3137 Chase Street
4' �i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time f' M/ M Re -Inspection required: YeVN When corrections have been made, for re -inspection online at: http✓/www. ci. wheatridge. co. us4inspection Dater-� Inspector: -- - DO NOT REMOVE THIS NOTICE 1*�441 CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: ? Permit Number: -Z S^` J No one available for inspection: Tim �� _;; M Re -Inspection required: YescfN- ''When corrections have been made, schedule for re -inspection online at: http✓/www, ci, wheatridge, co. uslinspection Dates - 2I! 24t-' �spector: DO NOT REMCVE`THIS NOTICE City of Wheat Ridge Residential Mechanical PERMIT - 202000235 PERMIT NO: 202000235 ISSUED: 02/04/2020 JOB ADDRESS: 3137 Chase St EXPIRES: 02/03/2021 JOB DESCRIPTION: Replacing gas insert to existing gas line. **REVISION: Added one receptacle for fireplace insert. Added valuation: $300 **REVISION: Installation of gas insert and chase cap. Repair flue lines. No added valuation. *** CONTACTS *** OWNER (720)209-9422 ABELL JOEL STEPHEN SUB (303)466-4206 GREG FANGER & KEVIN FANGER 017986 THE GAS CONNECTION SUB (303)974-5273 RICH HARSHMAN 190214 H & H ELECTRIC SUB (303)973-7376 JON GEYPENS 202044 CHIMNEY SWEEPS OF AMERICA *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,500.00 FEES Total Valuation 0.00 Use Tax 115.50 Permit Fee 140.90 ** TOTAL ** 256.40 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES 41 City of Wheat Ridge Residential Mechanical PERMIT - 202000235 PERMIT NO: 202000235 ISSUED: 02/04/2020 JOB ADDRESS: 3137 Chase St EXPIRES: 02/03/2021 JOB DESCRIPTION: Replacing gas insert to existing gas line. **REVISION: Added one receptacle for fireplace insert. Added valuation: $300 **REVISION: Installation of gas insert and chase cap. Repair flue lines. No added valuation. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,pennit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Bate 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This, ermit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original ermit fee. 3. if this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change. of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services 6, Thrince or granti of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any apa code or an dinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat P.....dge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permits(a-)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Add to Permit # C5�� ot)o q 3S- Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print):) 1G�nnr;; /� Phone: Property Owner Email:_{-7��?L;! Mailing Address: (if different than property address) Address: City, State, Zip: 1, V, J6uPed5 C? it Contact Person: mc7�,,'en Phone: X3,;3) 13 "" 7376, Contractor: i Contractors City License #: Contractor E-mail Address: Phone: Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour— 2 hour minimum). Description of revised/amended work: r^ l���a�, S a % Srr C'�'e�}'c. C'� I L, J'oP , 6' f I u C //,I c'!5 Sq. Ft./LF Amps Btu's Squares Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or(AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: / 1 L �� SIGNATURE: (C /l'�/�� DATE: ,, , 2 ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ D1LaVl5� V. City of 40 Wheat � COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FO I Mechanical Subcontractor This form must be completed & signed by the MECHANICAL SUBCONTR. performing mechanical work on site. Subcontractor's insurance and license must be up to date prior to permit is Project Address: 31 Y] t hw t, S'f. L)Wki I4 d+s- , 6.0 N2,1 General Contractor: 11 M n P -u 's t, ) op -DS Company Name: SO S 8 fAW U Contact Phone Wheat Ridge Contractor License #: 20 u vg (required field) Printed Name of A16thorized Agent qnA•52� Signature of AuthorizefliAgent Date t City of Wheat Ridge Residential Mechanical PERMIT - 202000235 PERMIT NO: 202000235 ISSUED: 02/04/2020 JOB ADDRESS: 3137 Chase St EXPIRES: 02/03/2021 JOB DESCRIPTION: Replacing gas insert to existing gas line. **REVISION: Added one receptacle for fireplace insert. Added valuation: $300 *** CONTACTS *** OWNER (720)209-9422 ABELL JOEL STEPHEN SUB (303)466-4206 GREG FANGER & KEVIN FANGER 017986 THE GAS CONNECTION SUB (303)974-5273 RICH HARSHMAN 190214 H & H ELECTRIC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,500.00 FEES Total Valuation 0.00 Use Tax 115.50 Permit Fee 140.90 ** TOTAL ** 256.40 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES � 44 City of Wheat Ridge Residential Mechanical PERMIT - 202000235 PERMIT NO: 202000235 ISSUED: 02/04/2020 JOB ADDRESS: 3137 Chase St EXPIRES: 02/03/2021 JOB DESCRIPTION: Replacing gas insert to existing gas line. **REVISION: Added one receptacle for fireplace insert. Added valuation: $300 I by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this_permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be pertormed and th t Aa/Ilko be performed is disclosed in this document and/or its' accompanyin approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po Flans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit tee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granti of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applic,e code or anypydinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of RW heat �g� C OMY MUNiTDFYr.1,0PMENT Building & Inspection Services Division 7500 W. 29t1 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permitsaci.wheatridge.co.us FOR OFFICE USE ONLY Date: Add to Permit # �J Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3 Q z 4�� 5r__ S4 Property Owner (please print): Phone: Property Owner Email: An 2�7z & '®Ez- Mailing Address: (if different than property address) Address: City, State, Zip: Submitting Company: tl,14/ Contact Person: ���///L �l Phone:L� Contractor: if � ? �� 61--6 G / /) 4 Contractors City License #: Contractor E-mail Address: Phone: 30 3 -Z 0 tj- C �-©� ! 7 X/L 3l7W I Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour - 2 hour minimum). Description of revised/amended work: / ' 1�Ov11SA Sq. Ft./LF Amps Btu's Squares Gallons Other Additional /Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) ;300 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) 6;C or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NADIE: "" N / //f /`/ 1� / SIGNATURE: DATE: ! (/ ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received Water District ❑ Received Sanitation District ❑ Received DEPARTMENT USE ONLY ❑ Not Required ❑ Not Required ❑ Not Required OCCUPANCY CLASSIFICATION: Building Division Valuation: $ k- iry or Wh6atpidge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 2, -F / Cyg, 5%- r General Contractor: FORM WILL NOT BE ACCEPTED WITH MISSING INFORMATION Company Name: (r/ e Contact Phone #:_3�— 20� � g Wheat Ridge Contractor License #: [ ( (required field) State License #: (O (0Master License #: �CJ / 04 Printed Name of Authorized Agent (�,� x0ex - Signature of Authorized Agent -ZI 7 �� zO Date A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: (►�..�- - Job Address: Permit Number: -2c, `�_ 0�'`'. ❑ No one available for inspection: Tires _ ZSn&PM Re -Inspection required: Yeg No -,ii When corrections have been made, schgdule for re -inspection online at: http.lwww.ci.wheatridge.co.usVinspection),__ _ City of Wheat Ridge Residential Mechanical PERMIT - 202000235 PERMIT NO: 202000235 ISSUED: 02/04/2020 JOB ADDRESS: 3137 Chase St EXPIRES: 02/03/2021 JOB DESCRIPTION: Replacing gas insert to existing gas line. *** CONTACTS *** OWNER (720)209-9422 ABELL JOEL STEPHEN *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,200.00 FEES Total Valuation 0.00 Use Tax 109.20 Permit Fee 140.90 ** TOTAL ** 250.10 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,permit. I further attesi that I am legally authorized to include all entities named within this document as parties to the work to be performed and that alb w9r"go be pe�� ed is disclosed in this document and/or its' accompanying approved plans and specifications. ted„ Z •a ' Zfl2® Signature of OWNER or C TRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance orgrant° of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any r?aae code or an rdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat Nijclge ,o�9 Building & Inspection Services 7500 W. 29' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cD_ci.wheatridge.co.us FOR OFFICE USE ONLY Date: d0�z) PIMP rmif # `� K) &1) Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 31 (,-�q '&ase- Sk-- Property Owner (please print) Lmm Dor=1ke- Phonelw-ZZ9 -C�4ZZ Property Owner Email: uC'A�0�\ J-40& (.AaVn . CbA\ Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State Architect/Engineer: Architect/Engineer E-mail: Contractor Name��,Q„ GoS CQm-,_QC.kn1/1 Phone: /7C1-1t,Q-i„ ��.n V _1 —celr)� City of Wheat Ridge License #: V---)1 T`I OW Phone: `-A�Sp �-`�L-P Contractor E-mail Address For Plan Review Questions & Comments (please print): CONTACT NAME (please print): CONTACT EMAIL(p/ease print): Phone: �S • (lu/ _ Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # ❑COMMERCIAL [RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. �4tH� o4� "\vise . �o �-ew as Me, 1 i g � Sq. Ft./LF BTUs Gallons Amps Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ 5-2co C, OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (C C or (AUTHORIZED SENTATIVE) of (OWNEf) CONTRACTOR) Sienature (first and last na e): �p DATE: Printed Name:) t I V\�filVn4 ril t _ DEPARTMENT USE ONLY ZONING COMMMENTS: i OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: Building Division Valuation: aZ�x.�r 2. y. INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE. CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22 AND ANSI Z21.50 FOR VENTED GAS FIREPLACES. SAFETY INFORMATION If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the supplier. XIR3N NATURAL GAS XI R3P PROPANE SqF Ty q RRIER WARNING: FOR INDOOR USE ONLY IYA a HOT GLASS WILL CAUSE BURNS. This appliance may be installed in an aftermarket, permanently located, DO NOT TOUCH GLASS UNTIL manufactured home (USA only) or mobile COOLED. home, where not prohibited by local codes. This appliance is only for use with the type lot NEVER ALLOW CHILDREN TO TOUCH GLASS. of gas Indicated on the rating plate. This appliance is not convertible for use with A barrier designed to reduce the risk of burns from other gases, unless a certified kit is used. the hot viewing glass is provided with this applianc and shall be installed for the protection of children $ yryy and other at -risk individuals. Q.a,ry sy.rem cn�rea ro 0 �A B�, BARRIER ■/M9O p 900 7 -2008 W415-1343 / A / 11.18.16 2 TABLE OF CONTENTS fit NOTE: The camera icon indicates video tutorials are available as additional reference, visit NOTE: changes, other than editorial, are denoted by a vertical line in the margin. W415-1343 / A/ 11.18.16 http://mynapoleon.napoleonproducts.com/download/index/44/1 1.0 INSTALLATION OVERVIEW 3 2.0 INTRODUCTION 4 2.1 DIMENSIONS 5 5 2.2 MINIMUM CLEARANCE TO COMBUSTIBLES 2.3 GENERAL INSTRUCTIONS 5 2.4 GENERAL INFORMATION 6 2.5 RATING PLATE INFORMATION 7 3.0 INSTALLATION 8 3.1 LEVELLING THE APPLIANCE 8 3.2 CHIMNEY CONNECTION 9 3.3 GAS INSTALLATION 10 4.0 FINISHING 11 4.1 MINIMUM COMBUSTIBLE MANTEL CLEARANCES 11 4.2 SAFETY SCREEN & DOOR REMOVAL / INSTALLATION 12 4.3 LOG PLACEMENT 13 4.4 OPTIONAL ROCK PLACEMENT 14 4.5 GLOWING EMBERS 14 14 4.6 LOGO PLACEMENT 15 4.7 BATTERY INSTALLATION 5.0 ELECTRICAL INFORMATION 16 5.1 WIRING DIAGRAM 16 6.0 OPERATION 17 6.1 OPERATING AND LIGHTING INSTRUCTIONS 17 6.2 XIR3 OPERATION 18 6.2.1 GENERAL TRANSMITTER LAYOUT 18 6.2.2 APPLIANCE OPERATION 18 6.2.3 HAND HELD REMOTE OPERATIONS 18 6.2.4 TEMPERATURE DISPLAY 19 6.2.5 ROOM THERMOSTAT 19 19 6.2.6 SMART THERMOSTAT 19 6.2.7 FLAME HEIGHT 20 6.2.8 CHILD PROOF FUNCTION 6.2.9 NIGHT LIGHT 20 20 6.2.10 LOW BATTERY / MANUAL BYPASS 20 6.2.11 IN THE EVENT OF A POWER FAILURE 6.2.12 CONTROL MODULE 20 21 6.2.13 SPLIT FLOW VALVE 21 6.2.14 TIMED BLOWER 21 6.3 ANTI CONDENSATION CONTROL SWITCH 7.0 ADJUSTMENTS 22 7.1 PILOT BURNER ADJUSTMENT 22 7.2 VENTURI ADJUSTMENT 22 7.3 FLAME CHARACTERISTICS 23 8.0 MAINTENANCE 24 8.1 ANNUAL MAINTENANCE 24 8.2 CARE OF GLASS 25 25 8.3 CARE OF PLATED PARTS 8.4 DOOR GLASS REPLACEMENT 25 8.5 BURNER REMOVAL 26 8.6 FCM REPLACEMENT 26 8.7 NIGHT LIGHT- REPLACEMENT 27 8.8 VALVE TRAIN REPLACEMENT 27 9.0 REPLACEMENTS 28 9.1 OVERVIEW 29 30 9.2 OVERVIEW (PG. 2) 9.3 VALVE TRAIN ASSEMBLY 31 9.4 FIREBOX TOP ASSEMBLY 32 10.0 ACCESSORIES 33 10.1 ACCESSORIES (PG. 2) 34 11.0 TROUBLESHOOTING 35 12.0 WARRANTY 38 13.0 SERVICE HISTORY 39 14.0 NOTES 40 NOTE: changes, other than editorial, are denoted by a vertical line in the margin. W415-1343 / A/ 11.18.16 1.0 INSTALLATION OVERVIEW Rating Plate, se, PLATE INFORM section. Batteries, see "BATTER Receiver, see °PROGR) 0 Venting, see "INSTALLATION - CHIMNEY CONNECTION" Logs, see "FINISHING - LOG PLACEMENT' section. Batteries must be disposed of according to the local laws and regulations. Some batteries may be recycled, and may be accepted for disposal at your local recycling center. Check with your municipality for recycling instructions. W415-1343/ A/ 11.18.16 3 • 4 2.0 INTRODUCTIO • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fire or injury. • Risk of fire or asphyxiation do not operate appliance with fixed glass removed. • Do not connect 110 volts to the control valve. • Risk of burns. The appliance should be turned off and cooled before servicing. • Do not install damaged, incomplete or substitute components. • Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may be sharp. • Do not burn wood or other materials in this appliance. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to an appliance, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. Clothing or other flammable material should not be placed on or near the appliance. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces. Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time. Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the floor. Any safety screen, guard or barrier removed for servicing the appliance, must be replaced prior to operating the appliance. The appliance is a vented gas-fired appliance. Do not burn wood or other materials in the appliance It is imperative that the control compartments, burners and circulating blower and its passageway in the appliance and venting system are kept clean. The appliance and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids. Under no circumstances should this appliance be modified. This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Do not strike or slam shut the appliance glass door. When equipped with pressure relief doors, they must be kept closed while the appliance is operating to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause the surrounding combustible materials to overheat and catch fire. Only doors / optional fronts certified with the appliance are to be installed on the appliance. Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all plastic bags, these are not toys and should be kept away from children and infants. As with any combustion appliance, we recommend having your appliance regularly inspected and serviced as well as having a Carbon Monoxide Detector installed in the same area to defend you and your family against Carbon Monoxide. Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage of decorations, a T.V. or other electronic components. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's barrier for this appliance. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. 3.2C W415-1343 / A / 11.18.16 5 2.1 DIMENSIONS 21" [ 533mm] 201/2" [521mm] i 22 7/8" == � [581mm] 171/2" 91/2' _- [445mm] [241mm] -- 12 2[305mm] f-171/2" [445mm] REQUIRED DIMENSION WITH THE OPTIONAL BLOWER KIT INSTALLED. 2.2 MINIMUM CLEARANCE TO COMBUSTIBLES 2.3 131/4" [337mm] 1-29 5/8" [753mm]� This appliance must be recessed into a vented noncombustible wood -burning appliance (prefabricated or masonry) only. The minimum appliance opening size in which the appliance is to be installed is: HEIGHT 211/2" (54.6cm) WIDTH 29" (73.7cm) DEPTH *131/2" (34.3cm) The minimum allowable chimney flue size is 7" (177.8mm) round. *Add 4" (102mm) for optional blower. The minimum distance, from the bottom of a combustible mantel projecting 3" (76mm) maximum from the wall to the top of the appliance, is 14" (35.6cm) (See MINIMUM MANTEL CLEARANCES section). NOTE: A NON-COMBUSTIBLE HEARTH MUST PROTRUDE A MINIMUM OF 12" (30.5cm) FROM THE APPLIANCE. GENERAL INSTRUCTIONS ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48 INCHES (121.9cm) FROM THE FRONT FACE OF THE APPLIANCE. SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT WHEN THE APPLIANCE IS OPERATING. FIRE RISK. EXPLOSION HAZARD. HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (35mb). USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON -LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION. THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area, for example in Massachusetts State: • This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts. • The appliance damper must be removed or welded in the open position prior to installation of an appliance insert or gas log. • The appliance off valve must be a "T" handle gas cock. • The flexible connector must not be longer than 36 inches (91.4cm). • A Carbon Monoxide detector is required in all rooms containing gas fired appliances. W415-1343 / A / 11. 18.16 A A Carbon Monoxide detector is required in all rooms containing gas fired appliances. The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product. The installation must conform with local codes or, in absence of local codes, the National Gas and Propane Installation Code CSA 8149.1 in Canada, or the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States. Suitable for mobile home installation if installed in accordance with the current standard CAN/CSAZ240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1 and NFPA 54 in the United States. F REPLACE ONAL We suggest that our gas INSTITUTE` hearth products be installed 0-4,500 and serviced by professionals 11 who are certified in the U.S. 31,000 by the National Fireplace 24,800 Institute® (NFI) as NFI Gas CERTIFIED Specialists www.nficertified.org A.F.U.E. (maximum value) Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States. 4.12A 2.4 GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST -FIRED TO ASSURE ITS OPERATION AND QUALITY! When the appliance is installed at elevations above 4,500ft (1371 m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected. This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and bed -sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation in a mobile home that is permanently positioned on its site and fuelled with natural gas. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must be installed. Canada ENERQUIDE rCgSy0A%GsF6. .-"—XIR3 W415-1343 / A / 11. 18.16 NG P Altitude (FT) 0-4,500 0-4,500 Max. Input (BTU/HR) 31,000 31,000 Max. Output (BTU/HR) 24,800 24,800 Efficiency (w/the fan on) 80% 80% A.F.U.E. (maximum value) 77% 77% Min. Inlet Gas Supply Pressure 4.5"(11 mb) WC 11 "(27mb) WC Max. Inlet Gas Supply Pressure 13"(32mb) WC 13"(32mb) WC Manifold Pressure (Under Flow Conditions) 3.5"(9mb) WC 10"(25mb) WC When the appliance is installed at elevations above 4,500ft (1371 m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected. This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and bed -sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation in a mobile home that is permanently positioned on its site and fuelled with natural gas. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and must be installed. Canada ENERQUIDE rCgSy0A%GsF6. .-"—XIR3 W415-1343 / A / 11. 18.16 7 2.5 RATING PLATE INFORMATION CONFORMS TO I CONFORME AUX: ANSI; DO NOT TURN ON IF CHILDREN OR OTHER AT RISK INDIVIDUALS ARE NEAR THE FIREPLACE. DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED -SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CANICSAZ24OMH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI I NFPA 501A.FOR USE WITH BARRIER W565-0133. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL NATURAL GAS I GAZ MODEL NE VAS ALLUMER SIDESVPLELASETTE I RISQUE SONT A PROXIMITE DU FOYER. FOYUR INSTALLATION DANS UNE CHAMBRE A COUCSTUDIO. APPROPRIE POUR INSTALLATION DANS UNESIAL FILE D EST SP &SUE XIGENCES D0 AHS RIE DE MAISONS S AU GAZ, ENOU AUX STATS-UNIS, SELON n11nc URITE ET DEISONS MANUFACTUREES, TION 3260. DNORMS DES ETATSUNIS CERTIFIED FOR CANADA USA LEE, SE REF LA NORME RELATIVE AU CRITERE DE CERTIFIES POUR CONTR IE POUR LES INSTALLATIONS DANS LES REFERENCE 0161746 LE ES COMMUNAUTES, ANSIMFPA 501A. 5-0133. SUWEZ LES INSTRUCTIONS LE MANUEL D'INSTALLATION. XIR3N ❑ CXIR3N ❑ MODEL 450OFT(0-1370.)'LT" Lf 31,000 BTU1h INPUTIAL 11,000 BTUihREDUCED INPU MANIFOLD PRESSURE: 3.5 WATER COLU PRESSION AU COLLECTEUR: 3.5' DUNE COLONNE D'E4 MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUM PRESSION WAUMENTATION MINIMALE: 4.5' D'UNE COLONNE DEAL) MAXIMUM SUPPLY PRESSURE: 7.0" VVR COLUMN PERSSION D'AUMENTATION MAXIMALE: 7.0" DUNE D'EAU THIS VENTED GAS FIREPLACE IS NOT FOR USE WIT7% AIR FILTERS, FOR USE WITH GLASS DOORS CER IFI FOR THIS UNIT ONLY. NOT FOR USE WITH SOLID FUEL. WARNINGDO NOTADD ANY MATERIAL TO THEAPPLIANCET WILL COMEIN CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLE NUFACTURE WITH THE APPLIANCE. DECORATIVE PRODUCT: NOT FOR USE AS A HEATING A ELECTRICAL RATING: 115V 1.5AMP 6OHZ MINIMUM OPTIONAL FAN KIT - GZ550-KT WOLF STEEL LTD. 24 NAPOLEON ROAD. BARRIE. ISP ® E] CAW 450OFT (0-1370.) 31,000 BTUIh 16,000 BTUVh WATER COLUMN R: 10" DUNE COLONNE D'EAU MEN�MINRpALE: 11D'UNE COLONNE D'EAU Y PRE RE: 13" WATER COLUMN NTATION MAXIMALE: 13" DUNE COLONNE D'EAU ER A GAZ VENTILES NE D01T PAS ETRE UTILISE C JOINTEMItNT AVEC DES %TRES A AIR. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES AVEC CETTE UNITE SEULE• MENT. UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL. AVERTISSEMENT: N'A JOUTEZ PAS ACETAPPAREILAUCUN MATERIAU DEVANT ENTRER EN CONTACTAVEC LES FLAMMESAUTRE QUE CELUI QU1 EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT. PROOUIT DECORATIF: NE PAS UTILSER COMME APPAREIL DE CHAUFFAGE. CLASS: 115V, I,SAMP, 60HZ LAPPAREIL D01T EVACUER SES GAZ EN UTIUSANT UENSEMBLE D'EVACUATION PROPRE A WOLF STEEL REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR VEVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER LEVENT APRES AVOIR ASSURE LE MAINTIEN DO SYSTEME DE PRISE D'AIR. ATTENTION: POUR INSTALLATION DANS ON FOYER VENTILE EN MACONNERIE. LES DIMENSIONS MINIMUMS SONT: HAUTER 21 S', PROFONDEUR 135', LARGEUR 29'. LE DIAMETRE INTERIEUR MINIMUM DE CONDUIT DEVACUATION EST DE T. LA DISTANCE MINIMALE, DO BAS DO MANTEAU COMBUSTIBLE FORMANT ONE PROJECTION MAXIMALE DE T DO MUR ALL DESSUS DE LA GARNITURE NORMALE EST 14'. REFERER AU MANUEL D'INSTALLATICN POUR DES EXTENSIONS PLUS GRANDES.SOUFFLERIE OPPONELLEGZ550-KT, GD65. SERIAL NUMBER/NO. DE SERIE' „„„—.,,,- INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the model, venting and gas type of the appliance. For rating plate location, see "INSTALLATION OVERVIEW” section. This illustration is for reference only. Refer to the rating plate on the appliance for accurate information. NOTE: The rating plate must remain with the appliance at all times. It must not be removed. W415-1343 / A / 11.18.16 E:3 3.0 INSTALLATION RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. Clean out ashes from the inside of the wood -burning appliance. Make sure that the chimney and wood -burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualified person before installing the insert. Remove the existing appliance damper or lock into an open position. Using screws, attach the appliance warning tag to the inside of the firebox of the appliance into which the insert is being installed. The sheet -metal parts of the appliance, in which the gas appliance insert is to be installed, must not be cut. WAKNINU: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE -APPROVED BY THE AUTHORITY HAVING JURISDICTION. ATTENTION. CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT O COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU O TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES AVANT JURIDICTION. ADVERTENCIA. ESTACHIMENEASE REMODELO PARA USARSE SOLO CON UNA INSERCON DE CHIMENEAA GAS Y NO PUEDE USARSE PARA QUEMAR MADERA NI COMBUSTIBLES S6LIDOS, A MENOS QUE SE HAYAN REEMPLAZADO TODAS LAS PIEZAS ORIGINALES, Y LAAUTORI- ,DAD JURISDICCIONAL LA HAYA VUELTO AAPROBAR If the wood -burning factory -built appliance has no gas access hole(s) provided, an access hole of 1'h inch (38.1 mm) or less may be drilled through the lower sides or bottom of the appliance in a proper workman like manner. This access hole must be plugged with non- combustible insulation after the gas supply line has been installed. Ensure that existing chimney cleanouts fit properly. The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the existing appliance before installing the gas appliance insert. Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. The ventilation openings in the existing appliance may be obstructed by the backer plates, aluminium trim etc. but these parts are not to be applied so as to have an airtight seal. 68.46 a 3.1 LEVELLING THE APPLIANCE Move the appliance close to its final position. This appliance is equipped with levelling screws located on the base. Level using the levelling screws. Levelling the appliance will eliminate rocking or excessive noise when the fan is in operation. Once the appliance is level, move it partially into place to allow for all connections to be made. It is not practical to level the appliance once it has been installed. Determine the required depth prior to installing the appliance and adjust the levelling screws accordingly. 67.2 W415-1343 / A / 11. 18.16 9 3.2 CHIMNEY CONNECTION Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and naximum vent lengths are 10' (3m) and 35' (10m) respectively. Recommended kits come in 3 lengths: 2-3" (50.8mm-76.2mm) DOUBLE PLY ALUMINUM LINER -INLET AND EXHAUST: GDI-320KT VENT KIT 20FT GDI-325KT VENT KIT 25 FT GDI-335KT VENT KIT 35 FT While the liners must be continuous from the appliance to the chimney cap, to achieve the needed length, they may be coupled, using an approved coupler. We recommend that exhaust vents that pass through unheated spaces, FLASHING such as tall exterior chimneys, be wrapped in a protective sleeve to minimize PLATE condensation and reverse flow symptoms. See "TROUBLESHOOTING" section for details. EXHAUST 2" (50.8mm) 'OVERLAP This appliance is approved for use with a 3" (76mm) exhaust and air intake. SEALANT INTAKE HI -TEMP A. OUTSIDE: Slip the one end of a liner a minimum of 2"( 51 mm) over the sleeve of the air terminal. Secure using 3 screws. Then seal the joint and screw heads with high temperature sealant. Repeat with the other liner. B. NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the exhaust liner being connected 3" (76.2mm) to the intake collar at the LINERS appliance. Gently stretch the liners to the required lengths and insert into the chimney. Trim and fit LIDS HIGH TEMP the flashing plate to suit the SEALANT - chimney termination. Place the MOUNTING 2" (50.8mm) f� PLATE air terminal onto the top of the OVERLAP chimney. Make weather tight by sealing with caulking (not VENT MOUNT supplied). Fasten to the chimney ASSEMBLY with screws and plugs (not supplied). C. INSIDE: Remove the securing screw from the front of the vent mounting plate. Pull the vent mounting plate only, back into the track, to the front stop. Start the slider back into position. Re - secure the screw. The appliance may now be pushed into its final position inside the wood burning appliance, and the screw tightened until the slider has been pulled tight to the front stop. SECURING SCREW D. Route the flex liners through the slider. Attach and secure the liners to the vent mounting plate using the same procedure as before, ensuring that the marked exhaust liner is attached to the exhaust collar. W415-1343 / A / 11. 18.16 10 3.3 GAS INSTALLATION Mm�4. RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND ELECTRICAL LOCATIONS, SEE "DIMENSIONS" SECTION. ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE. HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS LINE AT TEST PRESSURES ABOVE 1/2 PSIG. VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE. Installation and servicing to be done by a qualified installer. • Move the appliance into position and secure. • If equipped with a flex connector the appliance is designed to accept a 1/2" (13mm) gas supply. Without the connector it is designed to accept a 3/8" (9.5mm) gas supply. The appliance is equipped with a manual shut off valve to turn off the gas supply to the appliance. • Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current CAN/CSA-13149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States. • When flexing any gas line, support the gas valve so that the lines are not bent or kinked. • The gas line flex -connector should be installed to provide sufficient movement for shifting the burner assembly on its side to aid with servicing components. • Check for gas leaks by brushing on a soap and water solution. Do not use open flame. 30.1 A W415-1343 / A / 11. 18.16 4.0 FINISHING 4.1 11 72.1 B MINIMUM COMBUSTIBLE MANTEL CLEARANCES RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED. WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION. 73.1 Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. These same requirements apply to any combustibles protruding on either side of the appliance. A M H A E B N I T G E H C L T D 0" (mm) F E MANTELDEPTH Ref DIMENSIONSMANTEL Height Ref Depth A 17" (43.2cm) E 6" (152mm) B 16" (40.6cm) F 5" (127mm) C 15" (38.1 cm) G 4" (102mm) D 14" (35.6cm) H 3" (76mm) 6"(152.4mm) MANTEL 5"(127mm) 4"(101.6mm) 17„ " (76.2mm) (43.2cm) 16" (40.6cm) 15" (38.1 cm) 14" (35.6cm) 20'/2" (52.1 cm) G W415-1343 / A / 11. 18.16 12 fit 4.2 SAFETY SCREEN & DOOR REMOVAL / INSTALLATION GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. IF EQUIPPED WITH DOOR LATCHES THAT ARE PART OF A SAFETY RELIEF SYSTEM, THEY MUST BE PROPERLY ENGAGED. DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED. FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS, LOUVRE OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS. BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE. 75.1A A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and shall be installed. Before the glass door can be removed, the safety screen must be removed. Lift the safety screen off the 4 side pins and remove from the appliance. The optional front must be removed to allow the door to be opened or closed. Release the top left and right door latches, located at the top of the door. Tilt forward and lift from slots. Reverse these steps to re -install the safety screen and door. Ensure safety screen is installed correctly. W415-1343 / A / 11.18.16 i 7- it 13 4.3 LOG PLACEMENT T6.1A PHAZERTM logs and glowing embers exclusive to Napoleon, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour pigments burn in during the heat activated curing process. NOTE: Log support brackets are supplied in the manual baggie. SUPPORT A. Place the rear log into position B. Insert a pin (supplied) into the lining up the holes in the bottom with right end of the left middle log the studs located at the rear of the using the left log support in front firebox. Ensure it is tight to the burner. of the left middle log to hold log in place. D. Place the left front log into position, lining up the 2 holes in the bottom with the studs located on the left side of the burner. G. Position the right charcoal strip in front of the right front log, lining up the 2 holes in the bottom with the 2 front right studs. E. Place the right front log into position, lining up the 2 holes in the bottom with the studs located on the right side of the burner. H. Position a pin into the left side hole of the left middle log, move the left crossover log into position, lining up the top hole with the pin. C. Insert the right middle log end onto the left log pin using the right log support in front of the right middle log to hold log in place. Adjust the log supports tight to these logs to hold them in an upright position and ensure they are [o the burner. F. Position the left charcoal strip in front of the left front log, lining up the 2 holes in the bottom with the 2 front left studs. I. Position a pin into the right side hole of the right middle log, move the right crossover log into position, lining up the top hole with the pin. W415-1343 / A / 11. 18.16 14 It 4.4 OPTIONAL ROCK PLACEMENT REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE. HEAT WILL CAUSE THEM TO EXPLODE Before beginning with the installation, remove the door and all burner media from the appliance including logs and charcoal strips. Retain the glowing embers. A. Randomly place the rocks onto the media tray, around, but not on the burner ports or pilot area. B. Rocks can be carefully stacked. You must ensure that none would fall onto the burner or pilot while in operation. C. Turn on gas and electrical supply. D. Reinstall the glowing embers over the burner. E. Reinstall the door. 4.5 GLOWING EMBERS Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fibre hairs will glow. The ember material will only glow when exposed to direct flame; however, care should be taken to not block the burner ports. Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZERT11 logs glow when exposed to direct flame. Use only certified "glowing embers" and PHAZERTM logs available from your authorized dealer / distributor. 4.6 LOGO PLACEMENT Remove the backing of the logo supplied and place on the glass viewing door, as indicated. W415-1343 / A / 11.18.16 �2(12.7mm) LOGO ��2 "(12.7mm) - 97.1A 4.7 BATTERY INSTALLATION 4 "AA" batteries must be installed into the receiver before operation is possible in the XIR3. The receiver is located in the bottom left corner of the appliance. IM, 15 If receiver removal is necessary, remove the left access panel from the front of the appliance. Remove the 2 screws holding the receiver in place. Pull the receiver through the access hole and replace. e 0 • o • e o RECEIVER PLATE SCREWS � 4 - 0 W415-1343 / A / 11. 18.16 16 5.0 ELECTRICAL INFORMATION WARNING DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT. RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS. ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN THE UNITED STATES. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. 5.1 WIRING DIAGRAM V Ha F ss.2 2 This appliance comes equipped with a battery back-up. If this back-up is used, install 4 AA batteries (not supplied) into the receiver. W415-1343 / A / 11.18.16 17 6.0 OPERATION When lit for the first time, the appliance will emit a slight odour for a few hours. This is a normal temporary condition caused by the "burn -in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room. After extended periods of non- operation such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilate the room. 6.1 OPERATING AND LIGHTING INSTRUCTIONS OPERATING INSTRUCTIONS / INSTRUCTIONS D'OPERATION FOR YOUR SAFETY READ BEFORE OPERATING / POUR VOTRE SECURITE LIRE AVANT DE FAIRE FONCTIONNER WARNING: DO NOT TURN ON IF CHILDREN OR OTHER AT RISK INDIVIDUALS ARE NEAR THE APPLIANCE. IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INITIAL LIGHTING OF THE PILOT AND MAIN BURNERS MUST BE DONE WITH THE GLASS DOOR OFF. DO NOT CONNECT VALVE OR WALL SWITCH TO ELECTRICITY. SEE INSTALLATION INSTRUCTIONS. A THIS APPLIANCE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT BY HAND. 8. BEFORE OPERATING, SMELL ALL AROUND THE APPLIANCE AREA FOR GAS AND NEXT TO TME FLOOR BECAUSE SOME GAS IS HEAVIER THAN MR AND WILL SETTLE ON THE FLOOR. WHAT TO DO IF YOU SMELL GAS: • TURN OFF ALL GAS TO THE APPLIANCE. •OPEN WINDOWS. • DO NOT TRY TO LIGHT ANY APPLIANCE. • DO NOT TOUCH ANY ELECTRICAL SWITCH: DO NOT USE ANY PHONE IN YOUR BUILDING. • IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOUR'S PHONE. FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS. • IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT. C. DO NOT TRY TO REPAIR ANY PART OF THIS ASSEMBLY. CALL A QUALIFIED SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY RESULT INA FIRE OR EXPLOSION. D. DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDERWATER. IMMEDIATELY CALLA QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER. ATTENTION: NE PAS ALLUMER SI DES ENFANTS OU 1) AUTRES INDIVIDUS A RISQUE SONT A PROXIMITE DU FOYER. QUICONQUE NE RESPECTE PAS A LA LETTRE LES INSTRUCTIONS DANS LA PRESENTE NOTICE, RISQUE DE DECLENCHER UN INCENDIE OU UN EXPLOSION ENTRAINANT DES DOMMAGES, DES BLESSURES OU LA MORT. L'ALLUMAGE INITIAL DE LA VEILLEUSE ET DU BROLEUR PRINCIPAL DOIT SE FAIRE AVEC LA PORTE VITREE ENLEVEE. NE RACCORDEZ PAS LA SOUPAPE OU L'INTERRUPTEUR MURAL A ULECTRICITE. CONSULTEZ LES INSTRUCTIONS D'INSTALLATION. 0. CET APPARET EST MUNI DUN DISPOSITIF 0 ALLUMAGE 00 ALLUME AUTOMATIQUEMENT LA VEILLEUSE. HE TENTEZ PAS D'ALLUMER LA VEILLEUSE MANUELLEMENT. B, AVANT DE FAIRE FONCTIONNER, RENIFLEZ TOUT AUTOUR DE L'APPAREIL POUR DECELER UN ODEUR DE GAZ. RENIFLEZ PRES DO PLANCHER. CAR CERTAINS GAZ SONT PLUS LOURDS QUE UMR ET PEUVENT S'ACCUMULER AD NNEAU DU SOL. QUE FAIRE SI VOUS DETECTEZ UNE ODEUR DE GAZ: COUPEZ L'AMMENTATION DE GAZ PRINCIPALS • OUVREZ LES FENETRES. • HE PAS TENTER D'ALLUMER U'APPAREIL. HE TOUCHEZ AAUCUN INTERRUPTEUR, NE PAS VOUS SERNR DES TELEPHONES SE TROUVANT DANS LE BATIMENT. • APPELEZ IMMEDIATEMENT VOTRE FOURNISSEUR DE GAZ DEPUIS UN VOISIN. SUIVEZ LES INSTRUCTIONS DO FOURNISSEUR. • SI VOUS NE POUVEZ REJOINDRE LE FOURNISSEUR APPELEZ LE SERVICE DES INCENDIES. C. N'ESSAYEZ PAS DE REPARER AUCUNE PIECE DE CET ASSEMBLAGE. APPELEZ UN TECHNICIEN QUAUFIL FORCER OU TENTER DE REPARER LASSEMBLAGE POURRAIT CAUSER UN FEU OU UNE EXPLOSION. D. N'UTILISEZ PAS CET APPAREIL S'IL A ETE PLONGE DANS L'EAU, MEME PARTIELLEMENT FA TES INSPECTER L'APPAREIL PAR UN TECHNICIEN QUALIFIE ET REMPLACEZ TOUTE PARTIE DO SYSTEM DE CONTROLE ET TOUTE COMMANDE QUI ONT ETE PLONGES DANS LEAD. W38SQa601E LIGHTING INSTRUCTIONS / INSTRUCTIONS D'ALLUNIAGE 1. STOP READ ALL INFORMATION OF OPERATING AND LIGHTING INSTRUCTIONS BEFORE PROCEEDING. 2.TURN OFF ELECTRICAL POWER TO THE APPLIANCE. 3. THIS APPLIANCE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND. 4. OPEN THE GLASS DOOR. S. TURN MANUAL SHUTOFF VALVE CLOCKWISE /—A TO OFF. 6. WAIT FIVE (5) MINUTES TO CLEAR OUTANY GAS. IF YOU SMELL GAS, INCLUDING NEAR THE FLOOR, STOP[ FOLLOW "B" OF THE OPERATING INSTRUCTIONS. IF YOU DONT SMELL GAS, GO TO THE NEXT STEP. 7.TURN MANUAL SHUTOFF VALVE COUNTER -CLOCKWISE *�1 TO ON. 8.CLOSE THE GLASS DOOR. 9. TURN ON ALL ELECTRICAL POWER TO THE APPLIANCE. 10. TURN ON MAIN BURNER. D oyp10��\� � ass 1. ARRETEZI LISEZ TOUTES LES INSTRUCTIONS DE FONCTIONNEMENT ET D'ALLUMAGE AVANT DE CONTINUER. 2. COUPEZ UALIMENTATION ELECTRIQUE A UAPPAREIL. 3. CETAPPAREIL EST MUNI D'UN DISPOSITIF D'ALLUMAGE QUI ALLUME LA VEILLEUSE AUTOMATIQUEMENT, N'ESSAYEZ PAS D'ALLUMER LA VEILLEUSE MANUELLEMENT. 4. OUVREZ LA PORTE VITREE. 5. TOURNEZ LA SOUPAPE DE SECTIONNEMENT MANUELLE VERS LA DROITE /---A A a OFF.. S. ATTENDEZ CINQ (5) MINUTES POUR QUE LE GAZ PUISSE S'ECHAPPER. SI VOUS DETECTEZ UNE ODEUR DE GAZ, ARRETEZI SUIVEZ a B s DANS LES INSTRUCTIONS DE FONCTIONNEMENT. S'IL NY A PAS D'ODEUR DE GAZ, PASSEZ A L'ETAPE SUIVANTE. 7. TOURNEZ LA SOUPAPE DE SECTIONNEMENT MANUELLE VERS LA GAUCHE ',--\A. ON ». 8. FERMEZ LA PORTE VITREE. 9. RETABLISSEZ L'ALIMENTATION ELECTRIQUE AU FOYER, 10. ALLUMEZ LE BROLEUR PRINCIPAL. TO TURN OFF GAS / INSTRUCTIONS POUR COUPER LE GAZ 1. TURN OFF ALL ELECTRICAL POWER TO THE APPLIANCE IF SERVICE IS 1. COUPEZ UAUMENTATION ELECTRIQUE AU FOYER SI UN TRAVAIL TO BE PERFORMED. D'ENTRETIEN DOIT SE FAIRE. 2. TURN MANUAL SHUTOFF VALVE CLOCKWISE /-'1 TO OFF. DO NOT 2. TOURNEZ LA SOUPAPE D'ARRET MANUELLE VERS LA DROITE /—�1 FORCE. A,, OFF,,. NE FORCEZ PAS. _ W385-0460 / E W415-1343 / A / 11.18.16 W 6.2 XIR3 OPERATION t IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED. 6.2.1 GENERAL TRANSMITTER LAYOUT TRANSMISSION HILD SAFETY OCK OUT ` ROOM 8 TEMPERATURE �--yoF� LOW BATTERY �� 760 J ALARM 108 TEMPERATURE SET POINTI LEVEU STATUS FLAME FAN AUX. OUTPUT SPLIT VALVE 6.2.2 APPLIANCE OPERATION A. Install 4 AA batteries into the receiver battery bay as indicated on the battery cover (+/-). (Only required as back up to household electricity). B. Place the 3 position slider switch of the receiver in the "Remote" position. C. Using the end of a paper clip, or other similar object, insert the end of the paper clip into the hole marked "PRG" on the receiver front cover. The receiver will "beep" three (3) times to indicate that it is ready to synchronize with the transmitter. D. Install the 3 AAA batteries in the transmitter battery bay, located on the base of the transmitter. With the batteries already installed in the transmitter, push the "ON" button. The receiver will "beep" four times to indicate the transmitter's command is accepted and set to the particular code of that transmitter. The system is now initialized. 35.2A 6.2.3 HAND HELD REMOTE OPERATIONS A. Press the ON/OFF key on the transmitter. The transmitter display will show all active icons on the screen. A single "beep" from the receiver will confirm reception of the command. W415-1343 / A / 11. 18.16 BLUE LCD DISPLAY ON/OFF KEY TEMPERATURE KEY UP/DOWN ARROW KEY MODE KEY 35.4A 6.2.4 TEMPERATURE DISPLAY A. With the system in the "OFF" position, press the Temperature Key and the Mode Key at the same time to change from degrees F to C. B. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display. 6.2.5 ROOM THERMOSTAT The remote transmitter can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in the room. 7 3 [1ftE] A. Press the Thermostat Key. The LCD display on the Transmitter will show that the room is "ON" and the set temperature is now displayed. B. To adjust the set temperature, press the Up/Down Arrow Keys until the desired set temperature is displayed on the SET TER LCD screen of the Transmitter. 6.2.6 SMART THERMOSTAT The Smart Thermostat function adjusts the flame height according to the difference between the set temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will automatically adjust the flame down. A. Press the thermostat key until the word "SMART" appears to the right of the temperature bulb graphic. B. To adjust the set temperature, press the Up/Down arrow keys until the desired set temperature is displayed on the LCD screen at the Transmitter. 6.2.7 FLAME HEIGHT The remote control has six (6) flame levels. With the system on and the flame level at the maximum, press the Down Arrow Key once and it will reduce the flame height by one step until the flame is turned off. The Up Arrow Key will increase the flame height each time it is pressed. If the Up Arrow Key is pressed while the system is on but the flame is off, the flame will come on the high position. A single "beep" will confirm reception of the command. 76Q OFF 14 FLAME OFF 76ft FLAME AT LEVEL 5 19 23Fc 35.5A ROOM TEMPERATURE 6 °F 1Q -6 RATURE 35.6 t 11M 35.7 7616 68 76: 76*fl H i W415-1343 / A / 11.18.16 20 6.2.8 CHILD PROOF FUNCTION This function will lock the keys to avoid unsupervised operation. A. Press the MODE and UP keys at the same time. B. To de -activate this function, press the MODE and UP keys at the same time. 6.2.9 NIGHT LIGHT The auxiliary function controls the AUX power outlet on the Control Module which controls the NIGHT LIGHT TM A. Use the Mode Key to guide you to the AUX icon. B. Pressing the Up Arrow Key will activate the NIGHT LIGHTTM. C. Pressing the Down Arrow Key will turn the NIGHT LIGHT TM off A single "beep" will confirm 35.10A the reception of the command. 35.12A 6.2.10 LOW BATTERY / MANUAL BYPASS The life span of the remote batteries depends on various factors: quality of the batteries, the number of ignitions, etc. When the transmitter batteries are low, a battery icon will appear on the LCD display before all battery power is lost. When the batteries are replaced, this icon will disappear. When the receiver batteries are low, no "beep" will be emitted from the receiver when it receives an ON/OFF command. This is an alert for the receiver that there's low battery. When the batteries are replaced, the "beep" will be emitted from the receiver when the ON/OFF key is pressed. ® 761ft 76e \W4 Ed 7616 If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the three position slider switch on the receiver to the "ON" position. This will bypass the remote control feature and the appliance main burner will come on if the gas valve is in the "ON" position. 35.13A 6.2.11 IN THE EVENT OF A POWER FAILURE If the receiver is equipped with batteries they will enable flame height control or ON/OFF function to control the fireplace during a power failure. Refer to "APPLIANCE OPERATION" section when communications between receiver and transmitter have been lost. The receiver will emit a "beep" sound to confirm programming has been successful once power is restored. During a power failure, if the fireplace was on, the flame height will stay at the setting prior to the failure. If off when the failure occurs and then turned on, the flame height will come on at "HI". The flame height can then be controlled by the remote. 35.14A 6.2.12 CONTROL MODULE The control module offers a remotely actuated 120V AUX outlet for the accent lights and a constantly powered 120V outlet. NOTE: Control module ON/OFF switch should always be in the "ON" position. If for any reason the module is turned "OFF", the components plugged into the module won't have power. W415-1343 / A / 11.18.16 MAINS VOLTAGE ® SUPPLY CORD MODULE ON/OFF D Q SWITCH (SHOWN IN THE ON POSITION) COMMUNICATION 120V AUX OUTLET BUS (3 PIN) CONSTANTLY POWERED 120V OUTLET 35.16 6.2.13 SPLIT FLOW VALVE The split flow function controls the ability to turn ON/ OFF a second burner. A. B. C Use the mode key to guide you to the split flow function. Pressing the up arrow key will activate the second burner. messing the clown arrow Key will deactivate the second burner. A single "beep" will confirm the reception of the command. NOTE: There is no way to modulate the flame heights separately. 6.2.14 TIMED BLOWER 21 35.17A Your remote system may have a built in timer (in thermostat mode) that enables the blower (if equipped) to cycle on and off automatically when the burner turns on and off. With the remote control fan speed preset at the preferred speed, the blower will come on approximately 5 minutes after the main burner comes on and will shut off approximately 12 minutes after the burner shuts off. This time delay is designed to maximize the blower distribution of heated air. If at any time the burner re -ignites before the twelve minutes are over, the fan will continue to run. NOTE: At any time in the sequence, the blower (if equipped) can be manually turned on/off using the remote control. 35.198 6.3 ANTI CONDENSATION CONTROL SWITCH This appliance has the option to go from an electronic intermittent RIGHT SIDE OF pilot ignition to a standing pilot for cold climates. DOOR FRAME (OPERATING SIDE) ANTI CONDENSATION CONTROL SWITCH W415-1343/ A/ 11.18.16 22 7.0 ADJUSTMENTS 7.1 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read as described on the chart below. Check pressure with main burner operating on "HI". Outlet pressure can be checked the same as above using screw (B). Gauge should read as described on the chart below. Check pressure with main burner operating on "HI". AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution. Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a synthetic scrub pad (such as Scotch-Brite TM) can be used to remove the paint from the pilot hood, electrode and flame sensor. PILOT SCREW ELECTRODE PILOT \ BURNER 3/8" - 1/2" (9.5mm - 12.7mm) FLAME SENSOR FLAME MUST ENVELOP UPPER 318" (9.5mm) TO 112" (12.7mm) OF FLAME SENSOR Pressure Natural Gas Natural Gas Propane Propane (inches) (millibars) (inches) (millibars) Inlet '7" 17.4mb 13" 32.4mb (MIN.4.5') (MIN.11.2mb) (MIN.11") (MIN.27.4mb) Outlet 3.5" 8.7mb 10" 24.9mb *Maximum inlet pressure not to exceeed 13". 7.2 VENTURI ADJUSTMENT 39.1 E This appliance has an air shutter that has been factory set open according to the chart below: VENTURI BURNER Regardless of venturi orientation, closing the air shutter will cause a more yellow flame, but can lead to carbonization. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. r5QJ AIR The flame may not appear yellow immediately; allow 15 to 30 minutes for/ SHUTTER the final flame colour to be established. LEOPENING AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED ORIFICE INSTALLER! 49.1 W415-1343 /A / 11.18.16 7.3 FLAME CHARACTERISTICS It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustration provided. If any flames appear abnormal, call a service person. 23 ELECTRODE PLOT BURNER 3/8" -1/2"— (9.5mm-12.7mm) FLAME SENSOR FLAME MUST ENVELOP T UPPER 318" (9.5mm) TO 112" (12.7mm) OF FLAME SENSOR 54.1 B W415-1343 / A / 11. 18.16 24 8.0 MAINTENANCE 8.1 This appliance and its venting system should be inspected before use and at least annually by a qualified service person. The following suggested checks should be performed by a qualified technician. The appliance area must be kept clear and free of combustible materials, gasoline or other flammable vapors and liquids. The flow of combustion and ventilation air must not be obstructed. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. A. In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to expose both assemblies. B. Keep the control compartment, media, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year. C. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly. D. Check to see that the pilot flame is large enough to engulf the flame sensor and/or thermocouple / thermopile as well as reaches the burner. E. Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carbon which can be distributed inside of firebox and on exterior surfaces surrounding vent termination. F. Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10 second total light -up period is satisfactory. Service as required. G. Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary. H. If for any reason the vent air intake system is disassembled, re -install and re -seal per the instructions provided for the initial installation. I. Cleaning the safety barrier may be necessary due to excessive lint / dust from carpeting, pets, etc. simply vacuum using the brush attachment. J. Ensure the relief system performs effectively. Check that the gasket is not worn or damaged. Replace if necessary. 40.1E ANNUAL MAINTENANCE . This appliance will require maintenance which should be planned on an annual basis. • Service should include cleaning, battery replacement, venting inspection and inspection of the burner, media and firebox. Refer to the door removal section and remove the door as instructed. • Carefully remove media if necessary (logs, glass, brick panels etc). • Using a vacuum with a soft brush attachment, gently remove any dirt, debris or carbon build up from the logs, firebox and burner. For glass media, follow the installation instructions for pre -cleaning. • Also gently remove any build-up on the pilot assembly including, if equipped; thermopile, thermocouple, flame sensor and igniter. NOTE: Clean flame sensor using a fine emery cloth or a synthetic scrub pad (such as Scotch-Brite TM) to remove any oxides. Clean the pilot assembly using a vacuum with a soft brush attachment. It is important that the pilot assembly is not painted. • Inspect all accessible gaskets and replace as required. • Access the blower, if equipped and clean using a soft brush and vacuum. • Re -assemble the various components in reverse order. W415-1343 / A / 11.18.16 25 Inspect the relief system. The appliance relieves through the main glass door or through the flaps on the firebox top. Ensure they open freely, and close sealed. Check the gas control valve pilot and Hi / Lo knobs move freely (if equipped) — replace if any stiffness in movement is experienced. Check for gas leaks on all gas connections up and downstream from the gas valve including the pilot tube connections. 37.1 E 8.2 CARE OF GLASS DO NOT CLEAN GLASS WHEN HOT! DO NOT USE ABRASIVE CLEANERS TO CLEAN GLASS. Buff lightly with a clean dry soft cloth. Clean both sides of the glass after the first 10 hours of operation with a recommended fireplace glass cleaner. Do not use an ammonia -based fireplace glass cleaner. Thereafter clean as required. If the glass is not kept clean permanent discoloration and / or blemishes may result. HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 5.1 A This appliance is factory equipped with 5mm ceramic glass. Use only replacement parts as supplied by the appliance manufacturer. DO NOT SUBSTITUTE MATERIALS. 5.5.1A 8.3 CARE OF PLATED PARTS If the appliance is equipped with plated parts, you must clean fingerprints or other marks from the plated surfaces before operating the appliance for the first time. Use a glass cleaner or vinegar and towel to clean. If not cleaned properly before operating for the first time, the marks can cause permanent blemishes on the plating. After the plating is cured, the fingerprints and oils will not affect the finish and little maintenance is required, just wipe clean as needed. Prolonged high temperature burning with the door ajar may cause discolouration on plated parts. NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be improved if the assembly is warmed, using a hair dryer or similar heat source. 6.1 8.4 DOOR GLASS REPLACEMENT Replacement glass/frame assembly shall be replaced as a complete unit as supplied by the appliance manufacturer. 56.1 C NOTE: Care must be taken when removing and disposing of any broken glass or damaged components. Be sure to vacuum up any broken glass from inside the appliance before operation. W415-1343 / A / 11. 18.16 26 Z 8.5 BURNER REMOVAL A. Remove the glass door, see "DOOR REMOVAL AND INSTALLATION" section. Remove the logs, see "FINISHING" section. B. Remove the 5 screws that secure the rear log support in place. Lift the support out. D. Remove the 5 screws that secure the front burner support in place and lift the support up and out. 8.6 FCM REPLACEMENT C. Remove the 4 screws holding the rear burner tube and lift it up and out. E. Remove the 4 screws that secure the front burner support in place and lift the burner up and out. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. THE APPLIANCE MAY BE HOT. DO NOT SERVICE APPLIANCE UNTIL IT HAS COOLED. A. To access the fan control module, you must first pull out MUM DDDIDIDO DIOOIODO the appliance, allowing enough room to access the left access plate. B. Remove the screws holding the access plate in position. o0010D000 DIODIIII C. Unplug the fan control module from the junction box. Unplug the night light plug and o. ACCESS PLATE blower plug (if applicable) from the fan control module. �® D. Remove the 2 screws securing the fan control to the access plate and replace. NOTE: Ensure that the Ol OFF switch is in the ON (-) position. E. Reinstall the plugs and access plate ON/OFF DDODDIDIIIOD0000 ❑ SWITCH W415-1343 / A / 11.18.16 27 8.7 NIGHT LIGHTTm REPLACEMENT Your appliance comes equipped with our "Night LightTM". The light has been pre -wired and is controlled from the remote control. If the lamp or lens needs to be replaced, follow the instructions below. A. Unplug the fan control module from the junction box located behind the left access panel. B. Remove the four screws that secure the lens frame. This frame retains the glass lens. The lamp can now be accessed. NOTE: Do not handle the lamp (bulb) with bare fingers, protect with a clean dry cloth. The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as lamp and lens are special "high temperature" products. When re -installing, ensure integrity of gasket seal. THE FIREBOX MUST BE SEALED. Over -tightening the screws could break the lens. "Light Leakage" from the upper area may be observed. The holes in the lamp housing are necessary for ventilation and must not be covered. �. 8.8 VALVE TRAIN REPLACEMENT \ i GASKET LENS COLS FRAME 9 A. Remove the glass door. See "DOOR REMOVAL AND INSTALLATION" section. Remove the burners, see "BURNER REMOVAL" section. B. Remove the 14 screws holding the valve train in place. NOTE: A new gasket may be required when reinstalling the valve train assembly. Contact your local authorized dealer/distributor. C. Carefully lift the valve train assembly out far enough to access the manual shut off valve and turn to the off position. Disconnect the flex connector from the valve. You may now lift the valve train out of the appliance. W415-1343 / A / 11. 18.16 9.0 REPLACEMENTS FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. When ordering replacement parts always give the following information: • Model & Serial Number of appliance • Installation date of appliance • Part number • Description of part • Finish PARTS, PART NUMBERS AND AVAILABILITY ARE SUBJECT TO CHANGE WITHOUT NOTICE. PARTS IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN 2 TO 5 BUSINESS DAYS FOR MOST DELIVERY DESTINATIONS. PARTS NOT IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN A 2 TO 4 WEEK PERIOD, FOR MOST CASES. PARTS IDENTIFIED AS `SO' ARE SPECIAL ORDER AND CAN TAKE UP TO 90 DAYS FOR DELIVERY. 41.1C W415-1343 / A / 11.18.16 W_ cc W O T C) 0 W Q CC U) J J Q J F— C) W Q- 0- 0 - 0- 0 Z Q 2 2 W H Wel a W Y V W O E- cn W cn w U) W (n W cn W cn W J p(oU) m 2 0U)(n W Y J O Q Lu Cf) gzCO Z N g O � a z Y C/) M w O Z Z M _j Lu Z - U P p p H m m ir Q rx2U3:= UI-F- W �� Cf) F ~¢ j W W W W U w O Q wmcrC) o»¢v)a>o z W m= m W O a0 N CD Mr M r O r N N N r LO I� M B CD N O r— Z N9 Or O N9 I- O Cj N O O O Co O Co O N to O V O Z ammo>cn z N cn O w WO M��L—]20 z O r N M d Q 0 W Y p(oU) 0U)(n J O C N Z cc m ~ >w W O > m w wmcrC) z m m= U) Q O p w Z w U w ~x-icnoczF-mo af-=¢�mgw-i OCw Z ammo>cn N cn O m z O U Z W Q Q O=) Q O W W GC'3=oi-a00aC> ac uj LU W O N O N O (h O M 0 O r U) n 0 a 0 I� m M M CO r CO Z O O N O O CM O N �.. N CO O 0 C7 r O O O O O r O CO O r d z u: W c N co LO W I� co W415 -1343/A/11.18.16 all N 0 a W >MM cc LU 0 E a W415-1343 / A / 11. 18.16 c Y � W W W W W W W O cn cn cn cn cn cn cn � cn � L2 Leo00 � � J Y Y W H Y J w J w M a. w Z Z CL � d Za ng da MJ a a Y w Z Y U a U z JawaUQpE zm Q Z Q d J Q a a°C=Q a w w U m ❑ Z Z ZQ J �U) m T) mc_n°C 0 Q _..1 W Ln J f- H J > w J 0QO �ao�t7� OZF' O_oOUw�czi�czl�czn a LU t7F-0U ZO n.ww 0 > w w Q W -j U- W ZG W cr❑ p U- U J J W O 0 F -C7 p �_w�_ www >>Z (U/}�QOw❑❑❑ 0 U w < g C�fr=== w w W J _ X000 W JJ WW J GMC79 f� O C7M.M LO M qooa LOO Ld0 co LD LD 99 0 CJ9M a0 0 O 0 O 0 d 09 d 0 d 0 O 0 O 0 O 0 O 0 Lo f- LO fl- M to LO U') M Ln M -999999- d 0 V d 0 d It d a M LO M m M LO M� ('� m LO a LL W dLO CO t` 00 00 p LC LU m T N M d t2 (2 M S N 0 W Y � W W W W W W W cnrrrr rrr L2 Leo00 � � J W M a. w Z Z CL � d da MJ a a Y w Z Y U JawaUQpE zm Z Q d J Q a m Y U w w Z Z ZQ J c m T) o 0 Q _..1 W f- o J w ZoC)MQ �ao�t7� O_oOUw�czi�czl�czn Cr- 0 J W p d_0_0U5UC7C7C7 W cr❑ J J J w❑ p�a: 0 �U)aF- www (U/}�QOw❑❑❑ riLL ri W 0JQ000000 w w W J J J W JJ WW J f� O (COO LO M d LOO Ld0 co LD LD 99 0 O 0 a0 0 O 0 O 0 d 09 d 0 d 0 O 0 O 0 O 0 O 0 Lo f- LO fl- M to LO U') M Ln M a LL W dLO CO t` co m p 00 LU N a z Q cc H w J M oi c _ M co O CBD LO N 0 N Wei r r r r r r r • O T T r W Q U) D J J W LU a a. z Q W H 31 0 W Y W Y U) O U) U) v)cncn w w m Cl) mmm co z LU d 0 y J a (L L N ZM d m JZ } LO U � wfn Z r- F- —�*� m w F- W Q J > ¢ O a u ti U m> CO a F- LL LL. mem 0cc0W}Z U rr N m w w�� w0mUJ—lz U) CO W OM o 2 (� xF-ZZ m W W Z 2 Z F-jZ.wjUW Z Z PmF-M a.wmZ) W 0 OD LL, CC wQ 00�� w Z pCzwm 93MMmmcom2>0cnw� mem �mF V¢C7m cncc m � NOzm-Z ¢wMp�0O0 pcza: cc W m Z jC)::) Comm wmwOaaa N N N O O (n O 00 M O U) NO M Itt O co ct O w to (O to LO 00 O O O r (0 O t- T r O O M F. LOLO O O O L6 LO O O to � O a�NI�N0N(i°O�N� N M Lo O co N M M ft M O (0 NC) O O O O O O O _ O O M r N r T p F- 1 m z������ i (O (D (O i (6 i O i O O i O a r o d d 0 _O 0 0 0 3: 3 ti c0 M N N N N 0 W Y U) w w w w w w w z 0 a ZM d � } LO U � Z Y —�*� m w w U u w w U U < U ti U a: Ir Hw— cnm mem 0cc0W}Z C7 Z¢0 w0mUJ—lz OM Z 0 O m W W Z 2 Z U Z Y PmF-M a.wmZ) w 0 z xzx<Cw�U mmmmwo< w Z pCzwm mem �mF V¢C7m cncc m � NOzm-Z ¢wMp�0O0 pcza: F -F- m Z jC)::) Comm wmwOaaa a mm w w C9 U) 00 MU') U-) (o (n M d' O 0LO to M 00 N M Lo O co N M M ft M O (0 NC) O O O O O O O T T O M r N r T p F- 1 m 1 O i (O (D (O i (6 i O i O O i O a r o d d 0 _O 0 0 0 3: 3 LC W N M--zr Lo (O ti 00 0) r W415-1343 / A / 11. 18.16 32 m w N co a 0 O G0 W cr 11 W415-1343/ A/ 11.18.16 V In 0 W Y O UJ cn (A cn c4 J CD W Cl) W Z X f- C J (-I c/ z Lu C) LLJ a - LL g W a U 0 OC F- tlC 20 vVj0=> Q C/) C a20U w w U cc w CD "T CO T O CO O O z � ch C 0 O O 9O O N O- O TO CJ O O O O a zCIJce) C) 0 z u: w r N M 't Ln V+ W 0 w V V Q O O J :m IW w � J 00 m w U) wQ Q cc LU � J m mi z w w OC U U) Q 0 w Q cr VJrr�^ J J J H ¢U X w cr a LU CL CL a z U) w H 33 a W Y U O w U) >- 2 <06 LL C 0 0 M M a0 Z Z -j O O U cr cr � cr- (1) > cl) U) w w O cc w w a a o 0 VowCw7 yocaar og�g LO F -am Lo LO GQ. W M ft W m ti co M 0 Y OU) W cn W CO W to w cn W o cr o LU LL o a cg Q LL z U) o m w� cr0 Qo 0 U W Z a ¢°COa0 CO Z}'O�cr- LIJ CC cc Z 0VONccr W a s U)Z D w ag z 0 d W W R CC J H w¢ O 0 cc d 2 O(n02dU 1 N Ir W Cf) co � O LL M a tto LO M 00 N 0 W M w 4. M M M U 22 LU CC r N co t.f) 0 W415-1343 / A / 11. 18.16 34 N a_ N W_ FE O N co W U Q M� T ' L W415-1343 / A / 11. 18.16 r - U) Lo co co 0 W Q U) J J CO J U¢ X W cc W CL Q T m 0 O (7 z Q G T W c W Y v~i } CD M ti cc7 U) CD 47 M 0(n v EDMZ0(ntiM cn � �m ZC7fnrnMZ ==ZmW =ZMto- �Z (0 _ m Mp Sgz Z:5 m m CF - Z gZZ=g5 �U)_� cpm zo _ �g="°L �o cn oJgggggg � m ok= �oui CC J m Y a J ri oC CMD _ z w OCpp�w Ol- W OOpw0Ou�QO COmrC)F - O mmI-0 O� W M COZ:M rn O CO O 07 O In N tt N M O r to N O 0 y� 0 N 0 0 0 r 0 N 0 0 0 M CD E.. M M N cM CO N CO N ML� N to Y m ft N N t- 0 LC W IWE .- N M ''t Lo 0 I-- w T C Y v~i } CD M ti N CD M 0(n iF— EDMZ0(ntiM cn � �m ZMtn ==ZmW M0 (0 Mp �C9"Z m C3 - Z gZZ=g5 ZZ= cn oJgggggg �oui � U J H CLWcr00LU J~ CL z CL LuoapwpOOpwp OmHUF- COmrC)F - M O� W M rn rn O ao r 0 r 0 0 T 0 r 0 T 0 r 0 r 0 0 f. M w M CD M w m CD M w M co m Cfl M CD M CD ft LC W m .- N M ''t Lo 0 I-- w T 35 11.0 TROUBLESHOOTING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. SYMPTOM PROBLEM TEST SOLUTION Remote controls Remote is locked out. - Reset by turning power source off then on. Crystalite / Night NOTE: If back up batteries are installed, they light but no spark or must also be removed to re -program. flame. (millibars) Main burner flame Blockage in vent. - Remove blockage. In really cold conditions, ice is a blue, lazy, buildup may occur on the terminal and should transparent flame. be removed as required. To minimize this from 32.4mb happening again, it is recommended that the vent (MIN. 4.5") lengths that pass through unheated spaces (attics, (MIN. 11") garages, crawl spaces) be wrapped with an insulated Outlet mylar sleeve. Prevent sleeve from sagging. Contact 8.7mb your local authorized dealer for more information. Flames are consistently too large or too small. C; occurs. Appliance is over -fired or - underfired. *Maximum inlet pressure not to exceed 13" Check pressure readings: Inlet pressure can be checked by turning screw (A) counter -clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read as described on the chart below. Check that main burner is operating on 'HI'. Outlet pressure can be checked the same as above using screw (B). Gauge should read as described on the chart below. Check that main burner is operating on 'HI'. AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVER TORQUE. Leak test with a soap and water solution. Pressure Natural Gas Natural Gas Propane Propane obstructions. (inches) (millibars) (inches) (millibars) Inlet *7 17.4mb 13" 32.4mb surfaces. (MIN. 4.5") (MIN.11.2mb) (MIN. 11") (MIN.27.4mb) Outlet 3.5" 8.7mb 10" 24.9mb Carbon is being Air shutter has become - Ensure air shutter opening is free of lint or other deposited on blocked. obstructions. glass, logs, rocks, media Flame is impinging on - Check that the glass, logs, rocks, media are correctly or combustion the glass, logs, rocks, positioned. chamber media or combustion - Open air shutter to increase the primary air. surfaces. chamber. - Check the input rate: check the manifold pressure and orifice size as specified by the rating plate. - Check that the door gasketing is not broken or missing and that the seal is tight. - Check that both vent liners are free of holes and well sealed at all joints. - Check that minimum rise per foot (meters) has been adhered to for any horizontal venting. W415-1343 / A / 11.18.16 36 White / grey film Sulphur from fuel is being - Clean the glass with a recommended gas fireplace forms. deposited on glass, logs glass cleaner. DO NOT CLEAN GLASS WHEN HOT. or combustion chamber - If deposits are not cleaned off regularly, the glass surfaces. may become permanently marked. 42.1 D SYMPTOM PROBLEM TEST SOLUTION Exhaust fumes Appliance is spilling. - Check door seal. smelled in room, connection. - Check for exhaust damage. headaches. - Check that venting is installed correctly. at pilot burner. - Room is in negative pressure; increase fresh air supply. Pilot will not light. Wiring. - Verify the wire for the sensor and the wire for the Makes noise with grounded. ignitor are connected to the correct terminals (not no spark at pilot Ignition box has been reverse) on the module and pilot assembly. burner. Loose connection. - Verify no loose connections, electrical shorts in the wiring or ground out to any metal object. Igniter Spark gap is - Spark gap of the ignitor to the pilot should be .125" incorrect. (3.2mm). Pilot will not light. A shorted or loose - Remove and reinstall the wiring harness that plugs into Makes no noise connection. the module. with no spark - Remove and verify continuity of each wire in the wiring at pilot burner. harness. CrystalitesTm and (optional) blower Module is not - Verify the valve and pilot assemblies are properly operates. grounded. grounded to the metal chassis of the fireplace. Ignition box has been Choose one of the 4 methods below to reset the system. locked out. 1. To reset ignition box when locked out. Turn off power supply and remove batteries (if used) from the back up battery pack. 2. To reset the DFC Board when the board goes into a lock out condition and the LED is blinking 3 times using the transmitter ON/OFF button: Step 1: Turn the system off by pressing the ON/ OFF button to turn the system off. Step 2: After approximately 2 seconds press the ON/OFF button on the transmitter again. THE DFC Board will reset and the ignition sequence will start again. 3. To reset the DFC Board when the board goes into a lock out condition and the LED is blinking 3 times by cycling flame: Step 1: In the manual flame control mode, use the down arrow button to reduce the flame to off, indicated by the word OFF displayed on the trasmitter LCD screen. Step 2: Wait approximately 2 seconds and press the up arrow button, the ignition sequence will start. NOTE: Starting from OFF, press the ON button on the transmitter. Approximately 4 seconds after the ON/OFF button is pressed the ignition board will start the spark. The first try for ignition will last approximately 60 seconds. ff there is no flame ignition (rectification) the board will stop sparking for approximately 35 seconds. After the wait time the board will start the second try for ignition by sparking for approximately 60 seconds. ff there is still no positive ignition, the board will go into lock out. 42.1_2A W415-1343 / A / 11. 18.16 SYMPTOM PROBLEM TEST SOLUTION 37 Pilot sparks but Gas supply. - Verify that the incoming gas line ball valve is "Open". will not light. - Verify that the inlet pressure reading is within sensor rod. acceptable limits, inlet pressures must not exceed Appliance won't 13" W.C. (34.9mb). Module is not grounded. - Verify the value and pilot assemblies are properly wrong position. grounded to the metal chassis of the fireplace. Out of propane gas. - Fill the tank. Continues to Short or loose connection Verify all connections. Verify the connections spark and pilot in sensor rod. from the pilot assembly are tight; also verify these lights, but main connections are not grounding out to any metal. burner will not light. Poor flame rectification or - Verify the flame is engulfing the sensor rod. This contaminated sensor rod. will increase the flame rectification. Verify correct Night light or pilot orifice is installed and inlet gas specifications - Verify ON/OFF switch is in the "I" position which to manual. (Remember, the flame carries the in the wrong position. rectification current, not the gas. If the flame lifts won't function from pilot hood, the circuit is broken. A wrong orifice - Verify "COM" switch is plugged into the front of the or too high of an inlet pressure can cause the pilot unplugged. flame to lift.) The sensor rod may need cleaning. Poor grounding between pilot assembly and gas valve. - Verify that the wire harness is firmly connected to module. Damaged pilot or dirty - Verify that the ceramic insulator around the sensor sensor rod. rod is not cracked, damaged, or loose. Verify the Appliance won't connection from the sensor rod to the sensor - Verify that the 3 position switch on the receiver is in wire. Clean sensor rod with a green Scotch-Brite wrong position. pad to remove any contamination that may have functions. accumulated on the sensor rod. Verify continuity with multimeter with ohms set at the lowest range. 42.1_3B W415-1343 / A / 11. 18.16 Pilot has been painted - Using a scrub pad, remove the paint from the pilot hood, ignitor and flame sensor. Appliance won't Receiver switch is in the - Verify that the 3 position switch on the receiver is in perform any wrong position. the "REMOTE" position (middle). functions. No power to the system. - Check breaker to verify it's in the "ON" position. Transmitter isn't - Check battery power and battery orientation. operational. Night light or Control module switch is - Verify ON/OFF switch is in the "I" position which (optional) blower in the wrong position. denotes on. won't function COM switch is - Verify "COM" switch is plugged into the front of the unplugged. control module. 42.1_3B W415-1343 / A / 11. 18.16 38 12.0 WARRANTY NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test -fired at a quality test station. The complete appliance is again thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON. NAPOLEON GAS APPLIANCE PRESIDENT'S LIFETIME LIMITED WARRANTY The following materials and workmanship in your new NAPOLEON gas appliance are warranted against defects for as long as you own the appliance. This covers: combustion chamber, heat exchanger, stainless steel burner, PhazerTM logs and embers, rocks, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enameled components and aluminum extrusion trims.' Electrical (110V and millivolt) components and wearable parts are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty. This covers: blowers, gas valves, thermal switches, switches, wiring, remote controls, ignitors, gaskets and pilot assemblies." Labour related to warranty repair is covered free of charge during the first year. Repair work, however, requires the prior approval of an authorized company official. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer. Construction of models vary. Warranty applies only to components included with your specific appliance. NAPOLEON warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim. Provided that the purchase was made through an authorized NAPOLEON dealer your appliance is subject to the following conditions and limitations: Warranty coverage begins on the date of original installation. This factory warranty is non -transferable and may not be extended whatsoever by any of our representatives. The gas appliance must be installed by a licensed, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes. This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty. This limited warranty further does not cover any scratches, dents, corrosion or discoloring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZERTM logs and embers. This warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions. After the first year, with respect to this President's Lifetime Limited Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s). NAPOLEON will not be responsible for installation, labour or any other expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty. Notwithstanding any provisions contained in the President's Lifetime Limited Warranty, NAPOLEON'S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages. This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas appliance and any other warranties expressed or implied with respect to this product, its components or accessories are excluded. NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for: over -firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc. Any damages to the appliance, combustion chamber, heat exchanger, plated trim or other components due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON. All parts replaced under the President's Limited Lifetime Warranty Policy are subject to a single claim. During the first 10 years NAPOLEON will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON will provide replacement parts at 50% of the current retail price. All parts replaced under the warranty will be covered for a period of 90 days from the date of their installation. The manufacturer may require that defective parts or products be returned or that digital pictures be provided to support the claim. Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will repair or replace such defect. Before shipping your appliance or defective components, your dealer must obtain an authorization number. Any merchandise shipped without authorization will be refused and returned to sender. Shipping costs are not covered under this warranty. Additional service fees may apply if you are seeking warranty service from a dealer. Warranty labour allowance is only for the replacement of the warranted part. Travel, diagnostic tests, shipping and other related charges are not covered by this warranty. ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. 2.1 D W415-1343 / A / 11. 18.16 39 13.0 SERVICE HISTORY W415 -1343/A/11.18.16 ti N 7 C � fA c _°- a d � � 2, O � U r T � w � Q E Qa) f6 � N L N L F , , , W415 -1343/A/11.18.16 Me 14.0 NOTES "A W415-1343 / A / 11. 18.16 44.1 mm 24 Napoleon Road, Barrie, Ontario, Canada L4M OG8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky. USA 41030 7200 Trans Canada Highway, Montreal, Quebec, Canada H4T 1A3 Fireplaces / Heating & Cooling call: 705-721-1212 • Grills call: 705-726-4278 napoleonproducts.com i CITY OF WHEAT RIDGE 9 1Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: /Y1 t) Job Address: 31315 hti , c 5y Permit Number: ")Oi'?41,,r)-O ❑ No one available for inspection: Time I ?'_7" Re -Inspection required: Yes No) When corrections have been made, call for re -inspection at 303-234-5933 r Date:. Inspector:��'� DO NOT REMOVE THIS NOTICE 3132 G�4,,w I., INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Occupancy/Type Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Wall Sheathing Sewer Service Mid -Roof Plumbing Do Not Cover Underaround or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing :Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather � w , City of Wheat Ridge s Residential Roofing PERMIT - 20170320 PERMIT NO: 201703250 ISSUED: 07/05/2017 JOB ADDRESS: 3137 Chase ST EXPIRES: 07/05/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey Legacy, Dimension asphalt shingles with ROOF DECKING - 14 sq. *** CONTACTS *** OWNER (720)255-4851 ABELL JOEL STEPHEN/SHANNON SUB (720)352-2916 Phil Crout 170290 PJC Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,691.75 FEES Total Valuation 0.00 Use Tax 98.53 Permit Fee 125.05 ** TOTAL ** 223.58 *** COMMENTS *** ** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to tinai approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spa -,ed or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. i CITY OF WHEAT RIDGE 9 1Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: /Y1 t) Job Address: 31315 hti , c 5y Permit Number: ")Oi'?41,,r)-O ❑ No one available for inspection: Time I ?'_7" Re -Inspection required: Yes No) When corrections have been made, call for re -inspection at 303-234-5933 r Date:. Inspector:��'� DO NOT REMOVE THIS NOTICE i CITY OFWHEAT AlDi�E Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: (2Joc Job Address: 3131? C VAI c � T Permit Number: 0017y�ZsO ❑ No one available for inspection: Time I V ', AJ �yPM Re -Inspection required: Y No When corrections have been made, call for re ecti n at 303-134-5933 Date: Z 9cllr� Inspector: 6�� DO NOT REMOVE THIS NOTICE City of Wheat Ridge r Residential Roofing PERMIT - 201703250 PERMIT NO: 201703250 ISSUED: 07/05/2017 JOB ADDRESS: 3137 Chase ST EXPIRES: 07/05/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey Legacy, Dimension asphalt shingles with ROOF DECKING - 14 sq. *** CONTACTS *** OWNER (720)255-4851 ABELL JOEL STEPHEN/SHANNON SUB (720)352-2916 Phil Crout 170290 PJC Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT4: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,691.75 FEES Total Valuation 0.00 PA k•' Use Tax 98.53 Permit Fee 125.05 - -' ** TOTAL ** 223.58^ ---- *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle, Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. ., � . 4 City of Wheat Ridge Residential Roofing PERMIT - 201703250 PERMIT NO: 201703250 ISSUED: 07/05/2017 JOB ADDRESS: 3137 Chase ST EXPIRES: 07/05/2018 JOB DESCRIPTION: Residential Re—roof to install Malarkey Legacy, Dimension asphalt shingles with ROOF DECKING — 14 sq. I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal o er of the property and authorized to obtain this permit and perform the work described and approved in conjunction with this permit. fu er atte g y authorized to include all entities named within this document as parties to the work to be performed to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature bf OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermitfee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. T 5. e permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required iM6ctions and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable or any ordinance or regulati n of this jurisdiction. Approval of work is subject to field inspection. �r�i><I.JYIm� Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Kimberly Cook Ub / ©S W v From: no-reply@ci.wheatridge.co.us Sent: Thursday, June 22, 2017 10:08 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 3137 Chase St. Joel Abell 7202554851 bornellous@msn.com I,✓lG voh/er Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. KCih;41-61Mi7:1TAI_N09]1 Contractor Name PjC Construction Contractor's License 170290 Number (for the City of Wheat Ridge) Contractor Phone 7203522916 Number Contractor Email Address loftusginal2@gmail.com Retype Contractor Email loftusginal2@gmail.com Address DESCRIPTION OF WORK Are you re -decking the Yes / roof? Description of Roofing MALARKEY LEGACY, DIMENSION Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 14 material selected above? Does any portion of the No / property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES of all 14 roofing material for this project z Provide additional detail n/a here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract -3-900— value or cost of ALL I materials and labor) 6 �J SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Phil Crout Email not displaying correctly? View it in your browser. 3 A+ Rating Pic CONS"!"RUCTION - HONESTY, INTEGIRITY & RELIABILITY ^ BBI Homeowner fvlobile-7�"5'?`- 9�1lome 3 13�-049 Email Date G-3-1-7 Propeny Address City Zip . . ....... . Approxi ate Date of Loss Damage resulting from wind. hail or other-_ am the owner of the above mentioned property ("Homeowner"), and I hereby authorize PJC Construction ("Contractor") to provide my restoration services in accordance with the terms and conditions set forth in this Agreement. It is estimated. based on the initial inspection, that my restoration services proposed by Contractor will cost approximately S ct Please note that this constitutes a rough estimate of my total job cost. The total cost of my job is subject to change, based on any supplemental claims made to my insurance company and/or adjustments made to my claim by my insurance company. Contractor can't assess the exact final amount that will he settled until my work has been completed. I'm aware that I am never responsible to pay any out-of-pocket expense other than my policy deductible. I understand that Contractor will utilize its insurance claim expertise in settling the amount of my claim with my insurance company. The payments that I will receive will reflect the amounts that Contractor has settled upon, and I will endorse and make payable to PJC Construction all payments that I receive for my claim, for work that is completed. If applicable, I understand that if my claim contains any amounts for Contractor "Overhead and Profit", these amounts will be paid to PJC Construction. Initial payment {"ACV") is due upon delivery of my materials, and the final payment ("Depreciation") is due within 3 days of my receipt. All original checks received from the insurance company shall be endorsed as follows: "Pay to the order of PJC Construction" followed by my signature. My deductible will be paid to PJC Construction, upon completion of my restoration work. I direct my insurance company to include PJC Construction on any and all of my checks or other instruments issued in payment of my claim. PJC Construction is also hereby authorized by me to discuss this specific claim and payments issued for it, on my behalf, with my insurance company and my mortgage company. Scope of work- PJC Construction will install all materials & complete all labor in accordance with the specifications outlined below, and the entire scope of the settled insurance claim will. be completed, unless otherwise stated. Shingle Year -1c, [v/Tear off all existing layers feean out all debris from gutters Install decking (7/16" OSB) move & haul away all debris from premises 14install new felt 5!,Ai,t, WI stall gutter& downspouts, -Color IdInstall eavefrake drip edge per code Color- lake a magnetic sweep of the yard and V'Install new pipe jacks & vents Aiveway areas to remove displaced nails i"kn'stall 6 nails per shingle ��4 Pull and post a city work permit 1-fRe-flashchimneys & headwall metals, as needed, per code [K5 year workmanship warranty Insurance company_ —Claim# Agent narnelphone# . . ........ Adjuster name/phone# — -Gij —tf U�,, i V/ Account # k1ortgage Company Aal,_1_1-*U ZMA W . . .... Approximate start date .-tVJft,1 Approximate completion date (.0 Additional terms or special instructions: P'( - -,it Pe dQjWu- -j tW)CIV Lgoir t>ee- Ctpsi ^-4 ThisAgreement is not valid if the insurance company does not agree to afull roof Date of Acceptance tP r Signature PJC Construction. Representative Signature 1633 Fillmore Street, Denver, CO 80206 - www.pjc-construction.net Phil: direct 720-352-2916, 1)hil;rli.,.pieconstructioii.net If Jake: direct 720-364-8365, jakeCd.Ricconstruction.net City of Wheat Ridge Residential Mechanic PERMIT - 201700641 PERMIT NO: 201700641 ISSUED: 05/09/2017 JOB ADDRESS: 3137 Chase ST EXPIRES: 05/09/2018 JOB DESCRIPTION: Install new 2.0 ton AC to existing furnace *** CONTACTS *** OWNER (720)209-9422 ABELL JOEL STEPHEN/SHANNON SUB (303)423-7905 Timothy Bartels 017674 B & B Heating & A/C *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,800.00 FEES Total Valuation 0.00 Use Tax 86.40 IL Permit Fee 125.05 ** TOTAL ** 211.45 Z'E1��1_}'}S) U *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. i, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include al I entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made -be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change. of the natural flow of water without prior and specific approval. 5. T44rpermit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuanc r granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicabl o or any ord"�:41 'on of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. �f 1 1 /i n1-)1n�I' G� INSPECTION RECORD AIC' IC' a.D'J}�;SPECTION REQUEST LINE: (303) 234-5933 Occupanc�ype Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Mid -Roof Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Initials Comments Electrical City of Wheat Ridne 05/09i'2017 :5: 3` CUBA Install new 2_0 ton CUH014E$5 A1,011 NT EPSP 3137 Chase ST ~11.45 APPL /PERMIT NO: 2@ 706641 PAYMEN I RECEIVE) AMOUNT +1S / 2640 ?11.45 AUTi CODE: 99995C TOTALi1>4=: ---------------------------------------- Inspections froi one week in ad%—.,--.. inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Sewer Service Plumbing Mid -Roof Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials City of Wheat Ridne 05/09i'2017 :5: 3` CUBA Install new 2_0 ton CUH014E$5 A1,011 NT EPSP 3137 Chase ST ~11.45 APPL /PERMIT NO: 2@ 706641 PAYMEN I RECEIVE) AMOUNT +1S / 2640 ?11.45 AUTi CODE: 99995C TOTALi1>4=: ---------------------------------------- Inspections froi one week in ad%—.,--.. inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Ins ections p Date Inspector Initials Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. 'For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. "For Inspection Time Window — Please email insptimerequest@ci.wheatridge.co.us by 8:00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City cif Wheat !vidgc CUn1MUNl11` [�t�t,tc�r:titli Building & Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 - Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(aki wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: ; t Property Owner (please print): `} t \I 1 i i 1' ( Phone: Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: Ar_chitect/Enaineer• Architect/Engineer E-mail: Contractor: i 1 Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License Other City Licensed Sub: City License # /r Plumbing: W.R. City License # Phone: Phone: ) Other City Licensed Sub: City License # Mechanical: W.R. City License # k-oniptete all information on BOTH sides of' this form ❑ COMMERCIAL] RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) AfO*J C) I OIL Sq. Ft./LF Btu's .rl � C1 1 Gallons Amps Squares Other Project Value; (Contract value or the cost of all materials and labor included in the entire project) E' --- - -- -- -- ONl'NEWC'ONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances. rules of regulations of the City of Wheat Ridge or covenants, casements or restrictions of record; that all measurements shown and allegations made arc accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am tiro legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal o A ner of any entity included on this application to list that entity on this application. 1, the applicant for this building pcmiit application, warrant the truthfulness of the information provided on the application. CIRCLEO,1E: (ON:'VER) (C'ONTRAC'TOR) or (A('TIIORI%L•'DREPRESEN7,ITI4E) oj'(0#FAER) (C0A'7'RAC'7'0R) Electronic Signature (rirst and last name): ZONING COMMMENTS: Reviewer BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY DATE: OCCUPANCY CLASSIFICATION: Building Division Valuation: $ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033. (303-235-2855) Building Permit Number: 17829 Date: 1 0/4/2004 . Property Owner: JOEL AND SHANNON ABELL Property Address: 3137 CHASE ST Contractor License No. : 22118 Company: Karsten Electrical Services, LLC Phone: 720-255-4851 Phone: 278-4044 (OWNER)(CONTRACTOR) SI nder this p~ DATE ~ if. Total: $1,789.00 $82.16 $0.00 $21.47 $103.63 Valuation: Permit Fee: Pian Review Fee: Use Tax: Use: ~19W Description: SERVICE UPGRADE. DRYER CIRCUIT & RECEPTACLE BUILDING DEPARTMENT USE ONLY z~.JD'tom.l:llllllJ Approval: Zoning: IilUdi.,lrIfITimentlllJl Approval: PlIliIIIIIiVQrk.~nt$:. Approval: Occupancy: Walls: SIC: Sq. Fl.: Roof: Stories: Residential Units: Electrical License No : 22118 Company : Karsten Electrical Services, LLC Expiration Date: 2/28/2005 Approval: OK/KS Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the Stale of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with su essive pha e job. The issua ermit e approval 0 prov" n ebui ~_o.r ings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the Inance, law, rule or regulation. (1) (2) (3) Chief Buiiding Inspector Please si9n Terms and Conditions on reverse side of page. ~~,otl~1(Vl COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234~933 CITY OF WHEAT RIDGE 7600 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2866) APPLICATION Property Owner: ~ arlO- $-o.Ylr\l(\ ~~ \ Property Address: 3\?,:t O-U~L ~ V Contractor License No,: "i!C Cc5\4 2-z..' \ g- Company: ~~ 'E\u..~fu.\ ~"\ce..') .>.~' WHEA> "', ~ '" - ~ u m C'OLQR,..f:R Building Penn~ Number Date: Phone: '., '"t?c -";;l55 -Lt'6S \ Phone: -=t-;;lO-q"frl - Rd=\ OWNERICONlRACTOR StGNAlURE Of UNDERSTANDING AND AGREEMENT Construction Value:$ I if?A, ~ Permit Fee:$ Plan Review Fee:$ Use Tax'$ Total:$ (IJINNER)(CONTRACTOR): SlG Description: . ":::><.Nk.e... \.l?'jn>.1..... y. ~~ '-'<""Lv\\. l,_ O:.L<C.~~ . Sq. Ft. added ZONING CoMMENTS: Approval: Zoning: BUILDING DEPARTMENT USE ONLY SIC: Sq.Fl.: BuiLDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Dccupancy: Walls: Roof: Stories: Residential Units: Electrical License No: 'ECio'5\l.\ Company: ~kt~c<\ E . t' Dt~~S xplra Ion a e: Approval: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws ofthe state of Colorado and to the Zoning Regulations and Building Codes of Vllheat Ridge, Colorado or any other applicable ordinances of lheCity. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or ffsuspension or abandonment exceeds one (1) year, full fees shall be paid for a new pennit. (4) No work. of any manner shall be done that will change the natural flow of water causing a drainage probtem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on Inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. Chief Building Official COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 17689 Date: 9/13/2004 Property Owner: WYANE STEWART Property Address: 3137 CHASE ST Contraclor License No. : 22091 Company: One Way Roofing Phone: 831-4332 Phone: 805-0667 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED I{-Lf G,. t2/ co/J DATE /3.5y'{! f Total: $4,346.00 $144.70 $0.00 $52.15 $196,85 p.ox;> /f21J ,85' Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description : TEAR OFF ALL ROOFS, INSTALL DECING & 25 YEAR 3 TAB. 14 SQ. BUILDING DEPARTMENT USE ONLY Zoning <:;oniriients: Approval: Zoning: ~l!IICllng Comin~ Approval: Public::WOrks ComJ:!:Wlts: Approval: Occupancy: Walls: SIC: Roof: /)oCt/me"ls fro OflSite /O",/b" "m IIr" mall'''' 1t>ofi <7, 1t>of I. -/t:lCIu"",. sit 110 :! l1taterials It 11SJ1ec1i0" wlli II all he "'U"O III 'lVe hee" i c. $peeVY AlPO wi"d 10~e-seCQ"d Wi,,/l$lalied to meet --0lJC). lfUst---IBc (~ Stories: Residential Units: () Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheal Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (Al the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or If suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem (5) Contractor shall notify the Buiiding Inspector twenty-four (24) hours in advance for all inspections and shail receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of th code yo 'nance, law, rule or regulation o Please sign Terms and Conditions on reverse side of page. ~' WHE'r.p " / ~ 0 - ~ u ~ COLC*\",OC COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE. 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 . (303-235-2855) APPLICATION Building Permit Number: Date '1 ~ 13.:;f Property Owner: Property Address: Contractor License No.: Ij) 1'Vlvt'..- 5t?,:tJAj/T 11 ~ -/ C h~?e. Phone,?t? rr~ / ~ t/33 z- Company: O'Vc h!(\1{ KC{).{~"'~ Phone;;'o37"ob - P'1i1f' OWNER/CONTRACTOR SIGNATURE Of \JNOER$T ANDING AND AG~EEMENT j hereby certify that the setback distances proposed by. this permit application are accurate. and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants. easements or restrictions of record: that all mea5UrenleOts shown. and anegations made are accurate; that I have read and agree \0 abide by aU conditions printed on thi'S application and that I assume full responsibility for compliance with the Wheat Rtdge Building Code (U.B.C) and all other applicable Wheat Ridge Ordinanoes. for work under this permit. Construction V alue:$ 4-3l{~ ~ Permit Fee:$ Plan Review Fee:$ Use Tax'S; Total:$ (Cl'NhER)(CON'TRACTOR): SK3NeD DATE Description: -(eAt" I t.f. r7 () ~ IiIvl ~",,{!-~ f (_I ~ ~.v,"K"C, cJ.. ' E> Uo?i+-'r ;:l'rA h;;., ; N'7 ,() t <:l ~....,<. 'I ,.., -; (OWNER)(CONTRACTOR}:PRINTEO Sq. ft. adde<l BUILDING DEPARTMENT USE ONLY SIC: Sq.Fl.: "ONING COMUENTS: Approval: Zoning: BUILDING COMUENTS: Approval: PuBliC WORKS CoMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: {1) This permit was issued in accordance with !he pnwilliom lMllloo1ll in )OUT oppIic:alion and is subject to !he laws of !he State of CoIo<8do and to !he Zoning Regulations _ Building Codea of Wheal Ridge, C--.oo or any _ applicable ordinances 01 !he City. (2) This permit _ e>;>ire W (A) !he -" authoriZed is no. commenced wilhin sixty (60) days from issue date or (B) !he building authorized io suspended or.-Ior a period of 120 daya. (3) If IhI8 permit expires, a MW permit may be __lor a fee of onoH1aII!he amount ~ required. provided no change$ have been a will be _In!he original plana and opecII"__ and any suapension or _'dOh._d - nol.~"- (1) year. If changes have been or W suspenslon a abandoo ...-. ..oeeds one (1) _, 1uI1_ shall be paid lor a .- permil (4) No -" 01 any _ _ be done lhIIl will change !he nalunllllow of _ causing a drainage problem. (5) ~ _ notify !he Building Inapeclor _ty-lour (24) houn in advance for all inspections and shall receive written appn>'181 on inopec.tion card _ proooeding with successive phasM of !he job. (6) The iAuanc::e of . permit or the approval of drawings and specifications shall not be construed to be a permit for. nor an approval of, any violation 01 the provistons of the buUding codes or any other ordinance. law. rule or regulation. Chief Building OffICial COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 17689 Date: 9/13/2004 Property Owner: WYANE STEWART Property Address: 3137 CHASE ST Contractor License No. : 22091 Company: One Way Roofing Phone: 831-4332 Phone: 805-0667 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT (OWNER)(CONTRACTOR) SIGNED DATE Total: $4,346.00 $144.70 $0.00 $52.15 $196.85 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinance's, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description: TEAR OFF ALL ROOFS, INSTALL DECING & 25 YEAR TAMKO 3 TAB, 14 sa. HOUSE AND GARAGE ONLY. BUILDiNG DEPARTMENT USE ONLY ?oning c:oAlm'9nts: Approval: Zoning: Bu1)jJJilg Commenlq Approvai : !liblic Wor.K~mments: Approval: SIC: Sq. Ft.: Documents from thll manufacture,: shall ~ to ft I roof /nqwction which specify orrs.1J: r ~.,. L__ betrl installed to meet rooJ.rlg 1IIlZ."""" no... l'Be (90 110 MPH tlt~ wflld gust-- MPH Wfitfl i-.tmt). Occupancy: Wails: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approvai : Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card Defore proceediing with successive phases of the job. (6) The issu permit 1 of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the pr . I e b' g codes or any ot ordinance, law, rule or regulation. Chief Buiiding Inspector Please Si9n Terms and Conditions on reverse side of page.