Loading...
HomeMy WebLinkAbout3605 Dudley Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:`' r ke- Job Address: lb.)� )Pk./ ' Permit Number: ❑ No one available for inspection: Time : � &Pm Re -Inspection required: Yes `No When corrections are complete, schedule re -inspection online. Date:' ('I - ,67-; Inspector: Ah DO NOT REMOVE THIS NOTICE 9100 W Jewell Ave Lakewood, CO 80232 CIL ENGINEERING, INC. 720-440-9450 www.diengineer.com 1/22/2021 FJ Progressive P.O. Box 12446 Denver, CO 80212 RE: 3605 Dudley St. Wheat Ridge, CO 80033 Foundation Observation: Caissons Please provide this letter as proof of the following onsite observation on January 20, 2021. Below is a summary of the observations made: • Caissons — There were (10) caissons that were observed. The caissons had a diameter of 8" and were 45" deep. There were 2 ##4 rebar inside each caisson. The diameter and locations of the holes appeared to be in accordance with the plans. If you should have any further questions, please feel free to contact me at (720) 440-9450 or kmorales@dlengineer.com. Sincerely, Kevin Morales Under the direct supervision of, Daniel LeMier, P.E. Job # 2020-8768 Digitally signed Daniel by Daniel LeMier at LeMier2D02e:1.01.22 15:57:24 -07'00' p Ri=v, Cy ••` YJ� U :O' 35393 N City of Wheat Ridge Residential Deck PERMIT - 202002679 PERMIT NO: 202002679 ISSUED: 01/19/2020 JOB ADDRESS: 3605 Dudley St EXPIRES: 01/18/2021 JOB DESCRIPTION: Construct deck and remodel garage - 350 sq ft total *** CONTACTS *** OWNER (303)422-9034 GONZALES DEBORAH MARSHALL GC (970)846-0989 FRANK CEFARATTI 190222 FJ PROGRESSIVE *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 81000.00 FEES Total Valuation 0.00 Plan Review Fee 112.19 Use Tax 168.00 Permit Fee 172.60 ** TOTAL ** 452.79 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. For one- or two-family dwellings, the first twenty-five feet ( 2 5 ' ) of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. A right-of-way permit may be required; contact Public Works Department at 303-235-2861. Landscaping removed or damaged during construction must be replaced prior to final inspection. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Deck PERMIT - 202002679 202002679 ISSUED: 3605 Dudley St EXPIRES: Construct deck and remodel garage - 350 sq ft total 01/19/2020 01/18/2021 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include al entities entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any pplicab e code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 01/19/2020 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. no change to valuation From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Accessory Structure (Garage, Shed over 120 sq ft, Gazebo) Date: Monday, December 28, 2020 12:47:57 PM Residential Accessory Structure (Garage, Shed over 120 sq ft, Gazebo) THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 3605 Dudley St Wheat Ridge 80033 Property Owner Name Frank Cefaratti Property Owner Phone 970-846-0989 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" frank@fjprogressive.com WR Permit ADDlication - Dec 2020.iDea CONTRACTOR INFORMATION Contractor Business FJ Progressive Builders Inc. Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) 190222 0118II-T,10816I:1' Contact Email Address fjprogressive@gmail.com for Questions/Comments Retype Contractor fjprogressive@gmail.com Email Address DESCRIPTION OF WORK Detailed Scope of Work - Example: Detached Garage with Electrical; Unconditioned shed Square Footage of Accessory Structure Engineering Letters and Other Letter Size Attachments Construction Plans scanned on 11'x17" or larger Project Value (contract value or cost of ALL materials and labor) Addition of deck and garage remodel 350 2020-8768 PLANS 3605DUDLEY 12-22-20.odf Field not completed. 8000.00 ok bf 1/18/21 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Frankcefaratti Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. AA I 5Beert[raffRomfB� [08@302 � 003)382 1175 Inc 1066)699a2l January 11, 2021 com 970 845 0989 Ms irresto;atron now corturchurc ted on belcalf of aI for flue ex clusevef use of FJ concentofBouRcerEfornmeramentalho ancesic are encountered confect us chGcu ? er � , CathyNaccaratoCO mn � Bunting Infector : Houlder Euviroummtal lnr. 5Beer�RoAB� C08@3@2 � 0@3)382 1175 Fax 1066)699a2l MR ADDITION ON GARAGE 3605 NoraU ley 5heel Vlhsa v ,ammo muroductism CMehannoseoffine Cnmt(ACva content oos(PAK a�oPoh e oAgemy(PA)for ry o(bmaobtmnoao�ngre e mpn Thea se categorres an the nual note m mosatort ACES Ease Deacons ACES nt 0 w pd w" ofia ,Mtmma;'�aco N:w rato ; C;u'�cmueaN: hapten �Mm m no noo`Ms. �a��nret eie:`. mg g "�ne. campnag sunbathe. mr s, thae c3x hw rn, as rn:M� lest �aiyR a`w ab tight' �m�lM man,w � .mama mm erect deencuA Me or there crals an accosted remnants al vatuas based on an earchuncon of the mInconoweed bunmhg blsmat�mmi�oCMiDarmagedficalesublaring ACES 3 m°danche seACMwNh ACM A.eam. i re=srmarhwAar�s• Houlden EuviroummW l c. 5Bew�RoAB� C08@3@2 araw=anamom,. endo•%) �ETA i,`="° ,au,t,re Baa beforeapirritisrall orrsao orswo rn;-m basem�a aaromai'sa��w`"m=n,�,; re�ra,a%na a�,moea`;a� anmss.sr puaimewmmvao Qo& � s aae,ao. m,m,am, vrrnrecla aiiiincatrins ay cwom An� ac blww ew ise�ieema°moam�oegmtn&moetm�remm ;� re itu`m om�m onna narementwject, s llo.�.�`s-&yea e nitificatrinregas,m�� ,.aw. �xBE mUpniaaam;noMagmambl n`Inctlym�mmoetm�ot maum4v� sekctedone r re& ercomem=ei .s ,m,ma mom a mm,a&m li w r a.eam. i a=smr'rewaar.>as• xaruaw syr^ m e• Houlden Euviroummtal lur. � 0@3)382 1175 Fax 1066)699a2l eacwgguage inemotlro tewdimmel amuemme mwmdom,jwa cmgbWoafioxredwa. s 0 PwwrMg mese fMcros above ere anar]a Please contart Boccoler E=mmoM Inc I you have y que stromor come rm mgaxc gtM Io V� IojMaron ect Maaeger Actvmc L a*spry*Fuu1Avivting* Holuvw shNi^ m^e• V C Ln c 0 0 > v w In N 0 > 0 C: c N O 0 0 000 a O E c U V v c� E. O V u C N 4' O� E� t 0 m> o E 0 - m Z) rn U> m r O F- L) U U a a N J LU U U N L O U i a� 0 E Cf J O U Q c Q O C O o U c En o -' y v Z Y � � c O m O U N L d :3 Z3 L (n 0) y U 0 a x N Q - E � L O w o U_ T C Q w O w O N a a N 0 C: W ZC O N m = U E Q in CN m NN O N o _ N Q�CR) `> a) m O-p m L N 00-0000 Q -C o Z o 0 CL Q O +) m a oa. a W fl _0 c Q 0- W z O N ED 0 U N N E w 7 0O 0 x x x N x O U w U w U N L O U i a� 0 E Cf J O U cYd r� rZ a m N Lr) 0 0 N N U d ❑ m N N 7 F w X w m D a 517- 72' 8" 5' 2" 13'_ 8" 3'-8" REVISIONS DATE 1 2 3 Mie v v (N) GARAGE — — — — — — — — — — — — — — — — in (E) HOUSE (N) DECK N 12' 14' I I I I FLOOR PLAN 1/4" = 1'-0" ZQ J a O 0 N O N r r 31tl0 O J LL I AS NO3HO Q A8 W � O a � � N O�vl OC ZWYQ�Nld Wheat Ridge Z°oao LU Building Lamson N 0 �W Zoaww WMdc* a Z W �• RE G1sq 0 Q Z o LU o <2-P� OO , •� BIH • ' •. Cc g 51219 JOB NO. 20208768 �O�•. �•��� SHEEP °• `' NAL EAG 0 AoF 5 a m N Lr) 0 0 N N U d ❑ m N N 7 F w X w m D a REVISIONS DATE 1 2 3 EAST ELEVATION WEST ELEVATION 1/4" = 1'-0" 1/4" = 1'-0" 111111 11 IT 11 11 IT 11 11 IT IT 11 111 ��I IT 11 11 IT 11 11 IT 11 11 IT 11 1111 11 1111 T 11 111 P1, L, 14 11 11� 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111 ul -flfl 11 1 Ifl 11 jfl 11 lu�L 0 4� 0 Lj fV SOUTH ELEVATION o n 11 1 IT 11 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 111111 111111 11111 11111 11111 11111 11111 11111 IIT 11 111 11 111 Z T O 31tl0 F W J W � J 03HO I I IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 11 IT 11 11 IT 11 11 Q 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 1 1 AS v1 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111-1 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111-1 11 111-1 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111-1 11 111-1 11 11 IT 11 11 IT 11 111-1 11 11 IT 11111"1 11 111 1 11 111 1 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 111111 111111 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 111111 111111 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 111111 111111 111111 11 IT 11 11 IT 11 11 11 1 11 1 I IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 IILL[11F�Ihll 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111111 111111 1 W � O 11 11 If I I I IT 11 11 1111 11 IT 11 11 IT 11 11 IT 11 11 IT 11 11 1111 11 IT 11 11 IT 11 11 IT 11 11 1111 11 1111 11 IT 11 11 IT 11 11 IT 11 11 IT 11 111 T 11 11 1111 11 IT 11 11 1111 111 T 11 11 IT 11 11 IT 11 11 IT 11 11 IT 11Q 1, N Ovl CRY o 1320 J WW Z ZO Wheat Ridge 119 Building Drown (N) ROOF TO MATCH (E) N � Z LU o V �Qwo0W Z�OaLu WWpOt7 ZIP SYSTEM Z3 C J NORTH ELEVATION p0 REGI z O 3 w o 1/4.. = 1.4 O�P� BIH • s�cc W 911 - Mel 51219 JOB NO. 2020-8768 �O�•. �•��� SHEEP AIA °• °' �SS�ONAL E�G OF 0 5 7/16" OSB. 2x6 STUD @ 16" o.c. OR SHEATHING PER SHEAR WALL SCHEDULE z io CURB AS NEEDED 6 • • li I II MESH PER PLAN z a. #4 VERTICAL @ 24" o.c. LAP 24" MIN (4) #4 (2) TOP, (2) BOTTOM 8" 3" CLR. TYP. (N) BLOCKING SPLICE (N) RAFTER TO (E) EAVE M/16 OSB MATCH (E) EAVE OR (N) 2x6 @ 24" o.c. (N) BLOCKING --\ L�� "-(N) H2.5T V = V-0" #4 HORIZONTAL (E) SHEATHING 1" = 1'-0" (E) TOP PLATE (N) BEAM PER PLAN DEMO (E) WALL STUDDS #4 HORIZONTAL REBAR REBAR #4 VERTICAL � #4 VERTICAL ° AT INTERIOR ° AT INTERIOR OF BEND OF BEND Q a LAP 24" MIN LAP 24" MIN TO EXTERIOR REBAR TO EXTERIOR REBAR TYP CORNER REBAR LAYOUT 1" = V-0" (E) RIM BOARD 2018 IRC - Wall Construction TahIP Rrn7 V11 Tvnirni FactPninv SrhPrhjIP ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AN D TYPE OF FASTENER SPACING AND LOCATION 2x6 PT @ 2x6 PT LEDGER Blocking between ceiling joists or rafters to top 16" O.C. 1 plate Toe nail 3-3" x 0.131" nails OC 4x10 PT z 2 Ceilingjoists to top plate Per joist, toe nail 3-3" x 0.131" nails Ceiling joist not attached to prallel rafter,laps 3-16dcommon (31/2"x0.162");or 3 over partitions co ABU44 4 Ceilingjoistattached to prallel rafter (heel joint) Table R802.5.1(9) Face nail Y4" SLOPE 3-10d common (3" x 0.148"); or Face nail each rafter 4-3" x 0.131" nails 6 Rafter or roof truss to plate 3-10d common nai Is(3" x 0.148"); or 2 toe nails on one side and 1 toe nail on 4-3" x 0.131" nails opposite side of each rafter or truss LUS26 LUS26 Roof rafters to ridge, valley or hip rafters or roof Toe nail 4-3" x 0.131" nails 7 rafter to minimum 2"rid ridge g 4" LEDGERLOK - 3-3" x 0.131" nails Wall @ 16" o.c. I I-III -III 16d common (3 1/2" x 0.162") 24" o.c. face nail 8 STAGER I I I - I-II Stud to stud and abutting studs at intersecting TOP & BOTTOM I -III z wall corners (at braced wall panels) 16d common (3 1/2' x 0.162") 16" o.c. face nail 30 Built-up header (2" to 2" header with 1/2" spacer) 16d common (3 1/2" x 0.162") 16" o.c. each edgeface nail 11 (2) #4 REBAR VERTICAL 4-8d common (2 1/2" x 0.131") Toe nail 3" CLR TYP 12 Top plateto top plate 3" x 0.131" nails 12" o.c. face nail 1" = 1'-0" (E) TOP PLATE (N) BEAM PER PLAN DEMO (E) WALL STUDDS #4 HORIZONTAL REBAR REBAR #4 VERTICAL � #4 VERTICAL ° AT INTERIOR ° AT INTERIOR OF BEND OF BEND Q a LAP 24" MIN LAP 24" MIN TO EXTERIOR REBAR TO EXTERIOR REBAR TYP CORNER REBAR LAYOUT 1" = V-0" (E) RIM BOARD 2018 IRC - Wall Construction TahIP Rrn7 V11 Tvnirni FactPninv SrhPrhjIP ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AN D TYPE OF FASTENER SPACING AND LOCATION Roof Blocking between ceiling joists or rafters to top 3-8d common (21/2" x 0.131"); or 1 plate Toe nail 3-3" x 0.131" nails 2 3-8d common (2 1/2" x 0.131"); or 2 Ceilingjoists to top plate Per joist, toe nail 3-3" x 0.131" nails Ceiling joist not attached to prallel rafter,laps 3-16dcommon (31/2"x0.162");or 3 over partitions Face nail 4-3" x 0.131" nails 4 Ceilingjoistattached to prallel rafter (heel joint) Table R802.5.1(9) Face nail 5 Collar tie to rafter, face nail or 11/4" X 20 ga. ridge strap to rafter 3-10d common (3" x 0.148"); or Face nail each rafter 4-3" x 0.131" nails 6 Rafter or roof truss to plate 3-10d common nai Is(3" x 0.148"); or 2 toe nails on one side and 1 toe nail on 4-3" x 0.131" nails opposite side of each rafter or truss 3-10d common (3 1/2" x 0.148"); or Roof rafters to ridge, valley or hip rafters or roof Toe nail 4-3" x 0.131" nails 7 rafter to minimum 2"rid ridge g 2-16d common (3 1/2" x 0.162"); or End nail 3-3" x 0.131" nails Wall 16d common (3 1/2" x 0.162") 24" o.c. face nail 8 Stud to stud (not at braced wall panels) 3" x 0.131" nails 16" o.c. face nail Stud to stud and abutting studs at intersecting 3" x 0.131" nails 12"o.c.face nail 9 wall corners (at braced wall panels) 16d common (3 1/2' x 0.162") 16" o.c. face nail 30 Built-up header (2" to 2" header with 1/2" spacer) 16d common (3 1/2" x 0.162") 16" o.c. each edgeface nail 11 j Continuous header to stud 4-8d common (2 1/2" x 0.131") Toe nail 16d common 3112"x0.162" 16"o.c.face nail 12 Top plateto top plate 3" x 0.131" nails 12" o.c. face nail Doubletop plate splicefor SDCs A-132 with seismic Face nail on each side of end joint 8-16d common (3 /z" x 0.162"); or 13 braced wall line spacing < 25' (minimum 24" lap splice length to side 12-3" x 0.131" nails of end joint) Bottom plate to joist, rimjoist, band joist or 16dcommon (31/2"x0.162") 16"o.c.face nail 14 blocking (not at braced wall panels) 3" x 0.131" nails 12" o.c. face nail Bottom plate to joist, rim joist, band joist or 2-16d common (3 1/2" x 0.162"); or 2 each 16" o.c. face nail 15 blocking (at braced wall panels) 4-3" 0.131" nails 4 each 16" o.c. face nail 4-8d common (2 1/2" x 0.131"); or Toe nail 4-3" x 0.131" nails 16 Top or bottom plate to stud 2-16d common (3 1/2" x 0.162"); or End nail 3-3" x 0.131" nails 2-16d common (3 1/2" x 0.162"); or 17 Top plates, laps at corners and intersections Face nail 3-3" x 0.131" nails Floor 3-8d common (21/2" x 0.131"); or 21 Joist to sill, to plate or girder 3-3" x0.131"nails Toe nail Rim joist, band joist or blocking to sill or top 8dcommon (21/2"x0.131");or 22 plate (roof applications also) 3" x 0.131" nails 6" o.c. toe na i I 3-16d common (3 1/2" x 0.162") 26 Band or rim joisttojoist 4-3" x 0.131" nails; or End nail 4-3" x 14 ga. staples,'/16" crown 20d common (4" x 0.192"); or Nail each layer as follows: 32" o.c. at top and bottom and staggered. 24" o.c. face nail attop and bottom 27 Built up girders and beams, 2-1 nch lumber layers 3" x 0.131" nails staggered on oppositesides AND: 2-20d common (4" x 0.192"); or Face nail at ends and at each splice 3-3" x 0.131" nails 3-16d common (3 1/2" x 0.162"); or 28 Ledger strip supporting joists or rafters 4-3" x 0.131" nails At each joist or rafter, face nail 29 Bridging to joist 2-10d (3" x 0.128") Each end, toe nail SPACING OF FASTENERS ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER Intermediate Edges (inches) supports (inches) Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] s 6d common (2' x 0.113") nail (subfloor, wall) 30 /s 1z 6 12 8d common (2 112" x 0.131") nail (roof) 31 19/32" 1" 8d common nai 1 (2 112" x 0.131") 6 12 10d common (3" x 0.148") nail; or 32 1 1/s" 1 1/4" 6 12 8d (2 112" x 0.131") deformed nail Other wall sheathingg 35 1 d /2" gypsum sheathing 1 1 /2" galvanized roofing nail; staple galvanized, 7 7 1 1 1 /2" long; 1 /4" screws, Type W or S 36 5 d /g" gypsum sheathing 1 3/4" galvanized roofing nail; staple galvanized, 7 7 s s 1 /s" I ong; 1 /s" screws, Type W or S Wood structural panels, combination subfloor underlayment to framing 37 3/4" and less 8d common (2 1/2" x 0.131") nail 6 12 38 '/6" - 1" 8d common (2 1/2" x 0.131") nail 6 12 39 1 1/s" 1 1/4" 10d common (3" x 0.148") nail 6 12 SHEAR WALL KEY: KEY PLYWOOD FIELD EDGED 1 ZIP SYSTEM R -SHEATHING (R-6) 8d @12"o.c. 8d @ 4" o.c. 2 3/6 OSB 8d @ 12"o.c. 8d @ 3"o.c. 3 ZIP SYSTEM R -SHEATHING (R-6) 8d @ 3"o.c. 8d @ 3"o.c. 4 Y2' GYPSUM 1Y2' TYPE W OR S @ 7"o.c. 1Y2" TYPE W OR S @ 7"o.c. 5 Y2' GYPSUM 1Y' TYPE W OR S @ 4"o.c. 1Y' TYPE W OR S @ 4"o.c. NOTES: • ALL EXTERIOR SURFACES, EVEN THOSE ABOVE AND BELOW OPENINGS, ARE TO BE CONTINUOUSLY SHEATHED WITH A MINIMUM OF SHEAR SCHEDULE 1 UNLESS OTHERWISE NOTED ON THE PLANS. • ALL NAILS REFERENCED IN THESE DESIGN DRAWINGS ARE TO BE COMMON WIRE NAILS UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. • THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FASTENING OF ALL BUILDING ELEMENTS PER TABLE R602.3(1). THESE TYPICAL FASTENING REQUIREMENTS WILL BE OMITTED FROM THE DRAWING FOR CLARITY. 0• r 0 0 N 0 � N Z r ~ T U w Z J 31tl0 ZQ Ov oJ UAs d J 03HO r FN W 0 O a LLI cc Go N Ovl W di Z W -low OoGCO N 0 Z � o V 13 0 in W LU W30oz Z vo W C• R EG1,q 00 O W V c ccs 00•y�;ip W g 51219 JOB NO. �O�•. 2020-8768 (/� ••�v� •G� SHEET • SSS/ONAU E� 31.0 of 5 1 1/2" AB TYP REVISIONS DATE + — foundation inspection is S1.0 8" EMBED MIN.O. 4' MAT 2 — a — required by the city inspector DOWEL (4) START 8" FROM ALL 8" prior to pouring concrete #4 REBAR CORNERS 4" CONCRETE SLAB INTO (E) RENF. 6x6 AND DOOR "fO FOUNDATION TYP. w/ w1.4xw1.4 TYP JAMBS - MIN (2) PER PLATE 6'-8" 2 Sl.o DEMO TOP OF FOUNDATION WALL DOWN TO BOTTOM OF SLAB (E) HOUSE CID 2 S1.0 O SIM �N O F"� CO /777777777777777777777 IIF71117111 FOUNDATION PLAN 3 S1.0 5, 4 1/4" = 1'-0" 6' 13, 1" 2 S1.0 1 1 1 2 SS1..0 L L J J b — — — — — S — — — — — — — — ?J r L r � J � Z O o o� J , C9 Z Z iz v - Vr r J d Q T 31tl0 ` r 4x6PT J r r O LLL Y ¢ U ❑ w Z I L r J � p_ rD OZ LL Q J 03H0 L F JL x J NLL JL J O a Aa L r J � 2x10PT J (E) HOUSE � L r L J J J J on W O r a cc a L J J z!:0 I r 0 V L J J , a j W W V x 2 S1.0 SIM L ; J ; J CRY of Zoe' - O WNF a -� dr dr , M 3 X- a Wheat Ridge L J 2x6PT @ 16"o.c. TYP J (J� BUHding DINISon N 0 N L r J J Z; 0 V- awo ¢ W V CP Z L r J � � Z70041 o_ RE G149 O 'iJ Z O W c L J L JL JL JL JL JL JL JL JL JL ROOF AND DECK FRAMING PLAN �PpO BIH ' `�� •y•. W ! e J 4x10PT 51219 JOB NO. 2020-8768 2 S1.0 - �0��. SHEET ��� 0. 0 `' �SS�ONAL EAG SoF 7 5 tL LO N tii 0 N O N [V N d U 0 m d H 0 LU <n J M tL Design Criteria INDEX: 1. Building code: C1.0 GENERAL NOTES / SITE PLAN 1.1 Model building code: 2018 IRC, 2018 IBC A1.0 FLOOR PLAN City of Wheat Ridge Local Amendments A1.1 ELEVATIONS 2. Dead loads: S1.0 DETAILS 2.1 Roof total 20psf S1.1 FOUNDATION PLAN / 2.2 Floor 12psf ROOF AND DECK FRAMING PLAN 2.3 Walls 10psf 3. Live loads 3.1 Residential 40psf 3.2 Roof 20psf 4. Snow loads 4.1 Ground Snow load pg 30psf 4.2 Roof Snow Load = 30psf 5. Handrail 5.12001b point load 6. Wind Design Data 6.1 Exposure Category C 6.2 Basic Wind Speed Vait = 135 mph 6.3 Occupancy Cat. Iw = 2 7. Seismic Design Data 7.1 Risk Category II 7.2 1e = 1.00 7.3 Ss=0.22 ; 51=0.06 7.4 Site Class D (Stiff soil) 7.5 SDC = B General notes: 1. Construction documents are valid for a single use at the project location and shall not be reused, copied, or reproduced without written approval of the registered design professional in reasonable charge. 2. General notes and typical details are provided as a supplement to the construction documents and apply where specific notes and details are not available. Specific notes and structural details shall take precedence over general notes and typical details. Structural requirements shown in the framing plans and in the structural shall take precedence over structural notes indicated in architectural sections. 3. Printed dimensions shall take precedence over scales shown on construction documents. The registered design professional in reasonable charge does not warrant the accuracy of scaled dimensions. 4. Approval by the inspector does not imply approval by the registered design professional in reasonable charge. Structural specifications that are unclear or ambiguous shall be referred to the registered design professional in reasonable charge for interpretation or clarification. 5. The contractor is responsible for the methods, means and sequence of all structural erection except when specifically noted otherwise in the construction documents. The contractor shall provide temporary shoring and bracing, providing adequate vertical and lateral support during erection. Shoring and bracing shall remain in place until all permanent members are placed and all final connections are completed. 6. The contractor is responsible for standard connections unless notes otherwise. The contractor shall obtain additional assistance from the registered design professional in reasonable charge for all non-standard connections. 7. The contractor agrees that, in accordance with generally accepted construction practices, the contractor will be required to assume sole and complete responsibility forjob site conditions during the course of construction of the project, including safety of all persons and property. This requirement shall be made to apply continuously and not be limited to normal working hours. The contractor further agrees to defend, indemnify and hold owner and engineer harmless from any and all liability, real or alleged, in connection with the performance of work on this project, exempting liability arising from the sole negligence of engineer. Concrete 1. Concrete materials, quality control and construction shall comply with ACI 318-14. Special inspections shall be evaluated in accordance with ACI 318-14 R5.6, 5.8 and tested in accordance with ASTM C172, C31. Compressive strength (minimum specified at 28 days) 1.1 Footing 3500 psi 1.2 Slab 3500 psi 1.3 Walls 3500 psi 2. Materials 2.1 Cements (ASTM C 150) Concrete exposed to freezing and thawing or deicing chemicals shall conform to the maximum water-cementitious material ratio and minimum compressive strength requirements of ACI 318-14 table 4.3.1. 2.2 Aggregates (ASTM C 33) nominal maximum size of course aggregates shall conform to (ACI 318-14 3.3.2) 2.3 Water used in mixing concrete shall be potable and clean. ACI 318-14-3.1.1-2) 3. Steel 3.1 Deformed Bars: fy =60 ksi (ASTM A615) 3.2 At the time concrete is placed, reinforcement shall be free from mud, oil, and other nonmetallic coatings that decrease bond (ACI 318-14 7.4.1) 4. Minimum Concrete cover (ACI 318-14 7.7.1) 4.1 Concrete cast against earth: 3 inches 4.2 Concrete exposed to earth or weather: 5.2.1 No. 6 or larger 2 inches 5.2.2 No. 5 bars, W31 Wire, or smaller: 1.5 inches 5. Formwork shall conform to ACI 318-14 and ACI 347. Forms shall be removed in a manner as not to impair safety and serviceability of the structure. Concrete exposed by form removal shall have sufficient strength not to be damaged by removal operation. Wood 1. Wood materials, quality and construction shall conform to 2018 NDS. 2. Structural lumber: (2018 NDS) 2.1 Bearing walls:Hem-Fir (HF) Stud (SATM D 1990, DOC PS 20) 2.2 Post: Hem -fir (HF) #2 or better (ASTM D 1990, DOC PS 20) 2.3 Beam and Headers Hem -fir (HF) #2 or better (ASTM D 1990, DOC PS 20) 2.4 Sill Plates Preservative -treated wood 3. Structural composite lumber and engineered wood (2018 NDS 8.1.1) 3.1 Laminated strand lumber 3.1.2 Ex = 1.55E 3.2 Prefabricated wood I -Joist 2018 NDS 9.1.3) 3.3 M icrol lam LVL Ex = 2.0 4. Wood Structural panels 4.1 Roof floor and sheathing: Oriented Strand Board (OSB) (DOC PS 1,2) 4.2 Sheathing shall be manufactured with exterior glue and not less than 4x8 feet, except at boundaries and at changes in framing. 4.3 Wall Sheathing 4.3.1 Oriented Strand Board (OSB) (DOC PS 1,2) 4.3.2 All panel joints in wall shall occur over studs or blocking using 8D nails spaced a minimum of 6 inches at panel edges and 12 inches at intermediate framing. Stager sheathing joints. 5. Joist hanger, column caps, column bases, framing hardware: 5.1 Acceptable manufacturer Simpson Strong Tie 5956 W. Las Positas Blvd., Pleasanton, CA 94588 (800) 925-5099 http://www.strongtie.com 5.2 Substitutions: not permitted. 5.3 Wood connectors on pressure treated lumber are to be corrosion resistant stainless steel or hot dip galvanized hardware. 6. Adhesive: 6.1 Liquid nails heavy duty construction adhesive (In-903/lnp-903) 6.2 Specification ASTM c-557 6.3 Substitutions: permitted. Prefabricated Metal Plate Wood Trusses 1. Prefabricated metal wood trusses shall be designed in accordance with 2018 IRC Section R802.10 and shall conform to the structural specifications and design criteria. 2. The truss designer shell provide a truss package that includes the following items: 2.1 Design drawings of each individual truss (2018 IRC R802.10.2) 2.2 Truss placement diagram for the project (2018 IRC R802.10.2) 2.3 Truss member permanent bracing specifications (2018 IRC R802.10.3) 3. Transfer of loads and anchorage of each truss to the supporting structure shall be approved by the registered design professional in reasonable charge (2018 IRC R802.10.1) 4. Truss members and components shall not be cut, notched, drilled, spliced or otherwise altered in any way without the written concurrence and approval of the registered design professional in responsible charge. Alteration resulting in the addition of loads to any member shall not be permitted without the verification that the truss is capable of supporting additional loads (2018 IRC R802.10.4) Structural Observation 1. The owner shall employ a registered design professional to perform structural observations as defined in 2018 IBC 1702 for those structures where one or more of the conditions stated in 2018 IBC 1710.2 through 1710.3 exist. Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of the structural observations. At the conclusion of the work, the structural observer shall submit to the building official a written statement that the site visits have been made and identify any reported deficiencies which have not been resolved (2018 IBC 1710.0) ZONING SITE PLAN LEGEND PROPERTY OR ZONE LOT LINE - - - - REQUIRED OR ZONE LOT SETBACK 65%/35% ZONE LOT DEPTH LINE ..................................................... SPOT ELEVATIONS AT ORIGINAL GRADE EXTERIOR BUILDING FOOTPRINT ROOF LINE SEWER LINE FFNCF X DECK CONCRETE ••: s�A, City of �WhcatR'd COMMUNITY DEVELCN'MENT APPROVED R�7s; ,Afe6 fair Code Compliance BRANDON F 1/18/2021 Plans Examiner Date validity ut permit: The waame of o permit or gpprovof of plans specificat w 01341 eomputahons shaft not be o petmlt for, or an approve! af, any vialabon w Oily of the provlsiam aj the budding code or of a(W City avdinonces. permits prewerang to give authority to V"Or or eft"el the pra "ons of thaYtdit coda or othtr "noon of the City ahold rot be what EXISTING PROPERTY ADDRESS 4447 N NEWTON STREET DENVER, CO 80211 PRIMARY BUILDING FORM SUBURBAN HOUSE ZONING U -SU -C1 ZONE LOT AREA 5370 S.F. ZONE LOT WIDTH DTH 43 FT (E) PRIMARY STRUCTURE FOOTPRINT 866 S.F. 16.1% (N) GARAGE 576 S.F. 10.7% TOTAL BUILDING COVERAGE 1442 S.F. 26.9% MAX COVERAGE ALLOWED 2014 S.F. 37.5% REAR BASE PLANE ELEVATION (5390.2'+5390.9')/2 =5390.6' Items listed on legend not shown in graphic all work shall comply with 2018 IRC, 2018 IECC, Colorado Plumbing Code, 2020 nec, and The City of Wheat Ridge amendments and policies (b N ON SITE PLANS MUST BE ON SITE FOR INSPECTION --ALL Prallitrai r SUMIM to n _ctlorls Reviewed for Zoning Compliance by the A, City of Wheat Ridge Planning Division APPROVED YVI BY: DATE: December 28, 2020 COMMENTS: Approved with conditions The first 25' of a driveway from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick paver or similar material. Contact Dept of Public Works for ROW Permit 303-235-2861. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Landscaping removed or damaged during construction must be replaced prior to final inspection. SITE PLAN 111=101-01,Digitally signed by Angela S U Date: 17:27:42 -05'00' O N O r n U.] 0 Z r Z 31VI Q a Of w I w Z U.] �s 0 xo3F H� W O a�o�o L - r15 0! a JW W OZ on Z0Lo 0 ZO 1904 aX M3 N � Zoo v in W .J LL1 �Wv0Z WWp.449 ZOO,cZ -1 C Z p W C a 3 2020.8768 SHEET C1.0 OF 5 INSECTION RECORD Occupancv/I INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/forms.aspx?fid=79 INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Wall Sheathing Concrete Encased Ground (CEG) Sewer Service Foundation/ P.E. Letter Mid -Roof',' Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Wall Sheathing Sewer Service Mid -Roof',' Plumbing Do Not cover Underground or Below/In-Slab Work Prior To Approval Of The Above Insnections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof',' 7 Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather a City of Wheat Ridge Residential Roofing PERMIT - 201702783 PERMIT NO: 201702783 ISSUED: 06/28/2017 JOB ADDRESS: 3605 Dudley ST EXPIRES: 06/28/2018 JOB DESCRIPTION: Residential reroof: Install 33 squares OC duration storm asphalt shingles house and garage 5/12 *** CONTACTS *** OWNER (303)422-9034 GONZALES DEBORAH MARSHALL SUB (303)552-4467 John Hess 150142 Urban Exteriors, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,260.00 FEES Total Valuation 0.00 Use Tax 152.46 Permit Fee 172.60 ** TOTAL ** 325.06 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€rms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. ® ' City of Wheat Ridge �J Residential Roofing PERMIT - 201702783 PERMIT NO: 201702783 ISSUED: 06/28/2017 JOB ADDRESS: 3605 Dudley ST EXPIRES: 06/28/2018 JOB DESCRIPTION: Residential reroof: Install 33 squares OC duration storm asphalt shingles. house and garage 5/12 *** CONTACTS *** OWNER (303)422-9034 GONZALES DEBORAH MARSHALL SUB (303)552-4467 John Hess 150142 Urban Exteriors, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,260.00 FEES Total Valuation 0.00 Use Tax 152.46 AID Permit Fee 172.60 ** TOTAL ** 325.06 -- — *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A1/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturerioms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge AF Adir Residential Roofing PERMIT - 201702783 PERMIT NO: 201702783 ISSUED: 06/28/2017 JOB ADDRESS: 3605 Dudley ST EXPIRES: 06/28/2018 JOB DESCRIPTION: Residential reroof: Install 33 squares OC duration storm asphalt shingles. house and garage 5/12 I, by n signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the len�al owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. [further attest that I am legally authorized to include all entities named within this document as parties to the work to be perfor�, ed and that all work be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNED or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subdect to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This, permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, anew permit maybe required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and hispection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subjetttq field inspection. i°— Signature of Chief Building Official Date REQUESTS MUST HE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgei.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Antoinette Kulick From: no-reply@ci.wheatridge.co.us Sent: Friday, June 16, 2017 1:18 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application �-- Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 3-5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION 1,50 f �— Property Address 3605 Dudley St. Property Owner Name Property Owner Phone Number Property Owner Email Address Deborah Gonzales 303-422-9034 Field not completed. Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Urban Exteriors LLC 150142 303-552-4467 Contractor Email Address jennifer@urbanexteriorsllc.com (permit pick-up instructions will be sent to this email) Retype Contractor Email Address DESCRIPTION OF WORK Are you re -decking the roof? Description of Roofing Material Select Type of Material If "Other" is selected above, describe here: How many squares of the material selected above? Does any portion of the property include a flat roof? If yes, how many squares on the flat roof? jennifer@urbanexteriorsllc.com No OC Duration Storm Asphalt Field not completed. 33 No Field not completed N TOTAL SQUARES of all 33 roofing material for this project Provide additional detail House and garage 5/12 here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 7,260 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Jennifer Hess Email not displaying correctly? View it in your browser. 3 -.1 - I - . �.-_ Urban Exteriors 2 Urban Exteriors, LLC 3440 Youngfield Street, Suite 179 Wheat Ridge, CO 80033 303.552.4467 www.urbanexteriorst(c.com MEL Insurance Company:r Address: `: r„ C� v COLORADO RVUFING ASSOCI A)i UN ��Name:, Insurance Company:r Address: `: r„ C� v Phone #: Cit ` y. �rr- - State: Zip: 2, Claim #: `� , Phone #: j Project Manager. �1 Mobile #: Phone #: Email I Date. -^ LO 1/WE, the Owner(s) of the premises described above authorize Urban Exteriors, llc, hereinafter referred to as "Contractor", to furnish all materials and labor necessary to roof and/or improve these premises in a good, workmanlike and substantial manner according to the to terms, specifications and provisions:' a.Description of the work and the materials to be used: r- _ yC at ✓ewe=� e .4 e, -`a; cam, � e 1 tN,NURANCE: 1HE UNLY COS't' l FOTHE PROPERTY OWNER IS THEIR DEDUCTIBLE PLUS ANY UPGRADES CHOSEN OR ANY NON COVERED ITEMS THAT MUST BE REPLACED TO COMPLETE THE REPAIRS. THE CONTRACT BALANCE IS PAID BY YOUR INSURANCE COMPANY PER FINAL LOSS INVOICE. THIS AGREEMENT IS NULL AND VOID AND DOES NOT OBLIGATE ANY PARTY TO IT SHOULD THE INSURANCE COMPANY REFUSE COVERAGE UNDER THIS CLAIM OR SHOULD THE COVERAGE OFFERED BE INSUFFICIENT FOR CONTRACTOR TO PROPERLY DO THE WORK. THE SCOPE OF WORK WILL BE DEFINED BY THE INSURANCE COMPANY LOSS SHEET AND ALL REVISIONS THEREOF. ANY ADDITIONAL WORK MUST BE SUBJECT TO A CHANGE ORDER AND/OR CONTRACT SIGNED BY THE PARTIES. b. Description of any areas that will NOT be worked on: ? �_;4(ct This list of specifications maybe co"ntinued on subsequentfages (seepage number below). e. Payment: Contractor proposes to perform the above work, (subjec to any additions and/or deductions pursuant to authorized change orders), for the 55!`7. (o`iz Total Sum oof $$ ¢ Down Payment $(tj?-n< a d. Commencement and Completion of Work: Substantial commencement of work shall ma either the physical delivery of materials onto the ._ premises or the performance of any laborall be u sect to any rmissible delays as per provision (5) on the reverse side. Shingle Mfg, Type & Color: :.+,� _--a, Asa abet abor Warranty: 5 yrs, transferrable - provided upon payment in full e. Acceptance: The contract is approved and accepted. I (we) understand there are no oral agreements or understandings between the parties of this agreement. The written terms, provisions, plans (if any) and specifications in this contract is the entire agreement between the parties. Changes in this agreement shall be done by written change order only and with the express approval of both parties. Changes may incur additional charges. Additional Provisions of This Contract Are On The Reverse Side And May Be Continued on Subsequent Pages. A copy of the labor warranty is available upon request. Urban Exteriors shall hold in trust any payment received from you until Company has delivered roofing materials at the site or has performed a majority of the roofing work on your property. You, the Buyer, may cancel this transaction at any time prior to midnight of the third business day after the date of this transaction. See attached Notice of Cancellation form an explanation of this right. MUST BE MAIDE P YABLE TO URBAN EXTERIORS, LLC. Ter's ignature date Aanager s Signature date hereby grant Urban Exteriors fi ission to speak with my insurance company for the purpose of resolving this claim. Urban Exteriors has permission to discuss my claim with my mortgage comnanv. if anolicable. i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ? �/ 7 bZ 7 X Z A i ❑ No one available for inspection: Time -(SM/PM Re -Inspection required: Yes NJ When corrections have been made, call for re -inspection at 303-234-5933 Date: It Z�0 //T Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 3 U8jJ/74 TT Permit Number: 7 V ❑ No one available for inspection: Time U 6IiIPM Re -Inspection required: YesI When corrections have been made, call for re -inspection at 303 -234 - Date: / / Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time I / _ / () XMIPM Re -Inspection required: Yes V When corrections have been made, call for re -inspection at 303 -234 - Date: _71L?117 Inspector: DO NOT REMOVE THIS NOTICE COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: Date: 7/17/2003 15880 Property Owner: LELAND MARSHALL Property Address: 3605 DUDLEY ST Contractor License No. : Company: Phone: 422-9034 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED V #1t-t~A DATE 7/;ro/~ ") Description: INSTALL GAS FIREPLACE IN SINGLE FAMILY RESIDENCE. Construction Value: Permit Fee: Plan Review Fee: Use Tax: Total: $4,000.00 $126.50 $0.00 $80.00 $206.50 Use: BUILDING DEPARTMENT USE ONLY Zoning.(:;omments;: Approval: Zoning: Buildih-g: Comm~~~t Approval: OM publiC1Works:flQ1htn~nts:. Approval: Occupancy: Walls: SIC: Sq. Ft. TO BE INSTALLED PER MANUFACTURES INSTALLATION INSTRUCTION, 7/17/03 Roof: Stories: Electrical License No : Company: Plumbing License No : Company: Expiration Date: Approval: Expiration Date: Approval: Residential Units: Mechanical License No : Company: Expiration Date: Approval: This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the Stale of Colorado and to the Zoning Regulations and Building Code of Wheal Ridge. Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediin ith successive phases of the job. Th is n c ~f a e . r the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provi . ns th codes or any other ordinance, law, rule or regulation. , ~ Chief Building "({pector Please sign Terms and Conditions on reverse side of page. (1) (2) (3) (4) (5) (6) (~, u~~ C'oLOR",CO COMMUNITY DEVELOPMENT DEPARTMENT BUILDING I!'\SPECTlON LI!'\E - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH A VENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPLICATION L.e ~a-vr:J. JVlGl~~)/ 3b6b P!)o/ley O:;-b. Building Pennit Number: Date: i \ / .'~~ ( ! t\ , ,fl';c; ~ Property Owner: Property Address: Contractor License No.: Company: Wheat- R..'>.h~ Q) ~~ Phone: ~.,14~-rt;l:fI- . i1Ir>rJ. ~ 7. II"?- (C Phone: V/~ ~~I'~?l~~ O\\':'\ERJCO!\'TRACTOR SIGZ'OATI'RE OF l'SDERSTA:'iDlXG A:'I.'O AGREEM[i'\T (OWNERXCO!\."TRACTOR): SrGI\ED )f~~~ om?/; ~}' Construction Value:$ 0.YJ/1-~" Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ I hereby certify that the setback distances proposed by this permit application arc accurate, and do not violate applicable ordinances, rules or regulations of the City o(Wheat Ridge or covenants, easements or restrictions of record; that all measurements 5hO'.\11 , and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume fuB responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit (O\V~ER)(CO~TRACTOR): PRJI'.'TED DATE DESCRIPTION: .h,fTI;<>t}J 9C6 --F;~)o.ce IV) BUILDING DEPARTMENT USE 01l:L Y SIC: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: 7zP k IF"J;lf.,JV~ tn'l<-IIAdv=-y; l~krl&J,'Cr" Approval: -W15frllqiu') 7//;/05 p.~ PUBLIC WORKS COMMENTS: i7 Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: ExplTation Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (I) TIlis pemlil was issued in accordance with the provisions set forth in your application and is subjecllO the laws oflhe Slale of Colorado and to the Zoning Regul:ltiolls and Building Codes of Wheat Ridge. Colorado or any other applicabk ordinances of the City (2) This pC'mlit shall ex-pire if(A) the work authorized is not commenced within six-t} (60) days frOnl issue date or (B) the btlilding atlthorized is stlspended or abandoned for a period of 120 days. (3) If this permit upires. a new pemlit may be acquired for a fee of one-half the amOtlnt 110mlally reqtlired. provided 110 changes hal'e been or will be made in the original plans and specifications and an)" suspension or abandonmem has 1101 ex-ceeded one (I) year. If changes have been or if suspension or abandonment e:l.ceeds one (I) year, full fees shall be paid for a ne..... p~rmil. (~) 1'0 .....ork of any mann~r shall be done that will change th~ nalunl flow of water causing a dninage problem. {5) Contractor shall notify the Btlilding Inspector t\1.'~nty-four (24) hours in advance for all inspections and shall receive wriuen approval on inspection card before pnxeeding with successiv~ phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed 10 be a pemtit for. nor an approval of. any violation of tlle p'"',;o,,, ~mg 'od"~',"Y oU,,, o,di,,,,,,,. ,,". '"', 0' "g"''''OO ChiefBuildin Lee !l1qB;h<?'1 ~b vlxlJt'y <;;-b~ ;fh--!:ufC:/1 Gts hYe I !q<e A~)(qb~r; IT ~ Ver-bid7i/ Ven-c 7i?J<M}~~ .;;Z.:)<_ J1l/ ! b I j \) DC, CP1/e..~ CPf)~ h~ (q)1. ~ e,5) // /~ /~.-/ /~~ //.. ""rtle,t:?pP(' < (~G:?(' \ 'Sv~e/ . I/Jew t.:h ;');- , "/=;<f'et ~e t!::--'L-- c:; , ---;, /r-~m '5 ,< /' J1} Jt, J/ O.e, " I 6 Features and 5 ecifications Features: Works During Power Outages (millivolt system) High Efficiency Optional Thermostat or Remote Control Realistic "Wood Fire" Look Quiet Blower for Effective Heat Distribution Convenient Operating Controls Variable-Rate Heat Output Low Maintenance Heating Specifications: Natural Gas Propane Approximate Heating Capacity (in square feet)* 1,200 - 2,250 1200 - 2,250 Maximum BTU Input Per Hour 43,000 43,000 Minimum BTU Output on Low (with blowers on) 23,384 20,800 Efficiency" (with blowers on) Up to 79% Up to 80% AFUE (Annual Fuel Utilization Efficiency) 72% 73% . Heating capacity will vary with floor plan, insulation, use of Power Heat Duct, and outside temperature. .. Efficiency rating is a product thermal efficiency rating determined under continuous operation independent of installed system. Installation ODtions: Residential or Mobile Home Straight or Corner Placement Flush or Recessed Face Raised or Floor Hearth Internal or External Chase Horizontal or Vertical Vent Power Heat Duct 1/2- Stand-ofts Weight: 250 Lbo. The electrical connection is made in the lower right rear corner. Dimensions: y I 40. 23. 26-3/4. Nail Down Plate (used to secure the fireplace to the floor) * Includes the 1/2" stand-offs Travis Industries 4030228 93508128 '\ ~ 8 Installation (for qualified installers only) Fireplace Placement Requirements Minimum Framing Dimensions The 1/2" stand-offs on the back and sides and 6-1/4" stand-oils on the top of the fireplace are designed to separate the fireplace from the framing members. These stand-oils may contact the framing members but no material may be placed between the stand-oils. ............. ....~ , I ......... NOTE: if venting directly to the rear. make sure there is a min. 8-5/8" space centered behind the fireplace for the wall thimble. If a 90" elbow is used directly off of the fireplace, the thimble will be centered 51-1/4" above the base of the fireplace. 1 46-1/2" If using a remote control or thermostat, route the wire to a location near the gas line (include an extra 3' length for hookup). UJ ~ /,,[j 19-5/8" /~ 43-1/4" ~ III Gas line (318" M.P.T. or 1/2" F.P.T.) should be routed 6-5/8" behind the framing opening and 1-7/8" above the base of the fireplace (see "Gas Une Connection" for details). Route the electrical line to a position at the right rear of the fireplace. ~ NOTE: If using the power heat vent, allow for the duct passage when framing the enclosure. . Fireplace must be installed on a level surface capable of supporting the fireplace and vent . Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet) . Due to the high temperature of the fireplace, it should be located out of trallic and away from furniture and draperies. . This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces when determining a location. Clearances . When installed, walls in front of the fireplace must be a minimum 4-1/2" to the side of the faceplate. . Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of the fireplace (e.g. drapes, doors) . Fireplace must be placed so the vents below and above the glass do not become blocked Travis Industries 4030228 93508128 '" ., Hearth Requirements Floor Mounted Fireplaces Min. 3/4" Max. 15/16~ Do not build the hearth above this ledge. Tite. Marble, Brick, or other / Non-Combustible Raised Fireplaces When raised a minimum 01 3" off of the floor surface, no hearth is required. Fireplace Stand Make sure to accomodate the floor covering (carpel, linoleum, flooring, elc.) when determining the height of the lireplace stand (i.e. the thicker the carpel. the taller the fireplace stand). Travis Industries 4030228 93508128 I ~i Installation (for qualified installers only) 11 Facing Requirements NOTE: The combustible area above the tacing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual. NOTE: The facing may be attached to the front of the fireplace with screws. Do not penetrate the fireplace more than 3/4". 1 10"Min. I The fireplace requires a concrete board (or Lj-PV other non-combustible) extending from the header to the floor and to the framing ;iX@Vi"YV;;VX!W!WH; . R-=~=:::-~="'" Header 30. Arch face 28-1/2" Rectangular face 30-3/8" Architeclural face _ 4.112" Min. (both sides) Base of Fireplace " Facing Over 1" Thick . For rectangular faces. use a piece of plywood cut to the dimensions shown on page 13 (add 1/8" to each dimension). . Artisan faces vary in size. Use the face being installed to create a template. I I Center Line J~l~tf~Ji~~eW~i%~~b~~~~ requirements . Architectural faces require a 5/8" gap above the face for face installation. . If the facing material is over 1 " thick (e.g. brick, river rock). install the facing around the perimeter of the face. You may wish to make a face template (see the illustration to the right). If using an arch face. you may wish to order the optional set-up face: Arch Set-Up Face Part # 98500692 Face Templale '<sl 't% / 1 u,. ~~~e~~d'~~ftg~ !~~a~.~~irEif'6~~112~ r~ 6~g:~~s~~~sa~f[g~P$tJii~tJ~~~~~_lwen the /' '~i \~~ti. 'O~i i. ~ "' , .... -'" ote: The brict lucks <t ....~ ~',"'''''~'''''''''' 01"'" The face template shoold be liS" larger lhan the I~S~ ,:~w~hsme~~~~~~~l~~ ~di~geth~;ng ~~u~YF1~~~~I~u~,rah~<tf::~lenaland Travis Industries 4030228 93508128 Facin Detail NOTE: The overlap is '-1120 along lhelopollhetace. '-318" Rectangu!ar Faces 1/4" Arch Faces JJ8"Architectural Faces (\ Do not tuek tile unQemflllth the face on the bottom (there will be a 112" air space ~ the access door). You may do this on the sides and lop, but not on the bottom. 13.~4' 23' 26-3140 Y' . To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing directly next to the fireplace. See the illustration below. TOP VIEW ~ 3/8" Tile 1/2" Concrete Board I ,. 1 I Faceplate 1/2" Drywall I " 1 I Faceplate The tile overlaps the drywall for an overlap lacing 1 3/8" Tile 1/2" Concrete Board Travis Industries 4030228 93508128 Vent Installation . In addition to the requirements below, follow the requirements provided with the vent. Vertical Termination Vertical Vent Requirements Use a roof flashing and storm collar whenever passing through the roof Use a firestop whenever passing through a ceiling Minimum framing for fire stop Use a support box on exposed vent -+ Maintain a minimum 1" clearance from vent to any combustible Horizontal Vent Requirements Minimum Framing for wall thimble ~ Maintain a minimum 1 M clearance (2" in -----::; '\ some cases - see "Clearances") from vent to any combustible . Slide the vent sections together and turn 1/4 turn until the sections lock in place. . Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired. . High temperature sealant is recommended at the appliance starter section connection (use high-temperature silicone or Mill-Pac@). . If disassembly is required, at time of re-assembly check to see if the vent creates a tight fit. If it does not, apply high temperature sealant to the joints of the affected sections. . Horizontal sections require a 1/4" rise every 12" of travel . Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape) Travis Industries 4030228 93508128 Il/ ~. / Installation (for qualified installers only) 19 Approved Vent Configurations Restrictor Position . A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures proper combustion for all vent configurations. Depending upon the vent configuration, you may be required to adjust the restrictor position. The charts for acceptable vent configurations detail the correct vent restrictor position. ----- Adjustment \ Plate Adjustment Bracket This restrictor is in position 1 (factory setting). Elbows . A maximum of three 900 elbows or four 450 offsets may be used. See the vent configurations for details. NOTE: one 450 elbow may be used between two horizontal sections. Measuring Vent Lengths To Access the Restrictor: With the face removed and the fireplace cool, reach above the firebox. To Adjust the Restrictor: WARNING: Use a glove to protect your hand from burns. 1 Determine the correct restrictor position (see the charts under "Approved Vent Configurations" - the factory position is #1). 2 Lift up the adjustment plate and move it so the correct notch falls into the slot on the adjustment bracket. ~tC.#2 #7 #8 . it ~ This restrictor is in position 7. To adjust, lift up on the adjustment plate and push it back. Elbows add 3' to the length of Ihe venl system. fd1 1-3' Side View 12.310'tal~1 ~ with 1-1/2' ~ oloverlap y 19-5/0' ~11.518" T 1-1/2' / 8-3/4' (10_314U) wide with 1.1/2' to 3-318' of overlap Vent sections overlap each other by 1-1/2' 1\\ 1/1 ~ Tot. Vent Length 14..3..'''.1 46--1/4" EXAMPLE: Two 4' lengths are 7' 10-t/2' long, but when attached to the vent system add 7' 9" to the vent height. Adds 8' 10 System Heignl . NOTE: (Total = 9-114' Tall) All measurements are lor 6-5/8' diameter vent except IOf those marked with an aslerik (0), which are for S", Travis Industries 4030228 93508128 Termination Requirements (see the illustration below) A Minimum 9" clearance from any door or window B Minimum 12" above any grade, veranda, porch, deck or balcony C Minimum 12" from outside corner walls D E "..Min.j 16" Min. EjJp Roof Eaves Minimum 12" from inside corner walls Minimum 11" clearance below unventilated soffits or roof surfaces Minimum 18" clearance below ventilated soffits Minimum 6" clearance from roof eaves NOTE: Vinyl surfaces require 24" F Minimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides) G Minimum 48" clearance from any adjacent building H Minimum 84" clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building I Minimum 48" clearance from any mechanical air supply inlet, 72" for Canada J Minimum 36" clearance above and 48" below and to the sides of non-mechanical air supply inlet K Minimum 36" from the area above the meter/regulator (vent outlet) L Minimum 36" from the meter/regulator (vent outlet) M Minimum 12" above the roof line (for vertical terminations) 'Note: In Canada the vent termination must be a minimum 2' (.6 M) tall and 2' (.6 M) above any portion 01 the rool within 10' (3 M) 01 the vent. Minimum 24" horizontal clearance to any surface (such as an exterior wall) - for vertical terminations N -LM I E E <lID ~ /'IJ 10 H . NOTE: Measure cfearances to the nearest edge of the exhaust hood. . Use the vinyl siding standoff (#950) when installing on an exterior with vinyl siding. . Vent termination must not be located where it will become plugged by snow or other material . These clearances meet UMC-1994 and the CNA/CGA-B149 code standards. Travis Industries 4030228 93508128