3035 Chase Street
i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office IfE TION NOTICE Inspection Type: - Job Address: Permit Number: a i ❑ No one available for inspection: Time f # /PM Re -Inspection required: Yes When corrections have been made,chedule four rg-ins gn online at: http✓/www.ci.wheatridge.co.uslinspec "on f M'MA- +rill i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE S ►cam -_ �--�- - /A�ft- Inspection Type: Job Address:-��`�'��^ Permit Number: _Zq�) `97)6 ❑ No one available for inspection: Time M/PM Re -Inspection required Yes `'o When corrections have been made, schedule for re -inspection online at: http://www.ci.wheatridge.co.uslinsp"on Dat d � Ins ect �" i CITY OF.WHEAT RIDGE Building Inspection Division ►/ (303) 235-2855 Office INSPECTION NOTICE S ICS` Inspection Type: Lld�� 1 Job Address: Permit Number: ❑ No one available for inspection: Time �) 2)'� wpm Re -Inspection required: Yes o When corrections have been made, sc le for re -inspersion online at: httpYlwww.ci.wheatridge.co.uslinspect on Date2 -2- Inspector 4" City of Wheat Ridge Residential Solar PERMIT - 201902468 PERMIT NO: 201902468 ISSUED: 11/27/2019 JOB ADDRESS: 3035 Chase St EXPIRES: 11/26/2020 JOB DESCRIPTION: Solar PV install, 4.88 kw, 16 panels, no structural required *** CONTACTS *** OWNER (303)725-4413 KOCH MARK C SUB (385)482-0045 LEE HATLEY 180271 BRS FIELD OPS, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 16_,713.76 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal o ner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. urther attest that I am legally authorized to include al i entities named within this document as parties to the work to be p rtormed nd that all work to be performed is disclosed in this doc en t and/or its' accompanying approved plans and specifications. 27 Signature of OWNER or CONTRACTOR (Circle one) Date I, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalppermit fee. 3. If this permit expires, a new permit may be required to be obtained.lssuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services 6. T issuance %�v rmit shall not be construed to be a permit for, or an approval of, any violation of any provision of any p cab a coe or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. -; I City of W heat lid e COMMUNITY DEVELOPMENT Building & Inspection Services 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits@ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # (� Plan Review Fee: Building Permit Application *`* Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3035 Chase Street Wheat Ridge, Colorado 80214 Property Owner (please print): Phone: Property Owner Email: Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: 3035 Chase Street Wheat Ridge , Colorado 80214 City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor Name: BRS Field Ops LLC City of Wheat Ridge License #: 180271 Phone: Contractor E-mail Address: permitting.department@blueravensolar.com For Plan Review Questions & Comments (please print): 385-482-0045 CONTACT NAME (please print): Linsey McClain Phone: 385-482-0045 CONTACT EMAIL(please print): permitting.department@blueravensolar.com Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # ❑COMMERCIAL FS -1 RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Residential Solar Rooftop PV System 4.88 kW 4.88 kW residential solar array Sq. FULF 280 BTUs n/a Gallons n/a 200 Amps Squares For Solar: 4.88 Kw 16 # of Panels n/a Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ $16,713.76 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the tnrthfidness of the information provided on the application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (C01VTR4CT0R) Signature (first and last name): <� e� %%GcC..fcu� For BRS Field Ops LLC DATE: 11/07/2019 Printed Name: Linsey McClain N ZONING COMMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: Domus jpjqo� q�g 4i (x T N F E R T N +t x T, is +C November 7, 2019 To: Blue Raven Solar 1403 North Research Way, Building J Orem, UT. 84097 Subject: Certification Letter Koch Residence 3035 Chase ST. Wheat Ridge, CO. 80214 To Whom It May Concern, Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, CO 80021 530-864-7055 Domusstructural@gmail.com 08:49:19 -0600' Ajobsite observation of the condition of the existing framing system was performed by an audit team of Blue Raven Solar as a request from Domus Structural Engineering. All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project, the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof. The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements. The observed roof framing is described below. If field conditions differ, contractor to notify engineer prior to starting construction. The roof structures of (MP1&2) consist of composition shingle on roof plywood that is supported by 2x6 rafters @ 24"o.c. with ceiling joists acting as rafter ties. The rafters have a max projected horizontal span of 8'-0", with a slope of 20 degrees. The rafters are connected at the ridge to a ridge board and are supported at the eave by a load bearing wall. The existing roof framing systems of (MP1&2) are judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The spacing of the solar standoffs should be kept at 72" o.c. for landscape and 48" o.c. for portrait orientation, with a staggered pattern to ensure proper distribution of loads. The scope of this report is strictly limited to an evaluation of the fastener attachment, underlying framing and supporting structure only. The attachment's to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading. All panels, racking and hardware shall be installed per manufacturer specifications and within specified design limitations. All waterproofing shall be provided by the manufacturer. Domus Structural Engineering assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Note: Seismic check is not required since Ss<.4g and Seismic Design Category (SDC) < B Design Criteria: • Applicable Codes = 2012 IBC/IRC, ASCE 7-10 • Roof Dead Load = 8 psf (MP1&2) • Roof Live Load = 20 psf • Wind Speed = 105 mph (Vult), Exposure C, Risk Category II • Roof Snow Load = 30 psf • Attachments: 1- 5/16" dia. lag screw with 2.5 inch min embedment depth, at spacing shown above. Please contact me with any further questions or concerns regarding this project. Sincerely, P" John Calvert, P.E. Project Engineer Koch Residence, Wheat Ridge, CO 1 Domu s' S'TR U C TV RAL Gravity Loading Roof Snow Load Calculations Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, CO 80021 530-864-7055 Domusstructural@gmail.com p9 = Ground Snow Load = 30 psf pf=0.7CeC,IPs Ce = Exposure Factor = 1 Cf = Thermal Factor = 1 1= Importance Factor = 1 pf = Flat Roof Snow Load = 30.0 psf P5 = CSPf Cs = Slope Factor = 1 ps = Sloped Roof Snow Load = 30.0 psf PV Dead Load = 3 psf (Per Blue Raven Solar) DL Adjusted to 20 Degree Slope 3.19 psf PV System Weight 2.00 Weight of PV System (Per Blue Raven Solar) 3.0 psf X Standoff Spacing = 4.00 ft Y Standoff Spacing = 5.50 ft Standoff Tributary Area = 22.00 sft Point Loads of Standoffs 66 Ib Note: PV standoffs are staggered to ensure proper distribution of loading Roof Live Load = 20 psf Note: Roof live load is removed in area's covered by PV array. Roof Dead Load (MPI&2) (ASCE7 - Eq 7-1) (ASCE7 - Table 7-2) (ASCE7 - Table 7-3) (ASCE7 - Eq 7-2) Composition Shingle 4.00 Roof Plywood 2.00 2x6 Rafters @ 24"o.c. 1.15 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.85 Total Roof DL (MP1 &2) 8.0 psf DL Adjusted to 20 Degree Slope 8.5 psf Koch Residence. Wheat Ridae. CO 2 l- o- n uS-'TRUCTtTRA1, Wind Calculations Per ASCE 7-10 Components and Cladding Input Variables Wind Speed 105 mph Exposure Category C Roof Shape Hip/Gable Roof Slope 20 degrees Mean Roof Height 20 ft Effective Wind Area 19.3 ft Design Wind Pressure Calculations Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, CO 80021 530-864-7055 Domusstructural@gmail.com Wind Pressure P = qh*G*Cn qh = 0.00256 * Kz * Kzt * Kd * V^2 (Eq. 30.3-1) Kz (Exposure Coefficient) = 0.9 (Table 30.3-1) Kzt (topographic factor) = 1 (Fig. 26.8-1) Kd (Wind Directionality Factor) = 0.85 (Table 26.6-1) V (Design Wind Speed) = 105 mph (Fig. 26.5-1A) Risk Category= II (Table 1.5-1) qh = 21.59 0.6*qh= 12.95 Standoff Uplift Calculations -Portrait Zone 1 Zone 2 Zone 3 Positive GCp = -0.84 -1.39 -2.23 0.38 (Fig. 30.4-1) Uplift Pressure = -10.86 psf -18.01 psf -28.86 psf 10.0 psf (Minimum) X Standoff Spacing = 4.00 4.00 2.67 Y Standoff Spacing = 5.50 2.75 2.75 Tributary Area = 22.00 11.00 7.33 Footing Uplift = -239 Ib -198 Ib -212 Ib Standoff Uplift Calculations -Landscape Zone 1 Zone 2 Zone 3 Positive GCp = -0.84 -1.39 -2.23 0.38 (Fig. 30.4-1) Uplift Pressure = -10.86 psf -18.01 psf -28.86 psf 10.0 psf (Minimum) X Standoff Spacing = 6.00 6.00 4.00 Y Standoff Spacing = 3.50 1.75 1.75 Tributary Area = 21.00 10.50 7.00 Footing Uplift = -228 Ib -189 Ib -202 Ib Standoff Uplift Check Maximum Design Uplift = -239 Ib Standoff Uplift Capacity = 450 Ib 450 Ib capacity > 239 Ib demand Therefore, OK Fastener Capacity Check Fastener = ? - 5/16" dia. lag Number of Fasteners = 1 Embedment Depth = 2.5 Pullout Capacity Per Inch = 250 Ib Fastener Capacity = 625 Ib w/ F.S. of 1.5 & DOL of 1.6= 667 Ib 667.2 Ib capacity > 239 Ib demand Therefore, OK Koch Residence. Wheat Ridae. CO 3 -D o,,,TtI S Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, CO 80021 530-864-7055 K N6 T F T R ING T. L t.; Domusstructural@gmail.com Framing Check (MPI &2) PASS w = 83 plf Dead Load 8.5 psf PV Load 3.2 psf Snow Load 30.0 psf 2x6 Rafters @ 24"o.c. Governing Load Combo = DL + SL Member Span = 8'- 0" Total Load 41.7 psf Member Properties Member Size S (in^3) I (in^4) Lumber Sp/Gr Member Spacing 2x6 7.56 20.80 DF#2 @ 24"o.c. Check Bending Stress Fb (psi) = fb x Cd x Cf x Cr (NDS Table 4.3. 1) 900 x 1.15 x 1.3 x 1.15 Allowed Bending Stress =1547.3 psi Maximum Moment = (wL^2) 18 = 667.2953 ft# = 8007.543 in# Actual Bending Stress = (Maximum Moment) / S =1058.9 psi Allowed > Actual -- 68.5% Stressed -- Therefore, OK Check Deflection Allowed Deflection (Total Load) = L/180 (E =1600000 psi Per NDS) = 0.533 in Deflection Criteria Based on = Continuous Span Actual Deflection (Total Load) _ (W -L'14) / (185*E*1) = 0.096 in = U1000 > U180 Therefore OK Allowed Deflection (Live Load) _ Actual Deflection (Live Load) _ L1240 0.4 in (w -L^4) / (185*E*1) 0.069 in U1392 > U240 Therefore OK Check Shear Member Area = 8.3 in^2 Allowed Shear = Fv * A = 1485 Ib Max Shear (V) = w * k / 2 = Allowed > Actual -- 22.5% Stressed -- Therefore, OK Koch Residence. Wheat Ridae. CO 4 GENERAL NOTES CODES AND STANDARDS 1, ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE (NEC), 2012 INTERNATIONAL RESIDENTIAL CODE (IRC), 2012 INTERNATIONAL BUILDING CODE (IBC), 2015 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES. 2 DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. 3 TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. SITE NOTES / OSHA REGULATION 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. 5 NO OF SHINGLE LAYERS -1 SOLAR CONTRACTOR 1 MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS 3 AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM. 7 EN PHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT AVAILABLE. 9 ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES.. DC COMBINERS, DC -TO -DC CONVERTERS.SOURCE CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (B) 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE EQUIPMENT LOCATIONS 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26] 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY [NEC 690.31 (A) -(B)] AND [NEC TABLE 310.15 (B)] 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT TO THE UTILITY AC DISCONNECT, OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 5 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. lo?"N APPROVED i I� Reviewed for Code Compliance slidKy of permit 7hr,•.svcnce of¢pe+rnitaapWowto/plaK%10t�►�"- ¢nd c¢mput¢tiuns ttiofl not tz o permit fp, or M OpDrowat of. o� NO:OttO� � any of the wevlsiom of the DuiUiny code or of * y Crty ordinonees. Pertnttf presuming to give ourhmity to vtolote of concet Me proWW" offt eidit cad, or ether orduronces of the tity sh*H not !t VOW. w V - r$t Street v zi "' IMllrllllr .�" . .a DESIGN CRITERIA ASCE 7 WIND SPEED: 105 MPH GROUND SNOW LOAD: 30 PSF EXPOSURE CATEGORY: C SEISMIC DESIGN CATEGORY: B SCOPE OF WORK SITE SPECIFICATIONS OCCUPANCY -R3 CONSTRUCTION - V -B ZONING: RESIDENTIAL INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM 4.88 kW DC PHOTOVOLTAIC SOLAR ARRAY ROOF TYPE: Comp Shingle MODULES: (16) Seraphim SEG-6MB-305BB INVERTER(S): Enphase IQ7-60-2-US,---- RACKING: Unirac SFM Infinity Approval Notes: Werify or provide supplemental ground rod or rods per 2017 NEC Art. 250.53(A)(2). 2) Natural Gas piping to be bonded s per 2017 NEC Art. 250.104(B). 3)Bond P/V panels to the building Grounding f **%W BLUE RAVEN SHEETINDEX PV1 - COVER SHEET PV2 - PROPERTY PLAN PV3 - SITE PLAN PV4 - EQUIPMENT & ATTACHMENT DETAIL PV5 - ELECTRICAL SINGLE LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS & ELECTRICAL NOTES PV7 - MAIN BREAKER DERATE CALCS. (IF NEEDED) PV8 - LABELS & LOCATIONS PV9 - CUSTOM DIRECTORY PLACARD (IF NEEDED - NEC 690.56(B)) 1403 N RESEARCH WAY, BUILDING J >' OREM, UT 84097 800-377-4480 Q- WWW.BLUERAVENSOLAR COM @ CONFIDENTIAL - THE INFORMATION 1tFa aHEREIN CONTAINED SHALL NOT BE .— ,t R USED FOR THE BENEFIT OF 00 ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT O BE DISCLOSED IN WHOLE OR IN Z PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT. WITHOUT THE I, WRITTEN PERMISSION OF h BLUERAVENSOLAR LLC. � NABCEP CERTIFIED - PV INSTALLATION PROFESSIONAL W Scott Gurney O # PV -011719-015866 ift CONTRACTOR: Z BRS FIELD OPS U 385.498.6700 SHEETINDEX PV1 - COVER SHEET PV2 - PROPERTY PLAN PV3 - SITE PLAN PV4 - EQUIPMENT & ATTACHMENT DETAIL PV5 - ELECTRICAL SINGLE LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS & ELECTRICAL NOTES PV7 - MAIN BREAKER DERATE CALCS. (IF NEEDED) PV8 - LABELS & LOCATIONS PV9 - CUSTOM DIRECTORY PLACARD (IF NEEDED - NEC 690.56(B)) DRAWING BY - DIN ENGINEERING DATE November 4, 2019 51111 PROJECT NUMBER 67429215 SHEET NAME COVER SHEET PAGE NUMBER REVISION PV1 0 CD Y CO 00 O 00 Z 2 O` N W U � c/) QY W O u0i (Q -a Z Mco U r oM 0 � U DRAWING BY - DIN ENGINEERING DATE November 4, 2019 51111 PROJECT NUMBER 67429215 SHEET NAME COVER SHEET PAGE NUMBER REVISION PV1 0 121'-2" N 9'-5„ 9'-511 L - I C El AC JB PV O ❑ w 2 MSP IB 51'-5"M ❑ ❑ O Z Of ❑ LL 0 I— 121 '-3" DC SYSTEM SIZE: 4.88 kW DC ROOF TYPE: Comp Shingle (16) Seraphim SEG-6MB-305BB Enphase IQ7-60-2-US,----INVERTER a� m tv U Lo co 0 co LEGEND INV INVERTER & DC DISCONNECT SUB (E) SUBPANEL LC (N) LOAD CENTER AC AC DISCONNECT 1:1 : UTILITY METER / SERVICE PANEL J8 JUNCTION BOX C❑ COMBINER BOX PV PV REVENUE METER ® FIRE SETBACK O EMT CONDUIT RUN (TO BE DETERMINED IN FIELD) PV WIRE STRING PROPERTY LINE *11�*4 BLUE l 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLARLLC. NACCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 SCAL8 16 E: 1/16" = V-0" 32 I BRS 85 IE 6 00 0% X DRAWING BY DIN ENGINEERING ber 4, 2019 PROJECT NUMBER 67429215 SHEET NAME PROPERTY PLAN PAGE NUMBER REVISION PV2 0 N > O Y co co O 00 Z O Q N o U N Q Z U Y N M W U) cap U - cIf W � w Q Lo >a) fn () () M DRAWING BY DIN ENGINEERING ber 4, 2019 PROJECT NUMBER 67429215 SHEET NAME PROPERTY PLAN PAGE NUMBER REVISION PV2 0 LEGEND INV INVERTER & DC DISCONNECT BLUE RAVEN SUB (E) SUBPANEL LC (N) LOAD CENTER 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 AC AC DISCONNECT 800-377-4480 WWW.BLUERAVENSOLAR.COM UTILITY METER / SERVICE PANEL CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED G T OF 14'-1 0" 14'-1 0" JB JUNCTION BOX ❑ ONE EXCEPT BLUERAVENSOLAR NOR SHALL IT M P2 BE DISCLOSED IN WHOLE OR IN # OF MODULES: 9 F COMBINER BOX PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, C �vq +� v v AZIMUTH:90° PV PV REVENUE METER O EXCEPT IN CONNEC TION SALE AND USE OF THE RESPECTIVE w� PITCH-.20' EQUIPMENT, WITHOUT THE A AC TSRF:76% FIRE SETBACK WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. MP1 3B AREA: 480.47 SQ. FT ® # OF MODULES: 7 AZIMUTH:2700 PV EMT RUN (TO EODETEIRM NED IN FIELD) NABCEP PITCH:20° OCERTIFIED TSRF:73% U 0 C) W pi PV WIRE STRING PV INSTALLATION AREA: 480.44 SQ. FT PROFESSIONAL MSP � B 32_4„ J = t i PROPERTY LINE Scott Gurney # PV -01 1 71 9-01 5866 OVERHEAD SERVICE LINE �` ❑`� �, ILL O M'^" SCALE: 1/8" = 1'-0" CONTRACTOR: 0 Z D 2 4 8 16 BRS FIELD OPS 0 385.498.6700 LL_ ❑ U CHIMNEY N CD �C CID c oO o co Sealed For O Existing Roof & o �- o N Attachment Only U cn p Y m M w Z M U - (A Lr) H_CL >(1) C:) 0 C) > � DRAWING BY DIN ENGINEERING •� •'•of 0%1 DATE Xt %g090 43019 v+ne° November 4, 2019 an «••••���•'•�� �%� CT NUMBER 67429215 DC SYSTEM SIZE: 4.88 kW DC ROOF TYPE: Comp Shingle Digitally signed by SHEET NAME John A. Calvert SITE PLAN (16) Seraphim SEG-6MB-305BB Date: 2019.11.07 11/7/19 PAGE NUMBER RENS' Enphase IQ7-60-2-US,----INVERTER 08:50:14 -06'00' PV3 0 0 PV ARRAY INFORMATION LL. II O 0 Z Q _ �o U) O H ih O M M U J_ (n Q w 0 V LL. LI_ O 0 Z Q U) n- 0 O h r Lu n J - � M O � v J_ (n Q H Lu 0 U PV MODULE COUNT: 16 MODULES # OF ATTACHMENT POINTS: 28 ARRAY AREA: Module Count x 17.51ft2 = 280.2ft2 ROOF AREA: 1046.6ft2 % OF ARRAY/ROOF: 26.8% ARRAY WEIGHT: Module Count x 50lbs = 800.Olbs DISTRIBUTED LOAD: Array Weight _ Array Area = 2.86 Ibs/ft2 POINT LOAD: Array Weight _ Attachments = 28.6lbs/attachment Infinity IMRAIL Seraphim SEG-6MB-305BB PV MODULE (E) ROOF MEMBRANE UNIRAC SLIDERS AND TRIMRAIL ROOF ATTACHMENTS FLASHING 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE Unirac SFM Infinity Seraphim SEG-6MB-305BB PV MODULE (E) ROOF MEMBRANE UNIRAC SLIDERS FLASHING 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE PV MODULE (BEHIND TRIM RAIL) Unirac SFM Infinity TRIM RAIL PORTRAIT LANDSCAPE ARRAY DETAIL, FRONT VIEW Scale: 3/8" = T-0" PORTRAIT LANDSCAPE ARRAY DETAIL, SIDE VIEW Scale: 3/8" = T-0" SFM Infinity Flashkit RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH Unirac SFM Infinity FRAME SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER. /H� WIDTH ROOF TYPE: Comp Shingle ROOF FRAMING TYPE: Rafter RAFTER OR TOP CHORD(TRUSS) 2x6 @ 24"0 C. CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x6 @ 24"O C. Sealed For Existing Roof & Attachment Only 11/7/19 BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 N DRAWING BY DIN ENGINEERING 0 I 0' he tR�9� November 4, 2019 n Vit, T1g OJECT NUMBER 67429215 SHEET NAME EQUIP. DETAIL PAGE NUMBER REVISION PV4 0 0 N O Y 00 00 O 00 z M O Q N o U N O LL Z Y a� M co O (nLu M U U) 2 U) LLJQ M OM ) i- U) w U) > i) DRAWING BY DIN ENGINEERING 0 I 0' he tR�9� November 4, 2019 n Vit, T1g OJECT NUMBER 67429215 SHEET NAME EQUIP. DETAIL PAGE NUMBER REVISION PV4 0 PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER (E) GROUNDING �L ELECTRODE (S) Approval Notes: 1)Verify or provide supplemental ground rod or rods per 2017 NEC Art. 250.53(A)(2). 2) Natural Gas piping to be bonded s per 2017 NEC Art. 250.104(B). 3)Bond P/V panels to the building Grounding Electrode System per 2017 NEC Art. 690(A). INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12]. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH ENPHASE COMBINER BOX WILL BE ACCESSIBLE TO UTILITY COMPANY 24/7 PV Production meter notes: 1. The self-contained metering will be in compliance with the most recent revision of the Xcel Energy Standard; specifically Section 4.11. 2. The PV production meter will be required to have the PV generation wired to the line side terminals (top of meter block). 3. The meter socket for the PV production meter shall be marked with a stamped brass, aluminum, or stainless steel tag, indicating the address including the unit, typically "PV PROD" in accordance with the requirements for "Meter Identification" in Section 4.14.4 of the Xcel Energy Standard. 4. The PV production meter shall be located within ten (10) feet of the existing utility meter. If there is any reason this cannot be accomplished, a site plan showing proposed equipment locations shall be submitted for review. The local meter shop must approve the site plan for application approval; site meetings can be arranged upon request. NOTE TO INSTALLER: The current Placard that we require at the utility meter and AC Disconnect is a yellow with black lettering (1) 10 AWGTHHN/THWN-2, CU., BLACK (L1) 16.0 AAC (2) 12 - 2 OF -B W/G, THHN/THWN-2, SOLID CU. MAX 9.0 A A (1) 12 - 2 OF -B W/G, THHN/THWN-2, SOLID CU. MAX 9.0 A A (1) 12-2TC-ER,THHN/THWN-2, CU. MAX 9.0 A AC 1 C J (1) 10 AWGTHHN/THWN-2, CU., RED (L2) 240 V AC 240 V A O 240 V A (1) 6 AWG BARE, CU (EGC) 240 V AC 00 00 (1) 10 AWGTHHN/THWN-2, CU., WHITE (N) O 00 Z O (1) 10 AWGTHHN/THWN-2, CU., GREEN (EGC) (1) 3/4 INCH EMT EXTERIOR o (1) 3/4 INCH EMT EXTERIOR INTERIOR EXTERIOR 13 L U E RAVEN U) QY 1. ALL CONDUIT TO BE RAN AT LEAST 7/8" ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. W Q) cOn (B 2. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN Z MLLJ U 1403 N RESEARCH WAY, BUILDING J PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. OREM, UT 64097 3. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ~ 1�CO >� U ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. U _..:.� 600-377-4480 WWW.BLUERAVENSOLAR.COM (16) Seraphim SEG-6MB-305BB CONFIDENTIAL - THE INFORMATION UL 1703 COMPLIANT HEREIN CONTAINED SHALL NOT BE 16 hase IQ7-60-2-US M ( ) En MICRO INVERTERS P USED FOR THE BENEFIT OF ANYONE EXCEPT UL 1741 COMPLIANT BLUERAVENSOLAR NOR SHALL IT 9 MODULES MAX FOR ALL SUB -BRANCH BE DISCLOSED IN WHOLE OR IN CIRCUIT(S) TO COMPLY WITH VRISE CALCS PART TO OSTHERS OUTSI Enphase IQ Combiner 3DE JUNCTION BOX ENT X-IQ-AM1-240-3 (OPTIONAL IF OF -B EXCEPT IN CONNEC TION WITH THE (SOLAR LOADS ONLY) CABLE USED FOR SALE AND USE OF THE RESPECTIVE ENTIRE HOMERUN) JUNCTION BOX EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF (E)200A MAIN SERVICE PANEL = _ _ (1) CIRCUIT BLUERAVENSOLAR LLC. (E)200A 2P MAIN BREAKER UTILITY PV (N)20A/2P A FrOF 9 MODULES PRODUCTION METER 200A PV AC DISCONNECT 3 l z (E)200A / 2P LEVER BYPASS NON-FUSED G _ G _ NAEC E P METER SOCKET LOCKABLE, VISIBLE OPEN 30A, 240V, 2 -POLE N CERTIFIED u (E)LOADS z PV INSTALLATION 2 JUNCTION BOX 1 PROFESSIONAL Scott Gurney I (1) CIRCUIT = _ # PV -011719-015866 (N)20A/2P (N)20A/2P OF 7 MODULES CONTRACTOR: L, u u=L1 L] 2 1 L2 G BRS FIELD OPS N EGC G �- C G G G 385.498.6700 120/240 VAC 60HZ 1 PHASE TO UTILITY 15 3 2 1 rRin G PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER (E) GROUNDING �L ELECTRODE (S) Approval Notes: 1)Verify or provide supplemental ground rod or rods per 2017 NEC Art. 250.53(A)(2). 2) Natural Gas piping to be bonded s per 2017 NEC Art. 250.104(B). 3)Bond P/V panels to the building Grounding Electrode System per 2017 NEC Art. 690(A). INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12]. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH ENPHASE COMBINER BOX WILL BE ACCESSIBLE TO UTILITY COMPANY 24/7 PV Production meter notes: 1. The self-contained metering will be in compliance with the most recent revision of the Xcel Energy Standard; specifically Section 4.11. 2. The PV production meter will be required to have the PV generation wired to the line side terminals (top of meter block). 3. The meter socket for the PV production meter shall be marked with a stamped brass, aluminum, or stainless steel tag, indicating the address including the unit, typically "PV PROD" in accordance with the requirements for "Meter Identification" in Section 4.14.4 of the Xcel Energy Standard. 4. The PV production meter shall be located within ten (10) feet of the existing utility meter. If there is any reason this cannot be accomplished, a site plan showing proposed equipment locations shall be submitted for review. The local meter shop must approve the site plan for application approval; site meetings can be arranged upon request. NOTE TO INSTALLER: The current Placard that we require at the utility meter and AC Disconnect is a yellow with black lettering ga lal It 4, 2019 PROJECT NUMBER 67429215 SHEET NAME ELEC. 3 LINE DIAL. PAGE NUMBER REVISION F 1 0 U N O ,C 00 00 O 00 Z O N o W oC/)U U) QY W Q) cOn (B Z MLLJ U CO ~ 1�CO >� U U _..:.� ga lal It 4, 2019 PROJECT NUMBER 67429215 SHEET NAME ELEC. 3 LINE DIAL. PAGE NUMBER REVISION F 1 0 IVIV VVLL JI L1.1111.l111VIVJ JC RATED POWER (STC) MODULE VOC MODULE VMP MODULE IMP MODULE ISC VOC CORRECTION VMP CORRECTION SERIES FUSE RATING DJ. MODULE VOC @ ASHRAE LOW TEMP D1. MODULE VMP @ ASHRAE 2% AVG. HIGH TEMP MILKUINVtKILKSPLLII-ILAIIUNJ Enphase IQ7-60-2-US POWER POINTTRACKING (MPPT) MIN/MAX 22 - 48 V DC MAXIMUM INPUTVOLTAGE 48 V DC MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC MAXIMUM USABLE DC INPUT POWER 350 W MAXIMUM OUTPUT CURRENT 1 AAC AC OVERCURRENT PROTECTION 20 A MAXIMUM OUTPUT POWER 240 W CEC WEIGHTED EFFICIENCY 97% AL. t HUIUVULAIILIVIUUULtIVV\KKIIVIj(NtLb`JU.SZ) NOMINAL OPERATING AC VOLTAGE 240 V AC NOMINAL OPERATING AC FREQUENCY 47- 68 HZ AC MAXIMUM AC POWER 240 VA AC MAXIMUM AC CURRENT 1.0 A AC MAXIMUM OCPD RATI NG FOR AC MODULE 20 A AC DESIGN LOCATION AND TEMPERATURES TEMPERATURE DATA SOURCE ASHRAE 2% AVG. HIGH TEMP STATE Colorado CITY Wheat Ridge WEATHER STATION SALISBURY WICOMICO CO AP ASHRAE EXTREME LOW TEMP (°C) -14 ASHRAE 2% AVG. HIGH TEMP (°C) 33 SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR F NUMBER OF MODULES PER MPPT DC POWER RATING PER CIRCUIT (STC) TOTAL MODULE NUMBER STC RATING OF ARRAY AC CURRENT @ MAX POWER POINT (IMP) MAX. CURRENT (IMP X 1.25) OCPD CURRENT RATING PER CIRCUIT MAX. COMB. ARRAYAC CURRENT (IMP) MAX. ARRAY AC POWER 9 2745 7 2135 VRISE(V) VEND(V; %VRISE IQ7-9 VRISE SEC. 1(MICRO TO JBOX) 32.4 16 MODULES 4880W DC 9.0 11.25 20 7.0 8.75 20 VRISE SEC. 2 ()BOX TO COMBINER BOX) 30 12 Cu. 1.09 16.0 384OW AC AC VOLTAGE RISE CALCULATIONS DIST (FT) COND. VRISE(V) VEND(V; %VRISE IQ7-9 VRISE SEC. 1(MICRO TO JBOX) 32.4 12 Cu. 1.18 241.18 0.49% VRISE SEC. 2 ()BOX TO COMBINER BOX) 30 12 Cu. 1.09 241.09 0.45% VRISE SEC. 3 (COMBIN ER BOX TO POI) 10 10 Cu. 0.41 240.41 0.17% TOTALVRISE JUNCTION BOX TO MAX. SHORTCIRCUITCURRRENT (ISC) = 2.68 242.68 1.11% PHOTOVOLTAIC AC DISCON NECT OUTPUT LABEL (NEC 690.54) AC OUTPUT CURRENT 16.0 A AC NOMINAL AC VOLTAGE 240 V AC GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690-471 AND [NEC 250-501 THROUGH [NEC 250-60] SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64C.]. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.1221, AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED. 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO [NEC 690.45] AND BEA MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE (#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF #4 AWG OR LARGER) 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.661, DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM #8AWG WHEN INSULATED, #6AWG WHEN EXPOSED TO DAMAGE. 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR) 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 4. UV RESISTANT CABLE TIES(NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A -B). 300.4 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE -2. AND SINGLE -CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC -ER, OR EQUIVALENT, ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC CONDUCTOR SIZE CALCULATIONS MICROINVERTERTO MAX. SHORT CIRCUIT CURRRENT (ISC) = 9.0 AAC JUNCTION BOX (1) MAX. CURRENT (ISC X1.25) = 11.3 AAC CONDUCTOR (TC -ER, COPPER (90°C)) = 12 AWG CONDUCTOR RATING = 30 A AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 28.8 > 11.3 JUNCTION BOX TO MAX. SHORTCIRCUITCURRRENT (ISC) = 9.0 A AC JUNCTION BOX (2) MAX. CURRENT (ISC X1.25) = 11.3 AAC CONDUCTOR (UF -B, COPPER (60°C)) = 12 AWG CONDUCTOR RATING = 20 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 19.2 > 11.3 JUNCTION BOX TO MAX. SHORT CIRCUIT CURRRENT (ISC) = 9.0 AAC COMBINER BOX (3) MAX. CURRENT (ISC X1.25) = 11.3 A AC CONDUCTOR (UF -B, COPPER (60°C)) = 12 AWG CONDUCTOR RATING = 20 A CONDUIT FILL DERATE = 0.8 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 15.36 > 11.3 COMBINER BOX TO INVERTER RATED AMPS = 16.0 A AC MAIN PV OCPD (15) MAX. CURRENT (RATED AMPS X1.25) = 20 A AC CONDUCTOR (THWN-2, COPPER (75°C TERM.)) = 10 AWG CONDUCTOR RATING = 35 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.96 ADJUSTED AMP. = 33.6 > 20.0 690.81 FOR MULTIPLE CONDUCTORS 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8" ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (13)(2)(a), NEC TABLE 310.15(13)(3)(a).& NEC 310.15(13)(3)(c)]. 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE -2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V. UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90-C RATED, WET AND UV RESISTANT, RATED FOR 600V 11. 4 -WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY * USE -2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE ** USE -2 IS AVAILABLE AS UV WHITE 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH NEC 230.6(4) AND SECURED NO GREATER THAN 6' APART PER NEC 330.30(B). BLUE RAVEN 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW.BLUERAVENSOLAR COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLARLLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 U O Y W .E m 4] U) N N J� W m L U M CD M U >0 Y 00 00 W N 2 W I- W W U 0 DRAWING BY O\ DI INEERING 69e DATE Nov mb19 •�\d�rc3 PR JECT N `_ 67429215 SHEET NAME ELEC. CALCS. PAGE NUMBER REVISION PV6 0 Lit-, �! = TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED — IN THE OPEN POSITION IF - DIRECT � PHOTOVOLTAIC MAXIMUM VOLTAGE VDC MAX CIRCUIT CURRENT AMPS PACUT CURRENT A NO�IINALOPERATINGACVOLTAGE V I DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM ZLWARWM INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL 1 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B), NEC 705.221 LABEL2 AT EACH DC DISCONNECTING MEANS, INCLUDING THE DC DISCONNECT AT THE INVERTER. [NEC 690.53, NEC 690.13(B)] LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABEL 4 AT POINT OF INTERCONNECTION FOR EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FORM MULTIPLE SOURCES, EACH SERVICE EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION SOURCE LOCATIONS. [NEC 705.12(8)(3)] LABEL 5 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(13)(2)(3)(b)] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWTCH TO THE 'OFP POSITION TO WARS:w SHUT DOWN PV SYSTEM ¢4 AND REDUCE SHOCK HAZARD _ IN THE ARRAY LABEL 7 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS, SPACED AT MAXIMUM 1OFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 8 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] 'I N'NG LABEL 15 PERMANENT DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT LOCATION IF ALL A1AIN DISTfasUT10NUTIUTYDISCONNECT(B) ELECTRICAL POWER SOURCE DISCONNECTING POWER TO T"BUILDING IS ALSO SUPPLIED MEANS (SOLAR ARRAY RAPID SHUTDOWN FROM A ROOF MOUNTED SOLAR ARRAY WITH A RAPID SHUTDOWN DISCONNECTING MEANS SWITCH) ARE GROUPED AND IN LINE OF SITE OF GROUPED AND LABELED WITHIN LINE OF SITE MAIN SERVICE DISCONNECTING MEANS. AND 10 FT OF THIS LOCATION. [NEC 690.56(C) &NEC 705.10]. BVI I � + LABEL 9 POWER TO THIS BUILDING IS ALSO rCCNW'CT0RS FOR PV SYSTEMS THAT ONLY SHUTDOWNSUPPLIED FROM MAIN DISTRIBUTIONCONDUCTORS LEAVING THE ARRAY: UTILITY DISCONNECT LOCATEDHUTDOWNSWITCti SIGN TO BE LOCATED ON OR NO MORE THAN 3OFF.PosmarFT AWAY FROM SERVICE DISCONNECTING wrCONDUCTORS ,-----MEANS TO WHICH THE PV SYSTEMS ARE THEARRAY CONNECTED AND SHALL INDICATE THE V1MIN LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN THE ARRAY REMNN ENERGIZED IN %IT SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(B)] LABEL 11 POWER TO THIS BUILDING IS ALSO SUPPLIED SIGN LOCATED AT AC COMBINER BOX FOR FROM ROOF MOUNTEDSOLARARRAY.SOLAR ALL M I C RO-I N V E RTE R/ AC MODULE ARRAY RAPID SHUTDOWN DISCONNECT IS RAPID SHUTDOWN TEST INSTALLS (IF APPLICABLE). LocATEDOUTSIDENExrroLmLmMErER. NOT REQUIRED LABELING DIAGRAM FOR MICRO INV.: MAIN SERVICE PANEL LABEL 16 PERMANENT DIRECTORY TO BE LOCATED AT SOLAR ARRAY RAPID SHUTDOWN SWITCH DENOTING THE LOCATION OF THE SERVICE EQUIPMENT LOCATION IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10] LABEL 17 PERMANENT DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION OF THE PV RAPID SHUTDOWN SYSTEM DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [NEC 705.10, NEC 690.56(C)(1)] Nor - BLUE 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW. BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 B 385.498.6700 EXISTING SUB PANEL PV COMBINER LABEL 6 O O (IF WHERE POINT OF SUBPANEL- ARNING ( O O NTERCONNECTION AC DISCONNECT IF USED TO COMBINE AC JUNCTION BOX AWONLY IF 3 OR MORE SUPPLY SOURCES TO 12 13 A BUSBAR) IS MADE) (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS OR AC COMBINER BOX SIGN LOCATED AT LOAD CENTER IF IT (� THIS EQUIPMENT FED MULTIPLE CONTAINS 3 OR MORE POWER SOURCES. O OO O O O SOURCES. TOTAL RATING OF ALL [NEC 705.12(13)(2)(3)(C)] O O OVERCURRENT DEVICES, EXCLUDING ° ° ° IF BREAKER USED 13 10 O O MAIN SUPPLY OVERCURRENT 00 00 DEVICE, SHALL NOT EXCEED R PLACARD O & O4 16 OO OO AMPACITY OF BUSBAR.J. O IF BREAKER USE Z 0 ,o (ONLY IF PV ° O _0 L O I LABEL 10 INTERCONNECTIO F— O O N SIGN LOCATED AT RAPID SHUT DOWN CONSISTS OF LOA 11 Q (� DISCONNECT SWITCH [NEC 690.56(C)(3)]. SIDE BREAKER) Uco C) SWITCH tFoFOf Y a) 0 Uj LABELING DIAGRAM FOR STRING INV. ! DC OPTIMIZER INV.: Q �_ M CO MAIN SERVICE PANEL Z E � C%) PLACARD TO BE PLACED AT THE MAIN EXISTING SUB PANEL PV COMBINER INVERTER (S) — U i' PHOTOVOLTAIC O 13 u1 Q L v to BILLING METER PER XCEL ENERGY. (IF WHERE POINT OF SUBPANEL - SYSTEM CONNECTED INTERCONNECTION AC DISCONNECT IF USED TO COMBINE ~ 0O 0 12 M IS MADE) (IF REQ. / INSTALLED) PV OUTPUT CIRCUITS (/) U) O3 & O4 LABEL 13 ° ° IF BREAKER USED O O O O DRAWING BY PLACARD TO BE PLACED AT AC ^ dANtNGINEERING PV AC DISCONNECT DISCONNECT PER XCEL ENERGY. ° D ° OR9 O &O4 16 13 O 15 OR 17 IF BREAKER USED 2 II JUNCTION BOX DA1 9 CARD OR PLA°� 3 Dc at R UO OR COMBINER BOXrD /November 4, 2019 5 IQ n -vision ONLY IF PV LABELING NOTES: ( (ONLY IF PV 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO INTERCONNECTIO INTERCONNECTION O 10 1O 7 PR CT NUMBER DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND CONSISTS OF LOA CONSISTS OF LOA 11 �� O O7 67429215 MAKE APPROPRIATE ADJUSTMENTS. SIDE BREAKER) SIDE BREAKER) 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. INTEGRATED DC DISCONNECT SHEET NAME 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. LABELS 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 'ELECTRICAL DIAGRAMS SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS 110.211 PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, REPRESENTATION OF PROPOSED SCOPE OF WORK. PAGE NUMBER REVISION AND PERMANENTLY AFFIXED [IFC 605.11.1.11 PV8 Eripha.se Aicroinverterw Esta I rr ray ,. 00 To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro— and Enphase IQ ?+ Micro - dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase its System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy-, Enphase IQ Battery—, and the Eriphase Enlighten- monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry! -leading warranty of up to 25 years - Easy to Install Lightweqght and simple Faster installation with improved, fighter two -wire cabling Built-in rapid shutdown on -pliant (NEC 2014 & 2017 Optirreze•d for high powered 60-ceil and 72-cefl* modules More than a million houfs of testing Class II double -insulated erclQsatee UL listed Complies with advanced grid suppom voltage and frequency fide -through requirements Remotely updates to resp€ nd to changing grid requirements Configurable for varying grid profiles Meets C.A lRule 21 (UL 1741 -SAJ Th& IQ 7+ Micros required to suppor 72 -call mo, wt iZs E�� '11%W :. RAVEN 1403 N RESEARCH WAY, BUILDING J Enphase IQ 7 and IQ 7+ Microinverters OREM,UT84097 800-377-4480 INPUT DATA (DC) I07 -60 -2 -US / I07 -60 -B -US IQ7PLUS-72-2-US t IQ7PLUS-72-8-US — - WWW.BLUERAVENSOLAR.COM Commonly used module pairings' 235 W- 350 W + 235W -440W+ CONFIDENTIAL - THE INFORMATION Module compatibility 60 -cell PV modules only 60 -cell and 72 -cell PV modules Maximum input DC voltage 48 V 60V HEREIN CONTAINED SHALL NOT BE Peak ower tracking voltage P g g 27 V -37 V 27 V - 45 V USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN Operating range 16 V- 48 V 16V -60V SOLAR NOR SHALL IT BE Min/Max start voltage 22V 48 V 22 V1 60 V DISCLOSED IN WHOLE OR IN PART Max DC short circuit current (module Isc) 15A 15A TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN Overvoitage class DC port 11 it CONNECTION WITH THE SALE AND DC port backfeed current 0 A 0 A USE OF THE RESPECTIVE PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; EQUIPMENT, WITHOUT THE AC side protection requires max 20A per branch circuit WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA h g� E P A Nominal (L -L) voltage/range' 240 V / 208V/ 240V/ 248 V 1 CERTIFIED 11-264 V 183-229V 11-264 V ? 1.21 Maximum continuous output current 8 0 A 240 V) 1.15 A (208 V) A 240 V) 13 9 A (208 V) PV INSTALLATION Nominal frequency 60 Hz 60 Hz Extended frequency range 47 -68 Hz 47- 68 Hz PROFESSIONAL AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Scott Gurney Maximum units per 20 A (L -L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) u PV -011719-015866 CONTRACTOR: Overvoltage class AC port III III 4C port backfeed current 0 A 0 A BRS FIELD OPS Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading _. 0.7 lagging 0.7 leading ... 0.7 lagging 385.498.6700 EFFICIENCY @240 V @208 V X5240 V @208 V Peak CEC efficiency 97.6 %, 976 °,� 97.5% - 973 CEC weighted efficiency 9T0 97.0,:, 97.0',--� 97.0 MECHANICAL DATA _Ambient temperature range ._.... .._ _ v -40°C to +65°C Relative humidity range 4°,, to 100"" (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q -DCC -5 adapter) Connector type(lQ7-60-MS&IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateabie). Adaptors for modules with MC4 or UTX connectors: PV2 to MCA: order ECA -S20 -S22 PV2 to UTX: order ECA -S20 -S25 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection- No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environmental category 1 UV exposure rating NEM A Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741 -SA) City of UL 62109-1, UL1741IIEEE1547, FCC Part 15 Class B, ICES -0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 Ridge This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions, Aat pivisi n 1. No enforced i)C!AC ratio, Sec, the compatbiloy calculalor ai hIlLw'tenohase eom/en-us/sup us/supporl/m diile cor-ipatib fvly. 2. Nominal voltage range can be extended beyond nom nal if reqs -red bylhc nfYty. 3. Lir*tits mayvaiy. Refer to local requaernentslo define the number of m`croinvertem per branch rn your area. SHEET NAME To learn more about Enphase offerings, visit enphase.com EN PHAS E. SPEC SHEET _ , ., 3 �, i F i l; . Sci lE.i. t .t;i„r .� kS ... 4. ,i .. ..x .,.'.Jy ,✓{;( , .:"ijY i ,� PAGE NUMBER REVISION SS � Enphase Networking IQ Combiner 3 (X-1Q-AM1-240-3) u� LISTED To learn more about Enphase offerings, visit enphase.com The Enphase 10 Combiner 3" w'th Enphase IQ Envoy "' const dates riterconnection equ'ipment I nto a singe enclosure and stream 'nes PV and storeae ;nsta at ons by prow d ng a consistent, pre-w.red soiut on for res 'dent.2 app `cations. It o'ers up to four 2 -pole 'input c7rcu is and Eaton BR, ser es busbar 23sernb'N, Smart Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Simple Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2 -pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Reliable Durable NRTIL-certified NEMAtype 3R enclosure Five-year warranty UL listed **%W BLUE RAVEN Enphase IQ Combiner 3 1403 N RESEARCH WAY, BUILDING J MODEL NUMBER OREM, UT 84097 _IQ Combiner 3 X -IQ -AM 1-240-3 IQ Combiner 3 with Enphase IQ Envoi printed circuit board for integrated revenue grade PV 800-377-4480 production metering (ANSI C12-20 +/- 0.5-A) and optional* consumption monitoring (+/-2.5'x). WWW.BLUERAVENSOLAR.COM ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect' CONFIDENTIAL - THE INFORMATION CELLMODEM-03 (4G / 12 -year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 HEREIN CONTAINED SHALL NOT BE OF CELLMODEM-01 (3G / 5 -year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, USED FOR THE BENEFIT ANYONE EXCEPT BLUE RAVEN CELLMODEM-Ml (4G based LTE -M / 5 -year data plan) wherethere is adequate cellular service in the installation area.) SOLAR NOR SHALL IT BE Consumption Monitoring* CT DISCLOSED IN WHOLE OR IN PART CT -200 -SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5',,), TO OTHERS OUTSIDE RECIPIENTS Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. ORGANIZATION, EXCEPT IN BRK-10A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 CONNECTION WITH THE SALE AND BRK-15A-2-240 Circuit breaker, 2 pole, 15A, Eaton BR215 USE OF THE RESPECTIVE BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE EPLC-01 Power line carrier (communication bridge pair), quantity 2 RAVEN SOLAR LLC. XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for FPLC -01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty �CERTIFIED System voltage 120/240 VAC, 60 Hz PV INSTALLATION Eaton BR series busbar rating 125 A PROFESSIONAL Scott Gurney Max. continuous current rating (output to grid) 65 A # PV -01 1719-015866 Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2 -pole Eaton BR series Distributed Generation (DG) breakers only (not included) CONTRACTOR: Max. continuous current rating (input from Pi 64A BRS FIELD OPS 385.498.6700 Max. total branch circuit breaker rating (input) BOA of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 375 x 16.8 cm (19.5x 14.75' x 6.63'). Height is 21.06'(53.5 crin with mounting brackets), Weight T5 kg (16.5 lbs) Ambient temperature range -400 C to +460 C (400 to 1150 F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NIRTIL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20 Ato 50 A breaker inputs: 14 to 4AWG copper conductors 60 A breaker branch input: 4 t 1/0 AWG copper conductors Main lug combined output: 10 to 2/O AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS integrated 1,vi-Fi 802.11b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-Ml (4G based LTE -M) city of (not included) COMPLIANCE Whey Ridge Compliance, Combiner UL 1741 CAN/ CSA C22.2 No, 107.1 47 CFR, Part 15, Class B, ICES 003 9 Division Production metering: ANSI C12.20 accuracy class 0.5 (PVproduction) Compliance, IQ Envoy UL 60601-1iCANCSA 22.2 No. 61010-1 " Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings, visit enphase.com -,as(, Eej,- 4ii,qc, -ts ,-e -, ieir E.,,_,ecrve c.A,,,e,,. ENPHASE. SHEET NAME SPEC SHEET PAGE NUMBER REVISION C 1 0 Safety Resistance to salt mist corrosion at your request Anti -PID products using advanced module technology Performance High efficiency and enhanced module di,ability �r- Resistance to ammotna Corrosion d your request World 1 st com pang to pass `Thresher Test' and 'On-site Power Measurement Validation' certificate ;o- Outstandi no po— output capability at ioa ;rradiance Marx ?:. 'tayye 6 �sazas #'r tame r. p srn 34Wy ss a:M �'ha! Guarantee on product 10material and workm anship Product is certified by UL1703 9 s Bankable products Withstand up to 2400Pa wind and 54001pa snow Ioad%IE C). long lasting SERAPHIM ENERGY GROUP MANAGEMENT SYSTEM ISO 9001: Quality management system ISO 14001: Standard for environmental management system OHSAS 18001: Intemational standard for occupational health and safety assessment system lire �ai'. �L�QCc c us t s s 25 Linear power otteptd warranty YEARS Spe neatens are subject to charge mthout notification SEG-I)S I N -2019V 1 J �, Copyright 2019 Seraphm eE' atAr_K BACk-6tiEE7 f BIkCK KRASv7E PRQ`JkJGTS Electrical Characteristics(STC) Maximum Power at STC -P NV) 295 300 - 305 310 Open Circuit Voltage N. v) 39.5 39.7 39.9 40.2 Soon Cvcult Current -0y tA) 9.56 9.65 9.76 982 Maximum Pow_ Vclage-V,(V, 31.9 321 32.3 326 Maximum Power Cunent- II_iA) 925 9.35 9.45 951 Module Efficiency STC -n, ilk) 18.13 1844 1875 19.05 Power Tolerance 'W! 1 t0.+4.99) 40 GP Maximum System Volage (V) 1000 or 1SWUL; - Mammum Series Fuse Rating IA) 20 Fire Pedormarrx Type2 or Typel{UL) Electrical Characteristics(NOCT) Maximum Poem at NOCT-P„,,{W) 219 223 226 230 Open Circuit Voltage-y-ivi 36.5 367 36.3 371 Short Circuit Cunem -!Y (A) 7.73 7.82 7.91 7% Maximum Power Voltage -v_ iv) 301 30.3 30-4 30.7 Mrannium Poem Current 4,(A) 7.28 736 7.44 7.50 Temperature Characteristics Pmax Temperature Coefficient Vac Temperature Cc eflloent iso Temperature Coefficient Operating T_np_ature Nomnal Operating Ceti Temperature +NOCTl, Packing Configuration Contain_ Pieces per Pallet - Pallets per Contain_ Pieces per Curttaner Mechanical Specifications 20GP 3C 12 360 1600 i 492. a5 -6i,57.34 57.34 05x1 33 �n�, nTkg! 3s56s; M—ysali a msr.eac=s_i 3.2 mm AR —.g i—p— 91,,- tw,'xm Anod—d sb—ilt. etby IP67 12AWC..c -guy :10i h1C4 Compal,d� STC. Irradiance 1000 W/m', modi#e temperature 25-C. AM=1.5 NOCT to adiance 8W W/m'. ambient temperature 20"C. "no speed tm1s Speaficabons are subject to change without further notification. 51 Z1 Sec4on A -A 141 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WWW BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP E`CCERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 -0 389W'C 4 28 %F C ' All Dimensions m mm The above dra—g 5 a graphical representation of the product. *0 06 ;W'C -40- 85'C I-V Curve 4512 'C._,—^--*- - i p;Y, Vutm' 40 GP 30 28 84101 e 1 City of = i Ridge °fl Di ion xi 4� 1 B ldin9 Specifications are subject to change vathout notification SEG -DS -EN -201 e/1 1 f Copyi ght 2019 Seraphim SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS Basic Features • Stamped Seamless Construction • 18 Gauge Galvanized Steel Powder Coated Surfaces • Flashes into the roof deck • 3 Roof deck knockouts .5", .75", 1" • 5 Centering dimples for entry/exit fittings or conduit • 2 Position Ground lug installed • Mounting Hardware Included —Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP 110C for fuse holders, 600V 50 AMP 90C for rail mounted terminal blocks and 600 V 175 AMP 90C for Power Distribution Blocks. Use Copper Wire Conductors. SolaDeck Model SD 0783 SolaDeck UL50 Type 3R Enclosures Available Models: Model SD 0783 - (3" fixed Din Rail) Model SD 0786 - (6" slotted Din Rail) SolaDeck UL 1741 Combiner/Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated - 60OVDC, 120AMPS Model SD 0783-41 3" Fixed Din Rail fastened using Norlock System **Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP 1- Power Distribution Block 60OVDC 175AMP 1- Bus Bar with UL lug Model SD 0786-41 6" Slotted Din Rail fastened using steel studs **Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug conduit or fittings, base is center dimpled for fitting locations. Model SD 0783-41, wired with Model SD 0786-41, wired with Din Rail mounted fuse holders, Din Rail mounted fuse holders, bus bar and power distribution terminal blocks and bus bars. block. RSTC Enterprises, Inc • 2219 Heimstead Road . Eau Cliare, Wl 54703 For product information call 1(866) 367-7782 M-.., 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 WW W.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP C_ ERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NUMBERI REVISION SS moll S I P L" wool 1 14 ON , SFM'1I,,1.',1CR0RA1L" TER 1`1 NAL TORQUE, Install Conductor and torque to the followir 4-6 AWG: 3 5in-tbs 5 AWG -. 25 in Abs 10-14 AVG: .20 in -lbs TERMIINALTORQUE ' " instatt Conductor and . or � quetothe foLlowing: 4-14 AWG: 3 5i n -lbs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WEESLUG Single Use onty TERMINAL TORQUE, 1 nstAl Conductor and torque to the fottowing: 6 -14 AWG I 7ft-lbs LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUC, DETAIL & TO FF INTO Rsco Lay -In Lug (GBL4DBT) ILsco Flange Lug(SGB-4) WiLeyWEEBLug (6.7) • 10-32 mounting hardware 9 1/4" mounting hardware 0 1/4" mounting hardware • Torque = 5 ft -Lb 0 Torque= 75 in -Lb 0 Torque = 10 ft4b • AWG 4-14 -Solid or Stranded 0 AWG 4-14 -Solid or Stranded 0 AWG 6 -14 -Solid orStranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACTTO PREVENT CORROSION a ground lug to any moduLe at a Location on the modute specified by the moduLe manufacturer. E -W BONDING PATH: E -W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicroraiLTM and splice. N -S BONDING PATH: N -S module to module bonding is acco m ph s hed with bonding clamp with 2 i nteg ra I bonding pins. iJefei'ciw$C) Z'U aLtel'lliate At'ern- t�npthod TRIMRAIL BONDING PATH: TrimraiL to module bonding is accomplished with bonding cLampwith integral bonding pin and bonding T -bolt. ; mi 1403 N RESEARCH WAY BUILDING J OREM, LIT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR INPART TO OTHERS OUTSIDE REC PI ENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED] PV INSTALLATION PROFESSIONAL Scoff Gumey # PV -011719-015866 CONTRACTOR: BIRS FIELD OPS 385.498.6700 SHEET NAME SPEC SHEET PAGE NUMBER REVISION S 0 tintertek AUTHORIZATION TO MARK Total Quality. Assured. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: Cixi Emeka Aluminum Co. Ltd 1411 Broadway Blvd NE Product: No. 688 ChaoSheng Road Address: Albuquerque, NM 87102 Address: Cixi City Zhejiang Province 315311 Country: USA Country: China Klaus Nicolaedis Jia Liu Contact: Tom Young Contact: Robin Luo 505-462-2190 +86-15267030962 Phone: 505-843-1418 Phone: +86-13621785753 FAX: NA FAX: NA klaus.nicolaedis@unirac.com jia.liu@cxymj.com Email: toddg@unirac.com Email: buwan.luo@cxymj.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA U.S.A. Control Number: 5003705 Authorized by: 11 for Dean Davidson, Certificati ranagen CTUS S Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is tot the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. InterteKs responsibility and liability are limited to the tens and conations of the agreement. Intertek assumes no Iia lity to any party, Other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authonzallon to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entlrety. Use of intenek's Ceafication mark is restricted to the conations laid out in the agreement and in this Authonzation to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material. product or service must first be approved in tinting by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 ATM for Report 102393982LAX-002 Page Iof1 ATM Issued: 9 -Apr -2019 ED 113.3.15 (24 -Apr -17) Mandatory **%W !LUE 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 W WW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 ow of ,INC •�;Slc� SHEET NAME SPEC SHEET PAGE NUMBBEERI REVISION SS 0 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat - Standard(s): Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev Product: PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page Iof1 ATM Issued: 9 -Apr -2019 ED 113.3.15 (24 -Apr -17) Mandatory **%W !LUE 1403 N RESEARCH WAY, BUILDING J OREM, UT 84097 800-377-4480 W WW.BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 ow of ,INC •�;Slc� SHEET NAME SPEC SHEET PAGE NUMBBEERI REVISION SS 0 Nor - BLUE RAVEN "T FLASHING &SLIDERS' am FR ; A Irl, 1 1403 N RESEARCH WAY. BUILDING J T N D€'� OREM, UT 84097 800-377-4480 am 0 Ri III I'! WWW.BLUERAVENSOLAR.COM --------------------------------------------------------------------------------------------------------------------------------------------- PILOT HOLES: Drill pilot holes for Lag screws or structural screws (as necessary) at marked attachement points FLASHINGS: Place flashings INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: • I n se rt flas h i ngs per manufacturer instructions NOTE: We Lag screw or structural fastener with a maximum diameter of 5/16" • Attach sliders to rafters • Verify p ro pe r row to row spacing for module size (Mad NS + 1') • Ensure that Tri mraitTM roof attachments in each row have sufficient engagement with slider dovetails for proper attachment. INSTALL SLIDERS AND ROOF ATTACHMENTS: Follow manufacturer instructions forflashing installation procedures MASON NOTE. if N-5 module edge ss o(;thin 1- of the shingle course above, Cosa have the option to pivot / rotate slider at the attachment point to span the next courae and cut shingles as required, (7o' 51.ii,�gles as Required ;;ate SUdc, —4 eIa --------- MIC,"JOLE EDGEIt -LessThan 0 II tl 11 li 0 1-j CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR �NPART TO OTHERS OUTSIDE RECIPIENTS ENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV�_ PV INSTALLATION PROFESSIONAL Scott Gurney # PV -011719-015866 CONTRACTOR: BRS FIELD OPS 385.498.6700 CA14 of SHEET NAME SPEC SHEET PAGE NUMBER I REVISION S 0 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: R Job Address: 3 p 3 Permit Number: 0) 7 0 / p d �... n N,9 Pr C, 7 ,'© N C (/ri0UC 71 17 A n 0.�-- 0 % je- u L) ❑ No one available for inspection: Time " ' AM/PM Re -Inspection require Yes No When corrections have bee e, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE '� 1 �.�,�� �✓ `� � OCCu atlr�We INSPEC ON RECORD INSPECTION REQUEST LINE: (303) 234-5933 IInspections will not be performed unless this card is posted on the project site. chic fkP ;ncnert;nn renne.Ct line hefore 11:59 D.M. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Initials Comments Pier Date Concrete Encased Ground (CEG) Foundation / P.E. Letter Initials .A\�f7.T_ffTIII Y_ T_T_'T'./_tT7.I'IT�Ti r-7 \ \ \/.\�4.��.��. FJ 1411\•IJ■■.� 91�"NlvI.A VV .\ �• ��.�... Date ... -_-� __ Inspector Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Rough Electric IJV\VL vv\ter. v■.MV• .v.....v. Rough Inspections �• ��.�... Date ... -_-� __ Inspector ____ _ CommentsInitials Wall Sheathing Mid -Roof Lath / Wail Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Inspector Date Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW &Drainage /Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof 2 Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits - mease oe sure rnaL ruuyn 1IMPUL IU110 QIG VVIIIVIV 11111 11 IV 1 .1. I-1— by ., .•by the Building Division. **For Inspection Time Window - Please email insptimerequest@Ci.wheatridge.Co.US by 8:00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather A A Uty 01 VV 11cat rKldgt Residential Roofing PERMIT - 201701002 PERMIT NO: 201701002 ISSUED: 05/30/2017 JOB ADDRESS: 3035 Chase ST EXPIRES: 05/30/2018 JOB DESCRIPTION: Tear off 1 layer existing roofing; Reroof with GAF Armorsheidl II IR 5/12 - 15 squares *** CONTACTS *** OWNER (303)725-4413 KOCH MARK C SUB (303)548-5000 Alan Parkes 021001 Roof Corp of Metro Denver Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA i Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,128.00 FEES Total Valuation 0.00 Use Tax 92.30 Permit Fee 140.90 ** TOTAL ** 233.20 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€TMs installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time o{ final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201701002 PERMIT NO: 201701002 ISSUED: 05/30/2017 JOB ADDRESS: 3035 Chase ST EXPIRES: 05/30/2018 JOB DESCRIPTION: Tear off 1 layer existing roofing; Reroof with GAF Armorsheidl II IR 51/12 - 15 squares *** CONTACTS *** OWNER (303)725-4413 KOCH MARK C SUB (303)548-5000 Alan Parkes 021001 Roof Corp of Metro Denver Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,128.00 FEES Total Valuation 0.00 Use Tax 92.30 Permit Fee 140.90 ** TOTAL ** 233.20 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€Ims installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201701002 PERMIT NO: 201701002 ISSUED: 05/30/2017 JOB ADDRESS: 3035 Chase ST EXPIRES: 05/30/2018 JOB DESCRIPTION: Tear off 1 layer existing roofing; Reroof with GAF Armorsheidl II IR 5/12 - 15 squares 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to, -be performed is disclosed -in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CON+' RACTOR (Circle one) Date 1. This permit was issued base on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees andprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of7 a W hezt4 1. I lege i i)1L11ti\lil' DI VI 101'MIN N I (-)Com., 1 � Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 \Jj Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(o-)d.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # 01 It 111 J Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: _✓ 0 3 5 C k a SP S f- Lv L r f 0.-j 9 e , co g O Z I Property Owner (please print): M ark Ko r Phone: 3 0 3) -72-,;- y I ( 3 Property Owner Email: ^'► °chock �, (o r , �, ••, Mailing Address: (if different than property address) Address: S Am E I S A 30 J E City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: Roo {cor9 -f Me � pe.,,jrr , 1 c Contractors City License #: 0 Z 100 1 Phone: (3o'0 7 6 b - 24'4 Contractor E-mail Address: P er f S ro o >C c o r p "' C Co en Sub Contractors: Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE fin/ ❑ NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING F] COMMERCIAL ADDITION RESIDENTIAL ROOFING 51v ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) _ Par Sq. FULF Amps - RorooIn Btu's GqF 15 s� Squares f 5 A,,.,v /- r 1! ,-r ( J -�j L 2 5/12- Gallons %12 Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) s—.-------5, I Z K— --- OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information prov lication. CIRCLE ONE: (OWNER)r(CONTRACTO!Li (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic SiLmature (first and last name): Wt t) u �/ /� �p DATE: S /73 DEPARTMENT USE ONLY ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer. OCCUPANCY CLASSIFICATION: Building Division Valuation: $ e CITY OF WHEAT RIDGE Building Inspection Division (/ (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: I)1 '1 I�- Job Address: _S 0 3 S C A P S r Permit Number: D, C� 1-7 6 I C G 011, ❑ No one available for inspection: Time/0 ab AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: t ; Inspector: DO NOT REMOVE THINOTICE Isluram FIf$4 T. ` Building Poffnft o M • t .. 5 Q) { W.A. CRY Lkwse ..� '_� .. , F. DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number: Date: 14936 12/13/02 Property Owner: MARK KOCH Property Address: 3035 CHASE ST Contractor License No. : 21486 Company: MGD Electric Phone: Phone: 480-9398 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: (OWNER)(CONTRACTOR) SIGNED ^ DATEk<-L:?o? Total: $1,000.00 $38.75 $0,00 $12.00 $50.75 [ hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wh at Ridg ordinances, for work under this permit. Use: Description: SERVICE CHANGE BUILDING DEPARTMENT USE ONLY !li\1ilfIIII':ii:Jii,.li'lIiIIiF"_ ~~ft~_~'" Approval: Zoning: SIC: Sq. Ft.: IIIlli11111l11i11l1l Approval: iiliulllii-_---"l _!.!lliI!!J._IIlIIII_~ Approval: Occupancy: Walts: Roof: Stories: Residential Units: Electrical License No : 21486 Company :MGD Electric Expiration Date: 2/28/03 Approval: OKlKS Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is nol commenced within sixty (60) days from issue dale or (8) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount nonnally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with suCcessive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provi' of the bui g codes or any other ordinance, law, rule or regulation. ~WHr4r ", ~ 0 - C> U ~ COL OR p,'iP DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPUCfTlON Building Permit Number: Date: Property Owner: )M a- r Ie /(0 c. "'- Property Address: 303SCN..sG Contractor License No,: SCJ C; 5 Company: M.Gr/J e-)~.c- Phone : Phone: 303 '1 go'<1~ 7% OWNElVCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (D.B.C) and all other applicable Wheat Ridge Ordinances. for work under this permit. (OWNER)(CONTRACTOR),SIGNED c.l)~ DATEI:J-.-I5'<>'2 DESCRIPTION: ..seY"vt~e G 4.ocvt~ e Construction Value:$ (CXJO Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ BUILDING DEPARTMENT USE ONLY I SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State oiColarado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if(A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. . (3) If this permit expires, a new pennitmay be acquired for a fee of one-half the amountnorrilally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty.four (24) hoUrs in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of. any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. Chief Building Inspector "~\k";",,,,, rt"" ,IJ"""""'''''''''''''',:r~''_''''''''~'.' ", ",,,,,,,,,,,,",,',",""Y,",,"",,,,,,,,""" +'.'"7"""~"W"'"","'}"""'~~"'''''''''"''''''''~'' I ", ". ",'",',>" ",J(;<h,,,,,,,,,,,,Ji;!, .' . DEPARTMEiNT OF PLAN. "...G AND DEVELOPMENT Building Permit Number: 2968 ..' BUILDING INS PE CTrfi, '. . DIVI SION - 235-2855 CITY OF T RIDGE Date: 4/24/96 7500 WEST TH AVENUE WHEAT RiDe, CO 80215 J: Property Owner: G~GHER VENITA H Property Address: 301 CHASE ST Contractor License No.: 17$p1 Company: Da~nburg Roofing Phone: 237-()549 Phone: 423 9513 J OWNER/CONTRACTOR SIGNATURE OIl UNDERSTANDING AND AGREEMENT ~~~tnot :=I~I~~0IIl?~~::ecolpro~',"'."~~~:fu~f::~1~:~~1::ts madIe are accurate; lh,tl have ..., and 'abide by all conditions printad on this application, and thall...ume fuR reepons' r compHance with the Whaat Ridge Building Code (U.B.C,) and all other appIk:&bIe . ordinances, for work undar this pennK. }~: Construction Value : Permit Fee : Plan Review Fee : UseTax: Description: TE ~-,...-?~ Total: $2,305.00 $54,00 $0.00 $34.58 $88.58 (OWNER)(CONTRACTOR) SIGNED REROO BUILDING DEPARTMENT USE ONLY Approval: Occupancy: Walls: Roof: Stories : Residential Units : Electrical License Nb : Company: >"., ;;; Plumbing License No : , Company: Mechanical License No : Company: Expiration Date : Approval: , Expiration Date: , Approval: Expiration Date : Approval: . j. . " ' i~ (1) TIIlI pet111I '1 was _ In_ wi~" prQYisionS setlorth In yopur """'icatIon and Is 8UbIect to 1ha _ of the state of COlorado and to the Zoning RegUla_ and 8\lIIdinllCOda of_ , ~ or any other applicable _ of the CIW. (2) ~n~== ~20~ a "i 18 not - within sixty (60) daylllOm Isoue date or (8) tho buiIdlng authorized Is auspOndad or (3) W!hls porrnilOlq3lills. . _ porrnil_ b8~" Irad for alee of one-haW tho amount normelly requlrad, providad no changos have _ or will b8 made In tho original plans and~, _ and.ny ,lion or abendonmenl hu not excaedad ana (1) year. W ch8ngas'l8 m8d8 or W suspanslon or abendonmenl 8ICCeedS ana (1) _; rutl_ 8haH b8 jIald', a now porrnil, (4.1 No work of any __ b8 done that 'thonga the natural flow of w_ coutlnO a dralnago probIam. ( COntracto,:g~ ~~uIldIni I~, " .four (24) hOUNlln advanc8 for all fnopactlons and shaH I8COIva wrltlen approval on InapectlOn card bafora (S) ~. ,', . Of. permit or ~I . '. ngs and specifications shall not be conabued to be a permit for, nor an approval of, any violation of the provisions _ any 0 ce,'\lJlw, rule or regulation. IE!f Building InSpector THIS PERMIT VALIObNL Y WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR C~~2-fif~TO~- DEPARTMENT OF PLI liNG AND DEVELOPMENT BUILDING INSPEC110N DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: 0 '). r - <'I- <j~ Property Owner: Property Address: Contractor License No. : Company: Co, II ", i--,e~ 30 3S-' Cj.,as~ 1/hO I D.,JI/~" b" " f< oo{,':-, Phone: 237-05"'11 Phone: '123-'1;-(3 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: If 2. 3 os- , Permit Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown. and allegations made are accurate; that I have read and a~ree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and aU other applicable Wheat Ridge ordinances. for work under this permit. (OWNER)(CONTRACTOR)SIGNED ~~ i)~ DATE '1-2.f-9~ D .. P I~ ,0 , t/ . eSCrlptlon : ,..<, ..... 0\-4>"l) . e...- Total: ONLY !.'J,flI.iJ"t!~I~'fll~l( Jli_~l' Approval: Zoning: I,Wllijl!J~Hl'II Approval: Dllbl'c'W~:!mlttl- -....'1 ~''''''~ I, ~ . .nloD_. Approval: Occu ai1cy: Walls: Roof: { 7 I:J Stories: 2-. Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: ~ :,-PlahsRAAu!redJ;2}] Expiration Date: Approval: liI ,Plans, ,I~equired _J Expiration Date: Approval: ill !!P~~I!.I(iJRfi&!!'i1 (1) (2) (3) This permIt was issued in accordance with the provisions set forth in yopur application and IS subject to the laws of the Stale of Colorado and to the Zoning Regulations and BUilding Code of VV'heat Ridge. Colorado or any other applicable ordmances of the City. This permit shall exp:ire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned tor a penod of 120 days. If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required. proV'ided no changes have been or will be made in the origenal plans and specifications and any suspenSion or abandonment has not exceeded one (1) year. If changes are made or If suspenSion or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem Contractor shaH notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receiV'e written approV'al on inspection card before proceedimg with successive phases of the lob. The Issuance of a permIt or the approval of drawings and specifications shalll'lOt be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION