i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office_ IWSPECTION NOTICE' Inspection Type: Job Address: _ 24 Permit Number: `j ❑ No one available for inspection: Ti M/ M Re -Inspection required: Ye . No When corrections have been made, schedule for re -inspection online at: h ttp://www. ci. wheatridge. co. usA1nspec _666� Dat6: 1�> •_202 Inspect© DO NOT REAJO`VE THIS NOTICE SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 9765W DC, 760OW AC • ALL WORK SHALL COMPLY WITH IBC 2012, MUNICIPAL CODE. AND ALL SOLAR MODULES PV-1 0 COVER SHEET • MODULES: (31) LONGI GREEN ENERGY TECHNOLOGY CO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. rSE) SERVICE ENTRANCE LTD: LR6-60HPH-315M • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-2.0 SITE PLAN PV-3.0 LAYOUT • INVERTER(S): • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. (1) SOLAREDGE TECHNOLOGIES: SE760OH-US WITH • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY MP MAIN PANEL REVENUE GRADE METERING GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. PV-4.0 ELECTRICAL PV-5.0 SIGNAGE • RACKING: SNAPNRACK RLU; RL UNIVERSAL, MOUNT KIT, • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SNR MOUNT SEE DETAIL SNR-DC-00369 • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SUB-PANEL SNR MOUNT & SKIRT R • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE II MODULES, ARE CLASS A FIRE RATED. LC PV LOAD CENTER CHIMNEY • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ATTIC VENT • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). SM SUNRUN METER • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. *0 • 9.94 AMPS MODULE SHORT CIRCUIT CURRENT. FLUSH ATTIC VENT • 15.53 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. PM DEDICATED PV METER PVC PIPE VENT IN • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B) o (2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION INVERTER(S) WITH ® METAL PIPE VENT INV INTEGRATED DC N DISCONNECT AND AFCI T-VENT O AC AC DISCONNECT(S) D SATELLITE DISH 1. DC DISCONNECT(S) FIRE SETBACKS L C A F7A Q CB HARDSCAPE O COMBINER BOX F_ —1 INTERIOR EQUIPMENT — PL— PROPERTY LINE LF :11 SHOWN AS DASHED SCALE: NTS sunrun A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION EC#7080, ME#30603 DC DIRECT CURRENT (E) EXISTING 6040 WEST 91ST AVENUE, WESTMINSTER, CO $0031 EXT EXTERIOR PHONE 303.577.6527 FRM FRAMING FAX 303.577.9629 CUSTOMER RESIDENCE: v .►+, INT INTERIOR FaSI auW WA; or Wheat vv h�t�� LBW LOAD BEARING WALL DONNA HALLEWELL JELLISON ST, WHEAT wsSinAa� =� CoMMulvmpEw MAG MAGNETIC 3244 �orMtr►r MSP MAIN SERVICE PANEL RIDGE, CO, 80033 APPROVED (N) NEW w3atn Ave n - Reviewed for Code, NTS NOT TO SCALE TEL. (303) 234-1190 \I W3a �� `� OC ON CENTER APN #: 94008 iFOP€$APTISY 'z cwuFSLw "' PRE-FAB PRE-FABRICATED PROJECT NUMBER: „ PSF POUNDS PER SQUARE FOOT 501 R-244HALL 3244 Jetson StEcrt PV PHOTOVOLTAIC 415 580-6920 ex3 DESIGNER: ( ) TL TRANSFORMERLESS oat• TYP TYPICAL AMIT MAHAJAN x Yi�hrntoaMk The penrrerm•«.Iow,,.,,,aloas V VOLTS SHEET o y •nd canpurofions shah not be a permit apprwp/� �,O tee- nnya, the wcrs;arharhtDull�nOcode«n,.�r� W WATTS REV NAME DATE COMMENTS % e, p«run'NtOgive outhor`n'R°�enlcm+c thz - codes �F COVER SHEET or crhe, crdtnances o the otYsharOtbevalid, . REV: B 1/8/2020 i PAGE PV-1.0 I3 ARRAY TRUE MAG PV AREA SITE PLAN - SCALE = 1/16" = 1'-0" PITCH AZIM AZIM (SQFT) ® AR -01 18° 287° 98° 559.3 P� aJ P( Pk P( FIRE SETBACKS - - (3, TYP) aJ a (N) ARRAY AR -01 - a (E) GATEMP aJ a INV � PM � SE a a sunrun EC #7080, ME #30603 _ 8040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 PHONE 303.577.8527 B _ FAX 303.577.9829 a °, -- - (E) RESIDENCE CUSTOMER RESIDENCE: DONNA HALLEWELL ' < 3244 JELLISON ST, WHEAT RIDGE, CO, 80033 n ° TEL. (303) 234-1190 ° ° n APN #: 94008 P °•' 4 ° e. city of PROJECT NUMBER: k 501 R-244HALL W eat Ridge (415) 580-6920 ex3 Pt DESIGNER: °.y 4' �.. •° ° s a•. 9 Division ✓ AMIT MAHAJAN FSC/gpNs T - (c) z�-zs) SHEET (E) DRIVEWAY SITE PLAN REV: B 1/8/2020 PAGE PV -2.0 ROOF ROOF FRAME MAX FRAME OC ROOF EDGE MAX PEN MAX MoD. DESIGN CRITERIA ROOF TYPE MOUNTING DETAIL HEIGHT EXPOSURE MATERIAL FRAME TYPE SPAN SPACING ZONE SPACING OVERHANG MODULES: AR -01 COMP SHINGLE - RLU RL UNIVERSAL, MOUNT KIT, SEE DETAIL 1 STORY EXPOSED WOOD 4X12 RAFTERS 18'- 5" 48" 3' 4'- 0" 2'- 0" LONGI GREEN ENERGY TECHNOLOGY CO LTD: SNR -DC -00369 LR6-60H P H-315 M D1 - AR -01 - SCALE: 3/16" = 1'-0" MODULE DIMS: PITCH: 18° 66.26" x 39.21"x 1.38" (36m m) AZIM: 287° MODULE CLAMPS: Portrait: 14.6" - 18.5" Landscape: 5.9" - 9.8" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30 PSF WIND SPEED: 105 MPH 3 -SEC GUST. 55'-6" —3— S.S. LAG SCREWS: 5/16"x5.0": 2.5" MIN EMBEDMENT N NOTE: INSTALLERS TO VERIFY RAFTER I 3' SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF BEFORE ANY DISCREPANCIES PROCEEDING. —47YP— PENETRATION SPACING: FULLY STAGGERED ROW SPACING: 0.75" BETWEEN ROWS COLUMN SPACING: 13'-3" 0.75" BETWEEN COLUMNS In sunrun T-10" EC #7080, ME #30603 8040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 q 22'-2" 11'-2" .1 5'-7" 16'-7" - 3' - PHONE 303.577.0527 FAX 303.577.9829 CUSTOMER RESIDENCE: DONNA HALLEWELL 3244 JELLISON ST, WHEAT RIDGE, CO, 80033 TEL. (303) 234-1190 APN #: 94008 City or PROJECT NUMBER: 501 R-244HALL DESIGNER: (415) 580-6920 ex3 (*:dg�e rar? AMIT MAHAJAN SHEET C ' CQ Z��Q LAYOUT REV: B 1/8/2020 PAGE PV -3.0 SEE SITE PLAN FOR NORTH ARROW 120/240 VAC SINGLE PHASE SERVICE O UTILITY GRID METER #: XCEL D1203564 SUPPLY SIDE TAP C 1 EXISTING 150A (N) LOCKABLE [VISIBLE OPEN] SOLAREDGE TECHNOLOGIES: MAIN BREAKER BLADE TYPE (N) LOCKABLE SE760OH-US WITH REVENUE FUSED AC (N) DEDICATED BLADE TYPE GRADE METERING 1 DISCONNECT PV KWH METER AC DISCONNECT 7600 WATT INVERTER JUNCTION BOX n n n OR EQUIVALENT EXISTING 200A MAIN FACILITY PANEL LOADS I FACIJTV 04�0 140A FUSES SQUARE D 240V METER SOCKET SQUARE D D222NRB 200A CONTINUOUS DU222RB 3R, 60A WITH LEVER BYPASS 3R, 60A,2P 120/240VAC [MAX 10' FROM 120/240VAC (4) 10 AWG PV WIRE UTILITY METER] [MAX 10' FROM UTILITY METER] (1) 6 AWG BARE COPPER [READILY ACCESSIBLE MEANS 3/4" EMT OR EQUIV. FOR RAPID SHUT DOWN] LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN COMPLIANT CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPH-315M: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT P320 OPTIMIZER CHARACTERISTICS: SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: MIN INPUT VOLTAGE: 8 VDC 16 V MAX INPUT VOLTAGE: 48 VDC 315 W MAX INPUT ISC: 11 ADC 40.6 V MAX OUTPUT CURRENT: 15 ADC 33.7 V 9.94 A SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: 9765 W SYSTEM OPEN CIRCUIT VOLTAGE: 16 V SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 24.41 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PV MODULES LONGI GREEN ENERGY TECHNOLOGY / CO LTD: LR6-60HPH-315M (31) MODULES OPTIMIZERS WIRED IN: (1) SERIES OF (15) OPTIMIZERS (1) SERIES OF (16) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS P320 NOTES TO INSTALLER: • 16 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. • CONNECT SYSTEM VIA METER LUG ADAPTER ON SUPPLY SIDE CONDUCTORS IN UTILITY METER ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. • FIELD SPLICE WIRE TO APPROPRIATE SIZE FOR MANUFACTURE TERMINATION SPECIFICATIONS WHEN NEEDED. WIRE UPSIZE AT TIME OF INSTALLATION IS PERMISSIBLE. Cit' of Whaat Rld9e $uildin9 Divlsio� &WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2017:690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) /!WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM IAWARNING ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): NEC 2017:690.5(C), NEC 2014: 690.5(C), NEC 2011: 690.5(C) WARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS I INVERTER 1 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2017:690.53, NEC 2014:690.53, NEC 2011: 690.53 LABEL LOCATION: LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF UTILITY SERVICE ENTRANCE/METER, LABEL LOCATION: INVERTER/DC DISCONNECT IF REQUIRED BY UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b), LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: BY LOCAL AHJ. PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b), 705.12(D)(4) PER CODE(S): NEC 2017: 690.12, NEC 2014: 690.12, NEC 2014: 705.12(D)(3), NEC 2011: NEC 690.56, IFC 2012: 605.11.1 705.12(D)(4) &WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017: 690.31(G)(3), 690.31 (13)(4), NEC 2014: 690.31(G)(3), 690.31 (13)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 3.5" SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF LABEL LOCATION: INTERCONNECTION. ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE PER CODE(S): NEC 2017: 690.54, NEC 2014: 690.54, NEC DISCONNECTING MEANS TO WHICH THE PV SYSTEMS 2011: 690.54 ARE CONNECTED. PER CODE(S): NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION. POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR PANELS ON ROOF SERVICE ENTRANCE AND PV BREAKER DISCONNECT AC DISCONNECT PV PRODUCTION METER e INVERTER (EXT) AC DISC NECT W ear Rldop B 9 Divisicn 3244 JELLISON ST, WHEAT RIDGE, CO, 80033 sunrun EC #7080, ME #30603 6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 PHONE 303.577.6527 FAX 303.577.9629 CUSTOMER RESIDENCE: DONNA HALLEWELL 3244 JELLISON ST, WHEAT RIDGE, CO, 80033 TEL. (303) 234-1190 APN #: 94008 PROJECT NUMBER: 501 R-244HALL DESIGNER: (415) 580-6920 ex3 AMIT MAHAJAN SHEET SIGNAGE REV: B 1/8/2020 PAGE PV -5.0 , City of Wheat Ridge Residential Solar PERMIT _ 201902310 PERMIT NO: 201902310 ISSUED: 11/04/2019 JOB ADDRESS: 3244 Jellison St EXPIRES: 11/03/2020 JOB DESCRIPTION: Solar PV install, 9.765 kw, 31 panels, no structural required. **REVISION: 3 modules relocated. No added valuation. *** CONTACTS *** OWNER (303)234-1190 HALLEWELL DONNA SUB (303)577-9628 ANDY NYMAN 070159 SUNRUN INSTALLATION SRVS. INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,260.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perfpor d th ork to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER oc��R (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit tee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services 6. The issuance or grar4igg of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any ap le code or 41yordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. A X Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. W City of VAI heat P,idge C OMMUNrry DwELC rmr-N?- Building & Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(aDd.wheatridge.co.us FOR OFFICE USE ONLY Date: X1/0 Add to Permit # fir/ �r_1 Building Permit Revision/Amendment Application I Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ' Property Address: 3244 Jellison St Wheat Ridge CO 80033 Property Owner (please print): Donna Hallewell Phone: 303-234-1190 Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: Submitting Company: Sunrun Installation Services Inc Contact Person: Thomas M. Brook Phone: 720-537-0235 Contractor: Sunrun Installtion Services Inc Contractors City License #: 070159 Phone: 303-577-9628 Contractor E-mail Address: colorado.permitting@sunrunhome.com Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: Sq. FULF Amps 3 modules relocated, see PV -2.0 and -3.0 Btu's Squares Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) $ n/a OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: Thomas M. Brook ZONING COMMMENTS: Reviewer. BUXPING DEPARTMENT COMMENTS: R ewer: PUBLIC WORKS COMMENTS: Reviewer: SIGNATURE: ' '"''� r' DATE: 01/09/2019 PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of Wheat Ridge Residential Solar PERMIT - 201902310 PERMIT NO: 201902310 ISSUED: 11/04/2019 JOB ADDRESS: 3244 Jellison St EXPIRES: 11/03/2020 JOB DESCRIPTION: Solar PV install, 9.765 kw, 31 panels, no structural required *** CONTACTS *** OWNER (303)234-1190 HALLEWELL DONNA SUB (303)577-9628 ANDY NYMAN 070159 SUNRUN INSTALLATION SRVS. INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,260.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by m signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I furt7al test that m legally authorized to include all entities named within this document as parties to the work to be performed an awort performed is disclosed in this document and/or it 'accompanying approved plans and specifications. 9���� � f7o- ? I, � c, Signature o6WNER or IfZAC ircle one) Date I . This permit was issued b d on the infor tion provided in the permit application and accompanying plans and specifications and is subject to the compliance witfil -5'e ocuments, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subjectto the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4• No work of any manner shall be performed that shall results in a change. of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or Oeplation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heatiidgc OMMUNriy DLV1-.L0I'MINT Building & Inspection Services 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permits(a-_)ci.wheatridqe.co.us FOR OFFICE USE ONLY Date:1 0 �1' l Plan/Permit#aU t ////"''ilii (� V Plan Review Fee: ' 0 V Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3244 Jellison St Wheat Ridge CO 80033 Property Owner (please print): Donna Hallewell Phone: 303-234-1190 Property Owner Email: Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect(E ng;Lneer• Architect/Engineer E-mail: Contractor Name: Sunrun Installation Services City of Wheat Ridge License #: 070159 Phone: Phone: 303-577-9628 Contractor E-mail Address: colorado.permitting@sunrunhome.com For Plan Review Questions & Comments (please print): CONTACT NAME (please print): Thomas M. Brook Phone: 720-537-0235 CONTACT EMAIL(p/ease print): thomas.brook@sunrun.com Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. ❑COMMERCIAL ® RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Roof -mount, flush mount, grid -tied 9.765 kW Solar PV Sq. FULF BTUs Gallons Amps Squares For Solar: 9.765 KW 31 # of Panels no Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ 18260 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): �� W. 4�&B% DaTE: 10/31/2019 Printed Name: Thomas M. Brook ZONING COMMMENTS: Reviewer: BUILDIN DEPAR=MERT�OMM Revi er: PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: LR6-60HPH 300~320M Design (mm) Mechanical Parameters Operating Parameters Wim -000 Cell Orientation: 120 (6x20) Operational Temperature: -40G - +85 �C Junction Box: IP67, three diodes Power Output Tolerance: 0 - +5 W ,Zht ±1- Output Cable: 4nim', 300mrn in length Voc and Isc Tolerance: ±3% 780pcs per XHC Glass: Sirgle glass Maximum System Voltage; DC1500V (IEC/ UQ 3.2inm coated tempered glass Maximum Series Fuse Rating: 20A LR6-60HPH-300M Frame: ArkAzed aklMinUm al"me Test uncertainty LR6-60HPH-315M for Pmax: ±3% LRC,-60HPH-320M Testing Condition Nominal Operating Cell Temperature: 45±21C STC NOCT STC Weight: 18.9kg STC NOCT STC Dimension: 1683x996x35mm Safety Cass: Cass 11 300 222,2 305 225.9 310 Fire Rating: UL type 4 315 233.4 Packaging 30p:5 per pallet 237.1 Temperature Ratings ( STC ) Mechanical Loading Temperature Coefficient of Isc +0.057%/ , C Front Side Maximum Static Loading 540OPa Temperature Coefficient of Voc -0,28691.11c Rear Side Maximum Static Loading 2400Pa Temperature Coefficient of Pmax -0.37096/1C Hailstone Test 25mm Hailstone at the speed of 23m/s IL Current -Voltage Curve (LR6-60HPH-310M) Power -Voltage Curve (LR6-60HPH-310M) Current -Voltage Curve (LR6-60HPH-310M) 10 "' - Cell temp. -25C 12 Cell temp: u°C 300 _ 8 -,xi& ilnd��W 10 W- Ind-)WIn? 250 M,W Nd-Wlrn' -NntlMW/ 6 C-0 T -0-25T C.H 2DO 6 150 0 �N Tr,�C 400 01 2 CW T,,,,� 75,C 50 2 IW2W/m 0 0 01 OCS90 0 10 20 30 40 0 10 )n in n in In anL\ V.hge M n LONGI Solar vonage M Vollage M Room 201, Building 8, Sandhi]] Plaza, Lane 2290, Zuchongzhi Road, Pudong District, Shanghai,' r203 Tel:+86-21-61047332 Fax:+86-21-61047377 E-mail: module@longi-silicon.corn Facebook: www.facebook.corri/LONGi Solar Note; Due to continuous technical innovation, R&D and irTIP'oVefflerit, technical data above mentioned may be of modification accordingly. LONG Solar have the sole right to Make such modification at anytime without further notice; Demanding party shall request for the latest caLasheet for such as contract need, and make it a consisting and binding part of lawful docurnentation duly signed by both parties. V09 180pcs per 20`GP Efectrical Characteristics 780pcs per XHC Model Number LR6-60HPH-300M LR6-60HPH-305M LR6-60HPH-310M Test uncertainty LR6-60HPH-315M for Pmax: ±3% LRC,-60HPH-320M Testing Condition STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax/W) 300 222,2 305 225.9 310 229:6 315 233.4 320 237.1 Open Circuit Voltage (Voc/V) 39.8 37.1 40.1 37.4 403 37.7 40.6 37.9 40.9 38,2 Short Circuit Current (Isc/A) 9.70 7.82 938 7.88 9.86 7.94 9.94 8.01- 1002 8.08 Voltage at Maximum Power (Vmp/V) 319 30.4 331 30.6 33.3 30,8 317 31.1 33.9 1 313 Current at Maximum Power (Imp/A) 913 7.32 9.21 738 9.30 7.46 9,36 750 9.43 736 Module Efficiency(%) 17.9 18.2 18.5 18.8 191 STC (Standard Testing Conditions): Irradiance 1000W/rin2, Cell Temperature 25 C, Spectra at AM1.5 NOCT (Nominal Operating Cell Temperature): Irradiance 800W/m2, Ambient Temperature 20 C, Spectra at AM1.5, Wind at 1m/S Temperature Ratings ( STC ) Mechanical Loading Temperature Coefficient of Isc +0.057%/ , C Front Side Maximum Static Loading 540OPa Temperature Coefficient of Voc -0,28691.11c Rear Side Maximum Static Loading 2400Pa Temperature Coefficient of Pmax -0.37096/1C Hailstone Test 25mm Hailstone at the speed of 23m/s IL Current -Voltage Curve (LR6-60HPH-310M) Power -Voltage Curve (LR6-60HPH-310M) Current -Voltage Curve (LR6-60HPH-310M) 10 "' - Cell temp. -25C 12 Cell temp: u°C 300 _ 8 -,xi& ilnd��W 10 W- Ind-)WIn? 250 M,W Nd-Wlrn' -NntlMW/ 6 C-0 T -0-25T C.H 2DO 6 150 0 �N Tr,�C 400 01 2 CW T,,,,� 75,C 50 2 IW2W/m 0 0 01 OCS90 0 10 20 30 40 0 10 )n in n in In anL\ V.hge M n LONGI Solar vonage M Vollage M Room 201, Building 8, Sandhi]] Plaza, Lane 2290, Zuchongzhi Road, Pudong District, Shanghai,' r203 Tel:+86-21-61047332 Fax:+86-21-61047377 E-mail: module@longi-silicon.corn Facebook: www.facebook.corri/LONGi Solar Note; Due to continuous technical innovation, R&D and irTIP'oVefflerit, technical data above mentioned may be of modification accordingly. LONG Solar have the sole right to Make such modification at anytime without further notice; Demanding party shall request for the latest caLasheet for such as contract need, and make it a consisting and binding part of lawful docurnentation duly signed by both parties. V09 Complete System and Product Certifications Positive power tolerance (0 — +5W) guaranteed IEC 61215, IEC61730, UL1703 ISO 9001:2008: ISO Quality Management System ISO AWL 2004: 150 Environment Management System T562941: Guideline for module design qualification and type approval OHSAS 18001: 2007 occupational Health and Safety High module conversion efficiency (up to 19.1 %) Slower power degradation enabled by Low LID Mono PERC technology: first year <2%, 0.55% year 2-25 Solid PID resistance ensured by solar cell process optimization and careful module BOM selection Reduced resistive loss with lower operating current sp#(; �tons sub ect to techn.cat changes and tests. LONG. s Higher energy yield with lower operating temperature reservA� Qkight of interpretation. Reduced hot spot risk with optimized electrical design and lower operating current n do d aaAA++ ® Room 201, Building 8, Sandhill Plaza, Lane 2290, Zuchongzhi Road, Pudong District, Shang4 a1,201203 LONGI Sour Tel:+86-21-61047332 Fax:+86-21-61047377 E-mail:modu!e@longi-silicon.com_*\'4 r ;q Facebook: www,facebook.com/LONGI Solar * Note: Due to continuous technical innovation, R&D and irnp-ovement, technical data above mentioned may be of modification accordingly. LONG" Solar have right ake such modification at anytime without further notice; Demanding party shall request for the latest catasheet for such as contract need, and make it a consistin a. Ing part of lawful documentation duly signed by both partes. V 09 Single Phase Inverter WitHD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER OUTPUT SEXXXXH-XXXXXBXX4 Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 17650 W 3300 @ 208V 5100 5000 @ 208V 7750 - 10000 @ 208V W Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 1 7600 10000 11400 @ 240V VA 380 400 3300 @ 208V Maximum Input Current @240V@ 8.5 5000 @ 208V 13.5 16.5 20 27 30.5 10000 @ 208V Maximum Input Current @208Vr4 - AC Output Voltage Min. -Nom. -Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) Ground -Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 AC Output Voltage Min. -Nom. -Max % ✓ 99 ✓ % Nighttime Power Consumption < 2.5 083 - 208 - 229) - ✓ Vac AC Frequency (Nominal) 59.3 - 60 - 60.50) Hz Maximi �znuous Output 1240V.5 16 21 25 32 42 47.5 A CurrenMaximum �Continuous Output 16 - 24 - 48.5 A CurrenPower Factor 1, adjustable -0.85 to 0.8S GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 - 15500 W Transformer4ess, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V@ 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208Vr4 - 9- 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 t W n For other regional settings please contact SolarEdge support m A higher current source may be used, the inverter will limit its input current to the values stated Single Phase Inverter Wit HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US SE300OH-US811 111 .111 .0O000O0O ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional") Inverter Commissioning with the SetApp mobile application using built-in Wi-F station for local connection Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety 1-11-1741, UL1741 SA, UL16998, CSA C22.2, Canadian AFCI according to TIL M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4" minimum / 14-6 AWG 3/4' minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4' minimum / 1-2 strings / 14-6 AWG 3/4' minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in/ mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17.6 Ib / kg Noise < 25 <50 dBA Cooling Natural Convecton Operating Temperature Range -40 to +140 / -40 to +60K I Protection Rating NEMA 4X (Inverter with Safety Switch) rel Revenue grade inverter P/N: SE)umH-US000BNC4 R Full power up to at least 50'C / 1227; for power de -rating information refer to: httpsl/www.solaredge.com/sites/defautVfdes/se-temperature-deratirvg-note-na.pdf d WC`ea\�`d9A 8 dd� gO`vs� 12 SolarEdge Technologies, Inc. AN fights reserved SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Todmologlea, Int. All pu .,her trademarks mentioned herein are trademarlu of their respeeti" owners Data: 1/2019/V01/ENG NAM, Sub)ect to change without notice. R 4W solar SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P370 / P400 / P405 P300 P320 P370 P400 P405 (for 60 -cell mod- (for hi 8 p h- ower (for hipower (for 72 8c 96 cell (tor thin film �. 7 2 -cell I 660 and 72 -cell ules) 50 -sell modules) modules) modules) modules) ., . i ) € INPUT Rated Input DC Power ) 300 - 320 370 400 405 W Absolute Maximum Input Voltage Voc at lowest tem orotate 48 60 80 125 Vdc MPPT Operating Range $ - 48 80 12.5-105 Vdc Maximum Short Circuit Current (Isc) 10 11 10.1 Ado Maximum DC Input Current 12.5 13,75 12.63 Adc Maximum Efficiency.<.............................<......,,...<,...,...<.,...<...,.<....,...,,,.. 915 ...,,..,..,,.,..,.., Y 98.$...,,..< % Overvoltage Category OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current ................. ............ ........ 15 ............................... ........... Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part25 Class B, IEC61000 6 2 IEC61000 6 3 ..<......IEC62109;1(class lisafe ty),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage... -......1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions WxLxH i2$x1s2x50/ 128)(152x27.5 128x152)(35/ 5xS.97x1.08 / n 5)(597x1.37 5x5.97x1.96 Weight(includincables)...................i. .............- ......_...630/1.4.... 750,1.1.!_....1.. 845/19 Input Connector MC4 Compatible MC4 / MC4 Compatible Amphenoi AH4 Double Insulated; Output Wire Type f Connector Double Insulated; MC4 Compatible MC4 / Double Insulated; MC4 Compatible AmphenolAH41.,. Output Wire Length 0.95 / 3.0 1 2 J 3.9 m / ft .Qpera�n�TemperatureRang?.,.,..<..: ........ .........................<.,,....-40.,+$5,J 4Q-+185 ,,.......,.e...��.1.��.... Protection RatingIP68 _.................................................................................. j NEMA6P" .......................- Relative Humidity .. ........... ......................................... _... ..............<<.,.. 0-100 =� Bated STC power &the module, Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER120 SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V HD WAVE Minimum String Length (Power Optimizers) 8 10 1$ Maximum String Length (Power Optimizers) ..................... 25 ZS 50 ..,.._....... Maximum Power per String 5700 (6000 with 5 25 0 6000 12750 W ........................... ..,.,,SE7600H U5). ....., Fetalis! Strings of DlfPerent Length ............ or Orlentat7ons Yes ai For detarled string sizing information refer to: http://www.sola.edge.com/sites/default/fifes/string_sizing_na.pol. I'! If is not allowed to :nix P405 with P300/P370/P400/P600JP700 in one string. .alb®Cl R"d06 solar SolarEdge Power Optimizer Module Add -On For North America ZTITIJZZMMMM • p111WO 25Vea� — Up to 25% more energy — Superior efficiency (99.5%) - Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization -• Fast installation with a single bolt — (Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety S,;,1d+ng DocuSign Envelope ID: 49A5DF15-CD2F-46D7-B67D-E86308FB8A87 a,sunrun October 30, 2019 Subject: Structural Certification for Proposed Residential Solar Installation. Job Number: 501R-244HALL; Plan Set: Rev A, Dated 10/25/2019 Client: Donna Hallewell Address: 3244 Jellison St, Wheat Ridge, CO, 80033 Attn: To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation, the existing roof structure was observed as Composition Shingle roofing over roof plywood supported by 412 Rafter @ 48" OC. The roof is sloped at approximately 18 degrees and has a max rafter span of 18' 5" between supports. Design Criteria: • 2012 International Building Code • Basic Wind Speed Vult = 135 mph (Vasd = 105 mph), Exposure B • Ground Snow Load = 30 psf After review of the field observation report, the existing roof framing supporting the proposed solar panel layout has been determined to meet or exceed the requirements of the applicable building code referenced above. Therefore, no structural upgrades are required. R city of 4� �y " ; OocuSigned by: 17F �u 4.w g'�9wn heat Ridge -� 01EFB9FE560A443_. r;48t-1 C3+c:...**"� Q� i g�ivision 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 DocuSign Envelope ID: 49A5DF15-CD2F-46D7-B67D-E86308FB8A87 asunrun- Structural Calculations for the Donna Hallewell Residence PV Installation Date: Job Address: Job Number: Scope of Work 10/30/2019 3244 Jellison St Wheat Ridge, CO, 80033 501R-244HALL These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 Structural Geometry, Live Load, Snow Load, Wind Load, & Dead Load 3 Roof (1) Framing Check 4 Roof Attachment Check, Seismic Check, & Scope of Work Engineering Calculations Summary Code: 2012 International Building Code ASCE 7-10 Snow Load: S = 30 psf Live Load: LL = 20 psf Wind: Wind Speed Ult. (V) = 135 mph PV Dead Load: DPV = 3.0 psf R — = Doeuftnedppby: 49349 i. _._... "<...:....:': ►� VOIEFBVEMOA443.,. Exp. = B 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.383.0993 DocuSign Envelope ID: 49A5DF15-CD2F-46D7-B67D-E86308FB8A87 rro Address: 3244 Jellison St Wheat Ridge, CO, 80033 2 of 4 Structrure Geomet Mean Roof Height, N = 13 ft Eave Height, he = 8 ft Buiding Length, L = 68 ft Building Width, B = 30 ft Module Area = 20 ft' Roof Pitch, 0 = 18 degrees Live Load: 1.00 Roof Live Load, Lr = 20.00 psf Equation 4.8-1 Snow Load: Ground Snow Load, pg = 30 psf Fig. 7-1 Snow Importance Factor, h = 1 Table 1.5-1 Thermal Factor, Ct = 1.1 Table 7-3 Exposure Factor, Ce = 0.9 Table 7-2 Roof Slope Factor, C5 = 1.00 Figure 7-2c Flat Snow Load, Pf = 20.8 psf Equation 7.3-1 Sloped Roof Snow Loads, N = 20.8 psf Equation 7.4-1 Is the width of the roof > 20ft? Yes Drift Height, hd = 1.44 ft Figure 7-9 Roof slope for a rise of one, S 3.08 Unbalanced Width = 6.71 ft Fig 7-5 y = 18 pcf Equation 7.7-1 Unbalanced Snow Load = 35.44 psf Fig 7-5 Wind Load: Basic Wind Speed (3s -gust), V = 135.0 mph Figure 26.5-1A Uplift (0.6W) Downward (0.6W) Building Occupancy Category = 2 Table 1.5-1 Exposure Category = B Sec 26.7.3 Topographic Factor, Krr = 1.00 Equation 26.8-1 Adjustment Factor, X = 1.00 Figure 30.5-1 Edge Zone, a = 3.00 ft Figure 30.5-1 Zone 1 (psf) Zone 2 (psf) Zone 3 (psf) Pnet = 0.6 x T x KZT x Pnet30) _ -11.64 Pnet = 0.6 x A x KZT x Pnet30) = 9.60 Dead Load: Roof (1): -19.14 -28.74 Equation 30.5-1 9.60 9.60 Equation 30.5-1 Roof Walls - Exterior Composition Shingle 3.0 psf Wood 5.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 4x12 Rafter @ 48" OC 3.0 Gypsum 3.0 Misc. (Ceiling, Insulation, etc.) 1.0 Misc. (Insulation, etc.) 2.0 PV System, Ppv 3.0 Total Roof DL = 12.0 psf I Total Wall DL = 12.0 psf 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 DocuSign Envelope ID: 49A5DF15-CD2F-46D7-B67D-E86308FB8A87 T n1 Address: 3244 Jellison St Wheat Ridge, CO, 80033 3 of 4 Roof (1) Framine Check: Roof Framing = 4x12 Rafter @ 48" OC Timber Species = Doug Fir -Larch #2 Max Beam Span = 18.42 ft b = 3.5 in d = 11.25 in Moment of Inertia, Ix = 415.28 in Section Modulus, Sx = 73.83 in' Bending Stress, Fb = 900 psi Elastic Modulus, Emin = 580000 psi Wood Adjustment Factors: PV Tributary Width, Wpv = PV Tributary Length, Lpv = PV Tributary Area, At = PV Dead Point Load, PD = Ppv x At = Roof Distributed Load, wDL = Load Case: 0.6DL + 0.6W (CD = 1.6) Roof Zone = Pup = Pnet x At + 0.6 x PD x cos(6) = Mb(wind_up) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF xCfu XCi xCr = Mallowable = Sx X Fb' (wind) = Load Case: DL + 0.6W (CD =1.6 Pdown = Pnet x At + PD x cos(9) = Mb(wind_down) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCi XCr = Mallowable = Sx X W (wind) = Load Case: DL+0.75(0.6W)+0.755 (CD=1.6 Roof Snow Distributed Load, wSL = Psnow = Ps At = Mb(wind_snow) = Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCi XCr = Mallowable = Sx X Fb' (snow) = CD (Wind) CD (Snow) CLS CM Ct 1.60 1.15 1.00 1.00 1.00 CL CF Cfu Ci Cr 1.00 1.10 1.00 1.00 1.00 3.30 ft 4.0 ft 13.2 ft' 38 Ib 34 plf 1 131 Ib -813 Ib -ft 1584 psi 9745 lb -ft > -813 164 Ib 3565 Ib -ft 1584 psi 9745lb-ft > 3565 83 plf 261 Ib 5673 Ib -ft 1584 psi 9745lb-ft > 5673 Load Case: DL + S (CD =1.15) Roof Snow Distributed Load, wSL = 83 plf Psnow = Ps x At = 261 lb Mb(snow) = 5291 lb -ft Fb' (snow) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCi xCr = 1139 psi Mallowable = Sx x Fb' (snow) = 7004 Ib -ft > 5291 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 OK OK OK OK ow of wheat Ridge t ivision DocuSign Envelope ID: 49A5DF15-CD2F-46D7-B67D-E86308FB8A87 rrn Address: 3244 Jellison St Wheat Ridge, CO, 80033 4of4 Rafter Attachments: 0.6D+0.6W (Zone 2) Pupm = At x Pnet = 230 Ib Connector Uplift Capcity per SnapNRack Test Results = 604 Ib 5/16" Lag Screw Withdraw[ Value = 266 Ib/in Lag Screw Penetration = 2.5 in Allowable Capacity with CD = 1064 Ib Seismic Check: > 230 OK Table 11.2A- NDS > 230 OK %increase = (Motal + Warray) / Wtotal = 38782 "100%-100% = 4.32% " 37176 "The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scone of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. C'h/ of wh�4/ R'a9e in 9 �n 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 Existing Dead Load: Solar Dead Load: Aroofexisting = 2040 ft2 Wpanel = 42 Ib Wroofexisting = 18360 Ib NUmpanel = 31 Awallexisting = 1568 ft2 Wpanel_tot = 1302 Ib Wwallexisting = 18816 Ib Wbos = 304 Ib Wtotal = 37176 lb Warray = 1606 lb %increase = (Motal + Warray) / Wtotal = 38782 "100%-100% = 4.32% " 37176 "The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scone of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. C'h/ of wh�4/ R'a9e in 9 �n 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 9765W DC, 760OW AC • ALL WORK SHALL COMPLY WITH IBC 2012, MUNICIPAL CODE, AND ALL SOLAR MODULES PV -1.0 COVER SHEET • MODULES: (31) LONGI GREEN ENERGY TECHNOLOGY CO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SE SERVICE ENTRANCE PV -2.0 SITE PLAN LTD: LR6-60HPH-315M • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV -3.0 LAYOUT • INVERTER(S): • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. MAIN PANEL (1) SOLAREDGE TECHNOLOGIES: SE760OH-US WITH • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY MP PV -4.0 ELECTRICAL REVENUE GRADE METERING GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. PV -5.0 SIGNAGE • RACKING: SNAPNRACK RLU; RL UNIVERSAL, MOUNT KIT, • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SNR MOUNT SEE DETAIL SNR -DC -00369 • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SP SUB -PANEL SNR MOUNT & SKIRT • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. LC PV LOAD CENTER CHIMNEY • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ATTIC VENT • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). SUNRUN METER t�. FS-1 • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.94 AMPS MODULE SHORT CIRCUIT CURRENT. FLUSH ATTIC VENT • 15.53 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. DEDICATED PV METER ISRPVC PIPE VENT • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INVERTER(S) WITH ® METAL PIPE VENT INV DC LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION INTEGRATED �,,.,,�,t„ �„•r•. _ Son ew•ex„b•-• - ^�,,,�,,, -------r•°ssw+r+N>��ws.r..° DISCONNECT AND AFCI ® T -VENT °`~r"" °' . ,�...�,a,,,,ra,,,,,.,,r,. '..` "" • AC AC DISCONNECT(S) �.. SATELLITE DISH �`- ,>K9 saulllltxa fulN �. 11 DC DISCONNECT(S) FIRE SETBACKS II 0 COMBINER BOX HARDSCAPE -1 Q3A0H,1-. Approval Notes: F- __1 INTERIOR EQUIPMENT — PL— PROPERTY LINE 1)Verify or provide supplemental ground rod or LE :11 SHOWN AS DASHED SCALE: NTS aNs...w���{iQ :j707iT r A rods per 2017 NEC Art. 250.53(A)(2). 2) Natural Gas piping to be bonded s per 2017 NEC sunrun A AMPERE -' r r G Art. 250.104(B). 3)Bond P/V panels to the building Grounding AC ALTERNATING CURRENT Flertrodp Svstem nPr 2077 NFC Art. 690fA1. AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH Z VICINITY MAP COMP COMPOSITION EC #7080j—&93 DC DIRECT CURRENT (E) EXISTING 6040WEST9ISTA N INSTER,00 1 303.577.6 EXT EXTERIOR PHONE FAX 303.577.9629 � O 5 y _ s h Cay of NG NT I NE RIIOR S NC Fast wo body - q l W�1c3t�2 LBW LOAD BEARING WALL DONNA H COmmulvmr Dev Lcwm� MAG MAGNETIC 3244 JELL w3s,na,,e w '~ 3 APPROVED MSP MAIN SERVICE PANEL RIDGE, C olu (N) NEW Reviewed for Code CompHaM NTS NOT TO SCALE TEL. (303) 2 - 90 OC ON CENTER APN #: 9400 HOVE 6APrtST CHURCH PRE -FAB PRE -FABRICATED UMBBQ: PROJECT N I Jot PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC 501 R-24 WW Ir ON -1 DESIG R 5) 580-6920 ex3 Vlan; . iJmmer Daft TL TRANSFORMERLESS lalidrty 'hr:.<+rcrxe TYP TYPICAL AMIT MAHAJAN or pe. mrt oJv aermtor gfpppl o/�^s 0lriAt°Wrs "Iti wtrxavermilro, orun°PP-ofof.a►'w kw,!, V VOLTS - o"y oft`c f -11f-11-1 of the ' Utidirp Code a of., Cgr o,"w n.►t,.,t; W WATTS SHEET odesorothe%c,Cinorcee jrhary°� rot be � alM�tlt+1N� COVER SHEET REV NAME DATE COMMENTS REV: A 10/25/2019 r PAGE PV -1.0 d ARRAY TRUE MAG PV AREA SITE PLAN - SCALE = 1/16" = 1'-0" PITCH AZIM AZIM (SQFT) AR-01 18° 287° 98° 559.3 ® PC 2 PC Pt FIRE SETBACKS - P( (T TYP) a aJ (N) ARRAY AR-01 --- a (E) GATE L M� aJ INV � PM � SE � Q sunrun EC #7080, ME #30603 a 6040 WEST 91ST AVENUE, WESTMINSTER, GO 80031 PHONE 303.577.6527 FAX 303.577.9629 (E) RESIDENCE CUSTOMER RESIDENCE: ° DONNA HALLEWELL n 4 a 3244 JELLISON ST, WHEAT RIDGE, CO, 80033 TEL. (303) 234-1190 a 4 A 0% APN #: 94008 �;. PROJECT NUMBER: Pc �n6atti�d9� 501 R-244HALL 415 580-6920 ex3 PC a. '.- a • . ° it�aQ,J DESIGNER: ( ) AMIT MAHAJAN JELL/SONS% °d 4' QJ a 4 SHEET ° -- (E) DRIVEWAY SITE PLAN pt . REV: A 10/25/2019 PAGE PV-2.0 )ocuSign Envelope ID: 49A5DF15-CD2F-46D7-B67D-E86308FB8A87 ROOF TYPE MOUNTING DETAIL ROOF HEIGHT AR -01 COMP SHINGLE - RLU RL UNIVERSAL, MOUNT KIT, SEE DETAIL 1 STORY SNR -DC -00369 131 - AR -01 - SCALE: 3/16" = V-0" PITCH: 18° AZIM: 287° ROOF FRAME EXPOSURE MATERIAL EXPOSED WOOD FRAME TYPE 4X12 RAFTERS MAX FRAME OC ROOF EDGE MAX PEN MAX MOD. DESIGN CRITERIA SPAN SPACING ZONE SPACING OVERHANG MODULES: LONGI GREEN ENERGY TECHNOLOGY CO LTD: 18' - 5" 48" 3' 4'- 0" 2'- 0" LR6-60H PH -315 M MODULE DIMS: 66.26" x 39.21" x 1.38" (36mm) MODULE CLAMPS: Portrait: 14.6" - 18.5" Landscape: 5.9" - 9.8" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30 PSF —3'— WIND SPEED: 105 MPH 3 -SEC GUST. S.S. LAG SCREWS: 5/16"x5.0": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER INSTALLERS 3' SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. PENETRATION SPACING: FULLY STAGGERED B E3 ROW SPACING: 0.75" BETWEEN ROWS SPACING: — iCOLUMN 0.75" BETWEEN COLUMNS ow 01 whool V490 SEE SITE PLAN FOR NORTH ARROW sunrun EC #7080, ME #30603 6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 PHONE 303.577.6527 FAX 303.577.9629 CUSTOMER RESIDENCE: DONNA HALLEWELL 3244 JELLISON ST, WHEAT RIDGE, CO, 80033 TEL. (303) 234-1190 APN #: 94008 PROJECT NUMBER: 501 R-244HALL DESIGNER: (415) 580-6920 ex3 AMIT MAHAJAN SHEET LAYOUT REV: A 10/25/2019 PAGE PV -3.0 120/240 VAC SINGLE PHASE SERVICE O UTILITY GRID METER #: XCEL D1203564 SUPPLY SIDE TAP riprTroop',vttpm npr 70'17 NFC Art 690W. CONDUIT SCHEDULE 1 EXISTING 150A (N) LOCKABLE [VISIBLE OPEN] SOLAREDGE TECHNOLOGIES: 1 NONE C MAIN BREAKER BLADE TYPE (N) LOCKABLE SE760OH-US WITH REVENUE (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 FUSED AC (N) DEDICATED BLADE TYPE GRADE METERING (1) 8 AWG THHN/THWN-2 EGC/GEC 4 1 (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 DISCONNECT PV KWH METER AC DISCONNECT 7600 WATT INVERTER JUNCTION BOX PV MODULES 4 4 3 2 OR EQUIVALENT LONGI GREEN ENERGY TECHNOLOGY .— EXISTING «il _ / CO LTD: LR6-60HPH-315M 200A ,��.�. 0 ---Q `� -• $— I + (h// (31) MODULES �� MAIN VO % — OPTIMIZERS WIRED IN: FACILITY PANEL 40A FUSES (1) SERIES OF (15) OPTIMIZERS LOADS FACILITY SQUARED 240V METER SOCKET SQUARE D LOAD RATED DC DISCONNECT (1) SERIES OF (16) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS D222NRB 200A CONTINUOUS DU222RB WITH AFCI, RAPID SHUTDOWN P320 Approval Notes: 1 WITH LEVER BYPASS 3R, 60A,2P COMPLIANT 1)Verify or provide supplemental ground rod or )VAC [MAX 10' FROM 120/240VAC rods per 2017 NEC Art. 250.53(A)(2). UTILITY METER] [MAX 10' FROM UTILITY METER] 2) Natural Gas piping to be bonded s per 2017 NEC [READILY ACCESSIBLE MEANS Art. 250.104(B). FOR RAPID SHUT DOWN] 3)Bond P/V panels to the building Grounding riprTroop',vttpm npr 70'17 NFC Art 690W. CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPH-315M: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: P320 OPTIMIZER CHARACTERISTICS: SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: MIN INPUT VOLTAGE: 8 VDC 16 V MAX INPUT VOLTAGE: 48 VDC 315 W MAX INPUT ISC: 11 ADC 40.6 V MAX OUTPUT CURRENT: 15 ADC 33.7 V 9.94 A SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: 9765 W SYSTEM OPEN CIRCUIT VOLTAGE: 16 V SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 24.41 A SYSTEM SHORT CIRCUIT CURRENT: 30 A NOTES TO INSTALLER: • 16 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. • CONNECT SYSTEM VIA METER LUG ADAPTER ON SUPPLY SIDE CONDUCTORS IN UTILITY METER ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED. • FIELD SPLICE WIRE TO APPROPRIATE SIZE FOR MANUFACTURE TERMINATION SPECIFICATIONS WHEN NEEDED. • WIRE UPSIZE AT TIME OF INSTALLATION IS PERMISSIBLE. Gyri of ,,mooY�`d90 -^ &WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) 21WARN ING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC I�WARNING ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): NEC 2017: 690.5(C), NEC 2014: 690.5(C), NEC 2011: 690.5(C) &WARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS SYSTEM J LABEL LOCATION: \LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) 705.12(D)(4) &WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017:690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2017: 690.54, NEC 2014:690.54, NEC 2011: 690.54 3.5" INVERTER 1 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2017: 690.53, NEC 2014:690.53, NEC 2011: 690.53 LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2017:690.12, NEC 2014:690.12, NEC 690.56, IFC 2012: 605.11.1 6"-- -- --- SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(8), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR PANELS ON ROOF SERVICE ENTRANCE AND PV JIIIL INVERTER (EX�) 011ifl BREAKER DISCONNECT LAC DISCONNFpje AC DISCONNECT ngD;V�,° PV PRODUCTION METER 3244 JELLISON ST, WHEAT RIDGE, CO, 033 SNAPNRACK RL UNIVERSAL FLASHTRACK COMP MOUNTING EMBED OY16" UMBRELLA LAG SCREW 2-1/2" INTO THE ROOF STRUCTURAL MEMBER / RAFTER FOR TORQUE SPECIFICATIONS SEE INSTALLATION MANUAL OY16" S.S. UMBRELL LAG SCREW 2-Y2" MINIMUM EMBEDMENT FLASHTRACK COMP COMP FLASHING SLIP FLASHING UNDER SHINGLE ABOVE ROOF RAFTER (TYP.) ROOF ATTACHMENTS SHALL BE EMBEDDED INTO ROOF RAFTERS OR OTHER STRUCTURAL MEMBERS OY16" S.S. UMBRELLA I COMP FLASHING (HATCHED) ROOF SHEATHING, UNDERLAYMENT, AND ROOFING MATERIAL (TYP.) Sunrun South LLC DESIGNER: BYETERSON 5fl\(K\3UpNr(ack- 595 MARKET STREETNE (415) FLOOR • SAN FRANCISCO. CA 94505 USA DRAFTER: D, RYAN PHONE (475) 5806400 •TAX (415) 580-6902 RE RODUC ION, INTMSDRE.ORUS THEREOF TIALISP OHWEND PRIETARY. ANY APPROVED BY: B.PETERSON REPRODUCTION, DISCLOSURE. OR USE THEREOF SOUTH LC. WTiliOUT THE WRITTEN CONSENT OF SVNRUN SOUTH LLC. DETAIL A 1BRELLA GASKET AADED GRAY) OF SHEATHING FLASHING SHOULD NOT EXTEND PAST END OF SHINGLE COURSE INTO RAFTER OR STRUCTURAL MEMBER REVISION: 5/1/2019 ill QUAIL R COMPLETED INSTALLATION SECTION VIEW FLASH TRACK SHOULD BE INSTALLED PARALLEL TO RAFTER COMPLETED INSTALLATION SCALE: NTS DRAWING NUMBER: DESCRIPTION: SNR -DC -00369 DATE: 5/1/2019 ROOF DECKING City of viheai Ridge . -.IA!nCl Divis+o� REV: RL UNIVERSAL, ATTACHMENT DETAIL, i FLASHTRACK ON COMP 1 2r�t%JgC6v INSPECTION R INSPECTION ONLINE FORM: htt :// RECORD INSPECTION REQUEST LINE: (303) 234-59spection Cancellations must be submitted via the online form before 8 a.m the d f 33 t Occupa�ncv_ /Ty,p • ay o the inspection Inspections will not be performed unless this card is posted on t **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the followin be project site. Inspector Must sign ALL spaces pertinent to this project g business day.* Foundation InspectionsDate p Ins ector Pier Initials Comments Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not our Concrete Prior To Approval Of The Underground/Slab Inspections Date Inspector Above Inspections Electrical Initials Comments Sewer Service Plumbing Do Not Cover Under round or Below/In-Slab Work Prior To A Rough Inspections Date royal Inspector Of The Above Ins Wall Sheathing Initials Comments Mid -Roof Lath / Wall Tie Rough Electric "' Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Inspector Landscaping & Date Parking /Planning Dept. Initials Comments ROW & Drainage / Public Works Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking Floodplain Inspection (if applicable) inspections call 303-235-2846. For ROW and drainage Fire Inspection / Fire Protection Dist. inspections call 303-235-2861. For fire inspections Final Electrical contact the Fire Protection District for your project. Final Plumbing Final Mechanical Roof Final Window/Doors / �l Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building Of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization 'For low voltage permits —Please be sure that rough inspections are from the Fire Distr' before a Certificate 'y the Building Division, completed lori occupancy. ict and electrical low voltage Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issue Protect This Card From The Weather d ons ZMIT NO: 3 ADDRESS: 3 DESCRIPTION City of Wheat Ridge Residential Roofing PERMIT - 201705980 ��LAI - ISSUED: 08/12/2017 201705980 EXPIRES: 08/12/2018 3244 Jellison ST stall asphalt shingles - 19 sq Residential Re -roof to in Malarkey * CONTACTS *** NER (303)42-7531ANTHONY W B (303)5- John Borfitz 019983 J & K Roofing Inc. *** UA / Unassigned * PARCEL INFO USE: 0 / )NE CODE: UA / Unassigned ME BLOCK/LOT#: 1RnTVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ESTIMATED PROJECT VALUATION: B, Otsb. uu ** FEE SUMMARY *** FEES 0.00 otal Valuation 169,81 se Tax 188.45 ermit Fee 358.26 * TnTAL ** ** COMMENTS *** require an approved midroof *** CONDITIONS *** 2014, asphalt shingle installations req prior to final percent of the roof covering is installed, p Effective December 1, inspection, conducted when 25-75 p new or overlay) is required on the entire roof with ANY gap exceeding one half inch exists. Sheathing and approval. Installation of roof sheathing ( ercent of the sheathing when spaced or board sheathing one hundred p les are required be be called in at the same time, be complete. Asphalt Shing mid -roofs may per shingle. Ice and water shield complete and 25-75 percent of the mid -roof may required. A ladder extending 3 feet above the roof eave to be fastened to the roof deck with a minimum of 6 nails p 3feet inspections. Roof ventilation is required. Eave and rake metal is req provided for all roof and secured in place is required to be to comply with applicable codes and/or manufacturer installation instructions, is required ent. In order to pass a final inspection of elastomeric or similar whichever is more string inspection and approval from the manufacturer technical a letter of address) has been type roof coverings, that the application of the roof at (project representative stating lied in accordance with the instasite1at the ttime lof finalrinspection. rial brand name of mat app is required to be on roof covering" required, the 3rd art inspection will be req Cit of ort will be collected at final roof inspection performed by Y Roof inspections for ROOFS OVER 6/12 PITCH: 3r P completed party inspection rep wheat Ridge. If report is not available the final inspection will not be 1* � 4 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 416cl 0 Job Address: X244' c Tr --i A F Permit Number: -;?0(70!�2_Q ❑ No one available for inspection: Time AM/ISM Re -Inspection required: Yes No,. When corrections have been made, call for re -inspection at 303-234- Date:-/Q& 03-234-Date:JQ Inspector: DO NOT REMOVE THIS NOTICE A i City of Wheat Ridge 1 Residential Roofing PERMIT - 201705980 9 PERMIT NO: 201705980 ISSUED: 08/12/2017 JOB ADDRESS: 3244 Jellison ST EXPIRES: 08/12/2018 JOB DESCRIPTION: Residential Re -roof to install Malarkey Vista asphalt shingles - 19 sq *** CONTACTS *** OWNER (303)234-1190 ANTHONY JOHN W SUB (303)425-7531 John Borfitz 019983 J & K Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,086.00 FEES Total Valuation 0.00 Use Tax 169.81 Permit Fee 188.45 ** TOTAL ** 358.26 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201705980 PERMIT NO: 201705980 ISSUED: 08/12/2017 JOB ADDRESS: 3244 Jellison ST EXPIRES: 08/12/2018 JOB DESCRIPTION: Residential Re—roof to install Malarkey Vista asphalt shingles — 19 sq I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I amlegally authorized to include all entities named within this document as parties to the work to be per o ed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER 'Jor CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable co ny ordinance oulat'op this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett From: no-reply@ci.wheatridge.co.us Sent: Tuesday, August 8, 2017 5:01 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Dane Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) L 3244 Jellison t. John Anthony 303-234-1190 �l c—a Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Anthony Contract.pdf Contract CONTRACTOR INFORMATION Contractor Business J & K Roofing Name Contractor's License 019983 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) 303-425-7531 13000 W. 43rd Dr., Golden Co 80403 Contractor Email Address kathyv@jkroofing.com Retype Contractor Email kathyv@jkroofing.com Address DESCRIPTION OF WORK TOTAL SQUARES of 19 / the entire scope of work: Project Value (contract 8086 value or cost of ALL materials and labor) Are you re -decking the No roof? 2 Does the scope of the project include a flat roof (less than 2:12 pitch)? Does the scope of the project include a pitched roof (2:12 or greater pitch)? How many squares are part of the pitched roof? Describe the roofing materials for the pitched roof: Type of material for the pitched roof: Provide any additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) No / Yes 19 Malarkey Vista Asphalt House - Pitch 3/12 & 4/12 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. Yes Yes Yes 3 I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Kathy Vendegna Email not displaying correctly? View it in your browser. CONTRACT AK Roofing [WEI 3000 W. 43rd Drive Golden, CO EINM Mut-d: 3C(3 -42!3 -?3S1 • rax! 333-425'SF.2 •CAw- Representative M'i -�— i;ont3.ct_ 1 - �-- ��0 Date —�� 20- Nan -id _ Hft'_ Le 1!3--->3'L—LLL — Bm�il_ .ID�►�id4�[irA�l� arlh� i40, S1 Address -3'a 9- j-&0^*i PirnkiLyy ftgj nrcr. 145xKc•vCurypgiWcn r-turarce %'t.V PAEY79MU LA i)Ft AMID MAT RIAL rLQlF:IGAYIGM_TERPA% AND W 01TIQA& Pr+4% BE&D reAFtF.ELILMJ4LY' .ems A V sk-+r c lois 3► eRkz�.-Xof with 30 WM41�rok r m leg 1"r ;i O w1 gm _ Colo of -,r•, g t - jl�Tear o f .0 Install ummnayrrrent Ra•Ff<isf,{:h-rinayea IR igbta .:ce- ,��+h:w SPrrUega _ Hepi%m Riciy4_ � 4 Gulvanlikl Frstlarcr3 INCL, 1.'&'! — �aepr� .� � �,4xr�rrr3 J4:rks 4:5: Panl roM 9=k:E :o —at r. Install _ Metsl Edgirg An C mofS- 46,PfftiG 064 mt roof W Year V k&wily on labor {+ J & K Roofing to iurrtiah all rrtjrerial and labra 4Fermit: _0-31 InwlU od (JCT lnciLr;tMF GWA-.rp detxib W0 nazi off all 1rilsh IrGm rou I 014)!1 -yard willi magnetic roll -ere Gt tl t cleared o: r1w,19 dabri5 Decking RuW. es S per - :3 Hiduicl La gs "ar 01) S_ _ cC� Iar1j?W Ce•'-iAM-Ca1M =1 EMbw city _ �'tJ zip ? C rl:lf 9eAI $I,rx:lxl.y U'�db'u•r err• 9es-t;;�3nr,¢s 0kergral Liaullt4 I-surcnrv! y, polio ,$L1U_8 7t'I p Extra work0 •L4 -n" �'+" t rLQ>r►+y�. Q'�fr1+tJ-. � ' �� �'L'4D SJR fE 4•r 1,.e S I ne prop -ly owner i is rat _ -is 1N proceeds from ptvciery ana czw1 11ty Invxencu pollc,- r,wuctiale i= irppucahle $_ Per Colorado 9tatt Law OR606-22-1103 whiab states; 100% the reBPun3ibY11y at the tt*vnaownsr t4 past this amount J 8r K RdoMW will not MIMburse'Or pMmise to r*mburee in Whols' OF In part any amount WjhededucUble. Ea:ima W 3%Arl Dime 5- 6 we4 TOTAL EGTIr.AATE .il l PPO:PO LS ARE E!jj9JECTTO 61MA3EMFNTAW0,01'iA Yom hawe tba Mght to resh d 4rls cormac4 and dbtoir a !Lily rl➢amcr of awl 4 Prxr t 04ha 7 74.MWP WhT olowng �o �baCt If you PM1 to use the prg—lft ftM a ppperty and Ow"Itg insurance poliGY too PEY fM the �4ng vMritl you may rescind thle Ctalrpraet wiIhIM 72 hours alter reCvivh,0 MtttWn,,6 * ftV ypur ineurftce r�vrier%at your Clairn has bean denied itiy heila Or in psrL Howevor, JA K hoofing is erittled tg retail p4LM40frht or deposits %cornponw a for rootlng vrark atUualllr l9f m ed In a workrMalike nwwgif [Wn9i8DiB d WW th standard roofing P•eClIeee. PLEASE SEE REVERSE SIDE FOR IMPORTANT IMFORMA'TION .1 &K Ggec Hcareadifur_. 4a�)_Deft rL j ljpT^.d��Tltl' � j� •anion f Ex3 Wtp Yom hawe tba Mght to resh d 4rls cormac4 and dbtoir a !Lily rl➢amcr of awl 4 Prxr t 04ha 7 74.MWP WhT olowng �o �baCt If you PM1 to use the prg—lft ftM a ppperty and Ow"Itg insurance poliGY too PEY fM the �4ng vMritl you may rescind thle Ctalrpraet wiIhIM 72 hours alter reCvivh,0 MtttWn,,6 * ftV ypur ineurftce r�vrier%at your Clairn has bean denied itiy heila Or in psrL Howevor, JA K hoofing is erittled tg retail p4LM40frht or deposits %cornponw a for rootlng vrark atUualllr l9f m ed In a workrMalike nwwgif [Wn9i8DiB d WW th standard roofing P•eClIeee. PLEASE SEE REVERSE SIDE FOR IMPORTANT IMFORMA'TION i CITY OF WHEAT RIDGE �9�(303) Building Inspection Division_: (303) 234-59331nspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: `�`l Permit Number: -2/)/�3 ❑ No one available for inspection: Time 9 '/ AM/,.PM Re -Inspection required: Yes No When corre ctions have been made, call for re -inspection at 303-234- Date: Inspector: DO NOT REMOVE THIS NOTICE of Wheat Ridge IV V 1�9r Faxed Plumb. Permit PERMIT - 201400878 PERMIT NO: 201400878 ISSUED: 06/23/2014 JOB ADDRESS: 3244 Jellison ST EXPIRES: 06/23/2015 JOB DESCRIPTION: Install 50 gallon hot water heater. *** CONTACTS *** OWNER (303)229-0888 ANTHONY JOHN W SUB (972)655-8080 Svetlin Tchakarov 1..301..33 Prospect Plumbing, LLC PARCEL INFO ZONE CODE: UA / Unassigned USE: SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 FEE SUMMARY ESTIMATED PROJECT VALUATION: 1,284.00 FEES I Hot Water Heater 40.00 Ta a Total Valuation 0.00 Use Tax 23.11 ** TOTAL 63.11 COMMENTS a d re a ha k e e o .. ed sh all a f es 0 'ic P It 'co s 0 0 b "es' t 'or �o ' P a "Ici a 0 y " a e P "e m aut 0 t r t n ature, codes all a a pplicable b Te oNvne 0 the rope and at aill s th , t d I I f to m aut jonzed inc a I p Pe C. I furthe attest that I any l ega lly i a that t 11w to P orm s t s 0, Chic a a a rk be er� ed d ed n oc Sig nature cif OWNER or CONTRACTOR (Circle one} Date NO= FA a M411012 AddQ if dftmt Man pmpeity addrws) ♦ i CITY OF WHEAT RIDGE Bung Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: {GJ C ~a S7 Permit Number: / 5. ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No * When corrections have been made, ca0 for re-inspection at 303-234-5933 j Date: ' /r' Inspector: DO NOT REMOVE THIS NOTICE r A e ` CITY OF WHEAT RIDGE Bung Inspection Division J~ (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE 4 4- Job Inspection Type: G e~ C, Address: j- Permit Number: YES ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, calf for re-inspection at 303-234-5933 Date: 21 G' Inspector: OT REMOVE THIS NOTICE ♦ ! i CITY OF WHEAT RIDGE Bung Inspection Division (303) 234-5933 Inspection line J (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ~h6~ f, Job Address: 4~\Scl~ Permit Number: 0'~~44~ ❑ No one available for inspection: Time 1 cAt 1 S AM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date`: f~ Inspector: dt~! DO NOT REMOVE THIS N TICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line ]~~'r(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: PW. 1lOtJ\ Job Address: 3~ ~~S tilt Permit Number:L c ` ❑ No one available for inspection: Time Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: -,)-I I loo Inspector: { DO NOT REMOVE THIS I OTICE ~oF "'"E?r9o City of Wheat Ridge Building Division Date: m 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Plan ootolxnao Inspection Line: 303-234-5933 Permit 110P/~~ r5214 Building Permit Application Property Address: = ~ 2 G7( Property Owner (please print)): ®Q,,,~lq AL j G t~t~ L Phone: 3cD-3 a z, Mailing Address: (if different than property address) Address: -5~ City, State, Contractor: /77-x- 1A r 6 r Contractor License m D~ Phone: ?e3 C,;7/ Sub Contractors: Electrical City License Company: Plumbing City License Company Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): t:7- Construction Valuer $ a C1~" Description of work: (as calculated per the BuildinpData sheet) f DGyn / -/1 /r7 C~-Ap I Plan Review (due at time of submittal): $ Sq. Ft./L.Ft added: Squares fE BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESE IVE of (OW (CONTRATOR) PRINT NAME; ~j / 77t/)rE~? SIGNATURE: _ Date: Bldg Valuation: $ COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: 324'7' JIELL/SOA/ .5'"/ ~ 0/;-: /;> //Le @ ~o,;(/T /,/"o~~ /5 /V6/4#A-'/'~ When corrections have been made, call f re-inspection at 303-234-5933. Date0 -/c?-Cl S DO NOT REMO\li Inspector Building Permit CITY OF WHEAT RIDGE 7500 West 29TII Avenue Wheatridge, CO 80033 303-235-2855 Permit Number J9370 10/19/2005 Inspection Line 3D3-234-5833 . Residential Roofing PROPERTY 3244 Jellison St OWNER: John Anthony Unit: (303) 234-1190 Description Install 7/16 OSB oVer entire roof, install prepainted flashing and new 60 mil folky adhered EPDM roof, IFEES IFees IUse Tax IPermit Fee ITotalFees 1 ICONTRACTORS IName ITiley RoofinQ Inc, I IPaid 1$84,82 1$144,70 1$229,52 1 I IPhone 1000426-7370 1 IDue 1$84,82 1$144,70 1$229,52 1 1 ILicense # 121395 '(=>fI{1--PVOI pU1M. H4Y'l sn$ PUO;)8S-8alljl H4Y'l au 06) =>fI1--1 pU1t1\. a(\Vlj Sp7!-I81VU/ ?JuifOOJ 18~U/ 01 p~W}ISUl ~SUl fo(}.l. looif JOf ~I1SUG tft:JOOS l1:J1ljAt u~~~~VlU 'aul wo.if sluawn:Joa aq /lvljs JatT!PI1j-'"u .. Units: OccupanCy: Walls: Roof: Stories: Sq Feet: o I her.ebycertify that the iielback distances proposed by this pennit application are accurate, and do not violate applicable ordiniinces, rules or r'egulationsofthe City of Wheat Ridge or covenants, easements or restrictions of record; that aU measurements sllown, and allegations made are accurate; that I have read and agree to abide by an conditions printed on this application, and that I assume full responsibility for cmnpliance wIth the Wheat Ridge Building Code (U;B.C.) and all other appllcable Whe~1ge or~ina work under this pennit. {tVl . toll'1/oOS:- (OWNER)(CONT SIGNED DATE This permit Wll.'lissued in accordance with the provisions set forth in yoUr application and is suhjeCt to the laws oflhe State of Colorado 'and to tbe Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shaUexpire if(A) the work authoriud is nol commenced within siXty (60) days from issue date.or (8) tbebuildlng authoriied issuspendedor abandonedforaperiodof120days. Ifthi5 pennltexpires, a new pemtit mily be acquired for a fee of one-half the amount normally required, provided no changes have been orwillbemade hi the original plans and specifications and any suspension or abandonment hll.'l not exeeeded one (I) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid fora new penult. 4 No work ofany manner slulll be done tbat will change the natural flow of water causing a drainage problem. S Contractor shall notify the Building Inspector twenl)'-four (24) hours in advance for all inspections and shall receive written approval on inspeCtion card before proeeedingwithsuccessivephilsesofthejob. 6 SIGNED DATE Chief Building Inspector Wednesday, October 19,2005 Page 1 of 1 . '--- COMMUNlTYDEVELOPMENT DEPARTMENT BUn.J)ING INSPECTION LINE" 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-1855) APPLICATION Propcrtyowne~ ~ PropcrtyAddress: 32-Hl{~ W~ Contractor License No,: 021, 3'lS I .,;.-.-'\tvJ ~ '""" Company: \ i0()jf ~ J..v\{"'_ ~~ - Building Pennit Numb"", Date: Phone:,;z3 l{ I ~oto Pbone:42U 7<.1tD OWNDICO}lIt'RACTOR SlGNA'J"(I'U OF UNDERSTANnING AND AGREEMEI'lT I _by certil)o Ihslth. ,elbaclcdistOllocoP'''Posed by lhispcnnllapplication ...accwal<. Construction Value:$ '17102 -.nd do no['l,nol.te applicable ordinanees, rules orn:guladom olthe City ofWhoatlUdgc or Permit Fee:$ .covcnt.nts, easemml8 oTJ'elitrielions of reeord; tbatall melsurement6 Jbown.and .1.Ueptiom made ". Ie""""'; that I have..ad and ..... to abide by all concIitions printed O' "n, Plan Review Fee:$ JPplication and that I mumc full responsibility for COlqJli&oce with the 'Wheal Ridge BuildmgCode (U,B,C)ODd a1lol11eupplicobl. WbealRidpo..<finaucc~ Co..",rkuudu Use Tax:S .....cnroc ~ __ Total:S (O~tmlACT~GNEll ,- ~ATE~~ '> . DES~~ 11 \ lP" Do e oJU ~~ \J'\.~\c0.l f~"!W1'tlcf. ~ dNO ~ !yO ~ ~\~ &.ilivwt. It'O\'{\..~, BUll.DlNG DEPARTMENT USE ONLY SIC: Sq.Ft,: ZONJNG CO....T.: Approval: Zoning: BUILDING COMMIHTt:: Approval: P".uc WORKS COMMENTS: Approval: Occupancy: WaII$: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing Li= No; Company; Mecllanical License No: Company: Expimtion Dale: Approval: Ellpiration Date: Approval: Expiration Date: Approval: (I) Tbi. pemU1 wat iswt4ia ~ willIlb6 ptlloviricm 5ctlo\6.m ywr~__ls m1Uocc to 1N taM af1bc Stdc or Colorado IDll to tB ~ RcgWatiou and BuUdiaa Cada oCWhcat Jtid&e. ColaIam or t:lly oIbtr ippIiGtblt onliDaDcci of 1be City. (2) this permit 1hIll. ileA) tbeWOEkauth0rizt:4i1D01.comm=ccll~ mty(cSO)4aY5Ao11iilsucdlocorGl) OsIbui_~il SllIpCIdcd or ~fi:Ir",*,odorl20days. '''',' '-;'" <,> Itchili penNa .xpiJea.alllii"pfmlilruy beKClWzed.foll fee ofoaMalttbc PIIOlIDt'OOlSlllyttquilcd. ~DD ~lJt\lt Mal <<wiD be~ ill dleoriPWplauud~lUIdllllYansptZlIicmorlblndoammlhallK.l&"ceede4lm1(I)JC'f.lfcUD&"bwbccl:lCC'iC~on~a~' exctW 0" (I) year. tun feel wn be p.\hf _aDN pcnpjt. (4) No WQlkofanYmlDDa'slW1bedtmctbatwillt.blD,p iAeDltUlll flawotwalGClumtidrafDaBc problem. (S) o-tatlMlhaU'DotifYdlc8ui1diDa~~(Z4)bourI jp&dVIIICCforllllDspecliDD6aDdIW mevewria=&pprOWaltlII. iDlp<<tioa {.U\1 bdcR proceedia.a wiIb. mcuuivapbascs oClMiob. (6) 1M Ulu..mcl: tlf I permit or lbe approval ofdr&willas aDd tpe:Ci6moas s1lIlI AOI be coostnWllo be.. panrUt far.!lOt sa qaproval ot allY ViOlIbDn OUlI; ptllviJ.i.ODl of the bwdin&: oolkl OC'UlY DdlcrQnU~ IIw, ~ Or reaWlticm. Chief Building lIlspector W'd 17<;: i:I ~00i: l-Z Jew L<;8i:<;~~:X\'.:l fTkJ II 9NINNljld DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 6357 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 12/11/97 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: 3244 JELLISON ST Contractor License No,: 18145 Company: APH.ServiceCo, Phone: 234-1190 Phone: 295 6622 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: $3,400,00 $133,00 $0,00 $40,80 $173,80 I hereby certify that the setback distances proposed'by;this permit-app'lication-are acCurate, and do not violate applicable ordinances, rules or regulations of the City 'of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accura,te; that I, have, read and agree to abide,byall conctitionsprif'lted on this application, and that I assume ,full 'responsibilitY for compliaRoe(with'th!:i:_WIi"eat Ridge Building :::~~:;~~~:::::::::::e~:~O~g;:zrk~::;~h?~/)_ Description: 115 K FURNACE . Total: " """BUltDIN&-DEPAR'fMENT USE ONLY ~ Approval: Zoning: SIC: Sq, Ft: -'-_-J -- ~ Approval: ~ Approval: Occupancy: Walls: 1'_;' Stories: Residential Units: Roof: Electrical License No: 18145 Company :APH Service Co, Expiration Date: 2/28/99 Approval,: II~ Plumbing License NO: Company: Mechanical License No : Company: Expiration Date: Appr9v~t;,." ." II~ Expiration Date: Approval: 1I1.1i1D~ (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge. Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended Of abandoned for a period of 120 days. If this permit expires, a new permIt may be acquired fora fee of one-half the amount normally required. provided no changes have been or will be made in the original plans and specifiCations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a newpennit. No work of any..m ner shall be done that will change the natural flow of water causing a drainage problem, Contractor spall n 'fy the Building Inspector twenty-four (24) hou,rs il1:advance for all inspections and shaH receive written approval on inspection card before proceediing'with ..cces~ivePhasesofthel'ob". _.. ... . ','- The issupnee. of .~.rt or the approv 0 dra . gs and 'specifications shall' nofbeconstrued to be a permit for, nor an approval of, any violation of the provisions of the building d~J; 'r any othe orcl" nee, I , rule or regulation. 'l. Chief uilding Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION (4) (5) (6) :2:= ~:"-:-:.,I::::'I-:- ::= ,::~'!"mllNG ..l.NC C2j::..:::=:'.lE~7 cl:licira; :=~r.r:lt ~It.:r.:cer: olJlL':li-lG iNSPECTION DIVISION - 2:35-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 I, ~;!' Property Owner. Property Address : Contractor Ucsnse No. :' . Company: ~S Oa-nYiA Jj/JJlf,W'0)) 3'JL/L) J-t) !15()n sT Phone:' ;Z :)/ Jl Cj D ~ Phone2,qs- "~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I helllby cemty that me setbadc distances p",pased byJhis perm~ applicalian ant .=le. ana do not Violate aCPUCiilDWt ordinances. rules or regulations at the CIty of Wheat Ridge or covenants. easements or restndions at record: that aU measwements stlawn. and allegations made are accurate: tnat I have read ana agree to abide by aU conditions pnnted on this appllcallO". ana tnat I assume full reaponSlbi . tot compliance Wftt1 the W'heat Ridge Building Code (U,B,C,) .na all other applicable Wh ' nces. forwoli< undermis permit. Construction Value: Pennit Fee : Use Tax : 3Lj(TO ~ ,. < (OWNER)(CONTRACTORl SIGNED DescriPtion:'V1'sJbi! I'S~gllfftV0jPU'-1O J%"fl ~1l5 ~-l,kornc.13v.(jI(,- ) :l :if , n > , ,.j.', 2,7D BUILDING DEPARTMENT USE ONLY Total: r i 0, :i 3 wi qps 0k~iT vfrJ.' &FJ: :.i1'J1W!i.'-' -II . . 'JI' Approval : Occupancy : .....,&7 '3;; 0 '~t.il;;t:~3.'{)?:Q ....':,.i;:...... ....... "2R.', . .. ..:.':....~..;,;.:.~,~.~,L,.~,..:,}.;..:,;..,...,!,.;:!':[J;t,;,.-...~..,:,.~~,.:".;,:.-:,:..~...'....;.;,~:.'" .~-::.::;~i0~(~~~~~f~'( - ., .'.. ..... . _".:..:'::';.;/ ... ',. . ._ . .. .~ .,i; ;,. ',h~_. .. .. Approval: Zoning: BIIIlitlillP.(.....~ Approval : · ~~I.I~5o;,;.::;:,;}jt;'>~~',!,OOf". ... Stories : Residential Units : ;-~. ~lrewai'kii~pmJ'''jIL.. f""-; .. Electrical License No: J <? I~! S .f Plumbing Ucense No Company: /d P n ~--U) c.L lD .Trll,;CompanF .. .. Expiration Date: ;)1 0 0EXpiratton Oate ; Approval : ,':kprov3l : ,~ !t~:~u~ . .~, !<",.!!"'-.~Ii'Bd':::::J ~ " . Mech,anical Ucsnse No :. J q 0 3 . Company ~ /J P}~ SiA:v) l.C W 1'.1') Vq S Expiration Oate : Approval : . 1.i:';..lt~~~t~ I l~~~~ (1) (2) (3) This penmt was JUUed It! ~_ 'MUt tne pral.~_1lIt fanrtin 'fOClUI'!:II "I J I 11 and is SUCIect ta the Iawa 01 the sm. of Ccknda and tD the Zoning ReguiatlQf1sandBwidn;CoaeotWheM"fUd;&CalctacSaoranyOlMt'iPP"""".....aratft8nC8I,attn.C!ty. ':":~ '. ,.... '-""'~"':-"'" This penm snaM ago Jf (AI tnewark~~~"."":'"~::.._aawnnen_~ (~).dayatrcm_lS&UecWe ar.<B} lie tluiIdIng autnanzId" '!'.". ~0It . abandOnedfcta~ot12DcSay&..."........"!~'"':;.~....;"~..!,.iJ";..:......: u'i.-':'~" ....~::.,.. '",". .., . ;.' .-;' ".-.....-...".... . .. .-...,....;-.:....-,. Ifthio'*""'_.___...,be~ror.r.oI_1lIe_I1ClllnOIIy_pnMdodnoc:llan!l8a__"'...Ilo_..1lWt ongiMIQlansancl-r' la.a...~ ~ _.<<~~~. ..., _ ....~.(~~,.Y~~,I~.~..~<<ifsuapenaiQnOl.oa..doi...:~jl exceecsaan.(1)yeKtutlfeel:.....bepM1fQra...permlt. " .'~. -......- ,".__;;. .. __,._. '-.h__..' ". "~"_: _'''_w':'.-',,',." N"aWClKQt any ~stWI bedanelftawilcftangetnenaantaawCt......QUaing lIdrainal;.groDIem.' ~:.' .'-~ ...::.~~:.'l-:~.;~,~. ...... Canuaaor snail noctv m. BwktIng: Ift:IC)eCZtIr"~ (24) ho\n 1ft adVanCe foI' ail inlQ .. IS and ahaII receive writtM ap~ an;'. . \ cans befont . ==;:=:;=:..u.~~~.~~dw.~sha&lnatbe~~"~a_far._anappravaial.~\'iaIadQnd.th.~ at the t1UlIdlO9 COdes at arrr 0U1_ ....~__1aw;. lU&It or re;waoon. I I. '. (4) (5) (8) Chief Building Inspector ., For Mayor '." ..-.. . , ;. \"" : . .' . . . .. - . ....::~.. " THIS PERMITVAUD ONLYWHENSIGNEll BY THE CHIEF BUILDING INSPECTOR AND MAYOR .(E CA1:L=~9nZ4 HOURS PRIOR TO INSPECTION:,.,,',,;,,'jr':",,<,:"";;:";"':":: '...' .. '. .:.'--:; - '<;-'\;:' '.: .\ . :::"" ..' 0" .. . ..' :::;':'~-""';I'~:';'r>~.:~~:.' .' :.::~~:., - ",/;Y:~1f:~t; ::. '.~" :,";~.~~~..::~ . '.:.' -~. ...:~.. ..,~ . DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION. 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 2722 3nt96 Property Owner: EDLUND BRUCE L Property Address: 3244 JELLISON ST Contractor License No,: 17261 Company: Academy Roofing, Inc, Phone: 969-8033 Phone: 360-0708 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U,B,C,) and all other apPIi~1 Flidge ordinances, for work under this permit (OWNER)(CONTFlACTOR) SIGN ~/r DAT~1"')J?? Description: REROOF Total: $3,079,00 $63,00 $0,00 $46,19 $109,19 BUILDING DEPARTMENT USE ONLY ~ Approval: Zoning: ~ Approval: ~ Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval : Expiration Date: Approval: . --il..._____ III Expiration Date : Approval: .~ .~ This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Buildina Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire If (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the BUilding Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. The iss nce of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the ui ing ! desoranyo rordinan 'laW,?~n, uilding Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION (1) (2) (3) m (6) If~l~ DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: 3 f;) Ot y, Property Owner: --J oh n {+,,+I-\ 0 r\ 'I Property Address: 3;2 '+ '-I- ::Je. f II SO f) s.-+-r~e-+ Contractor License No, : / '7 2. &:, / Company: A-cMem,! Qcc.-i2t"'j LYle. Phone: q lpq- - 1S' 0 33 Phone: 3c'D-D 7 0'8; OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: ~ 0 7'/, 0 0 I hereby certify that the setback distances proposed by this permit application are accurate, Permit Fee: and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that aU measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this Use Tax: application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. Total: "(OWNER)(CONTRACTOR) SIGNED ;()()(j) 5TE/ZLINOnATE 3/7/QC, 5''' " . 1!3,os.ql.jAYe,o,. pa:,,,,,,-c\.&le.e.\ Descrrptlon: Re roof- ove.1' eK" s+i "9 w'l+h 3-f-nb s> , ~"-p\CLCe. Q..'I,:' '0,+1 (')9 '] Vv-tt-e'r BUILDING DEPARTMENT USE ONLY Approval: Zoning: ~ Approval: Rmilr_-M\1S'I _..!Iii Approval: Occupancy: Walls: Roof: Stories : Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: !:!m:~!1l!tl!~I!J~ii:il Expiration Date: Approval: ':!lll llillliifli',ieuifel:l::S:'.:l :8fiI ....:,......., !lA, ....... .,.:./~ Expiration Date: Approval: !II ~~ir~ (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized IS not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a penod of 120 days. If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. Nb work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceedling with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the bUilding codes or any other ordinance, law, rule or regulation. (4) (5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-593324 HOURS PRIOR TO INSPECTION