HomeMy WebLinkAbout3575 Estes StreetCity of Wheat Ridge Residential Carport PERMIT - 202002205 PERMIT NO: 202002205 ISSUED: 11/19/2020 JOB ADDRESS: 3575 Estes St EXPIRES: 11/19/2021 JOB DESCRIPTION: SWO Construct carport - 168 sq ft total *** CONTACTS *** OWNER ( 7 2 0) 7 0 5- 5 6 9 7 BROOKS SHANA M GC (303)783-1363 MIKE MCGUIRE 090276 CONCREATIONS INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 81000.00 FEES Total Valuation 0.00 Plan Review Fee 112.19 Use Tax 168.00 Permit Fee 172.60 Investigative Fees 172.60 ** TOTAL ** 625.39 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Carport PERMIT - 202002205 202002205 ISSUED: 3575 Estes St EXPIRES: SWO Construct carport - 168 sq ft total 11/19/2020 11/19/2021 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include al entities entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Accessory Structure (Garage, Shed over 120 sq ft, Gazebo) Date: Monday, October 26, 2020 6:02:10 PM Residential Accessory Structure (Garage, Shed over 120 sq ft, Gazebo) THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 3575 Estes St. Property Owner Name Shana M. Brooks Property Owner Phone 720-705-5697 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email shanabrooks@comcast.net Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Electronic Payment Form.odf CONTRACTOR INFORMATION Contractor Business Concreations Inc. Name Wheat Ridge 090276 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 3038802068 Number (enter WITH dashes, eg 303-123- 4567) Contact Email Address concreationsdenver@gmail.com for Questions/Comments Retype Contractor concreationsdenver@gmail.com Email Address DESCRIPTION OF WORK Detailed Scope of Work - Example: Detached Garage with Electrical; Unconditioned shed Square Footage of Accessory Structure Engineering Letters and Other Letter Size Attachments Construction Plans scanned on 11'x17" or larger Building of a Carport im Enaineer Letter. odf 3575 Estes St. Plans.odf Project Value (contract 8,000 value or cost of ALL $8,000 valuation is materials and labor) OK Mlei uG\lI]:».7011110101:1Ma IMI 01.ln[e1Ga01owmel:1=1r�d:10r1 I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Michael McGuire Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. S eAu.e, Mobile: 3o3 c o �•- 1%90� ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Projects are Subject to Field Inspections � 4 t7. r k Y S Reviewed for Zoning Compliance by the ' City of Wheat Ridge Planning Division = r APPROVED BY: DATE: 11/6/2020 COMMENTS: complies with R-2 setbacks verified in field City ofe W heat lge COMMUNITY DEVELOPMENT �;� APPROVED P. Reviewed for Code Compliance Randy Slusser 11/17/2020 Plans Examiner Date Validity of m mil: The Msmaxe of o pemftt ar gporovai of phans sp C4kaQOM and cnmporotwns shoN nat be o prrmtia % yr on opprwa o j, my naronon b any of Me provlslons'E' Me bode q coo, or of ops City asdinm x permM pffl m v to pm o.ftffly to HolaNt or canal tM pwwans of the sumov w0aPraAerommnasofMeotyshaftwtbewHd { P 9 Project Addre<. Site contact:_ n E-mail: t , Estimator: Notes: S r S eAu.e, Mobile: 3o3 c o �•- 1%90� ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Projects are Subject to Field Inspections � 4 t7. r k Y S Reviewed for Zoning Compliance by the ' City of Wheat Ridge Planning Division = r APPROVED BY: DATE: 11/6/2020 COMMENTS: complies with R-2 setbacks verified in field City ofe W heat lge COMMUNITY DEVELOPMENT �;� APPROVED P. Reviewed for Code Compliance Randy Slusser 11/17/2020 Plans Examiner Date Validity of m mil: The Msmaxe of o pemftt ar gporovai of phans sp C4kaQOM and cnmporotwns shoN nat be o prrmtia % yr on opprwa o j, my naronon b any of Me provlslons'E' Me bode q coo, or of ops City asdinm x permM pffl m v to pm o.ftffly to HolaNt or canal tM pwwans of the sumov w0aPraAerommnasofMeotyshaftwtbewHd { P 9 9/3113 1. Fill in the blanks with dimensions and materials which -� � � � r' S " will be used to build the structure. Please print legibly, 2. lndicate in the check boxes which details from page 4 will be used. Please note if any of the sides of your carport addition are closer than 5'-0" to the property tine, that side of the carport must be enclosed with a solid 1. hour fire rated wall as shown in Alternate Details B and C. You must however, keep at least two sides of the carport open to conform to the building code requirements. Zoning approval is required. 8. Roofing to be installed per manufacturer's instructions, including low slope application and required inspections made. Roof coveri.n D, (example; Class A Size ancmount of Lai 1� Z X l L4 J (exempla: Two 1/n 4 UP tags W O.Cj s Section r UnderiaymentTLr-,- >r� �� ;,���Aw h 1 (31rel�'i Detail A Detail B {3 Alternate A :1 Aftemate B J Other (provide detail) isee page 4) Existina (see page 4) building man Maximum/ rise 7 3/4" at top of dour PJ Detj threshold J Alternate C i (see page 4) isolate from Slab - _..Slope Concrete Slab Minimum Diameter Pier 8 (size determined by load) Sheathing 'lL bc�ws 2x_lrafters spaced] °° O.C. (example; 2 x 8 roars spaced 24" O.C.) Note: Walls, posts, and overhangs closer than 5'to the )veline to be 1 hr. rated Al.,� No closer than 2 feet to property line Beam splices to occur over posts with 1 jig" bearing ..... i,-4.. "x�"beam 6-8" minimum 3'-0" minimum Span_e I� (example: 12V) Siding N A (for MWrials a 0*d °IX—L"posts (example: 4°x4") spaced ' apart Footing , `L _ "x 3 0 11 (rarANamale C only; This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2012 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. Whea'Midge Building Division 9/9/13 Existing roof ratters or trusses Lap underlayment a minimum of 18' under existing roofing felts 1 Galvanized metal joist or ratter hangers Solid 2x blocking on 2x12 or greater Extend underlayrment from Roof tie downs required new roof a minimum of 1 a` . onto existing roof ----' ' - Remove existing fascia ' `-" Existing Cont. 2x ledger -w---..` wal' Existing Roof Secure ledger to wall with lag screws @ 16' O.G. (remove existing shingles Locate lag Screws to penetrate top plate or studs Note: Remove brick veneer at top cf wall I I Cont. 2x6 secured to existing roof Witt; Existing wall before installing continuous 2x ledger fasteners at each rafter or truss e jAlternateDetail .- Solid 2x blocking on 2xf 2 or greater olid 2x f€re blocking on 2x12 or greater. ', /i Roo± be downs required} wns required -- -� 2x tacia � _ `X" exterior k m sheathing ' Lata d metal '�--` connector - -_ ) No closer than 2 feet to property line metal litGalvanized TWO i,ayerb UExterior siding _ ,yp xpost/beano connector ween posts exterior gypsum board soffit rg, 16' O.C. Less than 5' fa property #iris -- TreatPrf or decay Bottom plate shall Infill between posts i €resistive post be treated wood w/ 2x4's @ 16" 0,C. Minimum 3 1/2" -, i Galvanized i Minimum 3 1/2° concrete slab column base V concrete s#ab 1191 Galvanized V1N` w/ spacer to d - column base w/ 1 concrete spacer to concrete Isolate Isolate from Slab — Anchor bolt from Slab Anchor bolt 7" minimum !" minimum $„ minimum 3'-0„ penetration, Check local penetration diameter minimum concrete building 3'-0° department for minimum caisson Swelling sails caissons may € be required. # Footing 'moi ;�..._..._.._...._..�....i This handout was developed by the Colorado Chapter of the I j� International Code Council as a basic plan submittal under the 2012 International Residential Code. €t is rich intended to cover all circumstances- Check with your Department of Building Safety for additional requirements. Cit Building Division AL1 EN CONSULTING ENGINEERS, LLC Alpen Consulting Engineers, LLC 7475 West 5`' Avenue, Suite 204 Lakewood, CO 80226 720-550-6790 October 21, 2020 Project Information: 3575 Estes Street Wheat Ridge, CO 80033 To whom it may concern, At your request, our office performed a site visit on October 21, 2020 to observe and provide professional opinions on a carport on east side of the home. Architectural and Structural plans were not available for our review. The conclusions and recommendations presented in this report are based on the visual observations made as well as our professional knowledge and experience in the engineering field and construction practices in the Colorado Front Range. The main entrance of the existing house is assumed to face east. The existing house is a single story structure. The roof, floors and wall framing consist of wood framed members. The exterior walls are finished with panel siding. Our observations & recommendations are as follows: 1. Observation: On the east side of the carport blocking panels were not installed between roof joist. • Recommendation: We recommend full depth blocking panels @ 16" o.c. between all roof joists. 2. Observation: On the west side of the carport uplift connectors were not installed between roof joist and existing house. • Recommendation: We recommend installing Simpson H4 hurricane ties at each 2x8 joist. 3. Observation: On the east side of the carport the southernmost uplift connector was not installed between the roof joist and the 4x6 drop beam. • Recommendation: We recommend installing Simpson H1 or H2.5T hurricane ties. City of Wheat Ridge Building Division ALPEN CONS UL11NG ENGINEERS, LLC Alpen Consulting Engineers, LLC 7475 West 5`" Avenue, Suite 204 Lakewood, CO 80226 720-550-6790 4. Observation: The 4x6 drop beam is not adequately sized to meet the code required loads. • Recommendation: Sister on a 4x6 Doug fir select structural member with (2) rows of 3/8" bead of construction adhesive 1" from the top and 1" from the bottom of the member. Use (1) row of Simpson SDS1/4x6" screws centered in the member at 6"o.c. If the above recommendations are implemented the structure will be capable of supporting the code required dead and live loads. This report should not be considered a warranty or guarantee, implied or expressed, of the home in general, the building superstructure, or the foundation system. Structures and foundation systems may be severely impacted by changes in climate, land -use, etc. The conclusions presented in this report are based on conditions at the time of the observation. Should questions arise, or if further information is required, please contact our office. Sincerely, Alpen Consulting Engineers, LLC Digitally signed by Patrick J. Kervin Patrick DN: cn=Patrick J. Kervin, o=Alpen Consulting J. Engineers, ou, Ke ry i n email=Patrick@alpence.co M, c=US Date: 2020.10.21 15:17:45, -06'00' Patrick J. Kervin, P.E. Date: 2020.10.21 Principal 720-732-2544 City of Wheat Ridge Building Division t�k� ,' i 7� :� INSPECTION REG INSPECTION ONLINE FORM: hftp://www.ci.wheatridge.co.us/form-- INSPECTION INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** I Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Sewer Service Concrete Encased Ground (CEG) Mid -Roof- Plumbing Foundation / P.E. Letter Lath / Wall Tie .�I�rRf-�YTTS'JT��1�l:IT7a.71\.\-�l/.\lY■��■��.�'�•\�1�\rIJ■■ti��lal�■twin Underground/Slab Inspections Date Inspector Comments Initials Electrical Wall Sheathing Sewer Service Mid -Roof- Plumbing � ���w��s�r��e���emr�rr-r_r_�-.a-�r=�rra�■:\tic.i.�u�i.\r��r■.\.���>.•\�1�1/�\�/■��l���l�a•=\�l�l'l•i ■�1�1 �1�1R\\L■[�� vv ■w� vv�v■ Rough Inspections Date -- Inspector Initials --- - Comments Wall Sheathing Mid -Roof- Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — mease De sure inat rougn unsNecuuns evu uumv uioV111 ulc 1 1.6 �„•,, . u,, . �.••� • •�•• by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PERMIT - 201702573 PERMIT NO: 201702573 ISSUED: 06/26/2017 JOB ADDRESS: 3475 Estes ST EXPIRES: 06/26/2018 JOB DESCRIPTION: Residential Re -roof to install GAF Timberline HD asphalt shingles with 35.64 Sq. *** CONTACTS *** OWNER (303)237-8630 MC COY JIMMIE ALLEN SUB (303)233-7663 Ben McFerron 070157 Premier Roofing Company *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,159.48 FEES Total Valuation 0.00 Use Tax 192.35 Permit Fee 204.30 ** TOTAL ** 396.65 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding Al/2-inch exists. Asphalt shingles are required co be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€T"s installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 1�+L- ��Oo t`' Job Address: ��J r�Tltl`p ;� Permit Number: % e1 0 611 IL5 PUT- ❑ No one available for inspection: Time M Re -Inspection required: Yes No' When corrections have been made, call for re -inspection at 303 -234 - Date: Inspector: "`fin' la DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line _.(�.00�(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: 2�1 "1Gj ❑ No one available for inspection: Time _ AM/PM Re -Inspection required: Yes No When corrections have been made, call for e-inspec�tiionnaat 303-2_ 34-5933 Date:12 �4 Irl Inspector: 1 1 r- 042t..., DO NOT REMOVE THIS NOT/CE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ivy [ 0 V-DC>F- Job Address: 55-15' Permit Number: '1? 0M ®?)qV'5 ❑ No one available for inspection: Time -W AMX@) Re -Inspection required: Yes No When corrections have been made, call for,re-inspection at 303-234-5933 Date: I `O Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201708925 PERMIT NO: 201708925 ISSUED: 11/07/2017 JOB ADDRESS: 3575 Estes ST EXPIRES: 11/07/2018 JOB DESCRIPTION: Permit for residential reroof: Installing 18 squares Malarkey Highlander asphalt shingles 5/12 pitch *** CONTACTS *** OWNER (303)423-0980 NORMAN BERNADETTE MARIE SUB (303)425-7531 John Borfitz 019983 J & K Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,527.00 FEES Total Valuation 0.00 Use Tax 158.07 Permit Fee 172.60 ** TOTAL ** 330.67 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report. AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201708925 PERMIT NO: 201708925 ISSUED: 11/07/2017 JOB ADDRESS: 3575 Estes ST EXPIRES: 11/07/2018 JOB DESCRIPTION: Permit for residential reroof: Installing 18 squares Malarkey Highlander asphalt shingles 5/12 pitch I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications. applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner ofthe property and am authorized to obtain this permit and perform the work described and approved in conjunction ti ith this permit. I further attest that I am legally authorized to include al[ entities named within this document as parties to the work to he perto ed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specitications. 1X/a. Signature of (c� or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 1 If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees andprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of' the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. '"�� 6, The issuance or ting of a hall not e construed to be a permit for, or an approval of, any violation of any provision of any applicable co ance r ib of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. CONTRACT T Q' • JK Roofing BBB. 13000 W. 43rd Drive Ndtvs"20177p Golden, CO 80403 ►sea - Phone: 303-425-7531 • Fax: 303-425-1562 www.jkroofing.com Representative.Fr� Yas�re-^A . t Contact, " 6 0 - SYSS Date 20 Name �t/bJz4o— Nor ma in Phone C 3�-gZ3-V tgo email I) el Address 35757 G S 4e"S City Whu 7 1� i O�Q zip 2003 Pinnacol Assurance Cincinnati Specialty Underwriters 303-361-4000 303-653-0023 Workers Compensation Insurance General Liability Insurance Policy #4079290 Policy #CS00061742 LABOR AND MATERIAL SPECIFICATIONS, TERMS, AND CONDITIONS. PLEASE READ CAREFULLY: Recover roof with M &w _ Cit � h !d �/ ❑ Extra work 0 11 Color of shingles OX-OCe ro( C1 re— t4 -1 S+ Pd b � E, Manufacturer's Warranty L1ed� TeEl ar off �-�ye 1rro�f /dr...+ ind �-e-d` C4 ►^'1(� Z ❑ Install Underlayment 151b 1 ❑ Double all Eaves A- (�,b �✓� c5 G 4.. The property owner is is not_ using proceeds from d property and casualty insurance policy. ❑ Re -Flash Chimney and/or Skylights C hi'"^ r�� Lj.�- ,, /,. /�N El New Valleys ��NS L" ; ✓ a, ! td I'd l � ��y Yf [ di% $ --7' /1 G ❑ Replace Ridge E Z 1` 1dLqA d Cd / V f S Jd El ,n-��r>`..�p� �+ L)C,^+ $ ❑ Galvanized Fasteners �, Ada; S tKJtr f -6 a lett, r` "'% �Sd L y $ ❑ Replace A 1\ Plumbing Jacks o0 ❑ Paint roof stacks to match ' 1 ❑ Install z- Met I Edging W h' ❑ Patio or Flat roof • / v �/ 1 Year Warranty on labor J & K Roofing to furnish all material and labor `+ Permit: _ X Included NOT Included Clean-up debris and haul off all trash from roof Roll yard with magnetic roller Gutters cleaned of roofing debris CC Decking Repairs $ 60 per J -� -i Hidden Layers (tear off) $u� per layer L ;,b er 4-y ",44-(4d/ F!V M167///40d f (Cam&j I (Policy Number) _ 3,5S-6 6Soo - l lCiam k7 04 -tor) (Mortgage Loan Number) Deductible if applicable $ ba-, Per Colorado State Law CRS § 6-22-105 which states; 100% the responsibility of the homeowner to pay this amount. J & K Roofing will not reimburse or promise to reimburse in whole or in part any amount of the deductible. Estimated Start Date 1/ ^ S ' P TOTAL ESTIMATE $ O� -rd Xe -s ALL PROPOSALS ARE SUBJECT TO MANAGEMENT APPROVAL 7,7 J&K Representati:� /y Date_Y.04f= Homeow — ate 49 -7 Homeown Expiration Date-----,--- _ _ __ t- _ --- - You have the right to recind this contract and obtain a full refund of any deposit within 72 hours after entering the contract. If you plan to use the ° proceeds from a property and casualty insurance policy to pay for the roofing work, you may rescind this contract within 72 hours after receiving written notice from your insurance carrier that your claim has been denied in whole or in part. However, J&K Roofing is entitled to retain payments or - deposits to compensate for roofing work actually performed in a workmanlike manner consistent with standard roofing practices. PLEASE SEE REVERSE SIDE FOR IMPORTANT INFORMATION Antoinette Kulick a on 0 `� D-5 From: no-reply@ci.wheatridge.co.us Sent: Tuesday, November 7, 2017 12:49 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN C REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? j. How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 3575 Estes St Property Owner Name Bernadette Norman Property Owner Phone 303-423-0980 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Field not completed. Address � 3 0 t 21 Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Yes Norman contract.pdf CONTRACTOR INFORMATION Contractor Business J & K Roofing Name Contractor's License 019983 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-425-7531 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 13000 W. 43rd Dr., Golden Co 80403 (Primary address of your business) Contractor Email Address kathyv@jkroofing.com Retype Contractor Email kathyv@jkroofing.com Address DESCRIPTION OF WORK TOTAL SQUARES of 18 the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or both? (check all that apply) 7527 No Pitched roof (2:12 pitch or greater) 22 What is the specific pitch 5/12 of the PITCHED roof? How many squares are 18 part of the PITCHED roof? Describe the roofing Malarkey Highlander materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof: Provide any additional House detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application 23 and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Kathy Vendegna Email not displaying correctly? View it in your browser. 24 Building Permit Application (Complete all highlighted areas) Property Address Property Owner (please print): evrt -, 6- A e- em o4-, Phone 26 3 - _01 Mailing Address: (if different than property address) City License # City License # City License # 5WLDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS' OCCUPANCY: Reviewer: F'IRE DEPART MENT;: C: approvedwl comments 1: disapproved E _ no review required I Bldg Valuation: 5 c3I r ?,DO amp SWV - INSPECTION RECORD INSPECTION REQUEST LINE: (303) 234 -5933 Occu ap cy/Tvne Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 3:00 p.m. to receive an inspection the following business day. Must Sign ALL Spaces pertinent to this project *spector Foundation Date Inspector Initials Comments Monolithic Slab Caissons Concrete Encased Ground (CEG) Footing /Stemwall P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground /Slab Inspections Date Inspector Initials Comments Electrical (Underground) Sewer Service (Underground) Water Service (Underground) Plumbing (Below / In -slab) Heating (Below/ In -slab) _ Do Not Cover Under round or Below /In -Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Roof Sheathing Lath /Wall Tie Rough Electric Rough Plumbing Rough Mechanical Gas Piping Do Not Proceed Rough Framing Without Approval Of Above Rough Inspections Insulation Drywall Screw / Nail Final Inspections ate Inspector Initia Comments Final Electrical 5 Final Plumbing Final Mechanical Roof Final Building / Frame Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking ROW & Drainage / Public Works Dept. inspections call 303 - 235 -2846. For ROW and drainage inspections call 303 - 235 -2861. For fire inspections Fire Inspection / Fire Protection Dist. contact the Fire Protection District for your project. * *Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. W% , . , UVC111t,y tJ tvvt Permitted untn A certificate of Occupancy Is Issued Protect This Card From The Weather f ❑ Nd avaifable for inspection: Ti AM /PM Re- Inspection required: Yes ; No z _ When corrections have been mad all frorr fefl pec ion at 303 - 234 -5933 f Date: Inspector: DO NOT REMOVE THI NOTICE " ' City of Wheat Ridge - r Residential Electric PERMIT - 110814 PERMIT NO: 110814 ISSUED: 07/14/2011 JOB ADDRESS: 3575 ESTES ST EXPIRES: 07/13/2012 DESCRIPTION: Replace service with 200 Amp *** CONTACTS * ** owner 303/423 -0980 Bernie Norman gc 303/400 -4321 Edward Jueschke 02 -1943 SJO Electric LLC ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0600 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 2,250.00 FEES Permit Fee 93.35 Total Valuation .00 Use Tax 40.50 I to ** TOTAL ** 133.85 Conditions: Must comply w/ 2006 IRC & 2005 NEC. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been auth riz conjunction by the legal owner of the property and am authorized to obtain this permit and perform the work described and p ved in with this permit. I further attest that I am legally authorized to include all entities named w' s document as parties to the work to be performed and that all work to be performed is disclosed in this docu en o ts' accompanying approved plans and specification Signature of/ OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee, 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Bu ffical Date INSPECTION RE ST INE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST OE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of WheatRlde COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303- 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application property Address: 3 75� L 5 TG Property Owner (please print): lfga n,,� Mailing Address: (if different than property address) Address: Date: -7�1`G4r'1 Plan # Permit# 116zP1 Phone: q23. 6W'0 City, State, Zip: /`f"✓U aCi Contractor: � `�� `�/ -fi/ `e-- Contractors City License #: 0. q' Phone: T. 5uti Contractors: Electncal: Plumbin 9. : Mechanical: City License # bescrlp'tlon a #worlii City License # City License # v' 1 ?&-a Contra tyyalue: s / Cv' 1 , � Review Pee (due at time of submittal): Squares BTU's Gallons _ Amps � Sq Ft. $ f 5 3` 9 S OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR � Or (AUTHORIZED REPRESENTATIVE) f O ER) (CONTRACTOR) PRINT NAME. **?7 Cc! D+° `''� SIGNATURE: � DATE:. ^ r ': rr y � '. ,x �,' �l'k ' .r it „{ `� bEP,�►RTIVIENT US`E'O z.�s '' � r � .r- , a� ��,�:' fi � �`' t ✓ ra i^ "i'rT �t � l/ t T� Vr � rc.�Z:u3�� ^r"� v t� y ,Fv� ✓� aZONI�NG COMMENTS � ✓°,w � � ,� ^v dy � r n'S � � �'� � f l'?� � .' r` ✓ � C"i1 i �' � z ii'� ,:' Bldg Valuation: A , CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office * (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type Job Address �? 7-4' e ron—e 57` Permit Number Z! ®1�po� r2E ♦��4' City of Wheat Ridge Residential Mechanic PERMIT - 110106 PERMIT NO: 110106 JOB ADDRESS: 3575 ESTES ST DESCRIPTION: Replace 75,000 btu furnace ISSUED: 02/03/2011 EXPIRES: 02/03/2012 * ** CONTACTS * ** owner 303/420 -0812 Wilson sub 303/431 -8015 Edward Terranova 01 -9402 Aaark Heating & Air Conditioni ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0804 BLOCK /LOT##: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 1,800.00 FEES Permit Fee 40.00 s Total Valuation .00 �DI�b0�y1$ Use Tax 32.40 W yj ** TOTAL ** 72.40 Conditions: Work shall comply with 2006 IRC & 2005 NEC. Per IRC Sec. R313, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. Carbon Monoxide detectors are required to be installed within fifteen(15) feet outside the entrance to each sleeping room. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in thpsi document and /or its` accompanying approved plans and specifications. Signature of OWNER br CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to fie on. Signatur of Met Building Offical Date INSPECTION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. tz� ,g�r� City of �`ys _- COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Officer 303- 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Property Owner (please print): Mailing Address: (if different than property address) Date: Plan # Permit # l Uh l Building Permit Application Phone: Address City, State, Zip: y d i/+ i 2 - 3 J , 0 -" : Contractors Citv License M Z . Phone: Mechanical: City License # Contract Value: $ Z'FOO (G - - - Electrical: City License # Plumbing: City License # Descrtptlon `of �rork Review Fee (due at time of submittal) Squares BTU' Gallons Amps Sq Ft. I $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) (CONTRACTOR) or (A OTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME A 4 4' — SIGNATURE: Bldg Valuation: ♦ ♦ CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 4 0 Job Address: ` a` tea? F Permit Number: J 'r ❑ No one available for inspecti~ an`Time AM/PM Re-Inspection required: Ye No When corrections have been made, call for,~redns action at 303-234-5933 Date: /6 -Oct Inspector: , /I"jGJ~JCj~ DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax IPISPECTION NOTICE r Inspection Type: Job Address• - f FCZ_7._S Permit Number: 02 / 7 A i ❑ No one available for inspection: -Time AM/PM Re-Inspection required: Yes No "When corrections have been made, call for re nspectfon at 303-234-5933 Date:/(9 -6 '~2_ Inspector: A DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: ROO E v~ J A I Job Address: 3 SST S Permit Number: 0"~Lk-- l- Ce-VAL ~ F- 4 S 4)NC~ rs-I / 14I1vr~~Y4A)1) $E -Al e'ni>At~:4t-e45U N~ t ty t; g: it Ii ❑ No one available for inspection: Time AM/PM Re-Inspection required: es No "When corrections have been made, call for re inspec n at 303-234.5933 Date: -~1 ~nr Inspector: F DO NOT REMOVE THIS NOTICE ♦ ♦ CITY OF WHEAT RIDGE Building Inspection Division r (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax NOTICE Inspection Type: A � !) 1L Job Address: 3.5 E5 �- Permit Number: ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes No �' When corrections have been made, ca ll -ins ction at 234 -5933 Date: —' `G Inspector DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE r Building Inspection Division f (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: M IN LOJ7- Job Address: -3.S 15 t Permit Number: 4q i 1 E SA) 5 LJ) 176 i= `" S /007 x�Ir d Wll W.5 P r-- r--y 7 ir5 f,�Ac. , ❑ No one available for inspection: Time AM /PM Re- Inspection required: , es No "When corrections have been e, callr re -i pection at 303 - 2345933 Date: Inspector: , DO NOT REMOVE THIS NOTICE " ' City of Wheat Ridge Residential Roofing PERMIT - 091761 PERMIT 'NO: ` 091761 ISSUED: 08/28/2009 JOB ADDRESS:. 3575. ESTES ST EXPIRES: 02/24/2010 DESCRIPTION:: Reroof=18 sqs ***CONTACTS.*** owner George Vondignia sub 720/382-9294 Fred Salazar 09-0278 Cherry Creek Roofing PARCEL.. INFO ZONE CODE: UA - USE: UA SUBDIVISION: 0600. BLOCK/LOT#: 0/ **FEE SUMMARY ESTIMATED. PROJECT VALUATION: 4,500.00.. -.FEES. Permit Fee 144.70 Total Valuation .00 Use Tax G~.O~ 81 .00 **.TOTAL 225.70 43 Conditions: 6 nail installation& mid-roof inspection required. Board :sheathing spaced more thanes 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water .shield required from eave edge to 2' inside exterior walls. Subject to field inspections. I hereby certify that the setback distances proposed by this permit application. are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record;: that all measurements shown, and allegations made are accurate; that I. have read and :agree to abide by all conditions printed on this application and. that I assume full responsibility for compliance. with the Wheat Ridge Building. Code .(I.B.C).and all other applicable Wheat idg Ordinances, for work under this permit. Plans subject. to field inspection. Signature of c t ac /o er 'date - L. This pe was issued. in accordance with the provisions set forth in your application and is subject to the laws of the state of :Colorado and to the zoning Regulations and Building. Codes of Wheat Ridge;. Colorado or any other applicable :ordinances of the City:. This. permit shall expire 180. days from the issue date. Requests for an extension must be :received prior to expiration date. An extension may. be. granted at the discretion of the :Building Official. 3. If this permit expires,a new permit may be acquired for a fee of :one-half the amount normally required, provided no changes have been. or will be made in the original plans andspecifications and any :suspension or abandonment has not .'.exceeded one (1) year. If changes have been or of suspension or abandonment exceeds one (1) year,. full fees shall be paid for anew permit, 4. No work of any. manner shall be done that will change the natural flow of water causinga drainage problem. 5. Contractor notify the Building. Inspector twenty-four (24) hours in advance for all inspections and. shall. receive written approval on inspection card before' proceeding with successive: phases : of the :job. The issuance of a permit or the approval of 'drawings. and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building: codes or any other. ordinance, law, rule or regulation. All plan revie is ject to field. inspections. signature of ief ilding Official :.date CNSPECTI REQUEST LINE: (303)234-$933 BUILDING OFFICE: (303)235-285S ZEQUESTS MUST: BE :MADE BY 3PM ANY BUSINESS DAY.. FOR.. INSPECTION THE 'FOLLOWING BUSINESS DAY. ~oF W"E"r City of Wheat Ridge Building Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 o Inspection Line: 303-234-5933 O<ORPO Building Permit Application Property Address: Property Owner (please print): C e cl V-~Z1 L Mailing Address: (if different than property address) Address: Date: 7: p P''F/~C) Plan A/D. Permit O- l l 76, Phone: Contractor: G `lcar a c"_r•r/'? ✓ryt>~ «r"` Contractor License Phone: Sub Con'tractors': Electrical City License Company: Plumbing City license#: Company . Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): ° ✓ Construction Value: $ -r Description Of'WOrk= (as calculated per the Building Valuation Data sheet) Plan Review (due at time of submittal): $ Sq. Ft./L.Ft added: Squares (9, BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. C/RLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REI PRINT NAME: c✓ c,$`~' l4',ej o„~ SIGNATURE: of (OWNER) (CONTRATOR) Date: CI.F," d0' Bldg Valuation: