Loading...
HomeMy WebLinkAbout4120 Balsam Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: i --j Job Address:` '; 4 Permit Number:a ❑ No one available for inspection; -Time,_ AMM M Re -Inspection required: YeF No when corrections have been made, schedule for re -inspection online at: http://www.ci.wheatridge.co.us inspection Date: ,_ 3 -r72- Inspector: �a. DO NOT REMOVE THIS NOTICE � ► � i City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202002371 PERMIT NO: 202002371 ISSUED: 11/16/2020 JOB ADDRESS: 4120 Balsam St EXPIRES: 11/16/2021 JOB DESCRIPTION: Installing a 60k BTU, 97% gas furnace in basement. **REVISION: Installing 2 ton, 18 seer A/C in backyard. *** CONTACTS *** OWNER (303) 725-5812 STORCK MARIANN SUB (303)945-4319 BRYAN LEITCH 110188 COMFORT PROS OF COLORADO SUB ( 3 03) 841-1032 MACKENZIE MATTEY 018273 PINE VALLEY ELECTRIC, INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 15,000.00 FEES A/C Replacement 60.00 Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 315.00 ** TOTAL ** 415.00 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* � � i City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202002371 PERMIT NO: 202002371 ISSUED: 11/16/2020 JOB ADDRESS: 4120 Balsam St EXPIRES: 11/16/2021 JOB DESCRIPTION: Installing a 60k BTU, 97% gas furnace in basement. **REVISION: Installing 2 ton, 18 seer A/C in backyard. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Air Conditioner/Evaporative Cooler Permit Application Date: Tuesday, November 17, 2020 8:59:40 AM Air Conditioner/Evaporative Cooler Permit Application This application is exclusively for AIR CONDITIONER OR EVAPORATIVE COOLER. YOU MUST ATTACH THE ELECTRONIC PAYMENT FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Is this a new install or New Unit Installation replacement for an existing AC unit? Is this Residential or Residential Commercial? Property Address 4120 Balsam St Wheat Ridge, CO 80033 Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Mariann Storck (303) 725-5812 Property Owner Email mstorck4l20@gmail.com Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Wheat Ridae Payment Form.odf CONTRACTOR INFORMATION Contractor Business Comfort Pros of Colorado Name Contractor's License 110188 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-945-4319 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email office@comfortpros.net Address Retype Contractor office@comfortpros.net Email Address DESCRIPTION OF WORK What type of Air Conditioner replacement unit are you installing? How many tons is the Z unit? For AC - what is the 18 SEER? For Evaporative Coolers, what is the CFMs? Where is the unit backyard located (for example, rooftop, backyard on ground etc)? Is electrical needed for Yes re -hook? Provide Electrical 5690 Contractor's Wheat Ridge License No. Project Value (contract 7500 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Hillary Leitch Permit Email not displaying correctly? View it in your browser. City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202002371 PERMIT NO: 202002371 ISSUED: 11/16/2020 JOB ADDRESS: 4120 Balsam St EXPIRES: 11/16/2021 JOB DESCRIPTION: Installing a 60k BTU, 97% gas furnace in basement. *** CONTACTS *** OWNER (303) 725-5812 STORCK MARIANN SUB (303)945-4319 BRYAN LEITCH 110188 COMFORT PROS OF COLORADO *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 71500.00 FEES Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 157.50 ** TOTAL ** 197.50 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. Furnace Replacement PERMIT - 202002371 202002371 4120 Balsam St ISSUED: 11/16/2020 EXPIRES: 11/16/2021 Installing a 60k BTU, 97% gas furnace in basement. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dina Kemp From: no-reply@ci.wheatridge.co. us Sent: Monday, November 16, 2020 9:40 AM To: CommDev Permits Subject: Online Form Submittal: Furnace/Boiler Replacement Permit Application Categories: Dina Furnace/Boiler Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or BOILER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement residential furnace or boiler like for like? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 4120 Balsam St Wheat Ridge, CO 80033 Property Owner Name Mariann Storck Property Owner Phone (303) 725-5812 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email mstorck4120@gmail.com Address Attach City of Wheat Wheat Ridge Payment Form.pdf Ridge Electronic Payment Form - **DO NOT ATTACH A PICTURE OF A CREDIT CARD* 1 CONTRACTOR INFORMATION Contractor Business Comfort Pros of Colorado Name Contractor's License 110188 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-945-4319 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address office@comfortpros.net Retype Contractor Email office@comfortpros.net Address DESCRIPTION OF WORK What type ofunit is being Furnace, Boiler installed? Number of BTUs 60,000 What is the efficiency 97% (%) of the unit? Is the unit GAS or Gas ELECTRIC? Where is the furnace or Basement boiler located (for example, basement, crawlspace, etc)? Project Value (contract 7500 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit N issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Hillary Leitch Permit Email not displaying correctly? View it in your browser. 1 z; A i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F Job Address: U S�yf Permit Number: c JG' ❑ No one available for inspection . ime I.� , IN/PM Re -Inspection required: Yes �/No When corrections have been made, call for re -inspection at 303-2 4-5933 � l � Date: Inspector: (beri DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGI Building Inspection Divisio (303) 234-5933 Inspection i (303) 235-2855 Office • (303) 237-89� INSPECTION NOTICE Inspection Type: ! �% Job Address: -// 2 y / I� L SAM C J -- Permit Number: 2. ©1/'7 a ❑ No one available for inspection: Time )a, � AM �- Re -Inspection required: (IYes No * When corrections have been made, call for re -inspection at 303-234-5933 �. Date: ;"_/CYf✓/ Inspector: � r DO NOT REMOVE THISVNOTI E City of Wheat Ridge Residential Roofing PERMIT - 201701573 PERMIT NO: 201701573 ISSUED: 06/06/2017 JOB ADDRESS: 4120 Balsam ST EXPIRES: 06/06/2018 JOB DESCRIPTION: Redeck and reoof with Tamko Dimensional shingles - 28.88 squares *** CONTACTS *** OWNER (303)725-5812 STORCK MARIANN SUB (303)842-8484 Gerald Nunes & Perfecto Aragon 170171 Colorado Builders Corp. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,422.16 FEES Total Valuation 0.00 Use Tax 155.87 Permit Fee 172.60 ** TOTAL ** 328.47 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer&erms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Roofing PERMIT - 201701573 201701573 ISSUED: 06/06/2017 4120 Balsam ST EXPIRES: 06/06/2018 Redeck and reoof with Tamko Dimensional shingles - 28.88 squares I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all�oTk to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNYR or CONTRAGTORl(Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code"or a' y ordinance-m.gul n 'f this jurisdiction. Approval of work is subject to field inspection. tits Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. ` - City of WI l6atCc_ COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits@ci.wheatridge.co.us FOR OFFICE USE ONLY Date: 1 6 Plan/Permit #ao � � l 5� l Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: l.3Ase-ln �>K% Property Owner (please print): A& I -,'&n o S'Xo c k Phone: 22 Property Owner Email: All .5 6 /- e � c 0 C c n44 C w Al" 11'� Mailing Address: (if different than property address) Address City, State, Zip: ArchitectlEngineer: �✓��9 Architect/Engineer E-mail:Az %'7 Phone: Contractor: U � lei G 666 6 1'1,511e,'- s C, 0. /0 1-71 Contractors City License #: 171 Phone: 3D5 - 2- - SVE Z Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # t&/fF Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL � RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION a RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION 11 -WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of maaten Is to be used, e ) _ Cr\:Qbe- c- Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (APHORIZED REPRES6 PRINT NAME: s ? ' / 116W e 7 ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer. PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ® Received ❑ Not Required Sanitation District ® Received ❑ Not Required of (OWNER) (CONTRACTOR) i e^; ? DATE OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: SPRINKLERED: OCCUPANT LOAD: r�Building Division Valuation: ; (11111 i i . A' CITY OF WHEAT RIDGE _1�9r®Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: in t P -.S ' 1 Job Address: 1-4 a 1 s 4r,.V'. G (- Permit Number: / S -7 NEC ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No * When corrections have been made, calf for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE Wrmd'j e. -w e-ol (.(-J- 8'C_ F OFFICE E USF ONLY City Ute gate: ceilding 81nspection Services Division 7500 W. 29P Ave., Wheat Ridge, CO 80033 Marr Review Office: 03-285-2855 * ex: 3013-237-8929 Inspection Line: 303-234-5933 Email: ermifs i.reatid e.cc, Building r it Application Please complete all highlightedams on both sides of this fbnn. Incomplete aWlications may not be processed. Property Address: 1" 5_ Property Owner (;Tease print . e Phone: Property Owner Email: Mailing Address: (if different than propertyaddress) Address. City, Mate, i rchitect(Engirl r E-mail: Phone.- Contractor: h e:Contr or: Contractors City License Phone.. Contractor E-mailAddress: � Sub Contractors: le cal: Plumbing: Mechanical: WWII. City License # W,k City Ucense # W,R. City License # Other City Licensed Sub: Other City Licensed Serb: City license # City License # Complete let all information on BOTHsides of this form � • . w s � � SIR x . a.• a . •x . * . r x amount at materials to be used, d, etc. 4 7,2 Vf44 ILA Sg, FULF Stu's Galton Amps Squares Other INSPECTION RECORD o ccuDancv/Tvpe ®°INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. le IC/ U. IvU/JLD Electrical (Underground) 7s !1 INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS J OB FOUNDATION INSPE Plumbing (Underground) INSPECTOR INITIALS COMMENTS: Footings /Caissons Heating (Underground) Stemwall / (CEG) Co Encased Ground DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS Reinforcing or Monoli Building Final Weatherproof/ Frenc Fire Department Sewer Service Lines R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. Wat er Service Lines rUUR NO UUNGRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) 7s !1 1 y E 2 Plumbing (Underground) Heating (Underground) DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS Sheathing Building Final Lath /Wall tie Fire Department Mid -Roof R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. Electrical Service Rough Electric Rough Plumbing I� ; Gas Piping Rough Mechanical ABOVE INSPECTIONS TO BE Framing SIGNED PRIOR TO PROCEEDING Insulation Drywall Screw FINALS Electrical 7s !1 1 y E 2 Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. I OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER 4, Inspection Type R P Job Address t-&. !o I LLS 3'7 'Permit Number >ISS 1 i i Kr_ . Inspector: �r�aAMIPM City of Wheat Ridge �r Residential Solar PERMIT - 110655 PERMIT NO: 110655 ISSUED: 06/09/2011 JOB ADDRESS.: 4120 BALSAM ST EXPIRES: 06/08/2012 DESCRIPTION: Install 2.53 kw roof mounted solar system * ** CONTACTS * ** owner 303/725 -5812 Mariann Storck sub 888/765 -2489 Jared A Miller 11 -0035 SolarCity ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0325 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED. PROJECT VALUATION: 8,900.00 FEES Residential Solar 500.00 Total Valuation .00 ** TOTAL ** 500.00 Dam a. Conditions: MV: Approved per plans and red -line notes on plans. Must comply with 2006 IRC, 2005 NEC and all applicable City of Wheat Ridge Municipal Codes. Subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and /or its' accompanying approved plans and specifications. Signature of OWNER o+�CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of a applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field p ti Signature of ie uilding Offical Date INSPECTI N REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. <' City of R l heat ° �Ce COMMUNITY I�GV @LOPMGN "C Building & Inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 'Office: 303 -235 - 2855 " Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application `sa, PropertyAdd_ress 'S' /.Z. D l.�c.,lf«n:" f�,� G✓ ✓L.e.c� �iaO� Ct77 P Owner (please print): _ yrlQry'gwvt Phone1y_?- ?2 - S ' 6 /Z Mailing Address: (if different than property address) Address: fas' 2 City, State, Zip:, Cont'racto: Contractors City License #: Phone: SWbC6 #40-t- rs.' Electrical fn'./C, 1 (fv+"f Plumbing: Mechanical City License # City License # City License # bescribtlot%`fWUOr�`s' / ry+t r r °a�t(a�J fn �ua ontC� t ✓2C %r value: $ d o 1 816 Review Fee (due at time of submittal): 5bo . J� Squares BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and -. _. allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full - responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described :work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINTNAME: �trt.Qr. SIGNATURE: DATE: �ZON11jG COMMENTS -� r' ✓ ✓✓ ✓/ "' } J�i✓g '' a ..�'�' �S r �r �� ✓'`✓�' "' s `,,`^y ii ✓ ✓' vim. ✓ �✓� ✓ �� 70[ling ri ✓i sv"- ��; � j- �y ,,,� ✓�� "", l /r�� ✓,✓i �✓u' � �i1 r✓ ti� �c�l �5� �d���`� R0Y1eWer r l 't ✓ �✓ ✓ru �' � +S ,Si. Y ,� vprS rr �. ,✓ f 3"S ^' Z � w'6yf��, -.'a' /✓ ✓ jai �' 'ss. ? ✓' ;✓,�,. ✓. � /3�''^i�, ✓ v r � x �� ✓. �.✓`�,^,�t,r � �� /�ai� �! ,=' ✓ r � x �T �� � =' �'� �BUILOING'DEPARTMENT CAMtvtENTSs ., .:5. %✓" �: y � V .�✓� ✓!� '. c s�z��;,;'�?,+,ew"s� ✓ '��^�3! =s'�t ,,�� �; Y "� i ✓ ✓ z/✓ 5 ."< *' S u f Jk �,t ( v9 V J' O N✓P G ) N' to l r Z� *^'✓ r ✓r �✓ I �T'TU ? 5` � ✓2 ?'✓ � "� (�vf+`..°t � �,� ✓r ✓� Pr RCVJOWer f � �..� ✓P� �✓ ✓,..� t/� i� �:�' ✓✓. x7h- ✓y ^ �✓ s?` �IV� .✓py �' ✓��r raf i, �........................................�/. ✓'� t? ✓f . �.jdT z,y ✓ - ✓ K� ✓,f, �+v+�"� mil +s r f✓stiyan ✓ . , ;T�` ' s'�? , ,n✓^... ✓✓� r S ,. ✓ �. s.,, ,< .... � �^..tiY,� ✓ /z .::, .,�_. ✓, `i . _4' ri ,. �',, e . i.X',"' � w I ,.�. ..r.,. r:., ,,. l ' ✓, i✓ ✓ r� ✓ � r y/✓ Iy✓„ l. "�, � .� ✓ q f � � in^ � ✓ '� iT s � ✓ g FIREDEPARTryIENT�'papproved W� comments /O disapproved ✓ 37 go re�ey✓IegWred✓ Bldg Valuation$ 5/31/2011 800167 - Storck.xlsx ��C6RPw % 66 ' 0 Wheat Ridge Building Department aemn��' ' N — UILDING A rmved ASIRL OFF DATE 3055 Clearvi Way Valid ty of permit: a issuance of a permit or approval of plans, spedfications- San Mateo, CA. 99402 and computations shall not he a permit for, or an approval of, any violation to, any of the provisions of the building code or -of any City ordinances. (888)- SOL- CITY(765.2489) 1 www -solarMintitavresuming to. giveauthoritytoviolateorcanceltheprovisionsofthe, building codes or other ordinances of the City shall notpe valid. STRUCTURAL DESIGN CALCULATIONS by John A. Calvert P.E. REPORT PREPARED FOR: SolarCity, Inc. 3055 Clearview Way San Mateo, CA. 94402 888- 765 -2489 OWNER: Mariann Storck 4120 Balsam St. Wheat Ridge, CO. 80033 303 - 725 -5812 PROJECT DESIGNED BY: SolarCity, Inc. 3055 Clearview Way San Mateo, CA. 94402 888- 765 -2489 APPROVED Subject to Field Inspections Wheat Ridge Building D i Signed...... n CheKker `.Z. (k 5/31/2011 800167 - Storck.xlsx i Ut a. 3055 Clearview Way San Mateo, CA. 94402 1888)-SOL -CITY (765 -2489) I www.solarcity.com Calculations by: JAC Reviewed by: JAC Table of Contents 1 Wind load Calculations for Open Structure Component and Cladding 2 Solar P➢ System a Rack Dead Load Determination 3 Reef Dead load Determination 4 Rafter /Beam calculations 5 Appendix • image from Google Earth showing Wind Exposure a Lat/Lon • Seismic Spectral Response data from USGS web site Note: Seismic Check is not required because Ss = 0.226 < OAD per 1613.1.1 in 2006 IBC Design Criteria Snow load = 30 psi Live load = 20 psi Dead Load =11.2 psi Basic Wind Speed =100 mph Exposure'B' 5/31/2011 800167 - Storck.xlsx AF Wind 3 Input Variables Calculations and Values Required Variables Design Wind Pressures based upon: mean roof height, ft ' '13 ASCE 7 -05 Chapter 6 Wind Loading Exposure Category (6.5.6.3) > B Basic Wind Speed (Figure 6 -1 or local data) 100 Equation 6.5.13.3: Component and Cladding Elements Importance Factor (1 for residential) 1 Wind Pressure P = qh *Cn *G roof shape pitched 6.5.10: Velocity Pressure Roof Slope (degrees); 22.0 " qh = 0.00256 *Kz *Kzt *Kd *VA2 *1 Roof Zone 3 contiguous sq. feet of array 35 From Table 6 -3: least width of the building 45 Kz =0.70 obstructed wind flow? : TRUE From Figure 6 -4: Kzt= 1.00 Local Topographical Features From Table 6 -4: (choose "standard "or refer to pictures right, and below) Kd = 0.85 type of hill none From figure 6 -1: Hill Height (h) (ft) V = 100 slope of hill (degrees) From table 6 -1: horizontal distance from hilltop to house(x) I = 1 height from bottom of hill to mean roof height(z) From Velocity Pressure Eguation: qh = 15.23 Design Wind Pressures From Figure 6 -19B P (Ibs. per sq. ft.) = qh *Cn *G Cn (uplift) = -2.12 Pd (downforce pressure) = 10.36 Cn (down) = 0.80 Pu (uplift pressure) = -27.45 From 6.5.8.1 G = 0.85 Max Tributary Area Max Uplift Force on a Single Standoff Individual Rows in Portrait Pmax Ibs. = Amax *Pu Yingli YL230P -29b Pmax = -298 Amax (sq. ft.) = 0.5 *L *X Factor of Safety = FI *D *NI /Pmax L (length of panel in ft. perpendicular to rail) X (distance between standoffs in ft.) 5.42 4 250 = FI (pullout capacity of lag (Ibs /inch)) 2.50 = D (minimum lag thread depth) Y (distance between standoffs in ft.) 2.67 2 = NI (number of lags per standoff) Amax = 10.84 4.19 =Factor of Safety Point Load Calculations Dead Load Calculations PL Ibs = Amax *DL DL (Ibs /sq. ft.) = (Mm +Mh) /(L *W) PL— 32 L (length of Yingli YL230P -29b modules) 5.42 W (width of Yingli YL230P -29b modules) 3.25 Mm (weight of Yingli YL230P -29b modules) 43.70 Mh (weight of hardware per module) _ ` 8.00 Version 1 8 DL= 2.94 5/31/2011 800167 - Storck.xlsx Flush DL 4 CALCULATION OF SOLAR PHOTOVOLTAIC ROOFTOP SYSTEM DEAD LOAD MODULE AND STAND -OFF CHARACTERISTICS Module Make & Model: Panel Configuration: Nmod = 11 Lmod = 5.42 ft W mod = 3.25 ft Amad = 17.62 sf Wt = 43.70 lb DLmod = 2.48 psf Yingli YL230P -29b Rows in Portrait Quantity of Yingli YL230P -29b modules Length of one Yingli YL230P -29b module Width of one Yingli YL230P -29b module Area of one Yingli YL230P -29b module Weight of one Yingli YL230P -29b module Unit dead load of Yingli YL230P -29b modules Solar Rail Make & Model: SolarCity Rail Solar Rail Configuration: X -X Solar rails running in X -X direction Wt raii = 0.68 plf Unit weight of aluminum solar rail, plf Stand -off Make & Model: SolarCity Canopy Wtstandoff = 1.75 lb Unit weight per stand -off assembly PANEL AND RACK SYSTEM GEOMETRY O = 22.0 deg Tilt of panel system from horizontal Oroof = 22.0 deg Slope of roof mounting surface hmin = 0.33 ft Least panel height above roof surface (vertical . dimension) hmax = 0.33 ft Greatest panel height above roof surface (vertical dimension) h = 0.33 ft Mean panel system height above roof surface (vertical dimension) Lx -x = 19.50 ft Array length in X -X Direction S. = 4.00 ft Standoff spacing in X -X Direction N s , x - = 5 Number of standoffs in X -X Direction L - 10.84 ft Array length in Y -Y Direction (actual dimension at panel tilt O) Lh, - = 10.05 ft Horizontal projection of array length in Y -Y Direction S = 2.67 ft Standoff spacing in Y -Y Direction N s , y _ y = 4 Number of standoffs in Y -Y Direction 5/31/2011 800167 - Storck.xlsx Flush DL 5 DETERMINATION OF SYSTEM DEAD LOAD FOR SEISMIC ANALYSIS COMPONENT AREAS, LENGTHS, AND QUANTITIES Asystem = 211 sf Gross area of solar PV system Amodules = 194 sf Net area of solar modules only Nrall = 4 Number of solar mounting rails Lrall = 78 ft Approximate total length of solar mounting rail Nstandoff = 20 Number of stand -off assemblies DEAD LOAD CALCULATION Length or Unit Component Component Quantity Weight Weight, lb Solar Modules 11 x 43.70 lb = 481 Solar Rails 78 ft x 0.68 plf = 53 Stand -off Assemblies 20 x 1.75 lb = 35 Subtotal for Hardware = 88 lb Total System Seismic OIL = 569 lb Weight of Hardware per Solar Module = 8.00 lb Weight of Modules per square foot of PV System = 2.27 psf Weight of Hardware per square foot of PV System = 0.42 psf Total Seismic System Weight per square foot = 2.94 psf 5/31/2011 800167 - Storck.xlsx Roof DL 6 APPLICABLE CODE: 2009 International Building Code Determination of Dead and Live Loads: Roof Pitch 5:12 Dead Load @ Roof Pitch = Ceiling: Insulation (Bottom Chord) 2 x 4 @ 24 in. o.c. (Web) 2 x 4 @ 24 in. o.c. 518 in. Gypsum Board Miscellaneous Walls, Ext.: Wood Siding Building Paper 1/2 in. Plywood or OSB 2 x 4 @ 16 in. o.c. 1/2 in. Gypsum Board Insulation & Misc. Walls, Interior 1/2 in. Gypsum Board 2 x 4 @ 16 in. o.c. 1/2 in. Gypsum Board I I.zu 1.083 12.13 1.42 1.15 0.73 2.80 1.50 7.60 5.00 0.50 1.50 2.00 2.20 1.00 12.20 2.20 2.00 2.20 6.40 Calculations by: JAC Checked by: JAC LIVE LOAD IBC 1607.11.2 L = 20 psf Arab = <= 200 sf R, = 1 22.6 deg R = 0.95 L L *R, *R 19 psf 10 psf DEAD LOAD Element Materials Wt. (psf) Roof: Comp. Shingles (2 layers) 6.00 Roofing Paper 0.50 3/4 in. Plywood or OSB 2.30 (Top Chord) 2 x 6 @ 24 in. o.c. 1.15 Miscellaneous 1.25 Roof Pitch 5:12 Dead Load @ Roof Pitch = Ceiling: Insulation (Bottom Chord) 2 x 4 @ 24 in. o.c. (Web) 2 x 4 @ 24 in. o.c. 518 in. Gypsum Board Miscellaneous Walls, Ext.: Wood Siding Building Paper 1/2 in. Plywood or OSB 2 x 4 @ 16 in. o.c. 1/2 in. Gypsum Board Insulation & Misc. Walls, Interior 1/2 in. Gypsum Board 2 x 4 @ 16 in. o.c. 1/2 in. Gypsum Board I I.zu 1.083 12.13 1.42 1.15 0.73 2.80 1.50 7.60 5.00 0.50 1.50 2.00 2.20 1.00 12.20 2.20 2.00 2.20 6.40 Calculations by: JAC Checked by: JAC LIVE LOAD IBC 1607.11.2 L = 20 psf Arab = <= 200 sf R, = 1 22.6 deg R = 0.95 L L *R, *R 19 psf 10 psf - - — 800167- Storck— 5=27=1-1 - '� KC�70 = 4120 Balsam St 2:49pm Wheat Ridge, CO 80033 1 of 1 xeyBeam® 4.5Wa IanBeamFngve4.M1 Materials Database 1282 Member Data Description: Rafter Member Type: Joist Application: Roof MP1 Rafter Top Lateral Bracing: Continuous Slope: 5.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC / IRC Dead Load: 11 PSF Deflection Criteria: L/180 live, L/120 total Snow Load: 30 PSF Deck Connection: Nailed Filename: RaftecKY6 Other Loads Type Dead Other (Description) Begin End Start End Start End Category Point (PLF) 2' 9.00" 16 0 Snow Point (PLF) 5' 3.00" 16 0 Snow Point (PLF) 7"10.00" 16 0 Snow Point (PLF) 10' 5.00" 16 0 Snow Point (PLF) 12'11.00" 16 0 Snow Point PLF 15' 5.00" 16 0 Snow 1 5 0 8 6 0 (D Q 7 8 0 1 Bearings and Reactions Location Type Input Length Min Required Gravity Reaction Gravity Uplift 1 1' 5.000" Wall 3.500" 1.500" 454# -- 2 9' 11.000" Wall 3.500" 1.500" 960# -- 3 17' 4.375" Wall 3.500" 1.500" 252# Maximum Load Case Reactions usetl fio- Mlyi,g palm loads is, line Imod.) W .aryl, members Dead Snow 1 162 #(81 pill 292 #(146p1f) 2 371 #(186plf) 589 #(295plQ 3 92# 46 I 161# 80 If Design spans 1' 6.438" (left cant) 9' 2.500" 8' 0.812" Actual Length 19'2.875" Product:DFL #2 2x 6 24.0 "O.C. Component Member Design has Passed Design ChecksP Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 492.# 975.# 50% 4.82' Total load D +S Negative Moment 763.# 975.# 78% 9.92' Total load D +S Shear 411.# 1138.# 36% 9.49' Total load D +S Max. Reaction 960.# 3633.# 26% 9.92' Total load D +S LL Deflection 0.1056" 0.6139" L/999+ 5.24' Total load S TL Deflection 0.1748" 0.9208" L/632 5.24' Total load D +S LL Dell., Lt. - 0.0589" 2L/625 0' Total load S TL Defl., Lt. - 0.0993" - 2L/370 0' Total load D +S Control: Negative Moment DOLS: Live =100% Snow =115% Roof =125% Wind =160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 All pmdumnamesmetmdemadaofMarmsp bveomem JAC E, r a. Sala rCi ty "' Eti; ngmgC)1989-2005 by e,P,ises LL Ne"unk EntC ALLRIGIRS RESERVED. `j .� ,.,t,, ( 3055 Clearview Way ^P95sing is earned aswhen(be mambo,floorpist, heam orgnistshown on this dmMN memos applicable design cross for Loads, Loading Conditions, and Spans listed on able sM1eet San Mateo CAA 94402 The design must be,nviee ol bye qualified deslgnmordesign pmlessimmi as ,equLetl forapproval. This design assumes product installation according to the m mulactureis specifications. (888) 765 -2489 _a%\ � .� .. � £? .: M-Dz�« 800167- storck untitled Conterminous 48 States 2005 ASCE 7 Standard Latitude = 39.77 Longitude = - 105.09 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 0.226 (Ss, site Class B) 1.0 0.058 (S1, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 39.77 Longitude = - 105.09 Spectral Response Accelerations SMs and SM1 SMS = Fa x Ss and SM1 = FV X S1 Site Class D - Fa = 1.6 ,FV = 2.4 Period Sa (sec) (g) 0.2 0.362 (SMs, Site Class D) 1.0 0.138 (SM1, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 39.77 Longitude = - 105.09 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D - Fa = 1.6 ,FV = 2.4 Period Sa (sec) (g) 0.2 0.241 (SDs, Site Class D) 1.0 0.092 (SD1, Site Class D) Page 1 30' TO R FRONT OF HOUSE J Q m GATE u (TYP.) 0 /1 0— 0 -E]-- APPROVED Subject to Field lnspecticns Wheat Ridge Building Dept. Date 0 �tl. AC Signed ::......... . ............Plan Checker M F 0' 1 LEGEND AC TOR O (E) UTILITY METER (6) © INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS. (3),(4),(5),(6) Inv � DC DISCONNECT (4),(5) © AC DISCONNECT (3),(4),(5),(6) MP1 ROOF MOUNT O JUNCTION BOX PITCH: 22 ARRAY PITCH: 22 AZIMUTH: 90 1 ARRAY AZIMUTH: 90 Oc DC COMBINER BOX (7),(9) MATERIAL: Comp Shingle Roof STORY: 1 M DISTRIBUTION PANEL (1),(2) RAFTERS A SIZE: 2x6 Ec SPACING: 24" O.C. LOAD CENTER (3),(4),(5),(6) PV3 SUPPORT: 2x4 PURLIN MAX. SPAN: 8' -5" O DEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR NOTES - -- CONDUIT RUN ON INTERIOR 0.75" DECKING GATE - -- INTERIOR EQUIPMENT 0 AMPED & SIGNED S TRUCTURAL ONLY e2 ® N oa SITE PLAN o® 43019 �o w e Scale: 1/8" = V t' MIN. "" OW SETBACK Al- / Al GATE 0 1' 8' 16' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE OF ANYONE EXCEPT WROTE INC.. NOR SHALL IN NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARG1TY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B -8001 67 00 PREMISE OWNER AHd Wheat Ridge DESCRIPTIOR: STORCK MARIANN STORCK RESIDENCE ' 4120 BALSAM ST. 2.53 KW ROOF MOUNT PV SYSTEM WHEAT RIDGE, CO 80033 * PAGE NAME 3037255812 SITE PLAN DESIGN: SEAN THIEL �- � M w_ ��'�` \/ J a olarCito MARKET REST 17 YINGLI YL23oP -2sb ADesignerSi nature. pg 9 1 PROJECT MANAGER: * MOUIRING SYSTEM: SOLARCITY CANOPY —C 3055 CleaMew Way San Mateo, ca 99902 T:(65O) 638 -1028 ( F:(65O) 638 -1029 (gg8) - SOL - Q Y(]65 -2969) 1 wWW.mlarcity.com SHEET: REV. DATE PV 2 5/6/2011 PAYMENT TYPE: LEASE IN TER: 1 SMA #SUNNY BOY 3000US 4' BETWEEN APPROVED Subject to Field Inspections Wheat RidgeBuildi n pt Date.\! Sighed......... ............Plan Checker SOLAR PANEL ATTACHED WITH mnnl CLAMPS, J" BOLT WITI- SOLARCITY SOLAR RAIL & BOLT CANOPY BOLT ASSEMBLY CANOPY FLASHING & BRACKET (E) COMP. SHINGLE (E) ROOF DECKING " CIA LAG BOLT (2 —j" EMBED, MIN) (E) RAFTER STANDOFF Scale: 1 1/2" = 1' (1; ( (3; (4,' INSTALLATION ORDER LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. CUT SHINGLE AROUND FLASHING. SEAL PILOT HOLE AND BOTTOM OF CANOPY BASE WITH POLYURETHANE SEALANT. LAG CANOPY BRACKET INTO RAFTER WITH (2) A" DIA. LAG BOLTS. NSTALL CANOPY FLASHING ONT BRACKET. ATTACH RAIL WITH CANOPY BOLT. Scale: 1/2 " =1' -0" °® 43019 Z R ops (E) 20 PURLIN (E) 2x4 PURLIN A I (E) LBW _[k (E) LBW RAFTERS: 2x6 @ 24" O.C. SUPPORT: 24 PURLIN MAX SPAN: 8' -5" SIDE VIEW OF MOUNTING PLANE 1 (E) 2x6 RAFTERS (E) 1x8 RIDGE BEAM (E) 1x8 COLLAR TIES (E) 2x6 CEILING JOIST Scale: 1/4 " =1' -0" CONFIDENTIAL —THE INFORMATION HEREIN C D FOR CONTAINED SHALL NET BE USED THE N OF ANYONE T B E U E FOR T INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANLZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISS OF SOLARCITY INC. JOB NUMBER - JB800167 00 PREMISE OWNER AW Wheat Ridge DESCRIPTION: STORCK, MARIANN STORCK RESIDENCE 4120 BALSAM ST. 2.53 KW ROOF MOUNT PV SYSTEM WHEAT RIDGE, CO 80033 * PAGE NAME 3037255812 STRUCTURAL VIEWS VESGN: SEAN THIEL �►�� j ►, �7�fGI V' o NARKET: REST MODULES: MODULES: 11 YINGLI YL23OP -29b ADesignerSlgnature.JPg 1 PRUCT MANAGER: * MOUNTING SYSTEM: SOLARCITY CANOPY —C 3055 Cleamim Wa San Mate, CA 94402 (888)SO650638-1 65- 2489) F: ( 6 50 ) 1 www.mlarrcty.= SHEET REV. DATE PV 3 5/6/2011 LEASE 1 SMA SUNNY BOY 3000US # ® 24" SPACING n FRONT VIEW OF MOUNTING PLANE (N) DF #2 2x6 PURLIN SUPP ATTACH TO (E) PURLIN WITF ROW OF 10d NAILS AT 6" STAGGI (N) DF #2 2x4 FLAT TO SUPPORT (N) PURLIN AND EXTEND TO WITHIN 4" OF BOTTOM OF (E) PURLIN. ATTACH TO (E) SUPPORT WITH 10d NAILS AT 6" O.0 NOTE: SPLICES SHALL OCCUR DIF OVER STRUTS AND SHALL HAVt A . MIN 2' -0" OVERLAP. SIDE VIEW OF PI (N) 2x6 DF #2 PURLIN (N) (4)— 10d COMMON (N) SIMPSON LS30 CLIP. FILL ALL HOLES. 2x4 STRUT AT END OF NEW STRUT AT NORTH END OF PURLIN APPROVED Subject to Field inspections 43019 Wheat, Ridge Building Dent. Date. A. (p•2, 1\ Signed....... T .............Plan Checker Scale: 1/2 " =1' -0" � r t? R. CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE OF ANYONE EXCEPT O INC., NOR SHALL IN WHOLE NOR SHALL IT BE DISCLOSED IN WHOIE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION DE SOLARCITY INC. JOB NUMBER J B -8 0 016 7 00 PREMISE OWNER NQ Wheat Ridge DESCRIPTION: STORCK MARIANN STORCK RESIDENCE 4120 BALSAM ST. 2.53 KW ROOF MOUNT PV SYSTEM WHEAT RIDGE, CO 80033 * PAGE NAME 3037255812 STRUCTURAL VIEWS DESIGN: SEAN THIEL A ' olarc'},/ Q `yo NARNEE REST M (11) 11 YINGLI YL230P -29b .�nesl nerSl nctture.,JPg 9 9 PRUEECT MANAGER: * MGUNTIRG ss,EM: SOLARCITY CANOPY —C 3055 Clearview Way T San Mateo, CA 94402 (650) 638 -1028 1 F:(650) 638 -1029 (888 )-5019 (765 -2489) 1 www.solarcity.com SHEET: REV: DATE 5 6 2011 PV 4 / / PAYMENT TYPE: LEASE IN iQE 1 SMA SUNNY BOY 3000US # RT OIST UPGRADE Scale: 1/2 " =1' -0" UPLIFT CALCULATIONS Input Variables JOB NUMBER J13-800167 Calculations and Values Required Variables DESIGN: SEAN THIEL Design wind pressures based upon: Mean roof height: NODULLS: 17 YNGL YL230P -29b ASCE 7 -05 Chapter 6 Wind Loading Exposure category: ff MOUNTING SYSTEM: SOLARCITY CANOPY -C Basic Wind speed (or city in the future): SHEET; REV.: DATE: PV 5 5/6/2011 Equation 6.5.13.3: Component and Cladding Elements Importance factor (1 for residential): Wind pressure P = qh *Cn *G Roof shape: pitched 6.5.10: Velocity pressure Roof angle (degrees): 22 qh = 0.00256 *Kz *Kzt *Kd *VA2 *1 Roof zone: 3 Contiguous sq. feet of array: 35 From Table 6-3: Least Width of the building: ' 45 Kz = 0.70 Obstructed wind flow? TRUE ' From Figure 6 -4: Kzt= 1.00 Local Topograhphical Features From Table 6-4: Kd = 0.85 (choose " standard "ormter to pictures right, and below) '' none ' Type of hill From figure 6-1: Hill height (h) (ft): V= 100 4 Slope of hill (degrees): From table 6 -1: Horizontal distance from hilltop to house (x): I = 1 eight from bottom of hill to mean roof height (z): From Velocity Pressure Eguation: qh = 15.23 Design Wind Pressures From Figure 6 -19B P (Ibs. per sq. ft.) = qh *Cn *G Cn (uplift) = -2.12 Pd (downforce pressure) = 110.36 Cn (down) = 0.80 Pu (uplift pressure) = -27.45 From 6.5.8.1 G = 0.85 Max Tributary Area Feet Inches Individual Rows in Portrait X (E -W distance between standoffs) - 4 0 Yingli YL230 P -29b Y (N-S distance between standoffs) = 2 9 Amax (sq. ft.) = 0.5 *L *X L (length of panel in ft. perpendicular to rail) ? 5.42 X = 4.00 ' Module Rail Max Span / Cantilever (in) _ . 751/2 ':351/2 , Y = ' 2.75 Max Uplift Force on a Single Standoff L = r =' WA'_ - Pmax Ibs. = Amak*PU Amax= 710.83 Pmax? -297" Factor of safety = FI *D *NI/Pmax 250 = FI (pullout capacity of lag (lbs/inch)) Dead Load Calculations 2.50 = D (minimum lag thread depth) DL (Ibs /sq. ft.) = (Mm+Mh) /(L *W) 2 = NI (number of lags per standoff) L (length of Yingli YL230 P -29b modules) 5.42 4 21 = Factor of safety W (width of Yingli YL230 P -29b modules) 3.25 Mm (weight of Yingli YL230 P -29b modules) 43.70 Point Load Calculations Mh (weight of hardware per module) = 8.43 PL Ibs = Amax *DL PL = 32' DIL = ! 2.96, `i Version 6 8 APPROVED Subject to Field Inspections Wheat Ridge Building D P t. Date.lEv }1 !:) I Signed ......... ............Plan Checker CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE NOR SHALL OF ANYONE EXCEPT IN VIHO INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANVATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIWE SOLARCITY EQUIPMENT, NITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER J13-800167 0 0 PREMISE OWNER AHJ Wheat Ridge DESCMP➢gV: STORM MARIANN STORCK RESIDENCE 4120 BALSAM ST. 2.53 KW ROOF MOUNT PV SYSTEM WHEAT RIDGE, CO 80033 * PAGE NAME 3037255812 UPLIFT CALCULATIONS DESIGN: SEAN THIEL � �ji Of ar _ity _V A' ■ V - `�o MARKET, REST NODULLS: 17 YNGL YL230P -29b . \DeslgnerSlgnature.Jpg 1 PRO.ECT MANAGER' * MOUNTING SYSTEM: SOLARCITY CANOPY -C 30550earview Way San Mateo, CA 94402 (ggg)30L0CrY(765- 2489) 1 s ...Sdarcry.can SHEET; REV.: DATE: PV 5 5/6/2011 LEASE 1 SMA SUNNY BOY 3000US # MODULE VOLTAGE RATINGS Voc: 37 VDC Vpmax: 29.5 VDC *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. G1130478 (E) 125A MAIN ELECTRIC SERVICE PANEL (E) 100A/2P MAIN CIRCUIT BREAKER ZINSCO PANEL ML12(6 -12) (E) WIRES AND CONDUIT - (E) LOADS (2)BURNDY# BIPC1 /0 -2 Insulation Piercing Connector r ------ ---------- ------------ - -- - -1 ARRAY GROUND ELECTRODE: LOCATE (N) GROUND ROD PER NEC 690.47(D) TO GROUND THE ARRAY. CONNECT ' A SEPARATE (N) #6 GEC FROM THE ELECTRICALLY BONDED ARRAY FRAME TO THE (N) GROUND ELECTRODE. THE (N) GEC SHALL BE KEPT SEPARATE FROM ALL OTHER NON- CURRENT CARRYING METAL PARTS. i AWG #8, Solid Bare Copper (1) Conduit Kit; 1/2" EMT (1) GEC OR // AWG #6, Solid Bare Copper (1 ) L - Ground Rod; 5/8" x 8', Copper (1) SUPPLY SIDE CONNECTION PER ART 690.64(A). DISCONNECTING MEANS SHALL BE SUITABLE AS SERVICE EQUIPMENT AND SHALL BE RATED IN ACCORDANCE WITH ART 230.79(D). (1) AWG #6, THWN -2, Black (1) AWG #6, THWN -2, Red (1) AWG #6, THWN -2, White N (1 ) Conduit Kit; 3/4" EMT • Vmp = 240 VAC • Imp = 12.5 AAC (1) AWG #10, THWN -2, Black (1) AWG #10, THWN -2; Red (1) AWG #10, THWN -2, White NEUTRAL (1 )AWG #10, THWN -2, Green EGC (1 )Conduit Kit; 1/2" EMT • Vmp = 240 VAC 1 STRING OF 11 MODULES (11)YINGLI # YL230P -29b PV Module; 230W, 206.6W PTC, MC4, Silver Frame, (2)AWG #10, USE- 2 /RHW -2, Black (1 ) AWG #10, Solid Bare Copper (1)Conduit Kit; 1/2" EMT Dc. Dg • Voc = 407 VDC ------------ - - - - -IX IGND' . Vmp = 324.5 VDC • Isc = 8.4 ADC l . Imp = 7.8 ADC SMA I SUNNY BOY 3000US (1) Inverter; 30u0W, 240V, 95.5% EFF. 1 I MOUNTED OUTSIDE INVERTER I N ND I� I 1 I z61 0I0 Ironn I I I I I I I • Imp = 12.5 AAC MOUNTED OUTSIDE I I L_ t BOTTOMTOP L1 Li GC LINE L7 LOAD L2 1 I N _ ________ ___ _ GND EGC______ ____ E99c I I APPROVED Subject to Field Inspections Wheat Ridge Building egt Date.... V! Signed........... ..........Plan Checker MOUNTED OUTSIDE TO 120/240V - i SINGLE PHASE ` -- -- UTILITY SERVICE I I I AWG #6, Solid Bare Copper ( 1 ) BOND (N) #6 GEC TO BOTH (N) GROUND ROD AND (E) GEC WITH IRREVERSIBLE CRIMPS PER ART 250.64(C) AND ART 250.66(A) Ground Rod; 5/8" x 8', Copper( 1 ) CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARaTY INC. NOR SHALL IT BE DISCLOSED IN NNOIE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATON, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC- #6 JUMP UNBROKEN THROUGH i INTEGRATED DC DISCO ' _____ ____ __________________ ________ - -_ . __ ______ ________GEC__- _________GECJ (1)CUTLER- HAMMER # DG222NRB (1)CUTLER- HAMMER # DG221URB Disconnect; BOA, 240Voc, Fusible, NEMA 3R - (2)FERRAZ SHAWMUTT # TR20R MILBANK # U4801- XL -5T9( 1 ) Fuse; 20A, 250V, Class RK5 Meter Socket; 200A, #6 -350, Ringless (2) FERRAZ SHAMUT # R632 METER SUPPLIED BY UTILITY - Fuse Reducer; 3 A Fuse for 60A Clip, 250V MOUNTED OUTSIDE - (1)CUTLER- HAMMER # DS16FK Class R Fuse Kit - (1 ) AWG #6, Solid Bare Copper GEC JOB NUMBER JB- 800167 00 STORCK, MARIANN 4120 BALSAM ST. WHEAT RIDGE, CO 80033 3037255812 Disconnect; 30A, 240Vac, Non - Fusible, NEMA 3R STORCK RESIDENCE 2.53 KW ROOF MOUNT PV SYSTEM PAGE NAME SEAN THIEL \DeslgnerSlgnature.,Jpg REV: DATE PV 6 5/6/2011 3055 Cleo" Way San Mateo, CA 99902 T:(650)63 &1028 I F:(650)638 -1029 - SOL {ITY(] G SYSTEM: ARCITY CANOPY SMA # SUNNY I 1. Conductor sizin per Art de.8raxn ELECTRICAL CALCULATIONS a. Conductor must have 30 d e g . C ampacity >= 1259 of continuous current per Art 215.2(A)(1). Module 11 ' O6z6 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 5_7.5 Inverter 1' 1 Vdrop = Im * 2 * Length ResistanceZ / (Vmp) b. Conductor must have (after corrections for conditions of use >= Module's Imp (A) Max Length (ft) Wire continuous current per Table 310.16. Inverter 2- ,r, , (;.: vi , . .� ;y- := '? String: 1 7.8 1 30 IC AWG 1 01 at Max Ave Hi: 93 deg F Module. - �`�� Vdrop = 7.80 A 60 ft * 0.00124 Ohms / 283 V = 0.20% c. Evaluate conductor temperature of terminations per 110.14(C). Inverter 3' € Branch: 7.8 50 AWG 1 at Max Ave Hi: 93 deg F Ampacity of wire derated for conditions of termination must be Module' Vdrop = (7.80A * 100 0.00124 ohms) / 283V= 0.34% >= continuous current *1.25. All string terminations are rated at Inverters Totalvolta edro in DC conductors= o.5s ^i 90• C Inverter: 12.50 10 AWG1 at 240V Total: modules Total Inv Pwr PTC Vdrop = 12.50 A * 20 ft * 0.00120 Ohms / 240 V 0.13% 2. OCP Sizing Aft 690.8(B)(1) Photovoltaic Module Electrical Specifications: Total STC ,BEN -Wik3 Combined: 12.50 0 AWG 1 at 240V 9 P er Voc= V deg F de C Vdrop = (12.50A * Oft * 0.00120 Ohms) / 240 V 0.00 a. Round up to next size per Art 240.4(8) Vmp= V Record Low Temp. ;: 13 Total voltage drop in AC conductors= 0.13% ------------------------------------------- Ise= A Max Average Hi Temp _. 932 Total voltage drop in AC and DC conductors = 3. Conductor Sizing per Art 690.8(B)(1) Imp= A a. Conductor must have 30 deg. C ampacity >= 1259 of continuous Tvoc= V /deg C current per Art 215.2(A)(1). Tisc= mAJdeg C Stnn e A and 2 Combined Stnn s Type A Voc Correction Method mull � a5a Branch Circuit Type A 171 modules per series string Sic"+IXAeSB �.'�„`,'" 1 �stnngs per branch 1- way wire length 50ft b. Conductor must have ti ft aer corrections for conditions of use >_ 71 1P Ylstl 'I Inverter Min vdc ln I n p ut: vdc ( ) _, . p . F.r continuous current per Table 310.16. Voc= V Min Vmp at Max Temp: Vdc voc= V Vmp= V Max Voc at Min Temp: _ - ;Vdc Vmp= V c. Evaluate conductor temperature of terminations per Art 110.14(C). Ise= A Inverter Max vdc Input: Vdc Ilsc= A Ampacity of wire derated for conditions of termination must be Imp= A Max String Size Imp= A >= continuous current *1.25. All branch terminations are rated at Icont- A Art690.8A 1 1 -way wire length It l ic on(= A Art690.8A 1 75• C min. 1.a Try USE- 2/RHW -2 at 90 deg C: Table 310.16 3.a Try Icont 1.25 = ( THWN-2/USE -2 at 90 deg C: Table 310.16 ___________ _______________________________ * (Amps) Icont * 1.25 = (Amps) 30 de Cam ampacity = 4. RCP Sizing 30 de C am aci = 3.b Icont (Amps) o. Round up to next size per Art 240.4(B) 1.b Icont= (Amps) Start ampacity ------------------------------------------ Start ampacity - Temp. derate ( % =F) 5. Conductor Sizing per Art 690.8(B)(1) Temperature derate ( % =F) Cndt. fill derate ( %_ #) a. Conductor must have 30 deg. C ampacity >= 1259 of continuous Conduit fill derate (% = #) Derated am aci current per Art 215.2(A)(1). Derated arrkpacity Temp table Term 1 Term 2 1.c Icont *1.25= (Amps) - 3.c Iconrl.25= (Amps) b. Conductor must have (after corrections for conditions of use) >= Ampacity Ampacity continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). 2 tcont *1.25 = (Amps) 3.d OCP size Ampacity of wire derated for conditions of termination must be OCP size = Combined Inverter Output >= continuous current *1.25. All inverter o t termina+inp - Service Voltage= 240 Volts - - ------ ->°rP� R 0 V E D rated at 75• C. Inverter T e A Out ut Total Inverter Power= Watts 1 -way wire length Oft , -r�a ;. ':" 1 -way wire 9Q`s_ft Icon( = # of inverters *max inverter current Art 690.8(A)(1) 6. OCP Sizing Icont= 5 A Art 690.8 A) 1 Icon(= (Amos Subject to Fieldl Inspections 4 Icont *1.25 = (Amps) A Art 690.8(B)(1) 6 Icon( *1.25= (Amps) °A Art 690.8(B)(1) a. Round up to next size per Art 240.4'(8) OCP size = A Art. 240.6(A) OCP size = A Art. 240.6(A Wheat Rid a Buildin Pt 5.a Try TFNVN 2 at 90 deg C: Table 310.16 7.a Try THWN -2 at 90 deg C: Table 310.16 7. Conductor Sizing per Art 690.8(B)(1) icont * 1.25 = (Amps) Icont * 1.25 = (Amps) a. Conductor must have 30 deg. C ampacit >= 1259 of contin 11 30 de Cam aci = 3o d Cam aci = current per Art 215.2(A)(1). bate A#�• 5.b Icont= (Amps) 7.b Icont - - (Amps) Start ampacity Start ampacity Plafl CI78CIC @f Temperature derate ( % =F) Temp. derate ( % =F) b. Conductor must have (after corrections orSWI11110ions•of s > ="""' Conduit fill derate ( % = #) Cndt. fill derate ( ^i = #) continuous current per Table 310.16. Derated ampacity Derated am aci 5.c Icon( *1.25= (Amps) 7.c Iconrl.25= (Amps) c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity Ampacity Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER J B -8 0016 7 O O PREMISE OWNER MU Wheat Ridge DESCRIPTION: DESIGN: STORM MARIANN STORCK RESIDENCE SEAN THIEL CONTAINED SHALL NOT BE USED FOR THE //r��� BENEFIT OF ANYONE EXCEPT M O INC., MARKET. MODULES So � l1M _'� \j NOR SHALL IT BE OUTSI T IN DISCL IN WHOLE E OR IN 4120 BALSAM ST. 2.53 KW ROOF MOUNT PV SYSTEM A ' ■ V - J yo PART TO OTHERS 0E THE RECIPIENT'S RESI 11 YINGLI YL230P -29b ORGANIZATION, EXCEPT IN CONNECTION PATH PROJECT MANAGER: MOUNTING SYSTEM: WHEAT RIDGE CO 80033 * . \DeslgnerSignature,,Jpg THE SALE AND USE OF THE RESPECTIVE * SOLARCITY CANOPY -C 3055 Ciea.!e Wa SOLARCITY EQUIPMENT, WTHOUT THE WRITTEN PAGE NAME SHEET: REV. DATE San Mateo, CA 94402 # ELECTRICAL CALCULATIONS PV 7 s /s/2o11 (gg8)SO ty.can PERMISSION of SOLARCITY INC. LEASE 1 SMA SUNNY BOY 3000US 3037255812 WARNING! ELECTRIC SHOCK HAZARDI EARNING! ELECTRIC SHOCK HAZARD! OPERATING VOLTAGE V MAXIMUM OPERATING A CURRENT PV MODULE A YIN SOLAR Power Your Life 4 1.1 2111 a Yingli Solar is a vertically integrated manufacturer of solar photovoltaic modules. Under one roof we manufacture our ingots, wafers, cells and modules. This ensures that we can tightly control our material and production quality, offering our customers leading product durability and sustainable performance backed by our 25 year limited power warranty *. PHOTOVOLTAIC DC DISCONNECT WARNING! ELECTRIC SHOCK HAZARD! V. V Vmp V Ise A Imp A fI iLv r_.. _... PERFORMANCE » High efficiency, multicrystalline solar cells with high transmission and textured glass deliver a module series efficiency of up to 14.1%, minimizing installa- tion costs and maximizing the kWh output of your system per unit area. » Power tolerance of +/-3%, minimizing PV system mismatch losses. QUALITY & RELIABILITY » Robust, corrosion resistant aluminium frame inde- pendently tested to withstand wind loads of 50 psf ensuring a stable mechanical life for your modules. » Take confidence In our modules with a 5 year limi- ted product warranty and a 25 year limited power warranty`. » Modules protected by box during transportation and with 20 modules in a box on-site waste is minimized. » Modules independently tested to ensure compliance with certification and regulatory standards. » Manufacturing facility certified to IS09001 Quality Management System standards. WARRANTIES S year limited product wanaoty Limited power warranty. 10 years at 90% of the minimum rated power output, 25 years at 80% of the minimum rated power output YINGLI 230W MODULE (YL230P -29b) ELECTRICAL PARAMETERS Elactncalparameters at 5TC0000 Mm 1 C AM 1 L5Gaccor n9ta EN 60904 3) Prwer cdrl. P_ 1!g 230.0 Paerreipdmlene¢s 1%3 }� 3 Vale. aBdnn 1 %1 Nl 0Ma9e e[Pne, Y, _. to] 245 Cartel d ft. I_ [A] L €0 Opeealr[Yn ealpge ll� IV] 310 5kht,i een smell Wt e.4o Man.'.. He NI �iOL 600 \OG ]Ft I LOO 0YDC1 Mar seder fore she, IA] I6 THERMAL PARAMETERS tredwas. co offi r indt dthe d aemea4 t %I -Ci •006.;.001 TeegeeMr R MIkee the 6Pstairs AS eeWre f%1°ai 037ff9Wi Teegemlve eemd'ent n the Winer P, 1 %1 °Cl -0,5 +p 0.05 ieBereMrnednleari ha We Dole T%!KI 049'(,002:' leryttdert menlrkm tltYe lPPmndl� CI - 005,/ 0.01 MECHANICAL PARAMETERS B avlght{IhQ ,.- Vinab prcen FnergY Amedaas, Inc. ;,r DlneWeAVIA /N/a /ti she 4. 1011 Subject to Field Inspect - d5Af39.Oj2A rhklmrswlpbeae be 11o1 asa'x'y1ngllwlmAOm Tel: +1(868) 686-8820 sp•anonor,dnauaad lnrrH as °aeee . ° r.r mi wea - d +ugH io] ` 43.7 Joedlm heoetrdMr aegreleMnnralabaw 11 RF s A a a P.,e..usE -z mh: te919w /ursf 47.2/12 xerdlievsE•z VAN lbeMrwlMR � irelu Phq mooed Ina.f rhtllnegnd UV r•p9 O df leIXmO`IP65 catrpequmlMr /teNrrivotnr1Y /wmilall ED t Polveneolnns f 6.14 x. 6.14 OPERATING CONDITIONS win i 0.5 in i 36m SERIONA —A a1, u gUmp mbre,t°W 4dmsa Solar modules are electrical generating Y¢YMa br lrsg w © equipment ,andshouldonlybehandledorins - talled by professional Installers. Read the in- M.r,aeelr e[A 0,. :_ 1v struction manual in its entirety before hand - ' ling, installing, and operating Yingli modules. PACKAGING QUALIFICATIONS & CERTIFICATES I EC61215, IEC61730, 111.1703, Class C Fire Ratlnq, 1509001 a € M yAA APPROVED lialfli lMph /tlett pill C DS CE s B avlght{IhQ ,.- Vinab prcen FnergY Amedaas, Inc. ;,r Subject to Field Inspect �m wmpnana won o.r warranlr Terms ana commons °' � +' '" � � b ® asa'x'y1ngllwlmAOm Tel: +1(868) 686-8820 sp•anonor,dnauaad lnrrH as °aeee . ° r.r mi wea � � n ` t ea'I�id uitdin 'C � www.yinglisdlahcom CONRDDMAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SCLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER JB- 800167 00 MARKET: MODULES YXtA.tui MANAO}JC MOUNTING SYSTEM * SOLARCITY CANOPY -C SUNNY BOY 3000US STORM MARIANN 4120 BALSAM ST. WHEAT RIDGE, CO 80033 3037255812 STORCK RESIDENCE 2.53 KW ROOF MOUNT PV SYSTEM PACE NAME SEAN THIEL .\DesignerSlgnature.Jpg mr, 3055 Clear d. Way REV: DATE San Mateo, CA 94402 P V Q U 5 /6 /ZO�� T:(650) 638 -1028 1 F:(650)638 -1029 (888 )-SOL -=(765 -2489) 1 www.solarcity.com I-V CUVES SUNNY BOY 3000 -US / 3800 -US / 4000 -US UL certified, reliable system managers The Sunny Bey 3000 US, 3800 -US and 4000 -US inverters are specially designed for countries that require UL certification. Automatic grid voltage detection' and an integrated DC disconnect switch simplifies installation, ensuring safety as well as saving time. These models feature galvanic isolation and can be used with all types of modules - crystalline as well as thin -film. The diecost aluminum enclosure, with the OptiCool active temperature management system, guarantees the highest yields passible and a long service life, even under extreme conditions. The Sunny Boy 3800 US is designed for projects with a cur- rent limit of 16A. CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPEC710E SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. US PoIen1111) 52519Bl JOB NUMBER JB -800 SYSTEM: K1j SUNNY BOY 3000US STORCK, MARIANN 4120 BALSAM ST. WHEAT RIDGE, CO 80033 3037255812 Toll Free +1 888 4 SMA USA www.SMA- America.com STORCK RESIDENCE 2.53 KW ROOF MOUNT PV SYSTEM PAGE NAME CUTSHEETS SEAN THIEL \DeslgnerSlgnature. jpg f3! 11417 3055 Oearview Way REV: DAIS San Mateo, G 94402 (� T:(650) 638 -1028 I F:(650) 638 -1029 PV 9 5/6/2011 (888)- SOL- CM(765 -2489) 1 www.solanck Sunny Boy 3000AIS StmyBuy3800A5 SunnYBoy40II "S Terhni mldma : ROBYAC 240VAC '. SdOYAC 208VAC 240 AC' 0 ' C � .y � `i ROY P,2 P� ry C "`c 4,.. 1 2'tt tl <' 5 Lfl " N IRO { 300l 'r „ 4`... ! VS!'4w k.A k..t�.l f y (.?`r.✓ InDm IDq Mrx,m, mmended PV power la made]. STCI 3 75OW 475OW. 4375W 5000 Ms. , DC I f— l® <oay ,III 3200W 4200W: ' =420OW Soov 600Y ? 600V T.SGr..`"Wa. ”' OC nvm vllagv - 250 310V ` 310V -.G_ - MPP 175 -400V 200 400 V; 250 -480.Y 220-480V 250- - - " + a` MIn OC IIg /aa Yllve 17S/328V 200/228V, 2501285V 220/285V 750/285'V �,4 l - 1 ti Mnxdpvl I/p hpel iDCd I L)7p /17A 18A /IgA 14 A I8A 36A ®comb c•daer.i vui 36AC—bireAmr -i-I 36Aoo- IAnedferv.mol 4 Numb. , tMP➢I cken /fu-8 per MPpfrac4n I /410Cd'uconneal SIP r y f yY`rs'+`- Gutput(AC) 3000 W 3800w 3500 W AMD W M AC ,, Ip wer ! 3000 VA 3800YA. 3500VA 4000VA - {?.,. ,a$ tie Nem mlAC Velmgel nd a @oNe 20641• 240 Vf0 - 2dDY /: 20BV /'0 240Y/• - AC ralpgervna. 183 :229V 211 264V. 211 26E !V 1113-229V 211 2"V' + ,ACgrid] pwnryrange 60H959.3 605 IA. :. 60 H459D3- 50,5fir 60 H,c 593 605H. i' _ Mdar. "ympN Cmmnf 13;A 13A 16A , `. 17A Powecbam laoa 91 1 1 ' 1 f PMaew.dvdeo /<vmMie,.pMaea ll2 3/2 I/R C Hom,onu - - +4% <4%i _ q% - Y X' } Efficiency Mv6;�c eery 96gY 965X 9684 963N. 968% V , , CECdFdenq 95.M 95 - 96.1T6 -: 155X 960K Prates on device sevmsepobrnyprolealinn �.'- AC lliod dwn prol<d on when, ly k1 d/ 14pof anesane sae •/ •) •/ 4 2 S_ °�^ 6 P 1 2! d/ ervd6g6 I g ry L f 11111 1 I /111 -- - 11111 �0 11 G ai dat s DEniwv (WjH/Djmin 450/35D/235118/id /91 4 a / /D) nn m. j P ckm9d orelW /H 390/ 5801470115/23/10.51 ' .'11...... '.vr� V+,rs - "'A 2 � - ,,: -v _ DCpNµpiwtl padln8d /HYAlanmm(n] 370 ),2d0 /200J15/91111 Wemb, DC D,aonngaweigtu 38 kg 1114161134kg 18 'PncLeBw•ghl/ DC Onsurmed p6$rv9 wsaM> 4418'19716)/A t (9161 _ 583800- US:NOW AVAILABLE' .:� V opephg lempemtmmmn, 0.9 Pawa) 25 IC. ±4S'C 1 13 113'8 Nga <(.ganbamn lyP wl) ;- 1, AD OfAl L www3MAdokimm 37dBIA) - In1<ma y �mnrvmylron orneht - _ il DI O.1 W'i 01W Topcyygy 11Flmndomar 6wndo6¢er I£Imndom,er Coding aoaeep (op Coal Opreed' !DDBCnn1 Electron ca prated onml n &y vnnea vnnreo NEMA 3R /NEMA 3R ;, REMA DR) NEMA 3R 'NEMA 3R /NEMA 3R Features O'�pkylml ae /gmph'c 8 -' �/- •/ _. ::: •/ _ Intnl- a 65485/ B e Na i :: oyo o/o ` F g o/o Wnm �' IUl )512D -y •JA /O' :' • /Of0' • /ayO r UL CerilRBd Efficient Simple - Cerlfiwt rip tram. vv b6lewrequvAl - Pad i5lCL.kA81,CA2 Nv 16]12001 'ULI741,U499S, IEEE 1547FCC 422 F .4o'�mne3Ta ragogelLt •Qb 114 peak Tfiaency +G'aiv sdam.: •iPaeNed I mc 7pld , NOlE,US ed ahp nl:�y8da <anMcaim'IUl7]41 /IEEF134J7 •(hniCd ml lemPeraum ` - ah 6 ge d•eaona Dom ai wi deep.- ' mwag menlsyslem =.Ilegmed DC decomea swErM iSmRSs dl sres ob'pr Hwrores -Km am'b We - ., -, t' „ , t e aot vn SB3000US %38WUSI0 SBd000US _ SUNNY BOY 3000 -US / 3800 -US / 4000 -US UL certified, reliable system managers The Sunny Bey 3000 US, 3800 -US and 4000 -US inverters are specially designed for countries that require UL certification. Automatic grid voltage detection' and an integrated DC disconnect switch simplifies installation, ensuring safety as well as saving time. These models feature galvanic isolation and can be used with all types of modules - crystalline as well as thin -film. The diecost aluminum enclosure, with the OptiCool active temperature management system, guarantees the highest yields passible and a long service life, even under extreme conditions. The Sunny Boy 3800 US is designed for projects with a cur- rent limit of 16A. CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPEC710E SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. US PoIen1111) 52519Bl JOB NUMBER JB -800 SYSTEM: K1j SUNNY BOY 3000US STORCK, MARIANN 4120 BALSAM ST. WHEAT RIDGE, CO 80033 3037255812 Toll Free +1 888 4 SMA USA www.SMA- America.com STORCK RESIDENCE 2.53 KW ROOF MOUNT PV SYSTEM PAGE NAME CUTSHEETS SEAN THIEL \DeslgnerSlgnature. jpg f3! 11417 3055 Oearview Way REV: DAIS San Mateo, G 94402 (� T:(650) 638 -1028 I F:(650) 638 -1029 PV 9 5/6/2011 (888)- SOL- CM(765 -2489) 1 www.solanck MOUNTING HARDWARE :MM RESIDENTIAL SOLAR MOUNTING SYSTEM Canopy is the strong, safe, waterproof mounting system for structurally attaching solar panels to composition shingle and wood shake roofs. A715 grade 50 high strength structural steel with durable corrosion resistant coating provides more strength than aluminum and better corrosion resistance . than stainless steel. Bracket - style attachment allows for shingle (lashings to completely cover penetrations, providing excellent long -term waterproofing. • Precision engibeered brackel geometry pmddesetrintit uplift resistance of any mounting bmeket. Rated to 5001MS, • A715 grade 50 high strength structural steel prohdes Brit slos,11h than almnimar. • Pro., 71, r ennoeJ,,n resistant hnt- dip 2.1. ized coatme. l abalamly tests show es efb' leas berms "sn"in, nsslslanse tlgn common stainless steel • Shinglostyle flashing cumpletcly covers penetration, Providing better long term Teak protection than neoprene cone hashing, IS Sh i ngle Flashing locks in place for best water proofing py 2x W16 lag bolts e ® 2x5 /16 flat washer yaa Canopy root precision engineered mounting bracket ag c ®� °nC ®Or ' 't� 888 -SOL -CITY 1 888 - 765 -2489 1 WWW.SOLARCITY.COM APPROVED INSTALLATION METHOD • Runts (brackets) are to be mounted no further Il,ar, fl "apart • Rollers must be located. Pilot hales most be drilled into the center of ratters . • shingle course immediately almve mortration shall be cut using provided template to accommodate flashing. • Laval wind conditions, aras, um, root angle, and position of array on mof will determine dengo wind pressure. Standard insellalion of Canopy applies when design wind pressures are found to be 28ps1 or lower and requires one 2Vh -inch lag boll in the primary position. For a8 other cases, see chart to tight. • Flashing is to be inserted under rnurse of shingles above penetration and pressed down over root until it snaps into place. • Ran is atGCbed with all locking dairy.. Flashing Lags and Washers Root- Bracket Root - Bracket install IS Flashing installed Rail installed go 8'OC Max 6 Roof rafter ® Ran l APPROVED Subject to Field Inspections Wheat Ridge Building a t. Date.q� v Plan Checker :° 43019 �,° U -Z•It, CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ORGANIZATION, TION, EXCEPT IN CONNECTION BENEFIT OF ANYONE EXCEPT SOLARCITY INC., PART TO THE RECI IN J WIT WIT H THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, VAHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER J B- 800167 OO PREMISE OWIER. AHd wheat Ridge OESCRIPRON: STORM MARIANN STORCK RESIDENCE 4120 BALSAM ST. 2.53 KW ROOF MOUNT PV SYSTEM WHEAT RIDGE CO 80033 * PAGE NAME 3037255812 CUTSHEETS DESIGN: SEAN THIEL �- air ��� ° '" 'SolarCity MARKET: REST MODULES 11 YINGLI YL230P -29b ADeslgnerSlgnaturejIgg 1 PROIECTMANAGEk * M DUNIING SYSTEM: SOLARCITY CANOPY -C 3055 chanstiew Way teo, San Ma CA 94402 T:(650) 638 -1028 1 F:(650) 638 -1029 (888)- SOL {TTY(765 -2489) 1 www.mlarcity.com SHEET: REV. DATE PV 10 5 / s / zOii PAYMENT TYPE LEASE IN TER' t' SMA # SUNNY BOY 3000US inm oast a :m 15 y. 11 r, rere, n+*nel .no mmMnm Ls pn,euanonr ne, w.I. -par 1119, ro m.11111W UIlwaeltoASCe 7-05. C AUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 4120 BALSAM ST. WHEAT RIDGE, CO 80033 FRONT OF HOME INVERTER & X DC DISCONNECT X UTILITY SERVICE O x SOLAR PHOTOVOLTAIC ON ROOF PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240 V MAX CURRENT = 16 A APPROVED Subject to Field Inspections Wheat Ridge Building Peft Date.q .q.. i) Signed......... Plan Checker CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE OF ANYONE EXCEPT INC., NOR SMALL NOR SHALL IT BE OE IN MOLE OR IN PART TO OTHERS OUTSIDE UTSIDE THE IN HE RECIPIENTS ORG THE SALE AND AND EXCEPT IN CONNECTION N17H THE USE HE THE WRITTEN SOLARgTY EQ TTHOUT UT THE MRITIEN PERMISSION OF F SOLAR, SOLARgtt INC. JOB NUMBER JB- 800167 00 PREMISE OMNER: NU Wheat Ridge DESCRIPTION: STORCK, MARIANN STORCK RESIDENCE 4120 BALSAM ST. 2.53 KW ROOF MOUNT PV SYSTEM WHEAT RIDGE, CO 80033 * PACE NAME 3037255812 SITE PLAN PLACARD DESIGN: SEAN THIEL lid ��.r ,I �- •, S 'f' MARK RE ST MODULES: 11 Y NGLI YL230P -29b ADesignerSIgnature,JPg PROJECT MANAGER: * MDUNRNO SYSTEM: SOLARCITY CANOPY —C 3655 a CA 999 Way San Mateo, w, CA 02 - OL QTY )638 -1028 F:(66o 29 (888 } mlarsOL (765 -2989) wmwwcity.com SHEEP: REV: DATE PV 11 5/6/2011 PA YMENT LEASE )N 1 S MA # SUNNY BOY 3000US I `. ISSUED: 05/03/2010 T .':EXPIRES.: 10/30/2010 22 sqs of 30# .felt & 30 yr Dimens shingles. s. Storck ke Aberle 02 -1956 A &H "'Roofing, LLC USE: UA tBLOCK /LOT #: 0/ ESTIMATED 'PROJECT EVALUATION: 5,136.00 FEES 181.10 .00 pF 110.45 291.55 uired. Ice dam membrane is required from eave edge to Board sheathing with any gap greater than 1/2" verlay on entire roof. Sheathing inspection is .:Midroof- inspection is not required on permits ontractor - shall provide ladder for inspections.': cannot be performed due to inclement weather must be n.` on the day of inspection or a're-inspection fee istances proposed by this permit application .:are accurate, and do not violate applicable the City of Wheat Ridge or covenants, easements or restrictions of record; that all made are accurate; that I have read and agree to abide.. by all conditions printed on this -esponsibility for compliance With the Wheat 'Ridge Building Code (I.B.C) and all other - or work under this permit. Plans 'subject to field inspection. 3 — date mce with the provisions set forth': in your application and is subject to the laws of the ng Regulations and Building Codes of Wheat 'Ridge, Colorado or any other applicable from the issue date. .Requests for an extension must be received prior to expiration :d at the discretion of the Building Official. mit may be acquired for a fee of one-half the amount normally required, provided no .in the original plans and specifications and any suspension or abandonment: has not =s have been or if suspension or abandonment :exceeds one (1) year, full fees f. shall me that will change the natural flow of water causing a drainage problem. ling Inspector twenty-four (24) hours in advance for all inspections and shall receive'. ird before proceeding with successive phases of the job'. Lpproval of drawings and specifications shall not be construed to be a permit for, nor the provisions of the building codes or any:. other ordinance, law, '. rule or regulation. ld inspections. date 30.3)234 -5933 BUILDING OFFICE:: (303)235-2855 ?M ANY BUSINESS 'DAY FOR INSPECTION THE ':FOLLOWING BUSINESS DAY.'.. City of Wheat R ogic COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application property Address; Property Owner (plez Mailing Address: (if different than property address) Address: Contrac #or: Contractors City License #: 6102 - /FS (f Sub;Cpnt Electrical: Plumbing: Phone: Date: Plan # Permit # Mechanical: City License # City License # City License # Descrtptlon.ofwar k S / 7- I �ZZ GG /� / CAS �� C / S Contrac Value: Review Fee (due at time of submittal): Squares a BTU's Gallons Amps Sq Ft. $ OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; thatI am the legal owner or have been authorized by the legal . owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. - CIRCLEONE: (OWNER) (CONTRACTOR) ar (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: /C''/1'l. #G. R Hsi A /✓ SIGNATU r , - �Iw� DAT E: !x C p CC c� •, ..., � , ' /r r � . �� � � I]LPAR7�/..I�Tj� 0� �.:s 3 NSk�yv°` ✓i �d� y « 3 �i � � n� k � .a;'lfl�11NG FlRE oI=PARTngeNr- <❑ approvers w/ rA meats disapproved o na reuiew,reSltred�„� Bldg Valuation: T � � ''� INSP C ION R ORS INSPECTION REQUEST LINE: (303) 234-593 Occupancy/Type Electrical Inspections will not be performed unless this card is posted on the projec s' e. Call the inspection request line before 11:59 p.m. to receive an inspection the following business a . Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Mid -Roof Concrete Encased Ground (CEG) Foundation / P.E. Letter Lath / Wall Tie Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Comments Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Z l'7 Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. "For Inspection Time Window — Please email insptimerequest@CI.Witeatridge.Co.US by 8:00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge it R-Adential Roofing PERMIT - 201701573 PERMIT ,11:- 01701573 ISSUED: 06/06/2017 JOB ADDA3F)S 120 Balsam ST EXPIRES: 06/06/2018 JOB DESCR ION: bedeck and reoof with Tamko Dimensional shingles - 28.88 squares *** CC _-ACTS *** OWNER (303)725-5812 STORCK MARIANN SUB (303)842-8484 Gerald Nunes & Perfecto Aragon 170171 Colorado Builders Corp. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,422.16 FEES Total Valuation 0.00 Use Tax 155.87 Permit Fee 172.60 ** TOTAL ** 328.47 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installatir- -f r^ -f sheathing (new or overlay) requires an approved inspection prior to installatio; roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€ms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection.