Loading...
HomeMy WebLinkAbout3535 Parfet StreetINSPECTION RECORD Occupancy/Type INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB''' FOUNDATION INSPECTIONS `. DATE INSPECTOR 'INITIALS' .COMMENTS: Footings /Caissons 1 Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines ' Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED 'CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) 'DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS Sheathing `Lath / Wall tie Mid -Roof Electrical Service �a Rough Electric Rough Plumbing Gas Piping 1Rough Mechanical rABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING: P o Kf; FINALS Electrical Plumbing 1 Mechanical: Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. .Parking & Landscaping': "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION By THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER I pw) ZJb-Lasbb V!!lce - pw) ZJb -Lash/ raX INSPECTION NOTICE Inspection Type: Job Address /Permit Number: J 17-P 116 ❑ No one available for inspection: Time iVLfL�/AAPM Re- Inspection required: 'Yes NoD u� When corrections have been made, call for re- inspection at 303 - 234 -5933 Date: f 1 69 Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Solar PERMIT - 092464 PERMIT NO: 092464 ISSUED: 09/16/2009 JOB ADDRESS: 3535 PARFET ST. EXPIRES: 03/15/2010 DESCRIPTION: Residential solar system * ** CONTACTS * ** gC 713/886-0660 Stacy Ashman 08- .0.178 Standard. Renewable Energy ** :PARCEL 'INFO ** ZONE 'CODE:' UA USE: UA SUBDIVISION:r 0654 'BLOCK /LOT #: -0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 50,868.00 FEES Permit Fee 500.00 1, t Total Valuation Valuation .00 IOo?SDJ� ** TOTAL ** 500.00 JOA �. Conditions:` KC: Approved per plans & engineering letter. 9/27/09 Must comply w/ 2003 SRC & 2005 NEC:. I hereby certify that the setback distances proposed by this permit 'application are accurate, and do not violate applicable ordinances, rules or regulations of the City of aWheat Ridge or covenants, easements or restrictions '. of record; that all me nts shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this plicat n and hat I assume full responsibility for compliance` with the Wheat Ridge Building Code (I.B.C)'. and all other: appl1 Whew Or nces, for work under this permit. P s subject to field inspection. YJ Signature of Ccontr +tor /owner f: date L This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other . applicable ordinances of the city.:: 2. This permit shall expire 180 days from the issue date. :Requests for an extension must be received prior to expiration date. An extension may granted: at the discretion of the Building Official. 3. If this permit expires, .:a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans. and :specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a: new permit. !. No work of any manner shall be done that will change the natural flow of water causing drainage. problem. 5. Contractor shall notify the Building Inspector twenty -four (24) hours in advance for all inspections and shall receive- written approval on inspection card before proceeding with successive phases of the job. 5. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor' an approval of an 7va'.ation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan revi w / -ject to field 'inspections. Signature of Chi' Official :date INSPECTION REQUEST LINE: (303)234- 5933 - BUILDING OFFICE: (303)235 -2855 ZEQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE :FOLLOWING BUSINESS DAY.'. City of Wheat Ridge Building Division m 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 cOroano° Inspection Line: 303- 234 -5933 Building Permit Application Property Address; _: 3S 4 0 ! I. 1LI Property Owner (please print): -61779 Mailing Address: (if different than property address) Address: QA 0.1yQ- City, State, Zip: Contractor: Contracto License #: Sub Contractors: Electrical City License #: Company: Date: 9' 11P1 49-( Plan #. V Permit #: U o? / fN 90 0 33 Phone: Phone: Plumbing City License*: Company a CQ Mechanical City License #: Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Description of work: 6rzS_ '1011w to�ovol+atL 5olar Construction Value: $ J` — Q�$�o �, $ a (as calculated per the Buildfnq valuadon Data sheet) Plan Review (due at time of submittal): $ Sq. Ft. /L.Ft added: Squares BTU's Gallons Amps _ OWNER/ CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. C/RLCE ONEe: R) CONTRACTOR) r PERSONAL REP RESf T TIV of (OWNER) (CONTRATOR) PRINT NAME is J�Ior. SIGNATURE: Date: - 6 -0 3 � STANDARD Renc�+a l>Iv fnE r{;Y � WHEAT u COL JR 0' 0 W� ro' ved 16 September 2009 " BUILONG ibFFICIAL DATE Joan Hess _ Validity of permit: The issuance of a permit or approval of plans, specifr, ^ions Standard Renewable Energy and computations shall not be a permit for, or an approval of, any viola '..:,Q to any of the provisions of the building code or of any City orditiancf 5757 Arapahoe Ave #C -2 Permits presuming to authority to violate or cancel the provisions of the Boulder, CO 80303 Building codes or other ordinances of the City shall not beyalid. RE: Roof Analysis for Solar Photovoltaic Installation 3535 Parfet St., Wheatridge, CO 80033 SRE Project # BRPV4285_Livingston Dear Joan: I have reviewed the existing roof structure referenced above to determine its ability to support new solar photovoltaic panels. The proposed solar addition will consist of modules flush mounted to the roof with the ProSolar Roof - Trac equipment, a proprietary mounting system with method of installation that has been reviewed and sealed separately by a licensed engineer. The solar array will add no more than 3 psf dead load. The flush mount system does not impose an additional downforce wind loading (pst). There is only one layer of shingles on the roof. The array will be placed on the roof in zones 1 and 2, less than 35 feet high with a slope —17 degrees on a home in a location that has a design wind speed (3-sec gust) of 105 mph with an exposure category C. Roof attachments will be made at a maximum spacing of 4' -0" along the rails. According to ASCE 7- 05 analytical methods for cladding, the maximum uplift on the roof in Zone 2 will be 38 psf with a maximum pull of 275 lb per attachment foot. The feet will be fastened to the 2 "x 4" (nominal) truss with a 4 "x 5/16" GRK RSS structural screws (or similar) with a minimum 3" embedment. The screw will be located in the middle third of each framing rafter. To the best of my knowledge, the existing rooftop has been checked and found to be structurally adequate to support the new solar panels when constructed per the proposed plans. Sincerely, Fy _ o11 P .. ._.. V �pNEq cesF� .y APPROVED = 42995 m- Subject to Field Inspections 16Sept09 J6 _ F Chris Boyer, P.E. o � r S O ..... \� Wheat Ridge Building Dept. l �e 1)a1)te.. ,ned. , �GL.... ...Plan Checker 1401 McKinney St, Suite #001 ticusteon. TX 77010 Offivo� f113)11#I4'"iib t r4i- rulI TARt A91n t'www "�rn9.cnrn x STA N DA R 11 Renewahle Energy Roof Flush Mount Loadings & Design Based on ASCE 7 -05, Method 1, Components & Cladding gi � p M1 ' Yl. Job Livingston Location Wheatrdge, CO Roof surface type Fastener type Structural supports z, Roof height V, Basic Wind Speed Exposure Class Kz, height coefficient Kzt, topographic factor Kd, directionality factor I, Importance factor Roof Slope Module area Number of modules Module & Racking weight Safety Factor Array Area qh = Adjustment factors Dead Load Shingle Lag screw 2X4 truss 35 ft 105. !mph C 1.4 18 degrees I , 6 ft2 3 (in smallest group) 38 ' _: lbs / module 2 45 34.70 1.79 2.5 ft2 lb/ft2 psf APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date.2/1 .✓/1 :p Signed..; �: - ....Plan Checker IDownforcel Uplift Force l Overhang Net Design Pressure: All Zones Z1- Middle Z2 -Edge Z3- Corner Z2 -Over Z3 -Over Wind Load 13.7 -23.2 -38.2 -57.3 -48.6 -73.6 psf Z1- Middle Z2 -Edge Z3- Corner Z2 -Over Z3 -Over Number of roof attachmentstmodule 1.71 2 na na na Point dead load 22 19 #VALUE! #VALUE! #VALUE! Ibs Max point load downforce 142 122 #VALUE! #VALUE! #VALUE! Ibs Max point load uplift -190 -275 #VALUE! #VALUE! #VALUE! Ibs Design point load downforce 285 244 #VALUE! #VALUE! #VALUE! Ibs Design point load uplift -380 -550 #VALUE! #VALUE! #VALUE! Ibs Notes: Version: 10Mar09CCB Prepared 9/16/2009 STANDARD Renewable Energy Sif 16 September 2009 ATE Joan Hess Validity of permit: The issuance of a permit or approval of plans, specif - >!ions Standard Renewable Energy and computations shall not be a permit for, or an approval of, any vWla :,n to 5757 Arap Ave #C -2 any of the provisions of the building code or of any City ordinance.. p Permits presuming to give authority to violate or cancel the provisions of the Boulder, CO 80303 Building codes or other ordinances of the City shall not be Valid. RE: Roof Analysis for Solar Photovoltaic Installation 3535 Parfet St., Wheatridge, CO 80033 SRE Project # BRPV4285_Livingston Dear Joan: I have reviewed the existing roof structure referenced above to determine its ability to support new solar photovoltaic panels. The proposed solar addition will consist of modules flush mounted to the roof with the ProSolar Roof - Trac equipment, a proprietary mounting system with method of installation that has been reviewed and sealed separately by a licensed engineer. The solar array will add no more than 3 psf dead load. The flush mount system does not impose an additional downforce wind loading (psf). There is only one layer of shingles on the roof. The array will be placed on the roof in zones 1 and 2, less than 35 feet high with a slope —17 degrees on a home in a location that has a design wind speed (3 -sec gust) of 105 mph with an exposure category C. Roof attachments will be made at a maximum spacing of 4' -0" along the rails. According to ASCE 7- 05 analytical methods for cladding, the maximum uplift on the roof in Zone 2 will be 38 psf with a maximum pull of 275 lb per attachment foot. The feet will be fastened to the 2 "x 4" (nominal) truss with a 4 "x 5/16" GRK RSS structural screws (or similar) with a minimum 3" embedment. The screw will be located in the middle third of each framing rafter. To the best of my knowledge, the existing rooftop has been checked and found to be structurally adequate to support the new solar panels when constructed per the proposed plans. Sincerely Chris Bo APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date.. ? /.0w Signed. . - ..Plan Checker W4lEgT ��F ADO ti it : c � m C o R 1401 McKinney St. Suite 900 1 Houston, TX 77010 Office: ( 713) 888 -0660 1 Fax: (281) 768 -4915 1 www.sre3.com �® STANDARD E Renewable Energy Roof Flush Mount Loadings & Design Based on ASCE 7 -05, Method 1, Components & Cladding Job Livingston Location Wheatridge, CO Roof surface type Shingle Fastener type Lag screw Structural supports 2x4 truss z, Roof height 35 ft I V, Basic Wind Speed 105 mph Z1- Middle Exposure Class C Z2 -Over Z3 -Over Kz, height coefficient 1.4 -23.2 -38.2 Kzt, topographic factor -48.6 -73.6 psf Kd, directionality factor Z1- Middle Z2 -Edge Z3- Corner I, Importance factor 1.0 Number of roof attachments /module 1.71 2 na APPROVED Roof Slope 18 degrees Subject to Field Inspections Module area 15 ft2 #VALUE! Number of modules 3 (in smallest group) Wheat Ridge Building Dept. Module & Racking weight 38 Ibs / module Ibs Safety Factor 2 -275 Date.71:<..�,�oY Array Area qh = 4 34.. 70 ft2 Ib /ft2 Signed.f. .Plan Checker / Adjustment factors 1.79 #VALUE! _ Dead Load 2.5 psf -380 IDownforcel Uplift Force I Overhang Net Design Pressure: All Zones Z1- Middle Z2 -Edge Z3- Corner Z2 -Over Z3 -Over Wind Load 13.7 -23.2 -38.2 57.3 -48.6 -73.6 psf Z1- Middle Z2 -Edge Z3- Corner Z2 -Over Z3 -Over Number of roof attachments /module 1.71 2 na na na Point dead load 22 19 #VALUE! #VALUE! #VALUE! Ibs Max point load downforce 142 122 #VALUE! #VALUE! #VALUE! Ibs Max point load uplift -190 -275 #VALUE! #VALUE! #VALUE! Ibs Design point load downforce 285 244 #VALUE! #VALUE! #VALUE! Ibs Design point load uplift -380 -550 #VALUE! #VALUE! #VALUE! Ibs Notes: Version: 10Mar09CCB Prepared 9/16/2009 Wh eat Ridge Building Depa rtinent Annrn f �v k ss MUST BE S IT] APPROVED Subject to Field Inspections CHIEF BUIL ING OFFICIAL Protect Report ------------ - - - - -� i � Issue Date: 08.28.2009 � ' Project #: BRPV4285 i i i Client: Livingston, Ron Address: 3535 Parfet St. Wheatridge, CO 80033 ' ' Phone: 303.484.8131 System Size: 7.0 kW ' ' Modules: 40 Suntech 175W i i Inverter: Xantrex GT5.0 inverter, ' Xantrex GT3.8 inverter i i i AHJ: City of Wheatridge i Utility Company: Xcel i ' STANDAR D Renewable Energy 5757 Arapahoe Ave. #C2 Boulder, Colorado 80303 3.449.1965 (office) 1 303.440.7391 (fax) www.sre3.com /Colorado Contents --- - - - - -- - ---- -- -----\ i Al - Site Plan APPROVED BY A2 - Module Layout SONYA LOONEY A3 - Electrical Layout ' i El - Wiring Diagram SRE i E2 - Wiring Calculations ' E3 - Placards DESIGN AND E4 - PV Watts ENGINEERIN(I � O ' Data Sheets - Module Data Sheet - Inverter Data Sheet ' - Racking Data Sheet .— System Summary -------------------------------------------------- The following design describes a residential Solar PV system with a peak STC DC size of q& kW ` and an estimated electrical generation of 8786 kWh per year. i The modules form an array on the East and South facing roof oriented at approximately 17 i degrees of tilt. The array on the East roof consists of 3 strings of 10 modules connecting to a Xantrex GT5.0 inverter, and the array on the South roof consists of 1 string of 10 modules i connecting to a Xantrex GT2.8 inverter. i The DC wire is enclosed in conduit, which connects to the inverter, followed by the service panel i and utility meter located on the west side of the house. The inverter feed is 240 VAC single phase. t � t i i Standard Renewable Energy expressly reserves Its common low copyright and other property rlgh6 In these plans. these plans are not to be reproduced, changeq or replied in any loan or manner ,hatsoever without the express written permisslon and consent of Surreal Renewable Energy a ... MM;J1 SQNYA QQNEY ® E - -- Schedule of Components ---------------- •------ - - - -•, -AWD CL NMV ° g v QLL, ¢ai A. Solar array: 40 Suntech 175W o o ZQ nU M b B. Xantrex GT5.0 inverter, Xantrex GT2.8 inverter = Qa^ C. Utility Meter D. Main Panel a ... MM;J1 SQNYA QQNEY 0 DESIG -AWD E NGIN m rn WNG � M N � a O 7 OD m cn O N � Y a) a) M Ln N M d M APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Date..T/ 40' Signed...Plan Checker m Ea o T E FL y3: m - 0 LO iv!i �r � � V C)) Q) C L ) Y [/l t 40 m r- v Al . -- Attachment Detail ............................ ...-Schedule of Components --- ----------- ----- ------- -• I TileTrac Foot 5/16" GRK Structural Screw A. String Wiring Layout 0 -One String of 10 modules -Three Strings of 10 modules Li I I B. Junction Box P o l yure th ane -------------------------------- - ------- - -- --- -------- - --- --- -- - - . -- Attachment Detail ............................ ...-Schedule of Components --- ----------- ----- ------- -• TileTrac Foot 5/16" GRK Structural Screw A. String Wiring Layout with 3" Minimum Embedment -One String of 10 modules -Three Strings of 10 modules I I B. Junction Box P o l yure th ane -------------------------------- - ------- - -- --- -------- - --- --- -- - - R fing Sealant Comp Shingles APPRO SONYA Si 7/16" OSB Deck DESIG ENGIN 2x4 Roof Rafter K M APPROVED Subject.to Field Inspections Wheat Ridge Building Dept. Date... Signed ,mot _ •• .........Plan Checker 0 �g Q ` 403 a Z 2g� e Q„ av V� ° m M NG N M M N O a O > W M Ln O N � t C Y v M Q) M Q) d M N T E o J O E o (D � � V P N I) � Y rn L 90 cn n v M ,---Schedule of Components ----------------------------- A. Conduit Run B. Xantrex GT 2.8 inverter, Xantre! «- ------- -- ------ - - - - -« E APPRO SONYA S! DESIG ENGIN APPROVED Subject to Field ln�pecfians Wheat Age AE Dept. « § a — /. r9ale ...... Chack« EQ BY r" U) 00 N CD 00 0 cl� U) U Co CL U (1) U) 0 Lr) 0 \ F LO (D r� U) 0 Mll Roof mount using Pro -Solar Roof -Trac u - in %" EMT conduit outside of array Xantrex GT 240VAC 3m iner Box 11.7A Ma 15 Fuses UL1741 NEMA3 #10 AWG in 3/4" EMT conduit Lightning arrestors installed L on inverters Inverter ground buss connected to ground rod with #6AWG bare copper wire for 240VAC 21 A Max UL1741 NEMA3 Grounding Electrode Conductor. (GEC) #6 AWG bare copper neutral sense line - 0 - #10 AWG Copper THHN/THWN -2 r in 3/4" EMT conduit I 50A - - l '------ 11 - - - - -- equipment grounding conductor #10 AWG bare Subpenel - 125A Main L 50 A breaker hold -down kit PV signage per NEC 690.53, NEC 6'. NEC 690.64 (B) 4, NEC 690.64 (B) 7 Modules grounded to mounting rails with WEEB clips, mounting rails are grounded to grounding rod with #10AWG bare copper wire with DB rated lugs #6 AWG Copper TH HN/TH WN -2 in 1" EMT conduit --------------------- - - - - -- with APPROVED subject to Field inspections Wheat Ridge Building C Dept. Data..�!.� Signed. 4 Plan Checker APPRO SONYA S1 to service entrance DESIG 4 EN GJN utilit Meter Line Tap - Insulation Piercing Lugs - UL Listed - First disconnect not more than 10 feet from tap (NEC 690) Q ` amp Qa o3 r = o e 3 0 Z =�N a`d N ma m ME ----- IN L M W M N 0 W -O m Y � v m M N CL- M3 E1 AC bonding point G Main Service Panel m m A w E L1 L2 N 200A � - 200A Main Breaker - 200AMain Bus LO -AC Ground Bond d � � U • • C U G Cl) q °v _r u E1 p i �am y Q 3 a o � � U my Z 3 ° o 1 Q -m c ¢`v Ca Photovoltaic Modules Each Module Make Suntech Vmp = 35.2 V Model SPT- 1755 =24/ Voc = 44.2 V Watts STC 175 W Imp = 4.95 A Isc = 5.20 A Inverter Make Xantrex Model GT2.8 Output Wattage 2800 W Output Current 11.70 A w/ 125% Derate 14.63 A Input Voltage Range 195V to 600V Total Modules 30 String Size 10 # of Strings 1 Inverter Watts STC 1750 W For All Strings Isc = 6.50 A 125% Derate Make Xantrex Model GT5.0 Output Wattage 5000 W Output Current 21.00 A w/ 125% Derate 26.25 A Input Voltage Range 240V to 600V Total Modules 30 String Size 10 # of Strings .3 Inverter Watts STC 5250W For All Strings - Isc = 19.50 A 125% Derate APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Da e...�i7xe Signed .. ........Plan Checker i Each String - - Vmp = 352.0 V Voc = 552.5 V 125% Derate Imp = 4.95 A Isc = 6.50 A 125% Derate Make Xantrex Model GT5.0 Output Wattage 5000 W Output Current 21.00 A w/ 125% Derate 26.25 A Input Voltage Range 240V to 600V Total Modules 30 String Size 10 # of Strings .3 Inverter Watts STC 5250W For All Strings - Isc = 19.50 A 125% Derate APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Da e...�i7xe Signed .. ........Plan Checker i n ut ro 00 m N 0 > 00 CL �O Y CD w � ro '— CL m M N a Ln E Each String Vmp = 352.0 V Voc = 552.5 V 125% Derate Imp = 4.95 A Isc = 6.50 A 125% Derate n ut ro 00 m N 0 > 00 CL �O Y CD w � ro '— CL m M N a Ln E w m � E a m (D o E -0 v_ .c i U C c CD t o U) r � E2 Photovoltaic System DC Combiner Operating Voltage 352 VDC Operating Current 4.95 A Maximum Voltage 552 VDC hort Circuit Current 6.5 A by qualified personnel only" lard Renewable Energy 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 Photovoltaic System DC Disconnect Operating Voltage 352 VDC Operating Current 4.95 A Maximum Voltage 552 VDC sort Circuit Current 6.5 A by qualified personnel only" Renewable Energy 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 Xantrex GT2.8 Itaic System DC Combiner Operating Voltage 352 VDC Operating Current 14.85 A Maximum Voltage 552 VDC ort Circuit Current 19.5 A by qualified personnel only" lard Renewable Energy 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 Photovoltaic System DC Disconnect Operating Voltage 352 VDC Operating Current 14.85 A Maximum Voltage 552 VDC ihort Circuit Current 19.5 A by qualified personnel only" ndard Renewable Energy 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 Xantrex GT3.8 Photovoltaic System Utility Disconnect Operating Voltage 240 VAC Operating Current 29A Overcurrent Rating 50A Servicing by qualified personnel only" Standard Renewable Energy 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 Attention: Photovoltaic System Connected Servicing by qualified personnel only" Standard Renewable Energy 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 located at meter Disconnect all sources M before servicing. --- - - - - -- Servicing by qualified person Standard Renewable E 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 ® o U' :lM cl� �o �o �oq O 10 m 10 o This fed by C panel �o z multiple sources. N °c �mm 0 Disconnect all sources M before servicing. --- - - - - -- Servicing by qualified person Standard Renewable E 5757 Arapahoe Ave. #C2 Boulder, CO 80303 www.SRE3.com (303) 449 -1965 ENG m m in cl� �o �o �oq 10 m 10 o N p V cc C �o m v M v L 2 0 T ;_ 0 O ;_ APPROVED T Sub;ect to Field Insp ections Wheat Bodge Building Dept. �Cl) gate.. CO 0 :Man Checker _ - - E3 3 NSUNTECH Solar powering a green future'' 175 Watt Suntech Black Label' modules are exclusively designed and engineered for homeowners who seek a rooftop solar solution that combines visual aesthetics with excellent efficiency. Features • High conversion efficiency based on innovative photovoltaic technologies • High reliability with guaranteed +1-3% power output tolerance • Withstands high wind-pressure and snow load, and extreme temperature variations Quality and Safety • 25-year power output transferable warranty • Rigorous quality control meeting the highest international standards • ISO 9001:2000 (Quality Management System) and ISO 14001:2004 (Environmental Management System) certified factories manufacturing world class products • UL listings: UL1703, cULus, Class C fire rating, conformity to CE Recommended Applications • Residential roof top systems • On-grid utility systems - On-grid commercial systems Surnevicstatheriology Unique design on drainage yields improvements to helm, and H,rd construction BSIF structure and prevents frame from anti opto, 10 increase deforntring or breaking due as conw,rtion to freezing weather and other offitimic, forces Viii.,eno ee E a - 1 8� u m om is named Frost and The panel provides more field power output french an advanced LL V oa mm 't corr 008 so Ene any of STPI 80S - 24/Ab -1 cell texturing and < w isolation process, which r) STPI 75S - 24/Ab -1 NSUNTECH TM impasses low mardiance performance , U Z • BLACK LABEL STPI 70S - 24/Ab -1 , seli < -ra, STP1 65S - 24/Ab -1 �zi,r, ,, Solar powering a green futurd' STP I 60 S - 24/Ab -1 C'n Electrical Characteristics Characteristic; STPI808-24/0.4I 5TP1755-24/Ab4 5TP1705-24/0.4I STP1655 -2411deA STM605-24/Akril Open - Circuit Voltage Wod "AV 44.2v 43 BV 43.6V 43.2V ­­­ ... ... .1, ... - .... ............ .... ..... I ..... .. . .. .: I ...._.I.... ... . 1.11 ... -------------- Optimum Operating Voltage (Vmp) 35.6V 35.2v 35.2V 34SV 34.4V ....................... ­ ............ ...... ............. ... 1.1.1-111 ......................... - ­1 .... ...................... ................. Short - Circuit Current (Isc) 54A 5.2A 5.14A 5.NA 5A - ....... ­­ ...... ­­­ ............ ............ 1- ........... ......... I ?: Optimum Operating Current (imp) 5.05A 4.95A 4,83A 4.74A 4.65A API)ROVEIR Y .......... .. ........ - ....... ­­ ...... .......... 1111 .......... ....... ...... ­ ...... - .... > Maxim . I . . I . P I o w I e I r I I a . t S T C P I m . ax) 18 1 0 1 1 W p I 1 1 7 1 5 .1 We .11.1 1 1 7 1. 0 1 WIP I - 6 5 1 We � 160.W ... SOP IYA I -OdMEY Operating Temperature -40 °C to +85'C -40 °C to +85'C -40*Ct.+B5'C -40 °C to +85'C -40 °C to +85C Maximum System Voltage 60OVDC 600V DC 600VDC 60OVDC 600VDC 6.0. 0 RE-12 Maxim unin Series Fuse Rating 15 AMPS 15 AMPS 15 AMPS 15 AMPS 15 AMPS .. ­ I ...... . ..... DESIGN- DO D PowerTiolorance +3% ±390 ±39'• 1±3 Ss ±3 ^/• . ...... . ................... .... .... . ... . .. STC.Ikradhonoe 1000W/.,M.d.l.lemp..I.le25-CAM-1.5 EN 31NEEQN113 Mechanical Characteristics 00>- Solar Cell Mono crystalline 125xl 25mm (Sinch) Q) 2: oL to N...fCcllr 72(6.12) .............. Dimensions l580x808x35mrn (62.2x3laxI finch) —'ress. ...................... I ........... Weight 15.Skg (34.11bsj ro u) ­ � .... I—- . ................. __ . ­ ................... ­ ......................... ..... Front Glass 3.2 mm (0.1 sloth) tempered glass (1) 00 0 rN Frame Amodired alummurn alloy 0 It 00 A ............... ­­­ . ­ ......... __ ........ Junction Box EP65 rated > 0- ,; 0 Lr) J rpan cl.-o — - t! tc AIW (1 2AWG), asymmetrical lengths N 1200mm Output Cables (47.2inch) and (+) 800m. (31.5inch), MC Plug •= p Type IV connectors Temperature Coefficients (1) M Ln al Operating Cell Temperature (NOCT) 45*C+�*C 2 Ln ci .......... • ..................... ...... Temperature Coefficient of Form, -0.413 r/'C 0- L ................ ... ........................ I .... I ......... ........ .... 11 ............... -... Temperature Coefficient ofVoc -0. 34 %/C -------------- ie I , ormationflosed - Temperature Coefficient oflsc 0.017%/C Current - Voltage & Power-Voltage Curve (170W) Temperature Dependence of Isc, Voc, Poll Viii.,eno ee E a - Suntach n is named Frost and The panel provides more field power output french an advanced 5u1h,c APPROVED or c l o p" Subject to Field Inspections icycr, 't corr 008 so Ene any of cell texturing and w isolation process, which impasses low mardiance performance Wheat Ridge Building Dept. Date .............. Viii.,eno ee E a - w Pro. low C0 E 0 E Lo > CL U) Checker .-CE D XantreXTn GT Series Grid Tie Solar Inverters Electrical Specifications - Output. Models - -I G15.0 GT4.ON Gr3.8 GT3.3N GT2.8 Maximum AC mower autom I 5DOOW 45WW I 4000W 380oW 1 380OW 350OW I 280OW 27COW I 280OW 27M AC Output voltage range 211 -264 Vac 183 -229 Vac Al frequency (nominal 60 Ha AC frequency range 59.3 -60.5 He Maximum mniinuous output .Item 21A I 22A Ih7A 18.3A 15.8A I 16.8A 13aA I 143A 113A 1 13.0 k C Wedmore output over - current protection 30A 25A 20A I 25A 20A 15A Maximum utility badrreed moment 0A Total harmonic distortion (1110) 3% Power factor > 099 or (at rated pawmi,> 095 %(full payw r ran,e) Utility monitoring, slanding protection ULI 741-2005 1 IEEE 1547 Output characteristics Current source ® N V - UO cn ? o w Q ao3 O a 3 G v E 3 L 6 Z ce� N t -m a` ya C v i i to v t m1 ^ Co Co P2 , e --- A ! a Ric M NG The XannexTV Grid Tie Solar Inverter (GT Series) is designed to convert photovoltaic (PV) electriciTy produced by solar modules into utility-grade power that can be used by the home or sold to the local electrical utility. Offering high efficiency (up to 96.0 %), clean aesthetics, high reliability, and a low installed cost, through ease of installation and integrated features, the GT Series is a proven, high - frequency design in a compact enclosure. - The GT Series may be installed as a single inverter, for a single PV array, or in a multiple- inverter configuration for large PV systems. - Technology An NEC compliant, integrated DC /AC disconnect, standard in the GT Series, eliminates the need for external DC (PV) disconnects, and in some jurisdictions, AC disconnects Ir Large offers extraoriina heat dispersion without the need r 9 ry p e o a cooling fan ie Liquid crystal display (LCD) provides instantaneous information - power level, daily and lifetime energy production, PV array voltage and current utility voltage and frequency, time online "selling ", fault messages, and installer- customized screens P LCD vibration sensor allows the tap of a finger to turn backlight on and cycle through display screens Installation Flexible module selection and sizing due to wide PV input MPPT tracking voltage range H Lightweight and versatile mounting bracket H Easy access DC (photovoltaic) and AC (utility) terminal block simplifies wiring e Rugged NEMA 311 inverter enclosure allows reliable indoor and outdoor installations Performance Best -in -class efficiency to maximize solar system return on investment te Accurate MPPT tracking ensures maximum energy harvest under any conditions 5 FCC Part a compliance provides less external electronic interference Serviceability H 10 -year standard warranty I, Sealed inverter enclosure can be quickly separated from the wiring box allowing DC /AC connections to remain intact in the unlikely event the inverter needs to be serviced 0 2008 senors poorness Inc Nl rigor, resmed xamoM onbc aM Smarr dorm for power are aimed In Wnsede Standard 10 -year warranty SPs c- c•,io'ew PHOTOVOLTAIC POWER INVERTER Xantrex Technology Inc. Customer Service/Technical Support customerserviceoxantrex.com Toll free: 1.800- 670 -0707 www.xantrex.com APPROVED Subject to Field Inspections Wheat Ridge Building Dept. Electrical Specifi cations - Input 1-- Maximum array open circuit voltage 60OVdc - - - -- MPPT voltage mnge(CEC is C5A) 240 -550 Vdc 290 -480 Vdc 195 -550 Vdc 200 -409 Vdc 195 -550 Vdc MPPT operating range 235 -550 Vdc 235 -550 Vdc 195 -550 Vdc 200.550 Vdc 193 -550 Vdc Maximum input current nu Adc I 20AAdc ISO Ade 17.OAdc 20.8Adc I 19.5Adc 17.SAdi, I 16.5Adc 15.4Adc 14.9Adc Maximum army short drmi[ current 864 -1032 864 - 864 -100 - 24o Ada R ever s e,nAmity p rotect i on Shoo -drmit lode (iround -fault protection GF detection, IDIF> IA Medmum inverter saturating 95.9% 95.5% 96.0% ' 952% 95.9% 1 95.6% 95:9% 95.6% 95.0% 94.6% CEC effidamy 95.5% 95.0% 95.5% 95.0% 95.0% 1 95.0% 95.5% 95.0% 94.0% 93.5% CEC part number 615.0 -NA- 2401208 GMAN -NA NOON 613.8 NA 24W208 GT3.3N -NA- 2401208 GR. &NA- 240208 Night -time power consumption 1 w Environmental Specifications Operation temperature range -13 ° to 149°F I -25nC to WC) Enclosure type NINA 31! loutdam rated) Inverter weight 58.0 ib 125.8 kg) 58.016(25.8 kg) 58.0 In (25.8 kg) 49a to (22.2 kg) 49.016(222 kg) Shipping weigh[ 11.0 11 (272 kg) 65.0 to (272 kg) 1 65.016 (27.2 kg) I 57.016 125.9 kg) 4.016 (25.9 kg) Inverter dimensions (H x W x DI 28112 x 16 x 5314 "(72.4 x 40.3 x 14.5 an) - Shipping dimensions (H x W x D) 34 x 2018 x 10 5116" (86.6x 51.8x 26.2 cm) Mechanical Specifications Mounting Wall moan,( dog bracket included) Input and omputterminal AC and DC terminals accept wires sizes of M4 to d6 AWG PV I Utility discannect Eliminates need for atonal PV YIQ disconnect Camillo with NEC requirement Coaling Comedian cooled, ran not required Display Backlit, two- line, 16 dimmcter liquid crystal display provides instantaneous power, daily and lifetime energy, production, PV army voltage and meant utility voltage and hequenry, time online 'selling , fault messages, and Installer -cusmmizable screens Communications Integrated 85232 and xanbusrm 8145 communication ports Wiring box PV. Why, ground and communications canes ionxihe invenercan be separated Core thewidng box. Warranty lo,.rsmadam Model name (negative ground) GT5.0- 14A- 24I208UL-OS Gi4AN-NA340R08UL -05 GT3.8- NA- 24ORO8ULA5 513.311- NA- 240R08UL -05 612.8- NA- 240R08UL -05 Part number (negative ground) 864 -1009 86 -1 008 864 -1032 864 - 864 -100 - Penitent, .red inverters are also available Regulatory Approvals _ Certified to ULTl41 19 Edition' 2005 version CSA 107.1 -01 CSA 2 02.2 Not 07-1 -01 general use Fever power supplies. ...sentrexrecari a,. Ali,. renamed xanam, sensor, no Smart ft... waxa trade, acts or rom¢retl trademarb of Yanaex lntemationaL Printed in Canada. N N .0 In M Go M N 0 O OD Of O DO 5� O1 L t) C N M Ln r0 M N CL M co w N p o N j E r y ED 0 _'_ i r � � U F O N C 3 L R O (n t` V 'I'be Fall Jacd' ° crflachmai[ lRueneed above is bow Ile Fast lack" al /admterd saamlesslr bdegmles with the Roof %irv: motmling s slem. professional (800) 84 -SOLAR SOLAR 4630 CalleQ etzal products Carnanllo, CA 93012 All allarlmnod haiduniv is eoncadvel lul /hin the sepleo,I anfl leaving an aeslhelicdllp pl easing sofa- anoy Splice Kit %lie splice Nt provides a solulion to rigidly lock multiple rail sets together. The splice kit has a feature that allowsfor ther- mal eapansion /contraction of the rails without damaging the toof.- -top! For more informalioiz yowl can visit its on the web at www.RoofTrac. coin provides a quick and strong installalion solulion. Our patented design places ibe bolt ativaly uncle) the slanchion post where it ow,eides the ,Iaslsupport.7hisfea- Ito a allows slanclard roofpasbingt III lapllal on [be taofdeck Ibe mmosable post allows flasbings to be slipped over the base wilboul damaging sea, ounding eomposi- lion.sbingles. ca IS ;V Integrated with Tile Trac °attachments \I 71ie Roof Dac "supporl rail erns designed to conceal all allacbmad hardteare. Alt conueclions ae made inside the seppm4 rail bidden frarn view. N V a. ik M ry WO Q w ¢ 3 ^ v iJ v03 Z � �I^L ^9v L / m u t U) m 00 M N O 00 a O �U Co CM N L -a y ii , V N ll) N m a m ' Ibe Tile ifnc© allacbmelil Spleen is 1111rs1ra!edabove is how the Me'Trac liepefect basefor sinface mornrling on All eiposedaluntinum isfidlP anodizedto allacbmeul secanlo&'; iulgymalu will, the composilima )roofs! It has over /e sq. inches modale manufacturer specificalioua. •r Roof Trac "' mounling sTalwn. of base lopreeent damaging delicate -C A� � c• �* E �> U) m 00 M N O 00 a O �U Co CM N L -a y ii , V N ll) N m a m ' Ibe Tile ifnc© allacbmelil Spleen is 1111rs1ra!edabove is how the Me'Trac liepefect basefor sinface mornrling on All eiposedaluntinum isfidlP anodizedto allacbmeul secanlo&'; iulgymalu will, the composilima )roofs! It has over /e sq. inches modale manufacturer specificalioua. Roof Trac "' mounling sTalwn. of base lopreeent damaging delicate -C cotnlowiliorl sbingies. N E �> N O Patented Slide -N -Clamp F ully inte led,andpatented,danapin �e s N 3: actually cl)aiages t!)e strttctuial properties of the System aluuainum channel a'naking itsigniflcantly stronger •�" o a) n ( 9s. this design allows solar iodides to be installed at a lower profile to fbe roofproviding a more aestheh'cadfly pleasing installation. professional Moduled000psai•esp 'icall� ?tRtaFkADVE m engineevedfoa• each she c modutbbIttfIN@S t7 j dt4m $ pE ction IT) °.o.. SOLAR productsz, damping system provic hileardtensiolaon Ile modnle — - fiaiiae seczn'liag the lava Hate in tb ��'��t Ridge Buildinc Dept City of Wheat Ridge -rr J Res. Miscellaneous PERMIT - 092276 PERMIT NO: 092276 ISSUED: 09/11/2009 .JOB ADDRESS: 3535 PARFET ST EXPIRES: 03/10/2010 DESCRIPTION: 22 Vinyl window replacement„ Sentry. doors .(non-structural) CONTACTS owner 303/484-8131 Ron Livingston gc 303/421-7100 Ted Roland. 01-8516 K.& H Windows & Exteriors PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0654 BLOCK/LOT#: 0/. FEE SUMMARY ESTIMATED PROJECT VALUATION: 19,700.00 - ( FEES Permit Fee 417.70 Plan Review Fee 271.51..,p R Total Valuation .00 Use Tax lNk>oU UO r+ 354.60 TOTAL _1,043.81 a, a's_~r:wazd~ Conditions: KC:.Approved. . .30 windows. Subject to field inspection.: I hereby certify that the setback. distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or. regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this., application and that Iassume full responsibility for compliance. with the Wheat Ridge Building Code (I.B.C). and all other applicdyde Wheat O d' anc or work under this permit. Plans subject to field inspection. Signature of contractor owner date 1. This permit was issued in accordancewith the provisions set forth in your application and is subject to the laws of the state of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other. applicable ..ordinances of the. City. 2. This permit shall. expire 180. days from the issue date. Requests for. an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, 'a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1). year, full. fees. shall be paid for a new permit. 4. No work of any manner shall, be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases. of the. job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to bea permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All pl r i is subject 'to field inspections. . SignatuZION f.C of :Building Official date 'INSPH REQUEST LINE: (303)234-5933 ' BUILDING OFFICE: (303)235-2855 - REQUESTS' MUST BE -MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 9os6'3Cl~~yoSBy G ruitrl}rant City of Wheat Ridge Building Division [Da : 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-235-2857 Inspection Line: 303-234-5933 it Cl Building Permit Application Property Address, 3 5- 37 ~ x-re r ST Property Owner (please prtnt): 90 1A t h o h Phone o Mailing Addressi (if different than property address) Address: City, State, Zip: Contractor: ow O/zS iL7 15 Contractor License f ~s`6 Phone; x jJ Electrical City License Plumbing City License IvleChani I City License Company: Company Compan Exp. Date: Exp. Date: Exp Dat r,lrpruvar. Approval: Use of space (description): f 4,11614 ord 5 d- 9oK-f Descripflon of w}irki /J ~Z (/r~ry/ ~~4`RGEra1EnT ~rsilal~BWf _l,-r~, Eon struction Valuef OLD O O [ calculated per the Building V I bn Dafa sheet) Plan Review (due at time of sub Meg: S 3 £ti7/zy ®Bns X11<e if Gr/le_ Size C.!1ON-5r0rvr- a Sq. Ft./L.Ft added: Squares BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not viola applicable ordinances, Mes or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all msurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this appiiceti - n and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ric a Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) CONTR kTOR) PRINT NAME: VP. pT~Ay~~ SIGNATURE: Date: r/-/O'O 'FIRE DEPARTMENT'.:! ❑ apprpvad W/ comments ❑ disapproved ❑ no M*ewiregUlrad Bldg Valuation: I Ir JOB#:265S/3,L Contract Date MEASURE SHEET SALES REP: I'. Customer Name: V uC 5't-d~ Line Width Height Vents Config./ Add. Info Location i Address f rJ city 3 0 oc/ 4~-/ State. Zip: Home phone: Work phone: ~J 8linds:Type Jambs. / Ladder Needed / Electric available l G✓ al/ / ~ end or 3rd story Jy lo(J` $LL,~ ,Qa C._. steel casements 6< uPe Steel bucks / J l IJ S~J~Q t Siding' . a ld 5 J 6LS Grid Type Storm removal-In or Out ~r Brick or Frame / ! S N1ullioiis lo( J L( $ay or: Bow-Roof or Soffit q cC 77 / 45 inglQ style a J / ~ i~ Angle Size a ~+s < . . / .3 v Casing Sill Special N otes: ~ ' Apron W 9Z q lfTGdu22 ~ Gd M` Co t a I6 '~7 ~a ♦ i CITY OF WHEAT RIDGE ~-j Bung Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address:- Permit Number: /D I 'l No one available for insp6odtion: Time U,1d i R4-,inspection required: Yes No When corrections have ben de call for re-,inspection at 303-2345933 Date: Inspector: yv DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division r' (303) 234-5933 Inspection line _/(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 127 Job Address: Permit Number: n q A ICI ❑ No one available for inspection: Time AM/PM Re-.Inspection required: Yes No *When corrections have been made, call for re-inspection at 303-234-5933; r Date: 17 0 c) 6 ii`=i' Inspector: DO NOT REMOVE THIS NOTICE ?2m-rv >.~:cl'r ~e°~-u. ~.arm,rorot'.a~.+'+°:r _a~s;+z.~;'S vi+,~S.:.veti. i,.+~.r.-..--®~ i ✓ CITY OF WHEAT RIDGE Bung Inspection Division f (303) 234-5933 Inspection line _(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ~f c1 "T - Job Address: 3 5 5' 7,777, -1-.S -L Permit Number: 61 ~2_ 1 ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No " When coffections have been made, call for re-inspection at 303-234-5933 f Date: 3 f1 Inspector: Ai' L /DO NOT REMOVE THIS NOTICE ` A City of Wheat Ridge Residential Roofing PERMIT - 093821 ro PERMIT NO: -..093821` .`ISSUED: 11/03/2009 JOB 'ADDRESS:: 3535 PARFET ST.. 'EXPIRES: 05/02/2010 DESCRIPTION: T/o: Install 37.7 sqs of GAF/Elk: 30 yr shingle.t CONTACTS owner 303/484-8131 RonLivingston gc 303/420-0986 Dan`Cupit 06-0114 Professional Roofing, Inc.' **PARCEL .'INFO ZONE CODE: UA USE: UA SUBDIVISION:' 0654 (BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT 'VALUATION: 19,523.40. FEES Permit Fee 417.70 Total Valuation .00 Use Tax ,.351.42 TOTAL :..769.12 conditions: S nail installation mid roof inspection required. Board sheathing spaced more _hana 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield' required from eave edge to 21 inside exterior walls. k**Contractor/Property owner shall provide ladder(s) secured in place for inpsections.- >ub3ect to field inspection. I hereby certify: that the setback distances proposed by this permit application. are accurate, and do not violate applicable ordinances, rules or regulations of the City of 'Wheat Ridge or covenants, easements or restrictions of record; that all measurements ho , and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application n hat I assume full responsibility for compliance with the Wheat Ridge -Building Code .(I.B.C) and all other applicabl Ridge dinan ,.for work under this pe mi lans'subject to field inspection. Signs ur of c c or/owner d to This permit was issued in accordance with the.. provisions set forth in your application and is subject to the laws of the State of Colorado and to. the Zoning Regulations and Building Codesof Wheat: Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may.; be granted.; at the discretion of the Building Official'. If this permit expires, ;a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment: has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year,.'. full fees shall BUILDING OFFICE': (303)235-2855` :SS :DAY FOR (INSPECTION THE FOLLOWING BUSINESS DAY. F City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Property Address: Property Owner (p)er mailing Address: (if different than property address) Address: Sub `Contractors- Electrical City License Company: Plumbing City License Company Date: Plan M Permit M Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ f915 Description of. work: (as calculated per the Building Valuation Data sheet) ea,- 0e, 5 /Ay~S T (1> 4-2 Q~G Plan Review (due at time of submittal): $ /I& p4e,:' :_i~q yr Sq. Ft./L.Ft added: Squares 37 7 BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field Inspection C)RLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL-R€PJ PRINT NAME: e ~A SIGNATURE: ml Date: + 3 i Building Permit Application Contractor License 10011 Phone: _(n2 ity of Wheat Ridge Agesidential Mechanic PERMIT - 060020 PERMIT NO: 060020 ISSUED: 02/16/2006 JOB ADDRESS: 3535 PARFET ST EXPIRES: 08/16/2007 DESCRIPTION: Replace boiler 140,000 BTU w/ 90% efficient. CONTACTS GC 303/421-2161 01-7835 Blue Sky Plumbing owner 303/819-9021 Ron Livingston PARCEL INFO ZONE CODE: UA USE: R-3 SUBDZVISION: UA BLOCK/LOT#: 0/ FEE SUhIIM7aRY ESTIMATED PROJECT VALUATION: 7,390.00 FEES Permit Fee 199.30 Total Valuation .00 Use Tax 133.02 va TOTAL 332.32 Comments I hereby certify tha[ the setback distancee pmposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of wheat Aidge or covenants, easements or restrictione of record; tha[ all measurements shown, and allegatione made are accurate; that I have read and agreeto abide by all conditions prin[ed on this application and that I assume full reaponeibility for compliance with the wheat Ridge Building Code (I.B.C) and all other applicabl? Wheat F,ddge din , for w ucr,this p=rmit. anuct to field inspection. 2 ~ / / Signature 1. This peYmit wae iaeued in accordance with [he provieions set forth in your application and is subjec[ to the laws of the Sta[e of Colorado and to the Zoning Regula[iona and Building Codes of Whea[ Ridge, Colorado or any o[her applicable ordinances of [he City. 2. This permit shall expire if (A) the work authorized is vot mmmenced wi[hin eixty (60) days from isaue date or (B) the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expiree, a new permit may be acquired for a fee of one-half the amoun[ nozmally required, provided no changes have been or will be made in the original plans and specifica[ione and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (ll year, full fees shall be paid for a new permit. . 4. No work of any manner shall be done [hat will change the na[ural flow of waCer causing a drainage problem. 5. Contrac[or shall notify the Building Inapector twen[y-four (24) hours in advance for all inspections and ehall receive written approval on inspection card before proceeding wi[h successive phases of the job. 6. The iesuance of a permit or the approval of drawings and apecifications shall not be conatrued to be a permit for, nor an approva_l~~ sof,~any viola ~f the provisions of the building codes or any other ordinance, law, rule or regula[ion. All plan yrv~yg ect to fiel'3jinspections. SiqnatHfe of INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. cRri, of Wheat Ridqe PRESCRI~VE ENERGY CO gp LERS 1 FURNACES A MINIMUM OF 90% AFUE GAS WATER HEATERS A MINIMUM OF.60 ENERGY FACTOR ELECTRIC WATER HEATERS A MINIMUM OF .93 ENERGY FACTOR ~T) SET R 21 WALLS ~ RJ8 CEIL~INGS (E R19 CRAWLSPACES ,~2/16/2006 10:56 3034240495 BLUE SKY PLUMBING PAGE 02 BUILDING INSPECTION DIVISION - 235-2855 . Date :1''IMO& CI'iY OF WHEAT RIDGE 7WHEA?ERIDGE COV80215 Property owner: ' Properiy Address : Controctot License fJo. Y : . 'ComPaM19 ~ ~1~.uvC OWNERICON7RAC70R SIGNA7URE OF e , , ;e.'t s'}, 1~~ Pnone : 30 3~ g ~°I ~ D 3~- ~ AND fko+ Phone:3O3r~o~~=~-I Yl.I I hef0hy te41(y thal ihe setbark dlstanCes proposed hy lhu permil appliation are eaurale, and tlo not vlolale apDliahle ordinances, rules of regulatione ef ihe City of Wheaf Ridge or wvenanls, easemants er resirictions o[ record; thal aA measurements ahar nled on Iryjs adons made are aecurale; lhal I bave read and agree lo ablde Ey all rAndillons p~ applialion end thai I assume NII respansibility ~e~cornpleance witp lh~`~ eefRhis p8~ding Code (U.B, ,C.) and all other applicable Construction Value : -1-3 q ~ Permit Fee : Use Tax : UE : (OWNER)(CONTPAGTOR) SIGNED~ _ -pATE 140)000 B'tlt' DescripCwn : CIplo • 6UILOING DEPARTMENT USE ONLY SIC Approval: Zoning : 6M18irt=VMM=I APProvai: PU61[~.1N~ r qpproval: Occupancy : Walls : Electrical License No : Company : Expiration Date : Approval: (1) f71 f~I (5) (81 7otal : r $,00 5q. Ft : Stories : Residenlial Units : Mechanical Lieense No : Company : Expiration Date : Approval: ir e0p~~a^ ^"d Is xubieet a uie Ia+e af Ne Suta ot CobnEO+~+d m the 2oning fpliaeWe erGn?~s el ~he Gly. m,diy (90) deys fmm u~ dak' or (9) U~e OWbinp aNhMZed ~b lV+pMdb ~ Ihe anevM mmmalM n-Wulred, provpea no rnan9cs new he9n arvNn be made In Me iz nol e*ceedW on1-0) YEar. II changes are mfde a M wspen~bn a e~andenrte~l P~'mana. Itie Uaal Aw of water uu9'm9 a drainage poolem. wr (241 neun In aewnu mr on inaceC110"' en0 fhatl rnalva weItlen aP 6 ~m I^ "~O~a~On° ~~p0vlsbna SfM 6~n08110M1F Sh211110I E! R1I141NC410 E! i~rtllil fOf, f10f ill lppf~I o ~ Of fEQU18U011. ' For Mayor ChieF Building InspecWr THIS PERMIT VALID CONLY ALLW2 bS933 24 HOURS PRIOR 70INSPECT ON ~~TOR AND MAYOR Roof: Plumbing License No : Campany : Expiration Date': Approval; 6 iDt w~ark~l~ ~ ~ - -:rw*» 1'SA'1'E~,~„ r EN7`RY Ripb#: ~~a" ~I ~ ~~W~ ~I ~ ~bbsrv~NCk~haYlu~'~p~itl~tvMo1,l~0t~;~ ~ M~ Na 5 . ~4 r . . . ; ~ t ~ ~ } k ' x 3>u t , ~ } • i j y`~ Ar s ~ ~r ~ ~ ~ r ~ DEPARTMEAIT OF PLANNING AND DEVELOPMENT Building Permit Number : BU','LDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : 91_4c~ 62 / ~l ,3j, ~ l-'" ✓ ~ !L Property Address : :5 Phone : Contractor License No. : Company : 71 Phone : ~2f=i?77 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : 1_2 I hereby certify that the setback distances proposed by this permit application are accurate, PerR11t F88 : and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan Review Fee : made are accurate; that I have read and agree to abide by all conditions pnnted on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building U50 T8X : Code (U.B.C.) and all other applicable Wheat Ridge dina es, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ~ ti'7 DATE 9 TOtel : Description: ~cZ-f BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval: ¢ /o l 2- Zoning : Buifd~od~Gommen'ts'~ Approval: P,utili . nts:l Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical Licen Plumbing License No : Mechanical License No Company : Company : Company : Expiration Date : Approval: 18 Expiretion Date : Approval: so ~P~,laffl's'?R~fred_~I Expiration Date : Approval: im EfSFt3~"mRe~~"a(ii~. (1) This permit was issuetl in accortlance with ihe pmvisions set (orth in yopur application and is subject to the laws of the State of Colorado and lo the Zoning Regulations and Building CoOe o! YVheat Riage, Colorado or any other applicable ordinances of the Ciry. (2) This permit shall expire it (A) the work authorrzed is not commencetl within sinty (60) days from issue date or (8) the builCing authonzed is suspentled or abandoned for a penod of 120 days. (3) If Nis pertnit expires, a new pertnrt may Ce acquiretl for a fee of one-half the amount normally requireU, provided no changes have been or will be made in the onginal plans anC specifcations and any suspension or abandonment has not ezceetled one (1) year. If changes are maEe or it suspension or aDandonment exceeds one (1) year, full fees shall be paid for a new Oertnit. (4) No work of any manner shall be tlone that will change the naNral flow of water causing a draina9e problem. (5) ContraIXOr shall notiry the Buiiding Inspecior twenry-four (24) hours in aEvance for all inspec(ons and shall receive written approval on inspeclion wrd before proteediing with succe5sive phases of Ne1ob. (6) The issuance o( a permit or the aDOmval of drawings anG specifca6ons shall not be wnstrued to be a permit for, nor an approval of, any violation of Ne provisions of the bUiltling code5 or any Olher oMinance, laW, rUle of fegulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 3042 BUILDING INSPECTION DIVISION - 235-2855 " CITY OF WHEAT RIDGE Date : 5/8196 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : HAINDEL CLARENCE J Property Address : 3535 PARFET ST Phone : Contractor License No. : 17209 Company : B 8 L Contractors Phone : 429 3757 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pertnk application are eccurate, and do not vblate applicable ordinances, rules or regulations of the Gry of Wheat Ridge or covenants, easements or restridiona of record; that all measuremenfs shown, and allegetlons made are accurate; that I have read and agrea to abide by all condftiona printed on this application, and that I auumefull responaibil'rty for compliance wRh tha Wheat Ridpe Buiiding Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for woAc under this pertnR. (OWNER)(CONTRACTOR) SIGNED DATE Description : ADD 2ND STORY AND FRONT ENTRY Constructlon Value : $46,000.00 Permit Fee : $388.50 Plan Review Fee : $0.00 Use Tax : $552.00 Total: $940.50 BUILDING DEPARTMENT USE ONLY S~ Approval : SM 517186 Zoning : R-1A Approval : JE 517196 Approval : GK 517196 Occupancy : Walls SIC : Sq. Ft. : 7477 C.O. APPROVAL CONTINGENT UPON EXEC11111131111111M;U DEVELOPMENT COVENANT Roof : Stories : Residential Units : Electrical License No : Company : Plumbing License No : Company : / 99 $S Mechanical License No : /XC/a'S/ Company : 5 v /}7E~i jq,uleM~ -TdC. Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : B s 0 (t) This pemtif was lesued in auurtlance with the provisions set forth in Yopur appiication and is suMec[ W the laws of the Stffie of Cobretlo and M theZoning Repulationa and BulWinpIf Coda M Wheat RMpe, Colaatlo or airy Mhx epplicade oMinances of the Cily. (Z) ebai n penrit fo eal pex~'nod of~120 dawork auMOnzed is not canmanaA wlThin elxly (80) daya fran lasue date or (B) Ne buiWing auGwrizatl Is suspended or (3) If thls permit ezpiree, a new pamirt mey be acquired tw e fee of ono-haNthe emaunt iwrtnaNy requiretl, provitletl rro changea have heen or wlll be made in Me orlpinal plans and apedflcedons and any suspensbn a abendonmeM has not ezceeded aie (1) year. If chanpes ere made or if suapansbn w abanEOnmenl exceetls one (1) year, full few shall be peltl far a irow pertnlL (4) No work of any manner ahell be done thet wlll change tha naturol flow of xreter ceuafny a drainage probkm. (5) Coritre~clor sAall noUy the Buittling Inapeclor twenry-tour (24) hours in advarke 1or ail Inspecliona and shall recelve wrilten apProval on Inspectlon card before proceetllinp with suaesaive phases of thep' b. (e) TTe leauance of a permit or the approval ot tlrewings and apedlkatfons shall not be construe0 to be a pertnit for, nor an approval of, aM violatbn of the provisbns W tlhe buil g c des w erry other ordi ance, law, nila or regulatlon. ( . c-, uilding Inspector Fo KA~ yor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : Froperry owner : f~.9i:~/I~G > '~%u•'J Y ~~it,~ Property Address » Phone : Contractor License No. 72 c%9 Company :811- Phone :-)!~2 y- 37S 7 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit aOPlication are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge prdinances, fqr)work under thi"ertnit. (OWNER)(CONTRACTOR) ~t Construction Value : Permit Fee : Use Tax : Total : Description: BUILDING DEPARTMENT USE ONLY ~ m=~ s/i/a1a Approval : 15yi,% Zoning : rL1A. B~11C Iri~ Approval : P bII6``W - 8h't8:~ C.O. q~'eJ0.~ Approval 1 (+l-( q Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: J Plans.Re'_qulred:T_'j ~-J Pltfps:Required A mjSnsf.t6qui[8ii~l (1) This permit was issuetl in accartlance with the provisions set lorth in yopur apphcation and is SuEject to the laws ot the State ol Colorado and ro Ihe Zoning Regulations and Building Code of VJheat RiCge, Colorado or any other apPlicable ordinances ot tne Ciry. (2) This permlt shall eapire if (A) Ihe work authonzed is not wmmenceA within sizry (60) days from issue Cate or (8) the builtling authonzed is suspentle0 or abandoned for a penoE of 720 days. (7) If this permrt eapires, a new Oermit may be acquired for a lee of one-hall the amount normaily reQUired, provitleA no changes have been or will De made in the original plans and specifications and any suspension or aCandonment has nol exceeCetl one (1) year. If changes are matle or if suspension or abanAOnment ezceeds one (1) year, lull tees snall be paid for a new permit. (a) No work of any manner shall be tlone that will change the naNral flow of water causing a Grainage pmblem. . (5) Contractor s 1 notiy the BuilEing Inspecror hvenry-four (24) hours in atlvance lor all insp ns anE shail receive written apProval on inspeaion wrtl bePore proceetliin wi successive phases of the lob. (6) The issVd=d it or the approv of drawings ana specifications snall nit for, no an pp v I of. any violaoon of the pmvisions o/ the b any o~he ortli a ule or regulation. - Chief ui ding Inspector For Mayor T IS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTO AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNIN6 i DEVELOPMENT REQIIEST FOR PIIHLZC iPORRB REVIEW Date: Case/Building Permit No. 36ya Location: S ~ Gpa~"Iz3'" Plea e r v ew th ~tac ed m terials submitted in application for approval of a_ dv, ~ - Ld indicate our decision on those items check below, ai;d please add~ /einy other comments which you may have under number 18. 1. ~ Boundary Closure: K OK _ Not OK; refer to Stipulations 2. L Area: Acres - Square Faet 3. L Drainage: a. Drainage plan (and report) needed b. Drainage plan not needed X c. Drainage provisions have been reviewed and are found to be: _ OK _ Not OK; refer to stipulations 4. / NPDES Permit Required Y ~N 5. Legal Description: X OK Not OK; refer to stipulations If not okay, please explain: 6. Public Improvements: a. Street paving needed Y b. Curb & Gutter needed Y c. Sidewalk needed Y~ d. Street Lights needed Y e. Storm Sewer needed Y~ f. Escrow required Y If Escrow required, for what improvements? In what amount? 7. / Development Agreement required % Y/ If Yes, for ~urb ~ a~~ ...a.,ikl1/~ ~ ~.~croV~i~ '\s 12~ 5.~~ 5- 4~ ~ c~-•=~ ar~~ 8. / All necessary documents have been initiated by Public Works and are attached hereto: (1~,c 9. Is a traffic impact analysis and report required? Y O 10. 11. i Is a State Highway Access Permit needed? Y N~ New roadway or alley R.O.W. dedication is recommended: ~ If yes, what is recommended: 12. ~ All existing dedicated roadways and alleys meet the standards of the city: ye~o If no, which do not and what is requested: 13. All existing and proposed dedications have been reviewed and found to be: x _ t oK; refer to numbers 11 & 12. 14. ~---Appro al: Th Public rks Department has reviewed this request and hereb giv itsovsubject to the above and/or attached stip lati s. s 15. 16. 17. i 18. ~ s /7 / 96 Date The Public Works Department has reviewed this request and does not approve for the reasons stated: Signature Summary Comments: Date A:\PLAN&DEV.FRM (FORMS) Stipulations attached: Yes INo) DEADLINE DATE FOR PUBLIC WORKS DEPARTMENT REPLY: WHEN RECORDED MAIL TO: DOCUMENT CONiROL DEPARTMENT P.O. BOX 7024 PASADENA, CALIFORNIA 91109-8974 CFC LOAN 9149012 ESCROW/CLOSING 50054987 Prepared by: D. EASON ~ SPACE ABOVE FOR RECORDEH9 USE DEED OF TRUST THIS DEED OF 7RUST ("Security InswmenC') is made on December 16. 1993 , among the grantor, CLARENCE J. HAINDEL AND SULINDA K. HAINDEL . AS JOINT TENANTS ("Borrower"), the Public Trustee of J E F F E RS 0 N County ("Trustee"), snd the beneficiary, AMWEST MORTGAGE CO., INC. which is organized and ezisting under the Iaws of COLORADO addressis4155 EAST JEWELL AVE. #910 DENVER, CO 80222- ,and whose ("Lender"). Borsower owes Lender the principal sum of ONE HUNDRED EIGHT THOUSAND SEVEN HUNORED FIFTY and 00/100 Dollars (U.S. $ 108750.00 This debt is evidenced by Bortower's note dated Ihe same datc as this Security Inswment ("Note"), which provides for monthly payments, with the fWl debt, if not paid earlier, due and payable onJanuary 1, 2024 . This Security Inswment secures to Lender: (a) the repayment of fhe debt evidenced by the Note, with interest, and all renewals, eztensions and modiCcations of Uhe Note; (b) the payment of alI olher sums, wiUh interest, advanced under paragraph 7 to protect the security of this Security Inswmenr, and (c) the performance o( Borrower's covenants and agreements under this Securiry Inswment and the Note. For this purpose, Borrower, in consideration of the debt and the wst herein created, irrevocably grants and conveya to Trustee, in wst, with power of sale, the following described property located in J E F F E R 50 N County, Colorado: LOT 14, DANIELS SUBbIVISION, COUNTY OF JEFFERSON. STATE OF COLORADO. which has the address of 3535 PARFET STREET WHEATRID6E Cobrado 80033 - ("Property Address"); (7_ip Code] COLORADO - Single Family - Fennla MaelFreddie Mac UNIFORM INSTRUMENT (we •Bfl(C~.O) (9209) C.Fr. (9192) VMP MORTOAOE FORMS .(913)293-8100 - (800)521-7291 ' 2 3 9 9 1' [stmec. city], Form 30061/91 p,qe i oi e Amsnded 5191 Innlelc ' 0 0 9 1 4 9 0 1 2•• 0•• K S 0 A 0• r2~z eI X,> 7 /10/96 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215-6797 (303) 2345900 City Admin. Fax # 234-5924 May 7, 1996 Police Dept. Fax # 235-2949 Mr. Bud Haindel 3535 Parfet Street Wheat Ridge Colorado 80215 T1-,e City ol "'Wheat GRidge Re: Department of Public Works Requirements for Building Permit Application Dear Mr. Haindel, The Department of Public Works has reviewed the building permit application for the proposed addition to the single family residence at the above referenced address, and has the following comments: 1. In accordance with Section 5-45 of the Wheat Ridge City Code, a Development Covenant will need to be processed. Briefly, this document stipulates that the homeowner will be responsible for the cost to construct those public improvements along the property's frontage for a period of ten (10) years should the City improve Parfet Street within this period of time. This document is required in lieu of constructinq said public improvements. The building permit can be issued at this time. However, please be aware that the Public Works Department can not approve the Certificate of Occupancy until the above referenced document has been procaes@d. If y have any questions, please contact me at 235-2868. Si er,ely, i Greg nudson Development Review Engineer lJA l~ lai-li cc: John Oss Sr. Project Engineer John Eckert, Chief Building Inspector ~F1 Meredith Reckert, Planner II File , DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 GITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner Property Address Contractor License No. Company ~5ue a t3ud Nainde I 353z; l~a~fe1" SI` /'74<F 5 teperc. /Quof~n ~ Phone : 4aµ -9zoz Phone : V33 - yD60 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certity that the setback distances proposed by this pertnit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covanants, easements or restnctions of record: that all measurements shown, and allegations made are accurate; that I have read and ayree to abide by all conditions pnnted on this application, and that I assume full responsibi iry for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable W 6 Ridge rdina es, for work under this permit. r (OWNER)(CONTRACTOR) SIGNED _ DATE --7/'- Description BUILDING DEPARTMENT USE ONLY Approval: Zoning : Approval: Approval : Occupancy : Walls : Roof : Stories Construction Value : 3I rv6.ob Permit Fee : Use Tax : Total : Residential Units : Electrical License No : Company : Plumbing License No : Company: Mechanical License No : Company : Expiration Date : Approval : `w.' Expiration Date : Approval: F wiW ';;a Expiration Date : Approval : a (1) 7his permit was issuetl in accortlance with Ne pmvlsions set foM in yopur application and is subjecl to llte laws of the State of ColoraAo and to Ne Zoning Regulalions and Building Cotle of VJheat Ritlge, ColoraAO or any oNer applinDie ortlinances of Ihe Ciry. (2) This permit shall expire if (A) ihe work authonzed is not commenced within si:ty (80) days trom issue date or (B) the building auNOrized is suspended or abandoneU for a penotl of 120 Cays. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount noimally require4 provided no changes have Eeen or wi11 be matle in the original plans entl speafiwtions and any suspension or abandonment has not exceedetl one (i) year. If changes are made or if suspension or abandonment exceetls one (1) yeac NII fees shall Ee paitl for a new permit. (4) Nb work of any manner shall be done that will change the natural fiow of water wusing a Erainage problem. (5) Conlraclor shall nofity the BuilOing Inspector twenry-four (24) hours in atlvance for all inspecUOns and shall receive wntten approval on inspec9on cartl before procee0iing with successive phases of Me job. (6) The issuance of a permit or the approval of Erewings and specifications shall not Ee construetl to be a permit for, nor an appraval o( any violauon of the provisions ot Ihe Ouilding cotles or any other ortlinance, law. rule or regula6on. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 WESr 29tn AveNUE BUILDING INSPECTION DIVISION PERMIT N0. M91#17258 237-6944 EXT. 255 P.O. eoX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTEDBELOW. PPLICATION FOR MISCELLANEOUS P~FFR{^~~,,,,~~IT JOBADDRESS~T~~ OWNER ( ~nrin~e~ CONTRACTOR ADDFESS ~ ADDRESS PHONE y2 y'9~QZ` ZIPCODE O3 CITY ~ ZIP CODE CONTRACT PRICE $ /UOU' OQ PHnNF U LICENSE NO. DATE TVPE Ground❑ 1 Woll❑ ProitctinQ❑ 01Mr SaDFace . MATERIAL Tafal Squoro Fee1 SIGNS 2. ILWMINATION Y ❑ N ❑ 3 a T Eleef P~r t No es o . 4 SET BACK FROM PROPERTY LINE N (Specify whith ia front) YD _ ❑ 5_ E ❑ _ W ❑ ❑ . Zom~DWmed,Zone Incpeclor DisapprOVed 1. TYPE Solic, d Mor Thon 90% MATERIAL I/"DO ? ODenO Laos Thon BO% Open H~ipM FENCES . 1 SET BACK FROM PROPERTY LINE N (SDecify whicA is }ront) _ ❑ S_ E ❑ _ W ❑ ❑ 2on rw ,XoneInmpaotw asaODrova Z.-7- I . 2 OTHER E . DRAW SKETCH OR SHOW BEIOW, TNE FENCE,SIGN,OR OTHER STRUCTURE,GIViN3 DISTANCES FROM PROPERTY I.INES. (SETBACKS OR PROJECTqNS INCLUDED) ~ ;IFY NORTH SNOW DISTANCES FROM THE MAIN BUILDIN6 TUADJOINING HOUSES, STREETS, AND VROPERTY LINESiON IRREGULAR LATS, SNOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR qVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 DAYS FROM THE DATE Of ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE UCENSE N0. PLUMBING PERMIT STATE UCENSE NO MECHANICAI. PERMIT ALUMINUMVAREUNDERSIZEBILLEGAI fL00R BSM I5T 2ND 3RD 4TM N0. Fl1ELCirtJeOnaGoi0111prOpdis ElxSolor Np, WATER CIASET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - 8TU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-8N LIGHTING SINN OTHER HEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SU6-LIFCUITS UTILI7Y(RANGE,DISPOSER,ETC) FI%TURES WATER HEATER AUTO. WASHER DISH WASHER Retri eraM Group Pounds Char e AUTOMATIC SPRINKLER SYSTEM WIRIN6 MOTOF25 9 CONTROLS f11NJR DRAIN EIEVATOR SIGNS URINAL TRANSFORMERS 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP . TOTAL FI%TURES _ ~ / 1 Mreby ocknowledqe that this aDDIica- tion is cOrrect and understand that I connof Harf this projtltt unfil this oDPli- eotion is ap0roved. I shall comply with the lowe of the Stote of Colorodo and ro tha Zoninp Requlations and Bwldinq Code ofthe Ciry of wneat Riaqe. Any violotion of fhe above tlrme will couee immediate revocahon of thls vermil PERMIT FEE S, Q6 NOT~VAUD UNLE55IiECEIi usE Tax Q- p0 TOTAL FEE $ Oa ~'c~,~•~'r APPROVED DI&dPPR00E~ CHIEF BUILDWG I SPECTOR,Gfy5of Wheat Ridqe I CAL1237-8944 EXT.255 24 HOURS IN ADVANCE Date I55ued ~ ~ ~ ~ FOR INSPECTIONS