Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7615 W 38th Avenue
City of Wheat�dge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29� Ave. November 17, 2021 Andrea Mehlem Essex Financial Group 1401 171' Street Suite 700 Denver, CO 80202 SENT VIA EMAIL Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 Re: Zoning Verification for 7615-7777 W. 38d' Avenue / Wilmore Center To Whom It May Concern: Please allow this letter to serve as zoning verification for property located at 7615-7777 W. 38d' Avenue, known as the Wilmore Center. The property is within the corporate limits of the City of Wheat Ridge and has parcel ID 39-233-21-030. The subject property is currently zoned Mixed Use -Commercial (MU -C). This zone district is intended for major commercial corridors and at community and employment activity centers. In addition to residential and civic uses, the district allows for a wide range of commercial and retail uses and encourages medium to high-density mixed-use development. Refer to Section 26-1111 for permitted uses in MU -C. It is my understanding that the existing businesses in the center include retail, restaurant, office, medical and service uses. These types of uses are permitted in the MU -C zone district. I have not confirmed whether or not Wheat Ridge business licenses are active for each tenant on the property. Tenants should each be able to produce a local business license upon request. Alternatively, you may contact the City's Licensing Division for questions about specific businesses: httns://www.ci.wheatridge.co.us/154/Business-Licensing Parking requirements in the MU -C zone district are dependent on use or business type and are enumerated in Section 26-1109 of the code. The property was developed prior to the MU -C zoning being in place, therefore the site and building design of the property and the parking counts are considered to be legally nonconforming relative to the current MU -C zoning. It is the intent of the code to permit legal nonconformities to continue until they are voluntarily removed, or until they are amortized, but not to encourage their survival. A nonconforming structure that has been involuntarily damaged in whole or in part by www.cimheattidge.co.us fire, flood, wind or other calamity may be restored to its original size and scope, provided such work is in compliance with applicable building codes and restoration work commences within six (6) months of the damage occurring. Refer to Sections 26-120 and Section 26-1103 of the Wheat Ridge Municipal Code regarding nonconformities. While it is difficult to ascertain if any violations are present on the site, it should be noted that currently there are no active code enforcement cases for the property. Please feel free to be in touch with any further questions. I can be reached by phone at (303) 235- 2845 or by email at lmikulak@ci.wheatridge.co.us. Sincerely, Lauren E. Mikulak, AICP Planning Manager i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: N 1 R- ► 1 j ,, a Job Address: -7 1 S^ ter n 'A t -e - 1S - Permit Number: / q o 3 `� i 1) 1, 1 _ "na7,-%, 1-) 0� ) P cXr�, Ot ) ��h CGi'��C3DLG�- tti� 'c Dn 4, ons ❑ No one available for inspection: Time G:- Lf 1 CM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: - -Fh DO NOT REMOVE THIS NOTICE qq� 10-1)- i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: /-166 _EL Job Address: % w 39tV/n A14/5- Permit Number: ❑ No one available for inspection- Time AM/PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: ' it Inspector: 00 NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3a9- Pn QL 5::),-c lq- aCle e f,11,11el Job Address: "7 (,iS-- Ave Permit Number: 'Q o 1 S D a S 3 ❑ No one available for inspection: TimeO.1 v/ M Re -Inspection required: Yes Q-) When corrections have been made, ca/ffor re -inspection at 303-234-5933 Dat _'; ectI p ll i Date Z-7 `� � ns o= i DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3✓0 de - Job Address: 7�l� W Permit Number: j ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes; No% When correct' ns have been made, call for re -inspection at 303-234-5933 Date: �( - Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 301 r K Job Address: 761,45' L/ .39 Permit Number: 2019015-31 ❑ No one available for inspection:. ime `;q ,�) AM/PM Re -Inspection required: Yes CNo When correct ons have been made, call for re-inspectio at 303-234-5933 Date: f f Inspector: i , ! r 60 NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 306 6t Job Address: ✓f Permit Number:i ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: 11 1V 1 J Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Comm. Tenant Finish PERMIT -201802863 PERMIT NO: 201802863 ISSUED: 10/31/2018 JOB ADDRESS: 7615 W 38th Ave Suite B-115 EXPIRES: 10/31/2019 JOB DESCRIPTION: Commercial tenant finish -modify one existing room to install a new X-ray machine. Drywall, flooring, and electrical work, no upgrade to panel. No mechanical or plumbing. 130 sq ft total Tenant: Touchstone Imaging *** CONTACTS *** OWNER (303)796-8288 SUB (303)341-7242 SUB (303)699-5848 DPC COMPANIES Charles W. Cullens Roger Binford 180003 Emerald 060118 Binford C.M., Inc Electric, LLC *** PARCEL INFO *** ZONE CODE: MU -C / Mixed Use Commercial USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 47,725.00 FEES Total Valuation 0.00 Plan Review Fee 459.26 Use Tax 1,002.23 Permit Fee 706.55 ** TOTAL ** 2,168.04 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. City of Wheat Ridge Comm. Tenant Finish PERMIT - 201802863 PERMIT NO: 201802863 ISSUED: 10/31/2018 JOB ADDRESS: 7615 W 38th Ave Suite B-115 EXPIRES: 10/31/2019 JOB DESCRIPTION: Commercial tenant finish -modify one existing room to install a new X-ray machine. Drywall, flooring, and electrical work, no upgrade to panel. No mechanical or plumbing. 130 sq ft total Tenant: Touchstone Imaging Is' nature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, ,Pb;aplicab 'Iding odes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the 1 gal 0n r the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this pe it. Iattest that I am legally authorized to include all entities named within this document as parties to the work to be perform d and at Iw to Pe pe�formed•is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER ok CONTRACT9k (Circle one) Date 1. This permit was issued ba tifbrmation provided in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The !issuance or granting of a permit sh ll not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any�inance or regpVtion of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of ].` �Cn"M, W heat�idge uNiTy DEVELOPMENT RECEIVED Building & Inspection Services 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 err Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: l Plan/Permit #� Plan Review Fe Email: permits6d�ci.wheatridge.co.us Z% , Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: W • 3U`--_� ()(1 4 s l S- I Q, A Property Owner (please print)-71DPC_ Q4# -_j Jess 7i ire. Phone: 3O.. _49 b 1 Property Owner Email: Tenant Name (Commercial Projects Only) I C-uG�S-�e ==�1 N C, Property Owner Mailing Address: (if different than property address) Address: �_Z� C—_7 , (2->e- t u t e- L,.-) au F_ "Su t.It- __3C1b , State, Zip: t-;( P v_nL,_xw -,.-4 \1 i t. u- \..-- C. -AD Architect/Engineer E-mail: JCS &'bau%%y--ncs arck Phone: �p3 • (� . ��,�,(� . C.o Inn Contractor Name: - YYl ,� C . A& . f -,7-,-\ c . City of Wheat Ridge License #: BCD(K C'hone: � - �� Contractor E-mail Address: 1 l'\ PU v For Plan Review Questions & Comments (please print): CONTACT NAME (please print): &C-1 S 61C\VW%i A{--1 Phone: 3 • 4-4op - OS -1 L{ CONTACT EMAIL(please print): Nrl --, • A)cA v%J A ti (O eevxc_rcJJ C w\. t n L • CD ^,,\ Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: P)% n Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City Licen7 4 &bolo � Other City Licensed Sub: City License # Other City Licensed Sub: City License # Complete all highlighted fields, if applicable. VCOMMERCIAL ❑ RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. �.j � C>( wc'.t� e- o r'K , —t'1--0- c 'l S Ino r�Ll�.c..�.�C CIO Sq. FULF I l Q BTUs N f a Gallons Ota Amps Squares For Solar: Kw # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: G Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) l,qt OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of ally entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) ( ON C OR or ( UTHORIZED REPRESENTATIVE) of (O{VNER) (CONTRACTOR) Signature (first and last ae):Q—� DATE: Printed Name: ImC 1 S 1O \ i ACS -C1 ZONING COMMMENTS: Reviewer: BUILDING DEPART T MMENTS Reviewer: 10 PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: 1� CONSTRUCTION TYPE: Y6 , " (� i)) e F LO LO ZS - Building Division Valuation: Address. Permit Application - Print Preview Addr/Street: 7615 West 38th Avenue City/State: Wheat Ridge CO Zip Code: 80033 rroperry owner: First Name: DPC Attn: Jess Dire Last Name: Business Name: Phone: (303) 796-8288 X3346 Phone AH: Cell Phone: Fax: Addr: 700 E Belleview Ave. Ste 300 Suite: City/State: Greenwood Village CO Zip Code: 80111 Email: Occupant: Building: Occupant: Touchstone Imaging (Space#1) Suite: 8115 Property Use Type: Commercial Job. Job Type: 2 Existing Building/ Tenant Improvement Sq Ft: 127.00 Cost: $47,720.00 Desc: Modify one room to install a new X -Ray Machine. Includes new drywall, flooring and electrical work. There is no mechanical work included in this project. Fire Sprinkler and Fire Alarm are anticipated to remain as -is Comments: Request SPR West Metro Fire Protection District 433 S. Aiiison Pkwy. Lakewood, CO 80226 em Phone: 303.989.4307 www-.westmetrofire.org West MCLCO Fire Rescue Tenant Finish/ Improvement Permit Application APPLICANT INFORMATION Company Name: Emerald C.M., Inc. Contact Person: Chris Atamian Project Name/Tenant: Touchstone Imaging - Room Alteration Project Address (Include Suite #): 7615 W. 38th Ave., Suite 13115 City: Wheat Ridge State: CO ZIP code: 80033 Phone: 303-472-0514 Email: chris.atamian@emeraldcminc.com Design Professional (if applicable): Jeff Jones Phone: 303-886-3860 Email: jeff@davisjonesarch.com PROJECT INFORMATION (CHECK ALL THAT APPLY) Occupancy ❑ A -_ )D( B ❑ E ❑ F - ❑ H-_ Classification(s): ❑ I -_ ❑ M ❑ R-_ ❑ S__ ❑ U Type of Building: ❑ New Building A Existing Building Fire Protection ❑ Fire ❑ Fire Detection ❑ Standpipe ❑ Kitchen Hood ❑ Other: Instal Systes to be Suppression System System EXisting Design Standard: ❑ 2009 IFC ❑ 2012 IFC ❑ 2015 IFC ❑ 2018 IFC Square Footage of Project: 127 SgFt Description of work/Scope of work: Modify one room to install a new X -Ray machine. Includes new drywall, flooring and electrical work. There is no mechanical work included. SUBMITTAL INFORMATION REQUIRED (NOT AN ALL-INCLUSIVE LIST) Construction plans and documents shall be complete and of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail compliance with the applicable codes, standards and amendments. 6h7 Electronic Plans to Scale - One Set Depicting Existing Conditions, Demolition Plan, and Proposed New Conditions Include Mechanical, Electrical & Plumbing Plans (MEP's) (Electrical Only) Written Scope of Work ❑ Full & Proper Code Analysis ❑ Life Safety/Egress & Exit Plan Q I, the applicant, verify that plans have been fully unlocked and unsecured at the time of plan submittal. DEFFERED SUBMITTALS/PERMITS SHALL BE REQUIRED FOR THE FOLLOWING WORK Fire Detection Systems Fire Suppression Systems Underground Fire Line Access Control Systems Medical Gas Systems Kitchen Hood Suppression System Emergency Responder/ Radio Amplification Systems Photovoltaic/Solar Power Systems BY SIGNING BELOW, I CERTIFY THAT: I have thoroughly read and understand all information on this Permit Application and that all information supplied is true and correct to the best of my knowledge. I understand that Construction Plans and Documents shall be complete and of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail compliance with the applicable codes, standards and amendments. If this is not the case, my plans may be rejected and a re -submittal fee may be assessed. Review and approval by the Fire Code Official shall not relieve the applicant of the responsibility of compliance with applicable codes, standards and amendments. **Both "Corrected" and "Revised" plans that are submitted for further review shall be placed back in the queue in the order they were received. They will no longer be given preference over newly submitted projects. Corrected and Revised plans could also be subject to additional fees.** Signature of Applicant: Date: 10/25/2018 Plan review comments and status regarding projects are available by logging in to your contractor portal at www.mobile-eyes.com/PA Index. asp?Submit= Logon . Oct -18 WC-Ity of heat�idge COMMUNITY DEVELOPMEN f SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 7615 W. 38th Ave Suite B115 Permit #: 201802863 General Contractor: Emerald C.m Inc Electrical Sub -Contractor Company Name: Binford Electric Phone #: 303-669-5848 State License #: 0003542 Wheat Ridge License #: 060118 Digitally signed by Roger Binford Roger Binford ou, a DN:cn Binford, foBinford Electric, LLC, mail=rbinford@binfordele<tric<om, USDate: 2018.10.28 12:24:27 -06'00' Signature of Authorized Agent Plumbing Sub -Contractor Company Name: State License #: Wheat Ridge License #: Signature of Authorized Agent Mechanical Contractor Master #: 0003829 (required field) 10/28/18 Date Phone #: Master #• _(required field) Date Company Name: N/A Phone: Wheat Ridge License #: Signature of Authorized Agent (required field) Date *evkwed to► Zen ft Compt by t1* %%4* City of s4!Ggat Wheat Ridge FUnnftV•� APPR we. OATS: REC. NO. F1780527 UNPLATTED � I PARCEL NO. 3423304027 OWNER: VAN E CARVER REC. NO. 29WO576 DATED 21&1977 iS00°OS'43"W UNPLATTED SEE SHEET 3 I I � I w a 7 Z N C PARCEL NO. 39 -MM -038 LL WOOD FEN OWNER: 302 POPLAR LLC f .0.5' W. al PARCEL NO. 34233•W-033 I REC. NO. F180B6B6 A 8 8 OWNER ROGER P LOECHER I UNPLATTED WOOD O EFENC Z ?, Q INVESTMENTS INTERNATIONAL REC. NO. F0770255 N. OF PROPERTY r BUILDING I UNPLATTED I _H LINE E -0H u ONES, -�H� -OH HL-- BLOCK B, Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. LEGAL DESCRIPTION REAL PROPERTY IN THE COUNTY OF JEFFERSON, STATE OF COLORADO, DESCRIBED AS FOLLOWS: LOT 1, BLOCK 1, THE WILMORE CENTER, COUNTY OF JEFFERSON, STATE OF COLORADO. THE PROPERTY HEREON DESCRIBED IS THE SAME AS THE PERTINENT PROPERTY AS DESCRIBED IN FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL SERVICES FORECLOSURE GUARANTEE ORDER NUMBER NCS -530714 -CO, EFFECTIVE DATE FEBRUARY 22, 2012. THE PROPERTY HEREON DESCRIBED IS THE SAME AS THE PERTINENT PROPERTY AS DESCRIBED IN ZODIAC TITLE SERVICES LLC DATE DOWN LETTER ORDER NUMBER 100562, DATED OCTOBER 28, 2011. THE PROPERTY HEREON DESCRIBED IS THE SAME AS THE PERTINENT PROPERTY AS DESCRIBED IN CHICAGO TITLE INSURANCE COMPANY POUCY NUMBER 72107-2349546. HAVING AN EFFECTIVE DATE OF APRIL 6, 2005. T P!1 PITT\ • SET NO.5 REBAR AND 125° YARD SEix(#U9�ED BY ADJACENTPROPERTY HL ^`- 11489.6T09"E 11 300. O'M8P # a NAIL 8 BRASS WASHER PLS 37829 CONC. CONCRETE o MONUMENT FOUND AS NOTED R,O.W, PLS RIGHT OF WAV PROFESSIONAL LAND SURVEYOR CONCRETE NO. -BUILDING CORNER - 05W. OF PROPERTY UNE HANDICAP PARKING SQ. FT, SQ. SQUARE FEET 4 w . + TRASH ENCL WOOD FENCE ASPHALT I& 18A• ASPHALT W000 FENCE MiErl'V EASEMENT - - - - - -281` - B L ~ - 6 - CONCRETE PAN -SIGN ❑T TELEPHONE PEDESTAL m a O CHAINUNK FENCE Off' \ CENTECTRIC (P) PER PLAT OF 'THE WR' FL -FL ELECTRIC VAULT RIC ELEILMORE FLOW LINE TO FLOW LINE BFp W, i B B__BEGNO�60D915i-__--___-_, _ - - _ F _F�F.165.3'.1 • _ _ �� 9� PARCEL N0.3423340/1 TPo TRAFFIC CONTROL BOX EM I i E - 165.3' EBOX � 2 OWNER C&D INVESTMENTS LLC ` f REC. NO. 2007133307 I V UNPLATTED 0 a m OVERHANG INLET a GARAGE CORNER 9 20.0 _ U i -0.7 N. OF PROPERTY UNE GRAPHIC SCALE -I' = 30' ,. 184.4' TOP BACK OF CURB d0� "( • 0.6' S. OF PROPERTY COLUM0. C1°/P) OVERHANG \ .o LINE Zia O T> U N89'5TO9'E 175.00' M&P CONCRETE CURB I 55' -y VIE p e � �a0 v;. FRAME OVERHANG= FOUND NO. 5REBAR '.�F) 0.55.OF PROPERTY LINE - U ASPHALT O0 S / GARAGE CORNER •O.T E.802 N. F PROPERTY ASPHALT OCRETE CURB O O' < J I Nm 7 It. LINES O Z Ia # OINLE \ J = a 3 IIR /- -]INLET \ 01 1 $ O U ED Ir � Un01 r y T W d O� 0 j ASPHALT PLASTIC AP PLASTIC CAP ASPHALT X = co O_' Q co a p9 '' F PLS 9010 w_ O N^ N 2!(.5' g coo W_ (J TRASH CONCRETE CURB ¢ I uJ ❑ 140.30' g 0 I3 - C6LUMN` (T'P) I\S89°5613'W 3� BUILDNG ONE STORY BRICK W179.0 JENCLI3 ICER of BUILDINGINLET .'SO4 PROPERTY I LINE 8 UILOIpZ I I w FL -FL 87.T CORNER I 2 W - PROPERTY a w f .B 1- B UZ p #7615 W. 38TH AVENUE O LINE g 2Vo HI B o k r '.B d _ O 1 STORY STUCCO BUILDING 719.735 SQUARE FEET b I B. PARCEL NO. 34233-00048 ❑3 5 O HEIGHT a 183.7' m) _ OWNER: 3815 WADSWORTH LLC I O m A ++ < (0 < W PEC. NO. F0791082 r _ O l UNPLATTEO T I p < < V ZZ TIOTO DETERMINE t'1 END CONCRETE I O I 6 ❑ P71IZIN�HEIGHT Td❑ Uj j // W 179.6' ___----_--- LOCATION TO J w A p - -- _ ,_ 43.0' r DETERMINE BUILDING HEIGHT O r PARCEL NO. 39.233.06047 a. U Q CONCRETE CURB ] OWNER SG HOLDINGS LLC REC. NO. 2010011814 . d jj �p A b J TOO _ E. SIDE CONCRETE UNPLATTED Wµ -OZEOF - - - ASPHALT - PROPERTY UNE I C, TRASH EO 176- .I ENCL �_ I 0 e J TOPBACK � 30.T O 64.R iPDICu E.CURS .2.0 W. OF E RiOPERry UNE CONCRETE CURB L rya m 5.5' X Z SIGN HEIGHT -17.31 CONCRET FOUND 1.5" YELLOW PLASTIC CAP IRRIGATION D 11' X 1' SIGN EQUIPMENT HE .0' owi qa u m w 0 54.7' 77 8' UTILITY EASEMENT Ih ASPHALT REC NO. 86009155 LI PLS 9070 FOUND 1.5" YELLOW PLASTIC CAP m J w37nam PLS 9010] -' Z ry w ACCESS _ ®_ _ TOP aACIc WCURB LL Q�2gmg< tl L. _ l 13 W. .1 E. PROPERTY LINE 120"03'4T'E- _. - _ - ----_____ ._ _ J �Noo°osaT"E CRETE CURB WEST 38TH AVENUE (R.O.W. VARIES) PAVED/PUBLIC) 6'%28'UTILTTYY/ �) Ia UTILITY EASEMENT (TEE Sgg•58'131N 3290(TIE) (ASPHALT u7ILr1Y EASEMENT FL -FL REC No. e6a691ss ( ) 1972.33'(M8P)_ - (WbP) S89 °58'13'W REC. NO. 91025423 68.1' 462.15'(M&P) - S8 '56'13'W 195.30'(M8P) - - _ _ _ _ _ _ _ - L- a S89°56'13'W S. LINE SW1/4 SEC. 23, T.3S., R.69W., 6TH P.M. (BASIS OF BEARINGS) _ _ _ - - _ _ _ _ _ _ - _ 2629.7W(M&P) _ S1/4 CORNER SEC. 23 LOCATION OF WILMORE SIGNAGE T.3S-, R69W., 6TH P.M, FOUND 325" BRASS CONCRETE CURB CAP IN RANGE BOX LEGAL DESCRIPTION REAL PROPERTY IN THE COUNTY OF JEFFERSON, STATE OF COLORADO, DESCRIBED AS FOLLOWS: LOT 1, BLOCK 1, THE WILMORE CENTER, COUNTY OF JEFFERSON, STATE OF COLORADO. THE PROPERTY HEREON DESCRIBED IS THE SAME AS THE PERTINENT PROPERTY AS DESCRIBED IN FIRST AMERICAN TITLE INSURANCE COMPANY NATIONAL COMMERCIAL SERVICES FORECLOSURE GUARANTEE ORDER NUMBER NCS -530714 -CO, EFFECTIVE DATE FEBRUARY 22, 2012. THE PROPERTY HEREON DESCRIBED IS THE SAME AS THE PERTINENT PROPERTY AS DESCRIBED IN ZODIAC TITLE SERVICES LLC DATE DOWN LETTER ORDER NUMBER 100562, DATED OCTOBER 28, 2011. THE PROPERTY HEREON DESCRIBED IS THE SAME AS THE PERTINENT PROPERTY AS DESCRIBED IN CHICAGO TITLE INSURANCE COMPANY POUCY NUMBER 72107-2349546. HAVING AN EFFECTIVE DATE OF APRIL 6, 2005. T P!1 PITT\ • SET NO.5 REBAR AND 125° GM. GAS METER YELLOW PLASTIC CAP OR # LIGHT POLE NAIL 8 BRASS WASHER PLS 37829 CONC. CONCRETE o MONUMENT FOUND AS NOTED R,O.W, PLS RIGHT OF WAV PROFESSIONAL LAND SURVEYOR CONCRETE NO. RECEPTION NUMBER HANDICAP PARKING SQ. FT, SQ. SQUARE FEET ® WATER MANHOLE Di TELEPHONE MANHOLE YJ FIRE HYDRANT ENCL. ENCLOSURE -SIGN ❑T TELEPHONE PEDESTAL B. BOLLARD O SEWER MANHOLE SANEV (M) AS MEASURED CENTECTRIC (P) PER PLAT OF 'THE WR' FL -FL ELECTRIC VAULT RIC ELEILMORE FLOW LINE TO FLOW LINE To TELEPHONE PEDESTAL TO TELEPHONE PULL BOX `d POWER POLE TR TRANSFORMER EB ELECTRIC BOX TPo TRAFFIC CONTROL BOX EM ELECTRIC METER CT CABLE TV BOX E ELECTRIC VAULT WATER METER �,P TYPICALWM �- GUY ANCHOR This is to certify that this map or plat and the survey on which it is based were made In accordanr:F 0th the 2011 Minimum Standarc Detail Requirements for ALTA/ACSA1 Land Title Surveys, jointly established and adopted by ALTA and NSPS, and includes Items 3, 4, 6(b), 7(a), 7(b)(1), 7(c), 8, 9, 11(a), 13, 14. 16, 17 and 18 of 1 A thereof. The field work was completed on April 23, 2012. SHEET TITLE SURVEYED BY: ALTA/ACSM LAND TITLE SURVEY a PROJECT WILMORE CENTER 0 @@i a 14 C 7615 & 7777 WEST 38TH AVENUE WHEAT RIDGE, COLORADO 80033 ""„�'at La�to,...,,`°• `Colorado P.L.S. k ?7929 This is to certify that this map or plat and the survey on which it is based were made In accordanr:F 0th the 2011 Minimum Standarc Detail Requirements for ALTA/ACSA1 Land Title Surveys, jointly established and adopted by ALTA and NSPS, and includes Items 3, 4, 6(b), 7(a), 7(b)(1), 7(c), 8, 9, 11(a), 13, 14. 16, 17 and 18 of 1 A thereof. The field work was completed on April 23, 2012. COORDINA"ED BY: OLD REPUBLIC � .T Css 17330 Preston Road, Suite 150A Dallas, Texas 75252 P:(469) 737-7000 F:(469) 737-7070 DRANK BY: ROG / CRY CHECKED BY: RBC COPYRIGHTU2011, OLD REPUBUC SITE MANAGEMENT SERVICES. ALL RIGHT RESERVED. /7 Date of Plato; Map: April 23, 2, 2 '=-ss .,.•• Richard B. Cabk.l ""„�'at La�to,...,,`°• `Colorado P.L.S. k ?7929 COORDINA"ED BY: OLD REPUBLIC � .T Css 17330 Preston Road, Suite 150A Dallas, Texas 75252 P:(469) 737-7000 F:(469) 737-7070 DRANK BY: ROG / CRY CHECKED BY: RBC COPYRIGHTU2011, OLD REPUBUC SITE MANAGEMENT SERVICES. ALL RIGHT RESERVED. f 00 N R y O w 2 M y 'p N d N 00 r a r \06 � O � V U3 U R OD Q C z a ai a> 00o U :j U N y b0 i W A Cv b 4) sflO i Mo co � F a. W 41 R.o �p W v \I/ 4J en 14 d 3 v .:) C 0 H W tn O > o L d C ~ ¢CD a .o o O a b OwiO v, �r Cc 4.).b V 4J Ci 44 N I�z x ccQ 3V� bb� U V u 0 3 riaA� w �tU a � O c O cjY v. 3O0 b W U ri a� 0 U E+ O l� y ay fM�� Ujp� rA d a O .Ci w° d O A M O O R y F. Q N b 44 0 0 ,1 c = E c H k o N 4.)d a) a E a zzaUF" v m 3oae0 '00 R a U y C a F a:: OUaaGz.z a i City of �7�Theat idle BUSINESS LICENSE INSPECTION PERMIT NO. 201801687 BUSINESS NAME: Hangar, Inc. INSPECTION DAY/TIME Wed., June 13th @10:00 AM INSPECTION DAY/TIME- zo ' INSPECTION DAY/TIME Zo: ADDRESS: 7615 W. 38th Avenue, Suite B111 CONTACT NAME: John Or Erin J SQ FT OCCUPANCY TYPE OCCUPANCY LOAD CONSTRUCTION TYPE ❑ SPR LERED NON-SPRINKLERED -1-3 /e, Date O b w O Q QCon mm n rr m nm Pi arr xr"� itJ It °e c `C N• a ~rra° O r, '0�0 � o C'ti t-j! �d�O�, m t 00 R m �N mo p 01 n O H m 0 C N CD m c c ►° wm L?JZ00 O rr H rQ � 4 � "m° m CID CID Cr" 3 I a 5 n baa w mamro� o L`7 M W `.1 0 cy Z� [�7 .Jm O �' �G g /� � l V l��I tIj 'R� �� �� oPo W w a 00 b7a yes o O p re H c:Po o eb Cr oc y z b 9W m H m IV O fD O b wO W H- a H 0 � "� C v0, �• G o ^ mPU t"h c co m 1 n rr w m e m O y ' fD O n ~"LlC O a :r M M by E. n� O c do. A FL G7 ua a �0 r CD \ 1 0 V O O o G b p rr C O G ? R e' n ac 0 O O CD n w % 00 C) Pr a F � o ft 00 �� tOf l Wl�iyeatidge BUSINESS LICENSE INSPECTION PERMIT NO. 201801648 INSPECTION DAY/TIME Tues., June 12th @ 11:00 AM INSPECTION DAY/TIME f/�. %e"' _ 6 INSPECTION DAY/TIME �/ ' Ln� BUSINESS NAME: Touchtone Imaging, LLC ADDRESS: 7615 W. 38th Avenue, #13-107 CONTACT NAME: SQ FT OCCUPANCY TYPE OCCUPANCYLOAD CONSTRUCTION TYPE JB ❑ SPRI D NON- SPRINKLEREDD Inspector Si&dure Date i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ,64Z — J7�/ �f f; zsf-h epi � s Job Address: l S /[i 3aA-e - /ll Permit Number: ® I O /, Fr % ❑ No one available for inspection: TimeAMS M Re -Inspection required: Yes N0 When corrections have been made, call for re -inspection att3,033-234-5933 Date: '/.3'i(F Inspector: >/ DO NOT REMOVE THIS NOTICE t 4' CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax ECTION NOTICE Inspection Type: Job Address: Permit Number:/ ❑ No one available for inspection: Time - M q Yes Re -Inspection required: �N When corrections have been made, call for re -inspection at 303-234-5933 Date: ` %r Inspector: )eIV45-1 / T DO NOT REMOVE THIS NOT/CE e A i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 'ZEl Job Address: Permit Number: ❑ No one available for inspection: Time j1,&_AI��F'ivy Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Dater 111 Z Inspector: DO NOT REMOVE THIS NOTICE 55b� 303 — )/0 — /r�.3 s i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: S Job Address: ?GIa) R-115 Permit Number: �,!�19/,Q FUT Zoel1 y dei, ❑ No one available for inspection: Time AP Re -Inspection required: Yes Nom When corrections have been made, call for re -inspection at 303 -234 - Date: • !f. /517 Inspector: �l DO NOT NOT REMOVE THIS NOTICE 55b� 303 — )/0 — /r�.3 s i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: S Job Address: ?GIa) R-115 Permit Number: �,!�19/,Q FUT Zoel1 y dei, ❑ No one available for inspection: Time AP Re -Inspection required: Yes Nom When corrections have been made, call for re -inspection at 303 -234 - Date: • !f. /517 Inspector: �l DO NOT NOT REMOVE THIS NOTICE CER TIFICA TE OF COMPLETION Permit #: 201709682 1." City of Date: 04/19/2018 � Wheatpidge COMMUNITY DEVELOPMENT 7500 W 29TH AVE WHEAT RIDGE CO 80033-8001 *Stipulations: Commercial T/I 2770saft. Proposed use -Medical Imaging Clinic equipment includes mammography and PET CT equipment. This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code, Zoning and other related land use and development laws of the City of Wheat Ridge, and may be occupied for the use specified. OWNER: WILMORE 38, LLC ADDRESS: TOUCHSTONE MEDICAL IMAGING / 7000 E Belleview AVE 300, Greenwood Cillage CONTRACTOR/ADDRESS: Jeff Nading 700 Weaver Park RD, Longmont, CO 80501 PROPERTY ADDRESS: 7615 W 38th AVE SUITE B105, Wheat Ridge, CO 80033 PARCEL #: 39-233-21-030 OCCUPANCY: B TYPE OF CONST: II -B OCC LOAD: NA FOR THE FOLLOWING PURPOSE: Comm. Tenant Finish Code Editions: No change shall be made in the Use of this building without Sorinklered: 2012 ICC / 2014 NEC prior notice and a new CERTIFICATE OF COMPLETION No from the City of Wheat Ridge A. Chief Building Official INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following '� business da PERMIT: I � ADDRESS: r JOB COD7 Iy Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 302 Wall Sheathing 103 Footing / P.E. Letter _My 104 Foundation Setback Cert. 305 Insulation% 105 Stem Walls 306 Mid -Roof 106 Foundation wall Insulation 307 Metal / Lath / Stucco Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 302 Wall Sheathing 202 Sewer Underground Int. _My 203 Sewer Underground Ext. 305 Insulation% 204 Plumbing Underground Int. 306 Mid -Roof 205 Plumbing Underground Ext. 307 Metal / Lath / Stucco 206 Water Underground 309 Rough Electrical Commercial Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing ., x 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation% l Z % I r✓ 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS 17 qiC-J�) �n ADDRESS�n�1��,,� ,�l inB CEDE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 7 > 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 14 322 Rough Grading 1 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 14 408 Final Plumbing Commercial 1 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 *For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** L-1 - )$' t�r L+--T-SMti 415 Public Works Final** Al Storm Water Mgmt.** 4-,7 Zoning Final Inspection* 413 Building Final InspectionV 'W Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. oro a OY77n0 a� CD rt N n m m f7 y A ti 0 art � r• � PoC 5 �k N no o rt "Im n O w d d 0t!r brt �jd� zo�z0 "C p �� O O H A H ~ •• T On O Irl A �y O C R = C ��J M 00 � m > � '� p a y< cn .o c ort ►� 17 an CD p a n x mam CD o C ay N M W 0 '.y m lQ N CsJ m R cG�? ewe y y p V H w IQ OP o eas � ooh � ►r • _ J w mHm n0 t ��c O rt Z 00 CD � � U.) r- ton F3 rr cu �. C> n "a n �- a o o arr o o a m n d 5 p: � y �• yb z Q - CD °Q a � CD °' rt o n o n CL c IN rt > G f. tv Q v fD H C O 10 O Q ° ee o pr '! R a o O. O pp I CCD i' i i PERMIT NO. 201801038 (Jty 0f := Wheai W-dge BUSINESS LICENSE INSPECTION INSPECTION DAY,/TIME Wed. ed • April 18th INSPECTION DAY/TIM INSPECTION DAY/TIM BUSINESS NAME: Touchstone Medical Imaging LLC ADDRESS: 7615 W. 38th Ave. Suite B-105 CONTACT NAME: LOralee 7O SQ FT OCCUPANCY TYPE OCCUPANCYLOAD I/-6 CONSTRUCTION TYPE ❑ SPRINKLERED NON-SPRINKLERED Ins L CHRISTOPHER MENGES ENGINEERING, INC. MECHANICAL & PLUMBING CONSULTING ENGINEERS April 10, 2018 Jay Scheiner Golden Triangle Construction 700 Weaver Park Road Longmont, Colorado 80501 RE: Touchstone Imaging 7615 W. 38th Ave., Suite B105 Wheat Ridge, Colorado 80033 The intent of this memo is to provide clarification regarding return air plenum at the Touchstone Imaging suite in Wheat Ridge. Since the unfinished portion of the space will be conditioned by the existing RTU, the plenum space above the imaging suite is not required to be isolated from this area. Therefore, the walls between the imaging suite and the unfinished space do not need to extend to the bottom of the roof deck. Since ely, V , Jeff Bellman, P.E. CHRISTOPHER MENGES ENGINEERING, INC. 1100 W. LITTLETON BLVD., SUITE 400, LITTLETON, COLORADO 80120 (720) 283-3018 PHONE, (720) 283-6253 FAX WWW.MENGESENG.COM i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: '7 Job Address: 79/ h d Permit Number: ,/moi ❑ No one available for inspection: Time /3Ct7AM/PM Re -Inspection required: Yes When correct' ns ve been made, call for re -inspection at 303-234- Date:- / a / Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge 01 Comm. Tenant Finish PERMIT - 201709682 PERMIT NO: 201709682 ISSUED: 02/15/2018 JOB ADDRESS: 7615 W 38th AVE SUITE B105 EXPIRES: 02/15/2019 JOB DESCRIPTION: Commercial T/I 2770sgft. Proposed use -Medical Imaging Clinic equipment includes mammography and PET CT equipment. **REVISION: Reduction in scope of work to eliminate rooms related to the PET CT, including the change rooms, procedure room, hot lab, hot r.r., and control room; unfinished space will be used for storage; reducing scope of work by 900 sq ft *** CONTACTS *** OWNER (303)905-9700 WILMORE 38, LLC GC (303)772-5051 Jeff Nading 160247 Golden Triangle Construction SUB (303)761-1211 Ross Whitesec 140018 Master Blaster Plumbing SUB (303)936-7924 Brad Christianson 080241 Rych Electric Inc SUB (970)506-0012 Joe Strangle 180039 Air Experts *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 403,672.00 FEES Total Valuation 0.00 Plan Review Fee 2,010.35 Use Tax 8,477.11 Permit Fee 3,092.45 ** TOTAL ** 13,579.91 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. All roughs to be done at Framing Inspection. City of Wheat Ridge Comm. Tenant Finish PERMIT - 201709682 PERMIT NO: 201709682 ISSUED: 02/15/2018 JOB ADDRESS: 7615 W 38th AVE SUITE B105 EXPIRES: 02/15/2019 JOB DESCRIPTION: Commercial T/I 2770sgft. Proposed use -Medical Imaging Clinic equipment includes mammography and PET CT equipment. **REVISION: Reduction in scope of work to eliminate rooms related to the PET CT, including the change rooms, procedure room, hot lab, hot r.r., and control room; unfinished space will be used for storage; reducing scope of work by 900 sq ft I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this erm►t. I rther attest that I am leg�ally authorized to include all entities named within this document as parties to the work to be performed an at all work to be rformed is disclosed in this document and/or its' accompanying approved plans and specifications. !-/-/3-1 Signature of 'O'NNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or aordmance or aulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat jjdge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(-ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Add to Permit # r Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** PropertyAddress: Lj.1 �� QCs�pe+Owner (please print): I hone: Property Owner Email: Mailing ( Address: (if different than property address) Address: 1007 f--- (! 0A �� f�yV , State, Zip: Contact Person: Contractor: Contractors City License #: Contractor E-mail Address: Phone: Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: Amk V,e � AuAiu,, 1� XNW�.'c'p �O' c c�ns�prMravry vbvm, rr7r �rXJ� �o� �•� av 1 frd v�ssm. Pvca,, M,Y-.P dw� a+� �rov�d<LI Sq. Ft./LF j '-/C/ S Lt�41"W Amps Squares Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) o AUTHORIZED PRINT NAME: � SIGNATURE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received Water District ❑ Received Sanitation District ❑ Received DEPARTMENT USE Y of (OWNER) (CONTRACTOR) DATE: v • 44L/n' E OCCUPANCY CLASSIFICATION: ❑ Not Required ❑ Not Required ❑ Not Required Building Division Valuation: $ A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: y0 FFG y06 1- M C- F)G Job Address: 7615 W� -3 00t" �'�e S J E 6 to Permit Number: aD /70 0/ 6 LY a- ❑ No one available for inspection: ime AM/PM Re -Inspection required: Yes N When corrections have been made, call for re -inspection at 303-234-5933 n Date:� � %8 Inspector: y� DO NOT REMOVE THIS NOTICE City of Wheat Ridge -y= Commercial Sign PERMIT - 201800833 PERMIT NO: 201800833 ISSUED: 04/16/2018 JOB ADDRESS: 7615 W 38th AVE SUITE B-115 EXPIRES: 04/16/2019 JOB DESCRIPTION: Commercial Sign - set of illuminated pan channel letters on a race way; 45.85 sq ft Tenant: Touchstone Imaging *** CONTACTS *** OWNER (303)796-8288 DPC COMPANIES SUB (303)975-1772 Robb Walker 018134 Advantage Sign Co. SUB Brad Christianson 080241 Rych Electric Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,770.00 FEES Total Valuation 0.00 Plan Review Fee 91.59 Use Tax 121.17 Permit Fee 140.90 ** TOTAL ** 353.66 *** COMMENTS *** *** CONDITIONS *** Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Note: This statement is inclusive of lease lines and storefront width. All lighting shall be in conformance with Section 26-503 of the Zoning and Development Code with fixtures fully shielded so that the source of the illumination is not visible from adjacent properties and streets. City of Wheat Ridge � a, Y' Commercial Sign PERMIT - 201800833 d PERMIT NO: 201800833 ISSUED: JOB ADDRESS: 7615 W 38th AVE SUITE B-115 EXPIRES: JOB DESCRIPTION: Commercial Sign - set of illuminated pan channel 45.85 sq ft Tenant: Touchstone Imaging 04/16/2018 04/16/2019 letters on a race way; re, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; in codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized Lec,of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with th r attest that I ala authorized tpancIude all entities named within this document as parties to the work to be hit all work to he perrcdjs disclo'at d ih this document and/or its' accompanying approved plans and specifications. Signature of OWNER or';/CONTRACTOR (Circle one) Date ` I _ This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 1 If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change. of the natural flow of water without prior and specific approval. 5. The pen -nit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a plermit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable cgpk gr any ordmaitl or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City o#' wheat is � t:C?:i'sr19L7'�Ii`r1' ���'►�Lf7t';�#F;�'T Building & Inspection Services Division 7500 W. 29"1 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 M� Inspection Line: 303-234-5933 Email: permit ci.wheatridae.eo.us ' FOR OFFICE USE ONLY �, Date: _ l I In Plan/Permit #) /c Plan Review Fee: Building Permit Application Please complete all hightighted areas on bath sides of this form. incomplete applications may not be processed. 7615 W 38th Avenue Suite B-115 Property Address: �cw�Skit'E�, 7Y4141mp irk hz Property Owner (please print}: 1 t� Z ,, , Phone: &03 Property Owner Email: d , ,tea nU Mailing Address: (if different than property address) Address: +b6c) LJ�z-x $oo City, State, Zip: Co M-11 ArrhitectlEngineer: NA Architect/Engineer E-mail: N�P' Phone: WN Contractor: Advantage Sign Company Contractors City License #: b k6�'5 ►.t phone: 303-975-1772 Contractor E-mail Address:e"i�hc��}iaYAnfg9�CS�`j�C`O�ttotiny.CD►+'1 For Plan Review Questions & Comments (please print): CONTACT NAME (please print): H e li�A c e- f Phone: 3 03 - 12 s- 17).2 CONTACT EMAIL(piease print}: Sub Contractors: Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W. R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # C) .� Complete all information on BOTH sides of this form 2COMMERCIAL [I RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION RESIDENTIAL ROOFING [] RESDENTIAL ADDITION H WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEMIAPPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT [I ELECTRICAL SYSTEM]APPLIANCE REPAIR or REPLACEMENT Ld�OTHER (Describe) Si (For ALL projects, please provide a detailed escription of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) i94?ftv4%,_ Q. Sq. Ft./LF Amps Btu's tftYI�5 ' L17 Gallons Squares other Project Value:. (Contract value or the cost of all materials and labor included in the entire project) — old OWNERlCONT&-kCTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) CONTRACTo S//�/J/,►Jr (A TH �yZ(p;ED REPRESENTATIVE) Signature (first and last name): DEPARTMENT USE ONLY ZONING COMMMENTS: Reviewer. SUIL2A ),,,,it.1 DEPARTMENT COMMENTS: Reviewer: 4 L/s/Z/l Y of (OWNER) (7CONMICTOR) DATE: 3 fL 1 i OCCUPANCY CLASSIFICATION: U_ Building Division Valuation: $ -7 0 Wall Sinn Calculation Sheet You must complete this sheet and include it in the submittal package for any new wall signs. You will also need to create a site plan and a detail sheet of the signage. Project Address: 7b 1S Contractor: 1U 1/y^fi4 5e 5!5#1 con / You are allowed 1 square foot of signage for every 1 linear foot of wail to which you are attaching a sign. All wall signs must be adjacent to a street or major interior drive. Step 1: Measure the length of the wall(s) where you are attaching the sign: Wall 1 - �� feet Wall 2 - feet Wall 3 - feet Step 2: The length of the wall is the allowable square footage for the wall sign. Wall 1 allowable signage- �(0 square feet Wall 2 allowable signage- square feet Reviewed for zoning compliance by the �► Wall 3 allowable signage- square feet City of Wheat Ridge Planning Division Site Plan APPROVED Se+- A4-144 - By. 2wOL^ ILJ . 3&- A o -e- DATE: 3 COMMENTS: City Of Wat heMidge OMMUN[TY DEVELOPMENT Section 26-503. — Exterior Lighting. A. Purpose. The purpose of this section is to regulate the spillover of light and glare from exterior lighting on operators of motor vehicles, pedestrians and land uses in the proximity of the light source. With respect to motor vehicles in particular, safety considerations form the basis of these regulations. In other cases, both the nuisance and hazard aspects of glare, reflected light and incidental spillover light are regulated. This section does not apply to public street lighting or to public outdoor parks and recreation uses. B. Permit required. An electrical permit application shall be required and a permit issued prior to installation or substantial modification of any exterior lighting. The permit application shall be accompanied by information required by the uniform electrical code and additional information that may be necessary to determine potential negative effects upon adjacent properties and public streets including, but not limited to, a plot plan showing location and orientation of lighting standards, building elevations showing location and orientation of lighting standards, lighting standard specifications including height, type (i.e., cutoff, non - cutoff, spot, floodlight, etc.), peak candlepower diagram, and any shielding devices to be incorporated so as to minimize incidental light spillover or glare. C. Lighting standards. The following restrictions shall apply to outdoor light control, including lighting within or directed upon outdoor signs: All fixtures shall be fully shielded. For purposes of this section, fully shielded shall mean fixtures constructed so that light rays emitted are projected below, and not above, the horizontal plane of the fixture, such that the source of illumination (bulb or direct lamp) is not visible from adjacent property or rights-of-way. All light fixtures shall be downcast to minimize undesirable effects of illumination such as glare, skyglow and light pollution. 2. All metal halide and fluorescent fixtures shall be filtered with glass, acrylic or translucent enclosures. 3. Only high-pressure sodium (HPS), low pressure sodium (LPS) or incandescent fixtures shall be permitted in commercial and multifamily residential parking areas. The level of illumination shall be consistent with minimum industry standards adopted by the illuminating engineering society. 4. All exterior lighting shall be designed and situated so that substantially all of the directly emitted light falls within the property boundaries. 5. Exterior lighting shall also be designed and situated so that no incidental or reflected light interferes with reasonable enjoyment of adjacent land uses, or safe movement of motor vehicles on public streets. 6. The following exterior lighting is specifically prohibited: a. Any light that may be confused with or construed as a traffic control device. b. Any animated, flashing or changing intensity lights, except for temporary holiday displays. 7. Lights one hundred (100) watts and less per fixture, fluorescent lights forty (40) watts and less per fixture, gas-fired fixtures and lights used for holiday decorations are exempt from the requirements of this section. 8. For commercial developments, mixed-use developments and multifamily residential developments, exterior freestanding light fixtures shall be mounted no more than eighteen (18) feet high. All other applications shall be limited to a maximum of twelve (12) feet. The height of a mounted lighting fixture shall not exceed the height of the wall it is mounted on. 9. Lighting plan. All applications for commercial, mixed use and multifamily residential developments shall submit, as part of the final site development approval, a lighting plan which includes the following: a. Site plan showing locations of all lighting fixtures and a numerical grid of lighting levels (photometric report) or as isoilluminance curves (concentric circular lines representing constant illumination levels). b. Lamp type and wattage. c. Mounting heights of all fixtures. d. Cut sheet showing the design and finishes of all fixtures and designation as cutoff fixtures. 10. Amortization schedule. All nonconforming outdoor light fixtures, including lighted outdoor signs, existing prior to December 1, 2000, shall be brought into conformance with these outdoor lighting provisions on or before December 1, 2005. Any light fixture that is replaced shall comply with the outdoor lighting regulations of this section at the time of such replacement. (Ord. No. 2001-1215, § 1, 2-26-01) 2 „ 5„ END VIEW Cit igvwl�fy All lighting shall be in conformance with Section 26-503 of the Zoning and Development Code with fixtures fully shielded so that the source of illumination is not visible from adjacent properties and streets. PROPOSED DAY CONDITIONS PROPOSED NIGHT CONDITIONS - � 40'-0" 227-5/8" 340" DE RPT N %d red —ILLUMINATED CHANNEL LETTERS - 5” DEEP PRE -FINISHED BLACK RETURNS -1" PRE -FINISHED BLACK TRIM CAPS - 3/16" WHITE ACRYLIC FACES - VINYL GRAPHICS APPLIED TO RIBBON LOGO - INTERNALLY LIT WITH WHITE PRISM LEDs - MOUNTED TO ALUMINUM RACEWAY ALUMINUM RACEWAY - 8" X 4-3/8" SIGNCOMP RACEWAY - PAINTED TO MATCH REVEAL IN WALL - RACEWAY WILL MOUNT IN 10" GAP REVEAL IN WALL FINISH SCHEDULE MP TO MATCH BUILDING 3M 230-108 PINK LAVENDER FONT CHAN GlWYAWAPGM tP$n$Q1r=NV to ti k A e City of Wheat Ridge PlaV" nnjng_aiyisi -� APPROVED 6Y:; FUTURE WORK, DO NOT INCLUDE IN PRICING E — I E --/-------------------------------- — ..i, 4 W I--------- -- -------------- --=�� ---�—-------------= —� 1 a 1 A B 1 L_— — ---- ej wo tJbr, or �►r� I ""'�wa�'�'��IMe�ar�ra�/wrtj4►o+nrs. �r POWER CENTERED HORIZONTALLY IN SIGN BAND OPENING �t►soVfthkolewmeftomwoomalr*CENTERED VERTICALLY IN EXISTING HORIZONTAL ORANGE ACCENT or otos" GrAWnces of the G shall not be val di ION ILLUMINATED CHANNEL LETTERS - ELEVATV//ION SQ FT. 45n85 SCALE. 3/8"=1'-O?' 2500 South Raritan, Englewood, CO 80110 (303) 975-1772 (888) 975-1772 TOUCHSTONE IMAGING 7615 W 38TH AVENUE SUITE B-115 WHEAT RIDGE, CO 80333 ILLUM. CHANNEL LETTERS CUSTOMER APPROVAL NAME: DATE: REV 09.12.17 TO 03.07.18 RR REV3 03.26.18 TO I REV4 E REV5 4 I REV6 REV7 REVS SALES: 1P PR: XX DESIGN: TO DATE: 08.21.17 DWG: 12958 These plans are the exclusive property of Walker Sign Holdings Inc. dba Advantage Sign and are the result of the original work of its employees. They are submitted to your company for the sole purpose of your consideration of whether to purchase these plans or to purchase from Walker Sign Holdings Inc. dba Advantage Sign A sign manufactured according to these plans, distribution or exhibition of these plans to anyone other than employees of your company, or use of these plans to construct a sign similar to the one embodied herein, is expressly prohibited and will render the user liable for damages. Copyright 2017 © Walker Sign Holdings Inc. All rights reserved. City ref U� ELECTRIC LOB SIG*heot Ridge PAGE: 0.1 Building Divi51®n uo u1 i t { + &.a�s�,.-.<s-�trar.st•nr��sr•, TT # f _ _ 1}YY`I�eStC���L�1 t Planning t-wr ATP I Ep �s �a. ...t��Fr: _+tel► - .rR — i° ' *rCOMMENTS: ;. �c�cky M�un►a�r� 60 Sir U " 7 0 caner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. SOT'C m 4m,^,t u&;o idtk NORTH F � f s HCl w f r _ low -J41 1 r .. 0 .G� "IRL OPP- i i' ' ` �► ar data 9;2018 Go0aie i i 1 F •, a- K . t. C077add 1 &Y" Westf38t► venup�... MIN. 3/4" PLYWOOD BLOCKING BY OTHER .040 PRE -FINISHED ALUMINUM RETURN TRIM CA 3/4" X 1/8" ALUM. HOLOBAR SPACER - CUT IN FIELD .050" PRE -FINISHED WHITE ALUMINUM BACK 3/8" X LAG BOLT INTO PLYWOOD BACKER BACKER BY OTHERS LEDs #WSW20 UL RATED SWITCH #1986 WI R EWAY COVER 3/16" ACRYLIC FACE .125 ALUMINUM RACEWAY BRACE #1982 TRANSFORMER RACEWAY - BACK #1981 TRANSFORMER RACEWAY - FRONT CLASS 3 LOW VOLTAGE WIRES TO LED DRIVER 3/8" GROMMET (SEALED W/ SILICONE) LED DRIVER (NOTE: ALL ELEC. COMPONENTS ELEVATED 1/2" MIN.) DRAIN HOLES (1) 1/4" HOLE PER 4' WIREWAY BREAK FORMED .090" ALUMINUM DRIVER BRACKET (MIN. 1/2" TALL) 6' MIN. SEALTITE CONDUIT W/ 3- 12 GA. WIRES (WHITE , BLACK & GREEN) THROUGH WALL - PENETRATION SEALED W/ SILICONE FINAL ELECTRICAL CONNECTION TWS RACEWAY MOUNTED CHANNEL LETTERS - TYP D W SCALE: NTS W)�-N100 rti-Ir ■ ■ ■�Ilia _■ rr'r � Y1 '■ • r■ ■'I ■ ■ ■,■■;■ rr'r rr�r- �ti r i on _11 ■ ■ •■ , ■ i 8 1 ■ r r,■r,■ ■ ■■■■ i .tib .. ■ •■•■ i ■ r ra■r;■ i'■'r ■,rr'i".%W) ■ r •r ■ 1 rr'r r�'■'-'�Yi i • • . ■. ■ r■■,■r�■ d -■'r �Y-�'d'� ' ■ an ■ ■ Now ■ No ■ rr■• i WALL THICKNESS IF KNOWN X" H t NO �.4���'IVVIAO NT,�4G�E� S I G N C O M P A N Y 2500 South Raritan, Englewood, CO 80110 (303) 975-1772 (888) 975-1772 TOUCHSTONE IMAGING 7615 W 38TH AVENUE SUITE B-115 WHEAT RIDGE, CO 80333 ILLUM. CHANNEL LETTERS CUSTOMER APPROVAL SALES: JP PR: XX DESIGN; TD DATE: 08.21.17 DWG: 12958 These plans are the exclusive property of Walker Sign Holdings Inc. dba Advantage Sign and are the result of the original work of its employees. They are submitted to your company for the sole purpose of your consideration of whether to purchase these plans or to purchase from Walker Sign Holdings Inc. dba Advantage Sign A sign manufactured according to these plans, distribution or exhibition of these plans to anyone other than employees of your company, or use of these plans to construct a sign similar to the one embodied herein, is expressly prohibited and will render the userAtEtUle for damages. Copyright 2017 0 \/ 1aIker Of Sign Holdings Inc. All rights reserved. Wh Rid U� ELECTRIC 9@ LISTED Sl"id rn9 Di PAGE: 0.1 Ey 09.12.17 TD REV; , 03.07.18 RR REVS 03.26.18 TD REV4 03.30.18 J1- SECTION REVS REV6 REVS REVS SALES: JP PR: XX DESIGN; TD DATE: 08.21.17 DWG: 12958 These plans are the exclusive property of Walker Sign Holdings Inc. dba Advantage Sign and are the result of the original work of its employees. They are submitted to your company for the sole purpose of your consideration of whether to purchase these plans or to purchase from Walker Sign Holdings Inc. dba Advantage Sign A sign manufactured according to these plans, distribution or exhibition of these plans to anyone other than employees of your company, or use of these plans to construct a sign similar to the one embodied herein, is expressly prohibited and will render the userAtEtUle for damages. Copyright 2017 0 \/ 1aIker Of Sign Holdings Inc. All rights reserved. Wh Rid U� ELECTRIC 9@ LISTED Sl"id rn9 Di PAGE: 0.1 i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NO ICE Inspection Type: �LE �d� Job Address: Permit Number: ,P-/a/70WI? ❑ No one available for inspection: Time AM/PM Re -Inspection required: esNo When c�orlrec "ons h ve been e, call for re -inspection at 303-234-5933 Date: 7 1 Inspector: XT—Y /V DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE 342qO Inspection Type: 3 G Job Address: 761 W �3r"" 4,,, Permit Number: rte/ %O 7j( No one available for inspection: TimeU7 %AM/PM Re -Inspection required:Yes No When corrections have been made, call for re --i—nspe�ct)ion at 303-234-5933 Date: q /() Inspector:/ iT DO NOT REMOVE THIS NOTICE Cn INSPECTION RECORD Inspection online form: http://www.cl.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspecti n the following business day PERMIT: ?ZI 9SW_3 ADDRESS: JOB CODE: Foundation Inspections Date Inspector Initials omments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT: �C� �Ct .ADDRESS: ���� [( �.�° " `E JOB CODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 401 Gasline 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof�- 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 'For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. CARLISLE GOLDEN SEAL TOTAL ROOFING SYSTEM WARRANTY SERIAL NO. 10158811 BUILDING OWNER: WILMORE 38, LLC P1*1 NAME OF BUILDING: WILMORE CENTER - 7615 BUILDING BUILDING ADDRESS: 7615 W. 38TH AVE., WHEAT RIDGE, CO DATE OF COMPLETION OF THE CARLISLE TOTAL ROOFING SYSTEM DATE OF ACCEPTANCE BY CARLISLE: 01/08/2018 DATE OF ISSUE: January 08, 2018 12/22/2017 (EB Warranty) CMD1232803 Carlisle Roofing Systems, Inc., (Carlisle) warrants to the Building Owner (Owner) of the above described building, that; subject to the terms, conditions, and limitations stated in this warranty, Carlisle will repair any leak in the Carlisle Golden Seal'Total Roofing System (Carlisle Total Roofing System) installed by a Carlisle Authorized Roofing applicator for a period of 15 years commencing with the date of Carlisle's acceptance of the Carlisle Total Roofing System installation. However, in no event shall Carlisle's obligations extend beyond 15.5 years subsequent to the date of substantial completion of the Carlisle Total Roofing System. See below for exact date of warranty expiration. The Carlisle Total Roofing System is defined as the following Carlisle brand materials: Membrane, Flashings, Adhesives and Sealants, Insulation, Cover Boards, Fasteners, Fastener Plates, Fastening Bars, Metal Work, Insulation Adhesives, and any other Carlisle brand products utilized in this installation. TERMS, CONDITIONS, LIMITATIONS 1. Owner shall provide Carlisle with written notice via letter, fax or email within thirty (30) days of the discovery of any leak in the Carlisle Total Roofing System. Owner should send written notice of a leak to Carlisle's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Carlisle, the Owner authorizes Carlisle or its designee to investigate the cause of the leak. Should the investigation reveal the cause of the leak to be outside the scope of this Warranty, investigation and repair costs for this service shall be paid by the Owner. 2. If, upon inspection, Carlisle determines that the leak is caused by a defect in the Carlisle Total Roofing System's materials, or workmanship of the Carlisle Authorized Roofing Applicator in installing the same, Owner's remedies and Carlisle's liability shall be limited to Carlisle's repair of the leak. 3. This warranty shall not be applicable if, upon Carlisle's inspection, Carlisle determines that any of the following has occurred: (a) The Carlisle Total Roofing System is damaged by natural disasters, including, but not limited to, lightning, fire, insect infestations, earthquake, tomado, hail, hurricanes, and winds of (3 second) peak gust speeds of fifty-five mph or higher measured at 10 meters above ground; or (b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind-blown objects, or: (c) The Carlisle Total Roofing System is damaged by any intentional or negligent acts, accidents, misuse, abuse, vandalism, civil disobedience, or the like. (d) Deterioration or failure of building components, including, but not limited to, the roof substrate, walls, mortar, HVAC units, non -Carlisle brand metal work, etc., occurs and causes a leak, or otherwise damages the Carlisle Total Roofing System; or (e) Acids, oils, harmful chemicals and the like come in contact with the Carlisle Total Roofing System and cause a leak, or otherwise damage the Carlisle Total Roofing System. (f) The Carlisle Total Roofing System encounters leaks or is otherwise damaged by condensation resulting from any condition within the building that may generate moisture. 4. This Warranty shall be null and void if any of the following shall occur: (a) If, after installation of the Carlisle Total Roofing System by a Carlisle Authorized Roofing Applicator there are any alterations or repairs made on or through the roof or objects such as, but not limited to, structures, fixtures, solar panels, wind turbines, roof gardens or utilities are placed upon or attached to the roof without first obtaining written authorization from Carlisle; or (b) Failure by the Owner to use reasonable care in maintaining the roof, said maintenance to include, but not be limited to, those items listed on Carlisle's Care & Maintenance Information sheet which accompanies this Warranty. 5. Only Carlisle brand insulation products are covered by this warranty. Carlisle specifically disclaims liability, under any theory of law, for damages sustained by or caused by non -Carlisle brand insulation products. 6. During the term of this Warranty, Carlisle shall have free access to the roof during regular business hours. 7. Carlisle shall have no obligation under this Warranty while any bills for installation, supplies, service, and warranty charges have not been paid in full to the Carlisle Authorized Roofing Applicator, Carlisle, or material suppliers. 8. Carlisle's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 9. Carlisle shall not be responsible for the cleanliness or discoloration of the Carlisle Total Roofing System caused by environmental conditions including, but not limited to, dirt, pollutants, or biological agents. 10. Carlisle shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages relating, directly or indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in the building or in the air, land, or water serving the building. 11. This warranty shall be transferable upon a change in ownership of the building when the owner has completed certain procedures including a transfer fee and an inspection of the Roofing System by a Carlisle representative. CARLISLE DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS LIABILITY, UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY CARLISLE OR THE PRIOR EXISTING ROOFING MATERIAL OVER WHICH THE CARLISLE ROOFING SYSTEM HAS BEEN INSTALLED THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES FOR FAILURE OF THE CARLISLE TOTAL ROOFING SYSTEM OR ITS COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND THE FACE HEREOF. CARLISLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW. BY: Robert H. McNeill AUTHORIZED SIGNATURE TITLE: Vice President, Technical and Warranty Services This Warranty Expires: January 07, 2033 WA -F0001 (1/15) i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: JobAddress: �Gi%3�1x%0,5 B Permit Number:�7G�j��d? ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: A/ Inspector: `fix`��-�— DO NOT REMOVE THIS NOTICE CARLISLE GOLDEN SEAL TOTAL ROOFING SYSTEM WARRANTY SERIAL NO. 10158811 BUILDING OWNER: WILMORE 38, LLC 969 NAME OF BUILDING: WILMORE CENTER - 7615 BUILDING BUILDING ADDRESS: 7615 W. 38TH AVE., WHEAT RIDGE, CO DATE OF COMPLETION OF THE CARLISLE TOTAL ROOFING SYSTEM DATE OF ACCEPTANCE BY CARLISLE: 01/08/2018 DATE OF ISSUE: January 08, 2018 12/22/2017 (EB Warranty) CMD1232803 Carlisle Roofing Systems, Inc., (Carlisle) warrants to the Building Owner (Owner) of the above described building, that; subject to the terms, conditions, and limitations stated in this warranty, Carlisle will repair any leak in the Carlisle Golden Sealn"Total Roofing System (Carlisle Total Roofing System) installed by a Carlisle Authorized Roofing applicator for a period of 15 years commencing with the date of Carlisle's acceptance of the Carlisle Total Roofing System installation. However, in no event shall Carlisle's obligations extend beyond 15.5 years subsequent to the date of substantial completion of the Carlisle Total Roofing System. See below for exact date of warranty expiration. The Carlisle Total Roofing System is defined as the following Carlisle brand materials: Membrane, Flashings, Adhesives and Sealants, Insulation, Cover Boards, Fasteners, Fastener Plates, Fastening Bars, Metal Work, Insulation Adhesives, and any other Carlisle brand products utilized in this installation. TERMS, CONDITIONS, LIMITATIONS 1. Owner shall provide Carlisle with written notice via letter, fax or email within thirty (30) days of the discovery of any leak in the Carlisle Total Roofing System. Owner should send written notice of a leak to Carlisle's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Carlisle, the Owner authorizes Carlisle or its designee to investigate the cause of the leak. Should the investigation reveal the cause of the leak to be outside the scope of this Warranty, investigation and repair costs for this service shall be paid by the Owner. 2. If, upon inspection, Carlisle determines that the leak is caused by a defect in the Carlisle Total Roofing System's materials, or workmanship of the Carlisle Authorized Roofing Applicator in installing the same, Owner's remedies and Carlisle's liability shall be limited to Carlisle's repair of the leak. 3. This warranty shall not be applicable if, upon Carlisle's inspection, Carlisle determines that any of the following has occurred: (a) The Carlisle Total Roofing System is damaged by natural disasters, including, but not limited to, lightning, fire, insect infestations, earthquake, tomado, hail, hurricanes, and winds of (3 second) peak gust speeds of fifty-five mph or higher measured at 10 meters above ground; or (b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind-blown objects, or: (c) The Carlisle Total Roofing System is damaged by any intentional or negligent acts, accidents, misuse, abuse, vandalism, civil disobedience, or the like. (d) Deterioration or failure of building components, including, but not limited to, the roof substrate, walls, mortar, HVAC units, non -Carlisle brand metal work, etc., occurs and causes a leak, or otherwise damages the Carlisle Total Roofing System; or (e) Acids, oils, harmful chemicals and the like come in contact with the Carlisle Total Roofing System and cause a leak, or otherwise damage the Carlisle Total Roofing System. (f) The Carlisle Total Roofing System encounters leaks or is otherwise damaged by condensation resulting from any condition within the building that may generate moisture. 4. This Warranty shall be null and void if any of the following shall occur: (a) If, after installation of the Carlisle Total Roofing System by a Carlisle Authorized Roofing Applicator there are any alterations or repairs made on or through the roof or objects such as, but not limited to, structures, fixtures, solar panels, wind turbines, roof gardens or utilities are placed upon or attached to the roof without first obtaining written authorization from Carlisle; or (b) Failure by the Owner to use reasonable care in maintaining the roof, said maintenance to include, but not be limited to, those items listed on Carlisle's Care & Maintenance Information sheet which accompanies this Warranty. 5. Only Carlisle brand insulation products are covered by this warranty. Carlisle specifically disclaims liability, under any theory of law, for damages sustained by or caused by non -Carlisle brand insulation products. 6. During the term of this Warranty, Carlisle shall have free access to the roof during regular business hours. 7. Carlisle shall have no obligation under this Warranty while any bills for installation, supplies, service, and warranty charges have not been paid in full to the Carlisle Authorized Roofing Applicator, Carlisle, or material suppliers. 8. Carlisle's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 9. Carlisle shall not be responsible for the cleanliness or discoloration of the Carlisle Total Roofing System caused by environmental conditions including, but not limited to, dirt, pollutants, or biological agents. 10. Carlisle shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages relating, directly or indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in the building or in the air, land, or water serving the building. 11. This warranty shall be transferable upon a change in ownership of the building when the owner has completed certain procedures including a transfer fee and an inspection of the Roofing System by a Carlisle representative. CARLISLE DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS LIABILITY, UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY CARLISLE OR THE PRIOR EXISTING ROOFING MATERIAL OVER WHICH THE CARLISLE ROOFING SYSTEM HAS BEEN INSTALLED THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES FOR FAILURE OF THE CARLISLE TOTAL ROOFING SYSTEM OR ITS COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND THE FACE HEREOF. CARLISLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW. BY: Robert H. McNeill AUTHORIZED SIGNATURE TITLE: Vice President, Technical and Warranty Services This Warranty Expires: January 07, 2033 �70Prinr PW) ()551 Fa: 245. 1' vvv,,va car moesyntrr r om WA -F0001 (1/15) i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 6 q 4f L _ Job Address: -76/LV39 f/� 5TE (x)05 Permit Number: 7c-01 %0969 __ I , L12 N, l r�✓., , J 4l.f�] tl l �/ . / c— T ❑ No one available for inspection: Time 1c.1, -*'2 AM/PM Re -Inspection required: Yes (5 When cons have been made, call for re -inspection at 303-234-5933 Date: 3rrec ioAp" Inspector: M77( DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division �(303) 234-5933 Inspection line �(303) 235-2855 Office (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 1164- Rod Job Address: 701 i if 36+A //ye, Permit Number: 20! 70Y gib` ❑ No one available for inspection: Time 111 210 AM/PM Re -Inspection required: Yes 9 When corrections have been made, call for re -inspection at 303-234-5933 Dater �/?_',/ 1� Inspector: har"o Lavt ' DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE �� Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Vo, l- i� l cy( Job Address: 7 15- 1/ 3104-4 /1,,e, Permit Number: 20+-7610563 Iq(w /c.,Jr) f ')f1 S�6 I (fin dry/; � / L,- res r pip ❑ No one available for inspection: Time )0" 15 _# PM Re -Inspection required: (51 No When corrections have been made, call for re -inspection at 303-234-5933 Date: Vzz//6 Inspector: L-dVeff DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3n Cl A F�,- Job Address: i.✓ ��' s le lD� Permit Number: -)-{j/ ❑ No one available for inspection: Time AM/PM Re -Inspection required(Yes No When correcf'ons have been made, call for re -inspection at 303-234-5933 Date: 3711, �l Inspector: l� DO NOT REMOVE THIS NOTICE A/kfe_s: i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 9 Job Address: S mute Permit Number: 1 ❑ No one available for inspection: Time ! l AM( Re -Inspection required: Yes ,"No *When corrections have been made, call for re -inspection at 303 -234 - Date: 3' f ' `U Inspector: <-,iI o � DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 317/ 1A�G)t ' Job Address: 26/S &sEz fq e 165 Permit Number: 70(7h Fob ❑ No one available for inspection: TimeI_AeAM/FbM Re -Inspection required: Ye'No When corrections have been made, call fo'r re -inspection at 303-234-5933 Date:3 ' F, 1F Inspector: JOA/(;11/i, �, DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 30'7 C Job Address: 7 � Permit Number: ' '0/70 ❑ No one available for inspection: Time )60 AM/PM Re -Inspection required -1 Yes /No *When corrections have been made, call for re-inspeLcttion at 303-234-5933 Date: �� Inspector: OTT DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE _��9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE �y Type: Inspection T e: Yly&wit«' p Job Address: S UJ�cP -�` /0 Permit Number:�d/ a ❑ No one available for inspection: Time Re -Inspection required: Yes k' No When corrections have been made, call for re -inspection at 303-234-5933 Date: �' cV' /' Inspector: AX/6'4��f DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ll c'`l - r_�, ,,<, ) Job Address: -7 r s' w "3 S Permit Number: --,-? C 1-7 a 'R js�- U -� ez No c,4- : L L a -L—; )al cic r,,/ (! ME MM, 11A� ❑ No one available for inspection: Time _ AMM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303 -234 - Date: Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge y; Comm. Tenant Finish PERMIT - 201709682 PERMIT NO: 201709682 ISSUED: 02/15/2018 JOB ADDRESS: 7615 W 38th AVE SUITE B105 EXPIRES: 02/15/2019 JOB DESCRIPTION: Commercial T/I 2770sgft. Proposed use -Medical Imaging Clinic equipment includes mammography and PET CT equipment. *** CONTACTS *** OWNER (303)905-9700 WILMORE 38, LLC GC (303)772-5051 Jeff Nading 160247 Golden Triangle Construction SUB (303)761-1211 Ross Whitesec 140018 Master Blaster Plumbing SUB (303)936-7924 Brad Christianson 080241 Rych Electric Inc SUB (970)506-0012 Joe Strangle 180039 Air Experts *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 403,672.00 FEES Total Valuation 0.00 Plan Review Fee 2,010.35 Use Tax 8,477.11 Permit Fee 3,092.85 ** TOTAL ** 13,580.31 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. All roughs to be done at Framing Inspection. City of Wheat Ridge Comm. Tenant Finish PERMIT - 201709682 PERMIT NO: 201709682 ISSUED: 02/15/2018 JOB ADDRESS: 7615 W 38th AVE SUITE B105 EXPIRES: 02/15/2019 JOB DESCRIPTION: Commercial T/I 2770sgft. Proposed use -Medical Imaging Clinic equipment includes mammography and PET CT equipment. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this_�ppe>;mit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work; to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature -6f OWNER or CONTRACTOR (Circle one) Date I_ This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, anew pen -nit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of anmanner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a pe' it shall not be construed to be a permit for or an approval of, any violation of any provision of any applicable code or any ordinance r regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City O Wh6,a�t 3 �t?tvt�«#iJt�ii�1Y C�f:vE:tt3i'>�vtf.i�1T 4 Building & Inspection Services Division Iq 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits .ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit #�� /76 q f _s Plan Review Fee: A 17 U - Building Permit Application�.i± *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processe *** Mailing Address: (if different than property address) Address: City, State, Architect/Engineer E-mail: Contractor: 1- Y) D , Contractors City License #: Contractor E-mail Address: For Plan Review Questions & Comments (please print): CONTACT NAME (please print) CONTACT EMAIL(p/ease Sub Contractors; Electrical: W.R. City License # Other City Licensed Sub: City License # City License # Phone: Plumbing: W.R. City License # Other City Licensed Sub: Mechanical: W.R. City License # Complete all information on BOTH sides of this form COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIAN REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM PLIA CE AIR o REPLACEMENT ❑ OTHER (Describe) caw (For ALL projects, please provide a detailed description 'of work to be performed, including current use of areas, proposed uses, square footage, existing condition and pro sed new condition, appliance size and efficiency, type and amount of m enais to be used, etc.) � v'�--- I_ l�►� � 1 G�1✓t� 1 �� It'►GIt�S r�la�, � � �r ��� Sq. FtJLF Btu's Gallons Amps Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the a a r , CIRCLE ONE: (OWNER) (CONTRAC�7°� d (JUt'HVIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): I LIU DATE: C� DEPARTMENT USE ONLY ZONING COMMMENTS' OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ Network Solutions Page 1 of 1 RE: Touchstone Imaging Tenant improvement ie A Plan Review 1123 AM Q To Jeff Jones ► % 2 attachments View Download Save to Drive Your plans and application for review have been received and accepted, and are in the queue. You will be contacted by a plans examiner once the plans have been reviewed. Our turnaround time is approximately 2 weeks. Regards, West Metro Fire Rescue Life Safety Plan Review Desk S) West Meta Fire fescue From: Jeff Jones [ mai Ito: ieff(abdavisionesarch.com(mailto:ieff(Odavisionesarch.com)] Sent: Monday, December 18, 2017 11:16 AM To: Plan Review Subject: Touchstone Imaging Tenant improvement Submittal for review. Call with any questions YJctTJorxc-. ATA Z14M V Wow" Ord, Aui��' c MVXI s .A,rchitecture Davis / jone-' 303.886,3860 **** WARNING: This email originated outside of Westmetrofire.org. DO NOT CLICK links or attachments unless you recognize the sender and know the content is safe. **** https://webmail3.networksolutionsemail.com/appsuite/ 12/18/2017 U COMcheck Software Version 4.0.7.0 Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: 2012 IECC Touchstone Imaging Wheat Ridge, Colorado 5b Alteration "• �Fc s 36005 m `` ca t 2-11,-1 f� S/�nie�E� Construction Site: Owner/Agent: Designer/Contractor: 7615 W. 38th Ave. Christopher Menges Suite 8105 Christopher Menges Engineering, Wheat Ridge, CO 80033 Inc. 1100 W. Littleton Blvd Suite 400 Littleton, CO 80120 Mechanical Systems List Quantity System Type & Description 1 RTU -1 (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 115 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency = 80.00% Et Cooling: 1 each - Single Package DX Unit, Capacity = 36 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 14.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 HVAC System 2 (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 115 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency = 80.00% Et Cooling: 1 each - Single Package DX Unit, Capacity = 48 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 14.00 SEER, Required Efficiency: 13.00 SEER Fan System: None 1 Water Heater 1: Electric Storage Water Heater, Capacity: 40 gallons w/ Circulation Pump Proposed Efficiency: 0.90 EF, Required Efficiency: 0.88 EF Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.7.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. CWCt05TV?f4Ck NjgN[r&5 - PRES o/)F__—r i 2 -IPS - t 7 Name - Title Signature Date Project Title: Touchstone imaging Report date: 12/18/17 Data filename: Z:\Projects\2017\171202 -Davis Jones -Touchstone Mammo\Touchstone.cck Page 1 of 9 5 - i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Q 01 7�i" Job Address: -7 f� I k-0 G),) 5_ Permit Number: 2 Z) l 4- Q 9 ❑ No one available for inspection: Time Re -Inspection required: Yes oNo When corrections have been made, call for re -inspection at 303-234-5933 Date: � 4-J Inspector: i DO NOT REMOVE THIS NOTICE `` 'Vt v,Ew �� ��in _�/- �r 4'ea's PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Commercial Remodel PERMIT - 201707214 201707214 ISSUED: 10/02/2017 7615 W 38th AVE SUITE A104 Commercial demo and tenant finish; Demo XofRexisting nonstructuralwalls in existing space excluding existing to remain bathroom; Build one wall to divide off j�b.ack arm from front w/pass thru opening. *** CONTACTS *** n OWNER (720)528-3346 DPC COMPANIES SUB (303)778-8555 Alan Waring & Michael Palmer 060220 SUB (303)778-8555 Alan Waring & Michael Palmer A&B Builders, 060220 Inc. A&B Builders, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail USE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,2.43.00 Total Valuation FEES Plan Review Fee 0.00 Use Tax 70.98 Permit Fee 68.10109.20 ** TOTAL ** 248.28 *** COMMENTS *** *** CONDITIONS *** Approval from presiding fire department required prior to final building inspection sign -off. All roughs to be done at Framing Inspection. City of Wheat Ridge Commercial Remodel PERMIT - 201707214 PERMIT NO: 201707214 ISSUED: 10/02/2017 JOB ADDRESS: 7615 W 38th AVE SUITE A104 EXPIRES: 10/02/2018 JOB DESCRIPTION: Commercial demo and tenant finish; Demo of existing non structural walls in existing space excluding existing to remain bathroom; Build one wall to divide off back area from front w/pass thru opening. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. , to Signature of OWNER or ON*ACTOR.jCircle one) Date 1. This permit was issued base _-information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, of'lWapproval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPE ON THE FOLLOWING BUSINESS DAY. N°�&1 City of �WheatP,die COMMUNITY DL--VELOPMENT Building & Inspection Services Division 7500 W. 29`h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits ci.wheatridge.co.us FOR OFFICE USE ONLY Date: /i a Plan/Permit #� Plan Review Fee: g Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: qia 15 W • 3 /-t VG- . , 5q ITi✓ Property Owner (please print): T>('C Cot<1 f 1 tN 116,S Phone: 420 - S2[3 - 33`i V Property Owner Email: 'J,r-e.@ 4C CornpctnieS. c4M Mailing Address: (if different than property address) Address: j poo S - Ji4lC) 1 6JE , .. 50o City, State, Zip: A6,4gQ_ Cc Arch itect/Engineer: W AVJM(a A5,S0UP1ES Architect/Engineer E-mail: _gmarldA@wgr;ttc, bFC-;c..e• wn1 Phone: 303- 7-q2 —3 2 d Contractor: / -5q I LtmE:PS Contractors City License #: loo 22o Phone: 3o3 6555 Contractor E-mail Address: r iCqs-�(IV C 4cAnj 6�U I Wey's •YQ+ Sub Contractors: Electrical: -iiQ ) l.-vt- —s W.R. City License # 1oa220 Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ^ N%4 9 e� OTHER (Describe)rCMP%grJAI—-aftVT 10 9e -N -E 14� Oi1wr4zt/rcmctr ?) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, A5 - proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) VG�1D Oq C -,X1- fnPGi r4oN -.s1`2 V,14& WrUs t14 e�?4 IS-nHC1 s?0t-1:7i �XCWDJqc1 Isfil.ir� 1-0 9-45Ht >4 1�ftrW-ZM . 1 >UlLD ort AMI, L- TO Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ 32Dd OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, Hiles or regulations of the City of Wheat Ridge or covenants, casements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) ((CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Signature (first and last name): ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer:/�Iq •tiQ•h DEPARTMENT USE ONLY DATE: OCCUPANCY CLASSIFICATION: IV -4 AA41FO� SMA S L, -A,. Nin 7D \16CW4 Building Division Valuation: $ BUILDERS General Contractors 2810 W. 8th Avenue Denver, CO 80204 Mary S. Hess Phone: (303) 778-8555 Fax (303) 778-8570 Project: Epic Smoke Shop Client: DPC Contact: Jess DiRe Designer: Waring Plan Date: 9/5/2017 Est. Date: 9/27/2017 Rev Date: n/a Project Address: Log IT: EH17 174 Wilmore Center Project Sf: 1230 7615 W. 38th Ave., A-104 Cost/ Sf: $2.64 Wheat Ridge, CO Cost Itemized Unit Subtotal Category Code Categories Qty Unit Cost Cost Subtotal 1000 General Conditions Project management 1 Is 165.00 165.00 Subtotal: $ 165.00 2000 Site Work & Demolition Remove drs/frms and/or window/frms 1 ea 25.00 25.00 Demo floor coverings 137 sy 2.00 274.00 Demo partitions 53 If 10.00 530.00 Trash haul 1 ea 250.00 250.00 Broom clean bare space 1230 sf 0.12 148.00 Subtotal: $ 1,227.00 9250 Drywall Partition to under grid 20 If 39.00 780.00 Wrapped openings 1 ea 125.00 125.00 Subtotal: $ 905.00 9900 Paint & Wall Coverings Paint interior walls, 1 coat 1692 sf 0.32 541.00 Subtotal: $ 541.00 16000 Electrical Demo and cap -off 2 hrs 55.00 110.00 Subtotal: $ 110.00 Numbers Check $ 2,948.00 SUBTOTAL: $ 2,948.00 Probable Permit & Plan Check Fee, Use Tax (Unkown, Excluded): $ - Contingency 0.0% $ - O&P: 10.0% $ 295.00 TOTAL: $ 3,243.00 Budget Clarifications: 1. This budget is for pre -construction use only and may not represent actual scope of work required. 2. Budget is based on work to be performed during normal business hours, unless otherwise noted. 3. All proposed work would be guaranteed to be done according to industry standards. Any alteration or deviation from proposed specified work, involving extra costs would be executed only upon a signed written change order. 4. Budget pricing excludes the following items: A. Architectural or engineering design fees or drawings unless otherwise noted above in budget. B. Hidden or concealed conditions including, but not limited to, plenum violations, rated wall violations above existing ceilings, slab or deck damage covered by flooring. C. The removal and treatment of hazardous materials. D. Existing code violations unless otherwise noted in above budget. E. Major floor prep. F. Tenant computer & phone wiring equipment & terminations. G. Moving & relocation of tenants furniture & file systems. H. Any modifications to base building fire alarm and fire alarm panel systems. I. Supporting or wiring of existing light fixtures. J. Locksmith of any doors. K. All architectural General Notes unless specifically itemized in above proposal. L. All Xcel Energy, or other Utility Company's, fees or charges. 5. Budget priced from plans dated: Revised: Budget Submitted By: Date: Ellary S. Hess, Estimator A&B Builders Acceptance Of Budget: The above prices have been accepted as budgetary conditions. A&B Builders is hereby authorized to commence the work required to create a binding Proposal between all parties. Signed: Date: I Occupant Name: Epic Smoke Shop Address: 7615 West 38th Avenue Wheat Ridge, CO 80033 Suite: A104 Occupant Sq. 0 Footage: Contractor: A&B Builders Robin Easterly West Metro Fire Protection District 433 S. Allison Pkwy, Lakewood, CO 80226 (303) 989-4307 Job Number: 170908004 Job Description: Demo of existing non-structural wall in existing space, excluding existing to remain bathroom. Build one wall to divide off back area from front with pass through opening. Inspection Date: 9/8/2017 Your plans have been approved. Using information provided below in the "Comments" section, complete this payment form in its entirety. Once the invoice has been paid and you receive an email confirmation of payment, email a copy of the receipt to planreview cr,westmetrofire.org. Once our office receives the email payment confirmation, we will email the permit, plans, and cut sheets (if applicable) in the form of a Drop Box link. You are required to print a hard copy of the permit on 8 %" X 14" paper, as well as the approved stamped plans in the recognized architectural drawing size ARCH D or ARCH E and cut sheets (if applicable) and have them accessible on-site for inspections. This information must be on-site for inspectors when they arrive for inspections. West Metro Fire Rescue Life Safety Plan Review Desk Inspection 9/8/2017 Comments: • Access the E -Payment page by clicking on the "form" link located above. • Select "Life Safety" under the Bill Type drop down menu. • Enter invoice number # 17090814506 • Select the associated permit type from the "Permit/Fee Type" drop down menu. • Select "Construction Permit" in the WMFR Acct# drop down menu. • Enter the "Job Address" • Enter a payment amount of $241.00 • Select "Pay by Card" to complete the transaction. Current Status: Approved A9A Boulder Environmental Inc. 2400 Broadway St., Unit B, Boulder, CO 80304 Phone: (303) 382-1175 Fax: 1 (866) 699-4121 September 12, 2017 A&B Builders Mr. Ellary S Hess 2810 W 8t" Ave Denver, CO 80204 shess(c,,,aandbbui lders.com RE: Bulk sampling of suspected asbestos -containing materials 7615 West 38" Avenue, #A104, Denver, Colorado Dear Mr. Hess: Attached is the report for the asbestos survey and bulk sampling of suspected asbestos - containing building materials at 7615 West 38" Avenue, #A104, Denver, Colorado. This investigation was conducted on behalf of and for the exclusive use of A & B Builders (client), solely for use in a limited asbestos survey of the property. This report and the findings herein shall not, in whole or in part, be disseminated or conveyed to any other party, nor used by any other party, in whole or in part, without prior written consent of Boulder Environmental Inc.. The results of this survey are limited to materials that were assessable and foreseeable. Additional materials may exist behind hard surfaces. Personnel knowledgeable of asbestos containing materials should always oversee demolition activities. Demolition work should be halted and sampling performed by a state of Colorado licensed building inspector if additional materials, which are suspected of containing asbestos, are encountered. If you have any questions regarding the contents of this report, please do not hesitate to contact us. Sincerely, Chris Maron Project Manager *Asbestos*Lead*Industrial Hygiene*Safety*Final Air Testing* *Health and Safety Training* i Boulder Environmental Inc. 2400 Broadway St., Unit B, Boulder, CO 80304 Phone: (303) 382-1175 Fax: 1 (866) 699-4121 BULK SAMPLING REPORT 7615 West 38th Avenue, #A104, Denver, Colorado Introduction: On September 11, 2017, Boulder Environmental Inc.'s Building Inspector, Catherine Naccarato, conducted bulk samplingof f suspected asbestos -containing materials under the direction of our client. Sampling: During the sampling process, suspect ACM was separated into three EPA categories. These categories are thermal system insulation (TSI), surfacing ACM, and miscellaneous ACM. TSI includes all materials used to prevent heat loss or gain or water condensation on mechanical systems. Examples of TSI are pipe coverings, boiler insulation, duct wrap, and mud packed fitting cement. Surfacing ACM includes all ACM that is sprayed, trowelled, or otherwise applied to a surface. These applications are most commonly used in fireproofing, decorative and acoustical applications. Miscellaneous materials include all ACM not listed in the thermal system insulation or surfacing categories, such as linoleum, vinyl asbestos flooring, and ceiling tile. Boulder Environmental Inc. followed EPA recommended sampling guidelines for identification of asbestos in bulk matrices. A set of three (3), five (5), or seven (7) samples were collected for each material type and analyzed by Polarized Light Microscopy (PLM). Each sample set was systematically analyzed. Upon determination that a sample in a set contained asbestos, analysis of the remaining samples in the set was discontinued. If no asbestos was detected during the analyses, the suspect material was determined to be negative for asbestos content. *Asbestos*Lead*Industrial Hygiene* Safety *Final Air Testing* *Health and Safety Training* Boulder Environmental Inc. 2400 Broadway St., Unit B, Boulder, CO 80304 Phone: (303) 382-1175 Fax: 1 (866) 699-4121 Results: The following materials were analyzed and determined to be non asbestos -containing utilizing polarized light microscopy (PLM). NON ASBESTOS -CONTAINING MATERIALS MATERIAL SAMPLE LOCATION SAMPLE ID Stomp textured % wall front area north side 9 -11 -CN -01 A drywall V2 wall rear of front area west side 9 -11 -CN -02A Back room upper east wall 9 -11 -CN -03A Stipple textured West center wall -front area 9 -11 -CN -0413 drywall Hall interior south wall 9 -11 -CN -05B West full front area wall -north side 9 -11 -CN -06B Joint compound Hall southeast corner 9 -11 -CN -07 on drywall system Floor tile 12x12 Floor (throughout) 9 -11 -CN -08 Ceiling tile 2'x 4' Ceiling (throughout) 9 -11 -CN -09 Discussion: Sample analyses results are reported in percentages of asbestos and non -asbestos components. The EPA defines any material that contains greater than one percent (1%) asbestos, utilizing PLM, as being an asbestos containing material. Materials that are identified as "none detected" are specified as not containing asbestos. If asbestos removal is required: (Asbestos removal permits and notifications): Asbestos removal in Single Family Residential Dwelling (SFRD's) in quantities of "> 50 LF or 32 SF or a 55 -gallon drum, but _5 260 LF or 160 SF or a 55 -gallon drum" requires a permit or notification requirement for asbestos removal contractors which involves a ten working day waiting period. Removal of non -friable asbestos containing building materials requires a notification fee of $60. Removal of friable asbestos within this range of quantities requires a permit fee of $180 for a friable asbestos removal. If the quantity of ACBM to be removed exceeds is "> 260 LF or 160 SF or a 55 -gallon drum" in a Public and Commercial Building, School or a SFRD, a permit/notification a ten working day waiting period is required before a permit is valid. These circumstances also require a notification fee of $80 for a non -friable asbestos removal or a permit fee of *Asbestos*Lead*Industrial Hygiene*Safety*Final Air Testing* *Health and Safety Training* Boulder Environmental Inc. 2400 Broadway St., Unit B, Boulder, CO 80304 Phone: (303) 382-1175 Fax: 1 (866) 699-4121 400 for a friable asbestos removal. These trigger levels apply to SFRD's which are intended to be demolished. Emergency asbestos abatement / demolition permits may be issued if project circumstances pose an immediate hazard to public health and environment. CDPHE does not typically waive permit waiting periods because of financial hardships or planning issues. Requests for emergency asbestos abatement / demolition permits must be made in writing by the building owner to: Permit Coordinator, Colorado Dept. of Public Health and Environment, APCD-SS-B1, 4300 Cherry Creek Drive South, Denver, CO 80246- 1530, Phone: 303-692-3100, Fax: 303-782-0278, Email: cdphe.asbestos&state.co.us. Opting out: Since the scope of previous public health regulations did not include single-family residential dwellings, the Colorado Department of Public Health and Environment was unable to protect homeowners from these exposures. With this new law homeowners who reside in the home they wish to renovate can now choose to be afforded the same protections as they are entitled to in a public and commercial building, unless the homeowner chooses to waive this protection. To waive these protections, the homeowner must sign this form declaring that they do not want their home to be considered an "Area of Public Access" for purposes of determining the applicability of portions of Colorado's asbestos regulation. The term "Area of Public Access" is unique to Colorado's asbestos regulation and basically determines if an abatement permit, engineering controls, and air clearance testing is required. If a building is not an "Area of Public Access" then only certification, notification and asbestos disposal requirements in Colorado's regulation are applicable. This declaration will not affect you in any other way as it only determines your home's status with respect to Colorado's asbestos abatement regulation. CDPHE may decide, on a case-by-case basis, to waive the 10 working -day waiting period for an Opt -out form. Where the homeowner has chosen to opt -out, the residential dwelling will revert to being an area of public access subject to all the protective requirements contained in Colorado Air Quality Control Commission's Regulation No. 8, Part B: 1) at the time of the homeowner's choosing; 2) when the homeowner no longer own the single-family residential dwelling; or, 3) if the dwelling ceases being the homeowner's primary residence, whichever is first. *Asbestos*Lead*Industrial Hygiene* Safety* Final Air Testing* *Health and Safety Training* 3 Boulder Environmental Inc. 2400 Broadway St., Unit B, Boulder, CO 80304 Phone: (303) 382-1175 Fax: 1 (866) 699-4121 State Demolition Notification: A state issued demolition permit is required prior to the demolition of load bearing members. Please contact Boulder Environmental if the scope of demolition changes to include building materials that were not accessed at the time of this study. Projects involving the demolition of load bearing members may be denied the liberties conveyed by an "opt -out form". Please note that walk-in business address for CDPHE is different from the mailing address on CDPHE forms. Their physical address is 700 South Ash Street, Denver, Colorado. Please contact Boulder Environmental if the scope of demolition changes to include building materials that were not accessed at the time of this study. Conclusion: The following materials were determined not to be asbestos -containing: • —250 square feet of stomp textured drywall, including joint compound in cracks and joints, on both sides of all the %2 walls, back room east walls and front south side west wall • —400 square feet of stipple textured drywall, including joint compound in cracks and joints, on the hall interior walls and bathroom surround walls • —1400 square of 12x12 floor tile and mastic throughout the unit • —1400 square feet of 2'x4' white ceiling tile throughout the unit The results of this survey pertain only to materials tested. The laboratory reports supporting these findings above are attached. A state issued demolition permit is required prior to the demolition of load bearing members. If your project involves the demolition of load bearing members, please contact Boulder Environmental Inc. and we will mail you the signed demolition notification form that you must submit to attain a state of Colorado demolition permit. *Asbestos*Lead*Industrial Hygiene* Safety *Final Air Testing* *Health and Safety Training* t Boulder Environmental Inc. 2400 Broadway St., Unit B, Boulder, CO 80304 Phone: (303) 382-1175 Fax: 1 (866) 699-4121 Please contact Boulder Environmental Inc. if you have any questions or concerns regarding this report. Sincerely, Chris Maron Project Manager *Asbestos*Lead*Industrial Hygiene*Safety*Final Air Testing* *Health and Safety Training* Reservoirs Environmental, Inc. Effective January 1, 2015 Reservoirs Environmental QA Manual T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc R7r,.B Reservoirs En vironmen ta/, Inc. September 11, 2017 Boulder Environmental, Inc. 2400 Broadway, Unit B Boulder CO 80304 Dear Customer, Subcontract Number: Laboratory Report: Project # I P.O. # Project Description: NA RES 389473-1 None Given 7615 W 38th #A104 Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 389473-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, Jeanne Spencer President P:303-964-1986 F:303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 o11 1-866-RESI-EN V www.reilab.com U Z_ J Q H Z W 2 Z NON 1.6. Z W N w O W N w w FO W J m Q H ti C C m E C O t`7 C W 00 d MLU 0 p w m W 78 E '- N O W 'w U co CL) N N � o o E N p v � c u u C U U O (` Q Z E p a) z�� Y 7 m 0 0. 0 O L n � o c (n � N � � � M t r p) 42) co > 0 M C 6 3-.E a L G1�d. O t0 O o S Z n W W N O C:)000000000000 d c . o fU > N .O_ N U T (6 LO O O Q .o Z 0 E O U U N (U Z O O O O (O Q E CQC C o a a fn o° fn w C C C O L fn C (U N O N LU O LL 01 w U U U 0 H 0 C C✓ C:)000000000000 O O C o LO O O O LO O LO O f0 O (O O (O Z O LL 01 E O U C toV7 >o O O O 00 00 0 0 O O O O Z u�O N LO to LO LO LO Lo O C ii a O U R;; 0 000 Cana 00 00 00 R. = Z Z Z Z Z Z Z Z Z Z Z Z Z N E O W V........... N O N Wf L N m Q c Z3f �LO0 OO U-) U') LO U') U') U') 0 L � - N O LO Lf) CO O ch (D N r N f` C UO — Q T U d N °� ani ani _ ani 3 m 3 (° cu o Z 3 -o 3 .o -0 3 -O O a) a d 'O o o o 3 c o o c 3 (6 U N -a 2O f6 .o L N O` L L O' L L L 7` Um> n >L >CD m U J Q} W Q m U Q m Q m Q m Q m Q m LD (D f` 00 O O co co OO O O E co rn rn rn co co 0 J W W W W W W Q N M m m co (D O O O O O O Z Z Z Z Z Z w CL L U U U U U U m E E U fn Z 0) m 0) m 0) m 0 Z o w U U) N w c k U _z J Q H z W E z O I.L z W Cl) NN �.I� O W W W w 4 w m Go 0 m 0 O U CLR J Q J z V C Y 7 m C O.4 o 0 00 � Lo O OU') O O w O O O O O N Z 2 C 11 O C1 E O U O O C\ 0) 0 0 O O 00 z cn O a> " a� c O LL Cl O U -roof..- DODO D O 0 z z z z z z z O W V........... N O N d a 7 (6 o N Cl) V Lr) Lo O U) 0 C UO — C2 rn L >+ U a) C1 a) C_ a C a) U O N 3 OCL U E 25, N U C U C2 QC O O U T .0 �6 O E m a) N o L L L L = C L J Q} LL W Q m U 0 Q m Q L Y) N 0) Cl) CA O O O E E (h @ M O) M CA J W W LU O 00 O O m y Z Z z = Qs C) U U d E E V " Z 0) [% 0 V N (6 D N J .Q O C(0 C C O U C N O) O O w a (D C a) E E O U N U O _T C6 c CQ G LU H Z o W U w m W � 333 coo 3 m 3 d W H $ I W d .PI M d101 8 "OH m (S)SMW • S1V13W - c e;q-!dsa?� 'leiol isno € i VHSO 'EOOOt 'VOOVL • WOd o R m edeJd IowlpuhOSl 'aan•wo!iN iuenweS luenp lisnp to jI^S'+!71 9+ 'OSI 'ZOVL '11 Wal enpepleno 'Vodej 6uol •WOO i iOd�� Vo4S - Wld - d 5 �6 C p j 7 ok Q _s E' R°" H3c -� ¢ c d 3 E Gn p c 3 4 R i u 3 >oo c E c 1 a pLn ad ow E m£ p T CL m uni c A m R p o i �' �� d ;; w c M u _} W m _I m u r E c ' C9 T R t i n F 0 L N Y O 7+ d N O N A'r It cY II R cam` p tfJ N = O c > R. N m j E VO i oay.' 3 CD to Q g a EJ O N mcL p J t` w nr 0 Q c E3 N al W 'G O C O g c O `O h (9 m i H w E ~ ° ~ 11 cn y c y N ut n Ci iz c� a c a r; w z d V a) m m i�\1 W =' E c5 C0J o r u .� t !- .`u y E i b O D VOi 4 4 Z a l U i W Z O F- w a U N n .f n co h ao rn w O 0 m 3 E5 2 e• Wt � \ a RR U C Ietusun OAAu3 io `tll 'uaptngo(g .LeUlO ' v p It riu 3 ~� a yTi+ = LL J uognygueno 10 '/4•le6unjep8)M3 Q _ F X } ti m W 0 1 Q Q p m SJOUISJU03 i1 QI > rl n m = o {m7 3: 8 %i B OOPl W > Q p _ � W ea y r (l) own; oA aldweS r D O` xa - to r Jeuegolgdure shame sub s otoeq ii :S310N 113H10 ti0 $1VIlINi 5.831dWtlS _ ..... _ aigelA•uoN w OIQV!A ucuesgnuen0 C! H $ I W d .PI M d101 8 "OH m (S)SMW • S1V13W - c e;q-!dsa?� 'leiol isno € i VHSO 'EOOOt 'VOOVL • WOd o R m edeJd IowlpuhOSl 'aan•wo!iN iuenweS luenp lisnp to jI^S'+!71 9+ 'OSI 'ZOVL '11 Wal enpepleno 'Vodej 6uol •WOO i iOd�� Vo4S - Wld - d 5 �6 C p j 7 ok Q _s E' R°" H3c -� ¢ c d 3 E Gn p c 3 4 R i u 3 >oo c E c 1 a pLn ad ow E m£ p T CL m uni c A m R p o i �' �� d ;; w c M u _} W m _I m u r E c ' C9 T R t i n F 0 L N Y O 7+ d N O N A'r It cY II R cam` p tfJ N = O c > R. N m j E VO i oay.' 3 CD to Q g a EJ O N mcL p J t` w nr 0 Q c E3 N al W 'G O C O g c O `O h (9 m i H w E ~ ° ~ 11 cn y c y N ut n Ci iz c� a c a r; w z d V a) m m i�\1 W =' E c5 C0J o r u .� t !- .`u y E i b O D VOi 4 4 Z a l U i W Z O F- w a U N n .f n co h ao rn uoyeminuoP! -14 7MIng io deil ajodS..ploVi \ Ietusun OAAu3 io `tll 'uaptngo(g .LeUlO ' v C u0jlv3gquen0 jo -1. ellauo!6al 0 f 4 yTi+ = N J uognygueno 10 '/4•le6unjep8)M3 Q _ F E 0l Jo W q A 'Di luno oleld OM=V :%amojD lelgo.lalW d W >- 1 Z ON / seA (9u0 e1DJ!0 eseeld) J0ie111 eWIS > L q 31 1+ .suuo I to ua I Oa• uo eol •;uen o V o0 t 3 > O _ � W IF uOl vo I uen : D xa - to r Jeuegolgdure shame sub s otoeq ii Ch W e a 3 I S...lu ateld otgwaV •sueBo to '... 4 d o C! SSl HAV4-S01[WflkO .. .-_,. +� LL Kd .ueP... eta own eawn 6u, a H $ I W d .PI M d101 8 "OH m (S)SMW • S1V13W - c e;q-!dsa?� 'leiol isno € i VHSO 'EOOOt 'VOOVL • WOd o R m edeJd IowlpuhOSl 'aan•wo!iN iuenweS luenp lisnp to jI^S'+!71 9+ 'OSI 'ZOVL '11 Wal enpepleno 'Vodej 6uol •WOO i iOd�� Vo4S - Wld - d 5 �6 C p j 7 ok Q _s E' R°" H3c -� ¢ c d 3 E Gn p c 3 4 R i u 3 >oo c E c 1 a pLn ad ow E m£ p T CL m uni c A m R p o i �' �� d ;; w c M u _} W m _I m u r E c ' C9 T R t i n F 0 L N Y O 7+ d N O N A'r It cY II R cam` p tfJ N = O c > R. N m j E VO i oay.' 3 CD to Q g a EJ O N mcL p J t` w nr 0 Q c E3 N al W 'G O C O g c O `O h (9 m i H w E ~ ° ~ 11 cn y c y N ut n Ci iz c� a c a r; w z d V a) m m i�\1 W =' E c5 C0J o r u .� t !- .`u y E i b O D VOi 4 4 Z a l U i W Z O F- w a U N n .f n co h ao rn :A8 GSIA13MU STI(MVS (J_JJ')T110,D S31dINIVS N1 Wvnv Vt LUO `d 1.1LlIO n &JlZel gul, 5i'l !ze .111IU2) sititleoo adid oillutidsV ELIU00.1 Palutisa.1c Lit Ile SB/.IUI ❑snuouo3adid 11 Ile 11AI!z61.0 juildsV oil oLIUOO,l j�Kruu'aajduq i1nildsupul atlsettl LVAE] IVADI! 1100 S oisaclse 1,(MA 39YUV3 patlaula(l JDA N10JIV, :)Iqddv Otuap J[Oj 311SUM IVA n iVA al!1 JOOU SOISaqStl JXUIAE] 1 NOI.LVDI'IddV OUIOP -Hod aA01's []'p.inoqasLq =oil2l n '11U p0o.10_4 'Llfu,4iS [] :ad,A.L tt")uati pall:) F-1 S.j()OLI cin il!nq :JOO'd :Qdico tiopuinsu1 oplV njUaMaSUSElEl az)uds JA :GaSSM o0uW11�] luzu'a) 'ulLto;;)Je ❑ nj �Jom-ljncl n,.N.Datp alqno(] (311sojop I iumpu,j) sod'd 4 c, rO r Iro 1. c''vi--4 vog-1 W-41 -�f v wn 0, yea ruiju\vfio NOLLVDIDTONA111119 ..,..(IljrldNVsrlvlu:lljLvl" (11 31jWvs J'5000';�3! SaIdLUICS L "YSOOO,S_TSOOO' I Slulialrul nloq.111S .10j Sal OttleS S'Saldules C U111UNWIN - Pa,aOtJOJ 103010-1d V-13HV;s :U0111allp s,ivatp j3daldtuvS � I!ttijld v pau ll!m dol dod R uopwojsaj/uop12Ao11Z-�j PaPupc] <s/patls F1 a2r"" R Jvjj1Tap!Sa2[ r-1 tioilllotiiap'atiipl!nqzlaiduioD[]:2do:)S :vHa NOUXIMISNOD d�Z 13, 1"ALT V 11� mopu.1ploo OIU,3(l :03KP0N1r111ffANYd1,AJOD 10XjtjU3U1LJOJ1Atap1nog§sutlD :He1tG 'I Z I�-669 (999) 1 APA '9L I 1-7� ccos ap'.11pillog e iltin sumpuwq octz aF .. Co 1 1876 t Colorado Department n of Public Health and Environment ASBESTOS CERTIFICATION* This certifies that Cathy Naccarato r { _� •r Certification No.: 17528 has met the requirements of 25-7-507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part B, and is hereby certified by the r; state of Colorado in the following discipline: Building Inspector* _ _ �►''' �t : Issued: February 15, 2017 i Expires: February 21, 2018 This cerci cute is valid only with the possession of a r; 'Y current Division -approved training course certification r in the disci lines ct ed above.. P pe .ii authorized A, C[7 Representative �; SEAQ . ,, rna rs. rn�s.,rn ., , . , °.�•a•tr .. „ .. _ ,. _ . ., ,. , . ,. , ,s ., h . s1 A u.. D .. ,, u_._u,: r. Ya -_f iCrYl, ... ....d.�G.:C< ZS1j', Ave- k�,J (30 1 1 7 OCZ) Occupancy_T)r� INSPECTION RECORD (c� INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:54 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Inspector comments --oundation Inspections ®ate Initials ,ler ;oncrete Encased Ground (CEG) =cundation / P.E. Letter --- Do Not Pour Concrete Prior To Approval Of The Above inspes Inspector Comments Underground/slab Inspectioris i [tate initials lectrical Sewer Service Plumbing F; rim rnvpr llnderaround or � on, owtllno�—kPiorTo Approval O The Above Inspections -_ -pate Bough Inspections I Inspector• Initials Comments _--__.-- --- — _- i^fall Sheathing - -- -- --- -- ---- --- - - --- j iVlid-Roof I Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line 7 Rough Mechanical Rough Framing 19/-7/0 Insulation Drywall Screw / Nail --/ / - - - — - - --� i _. ---- -- - ---- -- __-- -- Final inspections date Inspector — Comments lnitiait. ; _ Inspections from these entities should be requested - --- —4— Landscaping & Parking ! Planning Dept. _ --1 — � one week in advance. icor landscaping and parking inspections call 303-235-28x.5. For ROW and drainage ROt Drainage /Public Works Dept. • Fire Inspection /Fire Protection Dist. � �z )� --- ;— l inspections call 303-235-2861. For fire inspections I contact the Fire Protection District for your projec�-. --- Final Electrical Final P;umbing Final Mechanical /t /7Roof l i I Final Window/Doors Final Building No E: Aii items must be completed and approved dy Planning, Public Works, Fire arra buttoong cRrore a E.Vrl11IL.aLU of Occupancy is issued. Approval of the Final Building inspection dors not constitute authorization of occupancy. *For load voltage permits - Piease be sure that rough inspections are completed from the Fire District and electrical icut voltage by the Building Division. **For Inspection Time Window Requests - P9e�se er�ai! insntimereciuestftci wheatridoe.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy is Not Permitted Until A Certificate of Occupancy is issued Protect This Card From The Weather Demolition General Notes 1. Demolition is to include all walls, doors and frames, ceilings, floor finishes, plumk�ing fixtures and mechanical ceiling fixtures within the perimeter demising walls. 2. The Genesi Contractor shall. include a subgrade floor coatingJlevelerlpatch for the entire floor suface A. Ardex V1200 or similar Column wrap to remain Demo plywood floor filler i • Verify extent in the field Demo furring around exi; • Install new walls as sh • Excavate o u • Com pact soi l • Install 1 i2" thick polyet#� * I�stalt rein PET �C ,�,., nt. • Install new full heig�''� style .and finish. .---� • Install privacy filr f Demo furring around exi • Install new walls as sh Der�no Pian 1 1 f, .... 3116 — 1 -C� Nt�R1 Demo Slab Section 3116' = 1'-0" 0 0 N f N 0 N architecture 2107b E. Jefferson Circle, Aurora, CO 80013 Davis /Jones 303.886.3860 �� ��� �� / �� ��,, �4 +� ' JEFFREY A. U o JONES o r- C-4859 � � (� � �� �� S F �`� D ,� t�. 12-18-17 Building Site: Touchstone Imaging -Wheat Ridge 7615 W. 38th Ave.,Suite B105 Wheat Ridge, CO 80033 Tennant: Touchstone Imaging General Contractor: Architect: Jeff Jones, AIA DavislJones Architecture, Inc. 21 fl76 E. Jefferson Circle Aurora, CO 80013 303.886.3860 Mechanical Engineer: Jeff Gellman Christopher Menges Engineering, Inc. 11 flfl W Littleton Blvd #40fl Littleton, CCS 72fl,283.3018 Etectricai Engineer: Bryan Kazin, PE Karin &Associates, Inc. 8364 Teddy Lane, Suite 101 Lone Tree, C4 80124 720.489.1609 Structural Engineer: Craig Carroll Monroe &Newell Engineers, Inc 140fl Glenarm Pl, #141 Deaver, Cts 802fl2 Mo. Description Date Touchstone Imaging Imaging Clinic Demo Plan Project number 17-029 Date 12-15-17 Drawn by JAJ checked ny Checker D 1.0 �� „�_ ._ _ . � ��: y - � �� �; �� � .. t � �: * A , City of Wheat Ridge Commercial Demolitio PERMIT - 201800125 PERMIT NO: 201800125 ISSUED: 01/11/2018 JOB ADDRESS: 7615 W 38th AVE EXPIRES: 01/11/2019 JOB DESCRIPTION: Commercial interior demolition - Suites B105, B107, Bill - demo interior walls, remove and cap plumbing, HVAC, make safe electrical - 2,600 sq ft *** CONTACTS *** OWNER (303)796-8288 WILMORE 38 LLC GC (303)341-7242 Charles W. Cullens 180003 Emerald C.M., Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 16,000.00 FEES Total Valuation 0.00 Demolition Fee 50.00 ** TOTAL ** 50.00 *** COMMENTS *** *** CONDITIONS *** Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepennit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This, permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing, and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpennit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code ordinance or rlatio oft isjurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. JOB CODE PERMIT:90�(000,SADDRESS-N `; /�. 3O� Rough Inspection (continued) Date Inspector CommentsInitials 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous I l lka I dT e Final Inspections Date Inspector CommentsInitials 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. '`For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Req ue t an inspection before MIDNIGHT (11:59 PM) to receive an 'nsp ction the following business day PERMIT�C� ADDRESS: e � JOB CODE: r AM i n Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS V i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 a Job Address: 7 (-I 4=� Permit Number: D ) -6 O 0 I of f 3v C 4- ❑ No one available for inspection: Time q: 3 7A), PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: 1 ` c Inspect` r: ' _ 1 DO NOT REMOVE THIS NOTICE t. j ti City of Wheat Ridge Commercial Demolitio PERMIT - 201800125 PERMIT NO: 201800125 ISSUED: 01/11/2018 JOB ADDRESS: 7615 W 38th AVE EXPIRES: 01/11/2019 JOB DESCRIPTION: Commercial interior demolition - Suites B105, B107, B111 - demo interior walls, remove and cap plumbing, HVAC, make safe electrical - 2,600 sq ft *** CONTACTS *** OWNER (303)796-8288 WILMORE 38 LLC GC (303)341-7242 Charles W. Cullens 180003 Emerald C.M., Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 16,000.00 FEES Total Valuation 0.00 Demolition Fee 50.00 ** TOTAL ** 50.00 *** COMMENTS *** *** CONDITIONS *** Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perforin the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include al I entities named within this document as parties to the work to be perforined�d th�tjall wort �pertormed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date / — / / – .2-o!8' 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of th' jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat l:k COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permitsa-ci.wheatridae.co.us I FOR OFFICE USE ONLY I Date: I/ p l i Plan/Permit 01600 I a9 Plan Review Fee: Building Permit Application Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. Property Address: 7G / s' W • .1' k-1-4- 1-!� / o 5 - Property Owner (please print): 7 dcrc4 g ioeu ,c 244,45 Phone: S IS 2 6'<j - 1266 - Property Owner Email: /% %u R NE 2 /C u e- c a u I �7 Cv �► Mailing Address: (if different than property address) Address: City, State, Zip: Arch itect/Eng0neer: 12 /4-J/ s �Lo,y A S , r. -e -7 -S Architect/Engineer E-mail: J_C44 ®D,4x151 a NEsAach c#MPhone: 3 03 99 41- 3 ?(. b Contractor: D C- m . r-. c Contractors City License #: Phone: 303 - 472 -Gb8 V Contractor E-mail Address: rl ocl_- . L411'e.v s "Op en .y, i w c . cv For Plan Review Questions & Comments (please print): CONTACT NAME (please print): [fit Sub u4 11,j,r Phone: 3') % 4 7 2 - 6 S` � cL CONTACT EMAIL(p/ease print): &I, cllr_"�s F C o�•L ✓�-- Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # City License # Plumbing: W.R. City License # Other City Licensed Sub: Mechanical: W.R. City License # Complete all information on BOTH sides of this form ® COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) VE/Vit:, Qu79Aid2 (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) ,?9N7'.FJUOA v A IIS , J2f /M tJF 4A,' b <�-A 14 54�-E FlfA«n( proD ;) o Sq. Ft/LF g? 6 0 D Btu's Amps Squares Q la MA /'Vy fi V A G, Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) CONTRACTOR) Signature (first and last name): DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ COLORADO ASBESTOS INSPECTIONS Limited Asbestos Inspection Report 7615 W 38th Ave Suite B105, 13107, 8111 Wheat Ridge CO 80033 Report Date: 12/22/27 Prepared For: United Construction Company Marvin Turner 246 Wilson Pike Circle Brentwood, TN 37027 615-370-0740 mturner@uccbuild.com Prepared by: Colorado Asbestos Inspections 303 S Broadway, Unit 200-209 Denver, CO 80209 info@coasbestest.com 303-246-4587 Table of Contents 1.1 Project Summary 1.2 Homogenous Areas in Work Scope 1.3 Photo Log of ACM and/or Trace Materials (if identified) 1.4 Summary of Asbestos Samples Section 2 Recommendations Section 3 Project Overview Section 4 4.1 Asbestos Containing Materials (ACM) 4.2 Suspect Asbestos Containing Materials 4.3 General Comments Conclusion Appendix A: Drawing(s) B: Certifications C: Laboratory Report and Chain of Custody Form Section 1 1.1 Project summary Location/ Textured walls, floor tiles, cove base, carpet glue, joint compound and ceiling tiles in units B105, components 8107, and B111 inspected: Client: United Construction Company Inspector: James Durgee Consulting Firm # 19102 Inspector Cert # 16040 Inspection Date: 12/21/17 Scope: Partial renovation Building Commercial building (strip mall) Description: Date(s) of 1983 Laboratory: Reservoirs Environmental construction: NVLAP # 101896-0 1.2 Homogenous Areas in Work Scope Homogenous Areas in Work Scope Class= Material Classification: S=Surfacing Material, M=Miscellaneous, T=TSI `Quantities are estimates only and should not be used for bidding Group Class Material Location(s) 1 S White/tan smooth texture, drywall 8105 smooth textured walls 2 M Composite drywall Joint compound areas -Unit B105 3 M 2 x 4 dot/groove ceiling tiles 8105 ceiling tiles 4 M 2 x 4 dot/large groove ceiling tiles B105 ceiling tiles 5 M Brown over white 12" floor tiles B105 bathroom flooring 6 M White 12" floor tiles B105 flooring in closets 7 M 6" cove base, mastic B105 cove base areas 8 S Orange/red/green smooth texture, B107 textured walls drywall 9 M Composite drywall 10 M Yellow carpet glue 11 M White 2 x 4 ceiling tiles 12 M Cove base, mastic 13 M Yellow panel glue 14 S Green/white thick texture, drywall 15 M Composite drywall 16 M Composite drywall Joint compound areas -Unit B107 B107 below carpeting B107 ceiling tiles B107 cove base areas B107 bathroom wall panel areas B111 texture walls Joint compound areas/textured walls - B111 Bare drywall with joint compound - B111 Quantity Samples 2000 5 200 1 800 1 800 1 84 1 60 1 100 1 2000 5 100 1 800 1 800 1 100 1 300 1 1200 5 100 1 100 1 17 M 12" floor tiles/mastic Bathroom floor tiles -B111 160 1 18 M Carpet glue Below carpeting -B111 800 1 1.3 Photo Log of ACM and/or Trace Materials (if identified) None of the samples contain asbestos. 1.4 Summary of Asbestos Samples Bulk Sample and Locations Table Group Sample ID Sample Locations Condition Friable Result 1 SMW 1-1 B105 -Main room W wall, middle G NF 2 None detect 1 SMW 1-2 B105 -East room N wall, middle G NF 2 None detect 1 SMW 1-3 B105 -Water heater closet N wall, middle G NF 2 None detect 1 SMW 1-4 B105 -North hall 2' W of wall soffit G NF 2 None detect 1 SMW 1-5 B105 -Bathroom S wall, middle G NF 2 None detect 2 CDW 1-1 B105 -Main room NW corner G NF 1 None detect 3 CT 1-1 8105 -Main room Middle of ceiling G Yes None detect 4 CT 2-1 B105 -Main room Middle of ceiling G Yes None detect 5 FTM 1-1 B105 -Bathroom Floor -N end by door G NF 1 None detect 6 FTM 2-1 B1 05-N closet Floor by door G NF 1 None detect 7 CB 1-1 B105 -Bathroom N end by door G NF 2 None detect 8 SMW 2-1 B107 -Entry W wall, middle G NF 2 None detect 8 SMW 2-2 B107 -SW office E wall, middle G NF 2 None detect 8 SMW 2-3 B1 07-W middle office N wall, middle G NF 2 None detect 8 SMW 2-4 B107 -Bathroom N wall, middle G NF 2 None detect 8 SMW 2-5 8107-E middle office E wall, middle G NF 2 None detect 9 CDW 2-1 B1 07-W hall NW corner G NF1 None detect 10 FTM 3-1 B107 -Bathroom Floor by door G NF 1 None detect 11 CG 1-1 B1 07-E office Floor by door G NF 1 None detect 12 CT 3-1 B107 -Entry Middle of ceiling G NF 1 None detect 13 CB 2-1 B107 -SW office W wall, middle G NF 2 None detect 14 PG 1-1 B107 -Bathroom By door G NF 1 None detect 15 SMW 3-1 B111 -SW office S wall, middle G NF 2 None detect 15 SMW 3-2 B111 -SW office W wall, middle G NF 2 None detect 15 SMW 3-3 B111 -W middle room W wall, middle G NF 2 None detect 15 SMW 3-4 B111 -W middle room N will, middle G NF 2 None detect 15 SMW 3-5 6111 -Kitchen N wall, middle G NF 2 None detect 16 CDW 3-1 B111 -SW office SW corner G NF 1 None detect 17 CDW 4-1 13111-W wall Middle of W wall G NF 1 None detect 18 FTM 4-1 B111 -SW office Floor by door G NF 1 None detect 19 CG 2-1 B111 -Kitchen Floor by door G NF 1 None detect Condition: SD= Significantly Damaged, D= Damaged, G=Good Friable: NF1= Category 1 Non -Friable, NF2= Category 2 Non Friable Section 2 2.1 Recommendations No asbestos was identified in any of the samples that were collected. As per AHERA, a material is to be considered as asbestos containing unless it is proven otherwise by appropriate sampling. Please work safely and if you encounter any other suspect building materials not listed in this report, please contact Colorado Asbestos Inspections for additional sampling. Section 3 Project Overview Colorado Asbestos Inspections was contracted by the client to perform a limited asbestos inspection at the previously referenced address. This asbestos inspection was conducted by a Colorado State Certified Asbestos Building Inspector. The client is planning remodeling activities of the inspected areas in the property at the above mentioned address. Colorado Regulation #8 requires that all suspect Asbestos Containing Building Materials (ACBM) be properly sampled and analyzed prior to conducting any repair or renovation activities over the established trigger levels (32 sq. feet or 50 linear feet or the equivalent to a 55 gallon drum, for residential properties and 160 square ft, 260 linear feet for commercial properties). The purpose of this inspection was to identify and sample all suspect ACBM that may be disturbed during the course of the repair/renovation work. Section 4 Asbestos Inspection This asbestos inspection was conducted according to the United States Environmental Protection Agency (EPA) procedures published in 40 Code of Federal Regulations (CFR) Part 763, Subpart E - Asbestos -containing Materials in Schools and Colorado Regulation 8. These inspection protocols specify requirements for the inspector (Section 763.85), laboratory (Section 763.87), and number of samples collected during an inspection (Section 763.86). This inspection involved identification and sampling of suspect ACBM in the areas to be repaired or renovated. Suspect ACBM includes nearly all building materials except glass, metal, wood and ceramic. Bulk samples of suspect ACBM were collected in general conformance with AHERA protocols as outlined in Colorado Regulation 8. Random samples of suspect building materials were collected throughout each homogeneous area (see appendix A). Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker. 4.1 Asbestos Containing Materials Asbestos Containing Materials (ACM) contain asbestos in concentrations greater than 1 percent, (> 1% asbestos) as confirmed by an accredited laboratory. ACM is categorized as Non -friable or Friable asbestos. Non -friable asbestos is any material that cannot be crumbled, pulverized or reduced to a powder by hand pressure when dry. Friable asbestos can be crumbled, pulverized, or reduced to a powder by hand pressure when dry. Sample(s) were submitted under chain of custody procedures to an accredited laboratory for analysis by polarized light microscopy with dispersion staining techniques per EPA methodology (40 CFR 763, Subpart F). Microscopic visual estimation was used in obtaining the percentage of asbestos in bulk samples. The laboratory is accredited under the National Voluntary Laboratory Accreditation Program NVLAP. See appendix A for sample and laboratory summary and appendix C for laboratory report and chain of custody documents. 4.2 Suspect Asbestos Containing Materials Suspect ACBM are building materials historically known to contain asbestos and therefore suspected to contain asbestos. The EPA and the Occupational Safety and Health Administration (OSHA) maintain comprehensive lists of suspect ACBM frequently encountered during inspections. 4.3 General Comments This asbestos inspection was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our limited inspection of the areas in question. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the client for specific application to the project as discussed. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Colorado Asbestos Inspections does not warrant the work of regulatory agencies, laboratories or other third parties supplying information that may have been used in the preparation of this report. No warranty, express or implied is made. 4.4 Conclusion Colorado Asbestos Inspections has performed a limited asbestos inspection of the property previously referenced. Through laboratory analysis of bulk samples, Colorado Asbestos Inspections recommends hiring a certified asbestos abatement contractor only if asbestos containing materials were identified, as determined by laboratory testing and in Sections 1 & 2 of this report. Any work associated with any asbestos containing materials must be performed in accordance with all State and Federal Regulations. Reasonable effort was made by Colorado Asbestos Inspections to locate and sample accessible suspect building materials. However, for any structure, the existence of unique or concealed asbestos containing materials is a strong possibility. Colorado Asbestos Inspections only collected PLM bulk samples in the property's repair/renovation areas at the direction of the client. This limited asbestos inspection report is not considered a comprehensive asbestos inspection report. Respectfully Submitted, James Durgee Colorado State Certified Building Inspector: 16040 Consulting Firm: 19102 Colorado Asbestos Inspections, LLC. 303 S Broadway, Suite 200-209 Denver CO. 80209 Tel (303) 246 4587 info@coasbestest.com Appendix A: Drawing WEW�Epv l�ii'{tVlll)(a1[ td't'u61iCf kaldt andDwirommr ASBESTOS CERTIFICATION* -P,k c_ai t -ca l"mt James D. Durgee ccrtwmation ha.: 16140 bsa rtct rhe rcquir�y-lcno) aY?� -54?, CKS, aad Air Qualiib conuel C'oo uxiss:on Regulation No. R. Part R, and is hrnchy ce-h tied b, Ih.- su)tc ofcoiuredu iii :hc (OR)wing dLelprine: Building tnspc— tur* 1—d: Dm mbcr 86, 2017 Esplres: December OT, 2018 yJ n �.Ab ' �d+FM Sryvu«)iIR1 • SE?L (CC; 1111 AsIq,rw.UTiaining Zti ic�illit.)Un.. E.Fw_,f, ew9'. .- i."S IKaI Cs?4vsa�e fE`.516n CEn'i'� itn+M 4a�ae �.;.+uM, CERTIFICATE OF ACHIEVFV1FVT This Cep J=eisa.aardecto: JAMES DURGEE In recagnitior, at satisfacmry comPkrtbn astFe CFAaForc•«e� anrual asaestas �etresher trainingxurseuniarseacr 2C6ofihe-o&$absanc=GrrtrolActi; SCAt,Tt,elI fntl[IPd: HlllLDTNG I!VSPFCT0R WIRA31cN Lvn ;X7 -oma rt AM rxxaitFir MS 411 Appendix C: Laboratory Report and Chain of Custody Form Reservoirs Environmental, Inc. Effective January 1, 2015 Reservoirs Environmental QA Manual T\QAQC\Lab\Reservoirs Environmental QA Manual.doc REII LAB Reservoirs T_ En vironmen tal, Inc. December 22, 2017 Jim Durgee Colorado Asbestos Inspections 303 S. Broadway Suite 200-209 Denver CO 80209 Dear Customer, Subcontract Number: Laboratory Report: Project # / P.O. # Project Description: NA RES 397217-1 171221-1 B105, 8107.6111 Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 397217-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, Jeanne Spencer President P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 1 1-866-RESI-ENV w wv.reilab.com Reservoirs Environmental, Inc Reservoirs Environmental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 397217-1 Client: Colorado Asbestos Inspections Client Project Number / P.O.: 171221-1 Client Project Description: B105, B107.13111 Date Samples Received: December 21, 2017 Method: EPA 600/R-931116 - Short Report, Bulk Turnaround: 24 Hour Date Samples Analyzed: December 22, 2017 Effective January 1. 2015 Q'\QAQC\LAe\Reservoirs Environmental QA Manual doc ND=None Detected !TR=Trace. <1 % Visual Estimate Trem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E DescriptionEstimate R Asbestos Content Mineral Visual Non Asbestos Fibrous Components Non - Fibrous Components SMW1-1 EM 1994475 A White paint 5 NO 0 100 B White/tan drywall 95 ND 15 85 SMW1-2 EM 1994476 A White paint 5 ND 0 100 B White/tan drywall 95 ND 15 85 SMW1-3 EM 1994477 A White texture w/tan paint 5 ND 0 100 B White tape 5 ND 90 10 C White joint compound 5 ND 0 100 D White/tan drywall 85 ND 15 85 SMW 1-4 EM 1994478 A White paint w/ a trace of white texture 3 ND 0 100 B White/tan drywall 97 ND 15 85 SMW1-5 EM 1994479 A Tan/white paint 5 ND 0 100 B White/tan drywall 95 ND 15 85 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. 1 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-R=51 ENV F 303477-4275 —reilab com °age i of 6 Reservoirs EnvuonmentaL Inc Reservons Envnonmental OA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 397217-1 Client: Colorado Asbestos Inspections Client Project Number / P.O.: 171221-1 Client Project Description: B105, B107.13111 Date Samples Received: December 21, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 24 Hour Date Samples Analyzed: December 22, 2017 Effective January 1, 2015 0-\QAQC\tA8\Reservoirs Envnonmental QA Manual doc ND=None Detected -TR=Trace, <1%Visual Estimate Trem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R Asbestos Content Mineral Visual Estimate (/) Non Asbestos Fibrous Components ) Non - Fibrous Components (9e) CDW1-1 EM 1994480 A White tape 2 ND 90 10 B White joint compound 3 ND 0 100 C White texture w/ white paint 5 ND 0 100 D White/tan drywall 90 ND 15 85 CT1-1 EM 1994481 A Gray/white ceiling tile 100 ND 60 40 CT2-1 EM 1994482 A Gray/white ceiling tile 100 ND 60 40 FTM1-1 EM 1994483 A Black mastic 2 ND 0 100 B Tan mastic 2 ND 0 100 C Brown tile w/ colorless adhesive 40 ND 0 100 D White tile 56 ND 0 100 FTM2-1 EM 1994484 A Black mastic 5 ND 0 100 B Gray tile 95 ND 0 100 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P 303-9641986 5801 Logan Street, Suite 100. Denver, CO 80216 1-866-RESI-ENV F 303-477-4275 Rage 2 of 6 y,.M.y.rehab com Reservoirs Environmental Inc Re Dire Environmental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 397217.1 Client: Colorado Asbestos Inspections Client Project Number / P.O.: 171221-1 Client Project Description: B105, 6107.6111 Date Samples Received: December 21, 2017 Method: EPA 6001R-931116 - Short Report, Bulk Turnaround: 24 Hour Date Samples Analyzed: December 22, 2017 EHecnve January 1, 2015 Q'\QAQC\LAB\Reservoirs Environmental QA Manual doc IND=None Detected ITR=Trace, <1 % Visual Estimate I;Trem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R Asbestos Content Mineral Visual Estimate Non Asbestos Fibrous Components Non - Fibrous Components C131-1 EM 1994485 A Tan mastic 2 ND 0 100 B Cream cove base 98 ND 0 100 SMW2-1 EM 1994486 A Tan/multi-colored paint 3 ND 0 100 B White/tan drywall 97 ND 15 85 SMW2-2 EM 1994487 A Green/multi-colored paint w/ a trace of white texture 3 ND 0 100 B White/tan drywall 97 ND 15 85 SMW2-3 EM 1994488 A Tan/multi-colored paint 2 ND 0 100 B White/tan drywall 98 ND 15 85 SMW2-4 EM 1994489 A White texture w/ blue paint 5 ND 0 100 B White texture w/ pink paint 5 ND 0 100 C White/tan drywall 90 ND 15 85 SMW2-5 EM 1994490 A Tan/multi-colored paint 3 ND 0 100 B White/tan drywall 97 ND 15 1 85 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P 303-964-1986 5801 Logan Street Suite 100, Denver, CO 80215 1-865-RESI-ENV F- 303477-0275 Page 3 of 6 vvvev railab cram Reservoirs Environmental Inc Reservoirs Environmental CIA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 397217-1 Client: Colorado Asbestos Inspections Client Project Number / P.O.: 171221-1 Client Project Description: 8105, B107.B111 Date Samples Received: December 21, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 24 Hour Date Samples Analyzed: December 22, 2017 Effective January i, 2015 O.\QAQC\LAB\Reservoirs Environmental OA Manual doc :ND=None Detected TR=Trace, 11% Visual Estimate + Trem/Act=Tremolite/Actinolite Client Sample NumberY Lab ID Number L A Sub Physical Part E Description R (%) Asbestos Content Mineral Visual Estimate (%) Non Asbestos Fibrous Components (%) Non - Fibrous Components (%) CDW2-1 EM 1994491 A White tape 2 ND 90 10 B White joint compound 2 ND 0 100 C White compound w/ tan paint 5 ND 0 100 D White/tan drywall 91 ND 15 85 FTM3-1 EM 1994492 A Tan mastic w/ gray debris 5 ND 0 100 B White/multi-colored tile 95 ND 0 100 CG1-1 EM 1994493 A Tan mastic 10 ND 0 100 B Gray foam 90 ND 0 100 CT3-1 EM 1994494 A Gray/white ceiling tile 100 ND 60 40 CB2-1 EM 1994495 A Tan mastic 10 ND 0 100 B Tan cove base 90 ND 0 100 PG1-1 EM 1994496 A Tan mastic 50 ND 0 100 B White/pink paint w/ white compound 50 ND 0 100 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P 303-964-1986 5801 Logan Sneet Suite 100 Denver, CO 80216 1-856-RESI-ENV F 303477-4275 Page 4 of 6 —rehab com Reservoirs Environmental, Inc. Reservoirs Environmental CA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 397217-1 Client: Colorado Asbestos Inspections Client Project Number / P.O.: 171221-1 Client Project Description: B105, B107.13111 Date Samples Received: December 21, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 24 Hour Date Samples Analyzed: December 22, 2017 Effective January 1, 2015 C \CACC\LAB\Reservoirs Environmental CA Manualdoc ND=None Detected !TR=Trace, <1% Visual Estimate ( Trem/Act=Tremolite/Actinolite Client Sample Number Lab ID Number L A Sub Y Physical Part E Description R Asbestos Content Mineral Visual Estimate Non Asbestos Fibrous Components Non - Fibrous Components Si EM 1994497 A White texture w/ white paint 5 ND 0 100 B White/tan drywall 95 ND 15 85 SMW3-2 EM 1994498 A White texture w/ white paint 5 ND 0 100 B White/tan drywall 95 ND 15 85 SMW3-3 EM 1994499 A White texture w/ green paint 5 ND 0 100 B White/tan drywall 95 ND 15 85 SMW3-4 EM 1994500 A White texture w/ green paint 5 ND 0 100 B White/tan drywall 95 ND 15 85 SMW3-5 EM 1994501 A White paint 3 ND 0 100 B White texture w/ white paint 5 ND 0 100 C White/tan drywall 92 ND 15 85 CDW3-1 EM 1994502 A White texture w/ white paint 5 ND 0 100 B White/tan drywall 95 ND 15 85 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1 %. P 303-964-1986 5801 Logan Street. Suite 100, Denver, CO 80216 1-866-RESI-ENV F 303-477-4275 Page 5 of6 www r eilab com Reservoirs Envnonmental, Inc. Reservoirs Environmental QA Manual RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: RES 397217-1 Client: Colorado Asbestos Inspections Client Project Number / P.O.: 171221-1 Client Project Description: B105, B107.6111 Date Samples Received: December 21, 2017 Method: EPA 600/R-93/116 - Short Report, Bulk Turnaround: 24 Hour Date Samples Analyzed: December 22, 2017 Effective January 1, 2015 Q \nAOC\LAB\Reservoirs Environmental OA Manual. floc ,ND=None Detected ITR=Trace, 11% Visual Estimate Trem/Act=Tremolite/Actinolite Client Lab L Asbestos Content Non Non - Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R CDW4-1 EM 1994503 A White compound w/ yellow fibrous woven material 5 ND 0 100 B White compound w/ yellow fibrous woven material 5 ND 5 95 C White/tan drywall 90 ND 15 85 FTM4-1 EM 1994504 A Yellow mastic TR ND 0 100 B Gray tile 100 ND 0 100 CG2-1 (labeled as 1-1) EM 1994505 A Tan adhesive w/ gray debris 100 ND 5 95 TEM Analysis recommended for organically bound material (i.e. floortile) if PLM results are <1%. Any, Analyst / Data QA P 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI ENV F- 303-477-4275 — reilabcom image 5 of 6 �� �j� ��.8 e5c-�r-vvirs Er�virv�-se•'s-serst�/. /mac_ RES 39727 ue Dat8'.,•-•1---'�'— saB,�-- secs tn�N r.� a..+°` co eza:< rn. ao:> �„e.,,nsa • F„:wr.�n .>'ss . r,ay.,e aae mss!-bvv ue Time _-- Artw Call Plh . 720s3"222 COMCT INFORMATION. INyOiQE TO: IF DIFtERENT -^ 303_2464587 �ctlons ._ - c Golorad?As -.----.-- --__ 209 ..... _ .. ....... _. -303 � BrvedweY - ._.... - .. _... 200- _ _..... cdua• co - - tlur 'imp maik;Om _.... �,�,,,,eevo • J %/Z Z �., e- /7 a REQUESTED ANALYSIS YALJD MATROC CODES LAB NOTES: . ..... Weakd lam -T m TOS LABORATORY HOURS: 4ay1— PRIORIT,• M—STAPIOARO i ( _ _ . Duff 0 P RUSH (Same TEM aBM-1 i .. $.. �'w LII ITEM (Rush PCM =2115 i I _. _... _.. N kda s: Sam . spin - LABORATORY 3-5 Day t � CHEMISTRY 6AB RY HOURS: We" RUSH — 24 N ._per nvelle+bn : i I 44i _ _ OWa VV- Kr 1YN Yebdis)! Dust fuaw RUSH ._.5 daY X10 doV RCRA 81 Metal 6 Ylemat9 o• i .' ? ; Q nl7CU' _24 M. _34aY —5 OW ffi I AE.co11. L M a 4a_R pganka HOURS: Weekd . 2 bSpmDy .3-5 �Day 24 hr MICROBOLOGLASORA_W_€ �g Ei - ac Owmun� 8 g a, E.d6TH7. C48H3 DaTAPC. Y U21 H S. e0s,tsos .... om MEM Numt>�vbmal v DateDate9 qg5 q¢ + All - r f Collected 'ram SPaiW WtrucUanf: /^ TR• �-{ �" 7; ,1 a�'�l_ bamaeofocr z: •�+uM e,e..w IDY Mal he Client sarn laiDnOrllbK '� 1-- k I r-3 �.. 3 �� , ........ 4 S_ - --.. ..._.. _. B C _ �+ _ .... _:.._. _...... .. : i 9 ��%a'l �.-.�•.• ' .. .. •.•.•.•. n•a,e ga�aitubdnmdee ean>Ibf bdpumE d�.YobfvYem e�. ,�+^ •f7]'' •.. Tool) Nu'dMrde+°�rs '. �a,ar,a p�p.parfe eddme mel6x ,edaraYm.r e.mnoa eW nvu^'C°"n'M" �MrE13P4M.WY.nabI+R OM��etwa�'rwWi ��'JYa+yw•y Res --..AWAO- Environmental.'*U74u- L-^0 OW1. -103 V E— lopp-- RES Job Page 2 of Submitted by: ;4= 7-2D11vsrsiOn I REQUESTED ANALYSIS VALID MATRUt. CODES LAS NOTES: Ak-A BLdk - 0 Dusl - 0 Pm - p ' S VAPO w : S.8b Sw F a Food Drraanp Water -Dw V"OWater .vm wov- b Da. Taro Cafteled CoNecMd EM MUMbK (LbWmV MICK08MOGY 77L 7 ,7 7 Sao 7-2D11vsrsiOn I City of Wheat Ridge Comm. Tenant Finish PERMIT - 201702201 PERMIT NO: 201702201 ISSUED: 07/27/2017 JOB ADDRESS: 7615 W 38th AVE B103 EXPIRES: 07/27/2018 JOB DESCRIPTION: Tenant improvement: Modify wall to create one larger office and one smaller office from two same sized offices - 1,026 sq ft *** CONTACTS *** OWNER (303)796-8288 DPC DEVELOPMENT GC (303)778-8555 Alan P. Waring 060220 A&B Builders, Inc. SUB (303)778-8555 Alan P. Waring 060220 A&B Builders, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,157.00 FEES Total Valuation 0.00 Plan Review Fee 91.59 Use Tax 108.30 Permit Fee 140.90 ** TOTAL ** 340.79 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at. Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. 16 -'r l IN ECTION RECORD PECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection r2SCancellations INSPECTION REQUEST LINE: (303) 234-5933 must be submitted via the online form before 8 a.m. the day of the inspection Do Not Pour Concrete Prior To Approval Of The Above Inspections Undergro nd/Slab Inspections Date Inspector Initials Comments Inspections will not be performed unless this card is posted on the project site, **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete En Ground (CEG) _ Foun on / P.E. Lette Do Not Pour Concrete Prior To Approval Of The Above Inspections Undergro nd/Slab Inspections Date Inspector Initials Comments E ri Se er ice lumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections ROL gh :nspections Date Inspector Comments Initials �AEaIrSt�hrirre� mid-k�ae# Rough Electric " Rough Framing 3awgwer3tiirt0 FG+ r Drywall Screw / Nail Final Inspections L ,�r�jp��.�hlir \�InrkC Want, nspec ion i app ica le) Fire Inspection / Fire Protection Dist. Final Electrical ing -Roof Final Building 5. 11, 1 -1 � V,#-- iP1R-t��l (� $ 3 3 A -M, b • PS, R•#"-- I W C-o�tIO 10 32 b.AA Date Inspector Comments Initials Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. `For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Comm. Tenant Finish PERMIT - 201702201 PERMIT NO: 201702201 ISSUED: 07/27/2017 JOB ADDRESS: 7615 W 38th AVE B103 EXPIRES: 07/27/2018 JOB DESCRIPTION: Tenant improvement: Modify wall to create one larger office and one smaller office from two same sized offices - 1,026 sq ft *** CONTACTS *** OWNER (303)796-8288 DPC DEVELOPMENT GC (303)778-8555 Alan P. Waring 060220 A&B Builders, Inc. SUB (303)778-8555 Alan P. Waring 060220 A&B Builders, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,157.00 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. FEES Total Valuation 0.00 Plan Review Fee 91.59 Use Tax 108.30 Permit Fee 140.90 ** TOTAL ** 340.79 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. City of Wheat Ridge Comm. Tenant Finish PERMIT - 201702201 PERMIT NO: 201702201 ISSUED: 07/27/2017 JOB ADDRESS: 7615 W 38th AVE B103 EXPIRES: 07/27/2018 JOB DESCRIPTION: Tenant improvement: Modify wall to create one larger office and one smaller office from two same sized offices - 1,026 sq ft I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorised by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or C�TRACTOR (Circle one) Date I . This permit was issued base on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees andprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting ermit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any Adi a e or r_egul f thi uri diction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Cityof Wh6ad COMM UN I rY Df--VELOPMLNT _,ge Building & Inspection Services Division 7500 W. 29' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: 1-1 PlanlPermit 0) R/] I Plan Review Fee: r n ➢ Building Permit Application " Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed.... Property Address:, -. n 5 W, 3 6'" Property Owner (please print): VV C �Dr, -*4 C-.,, - 7q 6 - 6 2-66 VV_ L.0( JT Phone: �3oa Property Owner Email: Mailing Address: (if different than property address) Address: q-ioc) E L00H A4JL,:-t�eDD City, State, Zip., 11 C& eL)23-�- ArchltecVEnaineer: \/-/P( AO60s Architect/Engineer E-mail: Contractor: e-�jp, 'OUIL,96p-S 1 M•Wllwlwwll --- Contractors City License to ol-Z-o-- -?q �) - e SS -5 Phone:363 Contractor E-mail Address: Sub Contractors: Electrical: FFA e '?,UILV6gS- W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form f3e2cription of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING RESDENTIAL ADDITION [] WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT Q'bTHEIR (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 'ice-1A1-Y� I l✓►P(L t9Vi'c M C -I I� i t-A0b1Jr-\/ Y -I ft — --To c r,6 � 00t,:- ueg�c I' 1 Lc:7 V R,t,6r- Obi C�G, 62��-\ -nti-I 6 sl oq&- S?ZW OT 0�-71 Sq. Ft./LF 10 2AP Btu's Amps Squares Gallons Other Project Value; (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE OXE.- (0W'NER2) ETRACTCI"r (AUTHOPiZEDREFR£SENTATIp) of ((1HINER) (CONTRACTOR) PRINT NAME: ZONING COMMMENTS Reviewer BUILDING DEPARTMENT COMMENTS' Reviewer PUBLIC WORKS COMMENTS Reviewer: PROD OF, SUBMISSION FORMS SIGNATURE: Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received 0 Not Required DEPARTMENT USE ONLY DATE: (a.1 191 J7 OCCUPANCY CLASSIFICATION; Building Division Valuation: $ Robin Easterly From: Mackey, Melissa <mmackey@westmetrofire.org> Sent: Monday, June 19, 2017 2:53 PM To: Robin Easterly Subject: 7615 W. 38th Ave. B103 - REVISED Your plans have been accepted and are in the OTC queue. A plans examiner will contact the email address listed on the Plan Review Submittal Form once the plans have been reviewed. Turnaround time for over-the-counter permits is 3 business days from the date our office receives the complete packet. Regards, West Metro Fire Rescue Life Safety Plan Review Desk West Mei 1C'C3 Fire Rescue City of A ?Wheat�dge COMMUNITY DEVELOPMENT Project Address: --?(, ) 5 X1. 36-01 Aqt Permit #: General Contractor:p S g uLb r,(2s L I Electrical Contractor I Company e:%3LI Phone #: 3c, � 6 - 655 'Y Stat U #:f .-S01bogy 2 Master #: t-fE,Do,?c>�q2 Signature of Authorized Agent Date Plumbing Contractor Company Name: State License #:_ Wheat Ridge License #: Signature of Authorized Agent Mechanical Contractor Phone #: Master 9: Company Name: Phone: Wheat Ridge License #: Signature of Authorized Agent Date *This application must be signed by each sub -contractor confirming the same. PERNi1T:&CA'1 1`" ADDRESS: (I >W_3_ 1 f) �`JOB CODE. INSPECTION RECOR , �c� l Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underpround Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Ins to Initial' Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 402 Gas Meter Release 317 Rough Mechanical Commercial 403 Final Electrical Residential 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail L / j7 1,&, 321 Moisture board / shower walls 406 Final Mechanical Commercial 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Finai Roof 1410 Final Window/Door 1411 Landscape/Park/Planning _ Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection - 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. City of Wheat Ridge Commercial Roofing PERMIT - 201708563 PERMIT NO: 201708563 ISSUED: 10/24/2017 JOB ADDRESS: 7615 W 38th AVE EXPIRES: 10/24/2018 JOB DESCRIPTION: Commercial reroof recover 2 layers of EPS, one flat and one tapered, layer of flat ISO with Carlisle TPO 60mil membrane mechanically attached. 254.72sq *** CONTACTS *** OWNER (303)796-8288 DPC COMPANIES SUB (847)581-3888 John D. Cook 018520 Tecta America Colorado LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 330 / General Retail BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 295,262.00 FEES Total Valuation 0.00 Use Tax 6,200.50 Permit Fee 2,396.25 ** TOTAL ** 8,596.75 *** COMMENTS *** *** CONDITIONS *** In order to pass a final inspection on commercial elastomeric or similar type roofing, 3 letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accorda:ice the installation instruction for (roof material brand name) roof covering" is required be on site at the time of final inspection. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof. sheathing (new or overlay) is required on the entire rocf when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and Mid -roof inspections may be called in at the same time, 100 percent of the sheathing must be complete and 25-75 percent of the midroof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. City of Wheat Ridge j d Commercial Roofing PERMIT - 201708563 PERMIT NO: 201708563 ISSUED: 10/24/2017 JOB ADDRESS: 7615 W 38th AVE EXPIRES: 10/24/2018 JOB DESCRIPTION: Commercial reroof recover 2 layers of EPS, one flat and one tapered, 1 layer of flat ISO with Carlisle TPO 60mi1 membrane mechanically attached. 254.72sq 'b y my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications. applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in cunjunetiun th this ermit. I further attest that I am Iee��a11y authorized to include all entities named within this document as parties to the work -to be performed and that all wor�to b�p�rfprmed is disclosed in this document and/or its' accompanying approved plans and specifications Signatu o OWNER o ONTRACTOR (Circle one) Date I. This rmit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing' and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief BuiIdinL, Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, anew permit maybe required to be obtained. Issuance of anew permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chie i ding Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUS117SS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat f�,jdgie COMMUNIII' DLVLLOI'MLNT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits{a�ci.wheatridge.co.us I FOR OFFICE USE ONLY Date: 16147 -VII Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 7615 W. 38th Ave., Wheat Ridge, CO 80033 Property Owner (please print): DPC Companies Inc Phone: 303-796-8288 Property Owner Email: _ id,ire@dpccompanies.com Mailing Address: (if different than property address) Address: 7800 E. Union Ave. Ste 800 City, State, Zip: Denver CO 80237 Arch itect/Enaineer: N/A Architect/Engineer E-mail: Phone: Contractor: Tecta America Colorado LLC Contractors City License #: -5969-- (} a L Phone: 303-573-5953 Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Ilison@tectaamerica.com Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ® COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ® COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Roof recover - 2 layers of EPS, one flat and one tapered, 1 layer of flat ISO with Carlisle TPO 60 mil membrane mechanically attached. Sq. Ft./LF 25472 Btu's Gallons Amps Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) S 295,262.00 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED PRESENTATIVE) of (ORNER) (CONTRACTOR) C t C Electronic Signature (first and last name): � { � i ,l DATE: a ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: P5LDCA r- l a 4 L Job Address: IU 1 5', :2)16TA 4t4 E_ til D3 Permit Number: "2,00 0 S7,0 ❑ No one available for inspection: Time ( M Re -Inspection required: Yes No When corrections have been made, call fo-inspec`tio�n at 303-234-5933 Date: 1,C) Zo Inspector: `� c DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE Building Inspection Division (3 03) 234-5933 inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION7-S ICE Inspection Type: �Zj w�1("�-� << y w Job Address: Permit Number: ❑ No one available for inspection Re -Inspection required: YesNo When co%rr ec }tions have been made, call for re -inspection Date:./ (1-,/ 6- / Inspector:_ AM/PM i CITY`OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION %% NOTICE Inspection Type: j!` �'"� ��� `//" Job Address: G%��� t,! �c�i�?� /4/01/ Permit Number: 0 ❑ No one available for inspection: Time // ' C/ AM/PM Re -Inspection required: Ye' o A When corrections have been made, call for re-insp' bio t303-234-5933 Date: i- Inspector: DO NOT REMOV THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 404- (CM Job Address: -;�&1 `J A ve- Permit Number: -2_0 1-702 Z6 1 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: /0- InspectoGr� - DO NOT REMOVE:THIS NOTICE I� r O rn M ro w hj ►h M• DD O ( M O a rr H P. F-' M n b. Fi m (D rrrr P) m a m .r E rr C2 'r m M .�1 cI H � m H m O rrr r M �Hrr tQ N m tr 0 O N. F-� M H W H O z 'j. rr v O r+ rr b1 Y y H 0 N m r - w p b E3 a z (D C�C C tri G r- m ~ roy m m z w a K N rIw 0 w 0 PC 13 a � m M K o m p n ro M 0 H m p w a m w E O m m p ry M- M b µ K '00 m x m I K W f" rt K a m 7 ro n m b G " a P. w w m p a r W E n ° p o n a m "c n w m rt tr o E W C rr H a � � M C o � m H m K w ro m K O m p, °m m wm m a m m 0 M m µ p m 0 �- O r a a m w N d p w o H P, ro O 3 rt w p m m m H m m C r p w m K m m H a K a m 0 a w tor c° m q m m VaId rr b Fj rwr N. O d O 0 ro �' f'S � N O (D n to 0 w O r rt P- r M 0 tr. " m m 0 a � rr ((D N m 0 m P. f] 'r m M H � m O H rpt H M rdcr C1] W 0 ~ N m tr n N. tAJ r H H zz �. rr v O 0 rr Im v v n c 'a b H K J Xk K O K tA o yx O Stl t7 C $ N M d 6Z] w N c V r m 3 O m 2 0 w � Gr O o � ~ co $ m c w p � n F1 t N K N n CCDtl G a M C 0 N xb y w p K O N H H to n U) C, y 0 a m x � m Nrt n m p h o rr o w m " n p a r PP(D. E o m m p " W rn j r* .°d m m n F K K 0 m w rn n (D "rr c m m "- a a r w m p E p o o n p m r g n a n M m K � a n E � Crr " ro x N- n art � rn p � m m " m m rt 0 m Ir o G w O m p, m m w m m a m ro w o n rG rn m a w rr n �- w a o a W O " a b o 5 rt"• .7 m mm " m m m w m c* m a " rr r 7 a m p a a 0 a o m m m m ro b Fj H rar N. 7 N a O V O D O ^ O \ 1 r• fi D i 0 �0 y r tj p 0 y off" O W W i Du O O y O d A� C'r fD O OD \ O J N O N J i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 1:: �_- 12— 1 Job Address: 76/5� !,✓ 38 h ✓e 6/©� Permit Number: 90 170 2Q l Q_LILLA 14 L-5 ❑ No one available for inspection: Time M M Re -Inspection required: Yes '�No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE I* � l i CITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 9 I Q Permit Number: "Z,o 1'1 Q'�Z Q ❑ No one available for inspection: Time `' P7 (4>/M Re -Inspection required: Yes ��O When corrections have been made, call for re -inspection at 303-234- Date:- 115 / 11 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE -.A Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F_1� .L(N e" Job Address: r5— W 3 Ayt CJyr ffl©l Permit Number: �k O/ d0,V73 ❑ No one available for inspection: -Time AM/PM r. Re -Inspection required: Yes (VNo -s When corrections have been made, call forre-insp tion at 303-234-5933 Date: Inspector: /,0 ! ,� '� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 15 Fl. 15 I"- I Job Address: 7 & 15' Permit Number: Z01'2070 (2 ❑ No one available for inspection: Time I •"v!! (PPM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: 5)z3)1'2 Inspector: 110" DO NOT REMO THIS NOTICE 3 F CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: AbKSA.MFI, PFI t5FI Job Address: eA 6 10 1 Permit Number: 1 -;-Fl - n/&Z-V e" ff /VIV M ✓L'r,/ 6F/ - ain`te 5-11 !^f1tL- ❑ No one available for inspection: Time 1 -'349 /PM Re -Inspection required:�No *When corrections have been made, call for re -inspection at 303-234-5933 Date: 5,116 Inspector: OL6_W_1�2� DO NOT REMOVE THIS NOTICE 14, CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F® ) Job � Address: :7(0)G,NN3��r- IQI a 1 C) Permit Number: Zbl'1 QO l&U T- er—v S�7 ❑ No one available for inspection: Time r2-'ZA Re -Inspection required: Yeso *When corrections have been made, call for re -inspection at 303-234-5933 Date: 6/ Inspector: Ar' DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M /J Job Address: ''1Gl5 W 3?t"4 vt 6101 Permit Number: Z01 7 0ogV 6,q ,l t412 3,-, 1 TG ❑ No one available for inspection: Time ,'0) A Re -Inspection required: CWNo *When corrections have been made, call for re -inspection at 303-234-5933 Date: 5114011-2 Inspector: 4� WA DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ) dJ 4S . ! Job Address: 7� / T w "3 c. Permit Number: t I '7 G G G (� �1 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date:`` 3' ' j r` Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Sign PERMIT - 201700473 PERMIT NO: 201700473 ISSUED: 04/07/2017 JOB ADDRESS: 7615 W 38th AVE UNIT B101 EXPIRES: 04/07/2018 JOB DESCRIPTION: Fabricate one new 91.65 sq ft illuminated replacement sign for west elevation *** CONTACTS *** OWNER DPC DEVELOPMENT COMPANY SUB (303)726-5015 Curt Marcolina 110193 CDM Signs *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 333 / BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,652.00 FEES Total Valuation 0.00 Pian Review Fee 132.80 ■ Use Tax 173.74 ki Permit Fee 204.30 ** TOTAL ** 510.84 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable bu' ing codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal ner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permi . l rther attest that I m legally authorized to include all entities named within this document as parties to the work to be perform a d tha�tayll wor to b erformed is disclosed in this document and/or its accompanying approved plans and specifications. 1. t ms permit was issuea oasea on-tue.-trtarmauon proviaea in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief Building Official 17 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of W heat j ge COMMUNITY DEVELOI'MEN7 Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits .ci.wheatridge.co.us r r� FOR OFFICE USE ONLY Date: 4-/ ]/ f/ Plan/Permit # D ) Zoq_? Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 2615 G l ,? y- -�_b a 1./ �L', & i Q I Property Owner (please print): Qr �/��; jtPrn� j ± �� � (� �a_/f��,J Phone: 3vj-79 � d�ed0, Property Owner Email: 7 SS' 0; %'(mac J lit" ' (� G >�f �r1 �P, 5 . Ca. ►� Mailing Address: (if different than property address) Address: '7100 E' �C G i/,c h/ Sll � 00 City, State, Zip: �/i �'�c ✓V,0 Architect/Engineer: Arch itectlEngineer E-mail: Phone: Contractor: Contractors City License #: l Phone: T 6 J f 2%� JU/ J Contractor E-mail Address: clrLN 4_) F Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT OTHER (Describe) �(r-O )CEf'4 6,J'M&*Jd (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or UTHORIZED REPRESENTATIof (OWNER) (CONTRACTOR) Electronic Signature (first and last name): ^�y� /C—_ DATE: ZONINGCOMMMENTS: Reviewer: \ /k BUILDING DEPARTMENT COMMENTS: Reviewer: L41_711-7 DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ 4t7 %I city of CoM .� MUMW 0rALWMIENT APPROVED Reviewed for CobCompi :nce PIME, nate Va1iQkYdrltl:ltttilr/��M/AI#OroOprwnr, onecomputotlonsN nWAv*p Wjbr oro^aper any of the PMW$bmM1M1MWOMS& M of ons•'?, r 1 ., presuming to qhV MIAMjWIMgb%W4jCdWCl Mr r• -.suns cl r`i r emq lodes or~ordbw / dfwOWSWnot be voki }� APPROVED y. DATE: C®1lwNT : -�ri7Z 6'! S G✓, ✓✓�- � APPROVED BY. DATE: - - COMN ENT"S: T U O2X> 1 m m 3 0 g oao� z G O>z S�OInaC Z ,?.� � eeeeeearrrrrr111l11 m O =90'a -i r^ ti0 o-q,z pZ�y�° so ��� N7, Fo' zn Mccm cn y C m O o O F r z �nz y -I D Om ym m o � n E zZ zo c O > z K N m � mo rGG"CD��ik�N CC= 0 N W C RIm3�n, a'om MXEM-*cv mmc;6=XM mM>zmmmc g*w-izpyM DD0>rmO[y mm§rrmym �,cDi3m*m0 z oamzz=Nv o DD_ >0 zo<O�'m c n 2= mr O go Dy mvOz ❑� mmrm MN. a. mD CMm �u WD <-�f2M71 zm 6mrai m z O 0 m A a m. mA MK N D v 3 W o= `G 9 ao n o E F O = O � w � a 9 O 7 0 \srccONM,m Oct �C<f3i1DD0 =A M->�5m ao o�Zm?R Z Ommr�* ??nCC 3c 20co 4 c � m -b O -Cva 0� 0 ZK m0 �F A O O o p� D Am z Sa vm v �» r ry y Oy h o� qz m o R M, m m Hi m N 5. X N z> y a. Z n � z 0 30 H� m m m a dv i N X m o z 0 a� 0 m A= U Z o _ n r = m r i� O n` o n � ❑ b po Q u 0O y0 0 Z ~ a - � o o : S jlm _7_p ty Y,00 0 V �. Or 3m C 0 m z m Z y _ x O vZ D _D > r n J m : i O m i p O i m O D 0 '9 O < O { < z * m m o v°° 1 mQ A o O C z c m Ac o w O v m mGO w _ { `e D m < 2 A �N Z O O DZ rm x � mN 24" - ® 18" Z _K z M z rr9 1 Ll i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303)235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: f::, P + fy1 / IP Job Address: -7 !,n / �_ 4-J _� � 4 A V r ! D Permit Number: 'i b (-, n L V 2i5k,rP ich.up-o vP,;dv e4V i�k I b ❑ No one available for inspection: Time 1 -S AM/PM Re -Inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Date: 7- Inspector: DO NOT REMOVE}THIS NOTICE 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: EL - r, Job Address: 15 ' ICS Permit Number: W01k �n ❑ No one available for inspection: Time OM/M Re -Inspection required: Yes No When corrections have been made, ca�)L)CiV)f lll 17a&t/for re-inspectionat 303-234-5933 Date: - 9 "� Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE ' Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: V,:�ec_A- `► a 1 Job Address: V 7ID15' UV. 38 "F4ye- ❑ No one available for inspection: Time "CD C� M Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: x%7 -1r inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: P u �- Job Address: "� l- t �" w 73 -A +� � Permit Number: . t '? b Q 0 � =/ CPR uL.00 ❑ No one available for inspection: Time `3, ' g -D AM/PM Re -Inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Date: ,f �l Inspector: t DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division I� (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L3 Job Address: 76 15 14/. 3 ��r Li r" R/o/ Permit Number: 2-01 Go 7-1Ajc U0 IOJPF. ❑ No one available for inspection: TimeZ� ACJ Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: .S- Inspector::2<.� DO NOT REMOVE THIS NOTICE O n 'd a M � N m O rt � p "x o w rt r w r M 0 a M m m rtap, mafD n 0 r• wm C] � m H 4 H f0 m H O Mrt r^ ry P. 0 r• m m n txjro r a H � H O z �. n 0 CT o ro z o °ro 0 Y w O io CSV C7 H W V1 .ro W U1 N N N ofr I H m 0 0 w r o m w 0 m R m C N 00 ro O ct S n rt m n rt m r m a E o m p m m ry N O ro ry w w � ro m O ^ w - rt ro rt J 1 0 n rom rt x m m m y a w rt N CL 0 IQE m ° ° a a m m p �� a rt m c ro0 ID a H� 0 �� y " a 0 a d o � fO7 �r(y1 •'C G0 (D rt x mO C) N � !G O O I� a 0 m y Z y] m tr rt O O W C m a 10 m W O m m m m m °' 00 lV o w ro O 0 w a ~ m a w m a otT .: a JI y N go p w O G m O ry a m �Mp P) ct o rt w V ID m m ry ry r m m O W P, m' \ a r P. R m m 0) \ N CL m g m< O m m �] /1) i r 1 1 -X-,44. A � n I 1 /1 i --7) Id /10i W. -Dd, 71�a/ INSP&T16 IRECORD Occupancv/" ype U n �t 13g)) g o YZ,4NSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day. * * Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date inspector Initials Comments Pier Concrete Encased Ground (CEG) Fire Inspection / Fire Protection Dist. Foundation / P.E. Letter r� Underground/Slab Inspections Date Inspector Comments Initials Electrical _ JY1G�� 1 t -24- i7 p c-4 Sewer Service Plumbing _ ----- 6'f le ,, I . i 2 4—r7 ' U Wip •` ON +': M- 111#T:- . t ..:[+Z'i= MIJ[6T&tW_3• - N • - a Rough Inspections Date Inspector Initials Comments Wail Sheathing Y _ Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. -Roof Fire Inspection / Fire Protection Dist. _Mid Lath / Wall Tie r� Final Electrical _ Rough Electric' I Ate. ��i li se = z� l �- Z-� -7 U- ll s Rough Plumbing/Gas Line %- f Final Mechanical i 5-13 Rough IMlechanical M Rough Framing � g /.-Yo-t- JL4 —� I Insulation Final Building — jl Drywall Screw/ Nail /' NOTE. All items must be completed and approved by Planning, Public Forks, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Final Inspections Date Ins ctor Initials Comments Landscaping & Parking / Planning Dept. _ Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. -- ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. 3-/s-/1 r� Final Electrical Final Plumbing Final Mechanical i 5-13 � q Roof Fina! Window/Doors Final Building r'7 NOTE. All items must be completed and approved by Planning, Public Forks, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. **For Inspection Time Window Requests — Please email insptimereauest@ci.wheatridae.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. 03/06/17 Or Current Owner/Occupant DPC DEVELOPMENT COMPANY 7615 W 38TH AVE UNIT #B113 WHEAT RIDGE CO 80033 Regarding Permit: 201600017; Install 1 wall lighted sign. Existing electrical. 7615 W 38th AVE UNIT #B113, Wheat Ridge, CO 80033 Dear PERMIT HOLDER: Our Records indicate that the above noted permit was issued on 01/07/16. Our last inspection related to that permit was on NONE. The permit expired as of 01/06/17 Please contact our office within one week from the date of this letter to update us on the status of this permit, or call for a final inspection on the property. You may call 303-234-5933 or request inspections online at www.ci.wheatridge.co.us. Information needed are permit number, property address, type of inspection and date to be inspected. If the permit is not extended before March 31, 2017, the permit will become void. If you do not contact this office, and wish to resume work at a later date, you will be required to submit a new permit application, drawings with appropriate code edition information and pay applicable fees. Incomplete or inactive permits may be reported to agencies such as Jefferson County Assessor, title companies, etc., and could affect future transactions related to this property. Thank you for your cooperation concerning this matter. If we can answer any questions, please don't hesitate to contact us at 303-235-2855, option 7. Sincerely, Wheat Ridge Building Division Staff NIXIE sea BE 1 RETURN TO SENDER A.-rri=pzp-rE1-1 - NOT KNOWN U*i��:?,,Llt:, TO FORIWARD SZQ33200100 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:_ l Job Address: 7 to 15 N 3 h v F UN 1 T c 10 1 Permit Number: c el i k ❑ No one available for inspection: Time ` _ A PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 6 Date: Inspector:` F, DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE j Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: & «f Job Address: ?U5 L. 3 60- Permit Number: 0 .'Y(f4,C 'S �4 ❑ No one available for inspection: Time M M Re -Inspection required: Yes _ No When corrections have been made, call for re -inspection at 303-234-5933 Date:- " N Ins ector: 4b DO NOT REMOVE THIS NOTICE e `i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Pf U,1,7 , 11 of Job Address: 7((5 iiA _ �,, 00 Permit Number: CSI ❑ No one available for inspection: Time (AM/PM Re-Inspection required: Yes (No/ When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE ®tri CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 70 e .t r = lG Permit Number: 2 D ' %"W PL 42 _1 1 -->-> I nc\- te V, oe, i Su5 cn t� c7 S- w)�Q, -,r ❑ No one available for inspection: Time M M Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 __° Date: Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: t i� i f 'z ) P 2 1 Job Address: 76 1 S W. 3 8 T"/' LjL-" tams -3 /b) Permit Number: 7 `/Lf ,-,,,h /ine,f.Z1 r,o✓.rle 'DJ -CV -4P,- /1,14.17-11- <t spi. fe-ac do e((n f ❑ No one available for inspection: Time 1 A /P Re -Inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: 600' DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: _ Job Address: / W 1 `' f ! Permit Number: 2 oP b O / -2 Y y_ ❑ No one available for inspection: Time %- `j ` AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: 4 ' ( ! Inspector: _f. DO NOT REMOVE THIS NOTICE ®` CITY OF WHEAT RIDGE ® Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L JZI I 1 l Job Address: / ` . 7 /o/ Permit Number: / g 1 -i "EJtJ V °.) r4 t`. ❑ No one available for inspection: Time p C-' t AM/T; M/ M ' , Re-Inspection required: Yes No *When corrections have been made, call for re-inspection at 303-234-5933 Date: (-3o-,-7 Inspector: -6,4-ja- DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE j Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office (303) 237-8929 Fax INSPECTION NOTICE Inspection Type t r f F l Job Address: 7 ! Permit Number: 2-o 16 o 1-7 Ir 04-0 4 ress C Ll 4-. tl ❑ No one available for inspection: Time - AN!/2P) Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE 1* 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: i , L CA ?u Job Address: -7� W, 3 v T ei- de Permit Number: 20/6 4 /7q�Z �fn�:t �� 01 P�4rGyA 0,' 9,2 4e �(r' ❑ No one available for inspection: Time �! . �� A �PM Re -Inspection required: Yes,ANo * When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: '4 i C DO NOT REMOVE THIS NOTICE 1A INTERIOR ARCFIITECTS January 3, 2017 ; City of Wheat Ridge Community Development 7500 W. 29th Avenue >w Wheat Ridge, Colorado 80033" Re: Brian Tardif RE: 7615 W Avenue, ,Suite 8101 Wheat Ridge, Co!orado Brian Tardif, The following is our response to the comments below: ATLANTA Architectural: BOSTON CHARLOTTE A. The plans list two suite numbers Suite 13101 and Suite B129. The plans must only show one suite no. The Suite no. that is currently being used by this company will CHICAGO remain the some and the B101 and 8129 will not be used. DALLAS IA: The current tenant suite is B135, the suite number has been revised on all drawing titleblocks and only Suite B135 suite number will be used to DENVER designate the suite. HOUSTON B. Occupant load for the waiting areas was based on 1/30 and we have the LONDON waiting areas 1 /15. This adds 10 to the total occupant load bringing the number from 70 to 80. This does not change the plans other than the occupant loading. LOS ANGELES MIAMI IA: Updated drawings reflect 10 additional occupants, refer to updated Exiting Diagram AN -4.0. NEW YORK C. In the plumbing calculation you show 2 woman's bathrooms and 2 men's ORANGE COUNTY bathrooms and we agree with these calculations, but on the plans you show for 1 PORTLAND woman ,1 man , (unisex are not allowed) and 1 Dr. bathroom. RALEIGH IA: Updated drawing reflect the revise naming of the Unisex restroom and SAN FRANCISCO the Dr. restroom, refer to updated Existing Diagram AN -4.0. SEATTLE Electrical: SILICON VALLEY D. We need Emergency lighting schedule. TORONTO IA: Luminaire schedule on sheet E7.1 lists all luminaires. Fixtures ending in WASHINGTON, DC "E" are emergency lights with the battery backup option. 1750 15TH STREET E. Need Asbestos demolition approval from the state. 3RD FLOOR DENVER, co 80202 g IA: Refer to attached letter of inspection for asbestos containing material 303.672.8500 p 888.990.0489 FAX dated December 28, 2016. www.interiorarchitects.com IA INTERIOR ARCHITECTS GLOBAL ALLIANCE Interior A,chitect, Inc., a Cal;fom6o corporation in AK, AL, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OK, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, VJY /Interior Archlfecrs, P.C., , New York professional services coPorotion In AIL DC, GA, ID, IA, ME, MD, MS, MT, ND, NV, NY, NC, OH, OR, PA / Insedor Architects, P .C. dba Interior Architects, professionol corporc!;on in RI /Inter, or Architects New Jersey PC, a New Jersey professional norp—fl— in NJ and CT / t ferior Architects, P.C. db. IA Ietedor Architects in IL /Wedor Architects, P.C., license #AA26001062 ir, FL / Interior Architects, P.C. db. Inferior Architects, a professionol —p—r — in LA / In±edor ArcnSads, Inc., a Colorado co:pomficn in CO, MI / IA l—,;., A,Aif. is Inc., "Holder of Certificate of P—fi— Archltectaml Instilote of British CoI—bic, Alberta Aso iat— of Architects and Ontario Asoclation of Architect" in British Columbia, Albedo, and Ontaric, C—d. January 3, 2017 1A Page 2of 2 I N T E R 1 0 R ARCHITECTS Plumbing: F. Need expansion tanks on the hot water heaters. IA: Attached sheet P-7.1 shows spec for expansion tank on all water heaters. Electrical: G. Need to identify R-1 E on sheet no. E2.1. IA: Refer to Luminaire Schedule on E-7.1, R-1 E is a 2X2 LED Recessed Troffer with Dimming and Battery Back -Up and the fixtures are tagged in the plans. H. The Interior Lighting Certificate is not signed. IA: See attached signed and stamped copy of sheetE-7.1 with interior comcheck. I. The Branch Panel L2 Load is off please check. It shows that the continuous load at 32642 and the estimated demand load at 32815. IA: The load of 32642 VA is labeled as "Total Conn. Load" no continuous. This load is less than the total estimated demand due to lighting having a demand factor of 125%. J. The plans show the x-ray room is not requiring lead glass. Please check? IA: Refer to sheet A-1.1 Physicist Report provided in the Construction Documents. Sincerely, &�r Emily Sinclair Attachments: AN -4.0 E-7.1 P-7.1 Asbestos Inspection Report_7615 W38th Ave Final Report Interior Ar hltacts, Inc., a Collfornia corp—li— In AK, AL, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OK, SC, SD, TN, TX, UT, VA, VT, VIA, WI, VN, WY / Interior Ar ti9ects, P.C., a New York profe ;,nal s ;ry corporofion in AR, DC, GA, ID, W ME, MD, MS, MT, ND, NV, NY, NC, OH, OR, PA /Interior Archat td , P.C. dbo Interior Archdects, profe iaool cn,poration in RI / Wn iri r Archin d, New Jersey PC, o New Jersey professional corporotioo in NJ and CT / Interior Architects, P.C. &. IA lotarier Architects in IL / Interior Architects, P -C-, ikenae #AA26001062 in FL / lotedor Annhoted , P.C. dbo Interco: Arcbltects, o professional corporation in LAI lntedor Architects, Inc., o Colorado corprnotlon :n CO, MI / IA Inrerl or Arc6lteots I—, "Holder of Cersflmte of Practice, Arahite Enrol Institute of Barish Coiomb=a, Alberto. Asaocio5on of Arcbltects and Ontario Assodonon of Archlfeats" in Bnr,sh Colamblo, Alberta, and Ontario, Conoda Fami wromrrml 3650 Chestnut Place, Denver, Colorado 80216 ( kPhone: 303.296.6022 / Fax: 303.292.1451 December 28, 2016 Grayson Construction, LLC via Email: iustinpuente96 mail.com Justin Puente 3722 Chestnut Place Denver, Colorado 80120 RE: Inspection for Asbestos -Containing Materials 7615 W. 3811 Ave. Wheat Ridge, CO 80033 Family Environmental Project Number: 122116-1 Dear Justin Puente, Family Environmental Compliance Services, Inc. (Family Environmental) is pleased to submit this report summarizing the inspection activities conducted at the building located at 7615 W. 38`h Ave., Wheat Ridge, Colorado 80033 (the Site). Family Environmental was contracted by Justin Puente (the Client) on December 21, 2016 to inspect and identify suspected Asbestos Containing Material (ACM), collect and submit samples for laboratory analysis, and provide an inspection report. Fieldwork was performed on Tuesday December 27, 2016. Data gathered during the visual inspection of the Site, collection of bulk samples of inspected suspect building materials, and the interpretation of analytical results is intended to provide information that meets federal, state, and local regulatory requirements. The sampling and inspection process was conducted in accordance with the following standards: • Asbestos Hazard Emergency Response Act (AHERA) — 40 CFR 763 Subpart E sections 763.80 to 763.99 • Colorado Department of Public Health & Environment (CDPHE) Regulation Number 8 (Reg. 8) • United States Environmental Protection Agency (EPA) National Emissions Standards for Hazardous Air Pollutants (NESHAP) — 40 CFR 61 Part M • Occupational Safety and Health Administration (OSHA) asbestos regulations — 29 CFR 1926 parts 58 and 1101, and 29 CFR 1910 Parts 134 and 1001 1.0 REGULATORY COMPLIANCE This limited inspection was performed in anticipation of demolition activates that are expected to impact suspected asbestos containing building materials. Asbestos has been added to over 3,000 materials and products produced and used in the United States. Suspected ACMs include nearly all building materials with the exception of glass, metal or rubber. According to AHERA and CDPHE Reg. 8, suspect ACMs must be properly sampled and submitted for analysis before any disturbance occurs at the Site. For a building material to be categorized as ACM, it must contain asbestos in a quantity greater than one percent, as confirmed by an EPA accredited National Voluntary Laboratory Accreditation Program (NVLAP) laboratory. ACMs are categorized into two subsequent categories, non -friable asbestos and friable asbestos. Non -friable asbestos is any material that cannot be crumbled, 3650 Chestnut Place, rdMi kWF0MKM1 Phone: 303.296.6022 / Fax: 303.292.1451 Denver, pulverized or reduced to a powder by hand pressure when dry. Friable asbestos can be crumbled, pulverized, or reduced to a powder by hand pressure when dry. ACMs identified in this report are subject to the EPA NESHAP Regulations for Asbestos and the CDPHE Reg. 8. The CDPHE is responsible for the administration of the EPA NESHAP program in Colorado. EPA NESHAP prohibits the release of asbestos fibers into the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated ACMs be identified, classified, quantified and removed where necessary prior disturbance. All friable ACM as well as non -friable ACM that can be rendered friable during demolition or renovation activities must be removed by a licensed General Abatement Contractor (GAC). Materials containing asbestos quantities of one percent (1%) or less are also be subject to OSHA regulations if air concentrations sampled during demolition or renovation activities are at or above the permissible exposure limit (PEL) of 0.10 fibers per cubic centimeter (f/cc) as an eight hour time weighted average, or the excursion limit of 1.0 f/cc as averaged over a 30 minute sampling period. OSHA regulations for General Industry and the Construction Industry include provisions for communication of hazards by the building owner, to building employees, or in the case of subcontracted building services, the subcontractor to subcontractor employees: • The employer must inform maintenance staff and subcontractors if building components have the potential to expose staff and subcontractors to asbestos. • The building owner shall maintain records concerning the presence, location and quantity of ACMs in the building for the duration of ownership, and records shall be transferred to any successive owners. The building owner shall affix labels or signs to positively identified ACMs so that employees and building visitors will be notified of materials that contain asbestos. Such labels or signs shall be placed in areas where employees are likely to impact ACMs as a part of their work. 2.0 SITE / BUILDING INFORMATION The subject building is located at 7615 W. 38`h Ave., Wheat Ridge, Colorado 80033. This was a pre -renovation investigation. Drawings of the existing conditions and renovation designs were provided to Family Environmental prior to the inspection and sampling activities. 3650 Chestnut Place, Denver, Colorado 80216 NF0MrFkd1 Phone: 303.296.6022 / Fax: 303.292.1451 The building is primarily composed of concrete block, steel and drywall construction. The inspected area are detailed in the drawings provided in Appendix B. During the inspection, the inspector was able to identify and inspect: • Twenty -Eight (28) functional spaces were identified. • Twenty -Eight (28) functional spaces were surveyed. 3.0 FIELD ACTIVITIES On Tuesday December 27, 2016, an AHERA/CDPHE accredited asbestos inspector from Family Environmental conducted a limited asbestos inspection of the Site. The purpose of this asbestos inspection was to evaluate for the presence of ACM in the structure. The inspection was conducted in accordance with the methods and procedures outlined in the aforementioned documents. 3.1 Visual Assessment Inspection activities began with visual observation of interior and exterior of the shop to identify homogeneous areas for suspect ACM. Homogenous areas (materials) are classified into one of the following three categories: • Surfacing Material (S) refers to a wide range of trowel or spray -applied materials typically used for acoustical, decorative or fire proofing purposes. • Thermal System Insulation (TSI) refers to insulation that is applied to heating or mechanical system components. Examples include pipe, tank and boiler insulation. • Miscellaneous Materials (M) refers to refers to all other materials that do not fall into one of the previously mentioned categories. Examples include floor tiles, adhesives, composite drywall systems and ceiling tiles. Appendix A provides a summary of the areas determined to be homogeneous and the laboratory results for those areas. 3.2 Physical Assessment and Sample Collection A tactile assessment of each homogeneous area of suspect ACM was conducted to assess the general condition and the friability of the material. Friability was assessed by physically touching suspect materials. Following categorization for material type and friability, a sampling strategy was developed based on the following requirements: Bulk Sampling Strategy titer -in" inn©us Aires ;` Uuiits Surfacing (S) Less than 1,000 1,000 to 5,000 More than 5,000 SF 3 5 7 Thermal System Insulation TSI --- LF/SF/EA 3 Miscellaneous Materials M --- LF/SF/EA Inspectors discretion SF = SQUARE FEET LF = LINEAR FEET EA = EACH M'r Phone: 303.296.6022 /Fax: 303.292.1451 Based on the results of the visual observation, bulk samples of suspect ACM were collected in accordance with AHERA protocols. Random bulk samples of suspect materials were collected in each homogeneous area using wet methods as applicable to reduce the potential for fiber release. During the inspection, Family Environmental staff identified twenty-three (23) suspect homogenous materials, and collected seventy-three (73) bulk samples. The following major categories of homogenous areas were identified as being suspect asbestos containing materials: • Composite Drywall (CDW): One (1) unique CDW was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) CDW identified during this inspection was non -detect for asbestos. • Textured Surfacing (TS): Two (2) unique TS's were identified during this inspection and two (2) were sampled. Laboratory analysis determined that the two (2) TS identified during this inspection were non -detect for asbestos. • Miscellaneous Adhesive (MA): One (1) unique MA was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) MA identified during this inspection was non -detect for asbestos. • Baseboard Adhesive (BBA): One (1) unique BBA was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) BBA identified during this inspection was non -detect for asbestos. • Carpet Adhesive (CA): Two (2) Unique CA's were identified during this inspection and two (2) were sampled. Laboratory analysis determined that the one (1) CA identified during this inspection was non -detect for asbestos • Floor Tile (TS): Seven (7) unique TS's were identified during this inspection and seven (7) were sampled. Laboratory analysis determined that the seven (7) TS's identified during this inspection were non -detect for asbestos. • Sink Undercoating (UC): One (1) unique UC was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) UC identified during this inspection was non -detect for asbestos. • Lav In Ceiling Panel (LIP): Five (5) unique LIP's were identified during this inspection, and five (5) were sampled. Laboratory analysis determined that the five (5) LIP's identified during this inspection was non -detect for asbestos. • Floor Leveling Compound (FLC): One (1) unique FLC was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) FLC identified during this inspection was non -detect for asbestos. Each sample was placed in a sealed container and labeled with a unique sample number using an indelible marker. Appendix C contains the Laboratory Analytical Summary of all of the bulk samples collected. 3.3 Chain of Custody Samples were delivered along with a completed chain -of -custody (COC) to River North Environmental Testing (RNET) Laboratory. Laboratory personnel signed and dated the COC at the time of delivery to acknowledge receipt of the samples. Upon receipt, the laboratory arranged the samples in numerical order to establish any discrepancies between the samples set which was delivered and the COC form. Where (it) discrepancies exist, laboratory personnel noted and initialed the COC and reported the error to the inspector. The laboratory included the signed original copy of the COC with the final analytical report for evidentiary purposes. lami W roff 3650 Chestnut Place, Denver, Colorado 80216 W Phone: 303.296.6022 l Fax: 303.292.1451 4.0 LABORATORY ANALYSIS All bulk samples were relinquished to RNET. All samples were analyzed via Polarized Light Microscope (PLM) in accordance with EPA/600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. RNET is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) under Laboratory Code 200448-0. A copy of the RNET Report of Test Results can be found in Appendix C of this report. 5.0 ASBESTOS CONTAINING MATERIALS The United States EPA and OSHA define an asbestos containing material as a material containing greater than I % asbestos, or a material that is assumed to contain asbestos. Materials that contain asbestos at or below one percent (<1%) are considered to be trace asbestos containing. Current EPA and State of Colorado regulations require the removal of both confirmed, and assumed, FRIABLE ASBESTOS prior to renovation or demolition activities that will impact these materials. The following is a list of friable ACM observed by the inspector: No friable asbestos was observed during this inspection. Depending on the renovation or demolition techniques used, the current EPA and State of Colorado regulations may require the removal of both confirmed, and assumed, NON -FRIABLE ASBESTOS prior to any activities that may impact these materials. The following is a list of non - friable ACM observed at the site: No non -friable asbestos was observed during this inspection. Prior to any disturbance, the following ASSUMED ASBESTOS (ACM) should be sampled by a certified asbestos building inspector to determine the actual asbestos content, or be treated as asbestos containing: No materials were assumed during this inspection. Current EPA and State of Colorado regulations do not require the removal of materials found to contain TRACE ASBESTOS (<I%) prior to initiating renovation or demolition activities that will impact this material. The following materials contain trace amounts of asbestos: No trace (<1 %) asbestos was observed during this inspection. 6.0 CONCLUSIONS & RECOMMENDATIONS Based on our observations and the analytical results, no friable or non -friable asbestos is present in the area of the inspection. All non -friable or friable materials must be removed by a certified abatement contractor prior to renovation or demolition. If trace (<I%) asbestos materials exist on the site, and they are not removed, the renovation or demolition contractor must be notified of the presence of this material prior to disturbance and comply with all current OSHA regulations for employee exposure to asbestos. Additionally, the renovation or demolition contractor must comply with applicable NESHAP asbestos emission control regulations for structures containing trace amounts of asbestos. These materials may not be subject to sanding, grinding or cutting during renovation or demolition activities. 3650 Chestnut Place, Denver, Colorado 80216 Phone: 303.296.6022 / Fax: 303.292. 1451 If during demolition/renovation activities, materials are encountered which have not been discussed in this report; stop all activities in the immediate area, and contact a certified asbestos building inspector to sample the suspect material. Family Environmental is available to perform further sampling at your request. 7.0 LIMITATIONS This asbestos inspection was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and/or recommendations expressed in this report are based on conditions observed during our limited inspection, and the analytical results of the samples collected. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This limited asbestos inspection report is not considered a comprehensive inspection report and it must be understood that the existence of unique or concealed asbestos may be possible. This report has been prepared on behalf of, and exclusively for use by the client for specific application to the project indicated. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Family Environmental does not warrant the work of regulatory agencies or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made. This report is not to be used as a bidding document. Should you have any questions or require additional information or services, please feel free to contact Family Environmental at (303) 296-6022. Sincerely, Family Environmental Compliance Services, Inc. Digitally signed by Josh Sieger ON: cn=Josh Sieger, 0,0 , Josh Sieger email=jsieger@familyenvironmen tal.com, c=US Date: 2016.12.29 13:53:48 -07'00' Josh Sieger, Environmental Scientist AHERA/CDPHE Accredited Asbestos Building Inspector (CABI), Air Monitoring Specialist (AMS), Project Designer (PD) 10744 Attachments: Appendix A: Homogenous Materials Table Appendix B: Sample Location Drawings Appendix C: Laboratory Analytical Report Appendix D: Inspector Certifications Jerome B. Hairston, CIEC Industrial Hygiene Program Manager AHERA/CDPHE Accredited Asbestos Building Inspector (CABI), Air Monitoring Specialist (AMS), Project Designer (PD) #3799 Alp 3650 Chestnut Place, Denver, Colorado 80216 Phone: 303.296.6022 / Fax: 303.292.1451 HOMOGENOUS MATERIALS TABLE wromfuml 3650 Chestnut Place, Denver, Colorado 80216 Phone: 303.296.6022 / Fax: 303.292.1451 SF = SQUARE FEET LF = LINEAR FEET EA = EACH ND = NON DETECT FOR ASBESTOS Des,-, OEM As eslt BBA -01 Cream Baseboard Adhesive M NFII --- ND CA -01 Tan Carpet Adhesive M NFII --- ND --- CA-02 Remnant Carpet Adhesive M NFII --- ND FTC -01 Purple Floor Tile M NFI --- ND --- FTC-02 Orange Floor Tile M NFI --- ND --- FTC-03 Tan Floor Tile M NFI --- ND --- FTC-04 Blue Gray Mottled 12x12 Floor NFI Tile M --- ND --- FTC -05 Gray Mottled 12x12 Floor Tile M NFl --- ND --- FTC-06 Green 12x12 Floor Tile M NFI ND --- Gray, Black, and White Speckled NFI FTC-07 12x12 Floor Tile M --- ND --- CDW-01 White Drywall and Mud M NFII --- ND --- White 2x4 with Large Fissures F LIP-01 and Pinholes M --- ND --- LIP -02 White 20 Lay in Panel with M F --- ND --- Large Craters and Small Pinholes LIP -03 White 2x4 Lay in Panel with F Small Craters and Pinholes M --- ND --- LIP -04 20 Vinyl Faced Lay in Panel M F ND --- White 2x4 Lay in Panel with F LIP-05 Small Fissure and Pinholes M ND --- MA -01 Brown Counter Adhesive M NFII ND --- TS-01 Heavy Orange Peel S F ND --- TS-02 Light Orange Peel S F ND --- UC-01 Black Sink Undercoating M NFII --- ND --- SVF-01 Green Faux Tile Patterned Sheet M NFII ND --- Vinyl Flooring Light Green Marble Patterned NFII SVF-02 Sealed Sheet Vinyl Flooring M ND --- FLC-01 White Floor Leveling Compound S NFII ND SF = SQUARE FEET LF = LINEAR FEET EA = EACH ND = NON DETECT FOR ASBESTOS 3650 Chestnut Place, Denver, Colorado 80216 Jim imfowumi Phone: 303.296.6022 / Fax: 303.292.1451 APPENDIX B SAMPLE LOCATION DRAWINGS L -C7 If, J�p ----J d x l l ii M ------- 41 -------- ---E)V`G— VIG Ev G �A- IF fp) --------- - ---------- a4 CO. . . . . ..... . ............. .... raml wrORTKp(dj 3650 Chestnut Place, Denver, Colorado 80216 Phone: 303.296.6022 / Fax: 303.292.1451 APPENDIX C MA UVjVMW%WA'jL• *AWTRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0073 4Denver, CO 80216 Fax: 303-292-1451 12/28/2016 Family Environmental Services 365UChestnut Place Denver, Colorado 8O216 Re: 7615VV.38thAve. RM15-50 Mc Hairston, Attached are the results of Polarized Light Microscopic (PLM) analysis for asbestos contained in the bulk sample materials submitted tnthis facility un 12/28/2016 Bulk samples are analyzed in accordance with USEPA test method EPA/600/M4-82-020 and EP/V600/R- 93/116, which requires that distinctly different materials orlayers present within a sample be analyzed and reported separately. (For measurement uncertainty, refer to table 2.1 in EP/V600/R-93/116 method.) Sometimes it is not possible to completely separate thin or strongly adhering layers, such as paint or adhesive, and a combined result is given. For some complex materials, such as drywa||/tape/mudjo|nts, a composite or overall asbestos content may be reported in addition to individual layer results. RNET, Inc. is currently accredited for bulk asbestos analysis by the National Voluntary Laboratory Accreditation Program (NVLAP) of the National Institute of Standards and Technology (NIST). Our NVLAP laboratory code number is 200448-0. Due tothe limitations ufthe EPA 6OO Method, nonfhab}eorganically bound materials (NO8s)such asfloor tiles can be difficult to analyze via PLM. EPA recommends that all 0OBs reported as non -detect by PLM analysis be further analyzed by Transmission Electron Microscopy for more definitive nssu|ts. Please note that the PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. The analytical results provided in this report apply only bothe samples submitted to the laboratory. This report is confidential. Details of this report will not be discussed with any person or agency not associated with you or your organization. This report must be reproduced in its entirety and shall not be copied in part or used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. Samples will be held fora minimum of sixty days unless longer storage is requested. If you have any questions regarding the content of this report please call RNET, Inc. at 303'296-6022. ' Marissa Urdiales Asbestos Analyst murdia|es@familyenvimnmentaicom NVLAP tab Code 200448,0 River North Environmental Testing, Inc. J850Chestnut Place 303-297-0079 kw4T Denver,CO 80D1G Fox: 303�02 1451 wewmetesting.cmm inAu@meteobng,cum REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAPLab Code 2OO44B-8 CLIENT: Family Environmental Compliance Services PROJECT: PLK810-570 Lab-|DNm. Layer No. Asbestos Non-Asbestos Sample ID Description Leyer% Type M Components M PLk416-570-01 7615-1O0-BBAO1'1Adhesive, Tan, Homogeneous, LAYER None Detected Resinous 100% Other Non-Fibrous 100% PLM16-570-02 7615-105-BBA01-2 7D15-105-BBAD1-2Adhen|ve.Tan, Hnmugenenue, LAYER None Detected Resinous 100% Other Non-Fibrous 100% 7O15-1O4'BBAU1-3Adhesive, Tan, Homngeneoun, LAYER None Detected Resinous 100% Other Non-Fibrous 100% _ PLK410'570-04 7O15'119-BB/O1-4Adhesive, Tan, Homogeneous, LAYER None Detected Resinous 100% Omo,Nnn'numua 100% ___ PLh\10-5r0-V5 7O15-127-8BA01-5Adhesive with Debris, Tan, Brown, and LaYE*1 None Detected Cellulose Fiber 45% Gray. Homogeneous, 100% 0mo,wnn'pihmvs 00% Resinous/Fibrous mntenm PLNY18~570-06 7015-100-C/01-1 Adhesive, Yellow, Non' LAYER None Detected Synthetic Fiber s% homogeneoun. Resinous 100% Other Non-Fibrous nsm PLkA16-570-07 7015-119-CAO1-2 Adhesive, Yellow, Non' uo'sR 1 None Detected Synthetic Fiber m% homoganenuo. Resinous 100% Other Non-Fibrous we% PLM16-570-08 7615-121-CAO1'3 Adhesive, Yellow, Non- LAYER None Detected Synthetic Fiber a% hnmogeneouo. Hos|nnuu 100m Oma,won'Fibmvs us% PLyW18'570'09 - ------------- 7015'122'CA02'1 Adhesive, Yellow, Non- LAYER wn"e Detected Synthetic Fiber s% homogenmouo. Resinous 100% Other Non-Fibrous 9e% PLK816-570-16 �����------------�� 7615-123-CA02-2 LAYER LAYER None Detected Adhesive, Yellow, Homogeneous, *u% ome,wvn'riumvs 100% Resinous Material LAYER LAYER None Detected Adhesive, Green, HomoQaneoua, On% Ome,won'Fixmua 100m Resinous Material kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www-metesting.com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services None Detected Cellulose Fiber 15% PROJECT: PLM16-570 Other Non -Fibrous 85% Lab -ID No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type {°/®) Components M PLM16-570-11 5% Other Non -Fibrous 100% 7615-124-CA02-3 Adhesive, Yellow, Homogeneous, LAYER 1 None Detected Material LAYER 3 Resinous 100% None Detected Other Non -Fibrous 100% PLM16-570-12 5% Other Non -Fibrous 100% 7615-100-CDW0I- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15% Drywall, Brown, Homogeneous, Fine 85% Other Non -Fibrous 85% Grained/Fibrous LAYER 1 Material Cellulose Fiber 15% LAYER 2 LAYER 2 None Detected Other Non -Fibrous 85% Mud with Paint, White, 15% Other Non -Fibrous 100% Homogeneous, Fine Grained LAYER 2 Material PLM16-570-13 7615-105-CDW01- LAYER I LAYER I None Detected Cellulose Fiber 15% 2 Drywall, White and Brown, 90% Other Non -Fibrous 85% Homogeneous, Fine Grained/Fibrous Material LAYER 2 LAYER 2 None Detected Mud with Paint, White, Non- 5% Other Non -Fibrous 100% homogeneous, Fine Grained Material LAYER 3 LAYER 3 None Detected Mud with Paint, White and Off White, 5% Other Non -Fibrous 100% Non-homogeneous, Fine Grained Material PLM16-570-14 7615-119-CDW01- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15% 3 Drywall, White and Brown, 90% Other Non -Fibrous 85% Homogeneous, Fine Grained/Fibrous Material LAYER 2 LAYER 2 None Detected Mud with Paint, White, Non- 5% Other Non -Fibrous 100% homogeneous, Fine Grained Material LAYER 3 LAYER 3 None Detected Mud with Paint, White and Off White, 5% Other Non -Fibrous 100% Non-homogeneous, Fine Grained Material � CLIENT: PROJECT: Lab -ID No. Sample ID River North Environmental Testing, Inc. 3650 Chestnut Place 803-297-0079 Denver, 0J0Q216 Fax: 3O3-292- 451 MWT4 mww.meteu@in0.onm inhm@meteadng.xom REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAPLab Code 2OO448-O Family Environmental Compliance Services PLK416-67O DescriptionLayer % Type Layer No. Asbestos PLM16-570-5 LAYER 7O15-120-CDVVO1-LAYER 1 LAYER 4 Drywall, White and Brown, rs% Homogeneous, FineGminmd/Fibmuu LAYER LAYER uv/enu Mud, White, Homoganaouo. Fina 10% Grained LAYER LAYER LAYER Tape, White, Hnmngmnanus, Fibrous 10% LAYER LAYER Mud with Paint, White and Off White, n& Homogoneouo. Fine Grained 7815'11O-CDYVO1'LAYER 1 LAYER 5 Drywall, White and Brown, 75% Homugenaovy, FineGna|negK=bomo 15m LAYER LAYER Mud, White, Hnmogmneouo, Fine 10% Grained 100% LAYER 3 LAYER Tape, White, Homoganeoua, Fibrous 10% LAYER LAYER Mud with Paint, White and Blue, s% Homngeneoua. Fine Grained 7O15~1O6-CDVVO1'LAYER 1 LAYER 0 Drywall, White and Brown, om% Homogeneous, FinaGnmined/Fihnous 15m LAYER LAYER Mud with Paint, White and Blue, 15% Homogeneoum, Fine Grained 100% 7615422-C%JVVO1'LAYER 1 LAYER 7 Drywall, White and Brown, ao% Homogeneous, Fine Grained/Fibrous LAYER LAYER Mud with Paint, White and Gray, 15% Homogeneous, Fine Grained None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected zm�� None Detected None Detected Non -Asbestos 100% y&) Components %Q Cellulose Fiber 15m Other Non -Fibrous 85m matmmn| 100% Other Non -Fibrous 100% Material Cellulose Fiber 00% Ommwvn'Fmmve 1% Other Non -Fibrous 100% Material Cellulose Fiber 15& Other Non -Fibrous e5% memma| Other wnn-Fmmva 100% Material oymmue Fiber 00% ome,mvn'numus 1% Other Non -Fibrous 100% womaoo| Cellulose Fiber Other Non -Fibrous Material Cellulose Fiber Oms,won'piumvu Material Cellulose Fiber Other Non -Fibrous Material Cellulose Fiber omerwon'r/umvm Material Page 3 of 13 River North Environment2d Testing, Inc. 365OChestnut Place 383-297-0078 kw4T Denver,CO 00218 Fnx: 303-292-1451 vmmw,me1emiin0.nom info@ynm1msdog.cum REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAPLab Code 2O0440 -O CLIENT: Family Environmental Compliance Services PROJECT: PLKX18-570 Lab -ID No. Layer No. Asbestos Non -Asbestos Sample ID Descripfion Layer% Type nQ Components PLM10'570-18 7O15-127-CDVVO1- LAYER i LAYER None Detected Cellulose Fiber 15w O Drywall, White and Brown, ao% Other Non -Fibrous uo% Homngeneauo. FineQnoinud/Rbmuo mamna| LAYER LAYER None Detected Cellulose Fiber 15% Mud with Paint, White and Gray, 15% Vmo,wnn'F/umus us% Momugeneouo. Fine Grained meoa,ia/ PLM10'570-20 7015-123'CDVV01- LAYER 1 LAYER None Detected Cellulose Fiber 15% S Drywall, White and Brown, am% Other Non -Fibrous on% Homogeneoua. FinaGnainad/F|hmua Material LAYER LAYER None Detected Cellulose Fiber 15% Mud with Paint, White and Gray, 15% Ome,mnn'nmnuo os% Humogeneoue. Fine Grained wmvena| PLM16-570-21 7615'122-FLCO1-1 Compound and Adhesive, White and LAYER None Detected YaUow. Non-homogoneouo, 100% Other Non -Fibrous 100% Rasinnus/FineGmioed mutemm 7O15'120-FLCO1-2LAYER 1 LAYER None Detected Compound, White, Non oum Other Non -Fibrous 100% homogeneous, Fine Grained weteoe| LAYER LAYER None Detected Compound with Adhesive, Gray and 00% {xoormvn'F|unous 100% YeUmw, Non-homogeneous, Fine Material Grained/Resinous PLM16-570-23 7015-127'FLCO1'3LAYER 1 LAYER None Detected Compound, White, Non- 50% omerwomfiumus 100% homogeneous, Fine Grained Material LAYER LAYER None Detected Compound with Adhesive, Gray and oom Om=rwvn'Fmovvs 100% Yexm*. Non-homogeneous, Fine mutwma| Grained/Resinous ppyr 4 of 13 River North Environmental Testing, Inc. JV5OChestnut Place 303-297-0078 kw4T Denver,CO MU31G Fax: 303-292-1451 www.metwmting.com infa@metendngcam REPORT OF TEST RESULTS PLIM Bulk Asbestos Analysis NVLAPLab Code 20O448 -O CLIENT Family Environmental Compliance Services Compound with Adhesive, Yellow and PROJECT: PLM 16-570 VVhde, Non-homogeneous, Fine Material Lab -ID No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer% Type M Components PLM10-570-24 Material 7015-1OO'FTC01'1 LAYER 1 LAYER None Detected Compound, Off White, 45% Other Non -Fibrous Hnmogenoouo, Fine Grained Wm$ma| LAYER LAYER None Detected Cellulose Fiber Adhesive, Yellow and Black, Non' o% Other Non -Fibrous homogeneous, Resinous Material LAYER8 LAYER None Detected Floor Tile, Red, Hnmogenenum, Hard 45% Other Non -Fibrous LAYER LAYER None Detected Adhesive, Yellow, Homogeneous, o% Other Non -Fibrous Resinous Material PLM16-570-25 7D15-1UO'FTC0-1LAYER 1 LAYER None Detected Oompound. Off White, 45Y6 Ome,wnn'Fiumus Homogeneous, Fine Grained Material LAYER LAYER None Detected Cellulose Fiber Adhesive, Yellow and Black, Non' 5% Otxo,won'Fibmvs homogeneous, Resinous Material LAYER LAYER None Detected Floor Tile, Orange, Homognneouo, 45% OmerNvn'Fiumus Hand Material LAYER LAYER None Detected Adhesive, Yellow, Homogeneous, nm Otxe,Non'Fiunmn Resinous Material PL/N10-570'28 7615-104-FTC03-1 LAYER LAYER None Detected Floor Tile, Tan, Homogeneous, Hand on% Other Non -Fibrous LAYER LAYER None Detected Adhesive, Clear, Homogeneous, u% Other Non -Fibrous Resinous womxa/ LAYER LAYER None Detected Cellulose Fiber Fibrous Material, Off White, 18% omerwon'Fiumum Homngeneouo. Fibrous waueon| PLM16-570-27 7015-11Uf7CO41LAYER 1 LAYER 1 None Detected Compound with Adhesive, Yellow and uQ% Omewvvfiomvo VVhde, Non-homogeneous, Fine Material Grained/Resinous LAYER LAYER None Detected Floor Tile, Gray and Blue, 00% Dtxerwnn'Fiunmvx Homugenmuuo, Hand Material am kwT4River North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www.metesting,corn info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type M Components PLM16-570-28 7615-111 -FTC04-2 LAYER 1 LAYER 1 None Detected Adhesive, Yellow, Homogeneous, 2% Other Non -Fibrous Resinous Material LAYER 2 LAYER 2 None Detected Floor Tile, Gray and Blue, 98% Other Non -Fibrous Homogeneous, Hard Material PLM 16-570-29 7615-114-FTC04-3 LAYER 1 LAYER 1 Adhesive, Yellow, Homogeneous, 2% Resinous LAYER 2 LAYER 2 Floor Tile, Gray and Blue, 98% Homogeneous, Hard PLM 16-570-30 7615-118-FTC05-1 LAYER I LAYER 1 Compound and Adhesive, White and 5% Yellow, Non-homogeneous, Fine Grained/Resinous LAYER 2 LAYER 2 Floor Tile, Green, Homogeneous, 95% Hard PLM 16-570-31 7615-121-FTC06-1 LAYER I LAYER 1 Compound and Adhesive, White and 5% Yellow, Non-homogeneous, Fine Grained/Resinous LAYER 2 LAYER 2 Floor Tile, Green, Homogeneous, 95% Hard PLM16-570-32 7615-125-FTC07-1 LAYER 1 LAYER 1 Adhesive, Yellow, Homogeneous, 2% Resinous LAYER 2 LAYER 2 Floor Tile, Gray and Black, 98% Homogeneous, Hard None Detected None Detected None Detected None Detected None Detected None Detected Other Non -Fibrous Material Other Non -Fibrous Material Other Non -Fibrous Material Other Non -Fibrous Material Other Non -Fibrous Material Other Non -Fibrous Material M 100% 100% 100% 100% 100% 100% 100% 100% None Detected Other Non -Fibrous 100% Material None Detected Other Non -Fibrous 100% Material Page 6 of 13 kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www.metesting.com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type (0/0) Components PLM 16-570-33 7615-126-FTC07-2 LAYER 1 LAYER I None Detected Adhesive, Yellow, Homogeneous, 2% Other Non -Fibrous 100% Resinous Material LAYER 2 LAYER 2 None Detected Floor Tile, Gray and Black, 98% Other Non -Fibrous 100% Homogeneous, Hard Material PLM16-570-34 7615-127-FTC07-3 LAYER 1 LAYER I None Detected Adhesive, Yellow, Homogeneous, 2% Other Non -Fibrous 100% Resinous Material LAYER 2 LAYER 2 None Detected Floor Tile, Gray and Black, 98% Other Non -Fibrous 100% Homogeneous, Hard Material PLM16-570-35 7615-100-LIP0I-1 Ceiling Tile, Brown and White, LAYER 1 None Detected Cellulose Fiber 40% Homogeneous, Fibrous 100% Fibrous Glass 20% Other Non -Fibrous 40% Material PLM 16-570-36 7615-119-LIP01-2 Ceiling Tile, Brown and White, LAYER I None Detected Cellulose Fiber 40% Homogeneous, Fibrous 100% Fibrous Glass 20% Other Non -Fibrous 40% Material PLM 16-570-37 7615-121-LIP01-3 Ceiling Tile, Brown and White, LAYER 1 None Detected Cellulose Fiber 40% Homogeneous, Fibrous 100% Fibrous Glass 20% Other Non -Fibrous 40% Material PLM16-570-38 7615-104-LIP02-1 Ceiling Tile, Brown and White, LAYER I None Detected Fibrous Glass 30% Homogeneous, Fibrous 100% Cellulose Fiber 40% Other Non -Fibrous 30% Material PLM16-570-39 7615-119-LIP02-2 Ceiling Tile, Brown and White, LAYER 1 None Detected Fibrous Glass 30% Homogeneous, Fibrous 100% Cellulose Fiber 40% Other Non -Fibrous 30% Material kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www.metesting.com info@metesting com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. Layer No, Asbestos Non -Asbestos Sample ID Description Layer % Type Components PLM 16-570-40 7615-121 -LIP02-3 Ceiling Tile, Brown and White, LAYER 1 None Detected Fibrous Glass Homogeneous, Fibrous 100% Cellulose Fiber Other Non -Fibrous Material PLM 16-570-41 30% 40% 30% 7615-119-LIP03-1 Ceiling Tile, Brown and White, LAYER 1 None Detected Fibrous Glass 30% Homogeneous, Fibrous 100% Cellulose Fiber 40% 100% Other Non -Fibrous 30% Material PLM16-570-42 30% 7615-121-LIP03-2 Ceiling Tile, Brown and White, LAYER 1 None Detected Fibrous Glass 30% Homogeneous, Fibrous 100% Cellulose Fiber 40% Other Non -Fibrous 30% LAYER 1 None Detected Material 10% PLM 16-570-43 7615-121-LIP03-3 Ceiling Tile, Brown and White, LAYER 1 None Detected Fibrous Glass 30% Homogeneous, Fibrous 100% Cellulose Fiber 40% Other Non -Fibrous 30% Material PLM 16-570-44 7615-106-LIP04-1 Lay -in Ceiling Panel, Off White, Brown, LAYER 1 None Detected Cellulose Fiber 10% and White, Homogeneous, Fine 100% Fibrous Glass 2% Grained/Fibrous Other Non -Fibrous 88% PLM 16-570-45 7615-106-LIP04-2 Lay -in Ceiling Panel, Off White, Brown, LAYER 1 None Detected Cellulose Fiber 10% and White, Homogeneous, Fine 100% Fibrous Glass 2% Grained/Fibrous Other Non -Fibrous 88% PLM16-570-46 7615-106-LIP04-3 Lay -in Ceiling Panel, Off White, Brown, LAYER 1 None Detected Cellulose Fiber 10% and White, Homogeneous, Fine 100% Fibrous Glass 2% Grained/Fibrous Other Non -Fibrous 88% PLM 16-570-47 7615-122-LIP05-1 Ceiling Tile, Brown and White, LAYER 1 None Detected Cellulose Fiber 40% Homogeneous, Fibrous 100% Fibrous Glass 30% Other Non -Fibrous 30% Material Page 8 of 13 kwT4River North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO, 80216 Fax: 303-292-1451 www,metesting.com info@metesting,com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab-ID No. Layer No. Asbestos Non-Asbestos Sample ID Description Layer % Type M Components M PLM 16-570-48 7615-127-LIP05-2 Ceiling Tile, Brown and White, LAYER I None Detected Cellulose Fiber 40% Homogeneous, Fibrous 100% Fibrous Glass 30% Other Non-Fibrous 30% Material PLM16-570-49 7615-123-LIP05-3 Ceiling Tile, Brown and White, LAYER 1 None Detected Cellulose Fiber 40% Homogeneous, Fibrous 100% Fibrous Glass 30% Other Non-Fibrous 30% Material PLM1 6-570-50 7615-122-MAOI-I Mastic, Brown, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non-Fibrous 100%® PLM 16-570-51 7615-105-SVF0I-1 LAYER I LAYER 1 None Detected Adhesive, Black and Yellow, Non- 10% Other Non-Fibrous 100% homogeneous, Resinous Material LAYER 2 LAYER 2 None Detected Cellulose Fiber 35% Sheet Flooring, Off White and Gray, 90% Fibrous Glass 5% Homogeneous, Semi-Fibrous Other Non-Fibrous 60% PLM 16-570-52 7615-104-SVF0I-2 Sheet Flooring, Off White and Gray, LAYER I None Detected Cellulose Fiber 35% Homogeneous, Semi -Fibrous 100% Fibrous Glass 5% Resinous Other Non -Fibrous 60% LAYER 2 LAYER 2 None Detected Material 35% PLM 16-570-53 90% Fibrous Glass 5% 7615-115-SVF01-3 LAYER 1 LAYER 1 None Detected Other Non -Fibrous 60% Adhesive, Yellow, Homogeneous, 10% Other Non -Fibrous 100% Resinous Material LAYER 2 LAYER 2 None Detected Cellulose Fiber 35%® Sheet Flooring, Off White and Gray, 90% Fibrous Glass 5% Homogeneous, Semi -Fibrous Other Non -Fibrous 60% ZxxERNE=#' 7615-117-SVF01-4 LAYER I LAYER I None Detected Adhesive, Yellow, Homogeneous, 10% Other Non -Fibrous 100% Resinous Material LAYER 2 LAYER 2 None Detected Cellulose Fiber 35% Sheet Flooring, Off White and Gray, 90% Fibrous Glass 5% Homogeneous, Semi -Fibrous Other Non -Fibrous 60% kw4TVdver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www.metesting.com info@metesting,com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services None Detected Cellulose Fiber 90% PROJECT: PLM16-570 15% Fibrous Glass 5% Lab-lD No. homogeneous, Fibrous Layer No. Asbestos Non -Asbestos 5% Sample ID Description Layer % Type Components M PLM16-570-55 Floor Tile, White, Homogeneous, 20% Other Non -Fibrous 100% 7615-120-SVF02-1 LAYER 1 LAYER 1 None Detected Material Floor Tile, Off White, Homogeneous, 75% LAYER 3 Other Non -Fibrous 100% Hard Adhesive, Yellow, Homogeneous, 10% Material Other Non -Fibrous 100% LAYER 2 LAYER 2 None Detected Material Sheet Flooring, White and Green, 10% LAYER 4 Other Non -Fibrous 100% Non-homogeneous, Resinous Sheet Flooring, Off White and Blue, 55% Material Other Non -Fibrous 100% LAYER 3 LAYER 3 None Detected Material Adhesive, Brown and Yellow, Non- 5% Other Non -Fibrous 100% homogeneous, Resinous LAYER I LAYER 1 Material Cellulose Fiber 20% LAYER 4 LAYER 4 None Detected Other Non -Fibrous 80% Sheet Flooring, Off White and Blue, 10% Other Non -Fibrous 100% Non-homogeneous, Resinous LAYER 2 LAYER 2 Material PLM 16-570-56 7615-106-SVF02-2 LAYER I LAYER 1 None Detected Cellulose Fiber 90% Fibrous Backing, Off White, Non- 15% Fibrous Glass 5% homogeneous, Fibrous Other Non -Fibrous 5% LAYER 2 LAYER 2 None Detected Floor Tile, White, Homogeneous, 20% Other Non -Fibrous 100% Hard Material LAYER 3 LAYER 3 None Detected Adhesive, Yellow, Homogeneous, 10% Other Non -Fibrous 100% Resinous Material LAYER 4 LAYER 4 None Detected Sheet Flooring, Off White and Blue, 55% Other Non -Fibrous 100% Homogeneous, Resinous Material PLM 16-570-57 7615-100-TS01-1 LAYER I LAYER 1 None Detected Cellulose Fiber 20% Drywall, White and Brown, 80%® Other Non -Fibrous 80% Homogeneous, Fine Grained/Fibrous Material LAYER 2 LAYER 2 None Detected Mud with Paint, White and Tan, 20% Other Non -Fibrous 100% Homogeneous, Fine Grained Material PLM16-570-58 - - - ---- ---- 7615-105-TS01-2 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20% Drywall, White and Brown, 80% Other Non -Fibrous 80% Homogeneous, Fine Grained/Fibrous Material LAYER 2 LAYER 2 None Detected Mud with Paint, White and Tan, 20% Other Non -Fibrous 100% Homogeneous, Fine Grained Material Page 10 of 13 River North Environmental Testing, Inc. 3G50Chestnut Place 303-297-0079 Denver, C08O21G Fax: 303-292-1451 kwT4 nmw.metmsting.comm inhs@metosting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAPLab Code 2OO448'0 CLIENT: Family Environmental Compliance Services LAYER None Detected Cellulose Fiber 20% PROJECT: PLM18-570 80% Other Non -Fibrous 80% Lab -ID No. Layer No. Asbestos Non -Asbestos LAYER Sample ID Deacdptlon Layer% Type M Components y� PL[N18-570'59 100% Homogeneous, Fine Grained Material 7616404-TS01'3 LAYER1 LAYER None Detected Cellulose Fiber ao% 7615'119-TS02-1 Dryva||. White and 8mvmn. on% Cellulose Fiber Other Non -Fibrous ou% Off White, Momngen000s, Fine Homogeneous, FineGroinmd/Fibmus Omo,wnn'p|bmvs oum Material Grained/Fibrous LAYER LAYER None Detected Mud with Paint, White and Blue, co% mmo,wnvf|bnnvs 100% Homogeneous, Fine Grained Material PL/N16'570-60 7615-103-TS01'4 L/0ER1 LAYER None Detected Cellulose Fiber on& Drywall, White and Brown, uo% Other Non -Fibrous un% Hmmngeneous. FinaGmined/Fibmus mavenm LAYER LAYER None Detected Mud with Paint, White and Off White, xV% mherwon'F|bmvo 100% Homogeneous, Fine Grained mo*wn*| PLKV16-570- 1 7615-103-TG01-5 LAYER1 LAYER None Detected Cellulose Fiber on% Drywall, White and Brown, on% Other Non -Fibrous nu% Homugeneouu. FineGroined/Fibmua Material LAYER LAYER None Detected Mud with Paint, White and Brown, uo% Other Non -Fibrous 100% Homogeneous, Fine Grained mauna| PLM16-570-62 7615-122-TG01-6 LAYER LAYER None Detected Cellulose Fiber co% Drywall, White and Brown, no% Other Non -Fibrous ou% Homogeneous, FinoGrained/Fibmuy Material LAYER LAYER None Detected Mud with Paint, White, oom Dmerwnn'piumou 100% Homogeneous, Fine Grained Material PLM18-570-63 7615-127-TS01-7 LAYER LAYER None Detected Cellulose Fiber 20% Drywall, White and Brown, 80% Other Non -Fibrous 80% Homogeneous, FineQminedFibmun Material LAYER LAYER None Detected Mud with Paint, White, 20% Other Non -Fibrous 100% Homogeneous, Fine Grained Material PLk416-570-64 7615'119-TS02-1 Drywall with Paint, White, Brown, and LAYER None Detected Cellulose Fiber on% Off White, Momngen000s, Fine 100% Omo,wnn'p|bmvs oum Grained/Fibrous Material kw4TRiver North Environmental Testing, Inc. 365 D 0 Chestnut O 80Place 30 03-297-0075 enver, C216 Fax: 33-292-1451 www.metesting,com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: ami y nvironmental Compliance Services PROJECT: PLM16-570 Lab -11) No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type M Components PLM16-570-65 7615-120-TS02-2 Drywall with Paint, White, Brown, and LAYER 1 None Detected Cellulose Fiber 20% Off White, Homogeneous, Fine 100% Other Non -Fibrous 80% Grained/Fibrous Material PLM16-570-66 7615-116-TS02-3 Drywall with Paint, White, Brown, and LAYER None Detected Cellulose Fiber 20% Blue, Homogeneous, Fine 100% Other Non -Fibrous 80% Grained/Fibrous Material PLM16-570-67 7615-106-TS02-4 Drywall with Paint, White, Brown, and LAYER None Detected Cellulose Fiber 20% Blue, Homogeneous, Fine 100% Other Non -Fibrous 80% Grained/Fibrous Material PLM16-570-68 7615-123-TS02-5 Drywall with Paint, White, Brown, and LAYER 1 None Detected Cellulose Fiber 20% Gray, Homogeneous, Fine 100% Other Non -Fibrous 80% Grained/Fibrous Material PLM16-570-69 7615-124-TS02-6 Drywall with Paint, White, Brown, and LAYER I None Detected Cellulose Fiber 20% Green, Homogeneous, Fine 100% Other Non -Fibrous 80% Grained/Fibrous Material PLM16-570-70 7615-125-TS02-7 Drywall with Paint, White, Brown, and LAYER 1 None Detected Cellulose Fiber 20% Green, Homogeneous, Fine 100% Other Non -Fibrous 80% Grained/Fibrous Material PLM 16-570-71 7615-106-UC01-1 Undercoating, Black, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non -Fibrous 100% PLM 16-570-72 7615-121-UC01-2 Undercoating, Black, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non -Fibrous 100% PLM16-570-73 7615-121-UC01-3 Undercoating, Black, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non -Fibrous 100% Page 12 of 13 kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www.metesting.com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type M Components M ADDITIONAL COMMENTS: All separable parts or layers (except paint) within the same sample are analyzed and reported individually. Composite asbestos percent is reported, if applicable, by visual estimation. ND = None Detected TR = Trace, less than 1.0% Analyst: Date: 12/28/2016 Mais4urcTial-es Page 13 of 13 Document No: FCF-04.00 Jkw"Agw" Client: Family Environmental Compliance Services Address: 3650 Chestnut Place I WROMY-ToW Jk i' Place * Denver, CO 80216 Ph: 303-297-0079 * Fax: 303-292-1451 com foC "�r sti g.com www,rnetesting.com info@rnetesting.co Fax #/Email: )super @f am flyerlyi ro n menta 1. com, Date Sampled: 12/27/2016 Sample Location: 7615 W 38th ave, Special Instructions: Lab ID (for lab use only) Client ID Description Type of Analysis Volume/Other 7615400-BBA01-1 PLM 7615 11 5 8 B Abd 2 ................. PLM 7615404-BBA01-3 PLM �15 -119-BBA01-4..... ....... PLMq .................. ............ ... . .......... ...... ............. ................. . ...... 7615 PLM 7615-100-CA01-1 PLM ........... 7615-119- Ol-2 PLM 7615-121 01-3 ... ........ PLM _L)cj 7615-122- 02-1 PLM 7615-123-CA02-2PLM ..... . .......... * ------------- ................ ..... w...,......._»........».,....-...._...,.» ...... 7615-124-CA02-3 ....................... ...,.,...,»........................... *"'* ................. ............... ,.....,»,..».............».,..._.»....,,.,..... PLM 7615-100-CDW01-1 PLM ............................................................. l' 7615 105-CpW01 2 ............... ............... ............... 'PLM ,,_...........,»..,,..,............. 7615-119-CDW01-3 .......... PLM 7615-120-CDW01-4 PLM 7615416-CDW01-5 PLM 17 7615-106-CDW01-6 PLM 7615-122-CDW0I-7 PLM P1 7615-127-CDW01-8 PLM PLM Total Number of Samples: Sample Condition (Accept/Reject): Requested Turnaround Time: (X) RUSH )Next Day ( ) 3-5 Days RUSH Turnaround "!Y7 required prior notification. Additional fees may apply, Call lab for more details Relinquished by: Date/Time: /r, f -I, Received by; Date/Time: izzlzzl_ =120", Relinquished by: Date/Time: Received by: Date/Time: Document No: FCF-04.00 4 Effective Date: 10/17/2013 70 Page _2_ of LD River North Environmental Testing, Inc 3650 Chestnut Place * Denver, CO 80216 Ph: 303-297-0079 & Fax: 303-292-1451 www.rnetesting.com 9 info@rnetesting.com Client: Family Environmental Compliance Services Contact: Jerome Hairston, Josh Sieger Address: 3650 Chestnut Place Denver, CO 80213 Phone M 303-296-6022 Fax #/Email: Date Sampled: 12/27/2016 Sample Location: 7615 W. 38th Ave. Lab ID (for lab use only) Client ID Description Type of Analysis Volume/Other 7615-122-FLCOl-1 PLM . 7615-126-FLCOl-2 .. ........... PLM . . . ........... ...... . .. . . ... . ....... 7615-127-17LC01-3 . ..... . . ... . .. PLM . ...... ............ 7615-100-FTC01-1 ------ PLM 7615-100-FTCO2-1 PLM 7615-104-FTC03.1 ............. - PLM -77 7615-110-FTC04-1PLM .......... ............ ,....., ....... 7615-111 FTCO4-2 ...... PLM -7q 7615-114-FTC04-3 PLM 3() ......... 7615-118-FTCO5-1 ... PLM .......... 31 i 0"** ................ -12H FT..... .................. .....................-'*'............. PLM .......... ............. ..............iii ..". .*" .C* 7615-125-FTC07.1 . . ..... PLM 7�1�426-FTC07-2 PLM ............... -FTC07-3 ........ PLM .............. 761S-100-LIPOI-1 PLM ........... . ....... . . PLM ............. ........... Z.?_ �7615-121-LIP01-3 ........... PLM 7615-104-LIP02- .......................................- .... ......... 7615 19-LIP02-2 ..... PLM ,Y/k 17615-121-LIP02-3 PLM ��17615�419-LIP03-1 PLM Total Number of Samples: Sample Condition (Accept/Reject): Requested Turnaround Time: (X) RUSH )Next Day 3-5 Days RUSH Turnaround times required prior notification. Additional fees may apply. Call lab for more details. Relinquished by. Date/Time: Received by, Date/Time: 7 Relinquished by: Date/Time: Received by: Date/Time: EM Address: 3650 Chestnut Place Denver, CO 80213 Mi PL' 1011 f I I 17- Page -a of -�— 3650 Chestnut Place 9 Denver, CO 80216 Ph: 303-297-0079 a Fax: 303-292-1451 www.rnetesting.com 9 info@rnetesting.com Ir"4*41 Phone #: 303-296-6022 Fax #/Email:lqairstr�r ivan�iivenvirc i naentai. � Lsieger @familyerIvironmental,com Date Sampled: '7 6 1 Av-- Sample Location: Special instructions: Lab ID (for lab use only) Client ID Description Type of Analysis Volume/Other 777-u �L-�' � 1- 7615-121-LIP03-2 PLM 7615 121 L IP03-3 P LIM 7615-106-LIP04-1 .......... PLM 2��15-106-1-]F`04-2 PLIVI 7615-106-LIP04-3 PLM 7615-122-LIPOS-1 PLM .......................................................... -127-LIPOS-2 .......... PLM 7615-123-LIMS-3 PLM ' ....... . ........... ................................. 2 2 M- " A** '0' 1, *-' '1 ............... ''.......... . ......... .......................................... PLM 76I5-105-SVF01-1 PLM 7615-104-SVFOI-2 PLM 7615-115-SVF0I-3 PLM 7615-117-SVF01-4 PLM 7615-120-SVF02-1 ... ........ PLM 7615-106-SVF02-2 PLM 76I5-100-TS01-1 PLM ��-1054501-2 .............. PLM........ 7615-104-TS01-3 . .. . .......... PLM 7615-103-TS01-4 PLM 761 - 103-TS01-5 .......... PLM 17615-122-TS01-6 JPLM q z (e 2 - Total Number of Samples: Sample Condition (Accept/Reject). alCl Requested Turnaround Time: (X) RUSH )Next Day ( ) 3-5 Days RUSH Turnaround times required prior notification. Additional fees may apply. Call lab for more details. Relinquished by: ------------- hvµDate/Time: C' Received by: Date/Time: Relinquished by: Date/Time: Received by: Date/Time: Document No: FCF-04.00 Effective Date: 10/17/2013 Page 4 -of -1 River North Environmental Testing, Inc N- 46-E 3650 Chestnut Place 9 Denver, CO 80216 Ph: 303-297-0079 a Fax: 303-292-1451 www.rnetesting.com a info@rnetesting.com Client: Family Environmental Compliance Services Contact: Jerome Hairston, Josh Sieger Address: 3650 Chestnut Place Denver, CO 80213 Fax #/Email: Jhai r 'Wf amilvenvironmental . con jsie erefamilyenvironmentai.COM Date Sampled: 12/27/2016 Sample Location: 7615 W 38TH AVE Special Instructions: Lab ID (for lab use only) Client ID Description Type of Analysis Volume/Other 1�_.. 7615427-TS01-7 .............. PLM 7615-119-TS02-1 PLM 7615-120-TS02-2 .......... .......... . PLM 7615-116-TS02-3 PLM a l 7615 106 4 PCM 7615-123-TS02-5 PLM -7& 7615-125-TS02-7 PLM 7!7615-106-UC01-1 PLM .............. --- --- .. .... 7615-121-UC01-2 PLM . . ... . ..... .......... ........... 7 61 5 1 2 1-U C 0 1 3 .. .. ... .......... ..... PL M ...... . ... . .. ........ Total Number of Samples: -7 Sample condition (Accept/Reject): ---L-L- Requested Turnaround Time: (X) RUSH -** ( )Next Day 3-5 Days RUSH Turnaround times required prior notification. Additional fees may apply. Call tab for more details, Relinquished by, Date/Time: Received by: Date/Time: t 47 4—�', 47 7770�,, Relinquished by: Date/Time: Received by: Date/Time: FdMi3650 Chestnut Place, Denver, Colorado 80216 WFMTUMI Phone: 303.296.6022 / Fax: 303.292.1451 INSPECTOR CERTIFICATIONS City of jo'Wh6atPj, COAMUNi-ty DEVELOPNiENT Building & Inspection Services Division 7500 W. 29°i Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a)ci.wheatrid-ge.co,us FOR OFFICE USE ONLY Date: Q1311 � Plan/Permit # �010 i y Y Plan Review Fee: -$ 2 2,4ti cl+, Building Permit Application 7615 W. 38th Avenue, Suite B101 arA41*99 propeytnrrier (please print): Wilmore 38, LLC 720-412-8864 Property jdire@dpccompanies.com (if different than property address) Address: 7000 E Belleview Ave, Suite 300 City, State, Zip: Greenwood Village, CO 80111 1A Interior Architects -Tony Deagan t.deagan@interiorarchitects.com t303.672.8516hane :m Con d #.'� 1(A4d&iS: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License Complete all information on BOTH sides of this form Q COMMERCIAL (Check all that apply) ❑ RESIDENTIAL ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ® MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ® PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ® ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) Commercial Remodel A 5,097 square foot tenant improvement project including selective demolition of existing tenant suite and expansion into another tenant suite for Rocky Mountain Foot and Ankle. New space layout, ceiling layout, mechanical, plumbing and electrical layout as well as new finishes throughout. Sq. FULF 5,097 sa. ft. Btu's 180,000 Gallons GPM is 17GPM Amps 274 Amps at 208V 30 Squares Other ProjeCx 1/alie< (contract value or the cost of all materials and labor included in the entire project) $ 458,730 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CLK(EONE WNER (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) EI�ctiomc SisrnaturOaf stnda�are ;4 0 Building Division Valuation: $ I! \ INTERIOR ARCHITECTS TRANSMITTAL Attn: Project Name: Rocky Mountain Foot & Ankle Center Company: City of Wheat Ridge City Hall Project No: 16RMFA.0001.000 Address: 7500 W. 291h Ave. Location: Wilmore Center, 7615 W. 381h Ave. 2nd Floor Suite B101 and B129 Wheat Ridge, CO 80033 Wheat Ridge, CO 80033 Date: October 28, 2016 Telephone #: (303) 234-5900 Via: (method) Overnight cc: For Email or Fax: ❑ Email address . There is (are) page(s) of information in addition to this cover page. If you experience any problems in the transmission, contact at , ext. Transmitted: ❑ As Requested ❑ For Your Use ❑ Note & Return ® For Approval ❑ Revise & Resubmit ❑ For Review & Comment ❑ Reviewed as Noted ❑ No Exceptions Taken ❑ Rejected: Resubmit Dated Copies Document No. Description 10/27/2016 2 1 Rocky Mountain Foot & Ankle Center Architectural Drawings— Issued for Construction, Bid & Permit 10/27/2016 2 2 Rocky Mountain Foot & Ankle Center Engineer Drawings— Issued for Construction, Bid & Permit Remarks: Sender's Name: Brie Samyn Phone: 303.672.8504 Email: b.samyn@intenorqffchitects.com Sender's Signature: INTERIOR ARCHITECTS 500 SANSOME STREET, 8TH FLOOR SAN FRANCISCO, CA 94111 TEL 415.434.3305 FAX 415.434.0330 Interior Architects, Inc., a California corporation in AK, AL, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OK, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY / Interior Architects, P.C., a New York professional services corp—tion in AR, DC, CA, ID, IA, ME, MD, MS, MT, ND, NV, NY, NC, OH, OR, PA / Interior Architects, P.C, db. Interior Architects, professional corporafion in RI / Inferior Architects New Jersey PC, a New Jersey professional corporafion in NJ and CT / Inrador Archeeds, P.C. db. IA Inre6or Archireds in It, / Intedor Architects, P.C., license #AA26001062 in FL / Intedor A,&it.cn, P.C. dba Interior Architects, o professional corporafion in LA /Intedor Architects, Inc., o Colorado corporation in CO, MI / IA Intedor Architects Inc., "Holder of Cerfificate of Practice, Architedorol Insfimre of British Columbia, Aberto Association of Architects and Ontario Association of Architects" in Bdfish Colum6io, Alberto, and Ontario, Canada Page 1 of 2 ( A INTERIOR ARCHITECTS TRANSMITTAL Attn: Project Name: Rocky Mountain Foot & Ankle Center Company: City of Wheat Ridge City Hall Project No: 16RMFA.0001.000 Address: 7500 W. 29th Ave. Location: Wilmore Center, 7615 W. 38th Ave. 2nd Floor Suite B101 and B129 Wheat Ridge, CO 80033 Wheat Ridge, CO 80033 Date: October 28, 2016 Telephone #-. (303) 234-5900 Via: (method) Overnight cc: For Email or Fax: ❑ Email address . There is (are) page(s) of information in addition to this cover page. If you experience any problems in the transmission, contact at , ext. Transmitted: ❑ As Requested ❑ For Your Use ❑ Note & Return ® For Approval ❑ Revise & Resubmit ❑ For Review & Comment ❑ Reviewed as Noted ❑ No Exceptions Taken ❑ Rejected: Resubmit Dated Copies Document No. Description 10/27/2016 2 1 Rocky Mountain Foot & Ankle Center Architectural Drawings— Issued for Construction, Bid & Permit 10/27/2016 2 2 Rocky Mountain Foot & Ankle Center Engineer Drawings— Issued for Construction, Bid & Permit Remarks: Sender's Name: Brie Samyn Phone: 303.672.8504 Email: b.samyn@interiorarchitects.com Sender's Signature: k / INTERIOR ARCHITECTS 500 SANSOME STR T, 8TH FLOOR SAN FRANCISCO, CA 94111 TEL 415.434.3305 FAX 415.434.0330 Interior .Architects, Inc, a California corporation in AK, AL, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OK, SC, SD, TN, TX, UT, VA, Vi, WA, WI, WV, WY / Interior Architects, P.C., a New York professional services corporation in AR, DC, GA, ID, IA, ME, MD, MS, MT, ND, NV, NY, NC, OH, OR, PA / Interior Architects, P.C. d6a Interior Architects, professional corpomFoo in RI / Interior Architects New, Jersey PC, a New Jersey professional corporanon in W and CT / In, Architecn, P.C. db, IA Interior Architects in IL / Interior Architects, P.C., license #AA26001062 in EL / Interior Architects, P.C. db. Interior Architects, a professional corporation in LA / Interior Architects, Inc., a Colorado corporation in CO, MI / IA Interior Architects Inc., "Holder of Certificate of Practice, Architectural Institute of British Columbia, Al6eda Association of Architects and Ontario Association of Architects" in British Colombia, Alberta, and Ontario, Canada Page 1 of 2 AIINTERi0R ARCHITECTS TRANSMITTAL Attn: Justin Puente Project Name: Rocky Mountain Foot and Ankle I Company: Grayson Construction Project No: 16RMFA.0001 Address: 3722 Chestnut Place Location: Wheat Ridge, Colorado Denver, CO 80120 Date: January 10, 2017 Telephone #: Via: (method) Messenger cc: For Email or Fax: ❑ Email address . There is (are) page(s) of information in addition to this cover page. If you experience any problems in the transmission, contact at , ext. Transmitted: ❑ As Requested ❑ For Your Use ❑ Note & Return ❑ For Approval ❑ Revise & Resubmit ❑ For Review & Comment ❑ Reviewed as Noted ❑ No Exceptions Taken ❑ Rejected: Resubmit Dated Copies Document No. Description 01/03/17 2 City Comments Letter 12/21/16 2 P-7.1 Plumbing Schedules 12/21/16 2 E-7.1 Electrical Schedules 01/03/17 2 AN -4.0 Exiting Diagram Remarks: Enclosed items need to be delivered to the City of Wheat Ridge and insert into the permit drawing sets for complete review for final permit. Sender's Name: Emily Sinclair Phone: 303.672.8502 Email: e.sinclair@interiorarchitects.com Sender's Signature: INTERIOR ARCHITECTS 1750 15TH STREET, 3RD FLOOR DENVER, CO 80202 TEL 303.672.8500 FAX 888.990.0489 Interior Architects, Inc., a California corporation in AK, AL, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OK, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY / Interior Architects, P -C., a New York professional services corporation in AR, DC, GA, IN, IA, ME, MD, MS, MT, ND, NV, NY, NC, ON, OR, PA / Interior Architects, P.C. dbo Interior Architects, professional corporation in RI / Interior Architects New Jersey PC, a New Jersey professional corporation in NJ and CT / Interior Architects, P.C. db, IA Interior Architects in IL / Interior Architects, P.C., license #AA26001062 in FL / Interior Architects, P.C. dba Interior Architects, a professional corpora — in IA / Interior Architects, Inc., a Colorado corporation in CO, MI / IA Interior Architects Inc., "Holder of Certificate of Practice, Architectural Institute of British Columbia, Alban. A—dation of Architects and Ontario Association of Architects" in British Columbia, Aberto, and Omodo, Canada Page 1 of 1 r x 1A - --------- INTERIOR January 3, 2017 AR��iTECTS � �- i 'I City of Wheat Ridge Community Development , 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 ,-17 Re: Brian Tardif RE: 7615 W Avenue, Suite B101 Wheat Ridge, Colorado Brian Tardif, The following is our response to the comments below ATLANTA Architectural: BOSTON CHARLOTTE A. The plans list two suite numbers Suite 13101 and Suite 13129. The plans must only show one suite no. The Suite no. that is currently being used by this company will CHICAGO remain the same and the 8101 and 13129 will not be used. DALLAS IA: The current tenant suite is 8135, the suite number has been revised on DENVER all drawing titleblocks and only Suite B135 suite number will be used to designate the suite. HOUSTON B. Occupant load for the waiting areas was based on 1/30 and we have the LONDON waiting areas 1/15. This adds 10 to the total occupant load bringing the number LOS ANGELES from 70 to 80. This does not change the plans other than the occupant loading. MIAMI IA: Updated drawings reflect 10 additional occupants, refer to updated Exiting Diagram AN -4.0. NEW YORK ORANGE COUNTY C. In the plumbing calculation you show 2 woman's bathrooms and 2 men's bathrooms and we agree with these calculations, but on the plans you show for 1 PORTLAND woman ,1 man , (unisex are not allowed) and 1 Dr. bathroom. RALEIGH IA: Updated drawing reflect the revise naming of the Unisex restroom and SAN FRANCISCO the Dr. restroom, refer to updated Existing Diagram AN -4.0. SEATTLE Electrical: SILICON VALLEY D. We need Emergency lighting schedule. TORONTO IA: Luminaire schedule on sheet E7.1 lists all luminaires. Fixtures ending in WASHINGTON, DC "E" are emergency lights with the battery backup option. 1750 15TH STREET E. Need Asbestos demolition approval from the state 3RD FLOOR DENVER, CO aozoz IA: Refer to attached letter of inspection for asbestos containing material 303.672. 858500 P 9 888.990.0489 FAX dated December 28, 2016. www.interiorarchitects.com IA INTERIOR ARCHITECTS GLOBAL ALLIANCE Interior Architects, Inc., a California corporation in AK, At, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OR, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY / Interior Architects, P.C., o New York professional —ices corporation in AR, DC, GA, ID, IA, ME, MD, MS, MT, ND, NV, NY, INC, ON, OR, PA / Interior Architects, P.C. dba Interior Architects, professional corporation in RI / Interior Architects New Jersey PC, a New Jersey professional corporation in NJ and CT / Interior Ammlects, P.C. dba IA Interior Architects in IL / Interior Architects, P.C., license #AA26001062 in FL / Interior Architects, P.C. d'oa Interior Architects, a professional corporation in LA / Interior Architects, Inc., a Colorado corporation in CO, MI / IA Interior Architects Inc., "Holder of Certificate of Practice, Architectural Institute of British Colombia, Alberta Association of Architects and Ontario Association of Architects" in British Columbia, Alberta, and Ontario, Canada January 3, 2017 1A Page 2of 2 INTEP10R ARCHITECTS Plumbing: F. Need expansion tanks on the hot water heaters. IA: Attached sheet P-7.1 shows spec for expansion tank on all water heaters. Electrical: G. Need to identify R-1 E on sheet no. E2.1 . IA: Refer to Luminaire Schedule on E-7.1, R-1 E is a 2X2 LED Recessed Troffer with Dimming and Battery Back -Up and the fixtures are tagged in the plans. H. The Interior Lighting Certificate is not signed. IA: See attached signed and stamped copy of sheetE-7.1 with interior comcheck. I. The Branch Panel L2 Load is off please check. It shows that the continuous load at 32642 and the estimated demand load at 32815. IA: The load of 32642 VA is labeled as "Total Conn. Load" no continuous. This load is less than the total estimated demand due to lighting having a demand factor of 125%. J. The plans show the x-ray room is not requiring lead glass. Please check? IA: Refer to sheet A-1 A Physicist Report provided in the Construction Documents. Sincerely, K__Y�&Q ZV z Emily Sinclair Attachments: AN -4.0 E-7.1 P-7.1 Asbestos Inspection Report_7615 W38th Ave Final Report Interior Architects, Inc., a California corporation in AK, At, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OR, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY / Interior Architects, P.0-, a New York professional services corporation in AR, DC, CA, ID, IA, ME, MD, MS, MT, ND, NV, NY, NC, ON, OR, PA / Interior Architects, P.C. dba Interior Architects, professional corporation in RI / Interior Architects New Jersey PC, a New Jersey Professional corporation in NJ and CT / Interior Architects, P.C. dba IA Interior Architects in It / Interior Architects, P.C., license #AA260D1062 in FL / Interior Architects, P.C. dba Interior Architects, a professional corporation in LA / Interior Architects, Inc., o Colorado corporation in CO, MI / IA Interior Architects Inc., "Holder of Certificate of Practice, Architectural Institute of British Columbia, Alberta Association of Architects and Ontario Association of Architects" in British Columbia, AI'oerta, and Ontario, Canada 1A INTER€0R ARCHITECTS January 3, 2017 City of Wheat Ridge f Community Development s 7500 W. 29th AvenueLJ Wheat Ridge, Colorado 80033 Re: Brian Tardif RE: 7615 W Avenue, Suite B101 Wheat Ridge, Colorado The following is our response to the comments below: ATLANTA Architectural: BOSTON CHARLOTTE A. The plans list two suite numbers Suite B101 and Suite B129. The plans must only show one suite no. The Suite no. that is currently being used by this company will CHICAGO remain the same and the B101 and B129 will not be used. DALLAS IA: The current tenant suite is 8135, the suite number has been revised on DENVER all drawing titleblocks and only Suite 8135 suite number will be used to designate the suite. HOUSTON B. Occupant load for the waiting areas was based on 1/30 and we have the LONDON waiting areas 1/15. This adds 10 to the total occupant load bringing the number LOS ANGELES from 70 to 80. This does not change the plans other than the occupant loading. MIAMI IA: Updated drawings reflect 10 additional occupants, refer to updated NEW YORK Exiting Diagram AN -4.0. ORANGE COUNTY C. In the plumbing calculation you show 2 woman's bathrooms and 2 men's bathrooms and we agree with these calculations, but on the plans you show for 1 PORTLAND woman ,1 man , (unisex are not allowed) and 1 Dr. bathroom. RALEIGH IA: Updated drawing reflect the revise naming of the Unisex restroom and SAN FRANCISCO the Dr. restroom, refer to updated Existing Diagram AN -4.0. SEATTLE Electrical: SILICON VALLEY D. We need Emergency lighting schedule. TORONTO IA: Luminaire schedule on sheet E7.1 lists all luminaires. Fixtures ending in WASHINGTON, DC "E" are emergency lights with the battery backup option. 1750 15TH STREET E. Need Asbestos demolition approval from the state. 3RD FLOOR DENVER, 80202 IA: Refer to attached letter of inspection for asbestos containing material 303.672.8585 00 P 9 888.990.0489 FAX dated December 28, 2016. www.interiorarchitects.com IA INTERIOR ARCHITECTS GLOBAL ALLIANCE Interior Architects, Inc., a Cphfornia corporation in AK, AL, A7, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OK, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY / Interior Architects, P.C., a New York professional services corporation in AR, DC, GA, ID, IA, ME, MD, MS, MT, ND, NV, NY, NC, OH, OR, PA / Interior Architects, P.C. dba Interior Architects, professional corporation in RI / Interior Architects New Jersey PC, a New Jersey professional corporation in NJ and CT / Interior Architects, P.C. dba IA Interior Architects in It / Interior Architects, P.C., license #AA26001062 in FL / Interior Architects, P.C. dba InteriorArchilects, a professional corporation in LA / Interior Architects, Inc., a Colorado corporation in CO, MI / IA Interior Architects Inc., 'Holder of Certificate of Practice, Architectural Institute of British Columbia, Alberta Association of Architects and Ontario Association of Architects" in British Colurnbio, Alberta, and Ontario, Canada January 3, 2017 1A Page 2of 2 I N T E R 1 0 R ARCHITECTS Plumbing: F. Need expansion tanks on the hot water heaters. IA: Attached sheet P-7.1 shows spec for expansion tank on all water heaters. Electrical: G. Need to identify R-1 E on sheet no. E2.1. IA: Refer to Luminaire Schedule on E-7.1, R-1 E is a 2X2 LED Recessed Troffer with Dimming and Battery Back -Up and the fixtures are tagged in the plans. H. The Interior Lighting Certificate is not signed. IA: See attached signed and stamped copy of sheetE-7.1 with interior comcheck. I. The Branch Panel L2 Load is off please check. It shows that the continuous load at 32642 and the estimated demand load at 32815. IA: The load of 32642 VA is labeled as "Total Conn. Load" no continuous. This load is less than the total estimated demand due to lighting having a demand factor of 125%. J. The plans show the x-ray room is not requiring lead glass. Please check? IA: Refer to sheet A-1.1 Physicist Report provided in the Construction Documents. Sincerely, Emily Sinclair Attachments: AN -4.0 E-7.1 P-7.1 Asbestos Inspection Report_7615 W38th Ave Final Report Interior Architects, Inc., a California corporation in AK, AL, AZ, CA, DE, HI, IN, KS, KY, MA, MN, MO, NE, NH, NM, OK, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY / Interior Architects, P.C., a New York professional services corporation in AR, DC, CA, ID, IA, ME, MD, MS, MT, ND, NV, NY, NC, OH, OR, PA / Interior Architects, P.C. dba Interior Architects, professional corporation in RI / Interior Architects New Jersey PC, o New Jersey professional corporation in NJ and CT / Interior Architects, P.C. dba IA Interior Architects in IL /Interior Architects, P.C., license #AA26D01062 in FL / Interior Architects, P.C. dba Interior Architects, a professional corporation in LA / Interior Architects, Inc., a Colorado corporation in CO, MI / IA Interior Architects Inc., "Holder of Certificate of Practice, Architectural In,tiWt. of British Columbia, Alberta Association of Architects and Ontario Association of Architects" in British Columbia, Alberta, and Ontario, Canada Brian Tardif To: t.deagan@interiorarchitects.com Subject: Plans for 761 S W 38th Av Suite B101 Hi Tony, We are working on the approval for the plans for 7615 W38th Av. Suite B101. Please find below the list of questions that we have on the plans. A- The plans list two suite numbers Suite B101 and Suite B129. The plans must only show One Suite no. The Suite no. that that is currently being used by this company will remain the same and the B101 and B129 will not be used. B- Occupant load for the waiting areas was based on 1/30 and we have the waiting areas 1/15. This adds 10 to the total occupant load bringing the number from 70 to 80. This does not change the plans other than the occupant loading. C- In the plumbing calculation you show 2 woman's bathrooms and 2 men's bathrooms and we agree with these calculations, but on the plans you show for 1 woman ,1 man , ( unisex are not allowed) and 1 Dr. bathroom. D- We need Emergency lighting schedule E- Need Asbestos demolition approval from the state F- Need expansion tanks on the hot water heaters G- Need to identify R -1E on sheet no E2.1 H- The Interior Lighting Certificate is not signed I- The Branch Panel L2 Load is off Please check. It shows that the continuous load at 32642 and the estimated demand load at 32815 J- The plans show the x-ray room is not requiring lead glass. Please check? Thank You Tian Tardif Combination Inspector/ Plan Examiner 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2850 Fax: 303-237-8929 www.d.wheatriclRe.co.us CiI4 (,A t . CONFIDENTIALITY NOTICE: This e -nail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. City of Wheat Ridge 1 Commercial Demolitio PERMIT - 201700006 PERMIT NO: 201700006 ISSUED: 01/03/2017 JOB ADDRESS: 7615 W 38th AVE UNIT B101 EXPIRES: 01/03/2018 JOB DESCRIPTION: Demolition of walls, ceilings, floors, fixtures from existing space - 5600 sq ft. *** CONTACTS *** OWNER DPC DEVELOPMENT COMPANY GC (303)710-5656 Ken J Baney 160285 KJB Enterprises LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 333 / BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,200.00 FEES Total Valuation 0.00. Demolition Fee 50.00 * * TOTAL * * 50.00 *** COMMENTS *** *** CONDITIONS *** All work shall comply with applicable codes and ordinances and is subject to field inspections. I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER CONTRACTOR (Circle one) Date I. This permit was iss d based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offcial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any rdmance or regulation of this jurisdiction. Approval of work is subject to field inspection. .. 1/3I/-_7 Signature of Chief Building Official Date I I REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of WheatRjge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: Plan/Permit #��� l Plan Review Fee: t(� Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: "7615- t j 3 q "' A µ2.r �4=- 1�p 10 1 Owner (please print): 1 ) Y(l Uo, )>;��: Property Owner Email: Phone: Mailing Address: (if different than property address) Address: � � Jay �� �� t r�a �1 Ju c� z L State, Zip: V i U ..l.n`Icf4c.�2-9i2crrrt��� . �G�? Arch itectlEngineer E-mail: Phone: -?03-b7..9 - Contractor: Z L C - Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: �3D27) b L 6S� Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTE /APPLI N E REPAIR or REPLACEMENT Q.OTHER (Describe) a (For ALL projects, please provide a detailed description of work to be perfbrmed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) �`"�[ kk -e-x ; - Is i Sq. FULF S6 65�0 Btu's Amps Squares 7�_/,-V r Lf� Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ su bo— ;<-��res OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER)(�(CONTRACTO�) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: ZONING COMMMENTS Reviewer BUILDING DEPARTMENT COMMENTS Reviewer. PUBLIC WORKS COMMENTS Reviewer PROOF OF SUBMISSION FORMS SIGNATURE: Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY DATE: OCCUPANCY CLASSIFICATION, Building Division Valuation: $ tJ( 3650 Chestnut Place, Denver, Colorado 80216 �I�IJJ Phone. 303.296.6022 /Fax: 303.292.1451 December 28, 2016 Grayson Construction, LLC via Email: justinpuente96ggmail.com Justin Puente 3722 Chestnut Place Denver, Colorado 80120 RE: Inspection for Asbestos -Containing Materials 7615 W. 38th Ave. Wheat Ridge, CO 80033 Family Environmental Project Number: 122116-1 Dear Justin Puente, Family Environmental Compliance Services, Inc. (Family Environmental) is pleased to submit this report summarizing the inspection activities conducted at the building located at 7615 W. 38`x' Ave., Wheat Ridge, Colorado 80033 (the Site). Family Environmental was contracted by Justin Puente (the Client) on December 21, 2016 to inspect and identify suspected Asbestos Containing Material (ACM), collect and submit samples for laboratory analysis, and provide an inspection report. Fieldwork was performed on Tuesday December 27, 2016. Data gathered during the visual inspection of the Site, collection of bulk samples of inspected suspect building materials, and the interpretation of analytical results is intended to provide information that meets federal, state, and local regulatory requirements. The sampling and inspection process was conducted in accordance with the following standards: • Asbestos Hazard Emergency Response Act (AHERA) — 40 CFR 763 Subpart E sections 763.80 to 763.99 • Colorado Department of Public Health & Environment (CDPHE) Regulation Number 8 (Reg. 8) • United States Environmental Protection Agency (EPA) National Emissions Standards for Hazardous Air Pollutants (NESHAP) — 40 CFR 61 Part M • Occupational Safety and Health Administration (OSHA) asbestos regulations — 29 CFR 1926 parts 58 and 1101, and 29 CFR 1910 Parts 134 and 1001 1.0 REGULATORY COMPLIANCE This limited inspection was performed in anticipation of demolition activates that are expected to impact suspected asbestos containing building materials. Asbestos has been added to over 3,000 materials and products produced and used in the United States. Suspected ACMs include nearly all building materials with the exception of glass, metal or rubber. According to AHERA and CDPHE Reg. 8, suspect ACMs must be properly sampled and submitted for analysis before any disturbance occurs at the Site. For a building material to be categorized as ACM, it must contain asbestos in a quantity greater than one percent, as confirmed by an EPA accredited National Voluntary Laboratory Accreditation Program (NVLAP) laboratory. ACMs are categorized into two subsequent categories, non -friable asbestos and friable asbestos. Non -friable asbestos is any material that cannot be crumbled, 3650 Chestnut Place, Denver, Colorado 80216 raml rpurkdl Phone: 303.296.6022 / Fax: 303.292.1451 pulverized or reduced to a powder by hand pressure when dry. Friable asbestos can be crumbled, pulverized, or reduced to a powder by hand pressure when dry. ACMs identified in this report are subject to the EPA NESHAP Regulations for Asbestos and the CDPHE Reg. 8. The CDPHE is responsible for the administration of the EPA NESHAP program in Colorado. EPA NESHAP prohibits the release of asbestos fibers into the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated ACMs be identified, classified, quantified and removed where necessary prior disturbance. All friable ACM as well as non -friable ACM that can be rendered friable during demolition or renovation activities must be removed by a licensed General Abatement Contractor (GAC). Materials containing asbestos quantities of one percent (1%) or less are also be subject to OSHA regulations if air concentrations sampled during demolition or renovation activities are at or above the permissible exposure limit (PEL) of 0.10 fibers per cubic centimeter (f/cc) as an eight hour time weighted average, or the excursion limit of 1.0 f/cc as averaged over a 30 minute sampling period. OSHA regulations for General Industry and the Construction Industry include provisions for communication of hazards by the building owner, to building employees, or in the case of subcontracted building services, the subcontractor to subcontractor employees: The employer must inform maintenance staff and subcontractors if building components have the potential to expose staff and subcontractors to asbestos. The building owner shall maintain records concerning the presence, location and quantity of ACMs in the building for the duration of ownership, and records shall be transferred to any successive owners. The building owner shall affix labels or signs to positively identified ACMs so that employees and building visitors will be notified of materials that contain asbestos. Such labels or signs shall be placed in areas where employees are likely to impact ACMs as a part of their work. 2.0 SITE / BUILDING INFORMATION The subject building is located at 7615 W. 38`h Ave., Wheat Ridge, Colorado 80033. This was a pre -renovation investigation. Drawings of the existing conditions and renovation designs were provided to Family Environmental prior to the inspection and sampling activities. �I 3650 Chestnut Place, Denver, Colorado 80216 Phone: 303.296.6022 /Fax: 303.292.1451 The building is primarily composed of concrete block, steel and drywall construction. The inspected area are detailed in the drawings provided in Appendix B. During the inspection, the inspector was able to identify and inspect: • Twenty -Eight (28) functional spaces were identified. • Twenty -Eight (28) functional spaces were surveyed. 3.0 FIELD ACTIVITIES On Tuesday December 27, 2016, an AHERA/CDPHE accredited asbestos inspector from Family Environmental conducted a limited asbestos inspection of the Site. The purpose of this asbestos inspection was to evaluate for the presence of ACM in the structure. The inspection was conducted in accordance with the methods and procedures outlined in the aforementioned documents. 3.1 Visual Assessment Inspection activities began with visual observation of interior and exterior of the shop to identify homogeneous areas for suspect ACM. Homogenous areas (materials) are classified into one of the following three categories: • Surfacing Material (S) refers to a wide range of trowel or spray -applied materials typically used for acoustical, decorative or fire proofing purposes. • Thermal System Insulation (TSI) refers to insulation that is applied to heating or mechanical system components. Examples include pipe, tank and boiler insulation. • Miscellaneous Materials (M) refers to refers to all other materials that do not fall into one of the previously mentioned categories. Examples include floor tiles, adhesives, composite drywall systems and ceiling tiles. Appendix A provides a summary of the areas determined to be homogeneous and the laboratory results for those areas. 3.2 Physical Assessment and Sample Collection A tactile assessment of each homogeneous area of suspect ACM was conducted to assess the general condition and the friability of the material. Friability was assessed by physically touching suspect materials. Following categorization for material type and friability, a sampling strategy was developed based on the following requirements: Bulk Sampling Strategy Material Homogenous Area Units Minimum Samples Surfacing (S) Less than 1,000 1,000 to 5,000 More than 5,000 SF 3 5 7 Thermal System Insulation TSI --- LF/SF/EA 3 Miscellaneous Materials M --- LF/SF/EA I Inspectors discretion Jr = SQUARE FEE LF = LINEAR FEET EA = EACH 3650 Chestnut Place, Denver, Colorado 80216 ropqTpul Phone. 303.296.6022 /Fax: 303.292.1451 Based on the results of the visual observation, bulk samples of suspect ACM were collected in accordance with AHERA protocols. Random bulk samples of suspect materials were collected in each homogeneous area using wet methods as applicable to reduce the potential for fiber release. During the inspection, Family Environmental staff identified twenty-three (23) suspect homogenous materials, and collected seventy-three (73) bulk samples. The following major categories of homogenous areas were identified as being suspect asbestos containing materials: • Composite Drywall (CDW): One (1) unique CDW was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) CDW identified during this inspection was non -detect for asbestos. • Textured Surfacing (TSS: Two (2) unique TS's were identified during this inspection and two (2) were sampled. Laboratory analysis determined that the two (2) TS identified during this inspection were non -detect for asbestos. • Miscellaneous Adhesive (MA): One (1) unique MA was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) MA identified during this inspection was non -detect for asbestos. • Baseboard Adhesive (BBA): One (1) unique BBA was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) BBA identified during this inspection was non -detect for asbestos. • Carpet Adhesive (CA): Two (2) Unique CA's were identified during this inspection and two (2) were sampled. Laboratory analysis determined that the one (1) CA identified during this inspection was non -detect for asbestos • Floor Tile (TS): Seven (7) unique TS's were identified during this inspection and seven (7) were sampled. Laboratory analysis determined that the seven (7) TS's identified during this inspection were non -detect for asbestos. • Sink Undercoating (UC): One (1) unique UC was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) UC identified during this inspection was non -detect for asbestos. • Lay In Ceiling Panel (LIP): Five (5) unique LIP's were identified during this inspection, and five (5) were sampled. Laboratory analysis determined that the five (5) LIP's identified during this inspection was non -detect for asbestos. • Floor Leveling Compound (FLC): One (1) unique FLC was identified during this inspection, and one (1) was sampled. Laboratory analysis determined that the one (1) FLC identified during this inspection was non -detect for asbestos. Each sample was placed in a sealed container and labeled with a unique sample number using an indelible marker. Appendix C contains the Laboratory Analytical Summary of all of the bulk samples collected. 3.3 Chain of Custody Samples were delivered along with a completed chain -of -custody (COC) to River North Environmental Testing (RNET) Laboratory. Laboratory personnel signed and dated the COC at the time of delivery to acknowledge receipt of the samples. Upon receipt, the laboratory arranged the samples in numerical order to establish any discrepancies between the samples set which was delivered and the COC form. Where (if) discrepancies exist, laboratory personnel noted and initialed the COC and reported the error to the inspector. The laboratory included the signed original copy of the COC with the final analytical report for evidentiary purposes. [�dJ3650 Chestnut Place, Denver, Colorado 80216 Phone: 303.296.6022 /Fax: 303.292.1451 4.0 LABORATORY ANALYSIS All bulk samples were relinquished to RNET. All samples were analyzed via Polarized Light Microscope (PLM) in accordance with EPA/600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. RNET is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) under Laboratory Code 200448-0. A copy of the RNET Report of Test Results can be found in Appendix C of this report. 5.0 ASBESTOS CONTAINING MATERIALS The United States EPA and OSHA define an asbestos containing material as a material containing greater than 1% asbestos, or a material that is assumed to contain asbestos. Materials that contain asbestos at or below one percent (<1%) are considered to be trace asbestos containing. Current EPA and State of Colorado regulations require the removal of both confirmed, and assumed, FRIABLE ASBESTOS prior to renovation or demolition activities that will impact these materials. The following is a list of friable ACM observed by the inspector: • No friable asbestos was observed during this inspection. Depending on the renovation or demolition techniques used, the current EPA and State of Colorado regulations may require the removal of both confirmed, and assumed, NON -FRIABLE ASBESTOS prior to any activities that may impact these materials. The following is a list of non - friable ACM observed at the site: • No non -friable asbestos was observed during this inspection. Prior to any disturbance, the following ASSUMED ASBESTOS (ACM) should be sampled by a certified asbestos building inspector to determine the actual asbestos content, or be treated as asbestos containing: • No materials were assumed during this inspection. Current EPA and State of Colorado regulations do not require the removal of materials found to contain TRACE ASBESTOS (<I %) prior to initiating renovation or demolition activities that will impact this material. The following materials contain trace amounts of asbestos: • No trace (<1 %) asbestos was observed during this inspection. 6.0 CONCLUSIONS & RECOMMENDATIONS Based on our observations and the analytical results, no friable or non -friable asbestos is present in the area of the inspection. All non -friable or friable materials must be removed by a certified abatement contractor prior to renovation or demolition. If trace (<1%) asbestos materials exist on the site, and they are not removed, the renovation or demolition contractor must be notified of the presence of this material prior to disturbance and comply with all current OSHA regulations for employee exposure to asbestos. Additionally, the renovation or demolition contractor must comply with applicable NESHAP asbestos emission control regulations for structures containing trace amounts of asbestos. These materials may not be subject to sanding, grinding or cutting during renovation or demolition activities. I ropry-v3ptal 3650 Chestnut Place, Denver, Colorado 80216 Phone. 303.296.6022 /Fax: 303.292.1451 If during demolition/renovation activities, materials are encountered which have not been discussed in this report; stop all activities in the immediate area, and contact a certified asbestos building inspector to sample the suspect material. Family Environmental is available to perform further sampling at your request. 7.0 LIMITATIONS This asbestos inspection was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and/or recommendations expressed in this report are based on conditions observed during our limited inspection, and the analytical results of the samples collected. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This limited asbestos inspection report is not considered a comprehensive inspection report and it must be understood that the existence of unique or concealed asbestos may be possible. This report has been prepared on behalf of, and exclusively for use by the client for specific application to the project indicated. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Family Environmental does not warrant the work of regulatory agencies or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made. This report is not to be used as a bidding document. Should you have any questions or require additional information or services, please feel free to contact Family Environmental at (303) 296-6022. Sincerely, Family Environmental Compliance Services, Inc. Digitally signed by Josh Sieger DN: cn=Josh Sieger, o, ou, Josh Sieger email=jsieger@familyenvironmen tal.com, c=US Date: 2016.12.29 13:53:48 -07'00' Josh Sieger, Environmental Scientist AHERA/CDPHE Accredited Asbestos Building Inspector (CABI), Air Monitoring Specialist (AMS), Project Designer (PD) 10744 Attachments: Appendix A: Homogenous Materials Table Appendix B: Sample Location Drawings Appendix C: Laboratory Analytical Report Appendix D: Inspector Certifications Jerome B. Hairston, CIEC Industrial Hygiene Program Manager AHERA/CDPHE Accredited Asbestos Building Inspector (CABI), Air Monitoring Specialist (AMS), Project Designer (PD) 43799 rdm* * 3650 Chestnut Place, Denver, Colorado 80216 ropurkdI Phone. 303.c2�6.60_2 /Fax.. '30' ).292.1451 APPENDIX A HOMOGENOUS MATERIALS TABLE rdm* - iM ropurpta I---- 3650 Chestnut Place, Denver, Colorado 80216 Phone. 303.296.6022 /Fax: 303.292.1451 Homogenous Areas (Materials) Material Code Material Description Material Material Estimated Percent & Type of Material Locations Type Friability Quantity Asbestos BBA -01 Cream Baseboard Adhesive M NFII --- ND --- CA-01 Tan Carpet Adhesive M NFII ND --- CA-02 Remnant Carpet Adhesive M NFII --- ND --- FTC-01 Purple Floor Tile M NFI --- ND --- FTC-02 Orange Floor Tile M NFI --- ND --- FTC-03 Tan Floor Tile M NFI --- ND --- FTC-04 Blue Gray Mottled 12x12 Floor NFI Tile M --- ND -- FTC -05 Gray Mottled 12x12 Floor Tile M NFI --- ND --- FTC-06 Green 12x12 Floor Tile M NFI --- ND --- FTC-07 Gray, Black, and White Speckled M NFI 12x12 Floor Tile --- ND - CDW-01 White Drywall and Mud M NFII --- ND --- LIP-01 White 2x4 with Large Fissures F and Pinholes M ND --- LIP -02 White 2x4 Lay in Panel with F Large Craters and Small Pinholes M ND -- LIP -03 White 2x4 Lay in Panel with F Small Craters and Pinholes M ND -- LIP -04 2x4 Vinyl Faced Lay in Panel M F - ND --- LIP-05 White 2x4 Lay in Panel with F Small Fissure and Pinholes M - ND --- MA -01 Brown Counter Adhesive M NFII --- ND --- TS-01 Heavy Orange Peel S F --- ND --- TS-02 Light Orange Peel S F --- ND --- UC-01 Black Sink Undercoating M NFII --- ND --- SVF-01 Green Faux Tile Patterned Sheet M NFII Vinyl Flooring ND --- SVF 02 Light Green Marble Patterned NFII Sealed Sheet Vinyl Flooring M - ND -- rFLC-01 White Floor Leveling Compound cc -cnrr nc ccr•r S NFII --- ND --- LF = LINEAR FEET EA = EACH NO = NON DETECT FOR ASBESTOS rdmi 3650 Chestnut Place, Denver, Colorado £0216 ropawpu . Phone. 30.x._96.60_2 /Fax: 303.292.1451 APPENDIX B SAMPLE LOCATION DRAWINGS y.� t e aaN t4s � N. € 4 ram* 3650 Chestnut Place, Denver, Colorado 80216 �WropwdiPhone: 303.296.6022 / Fax: 303.292.1451 APPENDIX C LABORATORY SUMMARY OF BULK SAMPLES AND ANALYTICAL RESULTS ' River North Environmental Testing, Inc. IIIIIII� 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www metesting_corn info@metes ting, corn 12/28/2016 Family Environmental Services 3650 Chestnut Place Denver, Colorado 80216 Re: 7615 W. 38th Ave. PLM 16-570 Mr. Hairston, Attached are the results of Polarized Light Microscopic (PLM) analysis for asbestos contained in the bulk sample materials submitted to this facility on 12/28/2016 Bulk samples are analyzed in accordance with USEPA test method EPA/600/M4-82-020 and EPA/600/R- 93/116, which requires that distinctly different materials or layers present within a sample be analyzed and reported separately. (For measurement uncertainty, refer to table 2.1 in EPA/600/R-93/116 method.) Sometimes it is not possible to completely separate thin or strongly adhering layers, such as paint or adhesive, and a combined result is given. For some complex materials, such as drywall/tape/mud joints, a composite or overall asbestos content may be reported in addition to individual layer results. RNET, Inc. is currently accredited for bulk asbestos analysis by the National Voluntary Laboratory Accreditation Program (NVLAP) of the National Institute of Standards and Technology (NIST). Our NVLAP laboratory code number is 200448-0. Due to the limitations of the EPA 600 Method, nonfriable organically bound materials (NOBS) such as floor tiles can be difficult to analyze via PLM. EPA recommends that all NOBS reported as non -detect by PLM analysis be further analyzed by Transmission Electron Microscopy for more definitive results. Please note that the PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. The analytical results provided in this report apply only to the samples submitted to the laboratory. This report is confidential. Details of this report will not be discussed with any person or agency not associated with you or your organization. This report must be reproduced in its entirety and shall not be copied in part or used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. Samples will be held for a minimum of sixty days unless longer storage is requested. If you have any questions regarding the content of this report please call RNET, Inc. at 303-296-6022. Marissa Urdiales Asbestos Analyst murdiales@familyenvironmental.com Cell: 719-214-2837 9• NVLAP LabC 7e 2.�N4S.J kW4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www.metesting.com infoa@metesting com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM 16-570 Lab -ID No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type M Components (%) PLM16-570-01 7615-100-BBA01-1 Adhesive, Tan, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non -Fibrous 100% L M 16-570-02 ._.. .......... .._._. 7615-105-BBA01-2 Adhesive, Tan, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non -Fibrous 100% LM16-570-03 .__.......... _.......... _..._.._.-_________ .---_.__--._. 7615-104-BBA01-3 Adhesive, Tan, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non -Fibrous 100% PLM 16-574-04 . ........ ___.._._ _ _ _ . 7615-119-BBA01-4 Adhesive, Tan, Homogeneous, LAYER 1 None Detected Resinous 100% Other Non -Fibrous 100% PLM16-570-05 _..... _. ___„_ -- 7615-127-BBA01-5 Adhesive with Debris, Tan, Brown, and LAYER 1 None Detected Cellulose Fiber 45%4 Gray, Homogeneous, 100%n Other Non -Fibrous 55% Resinous/Fibrous Material PLM 16-570-06 7615-100-CA01-1 Adhesive, Yellow, Non- LAYER 1 None Detected Synthetic Fiber 5%e homogeneous, Resinous 100% Other Non -Fibrous 95% 16-570-07 ............_._.__ ___ _ 7615-119-CA01-2 Adhesive, Yellow, Non- LAYER 1 None Detected Synthetic Fiber 5% homogeneous, Resinous 100% Other Non -Fibrous 95% PLM 16-570-46 7615-121-CA01-3 Adhesive, Yellow, Non- LAYER 1 None Detected Synthetic Fiber 5% homogeneous, Resinous 100% Other Non -Fibrous 95% LM 16-570-09 7615-122-CA02-1 Adhesive, Yellow, Non- LAYER 1 None Detected Synthetic Fiber 5% homogeneous, Resinous 100% Other Non -Fibrous 95% -.LM16-570-10 _ ._-------- - —� ---------- 7615-123-CA02-2 LAYER 1 LAYER 1 None Detected Adhesive, Yellow, Homogeneous, 40% Other Non -Fibrous 100% Resinous Material LAYER 2 LAYER 2 None Detected Adhesive, Green, Homogeneous, 60% Other Non -Fibrous 100% Resinous Material Rage 1 of 13 River North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 w4T Denver, CO 80216 Fax 303-292-1451 www.metesting.com into@rnetesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab-ID No. Layer No. Asbestos Sample ID Description Layer % Type PLM16-570-11 7615-124-CA02-3 Adhesive, Yellow, Homogeneous, LAYER 1 None Detected Resinous 100% PLM16-570-12 7615-100-CDW01- LAYER 1 LAYER 1 None Detected 1 Drywall, Brown, Homogeneous, Fine 85% Grained/Fibrous LAYER 2 LAYER 2 None Detected Mud with Paint, White, 15% Homogeneous, Fine Grained PLM16-570-13 1510 7615-105-CDW01- LAYER 1 LAYER 1 2 Drywall, White and Brown, 90% Homogeneous, Fine Grained/Fibrous 100% LAYER 2 LAYER 2 Mud with Paint, White, Non- 5% homogeneous, Fine Grained LAYER 3 LAYER 3 Mud with Paint, White and Off White, 5% Non-homogeneous, Fine Grained PLM 16-570-14 7615-119-CDW01- LAYER 1 LAYER 1 3 Drywall, White and Brown, 90% Homogeneous, Fine Grained/Fibrous LAYER 2 LAYER 2 Mud with Paint, White, Non- 510 homogeneous, Fine Grained LAYER 3 LAYER 3 Mud with Paint, White and Off White, 5% Non-homogeneous, Fine Grained None Detected None Detected None Detected None Detected None Detected None Detected Non -Asbestos M Components M Other Non -Fibrous 100% Cellulose Fiber 15% Other Non -Fibrous 85% Material Other Non -Fibrous 100% Material Cellulose Fiber 1510 Other Non -Fibrous 85% Material Other Non -Fibrous 100% Material Other Non -Fibrous 100% Material Cellulose Fiber 15% Other Non -Fibrous 85% Material Other Non -Fibrous 100% Material Other Non -Fibrous 100% Material Page 2 of 13 kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 60216 Fax- 303-292-1451 www.metesting.com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services None Detected Cellulose Fiber 15% PROJECT: PLM16-570 Other Non -Fibrous 85% Homogeneous, Fine GrainediFibrous Lab -ID No. ........ Layer No. Asbestos Non -Asbestos LAYER 2 Sample ID Description Layer % Type (°lo} Components M PLM16-570-15 100% Grained Material 7615-120-CDW01- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15% 4 Drywall, White and Brown, 75% Other Non -Fibrous Other Non -Fibrous 85% LAYER 4 Homogeneous, Fine Grained/Fibrous Other Non -Fibrous 85% Material 5% LAYER 2 LAYER 2 None Detected LAYER 2 None Detected Material Mud, White, Homogeneous, Fine 10% 15% Other Non -Fibrous 100% 85% Grained Material LAYER 3 LAYER 3 None Detected Cellulose Fiber 99% Tape, White, Homogeneous, Fibrous 10% Other Non -Fibrous 1% LAYER 4 LAYER 4 None Detected Mud with Paint, White and Off White, 5% Other Non -Fibrous 100% Homogeneous, Fine Grained Material PLM16-570-16 7615-116-CDW01- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15% 5 Drywall, White and Brown, 75% Other Non -Fibrous 85% Homogeneous, Fine GrainediFibrous Material LAYER 2 LAYER 2 None Detected Cellulose Fiber 15% Mud, White, Homogeneous, Fine 10% Other Non -Fibrous 100% Grained Material LAYER 3 LAYER 3 None Detected Cellulose Fiber 99% Tape, White, Homogeneous, Fibrous 1o% None Detected Other Non -Fibrous 1% LAYER 4 LAYER 4 None Detected Other Non -Fibrous 85% Mud with Paint, White and Blue, 5% Other Non -Fibrous 100% Homogeneous, Fine Grained LAYER 2 None Detected Material 15% PLM16-570-17 7615-106-CDW01- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15°1 6 Drywall, White and Brown, 85% Other Non -Fibrous 85% Homogeneous, Fine Grained/Fibrous Material LAYER 2 LAYER 2 None Detected Cellulose Fiber 15% Mud with Paint, White and Blue, 15% Other Non -Fibrous 85% Homogeneous, Fine Grained Material LM16-570-18 7615-122-CDW01- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15% 7 Drywall, White and Brown, 85% Other Non -Fibrous 85% Homogeneous, Fine Grained/Fibrous Material LAYER 2 LAYER 2 None Detected Cellulose Fiber 15% Mud with Paint, White and Gray, 15% Other Non -Fibrous 85% Homogeneous, Fine Grained Material Page 3 of 13 kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver. CO 80216 Fax: 303-292-1451 www. m etesting.com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM 16-570 Lab -ID No. LAYER 1 None Detected Layer No. Asbestos Non -Asbestos 85% Sample ID Description Layer % Type M Components M PLM16-570-19 LAYER 2 None Detected Cellulose Fiber 15% Mud with Paint, White and Gray, 15% 7615-127-CDW01- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15% 8 Drywall, White and Brown, 85% .... Other Non -Fibrous 85% Homogeneous, Fine Grained/Fibrous Yellow, Non-homogeneous, 100% Material 100% Resinous/Fine Grained LAYER 2 LAYER 2 None Detected Cellulose Fiber 15% Mud with Paint, White and Gray, 15% Other Non -Fibrous 85% Homogeneous, Fine Grained Material PLM16-570-20 7615-123-CDW01- LAYER 1 LAYER 1 None Detected Cellulose Fiber 15% 9 Drywall, White and Brown, 85% Other Non -Fibrous 85% Homogeneous, Fine Grained/Fibrous 50% Material LAYER 2 LAYER 2 None Detected Cellulose Fiber 15% Mud with Paint, White and Gray, 15% Other Non -Fibrous 85% Homogeneous, Fine Grained Material _ ..� _.. __... .._... PLM16-570-21 —_ ... _.__._. _ _.. ... .... 7615-122-FLC01-1 Compound and Adhesive, White and LAYER 1 None Detected Yellow, Non-homogeneous, 100% Other Non -Fibrous 100% Resinous/Fine Grained Material PLM16-570-22 7615-126-FLC01-2 LAYER 1 LAYER 1 Compound, White, Non- 50% homogeneous, Fine Grained LAYER 2 LAYER 2 Compound with Adhesive, Gray and 50% Yellow, Non-homogeneous, Fine Grained/Resinous PLM16-570-23 7615-127-FLC01-3 LAYER 1 LAYER 1 Compound, White, Non- 50% homogeneous, Fine Grained LAYER 2 LAYER 2 Compound with Adhesive, Gray and 50% Yellow, Non-homogeneous, Fine Grained/Resinous None Detected None Detected None Detected None Detected Other Non -Fibrous Material Other Non -Fibrous Material Other Non -Fibrous Material Other Non -Fibrous Material 100% 100% 100% 100% Page 4 of 13 kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 waww.metesting.com info@rnetesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services None Detected PROJECT: PLM16-570 Other Non -Fibrous Other Non -Fibrous 100%n Homogeneous, Fine Grained Lab-lD No. Layer No Asbestos Non -Asbestos LAYER 2 Sample ID Description Layer % Type M Components M PLM 16-570-24 98% homogeneous, Resinous None Detected Cellulose Fiber Material 7615-100-FTC01-1 LAYER 1 LAYER 1 None Detected 40% Homogeneous, Fibrous Floor Tile, Orange, Homogeneous, Compound, Off White, 45%" Other Non -Fibrous Other Non -Fibrous 100% Homogeneous, Fine Grained Material 7615-110-FTC04-1 LAYER 1 Material LAYER 4 None Detected LAYER 2 LAYER 2 None Detected Cellulose Fiber 2% Other Non -Fibrous Adhesive, Yellow and Black, Non- 5% Other Non -Fibrous 98% Grained/Resinous homogeneous, Resinous Material Material LAYER 2 LAYER 2 LAYER 3 LAYER 3 None Detected Floor Tile, Gray and Blue, 80% Floor Tile, Red, Homogeneous, Hard 45% Other Non -Fibrous 100% LAYER 4 LAYER 4 None Detected Material Adhesive, Yellow, Homogeneous. 5% Other Non -Fibrous 100% 5 of 13 Resinous Material PLM 16-570-25 7615-100-FTCO2-1 LAYER 1 LAYER 1 None Detected Compound, Off White, 45% Other Non -Fibrous Other Non -Fibrous 100%n Homogeneous, Fine Grained None Detected Material Adhesive, Clear, Homogeneous, LAYER 2 LAYER 2 None Detected Cellulose Fiber 2% Adhesive, Yellow and Black, Non- 5% Material Other Non -Fibrous 98% homogeneous, Resinous None Detected Cellulose Fiber Material Fibrous Material, Off White, LAYER 3 LAYER 3 None Detected 40% Homogeneous, Fibrous Floor Tile, Orange, Homogeneous, 45% Material Other Non -Fibrous 100% Hard Material 7615-110-FTC04-1 LAYER 1 LAYER 4 LAYER 4 None Detected Compound with Adhesive, Yellow and Adhesive, Yellow, Homogeneous, 5% Other Non -Fibrous 100% Resinous Other Non -Fibrous Material Grained/Resinous PLM 16-570-26 7615-104-FTC03-1 LAYER 1 LAYER 1 None Detected Floor Tile, Tan, Homogeneous, Hard 80% Other Non -Fibrous 100% LAYER 2 LAYER 2 None Detected Adhesive, Clear, Homogeneous, 2%Q Other Non -Fibrous 100% Resinous Material LAYER 3 LAYER 3 None Detected Cellulose Fiber 60% Fibrous Material, Off White, 18% Other Non -Fibrous 40% Homogeneous, Fibrous Material PLM16-570-27 7615-110-FTC04-1 LAYER 1 LAYER 1 None Detected Compound with Adhesive, Yellow and 20% White, Non-homogeneous, Fine Other Non -Fibrous 100% Grained/Resinous Material LAYER 2 LAYER 2 None Detected Floor Tile, Gray and Blue, 80% Homogeneous, Hard Other Non -Fibrous 100% Material Page 5 of 13 kwT4River North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 60216 Fax: 303-292-1451 ww,,v.m ete sting. com info@metesting,com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -113 No. Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type M Components PLM 16-570-28 7615-111 -FTC04-2 LAYER 1 LAYER 1 None Detected Adhesive, Yellow, Homogeneous, 2% Other Non -Fibrous Resinous Material LAYER 2 LAYER 2 None Detected Floor Tile, Gray and Blue, 98% Other Non -Fibrous Homogeneous, Hard Material PLM 16-570-29 7615-114-FTC04-3 LAYER 1 LAYER 1 Adhesive, Yellow, Homogeneous, 2% Resinous LAYER 2 LAYER 2 Floor Tile, Gray and Blue, 98% Homogeneous, Hard PLM16-570-30 7615-118-FTC05-1 LAYER 1 LAYER 1 Compound and Adhesive, White and 5% Yellow, Non-homogeneous, Fine 100% Grained/Resinous Material LAYER 2 LAYER 2 Floor Tile, Green, Homogeneous, 95% Hard Other Non -Fibrous PLM 16-570-31 7615-121-FTC06-1 LAYER I LAYER I Compound and Adhesive, White and 5% Yellow, Non-homogeneous, Fine 100% Grained/Resinous Material LAYER 2 LAYER 2 Floor Tile, Green, Homogeneous, 95% Hard Other Non -Fibrous PLM 16-570-32 7615-125-FTC07-1 LAYER 1 LAYER 1 Adhesive, Yellow, Homogeneous, 2% Resinous LAYER 2 LAYER 2 Floor Tile, Gray and Black, 984' Homogeneous, Hard M 100% 100% None Detected Other Non -Fibrous 100% Material None Detected Other Non -Fibrous 100% Material None Detected Other Non -Fibrous 100% Material None Detected Other Non -Fibrous 100% Material .... . . .... . ..... None Detected Other Non -Fibrous 100% Material None Detected Other Non -Fibrous 100% Material None Detected Other Non -Fibrous 100% Material None Detected Other Non -Fibrous 100% Material Page 6 of 13 River North Environmental Testing, Inc. � 50Che�omP�e 303-297-0079kw4T Denver. CO 80216 Fax: 303-292-1451 *�vw.metoodng,cum in[v@meteyonQcnm REPORT OFTEST RESULTS PLM Bulk Asbestos Analysis N\A'APLab Code 20O440'0 CLIENT: Family Environmental Compliance Services PROJECT: PLM 16-570 Lab�ONc` --- �oy�rNo. Asbestos Non -Asbestos Sample ID Description _Layer% Type <�4 Components (�&} pLK818'570'33 7815'12O-FTC07-2LAYER 1 LAYER None Detected Adhesive, Yellow, Homogeneous, zw omarwvnF/umvs /uo% Resinous - wwto,im LAYER LAYER None Detected Floor Tile, Gray and Black, omrrwonpiun»us 100% Homogeneous, Manj Non- Fibrous PL�18-5�O'34 ------------' ---- ----_- rO15-127-FTCO7-3 LAYER 1 LAYER 1 None Detected Adhesive, Yellow, Homogeneous, em Omo,wvn'r/uvooa 100% Resinous Material LAYER LAYER None Detected Floor Tile, Gray and Black, om�rwo"piumus 100% Homogeneous, Mand Non- Fibrous �'��������� PLM1O'5��-35 --- 7615-100-L|PV1'1 Ceiling Tile, Brown and White, LAYER None Detected Cellulose Fiber 40m Homognneoue, Fibrous 100% Fibrous Glass uo% omerwun'Fwmvo 40m ma,o,/u/ P_M—~... 7615-118-L|P01'2 Ceiling Tile, Brown and White, LAYER I None Detected Cellulose Fiber *um .""'."y==""s. ruxvux 100m Fibrous Glass 00% omomon'numvs 40m mawn*/ pL�1O-�70'37 ----------- --------��--'-------- 7815-121-L|P01'3 Ceiling Tile, Brown and White, LAYER None Detected Cellulose Fiber *om Homogeneous, Fibrous 100% Fibrous Glass zn% Omp,wnn'pimvvx 40% wote,/a/ pLM70-570'38 - -�- -------__ 7815-104-L(P021 Ceiling Tile, Brown and White, LAYER None Detected Fibrous Glass 30m Homogeneous, Fibrous 100m Cellulose Fiber 40% 0mvrwun'piumvv 30% Material � �������... � PLM16-570'38 7015'118-L|P022 Ceiling Tile, Brown and White, LAYER None Detected Fibrous Glass 30% Homoqenoouo, Fibrous 100% Cellulose Fiber *o% ome,woo'pi»mvo 30% Material Puow 7 of 13 kTRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 w4 Denver, CO 80216 Fax: 303-292-1451 www. m etesting. com info@metesting. com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. Sample ID Description PLM 16-570-40 7615-121-LIP02-3 Ceiling Tile, Brown and White, Homogeneous, Fibrous Layer No. Asbestos Non -Asbestos v Layer % Type M Components (%) LAYER 1 100% LM 16-570-41 7615-119-LIP03-1 Ceiling Tile, Brown and White, LAYER 1 Homogeneous, Fibrous 100% PLM 16-570-42 7615-121-LIP03-2 Ceiling Tile, Brown and White, LAYER 1 Homogeneous, Fibrous 100% LM 16-570-43 ...... 7615-121-LIP03-3 Ceiling Tile, Brown and White, LAYER 1 Homogeneous, Fibrous 100% PLM16-570-44 7615-106-LIP04-1 Lay -in Ceiling Panel, Off White, Brown. LAYER 1 None Detected and White, Homogeneous, Fine Grained/Fibrous _._............. _...._—...�..-..._... 100% PLM 16-570-45 Cellulose Fiber —— 7615-106-LIP04-2 Lay -in Ceiling Panel, Off White, Brown, LAYER 1 and White, Homogeneous, Fine 100% None Detected Grained/Fibrous 30% PLM16-570-46 __ ..._._. �- 40% 7615-106-LIP04-3 Lay -in Ceiling Panel, Off White, Brown, LAYER 1 and White, Homogeneous, Fine 100% None Detected Grained/Fibrous 30% PLM 16-570-47 Cellulose Fiber 40% 7615-122-LIP05-1 Ceiling Tile, Brown and White, LAYER 1 Homogeneous, Fibrous 100% None Detected Fibrous Glass 30% Cellulose Fiber 40% Other Non -Fibrous 30% Material None Detected Fibrous Glass 30% Cellulose Fiber 40% Other Non -Fibrous 30% Material None Detected Fibrous Glass 30% Cellulose Fiber 40% Other Non -Fibrous 30% Material None Detected Fibrous Glass 30% Cellulose Fiber 40% Other Non -Fibrous 30% Material None Detected Cellulose Fiber 10% Fibrous Glass 2% Other Non -Fibrous 88% None Detected Cellulose Fiber 10% Fibrous Glass 2% Other Non -Fibrous 88% None Detected Cellulose Fiber 10% Fibrous Glass 2% Other Non -Fibrous 88% None Detected Cellulose Fiber 40% Fibrous Glass 30% Other Non -Fibrous 30% Material Page 8 of 13 River Horth Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 *WT4 Denver, CO 80216 Fax: 303-292-1451 www.metesting.com info@melesting. corn REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. Sample ID Description PLM 16-570-48 7615-127-LIP05-2 Ceiling Tile, Brown and White, Homogeneous, Fibrous Layer No. Asbestos Layer % Type LAYER 1 100% PLM16-570-49 -- 7615-123-LIP05-3 Ceiling Tile, Brown and White, LAYER 1 Homogeneous, Fibrous 100% PLM16-570-50 7615-122-MA01-1 Mastic, Brown, Homogeneous, LAYER 1 Resinous 100% PLM16-570-51 7615-105-SVF01-1 LAYER 1 LAYER 1 Adhesive, Black and Yellow, Non- 10% homogeneous, Resinous 30% LAYER 2 LAYER 2 Sheet Flooring, Off White and Gray, 90% Homogeneous, Semi -Fibrous PLM16-570-52 7615-104-SVF01-2 Sheet Flooring, Off White and Gray, LAYER 1 Homogeneous, Semi -Fibrous 100% PLM16-570-53 7615-115-SVF01-3 LAYER 1 LAYER 1 Adhesive, Yellow, Homogeneous, 10% Resinous 30% LAYER 2 LAYER 2 Sheet Flooring, Off White and Gray, 90% Homogeneous, Semi -Fibrous PLM 16-570-54 7615-117-SVF01-4 LAYER 1 LAYER 1 Adhesive, Yellow, Homogeneous, 10% Resinous 30% LAYER 2 LAYER 2 Sheet Flooring, Off White and Gray, 90% Homogeneous, Semi -Fibrous Non -Asbestos M Components M None Detected Cellulose Fiber 40% 5% Fibrous Glass 30% Material Other Non -Fibrous 30% 100% Material None Detected Cellulose Fiber 40% 5% Fibrous Glass 30°7 Other Non -Fibrous 30% Material None Detected Other Non -Fibrous 100% None Detected Other Non -Fibrous 100% Material None Detected Cellulose Fiber 35% Fibrous Glass 5% Other Non -Fibrous 60% None Detected None Detected None Detected None Detected None Detected Cellulose Fiber 35% Fibrous Glass 5% Other Non -Fibrous 60% Material Other Non -Fibrous 100% Material Cellulose Fiber 35% Fibrous Glass 5% Other Non -Fibrous 60% Other Non -Fibrous Material Cellulose Fiber Fibrous Glass Other Non -Fibrous ._............._....__ ... 100`70 35% 5% 60% Page 9 of 13 kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0075 Denver, CO 80216 Fax: 303-292-1451 www.metesting,com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services None Detected Cellulose Fiber 900% PROJECT: PLM16-570 Fibrous Glass 5% homogeneous, Fibrous Lab -ID No. Layer No. Asbestos Non -Asbestos LAYER 2 Sample ID Description Layer % Type {%} Components PLM 16-570-55 100% Hard Material 7615-120-SVF02-1 LAYER 1 LAYER 1 None Detected None Detected Floor Tile, Off White, Homogeneous, 75% Other Non -Fibrous 100% Resinous Hard Material Material LAYER 4 LAYER 4 LAYER 2 LAYER 2 None Detected Sheet Flooring, Off White and Blue, 55% Sheet Flooring, White and Green, 10% Homogeneous, Resinous Other Non -Fibrous 100% Material Non-homogeneous, Resinous PLM16-570-57 Material LAYER 3 LAYER 3 None Detected Cellulose Fiber 20% Drywall, White and Brown, Adhesive, Brown and Yellow, Non- 5% Other Nan -Fibrous 100% homogeneous, Resinous Other Non -Fibrous 80% Material LAYER 4 LAYER 4 None Detected LAYER 2 None Detected Sheet Flooring, Off White and Blue, 10% 20% Other Non -Fibrous 100% Non-homogeneous, Resinous Material 100% PLM 16-570-56 7615-106-SVF02-2 LAYER 1 LAYER 1 None Detected Cellulose Fiber 900% Fibrous Backing, Off White, Non- 15% Fibrous Glass 5% homogeneous, Fibrous Other Non -Fibrous 5% LAYER 2 LAYER 2 None Detected Floor Tile, White, Homogeneous, 20% Other Non -Fibrous 100% Hard Material LAYER 3 LAYER 3 None Detected Adhesive, Yellow, Homogeneous, 10% Other Non -Fibrous 100% Resinous Material LAYER 4 LAYER 4 None Detected Sheet Flooring, Off White and Blue, 55% Other Non -Fibrous 100% Homogeneous, Resinous Material PLM16-570-57 ---- 7615-100-TS01-1 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20% Drywall, White and Brown, 80% Homogeneous, Fine Grained/Fibrous Other Non -Fibrous 80% Material LAYER 2 LAYER 2 None Detected Mud with Paint, White and Tan, 20% Homogeneous, Fine Grained Other Non -Fibrous 100% Material PLM 16-570-58 7615-105-TS01-2 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20% Drywall, White and Brown, 80% Other Non -Fibrous 80% Homogeneous, Fine Grained/Fibrous Material LAYER 2 LAYER 2 None Detected Mud with Paint, White and Tan, 20% Other Non -Fibrous 100% Homogeneous, Fine Grained Material Page 10 of 13 River North Environmental Testing, Inc. kw4r 3650 Chestnut Place 303-297-0079 Denver: CO 80216 Fax: 303-292-1451 rvevw.metesting.com infometesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. - - .. ____ _-_ Layer No. Asbestos Non -Asbestos Sample ID Description Layer % Type {°lo) Components M PLM 16-570-59 7615-104-TS01-3 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20% Drywall, White and Brown, 80% Homogeneous, Fine Grained/Fibrous Other Non -Fibrous Material 80% LAYER 2 LAYER 2 None Detected Mud with Paint, White and Blue, 20% Homogeneous, Fine Grained Other Non -Fibrous 100% Material PLM16-570-60 - 7615-103-TS01-4 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20% Drywall, While and Brown. 80% Homogeneous, Fine Grained/Fibrous Other Non -Fibrous 80°! Material LAYER 2 LAYER 2 None Detected Mud with Paint, White and Off White, 20% Homogeneous, Fine Grained Other Non -Fibrous 100% Material LM16-570-61— -- - . ____ __..._ ___ _ _ _ _.......... . — -- 7615-103-TS01-5 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20;'0 Drywall, White and Brown, 80% Homogeneous, Fine Grained/Fibrous Other Non -Fibrous 80% Material LAYER 2 LAYER 2 None Detected Mud with Paint, White and Brown, 20% Homogeneous, Fine Grained Other Non -Fibrous 100% Material PLM16-570-62 ---.... _ �._._._ .._.._ —...._ _ _._ 7615-122-TS01-6 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20% Drywall, White and Brown, 80% Homogeneous. Fine Grained/Fibrous Other Non -Fibrous 80% Material LAYER 2 LAYER 2 None Detected Mud with Paint, White, 20% Homogeneous, Fine Grained Other Non -Fibrous 100% Material PLM16-570-63 ---..— ........ _ _ 7615-127-TS01-7 LAYER 1 LAYER 1 None Detected Cellulose Fiber 20% Drywall, White and Brown, 80% Homogeneous, Fine Grained/Fibrous Other Non -Fibrous 80% Material LAYER 2 LAYER 2 None Detected Mud with Paint, White, 20% Homogeneous, Fine Grained Other Non -Fibrous 100% Material PLM 16-570-64 _...._ _ __ __ ._..__ . 7615-119-TS02-1 Drywall with Paint, White, Brown, and LAYER 1 None Detected Cellulose Fiber 20% Off White, Homogeneous, Fine 100% Grained/Fibrous Other Non -Fibrous 80% Material Page 11 of 13 River North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 *WT4 Donve�C38021G Fux� 303-292-1451 mvn*mmevung.com inhm@metw,wing,cnmn REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAPLab Code 20O448'O CLIENT: Family Environmental Compliance Services PROJECT: PLK416'570 __- ......... __-__' - Lab-ID No. Layer No. Asbestos Non-Asbestos ----�----- Sample DD Description LmyorY6 Type M Components M PLM16-57005 7615-120-TG02-2 Drywall with Paint, White, Brown, and LAvEn 1 None Detected Cellulose Fiber 20% Off White, HomoOoneous, Fine 100% om",wonpmmvn 80% Grained/Fibrous Material ............. ........ _......... PLw1f-57O�8 ------ �---- 7O15-118'T8O2-3 Drywall with Paint, White, Brown, and LAYER None [)elected Cellulose Fiber uo% Blue, Homognneouo, Fina 100% om*,wmnp/omvu on% Grained/Fibrous' Material ���..... ������� PLM16'570'67 ��--'--------------� -��------------ 7015'106-TG02-4 Drywall with Paint, White, Brown, and LAYER None Detected Cellulose Fiber zO% Blue, Homoganoouo, Fine 100% omcmonpmrovm 00% Grained/Fibrous Material PLM10-570-68 - -- ---'------'--� --- - 7015-123-T80-5 Drywall with Paint, White, Brown, and LAYER None Detected Cellulose Fiber 20% Gnay, Homogeneous, Fine 100% Other Non-Fibrous oO% Grained/Fibrous Material PLk416'570'08 7015-124qS03'6 Drywall with Pa/rv, White, Brown, and L^vsn 1 None Detected Cellulose Fiber 20% Green, Homngenonus. Fine 100% omo,wnnFmmuu nO% Grained/Fibrous Material �' PLM 18-57O-70 ------------ --- 7615-125-TS02-7 Drywall Dgowa||with Paint, White, Brown, and LAYER None Detected Cellulose Fiber zn% Green, Homogeneous, Fine 100% Other me,mon'pmmuo nom Material PLx415'570'71 �- -------------��---� 7615-106-UC01-1 Undercoating, Uodemna0nq.B|auk. Homogeneous, LAYER None Detected Resinous lou% omc,wvn'pimn"s 100% pLM10-570-72 --- — 7615'121'UC01-2 Undercoating, Black, Homogeneous, LAYER None Detected Resinous 100% Other Non-Fibrous 100% PLK81G'57U-73 � --�-------��� --------- --�� -�---- ----------'----��_ 7015'121-UC01'3 Undercoating, Black, Homogeneous, LAYER None Detected Resinous 100% Omer Non-Fibrous 100% paew 12 of 13 kw4TRiver North Environmental Testing, Inc. 3650 Chestnut Place 303-297-0079 Denver, CO 80216 Fax: 303-292-1451 www.metesting.com info@metesting.com REPORT OF TEST RESULTS PLM Bulk Asbestos Analysis NVLAP Lab Code 200448-0 CLIENT: Family Environmental Compliance Services PROJECT: PLM16-570 Lab -ID No. Sample ID Description Layer No. Asbestos Non -Asbestos Layer % Type M Components M -------- - -------- ADDITIONAL COMMENTS: All separable parts or layers (except paint) within the same sample are analyzed and reported individually. Composite asbestos percent is reported, if applicable, by visual estimation. ND = None Detected TR = Trace, less than 1.0% Analyst: 4'z/ Mai$ S64 Ur Tales Date: 12/28/2016 Page 13 of 13 Document No: FCF-04.00 Effective Date: 10/17/2013 1 Xg V I Page of River North Environmental Testing, Inc 3650 Chestnut Place , Denver, CO 80216 NziEi- T, Ph: 303-297-0079 * Fax: 303-292-1451 www,rnetesting.com - info@rnetesting.com Client; Family Environmental Compliance Services Contact: Jerome Hairston, Josh Sieger Address: 3650 Chestnut Place Denver, CO 80213 Phone #: 303-296-6022 Fax #/Email: Jhairst 1s�er Date Sampled: ------ 12/27/2016 Sample Location: 7615 W. 38th ave. Special Instructions: Lab ID -1 (for lab use only) Client ID Description Type of Analysis Volume/Other -100-BBA01-1 P LM 7615- 1 0 5 B B A 0 1 2 .............. . PL I M -- ------- 7615-104-SBAOI-3 ........... ......... ... PLM 7615 -119-BBA01-4 .......... �7615-.127-BBA01-5 PLM 6)(a 7615-1 0 0 CA 0 1 1 .. ............... 1 P . L . M 1---------.. 19-CAOI-2 . . I PLM ...... 7615-121-CA01-3 ............ ....... PLM ?!�-122-CA02-1 .. ......... PLM j 0- 7615-123-CA02-2 ........ ....... 7615-124-CA02-3PLM ............... . 7615-10..0...-..C...D.. WOI-1 ---' ' ,,-' ......... .......... CDW02 . .PLM ................... ............. ...... . .......... PLM .......... .............��i�-105 t t 7615 119 .C'DW01-3 .......... .................................................... ............... PLM ........................... 7615-120-6��61.4 .. ... ..........PLfu1.. ------ - . . ..... (7 7615-106-CDWO 1-6 7615-122-CDW01-7 �PLM ....... . ... PLM ........ 7615-127-CDW01-8 -I."..,..,..,,.,-..'....-..,..1,. . ..... .... PLM 7615-123-CDW01-9 --'— -1-1- PLM Total Number of Samples: Sample Condition (Accept/Reject): Requested Turnaround Time: (X) RUSH )Next Day ( ) 3-5 Days RUSH Turnaround 1 required Prior nolifiCation. Additional fees MaY 21PPIY. Call lab for more detaik Relinquished by: Date/Tirne: Received by: Date/Time: Relinquished by: C-1 z Date/Time: Received by: Date/Time: Document No: FCF-04.00 Effective Date: 10/17/2013 Page _2_ of River North Environmental Testing, Inc L 3650 Chestnut Place * Denver, CO 80216 zr-AE- T, Ph: 303-297-0079 - Fax: 303-292-1451 M -t -44u www.rnetesting.com , info@rnetesting.com Client: Family Environmental Compliance Services Contact., Jerome Hairston, Josh Sieger Address: 3650 Chestnut Place Denver, CO 80213 Phone M 303-296-6022 Fax tt/Email: JhairsLon P=-lamilvenvironmenta, _,Cory" 7s! ier�tamifyenvironentai,com Date Sampled: 12/27/2016 Sample Location: 7615 W. 38th Ave. Special Instructions: Lab ID (for lab use only) Client ID Description Type of Analysis Volume/Other 7615-122-FLCOI-1 - .............. .......... ... ........... PLM 7615.-.12.6-.FLS0.1-2 . ....... ........... ...... ............ .......... .... .........PLM PLM ..... . .... ZL/ ...... ........ .. . .. 76 1 5 -1 oo-Frco l- i ...... I ............ . ...... ....... . ...... ............. PLM ....... ........ ``j .............. .......... .... 7615-100-FTCO2-1 .. . ............ ........... ..................... ........ ........-..-.. .......... .......... . ... .............Z.. ...... ........... ........... ............. ...04-FTC03-1 _7 7615-110-FTC04-1 .............. ............... PLM .. - .. . ........ .......... . ....... 111-FTC04-2 ......... .... ........... .......... .............. PLM ................. -114-FTC04-3 ............................ ........... ............. ........ PLM ........ . .. 7615-118-FTC05-1 .......... ...... ........... .......... .. PLM ......... 7615-121-FTC6-1 .................... PLM.......... ............. . ......... . .... ..... .. ...... .... ............. ....... . ......... ........ ................ ............................ .......................... . - �,73 ......... . 7615-126-FTC07-2 ............... 'PLM .11.1.1 PLM ............. 7615-127-FTC07-3 . ........ ............ .............. PLM .............. ..... .. 7615-100-LIP01-1 ........................ - .. . ........ . . ........ PLM L.P ........ . ...... ....... . ........ PLM ....... 21,UP01-3 ........ PLM ........... . 7615-104-LIP02-1 .............. ........... P LM ...... . ........ .......... ............... ................. 7615.119 -L IPO 2 2 ...... . . ...... PLM ..................................................... 7615 121 LIP02-3 PLM Total Number of Samples: -P It-LFVI Sample Condition (Accept/Reject):_ZZ7- Requested Turnaround Time: (X) RUSH *** ( )Next Day ( ) 3-5 Days RUSH Turnaround times required prior notification. Additional fees may apply, Call lab for more details. Relinquished by: C" Received by Date/Time: q 7 Relinquished by: Date/Time: Received by: Date/Time: Document No: FCF-04.00 Effective Date: 10/17/2013 Client: Family Environmental Compliance Services Address. 3650 Chestnut Place Denver, CO, 80213 Phone #, 303-296-6022 Date Sampled: '? 6 1 C� '� 0" Alt -- Sample Location: Special instructions: r l ;�;��, S 7G Page -a Of --4— River North Environmental Testing, Inc 3650 Chestnut Place * Denver, CO 80216 Ph: 303-297-0079 a Fax: 303-292-1451 www,rnetesting.com o info@rnetesting.com Contact: Jerome Hairston, Josh Sieger Fax ##/Email, Jh,airston(162'bfamAygfly!rtrnmentai cr�n3 1s ulg-r Lab ID (for tab use only) Client ID Description Type of Analysis Volume/Other -.L..I..P..03-2 PLM -......---........... Ziiai.zPbii .7..6...1. .5..-..1--2 ..1.. -- ......... ............................ .. ........... ................. ....... ... ......... 7615-106-LIP04-1 ... --- ..... ........ -PLM PLM q� ......... . . .................. ......... 7615-106-LIP04-2 ...... .......... . .... .......... ...... PLM .... q1. ....... .......... ...... . PLM ... ................ ........... ........................................... - .7 7615-122-LIPOS-1 ................. .. ........... ......... _.q ............ 7�i�:i'�7-LIP05-2 ...... . .......... .............. ......... . .... ...... -PLM .......... ............... PLM Lj4J . ..... i6l5,-*123-,L,I,PO5,-3 PLM ........... -& -122 -MAOI -1 .................................. . - -1.-.-.--. ......7615 PLM .............. ..... ..... 'V' PLM ......... 5 �, .... . . 7 6 15 - F-0"-1-'-* *2"* .... I. . ....... .......... ...... ........ FLM . ...... ... .... .............. 11 . . ..... 7615-115-SVF01-3 . . ...... ....................... . .. - ........ PLM .............. .... . ..... <;LJ ........... 761.5-111.7-SWO1.-.4-1 ................. ... . ...... ............ ............ 7615 -120-SVF 0 2-1 .............. - ............... .. .... .PLM ..... ........ ............. ... PLM ....... . ............ -10&SVF02-2 .......................... . . ...... . ...... ........... . .. ...........I.-...... ........... ...... ...... . ..... -.-PLM PLM ......7615-100-TS01-1 ..... ...................................•.... -105-TS01-2 ........... ............ . ..... . ... PLM ............... . . ..... 7�1�-104-TS01-3 ............. .. ............ ............ I ........... PLM .......... ..... ...... ..... --- ........ . . ............. 7615-103-TS01-5 . ......... ......................... ............. PLM ..... q 7 - u 2- c Ir" -73- IFLIMI I Total Number of Samples: Sample Condition (Accept/Reject): Requested Turnaround Time: (X) RUSH )Next Day O 3-5 Days RUSH Turnaround times required Prior notification. Additional fees may apply. Call lab for more details. Relinquished by, Received by: Dateme: O 4,- Date/Time: Relinquished by: Date/Time: Received by: .. ........ Date/Fime: Document No: FCF-04.00 Effective Date: 10/17/2013 Page 4— of River North Environmental Testing, Inc 3650 Chestnut Place * Denver, CO 80216 Ph: 303-297-0079 * Fax: 303-292-1451 www,rnetesting.com a info@rnetesting.com Client: Family Environmental Compliance Services Contact: Jerome Hairston, Josh Sieger Address: 3650 Chestnut Place Denver, CO 80213 Phone #: 303-296-6022 Fax #/Email: JhairsL—Iln-Ef—amilyenvironmentalconn-i ILI cher@famtyenvironmental.com Date Sampled: 12/27/2016 Sample Location: 7615 W 38TH AVE Special Instructions: Lab ID (for lab use only) Client ID Description Type of Analysis Volume/Other 6i—&J . ........ 7615-127-TSOI-7 ...... ........... 7615-119-TS02-1 ... . ........... - ................ . . ...... ................ —PLM ........... .... . .. . ... ...... ......... .... ....-120-TS02-2 ............ . . PLM ... ... . .. 7615**H6'ii6j�� .......... - ............... ........ ...... ............... . ................ -- ........... PLM ............... .......... .......... 7615-106-TS02-4 .......... .. . . ..... ......................................................................... ........... ............ 7615-123-TS02-5 .............. .............. PLM . ........ ....... 4 ...... 7615-124-TS02-6 ................ . I- ... . . ..... - ...... -- .... .......... ........ PLM .............. ....... 7615 . . ............... ................... .. . .... ..................................................... .......... .. J-- __ . . ........... ............ -121-UCOI-2 -- - -- ......................... . . ..... ............. PLM ................................... ...... .......... .......... .......... 761S-121-UC01-3 ..... . ............. ............. .... .... ....... ........... ............. ............ --...PLM ........... .......... ...... ............ -- ........ ........... . ..... ......... -- ............... ....... ............ ...... - .... - ........ !I ...... .. .... ........... ........ ........... ... - -- ...... ............... . . ............. ...... ....... ........... ...... .... ..... . ............ ...... ............... ........... ....... .......... ------------ .................. . ... ......... ................... ............ ........ ....... .................. ..... ..... . . ...... ................ --- ..... . ......... Total Number of Samples: -7 Sample Condition (Accept/Reject): Requested Turnaround Time: (X) RUSH )Next Day 3-5 Days RUSH turnaround limes required prior notification. Additional fees may apply, call 13b for more details. Relinquished by: Date/rime: Received by: Date/Time: Relinquished by: Date/Time: Received by: Date/Time: 36 0 Chestnut Place, Denver, Colorado 80216 J CDi � 2 . Phone. 30�._96.60�2 /Fax. 303.292.1451 APPENDIX D INSPECTOR CERTIFICATIONS r k' N 1 w t R ! of Public ? andEnvironment ASBESTOS This certifies that Josh Sieger Certification No.: 10744 has met the requirements of2S--507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part B, and is hereby certified by the state of Colorado in the followinp d i i n1 i b. yd {{ A uil+di Inspector* «3 a4 Issued: August 10, 2016 Expires.. August 10, 2017 h. �x " This centricate is valld ren%, with the Passession of a art Di sign -approve l ovining course cerdfleation In the ittsdpline sperifted above, 4 .SEAL T � F E t e 3 n b rt () K (D (D O h a K O Cr M "a 0 ~ M a O O (D n � n K G a 0 H p N- O O M M nM Y W (D M w i'• a H p �EDo V m n K O n 0 n a b � H • (D nm O H K r n (D (D 0 �aCD m a N : O n (D M H o[o H (D (D H O P)!� M o (D b O N n N a W K N• K O K n j w b H a m x a � Y• m a Y. m n n < m m a n o v M H m Y m ti n a w n w m a r a E 0 m O y N O M M d Y• R V 0 x m m �n R rt � O R m 7 M n m h V G ma� w P M m a m E n O 0 n a m �m y n y n n K p m vB a a n H• O O R h d � R n a' P � m M L m M m m R w v m rt O 0 Y O m a m m w m m m a m w M n Y. m b m a w v pn �• P P m V• N y r' p. q o n w a n m o � rt M� ID m h m M m w m rt m m M a rt •- m m o< m m x F-3 Ul H O d0 n N o �D 0x O� O W < W 00 O O H ro n N - r7 N O H rn O d w I n b rt () K (D (D O h a K O Cr M "a 0 ~ M a O O (D n � n K G a 0 H p N- O O M M nM Y W (D M w i'• a H p �EDo V m n K O n 0 n a b � H • (D nm O H K r n (D (D 0 �aCD m a N : O n (D M H o[o H (D (D H O P)!� M o (D b O N n N a W K N• K O K n j w b H a m x a � Y• m a Y. m n n < m m a n o v M H m Y m ti n a w n w m a r a E 0 m O y N O M M d Y• R V 0 x m m �n R rt � O R m 7 M n m h V G ma� w P M m a m E n O 0 n a m �m y n y n n K p m vB a a n H• O O R h d � R n a' P � m M L m M m m R w v m rt O 0 Y O m a m m w m m m a m w M n Y. m b m a w v pn �• P P m V• N y r' p. q o n w a n m o � rt M� ID m h m M m w m rt m m M a rt •- m m o< m m x F-3 Ul H O d0 n N o �D 0x O� O W < W 00 O O H ro n N - r7 N O H rn O d w I 40 Agpad-syl BALANCE REPORT Double T Balancing Company 6093 S Quebec St Suite 201 Centennial, CO 80111 aw • and Balance Date.- w. Denver Heating & Air Conditioning 1900 W. Hamilton Place O 80110 FACILIBUILD www.fadIibuiu� a Double Balancing Company s Iwo T VOMO ».. 15 FAN -S<» d FAN - Exha< 27 Powered y Fod#Wtdl Date: 427=16 Page 2 of 28 www.6clUbufld.com y: .> Double T Balancing Compan \ \ ftajmt. \ \ - IOUCHS70M : \EAT FUDGE \ \ ftw*md by FOOMMI Date: 4W=16 Page 3o2» wa ?? <c< Double T Balancing • i. e .. .. :; _ Mi ^ W Mt r •.; s r RSP, � by l! 4,27=1 6 Pap 4 of 28 www.UdWjtdtd.ccwn Powered by l Date: 4/2712016 Page 5 of 28 www.fkMbuild.corn Balancing Co Double T wWAGING Asset RTU2 AREA: Date:V27/2016 Page 6 of 28 C Double *t + arr. • ftmrWtWFM*&Wl Datw. 4/27/2016 Page Sof 28 www.facftuild.com Double \}b\e T Balancing Compan f : « 12376. MICHSM&:«« »2 <r« d m Date: 4n7M16 Page ?»28 www.fadbWW.com Double Balancing Company AHU/RTU a ^: Datw. M27/2016 Page 9 of 28 Double Balancing TOUCHSTONE y Short on 04127=16 Powemd FMOBWidl Datw 2www.fadlbuild.com Double Balancing Company ft �.TOUCHSTONE PoweredbyFoaModdl Date: 4127/2016 Page 11 of 28 www.f4dkbuild.com w eted By. Ardhony StXxt on 04 127)2016 of _ . Powred by %d w2! Date: 4/27\)a . .»32:28 wwwJ4dlJbuHd.ccwn Do,uble, /TBalancing Company, + M 12376-TOUCH61VWIA «G- «»«6+52 :w «1. 9 I'm,w wc 4« Po©dby ©W °,t 4748 Page 13 of 2 ` ?.Ad \ 4:w aft uouble T Balancing Company TOUCHSTONE Powwed y FbaiSaWl Date: 4/27/2016 Page 14 of 28 www.facdww.com Powered by # " ! 1r3 4(27/2016 Pa96 IS of 28 www.fadlibWW.com . Duct Design ACtual V4kW' 28.25 fi m 2 S Hoot 14 ; 1 FPM: 52 FPM: 56 Area Z75 CFM: 142 CFM- 154 R.: Oubkle Air CFM Duct Traverse Daft Points Powered by # " ! 1r3 4(27/2016 Pa96 IS of 28 www.fadlibWW.com rr ar Double T Balancing Company prolgot J=n - MXMM& M40t,* - WWAT MM�� r► ur A Duet Wift,6 i Hekjht 14 ReadkW 1 .75 .P.: Temp Outside Air CFM Duet Tmvem Deft Points Factor Design SCFW. SUM. 6 FPM: 28 CFM: 76 CFM: 77 *i 1 1 `P ♦ . t" .IGHE=FMH- *. it I i Aftftude: Density. um FadOWIdl 4127/2016 Page 17 of 28 www.facflibuikLcom Double T Balancing Company fto*t. 12376 TOUCMONE WAGING - WHEAT FKWIE " ®► Rocftrqutw Duct Tmwee ftpwt Service: A a Duct Design Actual Wicift 28.25 Readnq& 14 1 FPM: 53 FPM: 56 Arew 2.75 . 147 154 S.P.: Powered by f 16 Page 18 of 28 wwwfadfibuiW.corn Double T cing Company project: 12376 - T. Rectarexter Duct Traverse, Report s: Factor Duct Design Wkfth. 2825 Readings: 2 SCM S Height 14 :1 : 98 FPM: 104 2.75 4 269 CFM: 286 .P.: Outskle Air CFM Duct Twerse Deft Points Date: 4)27/2016 Powered Fit .I www.facVIbu#d.oDm Double «^ Balancing Company ±ate » 23 - TOUC"STONEl««OI««+« RM Syste lnft.- d - Supp}? »?«. ReWExhƒ a) .. . : . . ; <<:; AaMmy« » on QWrM6 <' ©»<»b �4: ! Dte: 4/27M1 6 Page 21 of28 » w. a « Double, Salancing Company ±.* » 12376 - TOUCHSTONE WAGING <»«» »++2 System FAN d Supply C*mpWWB._ Arthorwy ShortOVUM 2:.* y:<» ^.:»(»«) . Compkited y Antitorvy Short on 04027=16 ��. y� . ». . ..... . �.... �..... ... �. .��.. . Date: 4127/9016 Double �o \§b \e T Balancing Company ± » IUM - TOUMMOM:«x«: e«s» M FAN \<*pl» « »2!©<ty<. «#.w«7 as RxN&MI «. « 7 O16 . Page 23 of 28 www.facithAtd.com uouble T Balancing Company ±.* » IZIWI. M"STONIE IMACONG. EAT R ?? S ste FAN w Supply CornpletedBy.ArM w Short on 04/27/2016 Notes Oub ¥ design 60 C©K} actual 65 CFM. R\22<<2. M. Double �o \\b \e T Balancing Company Pr*Oft IUM MX ?«+»E MAUNG m>»<« »f«2 «:*»mom FAN w Supply DWUM Supply (GD) . Coff~ fW.»y:7»:»w04aWMO: Po"redhyfWft&NdI Date: ..7r 16 ;Page256 28 www.fad4btdW.cofn � ar Conq*ftd Br. AnV" Short on O Amwed by F F ' :► Date:www.facftu#d.coin Double T BalancingCompany TOUCHST014E :" X16 DWusw x Corr~ Sr. An#" Short an 04MVA16 Double. ^^ Balancing Company 6ft-><2 . TOLMHOOME IMAGM - WHEAT »Dm SystenWnit.- FAN - Exhaust 2\BY: .moy: rA . Double Balancing Company Description •r it- x • a s nyl. - Sp it System Air Handling Unit i, rss Atmosphere Blower CoilManufacturer Brake*• . _ , Air Unit Ceiling Diffuser e Unit �Cubic Feet 77 .. Center Line "' ' • r Room Air Conditioner Cabinet Unit Heater Not Given r *, . le . "Iwo Evaporative Cooler Pump haust # J����I nper Square InchElectric Heat * 1 IIReliefHood- unnin.. Fume Hood ' • otation per Minute «. Powered Box !Roof Top Feet r vt w �'Fan Powered Variable Air Volume Feet s r Feet of Head .� �Furnace s "Gallons per ► _; Heat Pump Heat Exchanger r Horse Power iw a� ��va . t - Air Volume Lead Lined Drywall I Lead Lined Sheetrock I Lead Lined Gypsum Board Lead Lined Dry... Pagel cif3 * � 0 rotection Prnma# # I kt&A, VIEW C&PIIQ QJ ILNQ&� 1\ * FOR LEAD LINED DRYWALL. _QS '(J-M�Jr�T LS L L"d Rwk-ed G)w= Bmd qw� RPP - 1,BG Lead Lined Drywall (also referred to as lead lined sheetrock or lead lined gypsum) is supplied with lead lining bonded to 1/2" or 5/8" drywall. Custom sizes for lead lined drywall are quoted upon request. We also provide lead lining bonded to specialty drywall such as moisture and mold resistant board. Lead Lined Drywall (lead lined sheetr-qAk-,LeAJJiueA 3/8" diameter lead discs. SHEETROCK, LEAD LINED GYPSUM WALLBOARD •) I If NO 11 Lw- IN 11*3 t The Lead Lined Drywall (lead lined sheetrock. lead lined t wall t?,&AAk*j ,11magon http://www.radiationproducts.com/gypsum-board.htm 2/3/2016 Lead Lined D"all I Lead Lined Sbeetrwk I Lead Lined Gypsurn Board Lad Lined Dry... Page 2 of 3 lead lined sum u I , - M plill IIIII�Iipim��'�I piim�pii�� K 1 1121, i I M; 11 1 ;:1 Click hem Lor Actails 1�)n cut-oql�AL AL Aenetratio I'll, ;" * i I 149 A low&.131 t I I L "p— r VVIDE STRIPS 0 V .w LFAI) LwD Gy D. O• K. Slim 0 Bt)..KXWS (SAME MITERMEDWE STUDS ThCMESS AS LEAD WALL DETAIL UNM) • Mold resistant wallboard • Impact resistant wallboard • Fire rated wallboard • And virtually all VSty, National Gypsum, Temple Inland and Georgia Pacific products � I I I � � I I � � � �as a I 1 11 11 1 I L— Us 1000 Superior Blvd, Suite 3 10, Wayzgga, minnesota 55391 Copyright 0 2016 Radiation Protection Prgi,41 I Ed—VjL:,v— Site Credits: L-crea 93Z http://www.radiationproducts.com/gypsurn-board.htm 2/3/22016 ffi* for Tbu ne TouchStDne Imaging Bel'inett hist supervisor PDF processed with Cut DF evaluation edition ww+ .QePDF-c m • � t 303432-8370 303-422-2680 Fax Waster Backfilow AssemblyBackt tt please print with BLOCK RING) ( Water Supplier: District. Meter .. Customer Name: touchstone imartino Facility Address: 7815 w.38th ave. unit 8113 City. wheat ELdff ST: Co alp;80033 Contact Person: fou buccino Phone: C i Make: wilkens Model: 975 XL2 Type of Use Protection Orientation Type: 0 RP Q DC El PVB 0 Air trap 0 Domestic 0 Containment Inlet Nutlet Size: X4' Date Installed. 0411512016 0 Fire 0 Glycol 11 Containment by Isolation Horizontal 0 New 1 Existing 0 irrigation Cl Isolation ® Vertical Up Previous Assembly #. 0 Recycled 0 Vertical Down 0 Location: mechanical room, Approve& Y 0 N 0 LineInitial Test Re -Test Results PSI: 70 Tightness Diff ential Repairs Tightness 'iDifferential .,._,. e..�. ..... ..�,.�.^-.�_,�....... . .. ... .... �.. .,�e�m,,.�r,., Check Valve ##'I 13 Leak Y 8 ..,m ....,.n_...� ..,.w ....... .. ..� �. �e._. .. .,.._..�.. _. ....fie ..� ., 0 Leak (RP, DC, PVB} Tight 0 Tight d,. ..w . .. .. .. ....... ..... "... .....0 r ,.. ...,,.. .... ,.„ ,..,.. >. Check Valve ##2 G1 Leak 7 „...... ..,, ., .,„ ...... ....., ,.. ,.., .. ,,...... ..,,, ...,,. v., , .. "........ ..... ...... .. ..«..0 ,a. 0 Leak (P DC) Tight ,...:..,.,..w ....... ... .. .. ..... ... ,,......,,,.,,.. ,.,..,.:,.. .,..,..,.., Cl Tight .. .,... , . a, Relief Valve 4.2 (RP) ,u.. �,.., ,, ...m. wo m ... :,o: .,.... .,...,M ... . . ...:....... .. ...... x.w . ............ .,. ..:..,, ,...,. ...n...�«. a o .,.,....,., ,......,.,, ., w �..„,..,� ... .... .. Suffer 7 (RP) .., ......... 3 i s t Air Inlet { a t (PVB) r Shutoff Valve #1: Tight Leaking Replaced Shutoff Valve ##2. Ti tit Leaki Re lae, Backpressure: 0 Yes 0 No Test Procedure: ® PA: ASSN; 'Commenu: Alarm Company/ Fire Department: DFS Certification . Person Notified. Contacted By. Turn Off Date/ Time: 1/1/1900 Turn On Date/ Time: 111/1900 Test Kit Make: midwest Model: 845 'i'' Serial ##» 03071821 Last Calibration Date: 0211012016 TestingCompany: fire inspection Tester Name:. chase Phone: 4 Sig tore» Ce to Nxpiratiran Date: 12431 18 Testing smliany: Submit by (preferred) to CrossOonnechonControf@denverwater.org, type *Badftw Test ReporW in the subject line OR submit by Fax to (303)794-8325 *FAALED test resufts must be is C to Denver Water within 24 hours of failure A s r a rs t r 1 ►�:�:a dir ' r ,rsa c k •�r�° it s ar ar � r.r �� s rr :� �► a � « eye � i� a • r - e r� ;ter tr :ar';.. i+"W"MU yr : i § � � 77 i i` # t....:. r l,......a«! !1) 1 i'.+n r i 9c.. r. www.Monroe-newell.corn 1400 Glenarm + Suite 101 * Denver, Colorado 80202 a • ! 623-6602 m WCHRISTOPHER MENGES ENGINEERING, INC. s � � Date 01-20-2016 ?'Tolect Touchstone Imaging, Wheat Ridge, GO — Plufting Subrnittals r► s• r ,. r r • a rr •r • r • rr a actionr r .s w r is s*W to ttle requirements*ns erd r wCft--&)nS- The cOf*vMOr �: responsUe for: dmensions, r • r >r � r♦ ,r .' • ♦ r x„ ... r r .w. e r rr w • r r e= r 01-20-2016 CHRISTOPHER lPHONE,t a: Lead Lined Dryxvall I Lead Lined Sheetrock I Lead Lined Gypsum Board Lead Lined Dry... Page 2 of 3 sheetrock, lead lined gypsum wallboard) kLBLt0r cLh details on cut-outs C—J1q-__----.--And Renetratigis., I 'i W , IZZAMP311#3 WmLsnw a troc, WIDECORNER SIFXL STUDS • Mold resistant wallboard • Impact resistant wallboard • Fire rated wallboard • And virtually all USG, National Gypsum, Temple Inland and Georgia Pacific products Contact Radiation Protection Products or request a quote, teal amore about our industrial leadnmiji Cts. !� �tiest �a� I Contact Lis 1000 Superior Blvd, Suite 3 10, Wayzata, Minnesota 55391 Cow rieht 0 2016 Radiation Protection►reserve& Sftgmap I tr_ivacy Llolicv I Site Credits: Ecreativeworks ... ......... http://www.radiationproducts.com/gypsum-board.htm 2/3/2016 City of Date. �'P`Wh6at le CommCiN i ii Li7P 4 Nt' Add to Pelmit ti' Building ins tiara %Division�Divisione 7500 W. 2e Ave,, Wheat Ridge, CO 80033 Office: 303-542865�*'F x: :,237-8929.,,% Inspection Line: 03-23415933 Email. emits ci.eatrd e.co,s Building Permit Revision/Amendment Application Address: City, Mate, Zi (if different than property address 0"RPM.* I 111111= ai m x j - dditional valuation•- all general • • a -• work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit + If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour• * (� i> 0 wl ,,-) -.50o 4) 7- d le Lc --, , 7- I'c> PCO'k ) z1 Sq. FULF Stu's Gallons Amps' Squares __ Other li N L= UJ ... w.: # Y� # w1F � w M ar "� M ff # 10 uP10, i#r • s s •. .#r rw a ew � # �. 10 • R ft# ► # � f # IIIF;. # »!� City of ©! : /�..... .......... �:.Review Fee: « w�r :■, < 2 4 « °\_, � /::<■t * � Address: t, State, Zip:� Complete all irma#B# on BOTH sides of this form It • �i y dp YY � � � � � � iF CGS TUN- a . FULF tu's Gallons Amps Squares, Other 0 • I 1111q, i E ;tris m m V%AhispeAA/a,ft at 23 feel, 0 Ili- 1 11 li: jj��Jpjlljlll 717NMIT-717 MImii I I'll a= ■ Em I-OlIpTi FOR OFFICE USE ONLY ` , City of ate: �� �- Building & Inspection Services Division 7500 W. 2e Ave.; Whet Midge, CO 80033 Plan Review Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 313-234-5+333 Building it Application Please'awnplete all highlighted4reas can bothsidesof thts may not b0prooessod. PropertiAddr fa$: Property Owner (please print): E M Phone: 3 va r r nor ,�me Mailing Address: (if different than property address) Address: 2q,, State, Zi Arch t rrglrr rE-mail: lilk Phone: contractor: Contractors City t. cen n : t S t Phone: Contractor E-maildress: Sub o et lectri l: Plumbing: Mechanical: W.F . City License # i R City License W.F . City License Other City Licensed Sub: Other City Licensed Sub; City License # City License Complete all information on BOTH sides of this form NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW ENTIAL STRUCTURE COMMERCIAL COMMERCIAL ! Y!! ,yam RESIDENTIAL Y SIR 7r 111 IIF ROOFING ! Y ADDITION WINDOW REPLACEMENT COMMERCIAL i 1.Ik STRUCTURE ,IM RESIDENTIAL 1 1NM STRUCTURE MECHANICAL i d M•Y REPAIR M Y• REPLACEMENT r•'. FI Y �PLLIMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL Y • • i REPAIR • Yalr • .111 y � d CEMENT ER r cr be) OTH iount of Materials to t>e used, etc.} p _ . �" t r , tLPCV4AL IS , 5q. UL _ Btu's Gallons 4 h t 0�` t t� tt ny FFttp� �t� l;lo, � *y 1 1 t r t i, �hgS } l S 6 I rimil 0 Wam w -Wow- R CIL, I m UJ V) UJ Do > 0 CL Lu z z t1►' CC Z) u J 0 0- z uj uj 0 Wam w -Wow- R CIL, I m r City of 6,: jd OR OFFICE USE ONLY Building & Inspection Services Division zC) 16 75001 W. 291' Ave., Whet Ridge, CO 80033 3 Plan Review Fee ,. Once. 3013-235-2355 Fax: 303-237-8929PAID ., Inspection Line. 303-234-5933 � Building Permit Application PAID Mailing Address: (if different than property address) Address: , Are4741e,,,��, - -. Architect/Engineer „. ,�mmmw� Contractors Cita License #a" Phone: Contractor E-mail Address: Saab Contractors. mow' Electrical. ° ,-Plumbing: Mechanical: W.R. City License # W.R. City License ## W.R. City License ## Other City Licensed Sub: Other City Licensed Sub: City License ## City License ## Complete all information on BOTH sides of .this form 117 # 0 1 • A Y 2 e aw s 0 NEW COMMERCIAL wr s... ELECTRICAL A SERVICE UPGRADE s ,.:. NEW RESIDENTIAL '" ` COMMERCIAL COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc,) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE.. • o PLUMBINGr REPLACEMENT SYSTEM/APPLIANCE Pt w M pi or REPLACMENT MR auras rr� erl lr to De use a, etc.1 $ q $ LAq 0( q. FULF Stu's Gallons Amps Squares Other City of Wh6atR@ge CITY OF WHEAT RIDGE BUILDING AND NSPECTION SERVICES DIVISION 75001 29th Ave Wheat Ridge, CO 80033-8001 p. 301235.2855.f 301237M29 1111 11 1 1 P 1 111 Ili I I 1 111 Ell! 1111;qpIlligipill �i i 0 ' WINTUR 11 !1 i a mel i Vfli� 11 Aff�-ffg' flp)pftr�'� the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a co I mpleted Proof of Submission form from a required agency will not be accepted or processect A I A Date: 1Z, i IMEM33mm WY OL"—TAU19 )p -__Wheat Ridge Fire Protection • Arvada Fire Protection • Wheat Ridge Water District • Consolidated Mutual Water District • Valley Water District • Denver Water Agency Notes: am a duly authorized representative of the agency below, hereby acknowledge receipt of documents necessary ated above. • Wheat Ridge Sanitation District • Clear Creek Sanitation District • Fruitdale Sanitation District • Westridge Sanitation District • Other Signature: Date: (Agency Repreientative) FOR OFFICE USE ONLY Y City of`" C> - Building & Inspection Services Division z o G 7544 W. 24;x' Ave., Wheat Ridge, CO 54433 Pian Review Office: 343-235-2855 * Fax. 303-237-8929 Inspection Lime: 343-234-5433 Building er it Application Pleas* tomPlete all ;highlighted aro"'on moth sides of this fo * Incomplete sWications may not e processed. (57 Property Address: "rOr prnt): Property Cerner Eni l* pilin Address: if different than property address) Address; rchite E l r E-mail*. Phone.-_ 01, Contractor: Contractoras C4 License .- l�hcrne: � Contractor tt E-mail Address. kya,0 . trb Contractors - Electrical: Plumbing; Mechanical: W.R. City License # W,R. City License # W.M. City License Other City Licensed Sub: Other City Licensed Sub: City License # City License Complete all information on BOTH sides of this form .o• S fLA) t -t>42) -4- *- 6 " I 1�11 { Sq. FULF Stu's Gallons Amps Squares Other WHEAT RIDGE FI P DIST DOING THE RtCHT THINGS AT THE RIGHT TIMES FOR k REAS 3880 Upham Street Wheat Ridge, Colorado 80033 # ph.303.403.S900 # www.wrfire.org flIIM � M► :tlNlr !ur REV 1212012 Plan Review Report 1 of 2 WHEAT RIDGE FIRE PROTECTION DISTRICT P LANS S ARE APPROVED AS SUBMITTED PLANS A RE C ONDI TIONALLY APPR VED, See Flan R eview Co mments below. A respo is not required. M MU Tenant identification. Each occupied tenant space provided with a secondary exit to the exterior or exit corridor 40& 11,2 shall be provided with tenant idenfification by business name andlor address. Letters and numbers shall be posted on the corridor side of the door, be plainly legible and shall contrast with their background train electrical disconnects labeling. Electrical rooms containing the main electric disconnect she# be identified 6063-1.2" M with a permanently affixed sign with letters not less than one (1) inch (25mm) in height on a contrasting amended 4ackground to read "MAIN ELECTRICAL DISCONNECT co — nn - acis — shiff v b - a - - I d 't' M -- a - d - w number in accordance with the electrical code. amended ZMA M REV 12/2012 Plan Review Report 2 of '2 WHEAT MOE FIRE PROTECTION DISTRICT City of COMMUNITY DEVELOPMENT 7615 West 38th Ave. B#101 ypaden@aol.com Address: �� Brother plumbing, Heating, Electric L3 0 . ..... ..... ccarwin@brotherspiumbing.com Electrical: W,R, City License # Other City Licensed Sub: City License # Plumbing: W,R. City License # Complete all information on BOTH sides of this form I i N I ;I I i i I I i i I � 1 11 111 1 1 11 1 R I • Sq. FUL F — Btu's Gallons 20 Amps Squares Other F OR OFFICE Complete all information on BOTH sides of this for Sq. ROO Stu'a Gallons Amps Squares Other I V Ixf 108" C) z lz 108" a€ c uni mmaiertais to a usec, i .) Sq, FULF tutu's Gallons Amps ouare dtl eru m a 0 M w 0 I U U E 6 00 oz) I 0 N N a a i a� 0 2 DEMO PLAN 3/16" x P -e) Z AZ1� ► +' 1) DRAAING5 ARE REPRESENTATIVE DOCUMENTS TO FACILITATE CONSTRUCTION. CONTRACTOR SHOULD FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. THE HEIGHTS OF GRADE INDICATED ON DRAAIN(55 ARE APPROXIMATE AND ARE PROVIDED FOR INFORMATION ONLY. NOTIFY DE5167NER OF ANY ALTERATIONS OR DISCREPANCIES BEFORE PROCEEDING WITH AORK AND IMMEDIATELY UPON DISCOVERY. 2) THE CONTRACTOR SHALL BE RE5PON51BLE FOR DISTRIBUTION OF DRAAIN65 TO THE 5U5- CONTRACTOR5 UNDER HI5 JURISDICTION. 5) THE CONTRACTOR 15 TO PERFORM ALL DUE DILIGENCE NECESSARY TO DELIVER WORK IN ACCORDANCE WITH THE REGUIREMENT5 OF CITY OF WHEAT RIDGE BUILDING DEPARTMENT. 4) THE CONTRACTOR SHALL ACKNOWLEDGE THAT JOB 51TE ARE DIFFICULT AND DANGEROUS PLACES TO AORK BY NATURE. AS SUCH, ALL NECESSARY PRECAUTIONS RILL BE TAKEN TO ENSURE THE SAFETY AND GENERAL HELL BEIN6 OF HI5 EMPLOYEES. 5UB- CONTRACTOR SHALL PROVIDE GUARDS, RAIL5, BARRICADES, FENCES, CATCH PLATFORMS, 5RID(S1N6, DECKIN6, AND NIGHT LIGHTING, ETC., AS REQUIRED PER CONTRACT WITH GENERAL CONTRACTOR. 5) DURING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR BRACING AND PROTECTING ALL WORK FROM DAMAGE, BREAKAGE, COLLAPSE, DISTORTIONS AND MIS- ALIGNMENT ACCORDING TO APPLICABLE BUILDING CODES AND STANDARDS OF GOOD PRACTICE. 6) CONTRACTOR SHALL MAINTAIN AND PROTECT ALL EXISTING CONSTRUCTION, SYSTEMS AND EQUIPMENT TO REMAIN OR BE REUSED '1) CONTRACTOR SHALL MAINTAIN CLEAR AND UN055TR14TED ACCESS FROM ALL FLOORS TO STAIRWELLS AND EXTERIOR EXITS AT ALL TIMES. 8) CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR PROTECTING ALL DANGEROUS AREAS FROM ENTRY BY UNAUTHORIZED PARTIES. Q) THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE REQUIRED TO COORDINATE WITH OTHER SUBCONTRACTORS AS NECESSARY. EACH SUBCONTRACTOR SHOULD COMPLETE WORK ON AN EXPEDIENT AND REASONABLE SCHEDULE, IN A MANNER THAT DOES NOT DELAY OTHER TRADES AND SUBCONTRACTORS FROM COMPLETION OF WORK. 10) THE CONTRACTOR SHALL KEEP SUFFICIENT WORKMAN ON THE JOB 51TE AT ALL TIMES TO PERFORM AORK IN THE MOST EXPEDITIOUS MANNER ;CONSISTENT WITH (500D WORKMANSHIP, 5OUND BUSINESS PRACTICE AND IN THE BEST INTEREST OF THE OWNER. INCOMPETENT WORKERS RILL NOT BE RETAINED ON JOB SITE. II) ALL AORK SHALL BE DONE IN A NEAT AND WORKMA4 LIKE MANNER. THE CONTRACTORS SHALL KEEP THE PREMISES FREE OF ACCUMULATIONS OF AA5TE MATERIALS, OR RUBBISH BY HI5 OR SUB - CONTRACTORS OPERATIONS. THE PROJECT SHALL BE LEFT GLEAN, OLEAR AND SAFE TO THE SATISFACTION OF THE OWNER, AND SHALL BE BROOM GLEAN AT THE 50 OF EACH WORKING DAY. 12) CONTRACTOR SHALL MAINTAIN A DUMPSTER TO CONTAIN THE DEBRIS. SUCH DEBRIS SHALL BE REMOVED FROM THE 51TE AS REQUIRED BY THE CITY OF BOULDER 'GREEN POINTS' PR06RAM, AND SHALL BE DISP05M OF IN A LEGAL MANNER. mmm (E) GL6. HT.- VARIES BUT ABOUT 15'-0" AT CENTER 13) THE CONTRACTOR SHALL ARRANGE FOR THERE TO BE LEGAL SANITARY FACILITIES MADE AVAILABLE, ON OR OFF SITE FOR USE OF HI5 EMPLOYEES AND ANY TRADES. IF AN ON51TE FACILITY 15 TO BE USED, IT SHALL BE SELF CONTAINED AND REMOVED PRIOR TO COMPLETION OF THE WORK. 14) STRUCTURAL MEMBERS SHALL NOT BE IMPAIRED OR UNDERMINED 8Y IMPROPER GUTTING OR DRILLING. 15) CONSTRUCTION ACTIVITY SHALL BE RESTRICTED TO TIME AND DAYS AS AGREED BETWEEN THE CONTRACTOR AND OWNER AS PART OF THEIR GENERAL CONTRACT. 16) ADJACENT PROPERTY 15 TO BE PROTECTED FROM DAMAGE DURING THE 60145TRUCTION PROCESS AND THAT IF DAMAGE OCCURS; RESTORATION TO THE ORIGINAL CONDITIONS 15 TO BE COMPLETED WITHIN A REASONABLE TIME FRAME TO BE DETERMINED BY ARCHITECT. 17) CONSTRUCTION STA61N(s AND STORAGE OF MATERIALS SHALL BE LOCATED ONLY IN AREAS SPECIFIED BY THE OWNER OR ARCHITECT. MATERIALS TO BE PROTECTED FROM DAMAGE AND MOISTURE AT ALL TIMES, IS) ALL TRASH AND CONSTRUCTION DEBRIS SHALL BE KEPT COVERED IN APPROPRIATE REFUSE CONTAINERS AND EMPTIED ON A REGULAR BASIS. PAVING, LANDSCAPING AND OTHER CONTRACTORS SHALL NOT VISP05E OF LEFTOVER MATERIALS ON ADJACENT PRIVATE PROPERTIES OR ON PUBLIC ROADS. CWA ARCHITECTS 4400 OSAGE DRIVE BOULDER CO 80303 t.720.644.6699 f.303.835.4540 -K v � i c V CD 1:7) I O cn cn Q) 00 0 uj U W cn Q J " J� U� 2:11 1A c� C �, f Q- 0 2 W 0 Z F- _O cA H d d' W W U cr 11 I Q � 0 M UJ N U) cy; D1.1 (E) GL6. HT.- / i l J IF II r - --- --------------- C -- GLI1 r -- : ------- - 1 - - - - -- (PHONE ; i I L J ;- -j I - - r,l._, — I I II II II \ II II I I , II . \ .,,..,. IL----- - - - - --I J \\ SAVE AS MICH OF THE `CEILING .. — — — — r — — bRID AS 19 FEASIBLE I - - - - -- - - I r i �l (E) GL6. I� I ._ .... SAVE ALL OASEP OW I I I FOR POSSIBLE FaW� I I // II --- � L--- i II / --- - - -- L z � — — — — — — — —. ,1 INVESTIb�ATE IF ,> IN DEPTH / t II r � " � / (1=) GL6. HT- 1 J I // / / INVESTIGATE IF TNI4 / COL" AW CAN BE / RE=ED IN SIZE / � / PLAN KEY F L........ .._ .. .. ......... .............. _ .... .. .�... .. _._ .... ......... r ---- " EXISTING WALLS ----------- -.,. C _ WALLS AND DOORS TO BE REMOVED FIXTURES / APPLIANCES AND COUNTERS TO BE REMOVED CWA ARCHITECTS 4400 OSAGE DRIVE BOULDER CO 80303 t.720.644.6699 f.303.835.4540 -K v � i c V CD 1:7) I O cn cn Q) 00 0 uj U W cn Q J " J� U� 2:11 1A c� C �, f Q- 0 2 W 0 Z F- _O cA H d d' W W U cr 11 I Q � 0 M UJ N U) cy; D1.1 STOP WORK ORDE-?, You are hereby ordered to stop work located at: X t, Date: Building Inspector: �rt . r CITY OF WHEAT RIDGE Building Inspection Diuision (303) 234 -5933 Inspection line (303) 235 -2855 Office ' (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type X347 Job Address A/f Permit Number 10_,;?y7 1 ' ❑ No one available for inspection: Time AM45P Re- Inspection required: Yes rNo When corrections have been made, call for re- inspection at 303- 234 -5933 Date: Inspectors DO NOT REMOVE THIS NOTICE ❑ No one available for inspection: Time AM45P Re- Inspection required: Yes rNo When corrections have been made, call for re- inspection at 303- 234 -5933 Date: Inspectors DO NOT REMOVE THIS NOTICE lI CITY OF WHEAT RIDGE Building Inspection Division J (303) 234 -5933 Inspection line (303) 235 -2855 Office'* (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type ,( Job Address Permit Number _1,0,7 , Y ,� '��r%"/' A-B� .�i�tir �i ✓a'PZp / �l/!s'! "dc it'.C:aeyfi�i7 , cy t✓��"d;sL� ,fit- �irl,�X/�lf l�.L�'7iJlr� o? P� ,� ''�T. �` s.9�i_'n Af ra_!i _ . _ , �e n r,.rs „� ... - ,-. G^lsaci.� _. _ ._..__ ., .L: r ir•� 7-' Ine avai for inspection: Time %fir AM red: No Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. i b 1c) vo - 1;;')/). 4T fl-) PT 1 a- F- INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE. INSPECTOR INITIALS COMMENTS: - Footings /Caissons - Stemwall /(CEG) Concrete Encased Ground - Reinforcing or Monolithic .Weatherproof / French Drain - Sewer Service Lines' Water Service Lines INSPECTIONS FOR PLANNING R ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. YOUR NO CONCRETE UNTIL ABOVE NAS BEEN SIGNED CONCRETE SLAB FLOOR - Electrical (Underground) Plumbing (Underground) Heating (Underground) nn NAT POIIR FI (FOR IINTII ARnVF HAS RFFN SIGNFO 'ROUGHS Sheathing Lath / Wall tie Mid -.Roof Electrical Service' Rough Electric Rough Plumbing Gas Piping INSPECTIONS FOR PLANNING R ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Rough Mechanical - - ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING Framing Insulation - I FINALS 'Electrical 'Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage - INSPECTIONS FOR PLANNING R ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking &Landscaping - * *NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY ISISSUED. FINAL. INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER i lJ ♦ i i CITY OF WHEAT RIDGE r wr Building Inspection Division (303) 234 -5933 Inspection line � (303) 235 -2855 Office • (303) 237 -8929 Fax All INSPECTION NOTICE r Inspection Type: - r Job Address: y Permit Number: ❑ No one available for inspection: Re- Inspection required: Yes ( " * When corrections have been made, cs Date: _! / /[ /G' Inspector: ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: OV1 Job Address: Permit Number: ❑ No one available for inspection: Time t�•'S.f M Re- Inspection required: Yes No When corrections have been made, call for r e - inspection at 303234 -5933 -Date: ,2S /ca Inspector: DO NOT REMOVE THIS NOTICE F a, T; INSPECTION RECORD OCCUDancylTyDe INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. V if if w I II r,. 9. Iv a Wv�l f' �r s u INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS :COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic ROUGH Etie Sheathin Weatherproof/ French Drain Lath / W Mid Sewer Service Lines Roo Water Service Lines Electrica i 'POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED i' e .z CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating':( (Underground) `DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGH Etie Sheathin Lath / W Mid Roo Electrica e ., e i I Rough Electric Rough Plumbing Gas Piping Rough Mechanical 'ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING: Insulation Drywall Screw FINALS ' Electrical. Plumbingi e Mechanical Roof Building Final 6 /D �p J/, Fire Department R.O.W &'Drainage INSPECTIONS FOR PLANNING &i ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking &!Landscaping ** NOTE. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTEAUTHORIZATION OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CEF PROTECT THIS CARD FR TE OF VCCUPANCY IS ISSUED WEATHER ♦ e CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: 16z ❑ No one available for inspection: Time (: /S AjPM Re- Inspection required: ,Yes No 1 When corrections have been made, call for re Inspection at 303 -234 -5933 Date: 7r f /���d Inspector: 44 f DO NOT REMOVE THIS NOTICE City of heat edge Date: titUNiTy DEVELOPMENT t � Plan # Building & Inspection Services Division Permit# 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 -234 -5933 Building Permit Application PrDlJ Ad dress: a-/S n &V 3S l���tf j/ /3� Property Owner (please print): �!/lelwklP SByVjS plz�/ Phone: Mailing Address: (if different than property address) Address: City, State, Zip:' Contractors City License #: JG� G�f 1 / 1 9 1 Phone: C3 / y �S Sub;Contractors: �p� Electrical: Plumbing: Mechanical: City License # City License # City License # Des�npfiioti ��fi work; > f Contract a ue• / Review Fee (due at time of submittal): Squares BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants; easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full - responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRA yC�JTOR). or / (AUTHORIZED REPRESENTATIVE) , of ((OWNER) (CONTRACTOR) ti PRINT NAME: / el JL /(�//) SIGNATURE: �""7 � '� DATE: Bldg Valuation: $ ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: 46 -Z Job Address: 7G 16' uJ 3 1& Permit Number: ❑ No one available for inspection: Time P M Re- inspection required: Yes d Vd— * When corrections have been made, call for re- Inspection at 303 -234 -5933 Date: Inspector: �� DO NOT REMOVE THIS NOTICE CERTIFICATE OF COMPLETION City of Wheat Ridge 7500 W 29th Ave Wheat Ridge CO 80033 Permit# 100927 Issued: 06110110 Stipulations: Tenant Finish for Office /Warehouse This certificate verifies that the building constructed and/ or the use proposed of the building and /or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. Site Address: 7615 W. 38th Ave. #B 109 -123 Parcel Number: 39- 233 -21 -030 Owner: Peter Freeman 3020 Zenobia St Wheat Ridge CO 80033 Contractor: Christopher Sands Horizon Builders LLC PO Box 826 Lyons, CO 80540 For the Following Purpose: Comm. Tenant Finish Cole Editions NO change shall be made in the USE of '2003 ICC /2005 NEC this building without prior notice 2003 ICC /2002 NEC and a new Certificate of Completion 1997 UBC /2002 NEC from the City of Wheat Ridge. S pr i nkler System S � ( /i ng Inspector Zoning Administrator CERTIFICATE MUST BE POSTED BY FRONT DOOR OF COMMERCIAL OCCUPANCIES � fL4 L71:�, AZC�41 EGTS 8600 W, -38� &ve cl FMI maw 1%41 V 77 N 4 — ks,4 N 1 �� �j 1-2 -1 z�z 30110N SIMI 3AOW3d ION 00 a :joloadsul 'l7 7777 -- 7:a1ea C669-We-E0E IV ugiJoadSw -ei joj peo `epaw ueeq eney SUgJPa»00 uegM M ON so), :paambaa uoiloadsul - aa Wc�lNUV y, i ow!j :uoiloadsw jo} opupene auo ON ❑ 77 7-71 G -s,' :aagwnN I!wJsd :ssajppv qor :adA l uoljoadsul 33110N N01103dSNI k xe.4 6e68-L£Z (£0£) • eq'40 958e - 9£Z (£0£) eury uoljoadsul EE69 -tCX (COG) uoisinla uol}oodsul 6ulplin8 3001H IV3HM -40 A110 I i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: y > Job Address: f l_5 60 36 ? r_ Permit Number: zo / _ 2 0 S — ❑ No one available for inspection: Time ,1 2 AM /PM Re- Inspection required: Yes No When corrections have been made, call for re-inspection at 303 -234 -5933 Date:, 2 /O Inspector: OT REMOVE THIS NOTICE OTICE `s CITY OF WHEAT RIDGE / ~ Building Inspection Division 1 (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: L. K_ Job Address: N f5 -f�S Permit Number: ❑ No one available for inspection: Time /i) ; / %)_M_� M Re- Inspection required: Yes No When corrections have been made, call for re- inspection at 303-234-5933 Date: 5 - Inspector: DO NOT REMOVE THIS NOTICE � e CITY OF WHEAT RIDGE r Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: f k r Job Address: l ' U Permit Number: v � � ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes No *When corrections have been made, call for re inspection at 303 - 234 - 5933 Date. -.� -! /i inspector;. DO NOT REMOVE THIS NOTICE e ` , e CITY OF WHEAT RIDGE ' Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 7 /� 9 - - ' 3 Permit Number: I&c)cl -? 7 Il f I L O H c R rr t ❑ No one available for inspection: Time !!' r AMl M Re- Inspection required: Yes No ' When corrections have been made, call for re-inspection at 303 -234 -5933 -_ Date: � / � 7l� Inspector: DO NOT REMOVE THIS NOTICE ri t; L PERMIT NO: 101205 JOB ADDRESS: 7615 W'.38TH AVE DESCRIPTION: Install 800 sqs of soffits in 05/12/2010 11/08/2010 Mountain Springs Plaza 149 Free Lance Carpentry b City Of °(` Wheatj�idge Date: COMMUNITY. DEVELOPMENT Plan # Building &Inspection Services Division Permit# 7500 W. 29 [ Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application Oro s 115 W. 3$ +k kae Property Owner (please print): m,,,tnkouh Cl n6--, P 62ct L U Phone:303' 3 06 - 1 00 0 Mailing Address: (if different than property address) Address: Wesfern Cen +er.5 1 r � ftirUr- R OoAI) # 15 City, State, Zip: t t _ ra?cfo J-M 1J Contractors Citv License City License # Plumbing: City License # 1 8CTIDt O Of tk -L.5+109 (1 0fAPU Oh ex�et•ior 5oi:-Fi� -s th front of On;f5 1(9 tol�rl c�J 7'u aW) -P h15L S t Squares BTU's Gallons Sq Ft. Mechanical: City License # Co ract Value: $ - Do.AD Review Fee (due at time of submittal): $ OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, Hiles or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: SIGNATURE: DATE: Bldg Valuation: "4' City of Wheat Ridge Comm.' Tenant Finish PERMIT -100927 PERMIT NO: 100927 ISSUED: 04/12/2010 JOB ADDRESS: 7615 W. 38th Ave. #B 109-123 . EXPIRES: 10/09/20.10 DESCRIPTION: Office/Warehouse tenant finish CONTACTS owner 303/859-1724 Peter Freeman sub 303/245-8600 Christopher. Sands ' 10-0112 Horizon Builders LLC :PARCEL INFO ZONE CODE: UA FUSE: UA SUBDIVISION:' 0343 '.BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED.- PROJECT :VALUATION: 8,000.00 FEES Permit Fee 199.30 am Plan ReviewFee 129.55 Total Valuation .00 Use Tax 144.00 AA PP'' ''JJ TOTAL 472.85 b'-L~tLOS4 Conditions: Subject to field inspections. Must :comply w/ 2003 :IBC, IMC & IPC & 2005 NEC. I hereby certify. that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions4 of record; that all measurements shown, and allegations made are accurate, that I have read and agree to abide. by all conditions printed on this application th a e full responsibility for compliance with the Wheat Ridge Building Code.'(I.B.C) and all other.. applic as d dinances, for work under this permit. Plans subject to. field inspection. Z2l 0 Signa ure o ,contractor/owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of. the City.,. 2. This permit shall expire 180 days from the issue date. 'Requests for an extension must be received !prior to 'expiration date. An extension maybe granted: at the discretion of the Building Official 3. If this permit expires, a new permit may be. acquired for a fee of one-half the amount normally required, provided no changes have been or will be made. in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have beenor if suspension or abandonment'. exceeds one (1) year., full fees shall be paid for anew permit 4. No `work of any manner shall be done that will change the natural flow of water causing a drainage: problem. 5. Contractor shall notify: the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases:'.. of the job 6 The. i ssuanee: of a permit. or tha 'a nnrnval of . tlrawinaa nno anPrifirat,ona aha11 not ha rnnatn,ad to he a permit for, nor. nc 03)235-2855 HE :FOLLOWING BUSINESS DAY.' i a a City of Wheat midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application Property Address:: %4!~ 15 VAeg- ' 38~, C9v iA 6 1C /~~ic Property Owner (please print): (P2AiE!~f C"~ Mailing Address: (if different than property address) Address: 3 Cj2(73 e,wltJi c City State Zip- Date: J)yl LN(l'~1016~ Plan # l r . Permit # 6.-123 .'3d7 - 8' ~Qy~irc~~, 6'b2 ~2 ' ~e U G~,'~ I CJ ?b21 Z Contractor: ~~~r5 'L4 e--- Contractors City License M Phone: SubwGontra~tors Electrical: Plumbing: Mechanical: City License # City License # City License # D'es'rriv\atlonb_fj_w~_orla~ - ~`OCah~11~ t` ~~~s Contract Value: J~h tc~t 1r V~~ ~P~ lit $ Sf,eqcn::~ e~ q,v.`~) Qr 2 Review Pee (due at time of submittal): Squares BTU's Gallons Amps Sq Ft. C OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal. owner of the property to perform the described work and am. also authorized by the legal. owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) 1 CONTRACTOR or ((~AlUTHORIZED REPRESENTATIVE) - (OWNER) (CONTRACTOR) f PRINT NAME: U' 1,A t S ~-a ' SIGNATURE: DATE: Dot 7 ~ 1 4 ZONIh,G COMM~NT$ 5 sszi'`a ~ ✓ 1, ~ r ~ ~ a r ~ p ~~">i ~ ~ ' ~ v r' ~ RBV1eWC ii' r~ 1 /s S ~ ~ -r r e ✓ av 7 l .y r t a/, r , srt t. z. ~ ~ r ~ i y = . d FIRE bEPAk7MENT ~ approve5l gv/ comments ❑ disapproped t7~no reytew requl~ed Bldg Valuation Q/3`J, 60 r; c DESIM9lBY-Pogf ro9iS1ER 1343)BFYTIIFPHONENiDFPI(' e~?%~~ j v °P°6 - r w m svu MEM u s ~ ~ i wu~~s~m wmnx ~r a *740 a d ~ a Y t0 p w 00 a m O W o W > Z ny Z ~ O m G N C U L Yf3WZw3 `o crno~t5 U corn ~ ~ 8 ci c L B (O t O CO O O v a U O N m co N C ~2 E2 w :S -9 8 r 2'; ~o a ~Vr EQ.c d N O O c ~QaU-w O c C E 10) W ~ 0(O aY N T - O O 00 O tgQo.m~E • . . V O co co Q L N Q N v~ v n fl y L 01 .J.. O co N N O r2 .o L N d J N 7 LL p p F-~22o Q C Nd O W> O N m O mN N M-' N N It N O N N C J op (03) dUrn 0 C- p ; O- U {`p ~ U n, ~ as E'90 a 22 > U Q m aatA .CV c ~w2unwz ;,mss o~ a~ m -----------i C c n~ W l6 o t N '9 o a N Z W C 0 N c c v J ~ a £ (U Q Q J_: w I i I 1 I I I I I 1 i 1 1 1 1 1 a ~ O N I 'y N Q J ~ ~ ~N I N W'~ O LL C N aE < O E a o Z C I IL O M V N 1 1 1 I F ~ I I N W - ► I 6 M m N C II N r 2 n ` O(p~ 7 c°~IUOU LO < m (p)(.) O d > a c o a N N O (1) U c 3 ~ J N W O E m O ` o V/ L L O ' City of Wheat Ridge _r- Commercial Demolitio PERMIT 100910 PERMIT NO: 100910 "ISSUED 04/09/2010 JOB ADDRESS: 7615 W 38th Ave. #B 109-123 EXPIRES: 10/06/2010 DESCRIPTION: Interior Demo: -removalof =non-bearing walls CONTACTS owner 303/859-1724 Peter Freeman sub 303/245-8600 Christopher Sands 10-0112 Horizon Builders LLC **'PARCEL _INFO ZONE CODE: UA USE: UA SUBDIVISION:.: 0343 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED : PROJECTVALUATION: 6,000.00 FEES Demolition Fee 50.00 v 71 Total Valuation .00 TOTAL 50.00 Conditions:' Subject to :field inspection. No additional work to. be started without building permit for remodel. I hereby certify. that the setback distances proposed by this permit' application are accurate, and dof not violate applicable ordinances, rules or regulations of the City of Wheat 'Ridge or covenants, easements or restrictions of record, that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions:. printed on this application dth me full responsibility for compliance with the Wheat Ridge Building Code '.(I.B.C) and all other ssu apple b e RA dinances, for work under this permit. Plans subject to field inspection. Si .cure o contractor/owner date 1. This permit. was issued in accordance with the provisions set forth in your application and is subject to the laws of the :State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or. any other applicable ordinances of the City..: 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of'. the Building Official 3. If this permit expires, !a new permit may be :acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or'. abandonment. exceeds one (1) year, full fees. shall be paid fora new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5 Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive.' written approval on inspection card before proceeding with successive phasesof the. job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor. an japprova o ny violation of the provisions of the building codes or any.; other ordinance, law;. rule or regulation. an p w is subject to field inspections. t Signatur of ief Building Official date ! INSPE TION REQUEST LINE: (303)234-5933 'BUILDING OFFICE: (303)235-2855 . REQUESTS MUST BE MADE BY.'3PM ANY BUSINESS DAY FOR INSPECTION THE :FOLLOWING BUSINESS DAY. City of Wheatljdge COMMUNITYDEVELOPMENT Building & Inspection Services Division 7500 W. 29t" Ave., Wheat Ridge, CO 80033 Date: Plan # Permit # GU61ffi Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building, Permit Application Prdpgrty Address; S ~>h 384` -54< Property Owner (please print): Phone: ' X59- i7Z ~f Mailing Address: (if different than property address) Address: 3i:5>2-C) 2 e vLC~ 1~ i City, State, Zip: Con>lractor: _ l~ f- i 2 c> v., 41.E t~`t r/'~ ~ t... Contractors City License Phone: '720 3 o - ~1 70 Electrical: Plumbing: Mechanical: City License # City License # City License # bescrtpt►on~"o#.worksi t~~Vv`..CD ` `G tti - 1Y~2+.ti6 Vim.` nV Contract Value: $ Review Fee (due at time of submittal): Squares BTU's Gallons _ Amps Sq Ft. S > $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I.have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for. work under any permifissued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRALTO or (AUTHORIZED REPRESENTATI ) a OWNER) (CONTRACTOR) PRINT NAME: SIGNATURE: DATE: O approveil~w/eomrtepts ❑ disapprouedF p noreview-requared~~. Bidg Valuation: $ _ ~ _ n~ City of Wheat Ridge Commercial Plumbing PERMIT - 092502 PERMIT NO: 092502 ISSUED: .09/17/2009 JOB ADDRESS: 7615 W 38TH AVE EXPIRES: 03/16/2010 DESCRIPTION: Install 80 gallon electric hotwater heater CONTACTS owner 586/260-7812 Great Clips Training Center sub 303/340-3400 Stephen Jusseaume 01-9312 BFP Plumbing Serv. dba Benjami PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0343 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 1,000.00 ..FEES. Permit Fee 50.40 Total Valuation 00 Use Tax 18.00 TOTAL 68.401 X5'""^°.3°.•?j K, ,.Conditions For Great Clips Training Center. h,.Subject to field inspections. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work :under this permit. Plans. subject to field inspection. Signature of contractor/owner date y 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3.. If this permit expires, a new. permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not F^= exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. `-4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5.. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. G. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for,. nor e an a an violation of they provisions of the bmlding codes or any other ordinance, law,sule or regulation. Al is aubj ect to field inspections. Signatuilding Official date iSPSttTION REQUEST LINE: .(303)234-593.3 BUILDING OFFICE: (303)235-2855 CQUESTS MUST. BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.. ~~oF wtrear~a City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 oocoRaoo Inspection Line: 303-234-5933 Building Permit Application Property Address: H I. 7A-) h Ale. Property Owner (please print): (7 rest-t (pf f j Un I V) Mailing Address: (If different than property address) Date: Plan A Permit* GO q~t~OA, 2m0- 7812, Contractor: Contractor License Phone: / ZQ - 6-33P 0(oo 1 Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ 000 Des`cr_ip/tiion. of work: t (as calculated per the Building Valuation Data sheet) i1/1 +O II (5 Plan Review (due at time ofsubmdtaq:$ l VS~g. )/q.Ft../"L...F It add d Squarees.. BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE Of UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. 0 ~1 - CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REI PRINTNAME: 5r',C5NJE'Al R Jtrse+rlutnf- SIGNATURE: (CONTRATOR) ZONING COMMENTS: Zoning: Reviewer: I PUBLIC WORKS COMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer DEPARTMENT USE ONLY FIRE DEPARTMENT:: O approved w/ comments ❑ disapproved ❑ no review required OCCUPANCY: Bldg Valuation: 5)!fl F "RE^T City th of Wheat Ridge Building Division Date: doe CC ~I G =y m 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Plan M ooo Inspection Line: 303-234-5933 Permtt#-{ Building Permit Application P;ppertyAdres'`t('0 j w 3g lob C c~ 8603; Property Owner (please print): Wp e((h Cevi g(s tL Phone: 303, S&,-1CCO X123 Mailing Address: (if different than property address) ~0.YCt I ~e✓ c~ o~ct Address: State, u"ontracto : to Contractor License r) ` f SSb Contractors Electrical City License Company: Exp. Date: Use of space (descrrr tion): u Phone: LNG-017~ Plumbing City License Company Exp. Date: Rescnpt~ ~of«woFk Sq. Ft./L.Ft added: Squares BTU's x Mechanical City License Company: Exp. Date: c~ Approval: construction value: $ (as calculated per the Bu)ding Valuation Data sheet) Plan Review (tlue at time of submittal): $ L ~ ~ 7z/L,C 4 8" loq Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. / C/RLCE ONE(Q~l RACTOIR) or PERSONAL REPRE D ATIVE o (O R) (CONTRATOR) PRINT NAME '~+J .XSIGNATURE: Dale: Z" 7 Ln N dk~ Norma c E c E a s c m d N L F O 3 ~ Z H m a ~ 3 Z c a N ~ N 0 c U O ~ w U a E ~ ~ , LL E H im O I . E m I ( 1 uJ U J OG Z U U ^CCL ' U Q Z l - U Z- v F- - Z, C.: x z ii O - T N N O .S 3 M M Z ~ E Z D ~ Z - F = G w ' U ~ O y. z Q 2 \s Z rv 'l. z I Z FF N - 3 ifs n0 N - N ~c I 9 PM Ij qmmlmffib~ I c7 z V ~J O J \ N ~ \n 7 l E y~ V Q \ iLi E t l Z sy ~ ~ N _ 3 ~fp` N fju 7615 W 38th Ave, Wheat Ridge, CO 80033 - Google Maps Address Page 1 of 1 http://maps.google.com/maps?hl=en&q=7615+W+38th+Ave,+Wheat+Ridge,+CO+80033... 5/28/2009 ~►~i . r, CITY OE:WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: bdl • W-M `,09W r a F S Job Address/Permit Number: 98'71t A 5, 9167 11199 S c p..No one available for inspection: Time AM/PM Re Inspection required: Yes . Y When corrections have been made, call for re-Inspection at 303-234-5933 Date: 6? B7 a Inspector: DO NOT REMOVE THIS NOTICE OWheat Ridge *ircial Demolitio PERMIT - 080298 . ISSUED: 04/03/2008 py'Ave~. 8-119 EXPIRES: 09/30/2008 e+o1z, non-etruct walls, carpet, etc... Western Centers otG Burcham 07-0084 Colorado Interior Finiehea USE: UA . gLOCK/LOT#: 0/ > 4~k3- ~ "A ESTIMATED PROJECT VALUATION: 3,500.00 Ij'~ FEES 50.00 . . . . . . .00 50.00 y t~ , a.nterior walls. d'zekancee propoeed by thie permit application are accurate, and do not violate applicable ot the City of Wheat Ridge or covenante, eaeemente or reetrictione of record; that all titpxM inade are accurate; [hat I have read and a9ree to abide by all conditione printed on this ~A~ gyx ~ -tp12 BGeponeibility for compliance with the wheat R3dge Huilding Code (I.H.C) and all other for vork under thle permit. Plane aubject to field inspection. 9 4~ aate ~0~ a~pa~ ~py~pC} yy aC4or89ace with the provieione eet forth 1n your application and ie eubject to the lawe of the ypptng Regulatione and Building Codee of Wheat Rid9e, Colozado or any other applicable C11Y* , . ~iyys.y$p,$8ys.from the iseue date. xequeete for an exteneion muet Ce received prior to expiration f I 'payr,jjp~gsasltedat the diecretion of the Building Official. t -,{ijyt" y~pgw'petimit may be acquired for a fee of one-half the amount normally required, providetl rto p yy. yk11 §o.mdda1n the original plane and speciEicatione and any euepeneion or abandonment hae not Yaps Yr ¢6have been or if euepeneion or abandonment exceede one (1) year, full fees ehall 3~ .y ~ t~ ~,y7y{,yS rys doiie that will chan9e the natural Tlow of water caueing a drainage problem. Iu}ti~'tN~ IbAxding I°apector twenty-four (74) house in advance fox all inspec[ione and ehall receive yq~pij Cyzd beEore proceedang with eucceseive p~aee of the job. 4,f t pY EkYe Appzoval of drawinge and epe<ificatione ehall not be cone[rued [o be a pecmit for, nor i yisti,qp p[.:the pzoviaione of the Luilding codee or any other ordinance, law, rule or regulation. }r ;~r 4' to fieldinepections. ~ I date ,.:C~ul~ll ~iY t'!~'Q£61a1.. r~~'~{~gy_.~pp13) ANY 48US2NESS DAY FORNINSPECTION(THE,FOLlAWING BUSINESS DAY. , ~~~~W HEArqO o t~ m C~LORPp~ City of Wheat Ridge Building Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855' Fax: 303-235-2857 Inspection Line: 303-234-5933 Property Address: Property Owner (plee Mailing Address: (if different than property address) Address. City, State, Contractor: r.,.,r.a,tnr I.ir.ense Phone: , Sub Contractors: Electrical City License Plumbing City License Company. Company Mechanical City License Company'. Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: ma ~/r~ : D1•S e Coostruction Value: $ Use of space (desCription) (as calculatedper fhe Building Valuation Data sheet) Description of work: Plan Review (due at fime of submittap: S e . Sq. Ft./LFt added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify Ihat the setback distances proposed by this permit applicalion are accurate, and do not violate applicable ordinances, allegations9made ere aocu ale{ tha\t Inhave i ead and ag ee to abide 6y all condi4rons pnnted onr his h application sandmhalsl assumeafu~ll responsibiliry for compliance with the Wheat Ridge 8uilding Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under lhis permit. Plans subject to 8eld insnection. CIRLCEONE:: (OWNER) (CONTRACTOR PERSONALREPRESE4NTATIVE~o(Y` WNER) (CONTRATOR) ~ ~ SIGNATURE: Date: PRINT NAME: JGf DEPARTMENT USE ONLY ZONING COMMENTS: Zoning: Reviewen PUBLIC WORKS COMMENTS: Reviewec OCCUPANCY: _ BUILDING DEPARTMENT COMMENTS: Reviewer. FIRE oEPARTMENT:: 0 approved wl comments ❑ disapproved ❑ no review required Bldg Valuation: $ Date: Plan Permit -(/~S -C)- DP/"O Building Permit Application 19(1 in A 6-irk 78.07 28 in ~ Specifications: Custom Manufacture: Channei Letters pan Channel Logo Box Faces: 3/16" green 2108 Face: 3/16"white plex Trimcap: Gold Lettering: Vinyl Lighting: 15mm White Neon Neon: White 15mm Sidewails: bronze Square Footage: 8 sqft Square Footage: 16.5 sqft Raceway: painted to match fascia Both logo box and pan channel letters will be mounted to one raceway. ~ ~ L07 s, I12 in 112 in 51NCH RETIIRNS 1/8 inch muted & painted 7 INCH TRIMCAP aluminum back ~ ~ q35,•3rl in 2• 1/41NCH WEEP HOLES (AT EVERY LOW POINT OF THE IETTER) City of Wheat Ridge ~prmmercial Sign PERMIT - 071238 ISSUED: 11/14/2007 a~~`'~~~ EXPIRES: 05/12/2008 38TI'I AVE ~~IP~'~~s ,1!fiwE "11 sign facing south. Rocky Mountain Fott & Ankle ~y~ 3fy~f423~-~5~0 61-9332 AMERICAN SFGNS & GRAPHICS, INC ,343}932-8477 E ~s`;~P~1E~+ INP!f~ USE: C-1 'PM` BLOCKILOT#: OI o-3a~ ~ESTIMATED PROJECT VALUATION: 3,000.00 #'►o F~'3~;, ~ t~ FEES . 108.30 ~~ft I~ae l~tax vaiu~rsoa . oo ga i tJ*e Tax 54.00 'i~~' .,T4',AL r•'~` • 162.30 . ~t approve'd, f; i~ t` 2.005.NEC & 2003 IBC. eaktlfy C~~setback dietancea propoeed by thie perm it application are accurate, and do not violate applicable ~ thiE IlaYtCpe. N},06 bt ~511atione of the City of Wheat ASdge or covenante, eaeementa oc reetrlctlona of record; Chat all I ~ 'Ey~ppp, yLNi,~lcllega accurate; that I have read and agree to abide by all conditione printed on thie y 1CkCitln ayti~ R1dge euildi~ Code Q.e.C) and all other ` e fulY reapone;bi 'ty for compliance with the Wheat Vl~piiqable RYr3lnancea,Por woiric und r thie pezmit. Plana eub7ect to field inepection. bg date ~j~i p~;X'yy~{ ~¢mQa accosdance with the provieione eet forth in your application and ie eubject to the laws of the Y,~~~e q],* co1plfddp oK{;to the Zoning Re9ulatione and Huilding Codee of Wheat Ridge, Colorado or any other applicab e R~ '.qrdii~n~la.pL 'CD{¢'C3tY.. ~fE ~}yS,g ~ieKpd,t~yjAyl exjtre 180 daye from the ieeue date. Requeate fos an exteneion muaG be received prlor to expiration An p,X~gy,q~ ~yy be gzanted at the discretion of the Huilding Official. rovided no ~`f th1g,i~~ti 4xp~?~,..a new permit may be acquired Eor a fee of one-half the amount nornwlly nequired, p pp, ,9x will be made in the original plane and specificatione and any euapeneion or abandonment hae not ~~~~y¢'kqeg (y) y~If changee have been or if euapenaion or abandonment exceede one (1) year, full feee ehall : Dc patfd faz d Mx?Ddsth~t. .~~tO ~roY# at .;~p Npnjkpt~all be done that will change the natural Elow of water caueing a drainage problem. CoAtx(lCt'oi.;d1M11 iwE3CY the Building Inspector twenty-Eour (24) houre in advance for all inepectiona and ahall zeceive wY1ttla appYOVat bn Snepection card before proceedin9 with eucceeeive phasee oE the job. nor W~y.,~p ;~~do pL #~pl2init or the approval of drawinge and epecificationa ahall not be conetrued to be a permit for, ~S~my~i~p~~~,µy).; Slation oE the provieiona of the building codee or any other ordinance, law, rule or regulation. ,~A31 g1aA rqy p ..ject to field inapectione. ~yp~.mg official date Kbpoturtl ~ . -285 +`~8!'. LINSs (303)134-5933 BUILDING OFFICE: (303)235 NESS }~J$~,"'$$ yADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSI DAY. . . i'.. . . YI-T' Fw"Eqr City of Wheat Ridge Building Division 7500 W. 29`h Ave., Wheat Ridge, CO 80033 " m Offce: 303-235-2855 * Fax: 303-235-2857 Inspection Line: 303-234-5933 C~~ORP~O Building Permit Application Property Address: Property Owner (please print):~ ~.dMailing Address: (if differenf than property address) Address: City, State, Zip i Contrector Contractor License Sub Contractors: Electrical City License Company: a! P 0 'C ,V77 Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: c4~ Construction Value: $ 06 Use Of SpaCe (deSCriptlon): (as calcWated per the Buildin Valuation Data sheet) ~ J [ Description of work: ~ ~ ~ ~i Plan Review (due at fime of su6miffaQ: $ .Ci~-~'~y Sq. Ft.ILFt addedi e-j ~ Squares BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT MeseoYreguifatloos ofthe ~Ciy odiseat RPdge~orcovena~ agree nt to s abeaseide meotsaol~ resvicNonsaof r cord; th t~all measu Pre~ments sho~wn~ and allegations made are accurate; that I have read and by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code Q.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permiL Plans subject to fleld inspection. IR E ONE: N RA R) or PERSONALREPRESENTA WIIERlj~~ORT ~ CLC: (OW )(COTCTO , ~~Jp.ly~ SiGNATUR Phone: Plumbing City License Company PRINT NAME. DEPARTMENT USE ONLY ZONINGCOMMENTS Zon ng: 1 GD / ~ \ Reviewec4~?y ~ PUBLIC WORKS COMMENTS'. Reviewer. OCCUPANCY._ Date: Plan#: Permit BUILDING DEPARTMENT COMMENTS: Reviewer. FIRE DePARTMEN7:: D approved w/ comments ❑ disapproved 0 no review required Bldg ValUation: c City of Wheat Ridge Comm. Tenant Finish PERMIT - 070519 PERMIT NO: 070519 ISSUED: 06/01/2007 JOB ADDRESS: 7615 W 38TH AVE EXPIRES: 11/28/2007 DESCRIPTION: Unit 5-101. Tenant Finish fora doctora office. CONTACTS owner 303/423-2520 Rocky Mnt. Fot & Ankle Center gc 303/284-2521 Scott Burcham 07-0084 Colorado Interior Finishes SUB 303/781-7984 Michael Nierling 07-0109 Endeavor Electric, Inc. PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION: 0343 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 17,000.00 FEES Permit Fee 363.10 Plan Review Fee 236.02 Total Valuation .00 t Use Tax 306.00 ~ TOTAL 905.12 Comments: Plumbing contractor must obtain license before calling for any inspections BM: Plans approved. Pending field inspection. Must comply w/ comments from Wheat Ridge Fire Diatrict. I hereby certiEy that the aetback diatancee propoeed by thie pemit application are accurate, and do not violate applicable ordinancee, rules or regulatione of the City of Whea[ Ridge oz covenante, eaeemente or reetrictlons of record; that all meaeuremente ehown, and allegationa made are accurate; that I have read and agree to abide by all conditione printed on thie application and that I aseume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other appl cable Wheat e Ordinancee, for work under this permit. Plane eubject to field inepection. ~-y- 7 gignature of contractor/owner date 1. This permit wae ieeued in accordance with the provieiona eet Eorth in your application and ie aubject to the lawa of the State ofColozado and to the 2oning Regulations and Building Codea of wheat Ridge, Colorado or any other applicable ordinancee oE the City. 2. Thie pemit ahall expire 180 daya from the ieeue date. Requeeta for an exteneion muat be received prior to expiration date. An extenelon may be granted at the diecretion of the euilding Official. 3. if thie permit expiree, a new pemit may be acquired for a fee of one-half the amount normally required, provided no changee tiave been or will be made in the original plane and epecificationa and any euepenaion or abandonment hae not exceeded one (1) year. If changes have been or if euepeneion or abandonment exceede one (1) year, full Eees ehall be paid for a new permit. 4. No vrork of any manner ehall be done thatwill change the natural flow of water caueing a drainage problem. 5. Contractor ehall notify the Building Inepector twenty-fouz (24) houra in advance for all inapectiona and.shall receive written approval on inspection card beEOre proceeding with succeesive phaees of the job. 6. The iesuance of a pemit or the approval of drawinge and specificatione ehall not be conetrued to be a pemit for, nor an appio 1 f, any violatlon of the provieione of the bullding codee oi any other ordinance, law, rule or regulation. All pl view ie eybjgtt to field inapectiona. INSPBCTION RBQIIBST LINB: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE EOLLOWING BUSINESS DAY. _ ~ d~ 33 ~ ~f WHEqT o ~ 'Pa Clty Of WhB1t Rldge Building Permit Number: Community DevelopmentDepartment Date: CQ~.~.~`;~CM & M U TI-.~",~~IL F BUILDV~G- PURWT A~'°.~ON Properry Owner: kC M+A/7" ~p~p7~ f/tp~Q7{~ Le ) Pxoperry Address: (~,9eS~" `V-~, ~ d6! Phone:~ Contractor License No.: 070 p ComPanY: C'.4MA Phone: OWNEWCONTRACTOR SIGNATURE OF l1NDERSTANDINGAND AGREEMENT I Buildlna Deot Valuafion Figure: $ Ihereby certirydhat the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations ofthe City of V&IUe:$. 17 ~GY Whea4 Ridge or covenants; easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by aIF P0Y1T11C-F08:$ conditions printed on this application and that I assume full responsibility for compliancewith theWheat Ridge Building Code (I.B.C) and all other applicable Wheat P1an ReviewPee:$ Ridge Ordinances, for work under this per/m/it. 13/I5ns subject to field inspection. jJSe TaX[$ (OWNER)(CONTRACTOR):SIGNED DATE7 TOtal:$ , (OWNER)(CONTRACTOR);PRINTED ~/Y`J~/l/fl~~/7fiy/✓1, DATE7 I//~ / Use ofSpace (description)• A7G6!'.I Description ofwork: Sq.Ft.added .A// BUII.DINGDEYARTMENTUSEANLY SIC: Sq.Ft.: ZONING.COMMENTS ~ . P,pproval: ' Zoning: ' . BUILDINGCOMMENTS: ~G"~ /~✓S~~ma-- , ~ .ii~ Approval: 10 u"'d~' ~~d~9 PUBLICWORKSCOMME 5: , APProvaL• . =1RE DEPARTMENT COMMENTS: Approvai: Occupancy: Walls: Roof: Stories: Residential Units: Electricai License No; Plumbing License No: Mechanical License No: Company: Company: t Company: Ex iration Da~t /Ex iration Dat • Expiration Date: Approval: / /y '41,1- Approval: Approval: / (1) This permitwas issued in accordance with the provis orh i n'if ~yourappiication and is.subject to the laws of the Stateof Colorado and to the ZoningRegulationsand Building Codes of W heat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue dale or (8) thebuilding authorized is suspended oca6andoned for a periqd of 180 days. (3) If thispermit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no.changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or ifsuspension or abandonmenE exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shali be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance foc all inspections andshall receive wrilten approval on inspection.card before proceeding with successive phases of the job. (6) The issuance of a permit or the approvaL of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the pmvisions of the building codes or any other ordinance, law, rule or regulation: All plan reviewis subjecf Eo field inspections.. Chief Building Official ~Oj ( I D cpty„ ~ S~~~I~~• ~D ~55U4 LP NEED: ~s -.Job valuation e GC S~ ontractor Nam ontractor License GC_ _ S~ SUB_ Contractor License renewal GC_ for Contractor License GC- Si _ Conttactor Insurance Cert. GC ~ Site P1an Fire Dept. Sign off Engineering details ~ TI o ti fication date: ' v May.31. 2001 3:18PM WHEFT RIDGE FIRE DISTRICT No.0589 P. 2 WHEAT R1DGE FIRE PROTECTION DISTRICT PO BOX 507 • 3880 UPHAM STREE'f • WHEAT RID6E, COIARADO 800840507 3034035900 • FAX303-940-0350 • YVWW.WRFIRE.ORG Colorado Tnterior Finishes May 31, 2007 Scoit Surcham 6127 Union Street Arvada, Colozada 80004 Re: 7615 West 38'" Ave., B 201 tenant finish. The following requirements are maae under the 2003 Intemational Fire Cade and N.F.P.A. 10 Mopted by the Fice 8aard of the Whesc RWW Fire protection District and fhe County Commissioners of Jefferson Couuty, Colorado. NOTF.: AI.T, CnNTRAC.TOR YF•HIC,T,F,"S AND DF,I,IVF,R.4 FOR CONT.RACTO.RS SHALL NOT BE PARKED IN THE FIRE LANES AT ANY TTr19F,', .4 (.'TTY TRAFFIC SIIMMnNS W/7.T, BF, LS.SUF,D AND TI-TF, VF,HICI,F, WILI, 8F, TnWF,D AT TNF, OWNF,RS F.XAF.NSF.. Demolition• 1. Plans shaU be subuutted to the Fize Distxict for the following; • Change orders for the approved submiued plans. 2. All consh'uction dumpsters shaU be a minimum of 20 feet form any shructure_ 3. All Fire Lanes shall remain clear of construction vehicles at all rimes of construction. 4_ All Fire Alarms shaU *pmain in-service while work is being performed. The Fire District shall be notified of any shut down of these systems. 5. A required fire extinguisUec' with a mini,,,mn rating of 2A4013C shaU be within 10 feet of alI `HOT WORK OPERA'ITON". 6. All doors off of the raYed comdor shaU have self-clos2ng doar devices- 7. All fire caulking shall be the depth of the apening. 8. An emergency phone shall be supplieci by the General comactm for joh site emergenoies. 9. AU inspections sha11 be scheduled throwgh the Fire District and the City BwUding Deparba►ent A minimum of 24 Hour notice. 10. All keys to rooms shaU be supplied to the Fire DistricE far the required Knox Box. (Mas6er keys shall match existimg.) May, 31. 2001 3:18PM WHEAT RIDGE fIRE D?S?R'.CT No. 0589 P. 3 11.'I7ae Life Safety Code shall be adhexed to at all times. (For copies contact me at the Fire District) 12.The Fire District shall be notified during all rough-in inspectious and final inspection with a 48 hour notice before. Construction 1. Plans "l be submitted to the fire district for appmval and permitting of the fixe alarm additions. (No plans have been submitted to date.) 2. All "HOT WORK" operations shall have a required fire extinguisher with a minimum rating of 2A40$C within 10 feet 3. Plans were not to scale when submitted and may be subject to changes during the required raugh-in inspection. 4. A mugh and final inspection is to be scheduled with che Fire District prior to a fmal C.O. 5. All electrical panels sbiall be clearly marked w,ith the area of service within the panel. 6. All emergency lighting shall be battery backed up and cover all paths of egress. (This aLso inonrporates the hasemeIIt area.) pnY quesquos regm+diag this plan review please conrtact the Fire District or myself. ~-~9 3a Fire Marshal Fire Cade Inspecbor # 50838f38-66 . ~ `M Y. _ fi`~y r` ~ • _ _ . l ~ b~ k R t 4V 0- ax~,~r t CO) I , ~ ~ ~ . I f ~ A3'f (n ~ t~ _ cc . ~ G V P} y Q ' y< i • y~P' ~y ; ar ~ . ~ ~ ~ • ~ y f ~I ~ W Q s ~ I ~ ~ m Wf: 4Y ' ~ s r y t r^ J ~ cw~', f ~ SL ~ R R) ' < (G ~ ~ ~~yy,, i to ;ef ~ r~ 11~ x ~ a`"~.1, a rEy `O ~ n 3 - 2Q ~ ~ O o eo o.a =n aL - OM - . . ' . ~ • - - ~ - ~ - I . ~ . _ ( ° r - COMMUNITYDEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: Westem Center Property Address : 7615 W. 38th Ave., Ste. B109 Contractor License No. : 21503 Company ; KUNZ & ASSOCIATES Building Permit Number Date OW NER/CONTRACTOR SIGNATURE DF U N DERSTAND W G AND AGREEMENT I heretiy certify that the setback distances proposed by thispermit application are accurate, and do not violate applicable ordinances, rules or regulati ms of the City of Wheat Ridge or covenants, easements or restrictions of rd; th a f ineasurements shown, and allegations made are accurete;tliat I haveread and ag ee tbXel II conditions printed on this application, and that I.assume full res ili ~ ce with theWheat Ridge uildiyg Code(U.B.C.)andallotherapplicab'~ ~ ea i cGs,fbr workunderthis~rmitl a s, (OWNER)(CONTRACTOR)SIGNEG, - /I/l1 DATE I ~ ~ ~ Description : Interior demo of Suite B109 Phone : 18281 1 /20/2005 Phone : 431-5196 Valuation : $500.00 Permit Fee : $30.55 Plan Review Fee : $0.00 Use Tax : $9•00 TotaF: $39.55 Use: BUILDING DEPARTMENT USE ONLY Approval : Zoning : Wiffieda Comrrients Approval : vr., s xx a nv.~rrav ~,~"1W o+,r k KC o m m e m ts~ Approval ; Occupancy ; Walis : Roof : Stories : Residential Units : Electrical iicense No : Plum6ing License No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : (1). This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations andBuilding Code of Wheat Ridge; Coloiado or any other applicable ordinances of lhe City.. (2) This permit shall expire if (A) the woiic authonzed is not commenced within sixty (60) tlays from issue date or (B) the building authorized is suspended or abandoned for a period of.120 days. (3).. If this permit expires, a new permit may be.acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year: If changes are made orif suspension or abandonment exceeds one (1) year, fuli tees shall be paid for a new permit. (4) No work of any manner shal6be done that will change the nalural9ow of water causing a drainage pmblem. (5) Contractor shall notify the Building Inspector lwenty-four (24) hours in advance for all inspections and shall recei4e wriHen appioval on inspection card before proceediing with successive phases of ihe job. (8) The iss a ~per ' e appm drawings and specifcations shall not be construed to be a permit for, nor an approval of, any violation of [he prvlsio ~ e ing cyydes or a rdinance, law, rule or regulation. :ri.: ~j'_... ChiefBuilding Inspector Please sign Terms and Conditions on reverse side of page. CERTIFICATE OF OCCUPANCY City of Wheat Ridge 7500 W 29th Ave Wheat Ridge CO 80033 Permit# 070519 Issued: 07/17/07 Stipulations: Tenant Finish for doctor's office This certificate verifies that the building constructed and/ or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code and development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. Site Address: 7615 W 38TH AVE Parcel Number: 39-233-21-030 Owner: Rocky Mnt. Foot & Ankle Center Contractor: Scott Burcham Colorado Tnterior Finishes 6127 Union St. Arvada, CO 80004 For the Following Purpose: Comm. Tenant Finish Code Editions NO change shall be made in the USE of _/2003 ICC/2005 NEC this building without prior notice 2003 TCC/2002 NEC and a new Certificate of Occupancy 1997 UBC/2002 NEC from the City of Wheat Ridge. Sprinkler System - li 4un hiefBuildnspector g mi i rator CERTIF ATE MUST BE POSTED BY FRONT DOOR OF COMMERCIAL OCCUPANCIES INSPECTION RECORD 7500 W. 29th Avenue Wheafi Ridge, Colorado 80033 (303) 235-3855 ~ /nspection Line (303) 234-5933 Inspections will not be made unless this card is posted on the building site 24 Hours notice required for inspections J Job Address Lc I _ Building Permit No. _O~ Owner V o c ~ ti~ V1-~ r J'~, lc~ r" Issued Type I Occupancy Contractor INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE APPROVAL DISAPPROVAL INSPECTOR INITIALS COMMENTS: Footings/Caissons mwall St e Reinforcing or Monolithic Weatherproof I French Drain Water/Sewer Service Lines POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGN ED Electrical Service h Electric R oug h Plumbing Rou g Air Test Gas Piping Rough Mechanical Insulation Drywall Screw FINALS Electrical 0 Plumbing i Mechanical Frame / Interior Finish Q R.O.W & Drainage vxk_ E),L1/ Fire Department Parking & Landscaping . . **....n.,.,.T.~.inr uucccr_r►nMS /COMMENTS ON BACK IYVIG• /'9VVIIv..r.r..--• - OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED Sez 6Y~er-~ PROTECT THIS CARD FROM THE WEATHER ~ l/ h~ ozr ~ N 7 w0 ~ A O ~ fWwl 1 • O J = N ~ N 6 N fD 7 N a CD ~ 0 ~ ~ N a (D M 0 3 I ~ ~ I -r r A S ~ C- 0 ~ a a N N N J C~ 1 ~ n t O ~ Z ~ `V 0 ~ o ' v ~cn rn a~ O W (D < ~ 7 • 0 ~ Z o ~ ~ O y ~ =F v ~ n < Z c (D o v ~ m I d ~ w~ 0 w~ N 7 W 0n N <o cn W O O W 7 N S N < fD Cr N W 7 3 v n (D C) d 0 ~ ~ ~ y o . ~ 0 3 C/ J C- 0 Q n Q a 'm N N Q ~ / $ C O m Z Mi n (D W 3 ~ 0 Wv)°m O W (D ~ 3 N r Zcny ~ 0 r* ~m z 0 y ~ CD ~ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5953) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: Property Address : Contractor License No. : Company : WESTERN CENTERS, INC 7615 W 38TH AVE B-123 Building Permit Number Date : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permitapplication areaccurate, anddo not violate applicable ordinances, rules or regulations of the City of W heat Ridge or covenants, easemenls or restrictions of record; that all measuremen sBown, and allegations made are acwrate; tBat Ihave read and agree to~a7h7 ide by all co ons printed on thisapplication, and that I assume fullresponsibility fy~j~ompliance the Wheat Ridge Building Code (U.B.CJ and all other applicable Wfieat fjI'j~gg ordinan , for work under thispermit. NNER)(CONTRACTOR).SIGNEDy~I~~~~~~~/A _2DATE fJJ- fT'-0-fl Description : REMOVE (2) NONBEARING PARTITION WALLS ~onln.g Comrr~er~t~~~ Approval : Zoning : B~~Idin`g$Corrim:enfs;~ Approval ; CR Approval : Occupancy; Walls Electrical License No : Company: 18330 2/7/2005 Phone : 306-1000 Phone : Valuation : $500.00 Permit Fee : $30.55 Plan Review Fee : $0.00 Use Tax : $9.00 Total: $39.55 Use : CO 8~ s BUILDING DEPARTMENT USE ONLY OK. 2I7I05 Roof Plumbing License No : Company: Stories : $IC : Sq. Ft. : Residential Units Mechanical License No : Company: Expiration Date : Ezpiration Date : Expiration Date : Approval : Approval : Approval : (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the Stafe of Coloiado and to lBe ZoningRegulations and Buiiding Code of Wheat Ridge, Colorado or any other applicable ordinances of tNe City. (2) This permit shali expire if (A) the work authoriied is not commenced wilhin siMy (60) days fmm issuedate or (B) the 6uilding authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount norcnally required, provided no changes have been or will be made in the original plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shail 6e paid for anew permit. (4) No work of any manner shall be done that will change the nalural Flow of water causing a dreinage pmblem. (5) Contractor shail notify the Buiidin9 Inspector hvenry-four (24) hours in advance for all inspections and shall receive wrilten approval on inspedion card before proceediing with successive phases of the job. (e) The issuance of a permi[ orthe approval of drawings and specifcations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulatioa . Chief Building Inspector Please sign Termsand Conditions on reverse side of page. - COMMUNITY DEVELOPMENT DEPARTMENT 6uilding Permit Number: o~ W"E"J,~ BUILDING INSPECTION LINE - 303-234-5933 Date: : 'a CITY OF WHEAT RIDGE ~ ^ 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) `°~~a^°° APPLICATION Property Owner. iue_S P.- Yln, G e 1~( Property Address -1 ~ S U_) j f-~-tl-. A. V i5 -5+E iF, t cq Phone: Contractor License No.: / Company- Phone:=5 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback dislances proposeG Oy this permit application are accurate, and Ao not violate aDO~icable ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or r tridons of recortl; that ail meawremenLs shown, an0 allegations made accura at I have read and agree lo abide by all conditions Prin[ed on Nis appc~fio nd that I assume full responsibility (or compiiance wiM the Whea ~d e Bui g oCe (U.B.C) and all other applipble W heat Ridge Ordinances, rk~n er is peoit. Description: Sq.Ft.added Z_ / Value:$ Permit Fee:$ Plan Review Fee:$ Use Tax;S. TOial:$ Expiration Date: Expiration Date: Expiration Date: ApProvaP ApProval: ApProval: _ (1) This pertnit was issued in acwrdance witli the provisbns set foM in your aDW~mtion and is suDjecl to the laws of the Siate of Cploratlo and to the Zoninp Regulations and BuiMirp Codes oi W heat Ridge, Colaado or any other applipble ordinances of the Ciry. (2) This permit shall expire if (A) the work auMorized is not commenced within sixty (60) Oays from issue Cate w(B) the building authorized is suspe1Med a abandoned fa a pariod of 120 days. (3) If this permit expires, a new permit may be acpuired fw a fae of onMalf 1M amount nortnally required, proviAed no ciianqes have baen or wiil be made in the oripinal plans and spadfiptions and any suspension or abandonment has not exceeded one (1) year. If changes have been or "rf suspensbn or abandonment ezceeds one (7) year, lull fees shall be paid (or a new pertnil. (4) No wwk M any manner shall be done that v+ill chanpe the naW21 flow of waler causing a drainaqe proWem. (5) ConUaclor shall nodty the Buildinp Inspecior Menty-four (24) hours in advance (w all inspections and shall receive written approval on inspection prd before p/ooeedin9 vnth successive phases oi the job. (6) The issuarroa of a pertnil a tlro apprvval of tlrewings and apedfications slWl'wt De consWed W be a permil for, rror an approval 01. any violation of the provisions oi the building codes a any oNer ordinance, Ww, rule w regulation- Chief Building Official ElecVical License No: Plumbing License No: Mechanical License No: Company: Company: Company: KUNZ & ASSOCiATES WILMORE CENTER 11445 W 1-70 FRONTAGE RD LEID AGENCY EXPANSION WHEAT RIDGE, CO. 80033 7615 W 38TH AVE UNIT B 109 303-431-5196 WHEAT RIDGE, CO. 80033 SCALE 114"=1, PROPOSED FLOORPLAN KUNZ & ASSOCIATES WILMORE CENTER 11445 W 1-70 FRONTAGE RD LElD AGENCY EXPANSION WHEAT RlDGE, CO. 80033 7615 W 38TH AVE UNIT 8109 303-431-5196 WHEAT RIDGE, CO. 80033 SCALE 114'=1' IXISTING FLOORPLAN COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AYENUE WHEAT RIDGE, CO' 80033 - (303-235-2855) PropertyOwner: WESTERNCENTERS,iNC Property Address : 7615 W 38TH AVE Contractor License No. : 21503 Company : KUNZ & ASSOCIATES Building Permit Number : 18291 Date : 1/24/2005 Phone: Phone : 431-5196 OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this peYmit application.are accurate; and- do not violate applicable ordinances,. rules or regulation of the City of W lieat Ridge or covenants,.easements or restrictions of reco that all as rements shown, and allegations made are accurate; thaf I have read. gr,~ to abtde y conditions printed on this application, and thatJ assume full re pons .iityf~- p ia ce with the Wheat Ridge Building Code(U.B.C.) and all otfier applicab ~y~V t i ~ di ~ ces, for work under~this erm' . (OWNER)(CONTRACTOR)SIGNED~ ~ _DATEG , , Description : TENANT FIMH & ~ hs~ . ZoAn;ing~C~~o~rr~„e„n, s Approval : Zoning : ~ ~ =F ~ 0~~~~'~~;~~~ Approval: CR Co~rn m`e~'ntsl, Approval : Occupancy: Walls Electrical License No : 20655 Company:J-Hawk Electric Expiration Date : 5/10/2001 Approval : Valuation : $7,000.00 Permit Fee : $181.10 Plan Review Fee : $117.72 Use Tax : $126:00 Total: $424.82 Use: LQa BUILDING DEPARTMENT USE'ONLY SIC : Sq. Ft. : OK W/ NOTES. SEE F.D. COMMENTS Roof : Stories : Residential Units : Plumtiing License No :18490 Company rBuccino Plumbing- Expiration Date : 1 /10/2006. Approval : OKIKS Mechanical License No : 17013 Company : MAJOR HEATWG & AIR COND. Expiration Date : 8/5/2005 Approvaf : OKIKS (1) This permit was issued in accordance with the provisions set toAh in yopur application. and is subject to the laws of lhe State of Colorado and to the Zoning Regulations.andBuildingCodeofWheatRidge,ColoradooranyotherapplicableordinancesoftheCiry.. (2) This permit shal(expire if (A):tfie work authoriied is not commenced within sixly (80) days fmm issue date or (B) the buildin9 authorized is suspended or abandoned fora period of 180 days. (3) If this permit expires, a newpermit may be acquiPed for a fee of one-half the zmount normally required, providedno cfianges havebeen or will tie made in the original plans and specifcations and any suspension or abandonment has not exceeded.one(1) year. If changes are made or if suspension orabandonment exceeds one (1) year, full feesshall be paidfor a new pertnit. (4) No work of any manner shall be done lhat will chznge the natural Flow of water causing a drainage problem. (5) Conlractor shall notifythe Building Inspector hventy-four (24) hours in advance for all inspections and shall receiye wriNen.appmval on inspection card before: proceednngwifhsuccessive -^`ajob. (6) The issuan,,pg'~-o perm the approval o rewings and specifcations shall not be construed to be a permit tor, noi an appmval of; any violation of the proms srre b tl{ng c des o er ordinance, law, rule or reguiation. ~ " v Chief Building Inspector Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: o~ W"E'",~ BUILDING INSPECTION LINE - 303-234-5933 Date: o CITY OF WMEAT RIDGE " 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235•2855) APPLICATION PropertyOwner: k^ S7`-2P 1" ele /~-f- 'e7Z S,l NL Qao' Property Address: 7~O / S ~v 3tJ' i¢ fie- (g03~ 3 0~-r 13 - 472-3 Phone: Contractor License No.: M1`1201a Company: ~ ~ Phone: 7,2t9 OWNEH/CONTR4CTOR SIGNATURE OF UNDERSTANDING ANU AGREEMENT V alue:~ '-'(7~• ° I hereby certify Nat the utbadc distances Droposed by this permit appliption are P it F accurate. antl eo not vioiate aDWicaDIe ordinances, rules or regulatbns of ine Ciry of erm ee W heat Ridpe a covenants, easemenis a restric0ons of record; that a11 measwements p~yn Review Fee: ~ shown, and aliegations made are aGCUrale: Nat I have read an0 agree lo aDide by aIl conditions printed on ihis application and ihat I assume full responsibility fa jjSe'I'yX'$ compliance with Me Wheat Ridge Building CoGe IU.B.CJ anA ail other aODlipble T lS Wheal Ridpe Ordinances, for work under Ihis pertniL 013 (oW NEfiMCONinACTON)-. (OWNFAHGOMAAGTO(i):PRINTEO DATE Description: (Z e/ti1 O 1/-2 9(~ h' Ff 7~~! , Sq. Ft. adMd BUILDIIr'G DEPARTMENT USE ONLY SIC: Sq.Ft.: ~ pNING COMMENTS: Approval: Zoning: ~ C01.NIENTS: Approval: WORKS COMAiENTS: Approval: Walts: Roof: Stories: Residential Units: Elactrical License No: Plumbing license No: Mechanical License No: Company: Company. Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) Thia pennit waa isauetl in aaadanoe wiUh ttro povisims set foM in your appGOtion and is suDjaU to the Uws of me SUte of Cobrado and to the 2oninp Reyulations arW BuilOirq Godes of W heat Ridpe, Cdaado a any oCher applinble ordinances o1 the Ciry. (2) TTia pennil shall expire if (A) the work aulhorizeE is rwt commenoed wiNin sinty (60) days hom issue date w(B) Me builAing auNorized is wspeMded a aWn0aie0 for a period of 120 Oays. (3) If tles pamiN exp"xes. a new pemiit may De acpuireA for a fee of one-twtl the airaunt rarmalh repuired, provi0ed no Uanpes have Deen or wiM Oe made in Ihe oriqinal OWns and apetifitations and any susPa^sion a aDandanmenl has not raioeeded one 111 Yaar. II d+an0es have been a H wspension or abandonment exoeeOS one (1) Year, full fees shaE Oe Daid For a new permiL (4) No work o1 any manner shaN be done that will charqe tM nadual flow of water wusiny a drainape proWem. (5) ConVSClor shall raUfy Ve Buildinq Inspector N+Mity-lour (21) hours in advance for ap inspections an0 shall receive written aDDroval on inspecUm car0 belore proceedirq wiM suaessive W+ases of the joD. (6) The iasuarwe of a permit a Ihe approval of Cnwirqs aiW spedfiotions ahall nW be oonsOn+ad to be a pelmit for, nor an appoval of, any vblalion of Ne prnisiona of ttw buil0inp codes a any otl»r ordinance, 1aw, ruk a reguiation. Chief Buil m icial SMONE ~pEiErTOR \v/ I PARiIilONS W4LL5 , SMONE DEiECWk (D AND ELEC//PHONE ROOpA FLOOR PLAN: 1 /8" = 1'-0 I DESCRIPTION OF WORK THIS PROJECT CONSISTS OF 7HE REMOVAL OF (2) NON-BEARING PARTITIONS, REPAIR OF WALLS AND FLOORING AND REPAINTING OF THE ENTIRE SPACE THIS SPACE WILL BE USED W CONJUNCTION WITH THE ADULT DAY CARE FACIUTY IN IMMEDIATELY ADJACENT SPACE TO THE EAST THERE IS NO CHANGE TO BASIC ~ HVAC, ELECTRICAL OR PLUMBING SYSTEMS IN THE FACILITY. WORK IN THESE 1 ~ ~ -0 S AREAS WiLL CONSIST OF MINOR READJUSTMENT OF PLACEMENT OF RXTURES ~'AND DEVICES DUE TO THE NEW LAYOUT OF THE SPACE. ~ I Wm G_ Laldry Jr. Nikolay Custom Frame TENANT FIISH ~AN c. Architect CGY1tYaCtOt" BALDRY, JR ~ ~oos4~~~ cai~den~co ao4oz 720.940.4659 ~615 W. 38TH A~E 'epA~ pn:72o.z96a95g UNIT B-123 (203) 2 06 -100c) l/vl; S T t_ R tv c t- i\/ T'i_= of WHEq COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number. ~ BUILDING INSPECTION LINE • 303-234-5933 ~ Po CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE V WHEAT RIDGE, CO 80033 • (303-T35-2855) APPLICATION Property Owner: Property Address: Phone:L6/✓ Contrac[or License No.: r ~ Company: t<" Phone. OWNER/CONTRACTOR SIGNATURE OF UNDERSTANOING ANO AGREEMENT I hereby ceRi(y that the setback disfances proposed by this permit appliqtion are . VaIUC:$ ~`-<-Y-• accurate, and do not violate applicable ordinances, rules or regulations of Ne Cityof PCL7111Y FCC:$ W heat Ridge or covenanLS, easements or restrictions of record; that all measurements shown, and aliegations mad are acwrate; l~at I have read and agree to abide by all Plan Review Fee:$ conditions printed on fhis plicaGOn ndtha I assume full responsibility for compliance with the Wheat idge B' ng o e(U.B.C) and all other applicable ITSB T3 'R Wheat Ridge OrtlinancetT- ~ ~vork u de thi rmit. Total:$ (OWNER)(WNTRACTOR):SIGN~ 4~l DATE 1~~ 1 r (OWNFR)(CONTRACTOR):PRINTE~'j J DATE Description: Sq. Ft. added C ~ SUILDING DEPARTMENT USE ONLY COMMENTS: APProvaC - : Zoning: JG COMMENTS: ~ Approval: xQ'4 T -j e i WORKS COMMENTS: Approval: ancy: Walls: Roof: Stories: Residential Units: N• . 5~fci~~. ~ ~ --si>", Electrical License No: Company:-4;o...< 1 -1 vic Plumbing 1 ~ai3 License No: ° Mechanical License No ~ Company r~,.,~< Company: i 0 Expiration Date: Expiration Date: Expiration Date: ~ ApProval: Approval: ApprOVal' (1) This permit was issued in accordance with the provisions set forth in your applicatlon and is subject to the laws otthe State of Colorado and to the Zoning Regulations and Building Cotles of Wheat Ridge, Coloredo or any other applicable ordinances of the Ciry. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this pertnit expires, a new permit may be acquired for a fee of one-halt the amount normally required, provided no changes have been or will be maCe in the original plans and spedfiwtions and anysuspension or abandonment has notexceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No vrork of any manner shall be done that wiil change the natural flow of water causing a drainage problem. (5) Contractor shall notity the Building Inspecbr twenry-four (24) hours in advance for all inspections and shall receive written approval on inspection carC before proceeding with successive phases of the job. (6) The issuance of a pertnit or the approval of drawings and specificatlons shall not be consWed to be a permit for, nor an approval o(, any violatl;W7 building codes or any other ordinance, law, rule or regulation. Chief Bu' g icial ~ r. App,katio„DaW ( PermitNO. Wheat Ridge Fire Protection District P.O. Box 507 • 3880 Upham Street • Wheat Ridge, CAlorado 80034-0507 , 303-403-5900 Office • 303-940-0350 Fax • www.wrfire.org . , Mame: A9enC Address: Phone: ; W"24-1,.I amnt tln-alw" LMonaaFlon to bR , po~aty W tM M~LpatWNpe Rne AomeCbn . taAmed da~ af anf' P~k P~ 'apwanptMneNd ~r WMatW~e:Rro~ m ~r si~nat„re af Applkanc: I , iVOT1CE: Vcens3rucUon o staz ar~crion er Fn R~t'~kpqarllnsm4.- , m' : a ~ o aqd fewee nb IMps~ian camvw~o. ,~a nb F« sd0WIa. na. psnntt+s m. ~ sLbjeR to ~au eartained Aerein. Upon nry h0ure d aay aontlitlen intludiny rn . naaress: ~ . / r* ,~usiness: L X C.Ontad: . P,,~: to bng !~e~Ee `eroutlon aM the P~ muR Ee reeirneA upoa Axoind to a to ~ a perml~ Nmes tlha normal fee wiN be a~. DLSTRICI" REQUIR~? ❑ NO fl1 , ---x~CrepAYediuper~,nremtWnun Ca1sF,adowaceat3R9~lQ~.'~2 . ~ ~ ~ ~ 'i , . . . . , a . . . _ . . . ~:~,,.u~ E OF PERMIT FORMULA (sa tce sd~eaae shxq FEES ank ` n ' Na ~ Tanks= A~arm Sysbem ns Sysbem Value= Plaris ' Sysaem Value= , ' lfisc Systcm ~ m Va - Rc~ew~' Plans Va~uaeon= Speciaf Ma~uiarg o' Lke Plans Valuation= TOTAL FEES DUE . O 0 TotalBidg: D Afteration 0 New 0 Pattial KJ.ba~~ r i ~G'A • M S~ , Fieki Inspe~au ad [~es' Q ~ ~ ~ . ~r..: ~ H~o~aLlcTests and Dats t , v com~s:, ~ ll~Se~r~ent " ' dSiEes'• Mile "tfiNoiftB, inbr tw~.e m . , . ~ fieteg x Nn. rf Hnrs. ~E' , s . w , w accura0e. I4wa faoNvad Dytridt and b hEiled WHEAT RIDGE FIRE PROTECT[ON DISTRICT PO BOX 507 • 3880 UPHAM STREET • WHEAT RIDGE, COLORADO 80034-0507 303-403-5900 • FAX 303940-0350 • WWW.WRFIRE.ORG Kunz & Associates February 17, 2005 Larry Kuntz 11445 West I-70 Frontage Road Suite A Wheat Ridge, Colorado 80033 Re: 7615 West 380' Ave., tenant finish. The following requirements aze made under the 2003 Intemational Fire Code adopted by the City Council of the City of Wheat Ridge, Colorado. 1. Emergency lighting shall be provided for the main egress ha11 ways as well as the bathrooms. 2. Illuminated exit signs shall be provided at all entry doors. 3. Signs shall be affix to the door stating " THIS DOOR TO REMAIN UNLOCKED WHILE T'HE BUILDING IS OCCUPIED." 4. A required Fire Extinguisher with a minimum rating of 2A-40BC shall be mounted within 75 feet of each other. (T'his tenant shall have a minimum of one.) 5. A required extinguisher shall be supplied during all "HOT WORK" operations. 6. A required mugh in inspection shall be scheduled with the Fire District. 7. A Building permit shall be obtained from the City of Wheat Ridge and posted at all times of construction. 8. Any changes to approved plans shall be submitted for approval. 9. Any fire alarm system shall be approved by the Fire District. Any questions please contact me at the Fire District. Res tfull submitted, /:7 Do as J. Saba Fire Marshal Feb.10. 2005 4;01PM WHEAT RIDGE FIRE DISTRICT No.4001 P. 3 WHEAT RIDGE FIRE PROTECTION DISTRICT PO BOX SO% o 3880 UPHAM STREET • WNEAT RIDCiE, COL,ORADO 80034-0507 303-403-5900 • FAX 303-940-0350 • WWW.WRFIRE.oRG City of Wheat Ridge, Colorado February 3, 2005 Building Department Chad Root 7900 West 29'h Ave. Wheat Ridge, Colorado 80033 Re: 7615 West 38th Ave. Units B 109-B 107. There are several fire code issues tUat will be addressed upon submittal to the Fire District for permitting and plan review. Note that there is inadequate information from the submitted fax to the City of Wheat Ridge. I will need to see the entire building and the entire scope of work. Please contact me if you have anything fiuther. Submitted Dou as J. Saba Fire Marshal COMMUNITY DEVELOPMENT DEPT W"~TR,T Inspection Services Division (303) 234-5933 Inspection line (303) 235-2855 Office °Rp CORRECTION NOTICE ❑ Elec. ❑ Plumb. ❑ Mech. ❑ Structural ❑ Other ❑ 1st ❑ 2nd ❑ 3rd Job Address: rn,, :s T r ; ; t p7 ❑ Re-inspection fee of $ must be paid prior to re-inspection. ❑ Blocked Access o No one available forarispctri4: Time s AM/PM 'When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: , DO NOT REMOVE THIS NOTICE Fe6,10. 2005 4:01PM WHEAT RIDGE FIRE DISTRICT COMMUNITY pEVELOPMENT pEPART11lENT BUILDING INSPECTION UNE - 303-23C-5933 CITY OF WHEA7 RIDGE ` 7500 WES7 29TH AVENUE WHEAT RIDGE, CO 80033 • (303-235-2g55) APPLICA: Properry"Owner:,~es{-e~,,.. C~~+~v5,~.~c' • No.4001 P. 4 8u0ding PermR Number. Date: c~a PraPenY AddrC55=, 6! 5 i S j! G a 4 Ql- n Cmnetor License No.: COmpa°y'•!C..~.,z 4 A'SSGClII.rYt^_ ~ PI10flt:3Ui ~l? 1 S I~:f OWNEWCONMACTOR SIGNANRE Of UNDRRSTANDW G ANO AGRMUVM7 I Acrebytd5lythat emuate, arid do no wheat f3dgs orea+ slwwn, antl aGegatie tzindid" pcmtw I Wlteal RIOgE O'rdirv DescNptlon: r I sq.r3addee rJ coMMFxrs: APAroval: ' 2oning: $ 2801 JGCowMEnrrs: „d d,/fl'µ /'Jo*esIP~J40~~' - Approval: [.~~~_f 64, ~vff~y woaxs ca,warrs: ApProvai: 1 ancy. walts: Roof: Stories: Residential Units: Electriql License Np: ~~`c . Plumbing License No: ro~iV Medtanical I.icense No: I~I oI ~J Comp2ny;.; 1-lawk. cl•, ComPanY• E~tc!L<c(~lv:~•Iriu~ COMPWy.MaJOr i.:o.4-;KS,A4 REkl Expiratlon Date: ExpiraUon Oate: - Expiration Oate: vaL• (1) Tft Dermp rws "sa1N0 in accadana wiM Uie pewione se[ TaM m yourapPHO5on and k aubjeum the laws oi11w Slahe M CAlpado an0 b fe ZoNeD Regulatlom and Budldvg CoOss of Wlfqt Ridpe. CdoraOO w anY oem a00ooeM artlin2non of tlie CTy. (2) Tn's pen,at tnae smYe u(n) n,e wonc aun,wt:m e nan eanmeneea walan svH (go) daYs irom isa,e mts a (B) Ine a,i~eMy aWha'ved b mispedetl or aDandorKd fa a pario0 of 120 dya. ~ • (3) If tl+la Oen'nR a-iec, r nsr psnNtnay4 aoqiwad faa fes W anefiaM Me anaart norma4Y no7uMed. WoKded no tlmnqos harebaen or WI bsmade in meagWl plavs and apsdReoBas yb aoYSwpandon v a6andornnmthas not.ansedeaane (I)Sex. tlGwgaslovsbeeaiaifwspensionaxbordarneNexceedoar(1)Yrar.luUfeosshaNbepaidforenewDoma (d) No wat ot mry manw aAa4 be ebne Ihffi wltl dMys pie naaral 1b.v dwMw cKabg a pryags prppim_ (s) conharmr shao nofiy ma eu7aeiy hxpI uo, wsar4ow (aA) nars in advance ror au :vpections sna anan receive writlen apprmral on enpaWOn are he4ora pronstllnp wm suoeesaMp Ghasss d ur Job. (6) ihe eauanoe oi a permfS or Ne apprord a7 drawinqs an0 epscftations SireO not be wnsM+ed le be a eDD~Oral oF. any violG6on d tl~s of Me 6ull~ oodea w Pe+m§ Ser, nor an ~9 d'ry W+er ormrwm. lar. nib Or regulaGOn. Cti~ef Bu g icial ''ed bv 4ire psmid aGplieation are . V3jue:$ .440wrepukfioe60flheCYyof p8iID1tFC2:$ ~B of nemrd; 9~at a8 ~n yyi ~ ao~ +oaaaeyan P1anReviewFoe:$ "sp°"'roWp' f°` Use TaY:~ ~-9-C) arM an otl~er appliobb / 0 ! r0[3l:$ /Feb.10. 2005 4:01PM WHEAT RIDGE FIRE DISTRICT . ; CORR/DOR I 3'-11 " 4FFlCF RESTROOM Y No.4001 P. 5 OFFICE ! VACqNT S111TE B~ ~D AGENCY UN?8f07 ' UNITBIOB Wheat Rki9e B Department Ap IXlSTlNG FL • 'E d apemiR Q~ppad d pkr,, ~pw~rr~lpit u~d eAelnatheapsml~xvanappo gi~b srydtliepwi+ionsdMebdd~gmdeardary e~~ '~°~P~^D b 9~ ~Y to NamNausel Ihe poYi~lp~d/r kUNZ & ASSOC/A'I'FS ~~~s dlhe GIy dmf op~ ae pid 11445W1-I0FROMAGERD LEIOAGENCYIXPAN510N I*fE4T~E 00• OWM 7895W38THAVEUN?8109 30-437'3196 WNEAT RlDGE CO. 80033 Feb.10. 2005 4:01PM WHEAT RIDGE FIRE DISTRICT r- a.oser 14'-5m OFFICE No, 4001 P. 6 20 =9" • :AC- W RESTROOM ' vncavrsurrE • UNlf 6107 ~b ~PROPOSED FtOC 4 7'-4' ~ RPLAN KUNZ 8 ASSOCIATES WlLMORE CENTER 11445W 1-70 FRONTAGE RD LElD AGENCY EXPANSION N?fEA7FtIDGf,C0.80033 7815lN38T)iAVEUNlTB109 3034315198 WHE4TRIOGE, E0.80033 808 LElD AGENCY UN?B109 scALE va =r ~I ; I I Certi~"icate of Coynpletion And / Or . Coynpliance City of Wheat Ridge 7500 W. 29`" Avenue Wheat Riclge, Colorado 80033 THIS CERTIFICATE VERIFIES TfIAT THE PROPERTY DESCRIBED BELOW, DOES COMPL7' WITH THE WHEAT RIDGE BUILDING CODE, ZONING AND OTHER RELATED LAND USE AND DEVELOPMENT LAWS OF THE CITY OF WHEAT RIDGE FOR THE FOLLOWING PURPOSE. PERMIT #18291 Tenant Finish Dctte: 3/17/20T ~.5 Owner: Wectern C'e.nteA 7nc OwnerAddress Z615 W 38'~ Arr #107-104, WbrLztl2idg.v,, Cn 800-3.3 PYOpeYty Adds'est: Sa.mr Contractor: Kunz &Associates ContractorAddress: 11445 W. 1-70 Fr_ Rdy Wheat Rid_ae. C;n 80033 ChiefBuilding Officiul: Zonine Administrator. • ' j ~ / INSPECTION'RECORD 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 (303) 235- 2855 cv-Insoectfon Llne (303) 2345933 Inspections will not be made unless this card is posted on the building site 24 Hours notice required for inspections Job Address ^e . 6 1) - 1 U T ~ Buiiding Permit q Date Issued C~ Type Occupancy Owner 0 • Contractor a-1A z -a < > Contractor Address ;'/yUS 7c) INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE APPROVAL DISAPPROVAL INSPECTOR INITIALS COMMENTS: Footings/Caissons Stemwall ReiMorcing or Monolithic Weatherproof! French Drain WatedSewer Service Lines POUR NO CONCRETE UNTIL A80VE HAS BEEN SIGNED CONCREfE SLAB FIOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) DO NOT POUR FLOOR UNTIL ABOVE H AS BEEN SIGNED Elec6'ical Service Rough Electric Rcwgh Plumbing m b Air Test Gas Piping Raigh Mechanical Freming d ~ Roo~ing Insulation r Drywall Screw -lv- y Fiwws GY' ~ Electrical -c~ o 1L Plumbing .17 S ooL Mechanical _y- ~ a ti ~ J Freme / interior Finish .1 p k R.O.W & Drainage ~ Fie Department 1 73 Parking 8 Landscaping "'"NOTE: ADDIT IONAL IN SPECTIONS / COMMENTS ON BACK ~ ~k OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED !~L PROTECT THIS CARD FROM THE WEATHER 9 N a 1 w~ 07 w i~ ~ w0 A p w~ w O ~ ~ s < m Q CD CD :3 v a (D ~ d 0 ~ ~ y 9 0 ~ ~ N C- 0 Q a n P ~ a N l / SG y ~ ' , -1 r Q ~ U 0 ~ )e i r n O 3 3 n ~ C O ID Z (D W~ ~ ~ ' (D G " N m ~ • c~ ~ Z c~n N ~ 0 0 0 ic m ~ = 0 . < N z ~ 1 (D °m ~ w::E oS w(D N 7 w0 A p t~0 N W O W O 7 N S < (D Q N (D 7 3 v a CD 0 ~ 0 ~ = ~ N > a CD 0 ~ 0 C- 0 a D a a a N N ~ r~ ~~i ~ (D n ~ 0 n .WJ = n ~D ~ N ~ (D n 0 0 3 W N W N , ~ ~ N~ ~m N N v < y O ~ 0 0 ~ ~ C Z ~ v < m r ~ ~ m z ~--I m ~ -i Certi~"icate of Coynpletion And / Or Coynpliance City of Wheat Ridge 7500 W. 29Avenue Wheat Ridge, Colorado 80033 THIS CERTIFICATE VEAIFIF,'S THAT THE PROPER7YDESCRIBED BELOW, DOES COMPLY WITH THE WHEAT RIDGE BUILDING CODE, ZONING AND OTHER RELATED LAND USE AND DEVELOPMENT LAWS OF THE CITY OF WHEAT RIDGE FOR THF, FOLI,OWING PURPOSE. PERMIT #17515 Tenant Finish # B-I15 Date: nctnher 12y 2,004 Owner: West.rn Cnt rc Tn OtvnerAda'ress. YIA Properly Address: 7~i 15 W 3V A v#R-11 ~ F~~+ nidg,~ Cn 8002 3 Contractor: Tiuobs Construction Co ContractorAddress: 5624 S. Ando St,, Auro-ra C'n R007.5 Chief Building Ofj"iciuk - Zoning Administrator: ~ 5 INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 234-5933 INSPECTION RECORD 7- F. JOB ADDRESS > ~LL ~D rJ~ G TYPE OCCUPANCY 164- BUILDING PERMIT N0. DATE ISSUED J s OWNER CONTRACTOR SETBACKSFROM PROPERTYLINES: NORTH SOUTH EAST WEST INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB INSPECTION DATE INSPECTOR Foundations Foatings Caissons Reinforcing or Monolithic Weatherproofing POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor: Electrical (Ground Work) Plumbing (Ground Work) Heating (Ground Work) DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED Rough Electrical - ~ Rough Plumbing Air Test Gas Piping Rough Heating & Ventilation raming Fsulation I Drywall Nailing Roofing Refrigeration Electrical Underground o' Final Electrical Zq- o - Plumbing - Heating & Ventilation Frame IP tvv V;)c, OL~G- lo - l2-o%F a R.O.W. & Drainage Fire Department Q / Parking & Landscaping p1L C-a n, I l O' 12. -b ~ OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 17681 BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE Date : 9/10/2004 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: CLEAR CREEK FAMILY PRACTICE Property Address : 7615 W 38TH AVE Phone : Contractor License No. : 19332 Company : AMERICAN SIGNS & GRAPHICS, INC. phone : 932-8477 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify ihat the setback distances proposed by this pertnil application are accurete, and do not violate applicable ordinances, rules or regulations of the Ciry of W heat Ridge or covenants, easements or restrictions of record; thataL[ surements shown, and alle8atlons made are accu2te; that I have read anQag e tro abide by a nditions printed on this appliration, and that I assume fu!~~ ponsibifg..~°^~^~wit t~st Ridge Building Code (U.B.C.) and all other applit~67e-VPfiea Ri~g 9i ~ , for work under this permit. (OWNER)(CONTRACTOR) SIGNED - DATE Description : PAN CHANNEL SIGN. 60 SQ. FT. Construction Value : $4,000.00 Permit Fee : $126.50 Plan Review Fee : $0.00 Use Tax : $48.00 Total: $174.50 Use: X BUILDING DEPARTMENT USE ONLY . p~rLi ents': Approval : TRC Zoning : PCD Bu rgents:'; Approval: Approval: Occupancy: Walls SIC : Sq. Ft. : OK ANY ELEC. MUST MEET 2002 N.E.C. Roof : Stories : Residential Units : Electrical License No : Company: Expiration Date : Approval : Plumbing License No : Company : Mechanical License No : Company: Expiration Date : Approval: Expiration Date : Approval: (7) This permit was issued in accordance with the provisions set forth in yopur application and is subject to ihe laws of the SWte of Colorado and to the Zoning Regulations and Building Code of Wheat Ritlge, Coloredo or any other applicable ordinances of the City. (2) This pertnit shall expire if (A) the work authorizetl is not commencetl within sixry (60) days from issue date or (B) ihe building authorized is suspended or abandoned (or a period of 120 days. (3) If this pertnit expires, a new permit may be acquired !or a fee of one-half the amount normally required, pmvided no changes have been orwill be made in the onginal plans and specifications antl any suspension or abandonment has not exceeded one (1) year. If chanpes are made or it suspension or abantlonmenl exceetls one (1) year, tuli fees shall be paid /or a new permit. (4) No vrork of any manner shall be done that will change ihe natural flow of water causing a tlrainage problem. (5) Contractor shall notify the Building Inspector lwenry-four (24) houre in advance for all inspections and shall receive written approval on inspection cartl 6efore proceediing with successive phases of the job. (6) The issuance of a permit or theapproval ot drawings and specifications shall not be construed to be a permit tor, nor an approval of, any violation of tha provisi buil ' codes or any`"r ordinance, law, rule or regulation. Chief uildingTns~~ ~ Please sign Terms and Conditions on reverse side of page. -r COMMUNITY DEVEIOPMENT DEPARTMENT Building Permit Number: BUILDING INSPECTION LINE - 303-2345933 Date: Q,J-gy C1TY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235•2855) APPLICATION PropertyOwner. G11-ldr,oR. C#2EE?C /d.2.4rA`cC PropertyAddresr. 96/S W. 3~ S~" U./,71+#Rtt C~a+~dY~ Stl•-'`Ja-//SPhone: 30,~' a72" S1s ,p-1t7 Contractor License No.: Company: Phone: J ~1.ri E~t%c.v~✓ f...r.T 6AeAp1 'cd' 7Zc. OWNER/CONTRACTOR SIGNATURE Oi UNDERS7ANDING ANO AGREEMENT I hereby certiy thal the setback distances Droposed by this permit application are accurale, and do not violate ap0~icable ordinances, rules or regulaGOns of the City ot W heat Ridge or covenant5, easements w restrictions of recad; that all meawrement5 shown, and albqations made are acwrate: tliat I have read and aqree to abiCe by all condilions Orinted on this apDlicaUOn an0 that I assume full responsibiliry (or compliance with Me Wheal Ridpe Buildinp Code (U.B.C) and all er applicable Wheat RiOge Ordinances. (orwork unoe ~ (owrlEapcorrrancroa) .si6NeD-,-*- (OWNERxLONTRACTOR):PRWTED Description: 5a. Ft. added ONING COMMENTS: Approval:~ ~ Zoning: PC~~ BUILDING COrdMEN75: Approval: PUBIIC W ORKS COMMENTS: Approval: cninancv[ W8fl5: Edward Jaconski 5553 S. Yank Ct. Littleton, CO 80127 DEPARTMENT Roof: Stories: Construction Value:$ . Permit Fee:$ Plan Review Fee:$ Use Tax•$ Total:$ Inc ; C~w . , r 2ep4 ONLY SIC: Residential Units: Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval• Approval: Approval: (1) This pemil was issueE in axadance wiM the Drovisions set foM in your application arM is subject to the laws of tlie Stale of Cdorado and to the 2min9 Reguiations and Buildirp CoOea of W heal Ridpe. Colorado a any olher apD~icable ordinances of the City. (2) This permil shail expire if (A) ihe work authorized is not commenced within sixry (60) days from issue Oate or (B) the buiWing autlwrized is wspended w abandoned iw a period of 120 days. (3) I( tlhis permft expiros, a rxw pertnit may be ac9uirod tor a fee o1 one-halt the amounl mrmaUy reQuired, provided no chanpea have been awill be maEe in the oriqinal Pians and specifinlbns and any suspension w aDendonment has rwt exceetled one (1) year_ Ii dwnges have been ar "rf suspension or abandonmenl exceeds one (1) year, lull (ees shall be paid for a new pertnit. (4) No work of any manner shail Oe done ihal wili Cwnge the natural flow ot water pusing a drainage proDlem. (5) Contnctor shall notiN 1M Build^Q I^SD°d°r lwe^tY'four (24) hours in advance for all inspections and shall receive written approval on inspection caM beiore Proceedinp wiM successive phases ot the job. (g) The iswance o( a pemut a the approval of drawinqs arM spedf~cs6ons shall not be conswed lo be a permit tor, nor an approval of, any violaGOn ot the provisions of ihe building cotles or any other orCinance, iaw, rule or regulation. Chief Building Official AMERICAN SIGNS & GRAPHICS /NC. 303-932-847e7ications: Custom Nlanufaccure 24 UA Pan Channel Letters Faces: 3/16`.greeu 2030 faces Trimcap: I" gold Ncon: 15 mm snow iahitc Sidewalls: dark bronze Logo Box: mnsctucecd samc as Ictecrs, 31n transluccnt vinyl on 3/I6" white plexiglas ISmm snow white neon 1vV ~p~ 1D~Y ~I] Y.9 . ~ 24 in : , G, A f ~i~.:~ _ ' 2; s CD :3 0 O -~i N .n. O ~ m ~ < N 6 N ~ v a m ~ ~ 0 , (D ~ N 9 A cz 0 ~ ~ -v ~ 1~4,- ~ ~ _.j C- 0 Q a a 0 N N a ~ n 0 C ~ ~ ~ O :2 m W , • r 0 Z (D o v Z , ~ m ~ 10 COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 77669 BUILDING INSPECTION LINE -(303-2545983) Date : 9/9/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: Property Address : 7615 W 38TH AVE #B-115 Contractor License No. : 22086 Phone: Company : The Aegis Life and Fire Safety Company Phone : 234-5501 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit applicalion are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurete; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Rid9e Building Code (U.B.C.) and all other applicable /W heat Ridge ordinan es, for work under this permit. (OWNER)(CONTRACTOR) SIGNEDC~`.c¢~ V~< DATE Construction Value : $5,000.00 Permit Fee : $144.70 Plan Review Fee : $0.00 Use Tax : $60.00 Total: $204.70 Use: Description : FIRE ALARM SYSTEM UPGRADE. REPLACE EXISTING CONVENTIONAL FIRE ALARM SYSTEM WITH ADDRESSABLE (NON-REQUIRED) BUILDING DEPARTMENT USE ONLY Ko .-..,,,,me _n,~ , or,►~ Approval: Zoning : ~ y A170-OW,, Approval: Approval: Occupancy: Walls sIC : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company : Expiration Date : Approval : Mechanical License No : Company : Expiration Date : Approval: (1) This permit was issued in accordance with the provisions set foAh in yopur application antl is subject to the laws ot the SWte of Colorodo and to the Zoning Re9ulaUons 8nd Building Code o( Wheat Ridge, Colorado or any other applicable ordinances of ihe City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issua date or (B) the building authonzed is suspended or abandoned for a period of 120 days. (3) If this pertnit ezpires, a new permit may be acquired !or a fee of one-half ihe amount normally required, provided no changes heve been or will be made in the onginal plans and specilcations and any suspension or abandonment has not ezceeded one (7) year. If changes are maCe or if suspension or abandonment ezceeds one (1) year, full /ees shall be paid for a new permit. (4) No work of any mannar shall be done that will change the natural Flow of water causing a drainage problem. (5) Contredor shall notiy the Building Inspeclor hventy-lour (24) hours in advance for all inspections and shall raceive wntten approval on inspection card before proceediing with successive phases of the job. (e) The issuance ot a pertnit or the approval ot drewings and specifcations shall not be construed to be a pertnit for, nor an appmval of, any violation of the pmvisions of thecode=e, law, mie or regulation. Chi n speo c Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: SUILDING INSPECTION LINE • 303-2345933 Date: ClTY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEA7 RIDGE, CO 80033 - (303-235-2855) APPLICATION Ptoperty Owncr: PropertyAddress: 76i5- w. 39'« AJ4. Phone: Conuactor License No.: 2, 2 0X6 Company: trKi: A~G~S brF£ dNq F,az s,o-F£ry Phone:3~,3_z 34c-SSm/ OWNEWCONTRACTOR SIGNATUNE OF UNOEPSTANOING ANO AGREEMENT I hereby certity Mat the setback disUnces proposed by this pertnit apPlicaUOn are r rate, and do not violate aDWicable orCinances. rules or repulations of Me Ciry of at RiOpe or eovenants, easements a restrictions of recorA: that yl meawrements shown, aiW allepa6ons made are aca2te; that I have read antl apree to abi0e Dy all cqnOitqna Drinted on thib application and that 1 assume lull responsibiliry /or compliance with the Wheat Ritlpe BuilCinp Code (U.B.C) and alI other applicable Wheat Ridpe Ordinances, frn work untler Nis permil. 1O'+NERNCONTRACTOR):SH',Hm DATE Y 92Z4 (OWNER)(CONTRACTOR):PRINTEO G~FGOa W, L.d~ S DGf`J Descriptfon: Finz 41c41q~ srrrc.M r t/Z { A[4R-^ $YSr£~ Sq. Ft. adMd Construction Value:$ 5-, o°O°=' Permit Fee:S 70 Plan Review Fee:$ Use Tax: Total:$ 705! 7c) v16RApi - /1tNLACF fY,s^,MC- co,'sPro~ ,1L, wIi ff qDU4ESY,t A1L RSQtb+Ax0) Expiration Oate: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This Pamut was fasusd in accwdarwe wim Ca Grovisions sat toM in yow application an0 is auDject a the Wws W me Sute of Cobrado anA b Me Zonirq Reyulatia+s and Buildirq Cotlea of Wheat Ritlpe, Cobntlo w any otlm applicade wAinancea of tne Ciy. (2) Thia permil shaY e:pire H(A) IM work euthaized fs not wmmenced within Sixty (60) Cays (rom iuue tlate W(B) the Wildinp 9uUhoAxetl is wsperWeO a abandonsd for i psnod o1 120 days. (3) I( Ws Dw^il1 eV6es, a naw parmit may W acQuYed tor s Ms of onstWf Ma amounl non^aNY reqw'e0. Wovided no dwVm have bsw awW W m~ds in Ois aqiNl Dyns and+Wdliatbns anC anY aapansion a aDandoivnent has nd exceeds0 ona (1) rear. n chaiqas rwva oeen «it susomsion w aeanaonmerN e:ceeds one (1) vear, fua fees snan ee paiC ra a new vermil (4) No wpk o/ any mambr aha9 be dane tliat will Gwge tlhe nalural 1bw o( wabr rausinp a Crainape probbrn. (5) Conhacfor sh1R rqtifY ft BuildinG MspecW Menb'jour (21) hdrs in a0vince Fa ell inapections an0 stfall raceive writlen aDOrw'N m inspecUOn cW belora pra.+eedirq wiM sueoemve phaaes of ft job. (6) The iswsnce of a pemwt a the appoval of Orawirps arW apeafiwuont shaN not be conatrued W Ee a permd ior. nor an aDDroval 01, any violaGOn of 7ie provisions of Me DuilGinp coCes a any other ordinance, law, ruk or regulation. Chief Buildinp Official Electrical license No: Plumbing License No: Mechanical License No: Company: Company. Company: WHEAT RIDGE FIRE PROTECTION DISTRICT PO BOX 507 • 3880 UPHAM STREET • WHEAT RIDGE, COLORADO 80034-0507 3034035900 • FAX 303940-0350 • WWW.WRFIRE.ORG The Aegis Life and Fire Safety September 8, 2004 Greg Logsdon 1651 Routt Street Lakewood, Colorado 80215 Re: 7615 West 38`h, Tenant finish, Fire Alarm System The following requirements are made under the 2003 International Fire Code Adopted by the Wheat Ridge Fire Protection Dish-ict. 1. The battery for the Fire Alarm System shall be dated with the Month/ year of installation. 2. The alann system shall be tested prior to scheduling any final tests with the Fire District. 3. Updated keys for the alarm system and the suite shall be provided for the required Knox Box. 4. The electrical circuit in the circuit panel for the alarm system shall be denoted with a red switch and/ or marking on the door of the electrical panel. 5. Signs on the front doors shall state "THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED". 6. An N.F.P.A. 704 sign shall be visible in the front window with the required sign for the amounts of hazardous materials in the unit.( Oxygen, etc.) 7. Fire extinguishers shall be provided within 75 feet travel distance from any point in the suite. The extinguishers shall be mounted 3 to 5 feet from the floor surface. Any questions regarding these requirements please contact the Fire District or myself. Resp~tfully s~~ tte ~J ~ I1- Douglas J. Saba Fire Marshal ~ V Apptication Date: Permit No. o- Wheat 6ticlge Fire Prmtection District ~ P.O. Box 507 ° 3880 llpham 5treet • Wheat Ridge, Colorado 80034-0507 ~ 303-403-5900 Office •_303-940-0350 Fax • www.wrfire.org m , _ . "Contractor Infarmation Site Information ^ , • ~ Name: , A{ Z.rf" An1b g'm; sat'is . Address: . . qgent:rLC'G~.rrt'r✓ - f1"~. ' 4v° . , Address: ;tF r • , <~r ' : . r Busmess , Contact: e-a Phone:, Phone: v - IattesC the above +qformation to be acwrate. I have. receivedand. ieviewetl the Inspection Compliance.and the FeeScfiedule; This permit is the property of the Wheat Ridge;Fre Protecdon DisErid and is issued subjectta conditions rnntainedherein. Upon airy failure of any condition including M failure of clearenc¢ of any permit payment, ffiis Oermit is-subject to immediaterevocadon.andthe.permitmustbereWmed upon demand to a : - represenWtiveoftheWheat=RidgeFire ProtectionDisUict, ' . . . . .---.Signature of Applicant: !J^^'- '4,,-~ NO'1ICEeIf const#ucli0tt is started prior#o the issuance of a permit; THREE'(3) Gmes,the normai,fee will6e assessed: ~ INSPECITON BY'FIRE PROTECTION DI5fRICTREQUIRED? - Z4ES' II NO , t'PI PasC-th/spermifinamnspicuausp/ace. RequestrequiradmspedibnsaminimumoftBreedays:inadvanrn.at303-l033502. , j TYRE OP PERMIT. FORMULA lsee fee scheduie sheetp I FEES < ~TankirlsPection iNO.oFTanks=: - ~ _ , ReViewpiarm5ystem.Plans ISystemLalue.= I~f1.P:8)- ~ ~Review Sprinkler Syskem Plans ]System Vaiue= = I I 1 Date Paid JG] j 'Mi c S rri Pl ns IS tem Val Re i t 0 v s ys a ys ue I i ew c e ~ . 1 IReview,Builtling Plans 1ValuaGon= s I I Amt. Paid 1.1el)a . m I ISPeu44 Handlin9 ar Use Plans IVatuation=::: . ~ ( Method. l 70TAL FEES DUE I jld~ 0:f+U I I Initiais I L,/~',' ~ El ToTal Bldy.` 04teration , El New ' ❑-PartiaF ❑ Ottter: ' Fl, Id Ins P~.,... 4 , - _ . . . . _ , . . . . _ . . Comments Fy - ~ . r.,'.-.; . , • . ~ ~ , ! FIRE PROTECTION DISTRICTAPPR VALIS REQUIRED PRIORTOTHE ISSUANCE OFTHI$ PERMlf. El APPROVEDI4S'SUBM ' , . , , . ~ Ll^GiSNDI"fEQNltLL APPROVED (See Cor~men ~ , " DATE F~~` " By ~~,•*;a ~ ' r . . ° ' k . , TP.1E,8F8ERMIT I,''FPRPiUtA(ceefeescheda~esheet), I' PEES I . M SiCe Ass&:~§ment tRe-Su4mittap No: of Sites t6ate Paid I~') ~ I-1PIan Rev'i5ion (Re-Inspect) ~NO. of Hours Amt. Paid { ~ 1. lAfter hours lnspediop 12 Hoprs + No. of Hours Method ] ~ 9-.. TOTAL FEES DUB ' f ~ I, Initlals i PINALAppROYAL ` -1 . BY lITIE DATE' E r , , : r - , . : ~ . . , ,s; . ~.,.L.....z...._ , .d,v.~..u..s '-.'.,,.w..~.: - . ,~,.~.~..i - _.~....M~ ~U...~.. o THE AEGI3 LIFE and FIRE SAFETY CObIPANY Project: Clear Creek Family Practice 7615 W. 38'b Avenue Suite B-115 Wheat Ridge, CO 80033 1651 Routt Street Lakewood, CO 80215 303 234-5501 ~ theaegis@comcast.net Scope: Design, supply, and install one singie loop addressable fire alarm panel. Replace existing conventional iniNating devices with addressable devices. Replace existing non-sync notification devices with synchronized devices. Add smoke detection for control equipment protection. Add notification in common use areas such as lavatories and break room. All devices to be relocated and/or installed in accordance with 2002 NFPA 72, Chapter 4-8 for proper coverage. Gregory W. Logsdon C.E.T. NICET 106046 Fire Alarm Systems / III 4/, r Project Infortnation Project Name: Clear Creek Family Practice Project ID: JCC 38th Prepared By: Greg Logsdon C.E.T. Date: 8125/2004 Ckt. Number. PGM-1/0 #1 Ckt. Name: Notification Appl Circuit Panel ID: 5700 I/O Use: Noer,cation nPW ara,it ~ Qty Device Current Draw Each Standb Alarm Current Draw Total Standb Alarm 3 Wheelock AS-24MCC-FW 15cd 0.000 0.097 0.000 0.291 1 Wheelock ASWP-2475-W 0.000 0.153 0.000 0.153 4 Wheelock RSS-24MCC 15cd 0.000 0.045 0.000 0.180 1 Wheelock RSS-24MCC 30cd 0.000 0.072 0.000 0.072 0.000 0.000 Totals 0.000 0.696 Ckt. Number. PGM-I/O #2 Panel ID: 5700 Ckt. Name: Notification Appl Circuit I/O Use:I NOtirication npW Grcvit ~ Qty Device Current Draw Each Current Draw Total Standb Alarm Standb Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 M project Infomwtion Project Name: Clear Creek Family Practice Project ID: JCC 38th Date: 812512004 Ckt. Number: PGM-IIO #1 Ckt. Name: Notification Appl Circuit Qry Device n %nl6enlnrlr GC_94MCC-FW (1 4 Panel ID: 5700 _1 I/O Use: Notlfiwtlon NPOarcuit r..r.e.,t f)raw Far.h Current Draw 0.000 0.153 0.000 0.153 0.000 0.045 0.000 0.180 0.000 0.072 0.000 0.072 0.000 Ckt. Number. PGM-I/O #2 Ckt. Name: Notification Appl Circuit Qty Device Panel ID: 5700 uo use:I NonficaeMai araric Current Draw Each Current Dr. S~tandb ~ Alarm Standb 0 n nnn I 0.000 .000 IntelliKnighte Model 5700 Single Loop Addressable Fire Alarm Control System ` The affordable addressable solution. IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm ith the revolutionary value and performance of control/communicator system that provides you w y combined with exclusive, built-in digital communication, distributed technolo i g ng addressable sens that includes an wer t easy to use interface. Powerful features such as drift compensation , po intelligen and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-500-446-6444, or in Minnesota, call 763-493-6435. Description ift d • Buitt-in synchronization for liances from GentexO, Faraday, a r The IntelliKnight 5700 performs compensation and calibration checks pp System SensorO and WheelockO. on each of the sensors in the system. . guitt-in annunciator with SOcharader The basic IMelliKnight 5700 system LCD display. can be enhanced by adding modules . RS-485 bus provides communication such as tFre Remote Annunciator, the to system accessories. Serial/Parallel InteAace (for printing . Up or pownload programming, event system reports), and an Intelligent hiffiory, or detec[or status via remote Power Module. The Madel 5700 also or direct connection. features a powerful buitt-in dual line fire , guiR-in RS-232 interface for communicator thai allows for reporting programming via PC. of all system activiry to a remote . guitt-in Form C trouble relay rated at monitoring location. 2,5 amps at 24 VDC. Featu►es • Two buitt-in Fortn C programmable • Up to 50 addressable points. relays rated at 2.5 amps at 24 VDC. • Up to 125 zones and 725 ou[put ppprovals: MOdel 5700 groups. UL Listed / NFPA 72 (File No. 52766) M~hanical Specifications• • Uses standard wire-no shielded or -Central Station Dimensions: twisted pair required. -DACT ~p_g/q~~yy x 15-1/8'H x 3-3/8"D • Buitt-in digital communicator. -Local Protective (32.39 x 38.42 x 8.57 cm) • Central station reporting by Point or Signalling System Wei ht: 11.5 Ibs. (52 kg) -Water Deluge 9 by Zone. • Su Rs Class B(Style 4) and Class Releasing Service Color: Red PP- A(Siyle 6 or 7) configuretion for SLC. • Diffiribu[ed, intelligeni power. • Drift compensation. • 13 pre-programmed output cadences, (including ANSI3.41), and 4 programmable outputs. • Notitication circuits can be configured as 1 Class A(Sryle Z) or 2 Class B (STyIe Y), or auxiliary power for reseitable, constant, or door holder power. CSFM Listed Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A at 24 VDC 2.5 amps at 24 VDC of power-limited notification power Standby Curtent: 160 mA Alartn Current 330 mA NotiflcatloNAux power circuits: 2.5 amps of power-limited power per circuit at 24 VDC. Telephone Requiremenis: FCC Part 15 and Part 68 approved Type of Jack: RJ31 X(two required) SILENT KNIGHT SLC Sensor Devices SD500-MIM SD505-APS Mini Dry Coma version W the Addressable photceleclric smoke deteclor. SD505-AHS Addressable heat sensor. SD505-6AB Six inch base designed for use with detector head models SD50.5-APS,and SD505-AHS. SD505-61B ghort circuit isolator base for SD505-ANS, and SD505-APS deiectors. SD505-ADH Duc[ Housing. Detecls smoke in HVAC tlucts. Use wilh SD505-APS. SD505-ADHRlDTS AtldressaWe Ducl smoke detector with built- in retay module detects produc[s ot canbustion preseM in air rtwving through an HVAC system- Provides Mrtn C alarm contact. 7tie SD505-ADHR is compatible with ihe SD505-DTS, which provides remote annunciation and testing capabilities for the SD505-ADHR. Use with SD505-APS. SD500-PS/PSDA Addressable PuA Stalion with visible LED. Intelligent SLC Modules SD500-AIM pry Contact Input Module. Designed to usetl with normaqy open dry contacts. Mounts in a 4 inch square eiectriql box It teatures an indicator LED to show alarm status and a coverplate. cl Inpul Module. A miniature adOressable input motlule which is designed to be used with pull s[ations afM oTher nortnaly open dry contsct inputs where a smaller size is desiretl. SD500-ARM Addressable Relay Module. Features 2 Fortn C oulput relays, designed to mount on a 4 inch square electrical box. Provides indicator LED to show autput status and comes with a coverPlaffi. SD500-LED An LED driver capabie of driving 80 LEDs mraugh the SlC loop. Up ro 40 S0500- LEDs can be used per system. SD500-LIM Addressable short circu0 isdffior motlule for SLC devices SBUS Accessories The following items listed are devices that connected to the InlelliKnight's RS-485 Bus 5860 Remote Fire Annuncfator The 5860 features ihe same 80 charac[er baddtt LCD display keypad arW firefigMefs keyswitch as ihe 5820. The system can be fulN Pro9rammed and operated from arry remote annunciator. 5880 LED/10 Module Features 40 LED outpu[s, 8 normalty open dry coMact inprts and one piem ouqput. 5496 Intelligent Power Module The 5496 is a 6 amp.notificaHon power espander that provitles tour additional power-limited notificauon applianca arcuR. 5700 5865-3 and 5865-4 Remote LED Annunciffior Feafures 30 ) programmabie LEDS (15 red and 15 Yelbw) outPuts . and piezo SourMer. The 5865d adds a silerice and reset switch to the packa9e 5883 Relay Board Features 10 Generel puryose Fortn C relays. Used with 5880 module. 5824 SeriaUParallel Gateway Module Has one parellel arM one HS-232 serial port tor connecling any standard IBMcompatible priMer to Me IntelliKnight system. IMertaces with building conird system. SKSS Sllent Knight Software Suite 5660 Up Download Soitware User-friBMly, WindowsTM solM1Vare fof remote programming of Me IntelliKnigM panel using a PC. 5670 Facility Management $OtlWB►C Powerlul end-user soflware albws viewing W detector stalus antl eveM history via modem or direct connedion. ~ SILENT.,. KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 900-44646444 or in Minnesota 763-493-6435 FORMIi 350392-Preliminary, Rev. 101IX3 FAX: 763-493-6475 Copyright 0 2003 Silent KnigM World Wide Web: http://www.silentknight.com Mode15860 , Remote Annunciator Bring the power to control IntelliKnighto to every area within your facility. Now you can operate and program your lntelliKnight system from up to 8 locations throughout your facility. The Model 5860 Remote Annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations-including reset, silence, detector status checking, fire drill, and programming-are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. MOdel 5860 Users identiiy themselves to the Remote Annunciator ~ntrol panel by entering a code on the annunciator or by tuming the The 5860 is designed to look and firefighter's key. When a user _ operate exactly the same as the presses a button, the annunciator ' s uu lntelliKnight built-in annunciator. pieZO beeps and the LCD prompts . . ca-~~~ Features indude an 80-charac[er the user to enter a code or other m backlit LCD providing easy-to- relevant information. understand system messages. The annunciator is ergonomically Multiple users can work at different 5860 Remote Annunciator designed wRh over-sized buttons annunciators simultaneously Sp@CIfiC8t1011S for the most frequently used without affecting each other. features, like Reset and Silence. F@8tU1'@S In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. • 80character display • Tactile/audible feedback • Accepts user codes or firefighter's key • RS-485 interface to panel The annunciator is available in gray to match viAually any decor and red for applications where the annunciator must stand out. The annunciator endosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Operation When the system is normal and receiving AC power, the power LED is lit and all other LEDs are off. Other LEDs tum on as the conditions occur. • Can be flush- or surface- mounted. Trim ring available for surface-mounting. • Operation and appearance identical to on-board annunciator • Supports simultaneous use by multiple users • UL listed, complies with NFPA 72 • CSFM Approved • MEA Listed • FM Approved oPemurg vonaye: za voc SNandby Curtent: 20 mA Alartn Currenl 25 mA Max. per system: 6 Ambient Tempera[ure: 32°F to 120°F (0°C to a9°C) Mountirg: Surface or flush Wiring Distance fran lntelliKnight panel: Up [0 6,000 teet Dimensions: Height:7-3/8" Width: 9-118" Depth: 1-1l2" Colors: Lt. gray (5860) Red (5860R) m SILENT KNIGHT . Model 5860 Remote Annunciator Engineering Specifications i The main control must have a built-in annunciator and must support up to eigh[ remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in lwo colors, red or light gray. Remote annunciators shall have identical fundionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All conVols and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a Vavel of .040 inches. No membrane style buttons will be pertnissible. The annunciator must be able to silence and reset alartns through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. 5860 Block Diagram SILENT KNIGNf 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6441 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Up to BOOD feet fiom Panel ► ~ ~"w~ua ~S ~ Up to 8 de.~ees per system. MADE IN AMERICA FORMk 350224, Rev. 01/01 Copyright (D 2001 Silent KnigM SD500-PS and SD500-PSDA , Addressable Pull-Station IntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent KnighYs IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alartn signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious second eeal o'nstructionh at lasts and larm. The SD500-PS/PSDA mounts to a single gang box and teatures a rugged lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. MOdel SD500-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated contacts. Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construdion A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals - accept up to 14 gauge wire • Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull statlon opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 700 feet away. The pull station is reset by retuming the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a staTUS LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDG Standby Curtent: .55mA Alartn Current .55r"A Ambien[ Temperaiure: 32°F to 120°F (o°c io as°c) MounNng: Single gang box - Optional Red Surface Mount Box PS-SM88 SILENT KNIGHT SD500-PS SD500-PS and SD500-PSDA ~ Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 318 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall maich the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and riuo connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings. Manual stations shall be Undervuriters laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FACP _ 7•~.1 _ " . . . ~ ~ _ ♦ ♦ ~ r ~ ♦ . ; ~ ~ ~ . . ♦ . . -y . • . ~s ~ A. . ~ ~ . ,t \ , ` . ~ . . ~ Wiring Mounting to Optional Mounting to Single Surface Mount Box Gang Electrical Box S-0!16' SF1FOp-PSDA ac. i•°,: ' ~ . > srvm~z~ ~ ; , 1 I 3 [~cA sw nw.t e. al ►M t.tiY' dm Installing SD500-1K Dimensions ~ SILENT KNIGHT 1.11 7550 Meridian Circle, Maple Grove, MN 55369-4927 800.446-6444 or in Minnesota 763-493-6435 FAX:763-493-6475 World Wide Web: http://www.silentknight.oom MADE IN AMERICA FORMR 350.342. Rev. 09/03 Copyrigh[ 0 2003 SileM Knight Addressable Photoeledric Type Smoke Detector Deted smoldering fires quickly and get help fast with IntelliKnighto photoeledric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No preciaus seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple-even from a remote site. Like other IntelliKnight detector models, the SD505-APS otFers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing wmplete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors--easy installation, stable operation, RFttransient protection, and vandal-resistant locking--and it adds up to a flexible solution for all your fire protection needs. Nk" SD5054M The light received is canverted into M an eledronic signal. Under normal ~y conditions, the status LED blinks nwft"dc TV" approximately every 15 seconds, S~~ D619dW indicating that the head is communicating with the loop. The The SD505-APS is particularly suited to deteding dense smoke typical of fires involving materials such as soft fumishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. LED lights continuously during the alarm period. 01 F60hIfl6 • Low prafile, 2 inches, including base • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built-in fire test feature • Simple detedor calibration testing through the control panel or remotely through a WindowsT^" based computer soitware. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). OPWON The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is refleded from the smoke particles to the receiving element. • Vandal-resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM approved • MEA approved • FM Approved SM054PS Soolm D6fYdOf $PWRGYHOIIf Operating Voltage: 1741 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Tempereture: 320F to 1001F (o°c to 5(°c) Mounting: 4° Square, 4° OCT, Single gang mud ring Reletive Humidity: BS% noncondensing Air Velocity: 0- 300 FPM Compatible Bases: SD505-6AB (Sold Separately) (6' Base) 505054AB (4" Base) SILENT K1vIGHT . Model SD505-APS Addressable Photoelectric Type Smoke ~ Detector Emonadee *dftw&m The contractor shall fumish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be ULO listed compatible with Siient KnighYs IntelliKnight fire control panels. The base shall pertnit dired interchange with Silent Knight SD505-AIS lonization Smoke Detedor, or SD505- AHS Hea1 Detedor. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is aduated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel resei switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for extemal test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functianal test of the detector. The test method shall simulate efFects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5-15116' C-) C) Height = 2 inches, induding base Model 5D505-M Ddedor 9aw Model SD505-M DoN-or Head ({WVWA KrorV"') SILENT IINIGHT 7550 Meridian Circle, Maple Grove, MN 553694927 8004466444 or in Minnesota 763-493~'i435 FAX: 763493-6475 World Wide Web: http://www.silentknight.wm MADE IN AMERICA FORMfF 350225, Rev. 12/01 Copyright 0 2001 Siient Knight Diameter = 3-15H 6" MEA I~ ADA , Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or Wheelock's patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/1 tOcd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensi5es of 15l30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant volfage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-12/24-8CP and PS-1224-BMP Power Supplies with Patented Sync Protocol, synchronization of the conGnuous horn tone provides the temporat (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattem when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. For Weatherproof Series AS, See Datasheet S9004 SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCI SERIES AH AUDIBLES SERIES AS SERIES AH ®R ~YXI Multi-Candela Indicator (bottom of lens) Features • Approvals inGude: UL Shandard 1971. UL Standard 464 NewYork City (MEA). Califomia Sfate Fire Marshal (CSFM), Fadory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Infortnation. • ADAINFPAIUFCIANSI Compiiant • Wall mount models are available with Field Selectable Candela Settings of 15/30175/110cd or 1351185cd (Multi-Candela models) or 1575cd (single candela model) • Ceiling mount models are available with field selectable pndela settings of 15/30175/95cd or 11511770d (multi-candela ceiling models) • Seledable Continuous Hom or Temporal (Code 3). • 3 Seiedable dBA settings (99, 95 and 90 dBA) in both tones • Patented 2-Wire Audible Strobe ApPliance. • Patented Universal Mounting Plate • Weatherproof models are available for outdoor use • Strobes produce 1 flash per second over the regulated voltage range • 12 and 24 VDC models with wide UL "Regulated Vottage Range" using filtered DC or unfiltered fWR input vottage • The strobes can be synchronized using Wheelodc's sync modules or power supplies with buitt in sync protocol • Fast installation with INIOUT screw tertninals using #12 to #18 AWG wires Copynght 2004 Wheelock Inc. All rights reserved -A 111111 1111~ Helping People Take Actions' NOTE: All CAUTIONS and WARNINGS are Identifled by the symbol AL. All waminga are printed in bold eapital lette's• sPEciFlcA-nONS BEFORE INSTRUCTIONS AND ING, pppLNG TH S PRODUCT. FAL UTHESE RE TO COMiPLY WITH ANY OF THSS ESE NTED STRUTCTIONS, CAUiIONS OR WARMNGS CWLD RESULT~IN MPROPER SPECIFYING OR ppWJCATiON, INSTAL1A710N ANDIOR OPERATbN OF TNFSE PRODMTS IN AN EMERGENCY SfTUA710N, W WCH COULD RESULT IN PROPERTV DAIMGE, AND SERWUS IM.N1RY OR DEATN TO YOU pNDIOR OTHERS. GeneralNotes • Strobes are designed to flash at 1 flash per secorW minimum over the Regulated VoMage Range. Note thal NFPA-72 (1999) specifies a as rate of 1 to 2 flashes per secontl and ADA Guidelines speciy a flash rate of 1 to 3 flashes per secorW. All pndela ralings represent minimum etFeclive Strobe iMensity basetl on UL SlaiMard 1971. • Series AS Slrobe protluds are listed under UL Sandard 1971 for indoor use with a temperature range of 32° F to 120° F(0° C to 49° C) and maxdmum humidily of 93% (t 2%). Series AH-24 homs a2 listed under UL StafWard 464 for audiDle signal appliances (Intloor use only). Series AH-24WP autlible appliances are listed under UL StanCard 464 for Indoorlouldoor use wiM a temperelure ran9e of -31°F to 150°F • (-35°C to 66°C) and maximum humidity of 95%. "Regulated Volfage Range" Is the newest tarminology used by UL to identity the vottage range. Prior to thls changa, UL • used the terminology "Llsted VoNage Range". .ni. z: aea re.unas ro.+z wc aria u voc s.r+.: wsInx +z md u voc auaer iexriptien ~°w^~ P L 464 @ 10 R tlBAg10R High 91 ~ Cortinuus Ham Metlivn 88 95 - low 83 90 High e7 w Code3NOm Metliun 04 95 - ]9 90 Table 3: Aw2ge RMS Cui 24 VDC Models 24 vdt High (89) dBA UL maa' rerM1 Audible AH-24 0.082 0.080 VWII Mount AuAible Strobe Mlotlela AS-141575W AS-MMCW AS-24MCWH 1575cd 15Cd 301d 7510 110cd 135cd 1850d 0.100 0.080 0.102 0.750 0.194 0.250 0.720 0.121 0.086 0.125 0200 0267 0.355 0.480 CeUing Nbunt Strobe AS-24MCC 15rd 30ttl 750d 95cd 0.714 0.165 0.205 0.095 0.138 0221 0285 Models AS-34NICCH 115cd 177cd 0.250 0.3Y0 0.355 0. Med (95) ABA 24vdc ULmac' 0.033 0.043 0.080 0.707 0.060 0.074 0.084 0.110 0.112 0.790 0.771 0253 0210 0.340 0.305 0.465 0%8 0.080 0.092 0.122 0.145 0207 0.186 0269 O.Y30 0.340 O.J05 0. 1 Low (90) dBA 24vtlc UL ma~c" 0.077 0.027 0.072 0.100 0.052 0.068 0.076 0.105 0.121 0.182 0.158 0245 0.220 0.335 0295 0.460 0.056 0.074 0.082 0.113 0.132 0.198 0.177 0263 0.220 0.335 0.295 0. 12 VDC Models Audible ~b Mount AuUible Strobe AH-02 ASd21575W 12 Wc 0.163 0260 High (99) dBA UL max` 0.192 0320 12 Wc 0.076 0.195 Med (95) dBA UL maX' 0.708 0275 12 Wc 0.039 0.175 Low (90) EBA ULmax` 0.058 0265 ' RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current wdhin the listed voltage range (16- 33v for 24v units). For strobes the UL max current is usually at the minimum listed vottage (16v for 24v units). For audibles the max wrtent is usually at the maximum listed voltage (33v for24v units). For unfittered FWR ratings, see installation instructions. d VWARNING: CONmcI p3 SINGLE CANDELA. (p83519) S.I. AH• (Po3641) Sarlea 11H-WV AND" DOCUMENTS COl1fAIN IMPOR~TAENT IN OXMA710N TSiAT SHOULD BE READ PRIOR SPECIFYINC OR NSTALNG 1HESE PRODUC75, INCLUOING~ MIITERIA TOTAI GURRFHT REGURED BY ALL I1PPLll1NCE5 CaNNECTED TO SYSTEM SECONDARY POWER SOURCES. • fUSERATNGSONlpTiFICATONl1PPW1NCEqRCUITSTOFWNDLEPFAKCURREN7SFROYALL APPIJANCESON7HOSEqRCUrtS. PLACING CANDBA CHANGING SEM • D ADDINC, RAW REINSURE TNAT TE IOTILL AVER~ACNCCISIRREMCTA~ IOTAI PEAK REMARE BVOLL Y ALL AEPPWINUCESNDO NOT IXC D 1FIE RATEDRRENT CAPACITY OF THE POWER SWRCE OR FUSES. CqApp31TE FUSN RATE FROM MULTIPLE STROBES YN7MIN A PERSON'S FIELD OF VIEW. • 7HE VOLTAGE APPLIED 70 TMESE PRODUCTg MUST BE YY17MIN THEIR "REGULATED VOLTAGE W1NGE". • Iqg7pLUTON OF 770 CANDELA STR06E PRODUCTS IN SLEEPING AREHS. • INSTALIATION IN OFFICE ANEASAND OTHER SPECIFICAiION AND INSTALlA7iON ISSUES. • TMESE ppp~JpNCEg pRE NOT DESIGNED lO BE USED ON CODED SY3TEMS IN WFMCH THE APPLIED VOLTAGE 15 CYCLED ON AND OFF. WffH IMPROPER COIJLD INFORMA INSTRUC INSTALLA • FnA1LpnON, AMNdOR OPEMTOrN OF THESE PRODUCT5nO1N AM EMERGENCY S~IITONNWMCH COULD RESRUL7 ~NINILT 'N~OPERTY DAMN E AtDTON, SERIOUS INJURY OR DFATH 70 YOU ANDIOR O7HERS. CONWC70R SRE (AWC+). LENGTH AND 11MPAGTY SHOULD BE TAKEN INTO CONSIDERA710N PRIOR lO DE81GN AND INSTALIA710N OF THESE • pRODUCTS, PARTICULARLY IN RETROFIT INSTALLATONS. _'_~_-_-RONIZED DULE SERIES AS APPLIANCES NONSYNCHRONIZED SINGLE CS SS~`B" NAC C RCUHT WI HAUDIBLES LENCE FEATURE FROM PRECEDING * + APPLIANCE OR FACP F SERIES AS APPLIANCES SYNCHRONRED WITH DSM MO WLE CLqSS"A"NACCIRCUITWITHNOAUDIBLESiLENCEFEATURE SERIESASAPPLIANCESSYNCHRONIZEDWITHMULTIPLEDSM MODULES DSM #1 F A C P Interconnecting wtrin9 stwwn. Mazlmum oi twenry (20) SERIES AS 6 RSS APPLIANCES SYNCHRONIZED WITH PS4 2124-BCF and PS-12124-BMP AS SOLB aurr~~s F .aa~ss A OR AS C I P ~ s...~,nb+o ars,rn.wv SM TO NEXT APPLIANCE OR EOLR = s es Audlb~W -~-~-1 NRC c~rcun Syn inst for nformatioln on M powerDs ppl escreferdto I s allational sWct ons P84515 toalPS-12124$CPoand P84333 foSPS1224 BMP. ~r DSM. For wiring Wheelode proUUCts must be used wiMin their published specifiwtlons and must be PROPERLY specifiad, applied, installed, operaled, maiMained and and operatlonaily tested in accordance with iheir installation instructlais at the time of in ~Iba6on ^ ~Ilation,sope tion, maintenance ~and tes[in9 accordance witli local, state arM federal wdes, regula6ons and laws. Specification, app imust be perfofined bY Qualified Pem°^~i fbr proper operation in accoidance with all of the latest Na6onal Fire Protection Assodafion (NFPA), UrMerwriters' Laboratories (UL), National EIecU9cal Cotle (NEC), Ocapational Safery and Heatth Adminishation (OSHA), bcel, state, couMy, province, disirict, federal and other applicable buiiding and fire standards, guidelines, regulations, laws and coCes induding, but not limited to, all appendices and amendmeMs and the requirements of the local authority having juristlicdon (AHJ). Architects and En ineers 5pectticavons The notifcation appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or Indoor approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing n-g). Both Impaired) for shall meet Fire Protection Service. The Series AH Audible shall be UL Listed under Sfandard 464 (Fire Protec[ive Signali the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of dreuit winng by a Fire Alartn Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field seledable settings for dBA Ieveis and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube endosed in a rugged Lexan@ Iens. The Series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have fietd selectable settings and shall be rated per UL Sfandard 1971 at 15I30/75/110 or 135I185 candela for wall mount and 15/30f75195 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistani. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelodc's pS-12/24-8CP or PS-12/24-8MP Power Supplies with built-in Patented Sync Protocol. The s~ntacts rema n closed)f synchronization at any time during operation. If the sync module or Power Supply Tails to operate, (I ~.e the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe adivation when used with Wheelodc synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporete a Patented Universal Mounting Plate that shall allow mounting to a singleyang, doubleyang, 4-inch square, 100mm European type badcboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering /nformation ' I syncw~sh4osr I MoCN I ~ I Stro4e Candals NonSync P L I PS1L14lMP 1 AS-24MCW-FR 9020 ~ 15(JMS/110 I % K AS24MCW-FW 9025 i. 153095I110 X .K . A521MGWM-PR ~ _ 3L56 I ~ 1351185 I X I X ASd410CNMFW 3de9 I, 135I185 % I x AS-241RSW-FR I 7405 ~ 15(/SOnAnsl l X. j % A5121575W-FR ` . .7410 15(75onAZS)I t X.. A521MCGFR I 3161 15ld0//595 % I X MS-]IMCGF'M _ 4 3182 I 15flDIl595 X I X... AS-24MCC1LFW ~ 3469 y I 115I177 X I X ASWP]QSWFR^ 9012 I 75~31 F ~ X I X. AH-24R 7892 I - I 1 x ~ i X.. r AK24 W~ 1B93 _ ~ % X AH-02R AH-12-W ~ 7894 ~ - - • ~ . x AK24VrP.R" 1116 - . x I . X . A&12WP-R" . . ~ 7I15 I X I X i Ag.Mr 12 w.. c,w„9 t. 'I mrt ' Momrt ~.~9 ~ftnsN UL MEA LSFM iM T BFP l ypC I ypc ~,y ~-III A,B.D,EFGHJ,N,O.R,%_L %r%- , X + I%-t X I x. .I il AB.~.EFGHJ,N,O,R,X ~ X~ X~. % I KL xJ X_ I X II A,B.D,EFGHJ,N,O.RX X I X i_% I X I* I X I II X IA.B,D,E,FGMJNO,R,X I X X~ X f X X II. X I X ll ~ A.B,qEFGHJNO,R%~ X~ %-t X I X C%1 g X I A.B,D.EFGHJN,O,R,% ~X II % % I X X % ~ AB,D,EFGHJ,N,ORX I Xi X~ X~ X~~. I XI t I% I ABpEFGHJNOR,X CXa X~I. %~X~ ~.i X I% XI ~II r x X I I A(wee ,B,OEPGHJeN,O,R.% X I % X Xt I x 1 I I AB,OEFGHJNOR% X I X j X 1 X I-x I I X~ x I X I ABpEFGHJNORXj%~%~ X~X I X_I X X x K ~X X] I X~ I X. I % I X I % K ~ % . % X I _ _ . *PENDING Note: Models are availaDle in either Red or Nfiile. Contact Customer Service for Order Code antl Delivery. ••FOr Weatherproof Series ASIAH specifications see Aata sheet 59004. "`Refer to Data Sheet 57000 Por Moun6ng Oplions. NOTE: Due to continuous development of our products, specificadons aod offetings are subject W change without notice in accordance wifh Wheelock Inc. standard terins and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3YEARWARRANTY Made in USA Distributed By: NATIONAL SALES OFFICE 1-800-631-2148 ~ Canada 800 397-5777 E-mail: I nfo(awheelockinc.com http://www.wheelockinc.com wNEELOCK INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 SB'OO07104 heeJo O MEA - ,non ~ DESCR/PTION Wheelock's paYented Series RSS StrobeAppliances and Series RSSP Strobe Plates have lowercurrent drawwhile maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wail or ceiling mount applications. Strobe options for wall mount models include 1575 or Wheelock's Patented MCW muRi-candela strobe with field selectable candela settings of 15/308 5/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi- candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-12124-8CP and PS12/248MP Power Supplies with Wheelock's Paterded Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations conceming photosensitive epilepsy as well as meeting the requirements of NFPA72. Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, t 00mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional.65" oftrim fwtheAppliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4° backboxes or for surface mount use with Wheelock's S131-2 surface backbox. SERIES RSS & RSSP SINGLE & MULTI-CANDELA STROBES & STROBE PLATES r J ~ `~.....r Series RSS RSS Round Series RSSP ~ - ;~SiYM o~t Multi-Candela Indicator (bottom of Strobe Lens) Features • Approvalsinclude: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Infortnation • ADAlNFPA/UFC/ANSI compliant. Meets OSHA29 Part 7910.165 • Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15130/ 751110cd or 1351785cd. Single Candela models are available in 1575cd • Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cdor175N77cd. (RoundorSquare) • Strobes produce t flash per second over the regulated voltage range • 12 and 24 VDC models with wide UL "Regulated Voltage" using filtered (DC) or unfiltered VRMS input voRage • Synchronize using Wheelock's sync modules or power supplies with built-in sync protocol - Fast installation with IN/OUT screw tertninals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 Copyright 2004 Wheelock, Inc. All Nghts reserved• Helping People Take Actionsr' NOTE: AII CAUTIONS and WARNINGS am identifietl by the symbol A. All waminga are printed in bold wpilal lelters. A WARNING: PLEASEREADTHESESPEqFICAilON3ANDASSOCIA7EDINSTALLAiIONINSTRUC710NSCAREFULLYBEFOREUSING SPECIFYING OR APPlY1NG TlUS PROWCL FAILURE TO COMPLY W17H ANV OF THESE INSTRUCTIONS, CAUTIONS OR WARlANGS COULD RESULT IN IMPROPERAPPLJCATION, INSTALLATON AND/0R OPERA7%Ni OF THESE PROWCISIN AN EMERGENCV SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SEPoOUS INJURY OR DFATH 70YW ANDIOR OTHER5. General Notes • Strobes are designed to flash at 7 flash per second minimum over the Regulated Voltage Range. Note ihat NFPA-72 specifies a flash rate of 1 to 2 flashes per seconA antl ADA Guitlelims speafy a flash rate of 1 l0 3 flashes per semnd. • All candela ratings represent minimum eRective Sirobe iMensiry based on UL Slandartl 1977. • Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperatwe range of 32° F to 120° F(0° C to 49° C) and mabmum humidiry of 93% (t 2%). • °Regulated VoMage Range" B Me nerrest tenninology used by UL to identlfy the voMaga range. Prior W Mls change, UL used Me te,minology °Lbtetl Vollage Range". Table 7: Average RMS CurrenY RSSIRSSP RSSIRSSP - Wall Mount R55 - Ceifing Mount 24VDC 247575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd 30cd 75rd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.795 0.270 0.045 0.070 0.179 0.159 0.195 0.270 Ul maY' 0.090 0.060 0.092 0.165 0220 0.300 0.420 0.065 0.105 0.189 0249 0.300 0.420 RSSIRSSP 24VDC RSSIRSSP VifaII Mount • RMS current retings are per UL average RMS method. UL max curtent ryGng is the maximum RMS current within Me listed voltage range (16-33v Models 121575W for 24v units). For strobes the UL max curtent is usually at the minimum 12 vdc 0.152 listed vottage (16v for 24v units). For audibles the max current is usually at themaximumlistedvoRage(33vfor24vunits). For unfiltered FWR ratings UL max' 0255 , see installation instructions. Table 2: Audibles/Speakew for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Homs AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-101011080, E70, ET70 Chimes CH70 O WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTA WTION INSTRUCTONS^ AND °GENERAL INFORMA710N" SHEET IP82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PEWODIC CNANGES.ITIS IMPORTAN7iHA7YW HAVE CURRENTINFORMA710N ON 7HESE PRODUCTS. THESE IMiERIALS CONTAIN IMPORTANTINFORMATON THATSHW LD BE REI1D PFtIOR TO SPECIFYING OR INSTAWN(i THESE PROWCTS, INCLUqNG: • TOTALWRRENTREWIREDBYALLAPPLWNCESCONNECTEDTOSYS7EMSECONDARYPOMIERSOURCES. • FUSE RATNGS ON NOTFlCATION APPLIANCE qRCUfIS TO HANDLE PENK CURREN73 FROM ALL APPLIANCES 0N THOSE CIRCU175. • ADOING,REPLACINGORCW11k'a1NGAPPLIANCESORCHANGINGCANOELASEffINGBWILL AFFECT CURRENT DRAW. RECALCUTATECURRENT DRAW 70INSURE THAT THE TOTAL AVERAGE CURRENTAtm TOTAL PEAK REWIRED BYALL APPILINCES DO NOT EXCEED iNE RATEO CAPAGTY OF iHE POYYERSWRCE OR FUSES. • COMPOSITE FLASH RI1TE PROM MULTIPLE S7RO8ES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPIIED TO TNESE PRODUCTS MUST BE WIiHIN THEIR "REGUUITED VOLTAGE RANGE". • INSTALLATON OF 710 CANOELA 57ROBE PRODlIC75 IN SLEE%NG AREAS. • INSTALLATIONINOFFICEAREASANDOTHERSPECIFICATONANDINSTAWiIONISSUES. • USE SiROBE3 ONLY ON CIRCUI73 NIITN CONTNUOUSLYAPPLIED OPERA7ING VOLTAGE. DO NOT USE S7ftOBE3 ON CODED OR IN7ERRUPTED CIRCUfTS IN WHICH THE APPUED VOLTqGE IS CVCLED ON AND OFF AS THE STROBES MAY NOT FLASH. • FAILURE i0 COMPLY WITH THE INSTAW1710M INSTRUCl10NS OR GENERAL INFORMNTION SHEETS COULD RESULT IN IMPROPER INSTAL1A710N, APPLICATION, AND/OR OPERATON OF THESE PROWC7S IN AN EMERGENCY SITUATON, NMICH COULD RESULT IN PROPERTY DAIMGE AND SERIOUS INJIIRY OR DEATH TO YW ANQIOR OTHERS. • CONDUCTOR SIZE (AWG), LENG7H ANDAMPACITY SHOULD BE TAKEN INTO CONSIDERA710N PRIOR TO DESIGN AND INSTALLATION OF 7HESE PRODUC75, PARIICULARLV IN REiROF1T INSTALLATONS. 14riring Diagrams " SERIES RSSIRSSP APPLIANCE FROM + + TO NEXT pRECeoir+c _ APPLIANCE pPPL1ANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP + - SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WfTH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE t 0 NAC SYNC e CIRCUIT OUT T ~ ~ IH I RB$ fl55 RS6 ~ MIN1151 FACP e~pVOIBLE Mixus s ~ ♦IN3 RS9 R55 R55 TROBE . oui x NAG CIRCUIT RETURN SERIES RSSIRSSP APPLIANCE SYNCHRONIZED 1MTH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F . srROaE STR08E A s°°°` ~A~ R53 RSS CirtuH C qutibk P EOLR ~uE1Dle SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH MUL7IPLE DSM MODULES DSMl7 Sync SUVCe NPC Cic 0 i RSS RSS F 0- DSM #2 A 54o0e NRC Cir Smt RSS RSS C 8 osM aa P R55 R55 saoe. Nnc c+r . SY DSM Interwnnecting wiring shown. Maximum of Iwenry (20) & VISIBLEAPPLIANCE OPER4TE IN UNISON TO NEXT FROM + APPLIANCE PRECEDING ± OR EOLR APPLIANCE, SYNC MOWLE, POWER SUPPLV OR FACP + _ e + - smoeE nurneU~ STROBEIPLAiE ASSEMBLY AUDIBLE & VISIBLEAPPLIANCE OPERATE INDEPENDENTI.Y GROM .F ~ TONEM VPECE.WG qpPll/JlLE AFPIIMIGEOR_ OREOIR ncv F0.0M T r T TOXE%L PSRECEOINO ~ SIROLEON 1PC9E.SVHC -T"r , r EOLfl MOOIILE. VONEN 6UVPLYORFhCP 57ROBE APPLIANCE ° For detail using SM or DSM Sync Module refer to Data Sheet 53000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring infortnation on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12124-8MP. YVheelock protlucis must be used within tlieir publishetl spedficalions and musl be PROPERLY speafied, applied, installetl, operated, mainfained and operationaily tested in accordance with their insfallation insWcGons at tlie tlme o( insNallation and at least twice a year or more oRen arW in accadance wilh bcal, slate and fede2l codes, reguladons and laws. Speciflcation, apDlication, installation, operation, maintenance and tesling must be pertonned by qualifietl personnel for proper operation in accorclance with all of the latest Nalional Fire Protection Assodation (NFPA), Underwriters Laboratories (UL), National Eleclrical Cotle (NEC), Occupational Safety anA Health AdminisVation (OSHA), loral, state, county, province, district, tederal and other applicable buiWing and fire stafMards, guidelines, regulations, laws and codes inGutling, but noi limited to, all appentlices arW amendments and the requiremenis of the local authority having jurisdiclion (AHJ). SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WRH PS-12/24-8CP or PS-72124-8MP f P 1 MP wa nse Ean ounirs F A rn ~s C : •°.ss P ~ xw senc rsvzauv Architects and The visual notification appliances shall be Wheelodc Series RSS Shobe Appliances or approvetl equals. The Series RSS shall meet and be listed for UL Stantlard 1971 (Emergency Devices for the Hearing-Impairetl) for Indoor Fire Proteclion Service. The strobe shall De listetl for indoor use and shail meet the requirements of FCC Part 15 Class B. The strobe appiiances shall produce a flash rate of one (t) flash per secontl over the Regulated Voltage Range and shall inwrpora}e a Xenon flashtube enGosed in a rugged Lexar@ lens. All inpuk shall be compalible with standard reverse polarity supervision of circuit wiring by a Fire Alami Conhol Panel (FACP). VMen Strobe Plates are to be installeC, they shall be the VMeelock Series RSSP SYrobe Pla[e and shall have ihe same eleclronic dreuiVy as the Wheelotlc Series RSS. The Series RSS Strobe shall be of low current design. Where MuXi-Candela appliances are specifieC, the sUObe intensity shall have fieltl selectable settings and shall be rated per UL Standard 1971 at i 5130/75/110cd or 135I185cd for wall mount and 15130175/950d or 115/177ctl for ceiiing mouM. The selector switU for selecting the can0ela shall be tamper 2sistant. The 1575 cantlela strobe shall be spedfied when 15 candela UL Slandartl 1971 Listing wdh 75 candela on axis is required (e.g. ADA compliance). When synchronizalion is required, the appliance shall be compadble with Wheelock's SM, DSM Sync Motlules or Wheelock's PS-12I248CP and PS-121248MP Power Supplies wkh built-in PateMetl Sync Protocol. The sMObes shall not drift out of synchronization at any dme during operation. If ihe sync module or Power Supply fails to operate, (i.e., conlac[s remain Gosed), the shobe shall reveA to a non-synchronized flash rate. The strobes shall be designed tor indoor suAace of flush mounting. The Series RSS Strobe Appliances shall incorporele a Palenled, Inte9ral Strobe Mounting Plate that shail allow mounling to single-gaixj, double-gang, 4-inch square, 100mm European type badcboxes, or ihe SHBB Surface Badcbox. If requiretl, an NATP (Notfica6on Appliance Trimplate) shall be provideA. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installalion is completed. The Series RSSP MNti-Cantlela or single candela Strobe Plate shall mount to eNher a sfandard 4 inch square backbox kr flush mounting, or ihe Wheelock SBL2 backbox for surtace mouMiig. All notifica[ion appliances shall be backward compatible. Nore~ ow mcol ae.reronam m aoaixw. spKdn~s and oirennes ere woxa ro dal ~m nonce m~ce »;m wnai iM smnmm "s m,a =ama,s. Specirications and Ordering Information ~ smewisr,oax i SveW H I IN M t] i ~ C YMV o4N i M ptlmOO C WN ~ Ye 1 en G nO O YouMlByM C n W er 13G4~CPMP Cebr i. VDC wC RE D Cob I MouMYrO~+ MMRE ~ n ~~a 1 11L FM BFP csFr ~ RSS-YtMCWFR LBMO I % X L X 1SAO/ISH10 I X - % 1 `BOEFGH,JNORX Sp ~ ~ X X ~ % p5g3~MCyJ.iW I 8101 + X I X X 15(lNIS/110 ~ X I- I4 II X I B o E F GH.J N O R X Spulre X X {I X X ~ I RSS3N595WFR 7491~ I X I % % { 15p5aMy - X I % - I F HJNOR% 5 um X - j BDE G . . 9 X X I X X - I RSS'tt15]SWiW RS51115]SW-FR RSS121ASW-FW T/80 ]4]8 ~iKB K X{I X % (]SmAns) - X X t5~/SOn0.vs) l ana) X I X 1SpS Ni I X i X % X . X IBOEFCaH,JNOR% &41°~° % _ . { - {BOEFQH,JNRX~ Spum X BOEFGH,JNORX Syum X I % % % X X % X ~ X±~ % X rX%_ Sggl 9up x I 1Y.WIS95 X I- I t r I % I 4oEFGH,J,MORX SpX I X_ X X I • ` R55-21MCCRFW 3159 ~ X I X % 15I30l1595 % t- l I X IBDEFGM,JNOR% Rwq IX X~. ~ % X _ ~ R55-361lCCHFW NB1 X X~ X HSHT/ i X - X BDEFGH,JNOR% SQUart I X II % ` i ~ I R5634MLCHRFW 3~83 fl5l1Tl ~X X X X - % BOEFGH,JNORX RoviO X X I X ~ MLW}FFR R5321 ~ 4185 1 X I % X 135H85 1 I % X T X ~ B~EFGH,JNORX Sa ~R I X I X RSSMP-21TSWFR" ! Po 3 [ X 180 F I % X ~I X X I X ~ - B,O,EF,GH.J,NOR,XI SQ ~Y2 ' % X ~ X - F 15aJ1 F . I . . I { ~ _ RSSVJP- ~ 3IXN _ % ' F X X ] -T F I ~ % I SVUrt % X BOEF.GN,JNORX ~ ~ ~ X % K I I ~ RSSP-1315'/5W-FR ~ ]998 X I 15 5 o Ausj X t % X % SCUart % E,Z q X 1 X % % 24MGW-FR RSSP 0402 + I% ~ % X 15A0/i5H10 - X % . DEj Spua X I X I % X % ~ - RSSP-3415]SNFFR T183 I x ~ x x 1s ps on AMq ~ r I- I x o Ez I squm I x ~ ~ x I I x x` x I I 135/'IBS X I J N O R% I SQUrt I X I B D E F GH I X X X % ~ RSSPQOMCNR~FR BI82 X X I , L I_ I !1 Models are available in either Red or White. Call Customer Service for Order Code & Delivery. 'PENDING "For Weatherproof Series RSS SUObe speafiptions see data sheet 59004. ""Refer to data sheet 57000 for mounting options. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY Made in USA NATIONAL SALES OFFICE Distributed By: 1-800-631-2148 Canada 800 397-5777 E-mai I: I nfo@wheelockinc.com http"//wwwwheelockinc.com WHEELOCK, INC. • 273 BRANCHPORTAVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S0410 07l04 POl(/ER SON/~ Rechargeable Sealed Lead-Acid Battery PS42" 12 Volt 7.0 Amp. Hrs. Features: • Absorbent Glass Mat (AGM) technology for superior performance. • Valve regulated, spill proof construction allows safe operation in any position. • Power/volume ratio yielding unrivaled energy density. • Rugged plastic case and cover • Approved fortransport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. • U.L. recognized under file number MH 20845. .7Y S PERFORNANCE SPECIFICATONS Nominal VoHage Nominal Capecky 20 hour rate (350mA to 10.50 vol5) 10 hour mte (850mA b 10.50 vd[s) 5 hour raLe (12A to 1020 vdfs) 1 hour rate (4.SA to 9.00 voHS) 15 min rafe (14A to 9.00 vdts) Approxlmate Walyht Ener9Y DensltY (20 hour rate) SpaeHic Enargy (20 hour rate) imemal Rash.mnce (Fmy chareed BatterY) Maximum Diuharye Curre1rt 7 Mln.) Maximum ShorbDUratlon Dfseharge Cu'reM 10 Temdnal eonfl9uratlons Shelf Life of nominal caPacKY ffi 88° F(20° C) 1 Month 3 Monihs 6 MoMhs Opereting Temperature Ranpe 72 voMS (6 celis in series) 97% 91% 83% d-F (-200C) to 122°F (50°C) -4^F (-zo°c) ro 140°F (so°c) A85 Plastic TECHNICAL DATA: SheljLife and Storage too ~ 0 ~ e° O .R. 60 K ~ 40 n a cne~ ~ um, sm „ s (47 c 'F) °B` m ~ remve hN `mer W qp*TC (104°F) 90°C l~°Fl 20°C (ea°F) ~ OOM em~~ eq6 g r ry ri V ~0 2 4 8 B 70 12 74 76 78 ZO Standinp Period (MoMhs) X 100 u gp m w so V 0 40 m 20 m ~ 0 Lije Characteristics in Stand-By (Ise (ee'F) ~ Float Charging Volfage ~ 2.25 - 2.30 VlCell 0 ~ y Years 3 4 Life CharacterisNcs in Cyclic Use n„ao~ oeqntoetc nnc,.,w DeDelfO% Dwmm 1. DlscherW Cumnt 0.3C (Flnal Valbge 1.N/CNq 2. Chuge Cunetk: 0.1C 3. AmbleM Tempantun: 20°C to 25°C (61rF a n'Fl 1 I I I I I 100 ~ U c o 40 c K 20 00 200 400 B00 8W 1000 7Z00 Number oi f.yeles CHARGING ~rcle Applications: Limit initial current to 2.1A. Charge until battery vona9e (urwer cnar9e) reacnes 14.40 ro 14.70 vd4s at sa°F (20°c~. Hold at 14.40 to 14.70 vdts undl arrentdrops to approzimately 70mA. Battery is fully charged under riiese conditions, and charger should either be disconnected or switched to °fioaC voltaga. "FIoaP"or "SWnd-By" Service: Hold baltery across constant vdt- age source of 13.50 to 13.80 voits condnuousty. When held at this voRage, the battery will seek iLS own current Ievei and maintain itself in a fully charged condition. NOTE: Due to the self-discharge charederistics d this type of bat- fery , it is imperative that they be charged after 69 months of stor- age, ottierv+ise permanent loss of capacity migM occur as a resutt ot suifation. M 14,0 13.0 Discharge Characteristics PS-1270 011.0 ~ C 70.0 p. p 0.35A 3. 0 8.0 Flnel 7A von,a. 8.0 8 12 N lbIlt 3 • 6 810 ZO 10 11 3A mM.-~-MS. Dixharge Time 5 G 2 E r I p ~ q E 3( u • O 11 ~ Discharge Time vs. D'ucharge Cunent 20 15 10 Finel Votlp 70.SV e 102 V 9.60 v ~ ~ 9.O ~ V ~ e.+o 40°f m°c o°l v--I 0.35 0.7 7A 3.5 7 74 Dlacharpe Cunent(A) 132*F1 Physical Dimensions: in. (mm) TerrTu^ak T 'F1' v~ ~ 49 ~ W. FTSTIXI ~ (D j oam,owr 595(I51}--=~ M~M PS13]O F~ Y Talersncas an sl-0.W In.ltl-1mm1 anE+b/-Y.OB in.M10BM1t Eimensians. AUAN~sub~e~.~ tlwW CUSTOMER SERVICE SALES & MARKETING e IS~~1-ZOOO 9163 Siempre Yrva Road 3108 Spdng Street p[yf39170 San Diego, CA 92754 USA Redwood City, CA 94083 USA Tel: 679a61-2030 Fax: 619-667.7818 Te1:650-364 5007 Fax:8SOJ66-3662 __.__..._-swww•puwersonlc.com customeraerNce~Peweraonlacom ~ r . ~ ~ E - - ,~.~~,~.~..~,~..,...~d.... .._.~~~,~.~m._.~......,,~..~ ~ YSTEM RE t~IRE1I~ENTS ~ Creek Famil Pract~ce ANALY~YS FOR FIRE ALA~RM 5 ~lear CO~DE Y ~ st 3$th Avenue Su~te ~ffil1S m2m2 d 200~ IFC 907~2.2 7b 1 S We , 2003 IBC - 901 an . lled ir~ Grc~u B accu ancies Wheat R~d e~0 80033 1 fire alarm s stem s~ial~ be ~nsta % ~ Grou B. A manua p P ~ p Y ~ ~ ' m re than 1(~4 er s~r~s a.bave ~n an accu ant load ~f Saa or more ~rso~s or o hav ~ P ~ ~ ~ ~ ~ ~~oo~ ~~c ~ Code x~t d~schar e. w the lowest level of e or be~o , ~ ~ Grc~~ B r sect~an 304,1 ~ Occu anc Class~ficat~on. Bus~ess p, pe P y + I T Of C4riSt~uCt~anm ~ _ h h 8. instail+~d ~n a~cordance w~th cha ters 4 t ou Yl~ NFP~. 72 s s~em sha11 l~ p ~ ~ Y w~,ble Arr+~c~`~-Iei ht ~ Allo ~ W I ~ . . ~ . r~oa 5 ~ ; ~ } ~ s stem is nat re u~°~ howev~r there is an Based on this anal s~s a fire alarm , y ~ Y q Max ~Iei ht; 3 s~a cture. Caver es shall be m+a~ified and g extst~n fire alarm s stem ~n the stru Y ~ g ~ Aet. Area: 3 332 s.ft. ~ q t c~rrr~nt re uiretnents far fire ~larm s stems ~ e u~ ment sha11 be u aded to mee r ~ P~' ~ . 9 PP ~ ~ Act. He~ ht. l sto g w~ lun Cl of Wheat R~d e. mstalled t ~Y g • _.~..,.~..~....a. y~,~.~~..._. ~ ~ I co e ro ec ~ ~~~~;m~ p ~ v ~ . t~~s=~~. ~r~~~ ~ ~ e T,,. I I a.~, r. ►.o ~~.M► ~ I n 1 r~ ~ r, n nl,r~l w c~ c c n In ( o v~ o r'~ ~[1 V'~ 1'Y1 C1 ft 1~'1 A P I''1 C~" P P~C I 4 i Yl Cl i _ _ ~~~;~~i~~ ~ ~ , ~ 0 ~ o ~ ~ ! '*m `°9 ~ 6 ~ ~ , a ' ~j ~ a~ ~ t,~, ~ . , ~~,~.s _ ~ ~ ~ ~ _ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ . ~ . ~ ~ ~ ; . ► - r ~ ! _ k' - ~ ~ ~ . . " ~tic~~r I~~~~i~ L . _ ~ i. _ J ~ ~ ~ ~ _ I i 1 ~ k ■ ~ ~ ~ ~ ~ ~ - ~ 1 ~ ~ ~ ~ ~ ~ ~ ~ . ~ ~ ~ a' ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ _ _ ~ ~ t~ ~ ~ ~ ~ ~ ~ ' L ~ ~ ~ ~ - f ~ ~ ~ , 4-.x~' . ~ ~ ~ . . I~~ ~ I r~ ~ ~ Smoke Detector out ~f Ser~~fiv° X X x ~ r r Smake Deb~or Qi X X X X X Low Ba#e 11oit~a ~ X Na~e: 8 ho~ s~1a to r a~ iass of AC D~cannec~od Power Source x X X y e~rt a~ - - - _ - - = ~ : = Time~° Test 24 haur x 1 ~ r r - ~ ~ ~ i ~ i I ~ a.. ~ ~ i~ 3 ~ i~ ~ V~G~cC'(1 U ~ i ~ ~ s , ~ ~ f i ~ ~ T~ s . ~ ~ , ~ ~ i ~ ~ d ~ ~ I 'e ~ ' . s n - ~ • r.~~ ~ ~.i ~ ~ ~MIO!'It ~1t~ ' , ; - , ~ a o 0 y~ loll ~ V~SIYI ~ ~r ! ~ 1 a , o ~ :p-'~~- I~Q ~~~1~ co oc ~~1Un o e ecuri en ra ~ f ~ ven~e ree e ~ f B i 'r~^~, m ~ ~i I I~~ ~ ~ 0 coUn c ~ ~ ~ ~ ~ ~ ~ ~ '~~n irs . i i ~ . ~ . f ~ ! , , ~ . , F- ~ I COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 17574 BUILDING INSPECTION LINE -(305-2345933) Date : 8/17/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: W ESTERN CENTERS INC. Property Address : 7615 W 38TH AVE Phone : 306-1000X16 Contractor License No. : 22070 Company : Jacobs Const. Co. Phone : 766-0147 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby ceRify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of lhe City of Wheat Ridge or covenants, easements or restrictions of rewrd; that all measurements shown, and allegations made are accurete; that I have read and agree to abide by all condiGons printed on this application, and lhat I assume full responsibility for compliance with the Wheat Ridge Buildin9 Code (U.B.C.) and all other applicable Wheal Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE Description : SOFFIT REPAIR Construction Value : $3,500.00 Permit Fee : $126.50 Plan Review Fee : $0.00 Use Tax : $42.00 Total: $168.50 Use: &Za BUILDING DEPARTMENT USE ONLY tonlrn9 ftnI&IN SIC : Sq. Ft. : Approval : Zoning : 9~l~tdwg C&~~ Approval: Puslist*64 GrMOW Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company : Expiration Date : Approval : Mechanical License No : Company : Expiration Date : Approval : (1) This permit was issued in accoldance with ihe provisions set forth in yopur application antl is subject lo the laws of the State of Colorado and lo the Zoning Regulations and Building Code of W heat Ridge, Coloratlo or any other applicable ordinancas of the City. (2) This permit shall expire if (A) the vrork authorized is not commenced within sinly (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of'120 days. (3) If this permit expires, a new pertnit may be acquired for a fee of one-half the amount nortnally required, provided no changes have been or will be made in the onginal plans and specifcations and any suspension or abandonment has not excee0ed one (1) year. If changes are made or i( suspension or abantlonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural Oow of water causing a drainage problem. (5) Contractor shall notify the 8uilding Inspeclor N+enry-four (24) hours in advance for all inspections and shall receive writlen approval on inspection card bafore proceediing vrith successive phases of the job. (6) The issuance of a pertnit or the approval of drawings and specifcations shall not be construed to be a permit for, nor an approval of, any violation of ihe provisions of the building codes or any other ordinance, law, rule or regulation. Chief Building Inspector Please sign Terms and Conditions on reverse side of page. w~E, COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: o~ BUILDING INSPECTION LINE - 303•234-5933 Date: ~ $ C1TY OF WHEAT RIDGE " 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) ~°`°a"°° APPLICATION Property Owner: ~«~t.•~ r~le~f 1 c, PropertyAddress: Phone:3~3-3d6'/OGY7X/6 Contractor License No.: ;U070 Company: Jq,,,6s ~'o„s}, ~ Phone:.703 -76d -O/V 7 OWNER/CONTRACTOR SIGNA7URE OF UNUERSTANDING AND AGREEMENT I hereby ceAily that the setback distances proposed by ihis permit applicaUOn are accurate, and do not violate apOliwDle ordinances, rules or regulatlons of the City of W heat Ridpe or covenants, easements or restricfions of recor0: that atl measurements shown, and allepa6ons made are accurate; thai I have read and agree to abiCe by a11 wndiUons printed on this aDDlication and that I assume full responsibility for compliance with the Wheat Ridge Buil0in9 Cotle (U.B.C) and all other applicable Wheat Ridge Ordinances, for work under Nis permit. ~ (OwNERxCONTRACTOR):PRINTED Description: ee'oo5%', Sq. Ft. adMd COIISINCIl011 V31UC:$ Permit Fee:$ Plan Review Fee:$ I Tse Tax -R Total:$ Expiration Date: Expiration Date: Expiration Date: ApProval: ApProval: ApProval: (1) TAis pertnil was issued in acwrdance wiM the provisrons set iwth in your appliption arM is subject W tlro laws of the SUIe o( Cobrado arb W the Zonirq Regulations and Building CoOes of W heat Ridpe. Cdorado w any other appiiwble ordinances of tlte City. (2) This permil shall expire if (A) the work auttwrized is not commenced within sirzly (60) days from issue date or (8) the building autlwr¢ed is wspentle0 or abandone0 fa a period oi 120 days. (3) If ihb permit axpires, a naw pertnit may be acquirotl for a fea of ono-hal( the amounl nortnally requireE, providetl no chanpes have been otwill be meAe in the wgiW Plans and sDedfications and any wapensiai or abandonment Aas not exceedeE one (1) year. Ii changes have been a if suspension a abandonment exceeds one (1) year, lull fees shall be paid fw a new permR (4) No work oT any manner shall be done Ihat will chanpe the naWral flow oi "ler wusing a dminape proDlem. (5) Contraclor shall rqtify tlx Buildinp Inspectw lwenty-four (24) hours in advance fw all inspecGons an0 shall receive wrinen approwl on inspection prd Detore proceedinp wiM successive phases of the joD. (6) 1Ta issuance of a pertnit or Gv approvai o( drawings arW spetlfications shall not be conatrued W be a pertnit iw, nw an approval of, any violalion ot the Orovisions of the Ouilding codes or any other ordinance, law, rule or ragulation. Chief Building Official Elecfical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Jeff Jacobs Telephone (303)766-0147 5624 S. Andes St. Aurora, Co. 80075 Stope ol L,/or/ll ~ . ~20 L F" mo te / ~lmvvc /,g /~ox ~J ) &,,IACf /~~~oX . d 0 Z6" -5'o"i/ ~ 't Rinooe 9/4p/tce ls~/e/:on i,,i s ~Pla~~ ~aMafec/ Gs,/, ~qJo,rfs ~ Sc010G o/ 6)ork > ~Hf open i-n P~:,61e.h . ) f COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : BUILDING INSPECTION LINE -(SOS-234-5933) Date : CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) 17515 8/5/2004 Property Owner: W ESTERN CENTERS INC. Property Address : 7615 W 38TH AVE #B-115 Phone : 306- 1000X18 Contractor License No. : 22070 Company : Jacobs Const. Co. Phone : 766-0147 OWNER/CONTRACTOR SIGNATURE OF UNDERS7ANDING AND AGREEMENT Construction Value : $42,500.00 I hereby certify that the setback distances proposed by this pertnit application are accurate, and Permit Fee : $745.04 do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or tions of record; that all measurements shown, and allegations t i t Plan Review Fee : $484.28 r c s or res covenants, easemen made are accurate; that I have read and agree to abide by all conditlons pnnted on this US@ T8x : $510.00 application, and that I assume full responsibility for compliance with the W heat Ridge Building Code (U.B.C.) and all other applicable W heat Ridge or nances, for work under this permit. Y/~f~~~/ Total: $1.739.32 ~ DATE (OWNER)(CONTRACTOR) SIGNED Use : /,8b'f.3z Description : TENANT FINISH ~ Cajo~nts:' Approval : JH Zoning : pCD Approval: CR p~~IcwAlrW-S,30ytp1►er s: Approval : Occupancy: B Walls Electrical License No : 21517 Company : LANCE ELECTRIC Expiration Date : 2/28I2005 Approval : OKIKS BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : 8113104. OK FOR MEDICAL OFFICE AS TENANT OK WI COMMENTS Roof : Stories Plumbing License No :22040 Company :Schuckman's Plumbing & Heating Expiration Date : 7/22/2005 Approval: oklks Residential Units : Mechanical License No Company : Expiration Date : Approval : (1) This pertnit was issued in accortlance with the provisions set forth in yopur applicalion antl is suDject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge. Coloredo or any other applicable orUinances of the CiTy. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building aufhorized is suspended or abandoned for a period of 120 days. (3) If this pertnit ezpiras, a new permit may be acquiretl for a fee of one-half the amount nortnally required, provided no changes have been orwill be made in the original plans and specifcations and any suspension or abandonment has not exceeded one (7) year. If changes are made or if suspension or abandonmant exceeds one (1) year, full tees shall be paid for a new permit. (4) No work of any manner shall be done ihat will change the natu2l Flow of water causing a drainage problem. (5) Contreclor shall notify the Building Inspedor lwenty-four (24) hours in advance for all inspedions and shall receive written approval on inspection card before proceediing wilh Successive p ~b. (6) The issuan ermi e approval of mgs and specifications shall not be construed to be a permit for, nor an approval of, any violalion of the provis' ui g cs. er ordinance, law, mle or regulation. Chief Building Inspector Please sign Terms and Conditions on reverse side of page. COMMIJNITY DEVELOPMENT DEPARTMENT Building Permit Number: A° s BUILDING INSPECTION LINE - 303-234-5933 Date: CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 -(303-235-2855) ~~~~ICA TION PropertyOwner: V-01"rA C,n111.f ScAuA~fz) PropertyAddress: 76/SL,/. /9ae,OQ'11r LJA«O Oe'~~)0' Phone:3D~-~b6°/ODUXhT Contractor License No.: 4oC L/ 11y780 po ~'G CompanY Phone: 3p?-3Y9-G9/y ON'!iER/COKTRAC70R SIGNATURE OF tiNDER$TANDING AFD AGREEMEN7 1 hercbyccnify Ihat the setback disunca proposcC by this pcrtnii application are aaunte, and do not violatc applicable adinanccs, mla or rcgularions of the Ciry of Whcat Ridgc or cvvrnanis, caumrnl5 a restrictions of record; that all meuurertxnLS shown, and allcgationt madc arc atcunu; that I have rcad and agee W abide by all canditions pnmed on this appiiwtion and that 1 assume full myonsibiliy for compliancc with the Whw1 Ridgc Building Codt (U.B.C) and all other applicable Whpt Rfdge Ordinanca, (or work unda this permit. (OWR:FRxCONTRACfOR):SIGI:ED DA7E' ~AI90y (pw7JER)COWRACfOR): PRII.TED ✓ ~~~~QL~ 61 DATE ] /,t~d y DESCRIPTION: BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: 20NIN6COMYEN7E: Approval: Jq oK for weoli~u.Q 6cf1Ct or kharl Zoning: PL p evaoINO corrrrrs: LU A/J~ plR.(OQF~ ~~O S~Al d hY ApprovaL l. Pusuc WoRxs Correms: Approval: Occupancy: Walls: Roof: Stories: Residential Uniu: u Electrical License No: 7(5;1'7 Plumbing Licease IVOMtthanical Liceose No: CompanY:Z'.ncf c Company: Company: 9 N~sf/~ Expiration Datc: Expiration Datc: Expiration Datc: Approvalc 'gI ~~~pH Approval: Approval: ~ s+l s (1) Thu pmoit+ss issuad'm WcadaocC wiih the prvvuims M (pnp in your ypliwum asd u subject n the 6ws of the SaU of Cobndo and m the 7yoins RaluY6ms and BuiWins Codrs of Whpt RidP. Cobrado o anY Otho WpkaEk adiwntts of the Ciry. (2) 7LU pell shafl eapirt if(A) the work mi6onized'n od commenced rith4 siary l60) days (rom wue yts or lBl Uis bwldiny auUwriud is suayeoded w aWndoeea for a perwd of 120 d~ys. (7) If thu M+nit <npires, a new pmnit my bs `cqwrad fa a fa of ooe-half the mwum normall> ,e9wrtd Vm.ided m cluojes.havt beee or will bt made ie me mpiul pMns aod apecifie~Uws ~nd any sufpensim a~Wedo~mKO1 has op tuaed~d mt 1 abmdonmeat exceeds ooe (1) Yar, fad ka s1u0 Ee If cNo;es h~ve bem a i( suryauioo or pW (a a nsr permu (I) t:o wp} af any mumier sMtl bs dooe thu vi0 <Lro{e dhe mwn1/1o+r of ram nusvny a dnina`e prtoplem. (S) Cmeacv sW rorify tbe euldio` Inqwcv twm7fav (24) Aours io Wiivce f« W iospetbons aed s1u0 rtcen< wrinan appmnl oo inryetoon cW bdort Vroceeding with wttarive p6ves of the job. (6) The ismairce, of, D~~i1 a the apyp~l of dn.iep anA ryecifieauuu sha0 ep pe cpnpued b be a pemoit far. ~wr ~n approvJ of. ~ny viola4on o! ~hc pmnniows of de 4uiWin` c ~1ay pAn orduuoce, lzw, ruk a eeyuhnoe. ef BuilAino In<~ln. Construction Value:$ q7, 6z'o' Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ WHEAT RIDGE FIRE PROTECTION DISTRICT PO BOX 507 • 3880 UPHAM STREET • WHEAT RIDGE, COLORADO 800340507 3034035900 • FAX 303940-0350 • WWW.WRFIRE.ORG Barta & Associates July 27, 2004 30752 Southview Drive, Suite 250 Evergreen, Colorado 80439 Re: Tennant finish, 7615 West 38`h #B-I 15. The Following requirements are made under the 1997 Uniform Fire Code Adopted by the city Council of the City of Wheat Ridge, Colorado. 1. Illuminated exit signs shall be placed at every exit door. 2. Emergency exit lighting shall be supplied to every corridor. (This may be accomplished with "Frog Eye" lamps attached to the exit signs.) 3. Any use or storage of inedical gas within this unit shall be approved by the Fire District. 4. Fire extinguishers shall be mounted within 75 feet travel distance from any given point in the finished area. The eactinguishers shall be mounted 3 to 5 feet from the ground level. 5. Bathrooms shall be ADA accessible per City Building Department. 6. Any changes to approved plans shail be submitted to the Fire District for approval. Any questions regarding these requirements please contact the Fire District or myself. Res ctfully submi , Doug as J. aba Fire Marshal APPliwtion Date Permit No. ; ~ ` Wheat Ridge Fire Protection District ~ ! P.O. Box 507 • 3880 {dpham 5treet • Wheat Ridge, Colorado 80034-0507 2 303-403-5900 0ffice • 303-940-0350 Fax • www.wifiire.org rn , ~ a In rmatio SiteInformation ~ ~ ~ ~ t~act r ~ ~ ~ ~ Name: _ Address: 7 i/^~'> W , ju , ~ • . _ Agent: ' y qrVV.1 9 Business: Address: 4_;-(;1 X Contad: Phone: FaLT' ?3 6¢44°• &,9'lV Phone: , v f I attest the ~a6ove mformatlon to be ~accurate. I have recerved and reviewed ~ffie Indpection'COmpiiance and f.he Fee Schedule. Tliis pemit is Me ~ property of the YVheat~Ridge flre Protection District and is issued su6ject to mnditions contained herein. Upon any failure of any wndidon inGuding m ; failure of cieamnce of any pemit paymerct, this pemit is suqject to immediate revocation and the pemit must be retumed upon demand ta a representaNveoPtheWheatRidgeFreProtectionDistrick. c on Signature of Appli ant: V~,:r.r,, ' NOTICE:-If cnns6tiction is startetl prior to'khe issuance of a permiy TMRfE (3) times the normal fee wiil be'assessed. X TNSPECT7AN BY,FIRE PROTECTION DISTRICT REQUIRfD? 2"YES ' ❑ NO m . ~ PbsC2hLSyemr)tinaaonspkaousp/ace. RcquestrequiredinspectlonsaminimumofMreedaysinaduanreat303-4035902 h l h t ' I FEES I f d FORMUUI e s ee ) (see ee sc e u IYPE OP PERMIT I _ ~ of Tanksr - INo , ~ ~ ~f,y . yr b ~ a ~ ~ ' - Value- I Ystem Plans ISystem mi Rev ew At ~ ~ ~ SprinlderSystem Plans I iRewew ISystem Value= I ~ O I' I Review,Misc. System Plans ISystem Value=. I ( Date Paid IN,(►Revlew Suiiding'Plans IValuation= t.{ ei ,';7'Q$1 I b'$ 7: b~,?l kmL Paid ( 5 . S . m' LuSFerlat Handim9:ar Use Pians - , Naluation=; ' od TOTAL FEES DUE , I7.) 5 G`I ❑ 7otaf 81dg' J~~klteration C7;NeW O,Partial 0. ~,~It**qiydroStabCFestsand°Dates r"` ~ E Q ~ f[ v„ ,..u ,_n. u. . . ~f1h}_V. -•4f',!b de ~ 4..6:-..~ , ."1.._L :.,.Ip„~ ~I~. 1r, ` Comme,r~tr. , • PIRE PROTECTiON DISIRICT APPROVAL IS RE_ QVIRED PRIOR TO THE ISSUANCE DF THIS PERMIT. APROYEDASS ~ P"COND ON AP~~ erds } ..I f , TtTtE .~+'Jf~„w'.s~ DA7E ,rf rr ' ?YPE OF PERMiT ; I" r, FORMULA (see fee sc+edule sheet) I FEES A1 14t i.aa ISitLX;ASSL557i7@flt~R@'SY1bIn1~t0I~'".`iNOi~OfSiC2S^'° n~•," ~ :,,.,,d,•,,,~:,~„ , },Date P3idkrz, x J>•., pusx+~,. ~w2:. ' ' ~ 1PlanRevision'(Re-Iqspett) , ' INo:of-NOUrs IAmt.Paidl. ' ;iAfter MourS +nspecdon - 12-Hoprs + No. of Hours I- 1 1 Method L~ , : fFES DUBr: a PINpI;I►R .t~OVAL DATf E h ~ YW/mAW'.L.~LI~&Nd'G~ii'J~84V~~••Y-,,. t~ 1.:~ Yil~s1 a.n✓y~m? h.,..t '~I,YO:N~i15 ~ _ n.. cr~.S.M.•.YrVy` • ••••eysWelmJ:~: n•, c.~ BAcRTAr 4A550CIAcTF-S, INC. ♦ 303-674-3025 • STRUCTURAL DESIGN • SEPTIC SYSTEMS DESIGN 30752 Southview Drive, Suite 250 Evergreen, CO 80439 Fax 303-674-1889 July 12, 2004 JeffJacobs Jacobs Constmction Co. 5624 S. Andes St Avrora, CO 80015 303-349-6914 Re: 7615 W. 38m Ave. Wheat Ridge, CO 80033 Dear Mr. Jacobs, This letter will confirm that our office has made a site inspection and reviewed the 3-page set of drawings consisting of an existing floor plan, a demo plan, and the final floor plan for the above-mentioned proposed interior remodel. It is ttus office's professional opinion that the work that is being performed is non- shuchual and is not detrimental to the existing structurc. Feel free to contact me if you have any questions. Sincerely, te~ Ronald,E. Barta, President BARTA & ASSOCIATES, INC. lelOarobs_Ltr7615 Wep36thMe ~ f / ~a~YiV~ . ~ 4' ~1 l, ~ ~ ~ ~ ~ _ r C7 p \ ~ C ~ .A 'c r ~ N ~ ~ ~ ~ ~ r{~ ~G ' ~ ~ r ~~(r~Z ~ c ~ ~ ~ , t P,, . e G~ ~ ~ ' 1.t'"~ ~ c'-- n ' ~ O c- S~9 x,~0 ~S ~9 x ~e0 ~ I~ . ~ t U~ C~ 41 ,f _ t" ~`r ~ ~ Q I~~ 7 f~f / y,,,,,.r""- Ii~ J 1,! /E dl ~~i s7 / i4 ~~F i,r l~ fd V# V~ f f' ~ ~ ~ N o0 ~ i k rs8. ~ ~ !9 x i i ~ a i ~ ~ ~ ~ r i t i ~ ;r - :t i ~ ' a~~~a G+G J / ~ ` aa~a~ uL1iY /Vt uLiY~ oa~s~ ~ ~t~i~ /~V +~a~L+r~ 1 I i ~ ! ~ U ' - • ' ~ ~•,1 ~ ~ . IQ~~} n p1~7 ~H~/ i V f~7 ~N~ 1 ! ~ ~ ~N ~i ~ku rl ~N •1 i ~ ~ V ~ ~ ~'r11 t: ~ ~,f°1 tl' C C ~ ~ ~ ~ R'~+ e` `a ~ ~ ~ r 17V ~ 4~ / ~ ~ ~ - \ ~ f ~s ( ~ ~ .-'i~G i~~ /~ef'h i~' `R ° M ~ ' ~ C ~ ~ ' ~j n y n~ ' ~ r ~ ,„1 3 P ~it3 +7 ~atl x ~1 C~ ~ ~ ,E ~ ~ ~ ~ ~ ~ L ~ C ~ Q ~ ~ . _ ' ~ I_ N N ~ r~ , ~ r ~ ~ n , ~ p ~ n , ~ ~ X ~ ~ f t~ fJ d ~p . . ~ -a , t~ ~ „ ~ ¢s - , ~ , . I r ~ b ~ ~ ~ ~ ~ t '~'yr~ ~+r p 1 (yi~ ~j (,y i' ~yI i_. s ' V X V` P A'[/ X V r` C l r~ f~i Y s~ ra U M ~ ~ ~ ~ ~ , . , , f 1 4t ~ f 7f V f Pf / 1 f4 t ~ ft ~ ~ 9~6 2-2 3-0 ~5-5 2-3 ,d8'o9~~~{~,£` ~ ~ ; a~ ~ ~ r i ~ 4 ~ 1 0 i t r~ ~ ~ ~ , ,t _ ~ ~ , r ~ , ~ ,d.~- 44 -4 ~ ialli°~er7 ~ f,~„f ~~r 40 Ve~r~n /V ~~r~~iP V ~.{~~;'ro I/ ~r~t,+ae / ~ ~ L I ~ ~ ~ ~ ~ , s ~ ` I ~y I j'~t! ~ ~Ps[} i /jtl ~ H P'Vn A ~r`\) ~ /~ff y ~ M~1 Isf'~19 ~ ~_~N °ll J1 'tJ -t! ~t iJ I r € t# i/ ~ r~ 1 ~ i ~ ~ ~ ~ ~ ~ ~ ~ ~ - •ri u~ ~ , ~ ~ c r ~ , o o ca ~ cv iv • r°~ cv cv cv ~ ~ ~ ~ ~ ~ ~ I U~ ~'1 r- ir I lD - ~ j ~ . ~ ~ v r3 ~4 -~0 !l V ~ ~~Eac " ; ~ ~ - ~ 4 ~ C ~ . ~ o 0 .r ,e ~ ~ ~ ~ af i i~ 's~ r rf ( L °Q ) t C ~ (Q ~ .t~f po~~ I~s ~ , - • ~ ~ W ~a ~ w~ ~i ° ~ ~ a9 x~S'a ` . ~ ~ ~ f f}{~ Qr~ ~r ~f ~P~ It ti! I 1 ~7 7 f / " /ytd~ 1_~ r N~f V/ ~ d0 V~1 V/` '~M°• t.. ~ .F - ~ ~ i ~ ~ ~ i ~ ~ ,i i i ~ i ~ \ ~ i ~ t p ~ p~ ~ f t1~ / ~ V j ae~7 iY FtCf r~ ae~l~~Y tf I/ i ! ~ ry^tr / I ~ / u~ rY a~ i~ / / ~ ~ ~'L i ~ ~~ry \ \ ~ y ~''y p. y . ! fc,7 Ulf ! ) t~ d~ ~ Uy E ~~0,~ ~ e! uE.► i~ ,if3 e9 ia~ r ~ _ i s~ . ~ k ~ ~ ~ ~ ~ 1 ~ ~ ~ ~E >1 b~ ~ ~ ~ U1 O a1 L- +C 1 ] ~i V ~ . ( r a ~ ~ ` t ~ C I .e r ca - - ~ ~~w,..~. r I ra . ~ ~ ~ ~ I c~ ~ ~ ~ I ~ I I , {Jt~ ~}ro a ~ (,1 ~,J ~ e n e re ~ X ~ ~ ~ ~ I J~ry P (/~l II ~}1_ V t x~t !P ~ fI ~ W y ~ ~ - 1 ~ ~ ~ ~ i ~ ~ ~ „1 ~ / ~ ~t3 ~ ~ ~ ~ ~ ~ ~ ►~~~X o ~ ~ i ~ ' I -0 X a~ ; ~L"~~~ , ~ ~ ~ I o sf ~ 7~ ~ ~~1~jc~~ ~ . , ~ ~ C ~ G ~G ~ °V I 4P ~ f 1! , 1~-5 ~ 2-3 e~8;~ ~ c~ , , , ~ . ~ _ , C) ti: p ~ e~ ; ~ r ~E ~ _ ~ ~ ,f Ar Aia ~c~~ a~~ f Y +~qt` ,u^af / IfV iTlV ~ Q'"~ ~f 11 tI ~(~~i! I CP V 1~'#1 I/ f Ot ~ t i ~ T l i ~ ~ • ~ ~ ~ I ~ ~ 2 -6 ~ - ~ ~ ~~~r x 6 F ~ } , - ii~f r r ,~!My r ti r +~yji[7/ }~+~1r t n ~ A~~~ ~Y A~' ~4 A 4J~' i ( t If P y -0~ X 6 -0 X 6 -8 00 U~ ~ f rm ? M r-°~ ~ ` ~ i r,-~ ~ ~ ~ ~ ~t ~ " C : z ~ ~ ~ e , i CJ N ~ ~r ~ ~ N r- r. r ~1 E~i t""° ~r- eb i liJ ~ ~ ~ - ~ ~ ' ` ~ ~i . . , . . . ~ ~ ID~~P~ ~ 4--l ) ~a € m ~m m ~ ~ e O q ~ y N a' m a ~ ~ $m o ~m o .d. Q m 0 ~ m # E° Q c ~ a ~ c•~ z $ ~ o ~ U W d o $m W o 12 o ~ c~ ~ O $ `o o 8 ' 0 a ° °0 w O v i - o Q r- ~ Q ~ OS r q N ~ w W o aL ~ ~ ~ xN L) m3 3 D cr C~ 0 oK in $ m t ~ ~ ~ r r D~~ Uj 3 > m n ~ t7 N O o L y ~ y Y m j T ~ LL S~~E U ai m ~ ~ O ~ ~ N O a ~ W ~ ~ ~ y ° 2 OD M U of a~ m d ~ in ~ O m=t z ~ ° o °o A ~ 3 Q. N ry ~ N U) w Z 0 ? ~ a n`o ~ O d > O ' o E 8< < O ~ w Z E ~ $ ~ 1 w 0 2 E Z Z o O ~ ~ 0 a ~ ~ v O U a ~ `O m ~ m U N ~ ~ m =a a~ n~ ~ a ~U b ~ a$ h E O ~ ~ n 0 U .L. U C 0 9 Ey L l0 N ~ ~ U i d a c a 5 m O U s E $ N INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 234-5933 INSPECTION RECORD JOBADDRESS ~ ~ Ir) I. `1~~>`~` A-U C BUILDING PERMIT N0. I~~J Z' DA7E ISSUED ~i'~ TYPE OCCUPANCY OWNER ~ . ~ . ~ ~ _ ~ • C~ . .C +I G ~ y ~ CONTRACTOR 1 ~,(1Z~ SETBACKS FROM PROPERTY LINES: NOFTH SOUTH EAST WEST INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB INSPECTION DATE Foundations ~NSPECTOR Caissons Reinforcing or Monolithic Weatherproofing POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor: Electrical (Ground Work) Plumbing (Ground Work) ~ Heating (Ground Work) ` DO NOT POUR FLOOR UNTIL ABOV~E HAS BEEN SIGNED Rough Electrical Rough Plumbing Air Test Gas Piping Rough Heating & Ventilation 2q~ Framing ~ _ Q • Insulation D rywall Nailing ~ Roofing Refrigeration Electrical Underground Final Electrical Plumbing Heating & Ventilation Frame g - O,_o R.O.W. & Drainage Fire Department Parking & Landscaping e4 C t'+ik ` G OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUf'ANCY IS ISSUED PROTECT THIS C-ARD FROM THE WEATHER ~ -d l 'Ff_ COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 17170 BUILDING INSPECTION LINE -(303-234-5933) Date : 6/2/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: JOE JOHNSON Property Address : 7615 W. 38TH Phone : 8015760550 Contractor License No. : 21952 Company : Greenwood Construction Company Phone :(801) 576-0550 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the Cily of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Buildog Code (U.B.C.) and all other applicable W h t Ridge ordina c s, for work under this p rm . (OWNER)(CONTRACTOR)SIGNED .Ve ~ - DATEb Description : DEMO PERMIT INTERIOR Construction Value : $0.00 Permit Fee : $30.55 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $30.55 Use: Zoning Comments:= Approval : Zoning : Building COmments: _ Approval: Public Work's.C4mments:' Approval : Occupancy: Walls BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Ri Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company: Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval : (7) This permit was issuetl in accortlance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Rid9e, Colorado or any other applicable ordinances of ihe Ciry. (2) This permit shall expire if (A) ihe work authorized is not commenced within sizty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this pertnit expires, a new permil may be acquired for a fee of one-half the amount normalty required, provided no changes have been or will be made in the onginal plans and specifcations and any suspension or abandonment has not exceeded one (1) yeac If changes are made or if suspension or abandonment ezceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural Flow of waler causing a drainage problem. (5) Contractor shall nolify the Building Inspactor hventy-four (24) hours in advance for all inspections and shall receive wririen approval on inspeclion wrd before proceediing with successiva phases of the job. (6) The issuance or the approval of s and specifcations shall not be construed to be a permit for, nor an approval of, any violation of the provisio iltling codes oran Inance,law,rule orregulation. ~ Chief ing Inspector Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: oF W"Eqrq BUILDING INSPECTION LINE • 303-234-5933 Date: ,.A o CITY OF WHEAT RIDGE ~ 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) `~~~RA~° APPLICATION Proper[y Owner. -JL' r" 4c. " o-_ / S~~ CS .5^C~ Property Address: ~7(p/ S C,: j;~ ~F-(' ~~n - 1' Phone: J GY' Contractor License No.: Company: Jnvd' OWNER/CONTRACTOR SIGNATURE OF UNDERSTANOING AND AGREEMENT I hereby certify that the setback distances proposed by lhis permit application are accurate, and do nol violate applicable ordinances, rules or regulations of the Ciry of W heat Ridge or covenants, easements or restrictions of record; that all measuremenls shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I me full responsibiliry tor compliance with the Wheat Ridge Building Code B. ) and all other applic ble W heat RidBe Ordinances, for work untler this pecmiL (O W NERpCONTRACTOR)'. / Description: ~ ` ~ ~ ~ Q ? o ! r, ~ ~ Sq.Ft.added Phone: SC)'~ 2,>2/ ~/.31,1 mstruction Value:$ Permit Fee:$ Plan Review Fee:$ Use Tax:-- TOt3l:$ DEPARTMENT USE ONLY ONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: ApprovaC PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Electrical License No Company: Roof: Stories: Plumbing License No: Company: Sq.Ft.: Residential Units: Mechanical License No: Company: Expiration Date: Expiration Date: Expiration Date: Approval Approval: Approval: Colo do and tolthe Zon n9 Regulatio s and Bu Id ng Codes of Wheat~R dge,ICob~ado or any o~the` r t a plicable ordinantces of Me Ciry. (2) This permit shall ezpire it (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the bw ing authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half ihe amount normally required, provideC no changes have been or will be made in ihe original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid tor a new permit. (4) No work ot any manner shall be done that vrill change the natural flow of water causing a drainage problem. (5) Contrac[or shall no6fy the Building Inspector twenty-tour (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding wiN successive phases of the job. (6) The issuance of a permit or Ihe approval of drawings and specifications shall not be construed to Oe a permit for, nor an appreval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. L ief g 0 ffiaal COMMUNITY DEVELOPMENT DEPARTMENT BUILDING WHEAT INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE RIDGE, CO 80033 - (303-235-2855) Property Owner: JOE JOHNSON Property Address : 7615 W 38TH AVE. #A-100 17224 6/14/2004 Phone: 801-576-0550 Contractor License No. : 21952 Company : Greenwood Construction Company Phone :(801) 576-0550 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of W heal Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditi s printed on this application, and that I assume full responsibilit r compliance wi e Wheat Ridge Building Code (U.B.C.) and all other applicable Whe idge orce or work under this p rmi~ ' (OW NER)(CONTRACTOR) Description : Building Permit Number Date Construction Value : $60,000.00 Permit Fee : $927.95 Plan Review Fee : $603.17 Use Tax : $720.00 Total: $2,251.12 Use TENANT IMPROVEMENT OF AN EXISTING SPACE X:a BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Zoning Coihirients: Approval : Zoning : i Sutl#ltng,Commenfs:x OK WI NOTES. Approval: CR Publia Works,GomFnents:' Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : 21999 Company :Mellor Electric Corporation Expiration Date : 2/28/2005 Approval : OKIKS Plumbing License No :19264 Company :Tony Capra Plumbing & Heating Co. Expiration Date : 6/16/2005 Approval : OKIKS Mechanical License No : 1 tt4yi Company : Diamond Heating & Air Expiration Date : 6/15/2005 Approval : OKIKS (t) This permit was issued in accordance with ihe provisions sel forth in yopur application and is subjecl to ihe laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) lhe work authorized is not commenced within sixry (60) days from issue date or (B) lhe building authonzed is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount nortnally required, provided no changes have been or will be made in e original plans and specifcations and any suspension or abandonment has nol eaceeded one (7) yeac If changes are made or if suspension or abandonment exceads one (1) year, full fees shall be paitl for a new permit. (4) No work of any manner shall be done that will change the naturel Flow of waler causin9 a draina9e problem. (5) Contractor shall notify the Building Inspeclor N+enry-four (24) hours in advance for all inspeclions and shall receive wrilten approval on inspection card before proceediing with successive phases ob. (8) The issuance il or pproval of d ' s and specifcalions shall not be constmed to be a pertnit for, nor an approval of, any violation of the prowsio ildi odes r an ance, law, rule or regulalion. ~ Chief Building Inspector Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT - Building Permit Number: ~ oe w"EqT gUILDING INSPECTION LINE • 303-234-5933 Date:/ : P'a CITY OF WHEAT RIDGE ~ 7500 WEST 29TH AVENUE W HEAT RIDGE, CO 60033 -(303-235-2855) C~~ORPQ~ APPLICATION Property Owner: aoe Phone: ~O/r76 O S~.S'Z7 PropertyAddress: f,,/ 1!5-1.~ 3 b'~~~'~F' aza -4441k Connactor License No.: y5"~ Company:Affr/eu+0oJ Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERS7ANUING AND AGREEMENT I hereby certify that the setback distances proposed by this permit applicalion are accurate, and do nol violate applicable ordinances, rules or regula[ions of the City of W heal Ridge or covenanls, easements orrestriclions of record; Nat all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on ihis applicatlon and that I assume full responsibility for compliance with the Wheat Ridge Building Code and all other appli bl~/ Wheat Ridge Ordinances, for work under this p~t. r / (OWNERHCONTRAGTOR)'. Construction Value:$ Permit Fee:$ Plan Review Fee:$ Use Tax~ T023l:$ (OWNER)(CONTRACTOR):PRINTED Description: ~WGY'~ ~ J Il?~-eZYSi1r'~--i/ Sq. Ft. added BUILDING DEPARTMENT USE ONLY ONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: O.R. . ApprovaC PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: j Residential Units: ~ Electrical License No~X I°4~4 r~Plumbing License No: !3l d 4OL ? Mechanical Ligense INo^ /F'~e Company:~isrnn,.A/t ComPanY:/4II uPc~ic Company:G~a~o•u~J•... ~ er G Expiration Date: ExPiration Date: Expiration Date: / Approval Approvah qpproval: This permitwas issued in accofdance with the provisions set forth in your apDlicatlon and is subject to the laws ot the Stale of Colorado and W the Zoning Regulations and Building Codes of W heat Ridge, Colorado or any other applicable ordinances of the Ciry. (2) This pertnit shall expire if (A) the work autho~zed is not commenced within sixty (60) days from issue date or (B) the builtlmg authorized is suspended or abandoned for a period of 120 days. (3) If this permii expires, a new pertnit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in Ne original plans and specifiotions and any suspensio fuliees shalbe paid io ea n~e~w permit (t ) year. If changes have been or if suspension or abandonmeni exceeds one (1) year, (4) No work of any manner shall be done that will change the natural flow of waler causing a drainage problem. (5) Coniraclor shall notliy the Building Inspector Mreniy-four (24) hours in advance tor all inspections antl shall receive wririen approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be constroed to be a permii for, nor an approval of, any violaUOn ot the Orovision o~uilding codes or any other ordinance, law, rule or regulatlon. 7 "C"~ ~ i ~~Na 'F~x Wheat Ridge Fire Pro#ection District ~ P.O. Box 507 • 3880 Upham Street • Wheat Ridge, Colorado 80034-0507 303-403-5900 Offce • 303-940-0350 Fax • www.wfire.org rn ~ , S.3nfonnation ° rwrr,e: a,daress: /j Agent ~ c. , i ~7. , v . ~•.:;G,i c ¢':T9<-~ BI1911ES5: . , . ~C2^a~w✓/yyy-„)~..[YY COf1t2Q- . •~.Y...- . . . . N M• .Y lf'p' . . . . . Plwne: 9.;1 S i Phone: " r.> > 7 t 3 ~ i attaR tM a6me hNasnutfen tn be aavw[e. I Irre recdnad aM reriewmd the tmpsctlon Compliairce and the Fae Sdbedula 7Ak PermK b the GI propnqr ot nrwn«t afQne Vire Protection wmta md b trswa wb9«tm anditlom canhinee nadn. Ipon any.falMre or anr condRion lndudWq rn i' 1~Ir6 d d~ of a~ De~k ~ tW 0~ bombimmbumtllVA"towocdion and tha Pwmkmmt 6e rehxnad uPon denud Ee a ? L,_, l/pTICE: Ifoonsthwthon bskalW.pior to bwance of a pemiit, THREE (3) tlmes the eormal fae wNl be asseaed. : nISPEcIzaN sr FME aROTEcrlow omMcr aEqutREoz ❑ rro m PGStCNsA~Xhrm~otaP~r, RM~~~~amininumoftlrcaedsysbiadva~xrat.~3-4A33RiZ . i~. : i~ p a RMiT ~J FORMULA (see tee sd,edwe eeec) FEES r: 0H .Of.l' _ . . m Plans sysft t R~wSysftm #~ans SysternVakie Plans Sysbem Vaiue= nS Valuation= Speilse Plans Ya1uatw= TOT1LL FEES WE ❑ !lS 5UBMRITED (~}~l~Y AMtQYM (See ~ ~ . ~ DeEe Pafd Amt. Method ~ . Initials 4 pt ~ ~ r x j' NS~. df lCt;~ DUE 1~ . ~E~: 1 : + { f^t ` " T3i1~ DAT~ '`k" ~r4 +`zF ~ , , . . WHEAT RIDGE FIRE PROTECTION DISTRICT PO BOX 507 • 3880 UPHAM STREET • WHEAT RIDGE, COLORADO 80034-0507 303-4035900 • FAX 303940-0350 • WWW.WRFIRE.ORG Greenwood Construction June 10, 2004 Attn: Vlaayne Kliewer 12634 South 265w Draper, Utah 56100 Re: Plan review for Little Caesars Pizza, 7615 West 38`i' Ave. #A-100, Wheat Ridge, Colorado. The following are requirements of the Fire District made under the 1997 Uniform Fire Code adopted by the City Council of the City of Wheat Ridge, Colorado. 1. Addressing of the property shall be visible form the entrance side of the building. 2. A business key shall be supplied for the Fire District "Knox Box" located at the building site. 3. Three sets of drawings for the required Fire Extinguishing hood system shall be submitted to the Fire District for approval. 4. Fire suppression system shall include automaric shut down for all electrical, gas and ventilation under the hood. 5. An extinguisher with the minimum rating of 40B shall be installed within 30 feet of the commercial cooking area, mounted 3-5 feet from the floor surface. 6. A fire extinguisher with a minimum rating of 2A40BC shall be mounted in the main waiting area of the business mounted 3-5 feet off the floor surface. 7. The Fire District requires a minimum 24 hour norice for field inspections. 8. The Fire District shall be notified of any changes to the approved plans. Any questions please contact the Fire District or myself. Respe lly submitted, Douglas J. Saba Fire Mazshal COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 77334 BUILDING INSPECTION LINE -(308-254-5933) Date : 7/6/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: LITTLE CEASAR'S (W ILMORE CENTER) Property Address : 7615 W 38TH AVE A100 Phone : 560-2190 Contractor License No. : 20870 Company : Inter Mountain Signs Phone : 303-456-0060 ACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT truction Value : $6,500.00 n OWNER/CONTR cation are accurate, and I hereby certiTy that lhe setback distances proposed by this pertnil appli r Permit Fee : $181.10 do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or ll measurements shown, and alleqations th t l $1 1 77 72 n Rev iew Fee : a a covenants, easements or restrictions of record; d accurete; lhat I have read and agree lo abide by all conditions printed on this re 00 Use Tax : ma e a application, and that I assume full responsibility for compliance wiN the Wheat Ridge Bw mg Code (U.B.C J and all other applicable W F~aetRi 9i a es,'f r work under this permit. ATE 1 7'6" (OW NER)(CONTRACTOR) SIGNED US8 : Description ~ INSTALL (1) , / O ON RACEWAY. (2) 9"X63" V NYL ON EXISTING MO UMENT~CEWAY BUILDING DEPARTMENT USE ONLY ZoniKg Cominehtss Approval : JH Zoning : PCD 6u1(dfng.CO'mmants;;: Approval : P,ubliC 111iCrk5'; Coeiri~ehts:' Approval : Occupancy : Walls : Electrical License No : Company : Total: $376.82 -t Cer~e..7r+R -LC:e7 (1) 3'X19'3" S/F PC LTR ~ ~ • ~Z SIC : 711104 ELECTRICAL MUST MEET 2002 NEC ART 600 Sq. Ft. : Roof : Stories : Residential Units : Plumbing License No : Mechanical License No : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : (1) This permit was issued in accordance with the provisions set foM1h in yopur application and is subl~ to the laws of the Slata of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the Ciry. (2) This permit shall eapire if (A) lhe work authorized is not commenced wilhin sixry (60) days from issue dale or (B) ihe building authorized is suspended or abandoned for a periotl o(120 days. (3) If this permit ezpires, a new permil may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in e original plans and specifcations and any suspansion or abandonmenl has not exceeded one (1) year. If changes are made or if suspension or abandonmenl exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done thal will change lhe naNral Flow of water causing a drainage problem. (5) Contrector shall notiry the Building Inspedor hventy-four (24) hours in advance for all inspeclions and shall receive wrinen approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval po¢f ~dravrings and sDecifcalions shall not be consirued to De a pertnit tor, nor an approval of, any violation of t e provisions of th 'Iding cod ordinance, law, rule or regulation. _ ie Bui ng In Please sign Terms and Conditions on reverse side of page. U• • APPLICATION FOR BUILDING CONTRAC70RS LICENSE City of Wheat Ridge 7500 W 28th Avenue Wheat Ridge, CO 80033 License # Z d o Expires: The undersigned affirms that helshe is familiar with the ordinances and regulations of the City of Wheat Ridge relative to building & construction within the City and shall at af1 times perform in compliance with same as a contractor under the class of license hereby applied for: Lic Claas/DeaCriotion Fee Lit ClasslDescription Fea _ ( ) Class 'I - Unlimited $150.00 ( ) Class 6 - Structure Moving $ 75.00 Class 2-- Limited $125.00 Class 7- Demolition S 75.00 ( ) Class 3 - Residential $100.00 ( ) Class 8 - Plumbing $100.00 ( ) Class 4 - $ 75.00 ( ) Class 9 - Mechanical $100.00 Non-habitable buildings and structures CarpoR Class 10 - Electrical Signal Prlvate detached garage (systems less than 48-volts) $ 75.00 Storege shed Swimming pools ~ CIasS 11 - Sign $ 75.00 Fences Siding Class 12 - Fire Protection $ 75.00 Fascia Soffit Class 13 - Lawn Sprinkler $ 75.00 Patio covers Glazing / Window5 (instaJ/ation and replacement) Class 14 - Roofing $ 75.00 Freming Drywall Masonry (none structural veneer only) E/evator systems ( ) Class 5 - Homeowner $ 75.00 •~~~~~~~~~~~~~~~I~~~~~~~~~~Y................ 4 . ~•'ou ~ z ~ !Cr~ S . .L J' "W~RSNAME <bC4 ✓YIER~'Z -r.rl~ BUSINESSNAME , 4 ~ I ~St+ tT1' Y4f_,V"✓- STATE CD ZIP U063 fO J C -w I ADDRESS S PHONE 363-us-b-00(e0 Fqx 303~'403-0~7~j C7vo4 -3L)G REFERENCES (3 other MunicipaVCounty Licenses): ~ti~~F~EI p Lic Lic '2B-G33G "Please Droveds couiss of licenses. Lic 13 35G ~ ••Pleasc nrovide a coov o/lnsurance. Applicant--- APPROVED BY Chief Buiiding Offlcial Signature t~ LO'd VS:Ti GOOZ 9 [nC LS8LS£L£0£:xej md 8 9NINNti]d OM~OFFICER INFORMATION SHEET Name(s) of owner(s) KwcSEU- Home Address Smi (o J~-~L1S6N Phone# 20- 450- 9~ 34- Driver's Lic. # 13 7 a iG ~ Name(s) of owner(s al Security # sHZ -y N -Li LN of Issue: CL) _ Home Address Phone # Social Security # - Driver's Lic. # State of issue: Name(s) of owner(s) Home Address Phone # Social Security # - Driver's Lic. # State of Issue: , Name: Home Address Phona # Social Security # Driver's Lic. # State of Issue: Signature: Home Address Phone # Social Security # Driver's Lic. # 5tate of Issue: Signature: Home Phono Social Securiry Driver's Lic. # State of Issue: Home Address Phone # Social Security # Driver's Lic. # State of Issue: Signature: £0'd bS:Ti VOOL 9 [nc LS8L5£L£0£:xej Md 8 94INNtlId Jul 12 04 08:40a John Hrawner Rscy Inc 303 4235855 CERTIFICATE OF LIABILRY INSURANCE Ameripn Femily Insurance CompanY O American Famih/ MWUaI Inarance Compeny if seleqion box is nol checkad. 6000 American Pky Madison, Wisconsin 53789-0001 Insured's Neme antl Atldress qussell Merkley DBA Inter Mounmin Signs Inc. 5616 Jellison St qrvaQa, CO 80002 AgenYS Neme, Atldreas entl Phaie Number (Agi./Dist.) Jphn Brawner (303) 423-2030 PO Box 70 prvada, CO 00001-0070 (1771304) This CertNicate ie issuetl ae a matter ot iMormpion only and eoMera no rlgMS upon the Cenificeie Nolder. This cxti6eete does nM amsntl, BxtMd or dMr the oovarege aMeMed 6y the pWicies RaNd Mlow. p. 1 COVEtiAGES e namaa aovn lar Ne poiiq pK~ietl inacaletl. nol~rAnsunaig any roQUremutt, itma a cmdYOn e' am w^kW a alner ms Is to unM met paxnes a ireurd~w Nutl M~ow nare Oeen bsveG to the nsure . 4 ~ti~~ pM CBrtli~ala maY ~a i~wetlat mry Po~aln.lhe Imu2nee eYaNOC Ey Ilw poYC4a tltleri0ed Moin WDjeell0 ell tho ~wTS. WY9oM, eM eandllo~mM suC~ pollnM ~m~ ~n ~pg~tp y yp~ CE POLICY NUMBER M~ E~ i~TpN LIMI'f5 OK LIA&LI7Y TYPE OF INSUpAN OadN wIW am PIapanY Oasrege Homeownersf Eace OCwIrv.a $ Nob~lshomwwners LlebGity eoary Niury,no v.oo~+r oamepo BoatownersLiabiliry Eau,otturbnce $ ,000 Botiiy „i W end Proparty oemege reila Liability eamo«um~ $ 'd~ artn WlryaPeno~a~LeMixy s '0~ ilit EaMOCCUrtenca y eb u o-in Fa~„E,,,poya,~ a v $ 000 Eam Oocumnca Sleiwory «u.+ pmaation and e,<n na1ae~x $ l~ a6ilily i F otreaea- ezn e~rvbrvo $ .0~ osaase-rm~.vU~:t $ ,000 G~al P9Yfe0ale $ 1.000 ~ iabilily ooneral proEUCmCanua0ooFaionsA 10000 c ialGeneral (ocarrence) XC7633-02-00 05 12)70/2003 1217012004 g 500 000 - Eo~a~~~ , 1 DO ~ 00 Pama n arom~soe nened w vou S Me4WEypc~col~ OMPBrennl S S OW $ .ooo Buaneasownen LiabAitY nyy,ayaiatt 8 .000 CcnxqnGeY6eumt $ 'wo LiquorLiabiliry Pppc9einumu $ .000 Automn6ie Lia6ility eae+vinWrv - EaenPersm $ 000 ❑ Any Auto emiy mlun - E+O amam $ .000 ❑ All Ownetl Autos $ 000 e o ❑ SGfieduled /tiloe , amag aropeny ❑ Hired Auto O NonownedAUtos eodyin~uryartlPrapeny0amagoGOmEIneEE ,000 ❑ Exc98sL18billty . - Eac~OCCUrrcn~empgreBa~e S ,000 ❑ Commerdal Blankel Excess : Q Other fMiscellaneous Coveraaesl ~ ~ 11151 }melntllvlNelprpanna~6vWwn uhsmoE OHoa ~Merewl . oESCWR~OUPFOPERI.TI N6ILOGAnqN9/VfJ1~C~~ . . . . WGMroEemiertOmemqqorovbrNlepW~y. ' tt pfo4uqy.(~p^IpI9,py OpC(alWs aegmgale is aquGt b ea[h . . . o[[unsnn imi eM a Y1dWPE In pOfiCy dQ~reg&e. CERT1flCATE HOLDER'5 NANE AND ADDRESS CANCELLATION . ShoulC eny ol the a6ave destribetl.pdicies Ge cex¢Il led bafore the de s) ' . ol Whea[ Ridge Ciry y ( ecpiraGOn CMe thereW the_company will erMeavor to mai re mail wCh lo the G~ertdkate Hddar nemedbut tailu ro e 75D0 W. 29th AVe. wNeen na ce notice shal impose no obligation o[ liadlity of any kiM upon the '70 daYs unless diffarent u t Wheat Rldge, CO 80033 ves. a mmp any, its egems or repiesen shown W d . ays numbe~ The v iwu mlhe~ i lrt el h 9 ~ 303-403-0779 F r nity ~ies ar e s ub1~ b con lation wi ~xnbed Polic cenc o ferms antl by the laws ot the state oi issue- q11E ISSUED ~ {1,+OyR~ F9 HEGy~tE ~ 412812004 ~ CeAifaate Hdtler ' S[ocK No. OBBBe Rev. 7102 U-201 Ed. 5100 r ~ m cn ~ ei H 9 eD y .~i (D c7 ~ m p N C O. Ct. < O = G. to. N ? ~ y ~ . 3 N O = ~T ( G) '0 ~ z \V ~ m ai Z (n N D~ C) z m ;0 0 ~ W . - 2 D 0 L p ~ 7 ~ r ~ ral/ ~ 0 Z ~ ~ G O ;O ~ D N • ~ ~ ~ mn 2 i~~ ii ip v ~ D y Z ~.n. ~ 0 CD J ~ 0 aT~ 0 ~ O ~ = CD o w o ~ : ~ ~ m K , ~ i w 00 ~ ~ aa f)~ ~ h< ? c W (D S m o 3 7 ~ ~ O ~ o m ~ ~ 03 ~Q , ~ 00 ~v! d o ~ 3 0 N ~ ~ O ~ <1, y ; m 1 D. a. (D C ' ~C-D -4 ~ CD ~ r' O f1 0 A V 0 A ~ Z N < o m ~ o Z ~ a Q D C ° o~Z o N D cf) w_ -1 Z D G) z a) z C) NNO~ D 8$8',g ~ 000~~ OPOoOo~J b 6 bi~ ap~ m l8i,g m 3 m - - ~ a ~ _r--' < . 0 a 0c? Wv N 3 ~ O ° ~o <D O ~ y M Ol .C ~ o(D~v (D Q ~ ~ x~ ~ : . g~ ~ ~ ~ ~ a ~CD O N ~ ~ o y 3 : N 0 A w w rn v r ~ r~ r o ~ ~ a `o' g ~ V1 y R A ~ C7 co r N r CD n..+0 O ro ~ O ~ ~ c z y ~ ~~C ~z z d °tl „ z ~C G~ ~ Q ^O z Y. •~D~n o ~ C~''t ~7 ~ m O F C fi,i ~ I.rl . ra. rn ~ EL I ~ cN0 D~p 0 ~ p I ~'DG m 41t?xi Z i v ~ ~ °om [ N A : yA CN ~ 4~^ ) c 9 ~ A ~ Q ~ D ➢ x V I c 4 " 2 ~ ~ ~ i~~ DESCRIPTION. MFGIINST(1)3'-O'x19'3" o.a.SIF LEiTER D15FLAY LET?ER5,p1 51ZE.36 il'Pc:PAN/CHAN REiURN EDGE/pEPTH/COLOR: Fh;EICOLOR5:#2V9"O9ANC•E'PLEX w/OUTLIPIE"BLALK' ViNI'L TRIN LAP/COLOR5:1" STD /"6LhLK' LIGHiING/COLORS: CL=AR RED NEOH 145TALL FLAT LO BLDG FASCIA SURFACE ELECTRICA:SUPPLI': vAC amps DESLRIPiION: MFGIIN5T(1)2'2"x14'-0" o.a.5/F LETTERDISPLhY LETTER5:11 SIZE 26 iYPE PAN/CHAN REiIIRN EDGE/DE?TH/COLOR: FALHCOLORS: #2119 "ORANGE' PLE%w/OUTLINE "SLACK" VINYI iRIM CAP/COLORS: P STD /"BLAGK" LIGHTING/WLORS: CLEAR RED NEON INSTALL FLhT i0 BLDG FASQA SURFACE: ELECTRICA! 511PPLY: vAC amps 2924 PENNSYLVANIA AVE. .,.....m..._...,._. ~ m _ . . OGDEN, UT 84401 1-807-621-4612 7-800-640-4612 FAX 621-8858 i I 31~ -6~I I I 14~ ~ I CITIf UF 1NHEAT RIDGE, COLORADO COMMUNITY DEVELOPMENT DEPARTMENT SUILDING INSPECTION DNISION 7500 W. 29TH AVE., 80033 -(303) 235-2855 Gon#ractor's License Company: Inter Mountain Signs Address: 5910 Ingalls St. Unit A City: Arvada State: CO Zip: 80003 Type of License: Sign Contractor CityLic: 20870 Phone:303-456-0060 Fax: 303-403-0779 Date Issued : 7/12/2004 Expiration Date : 7/12/2005 CHIEF BUILDING INSPECTOR Note: Inter Jifountain Signs 59107ngaCCsSt. VnitA Arvada, CO 80003 oa w"Eqr COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE- (303•234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE ~o~oRAO~ WHEAT RIDGE, CO 80033 -(303•235-2855) APPLICATION Property0wner. L irrcE C~rtsawS,J~ ~ 7 PropeRy Address: ?(p l.- w, 3C~~- IG(f) 10 Conhactor License No.: Z 0 g-J 6) Company: 7"g~e- W/ou.K-r.•+,•j pWNERICONiRACTOR SIGNATURE OF UNDERSTANDN7G NMDAGREENEM 1 hereby cer6fy that Ihe setbadi dsta^ces PrWosed Oy this permil applkation are acarate, and do not violate appli[abie ordinanoes, rules or re9ula0ms of the City of Wheat Ridge or covenanls, easemenis or restric6ons of record: Nat all measu2men6 sMwn, an0 allegatiais made are aau2le: Nat I have read and agree to abide by all condifims pfinteA on Ihis appfKaUon aM mat 1 assume fuR responsibiliry tor compliance wM the Wheat Ri09e Build'xg Code (U.B.C) and aA oN7A~z~ ces, lor work under ihis pertniL onre ~o - 369y (OWNEftHCONTRACTORj'. SIGNED F (ONTIER)JCONTRACTORj'. PRINTEDATE Building Perm it Number. Date: Phone: Phone: 3 03 Construction Value: $ (o5-00' Permit Fee: $ Plan Review Fee: $ Use Taac: $ I Total Fee: DESCRIPTION: ~1 r"s*'~'u, y Z~ ~ IZ ~o'/z `~7~,,, c,(,,.-.,,.,a.l lclk- S~a^ v'" ~[''c6`^''"`~ (1 ~ 3,)4 PC I ~z) Ri~~ t0,3It~ Ilivvv/ on/ USE ONLY SIC: Sq.Ft: towwerns: -7' 1 /04' ~ Approval: J 4 zoning: PCp BUN.WNG CpAMENTS. Approval: Pueuc waucs CarEHrs 0 I - . __-y-s Approval: Root °'cries Residentlal Un ts. Gccupancy Wzlls- ` Eledrical License No: tPK Plumbing License No: Mechaniwl License No: Company: Company: Company: yvie1l~ Ec.~tt~ Expiration Date: Enpiration Date: Expiration Date: Approval: APProval: ApProval: TAit Dermit wat ItwW M accordna wMh IM DmNfimt ad MM M your WWkalb^ and b tublM W Me Iewt ol Ue SW ot CWOndo and to Mf ZonMy RpuWions anA BW16n9 Cada oiNTul RidP, Cdad° or mY otlw iDk" adnances W the CMy. (2) ThN V," thall uVkv N(/a Ne wak wtlwrluE 1s W comMnud MNin slrtY (60) daYs han iswo drto w(8) 1M 6uiIdIM wNaliM is w WmGO a aDUWOmd for a pwbA W 130 Arya, (3) y~+p.~xc+uon. ra +nr ww«~aa~ ,wnamm.m en~ a..ac..a.d m. (~~no~ "cnr~ya haw ww « x ww~^~o~ «,b ~,~eo~m.n~ c«a.~1) 7m. M fiw MaM M D+b br a nw VrmL (4) No worM dm1 maroie fhall M done tlul Ml chanW the naWnl Tor o/ wrtar ausinY a MNaW DroWM^. (y) conu.cwr snr nwury m. euxanu Fsvector two^M110vor (241 nows m w.m<e ior ao MsvKtio^• a^a .nr receive wan.a appmd on i.voctlo^ c,ra eda. prucoodnp wNA saanWe duesa d the )ob. TM luwna a a pmi a the +Opa,y pf y+mi^ys ry yKMkations shaM nwl be conprvM to W a pumit Iw. mr n ppmd of, my ridatlon ol the p.o+hbnt (6) the OuidhW mAa a mY oMa ar9nana.lar, rvN or rWWWOn. Chief Building Inapector 65' -0" 33~ a>~ 6 pp,~ n ~ m (1 N x Z Z " s ~ ~ ~~m F'ZN y A ~N ~ c 9 ;p S Q DESLRIPTION: MFii/IN5i(1)3'-0- s19'-3' o.a5/F LETTER D15PLAY LEIIERS: ki SiZE:36" il'PE.PAN/CHAN RETURN EDGc/DE=ii1/CO'.OR: FFLE/L01GR5:&2119"02hNGE"PLEX w/OUt_INE'BLACK" VINYL TRIN CAP/W LOR5:1" 57D /"BLTLK' LIGHTING/COLORS: CLEAR RE: N'cON INSTALL RAT -10 3LDG FASCIh SURFALE ELELTRICALSUPPLY: vhC amp5 DESCRIPTION: MFG/IN5i(1)2'-0 "x12'-10'h' o.a.5/F LEi`ER DISP! AY IETERS: Ci 51ZE:24' 'fYPE PANICHAN ° FENRN EDGE/DEPTH/CO! 02: FAGEILOLO.Z5:x2119"ORANGE'PLEXw/OUTLRL="BLALK"VINYL C£ y rt T IM AP/ OLOR5 1' STD /"BLALK" 6 z y : R C L 11G4iING/CO.095: LIEAP. RED NEON c M f INSTALL FLhT TO 3LD3FASQA n ~ SURFAGe ~ N ELECiRICTLSUPPLY: vPr amps 37• -6" 12' -101/2" 19' -3 IA AVE. OGDEN; :UT 84401 . 1 ~ ~ 1-801-621-467 2 1-:800-640-467:2 FAX 621-8858 2924 PENNSYLUAN 4's~o ~ nPo N ~ ~ m ~ v z i ~NYr ~rOm ~'?N D o A ~ Q ~ D d F " ~ m Z ~ !i ~ y c c 63" ~ ~ r ' + DESCRIPTION: MFG/INSTNEWTENANTVINYLSONEXISTD/PILLUM PYLON DISPLAY COPY/COLOfC: (LITTLE CAESARS) "OftANGE" 230-44 w/ OUTLINE "BLACK" VINYI INSTALL <A5 SHOWN> ~ ~ . . : . ~ , P 2924 PENNSYU/ANIA AVE. OGDEN, UT.84401 7 801-621-4612 1-800 640 4612 FAX 621-8858 ~ ~ JUN-24-2004 11:28 , 3~T~ ~ la r►'Ic ...V7a ~►s-'as fQ MI 3A"-J ~~c SA~ Z q✓n,i.ry(e O ~s-,J 4.AS V. o. INTERMOUNTRIN SIGNS 8016214612 P.03i03 walp~ Cw kG-w*-2t 6&1;J ~ 7~rs-~7~~ ti►•38''~C~,+v~ Ir' SoFF~s- ~w+~ \ 9 yz fo~esr 6~- 2rvcsw~.~f. G.J r-m S tir a . TOTRL P.03 v ~ 1 ~ 7 N ~ ~ 0 , w:2; os w na (D A n ~ O W n W O 3 N S N < (D 6 N 7 N a CD C) 0) v ~ N A M 0 ~ ~ C- 0 Q a a N N D I n 0 5 3 ~ C 0 ~ Z ~ ~ -4 ~ W 3 ~ n W v G W~ m ~ • r O Z N ~ 0 o m rol, ` c y ~ ~ o' o :3 m ~ ~ Certificate of Completion AND/OR Compliance CITY OF WHEAT RIDGE 7500 W. 29TH AVENUE WHEAT RIDGE, COLORADO 80033 THIS CERTIFICATE VERIFIES THAT THE PROPERTY DESCRIBED BELOW, DOES COMPLY WITH THE WHEAT RIDGE BUILDING CODE, ZONING AND OTHER RELATED LAND USE AND DEVELOPMENT LAW S OF THE CITY OF WHEAT RIDGE FOR THE FOLLOWING PURPOSE. PERMIT # 16908 Minor Tenant Remodel OWNER: AQent Western Centers. Inc. ADDRESS: 7615 W. 38thAve. #B-125 PROPERTY ADDRESS: 7615 W. 38`h Ave. #13-125 Wheat Rid e CO 80033 CONTRACTOR: Miller Construction S ecialties Inc. DATE 5/12/2004 CHIEF BUILDING OFF ZONING ADMINISTRA P INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 234-5933 INSPECTION RECORD Joa nooAess V~) t,J TYPEOCCUPANCY BUILDING PERMIT N0. J~CCI O DATE ISSUED -A~~~ OWNER 4-4I OC d4~ 1-- Y"\ 0 CtA ±C 1LC. . ~ C. CONTRACTOR, C . SETBACKS FROM PROPERTY LINES: NORTH SOUTH EAST WEST INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB INSPECTION DATE INSPECTOR Foundations Footings Caissons Reinforcing or Monolithic Weatherproofing POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor: Electrical (Ground Work) Plumbing (Ground Work) Heating (Ground Work) DO NOT POUR F100R UNTIL ABQVE HAS BEEf~,§IGNI~D Rough Electrical f ~ (J Rough Plumbing I Air Test Gas Piping Rough Heating & Ventilation Framing ~ '6 r Insulation Drywall Nailing Roofing Refrigeration Electrical Underground Finat Electrical L ,s-(,-O4 Plumbing Heating & ventilation o Frame v: ~ \ d Sc- -13ro R.O.W. & Drainage Fire Department /2 ~ y a Parking & Landscaping OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ib' COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 76908 BUILDING INSPECTION LINE -(503-2345988) Date : 4/8/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: AGENT WESTERN CENTERS, INC Property Address : 7615 W 38TH AVE #B-125 Phone : 306-1000 Contractor License No. : 21725 Company : Miller Construction Specialties, Inc. Phone : 690-8507 OW NER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $23,359.00 I hereby certify that the setback distances proposed by this permit application are accurate, and Permit Fee : $490.50 do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Plan Review Fee : $318.83~ made are accurate; lhat I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Use Tax : $280.31 Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permil. Total: $1,089.64 (OW NER)(CONTRACTOR) SIGNED DATE Use Description : MINOR REMODEL - TENANT FINISH - NO STRUCTURAL BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : Zoning : Buildinge,.Coinrril OK. Approval: MS Puw1kwo' [wCia'AP$!~~~ Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : 18821 Plumbing License No : Mechanical License No : 18820 Company :Solo Heating & Company : Company : Solo Heating & Electrical, Inc. (elec.) Electrical, Inc. Expiration Date : 2/28/2005 Expiration Date : Expiration Date : 8/5I2004 Approval : OK/KS Approval : Approval : OK/KS (1) This permit was issued in acwrdance with the provisions set torth in yopur application antl is subject to the laws of the State of Colorado antl to the Zoning Regulations antl Building Code o( Wheat Ridge, Colorado or any other applicable ortlinances of the City. (2) This permit shall expire if (A) the work authorized is not commencad within sixry (60) days from issue dale or (B) the builtling authonzed is suspended or abandoned tor a period of 720 days. (3) If this pertnit expires, a new permit may be acquired /or a fee of one-half the amount nortnally required, provided no changes have been or will be made in the onginal plans antl specifcalions and any suspension or abandonment has not exceeded one (i) year. If changes are matle or if suspension or abantlonment exceeds one (1) year, full fees shall be paia for a new permit. (4) No work of any manner shall be done that will change the natural Flow of water causing a dreinage problem. (5) Contractor shall notify the Building Inspedor Rventy-four (24) hours in atlvance for all inspections and shall receive wntlen approval on inspection card before procee0iing wiM successive phases of the job. (6) The i ance of a pertnit or the approval of drawings and specifcations shall not be wnstrued to be a pertnit for, nor an approval of, any violation of the proo~ ofOt~ I1uj~fiJp co~ s p~ny other ordinance, law, mle or regulation. ~/~/~L62 ~ 4F Chief Building Inspector Please sign Terms and Conditions on reverse side of page. oF ""E4T P COMMUNITY DEVELOPMENT DEPARTMEN f : o BUILDING INSPECTION LINE - (303-2345933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE ~ot oa~o° WHEAT RIDGE, CO 80033 •(303-235-2855) APPLICATION Building Permit Number: Date: 4~ES~ ccnrit~ Property Owner: -g i IM~ ( 503 ) 306-lao% ~N'"(Property Address: 3g4krNE * 5-~ 2-5 ConVactor License No.: Z ~?Z;~) Company: ~ptL~~7ZCzN5'~: W0C'0'1`f`"iVC5( JNC, OWNERICONTRACTOR SIGNAiURE OF UNDERSTANDING AND AGREEMENT I hereby cerGfy Nat the selback datances Proposed by Mis permil aPPlicaGon are aaurale, an0 tlo rwt violate applicable ortlinances, rules or reguWOOns ot ihe Cily of Wheat Ridge or covenants, easements a restrictbns of reoord; that all measu2ments shown, and allegations made are acarate; tl+al I have read and agree to abide by all condilions printed on this app6caUOn and ihal I assume full responsibiliry for wmpliance wiN Ihe Wheat Ridge Buildirg Code (U.B.C) aM all other applicable Wheat RiOge Ordinances, for work under Nis pertniL (OWNER)(CONTftACTOR): ol /na-q- sctfWettizTZ x c8 Phone: Phone(3o3) 690 •-0507 Construction Value: $ 2 3~3 7 R Permit Fee: $ 'V`io SU Plan Review Fee: $ V8 F-3 Use Tax: $ Total Fee: $ DESCRIPTION: hh) kro(I R-ErikL'UEL - 'j0JPTr'-i NC, BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: 20NIMG COMMENTS: ApProvaC r Zoning: BUILDNIGCOMMENTS: APProval: y~~ ~ pIIBLit WpUCS COMMENTS' ApprOVeC . Occupancy: Walls: Roof: Slories Residentia nits Eledrical License No: ~ 2 i Plumbing License No: Mechaniwl License No: jk $ 2 0 Company:So4n+q& aE7Asc- company: rv11ilr a.v~up°~q'JVw n~~ ~ i-~~ Expiration Date: Expiration Date: Eupiration Date: Approval: APProval: APProval: (7) TMS pwmM w» MuM in xcordanu wNh Ne proHtbna sel MM In yaur applkatlon md Is wCjeW to Me bwf of Me Sbte of Cdaado and to Me Zonlny RepulYlans Ne euikgno caaa avm.x wdo., caonao amy an« .vvuwN wammm a m. cay. (2) rnb vannift .nap aql+ p(A) me work wmorr.a is na caarn.z.a wxnm .t.ry lwl e.ys nom bwm are a (s) n» twkhoy awnoriz.e is wsome.a w ae.neo"d ror. q'bAWil00m (3) M tlds Vwo; aDt++, a nwv DrmM m+y be +ryukW la a iw d ane-half Me amoum nrornW1Y MuYsd. DrorMM no chan W+haw Mm a MP M mMe In Me orfpinN qans aiM apeciM1Ctlkns and +nY w Wmsian a aWndonment has nwt acoMM om (1) Yar. M chanpn haw Wn «N susvon+im a aWndonmsnt ac«dk me (i) rir. NW hn shY a V+b br i new Y!rmK. (I) No wart d any mmur NY G doee thal will cnanW the nYurY Ilow olwnr ausinq a drdnape proDlwn (5) ContraMOr sAY naqy Ne Bui1Mn9 InsWctw NmW-fw (24) houn In Wrance ior atl NsMtb^f and MaY racWe wrMm aVWmY on NaPoction urd bdm popMinp wMh waasiw Mnes dMe JoE. (6) 7M IswaMo d a pwmYt a Uie apprrnd d drawin9a mA spedecaliom fhall nd 0< consWeE la Da a pemiM lor, nw an approral of, any violatlon ol Me proviabna of ' Ihe buNdinq <odea or any othn ordin>nce, bw, rule or regulation. Chief Building Inspedor j ~ , } ~ Permit►do. APplication Date: ; ' ~ J~; ~ t t: l Ridge Fire Protection Disfrfict Wheat ~ . . P.O. BoxS07 ° 3880 Upham Street • Wheat Ridge, Colorado 80034-0507 ~ 303-403-5900 Office • 303-940-0350 Fax • www.wrfire.org m r ~ i Contractor %nfermatioo- Site Information NameABtlLEit C,3r4S7 $(~~C04-i'Ie5 ia+C Address: '9G#15 W, *38>Ng'~'J-f25 ~ - Agent: . e:s/.Za2~C."F.' T .P/Yie..4:t~. 44.. ' 9?'~~AY7~ .~'-bf+tJ" L~INt !'L „ Address: 170 Q>!6-t.oc.aa NA-aaa: ~W.2-[lOBusiness4N@'S"t~'9'2.tV CtFNWAa. fN.,' Cb 80,14 Contact: m'Jts9Alr- af h'P-+lAif'-'r.Z' o-y Phone: 3 0 3, (a `I 0 ~ ~ 0 7 Phone: ~0 tr~; w : ~0fm M l 8l9o - :a;" /cg ~ ~ I attest theabove information to be acwrate. I have received and ieviewed the Inspection Compliance and the PeeSchedule. Thisqermit is ihe ~ of the Wheat Ridge'fire Protection District and is issued subject toconditions contained herein. Upon any faiWre of any condition induding rn failure of ciearance'of any:permiE paymenq this permit is sutiject_to immediate.revocatianand4he permit must be retumed upon demand toa Y representative of the Wheap Ridge Fire Protec[ioo Distn r ~ - ~t+. Signature of Applicant: 4~A~~'"` . ~ . . . . , , b~i NOTICE: If construcEion is started prior.to the issuance of a permit, TNREE (3) times the normal fee will be assessed. ~ INSPECTION BY FIRE PROTECTION DISTRICi REQUIRED? X,,YES ❑ NO P41 Past thispeimit7n a ronspinrous plarn. Request required in5pecpons a minimum ofthree days in advance at303-403-590Z. TYPE OFPERPoBI'f' ~ JTank Inspedion. I Review Alarm System Plans I, iReviewSprinkler System Plans I IReview.Misc. System Plans ~)QReview Suilding Plans [Special Handling.or Use Plans ❑'Total Bidg, ~ Alteration I fORN9ULA (see fee schedule sheet) I PEES ~ iNo: of Tanks= I J :ISystem Value= I ~ JSystem Value= J I ISystem Value= , I ~ IValuation=CCN5 r' ^W, 21,-36,V. 0 0 I9 ~,0.1C4 I iValuation= ( ' 1 I. TOTALFEES -DUEI'~ i.:,t'cl I V t 0 I Date Paid 14 I;- { Amt. Paid S + ~ ~ Method ~ ~ ~ Initials F~ 0 z . " [I New ❑ Partial ❑ Okher: field Inspe¢ions and Dates Hydrostatic Tests and Dates: c, Commentis: _ FIRE PROTECfION' qISTRICT APPROYAL IS REQUIRED PRIOR TO THE ISSUANCE OP THIS PERP9n. 0 APPROVED AS SUBMIffED y ❑<CONDITIO~}~iLLY APP D (S,:CommSnTs.) J ' ' BY .af'YFsG~_ T1TLE- DATE 7YPE OF PERM1T MSite Assessment(Re-SubmittaQ j IPlanRevision`(Re-Inspect) 1,1 -JAfterhoursinspection' PINAL APPRO!/At 8Y ' I- PORMULA(seefeeschedulesheet)~ IfEES I INo. of Sites I I Date Paid I iNo. of Hours Amt: Paid 1 J2 HOUrs'+ No. of Hours I - ~ I Method I I TOTALFEES DUE , 1 I'I Initials I - 71TLE - . . -DATE " ~ ~ ~ ~ ~ v m 1 ~ . v , . U~ 03 v Z4 59~3 ~T ED TMEN ~NINRIDGE T OF PLAAfN T BUtLD1NG INSPVGTIOtd L CITY ~SW29 H AV3d3U235-28551 7500 W ~►5 - l WHEAT RIDGE, CO S02 PropertY ownef : property Address License No 7615 38th ave, a-~00 18995 GOMMERCIAL guilding Permit Nu, Date : Phone . 414100 Phone : 286-'~965 gg,5~0.00 Construcfion Va~ue'. ~.~g7 25 permitFee'. $0.00 plan Review Fee'' $127.56 uSeTax~ $294.75 Total Contractor ComPany KASC p~~G pND AGREEMENT urate, TRAGTOR SIGNATURE p~ UNDFRSTAN d~siances P~op oree9ula8uns o,he Cp Y°,Wheatdaeg8h °s OW NERfCON o setback , rytes easuremBnts shonnted on teiBuilding t hereby cedjH that th licable ordmances , ~d. that all m ajI ~nditwns P heat Ridg e~mit, violate aPP or „e'tectead and e9ree to ab'dmPYance with the W ~der this P anddonotpasements„ n~litvforco_,; torworK caae k`,..- , gIGNr n (OWNER)ICONTRAGTORI alls ceilin9 and floor pescription ; interior dem° ~ncludin9 W ' ~010 "APprOval%'£ Zoning : APpCOVaI b9 ~ 00~ ~f APProval . Walls Occupan°y ~ E~ectrical License cQmpany ~ Explration Date : Approval . ' Use W~th apDUStical Ryplace 9rid. ceiling T USE 0N1-Y SIC gp. Ft. : TME~ gUfLDiNG DEPAR interior only Residential Units . Stories Ftoof nse Na Niechanicai Lice plumbin9 License No : ComPany Company ' ExPiraHon Date : ate : ppproval : FXpiration P do a~tptheZonin9 . ended or AppfoV81 ' faws af ihe Sta n9 aulharized ts Pl~1e "tion and ~i 5 obge Cilyne te of Co ° will suspbe made in tha h p~p ordinance iSSUe date ar lB~fiebuildicnaM19es have been ~ion or abandonmeni che pt°°~~rado o anY° ~n ~ew opur s aPMN (60) daYs from rovided ~ or if s~spe rcea p are maae (a) .~,.$'aationsand0unwrel4lA)th?worrcaw~_.. enr a fee of (2) ahandonedEOraF~„°_- e~mn,~w~- ~sw„°.- (3) on9 ~ae Plans a Pei~ afees shallbe yd'a for aa 9eqne eat, nethaFwl r( exceeds one (1)maMeihe Buildin9lnsPa~°.r ~~ty-5~ phases of the Wb' s and ~~acmr sh^SU~^ °S~ve aPPfovat of dr`w~ 1e or The Issua„ce of a p~otm~anorme ther ofdlnance, oi fie buildin9 ad" spectj6r ' Ghief Suilding 7- nt narmaiN «°ear. it chan9e5 fore e-hali Ne amou eded one (1) Y mval on insP~~~on card Ue Renthasnotexce aplem. 'pns o of the p~~°t5 fl~ f Wy~e~ causing a deainage p ro~~ o{~ any violation for all 'nspkttons and shall receiv? o°an apPP rs in atlvance ns~~ to ~ a PyrttiRfor, ,~rnns shall notbe ~ DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 APPLICATIo N Property Owner: Property Address Phone : Contrector License No. : Company : Phone : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ritlge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printetl on this application, and that I assume full responsibiliry for eompliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ortlinancesyjor work under this pertnit. (OWNER)(CONTRACTOR) SIGNED y~'W~DATE 3~3-J~6 /961' Construction Value : Permit Fee : Use Tax : Total : Use: Description: .1~.f lrZ~-rG f / BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : Zoning : Approval : 7G Approval: Occupancy : Walls Electrical License No : Compeny : Expiration Date : Approval: Roof Plumbing License No : Company : Stories : Residential Units : Mechanical License No : Company: Expiration Date : Approval: Expiretion Date : Approval : (1) This permit was issueO in ac~aEanoe vnM the proviaions aet kM in yopur appliwtion anC is au0ject to Ne laws of the State of Coloatlo anE to the .'.oninp ReguWtians and Builtling CaEe oi Wheat Ridqa. ColoreCO or any omer appllqble oiEinances ot the Ciry. (2) TOis permit shall expire K(A) the work auMOnzeC ia not wmmenceC wiNin eixty (80) Eays hom issue Eate ar (B) Ne builtling authanzeC is suspentleE or aCantlanetl far a penoE o! 720 tlays. (3) II Mis permit espircs, a new pertnit may be aCpuire0 for a(ee of ano-half the amount nortnalry repui2E, proviEeE no Uanges have Deen or will be m9Ea in the original plans antl spetificatlons anG any euspension w abantlonmerrt has not exceedeC one (1) year. II changea are ma0e or H suspension or aDanEOnmeM exceetls ana (7) year, tull lees ehall be paiE br a naw peimiL (4) No work ot any mamxr snall be Cone ihat will Uhange Me naN21 flaw of water pusing a tl2inage problem. (5) ConVactor ehall notify the Builtling Inspeclor twenry-four (24) Ipurs in advance br all inspectione anA shall receive written appivval on inspection mrC Celorc proCeeEiing with succeNive Pnaaes Of Me1'ob. (6) The issuan[e of a pertnit or tlie approval of OrowinOS anE specficatlons shall not Oe mnsVUeE ro be a permit br, nor an approval al, any violation o1 Me pioviabns a( the builEing m0ee or am/ oMer oMinance, lew, mle or repulatlon. Chief Building I pector KASCO Commercial, Inc. 6330 Washington St_, #10 • Denver, CO 80216 Phone: 303-286-1965 Fax: 303-286-0332 April. 4, 2000 City of Wheatridge Building Dept. 7500 W. 29th Ave. Wheatridge, CO 80215 Project Address: 38th. & Wadsworth Suite #A-100 Description: Interior demo, new 2"*4" acoustical ceiling, patch walls ready for paint. 0 / ~~dBl/ 'r~~ Ty~• ~i? 5 ~ me~V ~ ~ T~✓e ~Cezt2~iT TO ~MSTkI~ /~iviJ BUILDINC A A-100 Vrernl - 2.034 SF ^f M n , I ,8 I ~ MmAs I I ~ w•u 3em Av•o~o Certificate of Completion AND/OR Compliance CITY OF WHEAT RIDGE 7500 W. 29TH AVENUE WHEAT RIDGE, COLORADO 80215 THIS CERTIFICATE VERIFIES THAT THE PROPERTY DESCRIBED BELOW, DOES COMPLY WITH THE WIIEAT RIDGE BUILDING CODE, ZONING AND OTHER RELATED LAND USE AND DEVELOPMENT LAWS OF THE CITY OF WHEAT RIDGE FOR THE FOLLOWING PURPOSE: Build two walls and two small offices Permit # 10585 OWNER: Mountain Spring Plaza ADDRESS: 7615 W. 38th Ave. PROPERTY ADDRESS: 7615 W. 38th Ave. Wheat Ridge, CO 80033 DATE 1/24/01 CHIEF BUILDING OFFICIA ZONING ADNIINISTRATOR Building Permit Number : 10585 Job Address : 7615 W 38th AVENUE { Description of Permit : Build two walls and 2 small offices Inspection List Date M6 7500 West 29'h Avenue • Whent Ridge, CO 80215 Planning: Phone # (303) 235-2846 Parks & Recreation: Phone # (303) 235-2877 Public Wo^ks: Phone # (303) 235-2861 Fax: Phone # (303) 235-2857 DATE ~ /P~ ~C Nnme: Orgnnization: Fnx: Phone: _ Z~ From: 11~&L2 ~'Q Dept: Planning ❑ Parks & Recreation ❑ Public Works ❑ Subject: # of Pnges: (Includina cover page) ~ Comments: Original to follow in the maii ❑ Yes ❑ No HP OfficeJet Personal Printer/Faz/Copier Identification 93033201987 Resnlt -PAM T.7w OK 02 Sent Fax Log Report for DEVREVFAX 303 235 2857 Dec-13-00 03:41 PM Dagt TEM purafi4P Diasnostic Dec-13 03:40P 00:01:50 002184230020 zao IDate: 1125101 A Ce~i~~ate of OccuPancY or Co ~DR~ss: 7615 W.38 mPletion h th aS b~en requeste pURp A~enue Wheat Ridge, CO d for: OSE Of' .STn.,..,_ 80033 sma~ffices Building DepartMent Remarks; Zoning qpproval: Remarks; Public Works qpproval: Remarks; Fire Marshall Approva (if Applicable) Remarks; Sanitat)on District qp (If qpppcable) Remarks; Water District qpproval: (If Applicable) Remarks: z C W L r ~ M Q L, o~ p N a ~ . W M w ~ O Z ~ Q U ~ ~ ~ v > R rn aN ~ d ` O ~ C 9 A Z ~ ~ 7 N N O d c ~ L ' d 3 a L i - y ° C O O T ~ ♦ ♦ ~ y t Y V R A E ' lp y C p t ~ ` ~ L N ~ s c g 0 ~ 0 s 'S m' ~o ~ . 0 H p C m 0 ~ ~ L c10i W ~ > V ~ 0 ~ E W m ~ :~LD a H ~ od p O ~R ~ Z a y ` C Q d O L V ~ O N L ~ ~ 0 O LL v > c o m rn d y ` r N m ' - ~ E 4)« W V ~ in m W ir N a ~ N Q ~ = m o ci W ~ L' N t' W _ • ~ 'C O y M ~j M ~ O V .M... Q ~ ~ > ~J ` } ~ V C V i °L o 0 w ~ ♦ ♦ R p L Y v ~ y ~ E W ~ y = ~ J > " ~ t > a 0 c L Gl ~ V) w ~ o ~ ~ CO ~ - > m c a o rn~ 0 ~ d N Q w C - ~ y W L m w x d~ W L U ~ ~ O r= ~ W w ~ H O~ O ~m Z a `J O 0) LC G L ~ V d ` V ~ ~ 0 7 0 ~ r ¢ ~ ~ ~ 234-05933 "T OF PLANNiNG 03 g AND3E - DEPARTMENT GT~pN LiN CI1-Y pp WHEAT RiDG U1LDING ►NSPE VENUE 7500 W C~ g0215A (303-235-2855) WFtEAT RIDGE, propertY owner : PropedY Address License No 765W, 38th AVENUE 20672 Building Permit Nu" 5126I2000 Date : phone . 306-1000 Contractor any : DFG Comp AGREEMENT St~,NpTURE OF UNDERSTANDING AND ro osed by ~h~5 Permit City oE WheaC R~dge ° ~~E~t(CONT RACTOR ~tions rules or regulations of iheen _ ~~,~wn, and alleg I hereby ~~!fY that the ~b~e ordinancess p p. ihat alt me8all conditF do not vwlale apP or restrictlons of racore 'to and ah~de bliancz with' ants,ccurate; easeme tha~ ~ have read and~~?s9,lbifiry for ~~comp for ~ made coven are a ' application, and that t assume full res~ . and all othe~ app<<cable Wh?AR~d / ~pWNER)( d~n;n ce$, Gode (U.B.C ) CON~~TOR) SIGNED Y es Description : guild two Walts and 2 smalt off~c Zofii~i~s~~a!~~MI5" ApPfOVaI: Zoning ' ppproval . DG APpr°vat : Wal1s'. pc,cupancy : Electrical License No ~ 18474 CompanY - surkElectri~ Expiration Date . 2I2BI2001 Approval : (l) rinted on meat Rid9te guilding under this pe"it 412-736'6446 Phone : $ryp,200.00 Gonstruction Value ' $195.25 . Permft Fee $000 Plan Review Fee $153.00 Use Tax ' $348.25 Total : OATE7 `~l° ~G} Use: gU1LD1NG DEPARTMENT USE ONLY SIG gq. Ft. Yfle~s~~~tefor : l O~ee f~nq~We is cesponsibe loca~jng PTO~erty lines od COnsWCting impsovements ~nt s~ i~ and requice d develflP tion pyoved p onsible foc inaocutate infosma is not resp~ Set and anY ~nsttuc4ion 5126100 Build to co~ ~ity submttted ~ul g~e lfta i~0urateirfotmmation. emQ~% Residential Uni1s : Stories : Roof : Mechanical l.~cense No - plumbing License No Gompany Gompany * EXpiration Date : ate : ApProval'. expiration D App fOVBl ~ oi polorado and to tne Zonin9 f~h y~U~ anPpcatlon and is sub3eo1 to theoa `B, ~e b Sdt 9 authodzed Is suspended or ~e peen or wi11 be made in the he PrColoratlo or any other app~«~esQddyys from iss~e date ,~ge, noed w~trm Six~y e u{~~ providetl no ~anges ha. ~s~on of abandonme~t orized is not cort~~ ouni normallY 4 If chan9es a~e mad fee ~ ne-hafflheot e of rf suspe enod 04120 days. pj~yd f~~ a o atn ~oval on insp~10P ~rd 6etore This permit snan ene"" e~md may be ac9 ndonment has n exceede a d ~nag p r roblem ~ovisons One (1) abandoned for a PeSi ae~Finew Pcatio a a fp~e a~~°~~it.lu~l usin9 °f ~e p permit exp as and any ~wns and shall receive written ap oi, any {f tnis vlola~~o~ pr{ginat p~ans anC sp e the na Flow of watei ~ ermitfor, fwr an apP~al r fu~~ fees shall be p {our (Z41 ho°~ ~n ad"ance 10~ all imp' ezceeds ane Y~ ~ Inspe~or twenry- constNed to be e P pJO Wo,K of any manneitse BuIldi^gRe ~at wi11 c aR E~ifkattons 5ha11notbe (5, hases of fhe )ob. s and sp ~~aUOn. GOntroc ton sWa'n~suecesi ~ ne approval ot drl~ lg or re9 The s ua~ e°f a perm jhyf ordlnance, ts~ of the builtling cades ar an _ Chief Building lnspeCtor NN1P1G AND 0EV 34O 9`3 NT PLp 303 -2 p~ BU►LQ►N~ INSPE0TWHEAT RiDGEE CI ~EST $~T15 (303 235-2855) 7500 ~ wHEAT RIDG~: CO , ' E ste. A Propem owner . 7615 W 38 TH AV guildinJ ►'e" . propertl Address 20530 contractor LicenseNo.'. ,•Rama A~REEMENT Cor tpanY S,gn i'""'.►~G AND STANDIN a~cu RE OF UNDER rate, SIGNATU it appiicoi W gat Rid9e or ion at h and al e0 pWN~RIGONTRAGTOR toPpSed by this P omhe CitY 1 distanc nancesSNletl thatea~ame~y~IcAndiions~ a Rid9e}g01~dinB ~patthesetbaodi Work under th~s Pe~"'it. 1 herebY o violate aPps~ ob~estad~o a and a9 ee t iorbcomPyan~s f BUILDtNG DEP COMPUES WI SIGN CQDE do n easemen 1 have full respons~billty . y ocdman ~ACE.~.,,.... U$e , co enants, that utate pU~yTED T0 RAC~WA -assu pplical'on Gan ~nd ap olhe[ apPlicable Wheat R~d9 ~ode N.6.G.1 E~ L EZtERS M QtERl(CONTRA- TOR) SIGNED~-GNANN _ TALLING X14 SINGLE`f UgE 1T "AA TM~NT ~SE ONI.Y SqFt. . pescription' EXH16 gIC'. ~an4~~„ APPrO~al . M►-C zonin9'. PCR APproval BG putsft~~~x~~.~~It1?~ts.µ~ PWOVaI' Walls _ Occupanr-y E lecL tr~censeNo Gompany ' EXpiration AppC°val . (~~~qulaCons p oi,anifonetl k3) nli4~nslpk: O) (6) 1013a100 SEE A4 ResidentialUnits'. Ftoof pate : 1013114%J"" phone : 720-898-A13'~ 202-1128 phonp $4,127.0o onstruction Vaxue $11125 c permitFee'. $0.00 I Plan RevieW Fee'. $g1.9A U5e Tax ~ Total Stories . Nlechanical License ~ompanY ' plumbin9 ~-icense No companY ~ EXpiration ApprOval Expi[ation Date'. rova4. ~ ApP ~ ~ne z~l~ 5 of the Sta~e of Colora0o and to rized is susPended ar the lav+ np in the u~° e^ or Will be ~ment y~ oc lg) tm buitdin9 a atle p f susPansion or aba~ ~f ~ an485 ~ mede oai roval on ~ion card betore ~~an111~..-- half che amount ded one insp oY tne p~visions a f~ o{ one- ° apP nY vipla6on nt nas not excee ina9e Pr°blem. ~vow~ aba~on~ causln9 a d Uans snd sha11 rec° roval of, a Omit, ra t flo'+~ of water for all inspe itfor, nor an aPP ~f ~Zq, nours in aavance dto ye a pe m a^d SP ulaU ~ns shall not he c°nsVUe ; ot te9 DEPARTMENT OF PLANNING AND DEVELOPMENT Buiiding Permit Number.: BUILDING 1NSPECTION DIUISION - 235-2855 ' CITY OF WHEAT RIDGE Date ° 7500 WEST 29TH AVENUE WHEATRIDGE,'CO 80215 APPLICATIO'N' Property Owner : 5/575eS' 5-1JO0A2N °roperty Address . 7-/a /S 41, STF fi /Do2., Phone . 7,20 -898-//3/ ContractarLicense No.< ads'3~ E Company: 9Phone 303 al~~'//.Z() OWNERlCONTRACToR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : V/e2 7, Sp i hereby certify that the setback distances proposedby this~permit application are accurate, . PefRlit F8@ and do not vioiate apphcatile ordinances,.rules or.reguladons of the City :of VYheat Ritlge or . . covenants, easements ar restndions of reeord: thafall measurements shown, and allegations ~made are accurate; that 1 fiave read arM agree to abide by all contlitions printed onMis . USe Taz : appficatronjand thatl assume fuN IesponsibiMy for compliance wkh the Wheat Ridge Building~ . " Cotle (U 8 C.) and all other M54t.Rid e rtJi -.for work under this permit..Tot21 : (OWNER)(CONTRACTOR) SIGNED r DATE~"~ U58' " . . Description : /~-/x Iylf 7/eE .!-ETTF-e.5 /r/OII~ ra It ,B,T "/9 ! Approval : C1ULC Zoning : RD u Approval A~lpp APProvaL Occupancy : ' Walls c csI, SIC : Sq. Ft. : ~(4 ~ `~li Vr~; r~) . 0 C T 2 7 2000 Roof : Stories : Residential Units : fiectrical License No : Company : Expiration Date : Appraval ` (1) rnisParmitwasissuec Reguladons arW.BuiWi ..(2) ThiSPertMShaMexpin :atiantloneC Mr apenp (3) Iithis~pertnRPxpjrcg.a on9inal PWns antl.apn exceeds aie (1) Ymr;(4) No vroAC d arry manne . (5) CoM2QOr ahall nptiy: plOCEIMPtIg WICI SUCCQ (6) Tlre'issuance ota:pert a the ewwM ioass c BUILDING EPARTMENT USE'ONLY Ccm~lsgs ~tsnn co& . Plumbing License No : Company : Expiration Date : Approvai : xwAsans set tarth m yopur apqicrcadm uM is subjat Cobredo w airy Wm aPdiceble admantss of the :a isnot wmmmcea wiCtln soM (e0) days fram iretl lora~lee ot ono-7utt Me amount ianreiyrequ ~abantlanment has not eztaeCetl one~(i) Yee parmFt hargeNe ~tunl lbw oi waW causng a Oramaqe d1tY'b11I (24)110uf5 m a0!ldnCE hX 811 MISp8CfKK15 ~law:eulearegulation . . Mechanicai iicense No : Company : Expiration Date : Approval : lo Ne laws of Me SWte W Cobratlo aiM to the Loning . Ctty: . . . . ~ aate of (B) the buileirg autnaaea rs susperMeew . ued, pro~rided m diarges:tlave been ar will be ~rede m Me : . r ttchangesare m aEeordsuspensionttaffaMlonmeM. Problem. . e(M shall tecerve vrtit[en apqoval on mspec6on prG beMre a permM for, nor w approval of, arry violation W the pransions Chief Building In x f/ ~~B iT J ,v~U~ W~~OGyJ ~u1~L L~TE TiPiri~! GrJA~-~ -/UOT TO - Proof icr_51.57z~2'S Sogn-A-Fdaesaa These proofs are tor yeur approval. Plaase check them carefuily! We wi:l not proceed without a reply to th18 ptoof. 70 approve proof, please sign below and fax to 303-202-1135. QApproved: Date le9'2tid/> ❑ Make corrections and proceed ❑ Make cor ecbons antl send a other proo Signed 1 9 /J zo ' s7a,eE DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number :[()5,00!5- BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 qPpL1CATIo N Property Owner: 1v'I0v,~,q„V .5P/L1h/6 PCA LA «C 303 - 306 /G?yO Property Address : 7(0/ s w 387'y iqr/kA/UA Phone : kX7 i/ Contractor License No. : Company : LoAn) /nAn.T Phone : ~{/Z- 736 -65/q6 pWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the set6ack disiances proposed by this permit application are aceurate, and do not violate applicable ordinances, rules or regulations of the Ciry of Wheat Ritlge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate: that I have read and agree to abide by all conditions printed on this aOPlication, and that I assume full responsibiliry for compliance with the Wheat Ridge Building CoCe (LLB.CJ and all other applicable Wheat Riqge ordinances, for work untler this pertnit. (OWNER)(CONTRACTOR) SIGNED i1~4 ~ DATE Construction Value : /0,, Z,2o Permit Fee : Use Tax : Total : Use Description : .Uc). 1- 7) 2 teiA 1-t-5 A~ D Z 5.~7RLL o,<<tc.~,S' BUILDING DEPARTMENT USE ONLY - SIC : Sg. Ft. . . Approval: ~ Zoning RECEIVED Fj MAY 2 6 2000 APProval : 05 jubwd-MrKswom Approval: Occupancy : Walls : Roof : Stories : Resi Electrical License No : 1941741 Company : t3vek €LEC7".ue Expiration Date : 21-2 V/zd22/ Approval : Plumbing License No : Company : Expiration Date : Approval: Mechanical License No :N~ Company: Expiration Date : Approval : (t) This DeMId was iuueC in aCCO'tlanCe wiM tlhe Orovitiom Mt brth in yoDur aPdintwn and ia fu01ect to the laws af Me State of CobnEO and to Me :.onrtq Regulations and BuiWing Coas W Wfieat RiOge. CobraEO or arry otMr applin0le aEinancea of Me Ciry. (2) Th is pamtt shan expire if (A) tlhe worK auMOnzeO b not mmmenceE witnin sixty (80) Eays fmm iuue Cate or (8) the builtling authonzeC is suspen0ea or abanCOneC for a penoC M 120 Oays. (7) If itfiz pertnit expircs. a naw permit mey be aCpuireC tOr a ke of onMall Me amount nomWlty repuirM, provi0ed no Ghanges have Oeen or vnll Oe mWe in Ne oriyinal plans and fpetifintions and ury auapensian M aEarWOnmmt haa not uceeEed one (1) Year. II Wnyes are maae or il suspenaion ar aWnEOnment esceetls ane (t) year, NII feea ahall be paiC /or a new pemmt (a) No work of any manner shsll be tlone ihat will ctmnga tlie naWnl Ilow ot water nusinq a 02inaqe praOkm. (5) Contrattot shall nofily the BuilEinq InspeUa IwanN•laur (24) Mun in atlvanta kr all irupeCfione sntl ihall mceive writlen approval on inspeclion nr0 EebM prxeetliiny with auae3sivs Dlyyea W Me7'o0. (e) The issuance of a pertnit tt the appmval ol Erawinqs and spedfiotlons shall not Ce construe0 to be a pemtit for. nor an aPPmal of. arry holriion M Cie prOMabns a( the builtlior any aNer ortlinaue, law, iuk w reyulatian. ' G%/ Ssz'rg Chief uilding Insp tor 3d -6 7'-0''~ ~ A, PgOAjE TA~ l8 f~fF _ pgWA 7nEA ~14 #if C = DYP(A' G/f``ric !8I AFF G~. Dow., YZ" 4FF p,FLt,F Q w,.+ar F = Co,)a.,T Fo., A c,.J.,a QtlAD(OXA^',R~"plf+r) Ppv6"L /8•~ fFGF FLa'<ALc..T LiGN~ Z = DvPu+` C'Lt,,/ P.-'c~ ~~P~ay 18" b;i7ri^' F40.+ CEiU^~S 0 L ix F ~ ~o n ~ i T s- Z NE'"l CI AA y. OFF,iu s 3 S/B ME TAc sr/) j 5/~^ agywaGL F~ L C r Aa J. Cr 2 ^/[u/ o./ACI.S ,3 5~8 MhT.K STlJAS CCG ~AA ~ ~ ~ ~ F 4- 7615 ~v pAN ~ -L 3 8-T N Av~,✓~~ 1W,441 g, .o, ' S' o" g~-fl ~ 1 " 74 -0 65, 14~ A= PFIONE TACIC 18 f}FG zntA Yz° /iFf C _ D~~Le. (tlC/io 18" AFF p = D,,vuv eleit,;., Q.r,adr F = Co,~a~,T Fa.. G = QiAO(oOLANSR 'o") O„Pu,. GtI,A., apvr.2 ig., AFF N_ FLo~s~cc„T LrGN'r I = 6 apt" dLcAl P..,F~ !S" bb►'^' F.v.• C Er L~^~ 5 =3 L° O F ~ ~o 15'- Z E~ LC A pFF#~~ 3s/d rvu7,ac S~p" Dacc. ~+c ~ ,4 J, C? 3T Cr Z Nfu/ H./ALI.S, 3 5/8 ^hT^C sTVns S~d Acf w~[c, qAC acG ~6 ce"Ae~ , .o ' g~-tl 4 BG~n -0 ,f 14~ r- L 7615 ` OAN (P y IN14 4 ~ i ~ ; T., -7 -L 301 _6 7'-0''-~ A- ~ „ _ 0 C if Is~~i(v F . g ~o s A: p)4pNE TAC* l8 f~FG _ P~*"c 7ntA yz„ ~}Ff C = DY~LfiY (L/L/K 18w AFF DUvu'r c ; DLVcf'p CE,ci:., f' : Co,ja.,,r roa CjvAOtoA-A^''R G~6A"~ A~~'~L AFF LlGN! I = baP(Ax dLt,,1 n,.,« fb" S_ I),,PLR„ i8 6b C E,L1;J s Z NEid CrAA~. OFG',ets s ;IXIA S/8 roc7,,c s i /►i S~p•- D~yw~I c. l- F~ L C r A,4 J, D r3 T C r 2 NGtt/ ~Af.I.S N75TiK STUAS s~d' DLI~WAL[. aAC AcG GG Ae-- .t , Wheat Ridge Fire Protection District Plans Aeview Date: 5- zce-m6 Reviewed by David M. RobertsJ7r&/L- Uniform Fire Code Certificatian #53215 Colorado State Fire Suppression System j Inspector Certification #92-173 ~Comments: ~k ~ c~s-~~~f~~`- • ~r✓/Z ~ ~r/'i ` r- y a -L 7615 Cv 38-"1 Av,6~,ltlfz- L.OAa /WO 4/ o„ ~ S-o ~ d g'-0 840 'i DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : 7615 WEST 38th AVE Contractor License No. : 18033 Company : Gordon Sign Co. Building Permit Number Date OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibMM or compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheaes, for work under this permit. (OWNER)(CONTR4CTOR) SIG NED DATE S< Cl ~ 10443 4/26/00 Phone: 9705931334 Phone : 629 6121 Construction Value : $6,000.00 Permit Fee : $125.25 Plan Review Fee : $0.00 Use Tax : $90.00 Use: Description : (2) Wall signs (1) South elevation (1) East elevation BUILDING DEPARTMENT USE ONLY SIC Approval: Zoning : Approval: ~?~~~~"Ilt Approval : Occupancy : Walls Electrical License No : Company : Expiration Date : Approval: Total: $215.25 Sq. Ft. : Roof : Stories : Residential Units : Plumbing License No : Mechanical License No : Company: Company: Expiration Date : Expiration Date : Approval: Approval: (1) This permit was issued in accortlance with the provisions set forth in yopur appliration and is subjec[ to the laws oFthe Sfate of Colorado and to the Zoning Regulations and Builtling Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixly (60) days fmm issue tlate or (B) the building authorized is suspended or abantloned for a penod of 120 days. (3) If this permi[ expires, a new pertnit may be acquired for a fee of one-half the amount normally required, provitletl no changes have been orwill be made in the original plans and specifcations antl any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceetls one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the naturel Flow of water causing a dreinage problem. (5) Contrector shall tWiBuItIldit Inspector hvenry-four (24) hours in advance For all inspedions and shall receive writlen approval on inspecfion card before proceeawif u softhejob. (6) 7he isa p rmgs and specifcations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the in f v , aw, Fule or regulation. c Chief Building Inspector r 0 0 i- ~ Ll~p Y S -71~~ Weathredqe # . . ./6i$ igp.$g L C886a9 dsVQia New 98" raceway mountpd channel fef:ers. Gption 2. Raceway peir,ted to rnatch PM8 482. Lstter returns painted to match Benjamin Moore lron Clad Brorrze Tone #963-60. z ~ ~ W 0 Qs z c~ ~ N N M ~ 0 n r- ti }C L¢u N N .i c .♦I ol I Color Key Ptrom fvr larger or: entationadpurpases }h,77i ShOWl1. 8ladroufkne I-BleckTrim Cqo T`- 2T ` and are not in scale antl may apFear Letter rebems pa7nted to match Berryamin Mnore (ron Gad Brortre Tone #163-60. W.,,• 1 iw J iSTOMER: Drawing Name: gp.plNN.61927.NA ilar CdtioNPrajec[: Designer 9a}hrlnqg em YFS te: Scale: AccourRRep: Sub 3735 Pe2chVe~~OM~-613Q80~1 Fax Tl4S130259 ~ 30360 MTM SIGN Letters ❑ 2037YeilowAcrylic S Loan Mart a ❑ 3M 3630-015 Yellow i 3M 3630-156Yivid Green - 3M 3630-22 Blaek @LCk -W~22 ~ CROSSSECTiON-Nf5 MxSM"M~ - B AWMIM1MftENHN g fl4CK ~ C PLFXF4C£ -0 p E GiPS 15MM5i11BNEON ESlWPOPT f GtASS FIOUSING O ~ 0 c ance,var H IS'JtNSFOflMEP I' - I J q5P".NJfEGTSWITGH VOLNnNG ND 0~lbE ~ I d# P FIEID W 9 Revisions: gmyeY_epxked added nil e.ft - CusNmer Approval: 222 ME9 MTM Approval[ _D E S I G f*I, I NC. Date: Date: O 2IX00 MTM & Assa:ia[es, Inc. lyis design remains our ProPertY and canrrot be duplicated wMhout written cronsenL I t„"I . I vj r ~ivi ruv%7 MIVU UCV CLlJY1YICIV I nuuaing rermrc rvumber : BUILDIN6 INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE ' WHEAT RIDGE, CO 80215 PropertyOwner: Lo,A„~ A•t} Property Address :-7 6 ~ S W. -7 qvQ • Phone : Contractor License No. : i frG 33 : ~ ~ C` • Phone :(3~y) 6 25 - 61 Z Company ~ ONMER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGRcEMENT I hereoy certify that the secback distances propased Ey lhis pertnit 2p0lic2L'an are accurace. and do not violate ap0licable ordinances. rules or regulations of the City of Wheat Ridge or covenancs. easements or resUictions ol record: Nat aII measurements shawn. and allegations made are accurate: lhat I have read and agree to ahide by all conditions pnnteC on Ihis application. anC Nat I assume tuii responsibilRy tor compliance with the Whmt Ridge Buiiding Code (U.B.C.) and all oNer applicable Wheat idge ordinanCes, for work unCer this pertnit (OWNER)(CON7RACTOR) SIGNED OATE~ -zi; Description : Z rs}c\ll (2) 511' w~11 s~ g~r c:- 5 ConsVuction Value : (eC)Qo , QQ Pertnit Fee : UseTax: nc 68 = Total : 31. >L L~7 et~~ ~':S'1 Q1a:J4~lo.•$ ~ BUILDlNG DEPARTMENT US ~ ~Pl~s L"Is(y cc& Approval: Zoning : PC.D ' ? ~ ;^~`J ~1ldlna~ ~l.l `c~C~l1CC~~.~ 4 . 2_ APProvai: Foblic:W_~tk3_Ca~i?h~er~s:? ~ - - ~ Approval: o j Occupancy : Walls : Roof : S;ories : Resid=nti2t Units : Electncal License No : Plumbing License No Mechznicai License No : Company: Company: Company: , Expiration Date : Expiration Date : Expiration Da,e : Approvai: Approval: Approval: ~ Pfans ftequfred'.:'J LM Pld'ns Required j Ppnsftb'qui(e'if._~ (i) Tnis cermn was iszuea in accoraance wnn tne Ore,n::ens set for,n m yopcr a :olcanon ar.c is suqea lo the laws cf tne S:a:e of Ccionda ana w the Zaning Regulanons an0 BuilEing CoEe o1 Nlheat R105e, Cclonoo or any oNer a;G,v-:e orCmu.ces of Ne Ctry. (2) This permrt Shall exprte d(A) the work autnonze0 is nCt CCmmenCeC wiNin SiaO/ (60) Oays h,:m i55ue Oate Or (B) V.e CuAEmg aulnonZeC is SuSpenEeC Of a wnoorea for a DencC of 120 Eays. (7) ❑tnis ee"rt ex0ires. a new pertnit may oe acCUireE kr a lee o( onrt+aif ine amcune nermaw reduired, provided no Uanyez nrie Deen or wdl De maCe m tne ori5inal Dlans ana spec+fica:ions ana any susoensicn or abanEOnment nas not ecceeEeE r•.e 11) yeac If chanqes are ma:e cr d suspenmon oraGanOOnment ezCeeCS One 11) yeat, lull lees 5halt be paiC face Mew Dermil (s) ho worK ol any manner snail Ee tlor.e U+at wili cnan5e Ine na:urai Aow of water wusing a ea:.1a9e DraOtem. (5) Con;rac:or snan noury the BuilOing Inspecmr twenry-feur (24) I+ours m aavance icr aii ms;r_cons anu snan recewe wnnen aoCrovai on mspecuon wrC Cefore prpCGGd,mq wtl0 SuCCCS9ve DhaSes ol Ne l00. I51 T`.c rssuance or a permd or me apCmval d arawmgs ana soeuGwuons snail r.ce oe conz:n:r. io be a Oermit tor. rsr ao al ol. any vi0lauon of Ne Dro°'sions DI tne ouddmg codes or any oNer arainance. law. ruie or regula:wn. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Gm///Voo- ~ ~ ~ ~ O 3o, 0 sAlad w A'~QrAleAovl ,DEPA}2TMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 9910 BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE Date : 12/14/99 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : 7615 W 38TH AVE, D109 D110 Phone : 422-2018 Contrector License No. : 18163 Company : Bighorn Signs, Inc. Phone : 420 7264 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : $2,240.00 I hereby certify that the setback distances proposed by this permit application are accurate, and tlo not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or PORTIIt F@2 : $83.25 covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this Plan Review Fee : $0.00 application, and that I assume full responsi ility for compliance with the Wheat Ridge Building Use Tax : $33.60 Code (U.B.C.) and all other applicable V1~ t Ridge fl i ances, for work under th' p (OWNER)(CONTRACTOR) SIGNE DAT Total : $116.85 Use: Description : Single face wall mount, internally illuminated sign metal & a crylic w/individual letters & logo on raceway 10'8" height 23 total sq ft BUILDING DEPARTMENT USE ONLY 91 Approval : MLC Zoning : PCD Approval: DM Approval : Occupancy : Walis SIC : Complies w/sign code and PCD regulations Okay, electrical to meet NEC Article 600 Sq. Ft. : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval: Plumbing License No : Company: Expiration Date : Approval: Mechanical License No : Company : Expiration Date : Approval: (1) This permit was issued in accordance with the provisions set forth in yopur applica6on antl is sub"ed to the laws of the State of Colorado and to the Zoning Regulations and Builtling Code of Wheat Ridge, Coloretlo or any other applicable ortlinances of t~e City. (2) This permit shall expire if (A) the work authorizetl is not commenced within sixty (60) tlays hom issue tlate or (B) the builtling authorized is suspentled or abandoned for a period of 120 days. (3) It [his permit expires, a new permit may be acquired for a Fee of one-haltthe amoun[ normally requiretl, provi0etl no changes have been or will be made in the on9inal plans antl specifications and any suspension or abandonment has not exceeded one (i) year. If changes are made or it suspension or abantlonment exceetls one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be tlone that will change the naturel flow of water causing a drainage pmblem. (5) Contrector shall notify the Building Inspector hventy-tour (24) hours in atlvance for all inspecUOns antl shall receive written approval on inspection card before proceetliing with successive phases of the job. ~6~ of th~'ssua f a p~the approval of tlrawings antl sPecifwtions shall not be construed to be a permit for, nor an approval ot, any violation of the provisions E,bt' in other ortlinance, law, rule or regulation. Chief Building In ector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BIJ.ILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 APPLICATIo N PropertyOwner: Fiu6 lF-1D irISURAN(,-E Property Address ~ ci v3 3s 7u Phone : 3-)3 i~ Contractor l.icense No. Ic7s Company :-BI GqC'f~.tf S 16 n1 S, i N r_ Phone :,~63 t17o 7 Z.G L~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : I hereby certify that the setback distanees proposed by this pertnit application are accurate, PefRlit FBB : and do not violate applicable ordinances, rules or regulations of the City of Wheat Ritlge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this US@ T8X : appliwtion, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ardinances, for work under this permit. Total : (OWNER)(CONTRACTOR) SIGNED ~GLfiMCS DATE Q US@ : 571Jc,~~ ~~~t- aJ4,1-L I~uun/; I N,C''r-_J Description: ~N~JIV'Dt-F- TT~~+':'3' Fr. 10'2" IVL16rIT 23 56 BUILDING DEPARTMENT USE ONLY ~~y N-t~Ap~cs ApProvai : n,A-C- V C-b ~lSLC,~S~ 8 Zoning : Q C / u ~ ~A ~4. 4~ ~.-,ut .✓e~ A~e.le..6.Ua r~ Approval: 1;4~ Gm'"~ N Approval : Occupancy : Walls License Expiration Date : Approval : Roof Plumbing License No : Company : Expiration Date : Approval: A, ;yU?yrk '"ll ~-~,l 1-, ~ Ild C1.10 Rfi Ft. : Stories : +~g~ide~6~(l~ifs : Mechanical License No : Company : Expiration Date : Approval : (1) This permit was issuetl in accortlance vnth the provisions set foM in yopur application and is subject to the laws of the State of Colo2tlo antl ro the Zoning Regulations and BuilOing CoOe o(1Nheat RiEqe. Coloratlo or any ot~er applicable ordinances of Me Ciry. (2) This permit shall e!~pire if (A) Me work auMOrixetl is not commencetl wiNin siaty (80) tlays from issue tlate ar (B) Ne builtling authonzcd is suspenAetl or abantloneC for a penoC of t20 Oays. (3) If this pertnit expires, a new pertnit may be acquiretl for a fee of one-half Me amount normally required, provided no thanges have been or will be me0e in the onginal plans antl specifications anO any suspension or abantlonment has not exceetletl ane (1) year. If changes are matle or if suspension or abantlonment exceetls one (1) year, full fees shall be paitl for a new pertnit. (4) No vrork of any manner s~all De tlone Mat will change Me natural flow of water causing a tlreinage problem. (5) Contractor s~all noUy the Building Inspector twenN-rour (24) ~ours in advance for all inspections and snall receive wntlen appmval an inspection cartl before proceetliing with successive phases of Ne job. (6) of ihe i The issu of a permit or Me approval o( drovrin05 and specifiqGOns shall not De wnsWed lo be a permd for, nor an approval ot any violation o( Me pmvieions tl g co r any other ortlinana, law, rule or regulatlon. Chief Bu' ' g Inspector 00 ~ O ~ , 2v VV ~U 1 ~ ~ E o Fl\\\~) ~ 5 SS 0 ng. .d O `J P'j ~ J I~-1 •n+ o .n ~S o 5"~d F= n 'r'~ ~ O :1 a y n ' cc`~ to ~ ~ (on 0 ~ o0 n' ^o\ n \UJ ~ - Cl ~ ~ li VU co ~ ~ 00 ~ ~ V ff3 / \ \ r~g U im ~ ~ (7 4R- - _ ~ ( 00 IWO ~),AyL i ~ (P~l 0 ~ O O ~ u G I O ~ C ~ N ~ ~ ~b ry n ~ "1 ~ ;~:~9u1 \l~/ O oo N (D y LL ry O ~ j1 6ci~ + ~n C O P~ ~ ~ ~ 0 ti%~, (~'~O ~ J N P '1 ~ N 7 ~ ~~;r~ ~ O b 'n ' y ~ 'p ~ ~ N R b O ~f ^ p n Q x n 4 a~i o ~ o Fi O'm C G O ~ y e i I- ~ ~ z w ~ ~ i ~ ~ I I II ~ `Y% u 1-:> (N (DD ~ ,n~, n~ G4~ ~ o v 00 - ~ ov ~ ~ VU 00 ~ ~0 \/J~ U ~ 0n10 V ~ C::~ ~o ff)o 1~,AAINMK3 D: DEVEIAPAIIENT Building Permit Number : 2641 C► ~V~It'~i - 936 2855 041%1 RID13E Dafe : 2l15l96 ,T#1@91~87"`'~'F~ AYEhI1JE' I~iIWEAT #tOCi4 CO 80215 PropeRy Owner : V1AI,ItORE GENTER ING Property Rd+dres8 : 7915 ' 38TH AV ContratW Limsse Na. : 17340 CompOrtY : 5a1Chs LawbNAttCraft SigNFrorrtage Sign O1rtlNfRACt)M°I`RAC7f5f2 SIQNATURE OF lN0ER3TANDIiJCi AND A(3REEMENT r r*re6y, tl~~ anr aiwi~ popwr andda~~wr~ u4timpa,~oee 'Nddls ~ ;1 eM~wM ~a 04 'b (OVMlaRxC(SNT~'01~ BKiNED L3bscPiptkul: tN8Fl4Ll 1 SEl' OF 1) ARE 2' X2S.51=5i.76, Phone : Phone : 777-7771 . ConsUvcticn Value ; $900.00 PernitFed : $75.00 Plan Review Fee : $0.00 Use Tax : $13.50 Total • 328.50 -vn i c - C..,.= AN GHANNELIESTTERSMQUNTEDTORACEWAY. LETTERS EPARTMENF U5E ONLY SM'02M5/88 PCP T_brfifig : Roof : 9tories : Residentlal UniFs : No: Dn Date : Expiraticn Date: Approval : eteoimnyopur .rIO sub]W ain.araa w.em.atxbrwosne1am.za*q ~~~fiam W W~tlps or (6)1M WIdYp.sMafaWk swpMqetl ar rooi,'onslnMBM wrbuMnprtrAYropukW, p~y~p ,wd~rpNMvebea~orVMlOsmsft intlis ~ . m~damm0 M ntSnotaa~deaone(1)Yw. Ncfwrq~sYSmsdsaYNqpemMnaahtlidoinwR.. I~tlbwdweNr s.. aqrNnpspiodNm:. 4lhoursNladYblOelaM nONW~x7XbnMxovalal:MqpsttlonafGEpPo1s =014 staN nM be awwN+ed m hs e Pm* far, aa en oPPmvd a4 wW vkNYw W ths povMbrro iK314ED 8Y'tNE CHIEF BUI@bMIG M l:At.k:C 2%f ~ DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : ~-/S-qCQ Property Owner : 6_.sRG}T GG6025 ?ZA~Nii1/G PropertyAddress: 74/5 OJ. 39t $_129 ContrectorLicenseNo.: 173y(I Company : $,1<:f/-5 ~~,r0✓~~j~j27~iA GExIT~,2 Phone: $9(~+1/ Phone: -7-7-7_77-71 OWNER/CONTR.4CTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or wvenan[s, easements or resMctions of rewM; that all measurements shown, and allega[ions made are accurate; that 1 have read and agree to abide by all wnditions printed on this application, and that t assume full responsibility for compliance with the Wheat Ridge Building Code (LLB.C.) and all other applicable Whf31 Rl$ge or an , for work under this permrt. C (OWNER)(CONTRACTOR) SIGNED DATE .2-~ G. Description : ii atr ar- : zs. s - _ _rr, io so gafr _V,51~7 BUILDING DEPARTMENT USE ONLY Approvai : 6vlet,_ Zoning : Pu' Approval: fq~M!Sy:.!!yO.CA~Y~L1~l~9~ ~YDy Approval : Occupancy : Walls : Roof : Stories .yowrzw ToAW'qy Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company Company: Company: Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : j Ptans RBquteedv,,;-:; 1 3 R11(hs Requlred I gi kmp#'m u_l .,W . (1) This permit was issuetl in accordance with the provisions set fortn in yopur app6cation and is subject to the laws of the SWte af ColoreEO and lo Me Zoning Regulations and BuilCing Cotle of Wheat Ritlge, Coloratlo or any other aDP~icaDIe ortlinances of the Ciry. (2) This permit shall explre if (A) Ihe work authonzed is not commencetl within sixry (60) days from Issue tlate or (B) the building auttionze0 is suspentletl or ahantlone0 Por a penotl of 120 days. (3) If this permrt ezpires, a new permit may Oe acquiretl for a fee of one-half [he amount nortnalty required, provltletl no changes have been or will be matle in the original plans and specificatlons and any suspension or abantlonment has not exceetled one (1) year. It changes are matle or H suspension or aDantlonment exceetl5 one (1) yeac full fees Shall be paitl for a new pertnit. (4) No work of any manner shall Ce done that wiil change Me naWral flow ot water causing a tlrainage problem. (5) Contraaor snall notdy the Builtling Inspector tweny-four (24) nours in atlvance (or all inspections and shall receive wntten approval on mspeclion cartl De/ore proceetliinq with 5ucces5ive pha5es o( the Iab. (6) 7he issuance ot a permit or the approval of drawings and specl(wtions snall not be consWetl to be a permit for, nor an approval of, any vialation of the provisions of the Duiltling wtles or any other ortlinance, law, rule or regulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Construction Value : g` -r'Q7•0 Permit Fee : • Use Tax: TOtal : z 0 , d 0 ~ x U-1 ~r N ~ L ~ ~ 2 0 : 4 t A IIl yb - Y L-Y3d 8 i i> a. c 4 T r Q YL4 ~ • ~ I I III~ I~ I z ~ I ~ ~ s I m • ~ I ~ i ~ ~ N VJ y 5 I ~I I ~i III II I I III I~ lil ~ I~II i~ill~ II ~ . m ~ II I ~ o ' I II I ~ a ,esavsun~ n. di~ ag~66~~~°~ Z A ~ T C v ~ £ A ~ ~ st~~zs .~~t~al adHDs wd~s:se ~5, Y ~ Y~~ • SACNS~~OM „ . t~; ~ ,u~... O"WWOiL TELEPHONE: (303) 234-5900 The City ol 7500 WEST29TH AVENUE • WHEAT RIDGE, COLORAD080215 GWheat 9Ridge TO WHOM IT MAY CONCERN FROM: JOHN W. ECKERT DATE: JANUARY 10, 1996 SUBJECT: JOB COMPLETION This is to confirm that all inspections have been done on the remodel of 7615 W. 38th Avenue, B129 for the Great Clips space and the Building Code requirements have been met. A copy of the inspections perfonned is attached. If there are any questions, please feel free to call me at 235- 2853. att. /at Building Permit Number: 2275 Job Address: 7675 38TH AV B129 ~ Description of Permit : INTERIOR REMODEL-NEW WALLS Inspection List Number Type Date A roval Remarks 4018 GROUND IRON, RP & WAtER PIPE 12/5/95 OK/JE 4027 FRAME-KEY OVER DOOR 12/5/95 OK/JE 4094 DW SCREW KEY OVER DOOR 12/11/95 OK/BG 4367 FF 1/5/96 DIS/JE GRAB BARS MISSING IN BATH 7SINK IN FRONT 4394 F HVAC 119/96 OKIJE 4395 FE 1/9/96 OK/JE 4396 FF 119/96 OK/JE E: INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE I N S P E C T I O N R E C O R D(303) 234-5933 IOBADDRESS_ 7615 W. 38th Avenue B129 BUILDING PERMIT N0. ~ 95-2275 DATE ISSUED 111 21195 TYPE occuvnNCv OWNER Wi.lmore Center, Inc_ CONTRACTOR The Craftsmen SETBACKS fROM PROPERTY LINES: NORTH SOUTH EAST West INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB INSPECTION DATE INSPECTOR Foundations Footin s Caissons Reinforcin or Monolithic Weather roofin POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor: Electrical Ground Work 11 el ~ Plumbin Ground Work 1 /j e-t- ej . Heatin Ground Work DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED Rou h Electrical S Rou h Plumbin /Z 's s1 AirTest Gas Pi in Rou h Heatin & Ventilation (above must be signed prior to lraming inspectionjl Framin Insulation Dr wall nailin l3 < S 13, 61- Roofing Refri eration Electrical under round Final Electrical Fixtures 1.4 Plumbin Fixtures Heatin & Ventilation Landsca e 8 Parkin R.O.W. 8 Draina e Fire De artment Job Com leted / OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED DRr1T9:('T TFaIC ('_AR11 F12[1M THF WFOTHFR T Building Date :12/21/95 80215 i 7615 38TH AV 8129 ; 17087 Good News Heatlng 8 Air CondiGoning OF UNDERSTANDING AND AGREEMENT xwrk Phone : Phone : 934 2477 Construction Value : S7.5Wuu Permit Fee : $35i:00 Plan Review Fee : $0.00 Use Tax : $22.50 Total : 557.50 '2 ~ 5 F -jEXISTING LAY IN DIFFU3ERS AND DRYER VENT , d BUtLDIMG DEPARTMENT USE ONLY F ~ ~ ~l ~ + v . ~ 1 r „ x WgIlis : Roof : Stories : Resideptial Units : Plumbing License No : Mechaoicei License No : A. Company: Company: 4 Expiration Date : ExpiraGon Date : ' r Approval : Approval : ~ 444 10 h vA)JW wmsmwaof u,ssmsacawradoanaa+esza+uw aM sK rornhM yoaur avqiauo1 . . aan«arn~ ua~ea c~y~ d a~oAsed ro supNM~d or . x mnreaneetl ww~~ineodsYS xom iesue date a(B) tl~e buAYq uaroeamWnanmemaumnOMIWH11W1red,~ ~~obBt waWnaonnem haa not axceedea ona (1) vear• . PKMIL the awW nw cwslrtg aamhw.wvbWm r „,r (zq nowa In.evanoe ror aa" ana enali r.oNw wrMm wvcvlm 00 kNp°I c4rd:13efa. ana eveoftatio^s anail na ee can.wea m ne a pemin W. nor.n+vpmvW a, anr Adabo^aM°:pm'b"° e a repWMlon. . . ONLY WHEN SIGNED BY THE CHIEF BUN.DIN(i INSPECTOR 2344933 24NOURS PkIOR TO INSPECTION 90 ~f DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : , Z' Z \ I I ,S Property Owner : 60 tJ ti &A Property Address :-7 41 ~ w 3 gN 2 1-4q Phone : Contractor License No. : 11 p g"'' Company: G000 OL-^A tifATt1ilk/~ ~ Pnone: 4 -7 1 OWNERlCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiy that the setback tlistances propose0 by this pertnit apptiwtion are accurate, and do not violate applicable ordinances, rules or regulatians of the City of Wheat Ridge or covanants, easements or restnctions of recortl: that all measurements shown, and allegaBOns ma0e are accurete: that 1 have read antl agree to abide by all conditions printed on this application, and that I assume full responsibility for compllance with the Wheat Ridge Builtling Cotle (U.B.C.) andall other applicable W at Ridge ordinances, for work under this permR. (OWNER)(CONTRACTOR) SIGNED C1/_DATE~ T~ Description : (Z-e-(A Approval : ENT U Occupancy : Walls : Roof : Stories k Residential Units : Electncal License No Plumbmg License No : Mechanical License No : Company . Expiration Date : Approval : J PfBnsAaquired....l Company : Expiration Date : Approval : _3 PIBns Required J Construction Value 5'0~ o Permit Fee : Use Tax : Total : Y Company Expiration Date : Approval : I . mft,ggt (1) This permrt was issuetl in accortlance wnh the Orovisions set fonn in yopur apphcation and is subject to the laws of the State of Coloratlo and to ihe Zoning Regulabons and 8uiiaing Cotle at VMeat RiEge, Coloraao or any other appllrable ordmances of the Ciry. (Z) tlonetl for aa penotl of 120 h ~e ~~rk authonzed is not commencetl within sixry (60) days from issue Eate or (B) the bwl0ing authonzetl is suspentletl or aban (3) If this permtl expires, a new pertnit may be acqmretl for a fee of one-half the amount normaily reQUlreQ prov14e0 no chan9e5 have been or will be matle in the original plans antl speGfiW6ons and any suspension or abantlonment has not exceede0 one (1) year. If changes are matle or if suspension or abantlonment eaceetls one (t ) year, full fEES shall be paitl for a new permR. (4) No work of any manner snall be aone tnat wJl change ihe naNral now of water causing a tlranage problem. (5) Con(recmr shail notiry the Builtling Inspecror twenry-four (24) hours m aavance tar all inspecuons and shall recerve written approval on mspeclion cartl before pmceetlimq wrth successrve pnases of ihe lob. (6) 7he issuance of a permrt or the approval ot tlrawings and speafiwtions shall not oe construea to Ee a permit for. nor an appmvai of. any violation of the provisions of the bwltling codes or any otner ommance . iaw, mle or re9ulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CAIL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : C/i//C I ~ i~ P r.,✓P Property Address Phone : Contractor License No. : Company " Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback tlistances proposed by ihis pertnit application are accurete, and do not violate appliwble ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restnctions of recortl: that all measurements shown. and allegafions made are accureta: that 1 have read and agree to abide by all wnditions pnnted on this application, and that 1 assume full responsibdrty for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinan 4, for work untler this pertnt. (OWNER)(CONTRACTOR) SIGNED ~DATE Descriotion : 17/ Construction Value : j 3 Od Permit Fee : Use Tax : Total : BUILDING DEPARTMENT USE ONLY Approval : Zoning : Approval : R9k,li~'~!NENC + Approval : Occupancy Walls : Roof : Stories : Residential Units : Electncal License No : Plumbing License No Mechanical License No : Company Expiration Date : Approval : _j Ptans;Raqulred Company : Expiration Date : Approval : _3 Bllins Required I Company : Expiration Date : Approval : I : F-Pttl (1) This permrt was issued in accortlance wnh the provisions set fotlh in yopur appi¢abon antl is subject to the laws of the State of Coloratlo antl ro Ine Zomng Reguiations antl Builtlin9 Cotle of Wheat Ritlge, Coloretlo or any other apphwDie ortlinances of the Cify. (2) This pelmR Shall expire d(A) the work authOnzed is not commenceC within Sixry (60) days hom i55ue tlale or (B) the builtling aUlhonietl is SuSpentlEO Of abantlone0 for a DanoA of 120 tlay5. (3) If this permrt enpires. a new permR may be acquired /or a fee of one-half the amount nortnauy requireQ provitle0 no changes bave been or wdl Oe matle in the original plans anC speufications and any suspension or abantlonment has not exceedM one (1) year. If changes are matle or if suspension or aban0onment esceetls one (1) year. full fees shall Ce paiE tor a new permit. (4) No work of any manner shall be tlone that wtll change tfte naWral flow of water Causing a tlraanage problem. (5) Ccniractor snall noby the BuilOing Inspector twenry-tour (24) hours m atlvance ror all msDecuons and snall recerve written approval on mspecbon rarA before omceeaiing with successrve phases of Ne job. (fi) The issuanCe of a oermit or ihe approval of tlrawings antl speci(IWtions shall not be conSiNea to be a OertnR tor. nor an approval of. any violalion of the provisions of Ne butltlmg COtles or any other ortlinance, law, rule or regulatlon. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Building Pertnit Number : 95-2335 Date :12/4/!85 WHEA'f RIDt3E, CO `80216 Property Owner : WILMORE CENTER INC Properly Address : 7815 38TH AV PFwhe : 922-8956 Contrector License No. : 18852 Company : D.G.S. Electric 5ervioe Phone : 7610630 ONMER/CONTR/1CTOR SIGNATURf OF UIdDERSTANQiNG AND AGREEMENT cowNewteorrrRa,croR> si ~'~t-Lwejr~ Descxiption : TENANT FINtSH ELEC-INST14LL UGHTS B-129 . ApPravsl: Zoning : , pPProval : ConetruCti011 Velue : $3.100.00 Pertnk Fee : $89.00 PNarr Revisw Fee : $0.00 Use Tex i S46.50 Totat: $115.50 ' fS AND SVINTCHES FOR GREAT CLIPS, Mt7VE CEIUNG BUILDING DEPAFtTMENT U5E ONLY Approval : Occupancy : Walls : Roof : Stories : Residentlal Unids : EtecMcal Lk:ense No : Plumbing Liaense No : Mechanical Licenee NO : Company;: Company : Company : Ettpiratlon Date : Expiratlon Date : Expiration Date : APProvaL: Approval : Approval : t~) mu wasi..~edmao~o~wnne~.v~w~n«eram~nropr ana~.w.aam.'p~waatn.sa►.acaorada.nammsza+~q .no~o cod. wvxw+~t cdor«do «mr anr auor ~ cpy. obgdy (2) ~.~r«prowµm.WOacMw~°:aroa«im,bnc.ewha.r.nomreu.a.a«(8)m.nwm~wum,awauwWsnasa« fa e pNWd at i (3) H9M! o. e MW ~111~' W 1~W fOf a iM of dMINMtlM M104M IIp~IYMY ~~sd.O~WIdBd n0 dlilptit hqtE6011awMl b671iC~k~ YMpf{ 8n0~M~danpfu~oen M~entlO~MmrltharotoicwEeAOns(1)Y~. Neherqamam~aMw~id+a~aCpntlonr~R am . eWs dls (1) Yar. NRA1M oM$ hr pMd 1ar a n~w tb otanYrtYMMnerMNIEO.d~le&WtWdurgeMa.n~GrtallbwdwaUrp~~yq e@+NepsDrobMm. (61 ~*N~ft*#W ~~~pp~b~hiR (Z~) howa M WwnOe fp e@ fnepectlom uM tlbll taoeXrtwhtlmn ppprOW an prpsWan ~ hMr! . (e) orpermx « l0wKpaKo ~nww o~(.~ ~ roepp~~onns awk na tie cauww ro ee.parmx ra, ~.n oppma W..any Nwstla, oruN pmW.bn. l\L~e~. , ~/d L,. A.. ' . . . . ~qET t3U1W N191n$PBCIOF . . . (J THI$ PEFt111tT VALW ONLY YYFf!?N SlfiNED BY THE CHIEF BUN.ENM445 INSPECTOR CAIL: 2344933 24 HOUIt$ PRIOR t4 fN8PEGt10N ~33 S DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date :l " f-- ~ Property Owner : Property Address Phone : Contractor License No. Company : ~ ~%r Phone OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Constfuction Value : j/(6 O I herehy certiy that the setback distances proposed by this permd appliwtion are accurete, P@fRlli FQ@ : and do not vlolate appliwble ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: lhat all measurements shown. and allegatlons made are accu2te; that 1 have read and agree to abide by all conditions printed on this US@ T8X : application, and Nat 1 assume full responsibility for comptiance with the Wheat Ridge Building Code (U.B.C.) and all other applieable W t Ridge ordina for wo under this permd. i T0t21 : (OWNER)(CONTR4CTOR) SI NED ~~sw~ t DATE Description : BUILDING DEPARTMENT USE ONLY Approval Zonin 9 Approval: Approval Occupancy : Walis : Roof : Stories : Residential Units : Electrical License No : Plumbing License No cd~ i".n, e-eompany : Expiration Date : Approval : J , Ptans Raqa(red :l Expiration Date : Approval: j PIAhs Required I Mechanical License No : Company : Expiration Date : Approval : -1 LEnL291400 1 (1) This permrt was issuetl in accorEance with ihe pmvisions set torth in yopur appiication and is sublW to the laws of the Stale ot Coloratlo and to ihe Zoning Regulabons and Buildmg Cotle ot Wheat Ridge, Coloretlo or any other apphcable ortlinances of the Ciry. (p) This permit shall expire if (A) the work authonzed is not wmmencetl wrthin sixry (60) days fmm issue tlate or (B) the bwldin9 authonzetl is suspentled or aban0onetl br a periotl of 120 days. (3) If this pemmt ezpires, a new pertnlt may be acquired for a fee of one-half the amount normalW required, provitletl no changes have been or will Ce maEe in the onginal plans and specifiwlions and any suspension or abantlonment has not exceedetl one (1) year. If changes are matle or if suspenswn or abantlonment exceetls one (1) year, full tees shall be paitl for a new permit. (4) No work of any manner shall be tlone that wtll chan9e the naNral flow of water tausing a Orainage problem. . (5) Contracror snatl noUry the BuilOing Inspector Iwenry-four (24) hours m atlvance for ail inspecuons ana snall recerve wntten approval on inspection cara before pmceetliing wrth suaessive phases of the job. (6) The issuance of a permrt or the appmval of drawings and specifications snall not oe mnstruea to be a permrt ror, nor an approval of. any viola4on of the provisions af the butlaing wtles or any other ordinance. law, rule or re9ulation. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CAIL: 234-5933 24 HOURS PRIOR TO INSPECTION ~ NT pF ,Pl,ANNING AND DEVELOF~IIfENT Building Permit Number: 95-2275 ~ ~F7WH~T RID6E - 235-2853 Ciate :11/21/95 ' 7l500WEST 29TH AVEWUE : WHEATRIDGE, CO $0275 properly Owner; WILMORE CENTER INC pro'perty Pddress : 7615 38TH AV 6129 Phone : 768-1000 fttr&~ License No. : 18639 Company : The Craftsmen phone : 9728952 31GNATURE OF UNDERSTANDfIJG AND AGREEMENT ~.tro~Q..C:(/~ l11~RACTOi~ 316NED INTERtOR REMODEL-NEW WALLS BUILDING DEF i . N USE ONLY ConBVuCtlw Value : $4,331.00 Permit Fee : ` $72.00 Plan Revlew Fee : $0:00 Wse T2x : $64.87 Totai: b136:97 DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 onS k~n c'!86$ ~~*~^'w~ao A2~~~ P~2«c~~,-z1` Properiy Owner : C Property Address : ''1 1~t ~ W ~ 18~ A~YC ~ Phone : 766 Contractor License No. : 9 I Z-CA S z-- 02 Company: -F4.V Gicp~FT-sN,EJ Phone:32289 pHr.j.~• Y6t'7z~z OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMEN I hereby certity that the setbadc distances proposed by this permit application are accurete, and do not violate applicable ordinanees, rutes or regulations of the City of Wheat Ridge or covenants, easements or resVictions of rccortl: that all measurements shown. and allegations made are accurate; that I hava read and agree to abide by all conditions printed on this applicalion, and that I assume tull responsibility for wmpliance with the Wheat Ridge Buildin Coda (U.B.C.) and all other applieable Wheat Ridge ordi ances, for work under this permrt. SGNED~ ~DATE~ T Construction Value : Pertnit Fee : Use Tax : 9 J Total: (OWNER)(CONTRACTOR) I ~.L. Description: 1 0~_vJ in(-A'(1G1 £i,,£cT'a-• tflL PW BUILDING DEPARTMENT USE ONLY ~ Approval : Zoning : Approval : Approval: Occupancy : Walls Roof : Stories : Residential Units : Electrical License No : Plumbing License No Mechanical License No : Company : Expiration Date : Approval : Pfans.R%n(reO~;y. Company : Expiration Date : Approval : J PIiftUS Required Company: Expiration Date : Approval: A S A~A*-1~ (1) This pertnR was rssuetl in accortlance with ihe prowsions set forth in yopur appiicabon and is subject to the laws of the State of Coloratlo antl to Ihe Zonmg Regulations antl Builtling Cotle of Wheat RiCge. Coloraao or any other applirable ordinances of the Cily. (p) This permrt shall azDire iF (A) Ihe work authonze0 is not commencetl wilhin slxry (60) Aays hom Issue Oate or (B) the bmlding authonzetl is 5uspentleO of abandonetl fir a penoE of 120 days. (3) If this pertnlt expires, a new permit may be acquire0 for a fee of one-half the amount normally requtreQ provideG no changes hava been or will Ee matle in Ihe onginal plans antl SpeGfications antl any suspension or a0antlonment has not exceedetl one (11 year. If chan9e5 are matle or if suspensian or abantlonment ezceeES one (1) year, full fees shall be paitl for a new permrt. (a) No work of any manner shall be done that wdl change the natural now of water causing a tlrainage pro0lem. (5) Contractor snall noBy the Builtling Inspector twenry-four (24) hours in advance for all inspecuons and shall receive written aOProval on inspecuon car0 DePore pro m,e ing with successive phases of the Iob. (6) Thance~6f a permit or the approval of drawings and specifications shall not oe construea to be a pertnit Por. nor an approval of, any violation of the provisions cotles or any other,9fiJinance. . law. rule of regulation. oS lltli~g ief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION x~i ov+T 3~.,-~Dr 2 A ~ m O A ~ ~ O OD\\~ ~~rna ~N r NW ~D V 0) Q 7 ~ C~ N O ~ H -j C) ~m L~ VV > * z ~ z T~ m m ~ N = m z n X ~ ~ N Y C) ~ ~ O ~ n r 0 O V z mn P ) i ~ N < Z mc Nm z a i m ^m D x ~ e: N N' N I i U 00 tl J V P ~ x n~s N ~ i~ n z n H~ f"I yX o A r N / ~ I 0 m I o 0 r N N i ~ ( ,F- ^~NW~ C) 1> W ~ A ~ n ~ o m W O O ti ~ to Vl N O 00 m~ °Z 0°Z =n N cn -r Ln m A fTl W m ~ ~ Z ~ o m i T 0 p A I m i „t ~o I T m m nl~ I 'I^ ~ olo D S pi in0m ~ r=m?< - n° ` W r,l. Al 1z'-e '/z. ~ ~ ° u ~ vi~ (,t+I~ ov ~AZfc~ ~ cn o~F m> > rS c~m D," F J ' II Z-c z' ~ Ac>✓` Ll ~ TN R' A ~J p \ m C ~ ~ n x v . r' ~ )~1,~~~~ II A °T A ➢ I I ~ ~ A -~g_o m fn ti - - - ~b ~ < < ^ \ 1 ro-+ J ~ OmA C ~ \n F L 7"c\o ~ ~T3 ~2 / Z a ~~rnm 1 A II o0 11. ~ m f T Z D~ ,'w~~ II zn ~NC'mn fa y~ ~ ~ C.Z ~ II C~ i >ZAZO \IV 1 00 DZ Z mDD4lZ, Z T. t~ R Z~ mo ~I y ` ~ Am ~ z z E Z S j~ S ! rn II ~t-~\C 0 9 NOGI O~ S~yN I u f ~ u F ~`J tT j LA ~A z- z,0m O I~ ~ ~ FLLN ~0 fi O ~sF' H ~ Dc~h=~ ~ i~ ~ S h A 0 f D~r y 7~. O `~"O \ t+ a O ~ 12'-5 7 7 N C N ~ I^ o m➢ m ~ N C r C A1 6 II Z O ~ Go ~O A ° m < = m D ~ W z ~ O I X O 5 r ~3~ --f Li T I ` ~ . N (~A 1^ ~ o ~ L ~ f n cn o= m~ D ~ m r n _1r Jc o z°~ov~ $ ~ m m n \ O S D z 0 Zmmz '~mmm ~Fk.-~O m ~+i 'm O Z `zmi my o ~ 0 ~C)O~Au ho mv~ 7 m m< o m ` 1• ~ = D ~ Z L ~ ~Z A D G1 r~ ~ m D~ r G Z nmyo~~ x'~vZm~ n DZU~~z~i nvr.,r1 ~ - ~ D Ln ~ U1 r~ ~o< ;D n x p I O Z O v U n . . C) m D C m r Z O p~^ n ~ 0- 0 W 15 v~ I ~ 22'-10 I/8" I :Il O m N m to m{n~m nvnc z o z o u~ -t rp N ~W ~ S D C ' A -i = ?~y Y D m~ N ti r ~ N f1 -iN-p J~ Z N O op ~Ld H w ~ Z inCramX- ~m ~'1 ~LOrm°- Z 0m 7 OY~=N n y 0 ~ m ~l N~ N Z D Z mreA O ,Z0 m~i ~ no o~ m £~n V ~n N C%om _o M m~0_ MD ~ o.'c N A z ~ M ~ -c D fi T T 2 1~ M1 Ro ~ N A r n ➢ n s~ S Z A mp r m Q 0 T i' ~ (Tl ~ ~l O ~ ~ m m m ~ X IT7 ✓1 Z m x ' p m = o n Z Z Q c~ O -Ci x O m ~ X C Z -i F, (l ~ O N C Z O i N -i m G 2 ~ r ~ A D 3 Z 0 Uyi;SEF~'~~~9 ~ma>m ' 0 ~ >a~~Z - :0 N 00 /-1 ;D~ SJJ N ~ z tA O ~ J u ~m ~ C L m}~ 1~~ .J J ~ Z ~ ~ rTi Z rn m G f!~ ^O x tP -Ni: O N ~Q; Q' ~ ~ D ~ r ~ R ~ q : ~ o. O w i 1 r Y r 9 z ~ r=C = T D T C A 0 n ~ A N Z z mn ;o m ui n ro o ro r z A :U N 0 v' z n ~ r m 0 ~s ~ N n~ T 4 ~ h' en Y ~ w ~ 4 N i Ip %O V i t ♦i i ~ i0 v y P gp,cl r \~r O~• < I K v ~ n o ~ ~ Z 0 -Nd ~ D ~ m f 1 ~ M ~i' ~ `W y~^oL ~N .._tx' 'n O~A~r ►~1 ~ n i c> f >~"~mn OGn nA mrn i^D~ tOmmE Z .f mo ~ m z ~Y i z~ m G7 vR°-Ci"n C+r~ m2z ` ~ ~ ~ N Q 1r N n n i,n ~'Ym s ti ~ C nm m. rti~' c r. ^ ~za p D Z . i ~ y j~ 0 1z ~ r S'"~ m C 1 ~C, j z a f~ i~ -~I ~ . m y rz ~ ~ t> v a~ ~rp rn V~~ N ~ ^'LNW~ ~ V o ~ c~ G ppDa, n yy v op. m_ C m~ F ~ zuiz✓i y K✓~ > r>~ VmmCy c ~ ~ y C^_~~m Ci yD L QfqA..rC ~ m S~o C)mj C~ N LD ~ Q m (7 oN Wp ' O ~ tAfs ~ ~ 3?K z ~ r l17 N L a n r°,1 ry Z y p P. UI £ ~%n Z (.n O i' ~ JC ?7 ~ i ` r~n c0 - O 7c0 m pi(~ I~ N n m 2\ ~ ~ ` C d I ~ I . ' ' ~ I l~2 : ( /Y f oZ : • ~ . ~ir N ~ . , ~ ~ _ . a i ~D I t ~ 1 I ~ i I ' n c+ ; - . ~ ~ I ~ \ ~ \ ~r- ~ • 1 i I i I ~ I • ^ DEPARTMENT OF GOMMUNITY DEVELOPMENT 7500wE5729thAVENUE BUILDING INSPECTION DIVISION PERMIT N0. M93#19098 234-5933 P.O. BOX63e CITY OF WHEAT RIDGE, COLO. THIS PERMIT VAUD ONLY WHEN SIGNED BY TME CHVEF BUILDING MSPECTOR ANC RECEIPTED BELOW. ~ APPLICATIO~ FOR MISCELLANEOUS P~RMIT ~ ~7/Ir IA/~ ?SYTW, iu~arP, n,c. _ .4nC~ IdA) u/C/170, /7it/ IOBADDRESS ~ TOR A 1~ V v I~~- - FPOIZD/1OL SIG-NS INC ~vvncn • STEF_1 g~-: ST.DEA1vli~J O- ADDRESS :ONTRAC tJ ;F 4DDRESS 29 36 S 7U I , PHONE ~1-56 -085D ZIP CODE ~ CITY /O ~N('rL~'W~~~ i ZIP CODE 90//0 `7f~1-~1-323 LICENSENO CONTRACT PRICE $ ~Z g~ °o DATE IZ-IS- I :S. - . PHONE TVPE Ground ❑ 1 M~a Proiectinp❑ 0fhe, S a D Feee SIGNS . 2. MATERIAL STEEL r~.,asT,r 9 ~i • Total Squon Fe~t z~_ ys I~S77G ~hT1Kf per f No 3 S J~ ILLUMINATION Y ~ N ❑ T _ . . o n yD 7 od, 4. SET BACK FROM PROPERTY LINE N_ 5_ E_ W Zons ~ les dw (Specily which ie fronl l ❑ ❑ ❑ 1-1 Diwpprovad lZ-t(I I. TYPE Solid[:] More Than 80% ODenO Less Than BO% Open MATERIAL . Heiphf ? FENCES . 3 SET BACN FROM PROPERTY LINE N_ 5_ E_ W Zme_ AppraW,torn InsOeeta (Specify whieh it front) ❑ ❑ ❑ ❑ DiaopDrand I . Z OTHER 7 3 . ORAW SNETCH Oft SHOW BELOW,THE FENCE, SIGN, OR OTHERSTRUCTURE,GIVINu (SETBACKS OR PROJECTIONS INCLUDED) ~ I ~ Mp~E I~GEn) rE S~~N Go~s 2 FRprtTh6-E h~FF T{F SHOW DISTANCES FROM THE MAIN BUILDING T6ADJOINING HOUSES, STREETS, AND DISTANCE TO PROPERTY LINES,NOT MAXIMUM OR pVERAGE DISTANt;E. ~ O 3 ~ < 3 PROPERTI LMES. Z J Y rc ie, vi /v ~ SPECIF NORTM IRREGULARIATS,SNOW LEAST APPLiCATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THISAPPLICATION WILL BECOMF A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EiXPIRE 180 DAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THATTIME. ELECTRICAL PERMIT STATE LICENSE NO. PLUMBING PERMIT STATE LICENSE N0. MECHANICAL PERMIT ALUMINUM WIRE UNOERSIZE B ILLEGAL fL00R BSM IST 2ND 3RD 4TH N0. ENeSda~ FLE4CirclsOn~ GW 011 poACoo Np, WATER CIASET FORCED AIR - BTU TEMPORARY METER WASH BOWI NOT WATER - BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-8TU LIGHTING SINN OTMER HEATING GARBAGE DISP REFRtGERATION SYSTEM POWER SUB-qFCUITS UTILITY(RANGE,DISPoSER,ETC.) FIxTURES WATER HEATER AUTO. WASHER DISH WASHER Refri sranf Grou Pamds Clwr • AUTOMATIC SPRINKLER SYSTEM WIRING MOTOF25 d CONTROLS FLIXOt DRAIN EIEVATOR $IGNS URINAL TRANSFORMERS 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURE$ PERMIT FEE NOT VALID UNLE55 RECEIPTED e thot thia opplico- kn wled A A q y ac o are I tion is torrect and undeisfand that I li- il fhi USE TAX s oDD Connof ttorf this project unt emion if ap0roved. I shall comply with TOTAL FEE - L( tAe lowa ot the State ot Colorado and to the Zoninq Requlations ond Bmleinp APPROVED . ~ Coee ot the City ot wnear Ri Qe. nny DISAPPROVED violatin te bve rmiii cause h ,City of Wheat Ridqe GH IEF BUILDING N ECTOR fion ihisip rmif ev r CALL234-5933 24 HOURS IN ADVANCE 4 Date Issued FOR INSPECTIONS a-le e Y 1'EH-R s o i✓ N ~ ~ m y N ~ U) a Zo on o W a = < n o < V ~ ~ ~ ~ m W m n~ ~ v ZiD L w a r o ~ aJy y W °D" 0 a m Z ~ 0 I ~ h m ~ , t--, m ~ a Z ~1z b r <s~ ~ r' ~ ~ ~V d c~~Cb ~ n m cyW~~~ a b N vv 1T-1 a~ Zt~ ~ b _ S Q ~ O W W ~ n' I ~ ~ m , i5s-60 - - - - - INSPECTION TICKET JOB ADDRESS J✓ ~~S (U~ DATE: I a "BLDG. PERMIT# 51C) PERMIT# BLDG. CONTR. l`"`"lj SUBCONTRACTOR S DATE INSP. REQ. TYPE OF INSP. - INSPECTION MAD ~ Vo REMARKS INSPECTION TICKET JOB ADDRESS Lo 3 ~ ~ !o~ ? DATE: 9---Z q~ BLDG. PERMIT# PERMIT# BLDG. CONTR. SUBCONTRACTOR DATE INSP. REQ ~ TYPE OF INSP. INSPECTION MADE e ~T REMARKS l'h, a -ti~-`'v W.R. FORM 619 ! DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 wEST29thnvENUE BUILDING INSPECTION DIVISION PERMIT N0. ME93#5560 234-5933 P.O. BOXSaa CITY OF WHEAT RIDGE, COLO. THIS PERMIT VAUD ONIY WHEN S16NED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTEDBELOW. JOBADDRESS w, `'v•'"° CONTRACTOR KRQiAv~T ELG-~l'~ZICAL C~c,~'YL.i 1v~c ADDRESS 7 7 7.7 W~Z /LE S~. y0 C I T Y 117's • ZIP CODE PinZZ f PHONE qZ9-33Z6 LICENSENO. Sy71 I. TYPE firound❑ Woll❑ OWNER . ADDRESS PHONE :21-6- ZCdJ ZIPCODE CONTRACT PRICE $ ~ OC°b I DATE ProitCtinn❑ . Ofier_-. 2. MATERIAL S1GNS 3, ILLUMINATION Yaa❑ No❑ Typs 4 SET BACK FROM PROPERTY LINE N- 5_ E_ W. (SOeeify which is fronl ) ❑ ❑ ❑ 1. TYPE SolidO Mon Thon 80% ODen❑ Less T MATERIAL FENCES 3. SET BACK FROM PROPERTY I,INE N_ S_ E_ W. (Soeufv which ii front) E-i ❑ ❑ OTHER Z 13. S ev A Fnes INSPECTION TICKET %S JOB ADDRESS ~ ~ DATE: S~ BLDG. PERMITM PERMITN BLDG. CONTR.y DRAW SKETCH OR SHOW BELOW,THE FENCE,SIGN,OR OTHER STRUCTURE,GIV (SETBACKS OR PROJECTqNS INCLUDED) . SUBCONTRACTOR DATE INSP. F TYPE OF INS INSPECTION REMARKS STREET N4ME SNOW DISTANCES FROM THE M41N BUILDING TQADJOINING HOUSES, STREETS, G DISTANCE TO PROPERTY lINES, NOT MAXIMUM OR AVERAGE DISTANCE. W.R. FORM &18 / APPLICATION FOR PLUMBING; ELECTRICAL; nnt~n,vnl rennni i THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIOATION BV THE BUILDING INSPECTION DIVISION. ocannir wii i FzPIRF 1ftf1 DAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THATTIME. ELECTRICAL PERMIT PLUMBING PERMIT MECHANICAL PERMIT STATE LICENSE N0. 3Ll~JZ, STATE LICENSE N0. ALUMINUM WIRE UNDERSIZE 8 ILLEGAL FLOOR BSM IST 2ND 3RD 4TH NQ Fl1EL:CetNOm GW 011 EbeSdar ~.~p. WATER CLASET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU )e NEW SERVICE ° AMPS BATH TUB STEAM - BTU f CHANfE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU IIGHTIN6 SINK OTMER HEATING GARBAGE DISV REFRiGERAT10N SYSTEM POWER SUB-CIFCUITS WATER HEATER Retri eront Group UTILITY (RANGE, DISPo5ER, ETC ) AUTO. WASHER Pounds CMr e FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTOF25 6 CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS B RECTFIERS $EWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARKS ~~L>T/~J(r C.)rlir /nM ~2 )(Jti1-TS i /q/>D na- Jc-rG"L'MZ- ~cL'Li12tC SE~CV~CE 3.0 I Aereby ocknowledQe that ihis applica- tion it Correcf ond understand tAat I connot slart this Drojecl unfil thia oppli- cotion is apOroved. I sholl comply wiih Ms laws oi the State of Colorado ond 10 ths Zoninp Repulotiona and Buildinp Code ofthe City ol Wheat Ridpe. Any violatior~of tne abova terma will couse imm~all fevp+catiqn pf, inie Permit PERMIT FEE S "j USE TAX 6, , TOTAL FEE $ 9 ,3. GLPI AP~Dp'`7 CHIEF BUILDIrp~ INSPECTOR,City of heat Ridqe Date Issued -t 3 NO7 VALID UNLESS RECEIMED z{ S 738q C/c.t1 CALL 234-5933 24 HOURS IN ADVANCE FOR INSPECTIONS "oli<an'. s'a , , ~ F O T l ~ j•~l l $ , T O I ( O ~ 0 z z ~ C n j D 1 N m 8 ~ ,I m m 0 m m ~Q ~ m a y ~ c o y ~ 0 y m ' N ~ O ~ " 3 0 3 ~ n ql c m ~ m m I- ~ ° ~ w c Q 9 a a ~ m m ~ m F 3 ~ F o r o ~ m w 0 ~.v.. ~ ' . r ~ v ~ VEPMRNUMlEN M93H19021 D ~ m ~ m 0 ~ o 9 m Z fy/1 O 1 0 O x 2 Z m a V ~ ~ ~ w ~ rl ~ < ~ C N ~ F~• rt ~ ~ O ~ ~ ~ w a . ~ N i O m O ; O W W O D v 0 x F y m n f g:Eai ~ ~ m 003 c m ~Dy} m nn- „ m m c ~ m m . y /1 dC ~ =com~ A 0 0 3ns~ lJ ~ ao mm m~o y 0~mm ~ ° _ ~ N m 5r ~m~3° 1~1 °~^c ^ \ • O ~ C j . ~ C) m ° o°O 0 m ~ ~ w~ o a§0 O ~ ° n~= ~ maan n LT' O J p~a~ a:Ip m<1 m o~ 9 O mm mv ~ n m m0~ ~ m ~ aQm m cv ~ < Q O WOV F~nl v0w ~ 0 ~ 3£a m . o m`"~ m \J F o m m mov o 3 E Z ~ a Q o m£m ~ o m O v ~ to W ~ r i; . 9 ~ ~tltr) ft la . INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 2346933 INSPECTION RECORD JOBADDRESS7615 W. 38th Avenue - B-107 BUILDING PERMIT N0. M93# 19021 OWNER Wilmore Center DATE ISSUED 10/13/93 I TYPE OCCUPANCY CONTRACTOR Trinity Construction Management Inc. 5645 W 109th Cir. Westminster CO 80020 SETBACKS fROM PROPERiY LINES: NORTH SOUTH EASi West INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB I NSPECTION DATE I NSPECTOH Foundations Footin s Caissons Reinforcin or Monolithic Weather roofin POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor: Electrical Ground Work Plumbin Ground Work Heatin Ground Work DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED Rou h Electrical Rou h Plumbin AirTest Gas Pi in Rou h Heatin &Ventilation (above must be sivned prior to framina insvecfion) Framin Insulation D wall nailin Roofin Refri eration Electrical under round Final ; Electrical Fixtures ~ Plumbin Fixtures Heatin 8 Ventilation Landsca e 8 Parkin R.O.W. & Draina e Fire De artment Job Com leted / U OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER )M r 4( G INSPECTION TICKET JOB DDRESS d3- ra~ DATE: BLDG. PE!RM TN PERMITB BLDG. CONTR. SUBCONTRACTOR DATE INSP. REQ. f S TYPE OF INSP. ~ i ~ INSPECTION MADE REMARKS W.R.FORM 619 DEPARTMENT OF CQMMUNITY DEVELOPMENT :ST29thAVENUE BUILDING ItJSPECTION DIVISION PERMIT N0. M93#19021 _.»-,933 P.O. BOx838 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SiGNED BY THE CHiEF BUILDING INSPECTORANDRECEIPTEDBELOW. JOBADDRESS 76 I5 ~'V 3~+Af~~~]~V CONTRACTOR Trin,14 Cc~nsf vmvnt. .Tt7c- i ADDRESS 5614 S w J09ftiC/HC_ CITY L✓PSf N+I HS f'Pr . ZIPCODE ?QO~° PHONE ^4' 6 4-693J- LICENSENO. 1611 q 1. TYPE Ground❑ Woll❑ 2. MATERIAL $IGNS 3. ILIUMINAT10N Yes❑ No❑ Type 4. SET BACK FROM PROPERTY LINE N_ S_ E. (Speti}y whiGA ia troM ) ❑ ❑ 1. TYPE Solido Mwe Thon 80% ODSn❑FENCES MATERIAL 3. SET BACK FROM PROPERTY LINE (Spetity whieh is }ront) OWNER IF- WJl,v1ore Cenfe, Trc- ADDRESS 17,Y6*- Cot'y'~v.r.,( j),.,,L„Q PHONE 74E '/0 0 D Zip CODE .eO_G,3 CONTRACT PRICE $ ~O 00 DATE ICZ//I 93 ProiectinpLJ OtMr S a D Fete Tofal Squon Fieaf Eleet. Pvmif No. - W _ Zoro_ ApprwW,ZOne Incpoota Less Thon 80% Opon N_ S_ E_ W Zme_ Apprwed,Zom InsOetiw ❑ ❑ ❑ ❑ Diaapprowd 0" . . 0r• _ .LI I. . ~ ' INSPECTION TICKET 7RUCTURE,G JOB ADDRESS ~ (Ol 3 ERTY LINE 16 /67 ~ ~ DATE: _ BLDG. PERMITM/ `Id PERMITk BLDG. CONTR. SUBCONTRACTOR °ERTY LINE DATE INSP. REQ. / U"lg TYPE OF INSP. ~ iES,STREETS, DISTANCE. G INSPECTION MADE ELECTRIC . iDICATED WOR REMARKS TE OF ISSUANC IYV 1 VPILIU VI'/LCJJ R ,0 ff .:5 7 i s IMBING PER ~ JSE N0 A BSM IST W q FORM 619 ~p ~ W.R. FORM 6-19 / / i~ OTNER HEATING GAR9AGE oisv REFRIGERATpN SVSTEM POWER SUB-CIFCUI75 WATER HEATER Refi ronf Gou UTIUTY(RANGE,DISPO5ER,ETC.) AUTO.WASHER ppwMt CAar e FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTOFtS B CONTROIS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS 6 RELTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARKS I MreDy acknowledpe tnot Ihis avvlica- PERMIT FEE fion ia correct and understand tnat i USE TAX tannof start this projntt until this op01i- eation is apvrovee. I zholl tomply witn TOTAL FEE the laws of the State of Colorodo ond fo the Zoninp Requlafionn ond Buildin0 APPROVED Code ofthe City of Wheat Ridpe. Any violation of tne obove terme wili cause CHIEF BUILDINimmediote revocafion of thia permit INSPECTION TICKET 3 JOB ADDRESS 77 (5o, 1S J DATE: BLDG. PERMIT# C~ PERMITN BLDG. CONTR. SUBCONTRACTOR DATE INSP. REQ. ID=;~ a TYPE OF INSP. ~ " Q/'. INSPECTION MADE REMARKS $ 6 9 o-e) I I l City of Wheat Ridqe ~ ~~-"Qi Date Issued l ZG1 oolieanb 9'I' amr. CALL 234-5933 24 HOURS tN ADVANCE FOR INSPECTIONS V {-33) 469-6938 Trinity Construction Management 5645 W. 109th Cir. Broomfield, Colo. 80020 8191 93 Wi I mOrG c enfer 3?*Ad wads<..nrtA suIte t3-/ os ~ , 0 J a S ~ ~ Alo.., Swit~4es /ve✓ ElecX OuYlvt P~tCn Q GNnen..l NuI`ef ,r^~MI(.1 C¢tllH~ eYi34IH,j Clerfo-~t[.I Fra3t~N~ plr.a.T~~~.y F~trJi~hS New w~.Us to Gr, d j y"MeiaL Stu<<s ee, lDovi^S 4) Reuse eu'sfiny F+) Nt' W.7vic Ee LP~Ja c y l{ C / --le.. DEPARTMENT OF GOMMUNITY DEVELOPMENT 7500 wEST29thAVENUE BUILDING INSPECTION DIVISION PERMIT N0. ME93#5588 234-5933 P.O. BOX638 CITY OF WHEAT RIDGE, COLO. THI$ PERMIT VAUD ONLY WHEN SiGNED BY THE CHIEF BUiIDING MSPECTOR AND RECEIPTED BELOW. I.HI IVrv r VIY MIJI.tLLFlNtVUJ Y KM~ JOB ADDRESS OWNEF CONTRACTOF ~--1's- S/_ADDRESS ADDRESS /7'7 3 ~ - 'F7 PHONE ZIP CODE CITY ,~~e~~tJlc~-- ZIP CODE CONTRACT PRICE $ PHONE '2'5_7-/T 3!~ LICENSE NO. ~<._,~.L DATE / 1. TVPE Ground❑ Woll❑ ProieclinQ❑ O1Mr SaDFeee 2. MATERIAL Tofal Spuan FNt SIGNS 3. ILWMINATION YOs❑ No❑ Type ElW. Pormit No. enrxF9nu aonocaTy LidF NS_ E_ W Zone_ Apprwb,Zom InaWiw ❑ I❑ Uu Tht ..n INSPECTION TICKET JOB ADDRESS ~ ' W t--i 3 t c ~ DATE: I G' a(' BLDG. PEAM TN PERMITM c BLDG. CONTR.(2!},~r~ ..6.1-- SUBCONTRACTOR DATE INSP. REQ. ( L " TYPE OF INSR ~ INSPECTION MADE~~ REMARKS ~ - W.R. FORM 6-19 PERMIT FEE USE TAX TOTAL FEE APPROVED~ JMBING PERM STATE LICENSE N0. STATE UCENSE N0. ALUMINUMWIREUNDERSIZE8ILLEGAL FLOOR BSM I5T 2ND 3RD 4TM NQ P.£l:CicMOn* Ga{qlRoporr EbeSdar N0. WATER CLASET FORCED AIR - 8TU TEMPORARY METER WASH BOWL HOT WATER BTU NEW SERVICE AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTIN6 SINK OTHER NEATING GARBAGE DISP REFRIGERATION SVSTEM POWER SUB-qFCUITS WATER HEATER Rafri eronl Group UTILITY(RANGE,DISPOSER,ETC.) AUTO. WASHER Poundt CMr e FIXTURES DISH WASHER AUTOMATIC SPRINNLER SVSTEM WIRING MOTORS 9 CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIxTURES REMAmcS S- ~ a t~~, l f5 7`r 5`~ 5~%` T I hsreby acknowladQe thot ihis applico- fion is eorrecl and underslond thot I eonnot fto.t tnie project until thls ovpli- eotion is ap0roveA. I shall comply wifn Me lawa of the State of Colorado and 10 }he Zoninp Requlationa and Buildinp Code olthe Ci1y of Wneat Ridqe. Any viololion of tAe above terme will couse immediate revocafion of tnie Oermit CHIEF BUILDIN - E- W- ~ ❑ JOB ADDRESS INSPECTION TICKET G / 5- tu. 3 80 - z'`~ Io DATE: /Q'( ~ BLDG. PERMITM ~~&F iTRUCTURE, GIVR 'ERTV LiNE PERMITN BLDG. CONTR. SUBCONTRACTOR DATE INSP. REQ_z~d_Ig PERTY LINE TYPE OF INSP. X~- INSPECTION MADE / ?/67 REMARKS iES,STREETS,A! ~ : DISTANCE. ELECTRICP W.q. FORM &19 IDICATED WORK i TE OF ISSUANCE NOT L UNLE55 / Lxf/ City of Wheat Ridqe ' I CALL2345933 / 24 HOURS IN ADVANCE Issued~/~ 1+5~/~~~ FORINSPECTIONS 7500 W EST 29th AVENUE 2345933 P.O. BOX 638 ecowT vei In ONLY WHEN JOB ADDRESS ~ CONTRACTOR ADDRESS ~ cirv l PHONE DEPARTMENT OF GOMMUNITY DEVELOPMENT BDY' OF INSPECTION C RIDGE, I OLIO.N CIT iME CHIEF BUILDING INSPECTOR AND RECEIPTED BETOW. Z1P CODE _ LICENSE NO. I. TYPE Grouna CI 2. MATERIAL SIGNS 3. ILLUMINATION Yes No~ TYpe- 4. SET BACN FROM PROPERTY UNE N~ ! (SDkify which ia }ronl ) I. TYPE Solid~ More Thon 90% MATERIAL.~------- FENCES 3 SET BAGK FROM PROPERTY LINE (SoaciN which ie }ront) I. OTHER Z' 3. N_.- S-- E _ NCES FROM PROPERTY LINES DR SE BACKS OR PFO E C ~0 5 INCIUDED)E,SIGN,OR OTHER STRUCTURE,GIVING DISTA. aFGR PROPERTV LINE ~r is N ~ SpECIFV NORTH STREET NAM&^~ $HOW DISTANCES FROM TME M41N BUIlDIN6 TPADJOINING MWSES, STREETS,AND PROPERTY LINES;ON IRREGULAA IATS, SMOW LceeT DISTANCE TO PROPERTY LINES, NOT MP.%IMUM OR AVERAGE DISTANI:E. qpPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT LDING THIS APPLICATIO PERMIB y~OILL MEXP RE n180 DAYS FROM THEEDATECOf 58UANCE I~F WORKOIS NOT STAR ED WITHIN TIHAT TIME.PECTION DIVISION. PLUMBING PERMIT MECHANICAL PERMIT ELECTRICAL PERMIT STATE IICENSE NO STATE LICENSE NO.~_ _UMINUM WfRE UNDER SIZE 8 ILLEGAI FLOOfi 85M IST 2ND 3RD 4TH N~. FUEL'C 0, 0 weTFR CIDSET fORCED AIR ~ BTU wr w~TCO - BTU _ - WASH BON'L IRARY METER BATH TU8 ERVIC iE SERVICE-AMPS SHOWER ING SINK ~nRBAGE DISP FLOOR p WIRING MOTORS 9 CONTROLS URINAL SIGNS SEWERS TRFNSFORMERS 9 RECTFIERS OTHER ADDITION TO OLD WORK TOTAL F ..nTnac nVER I HP . PERMIT FEE I hereby ocknowledpe thal thia eDD"C° d understand thaf I USE TAX tion n tmtecl on cannot starr tnis proj«ct until tnle avoli' it~ TOTAL FEE cotion is aDOroved. I sAall comply w tpe luws oi the State ol Colorado and to PpROV the Zoninp ReQulatlons and Buildin0 E D Cods of the Uty of Wheat Ridpe. AnY CHIEF BUyL'C se cou violotion of the above terms wil1 i~ rm immediate revocati a-al'~t"T9~ \ Date PERMIT N0. AW~ ~ W '7 c - -L ~ AD ESS ~ - ZIP CODE y PHONE ~ CONTRACT PRICEO$ 11 DAT~~- i i Wolly Proiecl p1hsr S Total Squan Fed- Epcf. Pomit-olo- Loss Than BO% OM^ Haiphf w _ Zone_- Apprwed,Z011411ImpeNa i CALL 2345933 24 HOURS IN ADVANCE FOR INSPECTIONS Tyylicanu S"namr. DEPARTMENT OF COMMUNITY DEVELOPMENT 7500WEST29thAVENUE BUILDING INSPECTION DIVISION PERMIT N0. M931i18905 234-5933 P.O. eoX638 CITV OF WHEAT RIDGE, COLO. THiS PERMIT VAUD ONLY WHEN SIGNED BY THE CHIEF BUILDING INSFECTOR AND RECEIPTED BELOW. _ ? i oeee C/ ~ n ~ ~ o OWNER r...... . v r ~ ADDRESS :ONTRACTOR 4DDRESS PHONE ZIP CODE CiTY ZIP CODE LICENSE NO CONTRACT PfiIGE-f DATE . PHONE und ❑ Woll❑ Proieolinp❑ I~or. S I O S Poae TYPE G 1 SIGNS ro . 2. MATERIAL To1al Sauon FaN ElW Pvmit No ❑ N ❑ 7 . . ype 3. ILLUMINATION Yss o 4 SET BACK FROM PROPERTV IINE N- 5_ E_ W Zone_ Apprwad,2ons lnspeela (SOati}y whitn is front ) ❑ ❑ ❑ ❑ Diaopprovsd 1. TYPE Solido More Tl+an 80% ODSnO Less Than 80% Open 2, MATERIAL HeiOh} FENCES 3. SET BACN FROM PROPERTY LINE N_ S_ E_ W Zons_ Approwd,Zono IntDecta (Specify which is front) ❑ ❑ ❑ ❑ Disapproved I . 2 :O:T H ER 3 . DRAW SKETCH OR SHOW BELOW, THE FENCE,SIGN,OR OTHER STRUCTURE,GIV1hu DISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) ~ SPECIFV NORTN STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TQADJOINING HOUSES, STREETS,AND PROPERTY LINES;ON IRREGULAit LATS, S110W LceeT DISTANCE TO PROPERTV LINES, NOT MAXIMUM OR pVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAI PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL FXPIRE 180 DAYS fROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN TNAT TIME. ELECTRICAL PERMIT STATE LICENSE N0. PLUMBING PERMIT 57ATE LICENSE N0. MECHANICAL PERMIT ALUMINUMWIREUNDERSIZE8ILLEGAL FLOOR BSM IST 2ND 3R0 4TH NQ FUEL+CirWOtrGoidlPropsr EI Sda Np. TEMPORARY METER NEW SERVICE - AMPS WATER CLASET WASH BOWL BATH TUB FORCEO AIR - BTU HOT WATER - BTU STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONOITIONING-BTU LIGHTING SINK OTMER HEATING GARBAGE DISP REFRICaERAT10N SVSTEM POWER SUB-CIFCUITS UTILITY(RANGE,DISPOSER,ETCJ FIXTURES WATER HEATER AUTO. WASHER DISH WASHER Refri aront Group PounAs CMr e AUTOMATIC SPRINNLER $YSTEM WIRING MOTORS d CONTROLS FI.OOR DRAIN ELEVATOR $IGNS URINAL TRANSFORMERS 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER 1 HP TOTAL FI%TURES n REMARKS A lIca- t ihia a th l d PERMIT FEE `1 pp o e Qe I Mreby ocknow ^ tion ia correct ond understand tnat I li- USE TAX / Z,\_ connot stort tnie prolbct until this app totion if oDCroved. I shall comply with TOTAL FEE $ tM low, of the State of Colorado ond ro the Zoninp Repulations and Buildinq ' Code of tne City ot wheat Rieqe. Any DISAP OVED violotion ot tne above terme will couse CHIEF BUILDING~F I SPECTOR, Cityof Wheat Ridqe immediate r vowfion oi t s p mit 2 ~ `3 ale ISSued 1selieanb 9ianamr• l. CALL 2345933 24 HOURS IN ADVANCE FOR INSPECTIONS , . , . . - - - M--~, tuImaw IE71100 c C-PL1~Lv^ 1/811c ~ Jl'~E (J• (OrJ ~j WHEAT~IDGG, GorH ~ / S~/~~ ,f.1v,~.L S<vt/l!G ~2 ~w"r• . ) f}dd d~c,}' S e%c. ~o ~ s~evv~-~ /.~MOa.~. of~F GVl~+~- ey-~. ) nsw d~„.,i~ u••.!/s s~,.v~*+..4 e2.~.~'d ) Mowt~ .darf~i.~+~'! o~D nr~✓ /Gl~~~os. Ltf~~l. ,it~w doD,e 4n s/ EX~own.rian ~lo ~ y oFG'«., sJAb u„i/ ~ p~;d G~~ all old~Dlw..6ra eEd S.J~.e»+ Cs~o.~4~ ~r P~-.a~ -(t b , COMMUNITY DEPARTMENT NPMENT F 1°`~~~` 7500 WEST 29tn AVENUE SPECTION DIVISIO N BUILDING CITY OF WHEAT RIDGE, COLO. pERM1T N0. 234•5933 P.O. BOX6se THIS PERMIT VALID ONI.Y WHEN SiGNED BY TFiE CHIEF BUILDING INSPECTOR AND RELEIPTED OELOW. APPLICATTION FnOR MISCELLANEOUS PERMIT ~ 1I JOBADDRESS L ~ v ~WNER ADDRESS 7IU I S IA ) 3~- ~ p, CONTRACTOR - `1 PHONE 7l? L) ~ ZIPCODE ADDRESS T PfiICE $ ~ ~ DE CONTRAC A CITY . ZIP CO Z= I ' hL l ol z PHONE LICENSE NO. DATE 4 I. TVPE GrounE ❑ Woll❑ Proietlinp❑ Othar S M D FoeG ~ 2. MATERIAL Tofal Squan FM SIGNS 3. ILLUMINATION Yea❑ No❑ TYDS Eloet. Pvmil No. 4. SET BACK FROM PROPERTY LME N_ 5- E__ W (SOscilywhioh isfronl) ❑ ~ Q INSPECTION TICKET 4. 7YPE SolidO Mort Than 80% ODan~ Lut 1 - MATERIAL JOB ~f/ AL FENCES 3 SET BACK FROM PROPERTY LINE N_ E_ W ADDRESS l(l; (Spstity whicA is front ) ❑ ❑ El OTHER 2DATE: 1!~. BLDG. PERMITS .3W 3. DRAW SKETCH OR SHOW BELOW,THE FENCE,SIGN,OR OTHER STRUCTURE,Gf (SETBACKS OR PROJECTIONS INCLUDED) PERMITM BLDG. CONTR q ~C~ SUBCONTRACTOR DATE INSP. REQ. TYPE OF INSP. 01n~~ liq 9 INSPECTION REMARKS 0 I ! 3 STREET NAME $HOW DISTANCES FROM THE MAIN BUIIDING TQADJOINING HOUSES, STREETS, W R FORM 619 DISTANCE TO PROPERTV LINES, NOT MAXIMUM OR AVERAGE DISTANCE. qppLICATION FOR PLUMBING; ELECTRI( THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WOR PERMIT WILL EXPIRE 180 DAYS FROM THE OATE OF ISSUANC ELECTRICAL PERMIT STATE LICENSE N0. TEMPORARY METER ....,,,rc _ n WIRING MOTORS 9 RS 9 REC OLD WORK RIHP 0 GIA LL; t11 I Mroby ocknowledQe ihat lhis oOG11ca- tion is correct ond understond thot I connot starf thie project until tnia apDli- cotion if apOroveC. I shall comply with tAs laws o1 the Sfa1e ol Colorado ond to fhe 2oninp Requlclions ond Bwldinq Code ofthe Gty of Wheot Ridpe. Any violalion ol the above terme will cause immediote revocoLOn of tnia Dermit ~yolic nl. 9lonemr. PLUMBING PERMIT STATE UCENSE N0. FLOOR BSM IST 2NC WATEP CLASET WASH @OWL I BATH TUB SHOWER SINK GARBAGE DISP WATER HEATER / AUTO.WASHER DISH WASHER FLDbR DRAIN URINAL SEWERS OTHER TOTAL FIXTURES ~V~ 1; iI~~ km ~ ~4 -E /U7 PERMIT FEE USE TAX TOTAL FEE „ ~ MECHANICAL PERMIT : CkcN OM Got ql Prapom G RCED AIR BTU T WATER BTU r.u - 9T11 ` NOT VAUD UNLE55 RELEIViEO L ~&4 ,at;p- 6164! $ ga a?• ~3 9 / APPROVED j~,~? DISAPPROVED CHIEF BUILDING JP SPECTOR,City of Wheat Ridqe I CAL12345933 ~ 24 HOURS IN ADVANCE FOR INSPECTIONS Date Issued C~ BUILDING DEPARTMENT 237•6944 Ext. 255 CITY OF WHEAT RIDGE ' . . Correction Notice f Job Located at j ~ ~ ...~t......... ~ ~ I have this day inspected this structure and these premises and { ~ have found the following violations of City and/or State laws 1 i governing same: 1 fI ........~/.:~..1:.<..........t.:.~.....~~................. a.. ~.~......r~,. ~ ......!..i<.'E..f.'...C..G . ~ t . . . . ~ .,L r .L:......- ~ I . . ~ u i ~ . f ~ . i . ~ a J { i You are hereby notified to correct the foregoing violations. ~ When corrections have been made, call for inspection. ! ` Date ° . z. . ~ Inspector for Building Dept. DO NOT REMOVE THIS TAG ~ FORM Wq6-ES L'-~^AnTMEiJT OF GOMMUNITY DEVELOPMENT 7500 WEST 29tn AvENUE BUILDING INSPECTION DIVISION PERMIT N0. ME93#5249 237-6944 EXT. 255 P.O. eox 636 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CH1EF BUILDiNG iNSPECTOR ANC RECEIPTED BEL^W. .i ecci 1c:GTiON FOR MISCELLANEOUS-PERMIT ) n JOB ADDRESS ! • - - CONTRACTOR MCBRIDE ELECIRIC _ ADDRESS 1860 W. HAMILTOV PL. CITY 94GLEWOOD ZIP CODE 80110 PHONE 761-6176 LICENSE NO. 916 SIGNS OWNER . ADDRESS - PHONE _.~.5<Z~P CODE CUNTRACTI~PRICE $ T ~L~-- DATE T_ 9 I. TVPE GrounC❑ Woli❑ Proieclinp❑ Othsr Sor DFOCs 2. MATERIAL f Total SQuan FeN 3. ILLUMINATION Yn❑ Nou TYDe ElW. Permit No. 1.-E-W Zone_Apprwb,ZOne InsWetor 0 Disooorwed INSPECTION TICKET ❑ Lm Thnn ~ INSPECTION TICKET F JOB i/i E_ W- . ADDRESS /b i DJOB - DRESS ( DATE: 10 '-g3 BLDG. PERMIAW~2101 z DATE: Y ~Q BLDG. PERMITM _ - PERMITM RUCTURE,GIVIIr3 BLDG. CONTR. SUBCONTRACTOR DATE INSP. REQ. r- ~WSb~f _ TYPE OF INSP. SR INSPECTION MADE REMARKS PERMITA RTV I.INE ~;n l C /C1 BLDG. CONTR. ~ f~'T- " - RTY L.INE STREETS,ANO ' . y./,q. FORM 6-19 STANCE _ECTRICAL ATED WORK ON ~ JF ISSUANCE IF SUBCONTRACTOR DATE INSP. REQ. ~5 3 ~ TYPE OF INSP. INSPECTION MADE / 3 ~3 REMARKS ~ W.F. FORM 619 ~ rCrcMll PLUMt11N(i YtF(MII STATE IICENSE N0. 19 STATE LICENSE NO _ ~ ALUMINUMWIREUNDERSIZE8ILLEGAL FLOOR BSM IST 2ND 3RD 41H N0. FUELCirdsOrrGaidlPlopoM ElxSolor AIR - BTU WATER CLDSET FORCED ~ TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE - AMPS BATM TUB STEAM - BTU AIR CONDITIONING-BTU CHANfiE SERVICE-AMPS SHOWER LIGHTING SINK OTHER GARBAGE DISP REFRIGERATION SYSTEM HEATING POWER SUB-CIFCUtTS WATER HEaTER Reiri erant Group ETC) DISPOSER UTILITY(RANGE AUTO. WASHER Pounds Chor e , , AUTOMATIC SPRINNLER SYSTEM FIXTURES DISH WASHER WIRING MOTOFtS 9 CONTROLS FLIXNR DRAIN ELEVATOR SIGNS URINl1~ TRANSFORMERS 8 REC7FIER5 SEWERS ADDITION TO OlD WORK OTHER MOTORS OVER I HP TOTl+L RXTURES ~ i herlDy ocknowled9e that this 01,1311Ca- tion ie Corrett ond understand that I connot stort this project until thie a0vli- Cotion is opProveG. I shall tomply with ihe laws of the Srote ol Colorodo and to }h! ZoninQ Requlati0ns and Buildinp Code of the City of Wl+eat Ridpe. Any violation ol fhe above terme will eause immediate revocatron of tnis permit ~ --NOT VALID UNLESS RECEIPTE[ PERMIT FEE S~ rQ t+ s'( $ Gc) USE TAX . ~D TOTAL FEE 30 APPROVE~ ~ ~ i~(c l-~~2f 3 Z CHIEF BUILDI INSPECTOR,Cityof Whe Rid9e CAL1237- 4 EXT.255 24H OUR DVANCE G~ FOR SPEC S Date Issued__ ~ INSPECTIONS WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE (303) 234-5;;~. INSPECTION RECORD ~ IOBADDRESS 7615 W. 38th Avenue - Unit #13-103 BUILDING PERMIT N0. M93#18670 DATE ISSUED 3/23/93 NPE OCCUPANCY OWNER Con Am, 3345 S. Wadsworth Blvd, #220 - 988-6000 CONTRACTOR C. fi 1('onatrnvtinn C'n ~ Inc SETBACKS FROM PROPERTY LINES: NORTH SOUTH EAST West INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB I NSPECTION DATE I NSPECTOR Foundations Footin s Caissons Reinforcin or Monolithic Weather roofin POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Slab Floor: Electrical Ground Work Plumbin Ground Work Heatin Ground Work DO NOT POUR FLOOR UNTIL ABOVE F~AS B~EN SIGNED Rou h Electrical Rou h Plumbin AirTest Gas Pi in Rou h Heatin & Ventilation (above must be siqned prior to iraminq inspection) „ Framin ' Insulation Dr wall nailin Roof i n Refri eration Electrical under round Final Electrical Fixtures Plumbin Fixtures Heatin 8 Ventilation Landsca e & Parkin R.O.W. & Draina e Fire De artment Job Com leted 4CCUPANCY NOT)PERMITTED UNTIL CERTIFICATE OF in le+e+~lf-n DEPARTMENT OF CQMMUNITY DEVELOPMENT 7500 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT NO..-~~ 237-6944 EXT. 255 P.O. eoX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. JOB ADDRESS ~S_.~rs. O- i a 7 CONTRACTOR S/G - G" ADDRESS 14 1" CITY ZIP CODE [ n.,c i5t10/ OWNER L Y • ADDRESS 7Gg15* P PHONE jV L 7- c 'y 3L ZIP CODE nc 3CONTRACT PRIGE 'H ONE J ~ - ` ' ~i..~.o~ . 1. Ground ❑ L /~L r',f-i .1 d WallZ ~ Pro1ectin4❑ - Other 5 or D Face ~ Tofal SQUaro Feet r ~ TION YesZ No❑ K FROM PROPERTY LINE N TYPe _ S- E - W ❑ ❑ Elxt. Parmif Na. Zona_ QDD~oved,ZOne Inspector roved Di ~i (Specify whiCh iafront) ❑ ❑ soDD 1. SolidO More Thon 80% OpenD Laea Thon 80% Open FENCES L 3. SET BACK FROM PROPERTY LINE N _ S_ E _ W ❑ Heiqht Zona_ Apprwsd,Zone Inapecior rovBd Di (Specify whiCh ia front) ❑ ❑ ❑ saDD I OTHER 2 3. DRAW SKETCH OR SHOW BELOW,THE FENCE,SIGN,OR OTHER STRUCTURE,GIVih3 DISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) REAR PROPERTY LINE w w z J A^ J F f i! ~ L • ~ ~ ~ ~'N7 ~ ~w w a ~ 0 ¢ a w O Ja~ N N FRONT PROPERTY LINE STRtET NAME 3 B A -r, ~ SPECIFY NORTH SHOW DISTANCES FROM THE MAIN BUILDING TO ADJOINING HOUSES, STREETS, AND PROPERTY LINES;ON IRREGULAR LOTS,SHOW EA DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT r,n nev O SP FROM R DATE OF INDICATED O WORK S OT STAR~TED WITHW H THAT BUILDING INSPECTION DIVISION. THIS APPLICATION WILL PERMIT _ . _ PLU MBING PER MIT MECHANICAL PERMIT ELECTRICAL PERMIT STATE LICENSE N0 STATE LICENS E N0. . M IST 2ND 3RD 4TH N0. Fl£UCircbOneGaSqlPropanaCOalEleeSolor ALUM INUMWIREUNDERSIZEBILLEGAI FLOOR BS BTU FORCED AIR N0 WATER CLOSET . _ HOT WATER BTU TEMPORARY METER WASH BOWL STEAM - BTU NEW SERVICE - AMPS BATH TUB AIR CONDITIONING-BTU CHANGE SERVICE - AMPS SHOWER OTHER LIGHTING SINK REFRIGERATION SYSTEM HEATING GARBAGE DISP Re}ri erant GrOUp POWER SUB-CIRCUITS WATER HEATER Pounds Char e UTILITY(RANGE,DISPOSER,ETC.) AUTO.WASHER AUTOti1ATIC SPRINKLER SYSTEM FIXTURES DISH WASHER EIEVATOR WIRING MOTORS 9 CONTROLS FLOOR DRAW SIGNS URINAL TRANSFORMERS 8 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARKS - PERMIT FEE I hereby acknowledQe that this appllcu tion is correct and understand that I USE TAX connot start this project until this appli- cotion is approved. I shall comply with TOTAL FEE the lows of the Stote of Colorodo ond to the ZoninQ Re9ulations and Buildinp DISAAPPROVED PPROVED Code of the City of Wheai RidQe. Any _ violation of the above terms will couse CHIEF BUILDING immediute revocalion of ihis Dermit. Date Issued Applicanb Sipnawn NOT VALID UNLESS $ /.,5-° ,City of Wheat Ridge j v-cr 3 CALL 237-6944 EXT. 255 24 HOURS IN ADVANCE FORINSPECTIONS 7500 WE31`29thAVENUE DEPARTMENT OF COMMUNITY DEVELOPMENT 234-5933 p.rrBOX638 BUILDING INSPECTION DIVISION i PERMIT VALID ONLV WHEN SIGNED BY THE CH~fF aITiY~OF,wHEA7 RIOGE, COLO. JOS qDDRESS 7r/S W3'~'~ APPUCATIO- N Fp 8 a CONTRACTOR A.vT-2n,Af,R ~ rNG ADDRESS _~y~a So Y~ CITY PHONE - ZIPCODE Sr0„i3/ _ 6y LICENSE NO. ANC OWNER ro z_ ADDRESS PERMIT N0. ME93#5235 PHONE _p,gg' 60 0u CONTRACT PRICE $ U O Oi ZIP CODE 1. TYPE Ground ❑ I DATE y l3 2. MATERIAL SIGNS Wall❑ Proiecfin0❑ Ot"" 3. ILLUMINATION Yse❑ No❑ Type s or D FaI Total SQuon Fas} 4.SET BACK FROM PROPER7Y lWE N 5 E4ct. Par mi} N0. (Specity whitA ia hont ) I TVPE ~ ~ E W Z111A ~ ~ pDr°~'ed,2on~lnsp~etor . SolidO MATERIAL More Than BO% O FENCES DSnO Ltms Thon BO° / o Diaopprwad 3. SET BACK FRpM ppppERTY LINE N e pen HeiCM (SVeeify whien it tront) 1 S ~ E ~ _ W ❑ ❑ Zons__ qGDraW,Zon* Inspecta . Di~aPDrov-d oTHr^ 2 - -1 DR~ "r«%I ION TICKET ( JOB ADDRESS --~BLDG. PERMIT# BLDG. CONTR. iC-`"`Q~RMu~ P SUBCONTRqCTOR DATE INSP. REQ. (1-( ~ SH( TYpE OF INSP. C INSPECTION MqDE L.I V U REMARKS 3 ST/ AWMIh J NO W.R. F , ~M~19 ~wn~s ~ DISP kMERS 8 RECTO OLD WORK )VER I HP ~ I Aereby ocknowledqe tAot this oDGlica- lion ia correct ond undere}ond fhof I :annof ltarf thif prOjtlCf unfil thie oppli- i0110n is oOProveE. I sholl comply wi}p As laws o1 Ihe Stole o/COloroEO ond fo is Zoninp Repulalione ond Builtlinp ode oftAe Cify ot Whaoi Ridpe. Any olofion of tAe obove ferme will couse imediate revocafion of tnis permit i -(7 e r so i . ~ SPECIFY NORTN fREETS, AND PqppERTY LINES; ON IRREGULqp LpTS, SHOW LEAST 4NCE. CTRICAL; MECHANICAL PERMIT ED WORK ONLY UPON VALIDA710N BY iHE BUILDING INSPECTION DIVISION. 6SUANCE IF WORK IS NOT S7AR7E0 WIiHIN THAi iIME. 11 PERMIT I , . . - , & $ 7DISAPPROVED ~_✓~I;SPECTOR,City of Wheat Ridge Date Issued_ TURE, GlVlku" DISTANCES FRpM PROPERTY NES MECHANICAL PERMIT ~ rt - Y cF7~/ S 9 ~ CALL 2345933 24 HOURS IN qDVANCE FOR INSPECTIONS ~ M ) O Q ~ ~z ~n Zz, ~V ~ ~ ~ ~ e`I V Z PA/?lt'lN 6 F 115" V ~ ~ ~ ~ ~ ~ ~ ~ T M ~ ~ h ~ r l V~ Q ~ v ~ : ~ . . Y ^ \ O~ .U\Y- ~ e O Z ` ; 'J v 1iNN NN~.1 A>A PN~ N ~ O O N O O O VI N N T T T 1~1 T T ti ti y N N N 1 0~ 1.8 METER VSAT AZ/ a a "E F ° m m m m m m • ~ 1 U m z a m H i = G Z n t~ m Or C m s m x a c~ r ~ ~ z s m m m ~ 'DZ v i i a v i c 0 -O ~ H , a r o m z z c + m a a v Z y c z m s - m n ~ ~ . . m $ v a v m a 2 oz Q 0 i O O N ~ ~ O O Y~ • m ~ ~ ~ m ~ ~ I W C13 ~ z H u ~ K < K K K « -TC ~ ~ ' - . D Y Y Y Y M Y Y N VI 9 N N N N N U 41 ~ ~ ~ O -1 J J J J J J J W 4 N ~ m L1 + N r U N r p Zz Z D G ' DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT N0. Mp92#3346 237-8944 EXT. 255 P.O. BOX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIP7ED BELOW. JOB ADDRESS CONTRACTO k IKt• ~ c ( 1 ,9 ~ ny J ADORES a3~~ M S$ S ` CITY ZIPCODE 9 1o ] (1 P- l'~`~~ I ircr.iec ~in Itn / 37S OWNER PHONE ~ CONTRACT PRICE $ ZIP CODE rn ~rvc - ^ ❑ ll❑ W Proiectinp❑ OtMr SorDFate I. TVPE6round 2. MATERIAL ❑ o Total Squore Feet Permit No El tt $IGN$ 3. ILLUMINATION Yea❑ No 4. SET BACK FROM PROPERTY LINE N TYCS _ S- E ❑ _ ❑ W ❑ . . e Zons_ Approved, 2ona Inspeeta Drwsd Diw (SDaeily whicA is front ) ❑ D 1. TYPE Solido Mora Thon 80% ODenO MATERIAL ? Lo st Thon 80% Oqn HdpM FENCES , 3. SET BACK FROM PROPER7Y LINE N _ S_ E _ ❑ W ❑ ione_ ApprwW,Zone Impeota rovad Diso (Speci}y wryieh itfront) ❑ ❑ DD I. OTHER 2' a. DRAW SKETCH OR SHOW BELOW, THE FENCE,SIGN,OR OTHER STRUCTURE,GNIhu DISTANCES FROM PROrtKi r urves. (SETBACKS OR PfiOJECTIONS INCLUDEp) ~ SPECIFY NORTH STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TQADJOINING HOUSES, STREETS, AND PROPERTY LINES;ON IHREGULAR LDTS, SMOW LEAST DISTANCE TO PROPERTY IINES, NOT MA%IMUM OR AVERAGE OISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLiCA710N~1„ BEWOM cY~RRM nes FRM R DATE OF ~ ISSUANCE ~ WORK Y IS UNOT STAR~TED WIBTHW THAT Tlf,l~ INSPECTION DIVISION. MECHANICAL PERMIT ELECTRICAL PERMIT PIU MBING PERG MIT STATE LICENSE N0 STATE UCENS E N0. J? Q . IST 2ND 3RD 4TH NQ FUEUC'xclsOneGoid~R'~N ElxSolor ALUM INUMWIREUNDERS12EBIlLEGAL FLOOR BSM T WATER CLASET U FORCED AIR - B NO FqT WATER BTU WASH BOWL TEMPORARY METER STEAM BTU NEW SERVICE AMPS BATH TUB AIR CANDITIONING-BTU CHANGE SERVICE-AMPS SHOWER OTMER 116HTING SINK REFRIGERATION SYSTEM HEATING GARBAGE DISV R Refri aranl GrWp ppWER SUB-LIRCUITS WATER HEATE p~~d~ ~~r e UTILITY(RANGE, DISPOSER,ETCJ AUTO. WASHER AUTOMATIC SPRINKLER SYSTEM FIxTURES DISH WASHER ELEVATOR WIRING MOTOFtS 9 CONTROLS FLO)R DRAIN SIGNS URINAL TRANSFORMERS B RECTFIERS SEWERS ADDITION TO OLD WORK OTHER RES . MOTORS OVER I HP . TOTAL FIXTU C . L L. , n . 1 L i T~ iJ/ri~. 1 hareby acknowlad9e thot fhis opplica- tion ia Corroct ond understond H+af I pcnnpf ftort this project unfil this opDli' cotion it approved. I shall comply with ths laws oi Ihe Stote ol Colorado and lo ihe Zoninp Requlationa and Buildina Code of the City of Wheai Ridqe. Any vioiafion of the above terme will couse i 'ote revocatn of t ia pe if b0 a b Si0 a ur~ L 19 -J'L.~HPA .M W J / V v-r v %Z1,.J1 VL ~4 S /~Etia-~ 7 LI D PERMIT FEE NOT VALID UNLESS RECEIPTE[ USE TAX U TOTAL FEE $ j ~✓ye AP ROVEp P SARP CHIEF BUILDI NSPECTOR, City o heat Ridqe CALL 237-8944 EXT. 255 24 HOURS IN AOVANCE FOR INSPECTIONS Date Issued w, 7500 WEST 29th AVENUE 237-6944 EXT. 255 P.O. BOX 638 JOB ADDRESS CONTRACTOR L ADDRESS CITY PHONE~ SIGNS ONLY WHEN SIGNED BY DEPARTMENT OF COMMUNITY DEVELAFMENT B DI CITY OF W EAT RIDGE, COLO.N ...nrr c.in nwr. ~NSPECTOR ANDRECEIPTEDBELOW. OWNER PERMIT N0. ME92#5134 PHONE ZIP CODE :ONTRACT PRICE $ ZIP GODE ~ OMSr S a D FatO Woll❑ Proiectinp TYPE Ground ❑ Tofal Spuon Feat 2. MATERIAL Elmt. Parmit No. 3. ILLUMINATION Yea❑ No❑ TY7s E__W Zone_ ADMovb, ZO^e InspOeta 4. SET BACK fROM PROPERTY LINE N__ S a ❑ ❑ DiwpDrwed (SOkify whieh ie fronl ) ❑ _ I. TYPE SolidO Mon Thon 80% pDs~~ L~~t TAOn 80% OM^ H~ipM MATERIAL Zp~~__ ApDrwW,Zon~ IntPwtw ZES 3 SET BACK FROM PROPERTY LINE N_--- 5~- E--- W ❑ ~ ~ pisapp~ov~d (Soetitv whieh is 1rOM) ~ 1. OTHER 2 3. pRAW SKETCH OR SHOW BELOW. THE FENCE,SIGN,OR OTHER STRUCTURE,GIV1hG DISTANCES FROM PROPERTY LINES. (SETBACKS OR PRO.""T'^"1° INa IIDED) ~ $PECIFV NORTH STREET NAME $HOW DISTANCES FROM THE MAIN BUILDING TUADJOINING 110USES, STREETS, AND PROPERTY LINES~ ON IRREGULAR LATS, SHOW ~EAST DISTANCE TO PROPERTV lINES, NOT MAXIMUM OR AVERAGE DISTANCE. qPpLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT TIME INSPECTION DIVISION. THIS APPLICATION ~RMITEyOILL MEE%PIREM60 DAYS FROMR DA EEOFDIISSUANCEO'.F M~ORKYISUOT S VAL Ai~TE W TH IBUILDING MECHANICAL PERMIT ELECTRICAL PERMIT STATE IICENSE N0. PLUMBING PERMIT STATE LICENSE N0. AIR SEWERS a I Aeraby ocknowladpe thot thia app"ca' tion ia eorrect ond underatond thof I eonnot ftmt tAis proleet unfil thia op0li' eation is aDCraVed. I ahall comply with the low, of Ihe Slote of Colorado ond 10 ths ZoninQ Reputations ond BuildinQ Code ot ttie City oi WI+ea1 Rid9e. AnY violotion ol the above terms will cause immediote favocotion of this Oefmit. u PERMIT fEE USE TA ~ TOTAL FEE $ ApPROVED G CNIEF BUILDI INSPECTOR,C' of Whem Ridqe CAL1237-8944 exT. 255 24 HOURS IN ADVANCE FOR INSPECTIONS IZe Issued DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 WEST 29tn AvENUE BUILDING INSPECTION DIVISION PERMIT N0. M92#10% 237-6944 ExT. 255 P.O. BoX sae CITY OF WHEAT RIDGE, COLO. 185031 THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED 8EL7W. „ u v i ~n m1o~,CLLHryGUUJ YCI'( 'PAI I - JOB ADDRESS s lls i OWNER ~ S7&71E/iPTJEA CONTRACTOR /Iq C E ~ . ADDRESS 3'3YS ~ONTl//Clcz'Sw/d,rT4 ADDfiESS~ OS CTPHONE ZIPCODE,90r27 ~ CITY ZIPCODE 6OS~O~ :ONTRACTPRICE$ a ~v(~'Q/'DPHONE -2 77 l6 9 9 . LICENSE NO. L TYPE Ground❑ Woll❑ Proiectinq❑ Other SaDFOOe SIGNS 2. MATERIAL 3. ILLUMINATION Yss❑ No❑ TyOe Tolol Squore Faaf Etea1. Permi} No. 4. SET BACN FROM PROPERTY LINE N (Spxify whicA is front) _ ❑ S_ E ❑ _ W ❑ ❑ Zona_ ApproveA, 2ons Inspecta Diaapprowd 1. 7YPE Solido Mora Than 80% ODanO Less TAOn 80% Open MATERIAL Hei ht FENCES 3. SET BACK FROM PROPERTY LINE N (Spsci}y whieh is tront) _ ❑ 5_ E ❑ _ W ❑ ❑ Q Zons_ ApprwW,Zons Impeetor Diaapproved 1. ;7-zn -41r l OTHER Z 3. DHUW SKETCH OR SHOW BEIOW,THE FENCE, SIGN, OR OTHER STRUCTURE,GIVih'v UISTANCES FROM PROPERTY LMES. (SETBACKS OR PROJECTIONS INCLUDEA) SPECIFV NORTH STREET NAME SHOW DISTANCES FROM THE MAIN BUILDIN6 TQADJOINING MOUSES, STREETS, AND VROPERTY LINES{ON IRREGUTAR LATS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATtON FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILI. BECOME A PERMIT TO PERFORM THE tNDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 60 DAYS FROM DATE OF ISSUANCE !F WpRK IS NOT STARTED WITHW THAT TIME. ~ ELECTRICAL PERMIT STATE LICENSE N0. PLUM8ING PERMIT STATE LICENSE NO. MECHANICAL PERMIT ALUMINUM WIRE UNDERSIZE B IILEGAL FLOOR BSM IST 2ND 3RD 4TH N0. FLEL+ChcbOe» CwFqlProqns ElaeSolw N0. WATER ClASET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-CIFCUITS WATER HEATER Retri sront Wou UTILITY(RANGE,DISPOSER,ETC.) AUTO.WASHER poundt Char s fIXTURES DISH WASHER AUTOMATIC SPRINNLER SYSTEM WIRING MOTORS 6 CONTROLS FLDOR DRAIN ELEVATOR SIGN$ URINAL TRANSFORMERS 6 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTIIL FIxTURES I Asreby ocknowledqe that thia applica- fion is eorrect and undersfand tAat I tannof ftarf this Drojett until thia oppli- cation is opprove0. I sholl comply witA fhe lowf of fhe Stote of Colorado and to fhe Zoninq Requlotions ond Builtlinp Code of the Cify of Wheaf Ridqe. Any violalion of the obove terme will cause immediote revocation of thie permit. ~ c o canM1 SiO~^~ur~ PERMIT FEE C ci USE TAX TOTAL FEE $ ~ (l NOT VALID UNLESS RECEIPTED 9 T~rlvv b~ ~r a 3 t 7 CHIEF BUILDINqINSPECTOR,Cityof WheatRidye Dafe Issued _1D CALL 237-6944 EXT. 255 24 HOURS IN ADVANCE FORINSPECTIONS ~e) S INSPECTION TICKET JOB ADDRESS _ :Z~c` (S W . ~ ~ fi~ /,Z' i J DATE: 9I ID BLDG. PERMIT# I,S S`r3 INSPECTION TICKET JOB ,J ADDRESS - ~ ~ ~ DATE: A BLDG. PERMIT# J13 PERMITA BLDG. CONTR.4 SUBCONTRACTOR pr'P. DATE INSP. REQ. TYPE OF INSRj - INSPECTION MADE "C? ( REMARKS tiJ-JV ~ ~ ~~y - INSPECTION TICKET JoB ADDRESS ~62i5 Gk)- 3$t:sA&toi DATE: mq ~gLDG. PERMIT# .~J PERMIT# BLDG. CONTR.1(,C.A~V1'4k q1 !l!T'~Q.D FIIRl:nNTCerrnoI DATE INSP. REQ. TYPE OF IN SP. INSPECTION MADE REMARKS W.R. FOFM 6-19 PERMIT# BLDG. CONTR. SUBCONTRACTOR ~i DATE INSP. REQ._ZL - 1`7 TYPE OF INSP. -~C--L-Q INSPECTION MADE_ REMARKS_ Oi `2 `I I7 e1 k o INSPECTION TICKET JOB ADDRESS DATE: BLDG. PERMIT# 33V1, PERMIT# BLDG. CONTR. C!ti-%-_x_o . ~j SUBCONTRACTOR DATE INSP. REQ. 11-1~2 O~TYPE OF INSP.--I'- INSPECTION MADE REMARKS LO/ W.R. FORM 61g ✓ ~ ya ~~~sa3 - - - - - - ~ a- - y INSPECTION TICKET JOB ADDRESS / ~ ~ ~ W ~ 1~lk A z ~cJ ~ DATE: BLDG. PERMIT# PERMIT# BLDG. CONTR. 0-p' ~--a' ~ - SUBCONTRACTOR DATE INSP. REQ. TYPE OF INSP. INSPECTION MADE REMARKS INSPECTION TICKET Joe C~ ADDFESS 5 ~ DATE: I l J~ BLDG. PERMIT# PERMIT# BLDG. CONTR. & J~/ SUBCONTRACTOR DATE INSP. REQ. TYPEOFINSP.~~"-~"` INSPECTION MADE LI '3 v ~Z REMARKS W.R. FORM 8-18 y 7500 WEST29thAVENUE DEPARTMENT OF GOMMUNITY DEVELOPMENT 234-5933 P.O.BOx638 BUILDING INSPECTION DIVISION PERMIT N0. ME93#5221 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SiGNED BY THE CMiEF BUILDING INSPECTOR AND RECEIPTED BELOW JOB ADDRESS CONTRACTOR < PHONE SIGNS FENCES OWNER PHONE _ CODE CONTRACT l- e Z-ena-~~)_. LICENSE NO. ~ 2S I DATE I. TYPE Ground ❑ Woll❑ Proietlin ❑ Ofh 2. MATERIAL Q sr S or D Face 3. ILLUMINATION Yes❑ No❑ Typs Tofal Squon Fnf 4. SET BACK FROM PROPERTYI.ME N S E El~e}. psrmit No. _ (SDecify whith is frenf 1 n _ n _ W n rl Zone_ Apprwad,2ono lncpeo}pr 1. TYPE SolidU Mon Thon BO% Opan❑ MATERIAL 3. SET BACH FRpM PROPERTY LINE (Spetify whieh it }ront) I. OTHER 2 13. S__ ❑ Hoiphf N' ^ 2one_ ADDrwW,Zonis Impeefa DRAW SKETCH OR SHOW BELOW, THE FENCE, SIGN, OR OTHER STRUCTURE, GIVIIiG DIST4NCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) ~ SPECIFY NOFTM ~ N STREET NAME SHOW DISTANCES FROM THE MAIN BUIIDING TOADJOINING MOUSES, STREETS,AND PROPERTY LINES; ON IRRECULAft LATS, SMOW LEAS7 DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANI;E. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE Bl11lDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT PLUMBING PERMIT MECHANICAL PERMIT STATE LICENSE N0. o~ a 5 1- SiATE UCENSE N0. AIUM INUMWIREUNDER$IZE8ILLEGAL FLOOR BSM IST 2N0 3RD 4TN N0. Fl1ELCirUeOn~Go{dlRopar EqeS l NO, WATER CLASET o m FORCED AIR - BTU TEMPORARY METER _ WASH BOWL HOT WATER - BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER LIGHTING AIq COHDITIONING-BN SINK M ER OT HEATING GARBAGE DISP REFpIGERAT10N SYSTEM POWER SUB-CIRCUITS WATER HEATER Refri e.ont Group UTIUTY (RAN6E, DISPO5ER, ETC.) AUTO WASHER . Pounds Cna- e FIXTURES DISH WASHER AUTOMATIC SPRINKIER SYSTEM WIRING MOTORS B CONTROLS FI Dq2 DRAIN SIGNS . URINAL ELEVATOR TRCNSFORMERS 9 RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FI%TURES REMARKS_-/~,/l~l%~.~i I Aereby ocknowiadQe thot thie appiico- PERMIT FEE tion n correct and understand thot I USE TAX cr0 cannof start tAis project until thia appli- wtion is approved. I snan oomply wrtn TOTAL FEE ~qo $ tha lawf of fhe State ol Colorado and 10 fhe Zonina ReQulationa ond Builtlinp AppROVE Code otthe Cify of Wneot Ridpe. Any violation of tne Ja1bove terme wiii cauee CHIEF BUILDI INSPECTOR,Cityof i imm~diqty'r~vo,cption of ihi,p p9rmit Leu Than 80% NOT VALIO UNLESS RE( !e €f v ~a c) Ridqe CALL2345933 24 HOURS IN ADVANCE Date Issued -~?-a.~ " 5~ -3 FOR INSPECTIONS ,11 ~~ca-f~ -6Z-' L', I BUILDING DEPARTMENT 237•6944 Ext. 255 j i CITY OF WHEAT RIDGE • • Correction Notice _ • , , 171 j ~ Job Located at I have this day inspected this structure and these premises and have found the following violations of City and/or State laws governing same: ~ ~ ~ ~ ~ 0 ii . ~ r)LL~.Gh:. ~ ~ ~ . , v v , r ' , : i t ~ ~,.4 j .....a . , You are hereby notified to correct the foregoing violations. When corrections have been made, call for inspection. > > ~ . , Date...... ..::..1................................ i , . r Inspector for Building Dept. DO NOT REMOVE THIS TAG FORM WR6'22 .9- 5 INSPECTION TICKET JOB ADDRESS ~ ~ ~ s bJ - 3 8 ti- DATE: J BLDG. PERMIT# 52 a~ PERMITM BLDG. CONTR. C ' SUBCONTRACTOR DATE INSP. REQ. 3 ~ TYPE OF INSP. ~ INSPECTION MADE J 2 ~ 4 REMARKS / / ~ ZIL INSPECTION TICKET aos 3~~jk- ADDRESS .tf 16 la 3 a yvt ~ 9 3 DATE: ✓ BLDG. PERMITB PERMIT# BLDG. CONTR. ~ & SUBCONTRACTOR DATE INSP. REO. TYPE OF INSP. J -)q J~ INSPECTION MADE REMARKS Q•2~1 ~ 3 W.R.FORM 6-19 / / / ti INSPECTION TI CKET JOB ADDRESS CJN- ~ ~ ~Q J F~ DATE: BLDG. r PE~RMITN> ~ Zz I ~ PERMI TN ✓ BLDG. CONTR. SUBCONTRACTOR DATE INSP. REQ. 4 -(D TYPE OF INSR~'t- INSPECTION MADE 0 REMARKS W.R. FORM 6.19 d' 7500 W EST 29th AVENUE 234-5933 P.O. BOX638 THIS PERMIT VALID ONLY WHEN SiGNED E JOB ADDRESS ~G /S 4", , 2k r~~J< r CONTRACTOR (2.ltz ADDRESS k4rO vX DEPARTMENT OF COMMUNITY DEVELOPMENT M93#18670 BUILDWG INSPECTION DIVISION PERMIT N0. CITY OF WHEAT RIDGE, COLO. Y THE CHIEF BUILOING INSPECTOR AND RECEIPTED BELOW. APPLICATION FgR MISCELLANEOUS PERMIT~y OWNER ADDRESS 3ZC`~S/~ S• L.3A`(SY/a/~l~ 1.Y(."~I 2Z`'' PHONE 21P CODE GL2 ~ CITY ZIPCODE G"c&-'Z PHONE LICENSE N0. CONTRACT PRICE $ DATE 3 L TYPE GrounA ❑ Woll❑ ProietlinQ❑ 01Mr S or D Fea 2. MATERIAL Totol Squon Faet IGNS ❑ No❑ Y TYDS ElKt. Permif No. S a 3. ILLUMINATION SET BACK FROM PROPERTY UNE N 4 _ 5_ E _ W ^ Zone_ Apprwed,ZOne lnspeetor . (SOacily whicn ie front) ❑ ❑ ❑ ~ I. TVPE soiid1:1 More Than BO% ODen❑ Laos INSPECTION TICKET MATERIAL FENCES 3 SET BACN FROM PROPERTY LINE N _ S_ E _ V JOB 1( ( (Soecitv wnich is front) _ _Q ❑ ~ 0 S ADDRESS i. OTHER 2 13. DRAW SKETCH OFt SHOW BELOW,THE FENCE,SIGN,OR OTHER STRUCTURE,G (SETBACNS OR PROJECTIONS INCUUDED) ~f5 ~a 3 DATE: BLDC. PERMITA U PERMITA BLDG. CONTR. Q J SUBCONTRACTOR DATE INSP. REQ. TYPE OF INSP. "r - "'"-`"INSPECTION MAD~~~ ~ REMARKS STREET NAME SHOW OISTANCES FROM THE M41N BUILDING To-A0J01NING HOUSES, STREETS, DISTANCE TO PROPERTY LINES,NOT MAXIMUM OR AVERAGE DISTANI:E. W R FORM 619 APPLICATION FOR PLUMBING; ELECTRIC THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WOR PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANC ~ ELECTRICAL PERMIT PLUMBING PER STATE IICENSE N0. STATE UCENSE N0. ALUM INUMWIRE UNDER SIZE 8 ILLEGAL FLOOR BSM 15T 2ND 3RD 4TH NQ FUEUCkcMOrn Gai ql Propone EI Solq WATER CIASET FORCED AIR - BTU ~ WASH BOWL HOT WATER - BTU TEMPORARY METER STEAM - 8TU NEW SERVICE - AMPS BATH TUB AIR CONDITIONING-BTU CHANGE SERVICE-AMPS SMOWER LIGHTING SINK OTHER fiARBAGE DISG REFRIGERATqN SYSTEM HEATING WATER HEATER Retri eronf GrouO POWER SUB-QFCUITS Poundt CMr e UTILITV(RANGE,DISPOSER,ETC) AUTO.WASHER AUTOMATIC SPRINKLER SYSTEM FIXTURES DISH WASHER WIRING MOTOFtS 6 CONTROlS FLO(St DRAIN ELEVATOR SIGNS URINAL TRGNSFORMERS 9 RECTFiERS SEWERS ADDITION TO OLD WORK OTHER FIX?URES MOTORS OVER I HP , TOTAL _ . _ i. , ih _ _ l " _ n. . REMARKS PERMIT FEE I hsreby acknowledqn ihat tnis apDlico- a~ tion u conect and understand tnat I USE TAX cannot itart thie Drolntt until Ihia o00li' ~ O~ Cotion if approved. I shall comply with TOTAL FEE Me lows ot the State of Colorado and to . the Zoninp Repulationa ond Buildinq APPROVED c+~*no......,,~n i ~ Code of the City of Wheat RidQe. Any v r~ violation ot tne above rorms wdi cause CHIEF BUILDING N. PECTOR,Cityof Wheat Ridge . immediare ievocotion of tnis vermit Date Issued ~ oolf an Idnmo,• ~ NOT 3-S 3 CALL 234-5833 24 HOURS IN ADVANCE FORINSPECTIONS De& C z 1201/ 2Cqmnp ~•c• 5- ZCIZ/iG' •'33~G/1%c- ° v \L McI ~f 7 G'iZ. 0v=+4t . +~I Pe - zh«P r Hi IY~w ~lu.•-k- ~'yh" ~ s~ c~.;+ 12-FS 3 :~nc,.~e. ~a~.k5 CC.~~....G 1'L.. r2e.LlMlu~!e4 LL.-erz P~ • pJ1TE,ep-Io~J 1%~4 iIZ ~ _ i. _ V 5~4',I ,~~c fj,5~ i s~•l ` c• 1~cc4- ~ - R ~ , L 971 c(,- -Z~f 18~, -70 _ 9 INSPECTION TICKET JOB ~ ADDRESS 1 C9 ~ S W`~~~ yV~ 4 ~ DATE: 3 a BLDG. PERMITtl FJ ~1O PERMITM ' BLDG. CONTR. ~A SUBCONTRACTOR DATE INSP. REQ. -S 3 TYPE OF INSP INSPECTION MADE ~3 O REMARKS 7 _ W.R. FORM 619 J f A ~ $ ~ ~ m n a'o ~ o a n m ~ mm o ~ o_ c g °m ' m ~ a ~ m 3 ~ S 3m m ~ 0m 0 m m v m c x? a m m m f 0 c 0 0 0 m ~ ~ a m ~ \ F 0 a ~ x m 0 ~ f z Q C 9 8 m 1-i (D ct w ~ N 7 O M C rt ~ 07 ~ 0 w iERNR NUYBER M93#18670 s o m r 1 0 m a a ~ a O N Z N 0 1 ~ 0 s 2 z m a J ~ ~ Ln ~ w 00 ct X < ~ m ~ GJ C. w n ~ r 0 ~ N ryr C rt O ~ b O O X rn I N ~ ~ O ~ r m r• ~ n ~ru C+ M,~ 0 0 v ~ o v naO~ ~ w o O IA T O N OD H. 1 O N r n~ p N N (p V O U ~ O ~ m m m O aap~ mm~m m ppm o ac m ~emm n 0 a » c a n - a o a S° a m ~m°n 0mae p 0 mm2 o c mma? m m aq n v S0 om9 p O p m£~ mw3 0 moc o3E "9 a m£m O» ~ e omo a S 0 ~ ~ f n ~ » V ~ 9jf0 o°fn 0 m ~ o m C 9 fl m m° 0 a N D N b b W ~ H H ^I~'1 l l a ► / ~ O ~ z ~ ~ O a . . . „ ~,.p, , _ . . , : . . . ~ _ ~ ~u ~b~~~,~ ~ . v. ..F,~,., , ~a.. , ,w . . , . , . . . . . , , . , . . . ~ , e ~ ~.x,x K , J~w.. ~ ~ _ ~ . ~ , ~ ~ _ r , , , u ~ ~ , , ~ . . , : _ . . : _ , . ~~a, ..v~ a~~.., ~..~~:._r.x .~.~r , ~ ~,~~~.~,~.4, ~_~,a~, ~ ~ ~ . ~r . ~ w~ ~ _ _ . ~ ~ - ~ , , ~ ,~.p:~ms~Nt:,t~,'+K"'-t.•a .~at.~nYb.~v,..:. +r?~. . .xN*.kka#e¢„mr.+~'.R '~`FF~a.~. .s, ~~m;~.a.m„YR. ~v'k+nv.,k•~rxr..NS.::.kn~rvv•rv..v~.rmwanu.,,p.nn;>4H. w rve,naKV✓.. .hs..,2w,wrda+s:'W.t~..:h,,.-a ...n '~+.i39X- , ~ ~ : i . . < „ . .,x a, _ . . , _ . . . . - a , a.:~~> v s .w^ . - . . n~r . ~.r , . ..,m~m ,~..w w~w., y~.y'+«. ~ jyw. . t~ i # ~ , ~ f ~ ~ ~ ~ . ~ M i `~s ~ ~ . . ~ . ~ ~ ~ . = ~ ~ ~ ~ _ ~ ~ . ~ . . ~ ' ~ . . ' . . . ~ . ~ ~ . ~ . ' . r . , . ~ ~a'-~'~' . . ~ ~ , . . ~ t ; , „ ' ~ ` ~ ~ ~ . :°krrt~ . ~ . . . . . ~ . , . ; r , , , ~ tr .,r+- ~..ct~ . ~ . ~ f" r ~~:e ~r ,k[ . . . f N~ ~~Y..~.,rr,=+. _ . $ . . . . r~ . Y y~ T': <'yS~. ~ ~i, k...~~. . ~ ' ~ ~ ~ ; , ~,ro ~ ~ . . , , ~ ; r ~ ~ . . g~~ ~ . ~ ~ ~ ~ F . ~ . _ . . . . . ~ a e ~ . . . ~ ~ , , ~'w? . ~ ~ ~ i ~ t ; ~ ~ ~ a~ 4 4 `=q~ . , . . . ~ . . . ~ . ~ ,_>'rvr . . . . . . : v. mm.. cr«~ a a + . . . ~ ~ . . ~ . ~ . . y~ ^ . ~ . . ~ . . ~ . 6 I ~ ~ , .„~8. x, ~P Fx ~ r ~ k . . ~ . . . ~ } ~ ~`.pa~.. ~ , > ~ r~~ . !'ae'= . 1 ~ ~ ' . . I 4~g~ ~ ~ ~ . ~ ~ ~ . ~ . ~ . . . ~ ~ . ~ . 1 ~ ~ ~e . ~ , . " . . ~ . ~ . . . . . . . . . . . . ~ . . ~ . . . {t~°4~~ ' . ' . 1` f ~r. ~ ~ ~c ~ ~ . L: f "T.. ,~q~f . ~ u t . . { :t` ~ d~ i ~fl' lw:~~ .r r " . . . . . . . . . . . . . . - . . . . , . ~ . ~ ~ . . . . . . . . . y a . ~ ~ ~ . ~ ~ ~ ~ i k~~"~ # ~ S e ~ ~a Rr' S R . . 1 ,~B i . „ ~ k ~ t ~T ~-1 . . . ~ , t,) ~ ~,~p ~ ~ „ ~ . sp A; .;Y ra . i,~„a ~ ~e ~ f . . ~ . . . ~ ~ . . ~`a . . . . . ~ . . . . . . r ~ ~ . . . 5 . ~ ~ + . . , ~ ~ . . . i ~ ~ ~ ~ ; ~ ~ ~ fb. ~a ~ w r, : 1 ► a t ,f ~ ~ F~+ ~ " ~ ' : , qd ~ ~ ~ ~ r :~a~ r } „.3+~ . . ~ .,I, . C ~'~7+"n k , . ~~yn~ +s.".~p~Yj ~.~y~~~`^5 . . ' t` 1 ~ ~ . ° e~'.:a~ i ~ . yy" ~A3 Y~ t° Jk t M~~{"L =h t ~ , , ~ ~ _ . ~ ~ ; ~ . . ~ ~ . . s.. . . f ' , . - . .r . _ . t"~~~ ~m f ~ , t ~ x. ~ qye > ~ :1 . ~ ~ ~ k~: ~ , f ~ _ ~ ~ , E ; y F ~r r: y°~-~ r _ ~r-~. ~n~; ~~k ~y . '4' " S^aw~ -r ,.~M~~' ^ti"4i m„~i ~ ~x~ ~ ` ."'W"sk~iVw§'Td` i r..{f" s w.-:^$ . . . . . . . 4. SY gA . ! . . , . . . . . . ~~j " . f 1' ~ ~ r, , ~ , _ w . ~ ~ . . ' , ~.w=~. . , r, ~q• `~~iy~~,. ~ . . ~ : P~ . . ~ . ~`~,'pyy ,g,gT, . . , ~ , ° „ , ~ ~ ~ ' ~ ~ ; ~ ~ . . a'~e~" .~k ~ . . e ~ , ,V: , a. , ~ ~ Erµ y. . ~ ~ ~ ~ ~ „ ~ ~ , ~ r . ~ ~ ~ ' <.-r. , ~z.«~ , : 4 ~ ~ , ~ ~ P . . S . (f . . , q . . . ` . , . : . . . ~ ~ ^ ~ t Y fi w ,t . . ~ TM' ~ . ~ . . ~ . . . , a ~~s. . . . ~i . - .,.'W . ~ ~ . . . . _ w~u:, .5d ~;tµ~ . . A~. ~ . r . ~ ~ . . : ~ b ~ ~ . ~ . . . ~ ~ . ~ ~ ~ ~ . ~ . . ~ ~ . . . . ~ . , . . . . ~ . ~ ,&N . . ' . ~ . . ~ . ~ ' . ~~p~f . . . . . . ~ . . . . . d*i„wa'T`Y . . ~ - s ~ ~ . . ~ ~ . . - rc~ ~ . kd~ , ~ . . . 3 ~ , . i.~~ ~ ~ . . . I ~ - ~ ~ ~ ~ . . ~ 5 . - ~ ~r` ~ ~ ~ ,.~.,u.~ ' y i W- ~ " ~ , ; ~ , V.,. ~ # F ~ ~o;~ ~ ~ ~ ~ t } ~ ~ , f. ~ f ~ ~ { ~ ; , ~ , ~ ' F ~ ' . ~ `".r . ~ x . , , , , L ~ f, , ~ ~ . - , „ . ~ , _ . R ~ , : - . ~ . . , ~ > - ~ ; x , _,y_ - ~ t r ~ , ~ , , w . . , F , . ~ c ~ ; ~ , , , < ~ . . _ , . , . . . , ~ , ~ , ~m v . , . . x b, , ~ . P . . . ~ ; ~ .t, z-~ ~...fl , ^ ~ . .k . , . . . a _m'o~.ii..,.,. ,~,.e.,.,, +~R~r,am'vwr1;~+ .µm°~._. :&m`~..rrwoa;:..,. a _v:~-i,~.:.-a, ,.~...a~u .:a?4,,.w,y ~ .a ~.^so-, ~ . ,~.->,a;...,~~.,.,.,.ss~•,, ~..m ~ ,ta. , q a . . ,C w!w ~+e~+na~:+{~: ~f. ~ ~3~' t'~ . ::r, , s<r.. t~.:s~. . . . . . ..~~.5 . . . i . , ~ A ~ , . - , . . , ; . ~,,re : a,r>:,. , ,.a„ u~~, . ;a .,h , • : a. , , , . .-0. MM ~ > . „ : ~z . n ~ ~ . ~,e . x..,r~ , F, ~ ~~t~n,.3,~..~, ~ .,N~~»~; ~~,cxi~~~'+e~rt ia~w..n.,~4.M,.~~r,~s~ ~ ,s . . rv.. . f,, .ss~ s~ . .'+'z~^.... . . _ . . . Si ~ . ~t P : _ , ~ , z _ ^ ~;'~y. ~ e . ;»N„ s~ e~-~ ~ ~ „z . • ~ f' ~ , ~'.~l,, , ~ ' ~ , ~ ~ , . . , ~ , a ~ ~ ~ } ~ , ~ ~ ~ . ~ t~ ~ ~ ; ~G : y ~ ~ ~ ~ . ~ . ~s ~ ~ ~ ~r ~ ~ ~ , ~ ~ ~ u ~ ~ ~~.o~,... w. .~.~,,.~.~~R.. oeti.e._~~.v~.~.~ ..~~~.~~,~a~~..~~~ ~ ; ~ r . _ . . s ~ w~.: ~~,.~~~:.~~e~ ~W,~~ ~v. x~~.A~~~:~~: F,N,. . , ~ ~ ,.~;u~ ~ , ~ ~ ~ ~ ~ ~..n ,.a . .~>rt~.-,..xi~a~ . .s, , s,. , . ..M, ~ ~ . M~ , ~.,a < _ ~ ~ ~ ~ ~ , , a ~ x s ' : ~ , ; € , < ° E r , , , ~ , ~ _ ' ~ ` ~ % : ~ - ~ , ~ a , , d ~ _ ~ , - ~ ~ ~ w , ~ ~ ~ . # i ` ! s ~ ; ` ° r i e z # fi , , ' " j ~ ~ k ~ , . ri, ~r ~v,. ~ .w . . „ ~3., r~ , ~ v,,, „ , _.1 ~:W . m~.~~ , h.~.,~, ~:,*~:a ~c., 3 rm n . , ; ~ ~;~~a.7c° u s . : . w . . ~ a , , N, a:.. , . > , ~ ~ _ .~A.. r~ N._..,....~:._ ,~m,~ ~,,.~.~„a.,~~. ~ ~ d ,r~. : a ~ ~ ` ~ , ? ~;r, ' e- . ~ , ro w, • „ w~,,.~,.,~, t~ , ~~.m~,. F.. r~ R ; r ° ~ ~ ' , , ~ ,.~'d , ~ ; . '~,a ,,s v= . 4 . . . ~ ' . , . ~r. ~ , - LL . ~ n ~ ' ~ ~ ~ _ . , ~ ~ ~ , ~ ~ ~ ~ ~ v+ ~ _ ~ . k ~ ~ ,,rr. ~ . . . . . s . . , . . a~ .r . _ - . , y , , ` d ~ . . _ 5, . ~ , . . „v. a . . . . . . . . . . ,F ~ . ~ . . . x:, d . . . 1 . . ..n'"~ . " . 'e ~ . w u : , ~y . ~ - . % . ' n .i ~ . . y . ~ . ~ ' ~ . ~ . . . ~ ..v, " _ ! . ~ ~ ~x a . ~ 1 . . ~ „ ? x,v" ~'331. ^ . , ~ ,p . ~ p e ` m" w~,.m ~ , • . ~r;... ~ ~ . a, . F~'sR~'hb+'~.,•.kA~v2~^,zT" fl`wq'z y~p~ .I~~ a' ~ 1y~~F ~ - r~YNM1N'~dd~PY?w1B~' ^K+wv' 'uBVYiztil. ~~e . .x - .~c ~ .~p-.e¢ : l , ~ 1 . " , '++m.'•rs+R,....v~+rv. -a rnvrz,.-rr,r. w ,v n-e...~...+ ~ ...-n, .c ~ . .v ~ e . ..e, . _ . ~,...*5y. .AroYF tefi+;1S~?Ne°'~r"wrffia'..~ya . ~",i?., ~Y.~y„ . ' ' ~ . . ~ . . 4 ~ i.:,~ . . . . S . . ~ . , , ~ . . k . . ~ . § . ~ , , . i ' . . . ~ . : ~ x ; .r . _ , ~ ~ ~ . _ "~:•i i ; g r s ~ a . : F < ~ ` ' et p ~ , ~ t , , y~+ ~ ; , . , < ~ , ~ , ~ a ~ ~ 7 ~ ~ ~ ~ > p- a ; ~ , ~ ~ ~ ~ . ~ ~ ~ ~ ~ ~ ~ , ~ ; , , ~ ~ ~ ~ ~ H < . ^v., } ~ o ~ ~ . . . . . f . . . . ~ °:.w• . , . . ' Y% . ~ . , ' s " . wEf3+~ aRrv? ` . . . ~ . . . . . ~ .r,..~~~ x,. . . . . ~~d![m!N' nY 41*~a°!' - "iv'.M^^~.wy.r..... . . > . _ . _ . h s rv -~z.,.,-; - ,>.c.r~. ae .~y . . , ~ . - s 3 ' . . x , ~ .2 -a..y . .a.+. ..,re~ A1N~ n.. ~ . avra,i...:•.gaa. +tk~Y.Y..+rir . W ...~t ..a.~ . y..., . y :::n,.'w• .E. a,-w... i~.z^b..~ ~ • - i + . . 4~ »e&..s M rr. ~e-.i e .;..+5..:'znrYH.fi&tV'..t:k:4ffit"s~iw..~e. . . . ~ ~ . . -C Y l..b. A'°x . MnM.. 1 ~'X, ~I . ..t,..., v a . " . . . d~ _ , ~ _ . . ~ - -r =~.,.r~ . ~ . . . . . . ~ ~ ~ ~ ~ • . . `j. . . .C ~ } . . ~ ~ . . . .:'.w, ~ . . y'~~ - . , ; n ~ ~ . ~ ~r „ , ~ ~ ~ ~ ~a „ E . s ~ ° ~ ~ > . ~ ~ " i F , ~ + ; ~ ? ~ ' • .p .J s. .e., ~ ~ . _ y ~ ~ . . . . . a ~ ~ . . . ~ . . . ~ . , Y xarmew.n ~ E' . . . W Y r ~ y... . , IDs . ,..n. g ~ .~""~W {y ' . S c. s m , r.: . , (.ra ~ d. ~a . . , s > A' ~ e. ' " ' ~S- . . 4 ~ i . : . e r^ - . . ~ ~ ~ ~ ' . ¢ . . . . . . _ ~ ' : ; . . ~ ~ae:., ~M . . ~ - . . .a: . . ~ uri,'s ~ . .¢~:a, ti .we+.z~ s.,r~ .....+e~.~s. ,a ..r...,..;v,. wr.w~,m:as:..+.~- ~w.~< ~ ..«.ta,.:aMrnv, .uu „ , w: .>m ,c~..;... k , . .f.!;,.:?ri~:~i„k . 3 . . : . 4*u" kbu.vfi. . w. ....^w . . '~Ya`5~' , , , ~ . . . . ; - ~ • .zg~b•y , ° ~ ~ . . w . . . . . : o ~ i y.w. . ~ ~ . ~ » . . .'o-: ~ _ ~ , 5 ~ ~ r : r z - . ' ~ ~ . , v , . . . ~ . : .u ~ . ~ 'u ~ w . : , ` i s ? ~ „ , . . . . w r . . : s . . ~ v , . ~ ' ~ . . " ' ° ; ~ . ~5 ~ ~ s ~ . ~ , T. , A ~ ' * _ . y. ~ . . ~ . _ ' . , r . i n ` x}` . . : ' . . ' . s..~ ~ x . . r ~ . . . . ~ . . . ~ ~ v. . ~ . , . , , . . g~. a . . . ~ T. ~ ~ ~ ,e. . ~ . ~ , . ~ .ro, ~ y,.~1.r'i v^'-~r : , ; , ~ - . a . . . ~ . . ~ . , ~ ~ . ~ . t ~ ~ ~S. . „ ~ . _ , s , y~ ~ . . , , . . . . ~ . . r. . . . ~ , , x . . ~ r . . . . - , g . . - " w~~~. " ~ . . ~,..s . . . ~ A ~ ~ . . . . . ~ . k , ~ _ , ; . . - . ' ~ . . . . ~y. . . . ~ . ' ~ . , ~ , . , . ~ r~ . . . . ~ '~.x , .e> _ ~ ~ ~ . . . . . . ~ . . . . . ~ . . . . ~ . ~ . ~ . .H ~ .s . , .a ' ~ . ~ . r Y . . . . : . ~ , , , . ~ ~ . > : , . . . a,.~ -~.,>,N.~.......w..m..... ' ;.ar .Nbtwng afiM$~T' mtl9re*w~`~ ~ i . r,...,.,. .g ~~~~y~sq4::, r.:~~ n'fn . . . .e . . . ~ , , . . . . ~ . ~ a a ~ . . . r..~. , A'r"°.. ~;,a~"~s- se.~E~~ . , ~ ~_,~+s+.~..~ . . . .anit:w!c~~ ..~.~,r ~ , t :rn.s-a~a~~.:°~ n „ ,v.:~.~..a .,;s, ~a" _ _ ~ . .wt.. ~y4 . ..:.~.ae~ ~~,.z...,.. r ~~,bw = , .y,., . ~,.".i: ° ,t ~ . . , . . . . . . 3~' . . . . . . . , z~::P w!yqai x . .v~ t~ . ,ti,.°"a,efT&~v . ~ A~ ~ a~..x . ..n~.:~.K' ~.{aR'ros~v;;St~~.?i~,.g''~'~s>'~~E..x~ . .3"e . . . . . ~ . ~ c . ~.,...5 ~ _C"+~~ ~h . . . ° . ~ <uC~ x . ~ e~ . _ i . . J•' . !F . } ~ . . . . , ~ , . . ~ . . . . ~ ~ ~ . ~ . . . ~ ' ~ . ~ . . ~ ~ . . . . . . « ' ~ . . . „ . P, ~ . ~ } ` ~ , t = 5 .~~~r u. . . ~ k . . . . . . ^ ou~.n+. <s.vr ~ n ug= a. , . . . . . . ' . . . ~ t . ~ 4 . . . ~ . . . ~ . ~ ~ ~ j y5 ~ ~ • ~ . ~ ~ ~ : . . . . ` ~ ~ . . ~ . ~ , . . i:. . . r : 7 . . ~ a . . . . . . . . , . ~ . . w . . - . . . . ~ ~ b.~•- ~a - ~--,~,w;~~. ~.q..„ - . . . ~ . . . . . . . ~ . ~ . _ . . . . . . . , i ' . . , t . . ~ . . . .,r" . . , . . . . . . ~ . . . . . . . . . " ' ~ ~ ° . . " ~ . ~ . . ~ ~ ~ . ~ . . . . . . , . a ~ , ~i . . . ~ ~ ~ ~ , ~ . a ' . H ~ i t " . . . . . . ~ . . , . . ` ~ ~ . > . 1 ~ . . . . . . . ~ . .A.~ e.,.e . .,r F : . ~ ' , ~ ~ ' ' - ~ . . `s3"aar.:*.~%h.,.~.: . , . . , , . s: ~.w.r~ . .r-,~ ~.r~ :..,,.....w~~-.. ~ ,b. ~ ~,~'KA.:.H.iv'.~m~`Jn~..F~q r ~e.,..~,,., e2P3x'~ # v p~ _ . . ~ , z~..: ...a, a ~a+n„~-,..~.~::.~..:..at~.~ ._~~.,.va..~«s,,,x ..xa,a y+ 'r~, ..,+iosx oww~, . aw,n..:w.,.+.,a~.. > r+rw~" , th . ~ . . . . - . ~ > ~n . , ~ , ' . , , r ~ , , , , . ~ sa w.~ .o~„.,-.. ,~+~',anmx„r ~ r mYw.s,.~ .+~ck.~4,ss. ~ ,av~sq„.~. am~. xi:,'k~',~ . , - w~a-.~-: . . , ~7'- ~ . : - . x . , ~ . ' . > . . . ~ ,5. ~ ~ ~ ~ ~ ~ . . i . . . , , . , ~ ~ ~a, - ~ ~ ~ a , > ' ~ ~ ~ ~ ; ~ ~ , = d ~ . A ~ ; ~ ; , ~ c ~ ~ , r2 ~ , '~.u., ~:.r~' < , 'vr. . ~ y ; ~ ~M ~ : ~ 6 ~ ~ ~ x y~ _ ~ . ~ ~ ~ ~ , ~ . ; , ,f ° ; . ~ ; ' ~ ~ ~ ~ # " ~ . U ~ ~ - , ` ~ : ~ ; ; , „ . ~ ~ . x. % , • : , ; , ~ ~ ~ . , F . , . ; , ~ ; . . ~ ~ , ~ ~ ~ e ; ~ _J . ~ ~ ~ ~ . , ~ ~ rr pf , ~ . r - , ~ < ~ - , , ~ ~ ~ . K , ; ~ , P , r. ~ , ~ ~ - , s _ - u ~ ,=a r,~ ~..,h...~. ~x~ _ _ r ~ ~ .~,..o a....~ , 4 , , ~,:n.., 4- § ~ , ,M . _ ~ . ~~a+~~r~s~:~~~ ~ ~ q~ , ~ ; . ~ , = , 4 . . . . y , . ~ ~ ~ . . ~ ~'4 W . ~4 ` ~ . . - ~ ~ ~ ~ . c.. . ~ ..`~'"~r , ~'3:., . ' ' ` " , ~ . a~ . n ~ . 1 . . , : : - , . . . ~ . . . ~ a t-- , ~ . . - r ' . S. . ~ . . , ~ ' ~ ~ ; , ~ ~ = . .,,a ~ ~ ~ ` : ~ i'- ~ . ~ ~ . : . ~ ~ ~ ~ ~ ~ ~ ~ ~ t_ . ~ ~ ~ ~ a ~ ` ~ a ~ _ _ , . ~ . ` . ~ ~ ` . . . , ~ . ~ ~ -9 . ~ , . . ~ ' ~ r,.~'° . ! ~ , ~ ~ ~ ~ . . : ~ . = , ~ - ~ o-~ . r . . , ~ . . . ~ P . , . . . . . . . . „ . . tt ~ r*. . b ..~.t, ~ . . . ,F . f` e'°i.. . , . . . ~n ~ t ,r. , A . ~ J . ~ . ~~~~n. i~ ~ ~ ~ ~ , s, F d~ ~ ~ : ~ . -~i d . ~e . . , . . . ! ~ . ~ ; ~ ~ . . ~ b ~ , . g_ ~ , i a~~'~ . ~ S r ' _ T . ~ - ~ . . a'.~ . ~ . ~ . ' : . ' r,nor .S n • ~'o ~ , .t'...+ - .x. > ~ ~z Prr*~.~..s+y~. ~ . ~ , . . " . . ' . ~ ....n.r, , ~ , n . ,a . , ~ , _ . ; , e..:~. . ry~.'.~ ^:~1F .P:eF, .+4.v , ~.::a, ~':~39 , .,.:,R;.. a.,•~ ~ `=~S.~BwVHC:.s+...~ ` 'km~.~~-iw w~v..x ,+,i::- ..n*.~~a:',wiN., rtus, ea,-...,. . . w . . . . . ":~Z . . . . ~ma~ . » - . 'C~ ~ ' ° . , c . . . . ; . ,i4 , ~ - _ . . . _ , ~ . ~ . . . . ~iv ~ i, . ~~e. ~,~✓5~ . . . ~ ~ . . . ' ~ . . . . a ~ . . ~ i,, . , y, z ~ ~ ~ ~ , . ~ ~,~:P ~ ~ , ,w. ~y,a»,,,. ' t , ; : - . ~ t , . . ' . . ' ~w~»~ . , . ~ ~ ,t . . , ~ . . . ~ . ~ , . ~ ` . s ~ ~ ~ ~ . . 3~ r' , , ~.i . ~ ~ ~ , ~ ~ , e . ~ . . ~ . . ~v ~ Y : ' . , ~ . . . ~ . . . . m> , . N . . . ~ , ~ , . , . e ~ > s . ~ ~ . ~ ~ . ~ - ~ . ~ . , . " € ~ ; ' • r ~ ~ ~ - : . . . , . . . ~ ~ r . . . . . . ; ~ . ~ . , w y ~ _ ~ d , ; < , < s .e.M.~~, : F ~ ,s . ~ , , ~ C ~,,~...v ~ ~ _ ° ' ~ ~ ° ~ ' :x~~~', ; , ~ ' ~ ° " : . ..w..- . . ~ ~ w ~ . ~-.:F,.~.._ x.~. ~ . > ~w,yry+w.y ^ ~ . ~a~ ~ . . . . , '.~cw+~`~r.a~sr»a*sa~.P.:.a*a,.~.,,...~..,xata~.s~~+:~d~l~k.. '4^~~ . ; ; . iTa.=~e. as,~1~' +~"~`vf~.afi..,~ ...,Yr«-,.:. ..M~t _--.:+r _ . a _ ~n-~*~a`.., P:.-^!„3+PoA.wt9~.taE.. ....d.x ..r~..r~'?M1"~'.~+ . ~k. =~9. ,'~k'.msti,•w-mf,: g 2. ~ _ , , y, , ~ . . . ~ + . , - ~ ~ ' . . ~ . . ~ . ~ p . . ~ ~ k ~ . ~ . . I . . . . ~h . p . _ . t . s . , & . . ~ : _ . . ~ . ; . ~ " ~ ~ ~ i. ~ ~ ' ~ F " . . ~ i ~t~~.. S P ~ e . . ~ _ t ~ ~ ~ . ;t : ~ ~ ~ i ~ ~ . ' ~ ' i ~ ~ : v' , , a r . . ° ~ ~ ~y p . . : . . < . - x , ~ ' • . a~~ . ~ y~ ; . ~ ~ . , . ~ . . d. , . ; ~ V~k r . . ~ ~ ~ ~ ~ . ~ . . ~ ~ - d . ~ . . . . . . 4k , y ~ . , x. ~ ~ ` , b # , ~ _ ' ; ^ ' ° . . ~ ~ ~ f , „ . . ~ ~ - . , ._s ~ . " ~ . ~ . . . ~ „x; . ~ ~ . ~ . . . " ~ . ~ v r ' x.., . ~ , . . . 13 , > ~ ~ p ~ APPRO , : . ~ ~ ~ ~ ,.,;...m ~ : : r., . ' ..;~a.re.-m, s. ~ ~ ~ - . . y,... , ~~.:k r. . ~v :tia?+,:5~r~•ti~sa-,~ ,s, s~ ~:.n~~.~ .,~+y~s"q'..sa~~, .~M , at 'c.,::,~~.e.z~.,~w+.:::`.s.a - ' ~~twh+M .~.~~~+~~r~'~..~ne.mg~,;8~r1.,. ~ ¢5~, .fb... .~~d . . , ..ty,~~~ ._-~.w . ~.,,.~...,°rsrt~a. , . . ~~mn, . . _.~.w r,e~.~ . _ . 7'~:~.-- .;r : ~ _ . ~ . . ~1:~' ~ = . , . . . . . . . ~ . ~ t ~i o . ~ . . . ~ ~ - ~ ~ ~y~..~ . . ~ . . . ~ ~ ~ ~ . . ~ . . . ~ . . . . .w.~ ~ , . . ~ „ . . . . . f. , ~,3, vF~~.T?~ • ev«. , .ew. ~ ~ . . . , , , b,. ~mr+ 3~...~, , . ~ r „3t~ ",rb fi:^.~` . . . . , . . . , . .rz ~ , f . , , , . , , ,d , ; ~ r , . ~ a . ~,.w~.~ . . , .+rm-~..,.~~d~..4.~.as ~ -,.r. ;::q:.,. , . . H~.n:+.;.- . , - , . . . r . . - , r . . _ . . . . , . . . . . . . . . . . ~ . . ~ ~ . . ~ ~ . ; . . . . ~ . ~ . ~ . y~~ i. . ~ . , . . . . . ' . , . . ~ . - T::.:. . ~19 n 8~ ~ . . . . . . . . . . . . . . . . ~ . . ~ ~ . . . . . ~ ~ . . . . ~ ~ ~ . , . . . ~ ~ . . ' ~ ~ . . . ~ . . . . . . , . . . . . ~ . . ~ . . . . ~ . . . . . . . . . . . , ~i... ~ . . . . . t: . . ~ ~ . . . ~ ~ . „ . , . Y. . . . . . ~ . , . ~ . ~ . . . , k F. . . ~ . . . ~ . ~ ~ . . . . , ~ . . . ~ " ~ ~ ~ . . . . ~ . ~ . . . ~ . , : . . . . . ~ . ~ . . ~ ~ ' ~ . . , . . . . . . ~ ~ . ; , . . ~ . , . . . . . . . . ~ . ~ ~ ~ . . . . . . ~ ~ . . k . . . . . ~ ~ . . . ~ } . . ~ . . ~ ' . ~ . ~ ~ ~ ~ . . ~ ' . . ~ ~ ~ ~ . . . . . . . . ~ ~ . . . . . . , . . . , . . ~ . _ . . . ~ - ~ ~ . ~ . - . . . . . ~ ~ . . . . ~ . . . . . . . . . . . ~ ~ . . . ~ . . ~ ~ ~ . - . , . ' . . . . . ~ . . ~ . . . . . ~ , . . ~ ~ ~ - ~ " ~ . . . . . . . . . . . . . ~"v~`~~.'~4 . , ~ ~ ~ . , . . . . . . . . ~'e:,~~ : . . ~ ~ . . . ~ . . ~ .p ~ . ~ . . ' . . . - . . . Y . . . . . ~ . . . . . . . . . . . . ; . ~ . . . . ~ . . ~ ~ . . . . . . ~ . ~ ~ . ~ . . . . . . . . ~ . . ~ ' ~ . . ~ . . . ~ ~ . . . . . . ~ ~ . . ~ . . ~ . . . ' . ~ . . . . ~ . . . . , . . . . . . . . . . ' . . . . . ' . . ' s. . ~ ~ ~ ~ . ' . . . . ~ . . . . . . . . . . . , ~ . kkr... ~ . ' . . ~ . ~ . , . . ~ - . . . : . . . . ~ ~ . ~ ~ ~ , . ~ ~ . . . . . . . ~ . ~ C . .i ~ . . . . . . . . . . . . . ~ ~ ~ . ~ . - . . . ~ . . ~ . . . ~ ~ . ~ ~ ' ~ ~ .3 ~ . . . . . . ~ . ' . ~ . " ~ . . . . . . . . p . . . . . . . . ~ . . ~ . . . . . . . , , . . . . . . . . . . . . ~ . ~ . . ~ . ~ - ~ . . ~ . , . . . ~ ~ . . . . . . ~ ' ~ . . . . . . . . , . ~ . ~ . . . . . . ~ . ~ . ~ . ~ . . ~ . . ~ . . . . . . 3 . ~ . . ~ ~ . . . . . ~ ~ ~ . . ~ . . . . . . . . ~ - ~ ; . . . . . ~ ~ ~ . . . . . . ~ . , . . ~ . . . . . ~ . . . . . ~ . ~ . . . ~ . . ~ . . . . . . ..i . . . . ~ ~ ~ ~ . . . . . ~ ~ . . . . . . , . . . . . . . . p~ . . . . . . . . ' . . ~ . ~ . . . . ~ ~ ~ ~ ~ . . . . ~ ~ . . . ~ ~ . . ~ . . ' ~ ~ ~ ~ ~ . ~ . . . ~ . ~ ~ ~ „ . ~ . . ~ ~ . " ~ . . . , . ~ . ~ ~ ~ ~ . . . . . . . . . . , . ' . ~ . ~ . . . . . . ; . . ~ . . . . . ~ ~ . - ~ ~ . . . . . . . . . . . ~ . . . . . ~ ~ . ~ . . . ~ ~ ~ . . . . . . . . . . r . w . ~ . . . , . . . . _ . ~ ~ ' . ' ~ ~ . . ' ~ : - . . . . . . . ` ~ . . . , . ~ . . ~ _ . . . . . , ~ . . ~ . . ~ . . ~ ~ ~ . ~ . ~ ~ , . - ' . . . ~ . ~ . . . . , . ~ . . . . . ' , , , . . ~ . . . ' ~ ~ . . . . . . ~ . ~ . . . . ' . . . . . , . ~ ~ . ~ . . ~ " . ' . . . . . . . . . . . . . . . . . , ~ . ~ . ~ . , . . . . . . . . . . ~ ~ . . ~ . . . . . . . . . . . . . . . ~ . . ~ . R . . . ~ . : . : ~ a ' u, ..:.,w r. i S: . . . ~n.. . , . .r ~ , . ..s « r r.'u. ...rv.. re,...,..r. w s , ..~F , . , ir »s~:'rv r.v,...;~,.o-... iers', .:,:rt".-s >.s :~.,v ` .m...t..,.:nw n.d8w.~. . .u .4s...e. ,e ?nrn u,s~s,a ..~„me..w.w .-~!w°'.tije'u tvn ak Ymu ,EH....m. . ~ . .v<~ v ....3. ..+H . ~:!~:~k . .ik~„ . . . 2d n. . .....r."F.t.,.a.. •"u `.W . . ktd :s .•.ert~~ F `m,~'?.~qy+ o. ~,A.~ . .e««wm*' ~ . m.Yw"'ee"s~?~=ai.n k M ~ . _ . . bF4, w sP r. . ss'r.. , tk i . . . . ~ . a _ . . ~ . ~ . . . _ a~ , ~ ,.yr. ~ u,~v~.r„wa~~.en};~t~,.p,w~K,~~~,r,sGm~s.,~+~rr~,~a,a~~-m%ac'~,-~~.+.`~a~wt:.*a~ w~; „a~.a'':~v; . ~ . ~ ~ . . , _ , . . . ~ . . . . ~ ~ , ~ - - a~e ~ . , . ~ . ~ . ~ . , . . . ~ . . . . . , a~:.. E , , ~ n, r ~ . , ~ . , , , . , ~ . . , , . . W . , , . . . , , . . _ . . . . . F r~ , ,y~ # _ ~ , . . r; ; - - ~ ~ ~ . +A ~ ~R~ ~ v ' . ~ . . . ~ . . . . . ~ ~ , . ' ~ . . ; . . _ . . . . ~ , . . M . ~ . . ~ . . . ~ n , - . ; . _ ~ ` ' ; ~ . ~ : ~ ~ = e - ~ - . ~ ~ . . ' ~ - ' - . . _.o - , ~ - . . ' , , _ . . _ . , , i ~ ~ ~,r;_..... i.~~..._.. , ' , ,.x, ~ , , , ~ , ~ . , . . . . . . ~ . „ , . . . ~ ~ . . . . ~ . w~ o~ wCD N 7 w0 'p O ~ IW o W O 7 N S < N Q (D N 7 N a m y 0 0 ~ ~ , ( 3 N m \ V ~ 0 3 K ~ C- 0 ~ a a N N n 0 ~ C 1 0 ~ Z ~ . ~ Q ~ n o' v 0 - N(D wz G m ~ , • ~ r O a z (n (D y ~ ~ C 0 o rqL L m Z 0 5i v City of Wheat Ridge Commercial Demolitio JOB Owner 9c :.'..~.~.r~ * * Px+RC ZONE CQ ~SUBDItTt FEB nemal, * * T07.+, ~..i COfI1tt19RCf ' Triple i 1 hereby t orflinancei meaeurem@z' applacatEt app~ Signature~r 1. 1Rlie pe State 4 070472 ~,S9b7615 W. 38th Ave#B-101 Tnterior Demolition. ;f 7ACTS . 284-2521Scott Burcham NFO UA • 0343 PERMIT - 070472 ; issusD: 05/22%2007 EXPIRES: 11/18/2007 - Rocky Mtn. Fopk 07-0084 Colorado'InteriorFia: USE: UA BLOCK/LOT#: 0/ ESTIMATED PROJECT VALUATION: ,{~:.p i Fee FEES . w 150.00 31.50 150.00 due to demolition being done w/out permit. `y tha[ the eetback dietances proposed by thie permit application are accurate, and dc npt v1ol8te app: lbe oa segulatione of the City of wheat Aidge or covenante, eaeement,j tawn; and allegatione made axe accurate; that I e or ree[rictione oi becpiy; {p;t ; have read and agree to abide by all conditibay prlelted. "tliat I a9eume fu:ll seeponaibility for compliance vith the Wheat Ridge Building Code and ayy~i t ge Ordinancee, for wo pexmit. Plane eubject to field inapection. qtrac[or/owner . aate . ' . Wpe 3eeited in accordance with the provieione eet forth in your application aM ie ~ypj4ct tp T,hg lgiyq'. C~rado anfl [o the Zoning Regulatlone and Building Gbdee of Wheat Ridge, Colorado oz'~y othns apy,21CaL1R'~, -t.ErP [heCity. Z' Thia P"i~~ahaSlexpire 180 daye from the ieeue date. Re daCe ~4r,ya` tbnelon ma be Y~+eete for an exteneion muet be zeceivM'ptiot to ezpixaYjd 3.IY thig h~Y 9ranted at the diecretion of the euilding Official. k mcpires,a new pezmit may be acquirea for a fee of one-half the amount noxmally requitpd, p=pYittec4 qp~. changea bgsn or will ba made in the original plane and epecificatione and any euepeneion or . eXCeedCb. year, If cluagea have been or if euepeneion or abax~denment exceede one (1) ~~~np-~ be paSO e new permit. 3'pas. Pul; -feeb.ehnll 4 . Nnwork o tF'Jj¢~ maMer ehall bedone Chat will change the natural flow of water caueing a draina e 5•Con[racCp~ ~(llnotify CheHUilding Inepector twentYfour (24) houra in advance foz all inepect;oxufobsema. . writteA ` V61: on inB ' ,~i pection card before pzoceeding with eucceaeive phaeea oF the job. ~°~21 =eCeSi 6. The iat q permit or tTe approval of drawinge and epecificatione ehall not be conetruedtobG g pdyydk E6z, ~ . an ~:`,~it. y olation of the provieione of the building codee or any other ordinance, lav,'yiaQ bf ragulaCiakj ct to field inepec[SOne. Psy Signature of, € puilfling offical date' klEQUESTS~~gB~EHY 3PM3)234-5933 DAYIFORNINSPECTION (THE303)235-2855 FOLLOWIN(3 ,BtTSIt*SS L1Ay I .F. . . COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: oF w"E°r~ gUILDING INSPECTION LINE - 303-234-5933 Date: ~ a CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 -(303-235-2855) PLAN # MINQR .4F"FLICATIQN Property Owner:. (6Cq-)" /AG' fddf ~rTil~Y'° . Property Address: 7~/s- U/ Phone: ContractocLicenseNo.: 0'7rDyY / Company: C6,4✓A'It" -~i1~~/ym~' ~i✓l/1G~ f Phone:7J-0-f~5-~f6,6~ OWNER/CONTRACTOR SIGNA7URE OF UNDERSTANDING AND AGREEMENT Buildinq Dept. Valuation Figure: $ I hereby certi(y that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easementsor restrictions of record; ihatall measuremenls shown, and allegations made are accurate; that I have read and agree to abide by all condidons printed on this application and that I assume full responsibilily for compliancewith the W heat Ridge Building Code (I.B.C) and all other applicatile W hea[ Ridge Ordinances, for work under this permit Plans subject to field inspection. (OWNER)(GONTRACTOR):SIGNED OATE (OWNER)(CONTRACTOR)'PRINTED Use of Space (description): Description of work: Sq. Ft. added Permit Fee:$ Plan Review Fee:$ Use Taac:$ Total:$ Expiration Date: Expiration Date: Expiration Date: Approval: ApprovaC ApprovaL (1) This permit was issued in accordance with the provisions sel foKh in your applicalion and is subject to the laws of the Slate of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of lhe City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building autborized is suspended or abandoned for a period of 180 days. - (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the originai plans and specifications and any suspension or abandonmenl has not exceeded one (1) year. It changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural Flow of waler causing a drainage problem. (5) Contractor shall notify the Building Inspector lwenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifcations shall not be construed lo be a permit for, noran approval ot, any violation of the provisions of the building codes or any other ordinance, law, rWe or regWation. All plan review is subject to field inspections. Chief Building Official Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: INSPECTION R CORD INSPECTION REQUEST LINE: (303) 234-59. Occoancy/Type Inspections will not be performed unless this card is posted on thy. ,rice. (ran the incnection reauest line before 11:59 p.m. to receive an inspection the following ;)usiness day.** Inspector Must Sign ALL Spaces pertinent to this project Date Inspector Comments Foundation Inspections Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Inspector Comments Underground/Slab Inspections Date Initials Electrical Sewer Service Plumbing Approval Of The Above Ins Do Not Cover Underground or Below/in-Slab ectoWork Prior To Date Comments Rough Inspections Initials Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Date Inspector Final Inspections Initials Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Comments ons Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection pistrict for your project. J Final Building I I NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. **For Inspection Time Window — Please email insptimerequest@ci.wheatridge.co.us by 8.00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From Th C of Wheat Ridge omr tercial Sign PERMIT - 201700473 PERMIT N0: 473 JOB ADDRESS: 15 :J 38th AVE UNIT B101 EXPISSUED: 04/07/2017 JOB DESCRIPTION: Fabricate one new 91.65 sq ft illuminated lRreplacement4sign201for west elevation *** CONTACTS *** OWNER DPC DEVELOPMENT COMPANY SUB (303)726-5015 Curt Marcolina 110193 CDM Signs *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 333 / USE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,652.00 Total Valuation FEES Plan Review Fee 0.00 Use Tax 132.80 Permit Fee 173.74 ** TOTAL204.30 ** 510.84 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. myy signaturedo hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized �y the legal owne�}x of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with his�ppermrt. I furhher attest that l am legally authorized to include all entities named within this document as parties to the work to be �ertormed aaln at all wor to erformed is disclosed in this document and/or its' accompanying approved plans and specifications. signature of P WNER or CONTRACTOR (Circle one) Date This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This permit shall expire of days after the date ns issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of the more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and rocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offcial and is not guaranteed. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific a The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, an violation of any provision of any applicable code or y ordinance_egula 'off this jurisdiction. Approval of work is subject to f eld inspection. gnature of Chief Building Official Date QUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. spection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us tween 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. i` F E ow s