Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3223 Fenton Street
i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION N TICE ( Q 1�;: r;F-M_A,_ Inspection Type: a lam ` Job Address: c Permit Number: '2_02CD C> ( ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes N When corrections have been made, scule for r -'section online at: http://www.ci.wheatridge.co.uslinspec ion C City of Wheat Ridge Residential Solar PERMIT - 202001355 PERMIT NO: 202001355 ISSUED: 07/27/2020 JOB ADDRESS: 3223 Fenton St EXPIRES: 07/27/2021 JOB DESCRIPTION: Install solar PV system, 3.2 kw, 10 panels on house; structural required *** CONTACTS *** OWNER (317)514-6160 MERCHANT LINDSAY SUB (385)482-0045 LEE HATLEY 180271 BRS FIELD OPS, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,992.74 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t[ie legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the original permrt fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Budding Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or gran ' of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or y dinpnce or r lation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Solar PV Installation Date: Monday, July 20, 2020 3:18:40 PM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 3223 Fenton Street Wheat Ridge, Colorado 80212 Property Owner Name Lindsay Merchant Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 317-514-6160 Ipushies@gmail.com Lindsay Merchant payment form.Ddf CONTRACTOR INFORMATION Contractor Business BRS FIELD OPS LLC Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the 180271 City of Wheat Ridge) Contractor Phone 385-482-0045 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email permitting.department@blueravensolar.com Address Retype Contractor permitting.department@blueravensolar.com Email Address DESCRIPTION OF WORK Scope of Work Roof Mounted Solar Array KW 3.2 # of Panels 10 Location of Panels House Roof Structural required Yes Upload engineer letter Merchant Residence Wheat Ridge CO Stamped flat.pdf or pages on 8 1/2" x 11" only Solar Installation Plan Permit Pack 9105 Lindsay Merchant Stamped flat.pdf Set on 11'x17" only. Project Value (contract $8,992.74 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for shandria Hall Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. Dow -us Domus Structural Engineering, LLC P.O. Box 6986 1` Broomfield, CO 80021 N G I N1� E R J 14 G T: L C; 530-864-7055 Domusstructural@gmail.com July 15, 2020 To: Blue Raven Solar 1403 North Research Way, Building J Orem, UT. 84097 Subject: Certification Letter Merchant Residence 3223 Fenton Street Wheat Ridge, CO. 80212 To Whom It May Concern, Ajobsite observation of the condition of the existing framing system was performed by an audit team of Blue Raven Solar as a request from Domus Structural Engineering. All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project, the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof. The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements. The observed roof framing is described below. If field conditions differ, contractor to notify engineer prior to starting construction. The roof structure of (MPI) consists of composition shingle on roof plywood that is supported by 2x6 rafters @ 24"o.c. with ceiling joists acting as rafter ties. The rafters have a max projected horizontal span of 9'-0", with a slope of 18 degrees. The rafters are connected at the ridge to a ridge board and are supported at the eave by a load bearing wall. The existing roof framing system of (MPI) is judged to be inadequate to withstand the loading imposed by the installation of the solar panels. Structural reinforcement is required. Purlin upgrade is required on (MPI) on all roof sections that directly support solar PV. Install new 2x6 purlin member to existing purlin with 10d nails at 6" o.c. along the length of the purlin. The spacing of the solar standoffs should be kept at 72" o.c. for landscape and 48" o.c. for portrait orientation, with a staggered pattern to ensure proper distribution of loads. The scope of this report is strictly limited to an evaluation of the fastener attachment, underlying framing and supporting structure only. The attachment's to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading. All panels, racking and hardware shall be installed per manufacturer specifications and within specified design limitations. All waterproofing shall be provided by the manufacturer. Domus Structural Engineering assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Note: Seismic check is not required since Ss<.4g and Seismic Design Category (SDC) < B OQ,N9 Ltd � M AT�� ., Design Criteria: V� � , • Applicable Codes = 2012 IBC/IRC, ASCE 7-10 ; �r • Roof Dead Load = 8 psf (MPI) ; 0 5 10 • Roof Live Load = 20 psf • Wind Speed = 135 mph (Vult), Exposure C, Risk Category II • Roof Snow Load = 30 psf ••...... G\ • Attachments: 1- 5/16" dia. lag screw with 2.5 inch min embedment �ONM- depth, at spacing shown above. Digitally — Ryan M.1 Please contact me with any further questions or concerns regarding this project. Atwell Dat e:202i -06'00' Sincerely, Ryan Atwell, P.E. Project Engineer Merchant Residence, Wheat Ric g� i*�+0 M CI S a15Rod Reforms Structural Engineering, LLC P O. Box 6986 L& design on PV System (Per Clue Ragan Solar) 30 pA Broomfield CO 80021 T R U C T U R A L Y Standoff Spacing= 550X 90.861]055 N C I N C& k d N C., LL G 6616 Romussructual@g me it com of loading Grrviry Loading pef=Ground Show read- .Popo p=OC,GIpm (ACCP -E]-1) C, - Exposure Factor= 1 (ACCP -racers) G=Thermal Factor= 1 (ACCP-Table73) =1mpoRanreFactor= 1 p=FM Amo Snow read- too 0Rod Ps CA (ACCP -E]-2) Cs=Slope Factor= 1 A Supped Wad Auv Wady 3FO ad Rad Wad =l pop (Par Blue Baden Solar) B L Adiucted to l w Agree Slope a15Rod ad System NRight 400 design on PV System (Per Clue Ragan Solar) 30 pA X Standoff Spacing= 400X Y Standoff Spacing= 550X 6hntlm deputy P%a- 2200A Point Wads N Startltlls 6616 None: PV slandons arestaggered to ensure proper distnMlon of loading Bmf ua Wad -2B tsl None Ad lies load 6 removed in areas covered by PV army Wad Bead Wad lair) Composition Shingle 400 PoN byword 200 end Farmers ®24'oc 115 Vau6ed Ceiling 000 (Ceiling NA Vau6ed) Miscellaneous 01 itlal Wad DL dead) 80(51 BL Adimied to l w Agree Slope w4Rod Merchant Residence, Wheat Ridge, CO. Sent g� oomus Structural Engineering, LLC i*�+EDD M CI S P 0 Boz 6986 4} T R U C T U R A L Broomfield CO 80021 5308647055 N 9 I N R R R I N C, F, 119 Oomusstructual@gmad cam Wind calculation_ Per ASCE 710 Components and Cladding mind speed a>map Exposure category C POABhape Hp/Oabo Poolelope 18degreea Wan Pool lkigbt 20 ft Etopiw Wnd Prea 193N Design Wind Prtee no Lap Wind Pressure P v hM6'Ln do— 696256• NY Sat M a Vi' IEg303-11 K, Exposure coefficient) =69 (Table 3O3-1) Ka topographic fauna= 1 (To 2681) ad Mind Vire.cronaldy Factor) =695 (Table 26611) V(Desgn Wmtl Speed) -135 mph (To 2651A1 Risk category =ll (Table 1d11 do— 3599 0Rado-2142 Standoff OplM Calculations Porti Zone1 Zone2 Zonef PoaNw ccp= L94 —139 —223 636 (To 36111 lblmRescue = —1795ago —29nago 47 71 134 red X Ramon Spring= 466 496 291 YSSandoff Spring= 556 215 215 in9ufaryRaa= 2296 1166 133 hoping grind= PS Ie 327 ie anile 30ndnx grind Cakulatlnnslandrape Zona 1 Zona 2 Zona FnNlw ccp= L94 —139 —223 636 (To 3041) lblfaRescue =—1795ago —29IIago -01I1per 100red (Minimum) %Randoff Spring= 696 696 466 YSSandoff Spring= 356 175 175 Tric — 2196 1656 166 hoping grind= 3711e 3o ib 334 111 M" aaM- Saudi Uplift capacity 450m ash m remdn3s5 to demand memea,off Founder6aparTy— Fastener— iadener— iiia aga9 CqM Nurfteroi 1 Embadmam Depth =25 a fund Capacity Per Inch =256m poly Fj Fj Paden, Capacity— WSm 4a^ff6 4 F8off 58 DOE of 19=661m 6672m capacity>395 to demand mnetnn,OK Merchant Residence Meat Ridge, CO. dsm3 g� Romps Structural Engineering, LLC i*�+0 M CI 5 P O. Box 6986 L& T R U C T U R A L Broomfield CO 80021 90.861]055 NG T N E E R J NCc RLC DomusAructual(@g me it cam Framing Check _ (MP1) PASS w=83Ptl Dead Wad BA pa PVlmd a2Pan Show Load PoOPan 25Rallers924"0C Governing Lind Combo -DriSL Member8pan=9-0" Se ictal Wad 416 red Member ROFedies Member Size Bin i) Iini LumberSp/Cr Member Spacing end 766 201 DR2 ®24"ac Mock pending 9re99 Po(pN)= Vb A Cd A a A Cr (NDB Table 431) 900 A 115 z 13 z 115 Allowed Bending Stress =1547 a psi Maximum Moment=rWL°2)/8 AT za2 XA =1010056 in# Actual Bending Stres=(M&amum MomerA)/ 8 la35 t1 Nice da AMBA-864%9ressed-ihrelue,e1K Fllm'reda Actin-252%Suressed - ihrelue, 0 Merchant Residence, Wheat Ridge, CO. Sam ChCKJMQM'J� Allowed Wlleplon (Total Watl)= (E= 1@g000 pA Per NDB) (CANAin Actual Otor Basedon= Cort Span Def Actual Deflector (Total lmtl) _ (OUp)10 WF 1) 01541n 0154 in - =NO2 > VI80 IDaelOre Be MY Allowed Second (more Load) = Li 045in a Actual DeflectorDeflector(uve w= Upad) 086•e1) 0111 In urs > u240 maemreBe Cock %ear Member Area =831ni Fvpsi) =1Npsi (NDB Table 4A) MoundShear -Fv A=148616 Max Shear (V)=w'L12= W416 Fllm'reda Actin-252%Suressed - ihrelue, 0 Merchant Residence, Wheat Ridge, CO. Sam (E) FLAT PURLIN (E) (E) DIAGONAL STRUT AND PURLIN (E) CEILING JOIST (N) 2x6 PURLIN SISTER. ATTACH TO (E) PURLIN WITH 10D NAILS AT 6" O.C. (E) INTERIOR LOAD BEARING WALL PURLIN SUPPORT UPGRADE - ELEV. Domus Structural Engineering, L 1210 Birch Street Broomfield, CO 80020 (303) 466- 3014 Domusstructural@gmail.com (E) COLLARTIE (N) 2X4 CLEAT ATTACHED TO (E) STRUT WITH 16D NAILS AT 3" O.C. ALONG LENGTH EXTEND TO WITHIN 3" OF THE CEILING. Date: 9/1/18 W1 GENERAL NOTES CODES AND STANDARDS 1. ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE (NEC), 2015 INTERNATIONAL BUILDING CODE (IBC), 2015 INTERNATIONAL RESIDENTIAL CODE (IRC), 2015 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES. 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. SITE NOTES / OSHA REGULATION 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. 5. NO. OF SHINGLE LAYER: 1 SOLAR CONTRACTOR 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM. 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT AVAILABLE. 9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, DC COMBINERS, DC -TO -DC CONVERTERS, SOURCE CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (B). 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. 11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. EQUIPMENT LOCATIONS 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]. 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY [NEC 690.31 (A) -(B)] AND [NEC TABLE 310.15 (B)]. 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT TO THE UTILITY AC DISCONNECT, OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. City of 'I+ Wheat idge COMMUNITY UEVELC I MENT APPROVED Reviewq for Cade Compliance iii. �.i./iia��.�i�� _ 72�:2_02_0 Plans Examiner Date VaIWIW of permit: The issuance of a permit or approwt of pkns 5W4koMm and compumbons shag not be a permit far, or art approval of, any vrorabon to any of the provisions of the budding code or of a(V City ardomwes. Permits presuming to givr authority to vialao or carrel the pro"gans of the fLoft codes or other ordnown of the City shah root be wU ACDIAI \/IC\A/ DESIGN CRITERIA WIND SPEED- 135 MPH GROUND SNOW LOAD- 30 PSF WIND EXPOSURE FACTOR: C SEISMIC DESIGN CATEGORY- B SCOPE OF WORK z1% r�t 6 1 dw d r dA We :■ SITE SPECIFICATIONS OCCUPANCY -R3 CONSTRUCTION - V -B ZONING- RESIDENTIAL A INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM 3.2 kW DC PHOTOVOLTAIC SOLAR ARRAY ROOF TYPE- Comp Shingle MODULES- (10) Trina 320 INVERTER(S)- Enphase IQ7 Microinverters----- RACKING- Unirac SFM Infinity Approval Notes: 1) PN array system to have grounding system installed per Part III of Article 250 per 2017 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2017 NEC Article 250.53(A)(3). 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(6) SHEET INDEX 7 � 7 PV1 - COVER SHEET PV2 - PROPERTY PLAN PV3 - SITE PLAN PV4 - EQUIPMENT & ATTACHMENT DETAIL PV5 - ELECTRICAL SINGLE LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS & ELECTRICAL NOTES PV7 - MAIN BREAKER DERATE CALCS. (IF NEEDED) PV8 - LABELS & LOCATIONS PV9 - CUSTOM DIRECTORY PLACARD (IF NEEDED - NEC 690.56(B)) i Noe - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf FNABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 i C.) f� 7 � 7 PV1 - COVER SHEET PV2 - PROPERTY PLAN PV3 - SITE PLAN PV4 - EQUIPMENT & ATTACHMENT DETAIL PV5 - ELECTRICAL SINGLE LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS & ELECTRICAL NOTES PV7 - MAIN BREAKER DERATE CALCS. (IF NEEDED) PV8 - LABELS & LOCATIONS PV9 - CUSTOM DIRECTORY PLACARD (IF NEEDED - NEC 690.56(B)) i Noe - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf FNABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME COVER SHEET PAGE NUMBER REVISION PV1 I 0 C.) N Q O 0 O N M Z C p i--' 0 N Q U U U U) a) O C: Z U) ca LL W 70 CU U) N C: U) J M > 0 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME COVER SHEET PAGE NUMBER REVISION PV1 I 0 a� U) C O A.- N LL M N N M I C:f_%C:nin INV INVERTER & DC DISCONNECT [;UB] (E) SUBPANEL Fc] (N) LOAD CENTER E AC DISCONNECT F—ml UTILITY METER MSP MAIN SERVICE PANEL JB JUNCTION BOX El TRANSFER SWITCH C❑ COMBINER BOX/AGGREGATOR S PV REVENUE METER ® FIRE SETBACK EMT CONDUIT RUN (TO BE DETERMINED IN FIELD) PV WIRE STRING PROPERTY LINE SCALE: 1/16" = T-0" 0' 4' 8' 16' 32' Nw BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf FNABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME PROPERTY PLAN PAGE NUMBER REVISION PV2 0 C.) N r) C) 0 O N M Z C O 0 N Q U (n (n i _i± 70 LLI LL Z07 ca LLCU W (n 70 N (n J M > 0 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME PROPERTY PLAN PAGE NUMBER REVISION PV2 0 MP1 # OF MODULE AZIMUTH -270 PITCH -180 TSRF:78% AREA: 736.01 OVERHEAD SERVICE LINE I Fr,Fnln NINV INVERTER & DC DISCONNECT C.) Q [;UB] (E) SUBPANEL N LC (N) LOAD CENTER AC AC DISCONNECT El UTILITY METER N M MSP MAIN SERVICE PANEL -1--i0 E JUNCTION BOX TS TRANSFER SWITCH r COMBINER BOX/AGGREGATOR w PV PV REVENUE METER O ® FIRE SETBACK — LU CU CU -0 EMT CONDUIT RUN LL U) (TO BE DETERMINED IN FIELD) O s 0 5 10 z I PV WIRE STRING O i j PROPERTY LINE Nw- BLUE RAV 1403 N RESEARCH WAY, BUILDING J OREM. UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 SCALE: 1/8" = 1'-0" CONTRACTOR: 2' 4' 8. 16' BRS FIELD OPS 385.498.6700 PURLIN UPGRADES REQUIRED ON MP1. REFER TO STRUCTURAL DETAIL Ryan M. AND CALCULATIONS PACKET FOR Atwell ADDITONAL INFORMATION. Digitally signed by R,PROJECT NUMBER M. Atwell Date: 2020.07.15 76829518 11:27:27 -06'00' /0'Azoor N SHEET NAME �aZa SITE PLAN PAGE NUMBER REVISION PV3 0 N T_ C.) Q Sealed For Existing Roof N CHIMNEY & Attachment Only °O Z O C N M O Q -1--i0 N U -r- (n (n O U C N LU ND0 Ll p�•......•. Fri ': • uL C o � L U)Z Off M. gT'•.cS�. — LU CU CU -0 � (� U) N co s 0 5 10 J �p DRAWING BY DIN ENGINEERING •� /OWL "� DATE July 15, 2020 PURLIN UPGRADES REQUIRED ON MP1. REFER TO STRUCTURAL DETAIL Ryan M. AND CALCULATIONS PACKET FOR Atwell ADDITONAL INFORMATION. Digitally signed by R,PROJECT NUMBER M. Atwell Date: 2020.07.15 76829518 11:27:27 -06'00' /0'Azoor N SHEET NAME �aZa SITE PLAN PAGE NUMBER REVISION PV3 0 PV ARRAY INFORMATION LL LL O r) Z U) O O II H c� Oa) m U J_ U) Q H W 0 LL LL 0 Q U) oCD LU II J co � U J U) U PV MODULE COUNT: 10 MODULES # OF ATTACHMENT POINTS: 20 ARRAY AREA: Module Count x 17.51ft2 = 175.1ft2 ROOF AREA: 2059.0ft2 % OF ARRAY/ROOF: 8.5% ARRAY WEIGHT: Module Count x 50lbs = 500.Olbs DISTRIBUTED LOAD: Array Weight _ Array Area = 2.86 Ibs/ft2 POINT LOAD: Array Weight _ Attachments = 25.Olbs/attachment Infinity IMRAIL Trina 320 PV MODULE (E) ROOF MEMBRANE UNIRAC SLIDERS AND TRIMRAIL ROOF ATTACHMENTS FLASHING PV MODULE (BEHIND TRIM RAIL) MAX, 48" MAX. - Unirac SFM Infinity TRIM RAIL PORTRAIT RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER. G PV4 �� '_.� SFM Infinity Switchblade Flashkit Unirac SFM Infinity FRAME LANDSCAPE ARRAY DETAIL, FRONT VIEW Scale: 3/8" = 1'-0" PORTRAIT LANDSCAPE ZAY DETAIL, SIDE VIEW 5/16" STAINLESS STEEL LAG BOLT ROOF TYPE: Comp Shingle WITH 2-1/2" MIN. EMBEDMENT ROOF FRAMING TYPE: Rafter AND FLAT WASHER (E) BUILDING RAFTER OR TOP CHORD(TRUSS) 2x6 @ 24"O.C. STRUCTURE CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x6 @ 16"O.C. Unirac SFM Infinity Trina 320 PV MODULE (E) ROOF MEMBRANE UNIRAC SLIDERS FLASHING PURLIN UPGRADES REQUIRED ON 5/16" STAINLESS STEEL LAG BOLT MP1. REFER TO STRUCTURAL DETAIL WITH 2-1/2" MIN. EMBEDMENT AND CALCULATIONS PACKET FOR AND FLAT WASHER (E) BUILDING ADDITONAL INFORMATION. STRUCTURE Scale: 3/8" = T-0" Sealed For Existing Roof & Attachment Only Ryan M. Digitally signed by Ryan M. Atwell Atwell Date: 2020.07.1 11:27:17 -06'00' Nor - BLUE RA 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME EQUIP. DETAIL PAGE NUMBER REVISION PV4 0 C.) N Q C) 0 O N M z C O 0 N Q U 07 07 iC: N 70 LL1 LL z cn LL W CQ CU 07 70 N (n J M > 0 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME EQUIP. DETAIL PAGE NUMBER REVISION PV4 0 PURLIN UPGRADES REQUIRED ON MP1. REFER TO STRUCTURAL DETAIL AND CALCULATIONS PACKET FOR ADDITONAL INFORMATION. 1'L'I ; LAT PUFF (E) RAFTERS Sealed For Existing Roof & Attachment Only (E) DIAGONAL ETRU' ,�,PDO LI�F�s AND PURLII c�,•00 M. ATGy ,FO 0 <. 0 5 10 CONAL EN Ryan Digitally signed by Ryan (E) EILIN R a n M. M. Atwell JOI E Date: 2020.07.15 Atwell 11:27:03 -06'00' W1 11-1 I Lk*1'1w BEARING WALL PURLIN SUPPORT UPGRADE - ELEV. Ne - BLUE RA 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney COLLAR TI E # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 4 CLEAT ATTACHED TO (E) 'RUTWITH 16D NAILS AT 7- U Q . ALON LE N GTH E TE N D o WITHIN 3" OF THE CID o N TILING, z _0 CU C6 O Q 0 N U U U U) O z a) U) W > 70 N _r (n C:_ U) J co DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER city of 76829518 Q / / ajaASHEET NAME 7 L�ZaZa EQUIP. DETAIL PAGE NUMBER REVISION PV4 0 (1) 10 AWG THHN/THWN-2, CU., BLACK (Ll) 10.0 A AC (1) 12 - 2 OF -B W/G, THHN/THWN-2, SOLI DCU. MAX 10.0 A A( 15 (1) 10 AWG THHN/THWN-2, CU., RED (L2) 240 V AC 3 240 V A( J (1) 10 AWGTHHN/THWN-2, CU., WHITE (N) (1) 10 AWGTHHN/THWN-2, CU., GREEN (EGC) (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT EXTERIOR 1. ALL CONDUIT TO BE RAN AT LEAST 7/8" ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. 2. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. 3. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. PV SYSTEM DISCONNECT - BREAKER TO BE INSTALLED WITH CIRCUIT LOCKOUT, SO AS TO BE LOCKABLE AND VISIBLY OPEN OR CLOSED (NEC 690.13 & NEC 705.22) (E)200A MAIN SERVICE PANEL (E)150A / 2P MAIN BREAKER (E) GROUNDING ELECTRODE (S) PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER VERIFICATION WILL BE DONE TO ENSURE THE GROUNDING ELECTRODE SYSTEM IS CONGRUENT WITH CURRENT REQUIREMENTS [NEC 250 PART III.] IF NOT, A NEW GROUND ROD WILL BE INSTALLED. (N) g' COPPER GROUND ROD, 8 FT LONG, AT LEAST 6' APART FROM (E) GROUND ROD. GEC INSTALLED PER NEC 250.64: 4 AWG SOLID COPPER "OR* 6 AWG SOLID COPPER GEC PROTECTED BY RMC/PVC/EMT INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12]. (1) 12 - 2 OF -B (or NM) W/G, THHN/THWN-2, SC MAX 10.0 A 2 OR 12-2 TC-ER,THHN/THWN-2, CU., 90C 240 V Enphase IQ Combiner 3 X -I Q -AM 1-240-3 (SOLAR LOADS ONLY) N (N)2 G kL:� I NTERIO "JUNCTION BOX(S) FOR WIRE SPLICING ONLY - OPTIONAL IF Q -CABLE (TC -ER) OR OF -B USED FOR ENTIRE HOMERUN JUNCTION BOX JUNCTION BOX FL, n L, �(1) 12-2TC-ER,THHN/THWN-2,CU. MAX 10.0AAC 1 (1) 6 AWG BARE, CU (EGC) 240 V AC Approval Notes: 1) P/V array system to have grounding system installed per Part III of Article 250 per 2017 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2017 NEC Article 250.53(A)(3). 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(6) EXTERIOR (10) Trina 320 UL 1703 COMPLIANT (10) Enphase IQ7 Microinverters MICRO INVERTERS UL 1741 COMPLIANT 10 MODULES MAX FOR ALL SUB -BRANCH CIRCUITS) TO COMPLY WITH VRIS CALCS (1) CIRCUIT OF 10 MODULES C" of 0 '4%W BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 (E)150A / 2P C.) (E)LOADS N (N)20A/2P L' L: NF N e r) 120/240 VAC 60HZ O 1 PHASE TO UTILITY J GRID O G (E) GROUNDING ELECTRODE (S) PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER VERIFICATION WILL BE DONE TO ENSURE THE GROUNDING ELECTRODE SYSTEM IS CONGRUENT WITH CURRENT REQUIREMENTS [NEC 250 PART III.] IF NOT, A NEW GROUND ROD WILL BE INSTALLED. (N) g' COPPER GROUND ROD, 8 FT LONG, AT LEAST 6' APART FROM (E) GROUND ROD. GEC INSTALLED PER NEC 250.64: 4 AWG SOLID COPPER "OR* 6 AWG SOLID COPPER GEC PROTECTED BY RMC/PVC/EMT INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12]. (1) 12 - 2 OF -B (or NM) W/G, THHN/THWN-2, SC MAX 10.0 A 2 OR 12-2 TC-ER,THHN/THWN-2, CU., 90C 240 V Enphase IQ Combiner 3 X -I Q -AM 1-240-3 (SOLAR LOADS ONLY) N (N)2 G kL:� I NTERIO "JUNCTION BOX(S) FOR WIRE SPLICING ONLY - OPTIONAL IF Q -CABLE (TC -ER) OR OF -B USED FOR ENTIRE HOMERUN JUNCTION BOX JUNCTION BOX FL, n L, �(1) 12-2TC-ER,THHN/THWN-2,CU. MAX 10.0AAC 1 (1) 6 AWG BARE, CU (EGC) 240 V AC Approval Notes: 1) P/V array system to have grounding system installed per Part III of Article 250 per 2017 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2017 NEC Article 250.53(A)(3). 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(6) EXTERIOR (10) Trina 320 UL 1703 COMPLIANT (10) Enphase IQ7 Microinverters MICRO INVERTERS UL 1741 COMPLIANT 10 MODULES MAX FOR ALL SUB -BRANCH CIRCUITS) TO COMPLY WITH VRIS CALCS (1) CIRCUIT OF 10 MODULES C" of 0 '4%W BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME ELEC. 3 LINE DIAG PAGE NUMBER REVISION PV5 0 C.) N r r) O 0 O N M Z C 0 0 o N U U U) N< (D I1_ C: LL'q: C2 - LLIG Z N U) CULL uJ 70 CU U) N U) J M > 0 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME ELEC. 3 LINE DIAG PAGE NUMBER REVISION PV5 0 MODULE SPECIFICATIONS Trinasolar 32UTSM-DD06M.05(I I) RATED POWER (STC) 320 W MODULE VOC 40.3 V DC MODULE VMP 33.4 V DC MODULE IMP 9.58 A DC MODULE ISC 10.2 A DC VOC CORRECTION -0.26 %/°C VMP CORRECTION -0.36 %/°C SERIES FUSE RATING 20 A DC ADJ. MODULE VOC @ ASHRAE LOW TEMP 44.4 V DC ADJ. MODULE VMP @ ASHRAE 2% AVG. HIGH TEMP 28.6 V DC IVIILnvlly V LR I LR )rLL.IFI%-M I I VIVJ LI1PI1=I%.(/ IVIII-1 U1IIVCI LC13 POWER POI NTTRACKING (MP PT) MIN/MAX 22 - 48 V DC MAXIMUM INPUT VOLTAGE 48 V DC MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC MAXIMUM USABLE DC INPUT POWER 350 W MAXIMUM OUTPUT CURRENT 1 A AC AC OVERCURRENT PROTECTION 20 A MAXIMUM OUTPUT POWER 240 W CEC WEIGHTED EFFICIENCY 97% AC PHOTOVOLATIC MODULE MARKING (NEC 690.52) NOMINAL OPERATING AC VOLTAGE 240 V AC NOMINAL OPERATING AC FREQUENCY 47 - 68 HZ AC MAXI MUM AC POWER 240 VA AC MAXI MUM AC CURRENT 1.0 A AC MAXI MUM OCPD RATING FOR AC MODULE 20 A AC DESIGN LOCATION AND TEMPERATURES TEMPERATURE DATA SOURCE ASHRAE 2% AVG. HIGH TEMP STATE Colorado CITY Wheat Ridge WEATHER STATION SALISBURY WICOMICO CO AP ASHRAE EXTREME LOW TEMP (-C) -14 ASHRAE 2% AVG. HIGH TEMP (-C) 33 SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 NUMBER OF MODULES PER MPPT DC POWER RATING PER CIRCUIT (STC) TOTAL MODULE NUMBER STC RATING OF ARRAY AC CURRENT @ MAX POWER POINT (IMP) MAX. CURRENT (IMP X 1.25) OCPD CURRENT RATI NG PER Cl RCUIT MAX. COMB. ARRAY AC CURRENT (IMP) MAX. ARRAY AC POWER 10 3200 COND. JRISE(V) VEND(V; %VRISE IQ7-1C VRISE SEC. 1(MICRO TO JBOX) 36 12 Cu. 10 MODULES 320OW DC 10.0 12.5 20 VRISE SEC. 2 (J BOX TO COMBINER BOX) 30 12 Cu. 1.21 241.21 10.0 F 240OW AC AC VOLTAGE RISE CALCULATIONS DIST (FT) COND. JRISE(V) VEND(V; %VRISE IQ7-1C VRISE SEC. 1(MICRO TO JBOX) 36 12 Cu. 1.45 241.45 0.61% VRISE SEC. 2 (J BOX TO COMBINER BOX) 30 12 Cu. 1.21 241.21 0.51% VRISE SEC. 3 (COMBINER BOX TO POI) 10 10 Cu. 0.25 240.25 0.11% TOTALVRISE 12.5 JUNCTION BOX TO 2.92 242.92 1.22% PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL (NEC 690.54) AC OUTPUT CURRENT 10.0 A AC NOMI NAL AC VOLTAGE 240 V AC GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690-47] AND [NEC 250-50] THROUGH [NEC 250-60] SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64C.]. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED. 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO [NEC 690.45] AND BEA MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE (#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF #4 AWG OR LARGER) 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM #8AWG WHEN INSULATED, #6AWG WHEN EXPOSED TO DAMAGE. 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR) 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 4. UV RESISTANT CABLE TIES(NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A -B). 300.4 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE -2, AND SINGLE -CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC -ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC CONDUCTOR SIZE CALCULATIONS MICROINVERTER TO MAX. SHORT CIRCUIT CURRRENT (ISC) = 10.0 A AC JUNCTION BOX (1) MAX. CURRENT (ISC X1.25) = 12.5 A AC CONDUCTOR (TC -ER, COPPER (90°C)) = 12 AWG CONDUCTOR RATING = 30 A AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 28.8 > 12.5 JUNCTION BOX TO MAX. SHORT Cl RCUIT CURRRENT (ISC) = 10.0 A AC JUNCTION BOX (2) MAX. CURRENT (ISC X1.25) = 12.5 A AC CONDUCTOR (UF -B, COPPER (60°C)) = 12 AWG CONDUCTOR RATING = 20 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 19.2 > 12.5 JUNCTION BOX TO MAX. SHORT Cl RCUIT CURRRENT (ISC) = 10.0 A AC COMBINER BOX (3) MAX. CURRENT (ISC X1.25) = 12.5 A AC CONDUCTOR (UF -B, COPPER (60-C)) = 12 AWG CONDUCTOR RATING = 20 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 19.2 > 12.5 COMBINER BOX TO INVERTER RATED AMPS = 10.0 A AC MAIN PV OCPD (15) MAX. CURRENT (RATED AMPS X1.25) = 12.5 A AC CONDUCTOR (THWN-2, COPPER (75-C TERM.)) = 10 AWG CONDUCTOR RATING = 35 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 33.6 > 12.5 690.8] FOR MULTIPLE CONDUCTORS 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8" ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (13)(2)(a), NEC TABLE 310.15(13)(3)(a),& NEC 310.15(13)(3)(c)]. 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE -2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V 11. 4 -WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY EUTRAL- WHITE/GRAY * USE -2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE ** USE -2 IS AVAILABLE AS UV WHITE 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH NEC 230.6(4) AND SECURED NO GREATER THAN 6' APART PER NEC 330.30(8). '4%W BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 Cu U N Cu W 70 J N U) O LL 00N N M V 00 O 70 Cu _O O U N 0) 70 Cu N M W N_ U) LU U) U 0 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME ELEC. CALCS. PAGE NUMBER REVISION PV6 0 S!WARNING. ELECTRIC SHOOK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED .-:,. IN THE OPEN POSITION r_ DIRECT PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE VDC MAX CIRCUIT CURRENT AMPS PHOTOVOLTAIC 1 AC DISCONNECT RATED AC OUTPUT CURRENT A NOMINAL OPERATING AC VOLTAGE V LABEL 1 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B), NEC 705.22] LABEL 2 AT EACH DC DISCONNECTING MEANS, INCLUDING THE DC DISCONNECT AT THE INVERTER. [NEC 690.53, NEC 690.13(B)] LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] AWARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVEROLIRRENT DEVICE I AWARNING I THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCU RRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. PHOTOVOLTAIC SYSTEM CONNECTED PV AC DISCONNECT LABEL 5 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(b)] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE �\ 'OFF POSITION TO Sa.ARPEL SHUTDOWN PV SYSTEM PVPANE�: IC AVD REDUCE SHOCK HAZARD IN THEARRAY LABEL 4 /,� �f I N NNECTING r : ■ YARN INSTALLL TOH S LABEL ANOYWHERETHEOAD HATI S TOTHE 'OFF POSITION POWERED BY BOTH THE UTILITY AND THE DUAL POWER SUPPLY SOLAR PV SYSTEM: THE MAIN SERVICE PANEL SQURCES- UTILITY GRID AND AND SUB -PANELS. PV SOLAR ELECTRIC SYSTEM [NEC 705.12(B)(3)] AWARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVEROLIRRENT DEVICE I AWARNING I THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCU RRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. PHOTOVOLTAIC SYSTEM CONNECTED PV AC DISCONNECT LABEL 5 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(b)] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE �\ 'OFF POSITION TO Sa.ARPEL SHUTDOWN PV SYSTEM PVPANE�: IC AVD REDUCE SHOCK HAZARD IN THEARRAY LABEL 7 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 1 OFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 8 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 9 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(B)] LABEL 11 SIGN LOCATED AT AC COMBINER BOX FOR ALL MICRO -INVERTER /AC MODULE INSTALLS (IF APPLICABLE). RAPID SHUTDOWN TEST NOT REQUIRED LABELING DIAGRAM FOR MICRO INV.: MAIN SERVICE PANEL LABEL 6 (ONLY IF 3 OR MORE SUPPLY SOURCES TO 12 A BUSBAR) SIGN LOCATED AT LOAD CENTER IF IT CONTAINS 3 OR MORE POWER SOURCES. 0 0 [NEC 705.12(13)(2)(3)(C)] 000 LABEL 10 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. LABEL 12 PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. LABEL 13 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY. LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 0&0 IF BREAKER USED 15 OR 17 OR PLACARD O (ONLY IF PV INTERCONNECTION CONSISTS OF LOA[ SIDE BREAKER) LABEL 15 ®WARMW I PERMANENT DIRECTORY TO BE LOCATED AT TURN RAPID SHUTDOWN SWITCH MAIN SERVICE EQUIPMENT LOCATION IF ALL TOTHE 'OFF POSITION ELECTRICAL POWER SOURCE DISCONNECTING TO SHUT DOWN CONDUCTORS MEANS SOLAR ARRAY RAPID SHUTDOWN OUTSIDETHEARRAY SWITCH) ARE GROUPED AND IN LINE OF SITE OF CONDUCTORS WITHIN MAIN SERVICE DISCONNECTING MEANS. THE ARRA" REMAIN [NEC 690.56(C) & NEC 705.10]. ENERGIZED IN SUNLIGHT m LABEL 7 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 1 OFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 8 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 9 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(B)] LABEL 11 SIGN LOCATED AT AC COMBINER BOX FOR ALL MICRO -INVERTER /AC MODULE INSTALLS (IF APPLICABLE). RAPID SHUTDOWN TEST NOT REQUIRED LABELING DIAGRAM FOR MICRO INV.: MAIN SERVICE PANEL LABEL 6 (ONLY IF 3 OR MORE SUPPLY SOURCES TO 12 A BUSBAR) SIGN LOCATED AT LOAD CENTER IF IT CONTAINS 3 OR MORE POWER SOURCES. 0 0 [NEC 705.12(13)(2)(3)(C)] 000 LABEL 10 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. LABEL 12 PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. LABEL 13 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY. LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 0&0 IF BREAKER USED 15 OR 17 OR PLACARD O (ONLY IF PV INTERCONNECTION CONSISTS OF LOA[ SIDE BREAKER) ®WARNING 99 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MAIN DISTRIBUTION UTILITY DISCONNECT LOCATED ®WARNING POWERTO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAY. SOLAR ARRAY RAPID SHUTDOWN DISCONNECT IS LOCATED OUTSIDE NEXT TO UTILITY METER. LABEL 16 PERMANENT DIRECTORY TO BE LOCATED AT SOLAR ARRAY RAPID SHUTDOWN SWITCH DENOTING THE LOCATION OF THE SERVICE EQUIPMENT LOCATION IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10] LABEL 17 PERMANENT DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION OF THE PV RAPID SHUTDOWN SYSTEM DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10, NEC 690.56(C)(1)] EXISTING SUB PANEL PV COMBINER (IF WHERE POINT OF SUBPANEL - INTERCONNECTION AC DISCONNECT IF USED TO COMBINE AC JUNCTION BOX IS MADE) (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS OR AC COMBINER BOX 01"Gmo o■to 13 10 O O&G4 16 O IF BREAKER USE 11 INTEGRATED DC DISCONNECT al& *ELECTRICAL DIAGRAMS SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. Ner... BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 LABEL 15 ®WARMW I PERMANENT DIRECTORY TO BE LOCATED AT MAIN DISTRIBUTION UTILITY DISCONNECT(S) MAIN SERVICE EQUIPMENT LOCATION IF ALL ELECTRICAL POWER SOURCE DISCONNECTING POWER TO THIS BUILDING ISALSOSUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY WITH MEANS SOLAR ARRAY RAPID SHUTDOWN A RAPID SHUTDOWN DISCONNECTING MEANS SWITCH) ARE GROUPED AND IN LINE OF SITE OF GROUPED AND LABELED WITHIN LINE OF SITE MAIN SERVICE DISCONNECTING MEANS. AND 10 FrOFTHIS LOCATION. [NEC 690.56(C) & NEC 705.10]. ®WARNING 99 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MAIN DISTRIBUTION UTILITY DISCONNECT LOCATED ®WARNING POWERTO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAY. SOLAR ARRAY RAPID SHUTDOWN DISCONNECT IS LOCATED OUTSIDE NEXT TO UTILITY METER. LABEL 16 PERMANENT DIRECTORY TO BE LOCATED AT SOLAR ARRAY RAPID SHUTDOWN SWITCH DENOTING THE LOCATION OF THE SERVICE EQUIPMENT LOCATION IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10] LABEL 17 PERMANENT DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION OF THE PV RAPID SHUTDOWN SYSTEM DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10, NEC 690.56(C)(1)] EXISTING SUB PANEL PV COMBINER (IF WHERE POINT OF SUBPANEL - INTERCONNECTION AC DISCONNECT IF USED TO COMBINE AC JUNCTION BOX IS MADE) (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS OR AC COMBINER BOX 01"Gmo o■to 13 10 O O&G4 16 O IF BREAKER USE 11 INTEGRATED DC DISCONNECT al& *ELECTRICAL DIAGRAMS SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. Ner... BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME LABELS PAGE NUMBER REVISION PV8 I 0 0 CN 7- 0 CN O 00 O N _0 Z CUM p i--' O N N U U U) LL LL q ZN U) CU LL LU CQ CU U) 70 N N > Q(n J M DRAWING BY DIN ENGINEERING DATE July 15, 2020 PROJECT NUMBER 76829518 SHEET NAME LABELS PAGE NUMBER REVISION PV8 I 0 Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters u� CERTIFIED To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro TM and Enphase IQ 7+ MicroTM dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy TM, Enphase IQ BatteryTM, and the Enphase Enlighten TM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60 -cell and 72 -cell* modules • More than a million hours of testing • Class II double -insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741 -SA) * The IQ 7+ Micro is required to support 72 -cell modules. Enphase IQ 7 and IQ 7+ M INPUT DATA (DC) Commonly used module pairings' Module compatibility Maximum input DC voltage Peak power tracking voltage Operating range Min/Max start voltage Max DC short circuit current (module Isc) Overvoltage class DC port DC port backfeed current PV array configuration OUTPUT DATA (AC) Peak output power Maximum continuous output power Nominal (L -L) voltage/range2 Maximum continuous output current Nominal frequency Extended frequency range AC short circuit fault current over 3 cycles Maximum units per 20 A (L -L) branch circuit3 Overvoltage class AC port AC port backfeed current Power factor setting Power factor (adjustable) EFFICIENCY Peak efficiency CEC weighted efficiency MECHANICAL DATA Ambient temperature range Relative humidity range Connector type Dimensions (HxWxD) Weight Cooling Approved for wet locations Pollution degree Enclosure Environmental category / UV exposure rating IQ7-60-2-US 235W -350W+ 60 -cell PV modules only 48V 27V -37V 16V -48V 22V/48V 15A 11 0A 1 x 1 ungrounded array; No additi AC side protection requires max: IQ 7 Microinverter 250 VA 240 VA 240V/ 208V/ 211-264 V 183-229 V 1.0 A (240 V) 1.15 A (208 V) 60 Hz 47-68 Hz 5.8 Arms 16 (240 VAC) 13 (208 VAC) III 18 mA 1.0 0.85 leading ... 0.85 lagging @240 V @208 V 97.6% 97.6% 97.0% 97.0% -40°C to +65°C 4% to 100% (condensing) MC4 (or Amphenol H4 UTX with additional Q -DCC -5 adapter) 212 mm x 175 mm x 30.2 mm (without bracket) 1.08 kg (2.38 lbs) Natural convection - No fans Yes PD3 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor FEATURES Nor - Communication BLUE RAVEN IQ7PLUS-72-2-US 235 W - 440 W + 6 60 -cell and 72 cell PV modules 1403 N RESEARCH WAY, BUILDING J The AC and DC connectors have been evaluated and approved by UL for use as the load -break OREM, UT 84097 60V Compliance 27V -45V 800-377-4480 16 V - 60 V WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL -THE INFORMATION 22V/60V 15A HEREIN CONTAINED SHALL NOT BE NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC USED FOR THE BENEFIT OF I I ANYONE EXCEPT BLUE RAVEN 0 A SOLAR NOR SHALL IT BE I DC side protection required; DISCLOSED IN WHOLE OR IN PART per branch circuit TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND IQ 7+Microinverter 295 VA USE OF THE RESPECTIVE 290 VA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE 240 V / 208V/ RAVEN SOLAR LLC. 211-264 V 183-229 V 1.21 A (240 V) 1.39 A (208 V) 60 Hz NABCEP Zf 47-68 Hz 5.8 Arms FCERTI 13 (240 VAC) 11 (208 VAC) PV INSTALLATION III PROFESSIONAL 18 mA Scott Gurney 1.0 # PV -011719-015866 0.85 leading ... 0.85 lagging CONTRACTOR- ONTRACTOR:97.5% @240 V @208 V 97.5%97.3% BRS FIELD OPS 97.0% 97.0% 385.498.6700 -40°C to +65°C 4% to 100% (condensing) MC4 (or Amphenol H4 UTX with additional Q -DCC -5 adapter) 212 mm x 175 mm x 30.2 mm (without bracket) 1.08 kg (2.38 lbs) Natural convection - No fans Yes PD3 Class II double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741 -SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES -0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v EN PHAS E• (D 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-01-06 EN PHASE® C"C* 7_2L =27)20 SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 Data Sheet Enphase Networking knphase IQ Combiner 3 (X-IQ-AM1-240-3) u� LISTED The Enphase IQ Combiner 3 T with Enphase IQ Envoy TM consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2 -pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular �1J • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple ■ To learn more about Enphase offerings, visit enphase.com • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2 -pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMAtype 3R enclosure • Five-year limited warranty • UL listed Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 IQ Combiner 3 with Enphase IQ EnvoyTM printed circuit board for integrated revenue grade PV X-IQ-AM1-240-3 production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile ConnectTM CELLMODEM-03 (4G/12 -year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5 -year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE -M/5 -year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring* CT Split core current transformers enable whole home consumption metering (+/- 2.5%). CT -200 -SPLIT * Consumption monitoring is required for Enphase Storage Systems Wireless USB adapter Installed at the IQ Envoy. For communications with Enphase EnchargeTM storage and Enphase COMMS -KIT -01 EnpowerTM smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ CombinerTM and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65A Max. fuse/circuit rating (output) 90A Branch circuits (solar and/or storage) Up to four 2 -pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV) 64A Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 lbs) Ambient temperature range -40° C to +46° C (-400 to 115° F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi Ethernet Cellular COMPLIANCE Compliance, Combiner Compliance, IQ Envoy 802.11 b/g/n Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE -M) (not included) UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) UL 60601-1/CAN CSA 22.2 No. 61010-1 To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the 00 !=k E N P H r rks of Enphase Energy, Inc. %.** ��U4 Nor - BLUE RAVEN F 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 city of SHEET NAME SPEC SHEET E N P H AS E® PAGE NUMBER REVISION SS 1 0 Mono Multi Solutions THE Residentolal.- MULTI-BUSBAR120 HALF -CELL BOB MODULE 1Z0 -Cell MONOCRYSTALLINE MODULE 310-335W POWER OUTPUT RANGE 19,70/o MAXIMUM EFFICIENCY O^j+5W POSITIVE POWER TOLERANCE Founded in 1997, Trina Solar is the world's leading total solution provider for solar energy. With local presence around the globe, Trina Solar is able to provide exceptional service to each customer in each market and deliver our innovative, reliable products with the backing of Trina as a strong, bankable brand. Trina Solar now distributes its PV products to over 100 countries all over the world. We are committed to building strategic, mutually beneycial collaborations with installers, developers, distributors and other partners in driving smart energy together. Comprehensive Products and System Certificates IEC61215/IEC61730/IEC61701/IEC62716 ISO 9001: Quality Management System ISO 14001: Environmental Management System IS014064: Greenhouse Gases Emissions Veriycation OHSAS 18001: Occupation Health and Safety Management System a 900 L Piro. om��� TVYxnei ii m..s C UL US LISTED C \ All k- � E Tinasolar PRODUCTSI BACKSHEET POWER COLOR RANGE TSM-DD06M.05(11) I Black I 310-335W Residential Module FRAME COLOR: Black 959 amePl�e High power output • Reduce BOS cost with high power bin and module efficiency �4� ,0'.Iing Hole e New cell string layout and split] -box location reduces the energy loss A 4 caused by inter -row shading Luu-B,x • Lower resistance of half -cut cells and increased MBB (Multi Busbar) reflectance ensure higher power 04.3 roundirg Hole 12 -Drain Hole High energy generation, low LCOE • Excellent 3rd art validated IAM and low light performance with cell m 1004 party 9 p Microinverter or Optimizer Configuration process and module material optimization 11.5 • Low Pmax temp coefficient (-0.36%)increases energy production Silicon Sealant Silicon Sealant8 LaminateLaminate • Better anti -shading performance and lower operating temperature ame Outstanding visual appearance, easy to install Frame Fr 35 24.5 A -A B -B • Designed for superior rooftop aesthetics I-V CURVES OF PV MODULE (335W) • Thinner wires give a eye cacthing all black look 11.0 • Safe and easy to transport, handle, and install 19.0 8.0 Certified to perform in highly challenging environment a6.0 600W/m 5.0 u 4.0 • High PID resistance through cell process and module material control 30 m 2.0 200W/m • Resistant to salt, acid, sand, and ammonia 1.0 • Over 30 in-house tests (UV, TC, HF etc) 0 10 20 30 40 50 Voltage(V) • Certified to 5400 Pa positive load and 2400 Pa negative load P -V CURVES OF PV MODULE (335W) 350 1000W/.2 PERFORMANCE WARRANTY 300 m 250 10 Year Product Warranty 25 Year Power Warranty 200 eoow/m= o150 400W/m' 100% 97.5% ■ Trina Standard 100 200W/m2 a 50 a 90% 0 10 20 30 40 50 m Voltage(V) C ° 83.1% t� 7 u Years 5 10 15 20 25 From the 2nd yearto the 25th year, the average annual powerdecline will be no more than 0.6%. • Tinnasolar MULTI-BUSBAR 120 HALF -CELL BOB MODULE ELECTRICAL DATA (STC) DIMENSIONS 250 OF PV MODULE(mm) 959 235 238 AL NamePlae 4-09x14 Installing Hole JA 604.3 Grounding Hole 12 -Drain Hole 310 m 1004 String Inverter Configuration FRAME COLOR: Black 959 amePl�e High power output • Reduce BOS cost with high power bin and module efficiency �4� ,0'.Iing Hole e New cell string layout and split] -box location reduces the energy loss A 4 caused by inter -row shading Luu-B,x • Lower resistance of half -cut cells and increased MBB (Multi Busbar) reflectance ensure higher power 04.3 roundirg Hole 12 -Drain Hole High energy generation, low LCOE • Excellent 3rd art validated IAM and low light performance with cell m 1004 party 9 p Microinverter or Optimizer Configuration process and module material optimization 11.5 • Low Pmax temp coefficient (-0.36%)increases energy production Silicon Sealant Silicon Sealant8 LaminateLaminate • Better anti -shading performance and lower operating temperature ame Outstanding visual appearance, easy to install Frame Fr 35 24.5 A -A B -B • Designed for superior rooftop aesthetics I-V CURVES OF PV MODULE (335W) • Thinner wires give a eye cacthing all black look 11.0 • Safe and easy to transport, handle, and install 19.0 8.0 Certified to perform in highly challenging environment a6.0 600W/m 5.0 u 4.0 • High PID resistance through cell process and module material control 30 m 2.0 200W/m • Resistant to salt, acid, sand, and ammonia 1.0 • Over 30 in-house tests (UV, TC, HF etc) 0 10 20 30 40 50 Voltage(V) • Certified to 5400 Pa positive load and 2400 Pa negative load P -V CURVES OF PV MODULE (335W) 350 1000W/.2 PERFORMANCE WARRANTY 300 m 250 10 Year Product Warranty 25 Year Power Warranty 200 eoow/m= o150 400W/m' 100% 97.5% ■ Trina Standard 100 200W/m2 a 50 a 90% 0 10 20 30 40 50 m Voltage(V) C ° 83.1% t� 7 u Years 5 10 15 20 25 From the 2nd yearto the 25th year, the average annual powerdecline will be no more than 0.6%. • Tinnasolar MULTI-BUSBAR 120 HALF -CELL BOB MODULE ELECTRICAL DATA (STC) 246 250 Maximum Power-PMAx (Wp) 235 238 Maximum Power Voltage-VMPP (V) Peak Power Watts-PMAx (Wp)* 310 315 320 325 330 335 Power Output Tolerance-PMAx (W) Short Circuit Current-Isc(A) 8.08 0 5 20oC, Wind Speed 1m/s. Maximum Power Voltage-VMPP (V) 33.0 33.2 33.4 33.6 33.8 34.0 Maximum Power Current-IMPP (A) 9.40 9.49 9.58 9.67 9.76 9.85 Open Circuit Voltage-Voc (V) 39.9 40.1 40.3 40.4 40.6 40.7 Short Circuit Current-Isc(A) 10.03 10.12 10.20 10.30 10.40 10.50 Module Efficiency TI m(%) 18.2 18.5 18.8 19.1 19.4 19.7 STC: Irradiance 1000W/m2, Cell Temperature Hoc, Air Mass AM 1.5. Measuring tolerance: +3%. ELECTRICAL DATA (NMOT) 246 250 Maximum Power-PMAx (Wp) 235 238 Maximum Power Voltage-VMPP (V) 31.0 31.2 Maximum Power Current-IMPP (A) 7.57 7.64 Open Circuit Voltage-Voc(V) 37.6 37.8 Short Circuit Current-Isc(A) 8.08 8.15 IN MOT: Irradiance at 800W/m2, Ambient Temperature 20oC, Wind Speed 1m/s. MECHANICAL DATA 242 246 250 254 31.4 31.6 31.7 31.9 7.71 7.79 7.86 7.94 38.0 38.1 38.3 38.4 8.22 8.30 8.38 8.46 Solar Cells Monocrystalline Cell Orientation 120 cells (6 X 20) Module Dimensions 1698 X 1004 X 35 mm (66.85X 39.53 X 1.38 inches) Weight 18.7kg (41.21b) Glass 3.2mm (0.13 inches), High Transmission, AR Coated Tempered Glass Encapsulant Material EVA Backsheet Black Frame 35 mm (1.38 inches) Anodized Aluminium Alloy ]-Box IP 68 rated Cables Photovoltaic Technology Cable 4.Omm2 (0.006 inchesz) Portrait: N 140mm/P 285mm (5.51/11.22 inches) Landscape: N 1200 mm /P 1200 mm (47.24/47.24 inches) Connector MC4 TEMPERATURE RATINGS MAXIMUM RATINGS N MOT(Nomina l Module OperatingTemperature) 41°C(±3°C) Operational Temperature -40-85°C Temperature Coefficient of PMAx - 0.360/o/°C Maximum System Voltage 1000V DC (IEC) Temperature Coefficient of Voc - 0.260/o/°C 1000V DC (UL) Temperature Coefficient of Isc 0.040/o/°C Max Series Fuse Rating 20A (Do not connect Fuse in Combiner Box with two or more strings in parallel connection) WARRANTY 10 year Product Workmanship Warranty 25 year Power Warranty (Please referto product warranty for details) PACKAGING CONFIGURATION Modules per box: 30 pieces Modules per 40'container: 780 pieces Nor - BLUE RAVEN F 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. SHEET NAME © 2019 Trina Solar Limited. All rights reserved. Speciycations included in this datasheet are subject to change without notice. SPEC SHEET Version number: TSM_DD06M.05(II)_EN_2019_B www.trinasolar.com PAGE NUMBER I REVISION S S 0 F 4 1 3 [198.37mm] 7.81 in 2 ITEM NO. PART NUMBER DESCRIPTION QTY. 1 JB -1 Body w/ E -Z LOK POLYCARBONATE WITH UV 1 [77.09mm] TECHNOLOGY INHIBITORS 2 JB -1 Lid w/ Gasket POLYCARBONATE WITH UV 1 INHIBITORS UNLESS OTHERWISE SPECIFIED: 3 10-32 x 1 " Phillips DIMENSIONS ARE IN INCHES pan head bolt 4 #8x 1-1/4" Phillips 4 pan head screw FRACTIONAL -CHECKED due Specification: tifications: ght (LBS): PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: COMMENTS: THE INFORMATION CONTAINED IN THISMATERIAL DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART ORAS A WHOLE FINISH WITHOUT THE WRITTEN PERMISSION OF NEXT ASSY USED ON <INSERT COMPANY NAME HERE> IS PROHIBITED. APPLICATION DO NOT SCALE DRAWING K 15-20 lbs -in UL Standard 1741, NEMA3R 1.3 lbs NAME I DATE EZ Solar SLC, UT USA Phone (385) 202-4150 www.ersolarproducts.com TITLE: EZ SOLAR SIZE DWG. NO. REV JB -1 SCALE: 1:2 (WEIGHT: I SHEET 1 OF 3 1 Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE B WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 0 C" of SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 [24.81 mm] .98in [77.09mm] 3.04in UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES DRAWN TOLERANCES: FRACTIONAL -CHECKED ENG APPR. ANGULAR: MACH± BEND ± TWO PLACE DECIMAL ± MFG APPR. THREE PLACE DECIMAL ± INTERPRET GEOMETRIC Q.A. PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: COMMENTS: THE INFORMATION CONTAINED IN THISMATERIAL DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART ORAS A WHOLE FINISH WITHOUT THE WRITTEN PERMISSION OF NEXT ASSY USED ON <INSERT COMPANY NAME HERE> IS PROHIBITED. APPLICATION DO NOT SCALE DRAWING K 15-20 lbs -in UL Standard 1741, NEMA3R 1.3 lbs NAME I DATE EZ Solar SLC, UT USA Phone (385) 202-4150 www.ersolarproducts.com TITLE: EZ SOLAR SIZE DWG. NO. REV JB -1 SCALE: 1:2 (WEIGHT: I SHEET 1 OF 3 1 Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE B WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 0 C" of SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 [304. 12. 0 F1 7n 7gmml 2 1 1 n 10.50i n 3 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART NEXT ASSY USED ON OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. APPLICATION [57.94mm] 2.28in [9.53mm] 0.38in [5.55mm] 0.22in SECTION A -A SCALE 1 : 1 UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL -CHECKED ANGULAR: MACH BEND # TWO PLACE DECIMAL ± THREE PLACE DECIMAL # DRAWN ENG APPR. MFG APPR. INTERPRET GEOMETRIC TOLERANCING PER: Q.A. COMMENTS: MATERIAL I DO NOT SCALE DRAWING 2 Frr, RQmml [57.94mm] 2.28i n NAME DATE TITLE: EZ SOLAR SIZE DWG. NO. REV 6 JB -1 WEI SCALE: 1.2 GHT: SHEET 2 OF 3 1 Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf FNABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 cry at `1 SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 0 Cl SECTION A -A SCALE 1 :2 3.18mm .13in LID OVERHANG OUTSIDE A f I 4 3 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF <INSERT COMPANY NAME HERE> IS PROHIBITED. -nm] n [22.23 m m] .88in NEXT ASSY I USED ON APPLICATION 2 I 1 INSIDE UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL -CHECKED ANGULAR: MACH± BEND ± TWO PLACE DECIMAL ± THREE PLACE DECIMAL ± DRAWN ENG APPR. MFG APPR. INTERPRET GEOMETRIC TOLERANCING PER: Q.A. COMMENTS: MATERIAL 2 DO NOT SCALE DRAWING NAME I DATE TITLE: EZ SOLAR SIZE DWG. NO. REV 6 JB -1 SCALE: 1:2 (WEIGHT: SHEET 3 OF 3 1 Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLU ERAVENSOLAR. COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE B WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf FNABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 0 SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 SUN SYSTEM BONDING & GROUNDINGNor- BLUE mom ; a11 FRAME '" RAVEN ■■ FM MICRORAILINSTALLATION GUIDE ; PAGE b aaEM�,��,BUILDINGJ S Star Washer is Single Use Only TERMINALTOROUE, Install Conductor and torque to the followir 4-6 AWG: 35in-lbs 8 AWG: 25 in -lbs 10-14 AWG: 20 in -lbs TERM I NAL TOROU E, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs WEEBLUG Single Use Only 00!� TERMINAL TORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Rsco Lay -In Lug (GBL-4DBT) Ilsco Flange Lug(SGB-4) Wiley WEEBLug (6.7) • 10-32 mounting hardware 0 1/4" mounting hardware 0 1/4" mounting hardware • Torque = 5 ft -lb 0 Torque = 75 in -lb 0 Torque = 10 ft -lb • AWG 4-14 - Solid or Stranded 0 AWG 4-14 - Solid or Stranded 0 AWG 6-14 - Solid or Stranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module at a location on the module specified by the module manufacturer. E -W BONDING PATH: E -W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicroraiLTM and splice. Alternate method N -S BONDING PATH: N -S module to module bonding is accomplished with bonding clamp with 2 integral bonding pins. (refer also to alternate method ) a Alternate method TRIMRAIL BONDING PATH: Trimrail to module bonding is accomplished with bonding clamp with integral bonding pin and bonding T -bolt. (refer also to alternate method 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP FCERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NUMBER I REVISION SS 0 ■■ $�M SUN UL CODE COMPLIANCE NOTES R MM MICRORAIL'" INSTALLATION GUIDE ;PAGE --------------------------------------------------------------------------------------------------------------------------------------------- SVSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to the system level fire portion of UL 1703. This UL 1703 classification has been incorporated into the UL 2703 product certification. SFM has achieved Class A, B & C system level performance for low slope & steep sloped roofs when used in conjunction with type 1 and type 2 modules. Class A, B & C system level fire performance is inherent in the SFM design, and no additional mitigation measures are required. The fire classification rating is valid for any roof pitch. There is no required minimum or maximum height limitation above the roof deck to maintain the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILTm components shall be mounted over a fire resistant roof covering rated for the application. Module Type Roof Slope Type 1 and Type 2 steep Slope & Low Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Landscape OR Portrait None Required Class A, B & C East-West UL2703 TEST MODULES See page "S" for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 22.3 sgft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF / 5400 Pa b) Upward Pressure - 50 PSF / 2400 Pa C) Down -Slope Load - 30 PSF / 1400 Pa • Tested Loads: a) Downward Pressure - 170 PSF / 8000 Pa b) Upward Pressure - 75 PSF / 3500 Pa C) Down -Slope Load - 45 PSF / 2100 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE -001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span LABEL MARKINGS • System fire class rating: See installation instructions for installation requirements to achieve a specified system fire class rating with Unirac . • Unirac SUNFRAME MICRORAILTm is listed to UL 2703. • All splices within a system are shipped with marking indicating date and location of manufacture. Itis I ria WD nu hm" in lr3 LA W � 0 iLi3��f'�i N4QYRlW.3[ iii3l �'�+ � � • o.i yrv-smaW&M OWE MJKLI�s MWw�ti iii�l limed � &S IMQL sham �N� 0 2 K.:A," i r 6 111 1 a i t a r 15 r t I III Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NUMBER I REVISION SS 0 NIo I $�M FUNMEMTESTED / CERTIFIED MODULE LIST s MM MICINSTALLATION GUIDE ;PAGE --------------------------------------------------------------------------------------------------------------------------------------------- Manufacture I Module Model /Series Aleo P -Series CHSM6612P, CHSM6612P/HV, CHSM6612M, Astronergy CHSM6612M/HV, CHSM6610M (BL)(BF)/(HF), CHSM72M-HC Auxin AXN6M610T, AXN6P610T, AXN6M612T & AXN6P612T AXI Power, AXI Premium, AXI Black Premium BVM6610, BVM6612 P6K & MHK-36 Series Axitec Boviet BYD CS6V-M, CS6P-P, CS6K-M, CS5A-M, CS6K-MS, CS6U-P, CS6U-M, CS6X-P, CS6K-MS, CS6K-M, CS6K-P, CS6P-P, CS6P-M, CS3U-P, Canadian Solar CS3U-MS, CS3K-P, CS3K-MS, CS1K-MS, CS3K, CS3U, CS3U-MB-AG, CS3K-MB-AG, CS6K, CS6U, CS3L, CS3W, CS1H-MS, CS1U-MS Centrosolar America C -Series & E -Series CT2xxMxx-01, CT2xxPxx-01, Trina CertainTeed CTxxxMxx-02, CTxxxM-03, Vikram CTxxxMxx-04, CTxxxHC11-04 DH -60M Orion 1000 & Apollo 1000 Dehui Eco Solargy FreeVolt Mono PERC GCL-P6 & GCL-M6 Series GCL TD-AN3, TD-AN4, Hansol U13-AN1, UD-AN1 Heliene 36M, 60M, 60P, 72M & 72P Series HT Solar HT60-156(M) (NDV) (-F), HT 72-156(M/P) KG, MG, TG, RI, RG, TI, MI, HI & KI Series Hyundai ITEK iT, iT-HE & iT-SE Series Japan Solar JPS -60 & JPS -72 Series Manufacture JA Solar Jinko Kyocera LG Electronics LONGi Mission Solar Energy Mitsubishi Neo Solar Power Co. Panasonic Peimar Phono Solar O.Cells Module Model/ Series JAP6 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ xxx, JAP6(k)-72-xxx/4BB, JAP72SYY-xxx/ZZ, I JAP6(k)-60-xxx/4BB, JAP60SYY-xxx/ZZ, JAM6(k)-72-xxx/ZZ, JAM72SYY-xxx/ZZ, JAM6(k)-60-xxx/ZZ, JAM60SYY-xxx/ZZ. i. YY: 01, 02, 03, 09,10 ii. ZZ: SC, PR, BP,HiT,IB,MW JKM & JKMS Series KU Series LG xxx S1 C -A5, LG xxx N 1 C -A5, LGxxxO1C(01K)-A5, LGxxxN1C(N1K)-A5, LGxxxS1CA5, LGxxxA1C-A5, LGxxxN2T-A4, LGxxxN2T-A5, LGxxxN2W-A5 LGxxxS2W-A5, LGxxxE1C-A5, LGxxxS2W-G4 LGxxxN1C(N1K)-G4, LGxxxN2W-G4, LGxxxS1C-G4, LGxxxE1K-A5, LGxxxN2T-J5, LGxxxN1K(N1C)-V5, LGxxxO1C(N2W)-V5, LR6-60 & LR6-72 Series, LR4-60 & LR4-72 Series MSE Series MJE & MLE Series Manufacture REC Renesola Risen S -Energy Seraphim Sharp Silfab Solaria SolarWorld Sonali Suntech Suniva Sun Edison/Flextronics SunPower D6M & D6P Series I I Talesun VBHNxxxSA15 & SA16, VBHNxxxSA17 & SA18, VBHNxxxSA17(E/G) & SA18E, VBHNxxxKA01 & KA03 & KA04, VBH NxxxZA01, VBH NxxxZA02, V13 NxxxZA03, V13 NxxxZA04 SGxxxM (FB/BF) PS -60, PS -72 Plus, Pro, Peak, G3, G4, G5, G6(+), G7, G8(+) Pro, Peak L -G2, L -G4, L -G5, L -G6, L -G7 Tesla Trina Upsolar URE Vikram Waaree Winaico Yingli Module Model/ Series PEAK Energy Series, PEAK Energy BLK2 Series, PEAK Energy 72 Series, TwinPeak 2 Series, TwinPeak 2 BLK2 Series, TwinPeak Series Vitrus2 Series & 156 Series RSM Series SN72 & SN60 Series (40mm) SEG -6 & SRP -6 Series NU -SA & NU -SC Series SLA, SLG & BC Series Powe rXT Sunmodule Protect, Sunmodule Plus SS 230 - 265 STP MV Series & Optimus Series F -Series, R -Series & FLEX FXS Series X -Series, E -Series & P -Series TP572, TP596, TP654, TP660, TP672, Hipor M, Smart SC, SC B, SC 131, SC 132 PA05, PD05, DD05, DE06, DD06, PE06, PD14, PE14, DD14, DE14, DE15, PE15H UP-MxxxP(-B), UP-MxxxM(-B) D7MxxxH8A, D7KxxxH8A, D7MxxxH7A Eldora, Solivo, Somera AC & Adiya Series WST & WSP Series YGE & YLM Series Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET Please see the SFM UL2703Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM. SFM Infinity is not compatible with module frame height of less than 32mm and more than 40mm. See page J for further information. PAGE NUMBER REVISION SS 0 Intertek Total Quality. Assured. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: vitertek Total Quality. Assured. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA ,. Control Number: 5003705 Authorized by: for L. Matthew Snyder, Certification Manager OSTEIDT C us Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 1411 Broadway Blvd NE Standard(s): Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed. 1] 1411 Broadway Blvd NE Photovoltaic Module Racking Systems [CSA LTR AE -001:2012 Ed.2012/10/23] Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Address: Country: USA Country: Country: USA Country: Klaus Nicolaedis Klaus Nicolaedis Contact: Todd Ganshaw Contact: Contact: Todd Ganshaw Contact: 505-462-2190 505-462-2190 Phone: 505-843-1418 Phone: Phone: 505-843-1418 Phone: FAX: NA FAX: FAX: NA FAX: klaus.nicolaedis@unirac.com klaus.nicolaedis@unirac.com Email: toddg@unirac.com Email: Email: toddg@unirac.com Email: Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA ,. Control Number: 5003705 Authorized by: for L. Matthew Snyder, Certification Manager OSTEIDT C us Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2 -Jun -2020 ED 16.3.15 (20 -Apr -17) Mandatory Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA ,. Control Number: 5003705 Authorized by: for L. Matthew Snyder, Certification Manager OT C us ISTE Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed. 1] Photovoltaic Module Racking Systems [CSA LTR AE -001:2012 Ed.2012/10/23] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2020MAY04 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2 -Jun -2020 ED 16.3.15 (20 -Apr -17) Mandatory Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA ,. Control Number: 5003705 Authorized by: for L. Matthew Snyder, Certification Manager OT C us ISTE Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2 -Jun -2020 ED 16.3.15 (20 -Apr -17) Mandatory Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 city of N �' U)44� SHEET NAME SPEC SHEET PAGE NUMBER I REVISION SS O Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed. 1] Photovoltaic Module Racking Systems [CSA LTR AE -001:2012 Ed.2012/10/23] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2020MAY04 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2 -Jun -2020 ED 16.3.15 (20 -Apr -17) Mandatory Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 city of N �' U)44� SHEET NAME SPEC SHEET PAGE NUMBER I REVISION SS O NMI � $FM FRAME SME YSTEM COMPONENTS P MM MICRORAIL TM INSTALLATION GUIDE ; PAGE --------------------------------------------------------------------------------------------------------------------------------------------- —35 I \__FL_J �r TrimraiLT" and Module Clips Sub -Components: 1. Trim Rail 2. Module Clip 3. T -Bolt 4. Tri -Drive Nut TrimraiLTM Functions: • Required front row structural support (with module clips) • Module mounting • Installation aid • Aesthetic trim Features: • Mounts directly to L -feet • Aligns and captures module leading edge • Supports discrete module thicknesses from 32, 33, 35, 38, and 40mm Module Clips Functions: • Required front row structural support (with trimrail) • Module mounting Features: • Mounts to TrimraiLT"' with T -bolt and tri -drive nut • Manually adjustable to fit module thicknesses 32, 33, 35, 38, and 40mm. 140 TrimraiLTm Flashkit Sub -Components: L -Foot Hex bolt Tri -drive nut Channel Nut Scocket Head Cap Screw 3"Channel/Slider w/grommet 3" Wide Flashing Structural Screw & SS EPDM Washer Functions: • Attach TrimraiLTm to roof attachment/flashing • Patented roof sealing technology at roof attachment point Features: • Slot provides vertical adjustments to level array • Slider provides north/south adjustment along the slope of the roof • Shed and Seal Technology TrimraiLTM Splice Sub -Components: 1. Structural Splice Extrusion 2. Bonding Clip Functions: • Front row structural support • Installation aid • Structurally connects 2 pieces of TrimraiLT"' • Electrically bonds 2 pieces of TrimraiLT"' Features: • Aligns and connects TrimraiLT"' pieces • Tool -less installation Nel BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 SON SYSTEM COMPONENTS , o Nor- ME ■! FRABLUE RAVEN ■■ SFM MICRORAILTM INSTALLATION GUIDE ;PAGE b aaEM�,��, N„J --------------------------------------------------------------------------------------------------------------------------------------------- 800-377-4480 SFM Slider Flashkit Sub -Components: 1. Slider w/grommet 2. Structural Screw & SS EPDM washer 3. 3" Wide Flashing Functions: • Patented Shed & Seal roof sealing technology at roof attach- ment point • For use with compatible 2" Microrail or 8" Attached Splices Features: • Slider provides north/south adjustment along the slope of the roof • Shed and Seal Technology Module -to -Module N -S Bonding Sub -Components: 1. Clamp 2. Bonding Pins (2) 3. 5/16" Socket Head Cap Screw 4. Clamp Base Functions/ Features: • Row to row bonding • Single Use Only • Fits module sizes 32-40mm Trim -to- Module Bonding Clamp and Floating Trim Clamp Sub -Components: 1. Wedge 2. Bonding Pin 3. T -Bolt 4. Nut 5. Cast Base Functions/ Features: • Module to TrimraiLTm bonding - single use only • Attaches TrimraiLT"' to module when fewer than 2 rafter attachment points are available • Fits module sizes 32-40mm • Fits module sizes 32-40mm Wire Bonding Clip w/ 8AWG Functions: • Row to row bonding • Module to TrimraiLTm bonding • Single Use Only Features: Tool -less installation MLPE Mounting Assembly Sub -Components: 1. MLPE Mount Base 2. 5/16 Socket Head Cap Screw 3. Bonding Pin Functions: • Securely mounts MLPE to module frames • MLPE to module bonding Features: • Mounts easily to typical module flange • UL2703 Recognized MLPE = Module Level Power Electronics, e.g. microinverter or power optimizer CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NSS UMBER I REVISION 0 mn'M� I SFM FRAME 3n FLASHING & SLIDERS G MM MICRORAIL TM INSTALLATION GUIDE ;PAGE --------------------------------------------------------------------------------------------------------------------------------------------- PILOT HOLES: Drill pilot holes for lag screws or structural screws (as necessary) at marked attachement points FLASHINGS: Place flashings INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: • Insert flashings per manufacturer instructions NOTE: Use Lag screw or structural fastener with a maximum diameter of 5/16" • Attach sliders to rafters • Verify proper row to row spacing for module size (Mod NS + 1") • Ensure that TrimraiLTM roof attachments in each row have sufficient engagement with slider dovetails for proper attachment. INSTALL SLIDERS AND ROOF ATTACHMENTS: Follow manufacturer instructions for flashing installation procedures NOTE: If N -S module edge is within 1" of the shingle course above, you have the option to pivot / rotate slider at the attachment point to span the next course and cut shingles as required. Cut Shingles as Required II µ8 1 µ 1 I 1 1 Rotate Slider • Nor - BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. Zf NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NUMBER I REVISION SS D "�o z INS EC ON RECO25(RD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/forms.aspx?fid=79 INSPECTION REQUEST LINE: (303) 234-5933 Occupancvi? )Me Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Initials Comments Pier Initials Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prinr Tn Onnrnval of Thn Ak, .,., Rough Inspections - - - - rr•- 1111...--."Wv'u 111111,�NV%,UU1Ia Inspector Underground/Slab Inspections Date Comments Wall Sheathing Initials Electrical Sewer Service Plumbing Lath / Wall Tie Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof a q > �� Final Window/Doors Final Building FNOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate f Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *Fnr Inw vnit2no ncrmi4c — Dlonn G �.. ♦L a _ .._� :___ pl—U n Uu i u is Flit; LAZAI t dnw elecincal IOW Voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 9 o cl - 4' 11611 1 Job Address: -33-3-3 F',c n „ S 4 - Permit Number: a 0 17 0 a a 5' ) 10AI ❑ No one available for inspection: Time a = 7 AM/& Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: -,) //? Inspector: Tb DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _��9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �J o4 — r=- f 11 a 1 Job Address: _1 3 a 3 �7e') -k®,\ S+ Permit Number: a o 1-7 o as S—) \j c a A re Ual o n V e r"r n/ V S /nog ❑ No one available for inspection: Time ) L'= 331 AWPM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303-234-5933 Dater/ ) 1 '9 Inspector: '7--b DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201702251 PERMIT NO: 201702251 ISSUED: 06/20/2017 JOB ADDRESS: 3223 Fenton ST EXPIRES: 06/20/2018 JOB DESCRIPTION: RESIDENTIAL RE-ROOF W/ OWENS CORNING STORM ASPHALT SHINGLES - 23.91 SQ. *** CONTACTS *** OWNER (303)233-6436 GARDNER CARMEN B GC (303)761-6400 J. Bretz 018118 Excel Roofing, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,611.85 FEES Total Valuation 0.00 Use Tax 222.85,#T Permit Fee 220.15`/ " * * TOTAL * * 443.00 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2-inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€Tms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201702251 PERMIT NO: 201702251 ISSUED: 06/20/2017 JOB ADDRESS: 3223 Fenton ST EXPIRES: 06/20/2018 JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM ASPHALT SHINGLES - 23.91 SQ. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and ani authorized to obtain this permit and perform the work described and approved in conjunction with this_permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work subject to fie kld inspection. Y Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Excel Roofing 3223 Fenton St Wheat Ridge CO 80212 We're on Top of It g ExcelRoofing.com EXCEL ROOFING.COMrmo� 4610 $ FEDERAL BLVD ENGLEWOOD CO 8o110 303.781.6400 Proposal/ Contract Date: 5/29/2017 Proposal submitted to: Carmen Gardner Address: 3223 Fenton St Wheat Ridge, CO 80212 Phone # : (303) 233-6436 Email: Carmengardner@hotmail.com Job Style: gable We hereby propose to furnish materials and labor necessary for the completion of: I. Installation of the; Owens Corning Duration Storm Limited Life - Class 4 Impact rated asphalt roof system installed per the manufactures recommendation Initial here: Color: Brownwood A. Provide Workman's Comp and Liability Insurance. (Acord Ins 303-762-1717) and Pinnacol ins. B. Obtain building permit from city or county. (cost not included) C. Provide Carbon Monoxide Alarm at start of project. D. Remove all layers of existing roofing, currently has: 1 E. Inspect Roof decking; $ 55 per sheet to replace if needed. F. Ensure that all eaves and gables have metal drip edge. brown G. Install New shingle underlayment(s) that meet or exceed code: Synthetic K Ensure all HVAC vents are properly flashed & painted. Install & paint new neoprene flashing on all plumbing vent pipes. 1. Install asphalt shingles to manufacturer's recommendations with VA inch galvanized nails, 6 nails per shingle. J. Attic ventilation: Excel Roofing recommends; R. Install matching ridge shingles. L. Final inspection with Project Manager at completion of project and call for final permit inspection II. Workmanship is guaranteed for Five (5) years. Free transfer to new owner. III. Excel Roofing will clean up, use nail magnet and haul all debris at completion of project. III. Excel Roofing will wash the roof at completion of project. Additional items: ... ➢ Roof cost includes house, shed, haul away/dump fee, roof jack/vent painting, and sales tax. Any and all Unforeseen Code Upgrades, Supplemental items and permit fee will be billed to the insurance company, if it is an insurance claim and the policy allows. Excel Project Manager: Bob Joyce Email: Bob@excelroofing.com Phone #: 303-905-1100 Excel Roofing ExcelRoofing.com 3223 Fenton St Wheat Ridge CO 80212 We're on Top of It Pages 1 of 2 jxcel Roofing 3223 Fenton St Wheat Ridge CO 80212 We're on Top of It IV. Home and Roof Options: Cost for removal and replacement of Roof, including all labor and materials. Replace 0 Feet of 5 inch gutter 0 Feet of D/S Color: Copper penny $ Cost to upgrade to a Limited Lifetime Class 4 impact rated shingle Cost for additional attic ventilation if needed; Cost to replace flat roof area with: Modified Bituman Color: N/A Cost to add 0 inches of blown in insulation on top of the existing attic insulation. Cost for any additional items noted on the 1st page of the contract. Payment Options: *Please initial next to the payment option of choice* A: Payment using Financing: *Payment plan options, WAC* Amount to be financed $ 12,255.09 *Please note that Excel does not make any additional money on these fees & loans Dealer # 11545 ph # 866-393-0033 12 Month 0% Deferred Interest 60 Months 7.99% interest 120 Months 7.99% interest ($1,021.26) ($248.43) ($148.62) ExcelRoofing.com 9,184.94 949.56 Free 1,426.91 Initials Initials Initials B: Payment Using Credit Card: Cost of Project if paid by credit card. This price reflects the 3% convenience fee $ 11,908.25 Initials C: Payment by cash, check or secured funds = $ 11,561.41 Initials plus permit fee Terms: 100% Payment due upon completion of each phase of work Total Cost does not include City/County Permit fee. According to Colorado law if the services provided are paid through an insurance claim it is illegal for a Contractor to pay the homeowner's deductible in whole or part, also any deposit paid by the Homeowner must be held in trust. The homeowner may cancel this contract at anytime prior to construction. If the material has been delivered or the permit has been purchased then the homeowner shall be obligated to pay the delivery and permit costs. The homeowner may also cancel this contract if they are notified that their claim is denied in whole or part. All work to be completed per standard industry practices according to specifications submitted. The homeowner agrees that if any additional work is required to complete the above specifications involving extra cost they will pay these additional charges. All agreements are contingent upon strikes, accidents, or delays beyond our control. Owner agrees to carry regular homeowners insurance. Excel Roofing will not be held liable for any structural movement, settling, cracks in drywall, damage to driveway, or any damage to siding due to the roofing or loading process. Finance charges of 1 Y2 percent per month will be added to any unpaid balance. In the event collection action is taken to recover payment under this agreement, Excel Roofing, Inc., should be entitled to reasonable collection and attorney fees and costs incurred in such action. Excel Roofing's liability insurer is Cincinnati Insurance Company, 6200 S. Gilmore Road, Fairfield, OH 45014-5141. This proposal may be withdrawn by Excel if not accepted within _7_days. The approximate start date shall be within_60_days of acceptance of this proposal. Bob Joyce Project Manager Date: 5/29/2017 Cell Phone # 303-905-1100 303-761-6442 Fax Acceptance of Contract The above price, specifications and conditions are satisfactory and are hereby accepted. Excel Roofing, Inc. is hereby authorized to do the work as specified and payment will be made to Excel Roofing, Inc., as outlined above. PiintedName Carmen Gardner Signature 6L&A A011 W ExcelRoofing.com 3223 Fenton St Wheat Ridge CO 80212 Homeowner 6f111:;L Excel Roofing We're on Top of It Pages 2 of 2 Kimberly Cook _�Z/ 7 6;�? From: no -reply@ ci.wheatridge.co.us Sent: Monday, June 12, 2017 1:52 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 3-5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address Do you have a signed contract to reroof this property? It will need to be provided at the time of permit pick-up. 3223 Fenton St Wheat Ridge, CO 80212 Carmen Gardner 303-233-6436 Field not completed. Yes CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Excel Roofing, Inc 018118 3037616400 Contractor Email Address excel@excelroofing.com (permit pick-up instructions will be sent to this email) Retype Contractor Email excel@excelroofing.com Address DESCRIPTION OF WORK Is this application for a new permit for a residential roof? Are you re -decking the roof? Description of Roofing Material Select Type of Material If "Other" is selected above, describe here: Yes No Owens Corning Storm shingle Asphalt Field not completed. How many squares of the 19.37 material selected above? Does any portion of the Yes property include a flat roof? If yes, how many squares 3.71 on the flat roof? TOTAL SQUARES of all 19.37 sq house, 3.71 sq modified porch, .83sq shed roofing material for this project � • � ( I b�`0 Provide additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) porch flat, rest of roof pitch is 4/12 10611.85 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant James Bretz Email not displaying correctly? View it in your browser. 3 s i CITY OF WHEAT RIDGE Vr _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303 235-2855 Office e(303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number:�j Ll No one available for inspection: Time JAM/P Re -Inspection required: Ye°� No When corrections have been made, call"for re -inspection at 303-234-5933 Date: / Inspector: )AI G/ 1&4-+ DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE ❑ No one available for inspection: Time ��='� ./ AM/PM Re -Inspection requireda Yes i No When corrections have been made, call forre-inspection at 303-234-5933 r ; Date: � v Inspector: l.� DO NOT REMOVE THIS NOTICE City of Wheat Ridge Community Development Department Memorandum TO: Accounting Department FROM: Melissa Mackey, Building Division SUBJECT: Refund for Permit DATE: September 16 2013 Reason: Contractor submitted request to have a portion of the work being performed (see attached sheet for details) removed from the permit for 3223 Fenton St., Permit #201300765. Please refund Contractors License$ 19.78% permit fee: $15.85 0% plan review $ 16.11 % use tax: $18.00 Total: TO: JO -D Enterprises, Inc. 6365 W. 46 Avenue Wheat Ridge, CO 80033 Thank You! ( $33.85 M M Permit Technician Jefferson County Housing Authority REQUEST FOR CHANGE OR" % ,,, Order No: 2 �/� Date: July 18, 2013 File No: WR141 HOME i This Change Order is a clarification and /or change to the original contract between: 1019 Property Owner CARMEN GARDNER 3223 FENTON STREET WHEAT RIDGE, CO 80033 Contractor JO -D ENTERPRISES, INC. 6365 WEST 46th AVENUE WHEAT RIDGE, CO 80033 This Change Order is made in order to modify, change or clarify the work under the above noted Contract and this order is made a part of the Contract. This change order shall supersede any previous drawings, change orders, specifications or agreements made regarding the work contained herein. The contractor is hereby rquested to comply with the following: Item Description Quantity/Unit Total Cost Group Change Orders 11 Change Order #2: - Delete Item #1 (Masonry- Window lintel Repair) -$390; and delete Item #5 (New Windows - bedroom) -$1860 = total deleted - $2,250 - Add: Include tuck pointing the brick around the West window, and re -tuck pointing the black and non - conforming brick on the West side = +$1,750 - Add to Item #8 (New A/C): Due to the need for more room to add the new coils to the existing furnace, the furnace needs to be lowered and the ductwork redone to accommodate the capacity for the new air conditioner unit. Unit is scheduled to be installed on July 23rd of 24th. = +$1,500 Total chanqe this C.O. #2 = +$1,000 1.00 JOB $1,000.00 Total Change $1,000.00 CONTRACTOR IS AUTHORIZED TO PROCEED WITH WORK SPECIFIED IN THIS CHANGE ORDER By agreeing to and signing this change order, Owner agress that the loan the Owner has with Jefferson County Housing Authority for this projecjt, will change by the amount of the Change Order late Rehab Specialist Date I ) OneRoof by Travis Systems, Inc. Page 1 of 1 Printed: 7/18/13 I / View Permit 201300765 Information Page 1 of 1 View Permit 201300765 Information Parcel: 39- 251 -19 -009 Address: 3223 Fenton ST, Wheat Ridge, CO 80212 Warning 1 11: Contractor 060021 Warning: MICROSCOPEII They don't call in inspections on time and called Phil Plummer who paid their same day inspection fee. Permit Parce! Notes Contacts Valuations Approvals Conditions Additional Required Inspections Receipts Parcel Inspections p Documents rPermit Valuations & Fees Master Maintenance l Total Valuation: 15,110.00 Permit Fees: 299.40 Use Tax: 271.98 Amount Paid: 605.23 Permit Valuation: 15,110.00 Other Fees: 0.00 Total: 571.38 Balance Due: 33.85 - Main Maintenance Filters Sorts snowing - i 10 o UT o rKewra5 Home Prev Next I End http: / /srv- ci- adm -01 /adg /adg /main.php ?POP =1 &recid= 65357 &run =c: /adg /web /apps/bps /b... 9/16/201 ") Valuation Creation Valuation Fee Code Description Date Amount Amount Use Tax Fee Paid Balance 10 USE Use Tax 06111/13 15,110.00 0.00 271.98 289.98 18.00 y PRM Permit Fee 06/11/13 15,110.00 299.40 0.00 315.25 15.85 - y TOTVA Total Valuation 06 111/13 15,110.00 0.00 0.00 0.00 0.00 0 USE Use Tax 06 111/13 15,110.00 0.00 271.98 289.98 18.00- snowing - i 10 o UT o rKewra5 Home Prev Next I End http: / /srv- ci- adm -01 /adg /adg /main.php ?POP =1 &recid= 65357 &run =c: /adg /web /apps/bps /b... 9/16/201 ") CITY OF Inspection r • Address: Number: Permit [Jim* fIfLijil ry Property Address: Property Owner (please print): Mailing Address: (if different than property address) Address: ZEMEBEEMBEM 0.Q Masoaru R o ar.° Remove all loose or damaged bricks s and eroded mortar at the chimney, crest and south sides of the main house and garage, properly twit point and reset all loose brick to a sound condition, Work areas shall be cleaned of all new mortar stains can masonry. (approx 100 sq.ft,) Doors ♦> 4 Remove,existing, and provide and install new door w/ halt lite (wl interior grids to match + insulated, panel installation, Include deadbolt look set, adjustable threshold, trim and site paint after adjustment is applicable wl C,O, if Owner selects Fiberglas door with operable window in 1/2 flte) 6 x.00 Windows 11 1 111111 1 •: " • • the 1/2, rear bath, Re-texture the patched areas of ceilings to match existing to paint-ready condition (Owner to do repainting), Also include patching bath to paint-ready I! ! JUN/ U ZU I V t h 1 1 U : �t_/ Ali! P. 009 Description of Work (Exhibit A) Project GARDNER, CARMEN w #' • New Air-OnditioLnO LLni Furnish and install anew air-conditioning unit installed in the existing it furnace system. Installation shall include all components for a complete installation, New unit shall be of adequate size to cool the existing square footage and shall be energy saving (14.5tier), Include new thermostat and proper connections. Provide Owner w/ certification of unit and installation as needed for the Xcel rebate program, Electrical = $ = � � 1C70i_tract Tot a1 Printed; 6/6/2013 2:01:03PM Page 8 of 8 A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE 71 Inspection Type T_r d1711 Job Address 7"nl l Permit Number /(1 iZ!2:� . No one available for inspection: Time ! �M/f?M Re- Inspection required: Yes No When corrections have been made, all for re- inspection at 303 - 234 -5933 Date: 44 � ) / T" Inspector: ,' DO NOT REMOVE THIS NOTICE ..:....... w * ( please • Pho , aa�c f ♦ •i. «rs Address: City, State Zip • r City License City License # a Cigggil6tid (Fully describe work to be performed - Attach I��l�� a ��t �p��i�01�iM�III�, P'IIIdIIII� y • e • .. is .. #. ,..... Sq Ft, A City of Wheat Ridge Faxed Roof Permit PERMIT - 20120463 PERMIT NO: 20120463 RECEIPT NO-CDAM7193 ISSUED: 04/24/2012 JOB ADDRESS: 3223 Fenton ST EXPIRES: 04/24/2013 JOB DESCRIPTION: REMOVE AND REPLACE 22 S OF ASPHALT SHINGLES and redeck *** CONTACTS *** Auth Code: 06118G OWNER (303)233-6436 GARDNER CARMEN B GC (303) 761-6400 J. Bretz 018118 Excel Roofing, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: SUBDIVISION CODE: 0470 SHAKLEE BLOCK/LOT#- 0 FEE SUMMARY ESTIMATED PROJECT VALUATION: 7,945.00 FEES Permit Fee 172.60 Permit fee additiona 93.3� Total Valuation 0.00 Use Tax 143.0 Use tax additional 54.0 ** TOTAL ** 462,96 *** COMMENTS *** CITY OF VREAT RIDGE 85/81/12 1:41 PH edba James E Bretz RECEIPT NO-CDAM7193 AMOUNT BASF RE3 AND REPLACE 2 147.35 20126463 Permit fee additiona 9&35 Use tax additional 54.08 PAYMENT RECEIVED AMOUNT vs 9162 147.35 Auth Code: 06118G TOTAL -------------------- 14735 Fa xed P ermi t PERMIT - 20120463 PERMIT NO: 20120463 ISSUED: ED: 04/24/2012 J OB ADDRESS 3223 Fenton ST EXPIRES 04/24/2013 JOB DESCRIPTION: N: REMOVE AND REPLACE 22 S S OF ASPHALT S II4TC; LEaS and z'€ deck I, h y , sl�taaature, do hereb attesf that the saoal to e p "'O""aed shalk coatrplyy °if t 1 ccc�n7p is � r a ° plan speeifications appiicaaleauildir codes, asad all applicable �nc�nit ipl codes, policies ar prtaedcires and tlraf 1 am e legal ovnes or Irae taeen authorized by the Ee al Duller cafth property and agar author z A to otatai this ermit and perftarrza t9ae r�orl� descritaed and a�apro�ed in ccan� action with this perarf. I further attest that I asrt le �= =ally a�rthc�ri�ed to include alr ntities narraed �� >�th►�� this dacn�nnt a arises fcr fhe �wror to be performed grad that all avcarl� to be perttsrzareds disclosed i this docurErent andior ifs" accoEapayin alaproved plans and specifications. f ClMf Building Official Late ST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY, U5/U / /ZUIO TUE 19-26 FAX 303 237 8929 303 Best Way 00011001 " •rte *,rr �r Phone, Via._ Mailing Addr (if different than property address) Address: City, Mate, dip; .. _. CCxirltY dtfat, _ ..� � .. Contractor License #° ` Ph r C w' #f 04/23/2012 15:36 303-761-6442 EXCEL ROOFING INC PAGE 02/02 VY/U TUB 14:76 PAX 311 237 8929 10a hest Way L4 Bldg Volu*jon- $_� 11011V M- 01/23/2012 MON 10:29 FAX DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 236-2856 CITY OF WHEAT RIDGE 7600 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Description : Building Permit Number: i. sic *. Sq� Ft. : Roof : stories: Residential Units' 2M �� City of Wheat Ridge Residential Fence PERMIT - 060136 PERMIT NO: JOB ADDRESS: DESCRIPTION, 060136 3223 FENTON ST 72" high cedar privacy fence. ISSUED: EXPIRES: 03/22/2006 09/22/2007 *** CONTACTS *** owner 303/780-3141 gc 303/433-7301 Carmen Gardner Ol~9544 Standard Lumber & Hardware Co. ** PARCEL INFO ZONE CODE, SUBDIVISION: .* R-1C UA USE, BLOCK/LOT#: R-3 0/ Permit Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED PROJECT VALUATION: FEES 46.43 ~~:H ~i1) 825.00 ** FEE SUMMARY ** Comments: KS: O P1case Nc:~." wner I contract' .' . or IS respon:;J~);,. ~:'.;r ' ,.. hnes and constructinv "Illpro" , ., , ' '"':'('T'crtv o ..L"ncr'~ ...... . approvedplanandrequiredd' , .c,,_." tOlhc The City is not responsible fi ~veloplJlcnt stalOdards. submitted within the plan o~ m~ccurate infOffilation CfTOrs resulting from i se an a?y construction naccurate mformation. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (l.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. fence cannot exceed 7211 in ht. date Signature of contractor/owner 1. This permit was issued in accordance with the provisions set forth In your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building Codes of wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All pla~ w i~~~O . d inspections. /' date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE. 303.234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 . (303-235-2855) APPLICATION Building Pemit Number: Date: Property Owner: C e..r~"'~l"dll\er . ..~ Property Address: "!> 1.-1..-3 f~ Sf:. (...\)\,..,.....+ Q,...L (. Phone: D()~-7'gl)~ 3/\{ ( \qS'I'Contractor License No.: ""- -)r=- 0. Z"OZ-IL- Company:C:;h~ ~ Co. 'il.~ J<4_~ Phone: ~1)i".J'B'!-r~ ( ~el'l'k.rb "8a~( OWNERlCONlRACmR SIGNATURE OF UNDERSTANDING AND AGREEMENT I Buildina Deaf. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Vv11eal Ridge Building C e (I.B.C) and all other applicable VVheat Ridge Ordinances, for work under this . Plans subject to field inspection. {OWN~~RI'SIGNED DATE't-lS'-ob (OWNER)(CONTRACTOR):PRINTED DATE ?5cS:..110 Value:$ '6ZS.~ PermitFee:$ ,..~.j(3 Plan Review Fee:$ Use Tad /y-;~ Total:$ C,I. .;L Use of Space (deScriPtiOn):'5"..C.J C4. InVAC-7 f~ ":h" tI.~h.. Description of work: \$. '(.n~'" ~ i.- ~~dsl l(.)c.'t :f..'i' ~~"tr (l) Ut'<)'--/r' f,"~S S-U......~ S"~ Sq. ft. added BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ONING COMMENTS: Approval: ~ , Zoning: ~,\v BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: IRE DEPARTMENT COMMENTS: Approval: Occunancv: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes ofVVheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (90) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review Is subject to field Inspections. Chief Building Official +.,.. DIVISION OF STANDARD LUMBER & HARDWARE CO. 4680 JASON STREET' DENVER, COLORADO 80211' PHONE: 303-433-7301 . FAX: 303-477-6326 Rec'd. in Ofe. Comp. Due NAME C....('IM~ Material elAvd: Style '(;c'I..()L'l' ?- '- fJg.. Work Order No. . Penni t App lied )-IS'-n6 Phon" "Sf')) - 78'5- 3/l{ ( {1;, 'g 0"2-1 Z- CORNER? N'D Qty. Open X Hgt. Type 0,.rJ1A.:f 'CVI..:tlY'- )"1. JOB ADDRESS ~ Z- -z... 3" Ft 50' Ft Ft Ft H 3 r....-l C-<..-JtleJ...( H "Z-lC'{)c'B' f,-,I HANDYMAN SPECIAL? INSTALLED? DIRECTIONS: {...[ I (.....1> ie......d (.D .-f'L, J...Je - . /I:. (2:r~ i 5' 55\{j- {~ ~ X ><- )<. ~ ,~. 7~1-Db i~ JJI- ") \ ~ 't ['/v " -4;f U..,...... ,t \, I ~, 1', , F" , i j i \ tl,"-^,- ~ H Collect S X >< ELECTRIC OUTLET? A,s+ ~~+ c....cJ h'v-,~"'- tAl 5+0 ~ )1;" )' 1 J c~.x ! ~ v1 . ~ l:l ""\ ! 6a<f/ /' ') ~- ~.-J 1 \\-. ,,/ \.0<,1/" \)/_~/./ F 1 ~ Ii r' ,'J' , ~~ ~\''''k!r >( ~ -:f ,,~~l>,! ><;: ~~ OtL).e...- , I ! I{ >( ~ )<. .7-~ .I - 5o)-'f7-2-15Z-$6 Salesman ~ Phone OEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number: Date: 13345 1/17/02 Property Owner: FLORENCE VERVECCHIO Property Address: 3223 FENTON ST Contractor License No. : 21170 Company: Bear Brothers Roofing Phone: 237-2851 Phone' 422-2725 Construction Value. Permit Fee' Plan Review Fee. Use Tax: $450.00 $23.50 $0.00 $6.75 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNE~JJ cr.,)!:Xl, b DATE \-("1-02- Total: $30.25 Use: Description: TEAR OFF & REROOF GARAGE W/ MODIFIED ROOFING ~ BUILDING DEPARTMENT USE ONLY - SIC Sq Ft Approval: Zoning: ~ Approval: ~" ,~J Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No . Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, prOVided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shalt be paid for a new permit No work of any manner shall be done that will change the natural flow of water causing a drainage problem Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shaH receive written approval on inspection card before proceediing with successive phases of the job. T s ~~rmit or the approval of drawings and specifications shall n.ot be construed to be a permit for, nor an approval of, any violation of the vis' n/ / I ~ding codes or any other ordinance, law, rule or regulation , (1) (2) (3) Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 .CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPLICATION Building Permit Number: Date: Property Owner;::f\ 0 (Le Il c..e \JElL V e cc.. ~: 0 Property Address: 32.. 2..3- te~n-Ctol 51.. w,'i2.. '\?;c.o:!> 3 Contractor License No.: 2. J 1"T 0 Company: -g~ ,,4- e><ta"" ~/Z..s "~.....\=; tV.., Phone: ?:.03_Z?7ZrS-1 Phone: 305- <n..2.-2.-1oz,l> OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pennit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and aU other applicable Wheat Ridge Ordinances, for work under this permit. (OWNER)(CONlRACTOR),SrGNED .1J ~ l2.i2 ...15..... DATE /-1) -0 oz, Description: --ru---L "/,,c cJ ~1Uo.f ~~~ tv)..M d D rI'':e:J tZo-o /c1Vj Construction Value:$ <y5:"l>-- Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: EXpiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. Ifchanges have been or ifsuspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow ofwater causing a drainage problem. (5) Contractor sliall notify the Building Inspectortwenty.four(24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specmcations shall not be construed to be a permit for, nor an approval of. any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. Chief Building Inspector