c a ° W d c J i°~£cmE `o W > o a v C O E C N'y a > _ m x m o J° U a m c c o m c o°m r 1O m_' W °'c°io~EoE m ° o ~ c d-O r n L m C m p O L. C c C N `o m « a " E o t c m c~a5'c `m U• 6 m T V `m j d o mn•-a rn` ° a c m V 'O m em- m J m W 0 E n 0 1° m > $ o m c-o E o a-` nJ o 0 m C m r c p W a ~ c m `o m r >m o 3 C J c .m L C- m -0 ° O ° m. 2 d o ° M ° y Nm m y a L c y T N mcra y ` c- > a ' d 3 N W p v r - m m `m L C U a C T S 6 N o W J N E° W L O 0 N m t c E N C C.`°r ~ m T r d 0 o E `E N C y a~ N W OI c m y a n E m m C m W m .m. y m Q J m S a c n E m O m a O m L y U « C O io L 3 L- ~ m m o = c L L _ O m F C m iv J o d y ° y = c o m m a a m U C ~ m L° m L C m 0m t c d N N a m a x m ~ x d a m m m m _ C C W L N C Ja m m m J o° c r T C E'er m a o 0 J OI N m m C V 0 0 ~ m a C 0 c ~ E._ N Ln m T o do °-c m m ? E y N C_ N C W a° E E ° v c E m N m c J o x a~ 0 0 v a O` O a m 0 r m ~ d o o~ c o C R O yO U o m a- W co m m a « > W a T > ° a N m m W a c V d m o m aci c a W ~ a m - m «S L O m m m m O T E d o a m a m > t d a y> 0 o~ y c «mr. Nm 3 t > m E m m L 6 x E > m ? = m `m x ?'m m E W a E C m c a ° a r W j U- m m d d T O d~ U a £ c o 0 rn --0 ~ao3 m O d 7 m'V m y Nr m 3Lm. c > ¢m OEE 10 0 C V O 8 a O L N > n 3 a Y c'm m m a n. m U m n C Q 3 fL EL.. m W `m `O t m •O d m ° V J C ° W E H _ O W W > d N J W O L O a m „m, W oc` Z a c m m > m C L a m m `o m r m o L O o m ya0 ~ = p o m m a N m Q w L ° 6 C > N O C a Y aE mc7- c t `o y d C `y ~ ` m L m O mma, Y m ° n J y c - 0- J O O m W a E a d c c m da m Y a-O m° L o J c m m O r J L. m ` m r h O - a O = J arHm m dram > m`o A c N c m L m C0 E E'wm E N m N n m a T Cod a o C nm o m W o L a J 10 a p L O = y d m c a N L V ~ L m J > ~ J 0ao m~ wit v'E m Q W N r ° E m O y W C c `m y p m L d E a 3 F O J a 0-0 O M- L mo coc O U O m O m m m °-6 m a° C y d L'°r O m a N N r C 0 c c - a m a C c m m c S U m m~ a C V N L O m y- O m-y 0 `m m N $ W a a` o c m c y a a a d `o c o o m `o c m m a 'o d L m 'c o W y a c a+ o° moo ao0 aL~d w ` 0 W C J O m -0 a° m W a a a ` a t 00 E a m C m O 0 !N a d ~ W ? a L a r - o o` ~ a d T a m ~ a m 2 r ~ f- y n cop `o m ° `v T ° a y ~ am C m~ m d U m 7 j o y 0 J n m O _ V N O N m m m J L m N m- a a t o ms a N n C m 'C c m - a m v c d c C ° m L d a m~ C C N m a m° U O r y L C C L p N O m C o m o e p c c a > o « mmomE _ c . 3 N m Ot« C O N C C m c co n W m m m m o E h a J `o J W an d- W N_ 0 ~ m «L• L C q m a c t N 0 T a c o '3 mamr m Yaa W E L 0a r c d ° 0 E° d 0 W J > W W o° E . L naYl N O. a.L m OZ L.. m a y 3 y ~ -J m V W 0 Z d y U a n O m C to d H d t y F- 0 ' C O ^ N CO d m 4C m ~a' t- p m' r- W N 9 r r MME cc2d o T y W_ J C 0 d m a c ° m c y Co r C oU m J T c y ui D E c--` m o m o y a m m o d 0 Mm- m a ` C ,mj W C. p d m j ° i0 m a. a`o-°a ° y 0 m y x a T r W U Ea ctm W oc -cT x°'°i~-m°~ E m N m m C y Ol O m 0 J a CWa a o a `o m r a r - TmcrmE c_N3 c'T °m c a = ° W m m O v°i c W E m T m a T- d `p E m C d d m d O m C N` O ° m 7R,2 o "O a.d y m m m y L x` O m N y y y N N (7 C car m N m c a 3 ° E a m Z m"~ E m L m m> U m O C L O m a a.N L c v° a _ a cTm° c o ao C 0 O r m T m~ccE;?m _ma rn o a E E c o m U C-a _ c U E U c t an 0 c M.G a O mm-OLm3y°`om Q m. W o fL/1 m W y E m 0 y m m C a W O V O > E W C _ N m 'r °'Ta._._ E coo `m J C c c a E o c cdN'N W E E =.C m an - N m °I m m N 3 >O _ a E T C J W - °'C a c a c A° H coo ~ V m m O C T>. > d O o X V m° r O L T E a t N mm~yam 0 c'~n m° O~ C> d a V a J m a C C a O m° C N 0 E m W 'c = o. p m W O _ N_ m T y _m m m T~ ,r V L m m L N C C C«° A O o a m a m - c L c °1 0. o o y y W d ni x ° c 0 Q J> J W m m V._. 3 W m n d 6 a a a c « x m m F- m « N C ? o o y .N. N 41 " C d N a N N N N C m «L dL_y > .O c C .r N r y 3 p~ ° J~ O m m a >d N T m OI ~ C m •L" _V m mL- C W J L° o aEc~s,mmmc c 'm m a m m m a as m° c c a r;`oa °o m5o J m.N F c V m O t a m m r O O N m aTarp ym E `0 a c d c H- a` m m> d c 0 E E N 3 cy~'o - c OM 0« W C m O E m y m c C m > r J W m 'Edon yc~ C ur r y `T, C O_ T 9 m m a` c U - E'CL y W° a T a rv 0 E c EL mmmE aUd 0 0 r v t o t a m E T m 3 y'« 3 rn c c > rn c _ c E m m E v Q c> a a > _ J O a r m O 2 a c C N U a m C W m 9 m` m m V _o 'mom y°E c r~ CO n m N O T J m ° ~ E m o m C c 1O p L 0= m m m- « m~ na C d m C O •L"' N m J W U' 0 aEL.. y U A q O- O U' c ° m m m m Ema£c m m L d y 'C ° a m m m a a m a r °1 m > " r E ` 01 ° W E o a o $ c ca`om m°_N atO9ay W-._~m omac,a0O 3c7` 3 ~ v o t o N= a my o an E C R fyG d N OL J 0 W C_ > O - > na >L U N._ ma c rna =E °1od c m r Q T'C Ta~m c °Q . W d m Q'~ m_: w oti ° a V w ; ~ O~ o m 9 c7 N m OJ O > ZoF L W d o O m Z `omQ$om ao T=L- mmNm C~ W N c ~ a m m c a°O0 E o0 5° .o a `m n y - m rn o T` J n m N m m y c m d m E -0 ? m a ni c 0 a=>~~ > =a-o m ms,_, m W g C W y= W W E W L m 0 ~;NE ~`o o~ tEcam r m m _ m J a M o o `o m- a Y W 75 O.>``y.C NL.WrC a > a r C a~ N `"a` _ .L a Q I w m c m` m W ~ a c Q m c a 0 3 c ~ . m m ° m c m O y C N m o y $ m `o rn C Lr N m 0 ~O °O-paw Et N N a L r > ~ tq O 0 U C O m a m ao_ m° U 0 m y L O Lp m a " m r m x N C- C + m m m H O O a0 O J ma N n m m .Cj L N 0.] m u U _ m T m K N ~ C r` a m O N W d W ° o m WT a> o_ a 0 p o c E U m o a m._ E o m > C L C J « maw N'~ a c N~ c m m y o y y E am o'o _ N° W N W m m J o c L° C7 N -mm W x J a w E m o 0 7 m W y a y E m O r W m y N .L.. O r a J N d m Q N , m N a C C W Wo ° W a 0 W L E O. In m N m W N J m_ L j O m X« > c Q T W Z -0 Z U m m 0 C c o Q EET-w I. E'a ~vo->>OxoE>m'LD n O > a m Q vai W n 2F nny W m c L L O U N d m L T C .O m C m Q J V C m a 0 E m~m ~c m' c m o.A m m `m m p .W. mt m2d H c n m c y ° m ,r L ~ N m -Mm T z m ~y a ° a m ` ` c o c c o -E ° m m m . C O C ° 0 m m x O _ o ~ a t o E c E L. o Lm t a O ~ y N O d o . r C O - T C ° J o W y r m o c Em min T °u ~o m a 1O c7 c c 3 c m m U 0) d O « m O ` E a c o m ° o E 3 d n J ° o ma W O n h p y o :y o t E y m a a m o O O J y W a . L ,V m y m E m y 3 a 0 d N C - d m L. _ d > > Y T W 0 E Em o a'~ 3 V Z a c W O= •T. m V d a m O m N O L ° L .d C 6 d W E T U W m Ql - m a y c t. ~ m~ a ` ~ ~mz c c m o oEm ° o m C coo C ea a a c a- o- ° y a m yJ. >3 Y 3ta 0-0, ` cmm 0 d O m O ° O p1a o Z ms m 0 C m rn m- o y c d a o U rnt n O o c o d 7 L ° y S O W wmc= N ma L 0 m'`o. H m E H c c a p - F-N O dnC y'~ ty d0 oN do Em y L E>, .°m ' 2 6 y EC £o cc o-N m dm ~ ° OI L E f' m O ~ N O y Nn m H - W r~mE M ca m~ m ;L . m « m U d 0 m m J C a m t ~ m'mm E' ¢ aJ Sm Cm. C > E 'O N- a J c d N W a c c O m o. u c y m rn a m m S mw QEOX U ` ` 2 C 0 Q o a D - N Z O 7 Q a N 7 O Z Q J U N 2 ~ y L m C L N ((j d N ~ E m r d m . E d= c O CL f 9 m m 0 ° L W O C o E v ° C7 N 0 C - m C a c m ¢ O C N m V F E c c Q U N ~ N n ¢ CJ ~ m m U m_ ❑ a d Z L w d ~ d ~ U U O F 0 c y C d ~ ° d - N L 2 C LL O C ° r ~ = o w E ❑ o w d ~ via ~ p L F w O a N V7 a d n o c = F- d c m o O F- 7 ~ ~ c r c m ti C G r O E N Z O G a` o E L O O n =m c L d > wU V ¢ d EE3 0 LU t - m "E dN a " d. > d0E 9c = - d c m 1OE 7 m r m E b - U c C J _ m 00 Q - 6 m d 0 ¢ m m o W C m 0 o d - N m ¢ "E W` c ~c c CD m d 3 m z ¢ ~m ad E > a 0- O N L L eN.r F- 0 N C y " E o p o t c: ' d a` j 3 I- . Em0 a of 3 . N t T Umy vi 3r. O ~ m E C d L 0 Y O ❑ G an d m O p a N m 6 O ¢ O Z o .m m e=c E`8 vi C a ¢ ¢dm5 ¢m Z~ Z f0 0 w O H C7 Z LU G C7 LW VW J O _ z ti Y U a _a 2 U) cr O ~ L 0 r N r Ea a. > ° o a o a `o 3..am m ❑ z O c N d 9 s 0 d L ~ a o - rn E a ° a N d m d d L 9 w O ~ O c z 0,02 y d z m ¢ ' L a O C p a d d l l J d J ME- E<°1 ¢ ' \ N O mw 3O m c ° a m Z c " o ~ C E y ? d Z o d r c O ° 0 m . . O dl r J " m m N a 3`am ° E N F F r 0 O O O - N ¢ n m U _ W Z C•. a a o m 1V c, V \7~ Ww ❑ LL o r h Vo 0 w z y 00 ^ c a c y' o rn M g❑ -o M U c ° U ca C) zj- c Y•c'TON,° 0 n o° c 0❑ o> a c U m ° z O ° o -a c rn ° U as d o ~ 3 w ~ a U z w _ Y w L VI ~ ° .a Q 00 'O O \ N rUj ^ 4 ~ T aw y m W y~ `a ° N y V] N ° U U r.C i 4 w w O m rn C~. O U cC N U U O° U U O Q w• O C T a> w U P. r. cn Q) Y ow `a ° ~rnrn w~ Q a o O co °o m m°° ce) aG C) Q) ~ GO O k. U ° Q W a0 Rv°J " y U ° U T O i U] 0 0 0 0 o p o b ° Y U cn w M _ c n W ° o U O W e ti X 'a w G Q~ p V] N cH Q 01 . Y V] w T pUp Z d F U O N T p p M 0 O r P C14 cn IM. 0 O O w O C N w U 0 to O N U T+ r "a xd = ~ \w caz o °J Y cz: C) a) m 0 O 0 ° U n o O~wOM F 0w yC y yN G O Z) o v 0 cn ° 0 N On 0 -a 3 ° ° 3 a° M M 0 v_ o . > too p. (l^ cn V4 , w d 0 0' U a H cis U a cn cn ° CTL I THOMPSON GEOTECHNICAL INVESTIGATION SANDALWOOD MANOR ADDITION 3835 HARLAN STREET WHEAT RIDGE, COLORADO Prepared For: ST. PAUL HEALTH CENTER 1667 St. Paul Street Denver, Colorado 80206 Attention: Mr. Richard Whelan Project No. DN43,463-125 March 20, 2008 1971 West 12th Avenue I Denver. Colorado 80204 1 Telephone: 303-825-0777 Fax: 303-825-4252 TABLE OF CONTENTS SCOPE SUMMARY OF CONCLUSIONS SITE CONDITIONS PROPOSED CONSTRUCTION INVESTIGATION .................................1 2 3 3 SUBSURFACE CONDITIONS ...................................................................................................4 Sand 4 Interlayered Sand and Clay .........................................................................................5 Sandy Clay ....................................................................................................................5 Bedrock 5 Ground Water ...............................................................................................................5 Seismicity 6 SITE DEVELOPMENT Demolition .....................................................................................................................6 Excavation Bracing ......................................................................................................6 Dewatering ....................................................................................................................8 Fill Placement ...............................................................................................................9 Stabilization of Loose of Soft Soils ..........................................................................10 Utility Construction ....................................................................................................10 FOUNDATION FLOOR SYSTEMS AND SLABS-ON-GRADE Structural Floors BELOW-GRADE CONSTRUCTION 11 ........12 ........14 15 PAVEMENTS ...........................................................................................................................16 SURFACE DRAINAGE ............................................................................................................19 CONCRETE .............................................................................................................................20 LIMITATIONS ..........................................................................................................................20 FIG. 1 - LOCATIONS OF EXPLORATORY BORINGS FIG. 2 - SUMMARY LOGS OF EXPLORATORY BORINGS FIGS. 3 THROUGH 5 - SWELL CONSOLIDATION TEST RESULTS FIG. 6 - RECOMMENDED LATERAL EARTH PRESSURE DISTRIBUTION FIG. 7 - SURCHARGE LOADS FIG. 8 -INTERIOR FOUNDATION WALL DRAIN TABLE I - SUMMARY OF LABORATORY TEST RESULTS ST. PAUL HEALTH CENTER ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463-125 S:IPROJECTSWN43463.000112512. Repod IRI 0N43463425-Ri.dm Ez~ 71 r SCOPE This report presents the results of our Geotechnical Investigation for the proposed addition to Sandalwood Manor, located at 3835 Harlan Street in Wheat Ridge, Colorado (Fig. 1). The purpose of the investigation was to evaluate the subsurface conditions at the site and provide foundation recommendations and geotechnical design criteria for the addition. The scope was described in our Service Agreement (No. DN 08-0103) dated February 11, 2008. This report was prepared from data developed during field exploration, laboratory testing, engineering analysis, and experience with similar conditions. The report includes a description of subsoil conditions found in our exploratory borings and discussions of the addition construction as influenced by geotechnical considerations. Our opinions and recommendations regarding design criteria and construction details forfoundations, floorsystems, slabs-on-grade, basement, and pavement are provided. If the proposed construction changes, we should be notified to review and, if needed, revise our recommendations. A summary of conclusions is presented below, with more detailed criteria and recommendations contained in the report. SUMMARY OF CONCLUSIONS Soils encountered in the borings consisted of clayey sand and interlayered clay and sand near the ground surface underlain by sandy clay and then bedrock comprised of claystone, sandstone and interbedded claystone and sandstone. The bedrock was at depths of about 17 and 18 feet below the existing ground surface. The sand was loose to medium dense, the clay was stiff to very stiff, and bedrock was medium hard to very hard. Samples of the sand, clay and claystone bedrock exhibited low swell. We judge the sand to be low swelling or non- expansive. 2. Ground water was encountered during drilling on February 19, 2008 in test holes TH-1 and TH-2 at depths of 18 and 17.5 feet; respectively. When borings were checked on February 25, 2008, ground waterwas measured in test holes TH-1 and TH-2 at depths of 12 and 10.5 feet or at relative elevations of about 89 and 91.5; respectively. We understand the proposed addition is planned with a basement with the basement floor at a relative elevation of 88 or 90. Ground water will be near or above the ST. PAUL HEALTH CENTER ADDITION TO SANDALWOOD MANOR 1 CTL T PROJECT NO. DN43.463-125 SAPROJECTSIDN43463.00012W. Rep.MIRI1DN43463-125411.dw proposed basement floor level. Ground water will fluctuate seasonally and yearly and will likely affect the basement construction. Temporary and permanent dewatering should be planned for the basement construction. A basement foundation drain with six inches of drain gravel layer beneath the basement floor slabs is recommended. Soft, wet soils should be anticipated in the basement excavation and may require stabilization for the construction. 3. Our investigation indicates foundation soils under the site at depths likely to influence foundation performance may include loose sands in the upper non-basement level and very moist to wet clay and sand at the basement level. We recommend the building addition be constructed on footings. All existing buildings, pavements, landscaping lawn and trees in the construction areas should be completely removed. Loose/soft pumping soils may require removal and re-compaction orstabilization by crowding rocks into the loose/soft soils. Foundation excavation for the basement may require bracing to avoid undermining existing footings of the adjacent building. Dewatering may also be required for the basement excavation. Design and construction criteria for footings are presented in the report. 4. Swell tests indicate low swelling sand and clay are present below anticipated floor slab levels. We estimate potential movement of up to about1 inch for slab-on-grade floors. Structurally supported floors should be used if slab movement of this magnitude can not be tolerated. 5. Surface grades should be designed forrapid runoff of surface water away from the building and addition and off of pavements. Roof drainage of existing building should be improved. Water should not be allowed to pond adjacent to the existing building and addition. Excessive wetting of subsoils can cause softening, swell or settlement of subsoils and result in slab and foundation movements. SITE CONDITIONS Sandalwood Manor is located at 3835 Harlan Street in Wheat Ridge, Colorado (Fig. 1). We understand the existing buildings were built in different phases in 1972 or earlier. The site is located in a mixed commercial and residential area. An asphalt parking lot borders the buildings to the east and irrigated landscaping and asphalt parking are south of the buildings. Courtyards are located in the east and west portions and in the interior of the buildings. The site is fairly flat with minor slope to the northwest. ST. PAUL HEALTH CENTER 2 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 - S.TROJECT61ON43463.000112512. Report IRIONQ"4 125 1.Go0 The existing buildings are one-story with brick exteriors. A laundry room basement is located in the center portion of the building, adjacent to the east and interior courtyards. The existing buildings appear to be in a good condition. We observed some roof drain discharge adjacent to the buildings with no horizontal downspout extensions. A detached existing building is in the south parking lot. This building is a one- story, masonry block building with a garden level basement. We understand this building will be demolished for the addition construction. PROPOSED CONSTRUCTION The addition will be about 15,000 square feet and constructed in the south parking lot. The existing building in the south parking lot will be demolished for the addition construction. The addition will be one-story, wood-framed structure with brick veneer or sidings. A basement for the new laundry room is planned in the northwest portion of the addition. The addition will have the same floor level as the existing building. The new laundry room basement will be 10 or 12 feet below the ground floor. Foundation loads were not available at the time of this report. We anticipate relatively light foundation loads. The existing buildings at the northeast corner and the east courtyard will be demolished for the construction of a new surface parking. A buried grease trap will be installed under the new parking lot. A buried storm water quality vault is planned under the parking lot to the east of the current east main entrance. The site is fairly flat. We anticipate minor site grading of 3 feet orless. Deeper excavation and backfiil estimated about 3 to 6 feet are anticipated for the demolition of the existing buildings. INVESTIGATION Subsurface conditions were investigated by drilling two exploratory borings for the building addition and one exploratory boring below the proposed new pavement as shown on Fig. 1. The borings were drilled using a truck-mounted drill rig and continuous-flight auger. Slotted PVC pipe was installed in test holes (TH-1 and TH-2) to ST. PAUL HEALTH CENTER ADDITION TO SANDALWOOD MANOR 3 CTL I T PROJECT NO.ON43,463-125 - - S:1PR0JECTS10N43463.000112512. RePOrtIR103N43463-125 IAOe Hill allow ground water measurements after drilling. A representative of our firm observed drilling, obtained samples and logged the soils encountered. Summary logs of the soils encountered in our borings, field penetration resistance test results, and select laboratory data are presented on Fig 2. The samples were returned to our laboratory for visual verification of field classification and testing. Laboratory testing included moisture content, dry density, swell-consolidation, Atterberg limits, percent fines (passing the No. 200 sieve), and water-soluble sulfate concentration. Laboratory test results are shown on the boring logs (Fig. 2), Figs. 3 through 5, and summarized in Table I. SUBSURFACE CONDITIONS The subsurface conditions encountered inour borings consisted of clayey sands and interlayered clay and sand near the ground surface underlain by sandy clay and then bedrock comprised of claystone, sandstone and interbedded claystone and sandstone at depths of about 17 and 18 feet below the existing ground surface. Pertinent engineering properties of the soils and ground water conditions are presented in the following paragraphs. Sand Clayey sand was encountered near the ground surface in two borings (TH-1 and TH-2) drilled in the area of the addition. The clayey sand was about 6 feet in thickness. The sand was loose to medium dense based on the results of field penetration resistance tests. A clayey sand sample was selected for swell-consolidation test and exhibited 0.1 percent swell after wetting under an applied pressure of 1,000 psf. A clayey sand sample contained 42 percent silt and clay sized particles (passing the No. 200 sieve) with a liquid limit of 28 percent and a plasticity index of 13 percent. We judge the sand to be low swelling or non-expansive. ST. PAUL HEALTH CENTER 4 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463.125 S:IPROJECTSION43463.0001120. Re Gft R1WN43"3.125RLtloC Ir Interlavered Sand and Clay Interlayered clay and sand was encountered at ground surface (S-1) or below the clayey sand and above sandy clay (TH-1 and TH-2). The Interlayered clay and sand was loose to medium dense or stiff based on the results of field penetration resistance tests. Soft, wet soils should be anticipated near the ground water level. One sample was selected for swell-consolidation test and exhibfed 0.6 percent swell after wetting under an applied pressure of 200 psf. Two samples contained 31 and 43 percent silt and clay sized particles (passing the No. 200 sieve) with liquid limits of 23 and 31 percent and plasticity indices of 7 and 18 percent. Sandy Clav Four to nine feet of sandy clay was encountered below the interlayered clay and sand and above the bedrock. The clay was stiff to very stiff based on the results of field penetration resistance tests. Soft, wet soils should be anticipated near the ground water level. A clay sample swelled 0.5 percent after wetting under an applied pressure of 1,000 psf. One clay sample had an unconfined compressive strength of 3,100 psf. Bedrock Bedrock comprised of claystone, sandstone and interbedded claystone and sandstone was encountered in TH-1 and TH-2 below the sandy clay at depths of about 17 and 18 feet below the existing ground surface. The bedrock was medium hard to very hard. Two bedrock samples were selected for swell-consolidation tests and exhibited 0.4 and 1.4 percent swell after wetting under an applied pressure of 1,000 psf. Ground Water Ground waterwas encountered during drilling on February 19, 2008 in test holes TH-1 and TH-2 at depths of 18 and 17.5 feet; respectively. When borings were checked on February 25, 2008, ground waterwas measured intest holes TH-1 and TH-2 at depths of 12 and 10.5 feet or at relative elevations of about 89 and 91.5; respectively. We ST. PAUL HEALTH CENTER ADDITION TO SANDALWOOD MANOR 5 CTL I T PROJECT NO. DN43,463-125 S.IPROJECTSIDN43463.000112512. Rep. ~NRIWN43463-125Ri.EOc IIIII understand the northwest portion of the proposed addition is planned with abasement. The basement floor is planned at a relative elevation of 88 or 90. Ground water will be near or above the proposed basement floor level. Ground water will fluctuate seasonally and yearly and will likely affect the basement construction. Seismicity Based upon the 2006 International BuildingCode (2006 IBC), the site classifies as Site Class D. The subsurface conditions indicate low susceptibility to liquefaction. SITE DEVELOPMENT Demolition Some existing buildings, flatwork and pavements will be demolished for the new construction. We anticipate the soils penetrated by our exploratory borings can be excavated with large excavation equipment such as front end loaders. Removal of large concrete structures may require demolition techniques. All existing building foundation, floor slabs, pavement, trees and landscaping lawn in the addition and new pavement construction areas should be completely removed. Tree roots should be cleared and removed. The resulting excavations should be backfill with moisture conditioned, compacted fill as recommended below in Fill Placement There may be pockets of soft or loose soils at the bottom of the excavation. It may be necessary to stabilize the excavation bottom during construction. We should observe compaction of the backfill after demolition and stabilization of soft soils and perform density tests on fill. Excavation Bracing The stair to the basement will be 10 feet from the existing building. The upper soils are clayey sand. Basement excavation in sand should be sloped at a 1.5 to 1 (horizontal to vertical) slope. We anticipate braced or shored excavations will be necessary for the basement excavation to avoid undermining the existing building ST. PAUL HEALTH CENTER 6 ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463-125 SAPROJECTS10N43463.000112512. Repot %IMN43463-125431.000 1111 foundation. Potential alternatives for braced excavations include soldier piles (piers) and lagging, soil nails and shotcret, continuous drilled piers, or diaphragm walls. Most large excavations in the Denver area are accomplished using soldier piles (steel "H" piles installed in drilled pier shafts) and wood lagging tied back with soil nails. The cost of these methods varies with their complexity. The use of tie-backs must consider influence on adjacent buried utilities and structures. Considering the depth of excavation planned, we believe that bracing can be accomplished using a cantilevered system, tied-back bracing, or soil nail with shot crate facing. The design lateral earth pressures for various earth retaining methods vary. depending upon the type and strength of the soils to be retained, the levels, spacing, and geometry of bracing or tied back to be used, and surcharges adjacent to the excavation. Detailed design and recommendations can be obtained from publications such as "Ground Anchors and Anchored Systems, Geotechnical Engineering Circular No. 4 FHWA-IF-99-015" and "Design Manualfor Permanent Ground Anchor Walls FHWA- RD-97-130" orsimilar documents and various corrputer programs. We believe a design and built approach by a specialty contractor is the most efficient method for the braced excavation. Based on our investigation and subsoil conditions, we have prepared Fig. 6 to provide the apparent pressure envelopes for preliminary bracing design. The earth pressures presented do not include hydrostaticloads or surcharge from traffic. Figure 7 presents methods for evaluation of additional pressure due to surcharge for traffic or footing line loading conditions. Experience indicates that for properly braced excavation in clays andsands the horizontal and vertical movements of the ground may be up to 0.5 percent of the excavation depth. These movements should be considered when designing the bracing. Increasing the tie-back anchor stress and using a more rigid bracing system will reduce the potential movement; however, this will also increase cost. The excavation retention plan should incorporate a monitoring program to document the condition of the adjacent building and include surveying before, during and after construction. ST. PAUL HEALTH CENTER 7 ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463-125 S.-IPROJECTSON43463.000112512. Repotl IRIWN43463.126431.Eoc 11111 We recommend the owner and contractor become familiar with applicable local, State and Federal safety regulations, including the current OSHA Excavation and Trench Safety Standards. Based on our investigation and Occupational Safety and Health Administration (OSHA) standards, we believe the the clay and sand classify as Type C soil. Type C soil requires a maximum temporary slope inclination of 1.5:1 (horizontal to vertical) in dry conditions. Excavation slopes specified by OSHA are dependent upon soil types and ground water conditions encountered. The contractor's "competent person" should identify the soils encountered in the excavation and refer to OSHA standards to determine appropriate slopes. Stockpiles of soils and equipment should not be placed within a horizontal distance equal to one-half the excavation depth, from the edge of excavation. A professional engineer should design excavations deeper than 20 feet. The contractor should be aware that inno case should slope height, inclinations, excavations or depths including utility trench excavations exceed those specified in local, State and Federal safety regulations. Specifically, the current "OSHA Health and Safety Standards for Excavations" should be followed. We understand these regulations are strictly enforced and, if they are not closely followed, the owner, contractor and/or earthwork and utility subcontractors could be liable to substantial financial penalties. Dewatering Basement excavation may encounter ground waterand may require dewatering. Ground water levels are expected to fluctuate; a dewatering drain system should be installed during construction. A drain and permanent dewatering system should be installed for the building basement. We recommend a drain/dewatering system consisting of a continuous layer of clean gravel beneath the floorwith a perimeterdrain trench containing clean gravel and perforated pipe sloping toward a collection sump. The bottom of the trenches should be sloped to provide positive flow. We suggest the minimum slope on the perimeter drains be at least one percent with a similar slope on the bottom of the excavation to direct ST. PAUL HEALTH CENTER ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463-025 S:IPR0JECTSWN43463.00D112=. Repoft1RiU)N4346342&R1Ao0 I!!II flows to the perimeter drain. A minimum of six inches of clean gravel should be provided at the bottom of the slab. A vapor retarder between the slab and gravel layer may be installed depending upon floor finishing considering the ground water is fairly close to the basement floor. Fig. 8 shows a conceptual drain detail beneath the basement floor. A pump should be installed in the sump to remove the collected water. Fill Placement The on-site soils are suitable for use as fill material beneath the building, slabs, and concrete flatwork provided organics, debris and other deleterious materials are substantially removed. If imported fill is necessary it should consist of sand soil with 100 percent passing the 2-inch sieve, 15 to 35percent passing the No. 200 sieve, a liquid limit less than 30 percent, and a plasticity index less than 15 percent. Potential fill materials should be submitted to our office for approval prior to importing to the site. Prior to fill placement, all existing foundation, slabs, pavement, existing fill, demolition debris, organics, tree roots, soft or loose soils, and other deleterious material in the new construction areas should be removed. Areas to receive fill should be scarified to a depth of 8 inches, moisture conditioned to between optimum and 3 percent above optimum moisture content for clay, or within 2 percent of optimum for sand, and compacted to at least 95 percent of standard Proctor maximum dry density (ASTM D 698). Fill and backfill should be placed in thin, loose lifts of 8 inches or less, moisture conditioned and compacted to at least 95 percent of standard Proctor maximum dry density (ASTM D 698). Clay fillshould be moisture conditioned to between optimum and 3 percent above optimum moisture content. Sand fill should be moistened to within ±2 percent of optimum. The placement and compaction of new fill should be observed and tested by a representative of our firm. Even compacted fill and backfill may experience minor settlements. Improvements placedon backfill should be designed for movements of up to 1 percent of the fill depth. ST. PAUL HEALTH CENTER 9 ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463-125 S.1PROJECT=N43463.00D112512. Report IR110N4 463-025-Ri.dm Stabilization of Loose or Soft Soils Loose or soft soils may be encountered near the ground water level in the basement excavation. If loose or soft soils are encountered, they should be removed, re-compacted and stabilized during site preparation. We recommend proof-rolling the foundation soils during site preparation to look for soft soils. If perched water is encountered, we recommend the source of water such as the roof drain of the existing building should discharge or be diverted away from the addition construction area. The surface drainage around the construction area should be improved to slope away from the excavation. The excavation bottom should be sloped to a sump so that water accumulated in the excavation can be collected and removed by pumping. Excessive wetting will result in softening of the foundation soils. If the footing excavation is too small for proof-rolling, we recommend careful observation of the footing excavation. Soft soils should be removed, recompacted or stabilized by crowding 1 to 314 inch crushed rock into the soft soils to reduce settlements of footings and slabs. Sub- excavation to remove the soft soils should not extend. below the existing adjacent footings to avoid undermining of the footings. Soft soils below the footing levels should be stabilized by crowding crushed % or one inch size rock into them until stabilized. A representative of our firm should observe thefooting excavation to assist identification of soft or loose soils. We should also observe removal, compaction and stabilization of soft soils and perform density tests on fill. Utility Construction We recommend the owner and contractor become familiarwith applicable local, state and federal safety regulations, including the current Occupational Safety and Health Administration (OSHA) Excavation and Trench Safety Standards. The contractor's "competent person" should review excavation conditions and refer to OSHA criteria whenever personnel exposure is anticipated. We judge the clay and sand will classify as a Type C soil. Type C soil requires a maximum slope inclination of 1.5:1 (horizontal to vertical) for temporary excavations in dry conditions. Excavating below ground water will require flatter slopes or bracing and ST. PAUL HEALTH CENTER 10 ADDITION TO SANDALWOOD MANOR - CTL I T PROJECT NO. DN43,463.125 SAPROJECT61D1143463.0 0 011 2 512. RepoftWI1DN43453-125R1AOC groundwater control or dewatering. Stockpiles, vehicles and equipment should not be placed within a horizontal distance from the edge of the excavation equal to one-half the excavation depth. Excavations adjacent to and below the existing building should be braced to avoid undermining the foundations and slabs. Water and sewer lines may be constructed beneath pavement, slabs-on-grade and exterior flatwork. Compaction of trench backfill can have a significant effect on the life and serviceability of pavements and slabs. We recommend trench backfill be placed in thin lifts, moisture conditioned, and compacted as recommended above in Fill Placement The placement and compaction of fill and backfill should be observed and tested by a representative of our firm during construction. FOUNDATION Our investigation indicated loose sands and low swelling, stiff to very stiff clay are present at depths likely to affect foundation performance. We were informed that the existing buildings are constructed on footings and are performing satisfactorily. We recommend that the addition be constructed on footings. Design and construction criteria for the foundations are provided below. The footing foundation should be underlain by undisturbed natural soils or well-compacted fill. Where soils are loosened during excavation or in the footing forming process, or if any loose or soft soils are encountered at the footing level, the soils should be removed or compacted to at least 95 percent of standard Proctor maximum dry density(ASTM D 698) and moisture conditioned to within 2 percent of optimum moisture content for sand fill and between optimum and 3 percent above optimum moisture content for clay fill, prior to placing concrete. 2. Footings should be designed`for a maximum allowable soil pressure of 1,500 psf. 3. Wall footings should have a minimum width of 20 inches. Foundations for isolated columns should have minimum dimensions of 24 inches by 24 inches. Larger sizes may be required depending upon the loads and structural system used. ST. PAUL HEALTH CENTER 11 ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463A25 S:IPROJECTSION43463.000112512. Repoft1R1WN43463-02SR1.d00 EEf~ Ir. 4. Grade beams should be well reinforced, top and bottom. We recommend reinforcement sufficient to span an unsupported distance of at least 10 feet or the distance between pads, whichever is greater. Reinforcement should be designed by the structural engineer. 5. Exterior footings must be protected from frost action. Normally, 3 feet of frost cover is assumed in the area. 6. The completed foundation excavation should be observed by a representative of our firm prior to placing the forms to verify subsurface conditions are as anticipated from our borings. 7. To reduce distress between the existing building and the addition, the connections between the addition and existing structure' should be designed to accommodate differential movements of up to 1 inch. 8. Excessive wetting of foundation soils during and after construction can cause softening, settlement or heave of foundation soils and result in footing movements. Proper surface drainage around the building and the addition is critical to control wetting and reduce the risk of foundation movement. FLOOR SYSTEMS AND SLABS-ON-GRADE Our investigation indicates low swelling clay and sand are present near the anticipated floor level. Expansive soil is stable at existing moisture contents but upon wetting or drying can cause heave or settlement of slab-on-grade floors. We estimate potential slab movements of up to 1 inch. Movement of the soil can deform and crack floor slabs and interior partitions. For highly finished floor coverings, such as the or stone, cracking may not be desired. If floor slab movement and associated distress are not desired, a structurally supported floorshould be used. Structural floorsystems are discussed later in the report. If existing fill or soft soils are encountered during construction they should be removed and recompacted as discussed in SITE DEVELOPMENT. A representative from our office should observe the soil conditions after lawn, pavement and flatwork are removed to identify fill and soft soils. The soft soils should be removed or stabilized priorto slab construction. Care must betaken during excavation adjacentto the existing ST. PAUL HEALTH CENTER 12 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 S.TROJECTSI~ N43463.000112M. Repot IR11DN43463425 RIAOC 11111 building to avoid undermining the foundation or causing loss of soil support under the existing floor slabs or concrete flatwork.The basement wall may need to be braced prior to fill compaction. If the owner elects to use slab-on-grade construction and is willing to accept the risk of movement and associated damage, asdiscussed previously, we recommend the following precautions for slab-on-grade constriction at this site. These precautions can help reduce, but will not eliminate damage or distress if slab movement occurs. 1. Slabs in upper, non-basement level should be separated from exterior walls and interior bearing members with a slip joint that allows for free vertical movement of slabs. Basement floor slabs may be tied with foundation and walls if a water-tight basement is planned due to the presence of ground water near the basement level. 2. The 2006 International Building Code - (IBC) or 2006 International Residential Code (IRC) may require a vapor retarder be placed between the base course orsubgrade soils and the concrete slab-on-grade floors. The merits of installation of a vapor retarder below floor slabs depend on the sensitivity of floor coverings and building use to moisture. A properly installed vapor retarder (10 mil minimum) is more beneficial below concrete slab-on-grade floors where floor coverings, painted floor surfaces or products stored on the floorwili be sensitive to moisture. The vapor retarder is most effective whenconcrete is placed directly on top of it. A sand or gravel leveling course should not be placed between the vapor retarder and the floor slab. The placement of concrete on the vapor retarder may increase the risk of shrinkage cracking and curling. Use of concrete with reduced shrinkage characteristics including minimized water content, maximized coarse aggregate content, and reasonably low slump will reduce the risk of shrinkage cracking and curling. Considerations and recommendations for the installation of vapor retarders below concrete slabs are outlined in Section 3.2.3 of the 2003 report of American Concrete Institute (ACI) Committee 302, "Guide for Concrete Floor and Slab Construction (ACI 302.R-96)". 3. The use of slab-bearing partitions should be eliminated. Where such partitions are necessary, a slip joint (orfloat) allowing at least 2 inches of free vertical slab movement should be used. If this "float" is created at the top of partitions, the connection between slab-supported partitions and foundation-supported walls should be detailed to allow differential movement. Doorways and stairs should also be designed for this movement. Sheetrock should not extend to slab-on-grade floors. ST. PAUL HEALTH CENTER 13 ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463-125 SAPROJECTSMN43463.000112512. Report XR11DN43463-126 1.doc 4. Underslab plumbing should be eliminated, if possible. Where such plumbing is unavoidable, it should be thoroughly pressure tested for leaks before the slab is constructed and should be provided with flexible couplings. Gas and water lines leading to slab-supported appliances should be constructed with flexibility to accommodate up to 2 inches of movement. 5. Plumbing and utilities which pass through slabs should be isolated from the slabs. 6. If HVAC equipment is supported on slab-on-grade floors, collapsible connections allowing 2 inches of movement should be provided between the equipment and associated ductwork. 7. Exteriorslabs including entryways orwalkways should be isolated from the foundations. These slabs should be well reinforced to function as independent units and designed to prevent distress to foundations in the event of soil movement. 8. Frequent control joints or reinforcement should be provided in all slabs to reduce problems associated with shrinkage, in accordance with American Concrete Institute (ACI) or PICA criteria. We advocate an additional joint 3 feet away from and parallel to foundation walls. Structural Floors The owner must accept the risk of floor movement or a structurally supported floorshould be provided. Structural floors canalso be considered for specific areas that are particularly sensitive to movement such as entries, bathroom and kitchen areas, with tile floor or stone covering. For structurally supported floors, we recommend a minimum void between the ground surface and the underside of the floor system of 8 inches. This void space applies to non-wooden structural floors (steel joists supporting steel decking and a concrete topping slab). The minimum clearspace provided should be constructed below beams and utilities that penetrate the floor. For wooden structural floors, building code requires a minimum clearance of 18 inches between bottom of floorjoist, and exposed ground surface. We suggest increasing the air space to at least 20 inches at this site to allow for some heave of the subsoils under the floors, where untreated wood floor ST. PAUL HEALTH CENTER _ 14 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 S.XPROJECTSWN43 3.000112512. Reporta1R11DN43463425i11AOO IHil components are used and the ground surface is exposed. Where other floor support materials are used, a minimum clear space of 8 inches should be maintained for this site. This minimum clear space should be maintained between any point on the underside of the floor system (including beams, plumbing pipes, and floor drain traps) and the surface of the exposed earth. Where structurally supported floors are used, utility connections, including water, gas, air duct and exhaust stack connections to floor supported appliances, should be capable of absorbing some deflection of the floor. Plumbing that passes through the floor should ideally be hung from the underside of the structural floor and not laid on the bottom of the excavation. This configuration may not be achievable for some parts of the installation. It is prudent to maintain the minimum clear space below all plumbing lines. Control of humidity in crawl spaces below the structural floors is important for indoor air quality and performance of wood floor systems. Our scope for this project did not include providing recommendations to control humidity. Nevertheless, since we are involved in this type of work we feel we should comment. We believe the best current practices to control humidity involve the use of a vapor retarder (10 mil minimum), placed on the exposed soils below accessible sub-floor areas. The vapor retarder should be sealed at joints and attached to concrete foundation elements. The foundation drain details in this report include a vapor retarder. If desired, we can provide designs forventilation systems that can be installed in association with a vapor retarder, to improve control of humidity in crawl space areas. The Moisture Management Task Force of Metro Denver' has compiled additional discussion and recommendations regarding current best practices for the control of humidity in crawl spaces. ""Guideline for Design ad construction of New Homes with Below-Grade Under-Floor Spaces", Moisture Management Task Force, October 30, 2003. ST. PAUL HEALTH CENTER 15 ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO. DN43,463-125 SnPROJECTSV)N43463.000112512. RepodsiRlID1,143463-125-RI doc 11111 BELOW-GRADE CONSTRUCTION Basement and/or foundation walls and grade beams that extend below grade should be designed for lateral earth pressures where backfill is not present to about the same extent on both sides of the wall. Many factors affect the value of the design lateral earth pressure. These factors include, but are not limited to, the type, compaction, slope and drainage of the backfill, and the rigidity of the wall against rotation and deflection. For a very rigid wall where negligible or very little deflection will, occur, an "at-rest" lateral earth pressure should be used in design. If on-site soils are used as backfill and the backfill is not saturated, we recommend design of basement walls at this site using an equivalent fluid density of at least 60 pcf. The structural engineer should also consider site specific grade restrictions and the effects of large openings on the behavior of the walls. Ground water is close to basement floor level. Seasonal rise of ground water may result in water in the basement. The basement may be constructed as a water-tight structure and/or a permanent dewatering system should be installed. To reduce the likelihood water pressure will develop outside foundation walls and the risk of accumulation of water at basement level, werecommend provision of a foundation drain around the entire basement perimeter. The drain should consist of a 4-inch diameter open joint or slotted pipe encased in free-draining gravel. The drain should lead to a positive gravity outlet, such as a sump where water can be removed by pumping. Typical foundation drain details are presented on Fig. 8. A six-inch clean drain gravel layer should be installed below the basement floor slabs to collect water during high ground water seasons and break the capillary rise of moisture. The provision of a drain will not eliminate slab movement. The sump pump should be well maintained and regularly checked. Breakdown of the sump pump could cause basement flooding and damages. An alarm system in the sump pit to warn potential basement flooding should be installed. ST. PAUL HEALTH CENTER 16 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 S:I3ROJECTSIDN43463.0 0 011 2 51 2. RBporta 11DN43463-125R1.Coc EEffff F_: !!!II PAVEMENTS Subgrade soils were investigated by drilling one exploratory boring (S-1) to a depth of 5 feet at the location shown on Fig. 1. Subsoils encountered in our boring consisted of interlayered sandy clay and clayey sand. Laboratory testing was designed to provide index properties of the soilssampled and subgrade support values for those soil types that influence the pavement design. To evaluate potential heave, swell- consolidation testing was performed on one sample at from a depth of four feet. The sample exhibited 0.6 percent swell after wetting under an applied pressure of 200 psf. A bulk sample of the interlayered sandy clay and clayey sand contained 43 percent fines (.200) with a liquid limit of 31 percent and a plasticity index of 18 percent. Using the American Association of State Highway Transportation Officials (AASHTO) system, the sample was classified as A-6 with a Group Index of 4. Based on the Group Index of 4, we have estimated a CBR value of 3.5 for pavement soil support. We anticipate the pavement areas will be subjected to automobile loads in the parking stalls and occasional truck traffic inaccess drives and near the trash collection areas. The primary considerations when selecing pavement alternatives will notjust be the pavement section; long-term maintenance and performance considerations will govern. We assumed the following minimum traffic volumes: Equivalent Daily Load Application (EDLA) of 5 for automobile parking and EDLA of 30 for fire lanes and drive areas subject to truck traffic. Based on the Colorado Department of Transportation (CDOT) pavement design, we have prepared Table A below for the pavement recommendations. TABLE A ST. PAUL HEALTH CENTER - - 17 ADDITION TO SANDALWOOD MANOR - CTL [ T PROJECT NO. DN43,463-125 SAPRDJECTSIDN43463.0DM12512. RepoNSR2110N43463-12s 1.noe IHil Our experience indicates problems with asphalt pavements can occur where heavy trucks drive into loading and unloading zonesand turn at low speeds. In areas of concentrated loading and turning movements by heavy trucks, such as at entrances, loading docks, and trash.collection areas, we recommend Portland cement concrete pavement. We recommend installing minimum6-inch thick concrete pads at loading and dumpster areas, sufficient in size to support the entire truck. The design of a pavement system is as much a function of paving materials as supporting characteristics of the subgrade. The quality of each construction material is reflected by the strength coefficient used in the calculations. If the pavement system is constructed of inferior material, then the life and serviceability of the pavement will be substantially reduced. Materials and placement methods should conform to the requirements of CDOT or the City of Wheat Ridge. All materials planned for construction should be tested to confirm their compliance with project specifications. The structural coefficient assumed for the aggregate base course in our evaluation is an R-Value of 77. A CDOT Class 5 or Class 6 base course or recycled concrete material that meets the Class 5 or 6 designation should meet these requirements. Base course quality varies considerably and can be sensitive to change in moisture; therefore, we recommend the material planned for base course be laboratory tested prior to importing it to the site. Control joints should separate concrete pavements into panels as recommended by the American Concrete Institute (ACI). No de-icing salts should be used on paving concrete for at least one year after placement. Routine maintenance, such as sealing and repair of cracks and overlays at 5 to 7-year intervals, are necessary to achieve long- term performance of an asphalt system. We recommend application of a rejuvenating sealant such as fog seal after the first year. Deferring maintenance usually results in accelerated deterioration of pavements leading to higher future maintenance costs. Construction guidelines for flexible and rigid pavement are shown in Appendix A. ST. PAUL HEALTH CENTER 18 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 S4PROJECTMDN43463.000112512. R¢PGMs R11DN43463-125 1.doc H A primary cause of early pavement deterioration is water infiltration into the pavement system. The addition of moisture usually results in softening of the subgrade and eventual failure of the pavement. We recommend drainage be designed for rapid removal of surface runoff. Curb and gutter should be backfilled and the backfill compacted to reduce ponding adjacent to the pavements. Final grading of the subgrade should be carefully controlled so that design cross-slope is maintained and low spots in the subgrade which could trap water are eliminated. Seals should be provided between curb and pavement and at all joints to reduce moisture infiltration. Landscaped areas and detention ponds in pavements should be avoided. A grease trap storm and water quality vault will be buried under the pavement. These structures should have adequate strength to support the pavement traffic loads. The backfill of the excavations around these structures should be compacted as recommended in Fill Placement For narrow space backfill where compaction is not feasible, flow fill may be used. SURFACE DRAINAGE Performance of floor slabs, flatwork and foundations is influenced by changes in subgrade moisture conditions. Carefully planned and maintained surface grading can reduce the risk of wetting of the foundation soils. We recommend the following precautions be observed during construction and maintained after construction is completed: 1. Wetting or drying of the foundation excavations should be avoided. Excessive wetting of foundation soils and pavement subgrade before, during, and after construction can cause softening, compression or swell of subsoils and result in foundation, slab and pavement movement and distress. 2. Positive drainage should be provided away from the existing and proposed buildings. We recommend a minimum slope of at least 10 percent in the first 5 to 10 feet away from the foundations in landscaped areas, where possible. Pavements and sidewalks adjacent to the buildings should be sloped for positive drainage away from the foundations. A minimum slope of 2 percent is suggested; more slope is desirable. Water should not be allowed to pond on pavements. ST. PAUL HEALTH CENTER 19 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 S.IPROJECTSWN43463.000112M. RBpoft)R10N43463-125-R4.d0C HIII 3. Backfill around foundation walls and grade beams should be moisture treated and compacted as discussed in Fill Placement. 4. Roof drains should be improved to direct away from the buildings and addition. Downspout extensions and splash blocks should be provided at discharge points. Where downspouts discharge onto pavements or flatwork, they should be sloped away from the structures, as discussed above. If roof discharge is piped below slabs orflatwork, the pipes should be non-perforated, not leaking and glued atjoints. The drain pipes should be thoroughly pressure tested for leaks; any leaks should be repaired before placing slabs or backfill. The drain pipes should be connected to positive gravity outlets or discharge points. 5. Landscaping should be carefully designed to minimize irrigation. Irrigation should not be located within 5 feet of foundations. Sprinklers should not discharge within 5 feet of foundations. Irrigation should be limited to the minimum amount sufficient to maintain vegetation; application of more water will increase likelihood of slab and foundation movements. 6. Impervious plastic membranes should not be used to cover the ground surface immediately surrounding the addition. These membranes tend to trap moisture and prevent normal evaporation from occurring. Geotextile fabrics can be used to limit weed growth and allow for evaporation. CONCRETE Concrete in contact with soil can be subject to sulfate attack. We measured water-soluble sulfate concentrations of 0.009 in a sample from this site. Sulfate concentrations less than 0.1 percent indicate Class 0 exposure to sulfate attack for concrete in contact with the subsoils, according to the American Concrete Institute (ACI) Guide To Durable Concrete (AC1201.2R-01) Forthis level of sulfate concentration, ACI indicates any type of cement can be used for concrete in contactwith the subsoils. In our experience, superficial damage may occur to the exposed surfaces of highly permeable concrete, even though sulfate levels are relatively low. To control this risk and to resist freeze-thaw deterioration, the water-to-cementitious material ratio should not exceed 0.50 for concrete in contact with soils that are likely to stay moist due to surface drainage or high water tables. Concrete should have a total air content of 69/6± 1.5%. We recommend all walls in contact with the subsoils be damp-proofed. ST. PAUL HEALTH CENTER 20 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43A63-025 S:IPROJECTSWN43463.000112512. Repo bIRi WN43463425421.EOc LIMITATIONS Three borings were drilled to obtain a general picture of foundation soil conditions under areas of the proposed addition and new surface parking. The borings are representative of conditions encountered only at the exact boring locations. Variations in the subsoil conditions not indicated by our borings should be anticipated. A representative of our firm should observe demolition, foundation excavations, footings, basement foundation drain, pavement construction and observe and test placement of fill. We believe this investigation was conducted with that level of skill and care normally used by geotechnicai engineers practicing in this area at this time. No warranty, express or implied, is made. If we can be of further service in discussing the contents of this report or in the analysis of the influence of subsoil conditions on design of the structures, please call. CTLITH t 14- nnA-Pin Principal NPHJnphlnt (5 copies) cc via e-mail: ioan(&mha.bz jpeis l ey(& mbcdenve r.co m cc: McGlamery Structural Group 3734 Osage Street Denver, Colorado 80211 Attention: Mr. Sam McGlamery ST, PAUL HEALTH CENTER 21 ADDITION TO SANDALWOOD MANOR CTL T PROJECT NO.ON43,4S3.125 SaPROJECT5IDN4]d6]D60`d2S@. Rapar{siRRORG1M3t2SRt.tlot LcGENU: W. 44TH AVE. TH-1 INDICATES APPROXIMATE LOCATION OF EXPLORATORY j BORING m S-1 INDICATES APPROXIMATE W. 39T 0 30 eb O LOCATION OF SUBGRADE a d SAMPLE SCALE: t' - 60' 3~: m TBM TEMPORARY BENCHMARK: a 4 SLAB AT EAST MAIN ENTRANCE < < (ASSUMED ELEV.=100.0') z INDICATES EXISTING BUILDING TO _ BE DEMOLISHED FOR NEW CONSTRUCTION 1 I EXISTING ! BUILDING ! ! .J ! ! ! EXISTING ! ! ! COURTYARD! ! ! ! ! PROPOSED ----I BFE=88 COURTYARD j ! OR 0 -1 0 ! ! PROPOSED ! ADDITION ~ ST FLOOR = 90; ! ! C WEST 38TH AVENUE ST. PAUL HEALTH CENTER AODMON TO SANDALWOOD MANOR Project No. DN43,463-125 W. 38TH Al/E. IF VICINITY MAP NOTTO SCALE S-1 TBM Locations of Exploratory Borings n W fr Z d i Fig. 1 2 J 0 u j G U ~ n Z J O J _ L CyCI -C z n o~ C S K N: z j <D a G 6 ~ J 1 c 2 YD C J S O 2 2 N 6G i~ n 3J } ~ C i o ~ ~ ~ Y y 'ZISJ nh rc J4 +fC nw SC C ~ iC G L _ J J ~ 2 D Z , G~ 01 f IJJ Y> ~ Y J a -~S yi ~ !G' J ~i WN G > O K J C7 uP~K N~ n i~L~L~1 J N O N Q 7 > Z „ Qi• L N 2✓ Gr C > r: ~ ZC' G M F Z Z 3 ~ . 13 v O~ W ~~a o ~ S rtu u+ ' ~ i ' ' 1 E L . v 3 Z G 9Q ^h s i n N 4 oz W ~r U p 2?~'vE0 UW" F ~ O L 2 4 = 4 _ ~ ~F O GU ~ 5,?ZZO ~ ~ + CZ~ t C ] u "I = J N ' . CMG OU' C W ~ j ~vl G W L JN.NA Yr V WN~ K -r f a ' ` . z f LL n +J G 'C 22222 G._00 'JV W i w 0.z V .LL as LL< ~ N i u. m n G C K . 4.. n ~ Jt^ FJ q n } ELM Z n ~ y V N Z O m i= J W u4~ c.t 3 2 z 0 co z a0 x LU a z + 0 65 W ~ -z a 0 0 0 -3 Ana 1.0 10 100 EXPANSION UNDER WETTING PRESSURE DUE TO T{} WETTING 1 APPLIED PRESSURE - KSF Sampic^ Of SAND, CLAYEY (SC) SAMPLE DRY UNIT WEIGHT= 111 PCF From TH-1 AT 4 FEET SAMPLE MOISTURE CONTENT= 1$.3 % 3 2 z 0 V) Z t a w 0 a O -1 W IL fl -2 U EXPANSION UNDER CONSTANT PRESSURE DUE TO (NETTING . 0.": 1.0 10 .00 APPLIED PRESSURE - KSF Sample Of 'INTERBEDDEDCLAYSIONEISANDSTONE SAMPLE DRY UNIT WEIGHT= 33 PCF From TH-1 AT 24 FEET SAMPLE MOISTURE CONTENT= 35.5 % Swell Consolidation ST. PAUL HEALTH CENTER ADDIT IONTO SANDALWOOD MANOR - Test Results FIG.3 PROJECT NO. D1443 ,4G.1-1Z5 SM1'~i:GJELTSIDNA34'u3AC'J1t2517.4ep.: s.Ri:^„m'3453 si(.14 -3 3 Z i O U5 Z 0 LU w e 0 -7 m W UJ -2 CL CL n 0 IJ -3 4 2 T EXPANSION UNDER C ING PRESSURE DUE TO WETTING 10 APPLIED PRESSURE -KSF Somple of CLAY, SANDY (CL) SAMPLE DRY UNIT WEIGHT= 95 PDF rom TH-2 AT 18 FEET SAMPLE MOISTURE CONTENT= 31A % 3 2 z a to z a a x ua 0 0 to to 1 D1 iY a 0 2 0 EXPANSION UNDER CONSTANT PRESSURE DUE TO WETTING 4 100 0.i 1.0 t0 APPLIED PRESSURE - KSF Sampl-- Of CLAYSTONE SAMPLE DRY UNIT WEIGHT= 102 PCF From TH-2 AT 19 FEET SAMPLE MOISTURE CONTENT= 22.$ % Swell Consolidation ST. PAUL HEN TH CENTER ADDITIONTO SANDALWOOD MANOR Test Results FIG.A PROJECT NO. DN43,493--725 S;,Ph?32GTS~N&3p63.96T'1251:. Rapc2slR C'.dni3•~fiadxasi(s:,a:ft 7 4 3 z 0 N Z M X w Z 0 0 in w rr -1 IL 2 0 v -2 EXPANSION UNDER CONSTANT PRESSURE DUE TO WETTING 0.7 ?.7i is APPLIED PRESSURE - KSF Sample of INTERLAYERED CLAYISAND SAMPLE DRY UNIT WEIGHT= rom S-1 AT 4 FEET SAMPLE MOISTURE CONTENT= ST. PAUL HEALTH CENTER ADDITION TO SANDALWOOD MANOR PROJECT NO- DN43.463-125 S'3'RfJJECTS;JNa2163 9IXY.92S.2. Ae~wttsJt?W?CSt63.t25,x~{ewe:l 4 s 6 .7 108 PCF 74'.7 % 100 Swell Consolidation Test Results FIG.5 EARTH PRESSURE CANTILEVER WALL LJ P = 27H psf BRACED OR TIE-BACK EXCAVATION h: h P = 40He psf He =h t 1/2 h, CANTILEVER WALL-SLOPING BACKFILL P = 60H Dsf P BASEMENT WALL ST. PAUL HEALTH CENTER AMMON TO SANDALWOOD MANOR Project No. DV43,463-125 P = 40H psf Recommended Lateral Earth Pressure Distribution Fig. 6 WALL TYPE W = TOTAL WEIGHT OF TRUCK L = LENGTH OF LOAD PARALLEL TO THE EXCAVATION X = DISTANCE FROM THE EDGE OF THE EXCAVATION H = TOTAL DEPTH OF EXCAVATION q LINE LOAD PER LINEAL FOOT W q = L ffh = LOAD AT DEPTH h DUE TO LINE LOAD q FOR m ! 0.4 _ 1.2Bq m'n 71 2 6h H [m +n FOR m 5 0.4 ~h= 02n 7 [0.18+n?] SURCHARGE DUE TO TRAFFIC OR LINE LOADS ON RIGID WALL ST. PAUL HEALTH CENTER ADOMON TO SANDALWOOD MANOR Project No. DN43,463-125 Surcharge Lads Fig.7 T s , G - 0R rILL__) SLOPE PER OSHA FOOTING OR PAD SEE NOT 2 ENCASE PIPE IN 1/2" TO 3/4" WASHED GRAVEL. EXTEND GRAVEL LATERALLY TO FOOTING AND PROVIDE AT LEAST 4 INCHES OF GRAVEL BELOW FLOOR SLAB. BELOW-GRADE WALL SLIP JOINT OR TIED TO WALL OR FOOTING IF WATER-TIGHT BASEMENT IS PLANNED SLAB-ON-GRADE=:::_;:%:... 6" MIN. B" MIN. OR BEYOND 1:1 SLOPE FROM BOTTOM OF FOOTING (WHICHEVER IS GREATER) 10 MIL VAPOR RETARDER MAY BE INSTALLED DEPENDING UPON FLOOR FINISHING. 4-INCH DIAMETER PERFORATED DRAIN PIPE. THE PIPE SHOULD BE PLACED IN A TRENCH WITH A SLOPE OF AT LEAST 1/8-INCH DROP PER FOOT OF DRAIN. NOTES: 1) THE BOTTOM OF THE DRAIN SHOULD BE AT LEAST 12 INCHES BELOW BOTTOM OF SLAB AT THE HIGHEST POINT AND SLOPE DOWNWARD TO A POSITIVE GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPING. 2) FOR CONTINUOUS FOOTINGS, WE RECOMMEND PLACING A 4-INCH THICK, S-INCH WIDE SECTION OF VOID FORM PERPENDICULAR TO FOOTING LINE ABOUT EVERY 10 TO 15 FEET AND AT WINDOW WELLS, TO ALLOW WATER IN WALL SACKFILL TD PASS BENEATH THE FOOTING INTO THE INTERIOR DRAIN. THIS CAN ALSO BE ACCOMPLISHED BY "TUNNELING" UNDER FOOTINGS AT THE TIME OF DRAIN -INSTALLATION. THIS DETAIL SHOULD BE REVIEWED BY THE STRUCTURAL ENGINEER DURING FOUNDATION DESIGN AND INCORPORATED INTO THE FOUNDATION PLAN. ST. PAUL HEALTH CENTER ADDRION TO SANDALWOOD MANOR Project No. C.1N43,463-125 Interior FwundatiQn Vliell Drain Fig. 8 J N Li N W } 6 W ~ J ~ G 31. 4 r s a N J Q d wD^ Z"JC W =ZZ K Z C W-Z Z SOU K ~ N¢c W a llill APPENDIX A FLEXIBLE AND RIGID PAVEMENT CONSTRUCTION RECOMMENDATIONS ST. PAUL HEALTH CENTER ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-725 S1PRO3EC VN43463.WMIM.ReponsV1OM3463-12SRl.d. 11111 FLEXIBLE PAVEMENT CONSTRUCTION RECOMMENDATIONS Experience has shown that construction methods can have a significant effect on the life and serviceability of a pavement system. We recommend the proposed pavement be constructed in the following manner: The subgrade soils should be stripped of organic matter, scarified, moisture treated, and compacted. We recommend the top 1-foot of the subgrade be moisture conditioned and compacted to at least 95 percent of standard Proctor maximum dry density (ASTM D 698, AASHTO T 99). Clay subgrade should be moisture conditioned between 0 and 3 percent above optimum moisture content. Granular subgrade should be moisture conditioned to within 2 percent of optimum moisture content. The subgrade should be kept moist prior to paving. 2. Utility trenches and subsequently placed fill should be properly compacted and tested prior to paving. Fill should be compacted as outlined above. 3. After final subgrade elevation has been reached and the subgrade compacted, the area should be proof-rolled with a heavy, pneumatic- tired vehicle (e.g. a loaded ten-wheel dump truck). Subgrade that is pumping or deforming excessively (about 1-inch) should be scarified, moisture conditioned and compacted. Asphalt should not be placed on soft, wet, frozen, or otherwise unsuitable subgrade. 4. Asphaltic concrete should be hot plant-mixed material compacted to at least 95 percent of maximum Marshall density. The temperature at laydown time should be near 235 degrees Fahrenheit. The maximum compacted lift should be 3 inches and joints should be staggered. 5. The subgrade preparation and the placement and compaction of pavement material should be observed and tested by a representative of our firm. Compaction criteria should be met prior to the placement of the next paving lift. Additional requirements of The City of Wheat Ridge or the Colorado Department of Transportation (CDOT) Specifications should apply. ST. PAUL HEALTH CENTER A-1 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 S.IPROJECTSIDN43453.0 0 0 11 2 512. Repoft1R11DN43463-12S-R1.doc RIGID PAVEMENT CONSTRUCTION RECOMMENDATIONS Rigid pavement sections are not as sensitive to subgrade support characteristics as flexible pavement. Due to the strength of the concrete, wheel loads from traffic are distributed over a large area and the resulting subgrade stresses are relatively low. The critical factors affecting the performance of a rigid pavement are the strength and quality of the concrete, and the uniformity of the subgrade. We recommend subgrade preparation and construction of the rigid pavement section be completed in accordance with the following recommendations: The subgrade soils should be stripped of organic matter, scarified, moisture treated, and compacted. We recommend the top 1-foot of the subgrade be moisture conditioned and compacted to at least 95 percent of standard Proctor maximum dry density (ASTM D 698, AASHTO T 99). Clay subgrade should be moisture conditioned between 0 and 3 percent above optimum moisture content. Granular subgrade should be moisture conditioned to within 2 percent of optimum moisture content. The subgrade should be kept moist prior to paving. 2. After final subgrade elevation has been reached and the subgrade compacted, the area should be proof-rolled with a heavy, pneumatic- tired vehicle (e.g. a loaded ten-wheel dump truck). Subgrade that is pumping or deforming excessively (about 1-inch) should be scarified, moisture conditioned and compacted. Concrete should not be placed on soft, wet, frozen, or otherwise unsuitable subgrade. 3. Curing procedures should protect the concrete against moisture loss, rapid temperature change, freezing, and mechanical injury for at least three days after placement. Traffic should not be allowed on the pavement for at least one week. 4. A white, liquid membrane curing compound, applied according to the manufacturer's recommendations, should be used. 5. Construction joints, including longitudinal joints and transverse joints, should be formed during construction or should be sawed shortly after the concrete has begun to set, but priorto uncontrolled cracking. Joints should be sealed. ST. PAUL HEALTH CENTER A-2 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125- S:TRQIECTSDN43463.000%12M.Report MIDN43461126R1.00c Ilill 6. Construction control and observation should be carried out during the subgrade preparation and paving procedures. Concrete should be carefully monitored for quality control. Additional requirements of the City of Wheat Ridge or Colorado Department of Transportation (CDOT) Specifications should apply. The design section is based upon a 20-year period. Experience in the area indicates virtually no maintenance or overlays are necessary for the design period. We believe some maintenance and sealing of concrete joints will help pavement performance by helping to keep surface moisture from wetting and softening subgrade. To avoid problems associated with scaling and to continue strength gain, we recommend deicing salts not be used for the first year after placement. ST. PAUL HEALTH CENTER A-3 ADDITION TO SANDALWOOD MANOR CTL I T PROJECT NO. DN43,463-125 _ SAPROJECTSIDN43463.000112512. RepoN %R11DN43468-125-Rt.dm - --.r .F.. a -;;-3 ;-r r Wiz.., CITY OF WHEAT RIDGE Building Inspection Division , (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 235-2857 Fax INSPECTION NOTICE / Inspection Type: s~pGnter~>.vn Plote%. Job Address/Permit Number: 397s A6914z sr. r: d~ SSG tr1` aF 61st 4640AA4, ~/JY.a/ lri6J1 aVS.~S.2 1£~ ~sT.ea/li /$t ~7~ .LSs~}'/.sr/~ ❑ No one available for inspection: Time AM/PM Re-Inspection required: "Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: 4-ti ~ 5? Inspector: Ta DO NOT REMOVE THIS NOTICE ~u... ~ City of Wheat Ridge Commercial Demolitio PERMIT - 081004 PERMIT NO, JOB ADDRESS, DESCRIPTION, 081004 3835 HARLAN ST Demo part of existing building ISSUED, EXPIRES, 09/02/2008 03/01/2009 *** CONTACTS *** owner gc 303/329-8003 Thomas Cella Sandalwood Manor 08-0173 Spectrum General Contractors ** PARCEL INFO ** ZONE CODE, UA SUBDIVISION, UA USE, BLOCK/LOT#, UA 0/ Demolition Fee ** TOTAL ** ESTIMATED FEES 50.00 50.00 PROJECT VALUATION, .00 ** FEE SUMMARY ** If~~EjJ Comments: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have 'read and agree to abide by all conditions print~d'on this application and that I assume full responsibility for complianC,e0ith the Wheat Ri~e Building Code (I.B.C) and a'fl other applic 1 Wheat Ordinances, for work under this permit. PI ns subject to field inspecti9n. . ' 1. This permit was issued in accordance with the provisions set forth in your application and is subject to ~he laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications ,and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review ield inspections. date INSPECTION REQUID LINE: REQUESTS MUST BE MADE BY (303)234-5933 BUILDING OFFICE, (303)235-2855 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. -ILY VI 1I'1I'In:;0\. I'\.I\.I~'G J.JLI"UII'~ I,.J'V,.;:t,VII 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Inspection Line: 303-234-5933 aate: 0 q .0:;;;' , O'g Plan#: Permit #: 08" 100+ Building Permit Application Property Address ,?B'3? HA-[Ll..Ai'J Property Owner (please print): 5A->v P4L N-oOc{ /14-\[0 IL LJ...-L Mailing Address: (if different than property address) Phone: Address: City, State, Zip W~~ CoLo Contractor Sf)....e.+~ G - C . Contractor License #: 0 g ~ () I ( ~ Phone: 30'S' ~L..-'1.. 80e 3 Sub Contractors: Electrical City License #: Company: Plumbing City License #: Company Mechanical City License #: Company: Exp. Date: Approval: Exp. Date: Approval: Exp. Date: Approval: Construction Value: $ (as calcufated per the Building Valuation Data sheet) Use of space (description): DescriPtion~~f-c.:M./ YM.-t. fJ{. px:lst-VVq Sq. F\.IL.Ft added: Squares BTU's Gallons Plan Review (due at time of submittal): $ Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.8.C) and all other applicable Wheat Ridge Ordinances, for work under this pennit. Plans subject to field inspection. CfRLCE ONE:: PRINT NAME: (OWNER) (CONTRACTOR) or PERSONALREPRESEN~f(O~CONTRATOR) 0 -.11-1oM.f.I<S c..r--U..A- SIGNATURE: "C<. Date: 7~ (J,;/ DEPARTMENT USE ONLY ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: FIRE DEPARTMENT:: 0 approved wI comments 0 disapproved 0 no review required I Bldg Valuation: $ OCCUPANCY: . Colorado Department of Public Health and Environment Air Pollution Control Division - Indoor Environment Program - Asbestos/IAQ Air Unit 4300 Cherry CreekDrive South, APCD-IE-B1 Denver, Colorado 80246-1530 Phone: 303-692-3100 - Fax: 303-782-0278 E-mail: asbestos@state.co.us DEMOLITION.2ftlPll~~;AL NOTICE A', ...._,.. -.. ..~ ' .. ....,.~~.'.:::-.-":.'..-.. This approval notice is granted subject to ColQrado Air Quality Con.il:l'lLCommission Regulation No.8, Part B, adopted December 21, 2007, and effective Janu~ry 30, 20.GB and the Colorado Air _ Pollution Prevention and Control Act C.R.S. (25-7-101 anq..25c7-50 1 et s~V. This notice signifies that the structure was inspected for asbestos, lumm0usexir."li~s (eenta. . . . radioactive material), and Ozone-Depleting Refrigerants and the d~m6JitiQn>cQllt!:-a~t0r has ,!?f0p notified the Colorado Department of Public Health andEnvir-oITm.entpJ1Tf;uantto\:~egul n No.8, Part B. ,.. "-.""'-- . - . As [contractor, youmap15e $].rPj~~'1o other demolition licell~es ~~:\P~~i~~.;idepenlling on the requirements of the county and municipality in which the work is being perf~Jtmed. The Colorado Department of Public Health and Envirol1111ent, Air l.'t)lll}tiQl1Cont~oJDivi$:i,wn, strongly suggests that you check with county.and munieipal al}tl1Q~.iti~$:ln'o.ljd~r tq:!if~te~i%~il:july other local building/permitting requireIr).entsthatliIUSI berner:' .' ..... ,,_: _....... .". '.:_ ....._ "',', ,'_" ."C"'.,' ..'.... -..,..... .. .___.<>.....>. ..... _:.:t:'")::,, .. .. '--,'.. "".->' .,>':.':.....,.:....,.,.-..,..--":-..,: :......,.'.:.,'....::...':'...... ....'.-----.::. .:.,.:.:.'--.~.;.....- Please note that certain asbes~ds"contll.inii1gRill.te~illis(AC~>~~~;emain in the structure during demolition. Therefore, anY;~.!.\lJ:lulition debrisJ~f~!.l~\l:i;jfd after the completion of post- demolition site cleanup may constitute..a"'I,'~$1~~!!->t~t~p:w:.0f asbestos-contaminated soil" at the site, subject to the requirements of Section S;Saf the Solid Waste Regulations (6 CCR 1007-2, Part 1). THE ORIGINAL APPROVAL NOTICE MUST BE POSTED ON SITE AT ALL TIMES. Immediately notify the AsbestoslIAQ Unit of project modifications by fox (number above) or e-mail (address above) and the appropriate county health department by fax. Project modifications include changes in the scope of work or the scheduled work dates, etc. This demolition approval notice is valid beginning 7/9/2008. . The actuaLscheduled wurk..dates.are.from 7/9.,12OO.S ...through. 8I9/zoQ8.-.... Approval issued on: 6/27/2008 Record number: 62763 Notice Number: 08JE2369D Fee Paid: $60.00 Check number: 33865 For the location specified below: Sandelwood Manor Asbestos Building Inspector: Chris Maron Cerification No.; 615 3835 Harlan St. Wheat Ridge Jefferson County This notice has been issued to: Hillen Corporation 7600 Dahlia St. Commerce City, CO 80022 Inspection Date: 06/16/2008 Issued by: RWJ ~ DEMOLlTION NOTIFICATION APPLICATION FORM APPLICATION FEE MUST ACCOMPANY THIS FORM I NCQMI?,LETE APPLlCATIQNS WILL BE RETURNED (Notice will be mailed to the demolition contractor unless specified otherwise) Fee: $50 + $5 per 1000 If of area to be demolished :;i~{.~O. ~ (See instruction #1 on reverse side) . -,. -, ,- Submit form to: Pennit Coordinator Colorado Dept. of Public Health and Environment APCD-IE.B1 4300 Cherry Creek Drive Sou1h Denver, CO 80246-1530 Phone: 303-692-3100 Fax: 303.782-0278 Asbestos@state.co.us Colorado Department of Public Health and Environment '" o t) E - e o o e o :2 "0 E .. c '" '" - 0 0"- ->.., '" 0 .. .. E '" .cCl)e '" a: 0 <( 0 '" ~ .. Q. '" .Ee ",.S! .21ii "'.., .."" .c .- ",1:: <(.. -00 .. "" 'E .. o '" ",'"0 co- ._ ... U -0.... =c:b '" ~ e lIlOO o Company Name: Hillen Co oration Building~me: ~ l ~(!.-'\t'\.de- IA./cod <\ 0 Square fOQtage of footprint of facility or portion of facility to be demolished 1:$ ~ (northeast win be innin at the fIrewall) street Street Zip Code: City: Zip Code: Commerce Ci 80022 Telephone # Fax # (303) 287-2664 (303) 287-1663 Project Manager. Cell Phone # Rick Cowell (303) 877-9718 I certify that the Certified Asbestos Building Inspector has informed me about any remaining asbestos-containing materials in. the facility to be demolished. .. - en , e o :e "0 E .. c t8I Wrecking 0 BUmingt_D Implosion 0 Moving 0 Other, specify: clU- l~~d~ILReceiving Building A--:',E t Burning requires additional authorization - Please call (303) 692.3100 and ask to 5 eak to the 0 en Bumln Permit Coordinator ': ~ Owner's Name: .. e Total Quantity of Asbestos Removed ~ Street: N/A '" Date Removal Completed Telephone # t: City: State: N/A (N/ A :2 Wheat Rid e CO Type(s) of Asbestos-Containing Material Removed: ~ Contact's Name: Telephone # N/A An ela B e (303 422-1533 With my signature below, I certify that I possess current AHERA accreditation and state of Colorado certification as an Asbestos Building Inspector. I also certify that I have thoroughly inspected the facility to be demolished, as listed in the Demolition Site block above, sampled all suspect materials, had all samples analyzed for the presence of asbestos by a NVLAP-accredited laboratory, and have determined that no Regulated ACM exists anywhere in the facility" I also certify that I have informed the owner/operator of the facility or the demolition contractor that any asbestos-containing material allowed to stay in the facility must remain non-friable during demolition. Specify type(s) of ACM remaining, below: (check appropriate box(es)): General Abatement Contractor (GAC) N/A Sandelwood Manor CDPHE Asbestos Permit # N/A 3835 Harlan Street Zip Code: 80033 l8J Vinyl asbestos floor tile (VAT) l8J VAT mastic l8J Tar/asphalt impregnated roofing l8J Asphaltic pipe coatings l8J S ra -a lied tar coatin s l8J Caulkin l8J Glazin D Other, s eci : Signa" (In Blue Ink) Printed Name: [/ _ Chris Maron Date of Fina nsp Expiration Date Telephone # Cell Phone # 6/16/08 615 9/25/08 (303) 382-II75 (303) 817-8243 I verify that all refrigerants from air conditioning/refrigeration appliances have been properly recovered in accordance with AQCC Regulation No. 15 (for infonnation on CFC requirements call 692-3100). I further verify that all luminous exit signs (containing radioactive material) have been disposed of in accordance with 6 CCR 1007-1 subpart 3.6.4.3 (for information on iuminous exit sign requirements call 303-692-3320). CHECK THE APPROPRtA TE BOX: D Other Print Name: Date: 6/16/08 [gJ Contractor Chris Maron THIS Box tS FOR CDPHE USE ONLY: Approved By; D initial-310 D transfer-380 Date Issued: Postmark or Hand Delivery Date: , Form of Payment & #: Permit #: Record # * Regulated asbestos-containing materials means (a) friable asbestos-containina material, (b) Cateaorv I nonfriable ACM that has become fria~le,.(c) Cateaorv I nonfriable ACM that will be or has been subjected to sanding, arindina, cuttino, or abrading or (d) CateaolV II nonfriable ACM tha. t;has a h..!a~ rED probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the cour,.~Ctrl 'V demolition or renovation operations regUlated by this regulation. Note: Asbestos-contalning sheet vinyl and linoleum must be properly. "i .. c. 2'\\)~ abated/removed prior to demolition. ':\\)il ?." u." ., I\?C\) \" ~ionafj Fonn: DNA08 ~ ~ ....~ ~r- CITY OF WHEAT RIDGE ~.r~ Building IrispE!ction Division ]V' (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE InspE!ction TYPE!: Job AddrE!ss/PE!rmitNumbE!r: ,6A-~ /-""-'& n:-<;,~',dJ'. , J8~'5 JI.~/k'./>-' C>X>r.>€"'~? L/1f:u..; /k",C: .I _.J~ ;Ph7!YI A/$f'A:/ .AW~7F"" -Loc.?.A--'l/<;.....v 1.J.o AUcJ:F"'" A-77"J.ft...L P#~/f!P. . II'! ,.,_~ ('";/""':r~.J""", _ .!!1}~ J>Ap7>M ...vy>. ~~,LJ' o No one available for inspection: Time 1/.' &'D AM/PM Re-Inspection required: Yes No * When corrections have been made, call fOf fe-inspection at 303-234-5933 ..- Date: >?)..J...? Inspector: ~ a /' DO NOT REMOVE THIS NOTICE '~~K~,: " t Ridge t;;,~~,;,(,,:1' .})i; '.,',' ',' ,"', "', C~Mertia Mecha "",:-~';, '~, -'::>~.' ::::',: ':,: .ca PERMIT.. 08&85& '''-, , '" ':'..~IT NO: ;r ,I",,:,:':,:' --".": ~ ' -- " " " : :90El: ADDRESS: , ,~EStRIl?TION. """';''f'''<, 080856 , 3835 ~,' ST ,SoUer: ch;inge out and laundry roo ISSUED. EXPIRES: upg1;ade 07/30/2008 01/26/2009 i , " : **. ,CONTACTS . "* :;;wner 303/421-3600 <.;Ie " 303/329-8003 ':~~ub 303/628-7576 ,'i,*ub 303/711-2281 :::~Ub 303/29~-2999 :';:i:i>* 1;>ARCEL 'INFO ..' ',jJONl';; CODE. UA :-i;UIlDIVISION: UA .. Dick Whela Steve Diss 1 JohnA. Pi ucci George Hos tz Harold Rog 1;S 08-0173 02-2481 02-0522 01-9993 Spectrum Genera" Ccintractors picucei .ElA!lctriq, InC'." Plumbing by Geo:/i"ge " Rogers & Sons Ilic. USE: BLOCK/LOT# . UA 0/ '(, ',,* " FEE; 'suMMARy .. , ,I p~rini tFee ,::,plan ,R\Wiew Fee ::'"Tota'I ValUation i",Us~ Tax ::.. TOTAL ** ESTIMAT D PROJECT VALUATION; FES ~:~~~: ~7::~. 3,356. 6,532. 3 laEl,454.00 y:, ':', "Conditions. ,!S - App,roved as submitted. Subjec to field i spections. >':::' )(1:$1 't..:; '-,'] -- ::'i :111i, pe,rtn1t wait'lssued.1n;accqrdance w1tlh ,t provisions set forth in your application and ,is i!I~jec_t to,the la,1!Is:of th,e St~tft:l:of<'CQlo:;,a'!:lo,,-~p.~to the zoning :Regulat' ons and Building Codes of' wheat Ridge. Colorado o;r any 6therapplicah!e :Clrd~Elfes of~he,dti':< tni~pe~it'8Ml;1~1:r:~'Ub:aays,tx;om tbeOssue date. Reque ts for an extension must be received,pdot;'to eXpit,ation ,da~~-. i ,An,~~tet1S1();n'ma~'be9:~ntedat the'd scretion of the uilding-Of,ficialo rfthispermit::~1re$-'a::'neW'pe,rmitmaybe acquired for a f e of one~half the amount normallyrElqUi.red,;plOQyij:2ttd no ~:tlCU1geS:1laVe):)I~enor;wil~:'b~_~de intheQr'gina~p~an$ ana pecifications and any suspensio~ or aban90~t haanot !~~.~d!iil'dpne tHye"r..-. rf,'changes '~ye be or if'15uspensio or abandon-mentexcl!!edS one' (l) year, full'feee shall _~e.''pCl~d. for .a';new-PjJt1l)i:t... ':'. . ;'NO,~k of' any;~er:s:hal1.~'done tl.':~t~ 1 change the natral flow of water causing a drainage 'probl~;. ~orttt'actdr-sl'ia~:J;no,~~ftthe ~ilding Inspe or twenty-four (4) hour$- in- ad'Vancefor all inspectionsan4 ~U rece'i~e' fliti~ten""iWJiIr(:lV~1;,01?:',,~1'1spect,1er;t car(j~efo,re ,r(),Cli!Ied.ing wi tlls ccessi vephases of, yhe job. .' ..' Thets~a,nce pf,ape:rrni't,or,.the,_ approval of drawings and ape ificatiOns shall not. 'beconstru~.d to be ap'etmit f~r~'~r an. app~qval,of ;'any_~V1Ci.1~~o%t .f".tb.epr,ovi ions. of the build ng codes or any other ,o~iIlance,:' 'law, .rul~ .or . regulation. , Allplanreviewis~ 'ield'inspec 'one. date ~>: ;j, l, .:, .~'$,. '\", 'j;, .,:,:-:. , 'SignatutO of Cl>iot 'sui rig' t!iia1' ',,',': ", ',,,,,,,,' ',' "-"",,....- """"",' "::"';"': ,,::\,,', ""ie,, '"M',"" ''', "''''.-',':" "",",H:_''-'",:,'''''~_',,_':.'>'i:,, ':i!l:N8PBi,..:t~ 't','li_o.(a43~234 ,a 933 ' , il'EQUEST$WSTQ ,~ l&Y 3c1?M,A1f.{ USImi:SS .,",:', """',',,"" ,",':"""',",--' ",,''','''''')', ",,,,.-,,.-,,"', ", ,-- ElUI DAY ING OFFICE: (3Q3)235-28SS " OR INSPECTION THEFOt.LOWINq ElUSINEsS DAy: " City of Wheat Ridge BUildin~ Division 7500 W. 29th Ave., Wheat Ridi' e, CO 80033 Office: 303-235-2855 * Fax: 3 3-235-2857 Inspection Line: 303-234-593 i I Building p~rmit Application . Property Address '5g 3 5' ~a./~ ~ Property Owner (please print):,!), C ~ he t a. r\. Mailing Address: (if different than property addressj Address: II,;; 7 ~ s -I- / {.c; cJA< ,f ()f' City, State, Zip: e/u)~ Contractor: Date: 0 I :;Yl 'D'6 Plan #: 08- V;r7L} Permit #: OB' t$~ ~. ~ Phone 3/j3 -~2-I- :slaoo , .~ I \ G ~1'.~('o..P l\" s Contractor License #: Phone: Sub Contractors: Electrical City License #: 0 z-Z,\8 I Company: flew:< i I:'!..b<t. Exp, Date: 2~'If/O"t Approval: I i I Plumbing ~y Lil'ense #: 62..0$' Z:Z- Company ft;.J."1 I&t G4~ Exp, Date: ~/1' /Oq Approval: Mechanical City License #: 01- qqq?:> Company: RoVd'S -I- SOns o 1-0{'OQ Use of space (description): Description of work: DOl eV' Q,.. I a. u..JI'Y Nl D I1\. ,^p 1r;:;;).e. ::J Construct; (as calculate Sq, Ft./LFt added: (19C::7/ . '-/0 Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDIN AND AGREEMENT I hereby certify that the setback distances proposed by this ermit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenant , easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree t abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building ode (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: PRINT NAME: ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: fti?(f~ As. ~~ ~ ~ '"" OCCUPANCY).."'""- Reviewer 'SV~~tc .!{-t bl4J IN Jr t: '---If?'i7-J FIRE DEPARTMENT:: 0 approved wI comments 0 disappro1ed 0 no review required Bldg Valuation: $ * Sf- -tr ~ " ('> :;.::::::.f.':::D . ,. "\::, 2,: ~ <1 ~ tr"~ 'i' ("\ (" ~ ~tN ~ (l '-l--. 0 ~ '-~ ~ . ~ ~ ~ ~ ~ ~ ...:0';> ~'? <,c- Sb. " ~, t ""'-'\ ..- o -$:l- o <l> ~~e;-" ~ ~~ ~~ ~!ll arsi3 c"'~ =~~ n3::V'i =~--l I ~zz "" "" ~ ~ = '" ~~l:!~ 2~Pi;s ~5llE!i:;;: ~,..'" i!'5....=< o 'il!i!lgi3~ !ii!z!::!~F ars~~~...,. ~!i~i f!l !i c ~ ~ ~.tr~ 1 cr- ':j . :::::. f ':::b . "'I::, ~~ n ~ o-~ \> (\ (< ~ ~tN 1-.. o ~. ,-L i-- ; ~ ~J .~~ ~ <,t:. S6. <" -' i ""7' .- (\ ->l- g Cl> e-K ~ ~ ., ? '"" . 5L Co .., Vl CIJ ~ () )> )> a r 0 (J) - !;1 "I ,-,~ fTl ~~ &;Vi ...... ~=' s:: ~= .......... ~0 "'~ 00 fTl >> == . ~~ Z >>= II = -l ...... I \J 0 . >: z () Z-o ~s: ~z ~!;j c=~ ~i;!;j ~iij~a~ =~~ C);;::: v=; =>~ Z l!:!F ~~ ~zz ~ ;ll ii"~~"il"fTi o 0 ~I~:;;: ~!ll ~ cJ ~2~i 0 ar5S ii"....~ F!l l:i! <:> c ~ .!i:\ ~ ~ '" '" = ~ z ~ SIJ655 3Jl'Xl9'll SIJ655 O",!;? >>~ ~ =' == o ~ ,~ NEW 3~ 3'-1t all IIIMR JIIIIII54DX7!II Do!;? =~ ~=' = o IIIMR JIIIIII54DX7!II 'il!:l;jZ !i!",:;;i! z;: "'", !i! ~~ ~~~ ~s ~ ~ i a 01 ~ =", ~F:;::; =~ 0= '" = ~ ,- ,V " "" 'll':::: ,- O'-'~ ~2:S =~ -~ gz =0 c ~ =~ 8~ '" =' d~ ~Q "'~ >>~ -~ = ~~ ;z;~ 0 ~i ~ =~ ~~ ~~ == . 0 ~ ~ '" = >> o ~ ~ '" APPROVED Subject to Field Inspections Date: Signed: =~ ~~ "'Vi ""'" == , 0 ~ ~ >> '" cJ Plan checker itfff *" ~.tr~ " cr-:;.~c ~ . "~,2;~ (l ~ o-{\ ?(>(<~ ~tN ~ ~"l-.O~' " ~.; ~.;- ~, ~ ~ ,E. [:'f' 56 -=-;> ::-. t ('\ -?-- g lS"'" g r-I'b i;) ~ B ., [; ? 0 r-. = 5L ~ o ~ .., Ulm ~)> r ~(J) ......fTl ,~ ~fTl IIZ --l b a o ~ ~~ 5~ ~~ ~=' ~= ~GO o~ >- == ~- "'d s;:= ...... I" -0 ~s;: Z (j Z"'tJ ~> ~Z ~~ ==~ ~~~~ =~~ i!~a~ Q~U1 ~I ~zg GO GO IE ;S rlii!l!Iia ~ d ~i~~ = ~a i!Il....-< ~~-<I <:> = ~ !IJ8lIIj ~ !IJ8lIIj ~ ~ ,= ,- ,V " D8~ ="" =~ - =' ~~ NEW 3Q H' aR IIllIIl JIIIII5<<IX)lII D=2'S =~ -<=' Z'i IIllIIl JIIIII5<<IX)lII ~~~ I~ ~~~ ~ !S ~~ z !j! !i .!::l'" 51 a Di ~ :;g~ >-~ =~ =;e o "" "" '*--= ,= = ~ =~ o~ oUi '" =' ~= 0'" fgQ "'~ >-~ ~~ = D~ =~ ~~ ~~ == . '" ~ cJ = >- GO ~ d =~ ~~ ~~ == , GO ~ 'j;! '" d '2-orL{ THE McGLAMERY STRUCTURAL GROUP 3734 OSAGE STREET DENVER, COLORADO 80211 (303) 455.8988 Fax (303) 455.8446 JOB .(.6h'~L/4./H\") -"'" ,. I Sf1 OF / DATE 7/17 /0 P , I SHEET NO CALCULATED BY CHECKED BY DATE SCALE PROOlJC'l2Cl4-1 ISlIl'lIllShmsl2O!rl lP3dded) THE McGLAMERY STRUCTURAL GROUP 3734 OSAGE STREET DENVER, COLORADO 80211 (303) 455.8988 Fax (303) 455.8446 JOB SN-;l))L (../ 1 iJI"") I , 5/1 OF / OATE 7//7 /02 , I SHEET NO. CALCULATED BY CHECKED BY DATE SCALE PRODUCT204-1ISingIilShetl5)~111'idded1 , \ ,'~ "~'", --; - . ".) .4 .( JPr Remod I PERMIT - 080450 COlDlDerci PERMIT NO, JOB ADDRESS; DESCRIPTION: 080450 3835 HARLAN S'1' Health care kitchen. ISSUED, EXPIRES: 05/09/2008 n/05/2008 ... CONTACTS ... 303/257.1705 303/628-7576 303/461-0760 303/296-2999 I Mark Eledi~ger John A. PieuCCi Harold RO ers 02-2481 02-0522 01-9993 Sandalwood Manor LLC picucci Electric, Inc. Plumbing by Geol:ge Rogers & Sons Ine. owner sub sub sub .. PARCEL INFO .. ZONE CODE: UA SUBDIVISION, UA USE, BLOCK/LOTj!: UA 0/ Permit Fee Plan Review Fee Total valuation use Tax .. TOTAL .. PROJECT VALUATION; 48,000.00 .. FEE SUMMARY.. ~ I hereby certify that the setback distances p oposed by this pe it application are accurate, and do not v!olateapplicable ordinances, rules or regulations of the CitY~f Wheat Ridge or ovenants, easements or restrictions of record; that all measureme s shown, and allegations made ~re ccuratei that I h ve read and agree to abide by all conditio~s printed on this applicat' and that I as me full r naib! ityfor complianc with the Wheat Ridge BuildingOode (I.a.C) and all other appllc heat Ridge 'lances, work der this pe it lans subject to field inspection. I .~ IS" 1. This permit was issued in accordance with in your application and is subject to the lawS of the State of Colorado and to the zoning Regula of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the is~ue date. Requ ts for an extension must be received prior to expiration date. An extension may be granted at the iscretion of the uilding Official. 3. Ifth1S pe:nnitexpires, a n~ permit may b acquired for a e of one-half the amount normally required, provided no changes have been o~ will be made in the 0 iginal plans and pecifications and any suspension or abandonment has not exceeded one (l) year. If changes have be n or if suspensi or abandonment exceeds one (1) year, full fees shall be paid for a new-permit. 4. No work of any manner shall be done that w flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspe tor twenty-four (24}houra in advance for all inspections and shall receive written approval on inspection card before proceeding with ccessive phases of the job. 6. The issuance of a permit or the approval 0 drawings and ap cifications shall not be construed to be a permit for, nor an approval, ~f, any vi91ation of the provi~ions of the buil ing codes or any other ordinance, law, rule: or regulation. All plan revi i d4Ct to field inspec11ons. Signature of Chi dat INSPBCTION BQUBST LINBI(30~)234+5933 REQUESTS MUST ElE MADE BY 3PM ANY ,USINESS BU LDING OFFICE; (303)235-2855 DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. " \ i:) City of Wheat Ridge Building Division 7500 W 29th Ave" Wheat Ridgle, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Inspection Line 303-234-5933 Date: 1,:;3 l) g Plan #: 08-~';< Permit #: Property Address: Building Permit Application ?~?5 ~lAN 01 5A1vOAuvoCJO J1MOI2..... ~ Phone , p4#K.. 13tf.4:?t. C} M- 3C?3, d5":r'11-05 Property Owner (please print): Mailing Address: (if different than property address) Address: City, State, Zip: Contractor: .jpu-rru..vm 6. e, Phone: ~5' 72 '1- .roo 3 Contractor License #: Sub Contractors: Electrical City License #: Company: nCu.t!u' ~;f, Plumbing Cilb License #: Mechanical City License #:, c Company ('10<( ty GEc'vLJIt- Company i? oc; fi-/2S 'I -'OM ~, Date: Exp, Date: Approval: 1I/'1/~ Approval: ~/3DI6!. ~f-t.tA ~ Construction Value: $ 60'?J I<t ~R~: (as calculated per the Building V luation Data sheet) Plan Review (due at time of submittal): $ Exp, Date: Approval: ~'II'I5.. Use of space (description): Description of work: Sq. FULFI added: ;rJ If- Squares BTU's Gallons Amps ~,. i ~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this p~rmit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants.,easements or restrictions of record: that all measurements shown, and allegations made are accurate; that I have read and agree to :abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building qode (I.B.C) and all other applicable \fvtJeat Ridge Ordinances, for work under this permit. Plans subject to field Inspection. CIRLCE ONE:: (OWNER) c:&O!'IRACT~ or PRINT NAME: rtkJl11l(i CCc;.Gk SIGNATURE: Date: DEPARTMENT USE ONLY ZONING COMMENTS Zoning: Reviewer: PUBLIC WORKS COMMENTS Reviewer: . _ I "I . J#", . . irl BUILDING DEPARTMENT COMMENTS: .1)'l,,.../.-'!i? P- '.' .I'I~,--n' ~ I L ,...y (,. /o~~_i.J ,i;:"'{. /i~~_./"" .~CCUPANCY:_ . R17V~'e~: ,V//'L.-? -,oz, r(....'''',f...,.',r. .''l'.~~".~. .V~/'~. f . .y~ ,.,j - ___ '.r:..~. I~/)-i'......+-Il A':.}'fr"<-~~'!- '7 ~*V"..'J'~"'/' /r-'~"'- ./'~/' "'" . ~.., 7 , I' '"FIRE DEPARTMENT:: 0 approved wI comments D disapproved 0 no review required Bldg Valuation: $ iro~:~PECTRUM GENERAL CONTRACTORS 3033298032 04/04/2008 08:08 11785 P.002/002 RE: .. McGlamorv Structural Gro.!!jJ. Inc. :..!W CONSULTING STRUCTURAl EMlllEERS ~ co 0 LOR ~Q . Wheat Ridge Building Department ~ APproved. . ~ sA/uS' llUltDlNG OFFICIAL. DATE . Validity of permit: The issuance 01 a pennit or appfoval 01 plans, spedfications 111<1 computations shall not be a permit lor, or an approval 01, any violation to any of the provisions of the building, code Of of any City Ofdi~ances. Pelmlt$ presuming to give authority to violate or cancel the pIOYISIOOS oflhe Sandalwood Manor, New Kitohen E4!llIiIiI.. ~. Of other ordinances 01 the City shall not be valid. 3835 Harlan Street Wheet Ridge, CO April 04, 2008 City of Wheat Ridge Building Department 7500 West 29th Avenue Wheat Ridge, CO 80033 Dear BUilding Official, This is to confirm that our office will make site observations once demolition of the ceilings have proceeded to the pOint where the existing mof structure can be observed. At that time, we will determine if the new kitohen equipment, including en exhaust fan, hood, and make-up eir unit, can be safeh' supported from the existing structure or if reinforcement of the existing s'trucrture will be required. Please call with any questions. ..... ~, MIC Sincerely, The McGlamery Struoturel Group, InG. Sam McGlamery, P.E. Principal Integrated Development Consulting STM/smc Jeff Pelsley Jpeisley@mbcdenver.com 333 West Colfax Avenue #500 Denver, Colorado 80204 Office 303/825-7475 Fax 303/825-7341 Cell 303/5074105 3734 O.lg" Slrell . n.n.er. CD 80211 . Dh 303.455.8988 . 3!:)\ld 951'1 Ix 303.06.8448 . magim..tructuralgrDup.CDm 9ppSggPEQE 6E:EG 89QG/GQ/pQ GQ/GQ . .~ .......... 0:::: -'.... w~ ~<C <C> $)- 2~ 0::::-' ..0 <( ~, ~~ ~::.:-~. i . ..)\.\.. . (j) 0 ..c...........,... '\.",..J ................ ""7...\., ..;;;.....: f\.:..:..,:.:.... \.................. ~ ~ 1 · 'i.' U ....li ..... ..1' i..{{............... .... .... / .' ......... .' ... ...... - A ii' { /, ............ '" ...... / ;{; \:f ~ <0 i ~l);." ev." ~ ,'" .'. .........\,. / .i';' /' ~ · " ~ l .\ m ~~ / 0 /'/' ..~_____ ..........ii<ll::: ~ /') 0-"" ~ ~ ::> ......... ~"/' /' N-' · ...-:-' 0 /'/' ~IIV ~-' ~.rr / \ ~LL ~LL I /' /l..J.. ---------- ---- v ,12 ~. ~~ -q- I .....l< ~s> 0) ~ ~ 0..._,/ ~ ..-: -' N -' e" N '(f) l..L ~ LL L() I ~ <C I r-0 '" r-0 ~-'<.o 0) r-0 LL . p . ~ ~-' ~LL ;;..L. .'~ ..:' i~ 2~ I~ ~ ii) .s,! l~ J~ ~ ...~ ~2 !8 I~ \.7 w Z a: - :) ffi I- UJ U Z W - f- '-' - z :l: w U -I a: :; < o uJ . Q.. ..... < z u UJ II) :E 0 uJ Z '-' c( < ...J Z . < '-' :E z ..... - trl Z z a < 0:: ...J 0.. a.. ~~ ----. ...... .......... .. <.: 10 0 ..) 5 10" ~ ~ I ORIGINAL SCALE: ..... 1 If == 1 o' 20 I > .' '. ..... /' . ~ <::> "-:--1 [. ..... ;.. ..... ". .' \ \ \ it ~ " ":: " i . .' ...... . :'. :...:.. " . . :'c- ~. /.*. i te. l.' "'- I.. r '~.. ~.~ -r- L.t..- .... . ;',.. '. . ". .:.' ..... ..;.............. .................. .......... ... ..,..... ..c .. .......... ,....... .' '{:.\ ";, ..... ............./' ."...:./"'::.:..."" A..' ..:.... v) ... ~. ,,/ " . . . ..... ......:. ..CO'.........\'. ...... ........... ..".... ...... ~. ..:.........:t.:.......'. \......: .... . :/.:..... . .' .; >..~~'i ..' ..... .:'" / \ . .. /' J / . bc~ /" .~ ......~ ~< .~ '1.~..... ~ i.. '.' ;"i't;" I ~ 'r "'f - _;;<::- k/' 'i\ i~, I' \ / \ \ -. tP MID. 0" r-0 tJ' I o ~ 0,," .":. ;:'''\ ~ .........;.; ~ "x . ... ..... '\~ I"'T'\ '\.... ' ..... .... ...;. ..' ~o v~ ~ ~\" N -' '<\0 ~^ ~ LL a ~\ ~ 0 0 at>< r-r)J" ~LL '\ ,:}..:ir", !:.:..........:. . . '\. :..:.....:.......:::".. ..... / "'" . --- ~.u ..,. .. t~ we <0 ^)- /' ;':'.. . 4" " ~............... ,,~ a -q- . N..-J ~W -~------ . ....... __I' .................f 'r''';'';.:.' :~'/t'-~-.LI:-::::~12. L - . /~ ~.",~o --~,,~.. '" .'. . ' ~V ---- 0' N' "---,..... <.~ ! . " m ~ ~ ~ -' ~~. . ~ "7 3. r: · - -: ~ -' N........ ~ ~:\l'i;/ ~..., ~ ~ ~ , r-0 ~.~~.. . ~ ci --J f7"" ~<;~ 12~ ill /~ii> ~ o (j) ...~/./ I 0... r-0 ~ l'I';t;\ e >- ..J-- .1. ;]J I- 11:1 0:::: n ~-' I- .. '" ZLL "'N L() - - l' V r CD 0::: ...... ::) :; o '. m 0::: ::) o ~ , ~ " ~~ ~~ ~~ ~ ~h a"'""'-t aV) ~~ ~~ ~V) ~t: ~~ V)~ . :. ': . ; . . - 0) v .....7 '. .................... Ii ., ~ ......... ~, ...... ~ ~ :o~~ ','.' ..... ~u ...,. .........N "'''''''S~ ~N N NO) ) ~ ~r- N N -' ... .../ '" ~LL % 66' . N .... N N N ~~ ". N..-: i~ ij I~ , " '" ~ / .... ;/ ..' tZ cr:v .. VJ ~:':'! ",. /. '" / / ~7:N:' o / ~ ~K / . / ~ a ~~ ,'\- 0) ~ yL LL · ,. -' b/ N .... ~~~'V'K~X~S"~ ..tc/.'. , "1~~~~ .."- .~. " " -' : ~jl ~-' ~7~Q to b ~ LL ~KJ ' ~ D 'j % M. t ........' ~ ~.....: u 'l~~ ..". 7'" /i\ //.._' ~_ I I'U~'. ,C;:' ) ~ . <-? I , .... 41' to :7 ~ """it) "0 ~ "" "~ ~,' .... ~ -' "~'tlfiis:,{; ~ V ~ lJ::::: . ...... -q-I ~ 0... 2 .(j) ~ <( 3: L.() ~ OL() 0::: · i 0 <C X : '" t-(\I Wo ~ WN P f!o .... (/)co O<wO ~~~o <( ...::; ~ .. a... ~cr: ~ N~ a.. ",z "w .-0 ~ 41' N " .- ~.~ r-01 ~u\ ~ I. '-/ ~ ~ ~ <'v .t; _..~ ~~ ......~. ". r-0 o o ~ ! ~~ - r __~o II' ~11.5- L.() ..... -, ~. 0) 0 < ",. ~z . a N mO · .'. ',. () ~.~ O)Z ~ N , ~ Lc... ..-: 0 ..... 0.55 % U >;{~ r'.\~ / ~~ .X il" ~ '!. I ............. ~ N ~u ~U "J -' 1}' O)oz O)z.<J, . ~ Hj,,-. · 0 . .~ I ~~ ~u ~o N '. .~. 'i::;;;.it,; ; .."~<,.:"'":~.,.. r ~ f .N ,T . INN .~ d"<"':;'}' N ...... ;' ~ ('(. . . t~I, .;;;N;' "," ..1 r; . !;o/l~N . 1 '\' ~ .' ;..l!;G.\. 'j . rr ..... . . !)l H" ,.~,. ...." .... ""'L.f,.i . Xl .'iU ~ NJ ~ 'ji:.l\/",_, . ~ ""1 fJi FF~ f!r]~ "'/"'f . ... "iJ I'iJ l'iJ ~ '['\J NiJ l'iJ '1l . ~ --.J y--I. 6\0 <0 0> A' /' / -~ ~ .0' C O~" ~-' o ~ l..L '-/ ~t ~ .s 6\0 , ~ <0' tk" [ _ ':7"'1 .. ( ~~' ~ ~~\ ~\\\ ) /j~:( I J ::> ~ - , ! ~ '., a 0) . N-' ~LL ~ f 0) ,0) . I. . ~... ;.. '" '. ,,:.;:,~~ .... . \ ~ .tOU '. '.. ........ .' .,~ ~it; N~ ". /:;.......i.....~ C,) l.} ""e'" . ~, . 0( .)( <..0 O. ". NZ' ~8X i~U 'O)Zi .0 ~ ~O ,'. . . c..o a . .. .... ": ....;..:..,.. . ............ ............. % ~ .() Pd\o. /b () ~/ ~'.<~ V 11I"./.:.. ~>..." j%' ; "':':S':.i.'.t~~ ()I ) · ~~ /.., ~, · .~o ~\L'.. 0) Z x:0\ " · CD .,;~;;~ . ~ ~ x:~~ U~~;:. -q- ~ ~u ~',P ~-' ~ - .:. ~.II'""", ....~ '-~ ..... I ............... :. . , ':.. . .. ' . '. * r-0 i ',::;..... <../ c' :. .' ': .:: -q- U · ~z , .Q:' .~ .... '; ~U .f . Lf) o . 1'0-' -r- LL ....... ....... .. < rY~ ~~7 ~ ~K'" '. - 7 rZ.33 % 0) N ~-' ....... ~0<LL .: i ~-' ~LL o ~ /0- e : :\:.: ",? ':' ocr .:~~~ '. m .; ; .: 1. ~ ..... .... .., : ~ I o . to o . . . : ....... . )0- m . ~-' ~LL ~ ....,'....... : 0:::00 I- WW 0...---1 >-2 1-- ~ I ~ m o ~ ~/. <' .~:.;; . L. . \:~;.i:~ 0) N Q) a ~ .' l' ........, "-:LL -r-LL~ 0) ~LL ~LL ~i~ ,........ ....... t. : .~~... ':~c<, . :;. . ..' .., .. f ; i~ ..' . ~-' ~LL ~ -' ~o ~LL 0) ~ ~ O. ~-' ~LL ...> 0:) 2' ~..::<>...' .:........... .0 0 I L() l[) ........ ~ ......... a........ ~~ 8 % ~ ~o O)Z .0 ~ ~O .l ll) I~ N ~. .. ". . ...:...... . ;:.. ". ..' . "..... .. 0) r-0 a ~ . N-' ~.lL ~.. . ..... . ...'..:............ . ...(. ..'" '>.. . '. ",. '.: Z cno ZF Qa. (1)- 53 wen ~LIJ o .... .. ..., . ..-:-' ~LL ". f, .;lr::~;~.i~::~~::~."c.~:::: ~~;}:. /!/;lfi. t".... ) ..' ,/' . L:,~~,~.?\ ...\t ........ .. ................' . . . -q- ~ . r-0 .. :......: ': .......:. ;.~..,....,......."...";,~i ~ .......... ............ ~ .. .. .,:::~::( ...~:> ...~f .......... . ". .:: : ..'{!..;'.~:...:I~" ........'.. 1 .......... '.. ....: ' ';.\ '.' ;~...::~:..{.. C:". [f~:~JJ . .. '....., t:..:,)1r,.~..t'yr; .. ....... \.....,;y: tC':~:,Jl ' " '.' .. ~tN .~ .~ //1 ~. . l![~:;ml' {':if;, ~ Fl:~ I:, ~ 0) .~ ~~ .~.......~ .~(./ ; ~~l;~( . rNi1.. .~ ;..."./.3 '~.{M""" N\J .hN ITN UN ~ ~ :.::.,::..,; :. ^':.~,.....;.,~.;,.. : ; . . r . :............. ...., i'''.l ....~....; icL, .;j . . i' . "ce.: .. N~'/ s::: ...)',.1 .."- "-~, "- N . . ~ .ce. i i" <;{ ..,....,/ ". ~ NT fr..;';t'" . N " . ;' i',{ r~:~: !~i~~ N ' n,) ::11' r re.}'; . .... ft::l w\J N ;:;,' ~::i "\ . ~ o . ..... .......;0... ..... .. '\.. ..f: N .Ii},' f"'; , ~"f'b ~ , Ii . .... T';' ....."".....,' ...... : : i/. '/.j.. \ ......... '..' @ .. ~ <( o \ i I I ...... ...... ~ H- 0.: J: ~ ~ ...... ~ f 0.. J: ~ '" t;! ...... N Q; I j::- ...... ~ .,..,..../.. ''';;,':.l>);';. col o I o ..- I t") o . -q--' ~ ~ I ",0 O)Z .0 -r- ~O f <J . ~ /~y ..... ..... '.. . I .... ~J/ "'-. /, ~ ~ ,,"' . ,,~ "~ ~..... ~;::~ ..~ ... " t-. ,. :.:....: ~ <( o i/...;"...".....~ "5:, ...i...::....;:',,, rt '.. ;~: ~':J' .. ..........,....,. ........... ..... ". ii. .'. . , :. ~ '. . (\:::::. 1 ~""'''''''''''''''\. y,...................,......... ! !~.f \J E:E:' , f..::i:~".'$....."') ~.; f . ....f..l ,.....'..~>.."l..=.~~.. :; ..:..,.. ............. .... trti.. n;.;..:/iliP':"\b ..~ ~'I'/ ,rtL~~f~ ' .:; ..; r~:::~ i.... '. 1~f.(' ,,~~N~~~~JC~~ ,h~J!,~"'~~~~' ~w "~i.~~'~ '" i . " cr...... iiI:J; , : ;'JL/ I~ ~utICIJOl.De"dr*ent N :1.,/ .~:~ tIll': "..' "'i,~....,,,L .' 2. '/ LJ ~PP'ovecf ii!." "J"~'(J CD Ie] rC)...Tetr :..J'!, BUKDINQEJFJ:femJ:' . -.- ~c~9/ri ';[''01./. 1../ . . val' ,ii '. '. .:'j,,i .. . · OAt'! f : ...-,.. , . .. ..1..5 II:] ..:, " idly of ~ "'he Issuance of a I ermit . . . ,.;-' .......... "'/'1 : r\,.\"...~ ii' ~.~~i!~~~ not.. a_ rOf;~ r:::', ~ ,/1 LJ \\ // '. t..,mw. ~,tI~~:O!:fbe~,aw_i"....an'vtelatlOnlo " r', L.. .t :;..11.. .~ng 10 9!ve autho~jty 0 vioI~'~.Qt.~=r~... 9 ~ or bttter ordm? lI"O<<! of the ~:t" Mal ,~s of tfte, .. ~D .w.V.. lnot,_vald. ~ .... o I N '" o I 00 o . :~"":"""'.;;"7'.'~ '. ...:~...,"'<..;.;f~;~;f;; . ~ ~ ~ ):. ~ ):. OJ ).:. m f3 OJ 0 ~ i ~ in <( (.) W ~ W o 0 0 , ~~Q ..' . ..' C":ln;"'f, I ':;C' ;: ""(.,'" "lc."." ,dY':"; , ~ ;,"'; ; ...' ;.......... .................... ..... ; . ,; ..... :;:'; . t *C r:: to Ci B J4 .11 15 1: J Q ! 9 ~ i oe- i ~ w .,.. .......... ~.......". ......".. ,.......,... .......,.... ........... ..,.....................,.. ...' ,.... ..,...... .....". , ,........... , .......,.......,...... " ,...., ........,. l;J ru; ~(,3,..., dN ....~F.;;.'~;i"~~. .' .'. NN " I o z m o ...., ; ;~~~;,~ > <...............;... :.i1r;~:' :.J. .......... .;;, t... if:;.};; n .......lijj,;~; . ....... M. \<q, ,\iI '\' " '- 'ji\t;o;'/ '\..~ "..... ..' )i............ ,.td~ t:s .' () .. : .. \..(,...,..:.:,,'.......,....'O:"~ . ! ~;~:~~l r'" .. t_",l t:;Jj>,;,~~'~~:J ../.i;..;;.;;';;;~::zc;;t;. ...... ....:;;... ; ....:..' ;,:...,~. ...,;;t. ;:":":f:,.. fi....) .. .................. ........ . ..... ......,.' ..... . .. K... ~ ~~I ,M~ '~~ I ; .;;:....{~;t....,... .. "": , 'l''i!'=~~ ...r"\.. T 1/1. .. ! .... ....:... ; .. : . . .: ...'.... ..... , , 1..,~ ; (;,::..,:':~...:..;.".;;~.r\ , :)'; ~ =.;,K~';~::3~ ... ......5 '. ....... . SHEET NUMBER ... tr . i ~ ~Tlr ~ r l f .~ .~t { .. ) T"~ '.. ~. .. /;...... J U \~"..;;1.' .......,..; r-0 a . lO-' ..-- I I 1 OF 1 ; ... rr''':''..",.".....,.'''.p.,............ i : .,.e''';, ..~ ; FOUND PIt ~ CAP BUROIaC - P.LS. 8010 ).y YDT OF PROf'ER1Y CORNER ... ....... ....... ~ rt) ....... ! (:) ...... 8 N ;r ....... ;:;; ~ "0 c: to 15. 0\ c: =0 e 0. a.n o ,.,.,. c: m ti: B in ""'" ~ :9- ........ o I N ~ o I to 9- .~ e Q. ~ en o~ ~o.. w:C 3= I co.- ~~{CIlu tb~w~o"> r(\l 0...... o z FOUND PIt II CAP IJURDIQ( - P.L.S. 8010 us- NOR1H AND 0.1" EAST aF PARCEL CORNER 10.87 Fl f- W W 0::: f- (f) z <( -..J 0::: <( I 78.60' S89-53'59.W PROPERTY LINE 50.00' 5.4. 589-53' 40.W 20 0 10 20 40 ~ 'I I ORIGINAL SCAlE: 1-=20' 38TH AVENUE Wheat Ridge Bui,lding Department , ~- /' ~pro~ed - ~ >/s#~ fJUlLOING OFFICIAL .' DATE ~ 'alidity of permit: The issuance of a permit or approval of plans. specifICations · nd computations shall not be a permit for, or an approval oft any violation to any of the provisions of the building code or ~ any City ordinances. r=>ermits presuming to give authority to violate or cancel the provisions of the building codes or other ordinances of the City shall not be valid. MH MARK HOSKIN ARCHITECTS 1732 WAZEE STREET SUITE 201 DENVER, COLORADO 80202 TEL: 303.298.0755 FAX: 303.298.0934 c::: 0 Z <( ::?E 0 1--0 W~ 0 Wo O::...J 0 1-0 CJ)u Z 0 <( ~ ...JW o::(!) ~ <(Q ::r:o:: 101- ..J ('1)<( CX)W <( ('I)::r: 3: 0 Z <( en JOB: DRAWN: CHECKED: DATE: 629 PAZ JMA,MEH REVISIONS: SCHE TIC DESIGN DESIGN REVIEW DESIGN REVIEW PRELIMINARY PRICING CDS 06/27107 08103/07 08/16/07 09107/07 03/31/07 H ....~ ~ r CITY OF WHEAT RIDGE ~'r~ Building Inspection Division ~ (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE ~-'" ..-::>~-:) . .,:::::}.,-- \ Inspection Type: fJl:;,,~ - .rfj/{,tYdir. ~) Job Address/Permit Number: . +bt1!tlIJ l) ~ - / ~ j ....,. ~ ~ CITY OF WHEAT RIDGE r'Fy;;j Building Inspection Division ~ (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE ffi () ~ Inspection Type: - - / U (~/ 1'l1i0 Job Address/Permit Number: !;;; ~:.,J 1~fw :;;;1) o ( IJ No one available for insRection: Time Re-Inspecllon reQUired;@ No * When corrections have been made, call r"\-inspe.ction at 303-234-5933 ~/.J!t r! . /\-,,/ Date: ~ 00 Inspector: ,~J DO NOT REMOVE W",/~M -- ,-,-,-, ';PO--" u .....~ ",,- CITY OF WHEAT RIDGE :r"rJltl":;, Building Inspection Division ~ (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: ~ -- ,Ml;/;"M-Nf~ r;;.1c Job Address/Permit Number: ,~Lh-l'l/Ar.) ,;; -'I~ o /? \ <- , - -0 i) J!-r:<: .' N ;r-AJ o No one available for inspection: Time Re-Inspection reQUire@ No * When corrections have be;;-made. call f~t;.J, -inspectio Date: (r?!:bAd' Inspector: l/ / I / DO NOT REMOVE 7', ~~M / / / i l_____________ ~-'--~~------ ~~~.( , .... r CITY OF WHEAT RIDGE ~'r~ Building Inspection Division !V" (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE . ----- . =:~ f-. ..~ Inspection Type: ~~-~ I~;: - (l\-Of U Job Address/Permit Number: -> - s <;. ;'}1 <LLt"./ S. .. -- J-/1---1-'1 ,0 L<:]?Z./.' ,1-L I -' -r----- ~7--/ ~~ij / ' / // / L1 ,--- I - VC/:/,L-- '~~ [J No one available foriR,~ion: Time Re-Inspection required:l vei No ! . j / 'w"," ":717"-'~" W,~j_'O "'-- Date: r' -, ." Inspector: ,4.#(/ o NOT REMOVE tHIS NOTICE AM/PM u .....'" 4 or- CITY OF WHEAT RIDGE :r;r~ Building InspElction Division IV (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE InspElction TYPEl: .!;.iWE over hlf Job AddrElss/PElrmit NumbElr: :JS'l>;/ ,h)j"t>,< .r t?-.Lh' 0;;,::>1"5"0 PVt!f~/ J- w? ...-1' #z??'t? - .:>tf &/(, /1#" 7:"'(;( - .1/ ""t' /"" "IV'EtP ,t&;;I)," ",-,,-hI - cr! #-1/1 /H"':;'} , - ~.vnb?Jo u-~j.J ;/'7". /It) - 4?i! o No one available for inspection: Time ft": yo AM/PM Re-Inspection required: Yes No * When corrections have been made, call for re-inspection at 303-234-5933 Date: f/;77"~9 Inspector: ;r;:; C / DO NOT REMOVE THIS NOTICE .--~----- .--------- ~'.4 .- ... .. ~rU: )P'" , City of Whe t Ridge 1 .. PE&MIT NO; JOB ADDRES$; , DES,CRIPTION: , I ";,d'JQ~el'eialll~lumb. g PERMtl'.,; ~9 I I , I I 080529 3%35 ~LAN ST Instali pax-trial new s'wer line6 Ii ISSUED, EXPIRES, install manhole OS/27/2008 11/23/2008 inptop' U' CONTACTS U. owner: 303/215-1348 ~,,; ge Brian wHk' e sandalwood M~:t: 06-0162 Apex Pll.\mI:liI)gI*" **t>ARCEt INFO .. zONl;; CODE: UA SUBDIVISION: UA USE; ElLOCK/LOT#: UA 0/ Permit Fee Total Valuation Use Tax **TOTAL ** ESTIMAT D PES 217. 0 o 153. 0 370. 0 PROJECT VALUATION, 8,500.00 UFIlE, SUMMARy U I&ff;1l '("~'. ' 'c." Comments, Conditions, Subj~ct to field i I ~r~Qy:certify thatthese~~CkdiStancee jposed by this pe it application areaecurate, anddonotv!olatec~l1Cable ordinan,ces, rules or;r;;egJJlationsof the ,City f Wheat Ridge or ovenants, 'easements or restrictionsof_recOX"d,; 'ttul;t:,'1l~l' melleu~ent8shoWIl, arid ,allegations, made are curate; that I h ve read and agree to abide by all COhd:ttio~p:r"inttr~.op this "'".~,,~ _ ....,',,_,., _""..,,~ _".., .. - _, __,,,,,,,, n',e - .","': '.. appl' eatRidge.' anqes, for work ... erthis permit. lans 8uQject to field inspection. . . ! 08 inspec;:tion Tl'iis permit was iss-ued in accordance wi,th' Sta,teOf COlorado..andt:o the Zoning RegQla ions and Buildin ordinances of the City. 2. .Thia,permit s~ll ,flPtp~re18,\) 'days from th,~ lissue date. Reql! date. Ju1 extension tnalY be~anted at the 4iscretion"_ o~ the If' this _permite)(:ptres; anElw permit maY~b . ~~$~~'rii: ch~e8, have been Or .will. be made ...in the. .""nal plans"~ exeeededone (l}YEie.r. If changes have:,!,' n or if suspenai E,,::;t~!':::~~:;~~~; ::1~~i.t~:~~;~r C~~:~~y:~u~ ~~ti::u:~~:C:~l.O;.~i.6~1~~eC:~ )~z=~r~lp~:i~:9a:;t: an ,approval-of ;ny _ latiofl oft; provi.ions of the buH ~1 plan re ject to fiel in8pections. fortl1 in your-' a:ppl~catio1'l: and is subj~bt tt> the lawr. of the Codes of Wheat Ridge. Colorado b~ any othe~ .ppiic~le 1. 6, ts for an extension must be received prior; to expiration uilding official. e of one-half ,the amOunt normally:t1:qui~e<:l~; provitJed:i1O peqiflcations and any ~uBpensio~ orabandohme~t has not or abandonment exceeds one' (l) year, fUll,feesShall ura~~\fl<nll of water causing a dtdria:ge prbbl$'it. 24) hours in advance for all inspec~ions and shall receive uccessive phases of the job. cifications shall not'be eonstrued to be ~ permit for, nor ing c~s or any other ordinance. law. rulebr regulatirm. 3. 4, 5, ;-', <lat Signature o~: .' .', ,'.. _' ~:> I INS~B.ct'ION UQIm$TLII:IB. I (3(13) 23"t5933 REQUIlSTSMUS'l"BE '.Ml!ll'lE' .5:'::, 3PM,AN'{ rUSINl;;SS I . I I Bu WING OFFICE, (303)235"28/i5 DAY FOR INSPECTION THE FOLLOWING Elll'SINESS DAr. City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 . Fax: 303-235-2857 Inspection Line: 303-234-5933 Date: 5--),,7-08 Plan#: Permit #: Property Address: Building Permit Application 3V5 HArt"", Property Owner (please print): :SAVldA!""" c) Y"1A",<<,,- Mailing Address: (if different than property address) Phone: Address: City, State, Zip: Contractor: ADI!'Y ? i"'.... b:;y ! Contractor License #: Phone: 30)-,)./'5- t3 '-/8 Sub Contractors: Electrical City License #: Company: Plumbing City License #: Company Mechanical City License #: Company: Exp. Date: Approval: Exp, Date: Approval: Exp, Date: Approval: Construction Value: $ ~'5W - (as calculated (Jer the Buildinfl Valuation Data sheet) Plan Review (due at time of submittal): $ Use of space (description): Description of work: L J _ ., _ ~ I,,,, e- . ." ~"\'1 ..L..-.) 1-", If 'j>."....frA Iti!.<</ ~e""'~ r"~",,i' W/~..ll.ole ih fr-c>";-~7 Sq. FULFt added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) PRINT NAME: SIGNATURE: Date: DEPARTMENT USE ONLY ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: BUilDING DEPARTMENT COMMENTS: Reviewer: FIRE DEPARTMENT:: 0 approved wI comments 0 disapproved 0 no review required I Bldg Valuation: $ OCCUPANCY " , \ . " \ / ~ ~ ~~ ~ ~, CITY OF WIiEAT RIDGE ?"~ Building Inspection Division !V (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 6 ~S~C:ft/.-~ ~/rJ 0'0 Job Address/Permit Number: "}',f".>.'i {17M"/ AIJ ;:>T /} kQI )&)/ (=;;lE2-77Z/L /4-, k' ITC.~10V kr0V'7<) o No one available for inSpe?' 7 Time Re-Inspection required: Yes ro Date: ~7 ~;/ Inspector: I . I DO NOT REMOVE TH/~ NOTICE AM/PM . -, ~u.( .~ City of Wh~at Ridg v ~; ~ ~ CofillnercialPlumbig PERMIT -080505 . i PERMIT NO; JOB ADDRESS, DESCRIPTION, 080505 3835 HARLAN ST Install partial new i ~ewer ISSUED, EXPIRES; OS/21/2008 ll./17/2008 Un . .. - CONTACTS -... owner gc 303/423-9204 Seott Pek<!-s Sandalwood Manor 07-0200 Piccolo Excavating .- PARCEL INFO _. ZON!';; CODE: UA SUBDIVISION: UA USE, BLOCK/LOT#; UA 0/ Permit Fee Total Valuation Use Tax ** TOTAL ** ESTIMA FE 108. c\p2-'f{ -. FEE SUMMARY -. PROJECT VALUATION; 2,800.00 50. 158. Conditions; Subject to field inspection. rhereby certify that the setback distances p~oposed by this p ordinances, rules or regul,ations of the City cjf Wheat Ridge or measurements shown, and allegations made are accurate; that I application a that I assume,full responsibi~ity for complianc applicabl eat R' Ordinances, for work udder this permit. it application are accurate, and do not v.iola~e applicable ovenants, easements or restrictions of record; that all ve read and agree to abide by all conditions printed on this with the Wheat Ridge Building Code (I.B.C) and all other lane subject to field inspection. 1. This permit was issued in accordance with ~he provisions se forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulaeions and Buildin Codes of Wheat Ridge, Colorado or any other applicable ordinances of the. Ci ty. ' 2. This permit shall expire 180 days from theiissue date. Requ ts for an extension must be received prior to expiration date. An extension may be granted at the 4iscretion of the uilding Official. 3. ~fthis permit expires$ a new ~ermit may b~ acquired for a e of one-half the amount normally required~ provided no changes have been or will ,be made in the original plans and specifications and any suspension or abandonment has riot exceeded one (1) year. If changes have bean or if suspensi or abandonment exceeds one (l) year, full fees shall be paid for a_new permit. 4. No work of any manner shall be done that will change the na ral flow of water causing a drainage problem. 5. Contractor shall notify the Building lnspedtor twenty-four (24) hours in advance for all inspections and shall receive written ' approval on inspection card beforejproceeding with ccessive phases of the job. 6. The issuance of a pe it or the approval at drawings and sp cifications shall not be construed to be a permit for, nor an approval of; y ation of the prdvi~ions of the buil ing codes or any other ordinance, law, rule or regulation. All plan rev ject to field inspec~ions. dat INSPECTION RBQUEST LINK. REQUESTS MUST ElEMADE BY (303)234~5933 3PM ANY .USINESS BUILDING OFFICE, (303)235-2855 DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 - Fax: 303-235-2857 Inspection Line: 303-234-5933 Date: Plan#: Permit #: Building Permit Application Property Address: ';? !,'-y,5 .tMl2bhJ .5-r Property Owner (please print): \ ~hd/v.I.Mu' I'1't, /1.,./ Mailing Address: (if different than property address) Phone: Address: City, State, Zip: Contractor: H'vv,t>h C'Ict:<vt> );"~f Contractor License #: 6, 020D Phone: :,t} '3 " 'Ii?-1 "-" 1/1/6'? Sub Contractors: Electrical City License #: Company: Plumbing City License #: Company Mechanical City License #: Company: Use of space (description): Description of work: Exp, Date: Approval: 7~~'lIl1l "'ll!,.... 5".",,<.-- t ,1I\t- t'ttr ~\"'4.\ . Exp, Date: Approval: Construction Value: $ ZBOD ~ (as calculated per the Building Valuation Data sheet) Plan Review (due at time of submittal): $ Exp. Date: Approval: Sq. FULFt added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenant$, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: jWNEf3l> (CONTRACTOR) or PRINT NAME: t h-rT 'f'f lCA. :<i (CONTRATOR) SIGNATURE: Date: ,-z/-pg DEPARTMENT USE ONLY ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS' Reviewer: FIRE DEPARTMENT:: 0 approved wI comments 0 disapproved 0 no review required I Bldg Valuation: $ OCCUPANCY: q"'~l'I!I!MI,ql~~ ~\.4.( ~! City ofWbeat Ridg CowmercialPlmnbi g PERMIT - 080465 PERMIT NO: JOB ADDRESS, DESCRIPTION, 080465 3835 HARt.l\l'LST K}&.. InstIl new 10~gal. grease ISSUED, 05/13/2008 EXPIRES: & sewer line in BID tr --- CONTACTS -_. owner gc 303/717-2281 Sandlewood Manor George Hoffsetz 02"0522 Plumbing by George *. PARCEL INFO _. ZONE CODE: UA SUBDIVISION: UA USE; BLOCK/LOT#, UA 0/ Permit Fee Plan Review Fee Total Valuation Use Tax ** TOTAL ** ESTIMA ED F ES 435.90 283.34 .00 378.00 1,097.24 PROJECTVALUAT!ON: 21,000.00 .. FEE S1:JMlIIARY .. Ir~]) Conditions, JS, Approved pe~ plans & engineer letter. 5 8/08 I hereby certify that the setback distances proposed by this p rmit ~pplication are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I ave read and agree to abide by all cOnditions printed on, this application and t m. tu onsibility for complian e with the Wheat Ridge Building Code (I.B.C) and all other applicable Wh Ridge r work under this permit. Plans subject to field inspection. ~. dat 1. This permit was lssued,lnaccordance with the provislons8e forth in your application and is sUbject to the laws of the State of Colorado andtQ the Zoning Regulations and Bul1dln Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City~ 2. This permit shall exPire 180 days from the issue date~ Requ sts for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a ee of one-half the amount normally required, provided~no changeahave been or will be ,made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspensi n or abandonment exceeds one (1) year~ full fees shall be paid for anewperm;t. 4. No work of anym.nner shall be done that will change the-na ural flow of water causing a drainage problem. 5. Contractor shall riotifytheBui1ding Inspector twenty-four 24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with uccessive phases of the job. 6. The issuance of a permIt or the approval of drawings and sp cifications shall not be construed to be a permit for, nor an approval of, 'any violation of the provisions of the buil ing codes or any other ordinance, law, rule or regulation. All plan review is . t to field inspections. Signature of Chie ciat INSPECT!ON REQUESTSMU ST LID; (303) 234-5'33 BU WING OFFICE, (303) 235-2855 BE MADEl ElY 3PM AN'{ BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge. CO 80033 Office: 303-235-2855 . Fax: 303-235-2857 Inspection Line: 303-234-5933 Date: r/ It-I u i Plan #: Of- QIJJ Permit #: fJ () C Building Permit Application Property Address: "?'?~5 ;...fl/-r / ""-- $;: Property Owner (please print): ~<'} / I? "->~~ ,r7 rl-n ""' c- Mailing Address: (if different than property address) Phone: Address: City, State, Zip: Contractor: Pi<,~;: ,'~ 'r '7 h <","...., "~ P Phone: Contractor License #: Sub Contractors: Electrical City License #: Company: Plumbing City License # Company Mechanical City License #: Company: ~~Al ;,l-o ~/;) Exp, Date: Approva I: Construction Value: $ .;< ( ~ (as calculated per the Building Valuation Data sheet) Plan Review (due at time of submittal): $ Exp. Date: Approval: Exp, Date: Approval: Use of space (description): Descriptiqn of work: 1:"..,~(\ IU~ G,.-.......SOe t('AP 1\-0d' $~ 4'~~ A-..d 10""-,, ,>"""e,.,- k S .fv.",.ert Sq. FULFt added: Gallons /~ Amps l~~):/~ Squares BTU's OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (l.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: PRINT NAME: (OWNER) ~NTRAC~ PERSONAL REPRESENT~WNE~NTRATOR) c,"""~3 ~Q SIGNATURE~/0 DateS.t.'<:j'{'""" DEPARTMENT USE ONLY ZONING COMMENTS, Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: BUILDING DEPARTMENT,9~MENT~' /1812i'//.': ,J PI;.1 //f-f,/5 ,~' /~v,/ / T;<~ . Reviewer/~ //:.-~'-'_.,,- 5/5~":) FIRE DEPARTMENT:: 0 approved wI comments 0 disapproved 0 no review required r Bldg Valuation: $ OCCUPANCY ,!1r""'1lij!!<*\'~.",'.r,"~:~~~~!\~",!'\"~I.Ill~.",~II.~F'~'W^._'''''''''''''''~~,""",~.J,. ..~..( ~r# ~.. , City of Wheat Ridge I Commercial RemodJl PERMIT - 080450 't' I $1ElU4IT NO, JOB ADDRESS, OESCl<IPTION, 080450 3835 HARLANST Health care kitchen. ISSUED; EXPIRES; 05/09/2008 n/OS/2008 *,** , owne;r sub sub sub CONTACTS ... 303/257-1705 303/628-7576 303/461-0760 303/2%-2999 'Mark Bedinger John A. Picucci Harold Rogers , I I I J 02-2481 02-0522 01-9993 Sandalwood Manor LlC ~icucci Electric, Irtc. Plumbing by George Rogers & Sons Inc. . - 'ARCEL INFO ZONE, CODE, SUEtDIVISION, , ** ,.,r, UA UA USE, BLOCK/LOT#, UA 0/ Perlld t Fee Plan Review Fee 'total Valuation Use Tax ~* TOTAL -- · 'it ESTIMAT D PROJECT VALUATION: FE S 810.~9 526.1'5 .bo i 864.pO 2, 201.~4 48,000.00 -"FEE SUMMARY -- ..' '-., 4~ . . r1?'~:reh:y certify that the a:etback distances proposed by this p~rmit application are aCCU4rafe, and do not vi!=>lateapplicable o~di~ances,rulesor regulations of the City ot Wheat Ridge or Icovenants, easements or restrictions ofrecQrd;~tal1 . ,~~,S\lrementsshown,and' allegations made are accurate; that I ~ave read and agree to ab1d~all conditionsprint'ed ()~'_th!~ ,application an~ that, I assume full responsibility for compliangewith th~ Wheat Ridge Bu~ldi~ Code (I.B.C) and all other a~l1cable Wheat Ridge Ordinances, for work under this permit. iPlans subject to field in:aJi,l!C_t-:on. I s~~ture of contractor/owner dat~ Thi. permit w.e iseued in .ccorQance with the provisiOns se~ forth in your .pplic.tion .nd is subject to the l.....,'~t~ s;ta,te of Colorao.o. and to. the zoning Regulations and BUildin~ Codes of Wheat Ridge, CO,lorado or any otherapplicat:de' -. _:;:~ :prd~nance8 Df the City., ... .. ,,' ~. <This permit shall expire,180 d&YI3 from the issue date\ Requ~sts for an extension must, be received prior to expiration date. An extenslonmay be granted at the discretion of the!BUildingOfficial. 3 If this permit expires, a nevi perm~t may be acquired for a tee of one-half the amount normally required. provided no e~ges have been or will be made in the original plans andispecifications and any s~~nsion or abandonment has not exceeded one (1) year. If changes have been or if suspenSi~n or abandonment exceeds one (1) year, full fees shall be paid fO,r a new permit. I 4 No work of any manner shall be dpnethat will change the natural flow of water causing ~ drainage problem. S Contractor shall nOtify the Building Inspector twenty-four (24) hours in advance for all insrections and shall receive written approval on i~spectioncard before proceeding'wi~ ~uccessive phasesoft~e,<~ob~ 6, The issu.nce of . permit or the .pprov.l of dr.wings and sp~cifications 'h~l1 no~ be ,co"strued to be a permit for ,not ~rt approval of, an . tionof the. provisions of the builfing codes or any other oriiirtance, laW', rule or regulation;,,: :,~ll plan revi i ect to ffBld inspections. I i signature of Chi . X#$l>ECTION REQUES'1'~INBI 'Rl!iQUESTS MUST BE MADE BY (303) 234-5933 3PM ANY BUSINESS dot. Ii" BU+LDING OFFICE, (303)235-2855 DAY I FOR INSPECTION THE FOLLOWING BUSINESS'DAY. . /dt9i-d~ff"l\A. ,.. 0 ~. ,rJ Y /2>~ .d~~9'A9~ ,/"/Ht"~ , .. INSPECTION RECORD loccupancv/Tvpe <rINSPECTION LINE: (303) 234:'5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING To THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR COMMENTS: INITIALS Footings/Caissons Stemwail / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines POUR No CONCRETE UNTIL ABOVE HAS BeEN SIGNED CONCRETE SLAB FLOOR Electricai (Underground) Plumbing (Underground) Heating (Underground) ~'7$' oS tk:- . I /yo. "I! ~t'av,.a> """ Do NOT POUR FLOOR UNTIL ABOVE HAS BeeN SIGNED ROUGHS Sheathing Lath / Wall tie Mid-Roof Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical Framing Insulation Drywail Screw "'..... ..tr!::c-.:;c.:: '-m4 Q., . ABOVE INSPECTIONS rOBE SIGNED PRIOR TO PROCEEDING I a FINALS Building Fin Fire Department R.OW & Drainage Parking & Landscaping "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICA TE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER Electrical Plumbing Mechanical Roof START ALL ROUTING ONE WEEK PRIOR TO FINAL INSPECTIONS. FOUND PIN &: CAP BURDICK - P .L.S. 9010 0.3' WEST OF PROPERTY CORNER FOUND PIN &; CAP BURDICK - P .L.S. 9010 0.35' NORTH AND 0.19' EAST OF PARCEL CORNER PROPERTY LINE L 379.74' .. NB9-S3'S9ttE ::~~::::::::::,,::::::::::::2 .::....:,.~............;..... .:..:...::............. ~ ~ ""~" . ~~.........~~............. .. " " " ... ..................... r I . I ;1 91.55 LF 4" PVC SS 45- 4" PVC BEND wi CLEANOUT INV=5404.80 N=15710.92 E=42995.71 EXistiNG WA TER SE~VICE AND MET~~ I TO.:.;.REMAIN :. INSTALL 6"X12" TAPPING : :v S~DDLE WITH WYE .". ; CQNNECTION ::::.: ,77.67 LF .~ '-'. I . '.' 6" PVC SS ~, ~ '\ I - T~ ~ \...... [. .:... . 1 ~ (. ..... ~. ~ RELdcA TE ~XISTl~G :.~. LIGHT POLE~ AND ELE9 BOX ;> ~ I cb~T ~OX I BASE MtNHOLE l- t ~I 'lilt u:i I'4j ~ a (0- LOO _ 0 (0. rO O~ o Z 70 LF 8" PVC DL ~1.0% MIN. WR DOUBLE VALLEY INLET GR A TE =541-o;47,,~'m ""I INV=5406.60 (8") INV==5406.50 (12") .................................................................................................,-_......................... .....""-""- 78.60' S89-S3'59"W PROPERTY LINE CJ) CJ) u > a.. "1 ; ~....~.;;..-ol""" ~~"~:~~:~:...::r: 4" PVC CLEA.N.QU"I"mmm.... ..".. INV=5405.16 c..u I N=15627.76 E=43022~69mm.. m a::: , WA TE~ QUALITY STRuctuRE ~. VORTI!CHS MODEL j " 7000..... 35098- 01 OR i: ~QUI~ALENT I I- W W Ct: I- (f) ~I I 10.00' I I I I I :: 'lilt La.. .....J o o ci LO ~' a _ (0 LOLO 0)- .(0 ~r ~O o Z z <( --.J Ct: <( .I 50.00' 5.4' S89-53' 40.W 48" I D MANHOLE Laj; . : . 0): ~ CO r. ....8 .. 11:.. .,. :- "'.. (J); WR CURB I (SINGLE) INV=5407. '- iNV=5407.48 (12") "'-~! .1:V~F DL...... ........-omm.m.m ] 45- 8" PVC BEND W/CLEANOUI nnnmn.m......m I INV=5407.80 N=15519.10 E=43016.37... ....m...m....m.] ...m............m ] 20 0 1 0 20 ~ I I ORIGINAL SCALE: 1 "=20' ..... 'OM:. PROPERTY LINE 12" LANDSCAPE DRAIN INV=5409.50 N=15460.69 E=42870.55 '. :..: "'45- 8" PVC BEND W/CLEANOUT INV=5408.46 N=15472.98 E=42970.33 EXIS11tl'G CABINET, LIGHT POLE{ AND TRANSFORMER TO REMAIN, PRpTECT THROUGHO~T CONSTRUCTION ~ S89-S3'21ltW .. .." .... .. .... ...11 ..... .... .. .... lO. .... ...... SOO-16' 53"E 7.00' 40 I SET NAIL &; TAG P.L.S. 34183 ........ ".:-ll"":.: .... ........ ..................... .......................... ... .. .. .. '.: .. ...: .................................................................. .. .. .. .. ".... .. .. .. "":: :~:... .... .. ".............. .. .. " ....,. " ".. ....................."............ .... .:'..': ...,,: ..................11............. ...... ......" .. .. .. ..: ........................................ ...... 38TH A VENUE B L ING fFlctAL . f permit or ....oval of plans' spdcItioM validity Of pe' --: T lSSU e 0; a me for Of an approval'" any Violation to and computatio shaH not be a ~. ~ Of of lAY City OfdinIRCtL MW of the p'cwitioftS of the bu~ eel....... pro-'- of.. ..... . . thOfitv to v'olat. or can U1W permits Pfesurrnfl9 to give au.J es Of the City Shall not be Wilde ..., , n",: f1ripc:; (,>thpr r-.rulfl3f\C " IBe SURVEYED ITEMS LEGEND c-o.., SANITARY SEWER LINE GAS LINE WATER LINE SANITARY SEWER MANHOLE CLEANOUT UTILITY POLE OVERHEAD UTILITIES WATER VALVE WATER METER GAS METER ELECTRIC METER CHAINLlNK FENCE WOOD FENCE LIGHT POLE TELEPHONE MANHOLE WATER MANHOLE SIGN INGRESS/EGRESS - CURB CUT SET PIN & CAP P,L.S. 34183 FOUND NAIL & TAG P.L.S. 9010 UTILITY PEDESTAL CONCRETE ELECTRICAL TRANSFORMER TOP OF CONCRETE FLOWLINE OF 6" CURB GROUND SHOT TOP OF WALL BOTTOM OF WALL ASPHAL T ~~) PROPOSED ITEMS LEGEND PROPOSED STORM SEWER 12" NDS LANDSCAPE DRAIN PROPOSED CLEAN-OUT COPPER WA TER SERVICE pve STORM DRAIN pve SANITARY SERVICE II jJ WS DL SS NOTES: 1. 4U PVC SEWER LINES SHALL BE INSTALLED WITH A 2.0% SLOPE. 2. 6" PVC SEWER LINES SHALL INSTALLED WITH A 1.0% SLOPE. ON SITE PLANS MUST ON SITE FOR IN ECTION APPROVED Subject to Field Inspections Wheat Ridge Building Dept. BENCHMARK: CITY OF WHEA TRIDGE BENCHMARK POINT #5909 BEING A BRASS CAP AT THE SOUTHEAST CORNER OF THE SOUTHEAST QUARTER OF SECTION 24, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH P.M., ELEVATION = 5415.97 (DATUM = NGVD29). PROJECT MANAGEMENT · CIVIL ENGINEERING PLANNING - LANDSCAPE ARCHITECTURE 333 West Colfax Avenue #500 Denver, Colorado 80204 Office 303/825-7475 Fax 303/825-7341 MH MARK HOSKIN ARCHITECTS 1732 WAZEE STREET SUITE 201 DENVER, COLORADO 80202 TEL: 303.298.0755 FAX: 303.298.0934 0:: 0 Z <( ~ 0 J-O W~ 0 Wo a::....J J-o 0 cn() z 0 <( - ....JW a::(!) ~ <(Q I~ LOJ- ---I Ct)<( coW <( Ct)I 3: 0 Z <( en JOB: DRAWN: CHECKED: DATE: 08-072-01 WPM JMP 03-24-08 SHEET TITLE: OVERALL UTILITY PLAN REVISIONS: SCHEMATIC DESIGN DESIGN REVIEW DESIGN REVIEW PRELIMINARY PRICING CDS C-05 BELFAY ENGINEERING Mechanical & Electrical Consulting Engineers 2811 Wesl9th Ave. TEL: (303) 892-5980 Denver, CO 80204 FAX: (303) 892-5979 email: belfay@belfay.com Plumbing By George 11901 W. 82nd Ave. Arvada, CO 80005 Att. Mike Hoffsetz Re: Sandalwood Manor Drainage Count Dear Mike, We counted the drainage fixture units for the existing building and the new addition. The total fixture count is 430 drainage fixture units. A 6" sanitary sewer drain size will be adequate for this number of fixture units per table 710.1 of the IPC. Please let me know if you have any questions. Sincerely, Brett Wixson (xIOI) ~~~ APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date: Plan checker Signed: 1...r:S SANDALWOOD MANOR 3835 HARLAN STREET WHEATRIDGE, COLORADO .. ~ CIJ.; ~ c: 0. .1::0 o Q) 'is 0 Q) Cl 00. c: ~ ~ :2 032 ~ ~~ Q) 0.0 ~ c(~ a:: o ... .!!!, 111 .Q Q)2'VTR ONN~ VE,m; MIN. F 42" ABOV?GRAO&i "" - III o GI FROM KITCHEN ~ ACTIVI TY ROOM F-==4"G I 593 SF I o z REFERS TO: N/A OFFICE 122 SF J2"v r~I~------ rr-:J._______ ..J'i-----li- II II INLET II II c.o. I II I II l I 254 SF I I .L_____JL_ '-'-------- --..., I TO SANITARV lAAIN ::;l \EE CIVIL DRAWINGS II I SHEET C-05 II I I~ I 4"Ssoo-f I OUTLET I C.O. II ~ 1000 GALLON GREASE INTERCEP OR \\\ \\ \ \ \ \ \ \II i I~ Ii ~!f I it lit \\" ..Il" Ilt,. !", 'I- .:- "?...\'\ u . ')/p"~' l~~~. ~(r[~~z:s:;~.,;:~j; :::;'-">~~~ (',,~,'- ~ i~? \~~~ ::" ~~~l_' 22785 rn: ~- :2:.\, . c: INTERCEPTOR LAN SCALE 1/4" " 0" ENGINEERING BV: , BELFAY J...... ENGINEERING ~ ~" 2811 WEST 9TH AVE. ~1- DENVER, CO 80204 ~ J (303) 892-5980 '" T ~ ~AX: 892-5979 -,....- belfoy@belfoy.com 08045 08045P JS BW JOBH FILE ENG.'ED BY CHECKED 8V 105/05/08 @ COPYRIGHT 2008 THIS DOCUMENT INCLUSIVE Of' THE IDEAS INCORPORATED HEREIN IS THE PROPERTY or BELFAY ENGINEERING. Nrr USE Of THIS OOCUUENT OR ~ WITHOUT THE WRITTEN CONSENT Of BELFAY ENGINEERING IS PROHIBITED. SHEET 1 OF 2 I DESCRIPTION: GREASE INTERCEPTOR DRAWING ~ I/) c: o +:; o Q) 00. w'" >E 032 D::<J:> a..u.. a.. 0 c(- - o Q) z; :l en TYPICAL GREASE TRAP SECTION ...: 0. Q) o Cl c: :2 '5 CO Q) Cl "C a: .. ~ o lD .I:: o c: III a: SCALE NONE ," .... 2.. x 2.. x.- C<JNCA[1[ ... " ounrr ,,\"\ \,,~" ~~' iO~' '').' i,~ I 1/ "~,,. ~"qj Jtbt:-'- ;<~~~::';,-:' 6\~LZ~~ ~:t,:'~_'. ~'C;,:,cQ \. :A.,. _j; ~-'-.:~:;0 \t:7~; '.-, 22795 m.:.::c o l~.i I; '08 .'~~"'_: .,.>;,"(.~~\$~>' SANDALWOOD MANOR ENGINEERING BV: JOB# 08045 ~ BELFAY FILE 08045P "'- ENGINEERING ENG.'ED BY JS 3835 HARLAN STREET ~>> 2811 WEST 9TH AVE. CHECKED BV BW WHEATRIDGE, COLORADO ~ DENVER, CO 80204 . ~ P03) 892-5980 @COPYRIGHT 2008 AX: 892-5979 THIS OOCULlENT INCLUSIVE Of THE REFERS TO: N/A ~ belfoy@belfoy.com IDEAS lNCORPORATtO HEREIN IS THE PROPERTY Of BfHAY ENGINEERING. 105/05/08 AKr USE OF THIS DOC\J"'EHT OR lOEAS SHEET 2 OF 2 I DESCRIPTION: GREASE INTERCEPTOR DETAIL WITHOUT THE WRITTEN CONSENT Of BElFAY ENGINEERING IS PROHIBITED. .! III o i::i Q) c: Cl (j) 1YPICAL DIMENSIONS SOl( GO. . . C D ...... "" "" ,," n" ,." .." "'" ,," .." ,," ,." .." toO ,r .." "" "," .." '000 "" n" JO" ,." 7'" "50 .,' n" JO' .." ,.' '''''' ,," n" JO' 50" ,." 2000 ,," .." .." 00" ,." """ 00' 110. "" .." ..' WIDTH IS INSU nEAR OUENSION. ~ .?' Wheat Ridge Sanitation District 7100 W. 44th Ave. #104 P.O. Box 288 Wheat Ridge, Colorado 80034-0288 FAX: 303-424-2280 Phone: 303-424-7252 May 6, 2008 Plumbing by George, Ltd. 1190 1 West 82nd Avenue Arvada, Colorado 80005 Re: Grease Interceptor Sandalwood Manor 3835 Harlan Street Wheat Ridge, Colorado 80033 Dear Mr. George Hoffsetz, The District Engineer has reviewed your submitted documents for installing a grease interceptor at the above property. The information provided appears to meet the District Rules and Regulations for grease interceptors, with the following comments. I. The District recommends using two 450 fittings instead of a 900 bend on service lines outside of the building. 2. The grease interceptor shall comply with the attached detail, however, the sample port may be omitted. 3. The service line into Harlan Street shall be a minimum of 18" below the water mam. Please contact the City of Wheat Ridge to obtain appropriate permits and approvals prior to construction. Notify Wheat Ridge Sanitation District (303-424-7252) within 48 hours of backfill for inspection by their representative. If you have any questions or need additional information, please call me at 303-431- 6100. Sincerely, William A. Raatz District Engineer Wheat Ridge Sanitation District TYPICAL GREASE INTERCEPTOR AND SAMPLE PORT INST ALLA TION 2 3 t 15 mJ. ! 6 . ~ t ls 12 13 \4 18" SIDE VIEW 1. Influent Line 2. Vents 3. Minimum 24 inch opening with a ring and lid. 4. Primary chamber inlet piping (Must extend I foot below the operating level) 5. Primary chamber outlet piping (Must extend I foot below the operating level) 6. Secondary chamber inlet piping (Must extend I foot below the operating level) 7. Secondary chamber outlet piping (Must be extended 18 from the bottom oflhe chamber) 8. Grease interceptor discharge line 9. Sample port (minimum 10 inch diameter, provide at least a 6 inch vertical drop for the grease interceptor discharge) 10. Sample port ring and lid II. Sample port discharge line to the sewer. 12. Primary chamber 13. Secondary chamber 14. Baffle (must be sealed) 15. Grease interceptor operating level NOTE: I. All wastewaler except restroom waste must flow through sample port. 2. The sample port cannot hold water. Date: April 28, 2008 Plumbing by George, Ltd. 11901 West 82nd Ave. Arvada, Colorado 80005 Telephone (303) 717-2281 Fax (303) 463-0952 Martin / Martin Consulting Engineers 12499 W. Colfax Ave. Lakewood, Colorado 80215 303-431-6100 303-431-4028 fax Attention: William A. Raatz, PE Concerning the Sandalwood Job - 38th & Harlan ;;"Po ~e. 1: /<..~~ "<,,,,,,,,,.1 k.. As per our meeting, Plumbing by George, Ltd. will be installing a 1000 gal. grease interceplor in a straight line. The garbage disposal and all other drain lines, in the kitchen, will run into the grease interceptor. Plumbing by George, Ltd. will take the line outside and straight into the main line in the street. The line will be upsized to 6" in order to handle the new addition as per plans. The bed count will be 105 at about 90% capacity at all times; following the new addition. Thank you, George Hoffsetz President 303 463-0951 COMMUNITY DEVELOPMENT DEPA TMENT BUILDING INSPECTION LINE - (30 -234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-23 -2855) Building Permit Number: 16544 Date: 12/5/2003 Property Owner: SANDALWOOD M NOR Property Address: 3835 HARLAN ST Contractor License No. : 20194 Company: Greiner Electric LL Phone: Phone: 303-470-9702 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDI G AND AGREEMENT (OWNER)(CONTRACTOR) SIGN Total: $17,862.00 $381 ,30 $0,00 $214,34 $595,64 I hereby certify that the setback distances proposed by this permit ap Iication are accurate, and do not violate applicable ordinances, rules or regulations of the City f Wheat Ridge or covenants, easements or restrictions of record; that all measurement shown, and allegations made are accurate; that I have read and agre . e by all conditi ns printed on this application, and that I assume full responsibili kJr: mpliance with e Wheat Ridge Building Code (U.B.C.) and all other applicable W Ri ge ordin'f'Ces, fot ark under this permit. /' ~ DATE r. Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: 1f~~L~ Description: ELECTRICAL INSTALLATION FO FIRE ALARM SYSTEM UPGRADE BUILDING 0 PARTMENT USE ONLY - -'nt0li -.o!.g '1..www,e" I. Approval: Zoning: I'iJIDXilng:;emmnei1~ Approval: .c;;W~d~: Approval: SIC: Sq, Ft Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : 20194 Company :Greiner Electric LLC Expiration Date: 2/28/2005 Approval: OK/KS Plumbing Lice se No : Company: Mechanical License No : Company: Expiration Oat Approval: Expiration Date: Approval: (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject 10 the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any nth r applicable ordinances of the City, This permit shall expire if (A) the work authorized is not commenced ithin sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days If this permit expires, a new permit may be acquired for a fee of one- alf the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonme t has not exceeded one (1) year, If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flo of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours i advance for all inspections and shall receive written approval on inspection card before proceediin ith successive phases of the job, . Th i nC'mf a er~' rthe approval of drawings and specificati ns shall not be construed to be a permit for, nor an approval of, any violation of the provi ns th codes or any other ordinance, law. rule or r gulation. , ~- Chief Building IUpector I Please sign Terms and ~onditions on reverse side of page. (4) (5) (6) 0' ~H'4r COMMUNITY DEVELOPMENT DEPARTMENT ~~'b BUILDING INSPECTION LINE - (303.234.5933) u ~ CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE oO(OR'OO WHEAT RIDGE, CO 80033. (303.235.2855) Building Permit Number: Dale: APPLlCA TlON ~' AI1 Property Owner: --=+4A::l~ I..-LJ DD.:D ,V l...:\-W "-' 12..-. Property Address: 3> '0 -"" S' 1-+"" i2-L-A,.j s-r- Contractor License No,: Company: G n r ^' ~ () ( ~ "I'-"'-I 'v u'- cL.Cc-,"",-, c Phone: Phone: 3D3 '--\ ~ D q ?- 0L OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate: that I have read and agree to abide by all conditions printed on this apPlicatio. n a~that assume full res~~ibility for compliance with the Whea. I Ridge Building Code (U.B.C) and all other a~ heal Ridge Ordinances, for work under this permit, . . (' h (OWNER)(CONTRACTOR)'SIGN~ . .- DATEfI;li:/a<; 0) , Construction Value: $ Permit Fee: $ Plan Review Fee: $ Use Tax: $ 1+ BbL'<d , (OWNERIICONTRACTORj PRINTED DATE Total Fee: $ DESCRIPTION: E",._,J,_~, 1-,c~LL'~~~-' 1;.Q ~,,~ A () C {In IJA,>-L ~_.'T>- ~~ ~v~,~ ,"U'~ ;-~ '~r-:- rrLA,v'4, J'1<;'~~ ,UG"-fP;>C BUILDING DEPARTMENT USE ONLY SIC: SqH: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof' Stories: Residential Units: Plumbing License No: Company: Mechanical License No: Company: Electrical License No: Company: c'ilINU [<-.E c~ c. Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) Tllls penntl WI' 'SlUed in accordance wtth the provlllonl let forth In your appltcation and is subject to the lIws of the Statt of Colorado and to the Zoning Regulation. and BulkJing Cod.. of Wheat Ridge, Colorado or any other IpplIClble ordinance. of the City. (2) This permit ,hili upire if (A) the wort .uthorized I, not commenced within sixty (60) day. from Issue date 01 (8) the building authorized i. suspended or abandoned for I period of 120 d.ys. (3) If this permit expires, I new pennit mlY be acquired fOf' . fee of on.half the .mount normally required, provided no changes hIVe been or win b. mad. In tile original plans and lpec:ffication. and any suspension CI( abandonment h.. not exceeded one (1) year. If changel h.ve been or if IUlpefltion 0( .b.ndonment exCeedl one (1) Yelr, full f..shaU be pakI for. new permit. (4) No wort of any INIMer IhlD be done that will change the natural flow of wlter Clullng a drainage problem. (5) Contractor shal notify the Building Inspector twenty.four (24) hours in advlnce for III inspections and shaH receive written IpprOVal on inspection card before proceeding with succnslve ph...s of the job. (6) Thels.uance of I permit or the approval of drawings.nd specifications shall not be construed to be . pennit for, nor an approval of, any violation of the provisions of the bulldtng codes or any other ordinance,l.w, role Of regulation. Chief Building Inspector . ~i f k ff ii,.' lfl 1\"" " II '{1 ""heat Ridge Fire Protection District P.O. BOx 507 .3880 Upham Street. Wheat Ridge, Colorado 80034-0507 303-403-5900 Office . 303-940-0350 Fax . www.wrfire.org Pennit No. ApplIcatIon .Dal:ll: -' '..., ""'; - '", f i ; , k cO~...tftr~tioft SIte Infol1l'lltion .... t t.~ .... F~: ~, \:'.' . ''',-'-' 'Name; . . . Agent;, Addn!s5: Address: ~ .0;, L.,,' ..." ~ .~ I,.,-.~.> _:. : ~....,., 'i''\~~ .j',,,'...' ~ L \'" "". Business: Contact; Phone; ",--" I,: \ ':(;.'" t "..- ,"" f;~ >,~ ''i >:. Phone: .':v -''1 ,,' '.-:,":~" ';;"",:~ L;:,. ~;, ' ~ :r: m > .... :a .... C 1 ........ ~...;~I~~.ot..,lD be_ 1 have _ ODd ...-- the 1nIpe_ Compllonce ODd the Fee SdleduI.. 1IlIs permit 1$ the ~ .~q..,~~.tiPt..'~..!'~,.IIr1lP,>..;::l'~~~~...bjeetim=-..~:..lnod~.Upon_~~~~ldIII=.,"1llI m . or' " ... l\n, permit payment..... D subject lD Ie.."" iUIiI the _It must be .w.._ _ ". lD. 1....~..ofthe~IlIdIeFlTu~D_ ." --, >';""',,,,'''';''''';<''',r'',;,''':'"'''''''-'''-' .,:"~";,,,:--,,,, .', ",'''. ".,,,,.-..,-- --"''''','''', ,,"<>'," ""-,,,-,,,,,,,, "",,", ,', 'a' :a o ..., .... .,.;1 ,j >"': - ..~.. ... "" " ~~~1i\W; ...,.-;"'; ~. :'. ,: ~:~ ,'" ~..;~~.."~,- t'~\\';!f::":"i"""'{>"i;""i""'; :i' ..." No':::~. of~FEESJ)UE (:\~'\~~~;~At:~~;..; :::-;'>-""" t ." " .,' BY ,," , TInE DATE t.;.>,.>~,:_:,c'..:~:~~,,;<,>~_ d.' > ,', ' -.' '.' ,... ...., '" ..., , . " , ii'":;,;~0-,~i;iliijf;~~i1&~tl~;.j0..~t~~:~~i~;k:L'Li.i::;i<~U;"";1,'~~.~.,j;f:dJ:"",d&''''':;-~t.Jci:~~~~l;6;~,'!i~1,~"_,.l'j,,-'';7,-''''':',,,''~,"" \-.":"""';"'-" ';;., , _~ ~~~~__;_~~'~ _~~~'"-'~~~I~~~iit~!~~; $>. ~i' fft:: t ~~":',: ~i NDnceIf ClIIIStruCtlon is started prior to the Issuance of a pennit. THREE (l) times the normal fee will be assessed. ~4" ~,:" '-'''' ",' I~, . ~;'" ~".' k. ~".<, ~;':" .- ~,~ ~~ . t ~::Y" SIgnature of Applicant: />.>t,,~,/,' , ," .(" ,~~..- , ~,"" fe,:';'- ~,,.~f'W'~~p~g~? "YES. 0 NO. 1'rM:t,,!,,,Jief"'!/In.~~p/l/t:e. ~""IuIn!!d.~"m/nimum of/flteedayslnl1tlttan(eiJtJOHOH902. FEES FORMUlA {....---t , NO.ofTankso= , ~V.alue.",,,,,. System Value= Sy!;leln Value.., ' Valuation.. ;,Y -f.iooW,""oo...;~ ~,~ OalePaid t Ant. Paid Inillals lOYAL FEES DUE "' -4. o Tata! Bldg. . ,. ',,. .o~.,.~" Field II~lS "lid DaIest, , " o Alteration o Partial IU Other: AI ,. 0(" <.. ,.1- ~ w .... ~.. '('ll..<~.... ~",T. ~. ~, k ~:-;, , tiyd!Wtatlc Testsalld~; -'.c"" '....'". :,__",..9?fI\~tnts:;""-~""',lir "W1flh....-h F L: E~-:,':E:::~;:~:?,:,~:,~0~:~'~:::;E~i,?'~:':.'L~..:"':~'::~.,,~.::::'.,'.::~:,~,":;'::' , J:.i,f~,i~;,~ .. 'I", ~~~: ", _-,," ,,,j::;',!~~),(;~~:;::'",'\::,<:',,,, ...... ... ... . . ...... ., , ~;p&nucT ~A1.lSREQUlRED PRIOR TO THE ISSUANCE OF THIS PERMIT. :' '" >"0:':"""'" 'AS~ y AI'PROVB> (See Comments.) ~,;,:,,,:,,,,-\,,, ,:,.,",/" -,"':,''-';--,\;,,,-., )'".- .:' -',' . : ~ -J:,.", , TInE f.-i(,(Ji(IIl'.JilI4L DATE J Z~ 1~o3 fEES "Ii, Ant. Paid MefJof' '::", Inillals. ,,,;,,'.; ",.",.',,,", ." .... :a m n .... .... o z c .... (n ... ';11:1' .... n .... >'~ '. .,'", ''(f>:;;:: " m~'" .,:a,,,,,,,.,,,, Z ~ ....' / 112(.0:' Permit No. "lication Date: 116f.1 Wheat Ridge Fire Protection District P.O. Box 507 . 3880 Upham Street . Wheat Ridge, <;olorado 80034-0507 303-403-5900 Office . 303-940-0350 Fax . www.wrfire.org , Name: Agent: Address: Contractor Information U)'~~-'Y-\ -C r ::: ;,',') I k 'S \ tr, c, ,__-, Address: Site Information 3' A 3'~ lb. f2.LA..P ~.- C,.....IA.,y_\II' r(,~'; c.c" COv........)J. .$/l.J E!~ l (drO~ -4 M.~7Jii'i =e :J: m 3> -f C I attest the above information to be accurate. I have received and reviewed the Inspection Compliance and the Fee Schedule. This permit is the C) property of the Wheat Ridge Fire Protection District and is issued subject to conditions contained herein. Upon any failure of any condition including m failure of clearance of any permit payment, this permit is subject to immediate revocation and the permit must be returned upon demand to a representative of the Wheat Ridge Fire Protection District. 1_, ,_ {"- 1'-1--:: I~ ;_e.J C 4_....6...~:" G,..-Ic'i, .-, (y '~'.'.../...) I \ '"":. '2.7 '\ c:.( ';?;>Q'..;:, Business: Contact: Phone: ;:a 104 Phone: Signature of Applicant: /~L./J ,. . /.i y~-~ ." 104 NOTICE: If construction is started prior to the issuance of a permit, THREE (3) times the normal fee will be assessed. ;:a INSPECTION BY ARE PROTECTION DISTRICT REQUIRED? W YES D NO m Post this pennit in a conspicuous place. Request required inspections a minimum of three days in advance at 303-403-5902. TYPE OF PERMIT FORMULA (see fee schedule sheet) FEES Tank Inspection No. of Tanks ,I X Review Alarm System Plans System Value- ,fry;:; 'I en '0 ",-0 1'72(.1 ",,, Review Sprinkler System Plans System Value- Review Misc. System Plans System Value Review Building Plans Valuation- Special Handling or Use Plans Valuation- .., I TOTAL FEES DUE J'11'l?, tJv D Total Bldg. D New D Alteration D Partial Date Paid Amt. Paid Method Initials " ;:a o I - -0 -f ,()o+s--;-''''m c",'" Vi CMII n 1<-. -f 104 o Z ~ Other: I' / . . - Field Inspections and Dates: . ./1 I".I~.Ilt':.L.. "J"l.J4~_ . Hydrostatic Tests and Dates: Comments: ~ "'". ('nu'....~.-t~ r, u PI A /J 5. . C 104 Ul -f ;:a FIRE PROTECTION DISTRICT APPROVAL IS REQUIRED PRIOR TO THE ISSUANCE OF THIS PERMIT. D APPROVED AS SUBMffiED 't!'CONDmONALLY APPROVED (See Comments.) BY7"AIJk I?nbert.-A TITLE h~;fJlA!tttJftJL. DATE J 2-::2-03 ~ 104 n -f TYPE OF PERMIT FORMULA (see fee schedule sheet) FEES Site Assessment (Re-Submittal) No. of Sites Plan Revision (Re-Inspect) No. of Hours After hours inspection 2 Hours + No. of Hours I TOTAL FEES DUE Date Paid Amt. Paid Method Initials " m ;:a 3: FINAL APPROVAL BY :;p Gl&'~ tZ. '" u "b /'" 104 -f /" TITLE/7,u;;A:IJ4-teJiH!L DATE I-AE-pI{ ~"",,,,,,~~.~.I~~ll;~If!~~H.,,,~,,,,,,,,,..,,,,~..Jl!~,""!I!':!i!l.!I,JJ.~,,~,II.lIll~."~Mi'k~lJl!~'llJ'~;,.l.'fll!~'!lll.1I!!llJ~.I!1I\'I~JIIlI.II.II!IJ.I:"",~'!Jl!!llijl"'~ t' ,.J DEPARTMENT OF PLANNING AND DEV~LbpMENT Building Permit Number: 6929 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 4/22/98 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: 3835 harlan st Contractor License No.: 18057 Company: Modelco Electric Phone: Phone : 451 6236 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the satback distances proposed by this penntt appllcetion are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that al asure ts shown. and allegations made are accurate; that I have read and agree to all ion$ printed on this application, and that I assume full responsibir co lIa I the :Whe Building Code (U.B.C.) and all other applicable Wheat tlge ce r w er this penntt. (OWNER)(CONTRACTOR) SIGNED DATE If,..z. <'"" Total: $220.00 $25.00 $0.00 $3.30 $28.30 Construction Value : Permit Fee: Plan Review Fee: Use Tax: Use: Description: ELECTRIC ON SWAMP COOLER BUILDING DEPARTMENT USE ONLY SIC: Sq. Ft.: Approval : Occupancy: Walls: Roof: Stories : Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date : Approval : Expiration Date: Approval : Expiration Date: Approval : (1) This permit was Issued in accordance with the provisions set forth in YOpOr application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Rldpe, Colorado Of any other applicable ordinances of the City. (2) This permit shall expire ff (A) the work authonzed is not commenced withln sixty (60) days from Issue date or (B) the building authorized is suspended or abandoned for a period of 1~O days. : (3) If this permit expires. a new permit may be acquired for a fee of one-half'the amount normally required, provided no changes have been or will be made in the original plans and specificatiOns and any suspension or abandonment h~s not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, fun fees shall be paid for a new permit. 145) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. ) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceedling with .uccessive ph.... of the job. (6) The issuance of a permit or the approval of drawings and spec/flcations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building es or ny other ordinance. law, rule or regulation. Chie uilding Ins THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: //-2 A /!-9-- 7500 WEST 29TH AVENUE y v--r 0 WHEAT RIDGE, CO 80215 , t Property Owner: 5n-IAA Ie tptJ()C( ~1T/1.11 Property Address: '3?"%-5 (<1ITf( l/n'v S /; Phone: Contractor License No. : ( g Cf 7,{ 7 Company: '}v0/LI LO r:;WtZl C Phone: Lf5/-i23{ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: ;J..J.o -- I hereby certify that the setback distances proposed by this pennit application are accurate, and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; tha II measurements shown. and allegations made are accurate; that I have read and agree to a de by nditions printed on this application, and that I assume full responsibility fa om with the Wheat Ridge Building Code (V.B.C.) and all other applicable Whe Rid eo s, for work under this permit. ~. DATE t;. UJoM Description: ;)W, Total: (OWNER)(CONTRACTOR) SIGNED BUILDING DEPARTMENT USE ONLY Z6hl11]'J;()~ Approval: Zoning: Bmrdlng:C!lmmen~ Approval: RlIDliClWJ5fKs~omm!l!)~ Approval: Occupancy: Walls: SIC: Sq, Ft: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: PlI ~!!ffSlR~~._ Expiration Date: Approval: II lP.LifIl!1ij!!ql!![!I5I- Expiration Date: Approval: . ~Dm!1f.1:f1__ 14) 5) (6) This permit was Issued In accordance with the provisions set forth in yopur application and Is subiect to the laws of the State of Colorado and to the Zoning Regulations and Building Code of lNheal Ridge. Colorado or any other applicable ordinanees of the City. This permit shall expire if (A) the work authonzed is not commenced within sixty (60) days from issue dale or (B) the building authorized Is suspended or abandoned, for a period of 120 days. It thiS permit expires. a new pennlt may be acquired for a fee of one-half the amount normally required. provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment excee<ls one (1) year. full fees shall be paid for a new permil No wort. of any manner shall be done thai will change the natural now of waler causing a drainage problem. Contractor shall notify the Building Inspector twenty.four (24) hours in advance for all Inspections and shall receive written approval on inspection card before proceed ling Wltf'l successive phases ot the/'ob. The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of Ihe bU62n~0lher omonanee, law, rule or reoulaUon, Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION (') (2) (3) d~""""",\,:,%,r'-''''_.-..;i "":'".- " , r Building Permit Number: 6951 Date: 4/26/98 " Property Owner: Property Address: 3835 Harlan Street Contractor License No.: 18464 COmpany: B, & F Heating & AlC , OWNERIC~~'t6~s~A"URE OF UNDERSTANDING AND AGREEMENT . ........ .... I I hereby 08,.=,.,"', '... ~c;kdl8lances, pmposed, I1Y lhIapennilaPPIlJauon are accurate, ane! d9,l\Qt~,"'~ '. 'Old, fnanON, ,ru-. or regul8lion. of the Cily~ofWheal Ridge or covenanta'~ll! Jitalri<:lIon$Of r8/:l>I1I: lila' au measurements $ own. and a~ made a(e.~ lII8llftavellilld,nd ~'" abIcI& ,II condmo r1nted on this applicatiq!lj8n4l1\~l~ fUllraponslblllll fOr co ncewllh the ealRldge BIIRdlng CQde(U.B.C.).llIIdlher sppllCiibl8 ~'"\{Idge 0:08.. for wo under thl. pennft. Phone: Phone: 431 8914 , ConstructiOn Value: Permit Fee : Plan Review Fee : Use Tax : Total: $2,400.00 $75.50 , $0.00 $0.00 $75.50 (OWNER)(C~OR) SIGNED DATE Use: DescriptiOn: Install a 6800 CRM evap cooler BUILDING DEP RTMENT USE ONLY SIC: Sq. Ft. : ApprOval: Occupancy : Walls: Roof: Stones : Residential Units : Electrieal License No : Company: I Plumbing LicenSE! No : Company: Mechanical Ucense No : Company: expiratiOn Date : Approval: Expiration Date: Approval: Expiration Date : Approval: (1) ==r1S'::t5~~::""c:=,":=:'ra ~=~bJ::b'~llleIawaOfll1e~cf~anct\O~Zonlng (2) ':=8l)1li ~., (A;,lIl1oWcllt<~ Is nO! commenced sbdy (eO) dayslrornl88ue dolo 0< (B) llle bIMng _Is SUSpended 0< for a peiIocI,Of tlO= I ' (3) 1I,1I>1s j)O(mIt ~ . _ 0I0y " acqulreclfor a fee 01 one-hallllle amount nonnally requlNd, _ no changol$ _ -. o<wtII be mode In llle QItgInoI """", ,aildoPacl, ,~ anctany_, orol>andonment jS notexceadedone (l)yesr, llchangol$a.._ or lI_sklnor abandOnment exCood4i.....l1l_fullfilas 0h0lI bepold tOr a -_ NoWcllt<'or anv- _ be donOlhalwlll changlllle __ wator ....Ing "dralnaga problem. ~_nQl!fy1lle,BuiIdIrio'_, 'IWon~ur (24) hours In """"""" for all fnspOcllona and _.-ve_ applOYII on Inapeetionc:onl_ ~.,:~:~~ ond apeciflcaIIons ~II not be __ to be" parmIlfor, nor an applOYII 01. any_ 0I1he "",,"sklns oIlI1ollUlldlng eodOS or any _ OIdInanco, law. rule or '"II_on, ! I I CIir:::~::~SVALI~ ~~iI:~:~:~~~:M~J:~~~,:~gV:so,~g=l!CTOR AND MAYOR ! I . i ul;;r""" 1"'~I't. ur r-1-I4.....'t.AU "'AU UCVCLUt"'MCN I BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 tlUuolng l"'errrlJt Number: Date: Property Owner: Property Address: Contractor License No, : Company: b~w",cd -fYbVWl 3<:6?:'~ ~V\. At I g: L\ \.D '-\ 1&+ j- ~-tI"'d- Phone: Phone: 43i-89/lj OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: ~ <too . 0(:) Permit Fee :1"5. ~ D I hereby cenlfy that the setback distances proposed by this permit application are accurate. and do not Violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants. easements or restnctions of record: that all measurements shown. ana allegations made are accurate: that I have read and agree to abide by all conditions pnnled on this application. ana tnat I assume full responstbllily for compliance With the Wheat RIdge Building Codo (U,8,C,) ana all athor apPilcablo~at ~id90 ordinances, for ~r1t undor thIS ~rmlt IOWNERl(CONTRACTOR) SIGNE'EL Il' L rfi. me:: c (~ATE y. J,';/o/CJ'(( Use Tax: G- Dt.).I/(J Total: <'5,'50 Description: \.~~ Q La 800 CFM j c..o~ BUILDING DEPARTMENT USE ONLY J";Jl .~.'" .;. Approval: Zoning: '''' '!'-~'Jjl.J.MJ.lo.Jc Approval: fltQbJlcYIa". kI_CulllnnetlB:'! Approval: Occupancy: Walls: Roof: Stories: Residential Units : Electrical License No ' Company: Plumbing License No : Company' Mechanical License No : Company: Expiration Date: Approvai : 3 (p"liS~ull'iid~ Expiration Date : Approval: II, Pllha RiRlulred;~ ':1 Expiration Date: Approval : . ~....ll..~:'~ -.~" (1) 12) (3) This !)erml1 was lssuea In accon:lance WIth the provlllons set foM In yopur appllClltlon and II sublect to the IawI of the State of Cobrado and co Che Zoning Regulations anCl BUlldl"9 Code of \Nh..t Ridge. Colorado or any other applicable ora_nances of the City. This permit snail expIre If (A) the WOnl; authonzecll$ nOl commenoea wltt'lI" SIXty (60) days from ISSue date or (8) the building authol1zea is suspended or abandonecl for a pel'lOCl of 120 daYI. If ltus permit eXPires. a new ,penTut may be acquired for a fee of one-half the amount nOrmll1y reqUired. PI'OVld8d no chlnge. have been or will be tnIde in the OnOINlI Dtanl and se>eaficauons and any suspenSIOn or abandonment hi' not exceeded one (1) ylar. If chIngeIare made or if SUspenSIOn or IbandonmInt exceeas one (1) year. full fees shan be paid for a new Qermrt. No work 01 any manner snail be done tnat Will cI'1ange tne natural flow of water cauSlnQ a drainage problem. Contractor snatl notify the Budding Inspector twenty-tour (24) hours In aav.nee lor aU Insped!Ons and shall recewe written approval on inspediOn caru before proceeollng WIth SUcceSSive pnases of the lob. The Issuance of a permit or the approval of draWings and specrfications shall not be construed to be a permit for. nor an approval of. any viola1iOl'l at the PfOViIiOns 01 tne bUllclng codes or any other ordinance. law. rule or regulation. (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MA VOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION l' "',''''1,1';':':' "1':""';' ""', 'I.. ! ~:~T,g&:it=~=r~:~~~:~5ENT , ,CITY OF WHEAT RIDGE . 7500. WSST 28TH AVENUE ' .,.l/ffEATItIOOI..COAJ0215 ".;: -" \, '; .~ < ij')' ': " I Property OWner: Property Address: 3835 HARLAN ST Contractor Ucense No.: 19301 . Company: Aquila Construction. Inc. Building Permit NUmber: 4322 Date : 1219/96 . ,. " r ;--~'1 ' "-",,,"'c' "tit ~ , ~\ ie,,;," .Phone: Pholle: 988 5850 ~ ,',' ,... ....:', . -- ......... .. ' ' .';- OWNERlCO~Ofl SjGNATtI~OF UNDERSTANOtNGAND AaREIj;MENT ~:#11==.=j~~Cn~':e~~~=' . covenants, ea 0Ii IWlIicliOns of 18CORI; lhIIt 811 ~ "'own, and allagatlons ~_=;,lhatlllavt _ll/ld III abide all conclllopf Drinlad <In !hie Iicallon '1IlliIlJ......., fUll....' , lOIIIh -'Wheall~ll!ge e......... ~ (U.e:c.).jIIIIJ.p olIIafllPPllC8Dit .for~_lIfi patiii.... >'(.:,.. ':'ir},.)p',.. . r . I :; (QWNER)(CONTAACTOR) SIGNED DATE /.;y~/9b ~vatue. : 'Pemilt Fee : Plan Review Fee : USelax; ~i rotia.: l ~,~ $3O,ailo.oo $397.00 $0.00 ~.oo $7!7.00 Description : REROOF l' BtJl1..omaOEPARiMENTUSE oNly' SIC: Sq. Ft. : App/'oUI : Occupancy : Walls : Roof: Stories: ,Residentialllnltll : PlUmbing Licen~ No : COmpany: Mechanical license No : COmpany: Electrical LICense No : Company : ExpiratiQ/l Date: Approval: . Expiration Date : ApprovlII : . Expiration Date : Approval: . (1) ;!\::'~1=="1~-:~:....~....:~~ctt!1a_olillol$lale.<<~anci"'lIllI~ (2) . ~."'~llAl...WOIk ',' .1I.llClIcOt..t'IIIliOed lIIx\y(8O)dIIyIlromlssua._or(8)lIllIllIliIdIngl!Ull\QrlZectl8~or (3) ~_~":,y~i:~~~nol~,:;::(='w=::"m::;=~or~~~ l45) :'~~),,=...fuI=.:=aJ:'wlll=~naturalnc.ol_causlnga ~ ~ ) contl\IlQlllr-=:.=::r..c~T:rm~' (24)...... II) ~Ior" inaI>OCIlOn8and &hill _wdtlOn __ on InopOcIlOn cont_ ~ 'ola.~<< .'~~iondopec1flcatlollS$haI1 nolbeconstruedto be a pemillor, noran__or; any_ ollllllJllOVlalonl 91i.i:.iidlI _or ~'fW>or....-., : i~BuiIdlnglnspeQtOr THISPeRMrr VALlOONLYWHENSIQNEQ aY THE CHIEF SUIl.PING INSPl!CTOR AND MAYOR CALL:. 23.W933 24 !-lOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: Contractor License No. : Company: /J9"lla ((~, 7</c., cSa,J..d1. kJ=?\: ~."l. 3D:':; if{~- Phone: Phone: ;3 ? t - 5([ si) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application, and that I assume full responsi 'Iity for co rance ith the Wheat Ridge Building Code (U.B.C.) and all other applicable eat Ridge dinances, r work under this permit. (OWNER)(CONTRACTOR) SIGNED Description: 6. /UJ-O-;; DATE/~/"Iru, , Total: BUILDING DEPARTMENT USE ONLY Z.i?iiJllin<:;.liiffI1lJlllf!:l Approval: Zoning: ~t!llCflij,gtC-oliil'jfiji'its;1 Approval: Ptlbl~olfi1li8!:lts] Approval: Occupancy: Walls: SIC: Sq. Ft: r suCDO, "::.. I Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: ~ !l'~la~~.oc-~ Expiration Date: Approval: 1I11~1li'-1j~~~Jf!I!~ Expiration Date: Approval : ~ ire.!l\l!!IlJ!l[<rq!~l!JIJ!I (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject 10 the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge. Colorado or any other applicable ordinances of, the City. This permit shall expire If (A) the work authonzed IS not commenced within sixty (60) days from Issue date or (8) the building authorized is suspended or abandoned fOf a period of 120 days. If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year, If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours In advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the/cob, The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION ~t~i~II ""~"";"'..,.I!l ". 'o~ . 'ftJ~ ), -,,/;~~ ~f F}f~' ~W :,'''':'';''rT '''I :l; '" ~ o 3 'I' ~ ~, " ;. !;,-' ." N 0 ~ 0 " ~ ~ ~. ~ ~ 0> '" CD '< )> " ~ 0. a: 2 ~ r 0 '," I ~1 ,,-' i. -.::.,. ~ '- " :~ t,; ,i ",' ~, 'T.' -, 02 .. 0 ",,, -or nO> 0> ~ -'" .. <l> 5?.~ 00> " " " ~ <l> 0> 3 ~ 0> " 0. '< <l> (3 S- 3 5' <l> c m .. ~ 5' <l> o ~ ~ ~~ " <l> " !!'. c :09; 0:::) 0'" -91 ~ --);: o c :to '" Q' ~ ~ 0' " 0> ~ 0. 0> ~ <l> :l; ." r " 0 0 0 m :D 0 ::!: :D Gl 0 2 2 .... )> " .... m I r '" :D :D '" 0 :D )> " '" ~ 0 ::!:::!:'" .... <Jl .... (/) 0 0 )> 0 '" "".. " r " r :!! 0 :D ::l .... 3 0 " 0 a. QlI>> _. " :D --m .. ~ .... '" ~:D: is '" :l 2 <Jl >: a. a: ~ -, Gl :z CJl 0 "'0 c " _<tl(D :::II>> " c.- o QlCDg.;- C ro a. :D -, ::l c_ .... < 0.=-_<1) " -0 -, 3i 39::Y ~. 0 '" '< '" I>>::l (I) = CJl -, ::l ,<coQl<tl '" ^ 2 0 CTOO"Ul 0 -, ~ 8. ~ :;: ::l ., CD -, O(ll(l)~ ~ ", " 5' :to '" ::l eN.. +-' 0 " 'OO~ " ~::l3 r+ Q.S.;:;:g- 0 >: ...., 0'1O::l =: 0 .....s>>c9: c ., -::J3::l '" ~ a. 0"10 ro w c9.~g co CIl:::rQl::l 0 W <tl CD:;:! (1:1 ...., U< ~::::o.~ '0 (l)!!.O~ ::r: ~.Ql::J _ '" '" =al'O ~ -, ., .. 0. ~ ^ +-' 0. 00> '" ~"Q ::J ::l => ~"o. CD o.~o '< , (/) )> c r+ m 0.- 0 ...." 0 ., 0 m .. r+ ro :IJ ~ 3.~ ro '" D."" >: r+ <Jl o.~"O ~. CJl r+ .. ~ < ,,0 :0- ~<tl'O 0 W 0-0 C co "Om 3>; " r+ w ' 0. U< ~ a. 0 ~ _0_ ::r: .. 5' U '" o>m -, -, >; " .. 0 mo " < '" o3=. ro ::l -" - _-0. '" :::r'< :; ro (/) ">;0 => r+ ()':;s:l) r+ ., ;::;:7::1 '" ro '<_0. ro o::TO r+ _..~ " m c <l> 0. ~ 5' o ~ -0 rrl 2 o 2 '" n o 3i " r- rrl -< 00 ~t%:l "::0 :;~ -<~ g;~ :to~ ::!: ()~ 0 " -GJ). ;;;::< ~ ~80;;: _ 0. <:: "'"< L.....J IC <: .c1--1 _(II ~<z o ~ %G) O"m Q :to' >~ \1l < -to g-~:D c -r- CXl41 c)::;:> 8 "2 ~ m~ n :to " ~ ~ C-, rrl " '0 -, ro '" o " :to- c" ~. CD N CD N 0'_ ." .. .. +-' CD CD 0' 1-< 1M ,Z ~}~;?~w ,-, '.-( .:i;,~ " ~\~) ---',~",,~/ ( h;,,&\ '~";',~,~} ~"':2i~'~...."\0:":;-;":~~ '::SA: 'z";';Vi; "'f;~;~c7"';;;";;'I2~ '-4::> " .,~~-~ V'::!~~~', ~~ ~.t '. ':""', '.,~~~t - -" x~ '~.;;i;;' \'''':;':',:,_1 ,~\"... ''". ",' ":;;';";',:;,:0 ~~l~~ ',~' ~"~ - 0ft,,,', \.;''''':'::.:~V., '.:;1 ,.... j.; ~{"'. \"J/;.:f;.'(; . \'''''''' ~ II ~-.;j'i{;;"':~, ll\r. -:- :" '-P"-p J' ,~"' llltl \>::.c "1fitl",f1~. "1\>-, \. " " ,,<1 ., ,{', . ~ (,. -: d" ~ ":-::-',, . 4 . / "'- 'I. . '" ' ',),,~/..l;!A' ""./'I'''/i',~'c~ " "';~F~~~k1'~ I~~~~ft:l,~'" :-;. <'Yd.''>),''''" \."__'-!P"'I,~t1:S.'~,~iHP ~/'J,f'j:i---&;' , , \V, ~'." <J ~ "', .v~ ~o;:. r}iJ,' - I ~ '~fl. .JNif ~::-'~11.ti~~ ~~ I'" ."~~:~ ~'~t.~ /'-~'~~>----~$~~~t.-~'"~@'~/ --4~!---'(-~": /~~'.'- ~~ ~ '----- , 1-0 010 ~I;o :to 0:;0 0'-< o C ~ ). Z o ~ \ x':\ "'.; '~ , ':c\ '-;';'.':':) -) ,,\ )~.'{1'\ .-~0l/ ".,- / .~~.\ ':.,:::;:.\ ~'~?~~'.j . i ";"j ( ..-'\ p,,~~~ "'..:.-.:.~, "}';~/' \ ;~~~ ,~:~:~ , , The City of 7500 WEST 29TH AVENUE . WHEAT RIDGE, COLORADO 80215 GWheat <#Ridge September 13, 1996 Mr. Ward Mahanke,'P.E. TST, Inc. Of Denver 102 Inverness Terrace East, Suite 105 Englewood, Colorado 80112 Re: Sandalwood Manor, 3835 Harlan Street - Approval of Final Drainage Study, & Erosion Control Plan Dear Mr. Mahanke, This letter is to inform you that the final drainage study, and erosion control plan for the above referenced project have been reviewed and approved for construction. Please be aware of the following items regarding the construction of the project: 1. The proposed drainage facilities shall be constructed and approved by the City of Wheat Ridge prior to issuance of the any Temporary Certificate of Occupancies. 2. Erosion control for the project shall be placed in conformance with the approved drainage/erosion control plan and shall be maintained as needed during the course of construction. 3. All drainage improvements shall be constructed in conformance with the approved drainage report and plan. 4. It will be the responsibility of the contractor for the project to repair any damage to the existing public improvements on West 38th Avenue and/or Harlan Street as a result of related construction traffic in the area. Also, the contractor will be responsible for maintaining West 38th Avenue and Harlan Street on a regular basis such that they free of construction debris and tracking from construction traffic accessing the site. 5. Upon completion of the drainage improvements the engineer, TST, Inc of Denver shall provide to the City of Wheat Ridge a letter of certification stating that the various improvements, as defined in the drainage report and plan, have been accurately surveyed to confirm that their construction is in accordance with these documents. The certification letter shall be written and stamped by the engineer who prepared the (303) 234-5900 . ADMINISTRATION FAX: 234-5924 POLICE DEPARTMENT FAX: 235-2949 Mr. Ward Makanke, P.E. Adams-Avery, Ltd. Page 2 drainage report, and shall be submitted for review and approval by the City prior to issuance of the Temporary Certificate of ,Occupancy, or certificate of Occupancy. ve any questions, please contact me at 235-2868. s'ncere~ / / / -; ?~~ Greg Knudson Development Review Engineer GWK cc: Bob Goebel, Public Works Director Glen Gidley, Planning & Development Director John Oss, Sr. Project Engineer Steve Nguyen, Traffic Engineer John Eckert, Chief Building Inspector Meredith Reckert, Planner II John McGuire, City Surveyor Chuck Braden, ROW Technician William Lyons, Triton Development File MOUNTAIN STATES BANK 1635 EAST COLFAX AVE! DENVER, COLORADO 80218/388,3641 M8mbBf Fed/uBI Depos;t IflSUrlflC' Corporltiofl IRREVOCABLE LETTER OF CREDIT February 21,1996 City of Wheatridge 7500 W. 29th Avenue Wheatridge. CO 80215 i::!1 t.", tJI i.ji (J LJ't) G\t \S lfC) Attention: Susan Ellis Dear Ms, Ellis: We hereby establish our Irrevocable Letter of Credit No. SM-0296 in your favor, for the account of Sandalwood Manor, Inc, 3835 Harlan Street, Wheatridge. Colorado. in the aggregate amount of Fifty-six Thousand Two Hundred Fifty ($56,250.00) Dollars. This Letter of Credit expires at our bank at the close of business on August 31,1996, :;;.:.: Funds drawn under this Irrevocable Letter of Credit are available upon demand by presenting this Letter of Credit together with a signed, notarized statement by a duly authorized City official stating that improvements to the parking lot located at 3835 Harlan Street have not been completed as required by the City's rules and regulations. '.:.:: J'i "ll,n (.):.'1 r~ "- ~ All drafts must be marked "Drawn under Irrevocable Letter of Credit No, SM-0296, Sandalwood Manor, Inc., dated February 21,1996." Except so far as otherwise expressly stated, this Credit is subject to the Uniform Customs and Practice for Documentary Credits (1995 Revision), International Chamber of Commercial, Publication No. 500. &IY~ Dan E. Griffin Senior Vice President DEG/jv . DEPARTMeNT OF PLANNING AND DEV LOPMENT Building Permit Number: 3890 BUlLDINGIN$PECTlON: DIVISION. 2 5-2855 CI'1'Y OF WHEAT RIDGE Date: 9/20196 7~.ST29tH AVENUE WHE:ATRlDGE, CO 80215 F>toperty Owner: SANDALWOOD PAR NERSHlp Property Address: 3835 HARLAN ST Contractor License No.: 17884 Company: Adcon Signs - Advertis ng Concepts, Inc. Phone: 422-1533 Phone: 4478813 OWNERlCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify tl\lrtthe ~ distances pro~ by thi8 penn~ n are accurate, anc:l do not~~OJdlnancea' rules or regulal/Ons of the C of Wheat RIdge or covenants, .' or ~ of reconl; Ih!ll itll measurements hawn, anc:l allegallons malIe ... a~;tl\lrtlhllY8 ~. anc:l510 abldtl all condl , printed on this appUCallon, and tIiBt I _me lOll respons Io!" ance with I Wheal RIdge lellng Code (U.B.C.) enc:l an other IlP\)IIcabI8 Wheat IcIge . lor under this pee.:l:~. DATE f- ,.5-96 Tota!,: $8,604.00 $15.00 $0.00 $103.25 $118.25 Construction Value : Permit Fee: Plan Review Fee : UseTax: Description : 35 sa. FT SIGN SIC: Sq. Ft. : Approval: Occupancy : Walls: Roof: Stories : Residential Units : Electrical License No ; Company: Plumbing Licens No: Company: Mechanical License No : Company: Expiration Date : Approval: . Expiration Date: Approval: . Expiration Date: Approval: . (I) ThIs ~_JIilUedIn...........wIth UIa ~8Ions set Iof1h In r application and lasubied 10 UIa Iawa ofUla S1a1e ofC_ and 10 UIa Zoning ~ """e_ Code ofWheal_,COIotado 0< any other 0 bIe ordInonceo of the CIll<, (2) This JIOnnIl- eocpIreW {A)UIa _ ault1otlieOlll not co~ w n alxty (80) days from I..... _ 0< (B) tho building oulhol1zed II suspended 0< otlendOnecIlorapetiOcl~ofl20 ' . (3) H thI8 permit """"",,, a.- mey be acqulnld lor I fee of _ amount normoIly noqulled, orovIded no cIlIngeahlve -. or will be _in tho orlginai pIallo 8i1d . and any _sIon 0< abondonment not _ one (1) year, )f chongea '"" _ or J suopOnolon or abondonment __(I)_fUII_IIlaRbejloldlor._permlt (45) No _ of any "'"""'" _ be Qcoe _ will chonge UIa natural _ of Ier OIUslre.:=ve pn>blem. () ContoacIor-. IIOIIfy lhal/ulldlng InacecIOr tw8nly.foUr (24) ho...1n 8fIOI for IU a and IlhIU receive _ approval on lnapecUon cord bofor8 _ '~oftheJob. oflorW~'~~~" not be coliSlnlod 10 be 0 ponnItlor, nor on _I of, any_of the ~ ilding Inspector THIS PERMIT VALID ONLY WHEN SIGNED B THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HO RS PRIOR TO INSPECTION (8) SEP 19 ~96 10:21 P.2 OEPARTMEN"t <:IF COMMUNITY OEVELDPMENT BUILOING INSPECTION OlVlSION CITY OF WHEAT RIDGE, CDLO. TMtS 'ERMIT VALlO ONl.y 'tYt4l!:N $IGNED BY THt: CHIEF SUlLOING INSP(CTOJt At.IO RECEIPTED 8~L')W. !CATION FOR MISCELLANEOUS ff;RMI JO.ADD~8 OWNER ~~A'lf~ ""JIwu?/J CONTRACTOR AODRe.. "'1'-) (" ~.JIht) Jr. Iu_ ~J{)5(T ADDRE.. 'J...~q A1Qw~ ~N' PHONe ~~"l.-J~f3 ZIPcooe ~ CITY Pl;mUJt..!). m ZIPCOoe fiV~ CONTRACTPRIC". 6~,u() PHONE - LIceNSE NO. 1'~fJlJ OATE -.:-1'1-__ I, TyPE ~II .-,,0 P'oi....O or_ s~ 2_ MATERIAL ~t..Vm: +o1'rGR.J"l...1 c. ToIeI S4uer. F.., SJGNS !.ILLUIlUUlTIOH v..E] NoD T".FLt.~ !~I.lIwr'fIIo. " SET UCKJ'ROMflftOHRTYLINf: H- ~ E~ w_ lofttC- ~"'-'.or ( """'.f..." 0 0 0 ~ Soli,(J Mor. ThDn 80% o....a LH6 na.. 10% 0,.,. - H-S_E___w_ ZIll'lt_~I_lfItfMtor DODD _ PERMIT NO, FENCES l Tv!i'E ~ MATERIAl ,. SiT IAtK AltOM PItOP!RTY lINE (Specif ""jell......'1 I. OTHER · a DRM SK!.TCM OIl: $MOW .LDW. THf fENCE,SIGN,QA OTHE" STltUelUtr:,GMNG DlSTANtU FRClM JlR(llEItTY lIC$. MTIIOcS OR PItO.JECTIONS INCLl<<J)) .... ~ S:~ SIW fJ<#"I'J r ~ ... ... > > ~ ; -J}!1 ~ mG1~ . ~ -~ f SA ttG rUlSurP >> tt' /,.J . STREET NAME. SHOW I:ISTANCU fJlQM TIC MAIN 1UJL.Dh; TC>AO..IOWlNG HCIUSU. STREETS,AHtl PRONJtT'f UtC$;OH tMlCU.M LmS, 8HOWLUII OISToUICf TO PRQPfRTY LIHES, NOT .....x...... OR AYlRAGE CfSTAM:E. _ L ~ APPLICATION FOR PLUMBING; ELECTRICAL; MeCHANICAL PERMIT TH1SAPPLlCATlON WILL BECOME A PERMITTO PERFORM THE IHOICATfO WOf!.K OJlLY UPOH '1AlIDATIOH BY THE BlJILOlfilI& INSPECTION OIV1SIQN. PERMIT Will EXPIRE 180 DAYS ~ROM lHf CATE OF ISSUMCE IFWOftK !SHOT STARTEO WlnilN THAT TIME. ELECTRICAL PERMtT PlMeNG ""AMIT MEt>lANICAL Pf:IlMlT STAft utENSE NQ STATE lICENSE~ , RE LlMlfIIl SIll! . ILLEGAl FLQ()1t . 1ST Z.. ..., 4TH NO. .... NO. WAT!R aDS(T -... - OTU TEMPORARY W!TCR --. HOT_ - lTU Nf.W $tRlllCE 'WPS Lt.TM Tue TU" - OTU CHANGE SE;A\l1Cf -AMPS ....... :~"T"* -OTU L""'ING .... HEATING ....... ..... TOo ~" SU6.CIRCUlTS _nil IEAnR 1J11l.1T't fRAHGE:. DISPOSE". tfC) AUTO.MSHE:R "XT S 00SH _. --........... WlRtNG hK)'W'$ . CQNTROL.$ F1..l:lOR OflA1N I!U\ll1'OII SIGNS ........ nt~'IIR -- K_ AIXlITIOtf TO OLO WORK on... MOTORS OVER I HP TOTAL FIlCTUIItfS -- PERMIT FEE hOT,,-,1O -..us ~ I ......w ockllowl,uQ41 f"gl lit;, OIi'ilIlico. 'iall .1 COI'OCI ellll ""do"I..." flier I USE TAX C.IIIIM 1'0" '"i, lI'oj,el "nlillllil allDlj. cotion i, OP"oY,eII. , 111.011 COIII,I)' _illl TOTAL FEE $ ,,,. 10,,",' 0' 'M Slgl. 01 Colo,ade ""4 10 'ho ZOftillQ IlftoulatiOn, GlleII B..ilclinV APPR(NEa co.. 01 ,It. Cit, or WIlUI Rid... A~r alSAPPROVED .,iolo';OIl of 111. obo", '.''''' will COli" CHIEF BlJILOlNG INSPECTOR,Cityo! _t RIdeo i-.diCilt, '."oeotion of Illi, p.,...., 2z~~ 0011 Issued .. SEP 20 '9606;10 .~. 13) ~ ll.. :.--' ~ i;JY" ,.'" \\' P. ~;..',. \..... .... .~.:.. .... . ASPHALT <( '. .ct) .:..'; 6 .... ~.. r.;:..: .... , .- .~ . ........ '''" . CD It: :> y :;3 <( 01 ASPHAL T .. '" N o r.:....iol- ~;) :0 / 11 SPACES $ 3 24' 19' 19' 24' .. " N tV ~'f It: a II: ... <.> "W -' 5 .:. .~. " ;:;:':~ ',' : '."" ~ . " .... <'.-;;- 13 SPACES 14.13 - tJ ot 1'::; 'r . co 4' R. .Qo 6 SPACES 6 OU"TFA CUR ti - <: c- -~- 24' I 'A / r- r-.. ..,... SEP 20 '96 06: 11 n:~ ~ ~~ ~s: ~ ~Q ~ "", ~~ E 1tIta ~ Ou ~m l II~ =' ~i l~ ;II'l 0 ~ -il: i tI~ i ~)oo IQ ;;: ~i ~ U n i ~~ 8 s~ ~ ~ ~ ~ ~I'l ~ ~ " g ~o ~ i!i ~ ill ~~ "Jl a ~ <; I ~ .. ~ m ~ g ~ ~ Q i ~ i P.3 i: w ~ , 1; 9 ~ Ii ~ 0) II ~, ~~ @8. o o i'i .. ~ Ii o I ~ in, ~ i 'II mllil::lwt; liIIl!!!! jl~. ,. ~ 1~ .I,! .p ia I ~.glld Building Permit Number : Date: NERSHIP PhOJ'le : Phone: 4169734 ConslrucllojlVllIuEl : PEl~Fee : Plan Rev(ewFee: U",Tax : Total : GN AND FUTURE COURT LIGHTS SIC: Sq. Ft : Roof: Storles : R~ Units: i' Plumbing L ' 'No : Company : MechanIc:IlH.IcenSe No : Company ': Expiratlon,Oale : Approval :, . $2,200~OO $57:00 SO.OO $26.40 . $83.40 DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: Contractor License No, : .:56..:3~? .J-I<A.a.k..-,) :;;;1""\, 2.~~'1 -:51, Company: A ~ YvL '2::.1.ec..-~l2-fL- ~'--- Phone: Phone : 9~-' Lj.Ib-9-'f3 Lf OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value ~/.;zc:o, ee Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (V. B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED f\ ' _ - o..{; ~ _r>-'\J rlA TE 9~~~ I - Description: ~II."-<J? i..J;..Ide.'5-"-i4:-V-Cr Q,.-..Ic!..;;\'- 4'- Le.hI2':~"u<7 I^-'z:-- . Total: -{i;,J1.- ,A :5> f;;;.J -t BUILDING DEPARTMENT USE ONLY Z~jj.llf~ommji~ Approval: Zoning: fi!.!!iRlji:Jlf&omnfeiitS::!l Approval: palilii;l~.;;pJ.1lI1l~nts}j Approval: Occupancy: Walls: SIC: Sq, Ft : Roof: Stories: Residential Units: Electrical License No : Company: .A.4' M- e~\L- =zu:-, Plumbing license No : Company: Mechanical license No : Company: Expiration Date: Approval: ~ ~Ia~~l.~ Expiration Date: Approval: . lle!alfB1~~!rn!t!'dBII Expiration Date: Approval: _ ""r.-"-""R",.nlo'''''- _ .....,i!.,,,,.,_.,,""'.""'-""""'"' (4) (5) (6) This permit was issued in accordance with the proVisions set forth in yapur application and is subject to the laws of the Slate of Colorado and to the Zoning Re,9ulatlons and BUilding Code of VVheat RJdge. Colorado or any other applicable ordinances of_ the City. ThIs permit shall expire If (A) the war!< authonzed is not commenced wlthm SIXty (60) days from Issue date or (B) the building authorized is suspended or abandoned for a ,period of 120 days. If thiS permit expIres, a new permit may be acquired for a fee of one.half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the Job The Issuance of a permit or the appro,val of drawings and specifi.cations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the buildmg codes or any other ordmance, law, rule or regulatIon. (1) (2) (3) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION 'l!~t,.,",""."".,.,. "''''W:''d~'''''"'~:'''''":'"''1''''''''7''"'' ""~,,,~,,,,,,?!,,,~.,,,,.A},,! ll,J(I~,"'",'''''i",.,":","4;;.JL" "",~"":~U:"",."4~~,~,,.tl!~.,,, i'~~'!"":"'f"''''' ,> DEPARTMI$NTOFPlANNING AND DEVELOPMENT Building Permit Number: 3729 (. " ;,' BUlLDlNGINSPECTIOfll DIVISION - 2~5-2855 cm OF ~TRIOGE Date: 8121/96 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: SANDALWOOD PARTt-lERSHIP Property Address: 3835 HARLAN ST Contractor Ucense No.: 18841 Company: Lobar, Inc. Phone: Phone: 4939085 OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING j6.ND AGREEMENT Constructlon Value: Pennit Fee : Plan Review Fee : UseTax: $139,485.00 $1,095.00 $0.00 $1,673.82 , $2,768.82 (OWNERXCONTRACTOR) SIGNE Description: Total: STEM, GRADING AND ASPHALT IMPROvEMENTS BUILDING DEPARTMENT USE ONLY SIC: Sq. Fl : Approval : Oceupancy : Walls: Roof: Stories: Residential Units : Plumbing Licen~ No : Company: Mechanical License No : Company: Electrical License No : Company: Expiration Date : Approval : . Expiration Dale: Approval: . expiration Dale: Approval: . (1) ~.~~;::;:;=~~coJ:,e:::~~:.~=::t'h~1llo_.f1j,,'~oICo1oradoondto"'ZAlIlinQ (2) ~W1OII""" (1.18_auIhoriZedlollOl..o.""...__ lbdy(8O)lloys"""'-, d8llor(8)1I1ObuIIdIng_lo..--or _lOdforOporlOdolla20 I. ' (3) .1hI$11O"l'iI~o"""" may be""lulred foro fOoof_tho omount normoIIy"",*""."- no __ hoNo _ orwllllo_1n1l1O OIjgInoIpIonIoiIdll'O'r T ondony__oro_,",II\Ol_ono(l)_. If__--or.~or_.....,..,1 _ono(ll_.tllII__llojJoldforo__ , l4) ""_oIl\1l\1.......W1OII bitdOnoltlol wIIChOngO lho _ - ofWotorCOUllng 0 __ ~ 5) Qon1nIl:Il>rIl1ioll ::"',8uIIcIIIlG 1nI.-r1loonly.!out (24) houri In od\lonco for 0lI1ntpoc:11On1 oncIlhOH -.. _ __ on HOBpOO1IOIl cord_ (8) 'l::'==- """"",...W:=tt".r'dtOwinga ond spoclIiCotlol1ls""ll IIOIboconatnJOd to be 0 pormItfor. _ on --'of. ony _ 011110"- of1l1Ob or _ ,ndoorntgulotlon., Chief ding Inspector THI PERMIT VAUD QNL Y WHEN SIGNED BY THE CHIEF BUILDING IIIlSPECTOR AND 1M YOR CALL: 234-5933 24 HO\ilRS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 3~d /-'1d:> 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner::EDl3 (,Jf/.-,t::;D/tJ _ ~ sA.- propertyAddress~~)fr.*l1.~ 3J'~::> Phone: Contractor License No. : ~if1- Company: /-..08/1 JR I ;:,tJJC. Phone 97Lr79~- 5bJ"~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: 1/3'7/'105- Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that [ assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. DATE Total: (OWNER)(CONTRACTOR) SIGNED Description : @~ \ ~I ~~~ BUILDING DEPARTMENT USE ONLY ZoninlfCiimmlints:] Approval: Zoning: ~uir(ling~Col!1ments:' Approval: Public:Wo-rkS"COmmenls:l Approval: SIC: Sq. Ft.: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: :EI ~PIans'Requir.e::~ Expiration Date: Approval: ~ 1P'lan~R8CfI1!~.m Expiration Date: Approval: ~ "!lPfanlf~eqUifell~ (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Re,gulations and Building Code of Wheat Ridge. Colorado or any other applicable ordinances Of_the City. ThiS perrmt shall expire If (A) the work authanzed IS not commenced within SIXty (50) days from Issue date or (B) the building authorized is suspenced ar abandoned for a periOd ot 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally reQuired, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or a:andonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor Shan notIfy the Building Inspector flNenty-four (24) hours in advance for al1lOspecllons and shall receive written approval on inspection card before proceediing with successive phases of the jab, The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit tor, nor an approval of, any violation of the provisions of the building codes or any other ordinance. law, rule or regulation. (1) (2) (3) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION