Loading...
HomeMy WebLinkAbout3701 Teller Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: X1"3 F,',� I F1ec Job Address: '3'70( 1-e 1 ie v 9, Permit Number: ")c i g o;L V 7 Ke ! eek5 e A,1, 4�;- ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes Vol When corrections have been made, schedule for re -inspection online at: http✓/www.ci. wheatridge.co. uslinspection j, Date: �'i` l� Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: k`0-5 f7.'^A l F l eJyi-W Job Address: T)01 T-dey 51. Permit Number: ' )ol R Noy -7 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date: Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge I law AMF Residential Solar PERMIT - 201902047 PERMIT NO: 201902047 ISSUED: 10/01/2019 JOB ADDRESS: 3701 Teller St EXPIRES: 09/30/2020 JOB DESCRIPTION: Roof -mount, flush -mount, grid -tied 3.46 kw solar PV installation; 11 panels, no structural required *** CONTACTS *** OWNER (303)418-1513 PROKOP TERESA L SUB (303)577-9628 Andy Nyman 070159 Sunrun Installation Srvs. Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,479.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am tl�e legal owner or have been authorized Y.gal owner of the property and am authorized to obtain this permit an erform the work described and approved in conjunction with nct. I further attest that I am legally authorized to include all a titie amed within this document as parties to the work to be ed andj�,, & all w rk be performe is disclosed in this docu n nd/or/its' accompanying approved plans and specifications. 1 llqldW� 1 �ignature of 'OWNER lop- (CONTRACTOR (Circle one) ( Date 1. This permit was issued'bawd-arr the information provided in the permit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicAble code or anyrdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of" W heat jidgc COMMUNITY DEVELO MENi Building & Inspection Services 7500 W. 291 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: per itsO-ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # j �) I/N V" Plan Review Fe j�,O) Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): AAOkK Phone: /_ _ y19 15813 Property Owner Email: Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor Name: _! cZ 20/ City of Wheat Ridge License #: J7. -3602_- Phone: Contractor E-mail Address: CCt-Oa V . ('£RM 6_)A -t For Plan Review Questions & Comments (please print): CONTACT NAME (please print): *D iN4k)Phone: �2�'j7�ZUCIGI CONTACT EMAIL(p/ease print): 4iDae4j , A),,,* ,-' le- 6dNt Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. [-]COMMERCIAL W RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Sq. FULF BTUs 3 Z -l6 NO e✓ Gallons Amps Squares For Solar:' 1 f ! KW_# of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: _ Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE. (OWNE (CONTRACTOR) or(r(UTHORIZ D REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: G! t Printed Name 14Al6 ✓iYV-t i ZONING COMMMENTS: Reviewer: B;ewer: PARTMENT COMMENTS: R PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: "• 61 i 1 1 Design (mm) Mechanical Parameters Operating Parameters Operational Temperature: -40C -+85C Power Output Tolerance:0 ^+5 W Voc and Isc Tolerance: ±3% Maximum System Voltage: DC150GV (IEC) Maximum Series Fuse Rating: 20A Nominal Operating Cell Temperature: 45±2 C Safety (lass: pass II Electrical Characteristics Model Number Cell Odentation: 120 (6x20) Telerana: Test uncertainty LR6-60HPH-315M L�nmh'�2mm wmm ttmm Junction Box: IP67,three diodes Il*t ±1- ImmPlm,,o,,:timm Pod- tI_ Output Cable: 4mm', 300mm in length STC NOCT Glass: 3.2mm coated tempered glass 1�-2 +jai I Weight l9 kg q'Kr 305 225.9 310 229.6 315 233.4 Dimension:1672x991x40mm nn rPaclog ng. 26pa per pallet 3 156pcs per 20'GP 40.6 37.9 676pcsper 4D'HC Operational Temperature: -40C -+85C Power Output Tolerance:0 ^+5 W Voc and Isc Tolerance: ±3% Maximum System Voltage: DC150GV (IEC) Maximum Series Fuse Rating: 20A Nominal Operating Cell Temperature: 45±2 C Safety (lass: pass II Electrical Characteristics Model Number LR6-60HPH-300M LR6-60HPH-305M LR6-60HPH-310M Test uncertainty LR6-60HPH-315M for Pmax: ±3% LR6-60HPH-320M Testing Condition STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax/W) 300 222.2 305 225.9 310 229.6 315 233.4 320 237.1 Open Circuit Voltage (Voc/V) 39.8 37.1 40.1 37.4 40.3 ! 37.7 40.6 37.9 ---.-- 40.9 ! ------ 38.2 Short Circuit Current (Isc/A) 9.70 7.82 9.78 7.88 9.86 7.94 9.94 8.01 10.02 8.08 Voltage at Maximum Power (Vmp/V) 32.9 30.4 33.1 30.6 33.3 30.8 33.7 31.1 33.9 31.3 Current at Maximum Power (Imp/A) 9.13 7.32 9.21 7.38 9.30 7.46 9.36 7.50 9.43 7.56 Module Efficiency(%) 18.1 18.4 18.7 19.0 19.3 STC (Standard Testing Conditions): Irradiance 1000W/m2, Cell Temperature 251C, Spectra at AM1.5 NOCT (Nominal Operating Cell Temperature): Irradiance 80OW/m2, Ambient Temperature 20 C, Spectra at AM 1.5, Wind at 1m/S Ratings ( STC Temperature Coefficient of Isc +0.057%/C LoadingTemperature Mechanical Front Side Maximum Static Loading 5400Pa Temperature Coefficient of Voc -0.286%/C Rear Side Maximum Static Loading 24001'a Temperature Coefficient of Pmax -0.370%/ C Hailstone Test 25mm Hailstone at the speed of 23m/s Current -Voltage Curve (LR6-60HPH-310M) Power -Voltage Curve (LR6-60HPH-310M) Current -Voltage Curve (LR6-60HPH-310M) W, 3 6 F - WI Temp=25°C - CeII Temp- 15 V 4 - CeIl Temp=45°C - Cell Temp=55°C 2 --- Cell Temp -MT CeII T,m =75' 10 20 Vohage M ■ LONGI Solar 400 Cd ee V.2M aso-m,a.,mawm -bxnm.a.4aow10 -rKwna u.eI400wrmr 250 -.,e xoamaxmrp+ 200 a 150 100 so ` 0 20 30 Vohage M 12 10 8 3 6 u 4 2 0 voltage M IY of Ridge 9anghaL pivisionRoom 201, Building 8, Sandhlll Plaza, lane 2290, Zuchongzhi Road, Pudong District, i, 201203 Tel: +86-21-61047332 Fax: +86-21-61047377 E mail: module@longi-siIicon.com Facebook www.facebook.com/LONG! Solar Note: Due to continuous technical innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONG! Solar have the sole right to make such modification at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make it a consisting and binding part of lawful documentation duly signed by both parties. 201901/5 Complete System and Product Certifications Positive power tolerance (0 —+5W) guaranteed IEC 61215,IEC61730 ISO 9001:2008:150 Quality Management System High module conversion efficiency (up to 19.3%) ISO 14001:2004: ISO Environment Management System Slower power degradation enabled by Low LID Mono PERC technology: first year <2%, T562941: Guideline for module design qualification and type approval 0.55% year 2-25 OHSAS 18001: 2007 Occupational Health and Safety Solid PID resistance ensured by solar cell process optimization and careful module BOM selection Adaptable to harsh environment: passed rigorous salt mist and ammonia tests Specifications subject to technical changes and tests. LONGi Solar Outstanding low light performance average relative efficiency 97.5% or better at 20OW/m2 reserves the right of interpretation. Reduced resistive loss with lower operating current Higher energy yield with lower operating temperature O. Reduced hot spot risk with optimized electrical design and lower opera curren&q � c roQ.� aey�o ���' Solar Room 201, Building 8, Sand: + Plaza, Lane 377 Z E-mail:o Road, Pudong District, Shang 1 Tel: +86-21-61047332 Fax: +86-21-61047377 mail: module@longi-silicon.com Facebook: www.facebook.com/LONGI Solar Note: Due to continuous technical Innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONG! Solar have the sole o ke such modification at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make It a consisting and binding part of lawful documentation duly signed by both parties. 20190115 Sin Phase Inverter WitRle HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER OUTPUT SEXXXXH-XXXXXBXX4 Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 I 10000 11400 @ 240V VA Maximum DC Power @208V - 5100 3300 @ 208V 15500 5000 @ 208V Transformer -less, Ungrounded Yes 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 10.5 13.5 16.5 20 3300 @ 208V 30.5 5000 @ 208V Maximum Input Current @208Vm - 9 10000 @ 208V - AC Output Voltage Min. -Nom. -Max ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) Ground -Fault Isolation Detection 600ku Sensitivity Maximum Inverter Efficiency 99 99.2 i % AC Output Voltage Min. -Nom. -Max 99 ✓ 99 @0 240V 98.5 @ 208V ✓ _ < 2.5 ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.500 i Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output16 24 - 48.5 A Current @208V j Power Factor 1, adjustable -0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 1 - 7750 - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voftage 380 400 Vdc Maximum Input Current @240\61) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208Vm - 9 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ku Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @0 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W in For other regional settings please contact SolarEdge support 0 A higher current source may be used; the inverter will limit its input current to the values stated City of Wheof Ridge Building Division N Single Phase Inverter Wit HD -Wave Technology for North America SE3000H-US SE380OH-US SESOOOH-US SE6000H-US SE760OH-US SE1000OH-US SE1140OH-US ADDITIONAL Supported Communication Interfaces I RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 OptionalO1 Inverter Commissioning with the SetApp mobile application using built-in Wi-F station for local connection Rapid Shutdown -NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL16998, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size /AWG Range 3/4' minimum / 14-6 AWG 3/4' minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4' minimum / 1-2 strings / 14-6 AWG 3/4' minimum / 1-3 strings / 14-0 AWG Dimensions with Safety Switch (WcWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17-6 Ib / kg Nesse < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60t4n Protection Rating NEMA 4X (Inverter with Safety Switch) w Revenue grade inverter P/N: SEmotH-US000BNC4 w Full power up to at least 50'C / 122'F; for power de -rating information refer to: https;/ www.solaredge.com/sites/defauk lies/se-temperaturederating-mte-n&pdf ® SWr[dg@ Tochnologl@§, In€. AN dghts reserved. SOIAR1DGL the SWarEdg@ foga, OPnMIXED CY SOLAREOGE are trademark§ or regi§tared trad@marks of Solarldg@ T@€hnologfe§, Int AN oth@r trademarks m@minted harem ate trkkmerk§ of their resPa€ va owner§. Gate: i/201V40t/ENG NAM. SuBjett to €hang@ without nod€@: O% rOatR�d90 �J RoHS so I a r' 9 • :a SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P370 / P400 / P405 P300 P320 P370 P400 P405 (for higher -power (for 60 -cell mod- (for high-power (for 72 & 96 -cell (for thin film 60 and 7Z -cell ules) 60 -cell modules) modules) modules) modules) INPUT Rated Input DC Power{'i............ 300 320 370 400 405 W Absolute Maximum Input Voltage ....... ...... ....... . ,(Voc at lowest temperature) 48 60 80 125 Vdc MPPT Operatin& Range ...._....... 8-48 8 - 60 8- 80 12.5-10S Vdc Maximum Short Circ it Current Slsc) .......................................... 10 11 10.1 ...................I....................:.........,........................I.............. Adc Maximum DC Input Current i?:? 13.75 12.63 ...........,.. Adc Maximum Efficiency ...................... ..............1......... 99.5 .......................................................... Wei hted Efficien ..............�Y........................ . ...................................... 98II.8 ................. """"""" % Overvoltage Category ..., OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current ........ ............................. 15 .•.................................................................... Maximum0ut utVoltage . 60 � � � ����. ......��'� 85 �`�"'�c""' Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power O timizer 1 =Vd STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6 3 Safety ................................... ................ ty), UL1741 Yes INSTALLATION SPECIFICATIONS Maximum Allowed System VoitW 1000 ................................................... Vdc patible i Comnverters All SolarEdge Sin4le Phase and Three Phase.inverters ..... ...................................... .. .............. Dimensions (W x L x H) 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128x152x35/ 128x152x50/ m mm/in ....... ............................................................... .... 5x5.97x1,37... x5.9 x1. 7•,..96 Wei ht(includin cables) ...,..6.............6...................,..,,..................,....,...................,.... 630/1.4 750 1.7 ::;5 .., .....,.....�.......... .845./1:9...,.. ..,�COb.... Input Connector p MC4 Compatible MC4 / MC4 Compatible Amphenol AH4 .. ....................... . ................... Double Insulated; .............. Output Wire Type / Connector Double Insulated; MC4 Compatible MC4/ Double Insulated; MC4 Compatible Amphenol AH4 .... ........ I ...... I ...... ...., Out ut Wire LenBt..h ..P ...............,..,...,..,.....,..........,,........,.0.95 /3:Q.,..,.........................,...<.........,.,1.2/3:9,......................,..... ^?........ Operating Temperature Ranke„ , ........... -40 - +185 ............................................. ... *C/'F Protection Ratin IP68 NEMA6P Relative Humidity 0 -100 Isl Rated STC power of the module. Module of up to +5% power tolerance allowed. _ PV SYSTEM DESIGN USING A SOLAREDGE INVERTER10l3l SINGLE PHASE HD -WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 460V Minimum String Length 8 „(Power Optimizersl...... .<... ............ ..... Maximum String Length 25 (Power Optimizers)..................................................... Maximum Power per String 5700 (6000 with 5250 .....S......E760-U5)....... ................ Parallel Strings of Different Lengths Yes or Orientations c21 For detailed string sizing information refer to: httpl/www.solaredge.mm/apes/default/flies/string_sizing_no.pdf (r) It is not allowed to mhc P405 with P300/P370/1,400/1'600/1'700 in one string. solar -.. m. SolarEdge Power Optimize Module Add -On For North Ameri P300 / P320 / P370 / P400 / P405 PV power optimization at the module -level — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt - Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety USA.CANADA-GERMANY. ITALY -FRANCE °JAPAN CHINA -AUSTRALIA -THE NETHER LANDS•UK-ISRAEL,TURKEY -SOUTH AFRICA-BULGARIA•INDIA www.solaredge.us DocuSign Envelope ID: 13BBF760-F2D7-448C-80C1-67B75232C88A a,sunrun' September 26, 2019 Subject: Structural Certification for Proposed Residential Solar Installation. Job Number: 501R-701PROK; Plan Set: Rev Al, Dated 9/17/2019 Client: Mark Prokop Address: 3701 Teller St, Wheat Ridge, CO, 80033 Attn: To Whom It May Concern A field observation was performed to document the existing framing of the above mentioned address. From the field observation, the existing roof structure was observed as Composition Shingle roofing over roof plywood supported by 2x6 Rafter @ 24" OC. The roof is sloped at approximately 27 degrees and has a max rafter span of 12'8" between supports. Design Criteria: • 2012 International Building Code Basic Wind Speed Vult = 135 mph (Vasd = 105 mph), Exposure C Ground Snow Load = 30 psf After review of the field observation report, the existing roof framing supporting the proposed solar panel layout has been determined to meet or exceed the requirements of the applicable building code referenced above. Therefore, no structural upgrades are required. �+" ..•�,�A, DocuSigned by: NM .••..of (� f 01 EF89FE560A443... i S 9349 9/26/2019 Gi1Y of �i VXd Cie ssr0NA".ti� pwision dd�n9 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0 3 DocuSign Envelope ID: 13BBF760-F2D7-448C-80C1-67B75232C88A Structural Calculations for the Mark Prokop Residence PV Installation Date: 9/26/2019 Job Address: 3701 Teller St Wheat Ridge, CO, 80033 Job Number: 501R-701PROK Scope of Work These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 House Geometry, Live Loads, Snow Load, Wind Loading, & Dead Loading 3 Roof (2) Dead Loading, Roof (1) Framing Check 4 Roof (1) Framing Check cont., Roof (2) Framing Check 5 Roof (2) Framing Check cont., Rafter Attachment Check, Seismic Check, & Scope of Work Engineering Calculations Summary Code: 2012 International Building Code ASCE 7-10 Snow Load: S = 30 psf Live Load: LL = 20 psf Wind: Wind Speed Ult. (V) = 135 mph PV Dead Load: DPV = 3.0 psf Exp. = C DocuSigned C �n, by: Cl �9n Ot EFB9FE560A443... 9/26/2019 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 ow of WheQt g�d9® S�p:N 6 �n9� Oil DocuSign Envelope ID: 13BBF760-F2D7-448C-80C1-67B75232C88A a Structrure Geomet Address: 3701 Teller St Wheat Ridge, CO, 80033 2 of 5 Mean Roof Height, h" = 12 ft Eave Height, he = 8 ft Buiding Length, L = 40 ft Building Width, B = 30 ft Module Area = 20 ft2 Roof Pitch, 0 = 27 degrees Live Load: Roof Live Load, Lr = 20 psf Equation 4.8-1 Snow Load: Ground Snow Load, pg = 30 psf Fig. 7-1 Snow Importance Factor, Is = 1.00 Table 1.5-1 Thermal Factor, Ct = 1.1 Table 7-3 Exposure Factor, Ce = 0.9 Table 7-2 Roof Slope Factor, Cs = 1.00 Figure 7-2c Flat Snow Load, Pf = 20.8 psf Equation 7.3-1 Sloped Roof Snow Loads, Ps = 20.8 psf Equation 7.4-1 Is the width of the roof > 20ft7 Yes Drift Height, hd = 1.44 ft Figure 7-9 Roof slope for a rise of one, S 1.96 City of Unbalanced Width = 5.36 ft Fig 7-5 y = 18 pcf Equation 7.7-1 Unbalanced Snow Load = 39.13 psf Fig 7-5 Wind Load: Whit {tidy® Basic Wind Speed (3s -gust), V = 135.0 mph Figure 26.5-1A Building Occupancy Category = 2 Table 1.5-1 Wind Importance Factor, IW = 1.00 Table 1.5-2 Exposure Category = C Sec 26.7.3 Topographic Factor, Kzr = 1.00 Equation 26.8-1 Velocity Pressure, qh = 33.71 Equation 30.4-1 Edge Zone, a = 3.00 ft Figure 30.5-1 Uplift (0.6W) Zone 1 (psf) Zone 2 (psfl Zone 3 (psf) Composition Shingle 3.0 psf GCp = -0.84 -1.55 -2.43 Table 30.4-2 2.0 P30.4 = .6 x qh x GCPzone = -16.99 -31.35 -49.05 Equation 30.4-1 1.0 Downward (0.6W) 2.0 PV System, Ppv 3.0 GCp = 0.43 0.43 0.43 Table 30.4-2 City of P30.4 =.6 x qh x GCPzone = 9.60 9.60 9.60 Equation 30.4-1 Whit {tidy® Dead Load:ildin9 pivision Roof (1): Roof Walls - Exterior Composition Shingle 3.0 psf Wood 5.0 sf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x6 Rafter @ 24" OC 1.0 Gypsum 3.0 Misc. (Ceiling, Insulation, etc.) 1.0 Misc. (Insulation, etc.) 2.0 PV System, Ppv 3.0 Total Roof DL= 10.0 psf Total Wall DL= 12.0 psf 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 DocuSign Envelope ID: 13BBF760-F2D7-448C-80C1-67B75232C88A Roof (2): Address: 3701 Teller St Wheat Ridge, CO, 80033 3 of 5 Roof 3.30 ft Walls - Exterior = 2x6 Rafter @ 24" OC Composition Shingle 3.0 psf Wood 5.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x6 Rafter @ 24" OC 1.0 Gypsum 3.0 Misc. (Ceiling, Insulation, etc.) 1.0 Misc. (Insulation, etc.) 2.0 PV System, Pp� 3.0 203 Ib Total Roof DL = 10.0 psf Total Wall DL = 12.0 psf Roof (1) Framing Check: 3.30 ft Roof Framing = 2x6 Rafter @ 24" OC Timber Species = Doug Fir -Larch #2 Max Beam Span = 12.67 ft b = 1.5 in d = 5.50 in Moment of Inertia, Ix = 20.80 in" Section Modulus, Sx = 7.56 in; Bending Stress, Fb = 900 psi Elastic Modulus, Emin = 580000 psi Sheer Stress, F�' = 180 psi CD (Wind) CD (Snow) CLS CM Ct Wood Adjustment Factors: 1.60 1.15 1.15 1.00 1.00 CL CF Cfu Ci Cr 1.00 1.30 1.00 1.00 1.15 PV Tributary Width, Wpv = 3.30 ft PV Tributary Length, Lpv = 4.0 ft PV Tributary Area, At = 13.2 ft2 PV Dead Point Load, PD = Ppv x At = 35 Ib Roof Distributed Load, wDL = 12 plf Load Case: 0.6DL+0.6W (CD = 1.6) Roof Zone = 1 Pup = Pnet x At + 0.6 x PD x COS(0) = 203 Ib Mb(wind-up) = 198 lb -ft Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCI xCr = 2476 psi Mallowable = Sx x Fb' (wind) = 1560 Ib -ft > 198 OK Load Case: DL + 0.6W (CD =1.6) Pdown = Pnet x At + PD x COS(B) = 162 Ib Mb(wind_down) = 743 lb -ft Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XCI xCr = 2476 psi City 01 Mallowable = Sx x Fb' (wind) = 1560 Ib -ft > 743 OK wheat R+d9A Load Case: DL+0.75(0.6W)+0.755 (CD =1.6) Roof Snow Distributed Load, wSL = 42 plf a dingp'vision Psnow = Ps x At = 245 Ib Mb(wind_snow) = 1204 lb -ft Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi xCr = 2476 psi Mallowable = Sx x Fb' (snow) = 1560 Ib -ft > 1204 K 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 DocuSign Envelope ID: 13BBF760-F2D7-448C-80C1-67B75232C88A Load Case: DL + S (CD =1.15) Roof Snow Distributed Load, wSL = Psnow = Ps At = Mb(snow) Fb' (snow) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi xCr = Mallowable = Sx x Fb' (snow) = Roof (2) Framine Check: 42 plf 245 Ib 1101 Ib -ft 1779 psi 1121 Ib -ft > Address: 3701 Teller St Wheat Ridge, CO, 80033 4of5 1101 OK Roof Framing = 2x6 Rafter @ 24" OC Timber Species = Doug Fir -Larch #2 Max Beam Span = 12.67 ft b = 1.50 in d = 5.50 in Moment of Inertia, 6 = 20.80 in Section Modulus, Sx = 7.56 in' Bending Stress, Fb = 900 psi Elastic Modulus, Emin = 580000 psi Sheer Stress, Fv' = 180 psi CD (Wind) CD (Snow) CLS CM Ct Wood Adjustment Factors: 1.60 1.15 1.15 1.00 1.00 CL CF Cfu Ci Cr 1.00 1.30 1.00 1.00 1.15 Roof (2) Framing Check Continued: PV Tributary Width, Wpv = 5.50 ft PV Tributary Length, Lpv = 2.00 ft PV Tributary Area, At = 11.00 ft2 PV Dead Point Load, PD = Ppv x At = 29 Ib Roof Distributed Load, wDL = 12 plf Load Case: 0.6DL + 0.6W (CD =1.6) Roof Zone = 1 Pup = Pnet X At + 0.6 x PD x Cos(B) = 169 Ib Mb(wind_up) = -467 lb -ft Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi XCr = 2476 psi Mallowable = Sx x Fb' (wind) = 1560 Ib -ft > -467 OK Load Case: DL + 0.6W (CD =1.6) Pdown = Pnet x At + PD x cos(e) = 135 Ib Mb(wind_down) = 743 lb -ft Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu XG XC, = 2476 psi COY 01 Mallowable = Sx x Fb' (wind) = 1560 Ib -ft > 743 OK Why {tid9e Load Case: DL + 0.75(0.6W) + 0.75S (CD =1.6) Roof Snow Distributed Load, wSL = 42 plf pliion is Psnow = Ps X At = 204 Ib ding Mb(wind_snow) = 1204 lb -ft Fb' (wind) = Fb XCD XCLS XCM XCt XCL XCF XCfu xCi XCr = 2476 psi Mallowable = Sx x Fb' (snow) = 1560 Ib -ft > 1204 OK 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 DocuSign Envelope ID: 13BBF760-F2D7-448C-80C1-67B75232C88A Address: 3701 Teller St Wheat Ridge, CO, 80033 5of5 Load Case: DL + S ICD =1.151 Roof Snow Distributed Load, wSL = 42 plf Psnow = Ps At = 204 Ib Mb(snow) = 1101 lb -ft Fb' (snow) = Fb XCD XCLs XCM XCt XCL XCF XCfu XCi XCr = 1779 psi Mallowable = Sx x Fb' (snow) = 1121 Ib -ft > 1101 OK Rafter Attachments: 0.6D+0.6W (Zone 2) Puplift = At x Pnet = 393 Ib Connector Uplift Capcity per SnapNRack Test Results = 600 Ib 5/16" Lag Screw Withdraw] Value = 266 Ib/in Lag Screw Penetration = 2.5 in Allowable Capacity with CD = 1064 Ib Seismic Check: > 393 OK Table 11.2A - NDS > 393 OK %increase = (Wtotal + Warray) / Wtotal 22410 *100%-100% = 2.61% ** 21840 **The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. City of Wheat iWO90 ding p' IS10n 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 Existing Dead Load: Solar Dead Load: Aroofexisting = 1200 ft2 Wpanel = 42 Ib Wroofexisting = 8400 lb Numpanel = 11 Awallexisting = 1120 ft2 Wpanel_tot = 462 Ib Wwallexisting = 13440 lb Wbos = 108 lb Wtotal = 21840 lb Warray = 570 lb %increase = (Wtotal + Warray) / Wtotal 22410 *100%-100% = 2.61% ** 21840 **The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. City of Wheat iWO90 ding p' IS10n 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.393.0993 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 3465W DC, 3000W AC • ALL WORK SHALL COMPLY WITH NEC 2017, IBC 2012, MUNICIPAL CODE, AND ALL SOLAR MODULES PV -1.0 COVER SHEET • MODULES: (11) LONGI GREEN ENERGY TECHNOLOGY CO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SE SERVICE ENTRANCE LTD: LR6-60HPH-315M PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV -2.0 SITE PLAN • INVERTER(S): ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV -3.0 LAYOUT (1) SOLAREDGE TECHNOLOGIES: SE3000H-US WITH PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY MP MAIN PANEL PV -4.0 ELECTRICAL REVENUE GRADE METERING GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • RACKING: MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SNR B MOUNT PV -5.0 SIGNAGE SNAPNRACK RL; FLASHTRACK COMP. SEE DETAIL INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.SP SUB -PANEL SNR A MOUNT SD -00708 RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. LC PV LOAD CENTER CHIMNEY Q • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). SM SUNRUN METER ATTIC VENT • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.94 AMPS MODULE SHORT CIRCUIT CURRENT. • 15.53 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). PM 0 FLUSH ATTIC VENT DEDICATED PV METER o PVC PIPE VENT Z .. zi q� CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION INV INVERTER(S) WITH C - METAL PIPE VENT INTEGRATED DC DISCONNECT AND AFCI z; T -VENT U S` AC AC DISCONNECT(S) Z 0 SATELLITE DISH DC DC DISCONNECT(S) FIRE SETBACKS Z • '� 0 CB COMBINER BOX HARDSCAPE Q F_ 7 INTERIOR EQUIPMENT — PL— PROPERTY LINE LE 2 SHOWN AS DASHED SCALE: NTS Approval Notes: sunrun A AMPERE 1)Verify or provide supplemental ground rod or AC ALTERNATING CURRENT rods per 2017 NEC Art. 250.53(A)(2). 2) Natural Gas piping to be bonded s per 2017 NEC AFCI AZIM ARC FAULT CIRCUIT INTERRUPTER AZIMUTH VICINITY MAP Art. 250.104(B). COMP COMPOSITION EC #7080, ME #30603 3)Bond P/V panels to the building Grounding DC DIRECT CURRENT Electrode System per 2017 NEC Art. 690(A). (E) EXISTING EXT EXTERIOR 6040 WEST91ST AVENUE, WESTMINSTER, CO 80031 PHONE 303.577.6527 Arvada FIRM FRAMING FAX 303.577.9629 INT INTERIOR CUSTOMER RESIDENCE: city0f �1C LBW LOAD BEARING WALL MARK PROKOP mCowwuwnvW MAG MAGNETIC 3701 TELLER ST, WHEAT RIDGE, MSP MAIN SERVICE PANEL CO, 80033 APPROVED 4S (N) NEW NTS NOT TO SCALE TEL. 7204181513 Lakeside Reviewed for Code Complianee OC ON CENTER APN #: 26373 PRE -FAB PRE -FABRICATED PROJECT NUMBER: 13701 Teller Street PSF POUNDS PER SQUARE FOOT 501 R-701 PROK wheat Ridge ' `� PV TL PHOTOVOLTAIC DESIGNER: (415) 580-6920 ex3 TRANSFORMERLESS Plans kxamtner Cert TYP TYPICAL V VOLTS MARGARET CAULEY y3Fd niitvol�r�7Ar:ssuanreoJopermifaoppwMoJpb�tf0eri�a•we W WATTS Edgewater °RECO"'P''„1O"""O��o�"""rl�ta�roo•ow�ol.••r�•4to•m SHEET REV NAME DATE COMMENTS o•r •1Ow vrc-w- of der kWd-g war o• o PWCi p ord-4rm. rtnnb wr,www•rooaprkrw•+am�ar�a►a.r•w�lsolw.r COVER SHEET MileHtghstadium aoMnaOnonasa/MtUtYsAOMeotMwlN. REV: Al 9/17/2019 PAGE PV -1.0 (95J 15- ARRAY TRUE MAG PV AREA SITE PLAN - SCALE = 1/8" = 1'-0" SITE PLAN DETAIL - SCALE = 1132" = V-0" PITCH AZIM AZIM (SQFT) ® AR -01 27° 90° 81' 72.2 AR -02 27° 270° 261' 126.3 (E) GATE PL PL „ ... .' (N) ARRAY AR -02 - (N) ARRAY AR -01 (E) DETACHED STRUCTURE ° m rn J � 0_ r PL D1 PL (E) FENCE (E) RESIDENCE sunrun EC #7080, ME #30603 8040 WEST 91ST AVENUE, WESTMINSTER, C080031 PHONE 303.577.8527 FAX 303.577.9829 ROOF PATHWAYS (3' TYP) CUSTOMER RESIDENCE: MARK PROKOP 3701 TELLER ST, WHEAT RIDGE, CO, 80033 TEL. 7204181513 APN #: 26373 PROJECT NUMBER: ow °� 501 R-701 PROK MPSE PM C INV w.000,vxd9e DESIGNER: (415) 580-6920 ex3 MARGARET CAULEY ���dtn9 SHEET SITE PLAN REV: Al 9/17/2019 PAGE PV -2.0 1--1 --- in. 1000r�r_n rnn� eeon onna r_-vo�cno�noon ROOF TYPE MOUNTING DETAIL ROOF HEIGHT ROOF EXPOSURE FRAME MATERIAL FRAME TYPE FRAME SIZE MAX FRAME SPAN OC SPACING ROOF EDGE ZONE MAX PEN SPACING MAX MoD. OVERHANG DESIGN CRITERIA MODULES: AR -01 COMP SHINGLE - RL FLASHTRACK COMP. SEE DETAIL SD -00708 1 STORY ATTIC WOOD 2X6 RAFTERS 2 X 6 12'- 8" 24" 3' - 0" 2'- 0" 0' - 8" LONGI GREEN ENERGY AR -02 COMP SHINGLE - RL FLASHTRACK COMP. SEE DETAIL SD -00708 1 STORY ATTIC WOOD 2X6 RAFTERS 2 X 6 12'- 8" 24" TECHNOLOGY CO LTD: LR6-60H 'H -315M 3'- 0" 2'- 0" 0' - 8" MODULE DIMS: D1 - AR -01 - SCALE: 3/16" = 1'-0" PITCH: 27° 66.26" x 39.21" x 1.38" (36mm) MODULE CLAMPS: AZIM: 90° Portrait: 14.6" - 18.5" 9'-11" Landscape: 5.9" - 9.8" 24'-8" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30P F 3' WIND SPEED: 105 MPH 3 -SEC GUST. LAG SCREWS: 5/16"x4": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF 11'-2" ANY DISCREPANCIES BEFORE PROCEEDING. PENETRATION SPACING: FULLY STAGGERED 6'-6" ROW SPACING: 0.5" BETWEEN ROWS COLUMN SPACING: 11" 0.5" BETWEEN COLUMNS - -- D2 - AR -02 - SCALE: 3/16" = 1'-0" PITCH: 27° sunrun AZIM: 270° }— 3'— 22'-3" 12'-4" �i EC #7080, ME #30603 3' NOTE TO INSTALLER APPLIES LANDSCAPE MODULES (TYP). 6040 WEST 91ST AVENUE, WESTMINSTER, CO 80031 PHONE X303.5 7.9629 7 FAX 303.577.9629 MAX PEN. SPACING = 4'- 0" MAX OVERHANG = l'- 4" CUSTOMER RESIDENCE: MARK PROKOP 3701 TELLER ST, WHEAT RIDGE, CO, 80033 - 8'-10" DoeuSigned by: �a.4.ex�, EA,awn, 01EFB9FE560A443.. TEL. 7204181513 APN #: 26373 PROJECT NUMBER: 501 R-701 PROK 8'-9" 9/26/2019 T-2"�� 12'-4" of o�pQO CIGFyS •` A Bq'•,y ,c3 W heQt R1d9e � �a� q 2I X9349 (��`�, �► �sSf01�AL DESIGNER: (415) 580-6920 ex3 MARGARET CAULEY SHEET LAYOUT 24'-8" REV: Al 9/17/2019 PAGE PV -3.0 SEE SITE PLAN FOR NORTH ARROW CONDUIT SCHEDULE 120/240 VAC CONDUIT CONDUCTOR NEUTRAL GROUND SINGLE PHASE NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER SERVICE 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 METER #: Approval Notes: 1)Verify or provide supplemental ground rod or (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 O XCEL 53 911 804 rods per 2017 NEC Art. 250.53(A)(2). EGC/GEC 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 2) Natural Gas piping to be bonded s per 2017 NEC UTILITY EGC/GEC Art. 250.104(B). GRID EXISTING 3)Bond P/V panels to the building Grounding 1 Electrode System per 2017 NEC Art. 690(A). 125A MAIN CBREAKER 1 (END FED) EXISTING --' '— 125A SOLAREDGE TECHNOLOGIES: MAIN (N) LOCKABLE SE3000H-US WITH REVENUE PANEL (N) DEDICATED BLADE TYPE GRADE METERING FACILITY PV KWH METER AC DISCONNECT 3000 WATT INVERTER JUNCTION BOX PV MODULES LOADS4 4 3 2 OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPH-315M (11) MODULES --- OPTIMIZERS WIRED IN: IF (1) SERIES OF (11) OPTIMIZERS Fncwn 20A PV -GROUND 240V METER SOCKET SQUARE D LOAD RATED DC DISCONNECT BREAKER AT 200A CONTINUOUS DU221RB WITH AFCI, RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END WITH LEVER BYPASS 3R, 30A,2P COMPLIANT P320 OF BUSBAR [MAX 10' FROM 120/240VAC UTILITY METER] [MAX 10' FROM UTILITY METER] [READILY ACCESSIBLE MEANS FOR RAPID SHUT DOWN] CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC NOTES TO INSTALLER: • 11 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. • ADD 20 AMP PV BREAKER TO MAIN PANEL. • • FIELD SPLICE WIRE TO APPROPRIATE SIZE FOR MANUFACTURE TERMINATION SPECIFICATIONS WHEN NEEDED. • WIRE UPSIZE AT TIME OF INSTALLATION IS PERMISSIBLE. MODULE CHARACTERISTICS P320 OPTIMIZER CHARACTERISTICS: LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 48 VDC LR6-60HPH-315M: 315 W MAX INPUT ISC: 11 ADC OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 33.7 V City of SHORT CIRCUIT CURRENT: 9.94 A SYSTEM CHARACTERISTICS - INVERTER 1 Whe0%g`d9e SYSTEM SIZE: 3465 W SYSTEM OPEN CIRCUIT VOLTAGE: 11 V D"j5'Un �isn9 SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 9.12 A SYSTEM SHORT CIRCUIT CURRENT: 15A IWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2017:690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) aWARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): NEC 2017:690.5(C), NEC 2014: 690.5(C), NEC 2011: 690.5(C) aWARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS I ARR I nCATinN- LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) 705.12(D)(4) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): NEC 2017: 705.12(13)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2017:690.31 (G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2017: 690.54, NEC 2014:690.54, NEC 2011: 690.54 3.5" INVERTER 1 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2017: 690.53, NEC 2014:690.53, NEC 2011: 690.53 LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2017: 690.12, NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1 91 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SERVICE SOLAR PANELS ON ROOF INVERTER (EXT) 0111 of AC DISCONNECT "RAPID SHUTDOVy; 3qo v,Ih ENTRANCE AND PV BREAKER DISCONNECT 3701 TELLER ST, WHEAT RIDGE, CO, 800 SNAPNRACK RL FLASHTRACK COMP MOUNTING 5/16" UMBRELLA LAG SCREW MUST EMBED 2-1/2" INTO THE ROOF STRUCTURAL MEMBER/RAFTER 5/16" UMBRELLA LAG SCREV 5/16" STAINLESS STEEL UMBRELLA LAG SCREW 2-1/2" MINIMUM EMBEDMENT FLASHTRACK COMP COMP FLASHING (HATCHED) DETAIL A COMP FLASHING SLIP FLASHING UNDER SHINGLE ABOVE ROOF RAFTER (TYP.) ROOF ATTACHMENTS SHALL ROOF SHEATHING, UNDERLAYMENT, ALWAYS BE EMBEDDED INTO AND ROOFING MATERIAL (TYP.) ROOF RAFTERS OR OTHER STRUCTURAL MEMBERS TRACK COMP 4BRELLA GASKET HADED GRAY) )OF SHEATHING FLASHING SHOULD EXTEND TO END OF SHINGLE COURSE FLASHTRACK COMP REVISION: A 6/19/2017 NEW ITEM GTV COMPLETED INSTALLATION SECTION VIEW FLASH TRACK SHOULD BE ORIENTED NO MORE THAN 3 DEGREES FROM PARALLEL TO RAFTER ROOF DECKING 2-1/2" MIN. EMBEDMENT INTO STRUCTURAL MEMBER City 01 Wheat 01390 COMPLETED INSTALLATION guidln9�N�sion �ll tJ�ll n ���n n Sunrun South LLC DESIGNER: G.McPheeters SCALE: NTS PART NUMBER: DESCRIPTION: V REV / �Y�\\��J� ��V7] 595MARKETSTREET,29THFLOOR•SANFRANCISCO,CA 94105 USA PENETRATION DETAIL, FLASHTRACK COMP A IIS/J) PHONE (415) 580-6900• FAX (415) 5868902 DRAFTER: G.VISCUsO SD -00708 IJ THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY DATE: 6/19/2017 REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE APPROVED BY: G.MCPheeterS WRITTEN CONSENT OF SUNRUN SOUTH U.C. tuPC ■ iu acs Occupancy/Type INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project I Foundation Inspections Date II Comments Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter �- Do Not Pour Concrete Prior To Annraval Of The Ahnva Inanar-finne Underground/Slab Inspections Date Inspector Initials Comments Electrical Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. ._...w, Sewer Serviice Inspections fror one week in adv inspections call 3 inspections call 3 contact the Fire F Floodplain Inspection (if applicable) Plumbing Fire Inspection / Fire Protection Dist, uo not mover unser rouna or tselownn-Slab work Prior To ARroval Of The Above Inspections ector Rough Inspections Date InspComments Initials Wall Sheathing Mid -Roof 3 3d Lath / Wall Tie m Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Insulation Drywall Screw / Nail Final inspections Date a Inspector Initials Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. Inspections fror one week in adv inspections call 3 inspections call 3 contact the Fire F Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist, Final Electrical Final Plumbing Final Mechanical Roof 1 7 Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. 'For low voltage permits - Please be sure that rough inspections are completed frornthe Fire District and electrical low voltage )y the Building Division, "For Inspection Time Window Requests - Please email inVtimerequest c ci.wheat d_ge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: R o f' Job Address: 37a 1 11t, Permit Number: 6 -a Lf 7 ❑ No one available for inspection: Time ' / () AM/PM Re -Inspection required: Yes No *When corrections have been made, call f rare -inspection at 303-234-5933 1 Date:" (� " Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE �(303) Building Inspection Division (303) 234-5933 Inspection line 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M A Job Address: �"1 0 f Permit Number: a.0 1 '7 6 U ❑ No one available for inspection: Time i �'AM/PM Re -Inspection required: Yes No Pry' When corrections have been made, call for reiinspectiofa'at 303-234-5933 Date Inspector: _ DO NOT REMOVE City of Wheat Ridge -+c s a Residential Roofing PERMIT - 201700247 PERMIT NO: 201700247 ISSUED: 02/21/2017 JOB ADDRESS: 3701 Teller ST JOB DESCRIPTION: Reroof 15 sqs with Owens Corning Duration lStorm shingles. /2018 *** CONTACTS *** OWNER (303)421-9893 PROKOP TERESA L SUB (303)295-2220 Tomas Wofram 110052 Core Contractors, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: OAS/ Unassigned *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,200.00 Total Valuation FEES0.00 Use Tax 75.60 Permit Fee 125.05 ** TOTAL ** 200.65 �L ` *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A;4 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€Tos installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner r the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispennrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be per and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior andspecific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. >. The iss an o ranting of a permit hall not be construed to be a permit for, or an approval of, any violation of any provision of any applica le od r any ordinanc or egula ' n of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official () Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of Wheat Ridge Residential Roofing PERMIT - 201700247 PERMIT NO: 201700247 JOB ADDRESS: 3701 Teller ST ISSUED: 02/21/2017 JOB DESCRIPTION: Reroof 15 sqs with Owens Corning Duration lStorm l/2018 shingles. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner r the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispennrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be per and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior andspecific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. >. The iss an o ranting of a permit hall not be construed to be a permit for, or an approval of, any violation of any provision of any applica le od r any ordinanc or egula ' n of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official () Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. 51- INSPECTION RECORD INSPECTION REQUEST LINE: (303) 234-5933 Occupancy/Type Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter uo IVor Four [concrete Prior In Annrnval [It Tha Ahnva Inanarfinna Underground/Slab Inspections Date Inspector Comments Initials Electrical Comments Sewer Service Plumbing uo Not Lover unaerarouna or tseinwim-Sian Wnric Ff Inr _Fn Annrnval Cif Tho Ahnva Incnornfinnc Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Landscaping & Parking / Planning Dept. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building Inspections fror City a# Wheat Ridge one week in ad% 02/21/2017 09.15 ODD inspections call 3 Reroof 15 sqs with 0 inspections call 3 CDD014297 AMOUNT contact the Fire F DpgP 3701 Teller ST 200.65 APDL/PERMIT NO: 201700247 PAYMENT RECEIVED AMOUNT MC / 7357 200.65 RUTH CODE: 07015T TOTAL 200.65 ---------------------------------------- NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. "For Inspection Time Window Requests — Please email insotimereouest(a)ci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather ( itN k.)i w}1rZt lc}c3L� Building & Inspection Services Division 7500 W. 29`° Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 Email permits(ctci.wheatridpe.co.us FOR OFFICE USE ONLY bate: PlanlPermlt # u Plan Review Fee: Building Permit Application ". Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. '** Property Address: 3-701 to llEr 53 W C Property Owner (please print): �V q f �ln � Phone: 1813 Property Owner Email: QA - Mailing Address: (if different than property address) Address: , State, Zip: Architect/Engineer E-mail: Phone: Contractor: Core C,p/!`t c lorS Contractors City License #: H G G 131 Phone: Cao 3) 14 of Q Contractor E-mail Address: Jac -'S@ cc re C4o49 1. (4 Al Sub Contractors: Electrical W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING COMMERCIAL ADDITION ® RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck. etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT El PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) ) ,J �1Ci+t�?(F�� 02 e ><I S'1I qty $41.1)le {/(`T'1 a lJ(�tS (0r, 6f p4t P��u)C ���� re 14. Sq. Ft.11.F Amps Btu's Gallons Squares S Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) /��fflllll O%NNER/CONTRACTORSIGr,AlL.REOF LNDERS'IANDIVG ANI) AGR EE NI FIN I I hereby certify that the setback distances proposed by this permit appllca:ion arc a carate and do not violate applicable ordinances. nlles or regulations ofthe City of wheat Ridge or covenmm, ensentents or restrictions ofrecord; that all meastRements shown and allegations made me accurate. that I have read and agree to abide by all conditions printed nn this application and that I assume full responsibility fbr conifthance with applicable City of llntew Ridge codes and ordinances Ibr work under any pcnntt issued based on this application: that I atn the legal im1wr or lave been authorized by the legal owner of the property to perforin the described u, rk and :nn also authorized by the legal ohne, ref any entity included oil this application to list that entity on tilts 1.pplicanon. 1. the applicam G"Ir this IiAldutg permit application. %%arrant the truthlidness of the information provided on the application CIRCLE 0,VE: (01VtVCR) (".%'TR.ICTOR) r • (;It'THOR/7-ED RCPRESLA7..IT/1 E) q/ (0lI 'L -R) WO.Y7R IC'TOR/ Electronic Signature (first and last name): DATE: a c 1 ZONING COMMMENTS: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer. DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION Building Division Valuation: $ IV INSPECTIOI Inspections will not be made ur Call by 3:00 PM to receive' 1JV J� LJ� - �/JJJ I card is posted on the' building site n the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE '. INSPECTOR ..INITIALS COMMENTS: Footings /Caissons.! Plumbing r; Stemwall / (CEG);Concrete Encased Ground Mechanical Reinforcing or Monolithic le Weatherproof / French Drain Sewer Service Lines Building Final Water Service Lines Fire Department "POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED R r DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED n e; FINALS Electrical Plumbing Mechanical /!7 le Roof Building Final Fire Department R.O.W $':Drainage `. INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY is ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY .NOR PERMISSION FOR OCCUPANCY.= PROTECT THIS CARD FROM THE WEATHER ♦ All i CITY OF WHEAT RIDGE '0000 Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: g�� Job Address: 7>n1 Tf! /y% 57 Permit Number: iai? 7e Pk /cJ� ❑ No one available for inspection: Time 5 A PM Re- inspection required: Yes When corrections have been made, call for re- inspection at 303 -234 -5933 Date: - AL V /o Inspecto DO NOT REMOVE THIS NOTICE "4' City of Wheat Ridge r Residential Mechanic PERMIT - 101296 PERMIT NO: 101296 ISSUED: 05/19/2010 1 JOB ADDRESS: 3701 TELLER ST,,: .EXPIRES:. 11/15/2.010. ? a DESCRIPTION:, Replace. 90,000 .. btu furnace * ** CONTACTS * ** owner. 720/429-6016 Mark & Teresa sub 303/233-5153 Richard Taylor 01-7784 Taylor Heating .;31 * *PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: UA BLOCK /LOT #: - 0/ 4 ** -FEE SUMMARY ** '.ESTIMATED PROJECT VALUATION: 2,000.00' FEES Permit Fee 40.00 °,'"*, , , Total Valuation 00 Use Tax 36. . 00 * *: TOTAL ** ..76.00 RIN Conditions: > Subject to field inspections. a I hereby certify that the setback distances proposed by th 'permit applicat' are accurate, and do not violate applicable: ordinances, rules or regulations of the City.. of Wheat Ri e,or covenan , easements .. or restrictions of record;.: that all measurements shown, legations made are accurate- hat h ead and agree to abide by all conditions printed on this application a hat I assume 11 responsibilit lance rth'the Wheat Ridge Building Code (I.B.C) and all other applicable eat. Ridge Ord nces, for work un this rmit. ans subject to field inspection. Signature f ontractor /owner date a 1. This permit was issued in accordance with the provisions set forth, in your application and is subject to the .laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date'. Requests for an extension must be received prior to expiration date:. An extension may be granted at the discretion of the Building Official. y 3. If this permit expires, a new permit may be acquired for a fee of .one -half the amount normally required, provided no a changes have been or will be made . in the original plans: and specifications and any suspension or abandonment has not exceeded one (1) year.. If changes have been or if suspension or abandonment exceeds one (1) year,.. full fees . shall r be paid for a, new permit.'. 4. No work of any manner shall be donee. that will change the natural flow of'. water' causing a drainage problem. x' 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance' for all inspections and shall receive a written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of =apermit or the approval of drawings and specifications shall not be construed to be apermitfor, nor an approval of', any violation of the provisions of the building codes or any other ordinance, law, rule or regulation All plan revi i ubject to field inspections. Signatureo i Building Official' date INSPECT ON REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 4 i ve 7 City of W heat R idge Date: - COMMUNITY DEVELOPMENT Plan # 1 / Building & Inspection Services Division Permit # 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303- 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303- 234 -5933 Building Permit Application Property Address 2/ � �e Property Owner (please print): : Phone: 7ZO C f 6 Mailing Address: (if different than property address) Address: 514 r,... City, State, Zip: Contracto%: ! y9 T �ri/- Contractors City License #: Phone: Jc' Sufi _Contract #ors:?. ��� Electrical. Plumbing: Mechanical: City License # City License # City License # Descrlh #�onofw�ork� �y �> 9 0 �(� �/ �� ^ Contract Value: J $ �' , Review Fee (due at time of submittal): Squares BTU's M Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I. have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform tyc scribed work and am also authorized by the legal owner of any entity included on this application to list that entity on thi pplication. CIRCLE ONE; /(OOWWWNN' }ER) (CONTRACTOR) gr (AUTHORIZED R RESE l V / E) of ( ER) ON RACTOR) PRINT NAm � 7�C�� F -ro —7 ,-' SIGNATU /i.A�`�`' DATE: g ^Z c7 1 � < .✓ �r� r « � < 1'� r „ � � < a ,^ S"�a� ) h ✓" l r N Y�e /7 %s' I �ewewer� > �l� � ri � � > "�� r r��+'c�s. ° r 1` '^'`''1'.". � �r t � <� r �� y r� r y rP F ✓ f ,/ r r ' 'te <�<^,� .a�, ,;r� J .., 2 .; r' � n t�^'"1Jr 4,�r`1' a �/ ss� �'�✓�' Uf / n r �� . , BUILDING DEP)1RTNJEI+ITCOMMENTS °'a � F `r�� � w„ � r rf f � � < i - „� v:� r� x ; ✓ r _ r i a �REVI0YJ2� .✓ ✓ � /� /rr ' � r✓ r�% r x r r C' r� 6�w< <" ar w ' i� r r �� / <� ✓ ��:� � it !< �� � Sfl � f < s �� r �� " r ✓ ✓ r :✓ �rj� � r ✓ , ,r � ✓ ) a ^"r r �' r � s +• � ✓ i< ti �� / r r � r l r < Y r rc' < i1 ✓ ', < r Pl78LIC WORKS CO M tilT ' ` '' � �' + ✓ ' < !Z u ; r i l� . ✓ � � ° x r r. < s r ✓- r . �P NCY �^ i a Q4 r Reviewer N ro < r r r �- �,r' e�¢ Y w ,�.$" A e✓;y< <TI at j s r !. FIRS dEPARTMENT O apProYad�w /cOyimetats i] disap�royed < L7 fly }evlew rQgU�r£d�; Bldg Valuation $ 0 s D N N Z ~ ~ rn O m ~ 2 ~ a ~ m ~ ~ ~ ~ ~ ' ~ ° < s v ~ c e t° < o O d e w ~ d ~ y m c . m a a ~ ~ \ I ~ ~ 2) ~ y Q O O ~ S~ ~ N Mi < 7 F ~ ~ ~ ~ ~ a °L ~ c~ 3 0 go a 0 O o a ~ ~ ~ N C ~ ~ ~ ~ * f ( j G ` C ~ o o~ ~ O da _ ° ~ m m n 1G ..O m ~ N ~ NN O 7 ~to < 3 d 0 y C. C 0 v ~ ~ Z o ~ N mN m ~ ~ m / m~ ~ m Z =I COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number : 16064 BUILDING INSPECTION LINE -(303-234-5933) Date : 8/15I2003 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Property Owner: TERESA PROKOP Property Address : 3701 TELLER ST Contractor License No. : 17152 Phone : 421-9893 Company : Precise Plumbing Phone : 534 0881 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certi(y that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED Description : REPLACE WATER HEATER Construction Value : $450.00 Permit Fee : $30.55 Plan Review Fee : $0.00 Use Tax : $0.00 Total: $30.55 Use: m BUILDING DEPARTMENT USE ONLY Zoniri,g;Gomments: SIC : Sq. Ft. : Approval : Zoning : Building Commenks*. Approval: Pubtic Works Comments:. Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No :17152 Mechanical License No : Company : Company :Precise Plumbing Company : Expiration Date : 10/18/2003 Expiration Date : Approval : OKIKS Expiration Date : Approval : Approval : (1) This permit was issued in accordance with the provisions set forth in yopur application and is subjed to the laws of the State of Colorado antl to the Zoning Regulations and Building Code of W heat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work aulhorized is nol commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) IF ihis permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will ba made in the original plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandanment ezceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural Flow of water causing a dreinage problem. (5) Contractor shall notify the Building Inspector lwenty-four (24) hours in advance for all inspections and shall receive written approval on inspeclion card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be consirued to De a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, mle or regulation. Ch?' ild' t r eas sign Terms and Conditions on reverse side of page. DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Nutnber: ' BUII,DING INSPECTION LINE - 303-234-5933 Date: CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) ~~UCATtON ProperryOwner. 7{r4>14 /••O~"~ Properry Address: ) '7 o /'j-r 11,e Phone :qa/- 9~'y 3 Contractor License No.: / '7 / 3 3. ComPanY P~r c i`s c P/~~ kl,L r. 2n c Phone: J~3 y o 8'~/ O WNER/CONTRACTOR SIGNATURE OF UNDEI2STAIVDING AND AGR6EMENT I heazby ceRify that ihe se[back Aistances proposed by tltis pernut applicatioa are accurate, and do not violate applicable ordinances, culaa ot rogulations of the City of Wheat RiAgc or covenants, easemenis ot rostrictians of rowrd; that all meuurements shown, md allegations mada ara accurata; that I have read md agree lo abide by aIl conditions pxinted on this applications md that I assume full respansibility far compliance wiN ihe Wheat Ridge Building Code (CJ.H.C) md nll other applicabla Wheat Ridge Ordinances, for work under this pemtit COIlSYSUCt10II V31U0: 5'0 Permit Fee: Plan Review Fee: TTcr TaxS0.ar.s Total: 3 0. rs' . SIGNP7J~~~_Ci/~ATF{ (OWNERHCOMRACTOR) Description: fe.O /19C ¢ "i Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Eatpiration Date: E7cpiration Date: Approval: Approval: Appraval: (1) 'iltis pemut wns issued in accocdence with qw provisions set forth in your applicatlon md is subject W the laws of the Stete of ColoraAo enA to the Zoning Regulatiorts md Bmldiog Code of Wheet Ridge, Colotedo a my oNer spplicable oidinmca ofthe City. (2) Tttis pemtie shall expire if (A) the work authorimd is mt commenceA within sixty (60) deys from issue date or (H) the bwlding auHwtized ix suspended or abandoned for a pwiod of 120 days. (3) If Utis pumit expuas, a new pevnit may be acquirod for a fee of one-helC the amovnl nwmelly reqvired, prwided m chenges have been or will be made in the onginal plazts md spmifica4orts md any ssspensiw w abmdoawent hes not excevlrA one (1) year. If changes have been x if suspension or abandorunent exceeds one (1) yeaz, full fees shall be peid for e new pewit. (4) No wack of any maruier sheLL be dom tMt will cheoge tIve mtwLL Row of water ceusing a d[einage pmblem (5) Conhactoc shall no4fy the Bvilding InspecWr twenty-four (24) hou[s m advance fw all iaspec4oN md shall receive wntten appewal on iaspection card befoce pmmedmg with succusiw phues of fhejo6. (6) The issuarme of a pemut ot the appiwal of drewings md specifications ilhnll not be comtved W be a pemut for, nor an appmval af, any nola4on of the pcovisions of che bvilding codu or nny othu ordinency law, rule or cegWation. CMef Building Inspector . . . ::.1 • r ~ . 4 ^I DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WWEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner : Property Address : 3701 TELLER ST Phone : 421-9893 Contractor License No. : 18091 Company : Sin Jac Electric Phone : 424 3898 Building Permit Number : 10201 Date : 3/8/00 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restridions of record; that all measurements shown, and allegations made are accurate; that I have read and ayree to abide by all condRions printed on this application, and that I assume full responsibililv for comPliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat aidge ordmances, for work under this permtt. Construction Value Permit Fee Plan Review Fee Use Tax $1,095.00 $41.80 $0.00 $16.43 $58.22 (OWNER)(CONTRACTOR) SIGNED DATE Description : Service change to 125 amp service Total Use: BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval : Zoning : Approval : Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: (1) This pennit was issued in aaordance with the provisions sel forth in yopur applicadon and is subject M the lawa of the Stele of Coloredo antl to the Zoning Regulatlons and Builtlin~ Cotle of Wheat Ridpe, Cobretlo or any other apDl~ble ordinances of the Ciry. (2) This pertnR shall ezpire d(A) the work euthonzed is not commencetl within sixty (BO) tlays irom issue tlate or (B) the builtling auMOrized is suspended or aEandoned for a periad of 120 Cays. (3) If this permtt expires, a new permit may he acquired for a fee of one-halt the amount nortnalry require4 provided no clianges have been or will be mede in the original plans end speUficadons entl any suspension or abandonment has not ezceetled one (t) year. If changes are matle or d suspansion or abandonment ezceeds one (7) year, Tull fees shall be peitl for a newpem~ tt. (4) No vrork of any manner shall be done that will chan9e tlie nalutal fiow ol waler causing a drainage problem. (5) Cantractor shall notiry the Building InsoecWr Avenry-four (24) hours in advance for all inspeclions and shall receive written approval on inspection cartl before proceetliirg with auccessive pheses of tha1'oD. (e) The issuance of a pertnH or the approval M drawirgs and specifiptions shall not be canstrued M be a permit tor, nor an approval of, any violation of the provisions of the builGM codea w am other ortlinance, law, rule or regulatbn. DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 APPLICATIo N PropertyOwner: ;,92t1k~` f 20kdf Property Address : 370i T Phone : 3«3 - yz/- pys~ Contrector License No. : f f~ L 9/ Company : , n. \;./d c ~ L F e7 Phone : 3 0 3 y 2 y- 3 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pertnit application are accurate, antl do not violate applica6le ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restnctions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all eonditions printed on this application, and that I assume full responsibiliry for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge rdinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ~ Z t'r L DATE 3 A ~C~ Description : ~ ~Ltux.c~ 12 .,,,.,...~,....~.,~I .oI.. . /C/ 9S_ Permit Fee : Use Tax : Total : Use BUILDING DEPARTMENT USE ONLY WIN[ . - - SIC : Sq. Ft. : Approval : Zoning : HuifBi Approval : ' Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No q Plumbing License No : Company : O~~, f`t cc F- Company : Expiration Date : Approval : Expiretion Date : Approval: Mechanical License No : Company : Expiration Date : Approval : (1) This pertnit was issued in aaortlance with the prodsions set Porth in yopur applitation and is su6ject to the laws ot the State ot Coloratlo anE W the Zoning Regulations antl BuilAing CoCe ol Wheat Ridge, Colo2CO or any oMer appliwble oMinances of Ne Ciry. (2) Th is permit shall expiro if (A) the work authorizetl is not commenceE wiNin sixty (80) Cays from iuue Eate or (B) the building authonxed is gu5pen0eC or abantlanetl for a penoE of 720 tlays. (3) If Mis pertnit expires, a new pertnit may be acquired for a fee of ono-hall the artwunt nortnalty requireE, provitletl no changes have Deen or will be maEe in the onginal plans antl specifiwtions arW any euspension or abantlonmmt has not exceeCetl one (1) year. It changes are ma0e or H suspension or aEanEOnment exceetls one (1) year, full fees ahall be paiA tar a new permR (4) No work of any manner shall be tlone Mat will Uange the naN21 fiow of water causing a 42inage problem. (5) Canvactor shall nofiy the Building Inspector lwenry-four (24) hours in advance tor all inspections anE shall receive written approval on inspection wM be/ore proceetliing with succesaive phases ot the 7"06. (6) The issuance of a pertnit or the aOProval of drawings anE specifications shall not be consWetl to be a pertnit far, nor an approval ot, any violation of Me provisions of the EuilCing codes a arry oMer oMinance, law, rule or regulaUon. Chief Building Inspector