Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3705 Upham Street
4 r City of Wheat Ridge V- r Residential Roofing PERMIT - 201704681 PERMIT NO: 201704681 ISSUED: 07/24/2017 JOB ADDRESS: 3705 Upham ST EXPIRES: 07/24/2018 JOB DESCRIPTION: Residential Re-roof to install OWENS CORNING OAKRIDGE asphalt shingles with 21 SQ 6/12 PITCH *** CONTACTS *** OWNER (720)369-4134 GILMORE DEREK SUB (303)646-9300 Dan Elliott 022311 Assured Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT*: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,000.00 FEES Total Valuation 0.00 Use Tax 147.00 C' Permit Fee 156.75 --- — .. ** TOTAL ** 303.75 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge w � Residential Roofing PERMIT - 201704681 PERMIT NO: 201704681 ISSUED: 07/24/2017 JOB ADDRESS: 3705 Upham ST EXPIRES: 07/24/2018 JOB DESCRIPTION: Residential Re -roof to install OWENS CORNING OAKRIDGE asphalt shingles with 21 SQ 6/12 PITCH I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be rto d and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Z ignature o�4 OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermitfee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Divis 6. The i su or grantin&44"ermit sliall not be construed to be a permit for, or an approval of, any violation of any provision of any applic ordi g ation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Jan Schultz From: no-reply@ci.wheatridge.co.us Sent: Saturday, July 15, 2017 3:51 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number 3705 Upham St ✓'/ Derek Gilmore 720-369-4134 z1v 4V 711,2117 Property Owner Email Contact@assuredroofing.com Address $�_� j Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Assured Roofing Contractor's License 022311 Number (for the City of Wheat Ridge) Contractor Phone 3036469300 Number Contractor Email Address Contact@assuredroofing.com Retype Contractor Email Contact@assuredroofing.com Address DESCRIPTION OF WORK Are you re -decking the roof? Description of Roofing Material Select Type of Material: If "Other" is selected above, describe here: No Owens Corning Oakridge Asphalt Field not completed. How many squares of the 21 material selected above? Does any portion of the property include a flat roof? If yes, how many squares on the flat roof? M Field not completed. TOTAL SQUARES of all 21 roofing material for this project Provide additional detail Re -roof 6/12 pitch here on the description of z work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 7 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Dan Elliott Email not displaying correctly? View it in your browser. 3 18121 E. Hampden Ave. C-112 Aurora, CO 80013 (0)303-646-9300(F)303-646-0034 Web: WWW.Assuredroofing.com Email: Contact@AssuredRoofino.com Homeowner's Name:_1 Irf �� RC1 C- Home Phone: Address: ln)4 ATO:: D�e�l Phone: r , -0a�33 Email & Fax: S�� l� W • c.r, c CInsurance:T`�L Decking Sheets : ' Torch Down ` 1 Ice & Water _9/ -. 0 C6 q <<- � VX 40 `'� Roof Style:ot,W1?n)5 rbat�4. Shingle Color: �TP4y.)=A0 Base Sheet: I -T j2e—n c - z �- br�.r 1Lz9ro L, Tear Off: .a i , © Valley Type: Ridge Type: Roof Stack/Size: LACE P(-,- Vents/Size: Gutters:-.- 4pe-6cl Art 1 /4� ( c A v 0-70, 9 Pitch: -(�; / L -L Drip Edge: 4 L L Gutter Color: 10-4'T'T'A- Insurance replacement and repair: Assured Roofing Inc. agrees to work with homeowners insurance company for the replacements and repair for all trades ( roof, gutters, siding, paint, windows etc..) deemed damaged per insurance loss. Assured Roofing Inc will do work on homeowners company's estimate of the replacements cost value (RCV), and homeowners deductable stated on the insurance loss statement, Homeowner agrees to give a copy of their insurance loss statement and authorizes to have Assured Roofing Inc work with homeowners insurance company. Homeowner agrees to have Assured Roofing Inc. to do the work their insurance pays for. Homeowner agrees to pay Assured Roofing Inc. total cost of replacements or repairs (RCV) as deemed by homeowners insurance company, plus deductable, insurance paid supplements,overhead and profit, and any damaged decking not covered by insurance company. Insurance replacement cost value homeowners initials:r Assured Roofing Inc. hereby purpose to furnish labor and materials completed in accordance with contract provisions and specifications for the sum total of: __. When accepted, this becomes a contract subject to all terms, condidtions and exclusions, and can be withdrawn from the company if not signed within (30) days of receipt. Buyers right to cancel: If for any reason authorizing party decides to terminate contract, they may do so within three (3) business days from the date the agreement is signed. Notice to cancel must be in writing and postmarked no later then the (3rd) business day from the date of the contracts execution. I/Owner have read both sides of this contract and do understand all terms, conditions and exclusions within the contract, and agress thal all details of this contract are satisfactory. I further understand and agree that this contract represents the entire agreement between I/Owner and Assured Roofing Inc and agree that any changes or alterations to this contract must be in writing and fully executed 04 both parties. I Accepte by I/ Owner; i< �'-�"'� J� ��1 �'�K - Sales Representive: Date: i f i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 3 -7C _t- tJ o laam S,t- Permit Number: o t`7 0 N 91 1 ❑ No one available for inspection: Time q =3g`"7PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: tv./73k-7 Inspector: "ib DO NOT REMOVE THIS NOTICE R i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 inspection line '(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 9 V q - P-,,, Job Address: "3 -7 o S- Up h,. 5 -- Permit Number: '�) e 1-7 v L/ 4P g i AJ , / DI j A d {- /' ?- 'F --O I /1 Li r 4 � n ❑ No one available for inspection: Time �= SS- qM PM Re -Inspection required: & No When corrections have been made, call for re -inspection at 303 -234 - Date: e ? o I-? Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 n 1.- /1`1 ' J Job Address: -3-7 a s U ;r� ha Al S?i Permit Number: -;�- C 1 7 C' C4 to % 1 / 1 ' � - l 1C" � D f- IN C� ✓� lam) IrF' C.� c' 1 ❑ No one available for inspection: Time (7,7) - y 151 AM/(9) Re -Inspection required: Yes S When corrections have been made, call for re -inspection at 303-234- Date:- 1 i S Inspector: -1--D DO NOT REMOVE THIS NOTICE ,.�?rV, Citww.y of AMAM)WLJNjTYhDrevf aLoPMENT # 11111111 11111111 i Plan1permit # "? am )"JIM Address. 13 S I ArchitectfEnoirteer" E-mail: Phone.* Sub Contractors: Electrical:Plumbing: Mechanical: W.R. City License # W.R. City License # WR City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRA NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc,) RESIDENTIAL ACCESSORY •i (Garage, t,. .. deck, .. MECHANICAL 7. !Y • A REPAIR 11M i• REPLACEMENT i*.LUMBING d. M1 4M * REPAIR a '. •r yM or REPLACMENT ELECTRICAL SYSTEMIAPPLIANCE REPAIR or REPLACEMENT alay- I i r& -s a-5 an-� was l�n� s 1�c��1`22 Sq. FULF Btu's Gallons City of COMMUNI'T-v Dr-VFL0PTEN, d le4Building & Inspection Services Division to T FOR OFFICE USE ONLY Prn/Pe rt S t , 29 Ave,, W heat Kjage, W uv;53 Plan Review se: Office: 303-235-2355 * Fax: 303-237-8929 Inspection Lire; 393-234-5933 Building +er lit Application Pleas's cOmPlete all highlighted areas on bath sides of this 1 . InOOMP100 Ppii tions rday not be Processed. Property Address.- Y7015. Eroperty Owner (please print): Phone: " Property Owner Email". ov\C y"I , C",Yn(-,'5. corn Address. �; a "S Vg City, State, i .,C, Arcitrtect/Enotn E-mail.- Phone: Contractor: ex ,lc Contractors City Ucense, M Phone: . � . Contractor Emall Address:k0ex Co Sub Contract Electrical, Plumbing: Mechanical: WR City License # W.R: City License # WR City License # Cather City Licensed Sub; Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form amount sof Materials to be used, etc. Sq. FULF IIIBtu's Gallons Amps Squares tither FOR OFFICE USE ONLY City of Mete: Wh6at le tarr ttComm T prance rte' Building & inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 plan Review Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building ar it Application * * please complete all highlighted areas on both sides of this fora. Incomplete applications may not be processed. Property Address Property Owner (please prat): �"horte: Property Owner Email.* Mailing Address. (if different than property address) Address: ArchiteottEngin r E-mail.* Phone Contractor: Contractors City License M phone, Contractor E-mail dress: Soh Contractors: Electrical. Plumbing: Mechanical: W.R. City License # W.R. City License # W.k City License Other City Licensed uta. Other City Licensed Sub: City License # City License Complete all information, on BOTH sides of this for w w a arr s r •t, ** # rF m a #. ° # # .. • # #':^ « m:.:.<a a �...# #.....# #. #Pr. # ..#. #... # # amount of materials to be used, etc.) 4ri-*c-lyAmps car+Other Co UNITY IDE VELOP M[ESRT DEPART NT Building Permit Number: BUILDING INSPECTION LII - 303-234-5933 Date, 0 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) ORP, APPU"TION --- -------- Property Owner: 1 10 J rtbjert;6' Property Address: 3705 k4thom 6T, Phone :,M �5 74'- 75 t',3 Contractor License No,: &1q,1117 Company: Zm a e*oAmerawbone3o3 o� 3BY OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREFTNIENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, casements orrestrictions ofrecord; that all measurements shown, mid allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicable he Ridge Ordinances, for work under this permit. (OWNER)(CONTRACTOR): SIGNED DAT41 #5 DESCRIPTION:kP,qhxde old FPEP-Inet' Ot- '�eflite �z Construction Value: $ Pennit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ r& a n e w 15o omp Service, -Tilshrtl an evtO-fol- e4 scfs"P PamP ;n lite a,;srL,1.5)Ve'c, SIC: SqXt.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof- Stories: Residential Units: Electrical License No: OWN7 Plumbing License No: Mechanical License No: Company: age 0e, a6e ew, Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This pennit was issued in accordance with the provisions set forth in Your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a now permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans andspecifications and any suspension orabandonmenthas not exceeded one()) year. If changes have been or ifs ension or abandonment exceeds one (1) year, full fees shall be paid for a new permit, (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem, (5) Contractor shall notify the Building Inspector twenty-four(24)hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job, (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of any violation of the provisions of the building codes or any other ordinance, law, rate or regulation, lmmwmm�� www.jebelearicinc.com - jobelectricincCoaoLcom IMPULA10r] LIM. I Building Permit Application Property Address.. /-/-- . ° €L Sq. FULF Stu's Gallons Amps Squares Other COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 15783 BUILDING INSPECTION LINE -(303-234-5933) Date : 7/1/2003 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner. LOUISE CARLIN Property Address : 3705 UPHAM ST Phone : Contractor License No. : 21677 Company : GUNNISON ENTERPRISES, INC Phone :(303) 332-7208 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback dislances proposed by this permit application are accurale, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all easurements shown, and allegations made are accurate; that I have read and agree to bi e by all conditions printed on this application, and that I assume full responsibility r ompliance with the Wheal Ridge ild! g Code (U.B.CJ and all other applicable Wheat i e ordinances, for work under this p r' (OWNER)(CONTRACTOR)SIGNED DATE7 G Description : REMOVE ROOFING, REDECK. NEW SIDING, 10 WINDOWS AND NEW EXTERIOR DOORS(2) BUILDING DEPARTMENT USE ONLY Zoning Comments: SIC : Sq. Ft. : Approval : Zoning : Building Commentst' Approval : BG Public Works Comments:' Approval : Occupancy : Walls : Roof : Stories : Residential Units : Construction Value : $20,000.00 Permit Fee : $417.70 Plan Review Fee : $0.00 Use Tax : $240.00 Total $65770 Use : Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company : Expiration Date : Approval : Expiration Date : Approval: Expiration Date : Approval : (1) This permit was issued in accordance with ihe provisions set fotlh in yopur applicalion and is sublect to the laws of the State of Colorado and to the Zoning Regulations and Building Code of W heat Ridge, Coloratlo or any other applicable ordinances of the City. (2) This permit shail expire if (A) ihe work authonzed is not commenced within sixty (60) days from issue date or (B) the builtling authorized is suspended or abandoned for a period of 120 days. (3) If ihis permit expires, a new permit may be acquiretl For a(ee of one-half the amount normally required, pmvided no changes have been or will be made in the original plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceetls one (1) year, full tees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural Flow of water causing a drainage probtem. (5) Contractor shall notify lhe Building Inspector hvenry-four (24) hours in advance for all inspections and shall receive written appmval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the appmval of drawings and specifications shall not be conslrued to be a permit for, nor an approval of, any violation of the prohe building codes or any other ordinance, law, rule or regulation. Chief Building I pector Please sign Terms and Conditions on reverse side of page. COMMtiNITY DEVELOPMENT DEPARTMENT Building Pemut Number: w„Et c' ' P BLILDII~G INSPECTION LI1VE - 303-234-5933 Date: ^ ` ~ CITY OF WHEAT RIDGE " 7500 WEST 29TH AVENliE \~VHEAT RIDGE, CO 80215 - (303-235-2855)~r ~~r ~~c oa Ao° AP~.~IFl.r`f i3s]9 v 1~7 Property Owner: L--b~~r~c'f_~ GAg'Lf d Property Address: j JOS Phone : Contraccor License No.: ,y/ o-y 7 conipanr: C, v.d,✓/ 01i'NER/CONTMCTOR SIGNAR'RE OF CND£RSTA9DISG AND AGREEMENT 1 hercby ttnify that thc sctback distanas proposcd by this pcrmit application arc acwrat<, and do not cfolax applicablc ordinancu, rula or regulanons of the City of H'hwt Ridge of m,'cnanu, eascnxnts or ratrictions o(rttord; that all messuttmcnls shown, and allcgation5 rrude are accunu; that I have rpd and agce to abfdc by all conditions pnnted on this applicalion and that I assumc fuil raponsibiliry for c liancc with thc Whcal Ridgc Bwlding Code (UB.C) and all othcr apph<ablc idgc Ordinantts, for work undcr inis pcm,;t (OtiTERxCONTMCTOR)-. SIGNED Phone: 31 3~Z' 7zoi Construction Value S 24"a~ Permit Fee:$ Plan Review Fee:S Use Tax:$ Total:$ (OV.'tiERMCO`.TAACfORJ-.PRI!JfEDly, /J~IML DATE3 uESCUIrTIo;a: /~l~(~ ~~%WIND0~1S' i ~ZU~ i~K-ta~- C)oQIZS BUILDIIG DEPARTD1ENT LSE ONLY SIC: Sq.Ft.: 20NING COMMlNTS: Approval: Zoning: BUILDING COMMENTS: Approval: h'1' PUDLIC WORI(3 COMM[NT3: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical Licensc No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expintion Date: Approval: APProval: ApprovaP (I) 7biy ycrmit wss icsud m accordaMe wiN tAs pnav+sions sa fML in wur applicnion and is subjm b Nc uw's of dle Su¢ of Colondo md m th< Znnmg Rcgulaliom and Building Codcs of N'ho, RidBe. Cobndo or an) mhcr applicabk ordinanccs of 'h< Cin. (?j Thrs pertnil shall expirt iflA) thc work auJwrized u~ commrnced witAin sury dn (rom issue datc or (B) thc building .wfiorizcd is suspended or abandomd fa a pawd of 120 days. 13) If this permit enD~~. a Mw ycrmit maY be acGuirtd far a ftt of oM-hilf ibe amoum nortnally rW uircd. Provided`h thanha ~bccn frsw JLL~`swn w in tM anprol VW.T +^d syxificwons aod +ny susycnsim aaba°d°"mrn, hu m ucecded one (l) yw. B~ ay,,,dO,mcvt o<aaa ons (l) rear. tu0 ires sA.tl be vaid f« . oew vaemL 14) No work of anY manMr sWU De done thu.vill clwee ths mmnl fiow of "m <ausiag a Mi-gc pobkm. . _ (5) Cwmcar sha0 wwfY ~bc BuiWinY in+pecmr roearY-four (21) hours in W vu~cs fw dl in+pn'rims ud s6a11 raeiw wnnm aFVroval on msyaoon cud nd«s wweodi^g "'im successn<vhaaam orais joe. ~.-v ot. y~ ~pVaon of the (6) 7M issuaace of a pmnil a ~Fc +DW~val of dnwiogs and syecifxaums shdl m be cauwcd a be a pcm~ii fa, mr an WV y• pmvisiau of t6< buildine codn a any ahv wdinance, la.v. ruk or regu6uon. Chief Building Inspector FROM : COLORRDO WINDOW FAX N0. 23 7/8 3T142 SH OBS ` 28 28 323/4 SH `32314 SH GRIDS GRIDS '~~K PO~'G 28 32 3l4-,,y SH GRIDS ~~48 28 5~1/2 SH 53112,, SH GRIDS GRIDS br~ b~ \281/4 _ 15 4 'W;TGRIDS , cNr ~,asf~ SS GRIDS \593/4 53 \ SS GRIDS \81 1/2 5 2 SS GRIDS F~L L, Y\ cl o W s -f S'F~k rS ~-0 6' ~3 `1 ha Y.-, S-l- , Sul. 01 2003 11:32RM P2 ® City of Wheat Ridge �X Residential Roofing PERMIT - 201704681 PERMIT NO: 201704681 ISSUED: 07/24/2017 JOB ADDRESS: 3705 Upham ST JOB DESCRIPTION: Residential Re -roof to install OWENS CORNING OAKRIDGE/24/2018 asphalt shingles with 21 SQ 6/12 PITCH *** CONTACTS *** OWNER (720)369-4134 GILMORE DEREK SUB (303)646-9300 Dan Elliott 022311 Assured Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISIONCODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: UA / Unassigned 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,000.00 Total Valuation FEES 0.00 Use Tax 147.00 Permit Fee TOTAL 156.75 ** ** 303.75 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. 3 5 1-K ' INSPECTIONONLINE POkidll: rlttp://www.cl.wheatliuge.CO.us,lr75Nec/1nn INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. **RPnnPst nn inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Date Inspector Comments Foundation Inspections Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Inspector Comments UndergroundlSlab Inspections Date Initials Electrical Sewer Service Plumbing Do Not Cover Under round or Below/ln-Slab Work Prior To Approval Of The Above Ins Date Inspector Comments Rough Inspections Initials Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric " Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Date Inspector Final Inspections Initials Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Comments ons Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Perrnitted Until A Certificate of Occupancy Is Issued �w r I and Frt rn The Weather