Loading...
HomeMy WebLinkAbout3285 Chase Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: j r Job Address: Permit Number:` ❑ No one available for inspection:_ Time 1 AM/PM Re -Inspection required: Yes 'Nom When corrections have been made, call for re -inspection at 303-234-5933 r' Date:. ;' Inspector: DO NOT REMOVE THIS NOTICE W.1111111111PT I -q^rv% . e, INSPECTION RECORD INSPECTION REQUEST LINE: (303) 234-5933_ Occupancy/Type c' Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Wall Sheathing Foundation Inspections Date Inspector Comments Initials Fire Inspection / Fire Protection Dist. Pier Mid -Roof Concrete Encased Ground (CEG) Foundation / P.E. Letter Lath / Wall Tie Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Mid -Roof Final Plumbing Final Mechanical Roof Lath / Wall Tie Final Window/Doors Final Building Rough Electric NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. *"For Inspection Time Window — Please email insptimerequest@Ci.Wheatridge.Co.US by 8:00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather , 4 City of Wheat Ridge Residential Roofing PERMIT - 201701526 PERMIT NO: 201701526 ISSUED: 06/05/2017 JOB ADDRESS: 3285 Chase ST EXPIRES: 06/05/2018 JOB DESCRIPTION: Reroof with OC Dimensional shingles; ice & water, drop edge, felt - 16 squares *** CONTACTS *** OWNER (303)462-5936 LOOMIS LINDA C SUB (303)328-3713 John Duvall 130171 Duvall Construction Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,500.00 FEES Total Valuation 0.00 Use Tax 94.50 Permit Fee 125.05 ** TOTAL ** 219.55 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturerioms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201701526 PERMIT NO: 201701526 ISSUED: 06/05/2017 JOB ADDRESS: 3285 Chase ST EXPIRES: 06/05/2018 JOB DESCRIPTION: Reroof with OC Dimensional shingles; ice & water, drop edge, felt - 16 squares *** CONTACTS *** OWNER (303)462-5936 LOOMIS LINDA C SUB (303)328-3713 John Duvall 130171 Duvall Construction Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,500.00 FEES Total Valuation 0.00 Use Tax 94.50 Permit Fee 125.05 ** TOTAL ** 219.55 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A1/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€TMs installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Roofing PERMIT - 201701526 201701526 3285 Chase ST ISSUED: 06/05/2017 EXPIRES: 06/05/2018 Reroof with OC Dimensional shingles; ice & water, drop edge, felt - 16 squares I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed rs disclosed in this document and/or its' accompanying approved plans and specifications. Signat(re of OWNER or CONTRACTOR (Circle one) Date 1, Tfiis permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any r inance or re ulation of this jurisdiction. Approval of work is subject to tield inspection. �- ;J' Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of y, W heatRi e Commu 1iy DUVELOPMENI — Buildings & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: Plan/Permit 6V Plan Review Fee: *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: S P 5 04- r Je,, C. U � Oz L Property Owner (please print): ly Cc,, Loi, rv--� t S Phone: 303 - 410 Z..r 5g3 � Property Owner Email: A*—T� ` 3 4 t> 5 6&-)*+ Mailing Address: (if different than property address) Address: A M C City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: 0 LkV U 0 Dy1 lb 1 I(1 Contractors City License #: Phone: "7 2- d 7 1 Contractor E-mail Address: 1 n Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # /-30111 Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form C, O ' c Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION I&ESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) Q RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACNIENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. FULF �r%6 Btu's Amps dcv-4wc,4-6✓ ('�>"-:V,i-Fe ( t Gallons Squares / 4-0 y tither Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ .45t2&0. Ob OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE:(OWE =ONTRACTO r (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: �e r Y N— � V6J `I ` SIGNATURE: DEP ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required ENT USE ONLY DATE: S 0 — 1-1 OCCUPANCY CLASSIFICATION: Building Division Valuation: $ CITY OF WHEAT RIDGE V ' ,/ Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: i �j P 9 U v 'f n ❑ No one available for inspection: Time 1 ! AM/PM Re -Inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Dater Inspector:'` DO NOT REMOVE THIS NOTICE �Z�sa- S�- INSPECTION RECORD INSPECTION REQUEST LINE: (303) 234-5933 °ccupancy'Type� Electrical Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Mid -Roof Concrete Encased Ground (CEG) Foundation / P.E. Letter Lath / Wall Tie Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Comments Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric =C,J y3- , Rough Plumbing/Gas Line Rough Mechanical Rough Framing Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing i r Final Mechanical Roof Final Window/Doors Final Building yi j NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. `For low voltage permits - Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. "For Inspection Time Window Requests - Please email insptimerequest(ci wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather 3 Up 1— 1 1 1, I .) '-- 2- C S+.ICUl'�VU1`- -).-) INSPECTION RECOR Ii Ak 2W (t'Cf SL `� INSPECTION REQUEST LINE: (303) 2�4 5933 Uccupancy/T pe Inspector Initials Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter ✓V I.V� Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing L,FW I'IIJL VVr1i1 VIIYGI Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath /Wall Tie Rough Electric' Rough Plumbing/Gas Line Rough Mechanical Rough Framing Insulation Drywall Screw/ Nail Comments Final Inspections DateInspector Initials Final Electrical /C ;Z a Final Plumbing Final Mechanical Roof Final Window / Doors Final Building Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. _ r:...,.d +h�I In a vnitanc *For low voltage permits — Nlease tie sure ina> rough Inspecuuns c1lu LulllNq--« by the Building Division. "*For Inspection Time Window Requests — Please email insi)timerequest(d)ci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE ��9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F?" - MFT 'P Job Address: 3 C� - Permit Number: EJ — 1(:) 124 f - 7Q, ❑ No one available for inspection: Time P)PM Re -Inspection required: Yes No * When corrections have been mader vaXtor re -inspection at 303-234-5933 Date: l / Inspecte . ) DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE '` Z ��9r' Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: C" i: i Job Address: i '3 5; C : e T Permit Number: a U I (o h/ 'C ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: LM 2 , C fZ i Job Address: 3zb5- 041tSC 5'1 - Permit Number: 2c16 0 tJG1 { t � Gj ✓O til n (l �u+jL4O s('!fAli-f c.t.u�lr. V ' io.►2 t./l 14wee e IP-C'Ye, Un _ it (, nr,i-f',4, Ufh Ln/ /c410k A06/ e)'4- C I?(/P-CC Tote ❑ No one available for inspection: Time L/ -7 y Re -Inspection required: r5* No *When corrections have been made, call for re -inspection at 303-234-5933 Date: �G ` s"� �' Inspector: � DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �� S �� k I 1'I<1 I fV1 (2 i Job Address: Z S S C N f' SF ST Permit Number: 2 o/ 6 C / Sod r) els e _�U '1' (a L n, 5i� i t i IC a v✓ 14 C, P ( &-,w ✓�''���- ❑ No one available for inspection: Time AMC Re -Inspection required: Ye No *When corrections have been made, call for re -inspection at 303-234-5933 Date: -S �� Inspector: DO NOT REMOVE THIS NOTICE 1� A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 32- 65 (' N,4sc S-7 Permit Number: 2 0/ G o /,-/ 3 5 - MA <No one available for inspection: Time /2'A� Re -Inspection required:Yes ` No *When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE Date: City of �+ t^� lie 4�. �titt�4 UNi DEvr- O PMEN plan/permit Building & Inspection Services Division )"Q I w 15 a a 7500 W. i' Ave., Wheat Ridge, CO 80033 Plan Review Office. 303-235-2855 * ex. 303-237-8929 Inspection Line: 303-234-5933 Email: permits@6wheatridge.co.us Building Permit Application Please complete all highlighted areas on bath sides of this form. incomplete applications may not be processed. Property Address: LzzzS'e, Ll Property 0Ener (Please print): � " �► � Mailing Address: if different than properly address) ,Address: City, State, Zip: WEng n ' r E-mail: Phone.. Contl"actor Other City Licensed Sub: Other City Licensed uta: City License # City License # Complete all information on BOTH skies of this form s A d. d r 1V d r r y •� • r y r br dr • y.. r• d r �. r R y M y ; rNr y w r d. •� r r dlio III14 " ,« '° 8 • ,: ..„ '" -WarW,•,w df �+ IM k: Y IV 11 City of J?�Wh6atp_._idgle p I v 1�s IS, COMMUNrTy DEVELOPMENT City of wheat Ridge Municipal Building 7500 W.'291 Ave. Wheat lodge, CO 80033-8Cto1 F; 303.2352855 F 303.237.8929 The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough beat and ventilation are complete. The building should be fully enclosed with. the roof covering and siding in place. General Notes: Electrical - Direct burial conductors shall be a minimum of 24-inches deep, non-metallic conduit 18-inches, deep or 24-inches under driveways. (IRC Table X31103.1) Water Lines - shall be a minimum of 36-inches deep. (IRC P2603.6) Comas Service Piping - installed a minimum of 12-inches below grade or -inches below grade where serving individual outside appliances. An 18 A"WG yellow insulated tracer wire mast be installed adjacent to underground nonmetallic gas piping and terminate above grade at each end. (IRC G2415.1.2 and G2415.17.3) 4 Underground plumbing pipe shall have a solid and continuous load-bearing support, Piping cannot bear on rocks. Pipes passing under a footing or through foundation wall shall be provided with a relieving arch or a sleeve. Trenches parallel to footing shall not extend below the 45° plane of the edge of the footing. Water piping must be buried a minimum 36-inches deep. "Water service pipe may be installed in the same trench as the building sewer provided the saver pipe material is listed for underground use within the building or the water service pipe is separated from the sewer by a minimum distance of 5-feet horizontally or elevated at least 12- inches above and to one side of the server line. 5 Frost depth to the bottom of the, foundation footings must be as noted on the engineered plans. If not noted, the frost depth to the bottom ofthe footings must be a minimum of 30-inches below finished grade. (IRC TablR3012. l 6 Caisson and helical pier foundations will not be inspected by The city of Wheat Ridge. A qualified, Colorado- licensed engineer must perform the placement, drilling, and reinforcement of drilled piers. A signed, sealed and. dated inspection report must be provided: to wilding Inspection Services prior to the rough inspections Rl 10.5.2.3) o A perimeter drain system that discharges to an approved drainage system is required round all foundations that enclose usable spaces below grade. Foundations that retain earth and enclose interior spaces below grade must be damp proofed. (IRC R405. 1, R406. 1, ) Slabs below grade must maintain a minimum of 6-inches above the design water table. The interior finished crawl space grade must be a minimum of 36-inches above the design water table. ( R401.2.1.3and 8401.2.1.5) 9 Garage floor surfaces must be approved noncombustible materials. Floors must be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. (IRC R309.1) 10 Foundation plates and sills must be bolted to the foundation wall as prescribed on the engineered plans. If not noted, bolts shall have a minimum diameter of %- inch, embedded at least 7-inches and spaced not more than 6-feet apart. A minimum of 2 bolts are required per plate section, with one bolt located within 12-inches of each end of each plate. (IRC 8403.1.6) Ighe hFra ing and Wood RequirementsW 1 complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and >heat and ventilation are complete. The building should be fully enclosed with the roof covering and siding in place., www.ci.wheatridgc.co.us ?*I¥ y<£«»« «2�2» «.a ? « 2a<» «:�«:« «: <: ? »»:w» ©© w » «;2�.» w »:&2 «°«� . ....: .a...:»»..+:...� f<+w<?£�«+« iw w 2< t��v::?» w « »< ©:»��<?�«.2. «» w.�w<w » y \ w<<� «»�:» 2 - r< ».,v, ».,�, <2 » » � » »,: w� « ©� » « » .}� � : »a,..w; »<< >.:.» . «.�«.< »� » ■�<w§<«!«.:,�2««©«,» ©< :,<:».c�:�««««<�;.«,©.»a. 2.«.«;«,»»»:;:«.,«m:�«/.«»»m;«.«<:a::,°:«,<w »-2:»w «»:;©�»<:«»?:� ?,» »2« «»�.:«,£�<«� «»<« w»«..w�<,«»« «: m:w<«...� »2,<.< ««, 2»» <?« �«:<««« «<*� «�<. ««.»2»�2.2�»�««©r<<«�y;«:«..�. » »? m »»»:�»?,�« a > w «,e ; y £�° ^.! a,� : 4::,<¥:: «,� »::*»z:« s:« 2;1y �,�� ,r�< w:«: .<� «E«« .: »42:£ : � y «� m t � w< » »�» ?., 2 w�;.��,� »:< . » .?». < � «, «:.,, �:�, » � :» » », ». 2 »� « w:E»� 2,«�� wr* «:< r,�<+» w <�r:� ;<.w ::� » < & 4 ;,* 2 ��.a� f6» «»» a t«, »< ?« ? �» « <?v�? «°:«�� ?: »�.w <� », »»:<, » ?,<. < <« ..»< « »� »2 » �:» » ».< ...... »... .>.�. ��� .\ : l�:... : . . . �...»:.<:»....w:..,... :« w<».» ?»�» ,2wm,��»y2�� :222«2 ?� :.- «-? ?2�:,;:»-«» a��©»�t. »«: . �.� + © ��� «�rwy ©»*z44?< w&»� ^ �©� © »»*2» «v«, « 4»� ©?:!»?»»<»:¥««4<»:<ey«<�a»::�:§w:d«��»<»�.«»,.?<2?«? <«ywr,»»«, :?2 ? 2 y wJ «�<w<: <»£,� » a»� 2:.©«<2.�»».�» ;»�y:<�..a ��■ » ? »« .��.- ©<«c«: « a:d;?»�. ««,2� . »« w 2,<<< w 2 »: » 2 » » y,a�:�!!< © w »< » « ?�« »,. ? <«.:« «�:<�. « ? 2»» ,� .^� ;:.«42» �w? «.»:�<»w».» »,»y.:,�:<v»22© ?«� 2 <»».,#©«;?>«: F. Skylight U -factor required U-0.45. Skylights installed on roofs flatter than 3 units vertical to 12 units horizontal must be mounted on a curb 4 -inches above the roof OEM M UUdQICU LO Inc st U ;u,..v��ii=tcrawispacess4alivupiv insulation, Ventilation (IRC X303.1 bedroom or bathroom in and such enclosure is provided with a solid weather-stripped door, a self-closing" device and all combustion air is taken from the outdoors. (IRC G2406.2) 49 Gas logs installed in solid fuel homing fireplaces shall be tested in accordance with ANSI Z21.60 and installed per the manufacturers installation instructions. Gas logs installed in bedrooms must be direct vent or provided with an approved source of outside combustion air. The approved gas lob set must be installed in the Solid -fuel burning; appliances at the final inspection= (IRC" G2406, G2432, and G2434) tt Solid -fuel -burning fireplace stoves, fireplace inserts or wood stove appliances shall conform with emissions testing, certification and labeling requirements per Title 30, Article 28, Sections 402-405 of the Colorado Revised Statutes: The Air Pollution Control Division of the Colorado Department of Health must certify these appliances to meet the emissions standards of Section I' of Regulation No. 4 of Volume I of the Colorado Air Quality Control Commission as EPA Phase 11 or Colorado Phase 111 solid-fael-burning solid-fuel-burningdevices. l B,1 BW, and L vents and factory -built chimneys must be provided with a clearance to combustibles per then a manufacturer's listing. Where vents pass through insulated assemblies, they must be provided with an insulation shield. A clearance ofq-inches is required between single wall vent connectors and combustibles. Gas vents must penetrate through the roof flashing, jack or thimble and tenninate in a Chimneys listed cap or per the manufacturers listing. Decorative shrouds installed at terminations shall be listed and installed per the manufacturer. (IAC G2425, G2426, G242) 52 Chimneys shall be protected with a spark arrester consisting of 19 `gage galvanized steel or 24 gage stainless steel, with openings not exceeding !/2 -inch. (IRC R1003:q.2) Electrical Requirements 11 electrodes present at each structure shall be bonded together to form one grounding electrode system to include: Concrete' Encased Electrodes (l. FER), water piping, ground rings, grounding rods, and plate electrodes. Bonding shall ensure electrical continuity. The electrode conductor must be connected in an approved manner and inspected prior to concealing. (IRC E3607, E3608, E3609, E361 ti, E3611) 411 hot, neutral, and grounding; conductors in electrical boxes shall be tied together with a mechanical vection at the time of rough inspection. 55 ce sed lighting fixtures'must either be IC -rated or installed in a sealed box in which the insulation is at 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through the fixture into the ceiling; cavity. (IRC NI 102.4.5) u 1 =en, istant f eceptacle outlets are required in every :kitchen, family roam, dining room, living room, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet, (IRC E3901, E3902, and 4002.1-4002.14) A. Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the counter top and spaced so no point exceeds 4 -inches from an outlet. B. island and peninsula counters with a length at least 24 -incites and a width of 12 -inches or greater must be equipped with at least one outlet. C. At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. D. A least one receptacle' outlet must be installed in each laundry, basement, attached garage and detached garage with power. E. At least one receptacle outlet that is accessible while standing at grade level and located not more than6-feet. 6 -inches (1981_ min) above grade, shall be installed outdoors at the front and back of each dwelling; unit haying direct access to grade. Balconies, decks, and porches that are accessible from inside of the dwelling emit and that have a usable area of 20 square feet. F. Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet Within 2 -feet of the equipment. ti. Hallways' 1 0 -feet or more in length: 2«*»»«w»1«»}»,«?«« y«<<.22 »»<»«»«2» «2»\«« m<�.<«.?»?»«««: »2?»» « » » « a w, »c« » 2,2}v:l v: »al w: »:»«m<«2:1a «,»»:� ..f«. ww.. :4«: «4««t�<s� ��» »4« t».»»»w» w?:.a«»w« 2.w«<.<d«»�,<»..:«�«?<<.<�< «,.«2��<?<,? »>« * «:w 2; » w<< ? a . � a 4 » »�� < : .».,.\ .�. .v. ..\ . a.:. a a »�:.« .:.:v.:.\,..�. <� �< 4«.. °�««£» 24»<:*«*2: <<* «*<;« »..: «4�«ze :.:. , . 2 t<. ,�« t<y<2»»w»»?:©�«:«<©»�<«2»2,:< »:y»:»��«.»:�«.» »«» :«:w»«»» +»«,�a,.«»»<:»:�.r?».m»»«w«:!<j«<«:»©y<?,.? m2:�§»�w<»»<»««.:««?2. »:2» ««y»» » a «<4 «r r w «� :ate «E« :«e«:;c » ::� .»� « y¥?:!<¥�»: 4� 2« »� !<�<;m ». J<»„< »24»..:»« a:« v »::«»2 «., »:« » �:� »<x . .©»»; . Plumbing 66systems shall be tested on compellation of the rough piping installation by water or for piping ssystemDJ�Vv than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed . 1) Water test 10 &et above the highest fitting connection or to the highest point of the completed systern. The system shall prove leak free for 15 minutes. 2) Air test shall maintain .5lbs of pressure for 15 minutes. 67 Piping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC. P2503, P2603, P2608. I) 68 Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb threshold not less than I -inch below the sides and back of the receptor. The curb shall measure a minimum of 2 - inches to a maximum of 9 -inches above the top of the drain. (IRC R307, P2708, P2709) 69 The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, and lavatories must have a minimum clear space of 2 1 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 70 Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic mixing or combination pressure balance/thennostatic mixing valve types with high limit stop per SSE 1016 or CSAB1 25. 1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 120'. (IRC P2708.3,P2713.3) 71 Shower doors shall have safety glazing, hinged shower door shall open outward (R308.4.5, P270& 1) 72 Swimming pools, fountains, hot tubs, spas, and hydro -massage "Jacuzzi" tubs and similar installations shall comply with all provisions of the IRC for the approval of bonding equipment and lighting. All 15 and 20 amp, single-phase 125 -volt receptacles located within 20 -feet of the inside walls of pools, outdoor spas and hot tubs shall be protected by a GFCl. Motors and equipment must be accessible without damaging the building structure or building finish. (IRC E4202,E4203, EE4204IE4205, E4206) 73 The reinforcing shell of the pool shell, metal forming shells, coping stones, deck, brackets of niche fixtures, metal fittings, and electrical equipment, located less than 5 -feet horizontally and less than 12 -feet above maximurn water level of swimming pools and built in place hot tubs shall be bonded together. The parts specified above shall be connected to an equipotential bonding tyid. (IRC E4204.2) 74 Where drainage is roughed -in for future fixtures, the installation shall be terminated with an accessible permanent plug or cap fitting. (IRC P3005.1.6) 75 Backflow prevention must be provided to prevent contamination of potable water. This includes but is not limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers. (IRCP2902.2, Table P2902.3, P2717) Insulation ,_',i-49 ceiling R-19 crawlspace Windows.32; Floor 1t-30 77 Foam plastic must have a flame spread rating of not more than 75 and a smoke development index of not ore than 450. Foam insulation must be separated from the interior of the building by a !/2 -inch gypsum board or an approved thermal barrier. In an attic or crawlspace, foam may be protected by: I %2 -inch mineral fiber insulation, -inch wood structural panel; 3 -inch particle board; 'e4 -inch hardboard, -inch gypsum board, or corrosion -resistant sheet metal not lest that .0116 thick. (IRC 8316) 8 Combustible insulation shall be separated a minimum of 3 -inches from fare motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. (032426.4 and BC Amendments N 11 12.4.5) 79 Class l or 11 vapor retarders are required on the interior side of the insulation in framed walls, floors and roof/ceilings of the buildings thermal envelope. The vapor barrier is not required in construction where moisture or freezing will not damage the materials, or where the framed cavity (or space) is ventilated to allow moisture to escape. A vapor retarder is not recommended on a concrete basement foundation wall or in a shower `batt compartment (IRC 7017, R702.7.1). Comply with the manufacturers specification cation listing for the product installation, 80 The garage shall be separated from the residence and its attic by materials of not less than 1/2 -inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5 8 -inch Type X gypsum board. Where the separation is afloor-ceiling assembly, the structure supporting the separation shall also be protected by not less than '/-z-inch gypsum board. (IRC R30.6) Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in thickness, solid or honeycomb core steel doors not less than I -inch thick, or 20 -minute fire -rated doors. Openings are prohibited between garages and rooms used for sleeping. (8302.5.1 )Doors between attached garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be self-closing and self -latching. 81 Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with z 2 -inch gypsum hoard (IRC R302.7). 82 Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic the or other required nonabsorbent finish material shall conform to ASTM C1396, CI 178 or 01278. It is permitted on ceilings where framing spacing does not exceed 12 -inches oc. for !/2 -inch thick or 16 -inches o.. for 5 8 -inch thick: gypsum board. Water-resistant gypsum board shall not be installed over a vapor retarder in a shower or tub compartment and may not be used where there will be direct exposure to water, or in areas of continuous high humidity. All cut and exposed edges shall be sealed. (IRC R70.3.8) 83 Cement, fiber -cement, glass mat gypsum backer and fiber reinforced gypsum in compliance with ASTM C 1288, C 1325, 01178, or C"1178 and installed in accordance with manufacturer recommendations shall be used as backers for wall the in tub and shower areas and wall panels in shower areas. (IRC 8702.4.2) 4 Gypsum Board Applied to Ceilings: (IRC Table 8702.3.5) A. 3 8 -inch. Thick Material: Framing 16 -inches o.c. with gypsum applied perpendicular to the training. Fasteners shall be 13ga nails or 4d cooler nails spaced a maximum of 7 -inches or type S or W screws spaced a maximum of 12 -incl es.lf, 1/2 -inch Thief Material: Framing 16 -inches o.c, with the gypsum applied either direction or framing 4 -inches o.c. the gypsum must be applied perpendicular to the framing. Fasteners shall be 13 a nails, 5d cooler nails or gypsum board nails spaced a maximum of 7 -inches or type S or W screws spaced a maximum of 12 - inches. -inches. Textured ceilings shall be sag -resistant gypsum applied perpendicular to training at 16 -inches o.c. and24- inches o.c. Gypsum board thickness shall be a minimum cif'/2-inch for 16 -inches o.c. and. 5/8 -inch for24-inches o.c. Fasteners shall be 13 a mails, 5d or tid cooler nails or gypsum board nails spaced a maximum of 7 -inches or type S or screws spaced >a maximum of 12- ache . `. -inch `thick Material: Framing lei -inches o c. with the gypsum applied in either direction or framing 24 -inches o.c. gypsum must be applied perpendicular to the framing. Fasteners shall be 13 a nails, dad cooler nails or gypsum board nails shall be spaced a maxim of 7 - inches or type S or W screws spaced a maximum of 12 -niches. Type X ;gypsum board for garage ceilings beneath habitable rooms shall be perpendicular to the ceiling framing by l -inch 6d coated nails or equivalent drywall screws spaced at -inches o.c. Cance these items are received, the plan review can coanmence. Please let me know if you have any questions or need additional information, 'max, Insulation and Fenestration Requirements Fenestration U factor 0432 Wood frame wall R Value 20 or 13 +5 Gelling R- Factor 49 Floor R —value -30 Basement Nall R-hal e 15/19 yq 7 A-) ,` "c Oca L 57 'City m ct ` eat Ridge BLMdir-i Division DJ3L_ Approved F'O"Ins Cr tr'CRY ire V011dtY Of Permit: Thea issuance of a wrnit or cpWovd of pkr* cOMPutotions shON not t of the ' codo or of ..n y City ordnonces, Pemuts t -tO v to of of the City OioD not be vobd. XAV LOcity Wheat so IW co Iry m ft VVI .Z rNsol,04a,On RP8,0110E6 vim' 5c 1, C- fe 0 0 9 0 L) ofo�, city of Wheat Ridge FOR OFFICE USE ONLY �- Cit}/ C� Crate. �Wh6atj jdgieW jq A, COMMMOUNtTyDEVELOPMENT ENT Pian1p!t 1 1Y Building & Inspection Services Division 7500 W. 2e Ave., Wheat Ridge, CO 8 033 Plan Review Office: 3013-235-2855 * Fax: 303-237-8929 Inspection Line 303-234-5933 Email:errnits ci.wheatrict e.c .0 Building er it Application Please complete althighlighted,arvas on both sides of this,form. !n plet+ pl1 a ina not l pr s Property Address: �x Property Owner (plea ,print). � �� � Phone.- Property hon+ :Property Owner Email. Mailing Address: (if different than property address) Address. City, Mater i ArchitectlEnginser E-mail: Phone: Contractor: -10'Q5 Contractors City License #: Phone: 30 5L Contractor E-mail Address* Lo SubContractors; Electrical. Plumbing: Mechanical: WR City License # W.R. City License ## W.R. City License ## Other City Licensed Sub: tither City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form Nw �.. w 1 ¢ ..fir • ar. ..�.. . �. *. �" � - y e w • r .!. ...E ,�. .ia Tm4i i13i�e4SG+v rG#PYT,. VW W- U�'b'ir'idy 'W.+At✓.� r^, p Sq. FULF Stu`s Gallons Amps 1 Squares Other Date. .. Your � ois sit for �Lk,. k. � MV,• _l�. i Quentin St. Suite #114 Aurora, CO 80011 I Procedures for closing a pertnit where a final inspection is needeM Permits are often required by your city/municipality when installing piers and/or wall anchors. We will work with the Engineer and Building Inspectors to ensure your home receives the best possible resolution for your particular problem. The following is a brief description of requirements needed to close your permit in a timely manner. Please expect the pennit to be posted at your home until the permit is closed. Your city/municipality DOES require a final inspection. The day of the inspection, you will need the following: 1. Pe it, which should still be posted at your home. 2. Engineer's report 3. Engineer's final inspection letter. ** If you do not have any of these items, please let me know and I will get them to you directly. Once the inspection has passed, the city/municipality will close the permit. Please note that the work we have done cannot be concealed in any way, before the final inspection. As an example, please do not drywall or cover wall anywhere piers/ wall anchors have been installed. If you have any questions, please do not hesitate to contact us, Sincerely, Andres Gooding Production Managgr Complete Basement Systems 303-805-8751 DL Engineering Inc, Structural / Civil Engineering 2750 South Wadsworth Blvd D-203 Denver, CO 80227 720-W-9450 diemier@dlengineer.com www,diengineer.com 5/23/2016 �A_401_.Awl 3250 Quentin Street, #114 Aurora, CO 80011 RE: Job Number 2016-1241 Site Observation Visit (Loomis) 3285 Chase St. Wheatridge, CO 80212 DL Engineering Inc. reviewed the progress of construction for the subject project on May 101, 2016. The following is a summary of the observations made: rigm,W] • Reviewed the helical piers. The helical piers appear to be installed in conformance with the structural mitigation plan. • Site grading around the perimeter of the house did not appear to be modified. • Vegetation around the perimeter of the house did not appear to be modified. Volatile Soils: The moisture around the foundation elements must be controlled for the useful life of the building, Time has shown that Colorado soils can be unstable and structures can experience damaging movements due to expanding and shrinking soils, primarily when moisture changes occur. Maintaining consistent soil moisture contents around all foundation elements is crucial to minimizing foundation md, �� S*AM747-09 exert excessive pressures causing damage in the residence. If the Owner would like further insight about the on-site soil conditions and preventative measures, a Geotechnical Engineer should be consulted. It is possible that the piers may consolidate the soil under the piers. Because of this, periodic surveys of the supported structures should be conducted to assure project success. The Owner should be responsible for annual surveys certifying project success. It is recommended that a baseline survey be conducted immediately. The Owner should report all findings and reports to the Structural Engineer. If vertical movement of the foundation walls is discovered, the piers should be re -pressurized. A Geotechnical Engineer should be present for the re -pressurizing of the piers. Disclaimer: In as much as the site review of an existing structure for the purpose of observing the structure conditions requires that certain assumptions be made regarding existing conditions and because some of these assumptions may not be verifiable without expending additional sums of money or destroyin i *therwise adequate or serviceable portions of the building, the Client agrees that, except for negligenQ DL Engineering Inc. Structural / Civil Engineering ( W r ler itTesmns, pfease tee e to contact me a 0 • Sincerely, Ifatt We4ter- EIT Garrett Townsend, PE "'I FUR}FFIC E USE O � . Date.' Cityof .; Whea *d e BuildingPermit & Inspection Ri W. 29tAve.,Ridge, CO 80033ReviewPlan Office.303-237-8929 Inspection• 111 N 1 IN 11 lip! xo, Address: 5a 9 E5 ChOSS d t+ e mRIM. Lwlilil I J= Sub Contractors: Electrical: Plumbing: !Mechanical. WR. City License # W, R. City License# Wli City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # �Ullljfjfiaf: + i NEW ELECT VICE RESIDENTIAL COMMERCIAL �Il y� d Y. M.. M� 4. w 1N1 • i.. NEW FING Y,iY yt COMMERCIAL > i MM O �y T COMMERCIAL N RESIDENTIAL ROOFING RESDENTIAL ADDITION D WINDOW REPLACEMENT COMMERCIAL t ♦Y STRUCTURE IMY w.,;. +:r s RESIDENTIAL, sh MECHANICAL SYSTEM/APPLIANCE A YY.A M Y A'MI`. REPLACEMENT Y. i PLUMBING SYSTEM/APPLIANCE Y* i o. REPLACMENT ELECTRICAL i A wM. Y. A Y•a.Y� Y w i ATe : r i` s i Fbund6fi 00 5q. FULF Stu's Gallons Amps Squares tither DL Engineering Inc. Structural / Civil Engineering 'PPA Sq;OU #q6O*9*WWMWW**4*Rl2 BUIP11nil OW POWISIAM MOOMMAW01 AW0410111 *A16 01 BU!WftUW "UWJ 1"Molo Am 1plinq stir to suolisihoid 0*)o AW '01 WPAA XU1'JO ad jou 11#4s suopindwo* put 4/21/2016 gnss! i :VWJ8d 40 AM. 9A Complete Basement Systems -4 1 ins 3250 Quentin St., #114 Aurora, CO 80011 RE: Job# 2016-1241 pe dV Waill ea 1plIng a6p1N lea4M Loomis 3285 Chase St. HO'J , Wheatridge, CO 80212 As requested, a site visit and observation was performed at the pro e at the address above on Tuesday April 12, 2016 at approximately 2:00 p.m. The purpose for the site visit and observation was to review the structure for movement of the foundation. The subject property is a single family home with a crawlspace located in an established neighborhood. The house was built in 1940 (based on an online search of the Jefferson County Assessors records). The foundation is constructed of concrete and is assumed to be on spread footing�s. The ho poed ous apears to be cnstructf conventional ood o wframing. The observatin was visual and structure. For purposes of this report we assume that the house faces east. Vertical cracking in exterior of foundation wall Previously repaired vertical cracks in exterior of foundati Cracking in drywall at ceiling Previously repaired vertical cracks in interior drywall Vertical crack in crawlspace foundation wall I mg* * The cracks observed were likely caused by vertical movement of the foundation walls. The the foundation. The following is a list of recommended repairs: In Ll p� Foundation illsPections shall be pr'ti.)nned by the engineer of'record and verified to the, Building Divisiol, by wet -stamped latter- of approval, DL Engineering Inc. Structural / Civil Engineering ME= The moisture around foundation elements must be controlled for the useful life of the building. Lack of proper drainage is often a contributing factor to foundation damage observed, The site drainage around the structure must be maintained such that -tm- P -0-4-p* 0'er-qw- barriers, swales, and surface/subsurface drainage systems are strongly recommended. that they discharge a minimum of 10 feet away from the structure. Mnl�� movements. Vegetation can hold moisture in soil and create excessive pressure on th foundation system. in order to reduce the risk, bushes, shrubs, and trees should be carefully removed by an experienced professional. Care should be taken to not furthe disturb or damage the existing foundation system. Planters and other surface features which could retain water should be eliminatedand j 0r**,erly gr2*&� t+ reiluce t"*ssikility n. f m*isture i%fittr,?ti%g;, fiou,41W*1 In as much as the site review of an existing structure for the purpose of observing the structure conditions requires that certain assumptions be made regarding existing conditions and because some of these assumptions may not be verifiable without expending additional sums of money or destroying otherwise adequate or serviceable portions of the building, the Client agrees that, except for negligence on thert of th Pa : ;gain againis any and all claims arising out of the professional services we have provided. I APPROVED Subject to Field Inspections Wheat Ridge Buflding Dept. ate. Signe, P �1 n DL Engineering Inc. Structural / Civil Engineering Figure 2: Previously repaired crack with new ROVED �ied lrispezfions m;Akgiping Dept. Date I lan Chec!Ie,� DL Engineering Inc. Structural / Civil Engineering Figure 3: Previously repaired crack in dr of R 0%,," "L" D Reid �nspeclions DL Engineering Inc. Structural / Civil Engineering In as much as the site review of an existing structure for the purpose of observing the structure c**Vitioxs re,4uires tk2t ceatA* ,Assum�bi" ke m�z!Oe re&,,Ar��Ug existi*g c**fiti+*s qz*d kepluse some of these assumptions may not be verifiable without expending additional sums of money *r iestr*yh% *Aerwise ?1,e*u,2te-*r seNiceqkle �u*rti*,x;s +f tke �milVixg, tke Clie. "t., rees-tk2t, except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and defend Engineer from and against any and all claims arising out of the professional services we have provided. . ►. - - - W, gtownsend@dlengineer.com. Sincerely, &1W0V6i9dX,1U&-4d�flU116 APPROVED Subject to Field lnspection','., Wheat RidqL, euil&pl 11 - i E 9 ept. Date,, 1P REM C h OL ENGINEERING INC. I -�� 2750 S. WADSWORTH BLVD. FOUNDATION STABILIZATION AT RN= UNIT D-203 3285 CHASE ST. DENVERi, CO 80227 WHEATRIDGE, CO 80212 720440-9450 OWNER.- LOOMIS WWW.DLENGINEEILCOM INDEX: BUILDER INFORMATION: SI -1 GENERAL NOTES SI -2 GENERAL NOTES Complete Basement Systems of CO SI -3 GENERAL NOTES/ LEGEND 3250 Quentin Street Ste. 114 S2-1 FOUNDATION PLAN Aurora, CO 80011 S3-1 TYP.HELICAL PIER DETAIL 1-303-805-8751 General Notes: I Construction documents are valid for a single use at the project location and shall not be reused, copied, or reproduced without written approval of the registered design professional in reasonable charge. Z The contractor is responsible for the methods, means and sequence of all structural erection except when specifically noted otherwise in the construction documents. The contractor shall provide temporary shoring and bracing, providing adequate vertical and lateral su., - rt durin- erection. Shorin and bracin-, shall remain in Place until all Rarmanent members areglaced and all final connections are completed. 1 The contractor agrees that, in accordance with generally accepted construction practices, the contractor will be required to *N, site oct", itcts 14 40 Field Verification: I , Contractor and Owner shall thoroughly inspect and survey existing structure to verify dimensions, elevations, framing, etc. which affect the work shown on the drawings. Z Report any variation or discrepancies to the structural engineer before work proceeding. Foundation Design: I Soil conditions and types shall be verified by a Geotechnical Engineer during excavation, 2, Follow all recommendations of the Geotechnical Engineer for foundation elements. 3. All helical piles, push piers, helical anchor tiebacks, wall anchor tiebacks and connection hardware shall be designed an n1acities shoic on the drawings are unlactored service loads and have not been reduced for live load reductions. 4. All steel for helical piles, push piers, helical anchors tiebacks, wall anchor tiebacks and connection hardware shall be hot dip galvanized. 5Design of individual and continuous footings is based on a maximum allowable bearing pressure of 2000 tbs. per square foot (dead load plus full live load), placed on the natural undisturbed soil, or compacted structural fill below frost depth. Design Criteria: I , Building code: 2012 IBC, 2012 2. Deadloads 2ARoof 12psf 22 Floor 10psf 23, Walls I Opsf 3. Uveloads, 3A Residential 40psf 3-Z Roof 20psf 4Snowtoads 4.1 Roof snow load 30psf A 5, Wind loads 5.1 Exposure Category C 5,2 Basic Wind Speed = 105 mph IRC w/ City of Wheatridge Amendments SUbjeCt to Res�cj 1�,-SPC,,c,tions Wheat R'dge 60dkng Dept, Date,, g ad ne _ k_ -Plarl Checks" ..... . ...... I OL ENGINEERIORTHNG INC. 27SO S. WADSWBLVD.=Mal UNIT D-203 FOUNDATION STABILIZATION AT 3285 CHASE ST. DENVER, CO 80227 720-440-94SO WHEATRIDOE, CO 80212 OWNEW LOOMIS WWW.DLENGINEER.COM 1, All concrete design is based on the "Building Code requirements for Reinforced Concrete" (ACI 318-05/318R-05) All structural concrete shall have a minimum 28 -day compressive strength as follows: 1.1 Footing,000psi 12 at on Grade- 3,500psi 1.3 Foundation walls: 3,000psi 2, Concrete shall be placed on proportioned utilizing Type I cement except, concrete exposed directly to soil shall use Type 2 cement. Concrete susceptible to freeze shall be formulated or maximum frost resistance in accordance with the ACI manual of Concrete Practice, 1 Cold weather and or hot weather placing procedures shall be provided, if conditions warrant, as recommended in the ACI manual of Concrete practice. Reinforcing Steel: I All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the ACI Manual of Concrete Practice, Z Reinforcing bars shall conform to ASTM A615-79 and shall be grade 60, 1 Except as noted on the drawings, minimum concrete protection for reinforcing shall be in accordance with ACI 318-05/318R-05. 4No. 5 or larger reinforcing bars shall not be re-bent. 5, Welding of rehar is not permitted unless procedure is approved by the Structural Engineer, Structural Steel: 1. Structural Steel shall be detailed, fabricated and erected in accordance with 2010 AIS C Specification for Structural Steel Buildings, and "Code of Standard Practices" 2005. Z Structural Steel shall be confirmed to the following grades: 21 W- & WT- Shapes: ASTM A36, A992 2.2 Plates & Angles: A36 23 HSS- ASTM A500 gr B 2.4 Steel Pipe: ASTM A53 gr 8 3, All bolts shall conform to the ASTM A325 except anchor bolts which shall conform to ASTM A307. Bolt Size shall be Y4", unless noted otherwise on the drawings. 4. All welding shall be bye certified welder in accordance with ACIS and AWS specifications and recommendation. taa - - - - - - - - - - - tiuii,tXn-and-size-offtails,indicated in APPROVED . . .... ........ re treat& aft a t t equal, ited or detailecL rZTRX*1G'VAUTejS: 1 Periodic surveys of the supported structures should be conducted to responsible for annual surveys cerfifv_ing-pm:ie-�-uccesr�,-.-We-woul-d-&Qgec baseline survey be conducted immediately. The owner shall submit all Wndin�" reports to the Structural Engineer, 2, If vertical movement of the piers is discovered, the piers should be re-pressurecL A-reprnse tive of th, observe the re -pressuring. A final report should be provided by the Geotechnical Engineer after observing the re -pressuring. Foundation Stabilization: I , Although observed foundation damage typically does not pose an immediate f health and hazard risk, delaying mitigation will likely make future repairs more difficult and costly. Furthermore, it has been our experience that once a structure begins moving, it will likely continue to so (unless action is taken) resulting in further settling, 9t tr» OIL ENGINEERING INC. 2750 S. WADSWOVl RTH �. » r BLVD- FOUNDATION STABILIZATION AT UNIT D-203 3285 CHASE ST. DENVER, CO 80227 WHEATRIDGEo CO 80212 1120-00-9450 OWNIER: LOOMIS L VArDI)LENGINEEMCOM neaving, unsightly cracks, 7loorsviclows not Tunctir property am possiole tountlation wait MUN• The Omni ana aggressiveness of the foundation repairs should be carefully considered by the Owner and will depend on their tolerance for risk, the possibility of future damage, and cost. 2If the owner chooses to do so the foundation could be stabilized only at visibly damaged locations and areas where movement is concentrated. Although this will address specific situations, it is possible that foundation movements will occur elsewhere, 3. If the Owner chooses to do so, the entire foundation could be mitigated. A general system repair, although more costly, would greatly reduce the risk of future foundation damage and movement. It is out understanding that the Owner would not like to pursue this repair option. Site Drainage I .b that the moisture around foundation elements must be controlled for the useful life of the building, Lack of proper drainage is often a ormtributing factor to foundation damage observed. It is our opinion that site drainage around the structure must be maintained such that precipitations will quickly drain away, The use of proper slope slabs -on -grade, moisture barriers, swales and surface/subsurface drainage systems are strongly recommended. Extension should be attached to property function downspouts and roof drains discharge a minimum of 10 feet away from the structure. Site vegetation I . We believe that vegetation around the perimeter of structures can eventually lead to foundation movements. Vegetation can hold moisture in soil and create excessive pressure on the foundation system. In order to reduce the risk, bushes, shrubs and trees should be carefully removed by an experienced professional. Care should be taken to not further disturb or damage the existing foundation system. 2, Planters and other surface features which could retain water should be eliminated and properly graded to reduce the possibility of moisture infiltrating around the foundation, Irrigation systems and excessive moisture adjacent to structures can introduce unwanted moisture, possibly resulting in settling and or heaving. The Owner should consider removing irrigation systems or simply not use them. kisclaimer� I In as much as the site review of an existing structure for the purpose of observing the structure conditions requires that expending additional sums of money or destroying otherwise adequate or serviceable portions of the building, the Client agrees that , except for negligence on the part of the Engineer, the Client will hold harmless, indemnify and defend Engineer from and against any and all claims arising out of the professional services we have provided. I Cr- is I P pir? f, (E) EXISTING (N) NEW PUSH PIER P.P.#X PIER # (xxxx#) LOAD ON PIER WALL ANCHOR W,A. #x ANCHOR # NO POST ,P, #x PCT# (xxxx#) LOAD ON PIER HELICAL PIER FI. P. #X PIER # (Xxxx#) "-- LOAD ON PIER V t- 8U*'Ct E DL ENGINEERING INC. 2750 S. WADSWORTH BLVD FOUNDATION STABILIZATION AT 7, UNIT D-203 3285 CHASE ST. RE)ASION DATE DENVER, CO 80227 WHEATRIDGEl CO 80212 17 720440-94SO OWNERC"EOKED LOY: : LOOMIS W DLENGINEER.Com [L D WW - 26' - ------- 110. NOTES: 1. SEE SHEETS SI -1 THROUGH S1-3 FOR GENERAL NOTES, 2, INSTALL HELICAL PIERS PER PLANS. v w NK:::Imm V E D Inspections BuM�rig Dept, Date" I `VLlliu��lllENGINEERING �priolii�u �lINC. 2750 S. WADSWORTH BLVD. FOUNDATION STABILIZATION AT sum= UNIT 0-203 328S CHASE ST. DENVER,+ WHEATRIDGE, CO $0212 720 ...; e • • MIS WWW.DLEt4GlNEElt.COM BOLT HP BRACKET TO FOUNDATION Ind (2) x 7" ALLTHREADEPDXY INTO FOUNDAITON .. a S' MIN ••" 11 BEARINGSLEEVE AND A � Mit 3 Mr 1F M IM It I 8 8 City of ,](�, " �Com •e * sr ( ple ase t rint): Phone: " • • rs City License #: Phone Electrical: Plumbing: Mechanical: City License # City License ## City License ## (Fully describe work to be performed - Attach additional sheet if necessary) w �Y O Review Fee (due at time of submittal): Squares BTU's Gallons limps r � sJ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 15745 Date: 6/24/2003 Property Owner: LINDA C. LOOMIS Property Address: 3285 CHASE ST Contractor License No. : Company: Phone: 462-5936 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Total: $1,700.00 $78.19 $0.00 $34.00 $112.19 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat *Ridge ordi~ces, r ark under this pe/"_ ,/ / (OWNER)(CONTRACTOR) SIGNED (; , ATE~..3 Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description: ADD SIDING TO 3 GABLES (E. W. & S. SIDE OF HOUSE). REPLACE 2 WOODEN PORCH POSTS WITH WOODEN DECORATIVE POSTS. BUILDING DEPARTMENT USE ONLY Zoning Commeii.t~~ Approval: Zoning: :S'uilding~oinnieot!;: Approval: "<M"~"",'<i Public Works,eqmments: Approval : Occupancy: Walls: SIC: Sq. Ft.: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical license No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (Al the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the P'OVISI~;;J'j b~es 0' any othe, oedlnanee, law, wle 0' ,egulatlon. ChieMt~.tg'1 s~ ~' "H'" ~ .::- ~ '0 - '" U ~ COI.QRf>,tP COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH A VENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPLICATION Building Permit Number: Date: Property Owner: L 'I'll d-A Property Address: 3.:;;j if} < Contractor License No.: Company: (! . L 00""- , s. (;>("M.c ST Phone: D 0 3 . 'I "':!if .oj 7' i!>" Phone: OW:-;ERlCONTRACTOR SIGNA TIIRE OF t'~D[RSTANDI:";G Al'OD AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Cit)' of Wheat Ridge or covenants, easements or restrictions afrecord; that all measurements sho....'J1, and allegations made are accurate; that 1 have read and agree to abide by an conditions printed on this application and that I assume full responsibility for compliance y,ith the 'Wl1eal Ridge Building Code (U.B.C) and all other applicable Wheat Ridge Ordinances, for work under this pennit. (O\\'''ERXCONTRACTOR)SIGNE~a-:; f. ~~ATE (/;{;.. 0-, (OWNER)(COl\'TRACTOR): PRINTED DATE Construction Value:S Permit Fee:S Plan Review Fee:S Use Tax:S Total:S /7 <'0.00 DESCRIPTION: /-1;J.a -;"d"I1IC- R-lCf'c-A-C!..t:. ..;z de ~1llR,4'lV <=- TD .3 &, A \"L<C'" (t:, t,.J,'" s: pO,,"-"- L 10>-'$ 'S \ ..(.. ~ c>? ,~ ~t><.J"i.0 u.J 0 IY <:Lej../ Ui oo~e'" po'>. ,..r w BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approvat: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residentiat Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) Thls pennit WIS issued in accordance with !he prn,,;sions set forth in your application and is .subjeCll:O the laws of me Stale of Colorado and 10 the Zoning Regulations alld Building Codes Of\\'heal Ridge, Colorado or allY other applicable ordinances of the City. (2) This pennit shall expire if(A) the won: authorized is nol commenced within sixty (60) days from issue dale or (B) the bu.ilding aulhorized is suspended or abandoned for a period of 120 days. (3) If this pennit expires, a new permit may be acquired for a fee of one-half the amount nomlally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonmenl has noI exceeded one: (I) year. If changes have been or if suspension or abandonmenl exceeds ooe (I) year. ful1 fees shall be paid for . new penniL (4) No work of any manner shall be done that will chanse: lhe natural Oow of waler causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hOlm in advance for all inspections and shall receive wrinen approval Otl inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall nol be construed to be a pennit for, nor an appronl of, any \.iolation of the provisions of the building codes or illY other ordinance, law. rule or regulation. Chief Building Inspector COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 15584 Date: 5/23/2003 Property Owner: LINDA LOOMIS Property Address: 3285 CHASE ST Contractor License No. : Company: Phone: 462-5936 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Whe t.Ridge . an es, r work under this permit. (OWNER)(CONTRACTOR) SIGNED rh.!:'c' DATE ~1.~17/&>3 Total: $275.00 $30.55 $0.00 $5.50 $36.05 Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description : REPLACE CHAIN LINK FENCE WITH 6'-0" VINYL FENCE AND WOOD GATE BUILDING DEPARTMENT USE ONLY ZQillng CQirmt~r)l$: Approval: TRC Zoning: R-1 C lilulldiI\VllI9mment$~ Approval: BG ,.....j.<. ""',' ,'.'..""'.'>,,,'-,....,..,:., p.\lRWi Work$;~mments: Approval: Occupancy: Walls: SIC: Sq. Ft. : OKAY 5/21/03 Please Note: Owner I contractor is responsible for locat~'''g propert.y lines and constructing improvements aceo: jing to tOo approved plan and required development 'tand",ds. The City is not responsible for inaccurate infomlation submitted within the plan set and any construction errors resulting from inaccurate information. OKAY 5/21/03 Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval : Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge. Colorado or any other applicable ordinances of the City (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one.half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a it or the ap roval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions uil In any other ordinance, law, rule or regulation. COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) . APPLlClTION Property Owner: L /Nd r1 (! /0""""" S Addr ~ "" b:) {! (-43 e.. <,,\, Property ess: --'~, 0 Contractor License No.: Company: Building Permit Number: 1'>5Z3 r . Dare:~;Va? Phone: ~ Phone: 00;l) - fro":l- -::'-9 ~ OWNERlCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, Construction Value:$ B 7S.00 and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or Permit Fee: $ .:Jt? 5' r covenants, easements orrestrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this Plan Review Fee:$ application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicable Wheat Ridge Ordinances, for work unde,r Use Tax:$ .1'"..5"'0 ::::ONTRACTORJSIGNED t; ,', JlcP c)f~o.3 Total:$ ~~.()5 DESCRIPTION: I2tLfl-IlCL'€. €.-9-.$,'v/p (It\AM "-'rll< (9,v,A,L-Le....'j S, .t e. of-. ('Rbpl2-1L"'7 l/U I~ 101 1/ I ^'Y'r /A~.A.k - DANe L---S. <>I- I'" S 'rA-&L ~ '" Cl ..\ 'e tV (" ~~ e ,-(0) /'r' .AI. f::;. r ~ of< N~ 0 r "rite.. \...0" '$ €:.... BUILDING DEPARTMENT USE ONLY ZONING COMMEfIITS: ~~ _ \ Appro.val: ~ a ("V'( Zomng: tz. tc- 0"\ BUILDING COMMENTS: d Approval: ,.;7, c;., 5'/.;zrfp;,. ~./:: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Electrical License No: Company: Plumbing License No: Company: Expiration Dare: Approval: Expiration Date: Approval: Expiration Date: Approval: SIC: Residential Units: Mechanical License No: Company: (I) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if(A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this pennitexpires, a new pennit may be acquired for a fee of one-half the amountnonnally required, provided no changes have been orwm be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a newpennit (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) ContractorshallnotifytheBuilding Inspectortwenty-four(24) hours in advance for a1linspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. ~ector ~Z ~t- '\ I{ /(~'I , f"+_L ..,,-'-'- '" ( GA~(.;,e ( 'I ( ~ ( ( \ l ( ( .----- I f: , .? <- c ~J>, ':::> ~ ---,-----~._~._--- - kOL:>::' 'C..... c..... _-.,. _ ....'--"" ._~ 'S'\ ...------..-- '---- '-- ......,-- - ~ / /,~c.>;;',Jt,A./f> r ~~ I Q(f.A-'..( '" //1(/'<: k /-..~<'- c:;x..:+tN <. 1 ~ A-'.J t:..- INK t.>>,-r-\.- f' P. \ .It're.--{ f/rrleLS. r \ \ (~,"~<. ~'~'~~ t f 12-e..f\.-A~e e;-x.\5riN(. CG-..,;,.,^,I.,rlK.. ~ Fe...f\fC!..e- C!JN ....--tLe ~ W ,,\ & / fR.e.FAi3 if wy <.. p~,... ek S ~ I .r , . AlIe, . t.n · I,#~tf:l.-L 61 .. t<7oacl-~ t';AT"C- DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number: Date: 14338 8/15/02 Property Owner: LINDA LOOMIS Property Address: 3285 CHASE ST Contractor License No. : 20743 Company: TEK Roofing Services, Inc Phone: 462-5936 Phone: 303-788-1432 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat RU;lge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ~~ . ~ATE ~/S-:. Construction Value: Permit Fee: Plan Review Fee: Use Tax: Total: $1,900.00 $66.20 $0.00 $22.80 $89.00 Description: REROOF WITAMKO 3 TAB BUILDING DEPARTMENT USE ONLY --- Approval: Zoning: Approval: Occupancy: Roof: Stories: Walls: Electrical License No : Company: Plumbing License No : Company: Expiration Date: Approval: Expiration Date: Approval: Use: 1f0i?1~il) SIC: Sq. Ft.: This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. T. he.. ~i~SI nce of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the .E.?io~ ~f t e b. ng codes or any other ordinance, law, rule or regulation. (1) (2) (3) (4) (5) (6) Residential Units: Mechanical License No : Company: Expiration Date: Approval: DEPARTMENT OF PLANNING AND DEVELOPMENT BUll..DING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPUCltTfON Building Pennit Number: Date: Pr Own /. D- /~a.-"'"1/S operty er: ?-"'/ - ~ <-. . ~ ,- C'.. r/-'" ..-<!: Property Address: S 2.. . ~ Contractor License No.: 2. ~ 7 "I" Company: //17,. ''r Rc>= r/ A.> c. sr- ,,~ :< Phone: '-I t-2.- $-<73 c::. Phone: 3 <> ~ - 7 "" b-, ,/<[? :L OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: "/ Permit Fee: Plan Review Fee: ~~03-.-&::..-"~ I hearby certify that tho setback distances proposed by this pennit application arc accurate, and do not violate applicable ordinanc~ rules or regulations of the city of Wheat Ridge or covenants, easements or ~ctions of record; that all measurenuurls shown. and allegations made are accurate; that I have read and agree to abide by all conditiona printed on 1bia applicatiOIlS and that I aaaume full rospoosibiJity for complianoc with tho WhClit Ridge Bo.iIding Code (U.B.C) and all other applicable Whootltidge ~ ~ wo.rk undor1bia ponnit. (OWN!!RXCONIl<ACI'OR),s~~~- DATE ''is--1 ~~"" 2-- TTc:!p T~v' Total: Description: tA Fe /I. C> c> r ~, T't, rh..,J---(C::> ~ /,N)3 BUILDING DEPARTMENT USE ONLY I_E.';':{~}: ..... h'"' .."........."Jl ", ::,~.,....~:. ~.: ............. ...~~~: SIC: Sq.Ft.: ApproVal: Zoning: RB'j!&A!S.: Approval: iIiI.~if.I~Ii: Approval: Pccupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: . Plumbing License No: Company: Mechanical License No: Company: Expiration Date: ApproVal: Expiration Date: Approval: Expiration Date: Approval: (1) This pemtit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building CodD ofWhcat Ridge, Colorado or any other applicable ordinancOll of the Cit'. (2) This pmnit !hall expire if (A) tho work auth.orizcd is not camm.cnced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) Jfthis pmmit ~0Il. a now pormit mJ:'f be acquired for a fee of anc-halfthe amount no.anally required, provided. no changes have bCQD. or will be madoin tho origi:nal plans and specifications and any su.spmsion or abandonm.ent has not exceeded ono (1) year. If changes Mvc boen or if suspension or abandonm.ent elCCCCds one (1)ycar. fullfees Ihall. be paidfor anewpeonit. (4) No worlc. of any IIllInnU shall be dono that will ch.mge tho natural flow of water cmsing a drainage problem. (5) C~ shall notifY the Building Inspector twenty.four (24) h()11[!l in advance for all inspectians and shall receive written approval on inspection card before procccdiogwitb. suCc:euive phases of tho job. (6) The issuance of a pemrit or the approval of drawinp and sp=cificatians shall not be construed to be a pcanit for, nor an approval of, anyviolation of the provision.s ofthc building codes or any otberotdinancc, law, IUle orregula.tion. Chief Building Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 12426 eUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date: 7/10/01 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: Property Address: 3285 CHASE ST Contractor License No.: 19016 Company: Tops Heating & NC OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone: 671-9118 Phone: 733 7586 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibilit for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable wne%ances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED I , DATE ';:z./6-01 Total: $120.00 $23.50 $0.00 $1.80 $25.30 Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description: INSTALL A 75,000 BTU FURNACE JtcSgg3J BUILDING DEPARTMENT USE ONLY SIC: Sq. Fl. : -- Approval: -..... Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before pro 'jng with successive phases of the/Db. (6) Th ss 7ffnce fa mit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions . e il' or any other ordinance, law, rule or regulation. ~hi~f BUildiriC DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: Property Owner: Property Address: Contractor License No. : Company: i~ 3 { 5'5- APPUC.(\TID N G~ C~ sJ Phone: (.7/- 0, J / fr fOfS. H. i/ fl-L Phone: 733- TJ(y(, OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Use Tax: ;2-000 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED --;:;-7 Ae~ DATE 77~9'CJ/ be"c.d'O\.iJ t) 7J;C'C'CI {JIU &~~ Total: Use: Description: BUILDING DEPARTMENT USE ONLY ~~ Approval: Zoning: SIC: Sq. Ft.: Approval: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) (2) (3) (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of VVheat Ridge. Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required. provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural now of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. Chief Building Inspector