Loading...
HomeMy WebLinkAbout30 Hillside Drivea PERMIT. ADDRESS., JOB CODE: INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation 306 Mid -Roof Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 306 Mid -Roof 206 Water Underground 308 Rough Electrical Residential Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous 2 Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 2 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. i CITY OF WHEAT RIDGE - Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: _7 y ( I Job Address: 33 f�� �`% ide �s Permit Number: 0 yy XI 1 ❑ No one available for inspection: Time %'0 AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: 71/ 117 Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �z Job Address: Permit Number: ❑ No one available for inspection: Time 1 `����' AM/P'M Re -Inspection required: Yes o When corrections have been made, call for re -inspection at 303 -234 - Date:— 1 / " .! Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201707849 PERMIT NO: 201707849 ISSUED: 09/29/2017 JOB ADDRESS: 30 Hillside DR EXPIRES: 09/29/2018 JOB DESCRIPTION: Residential Re -roof to install Polyurethane Foam with Acrylic roof coating(United Coatings Diathon) - 60 sq (12 sq pitched / 42 sq flat) Pitch = 2/12 *** CONTACTS *** OWNER (720)288-5735 HOFFMAN CLIFFORD M, SUB (970)535-9666 Roger Kemper 090379 Counce Kemper Specialty Contra *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2404 / APPLEWOOD KNOLLS, PARAMOUNT HE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 45,231.00 FEES Total Valuation 0.00 Use Tax 949.85 Permit Fee 683.55 ** TOTAL ** 1,633.40 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. ► City of Wheat Ridge "r Residential Roofing PERMIT - 201707849 PERMIT NO: 201707849 ISSUED JOB ADDRESS: 30 Hillside DR EXPIRES: JOB DESCRIPTION: Residential Re -roof to install Polyurethane Foam coating(United Coatings Diathon) - 60 sq (12 sq Pitch = 2/12 09/29/2017 09/29/2018 with Acrylic roof pitched / 42 sq flat) I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specification applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authc by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction this permit. I further att hat I am le ally authorized to include all entities named within this document as parties to the work to be performed and that to be prn}edjs disclosed in this document and/or its' accompanying approved plans and specifications. Signature of &W1 R r t(TKTIzACTOR (Cide one) Date I. This permit was isstdd based on the information provided in the permit application and accompanying pFlans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granterg.Qja permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code ora ordi a�ncreorrrreguk4on of t 's ju isdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett - o/ V ZOO From: no-reply@ci.wheatridge.co.us Sent: Tuesday, September 26, 2017 9:03 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) 30 Hillside Drive Clifford M. Hoffman 720-288-5735 213 Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Doesn't use email Yes CK2017-Hoffman Roof Contract for Wheat Ridge Roof Permit.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Counce Kemper Specialty Contractors, Inc. 090379 303-877-8002 103 Grand View Circle / Mead, CO 80542 Contractor Email Address rakemper.ck@gmail.com Retype Contractor Email Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or rakemper.ck@gmail.com 5 q /uares 7$45,231.00 No l Flat roof (less than 2:12 pitch), Pitched roof (2:12 pitch or greater) 214 4 both? (check all that apply) What is the pitch of the Completely flat FLAT roof? How many squares are 42 Squares part of the FLAT roof? Describe the roofing Spray Polyurethane Foam (1-1/2") Minimum Thickness, Slope material for the FLAT to Drains. Acylic Roof Coating (United Coatings Diathon) t' roof: Type of material for the Other (specify below) FLAT roof. If "Other" is selected Described Above. Matches that previously installed and above, describe here: approved by Wheat Ridge in 2010. What is the specific pitch 2/12 of the PITCHED roof? How many squares are 12 Squares part of the PITCHED ` roof? Describe the roofing Same as that for the flat roof section, except foam thickness materials for the will not exceed 1 1/2". PITCHED roof: Type of material for the Other PITCHED roof: If "Other" is selected This is the center section of the residence sloped drainage to above, describe here: South edge of back side of residence. Provide any additional No additional information is needed. detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit 215 issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Roger A. Kemper Email not displaying correctly? View it in your browser. 216 COUNCE KEMPER SPECIALTY CONTRACTORS, INC. P.O. BOX 54 (970) 535-9666 MEAD, COLORADO 80542 FAX (970) 535-6191 BID PROPOSAL PRESENTED TO: Cliff Hoffman 30 Hillside Drive Lakewood, CO 80215 Phone: 720-288-5735 RE: Hail Damage Foam Roof Rehab From May 8th Hail Storm. NATURE OF WORK We examined your roof in May and have worked out the details for redoing the roof with your carrier, The Hartford. That effort was finalized around mid June, with some amended follow-up regarding fireplace flashing and perimeter trim painting. With the type of damage sustained, this is going to be a complete removal and replacement type effort. A roll -off dumpster will be brought on site and positioned next the East side of the residence to provide for ease of removal of all roof debris. We will remove the polyurethane foam roofing in sections, prime the deck and follow with new foam placement to match what was the previous foam thickness on the roof. By doing the work phases in sections, minimal exposure for unexpected weather events shall be eliminated, since roof work shall be dried in on a daily basis. Foam thickness shall again be at a nominal one and one-half inches (1-1/2") for both the flat and low sloped middle section on the roof. On the flat elevations we will add additional foam between the internal roof drains to enhance water drainage. This likely will constitute an additional one-half inch (1/2") in average foam thickness, so that polyurethane foam insulation thickness will at some locations be as much as two and half -inches (2-1/2") at the high points between the roof drains. Additionally, we will create a slightly rounded foam edge detail along the perimeter of the roof, so that water does not run over the edges, due to the added foam thickness in some areas. Some flashing will be replaced as necessary, as will one skylight dome. Two coats of acrylic roof coating are planned for the completed foam installation. Manufacturer shall be United Coatings with product tradenamed Diathon (25 to 30 dry mils), with roof color to be white. Project includes the repainting of trim around the perimeter of the residence. We will need access to Bid Proposal - Cliff Hoffinan (Foam Roof Hail Damage Rehab) Counce Kemper Specialty Contractors, Inc. Page - 2 NATURE OF WORK (CONTINUED) residual paint that you have on hand, so that color matching can be properly handled at the time additional paint is purchased. Job includes all applicable permit fees for the City of Wheat Ridge. We anticipate scheduling in the month of August, due to some equipment upgrades that were undertaken which delayed some of the foam work on our schedule, plus a little more time lag for processing permits due to the volume of work resulting from the May hail storm. ITEMIZATION OF CHARGES Total cost for job to be a lump sum total of $45,231.00 (FORTY -FIVE -THOUSAND TWO - HUNDRED -THIRTY-ONE AND NO ONE -HUNDREDTHS DOLLARS). Above quotation shall be valid for only thirty (30) days from date of issuance. WARRANTY A new ten (10) year leak -free warranty shall apply to the completed foam roof system rehab installation. Excluded from warranty shall be all unusual acts of nature, structural -related problems, animal, bird, or man-made damages. PAYMENT TERMS Fifty percent (50%) of contract total or $22,615.50 (TWENTY -TWO -THOUSAND SIX - HUNDRED -FIFTEEN AND 50/100 DOLLARS), shall be due upon start of work. The remaining fifty percent (50%) balance of $22,615.50 (TWENTY -TWO -THOUSAND SIX -HUNDRED - FIFTEEN AND 50/100 DOLLARS), shall be due within ten (10) days of completion of work, based upon client's receipt of final billing. Please note that The Hartford people have provided instructions for our submittal of the final invoicing for your roof job, so that the recoverable portion of your depreciation can be claimed while our work is in process. Denis Ogle, your claim representative, will give it personalized processing, so that those funds can be received by the time we are at full completion on the roof. DEFAULT AND DISPUTE RESOLUTION All sums due Counce Kemper Specialty Contractors, Inc., under this Agreement not received on or before their due date, shall draw interest at the rate of one and one-half percent (1-1 /2%) per month, Bid Proposal - Cliff Hoffman (Foam Roof Hail Damage Rehab) Counce Kemper Specialty Contractors, Inc. Page - 3 DEFAULT AND DISPUTE RESOLUTION (CONTINUED) or eighteen percent (18%) per annum. In addition to all other relief to which Counce Kemper Specialty Contractors, Inc. may be entitled, upon breach by client, Counce Kemper shall be entitled to full reimbursement for all costs and expenses of collection, including time spent by Counce Kemper personnel and for all attorneys' fees incurred calculated at $300.00 (THREE -HUNDRED AND NO ONE -HUNDREDTHS DOLLARS) per hour. At the option of Counce Kemper, any disputes between the parties shall be resolved either by binding arbitration or by litigation. If litigation, the jurisdiction and venue of the Jefferson County/District Court is hereby acknowledged and agreed. If arbitration, the parties stipulate and agree that their dispute will be resolved by binding arbitration in accordance with the Commercial Arbitration Rules of the American Arbitration Association at Denver, Colorado and that the award of the arbitrator(s) may be entered as a judgment of the Jefferson County/District Court pursuant to C.R.S. Section 13-22-201, et_ sea. Respectfully Submitted on this 31 st day of July, 2017: COUNCE KEMPER SPECIALTY CONTRACTORS, INC. r Authorized Representative Proposal Accepted and Work is Hereby Authorized: CLIENT AuthopiAtion Signature i Date: CONTRACT: Please retain one (1) signed copy of this Contract for your files and return the other signed copy to Counce Kemper. 2013- 1 CHRIS ELECTRIC 1 >> P 2/4 4 � nor . ° rw... NEM 4 Fit !t # 2 , PIM W rwl �+ a ♦ t p PW*i o ` ple "all hIghlighted,aron on both sides of tl[ls "f . Inoomplito applications may not be oo. *** • • + w - ----- �- a 0 l . 0 * 0 1; tt: t± I I M`" 10 -: • M: +4 T FffA M ha ; K Ofty Lice # Comploteall information .n.. B OTH sides of this form 2 013-09-0 9 „ t q y ��r (R `fib S o Page 1 of 1 Subj: Date: From: To: CC: FW: permit 093027 8/5/2010 9:32:17 A.M. Pacific Daylight Time hart unitedcoatinos j ci.wheatridge.co RBKEN Per --- V�� - - -- Good Morning Mr. Schumacher, �` E AUG 1 6 2010 At the request of Roger Kemper I had one of my Independent United Coating Representatives, while traveling thru Denver, visit the jobsite located at 30 Hillside Drive in Wheat Ridge, CO. V His report to me was that the installation of the polyurethane foam and coating system looked very good. The application of the foam showed positive drainage and the coating application was uniform and within United' specifications. Issuance of the 10 Year Warranty will be expedited once the "Request for Warranty" form is recieved by United, if in fact it hasn't already. Sincerily, Steve Hart�� ``SJ Regional Sales Manager ti United Coatings y From: Steve Hart Sent: Tuesday, July 27, 2010 6:27 AM To: jschumacher @ci.wheatridge.co.us' Cc: 'RBKEMPER @aol.com' Subject: permit 093027 Good Morning Mr. Schumacher, \ My name is Steve Hart and I am the Regional Sales Manager for United Coatings. I am writing at the request of one of my Certified Applicators, Roger Kemper in regards to permit # 093027, the Cliff Hoffman residence located at.30 Hillside Drive, Wheat Ridge, CO. This is in reference to a roof application applied on this project. I have reviewed the application process of both the polyurethane foam as well as the protective coating system, Diathon, that was followed and utilized on this project. The application rates and procedures meet and exceed the requirements of United Coatings and qualify for issuance of United's 10 Year Warranty. Counce- Kemper has been a Certified Applicator of United Coatings Roofing Systems for over 30 years. If you have any questions or require any additional information please do not hesitate to call me. Thank You, Steve Hart United Coatings Regional Sales Manager 509- 998 -6270 This electronic message and all of its contents contain information from Quest Specialty Chemicals, Inc. or one of its affiliated entities. Such information may be confidential or otherwise protected from disclosure and may be used only by the intended recipient. Any disclosure, copying, distribution or use of the contents of this message by anyone other than the intended recipient is prohibited. If you have received this electronic .message in error, please notify us immediately at ((800)966 -7580) and destroy the original message and all copies. ♦ A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: PI t )lh b Job Address: "Db Fh WVJ C f N'. Permit Number: i' (i I w2 ❑ No one available for inspection: Time J,' 6c? AM/ M , Re- Inspection required: Yes LoJ, `When corrections // have been made, calf for re- inspection at 303 -234 -5933 Date: - Rio Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE' Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: F. va ~L Aw,t Job Address: J3 { /i /StvF D.e Permit Number: ry 9.3o.27 x `/'77 �CIJ'1 /1 i7� ,� G.C7T�1C. .7.�177Y/ f�i�7li l /�� GTiJ�i �.`°/Jf /Jr /:ra>t7- 1I Sl�f4'/L1✓frd' 7�s A4 1,2 AYA< A- 0 No one available for inspection: Time `/ AM /f!4)� Re- inspection required: , es No *When corrections have been made, call for re at at 303 - 234 - 5933 Date: Z�/9 is inspecto DO N07-REMOVE-THISS MOTICE t T NO: !101623 ISSUED:: 0.6/24/2010 TnT UCC. IA VTTTCTTV '11D 111TIll ,X1 /,, /'t, COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: BUILDING INSPECTION LINE - 303 -234 -5933 Date: ti P CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303 -- 22 335 - 2355) T7,/� �/ Cp, ••M1pCJ AFILl CA 11. Y Property Owner: C-' "'-- Property Address: ..F0 Contractor License No.: /7/ 7� / Company: �e // / /&/,# l' hQ £ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; Nat all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge auilding Cade (U.S.C) and all other applicable Wheat Ridge Ordinances, for v^.y�oorr'[� /ynder this per Description: 9�� �116eh Sq. Ft. added jol�2� Phone Phone: J�17 Construction Valuer /,30D" Permit Fee:$ G </O� Plan Review Fee:$ 41t Use Tax: .S Total:S 6390 l2� /a�e�hT youoad 97 BUILDING DEPARTMENT USE ONLY SIC: Sq.FL: Z ONING P �/.?7`0 BUILDING I PUBLIC W� we Occupar Q � tories Residential Units: .514F Ile a/ D� U r9��leaf Electrical i b: /717�;l Mechanical License No: Company G✓,��s Company: Expiration Expiration Date: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the Slate of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been orwill be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. Chief Building Official 1 "' 1 1 , A"., 0 V�Tl , �- M COMMUNITY DEVELOPMENT DEPARTMENT { ct W � Ea J q BUILDING INSPECTION LINE - 303. 234.5933 g CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303- 235 -2855) '` dfiA °J PPLICATION Property Owner: Property Address: 30 Contractor License No.: /'IJ /7� / �1 Company: �� !/ � /GH OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. (OW NER)(CONTRACTOR): Description: l � Lf � 11eA -mo Sq. Ft. added Building Permit Number: G b N Date: Phone30� �,�a -��L3 PIt one:�03 Construction Value:$ 1y00 ° Permit Fee:$ elo °o Plan Review Fee:$ X 20 Use Tax - S a� Total:$ b�r- elz !% o �9Tl/ Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: 0) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notiry the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. - (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. Chief Building Official Electrical License No: Plumbing License No: /7/�� Mechanical License No: Company: Company: Company: ' City of Wheat Ridge Residential Roofing PERMIT - 093027 PERMIT NO: 093027 'ISSUED:: 10/06/2009 JOB ADDRESS: 30 HILLSIDE DR `EXPIRES: 04/04/2010 DESCRIPTION:' sloped foam with acrylic coat: overlay'. over flat. Smooth BUR ***CONTACTS owner 303/232-6463 Clifford Hoffman gc 970/535-9666 Roger Kemper 09-0379 Counce Kemper Specialty Contra PARCEL INFO ZONE CODE: UA USE: UA SUBDIVISION:I 0676. BLOCK/LOT#: 0/. FEE SUMMARY ESTIMATED PROJECT VALUATION: 18,200.00 FEES Permit Fee 399.50 Total Valuation ,pp we Use -Tax ° e 327.60 TOTAL 727.10 , 1"/".2r"_` .onditions• Per manufacturer specifications. Subject to field insp. 3oard sheathing spaced more than a 1/2 of an inch apart requires plywood overlay Dn entire roof. ice and water shield required from.'eave edge to 21 inside` =_xteriorwalls. a**Contractor/Property owner shall provide 'ladder(s) secured in place for inpsections.-- I hereby certify that the setback distances :proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements. shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application d at I a ume full responsibility for compliance with the wheat. Ridge Building Code.. (I.B.C) and all other' applicab eat.'R' a ina~ for. work under this permit. Plans :subject to field inspection. Signature This permit was issued in accordance with the provisions' set forth in your application and is subject to the laws of the. State of Colorado and to the Zoning` Regulations and Building Codes of wheat Ridge, Colorado or any other applicable ordinances of the city. This permit shall expire 180 days from the issue date. Requests for an extension must be`. received prior to exoiration r a or, nor lation. DAY. ' City of Wheat Ridge Building Division Date: m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Plan OO~ORPOO Inspection Line: 303-234-5933 Permit Building Permit Application Property Address 30 11- i D R1 / I`!-~~~CRlcap~Coo SOOM5- Property Owner (please print): CL I r F0 FFIA A 1 / Phone: 80 1 M Mailing Address: (if different than property address) Address: c5ATh o City, State, Zip: Contractor: CCJQA/CZ tCEMPER SP CCIALT,' (,26 Al T#'Wot 5 /~fC CELL s ''c , Contractor License 0 q r-c Phone: 13p -~66 c~ ~Q _ ~T yr.~~ Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: ADDroval: Use of space (description): Description of work: p01-1YflRE7-I11;N6 r6fJn! wi(ri~ tAl,cw C'64-r ilvat HCRt(L/C (1CrATIA I)INTNa4„ I,t15TALL6,i) &L,&/Z 5IN6LC- L r}d o F 77115 to T// /~U TYPz R66F; Sq. Ft:LL d: 5JW~Squares BTU's Ga Construction value: $ ' AO vi (as calculated per the Building valuation Data sheet) Plan Review (due at time of submittal): $ NdTLr roAln 5a.o&~r~% 'T307 ORAJAIJ466 A, Ions Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to r 'ns ection. CIRLCE ONE:: (OWNER (CONTRACTOR) or PERSONAL REPRESENT (O R) O TRATOR) PRINT NAME: C SIGNATURE: 17 Date: /