Loading...
HomeMy WebLinkAbout4660 Balsam StreetCity of Wheat Ridge `ra Residential Solar PERMIT - 201801000 PERMIT NO: 201801000 ISSUED: 04/20/2018 JOB ADDRESS: 4660 Balsam ST EXPIRES: 04/20/2019 JOB DESCRIPTION: Installation of roof mounted solar panels, system size 6.380 KW, solar PV. *** CONTACTS *** OWNER (303)940-5955 BREINER JAMES K SR SUB Cody Oram 170190 Vivint Solar Development LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 14,036.00 FEES Total Valuation 0.00 Res Solar Review 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by in signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this penmtt. I further attest that I am legally authorized to include alI entities named within this document as parnes to the work to be performed a tt at all-ivor��p rformed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER - or CONTRACTOR (Circle one) Date 1. This permit was issued based orrthe-information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting ofq permit shall not be construed to be a permit for or an approval of, any violation of any provision of any applicable code or any ordi a or regulation of this jurisdiction. Approval of work is subject to field inspection. Pr Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat R dg� COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(a)-ci.wheatridge.co.us FOR OFFICE USE ONLY Date: I ///6 f/6 r Plan/Permit # / (d Plan Review Fee: U Building Permit Application *"* Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. **' Property Address: 06 '?nws T V Property Owner (please print): TaM2s ! rel e F Phone: Property Owner Email: Mailing Address: (if different than property address) Address: , State, Zi Architect/Engineer: JO(O P. b_�_Ar J Architect/Engineer E-mail: I o;&I • t'�axj E�'y: ��`ti fso�c�r, ccs+ Phone: Contractor: Vitt wso/car- Contractors o/carContractors City License #: _ / �_'TO 12 Q Phone: ^3�/67- 02 g6 Contractor E-mail Address: 6 U.Sin163kc,eRSi to v;y , n�i CnM For Plan Review Questions & Comments (please print): CONTACT NAME (please print): 70e3 Fee k(agi f 2 i? Phone: CONTACT EMAIL(p/ease print): odes; r e_e `���_ V;+llld SG/ar% Co Sub Contractors: Electrical: RECEOumbing: Mechanical: W.R. City License # I V.R. City License # W.R. City License # APR 1 0 2018 Other City Licensed Sub: Other City Licensed Sub: City License # pp City License r Complete all information on BOTH sides of this form ❑ COMMERCIAL a RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT Y3 OTHER (Describe) Soles r 1;E --1i1 (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) -f 000 I /'-O L iecJ Sq. Ft./LF Amps Btu's Gallons Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) /V 03 1p OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. _ ,-- — 1 \--- CIRCLE ONE: (OWNER) (CONTRACT R) or AUTHORIZED REPRESENTATIVE) Of (OWNER,'' (CONTRACTOR) Signature (first and last name): DATE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $. W AV O i it Structural Group J. Matthew Walsh, SE, PE Senior Structural Engineering Manager James.walshOa vivintsolar.com March 28, 2018 Revised March 28, 2018 Re: Structural Engineering Services Breiner Residence 4660 Balsam St, Wheat Ridge, CO S-5886125; CO -01 To Whom It May Concern: 1800 W Ashton Blvd. Lehi, UT 84043 Jon P. Ward, SE, PE Structural Engineering Manager ion. ward@vivintsolar.com We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence is typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Hem -Fir (North) #2 or better with standard construction components and consists of the following: • Roof Section: Dimensional lumber - 2x6 at 24" on center with purlin supports 4.5' from the ridge and 1x6 collar ties at 48" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. • Roof Section: Dimensional lumber - 2x6 at 24" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. B. Loading Criteria 8.49 PSF = Dead Load (roofing/framing) 2.59 PSF = Dead Load (solar panels/mounting hardware) 11.08 PSF = Total Dead Load �rQ c� Sa` 20 PSF = Roof Live Load 34 PSF = Ground Snow Load (based on local requirements) Wind speed of 115 mph (based on Exposure Category B - the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "EcoFasten Solar Installation Manual", which can be found on the EcoFasten Solar website (www.ecofastensolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non -uniformly, our office should be notified before proceeding with the installation. Page 1 of 2 VIVIII TC Page 2 of 2 2. The solar panels are 11/2' thick and mounted 41/2' off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6" above the existing plane of the roof. 3. Maximum allowable pullout per lag screw (5/16" x 41/2") is 235 lbs/inch of penetration as identified in the National Design Specifications (NDS) of timber construction specifications for Hem -Fir (North). Based on our evaluation, the pullout value, utilizing a penetration depth of 21/2", is less than the maximum allowable per connection and therefore is adequate. 4. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. The following values have been verified by in- house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections shall be staggered to distribute load to adjacent members. D. Summary Based on the above evaluation, with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation is in conformance with the 2015 International Residential Code, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, Jon P. Ward, SE, PE CO License No. 52115 Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 72 72 72 48 48 48 Max Uplift Load Ibs 198 163 154 335 275 260 D. Summary Based on the above evaluation, with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation is in conformance with the 2015 International Residential Code, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, Jon P. Ward, SE, PE CO License No. 52115 n LJ ROCK -IT SYSTem Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest to install, most secure and cost- effective solutions for installers. EcoFasten offers a wide variety of standard products as well as custom solutions, for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented conical sealing system has been in service in the snow guard and solar industry for two decades. FeaTures • Fastest, easiest to level system on the market • ETL listed to UL SUB 2703 • Class A Fire rating with Type 1 modules • Integrated electrical bonding SYSTem comPonenTS ROCK -IT MOunT Array sKlrT • SIMPLE- only 3 components • Fixed wire management tray • North-South adjustability of up to 4" • Only one tool required (1 /2" deep well socket) kyr ROCK -IT COUPUnG A ,,Q®EcoFasten Solar V EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 ROCK -IT MOl.. nT ASSeI'1'1BLY NOTe: ITems 1-11 SHIP assemBLeD 1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS 2 Rock -It Mid -Clamp 6005A -T5 3 Compression Spring 300 Series SS 4 Tie Plate 6005A -T5 AL 5 Rock -It Shelf 6005A -T5 AL 6 Flange Level Nut 300 Series SS 7 Packaging O -Ring (Remove Prior to Installation) 8 Rock -It Pedestal 6005A -T5 AL 9 3/8" ID Star Lock Washer 300 Series SS 10 3/8"-16 Hex Tap Bolt 300 Series SS 11 5/16"-18 x .375" Hex Flange Bolt 300 Series SS 12 Rock -It -Slide 6005A -T5 AL 13 5/16" ID EPDM Bonded Washer 300 Series SS 14 5/16" x 4" Hex Lag Screw or 5/16"-18 X 1.50" Hex Bolt 300 Series SS ROCK -IT COUPUnG ASSeI"1'1BLJ- NOTe: ITems 1-4 SHIP assemBLeD 1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS 2 Rock -It Coupling Mid Clamp 6005A -T5 AL 3 Compression Spring 300 Series SS 4 Rock -It Coupling Shelf 6005A -T5 AL www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 Array LaYOUT • Find the required structural attachment points. Mark these using a vertical (N -S) chalk line on the center of the rafters. Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser bracket spacing in the E -W axis vs. the maximum spacing. Max spacing is 48" for portrait orientation and 72" for landscape orientation. Consult project layout diagram for project specific bracket spacing on the roof. Install Rock -It Mounts to predetermined mount spacing. The array skirt sections are the width of a typical 60 cell module - use the array skirt as a guide to lay out module placement. Note: The distance between the rows of mounts is calculated by the module dimension N -S plus 1 3/8" (35mm). Lag screw should be installed as close to center of exposed shingle as possible. GreenFasTen FLaSHInG InSTaLL 1 Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2 Drill a pilot hole (1 /4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3 Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when torqued. 4 Line up pilot hole with GreenFasten flashing hole. Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed hole in the flashing and into the rafter. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 ROCK -IT SYSTem inSTaLL ROCK -IT SYSTEM - Install Eco Fasten Solar Flashing with Rock -It Mounts Follow GreenFasten Install instructions for flashing and bracket install on composition shingle roofs. Optimum vertical distance between lag bolts is 13/8" plus module dimension. Set mounts on eave most row so that the Rock -It Pedestal is on the South end of Rock -It Slide. (ex. image 1) Set mounts on all upper rows so that the Rock -It Pedestal is on the North end of Rock -It Slide. (ex. image 6) 2 Install Array Skirt to Eave Mounts • Install array skirt starting on west side of array and move east. Attach Couplings to Array Skirt 3-4 Tighten the west most array skirt bolt on coupling first. When tightening the east bolt the array skirt sections will be drawn together. 5 Align and Straighten First Row of the Rock -It System with Array Skirt Use North-South adjustment of the Rock -It pedestal to straighten array skirt. Tighten screw on side of Rock -It Pedestal to secure it to the Rock -It Slide. Adjust Flange Level Nut to level the system (optional - can be leveled during or after installation) 6_7 Install 1 st Row of PV Modules Slide Rock -It Mounts that are upslope down to engage top of first module. Note: Make sure cable tray is facing upslope. Torque 1 st and 2nd row of mid -clamps on Rock -It Mounts and Rock -It Couplings to 150 in -lbs. Note: Torque setting may vary according to module manufacturer. Install Balance of PV Modules $_9 Secure wire and electrical components in built in wire tray on Rock -It Mounts and Couplings. Install next row of panels and torque mid -clamps to secure modules. Repeat install for all remaining rows of modules. 10 Level the Rock -It System • When assembly is complete, level the entire system by adjusting Flange Level Nuts. www.ecofastensoIar.com info@ecofastensolar.com 877-859-3947 GrounDinG LUG insTaLL x ; rill Necessary Components: Burndy CL50-1TN Ground Lug (UL Listing #KDER.E9999) 14 AWG - 4 AWG Copper Ground Wire 8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS) - 8-32 Serrated Flange Nut (300 Series SS) 11 /32" and 1/4" wrenches or ratchets/sockets 1 The Ground Lug is installed into the T slot on the Rock -It Mount. 2 Slide the Flange Head Bolt on the Ground Lug into T slot on Rock -It Mount. 3 Tighten Flange Nut/Bolt. 4 Place wire in Ground Lug channel and tighten set screw to complete assembly. BonDinG AssemBLY anD BonDinG PATH - Bond Path I Grounding lug — Equipment Grounding Conductor (EGC)- generally to earth ground Rock -It Coupling Rock -it Mount Integrated Bonding www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 THermaL EXPansion anD BonDInG A thermal expansion gap is required per each continuous 100' length of modules. Omit a coupling and leave a 2" gap in the array skirt and also between the modules at that point. BracKeT sPacinG Portrait Orientation Maximum bracket spacing in Portrait orientation is 48" OC. e..s,a Bond Path Grounding Lug Equipment Grounding Conductor(EGC} generally to earth ground Rock -it Coupling • Rock -it Mount Landscape Orientation Maximum bracket spacing in landscape orientation is 72" OC. Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser spacing E -W than the maximum. sTaGGereD LAYOUT I canTlLever ante oFFseT Staggered Mounting Points ■ Rock -It Mount =Rock -It Coupling The array layout instructions in this installation manual offer a general overview of layout. Periodically, due to a variety of factors (roof obstacles, shading, etc.) other layouts are required www.ecofastensolar.com Cantilever: Maximum cantilever is 1/3 bracket spacing. For portrait orientation installations, check layout prior to installing. Offset: Offset from all roof edges depends on wind speed, snow loads, local fire and building codes per location info@ecofastensolar.com 877-859-3947 ROCK -IT SYSTem • Fastest, easiest to level system on the market • ETL listed to UL SUB 2703 • Class A Fire rating with Type 1 modules Integrated electrical bonding • SIMPLE- only 3 components • Fixed wire management tray • North-South adjustability of up to 4" • Only one tool required (1 /2" deep well socket) Max No. of Panels 300 Modules per ground lug Materials 300 Series Stainless, 6000 Series Aluminum Max System Voltage 1000VDC Coating Black Andodization/Mill Finish Class A Fire Rating With UL1703 Type 1 Rated Modules Lug Specifications Burndy CL50-1TN Ground Lug (UL Listing #KDER E9999) Leveling Range 3-4" Ground Wire Per above Lug spec. 14 AWG- 4 AWG Copper Ground Wire Rock -it Slide Range 4" Max Module Size 64.96"(1650mm) x 39.05"(992mm) x 2"(50mm) Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45 PSF Max Anchor Spacing 72" Rock -It Mount Load Rating 547lbs with Single 5/16" Lag 3.0 Safety Factor Skirt Box QTY 6 units Slide Fastening Hole 5/16" diameter Mount Box QTY 12 units Module Cantilever Lesser of 25% Width, or Module Installation Manual Rock -It Slide Box QTY 50 units Coupling Box QTY 12 units Warranty 10 Year Material and Workman- ship Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC Standards: UL 2703, UL 1703 `NTERTEA. us ISTEL www.ecofastensoIar.com T =EcoFasten Solar V - info@ecofastensolar.com 877-859-3947 0 www.jinkosolar.com nn1<0 o • IS09001:2008 Quality Standards + IS014001:2004 Environmental Standards • OHSAS18001 Occupational Health R Safety Standards C@us wn,• LISTED �_ ___ CE 8 c° a° 0 E t7 KEYFEATURES 4 usbar Solar Cell: b r 4 usbasolar cell adopts new technology to improve the efficiency of modules , offers a better aesthetic appearance, making it perfect for rooftop installation. OHigh Efficiency: Higher module conversion efficiency(up to 18.33%) benefit from Passivated °0X FJSON Emmiter Rear Contact (PERC) technology. Anti -PID Guarantee: Limited power degradation of Eagle module caused by PID effect is guaranteed under 60085% RH condition for mass production. i•1 Low -light Performance: Advanced glass and solar cell surface texturing allow for excellent performance in low -light environments. JIM Severe Weather Resilience: g �Pa- Certified to withstand: wind load (2400 Pascal) and snow load (5400 Pascal). JDurability against extreme environmental conditions: High salt mist and ammonia resistance certified by TUV NORD. 10 Year Product Warranty • 25 Year Linear Power Warranty 100% W linear performance warranty 97% gdditl Ue Standard performance warranty ss% °nava! � 90% m JrnkO Solar'066�_ 50.2% 1 5 years 25 Front t 1 Side Packaging Configurations I Two boxes =One pallet } 25pcs/ box, 50pcs/pallet, 700 pcs/40'HQ Container Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) open -circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature(C) Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Back Current-Vottage & Power -Voltage Curves (290W) aa0 � 250 E 2ao t5a £ too � 50 Z 0 0 5 10 15 20 25 M M 40 Voltage (V) Temperature Dependence of ISC,Voc,Pmax W -25 0 25 50 25 100 Cell Temperature('q Cell Type Mono -crystalline PERC 156x156mm (6 inch) No.of cells 60 (6x 10) Dimensions 1650x992x40mm (64.97x39.06xl.57 inch) Weight 19.0 kg (41.9 lbs.) STC NOCT 3.2mm, High Transmission, Low Iron, Front Glass AR Coating Tempered Glass Frame Anodized Aluminium Alloy Junction Box IP67 Rated Output Cables 12 AWG, Length:900mm (35.43 inch) Fire Type Type 1 JKM280M JKM285M JKM290M JKM295M JKM300M STC NOCT STC NOCT SFC NOCT STC NOCT STC NOCT 280Wp 209Wp 285Wp 212Wp 29OWp 216Wp 295Wp 220Wp 30OWp 224Wp 31.8V 29.8V 32.OV 30.OV 32.2V 30.2V 32AV 30AV 32.6V 30.6V 8.81A 7.01A 8.91A 7.07A 9.02A 7.15A 9AIIA 7.24A 9.21A 7.32A 39.OV 36.2V 39.3V 36.4V 39.5V 36.6V 39.7V 36.8V 40.1V 37.OV 9.43A 7.62A 9.50A 7.72A 9.55A 7.81A 9.61A 7.89A 9.72A 8.01A 17.11% 17.41% 17.72% 18.02% 18.33% -40°C-+85*C 1000VDC(UL) 15A 0-+3% -0.39%/°C -0.29%PC 0.05%/°C 45±2"C STC: ' Irradiance 1000W/ml Cell Temperature 25°C AM=1.5 NOCT: irradiance 80OW/mz $ Ambient Temperature 20°C AM=1.5 Wind Speed 1m/s * Power measurement tolerance: ± 3% CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Q Jinko Solar Co... Ltd. All rights reserved specifications included in this datasheet are subject to change without notice. US -MKT -300M v1.0 rev2016 solar=ee SolarEdge Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US Is G A �Ipl­, 4 -JSA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS -UK -ISRAEL -TURKEY -SOUTH AFRICA -BULGARIA www.sofaredge.us so I a r' • • Single Phase Inverters for North America SE300OH-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US =E300pH�U5 �SE3800H-US SESOOOH-US_LSE6000H-US SE7600H-US 4650 5900 1 7750 1 9300 OUTPUT W Transformer -less, Ungrounded Rated AC Power Output 3000 3800 5000 6000 I 7600 VA Max. AC Power Output 3000 3800 5000 ! 6000 7600 VA AC Output Voltage Min: Nom: Max. (1.8.3.- 208.-.229) - ✓ Vac i AC Output Voltage Min. -Nom. -Max. (211 -.240..- 264) ✓ ✓ l ✓ ✓ j ✓ Vac AC Frequency (Nominal) f 59.3 - 60 - 60.5111 Hz .. Maximum Continuous Output Current 208V _. .. Maximum Input Current 240V 24 - 8.5 I 10 5 13 5 16.5 A Maximum Continuous Output Current 240V 12.5 I 16 21 25 32 A GFDI Threshold1 ... ..... ...... ........................... ....._.. _. .. .. ........._. _ . A _....._................._..._. Utility Monitoring, Islanding Protection, ........... Yes Country Configurable Thresholds 1�1 For other regional settings please contact SolarEdge support _................ ........................................ MaximuminverterEfficiency Maximum DC Power 1 4650 5900 1 7750 1 9300 i 11800 W Transformer -less, Ungrounded Yes . .... .. .. .AC DC Input Conduit Size / # of Strings / AWG Range Maximum In p ut Volta ga 480 ............... Dimensions with Safety Switch (HxWxD) Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V 15.5 .. ..... Noise Adc _. .. Maximum Input Current 240V .. - 8.5 I 10 5 13 5 16.5 20 Adc Max. Input Short Circuit Current 45 Oprating Temperature Range e ...... Adc Reverse -Polarity Protection _. - _._......_......_...... .._......... ........_._-. ... ..- Yes .. ........... Ground -Fault Isolation Detection 600ks Sensitivity ..... ................ .. ........... ...... - 1�1 For other regional settings please contact SolarEdge support _................ ........................................ MaximuminverterEfficiency 1�1 Revenue grade inverter P/N: SExxxxH-US000NNQ PSI . 99.2 ...... ...... _ ......... .....%...... CEC Weighted Efficiency99 ............... .......................................... ........ .... .. .. .. ...... Nighttime Power Consumption < 2.5 1 W Supported Communication Interfaces I RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 1 Optional121 Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE — Safety.UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 ............. .. ......... ... ................. ....... ........ Grid Connection Standards IEEE1547, Rule 21131, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range ..... . ........... 0.75-1" Conduit / 14-6 AWG . .... .. .. .AC DC Input Conduit Size / # of Strings / AWG Range 0 75 1' Conduit /1 2 strings / 14-6 AWG ............... Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174in / mm Weight with Safety Switch25.3 . . / 11.5 . _ Ib / kg .. ..... Noise I < 25, ....... ..... ... _ .. .. - clBA . . Cooling.... ............... Natural Convection Oprating Temperature Range e ...... 1 13 to +140 / -25 to +601") (-40`F / 40`C option)1s1 F / `C Protection Rating I NEMA 3R (Inverter with Safety Switch) 1�1 For other regional settings please contact SolarEdge support 1�1 Revenue grade inverter P/N: SExxxxH-US000NNQ 131 Pending certification 141 Power de -rating from SOY 151-00 version P/N: SEx H-USOOONNU4 solar =@@ SolarEdge Power Optimizer Module Add -On For North America M M =6A -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK-ISRAEL-TURKEY -SOUTH AFRICA -BULGARIA -INDIA www.soiaredge.us so I a r" • • ! SolarEdge Power Optimizer Module Add -On for North America Rated Input DC Power°1 ...... ... ...I .................... Absolute Maximum Input Voltage (Voc at lowest temperature) ... .................. MPPT Operating Range Maximum Short Circuit Current (isc) Maximum DC Input Current ................................ ....... ..... Maximum Efficiency ... _..... ......... ....... .... .... .... Weighted Efficiency Overvoltage Category P300 / P320 / P370 / P400 / P405 P300 P320 P370 P400 ( P405 (for higher -power (for 60 -cell mod- (for high-power 60 and (for 72 & 96 -cell (for thin film 72 -cell ? uses) 60 -cell modules) I � modules) � modules) � OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) modu es) Maximum Output Voltage 60 I 85 ? Vdc DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 370 400-- 405 W 300 320 _. _.... 48 t 60 80 125 Vdc ................. 8-48 8-60 8-80 1 12.5-105 Vdc 10..... 11 Maximum Allowed System Voltage .... ._ ..... 10.1 Adc 12.5 13.75 ................. 12.63 I Adc mm/in 99.5% - ... 630/1.4 750 / 1.7 845 / 1.9 .. ........... ....... . ......... _........................................ ......................................................................... ....... I ...... .................. 98.8 I I %_.... OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 I 85 ? Vdc DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) -OUTPUT Safety Output Voltage per Power 1 Vdc Optimizer ... _.................................... STANDARD COMPLIANCE EMC . FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 .. ... ..... .... .... ............ 25 Safe IEC62109-1 (class 11 tyafeUL1741 ROHS Yes Maximum Power per String5250 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage .... ._ ..... 1000 ............... .......I..-................................................................. ............. Vdc .......p .................... _. Compatible inverters ....... A11 SolarEdge Singie Phase and Three Phase inverters ................. . Dime nsions(WxLxH) ..... 128x152x35/ 128x152x50/ 128x152x27.5/5x5.97x1.08 5x5.97x1.37 Sx5.97x1.96 mm/in Weight (including cables) 630/1.4 750 / 1.7 845 / 1.9 .. ........... ....... . gr / Ib Input Connector MC4 Compatible AmMC4 / MC4 Compatible phenol....AH4 j Double Insulated; Output Wire Type / Connector Double Insulated; MC4 Compatible I MC4 / Double Insulated; MC4 Compatible Amphenol AH4 ................................................... .............. _......_................................ Output Wire Length ............................................ 0.95/3.0 ............................................... 1.2/3.9 ................................ . m / ft.... ........................ _..... ..Operating Temperature Ran ge..........................................I..........-40+85/-40 ................. - +185 C. F Protection Rating IP68 / NEMASP ................................. ............. ........... Relative Humidity0-100 ............................................... ............................................................................. . .................. ... %._,,. R) Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE A SOLAREDGE INVERTER(')(" HD -WAVE Minimum String Length 8 (Power Optimizers) ....................... ... _.................................... Maximum String Length 25 (Power Optimizers) ;. Maximum Power per String5250 5700 (6 000 with SE760OH. US) ....... ................. .............................................. Parallel Strings of Different Lengths ? Yes or Orientations .............I ........ ............................. ............... ...................... ... ... ..... I'1 For detailed string w ng sizing information refer to: http://ww.solaredge.com/sites/default/fifes/string_sizing_na.pdf. 131 It is not allowed to mix P405 with P300/P370/P400/P600/P700 in one string. THREE PHASE 208V THREE PHASE 480V iMPORTANTSAFETVINSTRUCTIONS solar- o .o - The inverter input and output circuits are isolated from the enclosure. This system does not include an isolation transformer and should be installed with an ungrounded PV array in accordance with the requirements of NEC Articles 690.35 and 690.43 National Electric Code, ANSI/NEPA 70, 2011 (and Canadian Electrical Code, Part I, for installations in Canada). Equipment grounding is the responsibility of the installer and must be performed in accordance with all applicable Local and National Codes. Les circuits d'entree at de sortie de Ponduleursont isoles de 1'enveloppe. Ce systeme n'inclut pas d7solation gatvanique (transformateur) at devra etre installs sans mise a la terre du champ PV et an accord avec les articles 690.35 at 690.43 du National Electric Code (NEC), ANSI/NFPA 70, 2011 (et du Code Electrique Canadian, Partie 1, pour les installations faites au Canada). La mise a la tern- des equipements est la responsabilite de l'installateur et doit etre faite an accord avec /as toutes les regles locales at nationales applicables. The inverter must be connected to a dedicated AC branch circuit with a maximum Overcurrent L • Protection Device (OCPD) of 40 A. Les onduleurs doivent etre connectes a un branchement AC dedie avec un disjoncteurde 40A AThis unit must be operated under the specified operating specifications, as described in the latest technical specification datasheet provided with the unit Cette unite dolt etre utilisee selon les specifications de fonctionnement, comme decrit dans la demiere fiche technique des specifications, disponible surae site web de SolarEdge, http://www.solaredge.us/groups/us/products/overview. HEAVY OBJECT. To avoid muscle strain or back injury, use proper lifting techniques, and if required - a lifting aid when removing or replacing. Objet lourd. Poureviterla fatigue musculaire ou des blessures au dos, utilisez des techniques de levage appropriees at, si necessaire - un auxiliaire de levage tors du retrait ou du remplacement. `C1• only copper conductors rated for a minimum of 75°C/167°F. �1 • \�\ This inverter is provided with an IMI (Isolation Monitor Interrupter) for ground fault protection. • The symbol O appears at grounding points on the SolarEdge equipment. This symbol is also used in this manual. re SolarEdge HD -Wave Inverter Installation Guide MAN -01-00306-1.0 IIIIII9111111EIIII�IIII�IIIIIVYII solar, - ©�;. HD -Wave Inverter Technical Specifications - North America 1 For other regional settings please con tad SolarEdge support SolarEdge HD -Wave Inverter Specifications North America MAN -01-00308-1.0 SE3000H-US SE380OH-US SE5000H-US SE6000H-US SE7600H-US Unit OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA Max AC Power Output 3000 3800 5000 6000 7600 VA AC Output Voltage Min. -Nom. -Max -(l 83 - 208 - 229) - - ✓ Vac AC Output Voltage Min. -Nom. -Max. (211 - 240 - 264) ✓ ✓ ✓ ✓ ✓ Vac AC Frequency (Nominal) 59.3 - 60 - 60.51 Hz Maximum Continuous Output Current 208V - - 24 - - A Maximum Continuous Output Current 240V 12.5 16 21 25 32 A Max. output fault current and duration @i 208V - - 26/20 - - A/ ms Max. output fault current and duration @240V 14/20 17.5/20 23/20 27.5/20 40/20 A/ ms Inrush current AC (Peak/Duration) 2.8/20 Aac(rms) / ms Max. output overcurrent protection 40 A Power factor range 1 (adjustable from -0.9 to+0.9) Total harmonic distortion <3% GFDI Threshold 1 A 1 For other regional settings please con tad SolarEdge support SolarEdge HD -Wave Inverter Specifications North America MAN -01-00308-1.0 HD -Wave Inverter Technical lar' o SolarEdge HD -Wave Inverter Specifications North America MAN -01-00308-1.0 SE3000H-US SE3800H-US SE500OH-US SE6000H-US SE7600H-US Unit Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power 4650 5900 7750 9300 11800 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 15.5 - Adc Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600 kil Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (Optional) Revenue Grade Data Optional -ANSI C12.20 class 0.5 compliant Rapid Shutdown - NEC 2014 690.12 Automatic Rapid Shutdown SolarEdge HD -Wave Inverter Specifications North America MAN -01-00308-1.0 HD-Wove Inverter Technical Specifications Solar" ty a 1 Power de -rating from 50'C SolarEdge HD -Wave Inverter Specifications North America MAN -01-00308-1.0 SE3000H-US I SE3800H-US I SE5000H-US I SE6000H-US I SE7600H-US I Unit STANDARD COMPLIANCE Safety UL1741, UL1699B, C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule14 (HI) Emissions FCC partl5 class B RoHS Yes INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 0.75-1" Conduit / 14-6 AWG AC output - supported cable diameter 9-16 mm DC input conduit size / # of strings / AWG range 0.75-1" Conduit /1-2 strings 114-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in/mm Weight with Safety Switch 25.3/11.5 Ib / kg Noise <25 dBA Cooling Natural Convection Operating Temperature Range -13 to+140 / -25 to +601 (-40°C option) °F/°C Storage temperature range -40 to +176 / 40 to+80 °F/"C Protection Rating IP65/ Type 3R (Inverter with Safety Switch) 1 Power de -rating from 50'C SolarEdge HD -Wave Inverter Specifications North America MAN -01-00308-1.0 solar- • • SolarEdge Inverter Installation Guide North America, Erratum This update replaces the SE760OA-US single phase 7.6 kW inverter specifications on pages 76-77 of the SolarEdge Inverter Installation Guide, North America Version 3.2 (P/N MAN -01-00002-3.2). Single Phase 7.6kW Inverter Specifications ' A higher current source may be used; the inverter will limit its input current to the values stated. Z Revenue grade inverter P/N: SE7600A-US002NNR2 SE760OA-US Units OUTPUT Nominal AC Power Output 7600 VA Maximum AC Power Output 8350 VA AC Output Voltage Min. -Nom. -Max. 183 - 208 - 229 Vac - AC Output Voltage Min. -Nom. -Max. 211 - 240 - 264 Vac + AC Frequency Min -Nom -Max 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5) Hz Max. output fault current and duration @208V A/ ms Max. output fault current and duration @240V 32/20 A/ ms Max. continuous output current 32 A Max. output overcurrent protection 40 A Power factor 1 GFDI threshold 1 Utility monitoring, islanding protection, country configurable thresholds Yes INPUT Maximum DC power (Module STC) 10250 Transformer -less, Ungrounded Yes Maximum Input Voltage 500 Vdc Nominal DC Input Voltage 350@ 240V Vdc Maximum Input Current' 23 Adc Maximum input short circuit current 45 Adc Maximum input source back -feed current 0 A Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600kO Sensitivity Maximum Inverter Efficiency 98 % CEC Weighted Efficiency 97.5 % Night-time Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional) Revenue Grade Data, ANSI C12.1 Optional2 ' A higher current source may be used; the inverter will limit its input current to the values stated. Z Revenue grade inverter P/N: SE7600A-US002NNR2 solar- • • Recommended OCPD size per grid: Inverter 1208 VAC 1240 VAC SE7600A-US -- 40 A ' Rapid shutdown kit P/N: SE1000-RSD-S1 z SolarEdge's 7.6kW inverter operates at full power and full currents up to a temperature of 120°F/50°C. The inverter may be used above this temperature with reduced ratings. For more information, refer to http://www.solaredge.us/files/pdfs/se-temperature-derating-note.pdf. 3 -40 version P/N: SE7600A-US002NNU4 SE760OA-US Units Rapid Shutdown — NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed' STANDARD COMPLIANCE Safety UL1741, UL1699B, UL1998, CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC part15 class B RoHS Yes INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4" minimum / 16-6 AWG DC input conduit size / # of strings / AWG range 3/4" minimum / 1-2 strings / 16-6 AWG Dimensions (HxWxD) 21 x 12.5 x 7.2 / 540 x 315 x 184 in/mm Dimensions with Safety Switch (HxWxD) 30.5 x 12.5 x 7.2 / 775 x 315 x 184 in/mm Weight 47.7/21.7 Ib/kg Weight with Safety Switch 54.7/24.7 Ib/kg Cooling Natural convection and internal fan (user replaceable) Noise (typical) < 50 dBA Operating Temperature Range -13 to +140 / -25 to +60 2 (-40 to +60 version available 3) °F/`C Protection Rating NEMA 3R Recommended OCPD size per grid: Inverter 1208 VAC 1240 VAC SE7600A-US -- 40 A ' Rapid shutdown kit P/N: SE1000-RSD-S1 z SolarEdge's 7.6kW inverter operates at full power and full currents up to a temperature of 120°F/50°C. The inverter may be used above this temperature with reduced ratings. For more information, refer to http://www.solaredge.us/files/pdfs/se-temperature-derating-note.pdf. 3 -40 version P/N: SE7600A-US002NNU4 solar-.. March 2017 Application Note - SolarEdge String Sizing, North America Introduction There are two primary criteria for string sizing in a SolarEdge system. Maximum (STC) power per string, and minimum and maximum string lengths. This document explains how these values are determined and provides the string sizing rules for the different inverter and optimizer combinations. For additional system design information refer to the inverter and optimizer datasheets. Sizing rules typically depend on the type of inverters and optimizers used: Inverters: single phase or three phase n Optimizers: general or commercial Commercial optimizers can be used only with three phase inverters, while general optimizers can be used with both single and three phase inverters. General optimizers typically have one PV module per optimizer, and commercial optimizers typically have two modules. However these are not fixed requirements and as long as the cumulative power and voltage/current of the modules meets the optimizer specifications as detailed in the datasheet, connecting additional modules per optimizer is permitted (for example connecting 2x120W modules in series to a single P300 general optimizer). Refer to the Connecting Multiple Modules to Power Optimizers application note for details. In the context of this document, string length refers to the number of optimizers and modules in the string. When designing the installation make sure to maintain the maximum physical string length as well: The total cable length of the string (including power optimizers' cables) should not exceed 1000ft./300m from DC+ to DC- of the inverter (2,300ft./700m when using the SE14AKUS and SE33.3KUS inverters). Maximum String Power Maximum string power is simply the "Inverter Nominal DC Input Voltage" multiplied by the "Optimizer Maximum Output Current". These values can be found on the inverter and optimizer datasheets respectively. Table 1 details the values of available products. Table 1: Maximum string power 1 For SE14AKUS only, when used with P600/P700/P730, it is allowed to install up to 650OW per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 1000W. z For SE33.3KUS only, when used with P600/P700/P730, it is allowed to install up to 15000W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2000W. AC Grid Voltage Inverter Nominal DC Optimizer Max Maximum String Inverter Model [V] input Voltage [V] Output Current [A] Power [Wp] Single phase inverters 240 350 15 5,250 SE3000A-US — SE1140OA-US Single phase HD -Wave Inverters SE3000H-US — 240 380 15 5,700 SE6000H-US Single phase HD -Wave Inverter 240 400 15 6000 SE760OH-US 15 6000 (or 6500 in SE9KUS, SE14AKUS 120/208 400 some cases') 18(P800) 7200 15 12750 (or 15000 in SE10KUS, SE20KUS, SE33.3KUS 277/480 850 some casesz) 18(P800) 15300 Table 1: Maximum string power 1 For SE14AKUS only, when used with P600/P700/P730, it is allowed to install up to 650OW per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 1000W. z For SE33.3KUS only, when used with P600/P700/P730, it is allowed to install up to 15000W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2000W. solar=ve Minimum and Maximum String Length The minimum number of optimizers per string depends on the "Maximum Output Voltage" of the optimizer and on the "Nominal DC Input Voltage" of the inverter: the optimizers connected in series in the string must be able to achieve the inverter's nominal voltage. There is a buffer added to ensure the operability of the string also in some shading or fault conditions. The maximum number of optimizers per string was established to ensure proper communications between the optimizers and inverter. • When connecting multiple modules to commercial optimizers, in case of an odd number of modules per string it is allowed to connect one optimizer with one module, as long the minimum number of modules per string is maintained as well. Table 2: Minimum and maximum string length General optimizers Commercial optimizers Single phase inverters Minimum 8 N/A Maximum 25 N/A SE9KUS, SE14.41KUS Minimum 10 8 optimizers, 16 modules Maximum 25 30 optimizers SE10KUS, SE20KUS, SE33.31KUS Minimum 18 13 optimizers, 26 modules Maximum 50 30 optimizers Table 2: Minimum and maximum string length June 20, 2014 Mr. Meir Adest SolarEdge Technologies Ltd 6 Ha'Harash St. HOD HASHARON, ISRAEL 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 756-9891 www.intertek.com Letter Report No. 101703554CRT-001 Project No. G101703554 Ph: +972.9.957.6620 email: meir.a@solaredge.com Subject: ETL Evaluation of SolarEdge Products to NEC Rapid Shutdown Requirements Dear Mr. Meir Adest, This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2014, Section 690.12 requirement for rapid shutdown. This investigation was authorized by signed Quote 500534459 dated 06/10/2014. Rapid shutdown test were perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek personnel on 06/17/2014. The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- amperes within 10 seconds of rapid shutdown initiation. Applicable products: • Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP -XXX -LV, OP -XXX -MV, OP -XXX -IV, OP -XXX -EV; where xxx is any number, 0-9. o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum upto aaa=300, bbb=350 ccc=500, ddd=600, eee=700. o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to mmm=405, nnn=300, 000=350 • 1 -ph Inverters: o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE1140OA-US when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx-x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix Page 1 of 2 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material. product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. Intertek, �✓ Approved Intertek Intertek Intertek Intertek Intertek Intertek Intertek Testing Services NA, Inc. SD 12.1.2 (11/11/10) Informative SolarEdge Technologies Ltd 4 Letter Report 101703554CRT-001 June 20th 2014 • 3 -ph Inverters: o SE9KUS / SE10KUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Completed by: Radhe Patel Reviewed by: Howard Liu Title: Engineering Team Lead Title: Staff Engineer P�1 Signature: Signature Date June 201h, 2014 Date: June 20"', 2014 Page 2 of 2 Intertek Testing Services NA, Inc. SD 12.1.2 (11/11/10) Informative solar - • • = IIID I�III IMAN-01-00II86-1.6) IIIIIIIIIIIII Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents i Rapid shutdown cables Micro -SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. ! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below'. Use a standard straight -bladed screwdriver to disconnect the cables from the terminals. Disconnect here DC connection terminals Disconnect here Switch terminal block Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. Rapid Shutdown Kit Installation - MAN -01-00186-1.6 solar' - • • = Rapid Shutdown Kit - installation and Configuration (Single Phase Inverters) 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 Ib*in): If the cables at the top are red and black from left to right, connect as shown below. Red (+) Black (-) Black (-) Red (+) with rapid shutdown resistor Figure 2: Rapid shutdown cable connected — option 7 If the cables at the top are black and red from left to right, connect as shown below. Black (-) Red (+) Red (+) with rapid Black (-) shutdown resistor Figure 3: Rapid shutdown cable connected — option 2 6 Use a standard straight -bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring -clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*Ib / 1.2 N*m. Rapid Shutdown Kit Installation - MAN -01-00186-1.6 —• Sohl' - • • = Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Inverter Software Compatibility Check and Upgrade Perform this procedure after activating the inverter [Step 1 in Chapter 5: Commissioning the Installation of the SolarEdge Installation Guide], and before pairing (Step 2 in Chapter 5 of the SolarEdge Installation Guide). To use the rapid shutdown feature, the inverter communication board firmware (CPU) must be: • Version 2.0700 or higher, if the CPU version is 2.Oxxx • Version 3.0700 or higher, if the CPU version is 3.Oxxx _* To check the inverter CPU version: 1 Verify that the inverter has been activated using the activation card supplied with the inverter. 2 Press the LCD light button short presses until the screen below is reached. .I D # # # # # # ## # # '..D S P 1/ 2: x. x x x x/ x x x x x 'C P D 0 0 0 2. 0 7 0 0 -'.0 o u n try : R R R R R 3 Check the CPU version number. If lower than 2.0700, upgrade the inverter software as described below; otherwise proceed to "Power Optimizer Pairing". To upgrade the inverter software: Use the supplied SD card adapter or the micro -SD card, which can be removed from the adapter, according to the activation card slot on your inverter communication board, labeled y URD 4' . 7 Verity that the AC breaker connected to the inverter is OFF. 2 Open the inverter cover's six Allen screws and carefully pull the cover horizontally before lowering it, as described in its manual. 3 Insert the card into the card slot on the communication board. If the communication board has an SD card slot, use the supplied SD card adapter. If there is a micro -SD card slot, remove the micro -SD card from the adaptor and insert it. 4 Close the inverter cover and turn the AC on. If upgrade is required (as described above), it starts automatically. 5 Wait for the message "Done" to be displayed on the LCD. 6 Verify the correct version as described above. 7 Remove the card from the inverter and keep it for additional kit installations. Power Optimizer Pairing Pairing at this stage will reprogram the power optimizers to perform rapid shutdown. 1 Verify that the ON/OFF switch at the bottom of the inverter is OFF. 2 Turn ON the AC breaker and the Safety Switch. 3 Perform Pairing as described in Step 2: Pairing, of Chapter 5: Commissioning of the SolarEdge Installation Guide. Enabling Rapid Shutdown There is an option in setup mode to enable the functionality of rapid shutdown. 1 Verify that the ON/OFF switch at the bottom of the inverter is ON. 2 Enter Setup mode by pressing and holding the LCD light button. 3 Select Maintenance 4 Optimizer Conf. 4 Set Rapid Shutdown. • Whenever replacing, removing or adding a component in the string, perform Pairing and rapid shutdown setting. Troubleshooting If the inverter does not enter production mode and the LCD displays Night Mode, the connection order of the rapid shutdown cables may be incorrect. Recheck the cables and make sure that the rapid shutdown cables connected to the bottom of the switch are reversed relative to the cables connected at the top of the switch (see Figure 2 and Figure 3). Rapid Shutdown Kit Installation - MAN -01-00186-1.6 ff Catalog Number: 11TIN Item Description: MIL BANK® UPC Code: ENERGY AT WORK Brand Name: Milbank Type: Ringless Meter Socket Application: Meter Socket Standard: UL Listed Voltage Rating: 600 Volts Alternating Current Amperage Rating: 200 Continuous Ampere Phase: 1 Phase Frequency Rating: 60 Hertz Number Of Cutouts: 0 U4801 -XL -5T9 200A 5T RL HD LVR OU 784572288218 Cable Entry: Overhead and Underground Terminal: Lay in Line Side and Lay in Load Side Mounting: Surface Mount Enclosure: Type 3R, G90 Galvanized Steel with Powder Coat Finish Utility requirements may vary. Always consult the serving utility for their requirements prior to ordering or installing this equipment. This product must always be installed by a licensed electrician. Installation of this equipment may require local electrical inspector approval. milbankworks.com 4 1/1E 13'O.D. FEATURE TABLE ITEM OTY DESCRIPTION A 5 U/L MNTG.EMBOSS B 1 '/. SOLID K.O. C 1 '/,, % CONC. K.O. D 2 1, 1'/., 114, 2,2/ CONC. K.O. E 4 1%,1%. 2,2%, 3CONC. K.O. City of N(heat Ridge Building Divis ------------------------------------- ion ToMILBANICATWORK ENERGY AT WORK I I j All dimensions are +/- 1/16". I Version: Drawing views are not to scale. IUtility requirements for this equipmerrt may I vary. Ahvays mreull the serving utility far I their requirements prior to ordera�J 1 ins -H thin equipmem. This praflUG must t be installed by a Ifcensed electrkian. Installation of this equipmem may require local electrical Inspector approval. RECEIVED .APR 1 0 178 City of rMW heat �d�e - COMUMTY t_im LOPMENT APPROVED Reviewed for Code Compliance / /Mi E , nK a:� of o txrmif ar ogproyol of pbm speClfiCallon wadcomwatiom slam not be o pe.mrt for, or an omproml01 any vlobtbn to aN of the wodsions of the hwlang Code Of of onr city ordinonces. PL mts presumhq to give outhorpy to violare of cancel the provision of the Bu1V codes or other ordinances of the City shag not 6e valid. NV N O PHOTOVOLTAIC SYSTEM SPECIFICATIONS: 4660 Balsam Street SYSTEM SIZE - 6.380kW DC 1 7.600kW AC MODULE TYPE & AMOUNT - (22) JINKO SOLAR JKM290M-60B MODULE DIMENSIONS - (L/W/H) 65.00"/ 39.05"/ 1.57" INVERTER - (1) SOLAREDGE 760OH-US INTERCONNECTION METHOD - SUPPLY TAP ALL WORK SHALL CONFORM TO THE FOLLOWING CODE a. 2017 NATIONAL ELECTRICAL CODE b. 2015 INTERNATIONAL BUILDING CODE C. 2015 INTERNATIONAL PLUMBING CODE d. 2015 INTERNATIONAL RESIDENTIAL CO C. 2015 INTERNATIONAL FIRE CODE d. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0 - SITE PLAN O MOUNT DETAILS E 1.0 - ELECTRICAL DIAGRAM GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: E 3.0 - a. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING ` MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF -MOUNTED THE ROCK -IT SYSTEM BY ECOFASTEN. THE MOUNTING FEET ARE TO BE E 5.1 - SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO THE ROOF SURFACE. ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. yaF b. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 16" LAG 0� CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2y" PENETRATION INTO ROOF FRAMING. C. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM. O d. RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE d. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. INVERTER. RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE e. GROUND SNOW LOAD = 34 psf VOLTAGE. f. WIND SPEED = 115 mph e. SEE *E 1.0 AND *E 2.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND 9, EXPOSURE CATEGORY = B SPECIFICATIONS. PHOTOVOLTAIC SYSTEM SPECIFICATIONS: 4660 Balsam Street SYSTEM SIZE - 6.380kW DC 1 7.600kW AC MODULE TYPE & AMOUNT - (22) JINKO SOLAR JKM290M-60B MODULE DIMENSIONS - (L/W/H) 65.00"/ 39.05"/ 1.57" INVERTER - (1) SOLAREDGE 760OH-US INTERCONNECTION METHOD - SUPPLY TAP ALL WORK SHALL CONFORM TO THE FOLLOWING CODE a. 2017 NATIONAL ELECTRICAL CODE b. 2015 INTERNATIONAL BUILDING CODE C. 2015 INTERNATIONAL PLUMBING CODE d. 2015 INTERNATIONAL RESIDENTIAL CO C. 2015 INTERNATIONAL FIRE CODE d. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: COVER SHEET PV 1.0 - SITE PLAN S 1.0 - MOUNT DETAILS E 1.0 - ELECTRICAL DIAGRAM E 2.0 - ELECTRICAL NOTES E 3.0 - WARNING LABELS E 4.0 - WARNING LABEL LOCATIONS E 5.0 - ELEC PANEL PHOTOS E 5.1 - ELEC MSP/STICKER PHOTOS CAI 01 wheat Midge BUtxd1n5 q.N%5kOn vivi nt. So_lar 1800 ASHTON BLVD. LeK UT, 84043 1.877.404.4129 CO LICENSE: EC.0100200 BREINER RESIDENCE 4660 BALSAM ST WHEAT RIDGE, CO, 80033 UTILITY ACCOUNT #: 5323707808 SERVICE #: S-5886125 COVER DATE: 3/28/2018 DRAWN BY: DIN iSHEET r M O 00 0 U Lu CD 0 ry Q W U) Q U) J Q w m N 0 OLL- � o .0 0 Z � o II 1 d D u I I 1 1 I I O I1 SITE PLAN SCALE: 3/32" = l'-0" N ®U SLOPE - 25 #1)11 MODULES AZIMUTH - 213 MATERIAL - COMP. ® #2)11 MODULES AHINGLE 2 SLOPE -23 AZIMUTH -123 MATERIAL - COMP. SHINGLE City of \{heat Ridge Building Division I SYSTEM LEGEND PV SYSTEM SIZE: NEW 6.380kW DC I 7.600kW AC EXISTING EXTERIOR MAIN SERVICE PANEL TII TO UTILITY METER #68778955. nNEW SREC PRODUCTION METER. LOCATED WIl 10' OF MSP. V NEW PV SYSTEM AC DISCONNECT. LOCATED Q WITHIN 10' OF MSP. 1 NEW PV SYSTEM INVERTER: SOLAREDGE 7600H -US, RSD EQUIPPED. 22 NEW JINKO SOLAR JKM29OM-60B MODULE NEW SOLAR EDGE P320 OPTIMIZERS, MOUNT ON THE BACK OF EACH MODULE. NEW PV CONDUIT RUN.'SEE EE1.0 CONDUIT SCHEDU —_= EXTERIOR RUN =ATTIC I NEW JUNCTION BOX. (MOUNTED TO PV MODULE vivi nt. Solar 1.877.404.4129 BREINER RESIDENCE 4660 BALSAM ST WHEAT RIDGE, CO, 80033 UTILITY ACCOUNT #: 5323707808 SERVICE #: S-5886125 REGIO AL OPERATING CENTER: CO -01 Pv 1.0 DATE: 3/28/2018 DRAWN BY: DIN ROCK -IT ( N ROCK PEDEST 5/1 HEX FLANGE 300 SER (1) 5/1 SS LAG TORQUE=13±2 1 ROCK -IT MOUNT PV 2.O NOT TO SCALE SLIDE METAL ] I I N FLASHING EPDM BONDED WASHER FORMS WATERTIGHT SEAL z. COMP fi milriillill 5/16"x4 1/2" SS LAG SCREW TORQUE=13±2 FT -LBS. SECTION VIEW 3 SECTION VIEW J2.ONOT TO SCALE ROCK -IT COUPLING MID CLAMP ROCK -IT COUPLING SHELF TIE PLATE—/ ' �5/16"xl 1/2" COUPLI HEX FLANGE BOLT SIDE VIEW 300 SERIES SS U.L. LISTING FOR ECOFASTEN 2703 2 ROCK -IT COUPLING ASSEMBLY WEIGHT: 2,3 Ib. PV2.0 NOT TO SCALE NDSCAPE=MAX 72" (6') PORTRAIT=MAX 48" (4') COUPLING, CLAMP -\ — MODULE RAFTER (E)PV SYSTEM MOUNTING DETAIL PV 2.0 NOT TO SCALE 3" MIN AND 6" MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE PV MODULE, TYP. MOUNT 1 TO FRAMING OF EXISTING ROOF TYPE, PARALLEL PV 3.0 WITH PLANE OF ROOF 6" MAXIMUM ��PV ARRAY TYP. ELEVATION PV 2.0 NOT TO SCALE 5 MODULES IN PORTRAIT/LANDSCAPE PV 2.0 NOT TO SCALE MODUI TOP VIEW :FIMtN I G RAFTER L=PORTRAIT CLAMP SPACING MOUNT DETAILS SCALE: NOT TO SCALE vivi nt. Solar 1.877.404.4129 BREINER RESIDENCE 4660 BALSAM ST WHEAT RIDGE, CO, 80033 UTILITY ACCOUNT #: 5323707808 SERVICE #: S-5886125 S `J1 , 0 REGIONAL OPERATING CENTER: CO -01 DATE: 3/28/2018 DRAWN BY: DIN Photovoltaic System DC System Size (Watts) 6380 AC System Size (Watts) 7600 Total Module Count 22 Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) Rapid Shutdown LLn U C: Z w m Ln vQi m C � v ro 0 oo O ui 0 Q w 00 00 0 `•n• o a > Y Tag # Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size 1 PV Wire 10 AWG 2(V+, V-) N/A -Free Air N/A -Free Air 1 Bare Copper Ground(EGC/GEC) 6 AWG 1 BARE N/A -Free Air N/A -Free Air 2 THWN - 2 10 AWG 4(2V+, 2V-) B/R EMT 3/4" 2 THWN-2 - EGC/GEC 8 AWG 1(GRN) EMT 3/4"v 3 THWN - 2 8 AWG 3(11-1 11-2 1N) B/R/W EMT 3/4" 3 THWN-2 - EGC/GEC 8 AWG 1(GRN) EMT 3/4" 4 THWN - 2 6 AWG 3(11-1 11-2 1N) B/R/W EMT 3/4" 4 THWN-2 - GEC 8 AWG 1(GRN) EMT 3/4" placard with black Solar Edge SE760OH-US Milbank R4801 -XL -5T9 Meter Socket; XES 4.11 Compliant;w/Address and "PV PROD" stamped metal tag; <10' from billing meter M INE Square D D222NRB, 240V/60A, Fused, NEMA3, or equivalent 40A ible/Lockable'Knife' AC Disconnect Rapid Shutdown LLn f' Disconnect, Square D C DU222RB,240V/60A, w •� Unfused, NEMA3, or — equivalent; Yellow J — placard with black � v lettering to be installed STRING 2: it PV 1 2 11 J OU stating: "PV AC MODULES DISCONNECT" W/OPTIMIZERS U SHEET M N og STRING 1: 11 PV 1 2 11 \ 0 MODULES NEMA 4 Junction Box 3 W/OPTIMIZERS with Irreversible 3 Phase, with 200A Main Ground Splice (TYP) 22PV MOINVERTER=-- DULES PER 6380 WATTS Disconnect; Yellow OOA • STC Visible/Lockable'Knife' AC placard with black C Disconnect Milbank R4801 -XL -5T9 Meter Socket; XES 4.11 Compliant;w/Address and "PV PROD" stamped metal tag; <10' from billing meter M INE Square D D222NRB, 240V/60A, Fused, NEMA3, or equivalent 40A ible/Lockable'Knife' AC Disconnect V LU LLn f' C LU w •� 00 000 J U 0 � m N J OU 0 s �• v a U SHEET M N og Q 00 0 V Point of Interconnection, Supply Side > w 705.12(A) > Z LU LLn w LU w Z u1 J J U 0 N N J OU 0 Z Z Ln SHEET M Existing 240V/200A Q 00 0 -1 0 Phase, with 200A Main ti 0 Disconnect; Yellow OOA d Ln } placard with black C M w 0 letteringto be installed at ML. Z � O main billing meter Point of Interconnection, Supply Side > w 705.12(A) > Z Minimum GEC size4 AWG copper W LU LLn w LU w Z u1 J J U rj N N J OU 0 Z Z Ln SHEET M Existing 240V/200A NAME: Service Panel, Single Phase, with 200A Main ti Disconnect; Yellow OOA d } placard with black C M letteringto be installed at ML. main billing meter SHEET stating: "PHOTOVOLTAIC SYSTEM CONNECTED" NUMBER: Minimum GEC size4 AWG copper W DC Safety Switch Rated for max operating condition of inverter. Art. 690.35 compliant. Opens all ungrounded conductors Optimizer Solar Edge P320 DC Input Power 320 Watts DC Max. Input Voltage 48 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model Solar Edge SE760OH-US CEC Efficiency 99 % AC Operating Voltage 240 Volts Cont. Max. Output Current 32 Amps DC Max. Input Current 20 Amps Short Circuit Current 40 Amps Max. Output Fault Current 40 A/20 ms Other Notes • Designed according to, and all code citations are relevant to, the NEC 2017. PV Module Rating @ STC Module Make/Model Jinko Solar JKM290M-60B Max. Power -Point Current (Imp) 9.02 Amps Max. Power -Point Voltage (Vmp) 32.2 Volts Open -Circuit Voltage (Voc) 39.5 Volts Short -Circuit Current (Isc) 9.55 Amps Max. Series Fuse (OCPD) 20 Amps Nom. Max. Power at STC (Pmax) 290 Watts Max. System Voltage 1000 VDC (UL) Voc Temperature Coefficient -0.29 %/C AC Output Current According to art. 690.8(B)(1) 31.67 Amps Nominal AC Voltage 240 1 Volts THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Location specific temperature obtained from ASHRAE 2013 data tables. ASHRAE 2013 - Highest Monthly 2% D.B. Design Temp.: 34.7 °C Lowest Min. Mean Extreme D.B.: -29.5 °C Conductor Calculations - Wire gauge calculated from art. code 310.15(B)(16) with ambient temperature calculations from art. 310.15(B)(2)(a). For "On Roof" conductors we use the 90°C column ampacity, 0.5"-3.5" off -the -roof temperature adjustment from 310.15(B)(3)(c), and raceway fill adjustments from 310.15(B)(16). For "Off Roof" conductors we use the 75°C column ampacity, or the 90°C column ampacity with the relevant ambient temperature and raceway fill adjustments, whichever is less. The rating of the conductor after adjustments MUST be greater than, or equal to, the continuous duty uprated output current. Calculation Example - Wire Rating (90°C) x Ambient Temperature Adjustment x Conduit Fill Adjustment >= Continuous Duty Output Current (On Roof, Tag 2): 10 gauge wire rated for 40 A, 40 A x 0.71 x 0.8 (4 Conductors) = 22.72 A>- 18.75 >_18.75 A (Off Roof, Tag 3): 8 gauge wire rated for 50 A, 50 A >= 39.58 A (Off Roof, Tag 4): 6 gauge wire rated for 65 A, 65 A >= 39.58 A OCPD Calculations Breakers sized according to continuous duty output current. PV circuit nominal current based off inverter continuous output current X (1.25[art. 210.19(A)(1)(a)]). Inverter 1: SE760OH-US Max Output = 31.67 A x 1.25 [art. 210.19(A)(1)(a)] = 39.58 A < 40 A (OCPD) system output current w/ continuous duty = 39.58 < 40A (System OCPD) m m 0 N r -I O 00 w m 2 Z LU J N z (SHEET NAME: 0 00 0 m N m c 0 U Q Y 00 00 00 N m v P U 0 0 N O O O U LU w Z Ln LU (y U r7 J 00 0 00 U Lo -W v tkA O M z (SHEET NUMBER: N W .-• - .•� WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Combiner Boxes, J -Boxes, Disconnects, Devices, & Inverters In Un -Grounded Systems Per 690.35(F) (String systems) Conduit, Raceways, and J -Boxes (Labeled Every 10') PHOTOVOLTAIC POWER SOURCE AC Disconnect and Any Load Centers (Combiner Panel) Per 690.17(E) & 705.12 Inverter Output Connection (Solar Breaker) at Main Service Panel Per 705.12 • .Shutdown690.56(C) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Main Service Panel Signage (Installed on the Face of the Service Meter) Per 690.54, 690.56(B), & 705.10 Note: Roofline placard not needed unless PV disconnect is not at the same location as the main service DC Disconnect Per 690.17 ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. ALL PLACARDS SHALL BE WEATHER -RESISTANT, PERMANENTLY ETCHED PLACARDS. HANDWRITTEN SIGNS WILL NOTE BE ACCEPTABLE. Piro por el5 re,�-��c� P'r 4/,Ff, //0. .4-1 (A) ,4 /V�6 j_- 21 �3 �7, V - ?-0// 53 W CL S S' to 0) n < ;D c y Q 0 Rapid Shutdown Per 690.56(C)(1)(a) Installed On AC Disconnect SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY 00 m O m 00 U 0 0 aO cmv U m v CCL' Lr, m o Z3 w Z O ° E5 � < Q d af Q m = rn N r-1 O n O 00 Q O O '^' L O LU o z C0 0 �w z w V) w LL, z v, J J W N J J U -I J ID `" V' O 00 z z U 00 SHEET NAME: SHEET NUMBER: M LJ CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED 1 Property of Vivint Solar 4 MICRO -INVERTER SYSTEMS STRING -INVERTER SYSTEMS WARNING: DUAL POWER SOURCE MAIN BREAKER DE -RATED TO *** DUE TO SOLAR RATED AC OUTPUT CURRENT: *** A 2 CIRCUITS ***AMPS WARNING: PHOTOVOLTAIC POWER SOURCE MAX OF PV SOURCE ALLOWED PHOTOVOLTAIC AC DISCONNECT DO NOT INCREASE MAIN BREAKER RATING NOM. OPERATING AC VOLTAGE: *** V Property of Vivint Solar Property of Vivint Solar SHUTDOWN 3 WARNING Property of Vivint Solar ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Property of Vivint Solar 7 MICRO -INVERTER SYSTEMS STRING -INVERTER SYSTEMS WARNING: DUAL POWER SOURCE SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: *** A NOM. OPERATING AC VOLTAGE: *** V Property of Vivint Solar WARNING: PHOTOVOLTAIC POWER SOURCE Property of Vivint Solar PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: *** A NOM. OPERATING AC VOLTAGE: *** V Property of Vivint Solar PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Property of Vivint Solar PHOTOVOLTAIC DC DISCONNECT Property of Vivint Solar SOLAR INVERTERS (MAY BE ON ROOFTOP INTEGRATED WITH ARRAY) 9 WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Property of Vivint Solar 10 WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Property of Vivint Solar WARNING 1 ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED Property of Vivint Solar 13 SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE AND DISCONNECT LOCATIONS. PLACARD SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL PANEL (only when necessary) Property of Vivint Solar PHOTOVOLTAIC POWER SOURCE DC DISCONNECT 11 RATED MAXIMUM POWER POINT CURRENT (IMP) *** A 14 PV rapid shutdown disconnect RATED MAXIMUM POWER POINT VOLTAGE (VMP) ***V placard indicated on E.3 MAXIMUM SYSTEM VOLTAGE (VOC) *** V SHORT CIRCUIT CURRENT (ISC) ***A Property of Vivint Solar *** - value calculated for each account, for specific value see the previous warning label page COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) (WHERE REQUIRED) TYPICAL SOLAR GENERATION INSTALLATION (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) VISIBLE/LOCKABLE A/C DISCONNECT IF APPLICABLE City of Wheat Ridge Building Division MAIN SERVICE DISCONNECT PANEL ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT (DC) CONDUIT, ENCLOSURES, SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT RACE -WAYS, CABLE ASSEMBLIES, JUNCTION BOXES COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRE SERVICE TO TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. AVOID CUTTING THEM. MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT (3048 MM), WITHIN 1 FT (305MM) OF ALL PLACARDS SHALL BE WEATHER -RESISTANT, PERMANENTLY ETCHED PLACARDS. TURNS OR BENDS AND WITHIN 1 FT (305 MM), ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR HANDWRITTEN SIGNS WILL NOTE BE ACCEPTABLE. BARRIERS 00 m O m 00 0 0 C `^ °o m - 2 O N U m W N Ln 'Ifw = LU m o � Q o z V v a a = m = Y 00 00 N m v v U a) N v O a 0o O O N N cs� O � w O z 0o o U z w z V) LU w Z Ul J J w N J J U F J Lo V1 !n O W Z Z U Ln SHEET NAME: ao c 3 -0 bA a SHEET NUMBER: NOTES 0IN 0 \,peatR`dge vivi nt. Solar 1.877.404.4129 BREINER RESIDENCE 4660 BALSAM ST WHEAT RIDGE, CO. 80033 UTILITY ACCOUNT #: 5323707808 SERVICE #: S-5886125 REGIONOPERATING CENTER: CO -01 E 5.1 DATE: 3/28/2018 DRAWN BY: DIN - 4?- 94��-- 20 7 v (�,�'�INSP ECTION RECORD oc�u anc / Ie INSPECTION ONLINE FORM: http://www.ci-wheatridge.co.us/inspection lX Cancellations must be subm tted viaCtheONonline REQform Ubefore 8EST 1 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site. "Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business da Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Pier Date Inspector Initials Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Underground/Slab Inspections Date1�1n�itials Electrical Sewer Service Plumbing Do Not Cover Uncle Rough Inspections Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric' Roug IPh mu bing/G Line ni e Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Comments Of The Above Ins and or Below/In-Slab Work Prior To Date Inspector Initials Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building o/12- Landscaping /2 Date Inspector Initials Comments roval Of The Above I Comments Comments ctions Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits —Please be sure th by the Building Division. at rough inspections are completed from the Fire District and electrical low voltage Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PERMIT - 201706652 ISSUED: 08/28/2017 ;RMIT NO: 201706652 EXPIRES: 08/28/2018 5 )B ADDRESS: 4660 Balsam ST -roof to install GAF Timberline HD asphalt shingles with JB DESCRIPTION: Residential Re sq. ** CONTACTS *** WNER (303)472-5561 BREINER JAMES K SR 017911 Alpine Roofing Co., Inc. UB (303)295-7769 Robin J. Tichy ** PARCEL INFO *** USE: UA / Unassigned ONE CODE: UA / Unassigned 0 / AI HEIGHTS, ME BLOCK/LOT#: ;UBDIVISION CODE: 2406 / BEL ESTIMATED PROJECT VALUATION: 16,627.00 ** FEE SUMMARY *** FEES 0.00 Dotal Valuation 349.17 Jse Tax 315.25 Permit Fee 664.42 ** TOTAL ** *** COMMENTS *** *** CONDITIONS *** roved midroof Effective December 1, 2014, asphalt shingle installations require is an app prior to final inspection, conducted when 25-75 percent onewhorroverlay)risgrequired aonedthe entire roof approval. Installation of roof sheathing ing one half inch exists. Sheathing and with ANY gap e when spaced or board sheathing ercent of the sheathing must be mid -roofs may be called in at the same time, one hundred ete. Asphalt shingles are required complete and 25-75 percent of the mid -roof may le. Ice and water shield to be fastened to the roof deck with a minimum oladderlls per extendinglg 3feet above the roof eave is required. Eave and rake metal is required. and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, or whichever is more stringent. In order to pass a pprovalnal inspection fromtheomanufacturerctechnicalsimilar a type roof coverings, a letter of inspection and app (project ect address) has been representative stating that "the application of the roof at applied in accordance with thenonasitelat thettimelof finalrooinspectional brand name) roof covering" is required toeb rty ll be Midroof & Final Roof inspections for ROOFS AOVER ND E/ ORIGINAL 12 'PERMIT aCARD 1needs ttonbeldropped required, the 3rd party inspectionreport off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. N* i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: r— i ra� ' Job Address: AUUD �Lg? ' ':5'r Permit Number: _ono ((J u G 2_ ❑ No one available for inspection: Time 11DU @PM Re -Inspection required: Yes No When corrections have been made, call fo e -inspection at 303-234-5933 Date: t ID Inspector: n �` L&4,_ DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201706652 PERMIT NO: 201706652 ISSUED: 08/28/2017 JOB ADDRESS: 4660 Balsam ST EXPIRES: 08/28/2018 JOB DESCRIPTION: Residential Re -roof to install GAF Timberline HD asphalt shingles with 50 sq. *** CONTACTS *** OWNER (303)472-5561 BREINER JAMES K SR SUB (303)295-7769 Robin J. Tichy 017911 Alpine Roofing Co., Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 16,627.00 FEES Total Valuation 0.00 Use Tax 349.17 Permit Fee 315.25 ** TOTAL ** 664.42 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. e City of Wheat Ridge Residential Roofing PERMIT - 201706652 PERMIT N0: 201706652 ISSUED: 08/28/2017 JOB ADDRESS: 4660 Balsam ST EXPIRES: 08/28/2018 JOB DESCRIPTION: Residential Re—roof to install GAF Timberline HD asphalt shingles with 50 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable buildin codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal er f the prope and am authorized to obtain this permit and perform the work described and approved in conjunction with this perm h attest tha am legally authorized to include all entities named within this d current as parties to the work to be pe Orme and all work t be performed is disclosed in this document and/or its' accoing approved plans and specifications. Signature of"�OWNER of/ CONTRACTOR (Circle one) Date ` l 1. This permit was issued ased on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the original _permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall of be o trued to be a permit for, or an approval of, any violation of any provision of any applicable code or r inancee op11i o h jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz aG 17 0665-.�)— From: no-reply@ci.wheatridge.co.us Sent: Thursday, August 24, 2017 4:03 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Danny Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. a , For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION X11\ i Property Address 4660 Balsam St Property Owner Name Jim Breiner Property Owner Phone 303-472-5561 Number (enter WITH dashes, eg 303-123-4567) 33 -t � co 4-. 4 -2, Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Field not completed. Yes 22970 SIGNED CONTRACT.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Alpine Roofing Co., Inc. 017911 303-295-7769 4780 York Street, Denver CO 80216 Contractor Email Address dcarey@alpineroofingco.com Retype Contractor Email dcarey@alpineroofingco.com Address DESCRIPTION OF WORK TOTAL SQUARES of 50 the entire scope of work: Project Value (contract 16627 value or cost of ALL materials and labor) Are you re -decking the No ✓ roof? 34 Does the scope of the No project include a flat roof (less than 2:12 pitch)? Does the scope of the project include a pitched roof (2:12 or greater pitch)? How many squares are part of the pitched roof? Describe the roofing materials for the pitched roof. Type of material for the pitched roof: Provide any additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Yes ✓ 50 GAF Timberline HD asphalt shingles Asphalt For house, garage, & shed. Pitch is 5/12 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. Yes Yes Yes 35 I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Denyell Carey Email not displaying correctly? View it in your browser. 36 AUUNNU UCCUINC CCI, INC. R.TICHY FLAT • BUILT-UP • COMPOSITION • STEEL • COPPER • SHEET METAL SjreciafrziV inAdr7 pes Commercial, ltdstriafand~kfsideutiaf&ofn j To Jim Breiner DATE June 6, 2057 4780 YORK STREET 4660 Batsam St DENVER, COLORADO 602164235 PHONE (303) 295-7769 Wheat Ridge, Co 80033 ATTENTION: Jim Breiner FAX (303) 296-6803 JOB LOCATION 4660 Balsam St Wheat Ridge, Co 80033 — House, Garage & Shed (Excludes rear patio) Alpine Roofing Co.., Inc., proposes to furnish all labor, material and equipment necessary to complete the work outlined as follows: Deck Prc awn • Protect ground surface from falling debris below demolition • Proper removal and disposal of I layer of existing roofing materials. • Remaining fasteners to be driven flush with roofdcc.k. • Inspect decking and re -attach as needed, • Replace damaged/deteriorated decking at the rate of $72.00 per 4'x8' sheet Undrrinyinentii • Install GAF WeatherWatch self -adhering mtderlayment approximately 3' up from eaves on the house and garage only, • Install 2 layers of Tarco Easy Lay synthetic underlayment over remaining low sloped roof deck not covered by WcatheAk'ateh and one layer over remaining roof decks not covered by WeatherWatch Fhtshino, • Replace all pipe flashing with new. • Replace all attic vents with new, • Install 26 gauge pre -finished steel flashing at eave, rake edges, sidcwalls, backwalls, and headwalls as required_ • Paint all plumbing, attic vents and heating vent flashings, R6t_ raitl#.L • Install new 5" pre -finished seamless gutters with 3"x 4" downspouts to match. • Install 36" wide valley litter centered in valleys, • Install GAF Timberline H.B. asphalt shingles per manufacturer's specifications including sta€rter and hip & ridge shingles.. • Remove all debris from the site. • Nail magnet to be run at perimeter of grounds or, a daily basis. • 5 Year workmanship and manufacturer's warranty will be issued upon completion and payment in full (we accept cash, check, Visa, Amex & MasterCard). • All work to be completed in accordance with local building codes. Cost: Twenty Four Thousand Nine Hundred Thirty Dollars ($24,930.00) YES—No- Discounted price if paying by check or cash Cost: Twenty Four Thousand Two Hundred Dollars ($24,200.00) VES ,N a Our price includes all necessary licenses, permits, taxes and insurance to be paid by Alpine Roofing Co., Inc. Thank y ou for the opportunity to submit this proposal. If we can be of further assistance, please feel free to contact our office at your convenience. This proposal becomes a contract when one signed copy is returned to our office Quafity service shoe 1960 0 TERMS AND CONDITIONS: The above proposal, if accepted as a contract or accepted on any other contract form, incorporates all provisions stated herein. Insurance: The Company agrees to carry sufficient workmefi s Compensation and Public Liability Insurance to protect the owner against any claims arising due to the Company's operations. The Accepting Party agrees to provide sufficient insurance to protect the Company against loss of labor, materials or equipment installed in or on the premises. Surety & Liability Coverage provided by Keller -Lowry Insurance Inc (303) 756-9909. Guarantee: Printed on the reverse side of this proposal and incorporated herein, by reference, is the MRCA Form 2007A Guarantee, which will be supplied upon completion and acceptance of our work. No other expressed or implied warrant is made. The liability of the company is subjected to and limited by the tents and conditions contained in this guarantee.. Reasonable Control: The Company shall not be responsible for damage or delay due to considerations beyond its reasonable control Including the availability of all materials. Substitutions maybe required. Additions or deviations shall be considered as a change to the contact. Terms: Net on completion. Interest at 11/2% per month (18% per annum) will be charged for all past due amounts. This proposal is subject to the approved credit of the purchaser. It is valid fore period of 30 days, and Is subject to change or withdrawal after that date. These terms are binding unless otherwise state in proposal. Facilities: The Accepting Parry agrees to provide the company with sufficient storage room for all materials on the jobsite,. Attorneys Fees and Costs: In addition to Injunctive relief and/or monetary damages, the corporation will be entitled to recover it's reasonable attorneys fees and costs, including any expert witness costs, Incurred in enforcing this agreement. Exclusions: All other items of work not specifically mentioned are excluded, Project Start/Completion Date: Mork will[ be performed within approximately 30 days after receipt of signed contract weather permitting and approval of customer. Timeframe is subject to change and notification will be provided to the customer if more time Is needed. Additional Terms: Property owner may rescind the contract for roofing services within 72 hours of signing contract and obtain full refund of any deposit within 10 days. If the property owner plans to pay for roofing services through an insurance claim, Aipine Roofing Co., Inc., cannot pay, waive, or rebate the homeowners insurance deductible in part or in whole. Alpine Roofing Co., Inc. shall hold In trust any payment received from you until Alpine Roofing Co., Inc. has delivered roofing materials at the site or has performed a majority of the roofing work on your property. Property owner may rescind this contract within 72 hours atter receiving written notice from the property and casualty insurer that the clalm has been denied in whole or in part.- However, Alpine Roofing Co Inc. is entitled to retain payments or do snslis to compensate Alpine Roofing Co„ Inc. for roofing work actually performed in a workmanlike manner consistonfw[grtstan cirri ng in practices Respectfully Submitted by, Richard Schafer (Sala�€blratirtg); -.�" f,--��- ACCEPTED U DATE: � i i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: .k ❑ No one available for inspection: Time Re -Inspection required: Yes- Nom. When correcti ns have been made, call for re -inspection at 303-234-5933 � 1�. Date: �C� % Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE ~-j Building Inspection Division ~ (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: %i`~~L✓ Job Address: Ve~~6 13114<117✓J sr Permit Number: ©`IYSS 3 ❑ No one available for inspection: Time Afv1IPM i Re-Inspection required: Yes (No, *When corrections have been made, call for re-Inspection at 303-234-5933 Date: Inspector: f DO NOT REMOVE THIS NOTICE 2/30/2009 WED 17:51 FAX 303 237 8929 303 Best way UQ. OT4 - 4 INESPECT1ONl RECORD OGCNpancv/Tvi ' LINE; (303) 234 -5933 — Inspections will not be made unlees this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. 4 6 3 _ INSPEC O MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR COMMENTS: INITIALS Stemwall.I (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof French Drain Sewer Se rvice Lines Water Service Lines CONCRETE SLAB FLOOR Elect (Underground) Plumbing (Undergrounds) ROUGHS Lath / Wall tie Mid - Electrical Service Rough Electric Gas Framing Insulation Drywall Screw - E 4: , � y 1 � �ZT 8r' WNENI RIDGE -' u,+ 3OVE INSPECTIONS TO BE SIGNED PRIOR T 'v y 4 11C T _ ; kkCEIpTY'HDYGD8603686 A�fOUt#i BPSP RQrDD;18 sqs :, 229 3& �`lkz'reiB:Fe� . �' x —� 144870 ih Use a , — — _ — 84:88 FINALS Mechanical Roof . FiraDepaRment P & Drainage INSPECTIONS FOR PLANNING & ZONING.. FIRE AND PUBLICS WORKS arking 8. Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING BUILDING AND PUBLIC WORKS BEFORE q CERTIFICATE OF OCCUPANCY 1S !$SUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCIIPGNr_Y 1Unr IPG0fifi 1 4F 11 r+r Ir e. . ,,.. ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPETIO OTICE Inspection Type: Job Address: ,Q ca_ Permit Number: ❑ No one available for inspectio Time t0 Mf M Re-Inspection required: Yes rv.° "When corrections have been made, call for re-inspection at 303-2345933 Date: jG) Inspector: DO NOT REMOVE THIS NOTICE " ' City of iWheat Ridge Residential Roofing PERMIT - 094583 PERMIT NO: 094583:. ISSUED: 12/30/2009 JOB ADDRESS:: 4660 BALSAM ST. 'EXPIRES: 0.6/28/2010 DESCRIPTION: Reroof`house and garage 50 sqs CONTACTS owner 303/472-5561 JimP Breiner. sub 303/295-7769 Robert Tichy 01-7911 Alpine Roofing Co., Inc. PARCEL INFO )NE S.CODE: UA : J13DIVISION:' 0311 ?USE: UA .'.BLOCK/LOT#: 0/ t FEE SUMMARY ESTIMATED PROJECT VALUATION: 10,650.00 FEES Permit Fee 253.90 Dotal Valuation .00 r-w 6 Jse Tax 191.70 *-TOTAL 445.60 Dnditions:' Dth front and back of permit need to be posted on job site. If one or the other not present, INSPECTION WILL NOT BE PERFORMED. nail installation & mid roof inspertion rerniired Board sheathina snared more ter shield.: required from eave edge to 2' inside exterior walls. ***Contractor Property owner shall provide ladder(s) secured in place for inpsections. It the responsibility of the person/firm requesting the inspection to insure Dfs are clear for inspection. Scheduled inspections that cannot be performed a to inclement weather must be cancelled prior to 8:30 a.m. on the day of 3pection or a re-inspection fee of $61.00 will be assessed. Subject to field epection. weer date rmit. con1r.avcocnoucy. cnc nui raing inspector twenty-your ~z4) nours in savants cor all inspections ana snail receive.:: written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a .permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law,' rule or regulation.. All plan revie rs ject to field inspections. signature of# ie ildrng, Official "date INSPECTION RECORD OccugancylTVi INSPECTION LINE: (303) 234-5933 L Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB OFNDAT TION INSPECTIONS DATE INNITIALSSPECTOR COMMENTS: I Caissons / (CEG) Concrete Ground g or Monolithic roof / French Drain vice Lines vice Lines CONCRETE SLAB FLOOR Electrical (Underground) Plumbin g (Underground) LRoUGHS ng all tie f Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical Framing Insulation Drywall Screw ABOVE TO BE SIGNED FINALS Electrical Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. nr'r'I 10 A AI('v IVn-r DCOnniTT 11..T.. r+. Dec 30 2009 1:30PM Alpine Roofing Co., Inc. 3032966803 p.2 Property Address: ~„F City of S4 Wheat idge Date: Permft#: Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax; 303-237-8929 Inspection Line: 303-234-5933 Facsimile Building Permit Application 4660 Balsam St property owner (please print): Jim Breiner Mailing Address: (if different than property address) Address: City, State, Zip: Contractor: Alpine Roofing Co., Inc. Contractor License #:17911 Phone: 303-295-7769 Sub Contractors: Company Name: License Exoiration Date: Trade/Profession: Approval: Use of space (description): House & Garage Description of work: 10,850.00 Remove existing roofing material and install new underlayment Plan Review (due at fime of suomittao- S and 30-year shingles on both the house and garage. Sq. Ft/L.Ftadded: Squares 50 BTU's Gallons Amps OWNER(CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for Compliance with the VWeat Ridge Building Code (I.E.C) and all other applicable Wheat Ridge Ordinances, for work under 1113 perrnL Plans subject to field Inspection. CIRLCEONE: (OWNER) ONTRACTO or PERSONAL REPRESENTATIVE of (OWNER) (CQNTR§MM PRINT NAME: Robert D. Tichy, President SIGNATtlIIE -c._-~ - Date: 12/30/09 DEPARTMENT USE ONLY ZONING COMMENTS: Zoning: Reviewer. PUBLIC WORKS COMMENTS Reviewer. allILDING DEPARTMENTCOMMENTa OCCUPANCY: Reviewer. FIRE DEPARTMENT:: O approved cal comments 0 disapproved 0 no review required Bldg Valuation: $ Phone: 303-472-5561 Credit Card Payment: Use credit card listed on file. ate:. 12130 09 Print name: Robin J. Tichy, Corp. Secretary Signature: ~ COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: 17546 13UILDING INSPECTION LINE - (303 - 234 -5933) Date: 8/12/2004 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303- 235 -2855) Property Owner: JAMES K & ROSEMARY BREINEZ Property Address: 4660 BALSAM ST Phone : 940 -5955 Contractor License No.: 19557 Company: Security Plumbing & Heating Phone : 422 -6675 OW NER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OW NER)(CONTRACTOR) Construction Value : $3,000.00 Permit Fee: $108.30 Plan Review Fee: $0.00 Use Tax: $36.00 Total: $144.30 Use: Description : REPLACE WATER LINE (WATER SERVICE TO HOUSE) BUILDING DEPARTMENT USE ONLY Zong re SIC Approval Zoning: Approval : Sq. Ft. : Approval : Occupancy: Walls: Roof: Stories : Residential Units: Electrical License No : Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date : Expiration Date : Expiration Date Approval : Approval : Approval : (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The is a pe e I of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the i th firlinq codes or a Mafter ordinance, law, rule or regulation. Chief Building Inspector Please sign Terms and Conditions on reverse side of page. � r ♦ 9 u COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303.234.5833 CITY OF WHEAT RIDGE 7500 WEST 28TH AVENUE WHEAT RIDGE, CO 80033 - (303 -23$-2855) Property Owner. j A It 8. S asyrgla2Y 1S2 Property Address: `l 4 G v S a t 5 4" Contractor license No.: �CAeS 5 r� 0WN6RICGtTRACT0R 94NATURE OF U 1 hereby certify that the Setback distances proposed by this permit appficalm are accurate, and do not violate applicable ordinances. hues orregutations of theCity Of Wheat Ridge admvenarss. easements :#•resaitdianso allmeasuremenis shown. and aaagaaerns made am aeoaraW, that I have read and agree to abide byall conditions printed on this application and that 1 assume fait responsibility for compaance with the Wheat Ridge Building Code ((J$_C) and all other applicable Wheat Ridge ordinances, for work under thks permit towmaq(c NiRH.'roat SKp7E0 DATE Bantling Permit Ntenber. Data: 2 Phone: 3v3 fb 5y 5� Phone: instruction Value:$ 31 om C Permit Fee:$ Plan Review Fee :$ t IRP T Total :$ towtie0cdNmACron)7+1t1NrED pp Description: fz ,r_k'M/yC d- LJPia -f- Y r�� \ ^i °�L2 S�4 ✓rCL � 1�oJS�� Sq. Ft. added 0 A2 k Expiratjon Date: Expiration Date: Expiration Date: Approval: Approval' ® ®e Appn>val: _ (t) This permitwaslssasd Inacaadwsm wipr are 9mvillic"00foM ln)Owappaeaacnand is subject to the laws of theSla4ot Coloradoand tolhe Zoning Regulations and Building Codes of Wheat Ridge. Colorado Man cow applicable ordinances of the city. (2) This permit shelf expire if (A) are work auaiorind " *I cmunanced within sbdy (60) days both issue, date Of (8) the building auarorzed is suispended or abandoned for a period of 120 days. (3) If ads lwraftex eres.anew permit maybe acquired (Ora fee ofonehaBths amount kwrmatlyragwrsd .pmvidednochanges have Crean or wID be made bn owodgkW om wo speaagons and any su W emkn or abordw~t hu aat..exoesded as tt) yaer. IfdtangeattavebeenarTauspeitswnorabandmurpent (t) year. fidlfresahaitbopaldforanewpemdE. (4) No work of any manner Stu be do" that wkf change Me naeuat flow of water causing a drainage problem.. (5) Conbapor shelf n" the Buadbp Inspector twemy i (24) hours in advance for as nspeclim and shall receive winters approval on Inspection cart before proceeding with successive phases of the job_ (6) The fswanae of a pem % or the appmvat of drawings and spsOYfWlions shall nct be ennstrued: to be a permit for. nor an approval of.. any notation of the provisions W th building codes or any ot ordinance. low. ndaor regulation. Chief Building Offic(al EhrcVical License No: Plumbing License No: Mechanical License No: Company: Company: Compawr