Loading...
HomeMy WebLinkAbout11871 W. 39th Placei CITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -� Job Address: Permit Number: rives I V l ❑ No one available for inspection: Time, �--- P1Vl Re -Inspection required: Yes�.'4ANo When corrections have been made, call for re -inspection at 303-234-5933 Date:= Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge s r Residential Mechanic PERMIT - 201900750 PERMIT NO: 201900750 ISSUED: 04/22/2019 JOB ADDRESS: 11871 W 39th Pl EXPIRES: 04/21/2020 JOB DESCRIPTION: Residential mechanical installing a gas line and pre -fabricated fire pit. *** CONTACTS *** OWNER (303)995-8575 WALSH CHRIS SUB (303)466-4206 GREG FANGER & KEVIN FANGER 017986 THE GAS CONNECTION *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,855.00 FEES Total Valuation 0.00 Plan Review Fee 48.17 Use Tax 38.96 Permit Fee 74.10 ** TOTAL ** 161.23 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and�ao b erfo ed is disclosed in this document and/or 'is' accompanying approved plans and specifications. Signature of OWNER or CON CTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying pFlans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. Z. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or aily�ordinance or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of C tef Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. FOR OFFICE USE ONLY Oily of Date: �/ `1V heat �id�gc l 1 Z///F I�k[_!NM v - ��>,m .N (t �L CLC. F, 3 Plan/Permit # Building & Inspection Services C-_� V ! ( 7500 W. 29" Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(o)ci.wheatridge.co.us Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: it p �-/ w - 3 G -� P1. Property Owner (please print): lJ1 r j S 11 JJ SIS Phone: Property Owner Email: C -,A r-; S-- kJoI5.A -- 9q a ) 4A00 U -m V Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: 0 (b �_( Ll . 3 q 4:!� f! City, State, Zip: �jJ g.i— ��� �( -0 8 UV 7 � Arch itect/Enaineer: Architect/Engineer E-mail: Contractor Name: / f'L (� t Phon City of Wheat Ridge License #: % / " 9 G Phone: ;Contractor E-mail Address: S . as to n.r t- For Plan Review Questions & Comments (please print): CONTACT NAME (please print): �� lu•�► /�,�1 /'\� (,Y Phone: ?o CONTACT EMAIL(please print): 'D`tAUG&� bt-V)J C_T 2% J0. Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R_ City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. [-]COMMERCIAL RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Sq. FULF BTUs lxi,-- -�v- -11. o t) r." Gallons Amps Squares For Solar: Kw # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that l assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNE*(CONTRAI CTOR) or THORIZLD REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: L/A' t 1 Q Printed Name: ZONING COMMMENTS: Reviewer: BUILDING DEP ENT OMM TS: Reviewer: Y 2zfcq PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: 4/19/2019 Go, .gle Maps; 11871 W 39th PI 11871 W 39th PI - Google Maps r 7lic Imagery ©2019 Google, Map data ©2019 Google 20 ft 11871 W 39th PI Wheat Ridge, CO 80033 0 Q (�) (�) O Directions Save Nearby Send to your Share phone ®� QVC9+83 Wheat Ridge, Colorado e https://www.google.com/maps/place(11871+W+39th+PI,+Wheat+Ridge,+CO+80033/@39.770836,-105.1323683,53m/data=!3m1 !1 e3!4m5!3m4!1 sOx8... 1/1 -GOLDEN FLAME- 18" LAME18" Round SS Fiore Ring Burner with 112" center gas fitting s Extra Thick 304 -Series Stainless Steel (42% Thicker than most major Brands) Dales are Machine Drilled and not punched. (Punched hales can cause a loud whistle) Rated BTU Input:. Up to 125,000 (ISG) 10 Year Warranty (Twice as lona as other major Brands) As for the fire pit, there is no specs as it is created by Kona Contractors not a kit purchased. It is a custom steel welded frame faced with with cement board. We then apply a cultured stone veneer and caps (usually form Sunset stone in Castle Rock). I have attached the specs here for general stone application. We use the following Q `3 z INSPECTION R INSPECTION REQUEST I IKI:P' . (303) 234 Inspections will not be performed unless this card is posted on troject site. Call the inspection request line before 11:59 p.m. to receive an inspection the followin¢ Ocggpgnc� y/T�e Inspector Must Sign ALL Spaces pertinent to this project vvV 4uy Foundation InspectionsDate Inspector Pier Initials Comments Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prio Tr o Underground/Slab Inspections Dat Inspector Electrical Initials Sewer Service Plumbing Do Not over Un Rough Inspections Wall Sheathing Mid -Roof -- Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building V roval Of The Above d or Below/In-Slab Work Prior To Date Inspector Initials Date Inspector Comments ons oval Of The Above Inspections Comments Initials Comments Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. NOTE: All items must becompleted and a Of Occupancy is issued. A approved by Planning, Pub/ic Works, Fire and Building before a Certificate Approval of the Final Building inspection does not constitute authorization of occupancy. =or low voltage 9 permits —Please be sure that rough inspections are completed from the Fire District and electric ''ow v ✓ the Building Division. 'For Inspection Time Window —Please email insptimerequest@ci.wheatrid e. voltage th the property address in the subject line of the email. Time window is base , g us by 8:00 A.M the morning of the inspection Occupancy Is Not Permitted Until A Certificate of Occupancy IS Issued Protect This Card From The Weather cs) 7 � - ll�,/ INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Occupancy/Type inspections wui nOT De periormea unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pnur Cnncrafa Prinr Tn Annrnval t1f Thn Ahnan L,anmm +;., Underground/Slab Inspections Date Inspector Comments Initials Electrical - - ---- - ---- -- ---- -------- Comments Sewer Service Plumbing uv Noll: .over unaerarouna or tseiownn-'lan work Prinr 1 n Annrnval of Tho Ahnac Incnnr4innc Rough Inspections Date Inspector Initials - - ---- - ---- -- ---- -------- Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. WV VW 0!JV NUilli La - FIcdZOc LAG auie 111dl ruuyii 1115Pecucns are compietea rrom the rare district and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Res. Accessory Struc PERMIT - 201700377 PERMIT NO: 201700377 ISSUED: 04/28/2017 JOB ADDRESS: 11871 W 39th PL EXPIRES: 04/28/2018 JOB DESCRIPTION: Construct a pergola attached to the rear of the house; will cover existing patio space - 140 sq ft **REVISION** Add hot tub to be located on new patio space; size = 7 ft 4 in x 6 ft x 8 in; Energy efficient 160w/hr. Hot tub will be installed on 6 in of roadbase. 35 LF; 76 sq ft; 50 amps; 349 gallons (**HOT TUB PERMIT PULLED SEPARATELY) **REVISION 2** Hot tub permit pulled separate Permit No. 201700550 *** CONTACTS *** OWNER (303)421-1484 MAGNUSON CHERI GC (303)766-8732 Justin T. Lambrecht 170101 5280 Outdoor Designs LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,000.00 FEES Total Valuation 0.00 Plan Review Fee 81.28 Use Tax 90.00 Permit Fee 125.05 �`�' V� ** TOTAL ** 296.33 '�a *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. City of Wheat Ridge Res. Accessory Struc PERMIT - 201700377 PERMIT NO: 201700377 ISSUED: 04/28/2017 JOB ADDRESS: 11871 W 39th PL EXPIRES: 04/28/2018 JOB DESCRIPTION: Construct a pergola attached to the rear of the house; will cover existing patio space - 140 sq ft **REVISION** Add hot tub to be located on new patio space; size = 7 ft 4 in x 6 ft x 8 in; Energy efficient 160w/hr. Hot tub will be installed on 6 in of roadbase. 35 LF; 76 sq ft; 50 amps; 349 gallons (**HOT TUB PERMIT PULLED SEPARATELY) **REVISION 2** Hot tub permit pulled separate Permit No. 201700550 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applica le building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be pert/ormed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new pen -nit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division, 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. k i--ftAIJIm , R FOR OFFICE USE ONLY City of Date: ) i �W heat id e I /q/ � 1 MUNITY DEVELOPMENT —w Plan/Permit# 003 Building & Inspection Services Division 7500 W. 29`h Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits -.cimheatridge.co.us Building Permit Application *"* Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. " Property Address: 11871 )E. 39th Place Wheat Ridge, CO 80033 Property Owner (please print): Cheri Magnuson and Pete Sarnataro Phone: 720.837.3498 Property Owner Email: PSarnataro@changehealthcare.com, cherimagnuson@gmail.com Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: MK Structural Engineering Architect/Engineer E-mail: mike@mkstructural.com Phone: 321.600.0672 Contractor:-14-��e Contractors City License #: 1-1 b 10 1 Phone: (5c,_3) _7uu - t 7 3` Contractor E-mail Address: --w%2seq � Zeooj4da,! J"Os CokvL Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form m W 1U ID W 2 4) C+ 2 V IN E:a cai lu W ' y • 'a! ..:Y. � ii is > z Ll L Z a 49 z x z F H � L to i � a .ate il _ iz � � z Ll L Z a 49 C% F H � L to C � a .ate .?► �. M D (LI � � t0 � Q to m to C1 () z Ll L Z a 49 0 COMMERCIAL 0 RESIDENTIAL QesgLjoion of wQrk. (Check all that apply) C1 NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck. etc.) MECHANICAL SYSTEMIAPPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEMIAPPLIANCE REPAIR or REPLACEMENT OTHER (Describe) (For ALL projects, please provide a gggilIgg description to be performed, including current use of areas, proposed uses, square footage, existing Condition WldpffLQ'�t-, new conditior aooliance Size and efficiency, type and aniount of materials to be used, etc) We are proposing to construct a pergola attached to the rear of the house. It will cover a new patio space. Currently the area is grass. Sq. FULF 140 Btu's Amps Squares Gallons Project Value: (Contract value or the cost of ilLmatenals and labor included in the qjIUM project) $ 6.000 1 0"'NFR/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hcrchy certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, casements or restrictions of record, that all measurements shown and altegations made err accurate: that I have read and agree it) abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City ol'Wheat Ridge codes and ordinances for work under any permit issued based an this application. that I airn the legal o%ret or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal ov4m of any entity included on this application to list that eritiry on this application, CIRCLE ONT WWA`ER) WO.VTRACTOR) pr (AUTHORIZEDR, RE�VTATIVEJ of (014WER) (C0.VTR,4CT0R) I i ,�A PRINT %4W RL, ZONING CG WUMENTS Revlewer BUILDING DEPARTMENT COMMENTS Reviewet PUBLIC WORKS COUMENTS Revievver PBOOF OF §MIMN EQM Fire Department 0 Recei,*d C1 rat Requiled water District 0 Ret eweo 0 Not Required Sanitation District C] Received (3 W Reawred DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION SPRINKLERED OCCUPANT LOAD IBuilding Division Valuation: $ 1 City of _/' Wheat ' idge C,OMMUMTY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permits(c-)ci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: AnA er•°.aol 1003 r7 Plan Review Fee: t 10 3, 0 3 Building Permit Application i A *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 11871 39th Place Wheat Ridge, CO 80033 Property Owner (please print): Cheri Magnuson and Pete Sarnataro Phone: 720.837.3498 Property Owner Email: PSarnataro@changehealthcare.com, cherimagnuson@gmail.com Mailing Address: (if different than property address) Address: 4320 Kipling St. City, State, Zip: Wheat Ridge, CO 80033 Architect/Engineer: Architect/Engineer E-mail: Contractor: K & D Landscape Contractors City License #: Phone: Phone: 303.425.8963 Contractor E-mail Address: trish@outdoorlifestyles.co, kdlandscape@msn.com Sub Contractors: Electrical: Dave Jones- Prospect Electric Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Mark Remy Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL tR RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT 2 OTHER (Describe) Hot Tub (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) We are proposing to install a Bullfrog hot tub that is 7'-4" x 6'-8" on a new patio space. It is energy efficient in that it uses approximately 160 watts/ hour. We are going to install the hot tub on on a minimum of 6" of roadbase. Currenity there is grass in this area and is not used by the homeowners. Sq. FULF 35 LF/ 76 SF Btu's Amps Squares Gallons 349 Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) 10,000 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Signature (first and last name): PETER SARNATARO DATE: 3.14.2017 7 � ZONING COMMMENTS: 17>7. Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ Swimming Pools, Spas and Hot Tubs Checklist Complete The Information Below That Applies to Your Project: Locotkm ti Pool XlivtTub or a "muni WOuUkmrs WAbom Ground f On -Ground U Within A ire Pool Dema Pool D nvensiaosj5iae (sf, diameter, etc.): Type of Pool W gam, fiberglss, rrrrrtrl, etc 1: El Unheated a"emmi. Type of EQ; El DWITon: aaecbic or aNatonii Gm apaneGas: EEWsting Tack or a New Tank Yes VIA required 5ubmittsb 1. a swin"M Pool Appkrabon for Construction aid this 2. a -ate plan, pool location and distance to scructmes, prarWnV fines, +mil, saw occupancy classification of ALL buAdvW on Lorcelithawse e 3. II pool barier shown on site plat - fences, yams/doom Inwhade direction of swore, wkdow^s, Wentz, Wei, etc, as appficable in Appease G. 4. Cr a Poodphiin, critical area strewn eW4 must be shown on site 5. Q a Electrical tine -Lire drawings if new electrics f is being 6. a a Appendix £s', Section Afa105 Savvier Requirevei is — 4 Doom with direct access to the pool through that wal shat be equipped with an Warm why pnoduces an aaxgak warning when the door and/or its screen, if present, we opened. The atarm shat be meted and hrbcbd in accor+dafce with UL 2017.7he deactivation ) sha/ be lid at least 54 inches 11372 mm) above the threshold of the door_ Accuracy of the submittal package, incluilling this checklist, is the responsibility of the applicant. JON LEDUC 1 f 3.22.2017 saw. Colorado Driver License �s 02-144-0733 Expires: 11-21-2018 �•:. cuss: R : 09-23.2013 x End: ws: 11-21-1 A Rest: Previous Type: fit 6102° WI: 220 Eyes: vow: 9/9/13 Colorado Chapter of the International Code Council Noun to Use this Guide Provide two sets of plans, drawn to scale and complete the following (hint: use graph paper with 114" squares. Example: 1/4" =1'): Check with your jurisdiction for additional requirements. 1 Complete this Building Guide by filling in the blanks on page two, and indicating which construction details will be used. 2 Provide 2 Plot Plans (site plan) showing dimensions of your project or addition and its relationship to existing buildings or structures on the property and the distance to existing property lines drawn to scale. See Page 2 S R11 out a building permit applicaflon. The majority of permit applications are processed with little delay. The submitted documents will help determine if the project is in compliance with building safety codes, zoning ordinances and other applicable laws. The Colorado Chapter of the International Code Council is a professional organization seeking to promote the public health, safety and welfare to building construction. We appreciate your feedback and suggestions. To obtain a master copy of this building guide, please write to the Colorado Chapter of the International Code Council, P.O. Box 961, Arvada, CO 80001. http://www.coloradochaptericc.org This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. City Of heat Ric/ge 8trild/n9 Div;,.: Ill 9/9/13 DINIGUOU 871 E. 39th Place Wheat Ridge, CO 80033 i. Fill in the blanks with dimensions and materials which will be used to build the structure. Please print legibly. 2. Indicate in the check boxes which details from page 4 will be used. Please note if any of the sides of your carport addition are closer than 5'-0" to the property line, that side of the carport must be enclosed with a solid 1 hour fire rated wall as shown in Alternate Details B and C. You must however, keep at least two sides of the carport open to conform to the building code requirements. Zoning approval is required. 8. Roofing to be installed per manufacturer's instructions, including low slope application and required inspections made. Roof covering N/A I Underlayment N/A /example: Clens A 3 tab shingles) I exam : 10 ran NE 19 W Size and Amount of Lags Sheathing examp exre/o,p (38) 1/2" SS LAG @ 12" OC (example: Two Wx 4 112 -lags @ 16 -OC) 12 pitch I 2x8 rafters spaced 12 " O.C. (example: 2x 8 rapers spaced W O.C) Patio Note: Walls, posts, and overhangs closer than 5' to the .............Overhang property line to be 1 hr. rated No closer than 2 feet to property line Beam splices to occur over Detail A Detail 8 posts with 1 1/2" bearing '•. 0 O . 0 Alternate A 0 Alternate 8 0 Other (provide detail) (see Pao 4) t 3J x 8 n beam Existing (see page 4) (example: (2)2x10') building San Span 8' Maximum rise 7 (example: 120) 3/4" at top of door ❑ Detail C threshold 0 Alternate C ( page 4) 6'-8" Siding Isolate from Slab minimum (for Memae8ow Slope 6 m'x 6 ��pOStS .. (example: 47x41 Concrete Slab T-011 (example: 5' apart (example: 67 minimum Minimum Diameter Pier 8" -`r . ; i, i, (size determined by load) Footing X (for Alfemate C aiN) This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. FLOOR PLAN PRESSURE TREATED RAFTER AT 12" OL. MAX (SEE RAFTER SIZE CHART) 2"4" PT. NO. I SYP. WOOD SLAT ATTACHED TO RAFTER WITH (1) 3" DECK SCREWS AT EACH RAT=TER (SLATS AT 6" O.C. MAX) N 2"x8" P`T% NO. I SYP. WOOD BEAM ATTACHED TO POST WITH (2) }"0 STAINLESS STEEL MACHINE BOLTS WITH NUT AND WAST -BR 6"xb" P.T. WOOD BEARING POST APPROXIMATE GRADE 12"0x.AV CONCRETE FOOTER 4" BED OF GRAVEL NOTE: OPTIONAL ROUGH SAWN CEDAR IN LIEU OF PT. NO- 1SYP- 2'x8" PT. NO. 1 SYP WOOD BEAM (TYPICAL WHERE SHOWN) .1 1 6'x6' PT. WOOD POST (TYPICAL 'A" FASTEN RAFTER TO LEDGER WITH 114" \ S.S. LAG SCREW O PTI 2")8° FT. NO. 1 SYP WOOD RAFTER LEDCiER 2"x&" PT. NO. l SYP W OC> RAFTER AT 12" OL. MAX (TYPICAL WHERE SHOWN) NOTE: S" 2"x8' PT. OPTIONAL - RAFTER ROUGH SAWN ;p CEDAR IN LIEU OF PT. NO. 1 SYP. -- 1° TYP RAFTER END DETAIL suW DESIGN CRITERIA MASONRY L D -I CODES: - FLORIDA BUILDING CODE 2014 WOOD WALL bxbPT NQ 1 5th EDITS ASCE/SEI 1 -lo 'MNiMU M DESIGN SYP OR ROU314 LOADS FOR BUILDINGS AND OTHER -s SAW CEDAR STRUCTURES" SIhiPSON ABE66 FOR D-2 6x6 FM NO.) SYP SIMPSON ABA66R FOR ROUGH 5AW CEDAR �° EXPANSION OR EPDXY ANCI-IOY� EMBED 3" MIN. DESIGN WIND SPEED: YLit c 160 MPH (3 SECOND GUST) PER FIGURE 1609A Veed " 124 MPH PER SECTION 16093.1 RISK CATEGORY I ( PER TABLE 16045) SURFACE ROUG+IESS: C PER SECTION j 1609.4 WIND EXPOSURE CATEGORY. C PER SECTION 1609.4 MEAN ROOF HEIGHT: 8 FT ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT, GCpt = ./- ozo 1 ,-EXISTMG 4' CONCRETE AULDINGSo SLAB (MIN) A. . SUILDING IS ASSUMED TO BE OPEN AS DEFINED BY SECTION 62 ASCE 1-10. AL BASE DETAIL •-rr `-m 2'x8" PT. No.] SYP. 0 WOOD EXISTING MASONRY WALL WITH (2) %"0 GALVANIZED EXPANSION ANCHORS WITH NUT AND WASHER (4' EMBED) OR WOOD WALL WITH ►y" SS. LAG SCREWS o v TYR PERGOLA SECTION swrw-T : ' z o, 171 E Of Wheat CO~1NITY DEVELOPMENT R.:'PROVED Nevif.-ed for Code Compliance J ItA,,_ Plans Examiner 0 om VAOMRv of otrmi[ rhe msuonce Of* permit Or CAWOVat of pians $PVCOC m ondcomputotlom shop not be a permit Jo , or an appowlo1 ant• vAp om Eo on y of the pmwsiom of the Ndang code of of any City ordvipnee,, hmmb presuming to give authority to violateOICancetthe provislam of (he BWldkV codes or other ordumnces of the City O M4 W bt VW d. ")%/a City of ; W heat Rjdpe COMMUNITY DEVELOPMENT APPROVED Rc� ve(i fcir Code Compliance `\ 1 � _ 1 / Mans Ewmfner I�7 VA tr of arMit: The issoaroe Of* P~ Of asitovolttfplotts tpa�kaliru oedcomputotiom shop not be o Pem*1 , r at apWA'dol Mp vloleflaoro ony of the provisions of the 6o11dinp code Of of a+y City osdkWBM. Proofs presuming to give cvthorlty to violate ofeanalthe PMVW to ofthe pvitdhp rales a othe, ordmonces of the City shop not be vufid. Existing roof rafters or trusses 4Galvanized metal joist or rafter hangers Extend undedayment from p new roof a minimum of 18" onto existing roof '�— Remove existing fascia Cont. 2x ledger Secure ledger to wall with lag screws @ 16" O.C. Locate lag screws to penetrate top plate or studs Note: Remove brick veneer at top of wall inq wall before installing continuous 2x ledger 9/9/13 Lap underlayment a minimum of 18" under existing roofing felts Solid 2x blocking on 2x12 or greater �---- Roof be downs required Existing wall Existing Roof (remove existing Cont. 2x6 secured to existing roof with fasteners at each rafter or truss Solid 2x blo idng on 2x12 or greater Solid 2x fire blocldng on 2x12 or greater Roof tie downs required Roof tie downs required 5/8" type "X" exterior gypsum sheathing Galvanized metal Galvanized metal post/beam connector Treated or decay resistive post Minimum 3 1/2" Galvanized Galvanized concrete slab 1" b > " column base t w/ 1" spacer to from Slab concrete .� Check local penetration Isolate from Slab 3'-0" department for " minimum Anchor bolt caissons may be required. Footing 7" minimum 8" penetration minimum 3.011 diameter minimum concrete caisson i 8„ This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 2x facia post/beam connector No closer than 2 feet to property line Exterior siding Two If of 5/8" type "X" Infill between posts exterior gypsum board soffit w/ 20's @ 16" O.C. Less than 5' to property line Bottom plate shall Infill between posts be treated wood w/ W's ® 16" O.C. Minimum 3 1/2" 1„ concrete stab Galvanized column base w/ 1" b > " spacer to concrete t Isolate from Slab Anchor boft 7" minimum Check local penetration building 3'-0" department for " minimum swelling soils. caissons may be required. Footing i CITY OF WHEAT RIDGE Building Inspection Division p (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:' Job Address: Permit Number: ❑ No one available for inspection: Time / AM/,PM Re -Inspection required: Yes o When cor ectmns have been made, call for re -inspection at 303-234-5933 j - -----� Dater Inspec_- tor: DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE Building Inspection Division t (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: t -7 / 3 - / Permit Number: D O/ 7 G o _. 7K Q 44 ❑ No one available for inspection: Time SAM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date:- 1)Inspector: DO NOT REMOVE THIS NOTICE 1 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 1 Job Address: -311 / Permit Number: D d 1 7 d b 3-7 7 ❑ No one available for inspection: Time �'S � AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: r DO NOT REMOVE THIS NOTICE City of Wheat Ridge � r j� Residential Roofing PERMIT - 201705524 PERMIT NO: 201705524 ISSUED: 08/05/2017 JOB ADDRESS: 11871 W 39th PL EXPIRES: 08/05/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning asphalt shingles with 41 sq. *** CONTACTS *** OWNER (720)837-3498 SARNATARO PETER SUB (303)981-1265 Jon Lowrie 100243 Monarch Construction & Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,200.00 FEES Total Valuation 0.00 Use Tax 277.20 Permit Fee 267.70 ** TOTAL ** 544.90 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. ,�► 41 City of Wheat Ridge Residential Roofing PERMIT - 201705524 PERMIT NO: 201705524 ISSUED: 08/05/2017 JOB ADDRESS: 11871 W 39th PL EXPIRES: 08/05/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning asphalt shingles with 41 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po Flans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable�or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Q Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz 1061_0 J ::) From: no-reply@ci.wheatridge.co.us Sent: Monday, July 31, 2017 2:49 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Danny Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process y varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 11871 w 39th pl peter sarnataro 7208373498 Field not completed. Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. Attached Copy of Field not completed. Contract CONTRACTOR INFORMATION Contractor Business monarch construction Name Contractor's License 100243 Number (for the City of Wheat Ridge) Contractor Phone 3039811265 Number Contractor Email Address permits@monarchroofs.com Retype Contractor Email permits@monarchroofs.com Address DESCRIPTION OF WORK Are you re -decking the No roof? Description of Roofing owens corning Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 41 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES 41 (pitched + flat) of all z roofing material for this proj ect Provide additional detail house here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract < 3200 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant brie lowrie Email not displaying correctly? View it in your browser. 3 uWW, apAR ", 40 04tc-ar fV Andram 9/< /-�- Phone A� zz Ton 1% of roofing contractor A L cirvt if lbo 0 cow - -�i 04 Y -- polo Mq gqgp #I am Q 1 on Mim a W"V lk4w",O So& WO toy 4vaup i! Q 04k §Wums a No 1 $4 man 4 My W - : 11 -'A"IV. 4$;-; ?�' had 1, W, 0 1 �!(,40- aw lnsqr4ftce W-Moarly dowfinist" L, A, N- cow,0414 I fa (4, Awojok* 03W of Swipe; 'It t. c4oauv CW� te" -4 4VY 4419 Iowa Ot wago MAW pIMOY5, irwr4ima Xif,' ww,4,�f Moti v �y ji4 opo pow, Wo WAMP COW of umm iIrw W Tow onto dw, i I W two NMI 00 'P, WO, g-:4 WA WN Ram Who MMq MW %v MWPOW wMany G.-!-! (Cnky, 01 ohs u"up"Awn I# will P:v So j! vshmu"R no am Awl Sir; M bw i%Liqil(h funck, I uEa PA4SNO Got w v G" M 16 Pr !N4 �,nO cirvt if lbo 0 cow - -�i 04 Y -- polo Mq gqgp #I am Q 1 on Mim a W"V lk4w",O So& WO toy 4vaup i! Q 04k §Wums a No 1 $4 man 4 My W - : 11 -'A"IV. 4$;-; ?�' had 1, W, 0 1 �!(,40- aw lnsqr4ftce W-Moarly dowfinist" L, A, N- cow,0414 I fa (4, Awojok* 03W of Swipe; 'It t. c4oauv CW� te" -4 4VY 4419 Iowa Ot wago MAW pIMOY5, irwr4ima Xif,' ww,4,�f Moti v �y ji4 opo pow, Wo WAMP COW of umm iIrw W Tow onto dw, i I V -I, , -"' - —V�- .0 WAYA-vufflms allom, terve mail the back of contract 23 5 -year workmanslilp warranty on Wfing, alt other cor;1ructipa jr,jes will receive a I yr. workmanship warranty In — qtr ended Warranty Per Sq, $__ Chcle: Omits Corning Platinum GAF Other. march Constfuction & Roofing will Provide general liability insurance coverage of $2,000,000 general agg eg V- orm magnetic sweep of driveway and yard for removal of any nails r ate Move all and trash debris from work listed ash and — Replace Gutter Screens Type: — Insurance funds inClUde Wbrjga9-0—co�'—Par za special Instructlions tion form) Tne approximata cost of the services pfted on damages known at Ole *110 4"is Cor"nia is entereo I.- -7Y insum"Ca, kWaO will part= the scope of " a $ I delermitried by ppr 74�0- - oved by rf, & te %MS Pri'--d low, not iqd4de , d of items newo to DM'R t"'rl:y/couti�j ream Initial 1"t lnsorapcet� payincl out Ulp*roaatal daims bilV4 by +' nary Nt are X.PrOved Uy the in4uraq�a j;am wly foraddiv nal o, cod". WeAch may in inuroloe oompany Wnarqn 41 ftPt*'-'T"0 rric(Aases 0 wsts become a W of tm oanthgot the q'q8l'VAix- aric price M , rw on bo�tukri the ln� inautance- apprvmd soW. Cw -W,31140 CIRWany and MWarch sholl bAcorre N10 firlel PriGe for u!e Wmer vAq 64 reeponsiblo to PY for at)y U ra na"-wovero'ble 44prDeation 0V a the insuiance cowany detenydri PQ do Ad t's-0-P, 3vered Woln the 664fM of cOVelaos provided by your irgurenc 01I y' itionat Mrk 4U(4DdXA by tura customr thAr ApproxireqU Uat 61 -ti Iftess d payfftnt qpl4x% 9-W -af w*'4 x� -444"Ap 10 ��A'A in insuraZ�J Val"fsy dokl" - -0 404! 0 ilao(fai ops"- -Y" tion to 048tomer W 00W terito -poi-I'l qf Mooprol M Aive dates. rd Matic.q., If the proo-4q dwIvrplons to use DfV"ft'Q's' of pfq,-e *0�*n V#.-rebo' of P n*'Qe 10 P�f-4A v IK i'7';' 40 f�4 arty Insufam4 0�6)0 id f(W40 hwe'4 03to."ZI the 4tisufanoo coinpany 4 litki hodidal* %4 qk��UOQ afte� today *646 inooteo a -ova R Wititq Li. C a� I�-pqjoe 'e! to ft of J rhimW raferefw4a; �q p "Wd h"r-Wch C(Ir4ojimop fn0jprify of 1,,I@ t,,,prlrq Worj,. on to prope,,+t alt . 9"C"Alg rW k'4 60 (we) NrtR: by S19AIn7 Wow to ail the v-, of --tliiz oir.o.. Late it AC . 5t* IRM i CITY OF WHEAT RIDGE 9�(303) Building Inspection Division _:�(303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: .2r -)r 0 S ❑ No one available for inspection: Time ' �� ! '> AM/PM Re -Inspection required: Yes_ -No When corrections have been made, call for re -inspection at 303 -234 - Date:— .7 1,`17 Inspector: a DO NOT REMOVE THIS NOTICE r, i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: P', t Job Address: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: - ? Inspector: i DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: E I C"C Job Address: u X7 I j A ) �q �i ISL Permit Number: 2.�L n 6b ❑ No one available for inspection: Time AM/ M Re -inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Date: 1 �~i Inspector: )c SLQ ���,r DO NOT REMOVE THIS NOTICE City of Wheat Ridge Res. Accessory Struc PERMIT - 201700377 PERMIT NO: 201700377 ISSUED: 04/28/2017 JOB ADDRESS: 11871 W 39th PL EXPIRES: 04/28/2018 JOB DESCRIPTION: Construct a pergola attached to the rear of the house; will cover existing patio space - 140 sq ft **REVISION** Add hot tub to be located on new patio space; size = 7 ft 4 in x 6 ft x 8 in; Energy efficient 160w/hr. Hot tub will be installed on 6 in of roadbase. 35 LF; 76 sq ft; 50 amps; 349 gallons (**HOT TUB PERMIT PULLED SEPARATELY) **REVISION 2** Hot tub permit pulled separate Permit No. 201700550 *** CONTACTS *** OWNER (303)421-1484 MAGNUSON CHERI GC (303)766-8732 Justin T. Lambrecht 170101 5280 Outdoor Designs LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,000.00 FEES Total Valuation 0.00 Plan Review Fee 81.28 Use Tax 90.00 Permit Fee* 125.05 TOTAL 296.33 � J' '�T U *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. City of Wheat Ridge Res. Accessory Struc PERMIT - 201700377 PERMIT NO: 201700377 ISSUED: 04/28/2017 JOB ADDRESS: 11871 W 39th PL EXPIRES: 04/28/2018 JOB DESCRIPTION: Construct a pergola attached to the rear of the house; will cover existing patio space - 140 sq ft **REVISION** Add hot tub to be located on new patio space; size = 7 ft 4 in x 6 ft x 8 in; Energy efficient 160w/hr. Hot tub will be installed on 6 in of roadbase. 35 LF; 76 sq ft; 50 amps; 349 gallons (**HOT TUB PERMIT PULLED SEPARATELY) **REVISION 2** Hot tub permit pulled separate Permit No. 201700550 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. 09%28%7 Signature of OWNEk or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division, 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of W he at j(Age COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits ci.wheatrid e.co.us FOR OFFICE USE ONLY Date: f l/(DllI Plan/Permit # a0l�003�1 Plan Review Fee: 7b ilJ� I Building Permit Application ►�, , Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 11871 )(,. 39th Place Wheat Ridge, CO 80033 Property Owner (please print): Cheri Magnuson and Pete Sarnataro Phone: 720.837.3498 Property Owner Email: PSarnataro@changehealthcare.com, cherimagnuson@gmail.com Mailing Address: (if different than property address) Address: City, State, Zip: Arch itectlEngineer: MK Structural Engineering ArchitectlEngineer E-mail: mike@mkstructural.com Phone: 321.600.0672 Contractor: K & ID LO &Gape S72�-O 0_4d r I -LC Contractors City License #: 1-7G i o ( Phone: 4&3-425-8965 (7--3) -7&41' t 7 32 Contractor E-mail Address: _s-%se� Cool L Sub Contractors: Electrical: W. R. City License # Other City Licensed Sub: City License # Plumbing: W. R. City License # Other City Licensed Sub: City License # Mechanical: W. R. City License # Complete all information on BOTH sides of this form 3 W -, e m to e 4) 2 J U o 4L ,n Q0 f 0 W G Jv 2 a J ` � A� a \ E g g !, RL o ; C -' ,E LU2 Q • L !. f a' , , OaC a c ; 41 ;mo�� CM in f , :.w �W: , l Sw LL ; Ei g � , CL CLC to cs ; r��m �E�� ; E E 0 m ° x $ m ; 1 m40 if Q' i W r IX 0 2 W p Iry f pp 0 OQ 'Or a N m Z W wzb 4 erew s uc cc 0"o ,^ Q�'vpYMsVVOVV`P^ 93w- Sw LL ; Ei g � , CL CLC to cs ; r��m �E�� ; E E 0 m ° x $ m ; 1 m40 if Q' i W r e U oM tu y © e r IM G 'D 0 2 � � C r H j � a G 43 s e U oM tu y © e r IM G 'D IIZ L,J 1.1 � � C r H j � a G 43 s v' CD c d QD 0 IIZ L,J 1.1 0 COMMERCIAL 9 RESIDENTIAL Description of work. (Check all that apply) NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEWAPPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) tFor ALL projects, please provide a #Ag1W description of work to be performed, including current use of areas, proposed uses. square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to ut etc) We are proposing to construct a pergola attached to the rear of the house. It will cover a new patio space. Currently the area is grass. Sq. FtJLF 140 Amps Btu's Gallons Squares I Project Value: (Contract value or the cost ofilLmatenals and labor included in the 2nft project) /I S ) ON) I O%k'Nt.'R/CONTRACT0R SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and dca not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Whet Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. t7RCI E OVF (OWAER) WO.VTRACTOR) 2r (AUTHOR/27E0 RE ',11174TIVEI0 f (OW"V", (C0.1VTR4CT0R) PRINT NA%1E.-:jJ D.4y, ZONING COMMM61NIM Reviewer e-IJILDING DEPARTMENT COMMENTS Reviewer PUBLIC WORKS COMMENTS Reviewer A ,, FQF §VINJUM EQM§ ;:ire Departnent [I Received El WRoq,.,,d Water District 0 Recewoo Not RequoW Sanitation Dmtoct [] Recoved Not Required DEPARTMENT USE ONLY OCCUPANCY CLASS IFICATIDN TYPE OF CONSTRUCTION SPRINKLERED C)CC UPANT LOAD Building Division Valuation: $ I City of W heat Ridge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits@ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Ian/Permit # Plan Review Fee: t 10 ao J Building Permit Application i # I A�.l; *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 11871 t! 39th Place Wheat Ridge, CO 80033 Property Owner (please print): Cheri Magnuson and Pete Sarnataro Phone: 720.837.3498 Property Owner Email: PSarnataro@changehealthcare.com, cherimagnuson@gmail.com Mailing Address: (if different than property address) Address: 4320 Kipling St. City, State, Zip: Wheat Ridge, CO 80033 Architect/Engineer: Architect/Engineer E-mail: Contractor: K & D Landscape Contractors City License #: Phone: Phone: 303.425.8963 Contractor E-mail Address: trish@outdoorlifestyles.co, kdlandscape@msn.com Sub Contractors: Electrical: Dave Jones- Prospect Electric Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Mark Remy Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL 2 RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT MOTHER (Describe) Hot Tub (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. FULF Amps We are proposing to install a Bullfrog hot tub that is 7'-4" x 6'-8" on a new patio space. It is energy efficient in that it uses approximately 160 watts/ hour. We are going to install the hot tub on on a minimum of 6" of roadbase. Currenity there is grass in this area and is not used by the homeowners. 35 LF/ 76 SF Btu's Squares Gallons 349 Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) 10,000 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Sienature (first and last name): ZONING COMMMENTS:7F Reviewer: `hl' 7 i 11-\ BUILDING DEPARTMENT COMMENTS: Reviewer: PETER SARNATARO DATE: 3.14.2017 DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ Swimming Pools, Spas and Hot Tubs Checklist Complete The Information Below That Applies to Your project: Instountion Location 11,SwjPool, )KHotTub or:%M akyrGrouand .Outdoors 9#Awm Grovad / On4round 0, Wdhin A Stractore swinvWing PGC4 oefta Pool Dirmnsions/Ske Isf, diwneter, etc.): Type of PCOA 1k; ME#& fibervas, V*W, etc* a thilbemed Mewed:- TWe of UX - El UM/Ton: I a, Electric or a tomb" Gn aLigtid pn4wm Cam: - rf - * - - ' or a New TWA 7771 Yes MIA Required SubmAtob 1.1 a I Swnmwq Pool Application for Construction and bNo aved&t 2- a Site plan, poof location and datunce to Vis,propert;# firms, wW occj*w" cbssili AWoft of W AU tsar on pwce, [*; hoosew"w, CM4 3. ]a Pool baa mr Mmm" on site plan nm*WM fenck% ptex/doors favAide direction of svnyW, vekW�nn, &Wm, i"Im, etc. as appficable in Appem% CL 4. a 11Ploodohin cruet area (pond, strearia' etc.1 rnmt be shown on site plan. 5. a a 6;i;z7W One -Line dnwinp if new electricW is being instoged. C 11 a Appendix G; Section AGIDS Sarvier Requirenmenu - 92IDoors with direct mmess to the pond through that wad shaM be eqtupped with an abirm vdvk% prodaKes an mmfibie vionving when the door wWfor its screen, if present, we opened. The Mmo sW be fined and Wkiled in accordance with UL 2017. The deactimtkia 3wtd**) strA be Wcated at bmt S4 inches t1372 mm) nbmm the threshold of the door. Accuracy of the submittal package, including this checidist is the responsibility of the applicant. JON LEDUC \V 1 3.22.2017 9/9/13 Colorado Chapter of the International Code Council Nora to Use this Guide Provide two sets of plans, drawn to scale and complete the following (hint: use graph paper with 1/4" squares. Example: 1/4" = 1'): Check with your jurisdiction for additional requirements. 1 Complete this Building Guide by filling in the blanks on page two, and indicating which construction details will be used. 2 Provide 2 Plot Plans (site plan) showing dimensions of your project or addition and its relationship to existing buildings or structures on the property and the distance to existing property lines drawn to scale. See Page 2 S Fill out a building permit application. The majority of permit applications are processed with little delay. The submitted documents will help determine if the project is in compliance with building safety codes, zoning ordinances and other applicable laws. The Colorado Chapter of the International Code Council is a professional organization seeking to promote the public health, safety and welfare to building construction. we appreciate your feedback and suggestions. To obtain a master copy of this building guide, please write to the Colorado Chapter of the International Code Council, P.O. Box 961, Arvada, CO 80001. http://www.coloradochaptericc.org This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. City or W hear Ridge Quildin9 D1,,._. Ill 9/9/13 871 E. 39th Place Wheat Ridge, CO 80033 1. Fill in the blanks with dimensions and materials which will be used to build the structure. Please print legibly. 2. Indicate in the check boxes which details from page 4 will be used. Please note if any of the sides of your carport addition are closer than 5'-0" to the property line, that side of the carport must be enclosed with a solid 1 hour fire rated wall as shown in Alternate Details B and C. You must however, keep at least two sides of the carport open to conform to the building code requirements. Zoning approval is required. $. Roofing to be installed per manufacturer's instructions, including low slope application and required inspections made. Roof covering N/A Underlayment N/A (example: Class A 3 tab shingles) exam 1 Size and Amount of Lags SheathingN/A (38) 1/2" SS LAG @ 12" OC —%x eWpywoo (example: Two 1/1'x 4 W tags @ 16"0.C.) 12 pitch I __l_o/, 2x 8 rafters spaced 12 " O.C. (example: 2 x 8 rafters spaced 24" O.C.) Patio Section Note: Wails, posts, and overhangs closer than 5' to the •'"" Overhang / property line to be 1hr. rated •• •••••• No closer than 2 feet • to property line Beam splices to occur over posts with 1 1/2" bearing U Detail A U Detail B ... U Alternate A U Alternate B`, 2 It n U Other (provide detail) (sae page 4) L� 1 X 8 beam Existing (seepage 4) (example., 25x10") building San Span 8' Maximum rise 7 (example: 12'0) 3/4" at top of door 0 Detail C threshold U Alternate C (see page 4) 6'-811 Siding Isolate from Slab minimum (brAnemateeonly) Slope •': 6 71 : "x s "posts (example: 4x4*) Concrete Slab spaced 15' apart , 3 -0„ (example: 69 'r minimum Minimum Diameter Pier 8'Footin (size determined by load) g X •' - - _'' (for Alternate C only) This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. it is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 2"AS' I -T. NO. 1 SYP WOOD BEAM (TYPICAL UPERE SHOUN) .l 1 6°x6° PT. WOOD POST (TYPICAL 1 uGu FLOOR PLAN sooie v�+-r—c PRESSURE TREATED -4t RAFTER AT 12" O.C. MAX o1> (SEE RAFTER SIZE CHART) f1"" Q Q FASTEN RAFTER TO 2"x2" PT. NO. I SYp. WOOD LEDGER WITH 1/4° SLAT ATTACHED TO SS. LAG SCREW RAFTER WITH (1) 3" DECK SCREWS AT EACH RAFTER O PTI (SLATS AT 6" O.C. MAX) 2"x8" PT. NO. I SYP. WOOD BEAM ATTACHED TO POST WIT}+ (2) }°O STAINLESS STEEL MACHINE BOLTS WITH NUT AND WASHER 6"x6" pT_ WOOD BEARING POST APPROXIMATE GRADE 12°0y.b-D CONCRETE FOOTER 4- BED OF GRAVEL NOTE: OPTIONAL ROUGH SALIN CEDAR IN LIEU OF PT. NO. I SYP. 2"x8° PT. NO. 1 SYP UIOOD RAFTER LEDGER 2'x8" PT. NO. I SY' WOW RAFTER AT 12" O.C. MAX (TYPICAL WHERE SHOWN) MA5ONRY OR WOOD WALL 6x6 PT NO. I SYP OR ROUGH -s SAW CEDAR SIMPSON A5E66 FOR 6x6 PT. NO. I SYP SIMPSON A5A66R FOR ROUGH SAW CEDAR j° EXPANSION OR /-EPDXY ANCHOR / EMBED 3- MIN. NOTE: 5" 2"x8" PT. OPTIONAL - RAFTER ROUGE} SALIN CEDAR IN LIEU OF PT. NO. I SVP. 4- 1- TYP RAFTER END DETAIL srue r/Y J=0' DESIGN CRITERIA 0-1 CODES: - FLORIDA BUILDING CODE 2014 51th EDITION, ASCE/SEI 1-10-MNRM9M DESIGN LOADS FOR BUILDINOiS AND OTHER STRUCTURES° D-2 DESIGN WIND SPEED: "Vt = 160 MPiN (3 SECOND GUST) PER FIGURE 1609A Yaed a 124 MPH PER SECTION 16093.1 RISK CATEGORY I ( PER TABLE 16045) SUIWACE ROUC44NSSSA . C MR SECTION 1609.4 1L)1hID EXPOSURE CATEGORY= C PER SECTION 16094 MEAN ROOF HEIGHT: 8 FT ENCLOSED BUILDING INTEFNAL PRESSURE COEFFICIENT, GCpf = +/- ODO EXISTING 4- CONCRETE ASSUtMPT1oN8: SLAB (MIN) AL BUILDING IS AS5U'ED TO BE OPEN AS AL SASE DETAIL DEFINED BY SECTION 62 ASCE 1-10. V -MASONRY WALL OR WOOD WALL 9 2"x8- PT. NO. 1 SYp. O WOOD EXISTING MASONRY WALL WITH Q (2) %"m GALVANIZED EXPANSION ANCHORS UATH NUT AND WASHER (4- EMBED) OR WOOD WALL WITH yi" SS. LAG SCREWS r TYP PERGOLA SECTION sure rri �r o Z®Ir 17' O d ME 1 -4t 1 o1> ()A-0 -� Q Q p. :-I -4 _ EA 3 1.6 Ole CRY of COMWheatR dgyp MUNITY DEVELOPMENT IPROWED t eviF wL d for Code Compliance 1 V-') �� l Mans Examinee Daft YA01 or oesrnit The issirorstt o1 a perrsss a approsat ofltorss spetylptlosy and computation, shall not be a perms for, or an approval aj any vbbflors to any of the provisions ofthe buOding code ar oftmy City ordinances. ov.s 4s Presuming to give authority to vbbce of,~ the provisions of the Susdlrp codes or other ordmonces of the City shall nae be solid. ") /'a v►., City of ;W heat w� COMMUNITY DEVELOPMENT APPROVED I;c � veu t r Code Compliance Plans Exaffik r Dke VttlYievotauvrlt: TheissuonoroJ.p~*r*wQvdafpbntspeeykM�yq mrdcomputotiomshoonotneopemgtAw,oroncpph vWvLWWvlabffpsto onv of the provisions of the Eu"ng code or ofary City atdkwm,s. pemW s presuming to give authority to violate of camel the pro kns o/ the &#W4V Codes or other ordinonces of the City Shaff not be valid. Existing roof rafters or trusses Galvanized metal joist or rafter hangers Extend underlayment from ` new roof a minimum of 18" onto existing roof 9/9/13 Lap underlayment a minimum of 18" under existing roofing felts Solid 2x blocking on 2x12 or greater �.---- Roof be downs required 'F`' '- Remove existing fascia Existing Cont. 2x ledger -� wall Secure ledger to wall with lag screws @ 16" C.C. Locate lag screws to penetrate top plate or studs Note: Remove brick veneer at top of wall hq wall before installing continuous 2x ledger Existing Roof (remove existing Cont. 2x6 secured to existing roof with fasteners at each rafter or truss Solid 2x blocking on 2x12 or greater Solid 2x fire blocking on 2x12 or greater Roof tie downs required Roof tie downs required 5/8" type "X" exterior 'y gypsum sheathing Galvanized metal Galvanized metal post/beam connector This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 2x facia post/beam connector No closer than 2 feet to property line Exterior siding Two layers of 5/8" type "X" Infill between posts exterior gypsum board soffit w/ 20s's G 16" O.C. Less than 5' to property line Bottom plate shall Infill between posts be treated wood w/ W's @ 16" 0. C. Minimum 31/2" „ � 1 concrete slab Treated or decay resistive post Minimum 3 1/2" Galvanized concrete slab 1" column base Isolate w/ 1" spacer to :. . ' concrete A, 7" minimum Isolate penetration from Slab Anchor bolt department forminirnum 7" minimum 8" minimum 3'-01f penetration diameter minimum concrete caisson �> This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. 2x facia post/beam connector No closer than 2 feet to property line Exterior siding Two layers of 5/8" type "X" Infill between posts exterior gypsum board soffit w/ 20s's G 16" O.C. Less than 5' to property line Bottom plate shall Infill between posts be treated wood w/ W's @ 16" 0. C. Minimum 31/2" „ � 1 concrete slab Galvanized column base w/ 1" spacer to concrete Isolate from Slab . ' Anchor bolt 7" minimum Check local penetration building 3'-011 department forminirnum swelling soils. caissons may be required. Footing 41 CITY OF WHEAT RIDGE e ! Building Inspection Division j (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: "moi E L- &- Job Address: I l ? !-' P Permit Number: 1 7 lei A- PE ❑ No one available for inspection: Time �?.'-5 � AM/PM Re -Inspection required: Yes ' No *When corrections have been made, call Tor re -inspection at 303-234-5933 La Date: .r Inspector: - �- DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Miscella PERMIT - 201700550 PERMIT NO: 201700550 ISSUED: 04/24/2017 JOB ADDRESS: 11871 W 39th PL EXPIRES: 04/24/2018 JOB DESCRIPTION: Hot tub installation - 6 ft 8 in. x 7 ft 4 in - using hot tub cover; electrical included *** CONTACTS *** OWNER (720)837-3498 SARNATARO PETER *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,000.00 FEES Total Valuation 0.00 Use Tax 180.00 Permit Fee 204.30 ! ** TOTAL ** 384.30 .'� ' C- *** COMMENTS *** *** CONDITIONS *** All work shall comply 2012 International Codes, 2014 NEC (if applicable), and ordinances adopted by the City of Wheat Ridge. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owne of roperty and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I fu er att that I am legally authorized to include all entities named within this document as parties to the work to be performed and`t. t all wo to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services DIv Sion. 6, The issuance or -granting of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any applicable code any ordmanee-T reguI ian f this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST HE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of l6at' `P' ie �COMAAMUNITY DEVELOPMENT Buildings & Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits@ci.wheatridae.co.us FOR OFFICE USE ONLY I Plan/Permit # lC� Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *" Property Address: Owner W 3 �V^' Property Owner Email: 7 E-rC- S te - (,�) (5 MA - 1 , i,.�,.NA-- Mailing Address: (if different than property address) Address: City, State, Zip: 'A Architect/Engineer E-mail: Contractors City License #: 1 -7 0 0 Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Other City Licensed Sub: City License # r�4;) C;:�- Soo 3 j Phone: -72,D, 3 7- j q � 0' Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL X RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT �� OTHER (Describe) LJO i -Tya i A/3 t-c-�Sr� }� w_J EL�c-Tc.( C --A1 (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) 0 , (b—L--;1 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE('(OWNER) (CONTRACTOR) _ (A RIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Signature (first and last name): DATE: t r ZONING COMMMENTS: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of at le CWh6OMMUMTYDEVELOPARENIT-d' City of Wheat Ridge Municipal Building 7500 W. 29"' Ave, Wheat Ridge, CO 80033-8001 P 303.235.2846 F: 301235.2857 DATE: September 10, 2015 T(t',': Accounting Department FROM: Meredith Reckert, Senior Planner SUBJECT: ESCROW REFUND/RELEASE Reimbursement requested for funds in the amount of $7000.00 (seven thousand dollars and no cents) being held for landscaping for the following properties located within the Doud Overlook Subdivision (Fireside development). all Ifilit! Nii I 10WIV Greenwood Village, CO Sol 11, www-cLwheatrldge.co.us 11 14, City of Owner/Occupant 11871 W. 39th PI. Wheat Rid e. CO 80033 RE: Previously permitted project plans available for retrieval — Permit ##201400668 (New Single Family) Owner/Occupant, This letter is being sent to you because a project for which a permit was issued by the City of Wheat Ridge Building Division and plans and/or other documents were required was recently completed and approved. In accordance with the Building Division's document retention policy, the associated plans and/or other documents are scheduled for disposal. We are writing to offer you an opportunity to retrieve those approved plans and/or documents prior to their disposal by the Building Division. The plans and/or documents are available for retrieval for a period of 15 working days (3 weeks) from the date of this letter and must be retrieved in person at the Building Division offices. This letter must be presented at the time of retrieval of the plans and/or documents. Plans and/or documents available for retrieval CANNOT be mailed and plans and/or documents will NOT be available for retrieval after the expiration of the retrieval period, which is 60 days from the date of this letter. You may retrieve plans and/or documents between the hours of 7:30 a.m. and 3:30 pm., Monday through Friday, at the Building Division offices located at 7500 W. 29h Avenue in Wheat Ridge, am= M Melissa Mackey elissa Mac Senior Permit Technician 7500 W 29t�h Avenue Wheat 4R"ide, Colorado 800 7NywwFax: 303-234-2857 j ,cJ.mrheatridge.co.u,s www ri whoutridao on tie r . installed In the event that right-of-way paving is not by 06/01 i Approved and Agreed: '* 4 Ir City of Escrow/Letter of Cred O�Wh6atl d e -�COMMUWTY DEVELOPMENT � Transmittal Sheet I Z Landscaping under Planning & Development: front yard landscaping on Z Other: Escrow expires June 1, 2015 KAMM - 5 Name Date City of Wheat Ridge Memorandum TO: Accounting FROM: Melissa Mackey, Building Division 4CATE: August 14 2014 Reason: Please refund half the plan review fee to Permit #201400668, for 11871 W. 39 th Place. Please refund: Contractors License$ ( Total: $917.13 At r" o -I Vok M*r7I a Z I City of - �qr Wh6atPjdge c UNrry DEVELOPMENT Building & Inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office 303-235-2855 * Fax: 303-237-8929 Inspection Line 303-234-5933 Building Permit Application bljhjg��� Wo• dley Architectural Group / Felten Group Architect/Engineer E Jacob.Morgan@Feltengroup.com Phone: Woodley (303) 683,7231 Contractor: Same as Above MEE= W, R. City License 080261 Plumbing, Plumbing Unlimited, Inc. Mechanical: Smith & Willis HVAC W R City License 140008 WR City License 80256 Other City Licensed S& City License # Complete all information on BOTH sides of this form 5058 Plan V add basement bath rough-in, Gas Line to Range/Cooktop, Covered Patio, add rail Fireplace - Novus Paint Grade Shelves, A/C, Sq. FULF Stu's Squares pjilijlilii at Great Room overlook, r. 71A ,04 fir' r 361,268.84 3' OWNEWCONTRAC7FOR If OF UNDERSTAN DING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of'Wheat Ridge codes and ordinances for work tinder any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work andarn also authorized by the legal owner ofany entity included on this application to list that entity on this application. CIRCLEONE. (OWNER) (CONIRACTOR) err (AUTHORIZED REPRESENTATIVE) of (OffIXER) (CONTRACTOR) . Building Division Valuation: gm�. I � MSU P1 3 HTA R M Parcel ID: 39-204-05-017 Progerty lyge: Lgricultural Property Address: VACANT LAND Mailing Address: 07800 E DORADO Pl. 220 GREENWOOD VILLAGE CO $0111 ---------- - M ---------- rA2hj.q Parcel Man ----------- ---- ikecepiion ----------- STIMP MOMMEW MWIPM.M.4m.m.mm WIFE— rA2hj.q Parcel Man ikecepiion ikecepiion I * 1 . 1 e 1 Date * This , application, must be signed by each sub-contractor confirnong th sawc. Rev. 02/2014 Address: loud Subdivision, Filing 2, Lot #: Applicable survey conditions: FND (survey at foundation) NRS (survey prior to CO, if within 2 feet of setback) DOUDI (landscaping) DOUD2 (setbacks) q. f. Maximum Building Coverage (40%): 3 '2 1 ') _ sq Total Proposed Building Coverage: sq.ft. Setbacks: Required I Provided Interior Rear 1511 Perimeter Rear 11 Is the structure within 2 feet of minimum setbacks? — e C (If yes, add surveying condition FND.) U lag= A= City of --� '�Wh 6 atRiOge PUBLIC WORKS City of Wheat Ridge Municipal Building 7500 W, 29"' Ave. Wheat Ridge, CO 90033-8001 P 303,2351861 F: 301235,2857 PUBLIC WORKS DEVELOPMENT 8 F EES Date: P ent R&AoxYroc !��w —essi Fee. (Required of all projects for document processing) $50.00 !EoLnmerciaUju_16-FamiIv Review Fees: * Review of existing or minimal technical documents: ... $2oo00 # Initial review' oft chnica civil engineering documents (Fee includes reviews of the 1" and 2 "d submittals):. ...... $600A0 * Traffic Impact Study Review Fee: Fee includes reviews of the I" and 2 nd submittals):,, .... . ........... $S00.00 # Trip Generation Study Review Fee: ........... ............. ............ $200.00 0 0 &. Manual Review & S Recording Fee ... ...... ........ . $1 00 00 It Application will be reviewed by staff once and retu ied f r n 0, chan i es. If after i eviem of "a 4W&W"4" to the following Resubmittal Fees.' Y Wal T, furtner reviews OT Me Application will be subjew # Resubmittal Fees: TOTAL REVIEW FEES (due at tinte of Building Pentrit issuance): PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL 13E ADDITIONAL LICENSINC, AND PERMITTING FEES REQUIRED FOR CONSTRUCTION OF IMPROVEMENTS 'WITHIN PUBLIC RIGHT-OF-WAY. Www-d-wheatridge.co.us Rev 12,12 5. NOT ALP_ROVED. The Public Works Department has reviewed the submitted material and does not approve this Permit Application for the stated reason(s): Sigi?ature David F. Brossman, P.L.S. Date el 6. _ Stipulations: T _ A Drainage Certification Letter accompanied by As-Built plans from the Engineer-of-Record shall be required prior to the issuance of the Certificate of Occupancy. 8. NOTE: ANY DAMAGE TO EXISTING PUBLIC IMPROVEMENTS AS A RESULT OF PROJECT CONSTRUCTION SHALL BE REPAIRED PER ROW CONSTRUCTION PERMIT PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY, Rev O6/201 W000l C « « o , L to V ,, ) , CL Lu o A .. Ole s -s 1 t m 0 0 v G ui G 0 C14 cad ra rN 0 �k m 0 c 't"_ °; dO3 w N Q ` l' !1 I F 3Q /3n ,o L co c 00 P4 tg F m QW co c0 m tv co mot, o LLJ > t t �afa t- t 0 OD � Co 0- i 'x 'o 8 F r d ) w �• r tC, N1 -° a C 0'8 .got ss CL MZ 4 t t2 00 OF- m =U')1 : 0 ! 0 -s 1 t m 0 0 v G ui G 0 C14 cad ra rN 0 �k c 't"_ °; N !1 I F m mot, :aW �afa N 0 OD -s 1 t m 0 0 v G ui G ra rN • a a w r +� •t � •a •a 1 oo vi d0 `jai +.7f].!. «.., m..,.,......» e...".. mm. �....•.. a..... ,.,�«�..,»�. "..w.......«»�„",". �F'�,t .M....m.,.....«.. «.".v., m t m ww �� ...,.,. m,,. � .............».,..«.,,,.,,««, ....,...:.�.....,..,,.,«,,..,.. z s (� fry(^ o /�! 7V{ 3 d « F �y + q V C 517 t73 t " ci C4 ' < tL �,.. _,...,. .. _... ........ _. .. .. ..... .. ...m .... ...... ... ..... ....... ._ .......... .. .. ...... _. .._... ' e+ ° toal ` *S AOS L L'L� LLJ (I 3 1 ig X tJ 6 L'G P OD ct � V "L 19, OT oo Cry a. C�9 u . (P (9 ,9 . 6t "ua w Z5 KIN LLJ z ^a.. X01 (p 6 %. � � e s ` wS to � CD 4 4i Q° Q ut tD h - u�csa £sir ri � 0 0 1 . � P-) 0; u>u? ep II1 I Q x En l cO [ t L Z t Sv K? � w ea te e' `` 30/3n q �- 44 d to c6 :NH3 r A -40 c ° `jai al m t m ww z s �y + q V C 517 t73 t " ci C4 ' < tL LLJ 6 "a. w Z5 KIN LLJ z ^a.. Q wS to Q ut a c u U En K? � w ea d to :NH3 -40 c e §: \� a § \\ C14 $ «§z• i ko » 6 §\� AAGw. "X�assenaar 2180 �South Ivearshoe Strtaot, S"ite 5 04anvoar, CcAc>racIc> 80222-5710 303-759-8100 Fax 303-756-2920 www,agwassenaar.com EM W ♦ As requested, we have performed a soil and foundation study at the subject site. The purpose of our study was to observe subsurface conditions encountered and to recommend geotechnical design criteria for the design and construction of the foundation for the proposed residence. This letter presents a summary of our findings and recommendations 0' to 4 Fill, sand, medium dense, silty, slightly clayey, slightly gravelly, moist, mottled brown Project Number 135300 December 10, 2013 Page 2 IT 7117 Project Number 135300 December 10, 2013 Page 3 Based upon our evaluation of the subsurface conditions at this site, it is our opinion that the slab performance risk for this site is low, If this risk of movement is not acceptable, engineered interior floors should be constructed. TOM P IT - e - r(d TIT*�VerfTeTn, , t I 10 a( , T � 5 _ -PVS'e following criteria: us snol , Te sleivara i Forn TxTerfurli a joint which allows free vertical movement of the slab. M, all 228=0 MMIMMEEM33=0 We are available to provide further consultation regarding basement slab performance risk assessments. During construction, the crawl space area should be checked for standing water or very moist conditions, construction debris, and other deleterious materials. If these conditions exist, the area ghould be evaluated and mitigated, as necessary. Project Number 135300 December 10, 2013 Page 4 - CA-C-1. C .. � - ;r '77 1167 rayrWrrv. I "It 17 ' t'7# - ,(7tJ'Tff rt, 7#11 as much as practical during construction. Z The ground surface surrounding the exterior of the foundation should be maintained in such a manner as to provide for positive surface drainage away from the foundation. At completion of construction, we recommend a minimum fall away from the foundation of 6 inches in the first 5 feet. This slope should be continuous across the backfill zone. 3. Backfill around the foundation should be moistened and compacted in such a manner as to reduce future settlement. Areas which settle should be filled as soon as possible in order to maintain positive drainage away from the foundation. y a Project Number 1353i1 - •_ 0, 2013 Page 5 4. If lawn edging is used around the exterior of the foundation, it should s- • - + in a manner to prevent ponding • surface water in the vicinity of the backfill soils. 5 All drainage swales should be constructed and maintained a minimum of 5 feet away from the foundation • side yards and 15 feet away from the foundation • back and front yards, Drainage swales should maintain a slope • at least 2% off of the lot. Swales must not be blocked by fences, landscaping, paths or other Homeowner installed items. 6 Roof downspouts and drains should discharge well beyond the limits • foundation backfill. 7. Watering adjacent to the foundation should be reduced as much as practical, Landscaping which requires excessive watering should not be located within 5 feet of foundation walls. Main sprinkler lines, zone control boxes and drains should be located outside the limits • the foundation backfill. Sprinkler heads should be positioned such that the spray does not fall within 5 feet of foundation walls. & Plastic membranes should not be used to cover the ground surface immediately surrounding the foundation, These membranes tend to trap moisture and prevent normal evaporation from occurring. We recommend the use ♦ a weed suppressant •eotextile fabric, Standard Pacific of Colorado, Inc. Project Number 135300 December 10, 2013 Page • go= 19 W, b" n a ;Idd Taylor, Jr., � LJ re ' nt BACKFILL— # # # # ar THE FOUNDATION. zsul# # Gootachnica! and EnvironmentM Gonsuicants • FOOTING # #. DRAIN a DETAIL NOTES: 1 e DRAIN MUST SLOPE TO A POSITIVE GRAVITY OUTLET AND /OR TO SUMP WHERE WATER CAN BE REMOVED BY PUMPING 2. SLOPE BOTTOM OF TRENCH AND PIPE AT A 7. `7 MINIMUM OF 1 /8" PER FOOT (I.e. 10/6) 3, 3 OR 4 -INCH DIAMETER RIGID PERFORATED PVC PIPE (A TM D2729 MINIMUM SCHEDULE 20), OR AN °y APPROVED SUBSTITUTE FOUNDATION 4, GRAVEL SPECIFICATION: 2" MINUS WASHED WALL ROCKIGRAVEL, POORLY GRADED WITH NO MORE THAN 30% PASSING THE 318° SIEVE AND NO MORE THAN 10% PASSING THE #4 SIEVE, OR AS APPROVED BY THE GEOTECHNICAL ENGINEER BACKFILL NON -WOVEN GEOTEXTILE FILTER FABRIC (MIRAFI 140N OR EQUIVALENT) PLACED OVER ENTIRE WIDTH OF DRAIN GRAVEL. DRAIN GRAVEL - (SEE NOTE 4) GRAVEL SHALL FILL ENTIRE TRENCH AND EXT LATERALLY TO EDGE OF FOOTING AND UP AT LEAST 2" ABOVE BOTTOM OF FOOTING WITH A MINIMUM OF 3" OF GRAVEL COVER ABOVE PIPE AT HIGH POINT. /–SLIP ,JOINT CONCRETE SLAB BACKFILL— # # # # ar THE FOUNDATION. zsul# # Gootachnica! and EnvironmentM Gonsuicants • FOOTING # #. DRAIN a DETAIL APPROVED �Ptan ecked Equipment Furnace = Carrier Model 5 SC2S100S21 - -22 (80000 BTU) Air Conditioner = Carder Model CA13NA042 * * * * (A,8) (3.5 Ton) Evaporator Coil = Carrier Model CNPV *4 21AL * +TDR (4 Ton) Duct Summary Report units: Pressure: in.wg, Duct lengths feet, Duct sizes: inch, Arflow CFM, Veloc y: ft.hnin, Temperature: F Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply, they are at the exit. The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered, and the emulative may also include the total static pressure loss of the return side. Number of active trunks. 3 Number of active runots: 33 Total runout outlet airflow: 1,77 Main trunk airflow. 1250 Largest trunk diameter: 18.6 ! -100 Largest runout diameter 7 SR -100 Smallest trunk diameter: 12 ST -210 Smallest runout diameter; 4 SR-280 Supply tan external static pressure: 0.800 Sopplyfan device pressure losses: 0.2 Supply fan static pressure available: 0.504 Runout maximum cumulative static pressure loss: 0.469 SR -220 Return loss added to supply: 0.1: Total effective length of return (ft.): 366.0 Ceiling RA Total effective length of supply( ft.): 202.5 SR-220 Overall total effective length (ft.): 66H Ceiling RA to SR-220 Design overall friction rate per 100 ft.: 0.088 (Available SP x 100 /TEL) System duct surface area (do Scenario): 1154.8 System duct surface area (Scenario 1): 302.5 Attic (Linked to duct load) Total system duct surface area: 1457.8 Ma"ISTIOM - pii ml, °._ k4"m4`p"S'p... , p 6 • M # rS mm F#, , . ; #*. # " V d t ' e 4 € 4 # ° a ## 41 4 # ° a ## 41 MOM 4 � �� �w� SR- 390$6 %54 CFM,Reg: I OA Z M350,6 Standard Pacific Basement Fireside Plan 5058 North SR 3W,654 CFM,RegAOx4 wl O'X* 0MG4diel W4 'R ",25 CPM.ReqA OX4 Scalel /8"=1'0" Drawn: Approve& Date: Job Number ", 5 SR 220,7 CFM.,Req :1 Ox4 SR-230,7 %73 CF�M.R9910.4 SR.261,7";7i CFM,Reg:4tkX4 SR ",71 C;FM,Reg:tOX4 SR 240,6,66 CFPk,Fte9..90x4 { S'R 411,6 ' ,5601k1R i0x4 Sra 2 10,7 %78 CFA *,RegAQl4 eu` r SR 251.6 ",S6 CFM,Aag 16X4 , MstXrrdgtr.7 ",r >cFna,Cr�FC S k' i 1 i ;,✓ 'MSk Hy;;kkX,77CFM,G11§o.'k Low, CiFM,C*YWe 12a4`r i v E t ✓ v = -4� W C. aw,7',7i CFM,Gra &Pa;17.x Gseak R�rcuza � gg °'f ✓ , 'SR-2y0,4'j5CF'M,Reg :tOv g k 4 H"t,7`,H1 CFM,Grsie 12a£r s .a� µ.,. .F xo,1C ,3G0 CFtAGrWe14x8 SR- 280,4 °,1OCFV,,Req:16X4 Hgh,7 "80 UM'GraW IN6 x # �,� Z Y1C g 3 1 t ii i � Dmin%'Orrt Study tMa to, silt, " MW ftuern j r� I E iEt 666 H19h,7',80 CFM,&*e: t2x6 . SR 310.6 ",17 CFM,R -9:11x4 1 SR 320,4 ',18 CW,Re IN SR- M,y,42 C#yAIA09HOX4 1 1 F i SR 190'6":15 ,,..,rl..�'- Y SR 200,7•.67 cFM.Raw r¢Xa � �� PWdi ttr " +o a fl V, ,241Nf sXC%ogUS$ Pi1Xi Laundfy t � t �� [ � SlI 330,4 °,13 C~FM,Re9.11X4 d� C Batt, 3 CaA { F 5R 360,7 ",.53 L' a,.eg.SCx4 SR -44 X,53 CrM,8eq!1Qx4 em81ze:11 x1 7-,. Standard Pacific in Floor Fireside Plan 5058 5ca1e:118 ":1'0" Drawn: Approved: j Date: Job Number: z igmium" A - ---------- --- . ........... ....... . ............ .. --- ------- A, Lj) 14 *0 ------------ Ous ---- - - - ------ Winter: 1 0.21 81% 30% 70 34.16 Summer: 91 59 15% 50% 75 -39.04 NMI Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0,1000 in.wg./100 ft. 0A000 in.wg./I 00 ft. j Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in 0 in. Winter Summer Infiltration Specified: 0.250 AC/hr 0.250 AC/hr 166 CFM 166 CFM Infiltration Actual: 0.294 AC/hr 0.294 AC/hr Above Grade Volume: X 39 891 Cu.ft. X 39891 Cut. 11,732 Cu.ft./hr 11,732 Cu,ft./hr X 0.0167 X 0,0167 Total Building Infiltration: 196 CFM 196 CFM Total Building Ventilation: 0 CFM 0 CFM - System 1 Infiltration & Ventilation Sensible Gain Multiplier: 1439 = (1.10 X 0.817 X 16,00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: -21 = (0.68 X 0.817 X -39,04 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 62.04 = (1,10 X 0.817 X 69.00 Winter Temp, Difference) I Winter Infiltration Specified: 0.250 AC/hr (166 CFM) Summer Infiltration Specified: 0,250 AC/hr (166 CFM) ��16B��O�O6�8 pi �1S�upply Attic Attic 302.9 'Yes 1 Return Attic Attic 16B 0,06 8 10.5 Yes . ........... Wednesday, February 12, 2014, 11:15, ......... .... . . ................ . ------- - ----- ---- ------------- ------------ --------- - ---- I �' se Sera( Le i Net, Sen 1 y s' tg� S CIg! S Actj D'ct Scope Ta ffo' Are a! a: n G i[ ,,,, G m Gam� Loss� CF CFMj_ " a_ ' I BrAfing MI 2,477 5,817 31,316 -3,139 31,316 63,736 1,222 1,279 1979 systern 1 2.61 2,477 5,817 31,316 -3,139 31,316 63,736 1,222 1,37'9' 1,279 25x12 Duct Latent -96 0 Humidification 3,155 Zone 1 5,817 31,316 -3,043 31,316 60,582 1222 1,279 1,279 16x1 I-Rec Room 1,331 1,883 -215 1,883 8,014 Iw 77 162 6,6,6 2-Bedroom 4 201 844 154 998 1,677 34 34 34 6 3 -Bath 4 58 35 -25 35 698 14 1 14 4 4-Mech 622 61 -49 61 3,435 69 3 69 6 5 -Crawl Space 248 0 0 0 1,245 26 0 25 4 6-Casita 271 2,617 -463 2,617 5,263 106 107 107 7,7 7-Casita Bath 56 329 -56 329 659 13 13 13 4 8-Laundry 43 604 0 604 82 2 25 25 Not MM 1­4 9-Pwdr 27 35 0 35 51 1 4 1 Not MM 1 10-Mstr WIC 2 90 258 -90 258 882 18 11 18 4 11 -M aster Bath 226 914 -138 914 1,769 36 37 37 6 12-W/C 20 238 -31 238 397 8 10 10 4 13-Mstr WIC 52 194 -81 194 740 Is a 15 4 14-Master Bedroom 301 3,480 -161 3480 4,909 99 142 142 7,7 15-Great Room 334 4,145 -262 4,145 5,375 108 169 169 6 16-Nook )Ktohen 467 5,757 -539 5,757 6,390 129 235 235 7,7,7 17-Mud Room 74 823 -186 823 2,073 42 34 42 6 18-Dirfhg/6 pt Study 227 816 -176 816 1,754 35 33 35 6 19-Foyer/Hall 271 1,645 -261 1,645 3,139 63 67 67 7 20•Bedroom 3 232 2237 -143 2,237 3,785 76 91 91 7,7 21 -Bath 2 59 148 -47 148 480 10 6 10 5 22•Bedroom 2 202 1,687 -62 1,687 2,930 59 69 69 7,7 23•Bonus/ Opt, BR4 195 1,602 23 1,625 2,354 47 66 65 7" 24-Bridge 210 964 -235 964 2,481 50 39 50 7 Suns of room airflows may be greater than system airflow because system room airflow option uses the greater of heating or cooling, YA.,AStandard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM N-46;-e ) Trunk 0.0003 1 - 8 .6 Up. Fan 55 25 Rect 01 12 Presize 1,250 4,6 -- -Duct Name: ST-1 10, Feeds Into: Mech, Effective Length: 1.2 0.000 Trunk 0.0003 18.6 Up: SMT- 100 55 25 Rect 12 12 Presize 1,250 7,2 600 0.000 0.028 0.012 43.8 0.309 4.365 O 435 I 1111 Trunk 0.0003 12.9 279 0.000 Up: ST-370 55 14 0.011 0.000 Rect 4.2 10 0.0 0.000 Presize 271 161 0.350 0.450 Trunk 4.0003 15.2 180 0.000 Up: ST-370 55 20 0.004 0.000 Rect 2.5 10 0,0 0.000 Presize 250 12.5 0.350 0,450 -- -Duct Name: ST-140, Feeds Into: Bridge, Effective Length: 3.5 Trunk 4.0003 12,9 76 0,000 Up: ST -120 128 14 0.001 0.000 Rect 3.5 10 0.0 omo Presize 74 14 0.350 0.450 -- -Duct Name: ST-150, Feeds Into: Bridge, Effective Length: 2.0 Trunk 0.0003 12.9 205 0.000 Up ST-120 55 14 0.006 0.000 Rect 2.0 10 0.0 0,000 Presize 199 8 0.350 0,450 ._..Duct Name: SR-100, Supplies: Bedroom 3, Fittings: 2-1,4-AD, Effective Length: 54.7 Runout 0.01 7 172 0.004 Up: T -170 55 5.4 0.013 0.004 Rnd 27.4 7.7 27,3 0.007 Presize 46 502 0.342 0.458 -- -Duct Name: SR-110, Supplies: Bonus/ Opt. BR4, Fittings: 2-1,4-AD, Effective Length: 41.9 Runout 0.01 7 124 0.001 Up: ST-140 55 5.4 0.007 0.002 Rnd 15.5 73 26.5 0.003 Presize 33 28.4 0.347 0.453 - --Duct Name: SR-120, Supplies: Bonus/ Opt. BR4, Effective Length: 13.0 Runout OV 7 124 omi Up: ST-150 55 5.4 0.007 0.000 Rnd 13.0 73 0.0 0.001 Presize 33 219 0.343 0.451 d,2rd P_q.cific Fireside R2-n 505R Wednesday, February 12, 2014,11:15 AM A" _..Duct Name: ST-160, Feeds Into: Bridge, Effective Length: 0.8 Runout 0,01 7 Trunk 0.0003 12,9 171 0.000 Up: ST-150 55 14 0,005 0.000 Rect 0.8 10 0.0 0.000 Presize 166 3.3 0.350 0.450 ---Duct Name: SR -130, Supplies: Bedroom 2, Fittings: 2-1, 4-AD, Effective Length: 38.0 Runout 0.01 7 127 0.001 Up: ST -170 55 5.4 0.008 0.002 Rnd 11.5 71 26.5 0,003 Presize 34 21 0.347 0,453 ---Duct Name: SR -140, Supplies: Bath 2, Fittings: 2-1, 4-AD, Effective Length: 30.2 Runout 0.01 5 73 0.000 Up: ST-200 128 3.9 0.004 0001 Rnd 10.0 5.5 20.2 0,001 Presize 10 13.1 0.348 0.452 -- -Duct Name: ST-170, Feeds Into: Bedroom 2, Effective Length: 1.0 Trunk 0.0003 12.9 82 0.000 Up: ST-200 55 14 0.001 0,000 Rect 1.0 10 0.0 0.000 Presize 80 4 0.350 0,450 -- -Duct Name: SR -150, Supplies: Bridge, Fittings: 2-1, 4-AD, Effective Length: 41.9 Runout 0.01 7 187 0.002 Up: ST-140 128 5.4 0.014 0.004 Rnd 10.8 7.7 31.0 0.006 Presize 50 19.9 0.344 0.456 -- -Duct Name: SR-160, Supplies: Bedroom 3, Fittings: 2-1,4-AD, Effective Length: 54.0 Runout 0.01 7 172 0.004 Up: ST -190 55 5.4 0.013 0,004 Rnd 26.7 7.7 27.3 0.007 Presize 46 48.9 0342 0.458 -- -Duct Name: ST-180, Feeds Into: Bedroom 2, Effective Length: 2.7 Trunk 0.0003 12.9 171 0,000 Up: ST -160 55 14 0.005 0,000 Rect 2.7 10 0.0 Omo Presize 166 10.7 0.350 0.450 _. -Duct Name: SR-170, Supplies: Bedroom 2, Fittings- 2-1,4-AD, Effective Length: 36.1 Runout 0,01 7 127 0.001 Up: T -180 55 5.4 0.008 0,002 Rnd 9.5 7.7 26.5 0.003 Presize 34 17.5 0.347 0.453 -- -Duct Name: ST-190, Feeds Into: Bridge, Effective Length: 4.3 Trunk 0.0003 12.9 136 0,000 Up: ST -180 55 14 0.003 0.000 Rect 4.3 10 0.0 0,000 Presize 132 17.3 0.350 0A50 Wednesday, February 12, 2014,11:15 AM Ductsize Data - Duct - --Duct Name: ST -200, Feeds Into: Bedroom 2, Effective Length: 5.7 Trunk 0.0003 12.9 89 0.000 Up: ST -190 55 14 0.001 0.000 Rect 5.7 10 0.0 0.000 Presize 86 22.7 0.350 0,450 -- -Duct Name: SR -180, Supplies: Mud Room, Fittings: 2 -1, 4 -G, Effective Length: 701.2 Runout 0.0003 6 214 0).002 Lip: ST -380 123 43 0.014 0.008 Rnd 14.0 6.6 56.2 0.010 Presize 42 22 0.340 0.460 ..Duct Name: ST -210, Feeds Into. Rec Room, Effective Length: 3.2 Trunk 0.0003 12 228 0,000 Up: T -380 55 12 0.008 0.000 Rect 3.2 10 0.0 0.000 Presize 190 11,6 0.350 0.450 -- -Duct Name: SR -190, Supplies: Dining /Opt Study, Fittings: 2-1,4-G, Effective Length: 64.0 Runout 0.0003 6 178 0.002 Up. ST -400 128 4.7 0.010 0.005 Rnd 16.5 6.6 47.5 0 «007 Presize 35 25.9 0.346 0.454 -- -Duct Name: ST -220, Feeds Into: Rec Room, Effective Length: 3.3 Trunk 0.0003 16.9 378 0.000 Lip. ST -400 55 25 0.014 0.000 Rect 33 10 0.0 0.000 Pres 656 19.4 0.352 0.448 -- -Duct Name: SR -200, Supplies: Foyer /Hall, Fittings: -I, 4 -H, Effective Length: 57.5 Runout 0.0003 7 251 0.003 Up: ST-26O 55 5.4 0.017 0.007 Rd 15.3 7.7 42,1 0.010 Presize 67 28.1 0345 0.455 -- -Duct Name: ST -230, Feeds Into: Rec Room, Effective Length: 3.7 Trunk 0.0003 16.9 475 0.001 Up: ST -260 55 25 0.022 0.000 Rect 3.7 10 0.0 0.001 Presize 824 21.4 0.354 0.446 -- -Duct Name: SR -2101, Supplies: Nook /Kitchen, Fittings: 2 -1, 4 -H, Effective Length: 62.3 Runout 0.0003 7 292 0,004 Up. T -240 55 5.4 0.022 0.010 Rnd 18.7 7.7 43.7 0.014 Presize 78 34.2 0.336 0.464 -- -Duct Name: SR -220, Supplies: Nook /Kitchen, Fittings: 2 -1, 4 -G, Effective Length: 85.3 Runout 0.0003 7 292 0.005 Up: ST -210 55 5.4 0.022 0.014 Rnd 22.7 73 62.7 0.019 Presize 78 41.5 0.331 0.469 .� a q _ - - D uct Nam S T-240, Feeds Into: Rec Room, Effective Length: 2.7 Trunk 0.0003 12 134 0.000 Up: ST -210 55 12 0.003 0.000 Rect 2.7 10 0.0 0.000 Presize 112 9.8 0.350 0.450 -- - Naive: SR -230, Supplies: Nook/Kitchen, Fittings: 2 -1, 4 -G, Effective Length: 81.5 Runout 0.0003 7 292 0.005 Up: ST -370 55 5,4 0.022 0.013 Rnd 22.7 71 58.9 0.018 Presize 78 41.5 0.332 0.468 -- -Duct Name: SR -240, Supplies: Great Room, Fittings: 2 -1, 4 -G, Effective Length: 60.4 Runout 0,0003 6 285 0.004 Up: ST -220 55 4.7 0.026 0.012 Rnd 15.3 6.6 45.1 0.016 Presize 56 24.1 0336 0.464 --- Duct Dame:. ST -250, Feeds Into: Rec Room, Effective Length: 1.7 Trunk 0.0003 15.2 432 0.000 Up: ST -220 55 20 0,020 0.000 Rect 1.7 10 0.0 0.000 Presize 600 8.3 0.352 0.448 -- -Duct Name. R -250, Suppl Great Room, Fittings: 2 -1, 4 -G, E ffective Length: 66.6 Runout 0.0003 6 285 0.004 Up: T -310 55 4.7 0.026 0.013 Rnd 15.3 6.6 513 0.017 Presize 56 24.1 0.338 0.462 -- -Duct Name: ST -260, Feeds Into. Rec Room, Effective Length: 2.3 Trunk 0.0003 16.9 513 0.001 Up: ST -310 55 25 0.025 0.000 Rect 23 10 0.0 0.001 Presize 891 13.6 0.355 0.445 -- -Duct Name: SR -260, Supplies: Master Bedroom, Fittings. 2 -1, 4 -G, Effective Length; 76.7 Runout 0.0003 7 266 0.004 Up: ST -330 55 5.4 0.019 0.010 Rnd 22.8 7.7 53.9 0.014 Presize 71 41.8 0.346 0.454 -- -Duct Name. T -270, Feeds Into: Mech, Effective Length: 4.5 Trunk 0.0003 18,6 506 0.001 Up: ST -410 55 25 0.021 0.000 Rect 4.5 12 0.0 0.001 Presize 1,055 27.8 0361 0.439 -- -Duct N ame: SR -270, Supplies: Master Bedroom, Fittings. 2 -1, 4 -G, Effective Length. 93.4 Runout 0.0003 7 266 0.004 Up: ST -280 55 5.4 0.019 0.013 Rnd 22.8 7.7 70.6 0.018 Presize 71 41.8 0347 0.453 Y:\ ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 1, 2014,11:15 AM Trunk 0.0003 18.6 599 0.001 Up: ST-110 55 25 0.028 0.000 Rect 2.0 12 0.0 0.001 Presize 1,247 123 0,364 0,436 - -- - Duct Name: SR-280, Supplies. WIC, Fittings: 2-1, 4-H, Effective Length: 27.5 Runout 0.0003 4 115 0.000 Up: ST-360 55 3.1 0,009 0.002 Rnd 42 4.4 23.4 0.002 Presize 10 4,4 0.362 0A38 -- - Duct Name: ST-290, Feeds Into: Mech, Effective Length: 1.0 Trunk 0.0003 18.6 550 0.000 Up: ST-360 55 25 0.024 0.000 Rect 1.0 12 0,0 0.000 Presize 1,145 62 0.364 0.436 -- - Duct Name: ST-300, Feeds Into: Mech, Effective Length: 0.7 Trunk 0.0003 18.6 565 0.000 Up: ST-280 55 25 0.025 0,000 Rect 0.7 12 0.0 0,000 Presize 1,176 4.1 0.364 0.436 -- - Duct Name: ST-310, Feeds Into: Rec Room, Fitting: 12-01, Effective Length: 19.4 Trunk 0.0003 16.9 546 0.002 Up: ST-330 55 25 0.028 0.003 Rect 8.8 10 10.5 0.005 Presize 947 51.5 0.355 0.445 --Duct Name: SR-290, Supplies: Mstr WIC, Fittings: 2-1,4-H, Effective Length: 31.8 Runout 0.0003 4 172 0.000 Up: ST-360 128 3A 0.016 0,005 Rnd 3.0 44 28.8 0.005 Presize 15 3.1 0.359 0,441 -- - Duct Name: SR-300, Supplies: Casita, Fittings: 2-1, 4-G, Effective Length: 99.7 Runout 0.0003 7 198 0,006 Up: ST-230 55 5.4 0.011 0.006 Rnd 49.5 73 50,2 0.011 Presize 53 90.7 0.343 0.457 -- - Duct Name: ST-320, Feeds Into: Rec Room, Effective Length: 4.7 Trunk 0.0003 16,9 444 0.001 Up: ST-230 55 25 0,019 0.000 Rect 4.7 10 0.0 0.001 Presize 771 27.2 0.353 0A47 I --- Duct Name: SR -31 Supplies: Master Bath, Fittings: 2-1, 4-H, Effective Length: 43.9 Runout 0.0003 6 188 0.001 Up: ST-270 55 4.7 0.012 0.004 Rnd 11.5 6.6 32.4 0.005 Presize 37 18.1 0.356 0.444 Y:\ ... \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11;15 AM (�e" -- - Duct Name: ST-330, Feeds Into: Rec Room, Effective Length: 2.7 Trunk 0.0003 18.6 489 0,001 Up: ST-270 55 25 0,020 0.000 Rect 2.7 12 0,0 0,001 Presize 1,018 16.4 0.361 0,439 ---Duct Name: SR-320, Supplies: Mstr WIC 2, Fittings: 2-1, 4-G, Effective Length: 53.0 Runout 0.0003 4 206 0.005 Up: ST-350 128 3.1 0.022 0.007 Rnd 21 4.4 31,2 0,01 Presize 18 22.9 0.352 0.448 -- - Duct Name: ST-340, Feeds Into: Mech, Effective Length: 1.0 Trunk 0,0003 18.6 506 0.000 Up: ST-350 55 25 0.021 0-000 Rect 1.0 12 0.0 0.000 Presize 1,055 6.2 0.363 0.437 --- Duct Name: SR-330, Supplies: Casita Bath, Fittings: 2-1, 4-G, Effective Length: 66.5 Runout 0.0003 4 149 0,005 Up: ST-300 55 3A 0.014 0.004 Rnd 363 4.4 29,9 0,009 Presize 13 38.4 0.355 0.445 .... Duct Name: ST-350, Feeds Into: Mech, Effective Length: 1.2 Trunk 0,0003 18.6 524 Omo Up: ST-290 55 25 0.022 0,000 Rect 1.2 12 0.0 0.000 Presize 1,092 7.2 0.363 0,437 -- - Duct Name: ST-360, Feeds Into: Mech, Effective Length: 0.8 Trunk 0.0003 18.6 558 0.000 Up: ST-300 55 25 0.025 0.000 Rect 0.8 12 0.0 0.000 Presize 1,163 5.1 0.364 0.436 - -- Duct Name: SR-340, Supplies: Casita, Fittings: 2-1, 4-G, Effective Length: 111.0 Runout 0.0003 7 198 0.005 1 Up: ST-290 55 5.4 0.011 0.007 Rnd 483 7.7 62.3 0.0 12 Presize 53 89.2 0.351 0.449 -- - Duct Name: SR-350, Supplies: Bedroom 4, Fittings: 2-1, 4-AD, Effective Length: 39.7 Runout 0.0003 6 173 0.001 Up: ST-240 55 4.7 0.011 0.004 Rnd 5.2 6.6 34.5 0.004 Presize 34 8.1 0.346 0,454 -- - Duct Name: SR-360, Supplies: Bath 4, Fittings: 2-1, 4-AD, Effective Length: 39.0 Runout 0.0003 4 160 0.002 Up: ST-250 128 3,1 0.014 0.004 i Rnd 113 4.4 27.4 0.006 1 Presize 14 12.2 0.346 0.454 YA ..AStandard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM /- Ui [��nual D Ductsize Data Duct 1 j6q -- -Duct Name: ST-370, Feeds Into: Rec Room, Effective Length. 5.3 Trunk 0,0003 15,2 431 0.001 Up: ST-250 55 20 4.020 0.000 Rect 53 10 0.0 0,001 Presize 599 261 0.351 0.440 -- -Duct Name: SR-370, Supplies: Mech, Fittings: 2-1, 4-AD, Effective Length: 69.3 Runout 0.0003 6 351 0.003 Up: T -110 128 43 0.034 0.021 Rnd 7.8 6.6 61.4 0.023 Presize 69 123 0,342 0.458 -- -Duct Name: SR-380, Supplies: Rec Room, Fittings: 2-1, 4-AD, Effective Length: 69.9 Runout 0.0003 6 275 0.004 Up: ST-350 128 4.7 01.022 0.011 Rnd 20,5 6.6 49.4 0.015 Presize 54 32.2 0.348 0.452 --- Duct Name: SR-390, Supplies: Rec Room, Fittings: 2-1, 4-AD, Effective Length: 62.4 Runout 0.0003 6 275 0.004 Up: STA 30 128 4.7 0,022 0.009 Rnd 19.8 6.6 42.6 4.014 Presize 54 31.2 0.337 0.463 -- -Duct Name: ST-380, Feeds Into: Rec Room, Effective Length: 2.7 Trunk 0.0003 12 269 Omo Up: ST-130 55 12 0.011 Omo Rect 2,7 10 0.0 0.000 Presize 224 9.8 0.350 0.450 -- -Duct Name: SR-400, Supplies: Rec Room, Fittings: 2-1, 4-AD, Effective Length: 68.5 Runout 0.0003 6 275 0.003 Up: ST-320 128 4.7 4:022 0.012 Rnd 15.7 6.6 52.8 01.015 Presize 54 24,6 0.338 01.462 -- -Duct Name. ST-390, Feeds Into: Rec Room, Effective Length: 1.5 Trunk 0.0003 16.9 429 0.000 Up: ST-320 55 25 4.018 Omo Rect 1,5 10 0.0 0.000 Presize 745 8.8 0,353 0.447 -- -Duct Name: R -418, Supplies: Great Room, Fittings: 2-1, 4-G, Effective Length: 66.6 Runout 0.0003 6 285 0.004 Up: ST-390 55 43 0.026 0.013 Rnd 153 6.6 51.3 0,017 Presize 56 24.1 0.336 0.465 -- -Duct Name: ST-400, Feeds Into: Rec Room, Effective Length: 2.0 Trunk 0.0003 16.9 397 0.000 Up: ST-390 55 25 0.016 Omo Rect 2.0 10 0.0 0.000 Presize 689 113 0.352 0.448 Y:\ ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11.15 AM (L?v PP -- - Duct Name: ST-410, Feeds Into: Rec Room, Effective Length: 5.3 The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk Trunk 0.0003 18.6 506 0,001 Up: ST-340 55 25 0,021 0.000 i Rect 5.3 12 0,0 0.001 Presize 1,055 32.9 0,362 0.438 -- - Duct Name: SR-430, Supplies: Crawl Space, Fittings: 2-1,4-AD, Effective Length: 65.5 Total runout outlet airflow Runout 0.0003 4 287 am Up: ST-340 128 3.1 0.039 0.011 Rnd 37.7 4.4 27.8 0.026 1 Presize 25 39.4 0.337 0.463 1 Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply, they are at the exit. The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered, and the cumulative may also include the total static pressure loss of the return side. Number of active trunks 32 Number of active runouts: 33 Total runout outlet airflow 1,477 Main trunk airflow: 1,250 Largest trunk diameter: 18.6 SMT-100 Largest runout diameter: 7 SR-100 Smallest trunk diameter: 12 ST -210 Smallest runout diameter: 4 SR-280 Supply fan external static pressure: 0.800 Supply fan device pressure losses: 0.296 Supply fan static pressure available: 0.504 Runout maximum cumulative static pressure loss: 0,469 SR-220 Return loss added to supply: 0.126 Total effective length of return ( ft.): 366.0 Ceiling RA Total effective length of supply (ft.): 202.5 SR-220 Overall total effective length ( fit.): 568.5 Ceiling RA to SR-220 Design overall friction rate per 100 ft.: 0.089 (Available SP x 100 / TEL) System duct surface area (No Scenario): 1154.9 System duct surface area (Scenario 1): 302.9 Attic (Linked to duct load) Total system duct surface area: 1457.8 Y:\ ... \Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014, 11:15 AM c os;'� I I Manual D Ductsize Data Duct_,�y -- -Duct Name: RMT-1 00, Feeds From: Mech, Fittings: 5-12, 5-N, Effective Length: 188.4 Trunk 0.0003 18.6 718 0,000 Up: Fan 75 25 0.038 0.072 Rect 03 12 187,5 0.072 Presize 1,496 5.1 -0.054 0A26 -- -Duct Name: RT-110, Feeds From: Mech, Effective Length: 4.0 Trunk 0.0003 18.6 718 0.002 Up: RMT-100 75 25 0.038 0.000 Rect 4.0 12 0.0 0.002 Presize 1,496 241 -0.053 0A25 -- -Duct Name: RT-120, Feeds From: Bedroom 4, Effective Length: 6.0 Trunk 0.0003 12.9 355 0.001 Up: RT-210 75 14 0,016 0.000 Rect 6.0 10 0.0 0.001 Presize 345 24 -0.044 0,116 --- Duct Name: RT-130, Feeds From: Rec Room, Effective Length: 5.5 Trunk 0.0003 7 299 0,001 Up: RT-21 0 75 5.4 0.023 0.000 Rnd 5.5 73 0.0 0,001 Presize 80 10.1 -0,044 0.007 -- -Duct Name: RT-140, Feeds From: Bedroom 4, Effective Length: 1.0 Trunk 0.0003 12.9 355 0.000 Up: RT-120 75 14 0.016 0.000 Rect 1.0 10 0.0 0.000 Presize 345 4 -0.044 0.116 -. -Duct Name: Ceiling RA, Returns From: Bridge, Fittings: 6-L, 6-C, Effective Length: 114.1 Runout 0.01 12 439 0.001 Up: RT-140 75 9.3 0.038 0.043 Rnd 14 111 110.7 0,044 Presize 345 10.5 0.000 0.044 -- -Duct Name: Mstr High, Returns From: Master Bedroom, Fittings: 6-G, 6-C, 12-S, Effective Length: 40.0 Runout 0,0003 7 288 0.001 Up: RT- 160 75 5,4 0.021 0.008 Rnd 2.5 7.7 37.5 0.008 Presize 77 4.6 -0.042 0.008 -- -Duct Name: RT-150, Feeds From: Rec Room, Effective Length: 2.0 Trunk 0.0003 18.6 463 0.000 i Up: RT-160 75 25 0.017 0.000 Rect 2.0 12 0.0 0.000 1 Presize 965 123 -0-050 0,122 ---Duct Name: Mstr High, Returns From: Master Bedroom, Fittings: 6-G, 6- C,12 -, Effective Length: 40.0 Runout 0,0003 7 288 0.001 Up: RT-170 75 5.4 0.021 0.008 Rnd 2.5 73 37.5 0.008 Presize 77 4.6 -0.042 0.008 Wednesday, February 12, 2014, 11:15 AM L Manual D Ductsize Data - Dqq� -- - Duct Name: RT-160, Feeds From: Rec Room, Effective Length: 1.2 Trunk 0.0003 18.6 500 0.000 Up: RT- 170 75 25 0.020 0.000 Rect 1.2 12 0.0 0,000 Presize 1,042 7.2 -0,051 0A23 -.-Duct Name: Mstr Low, Returns From: Master Bedroom, Fittings: 6-G, 6- C,12 -S, Effective Length: 43.3 Runout 0,0003 7 288 0.001 Up: T -1 10 75 5.4 0.021 0.008 Rnd 5.8 7.7 37.5 0,009 Presize 77 10.7 -0.044 0.009 -- - Duct Name: RT-170, Feeds From: Rec Room, Effective Length: 5.3 Trunk 0.0003 18.6 681 0.002 Up: RT-110 75 25 0.035 0.000 Rect 5.3 12 0.0 0.002 Presize 1,419 32.9 -0.051 0A23 -- - Duct Name: Bsmt Low, Returns From: Rec Room, Fittings: 6-G, 6-C, Effective Length: 47.0 Runout 0.0003 10 550 0,000 Up: RT-170 75 7.8 0.043 0.020 Rnd 0.7 10.9 463 0.020 Presize 300 1.8 -0.031 0.020 ---Duct Name: Floor, Returns From: Great Room, Fittings: 6-G, 6-C, Effective Length: 48.1 Runout 0.0003 10 550 0.001 Up: RT-150 75 7.8 0.043 0.020 Rnd 1.8 10.9 46.3 0.021 Presize 300 4.8 -0.030 0.021 -- - Duct Name: RT-180, Feeds From: Rec Room, Fitting: 12-FI, Effective Length: 23.6 Trunk 0.0003 16,9 383 0.000 Up: RT- 150 75 25 0.014 0.003 Rect 3.3 10 203 0.003 Presize 665 19.4 -0.047 0.119 -- - Duct Name: Low, Returns From: Dining/Opt Study, Fittings: 6-G, 6-C, 12-S, Effective Length: 40.0 Runout 0,0003 7 299 0.000 Up: RT-220 75 5.4 0.023 0,009 Rnd 2,2 7.7 37.8 0.009 Presize 80 4 -0.037 0.009 -- - Duct Name: RT-190, Feeds From: Rec Room, Effective Length: 10.7 Trunk 0,0003 16.9 291 0.001 Up: RT-220 75 25 0,009 0.000 Rect 10,7 10 0.0 0.001 Presize 505 62.2 -0.045 0.117 -- « Duct Name: High, Returns From: Mud Room, Fitting: 6-F, Effective Length: 26.1 Runout 0.0003 7 299 0.002 Up: RT-130 75 5.4 0,023 0.004 Find 9.8 7,7 163 0.006 Presize 80 18 -0.038 0.006 YA ..AStandard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014, 11:15 AM -- -Duct Name: High, Returns From: Dining/Opt Study, Fittings: 6-G, 6-C, 12-S, Effective Length: 40.3 1,496 Runout 0.0003 7 299 0.001 Up: RT-190 75 5.4 0.023 0.009 Rnd 2.5 73 37.8 0.009 Presize 80 4.6 -0-036 0.009 ---Duct Name: RT-210, Feeds From: Rec Room, Effective Length: 1.5 Smallest runout diameter: 7 Trunk 0.0003 16.9 245 0.000 Up: RT-190 75 25 0.006 0.000 Rect 1.5 10 0,0 0.000 Presize 425 8.8 -0,045 0.117 -- -Duct Name: High, Returns From: Foyer/Hall, Fittings: 6-G, 6-C, 12-S, Effective Length: 40.0 System duct surface area (Scenario 1): Runout 0.0003 7 299 0,000 Up RT-180 75 5.4 0,023 0.009 Rnd 2.2 71 37.8 0.009 Presize 80 4 -0.038 0.009 .- -Duct Name: RT-220, Feeds From: Rec Room, Effective Length: 8.3 Trunk 0.0003 16.9 337 0.001 Up: RT- 180 75 25 0.011 0,000 Rect 8.3 10 0.0 0.001 Presize 585 48.6 -0.046 0,118 IRWIN!! iiiiii !ii III Will III! !I 1 111111 11 I Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply, they are at the exit. The cumulative static pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered, and the cumulative may also include the total static pressure loss of the return side. Number of active trunks. 12 Number of active runouts: 10 Total runout outlet airflow: 1,496 Main trunk airflow: 1,496 Largest trunk diameter: 18,6 RMT-100 Largest runout diameter: 12 Ceiling RA Smallest trunk diameter: 7 RT-130 Smallest runout diameter: 7 Mstr High Runout maximum cumulative static pressure loss 0.044 Ceiling RA Return loss added to supply: 0A26 Total effective length of return ( ft.): 366.0 Ceiling RA System duct surface area (No Scenario): 3161.3 System duct surface area (Scenario 1): 10.5 Attic (Linked to duct load) Total system duct surface area: 326.8 Y:\...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM YA -A Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11.15 AEI Y:\ _\Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014,11 AM Total Bul i fig Su I7 Loads �Glazing-5�55 trium. 11,881 15,943 15,949 Door U-.20: Door-Custom door with u value 39.2 541 0 172 172 Garage Entry: Door-U-Value=,357 R-2.8 17.8 439 0 140 140 Front Entry: Door-U-Value=.l 61 R-6.2 24 267 0 85 85 15B15 -Ow -8: Wall-Basement, , framing with R -1 sill to 1451 5,339 0 130 130 floor in 2 x 4 cavity, core, no board insulation, plus 1 interior finish, wood studs, 8' floor depth i R1 Draped-9: Wall-Basement, Custom, R1 Draped w 6143 2,215 0 24 24 R20 Rim R1 Draped -4: Wall-Basement, Custom, R1 Draped 4' 192 821 0 0 0 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 33717 15,131 0 2,478 2,478 cavity, no board insulation, siding finish, wood studs 168 -38: Roof /Ceiling -Under Attic with Insulation on Attic 2484.7 4,459 0 2,971 2,971 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or I Membrane, R-38 insulation 21 -32: Floor-Basement, Concrete slab, any thickness, 2 24601.1 3,395 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 32' wide 20P-30: Floor-Over open crawl space or garage, Passive, 15.2 37 0 3 3 R-30 blanket insulation, any cover Subtotals for structure: 44,525 0 21,952 21,952 People: 6 1,200 1,380 2,580 Equipment: 0 2,400 2,40V Lighting: 0 0 0 Ductwork: 3,926 -96 2,084 1,988 Infiltration: Winter CFM: 196, Summer CFM: 196 12,131 -4,243 2,813 -1,430 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Humidification (Winter) 8.60 gal/day: 3,155 0 0 0 AFC} Excursion: 0 0 687 687 Total Building Load Totals: 63,736 -3,139 31,316 28,177 Total Building Supply CFM: 1,279 CFM Per Square ft.: 0.220 Square ft. of Room Area: 5,817 Square ft. Per Ton: 2,477 Volume (ft of Cond. Space: 59,173 Total Heating Required Including Ventilation Air: 63,736 Btuh 63.736 MBH Total Sensible Gain: 31,316 Btuh 100 % Total Latent Gain -3,139 Btuh 0 % Total Cooling Required Including Ventilation Air: 31,316 Btuh 2.61 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions, Y:\ _\Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014,11 AM IL Whole Loads 39,2 541 0 172 172 17,8 439 0 140 140 24 267 0 85 85 14513 5,339 0 130 130 614.3 2,215 0 24 24 192 821 0 0 0 33733 15,131 0 2,478 2,478 24843 4,459 0 2,971 2,971 21 A-32: Floor-Basement, Concrete slab, any thickness, 2 2460.1 3,395 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 32' wide 20P-30: Floor-Over open crawl space or garage, Passive, 15.2 37 0 3 3 R-30 blanket insulation, any cover Subtotals for structure: 44,525 0 21,952 21,952 People: 6 1,200 1,380 2,580 Equipment 0 2,400 2,400 Lighting: 0 0 0 Ductwork: 3,926 -96 2,084 1,988 Infiltration: Winter CFM* 196, Summer CFM: 196 12,131 -4,243 2,813 -1,430 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Humidification (Winter) 8.60 gal/day: 3,155 0 0 0 AED Excursion: 0 0 687 687 System I Whole House System Load Totals: 63,736 -3,139 31,316 28,177 Y:\_\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11 A 5 AM ter t Data - yt _ - Whole House Cooling System Type: Standard Air Conditioner Outdoor Model: CA1 3NA042 .... (A,B) Indoor Model: CNPV*4821AL*+TDR Tradename: CARRIER AIR CONDITIONING Outdoor Manufacturer: CARRIER AIR CONDITIONING AHRI Reference No.: 6395921 Nominal Capacity, 41500 Efficiency: 13.2 SEER Heating System Type: Natural Gas Furnace Model: 59SUB100S21-22 Tradename: Carrier Manufacturer: CARRIER CORPORATION Description: Natural Gas or Propane Furnace Capacity: 93000 Efficiency: 92.1 AFUE � :\—\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM e:\ ...\Standard Pacific Fireside Plan 5058. rhv Wednesday, February 12, 2014, 11 AM Q21211 Calculation Mode: Htg. & c1g. Occurrences: Room Length: 1,3313 t System Number. Room Width. ft. Zone Number: 1 Area: 1,331.0 sq.ft. Supply Air: 162 CFM Ceiling Height: 9.8 ft. Supply Air Changes: 0.7 AC/hr Volume: 13,090,0 cu,ft. Req. Vent. Clg: 0 CFM Number of Registers 3 Actual Winter Vent.: 0 CFM Percent of Supply.. 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 10 CFM Actual Summer Infil,: 10 CFM SW-Wall-158I5-Ow-8 18.3 X 9,8 1802 0.047 18 681 0.1 0 20 SE-Wall-151315-0w-8 7,5 X 9.8 73.7 0,047 3.8 279 0"1 0 8 SW-Wall-158I5-Ow-816 X 9.8 1413 0.047 3.5 497 0.1 0 8 NW-Wall-158I5-Ow-818.3 X 9.8 1802 0.047 3,8 681 OA 0 20 NE- Wall - 15815 -Ow -8 8.5 X 9.8 83,6 0.047 3,8 316 0"1 0 9 SE -Wall- 15815 -Ow -8 24.3 X 9.8 223.2 0.047 3.6 807 0.1 0 17 SW-Wall-158I5-Ow-8 15.7 X 9,8 138 0.047 15 485 OA 0 8 NW- Wall - 15815 -Ow -8 7.3 X 9.8 721 0.047 3,8 272 0.1 0 8 SW-GIs-Atrium shgc-0.33 O%S 16 0.310 21.4 342 30,8 0 492 SE-Gls-Atrium shgc-0.33 O%S 16 0.310 21.4 342 30,8 0 492 SW- GIs - Atrium shge-0.33 O%S 16 0,310 21 A 342 30.8 0 492 Floor-21 A-32 I X 13313 1331.3 0.020 1.4 1,837 U 0 0 Subtotals for Structure: 6,881 0 1,574 Infil.: Win.: 9. 9, Sum.: 9.9 217 2.834 614 0.655 -215 142 Ductwork: 519 125 AED Excursion: 41 Room Totals: 8,014 -215 1,883 e:\ ...\Standard Pacific Fireside Plan 5058. rhv Wednesday, February 12, 2014, 11 AM Q21211 x` m t� 'C Loa ro t t _.._..._ _..__.._. . ! Calculation Mode: Htg. & c1g. Occurrences: 1 r Room Length: 200.6 ft, System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 201.0 sq.ft. Supply Air: 34 CFM Ceiling Height: 9.8 ft. Supply Air Changes: 1.0 A j Volume: 1,972.0 cu.ft. Req. Vent, Clg 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 °lam Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 2 CFM Actual Summer Infil.: 2 CFM NE- Wall - 15515 -Ow -8 11.3 X 9.8 111.4 0.047 3.8 421 0.1 0 12 SE- Wafl- 151315 -0w -8 13.3 X 9.8 115 0.047 3.5 398 0.0 0 5 s SE -GIs- Atrium shgc -0.33 O °IBS 16 0310 21.4 342 30.8 0 492 Floor-21 A -32 1 X 200.6 200.6 0.020 1.4 277 0.0 0 1 0 Subtotals for Structure: 1 0 509 Infil.: Win.: 2.1, Sum.: 2.1 46 2.823 130 0.651 -46 30 Ductwork: 109 56 AED Excursion. 19 People. 200 Iatter, 230 en /per. 1 200 230 Room Totals. 1,677 154 844 Y :l ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12,2014,11:15 AMC dw a :\ ...\ Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 1115 AM Calculation Mode: Htg. & c1g. Occurrences: I Room Length: 58.1 ft. System Number: I Room Width: 1.0 ft. Zone Number, I Area: 58.0 sq.ft. Supply Air: 14 CFM Ceiling Height: 9.8 ft. Supply Air Changes: 1.5 AC/hr Volume: 571.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers 1 Actual Winter Vent.: 0 CFM Percent of Supply. 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: I CFM Actual Summer Infil.: 1 CFM NE-Wall-1 5B1 5-Ow-8 11 X 9,8 108A 0.047 3,8 409 0"1 0 12 SE-Wall-1 5B1 5-Ow-8 2.5 X 9.8 24.6 0.047 3.8 93 0.1 0 3 Floor-21 A-32 1 X 58.1 5& 1 0.020 1�4 80 0�0 0 0 Subtotals for Structure: 582 0 15 Infil.: Win,- 1.2, Sum.: 1.2 25 2.816 71 0,674 -25 17 Ductwork: 45 2 AED Excursion: .. .. .. .... 1 '_ Room Totals: 698 -25 i 35 a :\ ...\ Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 1115 AM ""'�t� • • '"` � �" � �" �► �.� �" "'fir �: Y:\ .,. \Standard Pacific Fireside Plan 50 8.rhv Wednesday, February 12, 2014,11:15 AM ,, Calculation Mode: Ntg. & clg. Occurrences; 1 i Room Length 621.9 ft. System Number: 1 Room Width; 1.0 ft. Zone Number: 1 Area: 622.0 sq.ft. Supply Air: 69 CFM Ceiling Height; 9.8 ft, Supply Air Changes: 01 AC/hr Volume. 6 cu.ft. Req. Vent, CIg. 0 CFM Number of Registers: 1 Actual Winter Vent.. 0 CFM Percent of Supply.. 0 % Actual Summer Vent.. 0 CFM Percent of Supply: 0 % Actual Winter Infil.. 2 CFM Actual Summer Infil.. 2 CF 1 51 ,�?\^ r u,.� �3+�i�,'�,+ l �^: Y' ��. tS� U' •,�' �' Y ka.:" .1: ? t �w� ° 'i ' '�a \ \ \w� °� 'i \�'� �u;: '�` � \' � `F^ 1 � vsti NW- Wall -R11 Draped -9 41.8 X 9.8 411.2 0.051 3.6 1,483 0.0 0 16 SE- Wall -R11 Draped -9 19.8 X 9.8 194.9 0.051 3,6 703 0,0 0 8 NE- Wall -R11 Draped -9 0.8 X 9.8 82 0.051 3.6 29 0.0 0 0 Floor-21A-32 1 X 621.9 621.9 0.020 14 858 0.0 0 0 Subtotals for Structure. 3,073 0 24 Infil.. Win.. 2.2, Sum.. 2.2 49 2.829 139 0.651 -49 32 Ductwork. 223 4 I AED Excursion. 11 11 I'll, 1 I ; Roam Totals: 3,435 -49 61 , Y:\ .,. \Standard Pacific Fireside Plan 50 8.rhv Wednesday, February 12, 2014,11:15 AM ,, I - , i '$ 'ice Ao-'a�1 ��1 `.��,t�\'"ix'a 1�'.a" w�di�du: ( G \ t "`� . ..,A � j� }.•�j" L� k�w5 t u . , �i�� ��t** ` L � i. \ t � � � Calculation Made. Htg. & c1 g. Occurrences: 1 �t Room .length. 2483 ft. System Number. 1 s Room Width, 1.0 ft. Zane Number. 1 Area.. 248,0 sq.ft. Supply Air. 25 CFM Ceiling Height: 4.0 ft. Supply Air Changes:. 1.5 AC /hr I Volume:. 9910 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 % f Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 0 CFM [ Actual Summer Infil.: 0 CFM �\lUi�\}., \'.uS '`t: tkl 'r- i>"�� Vii. l�?,�.Y ri, `�`'dC`� '�` It �`�` v . v' Wun 1�1 }\ i�ra�l...'.}�.�;* tl��'r"i`1a•,u( 'l v "L\�i 1\ SW- Wall -R11 Draped -4 2,5 X 4 10 0.052 43 43 0.0 0 0 NW- Wall -R11 Draped -4 123 X 4 49.3 0.062 43 211 0.0 0 0 NE-Wall-RI 1 Draped -4 12.2 X 4 48.7 0.062 43 208 0,0 0 0 SF- Wall -R11 Draped -4 1 X 4 4 0.062 43 17 U 0 0 f NF- Wall -R11 Draped -4 8.7 X 4 34.7 0.062 43 148 0.0 0 0 SF- Wall -R11 Draped -4 11.3 X 4 45.3 0.062 4.3 194 0.0 0 0 Floor -21 A -32 1 248 . �. _...._ ._.,..,_ ._._. . �_ .�. _ ,_.... .,... ... .___e. ,.... .. . .__ ... _ _ . _...... Subtotals for Structure. 1,164 0 0 Infil.: Win.. 0,0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 81 0 Room 'totals: 1,245 0 0 — \Standard Pacific Fireside Plan 50 8.rhv Wednesday, February 12, 2014, 11:15 AM � --' D eta ile d Ro o m L oads Roo m 6 Ca sita Load Procedure . ....... .. calculation Mode: Htg. & c1 g. Occurrences: 1 Room Length: 271.2 ft. System Number: 1 Room Width: 1.0 ft. Zone Number.- I Area: 271.0 sq.ft, Supply Air: 107 CFM Ceiling Height: 9A ft. Supply Air Changes: 2.6 AC/hr Volume: 2,464,0 cu.ft. Req. Vent. Cig: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 21 CFM Actual Summer Infil.: 21 CFM NW-Wall-1 2F-Osw 11,6 X 9.1 107.4 0,065 4.5 482 0.7 0 79 NE-Wall-12F-Osw 12.2 X 9.1 90,5 0.065 4.5 406 0.7 0 66 SE-Wall-1 2F-Osw 1 X 9.1 9.1 0.065 4.5 41 0.7 0 7 NE-Wall-12F-Osw 8.7 X 91 68.7 0.065 4.5 308 0,7 0 50 SE-Wall-I 2F-Osw 11 2 X 9.1 81.4 0.065 4.5 365 03 0 60 SW-Wall- I 217-0sw 2.5 X 9.1 223 0.065 4.5 102 0.7 0 17 SE-Wall-1 2F-Osw 4.2 X 9.1 20.1 0.065 4,5 90 0.7 0 15 SE-Door-Door U-.20 2,7 X 6.7 17.8 0.200 13.8 246 4.4 0 78 1 NE-Gis-Atrium shgc-0.33 O%S 20 0.310 21.4 428 25.6 0 511 NE-Gis-Atrium shgo-0.33 O%S 10 0.310 21.4 214 25,6 0 256 SE -GIs- Atrium shgc-0.33 O%S 20 0.310 21.4 428 30.8 0 615 UP-Ceil-16B-38 271.2 X 1 271 0.026 1.8 487 1,2 0 324 Subtotals for Structure: 3,597 0 2,078 Infil.: Win,-. 21.4, Sum.: 21.4 468 2.833 1,325 0.656 -463 307 Ductwork: 341 174 AED Excursion: 57 Room Totals: 5,263 -463 2,617 Y Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM k f (:\..,\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM "Room Loads - Room 7 - Casita Bath Load Pro Calculation Mode: Htg� & c1g. Occurrences: I Room Length: 9,0 ft. System Number I Room Width 6.2 ft Zone Number: I Area: 56.0 sq.ft. Supply Air: 13 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 1�6 AC/hr Volume: 504O cu,ft. Req. Vent. Clg: 0 CFM Number of Registers: I Actual Winter Vent.: 0 CFM ercent • u•• 0 % Actual Summer Vent.: 0 CFM Percent of Supply. 0 % Actual Winter lnfil. 3 CFM Actual Summer Infil.: 3 CFM NW-Gis-Atrium shgc-0.33 O%S 6.2 0,310 21 A 134 25�6 0 160 UP-Ceil- I 6B-38 55.5 X 1 55.5 0.026 1,8 100 1,2 0 • Subtotals for Structure: 457 0 263 Infil.: Win.: 2.6, Sum.: 2.6 56 2.838 159 0,660 -56 37 Ductwork: 43 22 AED Excursion: 7 Room Totals: 659 -56 329 k f (:\..,\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM Room Loads - Room 8 - Laundry, Load _Detailed Calculation Mode: Htg. & c1g. Occurrences: I Room Length: 5.2 ft. System Number: I Room Width: 83 ft. Zone Number 1 Area: 43.0 sq,ft, Supply Air: 25 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 18 AC/hr Volume 391.0 c0t, Req. Vent. Clg: 0 CFM I Number of Registers: 1 Actual Winter Vent,: 0 CFM Runout Air: 25 CFM Percent of Supply,: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 283 ft,/min. Percent of Supply 0 % Runout Air Velocity: 283 ft./min, Actual Winter Infil.: 0 CFM Actual Loss: 0.076 in.wg./100 ft. Actual Summer Infil.: 0 CFM 11 = 1`11 � 1`' -`111 UP-Ceil- I 6B-38 41 X 1 43.1 0.026 1.8 t 77 12 0 51 Subtotals for Structure, 77 0 51 Infil.: Win,: 0,0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 5 40 AD Excursion: 13 Equipment:, 0 t10 Room Totals: 82 0 604 (. Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM Y.1.,, \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM .� D Calculation Mode. Htg. & clg. Occurrences: 1 Room length. 5.2 ft. System Number. 1 Room Width: 52 ft. Zane Number. 1 Area. 27.0 sq.ft. Supply Air. 1 CFM Ceiling Height: 9A ft. Supply Air Changes: 0.4 AC /hr Volume. 2410 cu.ft. Req. Vent. Clg: 0 CFM } Number of Registers: 1 actual Winter Vent... 0 CM Runout Air. 1 CM Percent of Supply.: 0 °lam Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 16 ft. /min. Percent of Supply. 0 % Runout Air Velocity: 16 ft. /min. Actual Winter Infil.: 0 CFM Actual loss: 0,000 in.wg. /100 ft. Actual Summer Infil.. 0 CFM ��„b � � t W y � [ YLL�:�`�, y �� �` R \ P'.. �1t tb , ' ^ r� �a1t i, ` w >� � . � Ya'�ti � �`�.'�a� 4 , i lkall` t `tt t+.ti�„"^i 't '3v�i����ttlik i wl" ' UP- 26.7 X 1 .$i: 26.7 ww 0.026 1.8 48 1.2 0 32 Subtotals for Structure. 48 0 32 ! Infil.. Win.. 0.0, Sum.: 0.0 0 0 0 0 0 0 1 Ductwork. 3 2 AEC} Excursion, 1 Room Totals: 51 0 35 ` Y.1.,, \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM .� D I I Detailed Room Loads - Room 1 0 - Mstr WIC_2 q�qgq I _Lpqd_ Calculation Mode: Htg. & c1g. Occurrences: I Room Length: 9.0 ft. System Number: I Room Width: 10,0 ft, Zone Number: I Area: 90.0 sq.ft. Supply Air: 18 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 1. 3 AC/hr Volume: 818.0 cu.ft. Req. Vent, Clg * 0 CFM Number of Registers: I Actual Winter Vent,: 0 CFM Percent of Supply., 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 4 CFM Actual Summer Infil.: 4 CFM 71 71" NW-Wall-12F-Osw 10 X 9A 90,8 0.065 4.5 407 0.7 0 6 UP -Cell- 1 613 -38 90 X 1 90 0.026 1.8 161 1.2 0 to Subtotals for Structure: 568 0 175 Infil.: Win.: 4.1, Sum.: 4.1 91 2.830 257 0.661 -90 60 Ductwork: 57 17 1 AFC) Excursion: 6 Room Totals: 882 -90 258 1 i :\—\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 1 2, 2014,11 AM Room Totals 1,769 -138 914 ----------- -- — ---- --------- Y, Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014, 11:15 AM Detailed Room Loads - Room 1 1 Master, Bath Occurrences: 1 System Number: I Zone Number: I Supply Air: 37 CFM Ceiling Height: 9A ft. Supply Air Changes. 1A AC/hr Volume: 2,055.0 cu.ft. Req, Vent. Clg: 0 CFM Number of Registers: Actual Winter Vent.: 0 OFM Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: • % Actual Winter Infil.: • CFM Actual Summer Infil,: 6 CFM NW-Gls-Atrium shgc-0.33 O%S • 0310 21 4 342 25.6 0 409 UP-Ceil-1 6113-38 2014 X 1 2014 ............. . .... ...... . . .. ..... ..... . ........... . .. . .. .... .. .. O�026 1�8 365 12 0 243 Subtotals for Structure: 1,260 • 742 Infil.: Win.: 6.4, SLM: 6.4 139 2.831 394 0.654 -138 91 Ductwork: 115 61 AED Excursion: 20 Room Totals 1,769 -138 914 ----------- -- — ---- --------- Y, Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014, 11:15 AM 1Ftr Y:\ ... \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM dzz IV Calculation Mode: Htg. & c1g. Occurrences: Room Length: 5.8 ft. System Number: Room Width: 3.5 ft. Zone Number: I Area: 20.O sq.ft. Supply Air: 10 CFM Ceiling Height: 9,1 ft. Supply Air Changes: 12 AC/hr Volume: 185,0 cu ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Percent of Supply. - 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 1 CFM Actual Summer Infil.: I CFM NW-Wall-12F-Osw 3.5 X 9.1 25.8 0,065 4,5 116 0,7 0 19 NW -GIs- Atrium shgc-0.33 O%S 6 0.310 21.4 128 25.5 0 153 UP -Cell- 1613 -38 204 X 1 20.4 0.026 1.8 37 12 0 24 1 Subtotals for Structure: 281 0 196 Infil.: Win,: 1 .5, Sum,: 1.5 32 2.832 90 0.661 -31 21 Ductwork. 26 16 AED Excursion ---- --- .... . .. ....... ............. . . . .... ... ... .... .... . . .. ..... ....... Room Totals: 397 -31 238 Y:\ ... \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM dzz IV Room Length: 5.8 ft. System Number: 1 Room Width: 9.0 ft. Zone Number: 1 Area: 52.0 sq.ft. Supply Air: 15 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 1.9 AC/hr Volume: 477.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM } Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 4 CF Actual Summer I fil.: 4 CFM NW°Wall- 12F-Osw 9 X 91 81.7 0.065 4,5 367 0.7 0 60 UP- Cei1- 16S -38 52.5 X 1 52.5 0.026 1.8 94 1.2 0 63_ Subtotals for Structure: 461 0 123 Infil.: Win.: 3.7, Sum.: 3.7 82 2.827 231 0.661 -81 54 Ductwork: 48 13 s AED Excursion: 4 Room Totals: 740 -81 194 , Y :l ... \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM ---------- 1 Detai ed Room Loads - Room 14 - Master Bedroom very Load Proce Calculation Mode: Htg, & c1g. Occurrences: I Room Length: 300.6 t System Number: I Room Width: I'0 ft. Zone Number: 1 Area: 301.0 sqft Supply Air: 142 CFM Ceiling Height: 9,4 t Supply Air Changes 10 AC/hr Volume: 2,830.0 cu.ft. Req. Vent. CIg 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 17 CFM Actual Summer Infil.: 17 CFM � �cx�����z�'���tyu \ aa``�����:. � � . �z \ " nu, \l�, � 'Y1"�"11�Y zu. SW-Wall-12F-Osw 16 X 9.1 95.3 0.065 4.5 427 03 0 7 NW-Wall-12F-Osw 16.7 X 9,1 1314 0,065 4.5 589 0.7 0 9 SF- Wall- 12F -Ow 7.5 X 9.1 46.7 0.065 4.5 210 0.7 0 34 SE-Door-Door U-.20 2.7 X 8 21.4 0.200 118 295 4.4 0 94 SW-Gis-Atrium shgc-0.33 O%S 15 0.310 21.4 321 301 0 46 SW-Gis-Atrium shgc-0.33 O%S 20 0.310 21.4 428 30.8 0 615 SW -GIs- Atrium shgc-0,33 O%S 15 0.310 21.4 321 30.7 0 461 1 NW- GIs - Atrium shgc-0.33 O%S 10 0.310 21.4 214 25.6 0 256 1 NW-Gis-Atrium shgc-0-33 O%S 10 0310 21.4 214 25.6 0 256 1 1 UP-Ceil-I 6B-38 300.6 X 1 300.6 0.026 1.8 539 1,2 0 359 Subtotals for Structure: 3,558 0 2,702 Infil.: Win.: 16.7, Sum.: 16.7 365 2.832 1,033 0.658 -361 240 Ductwork: 318 234 AED Excursion 76 People: 20 lat 2130, s 1 20 1 0 , 11 11 111111 Room Totals: 4,909 -161 3,480 Y:\...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM Roo ec rr Load Proce r _: Calculation Mode. Ntg. & cig. Occurrences: 1 Room Length. 3342 ft. System Number. 1 E Room Width: 1.0 ft. Zone Number. 1 Area.. 334.0 sq.ft. Supply Air. 169 CFM Ceiling Height: 16.3 ft. Supply Air Changes: 1.6 AC/hr Volume: 6,4310 cu.ft. Req. Vent. Cl g: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM I Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 °lam Actual Winter Infil.: 21 CFM Actual Summer Infil.: 21 CFM 4 I)w a \,SAM t au� gfik 1 SW-Wall-12F-Osw 13.3 X 102 292.9 0.065 4.5 1,313 03 0 215 I NW- Wall- 12F -Osw 12.5 X 9.1 113.5 0.065 4.5 509 03 0 8 SW•Gis- Atrium shgc -0.33 O %S 15 0.310 21.4 321 30.7 0 461 SW- GIs - Atrium shgc -0.33 O °IBS 15 0.310 21.4 321 30.7 0 461 W -GIs- Atrium shgc -0.33 O %S 30 0.310 21.4 642 30.7 0 922 UP- Ceil- 16R -38 334.2 X 1 334.2 0.026 _.._. _, ,. .. _. ....._ _...... w _ _... 1.8 600 1.2 - ... _... _ .. _. _ _._. _.. _. 0 a _.. _ 400 ...r._,. Subtotals for Structure: 3,706 0 2,542 Infil.: Win.: 213, Sum.: 21.3 466 2.833 1,321 0.656 -462 306 Ductwork. 348 276 i AEA? Excursion. 91 , People: 200 lat?per, 230 sentper: 1 200 230 Equipment; 0 700 Room Totals. 5,375 -262 4,145 r;\ ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11 :15 AM c.# F -1--l-I . I..--l.1.1-----.,."--1--l'Il-11-1----I ---------- - - ---- ------- Detailed Room Loads - Room 16 - NooklKitchen( Load Pro cr Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 466.6 It. System Number: I Room Width, 1.0 ft. Zone Number: 1 Area: 467.0 sq,ft. Supply Air: 235 CFM Ceiling Height 10.2 ft. Supply Air Changes: 3.0 AC/hr Volume: 4,744,0 cu.ft. Req. Vent, Cl. 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Percent of Supply. - 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil. 25 CFM Actual Summer Infil.: 25 CFM SW-Wall-12F-Osw 15.7 X 102 109.4 0.065 4.5 490 0,7 0 80 NW-Wall-12F-Osw 7.3 X 102 26.5 0.065 4.5 119 0.7 0 19 SE- Wall- 12I = -0s 30.5 X 10.2 2902 0.065 4.5 1,301 0.7 0 213 SW -GIs- Atrium shgc-0-33 O%S 15 0.310 21.4 321 30.7 0 461 SW-GIs-Atrium she -0.33 O%S 20 0.310 21.4 428 30,8 0 615 SW-Gis-Atrium shgc-0.33 O%S 15 0..310 21.4 321 303 0 461 NW-Gis-Atrium shgc-0.33 O%S 48 0.310 21.4 1,027 25.6 0 1,227 SE-Gls-Atrium Oqq 20 0,310 ..... . .. .. ... .. 21.4 428 30.8 0 615 Subtotals for Structure: 4,435 0 3,691 Infil.: Win.: 24.8, Sum.: 24.8 544 2.832 1,541 0.656 -539 357 Ductwork: 414 383 AED Excursion: 126 Equipment: 0 1,200 Room Totals: 6,390 ------------ - -539 5,757 lI e:\ .,,\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM ( Y:\...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM, Vi 1 Calculation Mode: Htg. & c1g, Occurrences: Room Length: 74.1 ft. System Number: Room Width: 1.0 ft. Zone Number: Area: 74,0 sq.ft. Supply Air: 42 CFM Ceiling Height: 102 ft. Supply Air Changes: 33 AC/hr Volume: 7510 cu,ft, Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 9 CFM Actual Summer Infil.: 9 CFM NE-Wall-12F-Osw 11.3 X 102 974 0.065 4.5 437 0,7 0 72 I SF- Wall -1F -Os w 7.2 X 10.2 60,9 0.065 4.5 273 01 0 45 NE-Door-Garage Entry 2,7 X 6.7 17.8 0.357 24,6 439 7.9 0 140 SF -GIs- Atrium sh e -4.33 O%S 12 0,310 21.4 257 30,8 0 369 1 Subtotals for Structure: 1,406 0 626 Infil.: Win.: 8.6, Sum,: 8.6 188 2.833 533 0,659 -186 124 1 Ductwork: 134 55 AED Excursion":, Room Totals: 2,073 -186 823 Y:\...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AM, Vi 1 Room 18 - Din Detailed Room Loads Load Procedu!�qj_ - --------------- ------- ........... Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 227.4 ft, System Number. 1 Room Width: 1.0 ft. Zone Number. I Area: 227,0 sq.ft. Supply Air: 35 CFM Ceiling Height: 1 02 ft, Supply Air Changes 0.9 AC/hr Volume: 2,311.0 cu.ft. Req. Vent. Cig: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 % Actual Summer Vent- 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 8 CFM Actual Summer Infil.: 8 CFM 3 j +`,:. . ��� C jA„ ��y+'di�� �'}��'S�1`W,,,,_`,Ka�� §����� � 1 �1P�1 l}� � M +M ��w�4�u, `l '±e . '� � 3 NE-Wall-12F-0sw 15 X 10.2 132.6 0.065 4.5 594 03 0 97 SE-Wall-I 2F-Osw 2.5 X 1 02 25.4 0,065 4.5 114 0.7 0 19 NF -GIs-Atrium "shgc-0.33 O%S 20 0.310 21.4 428 25.6 0 511 Subtotals for Structure: 1,136 0 627 Infil.: Win.: 8.1, Sum.: 8.1 178 2.832 504 0.657 -176 117 Ductwork: 114 54 AFC? Excursion: ... ........... . . . ..... ------ 18 1 Room Totals: 1,754 -176 i 816 . ......... . ..... Y:\ ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 AMC [_Detailed Room Loads - Room 19 - /I "( yqr,?g Load Prqqqc( Calculation Mode, Htg. & c1g. Occurrences: 1 Room Length: 2713 ft. System Number: 1 Room Width: l'o ft. Zone Number: 1 Area: 271.0 sq.ft. Supply Air: 67 CFM Ceiling Height: 15.0 ft. Supply Air Changes: 1.0 AC/hr Volume: 4,070.0 cu-ft- Req. Vent. Cig: 0 CFM Number of Registers.* 1 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply 0 % Actual Winter Infil.: 12 CFM Actual Summer Infil.: 12 CFM SE-Wall-12F-Osw 15.8 X 10.2 143 0.065 4.5 641 O.7 0 105 NE-Wall-12F-Osw 5.3 X 192 66.6 0.065 4.5 299 01 0 49 i NE-Door-Front Entry 3 X 8 24 0A61 11.1 267 15 0 85 SE- GIs - Atrium shgc-0.33 O%S 18 0.310 21.4 385 30.7 0 553 NE -GIs- Atrium shgc-0,33 O%S 12 0.310 21.4 257 25.6 0 307 UP-Ceil-1613-38 189.5 X 1 189.5 0.026 1 8 340 1.2 .. . . ... ...... . .. . ........... .. 0 227 Subtotals for Structure: 2,189 0 1,326 Infil.: Win.: 12.0, Sum.: 12.0 264 2,834 747 0.656 -261 173 Ductwork: 203 log AED Excursion: 36 Room Totals: 3,139 -261 1,645 i t Y:\ ... \Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014, 11:15 AM I Detailed Room Loads - Room 20 - Bedroom 3 (Ayq� e Load Procedure, L ------ ----- - x Calculation Mode: Htg. & clg. Occurrences: 1 Room Length 232.4 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 232.0 sq.ft. Supply Air 91 CFM Ceiling Height: 91 ft. Supply Air Changes'. 2.6 AC/hr Volume: 2,111.0 cu.f t, Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Percent of Supply.: 0 % Actual Summer Vent- 0 CFM Percent of Supply: 0 % Actual Winter Infil. 16 CFM Actual Summer Infil.: 16 CFM SW-Wall-12F-0sw 15.7 X 9.1 117.3 0.065 4,5 526 0.7 0 86 1 NW-Wall-12F-0sw 7.6 X 9.1 68.9 0.065 4.5 309 01 0 51 SE-Wall-12F-0sw 14.8 X 9.1 124.7 0.065 4,5 559 0.7 0 92 SW -GIs- Atrium shgc-0.33 O%S 25 0.310 21.4 535 30.7 0 768 SE- GIs - Atrium she -0.33 O%S 10 0,310 21.4 214 30,7 0 307 UP-Ceil-1613-38 232.4 X 1 232.4 0.026 - ---- - ------------ . . ..... ........ . .. .. . ... . . ...... ..... . . . . .... ..... .... ...... ... 1,8 417 1.2 0 278 Subtotals for Structure: 2,560 0 1,582 Infil,: Win.: 15.8, Sum.: 15.8 346 2.834 980 0.656 -343 227 Ductwork: 245 149 AED Excursion: 49 People: 200,lat/per,, _23,0 sen/per: .............. .. 200 230 Room Totals: 3,785 -143 2,237 1 Y:\ . ,\Standard Pacific Fireside Plan 5058. rhv Wednesday, February 12, 2014, 11 :15 AM i [ # Lai m 21 - Bath 2 _ qge Load Pro Calculation Mode. Htg. & clg. Occurrences: 1 Room Length: 113 ft. System Number: i Roams Width: 5.2 ft. Zone Number: 1 Area: 59.0 sg.ft. Supply Air: 10 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 1.1 AC/ } ` Volume: 532.0 cu.ft. Rest. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CM Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 2 CFM Actual Summer Infil.: 2 CM ,;Fi"`3ySi'i,�t�. lh �1A m+. +�' ' Ya�A' ,,�"'`�.a q' � , KK4 a�k A..4 �" i.,:?k,x•_ 3 .,. �� x ,1�`. ,'� t :�i\ ,.. ' ' 1 i.';:, "'w) t t✓t `t �. ' n� .0 �a Y }, � t� � � � �'� � aC �� �, t '',., ,,u ,il'St")A wt� ° .• Sl, �b t \ .. \.. E 1 1� SE - Well- 12F -Osw 5.2 X 9.1 46.9 .�: s .t, Ci 0.065 4.5 211 0.7 ,� 0 34 UP -Cell- 168 -38 58.6 X 1 58.6 0.026 1.8 105 1.2 0 70 ! Subtotals for Structure: 316 0 104 Infil.: Win.: 2.1, Sum.: 2.1 47 2.833 133 0.660 -47 31 Ductwork: 31 10 AED Excursion: 11 I'll 3 F Roomy Totals: 480 -47 148 € l i 7 I t k I w Y:\ ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM - -- - ---------- - - ----- l.---,.---,--,---,--,---,----..-.-----,-,.--,--,----------,--------.----,.---.,-,------., I Detailed Room Loads - Room 22 - Bedroom 2,(4yqrqge Prog L Calculation Mode: Htg. & c1g. Occurrences: Room Length: 11.3 ft. System Number: Room Width: 17.8 ft. Zone Number: 1 Area: 202.0 sq.ft. Supply Air: 69 CFM Ceiling Height: 9.1 ft. Supply Air Changes. 2.3 AC/hr Volume: 1,835.0 cu.ft. Req. Vent Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Percent of Supply.: Actual Summer Vent.: 0 0 % CFM Percent of Supply: 0 % Actual Winter Infil.: 12 CFM Actual Summer Infil.: 12 CFM 7 ' NE-Wall- 1 2F-Osw 11.3 X 9.1 86,9 0.065 4.5 390 0.7 0 64 SE-Wall-I 2F-Osw 17.8 X 9.1 151,9 0.065 4.5 681 01 0 112 NE-Gis-Atrium shgc-0.33 O%S 16 0.310 21.4 342 25.6 0 409 SE -GIs- Atrium shgc-0.33 O%S 10 0.310 21.4 214 30.7 0 307 UP-Cefl-1613-38 202.1 X 1 202.1 0.026 ­­­­­",',"",", ­11111l 11 --- -------- 1.8 363 1.2 0 242 Subtotals for Structure: 1,990 0 1,134 Infil.: Win.: 12.1, Sum.: 12.1 265 2.833 750 0.657 -262 174 Ductwork: 190 112 AED Excursion: 37 Peqple p lat/ er 230 senIpor: 1 200 230 1 1 1 ,200 Room Totals: 2,930 -62 1,687 YA ...0 Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014, 11:15 A<i.' i t i i i l i I i I E e:\...\Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014,11:15 A Calculation Movie: Ht g. & clg. Occurrences: 1 f Room Length: 194.6 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area.: 195.0 sq.ft, Supply Air: 65 CFM Ceiling Height: 9,1 ft, Supply Air Changes: 2.2 AC/hr Volume: 1,768.0 cu.ft. Req. Vent, Cig: 0 CFM Number of Registers: 2 Actual Winter Vent,: 0 CFM } Percent of Supply.: 0 % Actual Summer Vent.: 0 CFM Percent of Supply: 0 % Actual Winter Infil.: 8 CFM Actual Summer Infil.: 8 CFM € NW- Wall- 12F -Osw 1 X 9.1 9.1 0.065 4.5 41 01 0 7 NF- Wall- 12F -Osw 15.2 X 9.1 107.7 0.065 4.5 4€38 03 0 79 i I SF- Wall- 12F -Osw 3.5 X 9,1 31.8 0.065 4,5 143 0,7 0 2 ` NF- Cis - Atrium shgc -0.33 O %S 15 0.310 21.4 321 25,6 0 384 NE -Cis- Atrium hgc -0.33 O °IBS 15 0.310 21.4 321 25.6 0 384 UP®Ceil- 1613 -3 194.6 X 1 194.6 0.026 1.8 349 12 0 233 Floor- 20P -30 1 X 15.2 .._.... ... _. 15.2 0.035 m ..w... .... , __ .. _ .._ 2,4 37 ...,_.. 0.2 0 i Subtotals for Structure. 1,695 0 1,113 Infil.: Win.: 8.2, Sum.: 8.2 179 2.833 506 0.655 -177 117 Ductwork: 153 107 1 AED Excursion: 35 People: 200 lattper, 230 seglper: 1 200 230 Room Totals, 2,354 23 1,602 i t i i i l i I i I E e:\...\Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014,11:15 A J U, Detailed Room Loads - Room 24 P��p�Myel�g�d Procedure) WE IN . .. . ............ Calculati on Mae: Htg. & c1g. Occurrences: 1 Room Length: 210,0 ft, System Number: I Room Width: 10 ft. Zone Number: I Area: 210O sq.ft, Supply Air: 50 CFM Ceiling Height: 9A ft. Supply Air Changes: 1,6 AC/hr Volume: 1,907,0 cuft. Req. Vent, Cg: 0 CFMI Number of Registers: Actual Winter Vent, 0 CFM Percent of Supply.: 0 % Actual Summer Vent, - 0 CFM Percent of Supply: 0 % Actual Winter lnfil,: 11 CFM Actual Summer Il 99 27 NW-Gis-Atrium shgc-0.33 O%S 4 0.310 21.4 86 25.5 0 I. I NW-Gis-Atrium shgc-0.33 O%S 4 0.310 21.4 86 25,5 0 102 NW-Gls-Atrium shgc-0.33 O%S 4 0.310 21.4 86 25,5 0 102 LIP-Ceil-16B-38 210 X 1 210 --- -------- 0.026 1.8 377 ...... .. ... .. 12 0 251 Subtotals for Structure: 1,647 0 723 1 Ill Win.: 10.8, Sum. 10,8 238 2832 673 0,657 -235 156 1 Ductwork: 161 64 A Excursion: PI i Roorn • 64 Y:\ ..,\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 AM I Rec Room 1,331 8,014 162 6,6,6 - 1,883 -215 105 162 2 Bedroom 4 201 1,677 34 6 - 844 154 47 34 3 Batty 4 58 698 14 4 m 35 -25 2 14 4 Mech 622 3,435 69 6 - 61 -49 3 69 5 Crawl Space 248 1,245 25 4 - 0 0 0 25 6 Casita 271 5,263 106 7, - 2,617 -463 146 107 7 Casita Bath 56 659 13 4 _ 329 -56 18 13 8 laundry 43 82 2 1 1-4 283 604 0 34 9 Pwdr 27 51 1 1 1-4 16 35 0 2 1 10 Mstr WIC 2 90 882 18 4 - 258 -90 14 18 11 Master Bath 226 1,769 36 6 914 -138 51 37 12 W/C 20 397 8 4 - 238 - 1 13 10 13 Mstr WIG 52 740 15 4 - 194 -81 11 15 14 Master Bedroom 301 4,909 99 7,7 - 3,480 -161 194 142 15 great boom 334 5,375 108 6,6,6 - 4,145 -262 230 169 16 Nook/Kitchen 467 6,390 129 7,7,7 _ 5,757 -539 320 235 17 Mud Roam 74 2,073 42 6 823 -186 46 42 18 Dining /Opt Study 227 1,754 35 6 - 816 -176 45 35 19 Foyer /Hall 271 3,139 63 7 - 1,645 -261 91 67 20 Bedroom 3 232 3,785 76 7,7 2,237 -143 124 91 21 Bath 2 59 480 10 5 - 148 -47 8 10 22 Bedroom 2 202 2,930 59 7,7 - 1,687 -62 94 69 23 Bonus/ Opt. BR4 195 2,354 47 7,7 - 1,602 23 89 65 24 Bridge . 210 2,481 50 7 - 964 -235 54 50 Humidification 3 }155 Duct latent -96 S stem 1 total 5,817 63,736 1,222 31,316 -3,139 1,742 1,279 System 1 Main Trunk Size: 25x12 in. Velocity: 600 ft. /min Loss per 100 ft,; 0.028 in,wg Duct size results above are from Manual D Ductsize _ .. indicated . See the Manual D Ductsize report for duct velocities and other data. I Indicates duct sized with Rhvac's built-in duct sizing rather than with Manual D Ductsize. ' s � • r • °�• ♦ • M i •• Actual: 3.46 100%/0% 41,500 0 41,500 Heqtina System Goolin 5 stem Type: Natural Gas Furnace Standard Air Conditioner Model.: 59SC2B100S21 - -22 CA13NA042 .... (A,B) Indoor Model: CNPV *4821 AL * +TDR Brand: Carrier CARRIER AIR CONDITIONING Description: Natural Gas or Propane Furnace Efficiency: 92.1 AFUE 13.2 SEER Sound; Capacity; 93000 41500 Sensible Capacity; n/a 41,500 Btuh Latent Capacity: n/a 0 Btuh AHRI Reference No.: n/a 6395921 Y:\ ... \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014,11:15 A MC 7 , Lo ad Sum Indicates highest value of all rotations. Y:\ ... \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 A ,U�� -------------- All rotation degree values in this report are clockwise with respect to the project's original orientation, Building orientation as entered (zero degrees rotation): Front door faces Northeast At least one system with its System Air Type input set to Fixed was changed to Auto during the building rotation, If you ge this behavior uncheck the option on the General tab of the Select Reports dialog called "Always u ir Type for Building Rotation Report." System 1: Zone 1: 1 Rec Room *162 162 162 162 162 162 162 162 6,6,6 2 Bedroom 4 47 35 47 *52 41 34 41 51 6 3 Bath 4 *14 14 14 14 14 14 14 14 4 4 Mech *69 69 6• 6• 69 69 69 69 6 5 Crawl Space *25 25 25 25 25 25 25 25 4 ♦ Casita 145 151 *156 137 146 138 136 124 7 Casita Bath 18 13 18 *22 20 15 20 22 4 8 Laundry 34 *34 34 33 33 33 33 33 1-4 9 Pwdr 10 Mstr WIC 2 *18 18 18 18 18 18 18 18 4 11 Master Bath 51 37 51 *60 55 43 55 60 6 12 W/C 13 8 13 *17 15 10 15 17 4 13 Mstr WIC *15 15 15 15 15 15 15 15 4 14 Master Bedroom 193 194 178 145 180 *197 195 165 7,7 1 15 Great Room 230 *253 212 158 207 245 225 181 6,66 16 Nook/Kitchen 320 282 306 295 307 285 *322 314 7,7:7 17 Mud Room 46 42 46 *49 42 42 42 4• 6 18 Dining/Opt Study 45 *59 52 36 51 57 44 35 6 19 Foyer/Hall 91 86 *96 91 88 76 84 86 7 20 Bedroom 3 124 *126 117 97 111 118 119 107 7,7 21 Bath 2 *10 10 10 10 10 10 10 10 5 22 Bedroom 2 94 97 *99 89 94 91 89 82 7,7 1 23 Bonus/ Opt. BR4 8• *109 99 74 9• 10• 87 62 7,7 24 Bridge 54 50 54 *61 56 50 56 61 7 Indicates highest CFM of all rotations. I S 0 0 Northeast *1,741 *31,312 *-3,139 450 East 1,711 ♦ 30,770 -3,139 256 90 Southeast 1,714 30,817 -3,139 2.57 135 South 1,525 27,428 -3,139 229 180 Southwest 1,668 29,986 -3,139 2,50 225 West 1,656 29,769 -3,139 2.48 270 c' Northwest 1,699 30,550 -3,139 255 315' North 1,566 28,161 -3,139 2— Indicates highest value of all rotations. Y:\ ... \Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11:15 A ,U�� Rotation Building Rotation Tonnage I I e:\ ...\Standard Pacific Fireside Plan 5058,rhv Wednesday, February 12, 2014, 11:15 AMC Northeast East Southeast South Southwest West Northwest North Direction Front door Faces Buildinq Net Tonnage ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11.15 AM ... .... ... ... AO LLC ' �Ns 6 --------- - --- - ---------- Building Rotation Hourly Net Gain I 36, 000 ....................................................................... ........................ It 35,000 ...... 34,000 ............ fir: a 33,000t ...... 32,000' ....... — ...... 30,000 1 4. 29,000 28,0001 .... 27,00011111111 26,000t'- ........ — ......... — ..... 25,000 24,000 23,000 ......... 22,000 21,000 ------- 8 am 5 a 10 am 11 am 12 pm I pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm Time of Day Front door faces Northeast Front door faces East Front door faces Southeast Front door faces South Front door faces Southwest Front door f aces West Front door faces Northwest Front door faces North ...\Standard Pacific Fireside Plan 5058.rhv Wednesday, February 12, 2014, 11.15 AM City of W3.6atR I d C ,,,�g COMMUNny DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303,235.2846 F: 301235,2857 March 20, 2014 OFFICIAL ADDRESS NOTIFICA Z2IR!EAjMNMP CODE CORRECTION NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: PROPERTY OWNER(S): Standard PaciFic of Colorado Inc. A Delaware Ca ration OLD ADDRESS: None '90 abor Cr. Wheat Ri d e Co '0033 '0 NEW ADDRESS: 3 "0 't'ab � or Ct. 80033 Block 1_ Lo t25 3870 ab I or Ct. 80033 033 3 60 1, ab 8 or Ct Ile t Ri e C W 0�810033 80033 3 5 Ta b or 8 0 T or Cr. Ct W heat R i C e 081 Blac o 'oc t 2 8 Block 1 -Lor 6 3801 Taft Ct. Wheat Rtd e C{ 3 3830 T abor Ct. Tab block l _ I of 3819 `Taft Ct, Wheat I2id e CC) 3 Black 1 Lor 9 3829 Taff Ct. Wheat Rzd CC 3 Black t -Lot 10 3839 "Taft Ct. Wear Rid e CC? 33 Stock l _Lot 11 384 Tafr Ct. Wheat Rid e C) 33 Black 1 -Lor 12 38E9 Tafil Ct. Wheat laid >e C( 33 33 Block I Lot t4 3889 Taft Ct. Wheat Rid e CCU 33 'oc "o' '90 abor Cr. Wheat Ri d e Co '0033 '0 Block I - Lot 4 3 "0 't'ab � or Ct. W heat: e R id 80033 Block 1_ Lo t25 3870 ab I or Ct. Wheat Ri e 0 80033 C B l ack 1 Lot 26 3 60 1, ab 8 or Ct Ile t Ri e C W 0�810033 S to c k Lot .1 1 7 3 5 Ta b or 8 0 T or Cr. Ct W heat R i C e 081 Blac o 'oc t 2 8 384 Ta b 0 or Ct' t R ea 80 0 0033 d e �Q� : Mac k 2 I -ot 9 3830 T abor Ct. Tab i Co hea R �e 33 �( 8 � �ock I Lot 30 38 0 or Ct Wheat Co e R id 80�033 3 Black 2 - Ilot 3 383E `Taft Ct. Wheat. Rid e CCU 80033 Black 2 - Lat 4 3848 Taft Ct. Wheat Rid e fC} 3 3 33 WWWA-Wheatridgexo.us I 1] IM1 4 JIM I I I 101 (Block l,ot 1 2 3871 Tabor Q. Wheat Rid (Block 2 – Lot 13) 3861 Tabor Ct.,Wheat Ridge, co 8o033 Block 2 -• -Lot 14 3851 Taber Ct. Wheat Rid e CC) 80033 (Block 2 -.- Lot 15113841 Tabor Ct,,Wheat Ridg cO 80033 fRIA01- I – T tit I Al 'A R I I 'rnl nr Of 1X71-4 DA,.- f^t onlill SUIRDIVISION: Doud Overlook Subdivision aka Fireside at Youn field Subdivision LOT(S): KEY: SECTION: — JEFFERSON COUNTY RECEPTION #: 2013143668 9mmmusm NOTES: This is a courtesy notification, AUTHORIZED BY. DATE: JUL-11timu NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: DATE: R69W 601 ALUM. PPE W/ 3 -1/4 GRASS CAR EO STAMP LS 13212' N RANK 8O% PONT 14109 N-708326.7466 E- 1025512566 T35, P.2' I I I I 1 I i I I I I I� i� 1 I, M la IY� IW I I LOT 11 3819 0710 38M P p TV s s O 11858 11842 11828 NEST 39TH PLACE 0 2 1871 11851 RP 11831 G 2 11811 • 0 0 o s 398 H.O.A. C 3881 LOT 7 LOT 12 3884 3871 LOT 6 LANDSCAPING 3872 LOT 13 3881 LOT 5 C 3550 LOT 14 I 3851 3821 LOT 4 3848 LOT 15 3841 LOT 3 3836 1 <\ 1 0 LOT 22 11810 TRACT 8 E. 1/4 CORO" SEC. 20 T35, R69W 6TH P.Y. S AIW. i'Pf W/ 3 !BASS CAP l STAIIREEI ,313=13- N RAHOE E01 05310 ADDRESS PLAT PONT 14209 11212' N 9 RA" 0.1 a•0 DOUD OVERLOOK SUBDIVISION FILING NO. 2 BEING A REPLAT OF A PORTION OF DOUD OVERLOOK SUBDIVISION, --� LOCATED IN THE WEST HALF OF THE SOUTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 20 AND THE WEST HALF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 29, `s TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, I CITY OF WHEAT RIDGE, COUNTY OF JEFFERSON, STATE OF COLORADO 48 LOTS, 5 TRACTS & PUBLIC R.O.W. — 14.872 ACRES I 1 r 1 LOT 23 3890 1 rI �1 I TRACT USE I A 1 HO.A LOT 16 3831 1 H.O.A. C t UTUTE3 LOT if D UTRITES DRAINAGE k EYEROENCY ACCESS LOT 2 E LANDSCAPING N.O.A. TRACT C 3889.5 LOT 14 C 3m I 3824 3821 LOT 24 3880 h LOT 25 3870 M I LOT 26 3880 LOT 27 3850 LOT 28 3840 LOT 29 3830 1 * I LOT 17 - - - - * I j I 1 3812 11831 O M LOT 8 LOT 1 _ LOT 30 MI 3819 O 11871 3820 1 C I y8T11 PU►_�� POINT a T LS ,ea7 _r LOT 7 w -' TW •1RACT 0 LOT 31 + Lr 11820 t — 'a UN v K I? 3610 BRASS CAP y1p 11880 c r�oR7risioo 1331:• N RANK NI2 I 11890 11880 1 N- 7056727126 E- 1025618715 I 3801 W N O 3800.5 1RACT SE 1/4 SEC. 20� CAP 1 0 of ��` `� 1M►Tf �— _—J DD05TM0 \ I I2' LIB I N I I 1 I I IR TRACT USE TABLE TRACT USE OWNER A LANDSCAPING HO.A 8 DETEMI110H POND k VTMUTES H.O.A. C t UTUTE3 H.O.A. D UTRITES DRAINAGE k EYEROENCY ACCESS H.O.A. E LANDSCAPING N.O.A. 1 N N.O.A. -HOME OWNERS ASSOCIATION 1� I I I IEOE10 1 Nlocx ,RrLR SICWaR COINER R4W. RMT -OF -MY "ammy Lm LOT LINE 0057N0 PLATS rz:71cm uw ROAD O911ER Lm I x I 1 -4 POINT Of OMSV ICDIENT BE CORRNf SEC 20 TM. RRf 6TH P.Y. AWL PPE W/ 3-1/4 BRASS CAP STATED. %S 13512' N RANK BOX PONT ism — — N-705701.5458 E.1052301675 I I— 'SCALE: 1" - 60' CPI Vry.AL tPAOM: _:..LI DEVELOPER ENGINEER \SURVEYOR rlr`■rsn.�6 *"DAIQDPACtfjcHomjs CA RROLL& LA NGE- MA N HARD •/•RV6,Nro anLelA1►a aoYRWPn V A .P. a •et1`..- ��ira: �WriWR.i...�ow1• LOT 16 i LOT 17 11874 ' 1182'0 LOT 16 { I 3901 I 11900 I I LOT 15 V 3899 1 1 I TRACT C 3889.5 LOT 14 1 I 3WO I f LOT 13 j 3879 LOT 12 i � � "� d 3889 I