Loading...
HomeMy WebLinkAbout3430 Ward Road1* � � i City of Wheat Ridge �� E -Res. Sewer/Waterline Repair PERMIT - 202001939 PERMIT NO: 202001939 ISSUED: 09/28/2020 JOB ADDRESS: 3430 Ward Rd EXPIRES: 09/28/2021 JOB DESCRIPTION: Installing sewer line, 20 feet in front yard. *** CONTACTS *** OWNER (303) 234-5678 FAWNS BRIAN A SUB (303)210-8207 TREVOR WESTON 110115 PREMIER EXCAVATION SERVICES *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 31500.00 FEES Total Valuation 0.00 Use Tax 73.50 Permit Fee 109.20 ** TOTAL ** 182.70 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. Sewer/Waterline Repair PERMIT - 202001939 202001939 ISSUED: 09/28/2020 3430 Ward Rd EXPIRES: 09/28/2021 Installing sewer line, 20 feet in front yard. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: Dina Kemp TO: Dina Kemp Subject: FW: Online Form Submittal: Sewer or Water Line Repair permit Application Date: Sunday, December 13, 2020 5:02:56 PM From: no-reply(cDci.wheatridge.co.us<no-repJ)1(cDci.wheatridge.co.us> Sent: Monday, September 28, 2020 11:51 AM To: CommDev Permits Subject: Online Form Submittal: Sewer or Water Line Repair Permit Application Sewer or Water Line Repair Permit Application This application is exclusively for SEWER OR WATERLINE REPAIR -IN YARD Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Right of Way permits must be applied for with the Public Works Department. Is this application for Yes sewer line or water line repair - in yard only? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 3430 Ward Rd Property Owner Name Brian Fawns Property Owner Phone (303)234-5678 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email N/A Address Attach City of Wheat Electronic Payment Form cityofwheatridae Ddf Ridge Electronic Payment Form - **DO NOT ATTACH A PICTURE OF A CREDIT CARD* Contractor Business Premier Excavation Services Name Contractor's License 110511 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone (303) 210-9745 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address trevor nremierex_net Retype Contractor Email Address DESCRIPTION OF WORK Is this a sewer line or Sewer Line water line repair? Length of repair 20' Location of repair Front yard (backyard, frontyard, etc) Provide additional details N/A including installation of clean -outs. Project Value (contract 3500.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Trevor Weston Permit Email not displaying correctly? View it in your browser. CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: _ F / F / Job Address: Permit Number: '- -771_5 ❑ No one available for inspection: Time ii SAMIPM Re -Inspection required: Yes t o s. When corrections have been made, schedule for re -inspection online at: http://www. ci. wheatridge. co. us/inspection Date: !1` ! 3 -70 1 c Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: F fF1 Job Address: Permit Number: cr? ❑ No one available for inspection: Time `. FNM Re -Inspection required: Yeo No When corrections have been made, schedule for re -inspection online at: http://www.ci. wheatridge.co. usrnspection Date://— C1'-4?67`>6 Inspector: cZ_'_P0 DO NOT REMOVE THIS NOTICE City of Wheat Ridge Homeowner Accessory Structure PERMIT - 202002033 PERMIT NO: 202002033 ISSUED: 10/21/2020 JOB ADDRESS: 3430 Ward Rd EXPIRES: 10/21/2021 JOB DESCRIPTION: Construct pergola to balcony above garage - 250 sq ft total *** CONTACTS *** OWNER ( 3 0 3) 875-9275 FAWNS BRIAN A& ELLENA *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 51500.00 FEES Total Valuation 0.00 Plan Review Fee 91.59 Use Tax 115.50 Permit Fee 140.90 ** TOTAL ** 347.99 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. If professionals are hired, those contractors are licensed with the City of Wheat Ridge and are listed on the permit. NOTE: Consultations and inspections will only be performed with the homeowner of record present. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. 1* � � i City of Wheat Ridge Homeowner Accessory Structure PERMIT - 202002033 PERMIT NO: 202002033 ISSUED: 10/21/2020 JOB ADDRESS: 3430 Ward Rd EXPIRES: 10/21/2021 JOB DESCRIPTION: Construct pergola to balcony above garage - 250 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Residential Accessory Structure (Garage, Shed over 120 sq ft, Gazebo) Date: Friday, October 9, 2020 9:34:47 AM Residential Accessory Structure (Garage, Shed over 120 sq ft, Gazebo) THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 3430 Ward Road Property Owner Name Brian and Ellena Fawns Property Owner Phone 303-875-9275 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email emfawns@gmail.com Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 2020 Oct Permit Peraola Ward Road.odf CONTRACTOR INFORMATION Contractor Business Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) 0 X 1918xarN�VA 09 Contact Email Address emfawns@gmail.com for Questions/Comments Retype Contractor emfawns@gmail.com Email Address DESCRIPTION OF WORK Detailed Scope of Add pergola to balcony above garage Work - Example: Detached Garage with Electrical; Unconditioned shed Square Footage of Accessory Structure Engineering Letters and Other Letter Size Attachments 250 Field not completed. Construction Plans 2020 oeraola olan.odf scanned on 11'x17" or larger Project Value (contract $5500 value or cost of ALL $5,500 Valuation OK materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Ellena Fawns Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. �rnp 99 p� ON SITE PLANS 5L/J(D / 19L un/=�jYI FITf [ON IN�SPf Cl10N W V •/li o Field Inspections Q I ora 'I tom w o ALL Lumvk, Posr, - 6 Xan C E09K - P05r3 A4s 5» vti w9tw 3r4n0nnn - 2x i0 - 0)/44 ux Yy'L445. /Teo 3o<rs .�iffAOf'$,4ZOS lK4 - �sr gg565 iMrro spopot, w4u aEtow A« &5se5�//oaca wl« 8=<.9cc9 " whrx APPRO D All mit SWI co�ly p181,w,AMelRI'd fi'lCoR - Randy Slusser�cm 10 I 3y -;o wgao Qn f oil ,a o,l�x � � Y I II 1 e 1 1 1 I al'aells 1. FN In the blaab with dimeredona and evwetlala which wilt be used to bW Id the swdel Maw PM, ICON L mdlate In the check bovu which di (ram Mille 4will be hied Mass nine If any of the sidrs of yow earpatt addition are closer than Volo to the properry Me. that sale M flit Carport must be mclmed with a solid 1 hour fire or wall as.Nown In Nternate Draft Band C. You most however, keep w leattrwo sides Of the carpo open lu ronform to the bulldln8eads rMW,emm[n. Zoning approval Is regWrt 8. hear to be Installed per manuhrcroul Inatmetlon; IntladNg Nw [Wove application and regWred Inspections made. RBof coundrighl PM Undalayment N SG and Am tdlags Shwthln Bond -oy 2 2zfQrratmrci O.C. xeb: walls, W wall tlow an SIO Its o�N wgisterllne W fah, raid Nen R ............... than eyR I W' ocwr omr j CqN Jhurub• mr"Ream ia4,p J Exlwall etawq haiNing n ern �- Mammr fiaev Spam xv Neral Mp oldapr jp1a11c Jrhe �ewtl d Mdam $1d� Alhaueform she a salve.X-*posts connemslm a•a spacetljj�apart do um Minimum b Pa Ping' Footing late analmWaa by Real 8—.ra—•• This ted We, amrom Made wRMWCmu,mee PELGocq oN ckr5iiuF ecaF Code eo..o-l. epapwmmr.m ro 2018 1,. «mm �w.u,a w 2 ovse Gq/..{pt aw.. Choice.an mrr, Danie em of Bulelrea ,l ex hallrpulrenanu. 3 Wheat Ridge Ga< -i i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: S U G Job Address: 3 3 5�a r - Permit Number: 'Z_-0 �!--® 0 % S ❑ No one available for inspection: Time rs '`AM PM Re -Inspection required: Yes N' _ When corrections have been made, schedule for re -inspection online at: httpYAvww.ci.wheatridge. co. usfinspection Date: 7//3a/%%7_020Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: 220 Permit Number: e2 i ❑ No one available for inspection: Tim AM/PM Re -Inspection required: Yes No When corrections have been m e, chedule for -Inspection ori"e at: http://www.ci.wheatridge.co.u' pe do 7;: DJ.- .1n... -pec _ � ' e City of Wheat Ridge Residential Solar PERMIT - 202000786 PERMIT NO: 202000786 ISSUED: 05/0'7/2020 JOB ADDRESS: 3430 Ward Rd EXPIRES: 05/07/2021 JOB DESCRIPTION: Installation of grid -tied solar PV system. No batteries. Flush -mounted to roof; on house *** CONTACTS *** OWNER (720)232-1069 FAWNS BRIAN A SUB (303)447-0300 JEFF DENOVAN 090413 NAMASTE SOLAR *** PARCEL, INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,600.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for L the first inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specificationst applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ennrt. I further attest that I am legally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4' No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permits all not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or adinance or r pilation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Permit Application (For permits which do not have a form already) Date: Tuesday, April 28, 2020 12:30:19 PM Permit Application (For permits which do not have a form already) This application is exclusively for Scopes of Work that do not already have a specific form. YOU MUST ATTACH AN ELECTRONIC PAYMENT FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 3430 Ward Rd Property Owner Name Brian Fawns Property Owner Phone 720-323-1069 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTACT INFORMATION Submitting General Contractor or Architect Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contract Phone Number (enter WITH dashes, eg 303-123- 4567) fawnsb@gmail.com Namaste Solar Electric Inc 090413 406-830-0812 Contact Email Address jacob.logar@namastesolar.com Retype Contact Email Address DESCRIPTION OF WORK Detailed Scope of Work - Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc. Location of work (backyard, on roof, etc) Project Value (contract value or cost of ALL materials and labor) Upload Engineer letter, other documents on 8 1/2" x 11 " Upload Asbestos Report if triggler level is met per CDPHE regulation. jacob.logar@namastesolar.com Installation of grid -tied solar PV system. No batteries. Flush - mounted to roof. System size Roof of house Field not completed. Upload Drawings 11 X FAWNS, BRIAN LEVEL 2.odf 17" or larger SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. Yes I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Jacob Logar Permit Email not displaying correctly? View it in your browser. Dg� Dont structural Engineering, Liti* OM CI 5 P.O. Box 6986 S—T R U C T U R A L Broomfield C080021 5308647055 #NG INCRR INC,, R11C Bomossmdual@gmaiiearn To Nam aste Solar 67AW inch gter Circe, Suite 700 Boulder CO 80301 Subject Certiffication Letter Forms Resign. all Rd Wheat Ridge, CO 80033 To Whom K Ngi Ajoefte observation ofthe Abroad ofthe exntingframing system was pefformed oven got team Omani a ponxe mantled a provided nomination a true and source from DomoStructural Rini All dowels paper meaeomeeatioosammeLogo o,tem rated below and On the above referenced project,the raffstructuraframing his been reviewed mraddhDanal leading fietathe regulation eonxapples to Respond ofthe mi is firect"upporningthe solarPopetern elements The observed eonstmstmn. oorrmmmg a London below road condition, dine., .ommos�m+�gmee.pnn The.aors..ustu.e orlRoonl Cama' meomposmon shingle an genetics is supported bvns.amem a 24 aewith A With helped .meaare Annexed ..herdeem a deep board and a.esuppoaed a..he eak w mse degrees The load Andres alis The e.m Stuctural rem, of (Roof al Ndgeno bedmdepaetowmstand theleam,g imposed yine installation or meson sto re!s.mt now26Doug reinforcement a.opmree..memberwith a repm.edm. �Rooncon all rupee that dnestx i., �mmto imp,onRnw moo,aeosAdgsea.fid me Ad Theigaing offtheadarstandom should be kept at 72 a c for landscape and ON a c for porous mentai a staggered pg.e.n.o ensure proper distribution ofloods. nee.xng an supporting Theampe is report is strity limited to an evaluation dome fastener confident, Structure x�,nRotation of loading All pai racking and hardwarelhall be installed per manufacturerapeciffications and within a AskedLogo unitations All water roofings hall be provided bythe manufacturer Donnus Structural Engineering ansurned noreoponothisfor mouse or improper installation oi panels cracking not reemreesmreSao da; amsenmmoesga Categay(eoL)<e • Applicable Codes 2012 evi ASCE 710 • Roof Dead Dead=s par (door s) • Roof Los Lead 20 par • Wind Speed 135 mph rymJ, r pmnreS Risk Category u • Roof Sri. Lead 30 par 16 do lags causys 2 5 inch embedment depth/ min atspamgshmm above Edge contact me with anyourther questions or concerns beganduch's paject Sincerely Ryan Atwell P E Edged Engineer O e'P�dO g1FN`�E� 0510 (o �NALE�V Ryon ANvell etkvAdd wM Me w Fans Reodence Meat Ri[ i� DQMPIS a15Rod Remus Structural Engineering, LLC — Weight on PV System (Per Nanazte Solar) 30 pA PO.Box 6986 S-T R U C T U R A L Y CAndoll Spacing= 2]6X Broomfield CO 80021 1100A Point Wada N Slartltlls 33 lb 90.861]055 N C F N C R N a N Cr, A P C Demussructual@g me it com Grrviry Loading pe=Ground Snow War- .Popo p=OC,GIpe (ACCP-E]-1) C, - Exposure Factor= 1 (ACCP -racers) G=Thermal Factor= 1 (ACP-Tabe7C) =1mpoRanreFactor= 1 p=FM Rmr Snow War- too 0Rod Ps CA (ACCP-E]-2) Cs=Slope Factor= 1 A Supped Pml Auv Wady POolsl ad Dead Wal v l p9 der Pau le Solar) DL Adjusted 10 18 Agree Slope a15Rod ad System NRight — Weight on PV System (Per Nanazte Solar) 30 pA X CAndoll Spacing= 400X Y CAndoll Spacing= 2]6X 6hnNll TAbuhry, Sea= 1100A Point Wada N Slartltlls 33 lb None: PV standoffs aregaggerea to ensure proper distnbulon on loading Ra l ua Ward -x0 W None Ad lies load is removed in areas covered by PV army Pod Rad Wad (ba 1) Composition Shingle 400 PoN Plywood 200 Found 25 Rogers ®24"oc 230 Vernon Ceiling 000 (Ceiling NA Vernon) Miscellaneous 070 Total Red DL)Pmli) molal DLAdimiedto l8 Agree Slope 95Rod Fawns Residence, Wheat F oomus Structural Engineering, LLC DOM CIS PO Box 6986 i} T R U C T U R A L Broomfield CO 80021 5308647055 NG T N E E R P N or is I1C Oomusstructual@gmail. corn Wind Calculation_ Per ASCE ]-10 Components and Cladding Input Varl mind ed tegory Exposure caa> apn PoA Shape Hp/Oable Poolelope 18degreea Wan Pool lkigbt 20P Woods, WndNea 193N Design Wind Pressure LaleulAuns Wind Pressure P vyM6'Ln ph- 696256• K, a St Nd• Vi' IN303-11 K, Exposure 0nercioem1=09 used 30-11 Ka topographic fauna= 1 169.26811 ad Mind Vire.Lonaldy Faced) =695 (Table 26611) V (Design Wind Speed) -135 mph (To 2651A) Rick Senators =ll Fare 1d111 9h= 3599 0Rado-2142 3andofl OplM LalculAuns Porti Zone 1 Zone 2 Zone N ftso 00p= L94 -139 -213 636 169 36111 Lplm Fssmre=-1395ago -29.77ps 47 71 134per XStanann Spring= 866 496 291 YStandofl Spring= 215 215 215 Tric Rae= 1196 1106 133 routing OpIR= -07111 327 111 dm lL 30ndoN OpIR Lakuladonslanderape Zone 1 Zone 2 Zone N ftso 00p= L94 -139 -213 636 169 36111 LplfaRescue =-1795ago -29.IIps -01I1per 100per 1shimuml %Standof Spring= 696 696 406 YStandofl Spring= 175 175 175 Tric - 1050 1050 100 routing upiR= -Ba ib 813 ie aLle mammnm Desanaplm=- m aandnn open oedy= This m as6mremay>356mdemand memea,Ox reasoner;F14L� CRIMP iaad g� Numberol Farmners= l Embadmam Depth= 25 CbU Nlmw Capacity Per Inch= 256m Fastener Capacity- 265m 4 F8off 58 DOL of 1 T -661m 6672m capacty>350 to demand mnogre,OK Fawns Residence wheatRidgs i� Remus Structural Engineering, LLC DQMPIS PO.Box 6986 S -c- T R U C T U R A L Broomfield CO 80021 90.861]055 NQ TNERR INC, LLC Demussructual@g me it com _Framing Check (Root 1) PASS Sol Framing BFgn@s w=w5 Pff Dead Load 9b PA PV Led a2Rod Show Load PoOPAmble 25ffessi Pbt. Governing lmtl Combo -Di Member CPan=11'-w" Se Food Wad Rapid Member Rofer ies-Basel on Bfgn@d 3eNon Member Size 8QPCi) Iidea) LumberGp/Gr Member Spacing Double 25 1513 4159 BF10 ®24"Ce Mock Sending 9mi PoFel) = f A Ctl A Tr A Cr (NDS Table 431) 900 A 115 z 13 z 115 Allowed Bending Stress =1547 a psi Maximum Moment-dFw)1A =ID501w XA =1740216 in# Actual Bening Press- (M&lmum MomerA)/ S 11506psi FAeneda refund -A4%9remed - Therefee, 0 Marra noaonim Allowed Wllectlon(Total Load) = w (E= 1 Shown psi Per NDS) 0777In Detlectlon CMerh Basel on = Continuous Span Actual Detlechon(Total Led) _ (romp)10 WF 1) 02221n =W31 > Ll SO Therefore OR Allowed Deduced (Dva Load) = 1240 0Rain Actual Dellechon Fred Load) _ (romp)10 WF 1) 0157 in LR92 > ban Therefore OR Chock %ear Member Area =16502 Fvpsi) =1Npsi (NDS TE MoundShear =w•A-2970to Max Shear M=w'L12= s Flloneda refund -163%9ressed-Therefee, 0 LR'd Fawns Residence, wheal Rid (E) (E; 1X DECKING OR SHEATHING (N) INSTALL SIMPSON A34 CLIP. (N) SISTER MEMBER TO BE FULL LENGTH. ATTACH TO (E) RAFTER W/ SIMPSON SDVV22300 SCREWS STAGGERED TOP AND BOTTOM @ 16" O.C. MINIMALLY NOTCH NEW ` (E) CEILING JOIST SISTER RAFTER TO BEAR DIRECTLY ON (E) TOP PLATE OF WALL. OPTION 1 - FULL LENGTH SISTER SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE. SISTER RAFTER TO BEAR DIRECTLY ON (E) TOP PLATE OF WALL. OPTION 2 - OVERLAPPED SISTER (N) INSTALL SIMPSON A34 CLIP. TER MEMBER TO BE FULL IGTH. ATTACH TO (E) RAFTER W/ PSON SDVV22300 SCREWS kGGERED TOP AND BOTTOM @ O.C. SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE. (N) SISTER RAFTER ycity of (N) SISTER RAFTER (E) RAFTER SECTION A -A NNww���777711FF����^^� SISTER UPGRADE OPTIONS ALTERNATIVE FASTENER SCHEDULE: 10d NAILS STAGGERED TOP AND BOTTOM AT 6" O.C. Domus Structural Engineering, LLC. P.O. BOX 6986 Project Number: Solar PV Project Description: Rafter sister upgrade detail and Drawn By: JAC Drawing Name: Broomfield, CO 80021 specifications. Revisions: (530) 864-7055 A S i S i Domusstructural@gmail.com B LG345N1 C -V5 LG350N1 C -V5 345W 1 350W The LG NeONO 2 is LG's best selling solar module, and is one of the mo powerful and versatile modules on the market today. Featuring LG's Ce Technology, the LG NeONO 2 increases power output. New updates inc an extended performance warranty to 90.08% to give customers highE performance and reliability. APPROVED PRODUCE ED E C UL US M564573a=ENs,zsPh­­Mod��� Features 1111111111111 0 Enhanced Performance Warranty LG NeONO 2 has an enhanced Enhanced Product Warranty LG has extended the warranty of the performance warranty. After 25 NeONO 2 to 25 years including labor, years, LG NeONO 2 is guaranteed at which is top level in the industry. least 90.08% of initial performance. Better Performance on a Sunny Day ® LG NeONO 2 now performs better on sunny days, thanks to its improved temperature coefficient. About LG Electronics ♦ Roof Aesthetics LG NeONO 2 has been designed with aesthetics in mind using thinner wires that appear all black at a distance. The LG NeONO 2 can increase the aesthetic value of your home with a more modern design. When you go solar, ask for the brand you can trust: LG Solar LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems. The company first embarked on a solar energy source research program in 1985, supported by LG Group's vast experience in the semi -conductor, LCD, chemistry and materials industries. In 2010, LG Solar successfully released its first MonoXO series to the market, which is now available in 32 countries. The NeONO (previous MonoXO NeON), NeON02, NeON02 BiFacial won the "Intersolar AWARD" in 2013, 2015 and 2016, which demonstrates LG's leadership and innovation in the solar industry. dly d LI . �:s.Zaza: LG NeON®2 1_13345MC45 I 1_13350MC45 General Data Cell P FOP erose(M soon aVType) Monocrystallme/N-type CellMaker ITS Cell Configuration 60 Cells (6 x 10) Number of Busbare 12EA Me dine Di menei on a(L x W x H) 1686mm x 1016 mm x 40 mm Weight 171 kg Glass (Material) Tempered Glass with AR Coating Backsheet(Color) White Frame (Material) Anodized Aluminium Junction Box(Pmtection Degree) IP 68 with 3 Bypass Diodes Cables (Length) 1 OOOmmx SEA Connector (Type/Maker) MC 4/MC Certifications and Warranty Certifications IEC 61215-1/-1-1/22016, IEC 61730 1/2 2016, UAL 1703 ISO 9001,ISO 14001,ISO 50001 OHSAS18001 Salt Mist Corrosion Test IEC 61]01: 2012 Severity6 Ammonia Corrosion Test IEC 62]16:2013 Module Fre PermmlanCP Type 1 (UL 1]03) Fire Rating Class C (UL 790, ULAORD C 1 ]03) Solar Module ProductWarranty 25Y Years Solar Module Output Warranty Lin®r Warmnry* empmved:l at year 98%from 2 -24th year: 033%/year down, after25M year: 9008% Temperature Characteristics NMOT* [°C] 4213 Pmax [%/°C] -036 Voc [%/°C] -0.26 Isc%/°C] 789 003 SC MOT (Nominal Module Operating Temperature): Irradiance 800 W/raj Ambient temperature 20 °C, Wind speed 1 Ms, Spectrum AM 1 5 Electrical Properties (NMO Model P LG345N1C-V5 LG350NlC-V5 Maximum Power(Pmax) [W] 259 262 MPP Voltage Aorta) [V] 328 33.2 MPP Current(Impp) [A] 789 791 Open Cumit V0LagP Ab C) [V] 388 389 Short Circuit Current(Is) [A] 849 852 I-V Curves 120 100 80 Q 60 V 40 20 00 00 100 200 300 400 Voltage V) (a LG LIM d ITS Electronics Ino Solar Business Division 2000 Millbrook Drive Lincolnshire lL 60069 wwwlg-solarrom Electrical Properties (STC*) Model LG345N1 C -V5 LG350NlC-V5 Maximum Power(Pmax) [W] 345 350 MPPVoltage(Vmpp) [V] 349 353 MPP Onent(Impp) [A] 989 992 Open ❑rcult VOltage(V0g+ SA) [V] 41.2 413 Short❑rcuit Current(Ist,*5%) [A] 1057 10.61 Module Efficiency [%] 20.1 204 Power Tolerance [%] 0— 3 'STC (Standard Test Condition): Irradiance 1000 W/m', cell temperature 25 °C, AM 1 5 "Measuremend Tolerance +3% Operatinq Conditions operating Imperatore [°c] -40,90 Maximum System Voltage IV] 1,000 Maximum Series Fuse Rating [A] 20 MechaniaLTest load ( Fmn[) [Pa/psf] 5,400/113 Mechanical Test load (Rea r) [Pa/psf] 4,000/835 SAechanical Test Load 5400Ra/4,000Pa based on IEC 6121 &2:2016 Tesuoad -Design ready safety Factor (1 s) Packaaina Confiauration Number of Modules per Pallet [EA] 25 Number of Modules per 40ft HQ Container [EA] 650 Packaging Box [Smensions(LxWxH) [mm] 1,750 x 1120 x 1,221 Packaging Box Gross Weight [kg] 464 Dimensions Product specifications are subject to Change without notice. LG34535ONlC-V5.pdf M 2019 L6 Electronics. All rights reserved. Power Optimizer Specifications — P300 / P350 / P400 / P405 Power Optimizer Specifications - P300 / P350 / P400 / P405 P300 P350 P400 P405 THR PHASE INPUT Minimum String Length (Power Optimizers) 8 10 Rated Input DC Power(') 300 350 400 405 W Absolute Maximum Input Voltage (Voc) 48 60 80 125 Vdc MPPT Operating Range 8-48 8-60 8-80 12.5-105 Vdc Maximum Short Circuit Current (Isc) of connected PV Module 10 Adc Maximum DC Input Current 12.5 % Maximum Efficiency 99.5 % Weighted Efficiency 98.8 Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL -94 (5 -VA), -V Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(WxLxH) 141 x 212 x 40.5/ 5.55 x 8.34 x 1.59 mm/in Weight (including cables) 950/2.1 g / Ib Input Connector MC4 / Tyco / Amphenol Output Wire Type /Connector Double Insulated; Amphenol Output Wire Length 0.95/3.0 1.2/3.9 m/fi Operating Temperature Range -40-+85/-40-+185 'C /-F Protection Rating IP65 / NEMA4 Relative Humidity 0- 100 % ui Rated STC power of the module. Module of up to +596 power tolerances allowed PV SYSTEM DESIGN USING SOLARED NVERTER SINGLE PHASE THREE PHASE 208V THR PHASE Minimum String Length (Power Optimizers) 8 10 18 Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes SoiarEdge Power Optimizers solar[' -.. a Power Optimizer Specifications — P300 / P350 / P400 / P405 141 OUTPUT INPUT 1 11 111111111111111 E Soli Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE10000H-US / SE1140OH-US 3 U. t ! E qr W Optimized installation with HD -Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 111 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small Built-in module -level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) solaredge.com solar= .. z Single Phase Inverter Wit H D -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER OUTPUT SEXXXXH-XXXXXBXX4 Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 1400 @ 240V VA Maximum DC Power @208V - 3300 @ 208V - 5000 @ 208V - - 10000 @ 208V W Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 480 3300 @ 208V Nominal DC Input Voltage 5000 @ 208V 380 10000 @ 208V Vdc AC Output Voltage M in. -Nom. -Max 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2) (211 - 240 - 264) ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac AC Output Voltage M in. -Nom. -Max 45 Adc Reverse -Polarity Protection Yes (183 - 208 - 229) Ground -Fault Isolation Detection ✓ - ✓ - - ✓ Vac AC Frequency (Nominal) 59.3 - 60 - 60.50) HE Maximum Continuous Output 125 16 21 25 32 42 47.5 A Current @2403 < 2.5 W Maximum Continuous Output Current @2083 16 - 24 - - 48.5 A Power Factor 1, adjustable -0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2) - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600kv Sensitivity Maximum Inverter EtBciency 99 99.2 % CEC Weighted EtBciency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W 0 For other regional settings please contact SolarEdge support er A higher current source may be used, the inverter will limit its input current to the values rated Single Phase Inverter Wit H D -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Zig Bee(optional), Cellular (optional) Revenue Grade Data, ANSI C122 Optional(' Inverter Commissioning with the SetApp mobile application using built in W-Fi Access Point for local connection Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C222, Canadian AFCI according to T.LL. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (Hp Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AW6 1" Maximum /14-4 AW6 DC Input Conduit Size/# of Strings/ AWG Range 1^ Maximum /1-2 strings/14-6 AWG 1" Maximum /1-3 strings/14-6 AWG Dimensions with Safety Switch in/ 17.7 x 14.6 x 6.8/ 450 x 370 x 174 21.3 x 14.6 x 7.3/ 540 x 370 x185 (HxWxD) mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 Ib/kg Noise < 25 <50 SEA Cooling Natural Convection Operating Temperature Range -40 to +140 /-40 to +60(4) °F/ °C Protection Rating NEMA 4X (Inverter with Safety Switch) re Revenue grade inverter P/N'.SExx:H-Fx000BNC4 on Full power up to at least 501 / 122T, for power derating information refer to hugs A. sold red ge mm/steAd efaulVfil es/se-temperaturwdea➢ng-notwna Act ® SolarEtlge Technologies, Inc. All rights reserved SOW2EDGE, the Egresses logo, OPTIMIZED BV SOW2EDGE are trademarks or registered trademarks of Egresses Technologies, Inc.Al oilier trademarks mentioned herein are trademarks of their respective owners. Date'. Z 2019N01/ENG NAM. Subject to change without notice. All. I RON RI DGE The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric \ load path. Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Flush Mount System components. 'Q� \\ FlashFoot2 14 1 Three -Tier Water Seal FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS -100 Wind -Driven Rain Test. Water -Shedding Design An elevated platform diverts water away from the water seal. Installation Features B A c A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. B Rounded Corners Makes it easier to handle and insert under the roof shingles. CO Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading 1200 Traditional solar attachments have a FlashFoot2 1000 horizontal offset between the rail and lag soo bolt, which introduces leverage on the lag u Q 600 bolt and decreases uplift capacity. u � 400 FlashFoot2 is the only product to align the 200 rail and lag bolt. This concentric loading design results in a stronger attachment for 0 the system. Testing & Certification Structural Certification Flash Foot Leading Competitor I C Rail -to -Lag Offset (in) Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. `0 Low -Cost Competitor Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 3 1495 Zephyr Avenue AA IRONRIDGE Hayward, CA 94544 1-800-227-9523 Iron Ridge.com Attn: David F. Taggart, VP Products, IronRidge Inc. Date: March 28°. 2017 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of Iron Ridge's Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX -0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference standards for the load conditions and configurations tabulated in the attached span tables: ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) 2015 International Building Code (IBC -2015) 2015 Aluminum Design Manual (ADM -2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 0- to 450. The span tables are applicable provided that the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 450 or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 40". 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. 92017 IronRidge Inc ab« CO Flush Mount Syster 1495 Zephyr Avenue //l IRONRIDGE Hayward, CA 94544 1-800-227-9523 Iron Ridge.com The parameters and adjustments allowed in the span tables are defined as the following: 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-10 Chart 1.5-1. 2. When designing with a roof slope not listed in the span tables, but no greater than 45°, the lesser of the two span values listed immediately below and above the desired slope shall be used. For instance, if one is designing to a roof slope of 12°, use the lesser of the two span values associated with 100 and 150. 3. The wind speed selection shall conform to ASCE 7-10 Fig. 26.5-1A (Risk Category II wind) and any state & local county/city amendments to the IBC. No special wind topographic features are included in the span tables and the topographic coefficient (Kzt) is taken as 1.0. 4. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig. 7-1. If a more restrictive snow load is imposed by a local building codelamendment to the IBC, such snow load requirement shall also be complied with. If the local jurisdiction specified snow load is in the format of a flat roof snow load, it shall first be converted to a ground snow following the local building codelamendment before the application of the attached span tables. No special snow conditions are considered including unbalanced, drifting, sliding or ponding snow. Snow load conditions presented in the span tables do not include buildings which are intentionally kept below freezing, kept just above freezing, or unheated. 5. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: 1) For ground snow no greater than 42psf: Ss < 2.Og for Site Class A, B, C, or D. 2) For ground snow greater than 65psf: Ss < 1.0g for Site Class A, B, C, or D. 3) For ground snow between 42 and 65psf: Ss < 1.5g for Site Class A, B, C, or D. 6. Roof zone size and definition conforms to ASCE 7-10 Fig. 30.4-2A. 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. 8. An array to roof clearance of 2 inches minimum must be provided. 9. The maximum cantilever length measured from the rail end to the nearest attachment point shall not exceed 40 of the allowable span provided for the respective load & configuration condition from the span tables. 10. No rail splices are allowed in the cantilever, outer 2/3 of end spans, or middle 1/3 of interior spans. 11. For shaded cells of the span tables, UFO Mid Clamps shall not be installed closer than 20 inches to Roof Zone 3. 12. When a roof attachment listed in Iron Ridge's Flush Mount installation manual is considered, the span values provided in this letter can be adjusted using IronRidge's online Design Assistant by checking the capacity of the selected roof attachment against the reaction forces provided in Design Assistant. pb a yrXM"b��n 920171ronRidge, Inc CO Flush Mount Sy /lA IRONRIDGE 1495 Zephyr Avenue Hayward, CA 94544 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, ��PDO L6-- v ..�PNG X�� ;SFO 0050891 Gang Xuan, PE, LEED AP Senior Structural Engineer © 2017 IronRidge, Inc. CO Flush Mount System Certification Letter - 3 Flush Mount System Span Table (inches) Portrait Installation (Maximum Module Length 67.5") Exposure B Wind Roof Ground Snow: 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf Speed (mph) Slope (degs.) Zone -I T Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 5 118 104 83 98 98 83 83 83 83 81 81 81 73 73 73 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 10 116 104 84 96 96 84 81 81 81 80 80 80 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 115 103 83 95 95 83 80 80 80 76 76 76 67 67 67 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 113 101 82 95 95 82 80 80 80 76 76 76 67 67 67 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 110 25 112 100 82 95 95 82 81 81 81 77 77 77 68 68 68 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 110 110 110 96 96 96 82 82 82 79 79 79 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 109 109 109 97 97 97 85 85 85 83 83 83 74 74 74 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 108 108 108 99 99 99 1 88 88 88 87 87 87 78 78 78 71 71 71 66 66 66 61 61 61 57 57 57 54 54 54 107 107 107 102 102 102 92 92 92 91 91 91 85 85 85 78 78 78 72 72 72 68 68 68 63 63 63 60 60 60 5 118 99 79 98 98 79 83 83 79 81 81 79 73 73 73 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 10 116 100 80 96 96 80 81 81 80 80 80 80 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 115 98 80 95 95 80 80 80 80 76 76 76 67 67 67 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 113 97 79 95 95 79 80 80 79 76 76 76 67 67 67 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 115 25 112 96 78 95 95 78 81 81 78 77 77 77 68 68 68 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 107 107 107 94 94 94 82 82 82 79 79 79 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 106 106 106 96 96 96 84 84 84 83 83 83 74 74 74 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 105 105 105 98 98 98 87 87 87 86 86 86 78 78 78 71 71 71 66 66 66 61 61 61 57 57 57 54 54 54 105 104 104 100 100 100 90 90 90 90 90 90 84 84 84 78 78 78 72 72 72 68 68 68 63 63 63 60 60 60 5 118 95 76 98 95 76 83 83 76 81 81 76 73 73 73 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 10 116 96 77 96 96 77 81 81 77 80 80 77 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 115 94 76 95 94 76 80 80 76 76 76 76 67 67 67 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 113 93 76 95 93 76 80 80 76 76 76 76 67 67 67 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 120 25 112 92 75 95 92 75 81 81 75 77 77 75 68 68 68 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 104 104 104 93 93 93 81 81 81 79 79 79 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 103 103 103 94 94 94 83 83 83 82 82 82 74 74 74 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 103 102 102 96 96 96 86 86 86 85 85 85 78 78 78 71 71 71 66 66 66 61 61 61 57 57 57 54 54 54 102 101 101 98 98 98 89 89 89 88 88 88 83 83 83 78 78 78 72 72 72 68 68 68 63 63 63 60 60 60 5 115 87 70 98 87 70 83 83 70 81 81 70 73 73 70 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 10 116 88 71 96 88 71 81 81 71 80 80 71 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 115 87 71 95 87 71 80 80 71 76 76 71 67 67 67 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 113 86 70 95 86 70 80 80 70 76 76 70 67 67 67 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 130 25 112 85 70 95 85 70 81 81 70 77 77 70 68 68 68 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 99 98 98 90 90 90 79 79 79 77 77 77 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 98 97 97 91 91 91 81 81 81 80 80 80 74 74 74 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 97 96 96 93 93 93 83 83 83 82 82 82 77 77 77 71 71 71 66 66 66 61 61 61 57 57 57 54 54 54 97 95 95 95 95 95 86 86 86 86 86 86 81 81 81 76 76 76 72 72 72 68 68 68 63 63 63 60 60 60 5 107 81 65 98 81 65 83 81 65 81 81 65 73 73 65 67 67 65 61 61 61 57 57 57 54 54 54 51 51 51 10 111 82 66 96 82 66 81 81 66 80 80 66 70 70 66 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 109 81 66 95 81 66 80 80 66 76 76 66 67 67 66 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 107 80 65 95 80 65 80 80 65 76 76 65 67 67 65 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 140 25 106 80 65 95 80 65 81 80 65 77 77 65 68 68 65 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 94 92 92 87 87 87 77 77 77 76 76 76 69 69 69 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 93 91 91 88 88 88 79 79 79 78 78 78 72 72 72 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 93 90 90 90 90 90 81 81 81 80 80 80 76 76 76 70 70 70 66 66 66 61 61 61 57 57 57 54 54 54 92 89 89 91 89 89 84 84 84 83 83 83 79 79 79 75 75 75 71 71 71 68 68 68 63 63 63 60 60 60 5 100 75 60 98 75 60 83 75 60 81 75 60 73 73 60 67 67 60 61 61 60 57 57 57 54 54 54 51 51 51 10 104 76 62 96 76 62 81 76 62 79 76 62 70 70 62 63 63 62 57 57 57 54 54 54 51 51 51 47 47 47 15 102 76 62 95 76 62 80 76 62 76 76 62 67 67 62 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 101 75 61 95 75 61 80 75 61 76 75 61 67 67 61 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 150 25 99 75 61 95 75 61 81 75 61 77 75 61 68 68 61 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 89 86 86 84 84 84 75 75 75 74 74 74 68 68 68 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 89 85 85 85 85 85 77 77 77 76 76 76 70 70 70 66 66 66 61 61 61 56 56 56 53 53 53 51 51 51 40 88 85 85 87 85 85 79 79 79 78 78 78 74 74 74 69 69 69 66 66 66 61 61 61 57 57 57 54 54 54 88 84 84 88 84 84 81 81 81 81 81 81 77 77 77 74 74 74 70 70 70 67 67 67 63 63 63 60 60 60 5 93 70 57 93 70 57 83 70 57 81 70 57 73 70 57 67 67 57 61 61 57 57 57 57 54 54 54 51 51 51 10 97 72 58 94 72 58 79 72 58 78 72 58 70 70 58 63 63 58 57 57 57 54 54 54 51 51 51 47 47 47 15 96 71 58 93 71 58 79 71 58 76 71 58 67 67 58 60 60 58 54 54 54 51 51 51 47 47 47 45 45 45 20 95 71 58 93 71 58 79 71 58 76 71 58 67 67 58 60 60 58 55 55 55 51 51 51 47 47 47 45 45 45 160 25 94 70 57 93 70 57 79 70 57 77 70 57 68 68 57 61 61 57 56 56 56 52 52 52 48 48 48 46 46 46 30 85 81 81 82 81 81 73 73 73 72 72 72 67 67 67 62 62 62 57 57 57 54 54 54 51 51 51 47 47 47 35 85 81 81 83 81 81 75 75 75 74 74 74 69 69 69 64 64 64 61 61 61 56 56 56 53 53 53 51 51 51 40 84 80 80 84 80 80 77 77 77 76 76 76 72 72 72 68 68 68 64 64 64 61 61 61 57 57 57 54 54 54 45 84 79 79 84 79 79 79 79 79 78 78 78 75 75 75 72 72 72 69 69 69 66 66 66 62 62 62 60 60 60 5 88 66 53 88 66 53 83 66 53 81 66 53 73 66 53 67 66 53 61 61 53 57 57 53 54 54 53 51 51 51 10 92 67 55 92 67 55 78 67 55 77 67 55 70 67 55 63 63 55 57 57 55 54 54 54 51 51 51 47 47 47 15 91 67 54 91 67 54 77 67 54 76 67 54 67 67 54 60 60 54 54 54 54 51 51 51 47 47 47 45 45 45 20 90 67 54 90 67 54 77 67 54 76 67 54 67 67 54 60 60 54 55 55 54 51 51 51 47 47 47 45 45 45 170 25 88 66 54 88 66 54 78 66 54 76 66 54 68 66 54 61 61 54 56 56 54 52 52 52 48 48 48 46 46 46 30 81 77 77 79 77 77 71 71 71 70 70 70 66 66 66 61 61 61 57 57 57 54 54 54 51 51 51 47 47 47 35 81 76 76 80 76 76 73 73 73 72 72 72 68 68 68 63 63 63 60 60 60 56 56 56 53 53 53 51 40 81 76 76 81 76 76 74 74 74 74 74 74 70 70 70 67 67 67 63 63 63 60 60 60 57 57 57 54 45 80 75 75 80 75 75 77 75 75 76 75 75 73 73 73 70 70 70 67 67 67 64 64 64 62 62 62 60 5 83 62 50 83 62 50 83 62 50 81 62 50 73 62 50 67 62 50 61 61 50 57 57 50 54 54 50 51 10 87 64 52 87 64 52 77 64 52 76 64 52 70 64 52 63 63 52 57 57 52 54 54 52 51 51 51 47E 15 86 63 52 86 63 52 76 63 52 75 63 52 67 63 52 60 60 52 54 54 52 51 51 51 47 47 47 45 20 85 63 51 85 63 51 76 63 51 75 63 51 67 63 51 60 60 51 55 55 51 51 51 51 47 47 47 45 180 25 84 63 51 84 63 51 77 63 51 75 63 51 68 63 51 61 61 51 56 56 51 52 52 48 48 48 46 30 78 73 73 77 73 73 69 69 69 69 69 69 64 64 64 61 61 61 56 56 56 54 54 51 51 51 47 35 77 73 73 77 73 73 71 71 71 70 70 70 66 66 66 62 62 62 59 59 59 56 56 E63 53 53 53 51 40 77 72 72 77 72 72 72 72 72 72 72 72 68 68 68 66 66 66 62 62 62 59 59 56 56 56 54 45 77 72 72 77 72 72 74 72 72 74 12 12 71 71 71 68 68 68 66 66 66 63 63 61 61 61 59 Flush Mount System Span Table (inches) Portrait Installation (Maximum Module Length 67.5") Exposure C Wind Roof Ground Snow: 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf Speed (mph) Slope (degs.) —Zone -1 T Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 5 115 87 70 98 87 70 83 83 70 81 81 70 73 73 70 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 10 116 88 71 96 88 71 81 81 71 80 80 71 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 115 87 71 95 87 71 80 80 71 76 76 71 67 67 67 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 113 86 70 95 86 70 80 80 70 76 76 70 67 67 67 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 110 25 112 85 70 95 85 70 81 81 70 77 77 70 68 68 68 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 99 98 98 90 90 90 79 79 79 77 77 77 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 98 97 97 91 91 91 81 81 81 80 80 80 74 74 74 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 97 96 96 93 93 93 1 83 83 83 82 82 82 77 77 77 71 71 71 66 66 66 61 61 61 57 57 57 54 54 54 97 95 95 95 95 95 86 86 86 86 86 86 81 81 81 76 76 76 72 72 72 68 68 68 63 63 63 60 60 60 5 110 83 67 98 83 67 83 83 67 81 81 67 73 73 67 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 10 114 84 68 96 84 68 81 81 68 80 80 68 70 70 68 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 112 83 68 95 83 68 80 80 68 76 76 68 67 67 67 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 110 83 67 95 83 67 80 80 67 76 76 67 67 67 67 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 115 25 108 82 67 95 82 67 81 81 67 77 77 67 68 68 67 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 96 94 94 88 88 88 77 77 77 77 77 77 70 70 70 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 95 93 93 89 89 89 79 79 79 79 79 79 72 72 72 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 94 92 92 91 91 91 82 82 82 81 81 81 76 76 76 71 71 71 66 66 66 61 61 61 57 57 57 54 54 54 94 91 91 93 91 91 85 85 85 84 84 84 80 80 80 76 76 76 71 71 71 68 68 68 63 63 63 60 60 60 5 105 79 64 98 79 64 83 79 64 81 79 64 73 73 64 67 67 64 61 61 61 57 57 57 54 54 54 51 51 51 10 109 81 65 96 81 65 81 81 65 80 80 65 70 70 65 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 108 80 65 95 80 65 80 80 65 76 76 65 67 67 65 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 106 79 65 95 79 65 80 79 65 76 76 65 67 67 65 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 120 25 104 79 64 95 79 64 81 79 64 77 77 64 68 68 64 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 93 91 91 87 87 87 76 76 76 76 76 76 69 69 69 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 92 90 90 88 88 88 78 78 78 77 77 77 71 71 71 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 92 89 89 89 89 89 81 81 81 80 80 80 75 75 75 70 70 70 66 66 66 61 61 61 57 57 57 54 54 54 91 88 88 91 88 88 83 83 83 83 83 83 79 79 79 75 75 75 70 70 70 68 68 68 63 63 63 60 60 60 5 97 73 59 97 73 59 83 73 59 81 73 59 73 73 59 67 67 59 61 61 59 57 57 57 54 54 54 51 51 51 10 101 75 60 95 75 60 80 75 60 79 75 60 70 70 60 63 63 60 57 57 57 54 54 54 51 51 51 47 47 47 15 100 74 60 94 74 60 79 74 60 76 74 60 67 67 60 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 98 73 60 94 73 60 79 73 60 76 73 60 67 67 60 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 130 25 97 73 59 94 73 59 80 73 59 77 73 59 68 68 59 61 61 59 56 56 56 52 52 52 48 48 48 46 46 46 30 88 84 84 83 83 83 74 74 74 73 73 73 68 68 68 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 87 84 84 84 84 84 76 76 76 75 75 75 70 70 70 66 66 66 61 61 61 56 56 56 53 53 53 51 51 51 40 87 83 83 86 83 83 78 78 78 77 77 77 73 73 73 69 69 69 64 64 64 61 61 61 57 57 57 54 54 54 86 82 82 86 82 82 80 80 80 80 80 80 76 76 76 72 72 72 69 69 69 66 66 66 63 63 63 60 60 60 5 90 68 55 90 68 55 83 68 55 81 68 55 73 68 55 67 67 55 61 61 55 57 57 55 54 54 54 51 51 51 10 94 69 56 93 69 56 79 69 56 77 69 56 70 69 56 63 63 56 57 57 56 54 54 54 51 51 51 47 47 47-- 15 93 69 56 92 69 56 78 69 56 76 69 56 67 67 56 60 60 56 54 54 54 51 51 51 47 47 47 45 45 45 20 92 68 56 91 68 56 78 68 56 76 68 56 67 67 56 60 60 56 55 55 55 51 51 51 47 47 47 45 45 45 140 25 91 68 55 91 68 55 79 68 55 77 68 55 68 68 55 61 61 55 56 56 55 52 52 52 48 48 48 46 46 46 30 83 79 79 80 79 79 72 72 72 71 71 71 67 67 67 62 62 62 57 57 57 54 54 54 51 51 51 47 47 47 35 83 78 78 81 78 78 73 73 73 73 73 73 69 69 69 64 64 64 61 61 61 56 56 56 53 53 53 51 51 51 40 82 78 78 82 78 78 75 75 75 75 75 75 71 71 71 67 67 67 63 63 63 61 61 61 57 57 57 54 54 54 82 77 77 82 77 77 78 77 77 77 77 77 74 74 74 71 71 71 68 68 68 64 64 64 62 62 62 60 60 60 5 84 63 51 84 63 51 83 63 51 81 63 51 73 63 51 67 63 51 61 61 51 57 57 51 54 54 51 51 51 51 10 88 65 52 88 65 52 77 65 52 76 65 52 70 65 52 63 63 52 57 57 52 54 54 52 51 51 51 47 47 47-- 15 87 64 52 87 64 52 76 64 52 75 64 52 67 64 52 60 60 52 54 54 52 51 51 51 47 47 47 45 45 45 20 86 64 52 86 64 52 76 64 52 75 64 52 67 64 52 60 60 52 55 55 52 51 51 51 47 47 47 45 45 45 150 25 85 64 52 85 64 52 77 64 52 76 64 52 68 64 52 61 61 52 56 56 52 52 52 52 48 48 48 46 46 46 30 79 74 74 77 74 74 70 70 70 69 69 69 65 65 65 61 61 61 57 57 57 54 54 54 51 51 51 47 47 47 35 78 74 74 78 74 74 71 71 71 71 71 71 67 67 67 63 63 63 60 60 60 56 56 56 53 53 53 51 51 51 40 78 73 73 78 73 73 73 73 73 72 72 72 69 69 69 66 66 66 62 62 62 60 60 60 56 56 56 54 54 54 78 73 73 78 73 73 75 73 73 74 73 73 71 71 71 69 69 69 66 66 66 63 63 63 61 61 61 59 59 59 5 79 59 48 79 59 48 79 59 48 79 59 48 73 59 48 67 59 48 61 59 48 57 57 48 54 54 48 51 51 48 10 82 61 49 82 61 49 75 61 49 74 61 49 69 61 49 63 61 49 57 57 49 54 54 49 51 51 49 47 47 47 15 82 60 49 82 60 49 75 60 49 74 60 49 67 60 49 60 60 49 54 54 49 51 51 49 47 47 47 45 45 45 20 81 60 49 81 60 49 75 60 49 74 60 49 67 60 49 60 60 49 55 55 49 51 51 49 47 47 47 45 45 45 160 25 80 60 49 80 60 49 76 60 49 75 60 49 68 60 49 61 60 49 56 56 49 52 52 49 48 48 48 46 46 46 30 75 70 70 74 70 70 68 68 68 67 67 67 63 63 63 60 60 60 56 56 56 53 53 53 51 51 51 47 47 47 35 74 69 69 74 69 69 69 69 69 68 68 68 65 65 65 62 62 62 59 59 59 55 55 55 53 53 53 51 51 51 40 74 69 69 74 69 69 70 69 69 70 69 69 67 67 67 64 64 64 61 61 61 59 59 59 56 56 56 54 54 54 45 74 68 68 74 68 68 72 68 68 72 68 68 69 68 68 67 67 67 64 64 64 62 62 62 60 60 60 57 57 57 5 74 56 45 74 56 45 74 56 45 74 56 45 73 56 45 67 56 45 61 56 45 57 56 45 54 54 45 51 51 45 10 78 57 46 78 57 46 74 57 46 73 57 46 67 57 46 63 57 46 57 57 46 54 54 46 51 51 46 47 47 46 15 77 57 46 77 57 46 73 57 46 72 57 46 66 57 46 60 57 46 54 54 46 51 51 46 47 47 46 45 45 45 20 76 57 46 76 57 46 73 57 46 72 57 46 66 57 46 60 57 46 55 55 46 51 51 46 47 47 46 45 45 45 170 25 76 56 46 76 56 46 74 56 46 73 56 46 67 56 46 61 56 46 56 56 46 52 52 46 48 48 46 46 30 71 66 66 71 66 66 66 66 66 65 65 65 62 62 62 59 59 59 55 55 55 53 53 53 49 49 49 47 35 71 66 66 71 66 66 67 66 66 66 66 66 63 63 63 60 60 60 57 57 57 54 54 54 52 52 52 49 40 71 65 65 71 65 65 68 65 65 68 65 65 65 65 65 62 62 62 60 60 60 57 57 57 55 55 55 53 45 70 65 65 70 65 65 70 65 65 69 65 65 67 65 65 65 65 65 63 63 63 61 61 61 59 59 59 56 CRY 5 70 53 42 70 53 42 70 53 42 70 53 42 70 53 42 67 53 42 61 53 42 57 53 42 54 53 42 51 10 73 54 44 73 54 44 72 54 44 71 54 44 66 54 44 62 54 44 57 54 44 54 54 44 51 51 44 47 15 73 54 44 73 54 44 72 54 44 71 54 44 66 54 44 60 54 44 54 54 44 51 51 44 47 47 44 45 20 72 54 44 72 54 44 72 54 44 71 54 44 66L61 44 60L61 44 55 54 44 51 51 44 47 47 44 45 180 25 72 53 44 72 53 44 72 53 44 71 53 44 66 44 61 44 56 53 44 52 52 44 48 48 44 46 30 68 63 63 68 63 63 64 63 63 63 63 63 60 60 57 57 54 54 54 52 52 52 49 49 49 47 35 68 62 62 68 62 62 65 62 62 64 62 62 61 61 59 59 56 56 56 54 54 54 52 52 52 49 40 67 62 62 67 62 62 66 62 62 66 62 62 63 62 61 61 59 59 59 56 56 56 54 54 54 52 45 67 62 62 67 62 62 67 62 62 67 62 62 65 62 63 62 61 61 61 59 59 59 57 57 57 55 Rail:Flush 00 Mount System Span TableXR1(inches) Portrait Installation (Maximum Module Length 67.5") Exposure D wind Roof Ground Snow: 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf Speed (mph) Slope (d egs.) Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 5 106 80 64 98 80 64 83 80 64 81 80 64 73 73 64 67 67 64 61 61 61 57 57 57 54 54 54 51 51 51 10 110 81 65 96 81 65 81 81 65 80 80 65 70 70 65 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 15 108 80 65 95 80 65 80 80 65 76 76 65 67 67 65 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 106 79 65 95 79 65 80 79 65 76 76 65 67 67 65 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 110 25 105 79 64 95 79 64 81 79 64 77 77 64 68 68 64 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 30 93 91 91 87 87 87 76 76 76 76 76 76 69 69 69 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 92 90 90 88 88 88 78 78 78 77 77 77 71 71 71 67 67 67 61 61 61 56 56 56 53 53 53 51 51 51 40 92 89 89 89 89 89 81 81 81 80 80 80 75 75 75 70 70 70 66 66 66 61 61 61 57 57 57 54 54 54 92 88 88 91 88 88 83 83 83 83 83 83 79 79 79 75 75 75 71 71 71 68 68 68 63 63 63 60 60 60 5 101 76 61 98 76 61 83 76 61 81 76 61 73 73 61 67 67 61 61 61 61 57 57 57 54 54 54 51 51 51 105 77 63 96 77 63 81 77 63 80 77 63 70 70 63 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 103 77 62 95 77 62 80 77 62 76 76 62 67 67 62 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 102 76 62 95 76 62 80 76 62 76 76 62 67 67 62 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 11$100 75 62 95 75 62 81 75 62 77 75 62 68 68 62 61 61 61 56 56 56 52 52 52 48 48 48 46 46 46 b10 90 87 87 85 85 85 75 75 75 74 74 74 69 69 69 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 90 86 86 86 86 86 77 77 77 76 76 76 71 71 71 66 66 66 61 61 61 56 56 56 53 53 53 51 51 51 89 86 86 87 86 86 79 79 79 79 79 79 74 74 74 69 69 69 66 66 66 61 61 61 57 57 57 54 54 54 89 85 85 89 85 85 82 82 82 81 81 81 77 77 77 74 74 74 70 70 70 67 67 67 63 63 63 60 60 60 5 97 73 59 97 73 59 83 73 59 81 73 59 73 73 59 67 67 59 61 61 59 57 57 57 54 54 54 51 51 51 10 101 74 60 95 74 60 80 74 60 79 74 60 70 70 60 63 63 60 57 57 57 54 54 54 51 51 51 47 47 47 15 99 74 60 94 74 60 79 74 60 76 74 60 67 67 60 60 60 60 54 54 54 51 51 51 47 47 47 45 45 45 20 98 73 60 94 73 60 79 73 60 76 73 60 67 67 60 60 60 60 55 55 55 51 51 51 47 47 47 45 45 45 120 25 97 73 59 94 73 59 80 73 59 77 73 59 68 68 59 61 61 59 56 56 56 52 52 52 48 48 48 46 46 46 30 87 84 84 83 83 83 74 74 74 73 73 73 68 68 68 63 63 63 57 57 57 54 54 54 51 51 51 47 47 47 35 87 83 83 84 83 83 76 76 76 75 75 75 70 70 70 66 66 66 61 61 61 56 56 56 53 53 53 51 51 51 40 86 83 83 85 83 83 78 78 78 77 77 77 73 73 73 69 69 69 64 64 64 61 61 61 57 57 57 54 54 54 86 82 82 86 82 82 80 80 80 80 80 80 76 76 76 72 72 72 69 69 69 66 66 66 63 63 63 60 60 60 5 89 67 54 89 67 54 83 67 54 81 67 54 73 67 54 67 67 54 61 61 54 57 57 54 54 54 54 51 51 51 10 93 69 56 92 69 56 78 69 56 77 69 56 70 69 56 63 63 56 57 57 56 54 54 54 51 51 51 47 47 47 15 92 68 55 91 68 55 78 68 55 76 68 55 67 67 55 60 60 55 54 54 54 51 51 51 47 47 47 45 45 45 20 91 68 55 91 68 55 78 68 55 76 68 55 67 67 55 60 60 55 55 55 55 51 51 51 47 47 47 45 45 45 130 25 90 67 55 90 67 55 79 67 55 77 67 55 68 67 55 61 61 55 56 56 55 52 52 52 48 48 48 46 46 46 30 82 78 78 80 78 78 72 72 72 71 71 71 67 67 67 62 62 62 57 57 57 54 54 54 51 51 51 47 47 47 35 82 78 78 81 78 78 73 73 73 72 72 72 68 68 68 64 64 64 60 60 60 56 56 56 53 53 53 51 51 51 40 82 77 77 82 77 77 75 75 75 74 74 74 71 71 71 67 67 67 63 63 63 60 60 60 57 57 57 54 54 54 81 76 76 81 76 76 77 76 76 77 76 76 73 73 73 71 71 71 68 68 68 64 64 64 62 62 62 60 60 60 5 83 62 50 83 62 50 83 62 50 81 62 50 73 62 50 67 62 50 61 61 50 57 57 50 54 54 50 51 51 50 10 86 64 52 86 64 52 77 64 52 76 64 52 70 64 52 63 63 52 57 57 52 54 54 52 51 51 51 47 47 47 15 86 63 52 86 63 52 76 63 52 75 63 52 67 63 52 60 60 52 54 54 52 51 51 51 47 47 47 45 45 45 20 85 63 51 85 63 51 76 63 51 75 63 51 67 63 51 60 60 51 55 55 51 51 51 51 47 47 47 45 45 47-- 140 25 84 63 51 84 63 51 77 63 51 75 63 51 68 63 51 61 61 51 56 56 51 52 52 51 48 48 48 46 46 46 30 78 73 73 77 73 73 69 69 69 69 69 69 64 64 64 61 61 61 56 56 56 54 54 54 51 51 51 47 47 47 35 77 73 73 77 73 73 71 71 71 70 70 70 66 66 66 62 62 62 59 59 59 56 56 56 53 53 53 51 51 51 40 77 72 72 77 72 72 72 72 72 72 72 72 68 68 68 65 65 65 62 62 62 59 59 59 56 56 56 54 54 54 45 77 72 72 77 72 72 74 72 72 74 72 72 71 71 71 68 68 68 66 66 66 63 63 63 61 61 61 59 59 59 5 77 58 47 77 58 47 77 58 47 77 58 47 73 58 47 67 58 47 61 58 47 57 57 47 54 54 47 51 51 47 10 81 60 48 81 60 48 75 60 48 74 60 48 68 60 48 63 60 48 57 57 48 54 54 48 51 51 48 47 47 47 15 80 59 48 80 59 48 74 59 48 73 59 48 67 59 48 60 59 48 54 54 48 51 51 48 47 47 47 45 45 45 20 79 59 48 79 59 48 74 59 48 73 59 48 67 59 48 60 59 48 55 55 48 51 51 48 47 47 47 45 45 45 1$0 25 79 59 48 79 59 48 75 59 48 74 59 48 68 59 48 61 59 48 56 56 48 52 52 48 48 48 48 46 46 46 30 74 69 69 74 69 69 67 67 67 66 66 66 63 63 63 59 59 59 56 56 56 53 53 53 51 51 51 47 47 47 35 73 68 68 73 68 68 68 68 68 68 68 68 64 64 64 61 61 61 57 57 57 55 55 55 53 53 53 51 51 51 40 73 68 68 73 68 68 70 68 68 69 68 68 66 66 66 64 64 64 61 61 61 57 57 57 55 55 55 53 53 53 45 73 67 67 73 67 67 71 67 67 71 67 67 68 67 67 66 66 66 64 64 64 62 62 62 60 60 60 57 57 5T- 5 73 55 44 73 55 44 73 55 44 73 55 44 73 55 44 67 55 44 61 55 44 57 55 44 54 54 44 51 51 44 10 76 56 45 76 56 45 73 56 45 72 56 45 67 56 45 63 56 45 57 56 45 54 54 45 51 51 45 47 47 45 15 75 56 45 75 56 45 73 56 45 72 56 45 66 56 45 60 56 45 54 54 45 51 51 45 47 47 45 45 45 45 20 75 55 45 75 55 45 73 55 45 72 55 45 66 55 45 60 55 45 55 55 45 51 51 45 47 47 45 45 45 45 160 25 74 55 45 74 55 45 73 55 45 72 55 45 67 55 45 61 55 45 56 55 45 52 52 45 48 48 45 46 46 45 30 70 65 65 70 65 65 65 65 65 64 64 64 61 61 61 57 57 57 55 55 55 52 52 52 49 49 49 47 47 47 35 70 64 64 70 64 64 66 64 64 65 64 64 62 62 62 60 60 60 56 56 56 54 54 54 52 52 52 49 49 49 40 69 64 64 69 64 64 67 64 64 67 64 64 64 64 64 62 62 62 60 60 60 56 56 56 54 54 54 53 53 53 69 64 64 69 64 64 69 64 64 68 64 64 66 64 64 64 64 64 62 62 62 60 60 60 57 57 57 56 56 56 5 68 51 41 68 51 41 68 51 41 68 51 41 68 51 41 67 51 41 61 51 41 57 51 41 54 51 41 51 51 41 10 72 53 43 72 53 43 71 53 43 71 53 43 66 53 43 62 53 43J60 53 43 54 53 43 51 51 43 47 47 43 15 71 52 43 71 52 43 71 52 43 70 52 43 64 52 43 60 52 43 52 43 51 51 43 47 47 43 45 45 43 20 71 52 43 71 52 43 71 52 43 70 52 43 64 52 43 60 52 43 52 43 51 51 43 47 47 43 45 45 43 170 25 70 52 42 70 52 42 70 52 42 70 52 42 66 52 42 61 52 42 52 42 52 52 42 48 48 42 46 46 42 30 66 61 61 66 61 61 63 61 61 62 61 61 59 59 59 56 56 56 54 54 51 51 51 48 48 48 47 47 47 35 66 61 61 66 61 61 64 61 61 63 61 61 61 61 61 58 58 58 55 55 53 53 53 51 51 51 48 "O 40 66 60 60 66 60 60 65 60 60 65 60 60 62 60 60 60 60 60 57 57 55 55 55 53 53 53 52 65 60 60 65 60 60 65 60 60 65 60 60 64 60 60 62 60 60 60 60 59 59 59 56 56 56 55 5 65 68 49 50 40 65 68 49 50 40 65 68 49 50 40 65 68 49 50 40 65 64 49 50 40 65 61 49 50 40 49 50 40 57 54 49 50 40 54 51 49 50 40 51 47 CRYIty15 67 50 40 67 50 40 67 50 40 67 50 40 63 50 40 59 50 40 50 40 51 50 40 47 47 40 45 20 67 49 40 67 49 40 67 49 40 67 49 40 63 49 40 59 49 40 55 49 40 51 49 40 47 47 40 45 1$0 25 66 49 40 66 49 40 66 49 40 66 49 40 64 49 40 60 49 40 56 49 40 52 49 40 48 48 40 46 8� 30 63 58 58 63 58 58 61 58 58 60 58 58 58 58 58 55 55 55 53 53 53 51 51 51 48 48 48 46 35 63 58 58 63 58 58 62 58 58 61 58 58 59 58 58 56 56 56 54 54 54 52 52 52 49 49 49 48 40 62 57 57 62 57 57 62 57 57 62 57 57 60 57 57 58 1 57 57 56 56 56 54 54 54 53 53 53 51 62 57 57 62 57 57 62 57 57 62 57 57 62 57 57 60 57 57 58 57 57 57 57 57 55 55 55 54 Note: The regions in the gray shade denote an additional installation requirement on UFO middle clamps. Please referto Note 11 on Page 2 for details. Flush Mount System Span Table (inches) Portrait Installation (Maximum Module Length 78.5") Exposure B Wind Roof Ground Snow: 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf Speed (mph) Slope (deg5.) Zone Zone2 Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone 5 110 97 78 92 92 78 JJ JJ JJ 76 76 76 68 68 68 62 62 62 57 57 57 53 53 53 50 50 50 47 47 47 10 108 97 78 90 90 78 75 75 75 74 74 74 66 66 66 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 15 107 96 78 89 89 78 75 75 75 70 70 70 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 105 90 JJ 88 88 JJ 75 75 75 70 70 70 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 110 25 104 93 76 89 89 76 75 75 75 71 71 71 62 62 62 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 102 102 102 89 89 89 JJ JJ JJ 74 74 74 60 60 60 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 35 101 101 101 91 91 91 79 79 79 JJ JJ JJ 68 68 68 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 101 101 101 92 92 92 82 82 82 80 80 80 72 72 72 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 45 100 100 100 95 95 95 85 85 85 80 80 80 78 78 78 R R R 67 67 67 62 62 62 59 59 59 56 56 56 5 110 93 75 92 92 75 JJ JJ 75 76 76 75 68 68 68 62 62 62 57 57 57 53 53 53 50 50 50 47 47 47 10 108 93 75 90 90 75 75 75 75 74 74 74 66 66 66 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 15 107 92 74 89 89 74 75 75 74 70 70 70 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 105 91 74 88 88 74 75 75 74 70 70 70 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 115 25 104 89 73 89 89 73 75 75 73 71 71 71 62 62 62 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 100 100 100 88 88 88 76 76 76 74 74 74 60 60 60 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 35 99 99 99 89 89 89 78 78 78 JJ JJ JJ 68 68 68 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 98 98 98 91 91 91 81 81 81 80 80 80 72 72 72 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 45 97 97 97 93 1 93 93 80 80 80 83 83 83 1 78 78 78 1 72 72 72 67 67 67 62 62 1 62 59 59 59 56 56 56 5 110 88 71 92 88 71 JJ JJ 71 76 76 71 68 68 68 62 62 62 57 57 57 53 53 53 50 50 50 47 47 47 10 108 89 72 90 89 72 75 75 72 74 74 72 66 66 66 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 15 107 88 71 89 88 71 75 75 71 70 70 70 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 105 87 71 88 87 71 75 75 71 70 70 70 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 120 25 100 86 70 89 86 70 75 75 70 71 71 70 62 62 62 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 97 97 97 86 86 86 75 75 75 74 74 74 60 60 60 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 35 96 96 96 88 88 88 JJ JJ JJ 76 76 76 68 68 68 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 96 95 95 89 89 89 80 80 80 79 79 79 72 72 72 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 45 95 90 90 91 91 91 83 83 83 82 82 82 JJ JJ JJ 72 72 72 67 67 67 62 62 62 59 59 59 56 56 56 5 108 81 65 92 81 65 JJ JJ 65 76 76 65 68 68 65 62 62 62 57 57 57 53 53 53 50 50 50 47 47 47 10 108 82 66 90 82 66 75 75 66 74 74 66 66 66 66 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 15 107 81 66 89 81 66 75 75 66 70 70 66 62 1 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 105 81 65 88 81 65 75 75 65 70 70 65 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 130 25 100 80 65 89 80 65 75 75 65 71 71 65 62 62 62 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 92 92 92 80 80 80 73 73 73 72 72 72 60 60 60 59 59 59 54 54 54 49 49 49 47 47 47 140 40 40 35 91 90 90 85 85 85 75 75 75 74 74 74 68 68 68 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 91 89 89 86 86 86 JJ JJ JJ JJ JJ JJ 71 71 71 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 45 90 88 88 88 88 88 80 80 80 80 80 80 75 75 75 71 71 71 67 67 67 62 62 62 59 59 59 56 56 56 5 100 75 61 92 75 61 JJ 75 61 76 75 61 68 68 61 62 62 60 57 57 57 53 53 53 50 50 50 47 47 47 10 100 76 62 90 76 62 75 75 62 74 74 62 66 66 62 59 59 59 54 54 54 49 49 49 47 47 47 40 40 37-- 15 102 76 61 89 76 61 75 75 61 70 70 61 62 62 61 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 100 75 61 88 75 61 75 75 61 70 70 61 62 62 61 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 140 25 98 74 61 89 74 61 1 75 74 61 71 71 61 62 62 61 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 87 86 86 81 81 81 71 71 71 70 70 70 60 60 60 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 35 87 85 85 82 82 82 73 73 73 72 72 72 67 67 67 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 86 80 80 83 83 83 75 75 75 75 75 75 70 70 70 66 66 66 61 61 61 57 57 57 54 54 54 51 1 51 51 45 86 83 83 85 83 83 78 78 78 JJ JJ JJ 74 74 74 70 70 70 66 66 66 62 62 62 59 59 59 56 56 56 5 93 70 56 92 70 56 JJ 70 56 76 70 56 68 68 56 62 62 56 57 57 56 53 53 53 50 50 50 47 47 47 10 97 71 58 90 71 58 75 71 58 74 71 58 66 66 58 59 59 58 54 54 54 49 49 49 47 47 47 40 40 40 15 95 71 57 89 71 57 74 71 57 70 70 57 62 62 57 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 90 70 57 88 70 57 74 70 57 70 70 57 62 62 57 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 150 25 92 70 57 89 70 57 75 70 57 71 70 57 62 62 57 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 83 81 81 79 79 79 70 70 70 69 69 69 63 63 63 59 59 59 54 54 54 49 49 49 47 47 47 40 40 40 35 83 80 80 79 79 79 71 71 71 71 71 71 66 66 66 61 61 61 56 56 56 53 53 53 49 49 49 47 47 47 40 82 79 79 81 79 79 73 73 73 73 73 73 69 69 69 64 64 64 61 61 61 57 57 57 54 54 54 51 51 51 45 82 78 78 82 78 78 76 76 76 75 75 75 72 72 72 68 68 68 64 64 64 62 62 62 59 59 59 56 56 56 5 87 66 53 87 66 53 JJ 66 53 76 66 53 68 66 53 62 62 53 57 57 53 53 53 53 50 50 50 1 47 1 47 47 10 91 67 50 88 67 50 74 67 50 73 67 50 66 66 50 59 59 54 54 54 54 49 49 49 47 47 47 40 40 40 15 89 66 50 87 66 50 73 66 50 70 66 50 62 62 50 55 55 54 51 51 51 47 47 47 44 44 44 41 41 41 20 88 66 50 86 66 50 73 66 50 70 66 50 62 62 50 55 55 54 51 51 51 47 47 47 44 44 44 41 41 41 160 25 87 65 53 87 65 53 74 65 53 71 65 53 62 62 53 56 56 53 52 52 52 48 48 48 45 45 45 43 43 43 30 79 76 76 76 76 76 68 68 68 67 67 67 62 62 62 57 57 57 54 54 54 49 49 49 47 47 47 40 40 40 35 79 75 75 JJ 75 75 69 69 69 69 69 69 60 60 60 60 60 60 56 56 56 53 53 53 1 49 49 49 47 47 47 40 79 75 75 78 75 75 71 71 71 71 71 71 67 67 67 63 63 1 63 60 60 60 56 56 56 54 54 54 51 51 51 45 78 74 74 78 74 74 73 73 73 73 73 73 70 70 70 67 1 67 67 63 63 63 61 61 61 59 59 59 56 56 56 5 82 62 50 82 62 50 JJ 62 50 76 62 50 68 1 62 50 62 62 50 57 57 50 53 53 50 50 50 50 47 47 47 10 85 63 51 85 63 51 73 63 51 72 63 51 66 63 51 59 59 51 54 54 51 49 49 49 47 47 47 40 40 40 15 80 63 51 80 63 51 72 63 51 70 63 51 62 62 51 55 55 51 51 51 51 47 47 47 44 44 44 41 41 41 20 83 62 51 83 62 51 72 62 51 70 62 51 62 62 51 55 55 51 51 51 51 47 47 47 44 44 44 41 41 41 170 25 82 62 50 82 62 50 73 62 50 71 62 50 62 62 50 56 56 50 52 52 50 48 48 48 45 45 45 43 43 43 30 76 72 72 74 72 72 66 66 66 66 66 66 61 61 61 57 57 57 54 54 54 49 49 49 47 47 47 40 M 35 JS 71 71 74 71 71 67 67 67 67 67 67 63 63 63 59 59 59 55 55 55 53 53 53 49 49 49 47 4: 40 75 71 71 75 71 71 69 69 69 69 69 69 65 65 65 62 62 62 59 59 59 56 56 56 53 53 53 51 5[ 45 75 70 70 75 70 70 71 70 70 71 70 70 68 68 68 65 65 65 62 62 62 60 60 60 57 57 57 55 5. 5 JJ 58 47 JJ 58 47 JJ 58 47 76 58 47 68 58 47 62 58 47 57 57 47 53 53 47 50 50 47 47 41 a 10 81 60 48 81 60 48 71 60 48 70 60 48 65 60 48 59 59 48 54 54 48 49 49 48 47 47 47 40 M 15 80 59 48 80 59 48 71 59 48 69 59 48 62 59 48 55 55 48 51 51 48 47 47 47 44 44 44 41 4[ 20 79 59 48 79 59 48 71 59 48 69 59 48 62 59 48 55 55 48 51 51 48 47 47 47 44 44 44 41 4[ 180 25 78 59 48 78 59 48 71 59 48 JO 59 48 62 59 48 56 56 48 52 52 48 48 48 48 45 45 45 43 4f 30 72 68 68 71 68 68 60 60 60 60 60 60 60 60 60 56 56 56 53 53 53 49 49 49 47 47 47 40 M •M•w^I^•''�'1• 35 J2 68 68 J2 68 68 66 66 66 65 65 65 62 62 62 59 59 59 55 55 55 52 52 52 49 49 49 47 4: 40 72 67 67 72 67 67 67 67 67 67 67 j 67 60 60 60 61 61 61 57 57 57 55 55 55 53 53 53 51 5[ 45 72 67 67 J2 67 67 69 67 67 69 67 67 66 66 66 64 64 64 61 61 61 59 59 59 56 56 56 50 S Rail:Flush Mount System Span Table (inches) Portrait Installation (Maximum Module Length 78.5") Exposure C Wind Roof Ground Snow: 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf Speed (mph) Slope (d eg5.) Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone 5 107 81 65 92 81 65 JJ JJ 65 76 76 65 68 68 65 62 62 62 57 57 57 53 53 53 50 50 50 47 47 47 10 108 82 66 90 82 66 75 75 66 74 74 66 66 66 66 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 15 107 81 66 89 81 66 75 75 66 70 70 66 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 105 80 65 88 80 65 75 75 65 70 70 65 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 110 25 104 80 65 89 80 65 75 75 65 71 71 65 62 62 62 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 92 91 91 84 84 84 73 73 73 72 72 72 64 64 64 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 35 91 90 90 85 85 85 75 75 75 74 74 74 68 68 68 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 91 89 89 86 86 86 JJ JJ JJ JJ JJ JJ 71 71 71 67 67 67 61 61 61 57 57 57 54 54 54 51 51 51 45 90 88 88 1 88 88 88 80 80 80 80 80 80 75 75 75 71 71 71 67 67 67 62 62 62 59 59 59 56 56 56 5 103 78 63 92 78 63 JJ JJ 63 76 76 63 68 68 63 62 62 62 57 57 57 53 53 53 50 50 50 47 47 47 10 1O7 1 79 63 90 79 63 75 75 63 74 74 63 66 66 63 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 15 105 78 63 89 78 63 75 75 63 70 70 63 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 103 JJ 63 88 JJ 63 75 75 63 70 70 63 62 62 62 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 115 25 101 76 62 89 76 62 75 75 62 71 71 62 62 62 62 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 89 88 88 82 82 82 72 72 72 71 71 71 64 64 64 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 35 89 87 87 83 83 83 74 74 74 73 73 73 68 68 68 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 88 86 86 85 1 85 85 76 76 76 1 75 75 JS 1 70 70 70 1 66 66 66 61 61 61 57 57 57 54 54 54 51 1 51 51 45 88 85 85 86 85 85 79 79 79 78 78 78 74 74 74 70 70 70 67 67 67 62 62 62 59 59 59 56 56 56 5 98 74 60 92 74 60 JJ 74 60 76 74 60 68 68 60 62 62 60 57 57 57 53 53 53 50 50 50 47 47 47 10 102 75 61 90 75 61 75 75 61 74 74 61 66 66 61 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 15 100 75 60 89 75 60 75 75 60 70 70 60 62 62 60 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 99 1 74 60 88 74 60 75 74 60 70 70 60 62 62 60 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 120 25 97 73 60 89 73 60 75 73 60 71 71 60 62 62 60 56 56 56 52 52 52 48 1 48 1 48 45 1 45 45 43 43 43 30 87 85 85 81 81 81 71 71 71 70 70 70 64 64 64 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 35 86 84 84 82 82 82 73 73 73 72 72 72 67 67 67 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 86 83 83 83 83 83 75 75 75 74 74 74 70 70 70 66 66 66 61 61 61 57 57 57 54 54 54 51 51 51 45 85 82 82 84 82 82 78 78 78 JJ JJ JJ 73 73 73 69 69 69 66 66 66 62 62 62 59 59 59 56 56 56 5 91 68 55 1 91 1 68 55 1 JJ 68 55 1 76 68 55 68 68 55 62 62 55 57 57 55 53 53 53 50 50 1 50 47 47 47 10 94 70 56 89 70 56 75 70 56 74 70 56 66 66 56 59 59 56 54 54 54 49 49 49 47 47 47 44 44 44 15 93 69 56 88 69 56 74 69 56 70 69 56 62 62 56 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 92 68 56 88 68 56 74 68 56 70 68 56 62 62 56 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 130 25 90 68 55 88 68 55 75 68 55 71 68 55 62 62 55 56 56 1 55 52 52 52 48 48 48 45 45 45 43 43 43 30 82 1 79 79 78 78 78 69 69 69 68 68 68 63 63 63 59 59 59 54 54 54 49 49 49 1 47 47 47 44 44 44 35 81 78 78 78 78 78 70 70 70 70 70 70 66 66 66 61 61 61 56 56 56 53 11 53 53 49 49 49 47 47 47 40 81 JJ JJ 80 JJ JJ 72 72 72 72 72 72 68 68 68 63 63 63 60 60 60 57 57 57 54 54 54 51 51 51 45 80 76 76 80 76 76 75 75 75 74 74 74 71 71 71 68 68 68 64 64 64 61 61 61 59 59 59 56 56 56 5 84 63 51 84 63 51 JJ 63 51 76 63 51 68 63 51 62 62 51 57 57 51 53 53 51 50 50 50 47 47 47-- 10 88 65 52 87 65 52 73 65 52 72 65 52 66 65 52 59 59 52 54 54 52 49 49 49 47 47 47 44 44 44 15 87 64 52 86 64 52 72 64 52 70 64 52 62 62 52 55 55 52 51 51 51 47 47 47 44 44 44 41 41 41 20 85 64 52 85 64 52 73 64 52 70 64 52 62 1 62 52 55 55 52 51 51 51 47 47 47 44 44 44 41 41 41 140 25 84 63 52 84 63 52 73 63 52 71 63 52 62 62 52 56 56 52 52 52 52 48 48 48 45 45 45 43 43 43 30 JJ 74 74 75 74 74 67 67 67 66 66 66 62 62 62 57 57 57 54 54 54 49 49 49 47 47 47 44 44 44 35 JJ 73 73 75 73 73 68 68 68 68 68 68 63 63 63 60 1 60 60 56 56 56 53 53 53 49 49 49 47 47 47 40 77 1 72 72 76 72 72 70 70 70 70 70 70 66 66 66 62 62 62 59 59 59 56 56 56 54 54 54 51 51 51 45 76 72 72 76 72 72 72 72 72 72 72 72 69 69 69 66 66 66 63 63 63 60 60 60 57 57 57 55 55 55 5 78 59 48 78 59 48 JJ 59 48 76 59 48 68 59 48 62 59 48 57 57 48 53 53 48 50 50 47 47 47 47 10 82 60 49 82 60 49 72 60 49 71 60 49 65 60 49 59 59 49 54 54 49 49 49 49 47 47 47 44 44 44 15 81 60 49 81 60 49 71 60 49 70 60 49 62 60 49 55 55 49 51 51 49 47 47 47 44 44 44 41 41 41 20 80 60 48 80 60 48 71 60 48 69 60 48 62 60 48 55 55 48 51 51 48 47 47 47 44 44 44 41 41 41 150 25 J9 59 48 79 59 48 72 59 48 70 59 48 62 59 48 56 56 48 52 52 48 48 48 48 45 45 45 43 43 43 30 73 69 69 72 69 69 65 65 65 64 64 64 1 60 60 60 56 56 56 53 53 53 49 49 49 47 47 47 44 44 44 35 73 68 68 73 68 68 66 66 66 66 66 66 62 62 62 59 59 59 55 55 55 52 52 52 49 49 49 47 47 47 40 73 68 68 73 68 68 68 68 68 67 67 67 64 64 64 61 61 1 61 57 57 57 55 55 55 53 53 53 51 51 51 45 72 68 68 72 68 68 70 68 68 69 68 68 66 66 66 64 64 64 61 61 61 59 59 59 56 56 56 54 54 54 5 74 55 45 74 55 45 74 55 45 74 55 45 68 55 45 62 55 45 57 1 55 45 53 1 53 45 50 50 45 47 47 45 10 77 57 46 77 57 46 70 57 46 69 57 46 64 57 46 59 57 46 54 54 46 49 49 46 47 47 46 44 44 44 15 76 56 46 76 56 46 70 56 46 69 56 46 62 56 46 55 55 46 51 51 46 47 47 46 44 44 44 41 41 41 20 75 56 46 75 56 46 70 56 46 68 56 46 62 56 46 55 55 46 51 51 46 47 47 46 44 44 44 41 41 41 160 25 75 56 45 75 56 45 70 56 45 69 56 45 62 56 45 56 56 45 52 52 45 48 48 45 45 45 45 43 43 43 30 70 1 65 65 69 1 65 65 63 1 63 63 62 62 62 59 59 59 55 55 55 52 52 52 49 49 49 47 47 47 44 44 37-- 35 69 65 65 69 65 65 64 64 64 64 64 64 60 60 60 57 57 57 54 54 54 52 52 52 49 49 49 47 47 47 40 69 64 64 69 64 64 66 64 64 65 64 64 1 62 62 1 62 60 60 60 56 56 56 54 54 54 52 52 52 49 49 49 45 69 64 64 69 64 64 67 64 64 67 64 64 64 64 64 62 62 62 60 60 60 57 57 57 55 55 55 53 53 53 5 69 52 42 69 52 42 69 52 42 69 52 42 68 52 42 62 1 52 42 57 52 42 53 52 42 50 50 42 47 47 42 10 72 53 43 72 53 43 69 53 43 68 53 43 63 53 43 59 53 1 43 54 53 1 43 49 49 43 47 47 43 44 44 43 15 72 53 43 72 53 43 68 53 43 67 53 43 61 53 43 55 53 43 51 51 43 47 1 47 43 44 44 43 41 41 41 20 71 53 43 71 53 43 68 53 43 67 53 43 61 53 43 55 53 43 51 51 43 47 47 43 44 44 43 41 41 41 170 25 71 53 43 71 53 43 69 53 43 68 53 43 62 53 43 56 53 43 52 52 43 48 48 43 45 45 43 43 43 43 30 66 61 61 66 61 61 61 61 61 61 61 61 57 57 57 54 54 54 51 51 51 48 48 48 46 46 46 44 44 44 35 66 61 61 66 61 61 62 61 61 62 61 61 59 59 59 56 56 56 53 53 53 51 51 51 48 48 48 46 40 66 1 61 61 66 61 61 63 61 61 63 61 61 60 60 60 58 58 58 55 55 55 53 53 53 51 51 51 49 45 66 60 60 66 60 60 65 1 60 60 65 60 60 62 60 60 60 60 60 58 58 58 56 56 56 54 54 54 53 5 10 65 68 49 50 41 65 68 49 50 41 65 67 49 50 41 65 67 49 50 41 65 62 49 50 62 41 58 49 50 41 57 54 49 50 41 53 49 49 49 41 50 47 49 47 41 47 40 a Mal V 15 68 50 41 68 50 41 67 50 41 66 50 41 61 50 41 55 50 41 51 50 41 47 47 41 44 44 41 41 20 67 50 41 67 50 41 67 50 41 66 50 41 60 50 41 55 50 41 51 50 41 47 47 41 44 44 41 41 1$0 25 67 50 41 67 50 41 67 50 41 67 50 41 61 50 41 56 50 41 52 50 41 48 48 41 45 45 41 43 30 63 58 58 63 58 58 59 58 58 59 58 58 56 56 56 53 53 53 51 51 51 48 48 48 46 46 46 40 35 63 58 58 63 58 58 60 58 58 60 58 58 57 57 57 55 55 55 52 52 52 49 49 49 47 47 47 46 40 63 58 58 63 58 58 61 58 58 61 58 58 59 58 58 56 56 56 54 54 54 52 52 52 49 49 49 48 45 62 57 57 62 57 57 62 57 57 62 57 57 60 57 57 58 57 57 57 57 57 55 55 55 53 53 53 52 Note'. The regions in the gray shade denote an additional installation requirement on UFO middle damps. Please referto Note 11 on Page 2for details. XR100 Flush Mount System Span Table (inches) Portrait Installation (Maximum Module Length 78.5") Exposure D Wind Roof Ground Snow: 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf Speed (mph) Slope (d eg5.) Zonel Zone2 Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone 5 98 75 60 92 75 60 JJ 75 60 76 75 60 68 68 60 62 62 60 57 57 57 53 53 53 50 50 50 47 47 47 10 102 76 61 90 76 61 75 75 61 74 74 61 66 66 61 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 15 101 75 61 89 75 61 75 75 61 70 JO 61 62 62 61 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 99 74 60 88 74 60 75 74 60 70 JO 60 62 62 60 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 110 25 97 74 60 89 74 60 75 74 60 71 71 60 62 62 60 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 87 85 85 81 81 81 71 71 71 70 70 JO 64 64 64 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 35 86 84 84 82 82 82 73 73 73 72 72 72 67 67 67 62 62 62 56 56 56 53 53 53 49 49 49 47 47 47 40 86 83 83 83 83 83 75 75 75 74 74 74 70 70 JO 66 66 66 61 61 61 57 57 57 54 54 54 51 51 51 45 85 82 82 1 85 82 82 78 78 78 JJ JJ JJ 73 73 73 69 69 69 66 66 66 62 62 62 59 59 59 56 56 56 5 94 71 57 92 71 57 JJ 71 57 76 71 57 68 68 57 62 62 57 57 57 57 53 53 53 50 50 50 47 47 47 10 98 72 58 90 72 58 75 72 58 74 72 58 66 66 58 59 59 58 54 54 54 49 49 49 47 47 47 44 44 44 15 96 72 58 89 72 58 75 72 58 70 JO 58 62 62 58 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 20 95 71 58 88 71 58 75 71 58 70 JO 58 62 62 58 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 115 25 90 JO 57 89 JO 57 75 JO 57 71 JO 57 62 62 57 56 56 56 52 52 52 48 48 48 45 45 45 43 43 43 30 80 81 81 79 79 79 70 70 JO 69 69 69 63 63 63 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 35 83 81 81 80 80 80 1 72 72 72 71 71 71 66 66 66 61 61 61 56 56 56 53 53 53 49 49 49 47 47 47 40 83 80 80 81 80 80 74 74 74 73 73 73 69 69 69 64 64 64 61 61 61 57 57 57 54 54 54 51 51 51 45 83 79 79 83 79 79 76 76 76 76 76 76 72 72 72 69 69 69 66 66 66 62 62 62 59 59 59 56 56 56 5 90 68 55 90 68 55 JJ 68 55 76 68 55 68 68 55 62 62 55 57 57 55 53 53 53 50 50 50 47 47 47 10 94 69 56 1 89 69 56 75 69 56 73 69 56 66 66 56 59 59 56 54 54 54 49 49 49 47 47 47 44 44 44 15 93 69 56 88 69 56 74 69 56 JO 69 56 62 62 56 55 55 55 51 51 1 51 47 47 47 44 44 44 41 41 41 20 91 68 55 87 68 55 74 68 55 JO 68 55 62 62 55 55 55 55 51 51 51 47 47 47 44 44 44 41 41 41 120 25 90 68 55 88 68 55 75 68 55 71 68 55 62 62 55 56 56 55 52 52 52 48 48 48 45 45 45 43 43 43 30 81 78 78 JJ JJ JJ 69 69 69 68 68 68 63 63 63 59 59 59 54 54 54 49 49 49 47 47 47 44 44 44 35 81 78 78 78 78 78 70 70 70 70 70 JO 66 66 66 61 61 61 56 56 56 53 53 53 49 49 49 47 47 47 40 81 JJ JJ 79 JJ JJ 72 72 72 72 72 72 68 68 68 63 63 63 60 60 60 57 57 57 54 54 54 51 51 51 45 80 76 76 80 76 76 1 75 75 75 74 74 74 71 71 71 68 68 68 64 64 64 61 61 61 59 59 59 56 56 56 5 83 63 50 83 63 50 JJ 63 50 76 63 50 68 63 50 62 62 50 57 57 50 53 53 50 50 50 50 47 47 47 10 8J 64 52 86 64 52 73 64 52 72 64 52 66 64 52 59 59 52 54 54 52 49 49 49 47 47 47 44 44 44 15 86 64 52 85 64 52 72 64 52 JO 64 52 62 62 52 55 55 52 51 51 51 47 47 47 44 44 44 41 41 41 20 85 63 51 1 85 63 51 72 63 51 JO 63 51 62 62 51 55 55 1 51 51 51 51 47 1 47 47 1 44 44 44 41 41 41 130 25 80 63 51 84 63 51 73 63 51 71 63 51 62 62 51 56 56 51 52 1 52 1 51 48 48 48 45 45 45 43 43 43 30 JJ 73 73 74 73 73 67 67 67 66 66 66 61 61 61 57 57 57 54 54 54 49 49 49 47 47 47 44 44 44 35 J6 72 72 75 72 72 68 68 68 67 67 67 63 63 63 60 60 60 56 56 56 53 53 53 49 49 49 47 47 47 40 J6 72 72 76 72 72 70 70 JO 69 69 69 66 66 66 62 62 62 59 59 59 56 56 56 54 54 54 51 51 51 45 J6 71 71 76 71 71 72 71 71 71 71 71 68 68 68 66 66 66 63 63 63 60 60 60 57 57 57 55 55 55 5 JJ 58 47 JJ 58 47 JJ 58 47 76 58 47 68 58 47 62 58 47 57 57 47 53 53 47 50 50 47 47 47 47-- 10 81 59 48 81 59 48 1 71 59 48 JO 59 48 65 59 48 59 59 48 54 54 48 49 49 48 47 47 47 44 44 44 15 80 59 48 80 1 59 48 71 1 59 48 1 69 59 48 1 62 59 48 55 55 48 51 51 48 47 47 47 44 44 44 41 1 41 41 20 79 59 48 79 59 48 71 59 48 69 59 48 62 59 48 55 55 48 51 51 48 47 47 47 44 1 44 44 41 41 41 140 25 78 58 48 78 58 48 71 58 48 JO 58 48 62 58 48 56 56 48 52 52 48 48 48 48 45 45 45 43 43 43 30 72 68 68 71 68 68 64 64 64 64 64 64 60 60 60 56 1 56 1 56 53 53 53 49 49 49 47 47 47 44 44 44 35 72 68 68 72 68 68 66 66 66 65 65 65 62 1 62 62 59 59 59 11 55 55 1 55 52 52 52 49 49 49 47 47 47 40 72 67 67 72 67 67 67 67 67 67 67 67 64 64 64 61 61 61 57 57 57 55 55 55 53 53 53 51 51 51 45 72 67 67 72 67 67 69 67 67 69 67 67 66 66 66 63 63 63 61 61 61 59 59 59 56 56 56 54 54 54 5 72 54 44 72 54 44 72 54 44 72 54 44 68 54 44 62 54 44 57 54 44 53 53 44 50 50 44 47 47 44 10 75 56 45 75 56 45 JO 56 45 69 56 45 64 56 45 59 56 45 54 54 45 49 49 45 47 47 45 44 44 44 15 75 55 45 75 55 45 69 55 45 68 55 45 62 55 45 55 55 45 51 51 45 47 47 45 44 44 44 41 41 41 20 74 55 45 74 55 45 69 55 45 68 55 45 62 55 45 55 55 45 51 51 45 47 47 45 44 44 44 41 41 1 41 150 25 73 55 45 73 55 45 JO 55 45 69 55 45 62 55 45 56 55 45 52 52 45 48 48 45 45 45 45 43 43 43 30 69 64 64 68 64 64 62 62 62 1 62 62 62 58 58 58 55 55 55 52 52 52 49 49 49 47 4J 47 44 44 44 35 68 63 63 68 63 63 63 63 63 63 63 63 60 60 60 56 56 56 54 54 54 51 51 51 48 48 48 47 47 47 40 68 63 63 68 63 63 65 63 63 64 63 63 62 62 62 59 59 59 56 56 56 54 54 54 52 52 52 49 49 49 45 68 63 63 68 63 63 67 63 63 66 63 63 64 63 63 61 61 61 59 59 59 57 57 57 55 55 55 53 53 53 5 68 51 41 68 51 41 68 51 41 68 51 41 68 51 41 62 51 41 57 51 41 53 51 41 50 50 41 47 47 41 10 71 52 42 71 52 42 68 52 42 67 52 42 62 52 42 58 52 42 54 52 42 49 49 42 47 47 42 44 44 42 15 JO 52 42 JO 52 42 68 52 42 67 52 42 61 52 42 55 52 42 51 51 42 47 47 42 44 44 42 41 41 41 20 JO 52 42 JO 52 42 68 52 42 67 52 42 61 52 42 55 52 42 51 51 42 47 47 42 44 44 42 41 41 41 160 25 69 51 42 69 51 42 68 51 42 67 51 42 62 51 42 56 51 42 52 51 42 48 48 42 45 45 42 43 43 42 30 65 60 60 65 60 60 60 60 60 60 60 60 57 57 57 54 54 54 51 51 51 48 48 48 46 1 46 46 44 44 40 35 65 1 60 60 65 60 60 61 60 60 61 60 60 58 58 58 55 55 55 53 53 53 51 51 51 48 48 48 46 46 46 40 65 59 59 65 59 59 63 59 59 62 59 59 60 59 59 57 57 57 55 55 55 58 53 56 53 56 53 56 51 54 51 54 51 54 48 52 48 52 48 52 45 60 59 59 60 59 59 60 59 59 60 59 59 61 59 59 59 59 59 58 58 170 5 10 64 67 48 49 49 49 48 SJ SJ 64 67 66 66 65 62 48 49 49 49 48 SJ 38 40 4 SJ 64 67 66 66 65 58 48 49 SJ 64 66 65 65 65 58 48 49 49 49 48 5J 38 40 4 SJ 64 61 60 60 61 55 48 49 49 49 48 55 62 SJ 55 55 56 55 53 48 49 49 49 48 53 38 40 4 53 57 54 51 51 52 49 48 49 49 49 48 49 49 53 49 4J 4J 48 47 48 49 47 47 48 47 38 40 4 47 50 47 44 44 45 45 48 47 44 44 45 45 45 47 44 41 41 43 40 47 44 41 41 43 m 15 66 20 66 25 65 30 62 49 49 48 SJ 35 62 SJ 5J 62 SJ SJ 59 SJ 5J 59 5J SJ 56 56 56 54 54 54 52 52 52 49 49 49 47 47 4J 45 40 61 56 56 61 56 56 60 56 56 60 56 56 58 56 56 56 56 56 54 54 54 52 52 52 49 49 49 48 45 61 56 56 61 56 56 61 56 56 61 56 56 59 56 56 58 56 56 56 56 56 54 54 54 53 53 53 51 180 5 10 60 63 45 46 8 60 63 45 3 38 38 37 3 54 60 63 63 62 62 56 45 46 46 46 46 54 8 8 J 54 60 63 63 62 62 56 45 3 38 38 3J 3 54 60 60 59 59 60 54 45 46 46 46 46 54 60 8 56 8 55 J 55 55 54 51 45 46 46 46 46 51 3 38 38 37 3 51 57 53 51 51 52 48 45 46 46 46 46 48 8 8 J 48 53 49 47 47 48 46 45 46 46 46 46 46 3 38 38 37 3 46 50 4J 44 44 45 45 45 46 44 44 45 45 8 8 J 45 47 44 41 41 43 43 CWC �^^�11 46 46 46 15 63 20 62 46 8 63 46 J 62 46 46 46 46 25 62 30 59 46 62 54 54 59 46 54 54 35 58 54 54 58 54 54 57 54 54 57 54 54 5554 54 53 53 53 51 51 51 48 48 48 46 46 46 45 40 58 53 53 58 53 53 58 53 53 58 53 53 56 53 53 54 53 53 52 52 52 51 51 51 48 48 48 47 45 58 53 53 58 53 53 58 53 53 58 53 53 5J 53 53 56 53 53 54 53 53 53 53 53 52 52 52 49 Note'. The regions in the gray shade denote an additional installation requirement on UFO middle damps. Please refer to Note 11 on Page 2for details. AT ON CONTAINED INTHIS DAERANG IS THE PLAN VIEW Aodule Mounting System Bonding Mid C 17all NOT 91 )e UJ/ I6/1UI/ Module Mounting System Bonding End Clamp DETAIL A IRONRI IIIteb9.I► [6I11II[00..11V►1 . L.1 r 1& w .I EX -0015 EXHIBIT: EX -0015 - page 1 of 3 SCALE: NTS I E,G„,:N,q T s„EET1.1 PROPRIETARY AND CONFIDENTIA THE INFORMATION CONTAINED INTHIS EMERSON IS THE PERAINSIONOF NONRIDGE INC IS PROHIBITED 0.4XL(MA STA I q Module Mounting System Bonding End Clar PV Modul . ( MAX) I -A131 II II,_f. I\VVI JII US - IVIG DETAIL C EXHIBIT: EX -0015- page 2 of 3 Rail Attachment (FlashFoot2 Cap Dwn for Reference) )dule Mounting S) Bonding Mid Clar PV Modul -Fing 'Shown f ince) DETAIL E DETAIL D 17 Jule Gap 'P) Module AL IRON RIDC FLUSH MOUNT SYSTEM THE INFORMATION CONTAINED INTF NONRIDGE INC AW REPRODUCTIC PERAINSIONOF NONRIDGE INC IS Fla (Flasl Shown for XR10 XR100 XR1000 FLUSH MOUNT SYSTEM )17 EX -0015 EXHIBIT: EX -0015 - page 3 of 3 11AFE:H,s -IH,:. SHEET OF FAWNS RESIDENCE 3430 WARD RD WHEAT RIDGE, CO 80033 Approval Notes: 1) PN array system to have grounding system installed per Part III of Article 250 per 2017 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental ground rods per 2017 NEC Article 250.53(A)(3). 3) Natural Gas & Cold Water bonding per 2017 NEC Article 250.104(6) AUTHORITY HAVING JURISDICTION BUILDING AUTHORITY CITY OF WHEAT RIDGE CODE REFERENCE 2017 NEC ELECTRICAL UTILITY COMPANY XCEL ENERGY DESIGN CRITERIA DESIGN WIND LOAD 135 MPH DESIGN ROOF SNOW LOAD 30 PSF EXPOSURE CATEGORY C HIGH TEMP (ASHRAE 2% HIGH) 34°C LOW TEMP (ASHRAE EXTREME LOW) -25°C EEEEI ROOF TYPE ASPHALT SHINGLE 202000786 4.55 KW DC ROOF MOUNTED PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM DETAILS SYSTEM SIZE, STC, DC 4.55 KW MODULE RATING, STC, DC 350 W (13 PCS) INVERTER SOLAREDGE-SE5000HD-US RACKING SYSTEM IRONRIDGE XR100 W/ FLASHFOOT2 DATA ACQUISITION CELL MODEM City of ' W heat lidge COMMUNITY DEVELOPMENT APPROVED Reviewed for Code Compliance ,iw. /,L� 5.6.2020 Plans Examiner Date valldity of oermll: The issuer" o f o permitor *provW of pians sW4konow and compurohons shaft not be o permit for, or an approval of any vrorobon w any of the provisions 4 the bwld/ng code or of o(W City ardirronaes. Permits presuming to glue outhorlty to Uwam or w"el the prwrm" e f the swift codes or other oreffmooes of Me Oty:hod not be vaftoL VICINITY MAP EJU:� SHEET INDEX PV -G.0 COVER PAGE PV-A.I ARRAY LAYOUT PV -A.2 ATTACHMENT DETAIL PV -E.1 LINE DIAGRAM PV -E.2 ELECTRICAL CALCS PV-P.I PLACARDS PV -P.2 PLACARDS U) a= Ea 0 J Co oo 6-4 0 vi aUo m wp IS U > m o m o. 1-0 1-0 LU o U o Z 00 W O 0 p U LU LU cn o — Z ry Q Q LL w NAMASTE CONTACT KEENAN TUEE BEIRI (72S)111-1117 EB BE SOLARCOM NAMASTE S SIGNER. TODD HAMMERBACHER Z SYSTEM O 13 MODULES 4.55 KW Zw w, MODULES Q = LG Z U LG350NIC-V5 .J m INVERTER(S) 12 C • SOLAREDGE U. SE5000HD-US WF v/ O m COVER PAGE 0 NOT TO SCALE H PV -G.0 3' ARRAY INFORMATION MOD QTY 15 TILT 18° AZIMUTH 179- I ROOF CONSTRUCTION I ASPHALT SHINGLE PV ARRAY - 241 SQUARE FEET MAX ATTACHMENT SPAN - 48" MAX CANTILEVER - 18" ATTACHMENTS SHALL BE STAGGERED SO THE LOAD IS DISTRIBUTED EVENLY TO RAFTERS UNDERNEATH THE ARRAY. FIRE SETBACKS ARE 36" FROM RIDGE WITH 36" PATHWAYS ON BOTH SIDES OF ARRAY/18" FROM VALLEY. - EXTERIOR JNECT - EXTERIOR RODUCTION METER R ,IN DISCONNECT R /ICE PANEL R - INTERIOR LV VV I LLT -INTERIOR 11 N Ea OJ CO Q° NO NO W U O Z 00 W O oo� ry waw cn O — zNOFy < NO LL LLJ --E NTACT KEENAN LUEEERS �-AN LUEBBE—NAM—EWLAR COM �4, SYSTEM • 15 MODULES • 4.55 KW MODULES • LG • LG550NIC-V5 INVERTERS, • SOLAREDGE • SE5000HD-US ARRAY STRING CONFIGURATION LAYOUT NOT TO SCALE STRING SIZE DOES NOT VARY STRINGS DTV ^ . STRING 1 13 H ooco 8-4 PV MODULE CRY of o� 11 M Q >• E pp m o o IRONRIDGE �m v RAIL�n v m LLz ROOF ww 1 MEMBRANE q Lu C) UO 0 00 Z W O 0 U IRONRIDGE a FLASHFOOT2 W Q LU w BUILDING a cf) O — STRUCTURE z ARRAY WILL NOT PEAK p j Z Q Q J OVER RIDGE OF ROOF LL_ Lu ° IRONRIDGE RAIL _ IRONRIDGE FLASHFOOT2 NAMASTE CONTACT. KEENAN LUEBBERS 8-459) (EENAN LUERBERS-AMASTESOLAR CON NAMASTE DESIGNER. TODD HAMMERBACHER SYSTEM • 13 MODULES • 4.55 KW MODULES • LG • LG350NIC-V5 INVERTER(S) • SOLAREDGE • SE5000HD-US ATTACHMENT DETAIL NOT TO SCALE PV -A.2 EQUIPMENT SCHEDULE KEY Ott MAKE MODEL LOCATION 1 13 LG LG350NIC-V5 FLUSH MOUNTED TO ROOF 2 13 SOLAREDGE P400 MOUNTED ON RACKING 3 1 SOLADECK 0799-56 UNDERNEATH ARRAY 4 1 SOLAREDGE SE500OHD-US EXTERIOR 5 1 SQUARE D DU221RB EXTERIOR 6 1 MILBANK _.801 -XL -519 EXTERIOR 7 1 SIEMENS TBD MAIN SERVICE PANEL, OPPOSITE SIDE OF MAIN BREAKER 8 1 SIEMENS TBD INTERIOR 9 1 SIEMENS TBD EXTERIOR 10 1 TBD TBD INTERIOR 11 1 TBD TBD INTERIOR 12 1 TBD TBD EXTERIOR MAIN SERVICE PANEL, 200A BUS, MLO, 24OV, FED BY 15. PV WIRED INTO LINE SIDE OF PRODUCTION METER MAIN DISCONNECT, 200A, 240V INTERCONNECTION_ LOAD -SIDE, IN MAIN PANEL KEY ELECTRICAL NOTES NOTES PV MODULE GENERAL 1. PLACARDING AS REQUIRED PER 690.13, .15, .31, .51, .52, .53, .54, .56, 705.10, 705.12 2. PLACARD AT METER INDICATING "PHOTOVOLTAIC SYSTEM CONNECTED" 3. SERVICE DISCONNECTS SHALL BE GROUPED AND/OR MARKED WITH LOCATION DESCRIPTION(S) 4. GEC SHALL BE CONTINUOUS PER 250.64(C) POWER OPTIMIZER PV ROOF JUNCTION BOX, NEMA 3R DC DISCONNECT INTEGRATED INVERTER PV AC DISCONNECT, NEMA 3R CAR, 240V PV PRODUCTION METER LEVER BYPASS, 200A, 240V PV BREAKER, I X BAWDY MAIN SERVICE PANEL, 200A BUS, MLO, 24OV, FED BY 15. PV WIRED INTO LINE SIDE OF PRODUCTION METER MAIN DISCONNECT, 200A, 240V INTERCONNECTION_ LOAD -SIDE, IN MAIN PANEL O v no N G I / CRY of NO w O U Z p SO W O p p U LU Q COO O — z % 13� Q Q LL LLJ KEENAN WEBBERS (rzo)ma STESOuuon NAMSTnreSIGNER TODD • 13 MODULES • 4.55 KW MODULES • LG • LG 350N1 C -V5 INVERTER(S) • SOLAREDGE • SE5000HD-US L IIVC DIAGRAM NOT TO SCALE PVI I KEY CONDUCTORS CU/AL IE I LOCATION I RACEWAY A 2x12, 1-410 ECAC Cu WIRE ARRAY FREE AIR B 2-#12,1-#12(OR LARGER) EGC,1/2"OR LARGER RACEWAY Cu THHN/ THW N2 INT/EXT FMC/EMT C 3x10, 1x10 EGc, v2' OR LARGER RACEWAY Cu THHN/ THW N2 INT/EXT FMC/EMT STRING OF 13 MODULES Approval Notes: 7) PN array system to have grounding system installed per Part III of D 3x3. 1x8 EGc. 1-1/4" ORCU LARGER RACEWAY THHN/ THWNz INTERIOR FMC/EMT E EXISTING Article 250 per 2077 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental F 3x8, Ix 10 EGc, 3/4^ OR LARGER RACEWAY Cu THHN/ THWNz INTERIOR FMC/EMT ground rods per 2077 NEC Article 250.53(A)(3). OO3) Natural Gas S Cold Water bonding per 2077 NEC Article 250.704(8) 7 O v no N G I / CRY of NO w O U Z p SO W O p p U LU Q COO O — z % 13� Q Q LL LLJ KEENAN WEBBERS (rzo)ma STESOuuon NAMSTnreSIGNER TODD • 13 MODULES • 4.55 KW MODULES • LG • LG 350N1 C -V5 INVERTER(S) • SOLAREDGE • SE5000HD-US L IIVC DIAGRAM NOT TO SCALE PVI I MODULE SPECS AND CALCULATIONS ITEM PARAMETER UNIT CALCULATED LIMIT ITEM NOTE L YaLc UNIT DETAIL INVERTER MAKE INVERTER SPEC POWER OPTIMIZER MAKE SOLAREDGE INVERTER MODEL INVERTER SPEC POWER OPTIMIZER MODEL SE5000HDL5 INVERTER MAX POWER, (WAC MAX) ITEM NOTE L YALc UNIT DETAIL INVERTER INPUT V, (Voc MAX) INVERTER SPEC VOLTS (oc) N 0s LOCATION SPEC VOLTS (AC) WHEAT RIDGE, CO 80033 INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 Om TEMP, AMBIENT HIGH (TMAX) ASHRAE 2% °C 34 INVERTER PHASE INVERTER SPEC PHASE I COMPLIANCE TEMP, AMBIENT LOW (THIN) ACHRAE EXTR. MIN °C -25 INVERTER eRouNDwe INVERTER SPEC COU UNGROUNDED o TEMP, MODULE TEST )TTFSTJ MODULE SPEC °C 25 OC OPTIMIZED INPUT VOLTAGE VOW VOLTS (oc) CO PER NEC TEMP, DELTA LOW (TOELTA) THIN -TTFST °C -50 MAX INPUT CURRENT PER STRING (1MAXOC) (MDDOTY*WDC)/VOPT AMPS (oc) 11.9J MAX OUTPUT CURRENT (IMAxoc) (IAc*L25) MODULE MANUFACTURER MODULE SPEC 26.25 LG 100 100.00 IOOA #B Cu MODULE PART NUMBER MODULE SPEC 55 LG350NIC-V5 L00 52.80 TERM 50 MODULE POWER STC (P) MODULE SPEC WALLOON) 350 OITION OF ISE (CJID(AMPACITYTEMPOERATEFILLOERATE) VSRE(]O (IMAq GERM)AMPAOTY AT TERMINALSVSRE(]OPIMA% X125) FlINALS ALL WIRES SIZED RIO OR LESS ARE IN COMPLIANCE WITH 240 .4(0) �� m3 MODULE OPERATING VOLTAGE (VMP) MODULE SPEC VOLTS (V) 35.3 STRING CONFIGURATION STRINGS OTY MOOLLES MODULE OPEN -CIRCUIT VOLTAGE (Voc) MODULE SPEC VOLTS (V) 41.3 SOLAREDGE - P400 MODULE COEFFICIENT, VOLT/TEMP (COEFF) MODULE SPEC (%/°C) /100 -0.0024 MODULE OPERATING CURRENT (IMP) MODULE SPEC AMPS U+) 9.9z MODULE SHORT-CIRCUIT CURRENT AMPS (A) (6c) MODULE SPEC 10.61 MODULE MAX VOLTAGE (VMAXMOO) (Voc + Voc(To*COEFF)) VOLTS (oc) 46.26 MODULE MAX CURRENT (IMAX) (Isc * L25) AMPS (oc) 13.26 0 DJ MIN AMPACITY REQ D, U p 0 co z w 0 p p U a Q DJ W p Q 0 a z �% > L O Q Q LL g UJ 0 HANDATE CONTACT KEENAN LUEBBERS (rzme4A WE NANDAHE DESIGNER TIED HAMMEREACHER SYSTEM • 13 MODULES 4.55 KW MODULES LG • LG350NIC-V5 INVERTERS) • SOLAREDGE • SE5000HD-US Gqr d ELECTRICAL CALCS NOT TO SCALE PV -E.2 INVERTER SPECS AND CALCULATIONS ITEM PARAMETER UNIT CALCULATED LIMIT ITEM NOTE L YaLc UNIT DETAIL INVERTER MAKE INVERTER SPEC POWER OPTIMIZER MAKE SOLAREDGE INVERTER MODEL INVERTER SPEC POWER OPTIMIZER MODEL SE5000HDL5 INVERTER MAX POWER, (WAC MAX) INVERTER SPEC WATTS (AC) 5000 INVERTER INPUT V, (Voc MAX) INVERTER SPEC VOLTS (oc) 480 INVERTER OUTPUT V, )VAC NOM) INVERTER SPEC VOLTS (AC) 240 INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 INVERTER OUTPUT CURRENT, )IACD INVERTER SPEC AMPS (AC) 21 INVERTER PHASE INVERTER SPEC PHASE I COMPLIANCE INVERTER SPEC ULII4IAEEEI54I INVERTER eRouNDwe INVERTER SPEC COU UNGROUNDED INVERTER DTV NVOTY 38.40 DTV OC OPTIMIZED INPUT VOLTAGE VOW VOLTS (oc) 380 PER NEC (IMAX * L25) AMPS (oc) 16.58 INVERTER SPECS AND CALCULATIONS ITEM PARAMETER UNIT CALCULATED LIMIT ITEM NOTE L YaLc UNIT DETAIL INVERTER MAKE INVERTER SPEC POWER OPTIMIZER MAKE SOLAREDGE INVERTER MODEL INVERTER SPEC POWER OPTIMIZER MODEL SE5000HDL5 INVERTER MAX POWER, (WAC MAX) INVERTER SPEC WATTS (AC) 5000 INVERTER INPUT V, (Voc MAX) INVERTER SPEC VOLTS (oc) 480 INVERTER OUTPUT V, )VAC NOM) INVERTER SPEC VOLTS (AC) 240 INVERTER OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 INVERTER OUTPUT CURRENT, )IACD INVERTER SPEC AMPS (AC) 21 INVERTER PHASE INVERTER SPEC PHASE I COMPLIANCE INVERTER SPEC ULII4IAEEEI54I INVERTER eRouNDwe INVERTER SPEC COU UNGROUNDED INVERTER DTV NVOTY 38.40 DTV OC OPTIMIZED INPUT VOLTAGE VOW VOLTS (oc) 380 MODULE OTV PER BRANCH CIRCUIT MODRry #3 OTV 13 MAX INPUT CURRENT PER STRING (1MAXOC) (MDDOTY*WDC)/VOPT AMPS (oc) 11.9J MAX OUTPUT CURRENT (IMAxoc) (IAc*L25) AMPS (AC) 26.25 POWER OPTIMIZER SPECS ITEM PARAMETER UNIT CALCULATED LIMIT PANEL MAX INPUT POWER WATTS (W) 360 ITEM NOTE L rnLc 8 UNIT DETAIL POWER OPTIMIZER MAKE OPTIMIZER SPEC 15 SOLAREDGE POWER OPTIMIZER MODEL OPTIMIZER SPEC #12 P400 MAX INPUT POWER iwoc MAX) OPTIMIZER SPEC WATTS (oc) 400 MIN INPUT VOLTAGE, (Voc MIN) OPTIMIZER SPEC VOLTS (oc) 8 MAX INPUT VOLTAGE, (Voc MAX) OPTIMIZER SPEC VOLTS (oc) 80 MAX SHORT-CIRCUIT CURRENT (ISC) OPTIMIZER SPEC AMPS (oc) 10 MAX OUTPUT CURRENT OPTIMIZER SPEC AMPS (oc) 15 OPTIMIZER EXTREME OPERATING CONDITIONS ITEM PARAMETER UNIT CALCULATED LIMIT PANEL MAX INPUT POWER WATTS (W) 360 400 MIN INPUT VOLTAGE VOLTS (V) 3J 8 MAX INPUT VOLTAGE VOLTS (V) 48 80 MAX SHORT-CIRCUIT CURRENT (6c) AMPS (A) II 10 MAX OUTPUT CURRENT AMPS (A) 12 15 MAX OUTPUT VOLTAGE VOLTS (V) 60* RE(]'O W ^OPTIMIZER OUTPUT VOLTAGE RANGE BETWEEN Sfi0 VRC-STRING VOLTAGE IS REGULATED BY THE INVERTER (NOT TO E%CEER 48MRQ NOTE CALCULATED VALUES ARE THE ABSOLUTE MIN/MA% OF ALL ARRAYS USING THIS POWER OPTIMIZER CONFIGURATION MAXIMUM STRING VOLTAGE IS 480VOC (INVERTER REGULATED) CONDUCTOR SIZING CALCULATIONS ITEM UNIT PANEL BUS RATING AMPS KEY SIZE N/AL INSULATION ULG TYPE AMPACITY W W/0 AERATES TEMP. OERATE FILL OERATE RESULT W RE(]'O W OCPO A #12 CU PV WIRE COU 30 0.96 0.80 23. C4 15.00 TERM 25 25 18 75 B #12 CU THHN/THWN2 COU 30 0.96 0.80 23. C4 15.00 TERM 25 25 18 75 C #10 Cu THHN/THWN2 COU 40 0.96 L00 38.40 21.00 TERM 35 35 26.25 30A D #3 Cu THHN/THWN2 COU 115 0.96 L00 110.40 TERM 100 100 100.00 IOOA #B Cu THHN/THWN2 COU 55 0.96 L00 52.80 TERM 50 50 50.00 50A OITION OF ISE (CJID(AMPACITYTEMPOERATEFILLOERATE) VSRE(]O (IMAq GERM)AMPAOTY AT TERMINALSVSRE(]OPIMA% X125) FlINALS ALL WIRES SIZED RIO OR LESS ARE IN COMPLIANCE WITH 240 .4(0) STRING CONFIGURATION STRINGS OTY MOOLLES OPTIMIZERS STRING I 13 LG350NIC-V5 SOLAREDGE - P400 INTERCONNECTION CALCULATIONS ITEM UNIT PANEL BUS RATING AMPS 200 MAIN DISCONNECT AMPS 200 ALLOWED PV PER NEC AMPS 40 PV OCPD USED AMPS 30* 'BACKFED BREAKER ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. PANEL FED BY PLACARDS NEC 690.13(B): I LABEL(s) LOCATED ON MAINS PANEL LOCATED INSIDE PV AND UTILITY AND ANY SUBPANEL DC DISCONNECT • • • PHOTOVOLTAIC NEC 690.54: NEC 690.13(B): I LABEL(s) IPLACARD(S) SYSTEM CONNECTED LOCATED INSIDE MAIN AC LOCATED ON DC DISCONNECT PANEL NEC 690.53: I LABEL(S) LOCATED ON DC DISCONNECT lea • • NEC 690.13(B): I PLACARD(S) LOCATED AT AC DISCONNECT NEC 690.31(G)(3)(4) LABELS LOCATED ON ALL PV SOURCE/ OUTPUT ENCLOSURES INSIDE BUILDING PV PRODUCTION METER 3430 WARD RD NEC 690.54: 1 PLACARD(S) LOCATED ON AC DISCONNECT UTILITY REQUIREMENT: I BRASS TAG LOCATED ON XCEL PV PROD METER HOUSING UTILITY REQUIREMENT: I BRASS TAG LOCATED ON XCEL PV PROD METER HOUSING "ALL PLACARDING TO COMPLY WITH THE 2017 NATIONAL ELECTRICAL CODE' NO W Oo z p00 W O p p O W W Q W W � � U) o W - z NO Q NO Q W W CONTACTNAMASTE KEENANLOEBBERS (111) ser SYSTEM • 15 MODULES • 4.55 KW MODULES LG • LG550NIC-V5 NVERTER(S) • SOLAREDGE • SE5000HD-US PLACARDS NOT TO SCALE PV -P 0 mvo ®WARNING NEC 705.12(B)(2)(3)(e): NEC 690.56(C)(3): vo POWER SOURCE LABEL PLACARD c� m, LOCATED AT PV BREAKER • ' • ' LOCATED ON EXTERIOR AC e m OUTPUT CONNECTION DISCONNECT do DO NOT RELOCATE SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN U-1 CD TURN RAPID SHUTDOWN NEC 690.12 & Op CD SWITCH roTHE 690.56(C)(1)(A): W O "OFF" POSITION TO I PLACARD Q U $ SHUTDOWN PV SYSTEM AND REDUCE LOCATED AT RAPID SHUTDOWN SHOINARRAAV� SERVICE DISCONNECT I p U) O a z: NO Q Q 3 LL. W 0 KEENAN WEBERS (rzo)5 , 17 TODD HAMMEREACHER SYSTEM • 15 MODULES • 4.55 KW MODULES CRY or I. LG • LG550NIC-V5 NVERTER(S) • SOLAREDGE • SE5000HD-US PLACARDS NOT TO SCALE PVI "ALL PLACARDING TO COMPLY WITH THE 2017 NATIONAL ELECTRICAL CODE"" CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN INVERTER - EXTERIOR AC DISCONNECT - EXTERIOR UTILITY PRODUCTION METER - EXTERIOR METER/MAIN DISCONNECT - EXTERIOR MAIN SERVICE PANEL - INTERIOR SUBPANEL - INTERIOR EV OUTLET - INTERIOR N City of Wheat Ridge E -Res. Electrical Service PERMIT - 202000858 PERMIT NO: 202000858 ISSUED: 05/08/2020 JOB ADDRESS: 3430 Ward Rd EXPIRES: 05/08/2021 JOB DESCRIPTION: Electrical service change, installing 100 AMP sub panel and EV charging circuit to existing service. *** CONTACTS *** OWNER (303)447-0300 FAWNS BRIAN A SUB (303)447-0300 JEFF DENOVAN 090413 NAMASTE SOLAR *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,250.00 FEES Total Valuation 0.00 Use Tax 26.25 Permit Fee 53.70 ** TOTAL ** 79.95 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Smoke alarms shall comply with 2012 IRC Section 134. INTERIOR ALTERATIONS, REPAIRS, FUEL -FIRED APPLIANCE REPLACEMENTS, OR ADDITIONS, ANY OF WHICH REQUIRE A BUILDING PERMIT, OCCURS OR WHERE ONE OR MORE ROOMS LAWFULLY USED FOR SLEEPING PURPOSES ARE ADDED SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN FIFTEEN FEET OF THE ENTRANCE TO EACH ROOM LAWFULLY USED FOR SLEEPING PURPOSES PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. Electrical Service PERMIT - 202000858 202000858 ISSUED: 05/08/2020 3430 Ward Rd EXPIRES: 05/08/2021 Electrical service change, installing 100 AMP sub panel and EV charging circuit to existing service. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its` accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired penriits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. Th ssuance or jogrr�ogrdifnanpce a ermit shall not be construed to be a permit for, or an approval of, any violation of any provision of any ap l le ode or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheot Ridgc O5/O8/282O 108 25 CDBA Be!-- tri -L siervicyc CDA022690 BPSP WO Ward Rd AMOUNT ?995 APPL/PFRMlT NO: 292999858 ' PAYMENT RECEIVED PP / 6824 """"n' ACOD[: 79,99 ` 7UTH 7488O51 TOTAL ___7Y.95 __ Dina Kemp From: no-reply@ci.wheatridge.co.us Sent: Thursday, May 7, 2020 1:00 PM To: CommDev Permits Subject: Online Form Submittal: Electrical Service Change/Upgrade Permit Application Follow Up Flag: Follow up Flag Status: Flagged Categories: Dina Electrical Service Change/Upgrade Permit Application This application is exclusively for RESIDENTIAL ELECTRICAL SERVICE CHANGE OR UPGRADE (200 amps or less). YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes electrical service change or upgrade - 200 amps or less? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Attach City of Wheat Ridge Electronic Payment Form - **DO NOT ATTACH A PICTURE OF A CREDIT CARD** 3430 Ward Rd Brian Fawns 720-323-1069 WheatRidge Elecronic Payment Form.pdf CONTRACTOR INFORMATION 1 Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Namaste Solar Electric Inc 090413 303-447-0300 Contractor Email Address jacob.logar@namastesolar.com Retype Contractor Email Address DESCRIPTION OF WORK Is this an electrical service upgrade or change? Number of Amps Location of upgrade/change (garage, house, etc) jacob.logar@namastesolar.com Change 100 House Provide additional details, Installing 100A sub panel and EV charging circuit to existing if needed. service Project Value (contract 1000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit z has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Jacob Logar Permit Email not displaying correctly? View it in your browser. •y'4 17 pr City of Wheat Ridge Residential Roofin PERMIT RMIT - 201705539 PERMIT NO: SOB ADDRESS: 201705539 JOB DESCRIPTION: esi Ward l ResiISSUED: dential Re -roof to i 08/05/2017 ns C install OweEXPIRES. sq Pitched / 3 sq flat) Corning asphalt h 08/05/2018. *** CONTACTS *** s angles - 19 sq (16 OWNER (720)232-1069 FAWNS SUB (303)981-1265 BRIAN A Jon Lowrie *** PARCEL INFO *** 100243 Monarch Construction ZONE CODE: & Roofing SUBDIVISION CODE: UA / Unassigned 2403 / APPLEWOOD VILLAGES USE: *** FEE SUM MARY *** PROSPECT V BLOCK/LOT#: UA / Unassigned fined 0 / Total Valuation ESTIMATED PROJECT VALUATION: Use Tax FEES 8,000.00 Permit Fee 0.00 ** TOTAL ** 168.0 172.660 340.60 *** COMMENTS *** *** CONDITIONS *** Effective December 1, inspection 2014, asphalt shin conducted when file installations approval. Installation 25-75 percent of the require an when spaced or board °f roof sheathing (new or roof covering is instap�edved midroof mid -roofs sheathing with ANY overlay) is re , prior to f may be called gap exceeding required on the anal complete and in at the same time g °ne half entire roof to complete 25-75 percent of the one hundred inch exists. Sheathing fastened to the mid -roof may be complete. percent g and is required. Eave and rake deck with a minimum be plete. Asphalt shingles must be secured in is required.6 nails per shin are required an s metal is re Place is required A ladder extending file. Ice and water shield whichever applicable roof above the roof is more stringent. codes and/or manufacturer eave type roof cover' gent. In order to installation of ventilation representative ings,a letter of inspection a final ins instructions, stating that pection and pection of elastomeric applied in accordance with the application approval from the manufacturer or similar roof coverin the installation Of the roof at (project technical g" is required to be Of for � address) has on site at the (roof material been Roof the for time of final brand name) ROOFS inspection. party inspection r OVER 6/12 PITCH: Wheat Rid report will be collected 3rd party inspection Ridge. If report is at final roofwill be re not available inspection required, the 3rd the final inspect, on will performed le City of not be completed. S3Uccu tint /T e ION ECORD 31http://Www-c'-"'heatridge.co.us/inspection C ION O L E F 303 234-5933 INS INSPECTION REQUEST LINE: ( of the inspection Cancellations most be submitted via the online form before 8 a.m. the daY f th ed on the project site. performed unless this card the following business day.** Inspections will not be p P.M.midnight) to receive an inspection *Request an inspection before 11:59 pertinent to this project Sign ALL Spaces p Inspector Must Sig Comments - Inspector undation Inspections Date Initials ncrete Encased Ground (CEG) undation I P.E. Letter our Concrete Prior To Approval Of The Above Inst Do Not r Inspector Comments Inspections I Date I Initials ndergroundlSlab Insp — lectrical ;ewer Service dumbing Do Not Cover Unde Rough Inspections Wall Sheathing Mid -Roof Lath 1 W all Tie Rough Electric Rough PlumbinglGas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Scram Final Inspections round or BelowlIn Sle boWork Prior To p Date Initials Landscaping & Parking I Planning Dept. ROW & Drainage I Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection I Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Of Th Above Comments ns Inspector Comments Date Initials Inspections from these entities shoe I abd papkingte one week in advance. For landscaping inspections call 303-235-2846. For ROW and tions age inspections call 303-235-2861. For fire inspections n p contact the Fire Protection District for y project. ons — Final Window/Doors before a Certificate Final Building roved by Planning, Public Works, Fire and Building le ed and a pr Building inspection does not constitute authorization of occupancy. NOTE: All items must be tomo al of the Fina Final Occupancy is issued. App inspections are completed from the Fire District and electrical low voltage of h insp *For low voltage permits – Please be sure that trough y is Issued by the Building Division. ant Is Not Permitted Until A Certificate From TheOccu We pher occupancy protect This C CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F-W&L, Df - Job Address: 1543o klleo Permit Number: 1 -10 275 3 ❑ No one available for inspection: Time !1 �' ' AM/I-ILII Re -Inspection required: Yes N When corrections have been made, call f7e-inspection at 303 -234 - Date: 0� �^i Inspecto DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M i ►i Job Address: 54-2)0 Permit Number: vo I -7 O 9S!5 ❑ No one available for inspection: Time lS2 AM tM Re -Inspection required: Yes (NDo When corrections have been made, call for re -inspection at 303 -234 - Date: -S/14 03 -234 - Date: /1-7 Inspector: �/- DO NOT REMOVE THIS NOTICE City of Wheat Ridge �. Residential Roofing PERMIT - 201705539 J - PERMIT NO: 201705539 ISSUED: 08/05/2017 JOB ADDRESS: 3430 Ward RD EXPIRES: 08/05/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning asphalt shingles - 19 sq (16 sq pitched / 3 sq flat) *** CONTACTS *** OWNER (720)232-1069 FAWNS BRIAN A SUB (303)981-1265 Jon Lowrie 100243 Monarch Construction & Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,000.00 FEES Total Valuation 0.0011-1 Use Tax 168.00 '! Permit Fee 172.60 -- } ** TOTAL ** 340.60 __ -J *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. 11* a' d City of Wheat Ridge Residential Roofing PERMIT - 201705539 PERMIT NO: 201705539 ISSUED: 08/05/2017 JOB ADDRESS: 3430 Ward RD EXPIRES: 08/05/2018 JOB DESCRIPTION: Residential Re -roof to install Owens Corning asphalt shingles - 19 sq (16 sq pitched / 3 sq flat) I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. �L�p - ce, -_Or-rq? Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying Flaps and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original_permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issu%a�!4 f permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicab re ujaf n of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz Z o I i 0 J ,> 3 From: no-reply@ci.wheatridge.co.us Sent: Monday, July 31, 2017 1:01 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Dane Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 3430 ward rd brian fawns 7202321069 Field not completed. Q), Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. Attached Copy of Field not completed. Contract CONTRACTOR INFORMATION Contractor Business monarch construction Name Contractor's License 100243 Number (for the City of Wheat Ridge) Contractor Phone 3039811265 Number Contractor Email Address permits@monarchroofs.com Retype Contractor Email permits@monarchroofs.com Address DESCRIPTION OF WORK Are you re -decking the No / roof? Description of Roofing owens corning Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 16 material selected above? Does any portion of the Yes property include a flat roof? If yes, how many squares 3 on the flat roof? TOTAL SQUARES 19 (pitched + flat) of all 2 roofing material for this proj ect Provide additional detail house reroof here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract i 8000 value or cost of ALL �f materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant brie lowrie Email not displaying correctly? View it in your browser. 3 ;ap WV" —4 4*A— vx& "Rt -"4" ;w .0 W AAW— &Ovw* ap— maw, 4 4 --f 4%,s49v �,"-Vlw-400 *g* z'-,4 --*J�o tga w- Wlzlf ��*w F14P YV —4 4*A— vx& "Rt -"4" ;w .0 W AAW— &Ovw* ap— maw, i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M 10 Job Address: 5,4,-5c) .&P -P (2-17 Permit Number: IQ 1-1 Q!95 3n } i• ❑ No one available for inspection: Time AM PM Re -Inspection required: YesNo When corrections have been made, call for re -inspection at 303-234-5933 Date: ' (S 1 11 Inspector: CAL,— DO NOT REMOVE THIS NOTICE Certificate Of Completion Building Division 7500 W 29TH AVE WHEAT RIDGE CO 80033-8001 Permit#:201400964 Issued: 06/05/2015 Stipulations: Interior Remodel. This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Codeand development standards of the zone district in which it is located and may be occupied. All other licensing requirements for the City must be met. Site Address: 3430 'Ward RD Parcel No: 39-291-08-021 Owner: SANCHEZ MATTHEW D 90 W 84TH AVE DENVER CO 80260 Contractor: Allen George 806 TROY ST AURORA CO 80011-6639 For the Following Purpose: Residential Remodel Code Editions NO change shall be made in the USE of ,;,>,012 ICC/2014 NEC this building without prior notice :Z2006 ICC/2011 NEC and a new Certificate Of Completion 2006 ICC/ 005 NEC from the City of Wheat Ridge. Other C ie u ing Insey tor zoning Administra-t-or C TIFICATE MUST BE POSTED BY FRONT DOOR OF COMMERCIAL OCCUPANCIES Building Permit Application Qt her City Ucens Sus: Other Uty € ceps :r Sub: City Lice nse # Uy License Complete all "t rmati sides of this form of materials tobe used, eto,) f'fL 8 ..,. Btu's Gallons Amps Squares Oflier Building in Division Valuation: Address: W ork shall comply with the 3430 Ward Rd f ollowing codes 2006 IRC, 2006 Wheat Ridge, Co 80260 IECC 201 NEC. Owner: M D Sanchez Lisa C Sanchez 90 W 84' lore Denver, Co 802 Carbon monoxk]c detector(s) required within 15 ft ofall sleeping areas, wt ffi�� DepartmeM tie in existing ",hard hardwood floor and finish. Family r upper level next to kitchen. Existing ceiling was not dry walled. Ceiling was originally finished exposing the W beams 3 ft on center. F ramed ceiling 2 ft on center with 2x4 °s nailed off to original 2A beams for drywall installation, Install a pprox 12 sheets of new drywall to texture at ceilings. Front rod level at front door entry. Frame down a soffat to cover up new plumbing rough. Install approx 12 sleets of new drywall to texture t ceilings and walls. Upstairs main bath rooms Frame beta per plan. Rough in new , plumbing per plan. Drain in /ven and water. Install new tub valve rid bath tub. Install new Exhaust vent. Install dedicated f i outlet and run wiring for exhaust vent. Install a pprox 6 sheets of new drywall to texture t ceilings and ells. Install Y, inch D urrock of tub surrounds Finish Install ceramic the surround and floor, new 24" vanity, sire, a faucet toilet and misc f ixtures. Leave existing 24" door opening, Upstairs Master bathroom Frame bath per plan. Rough in new plumbing per plan. Omits /vent/ and water. Install new tub valve nd bads tub. Install new fsdst vent. Install dedicated fd outlet and run w iring for exhaust vent. Install approx 6 sheets o new dryw all to texture t ceilings and walls install Yt inch Durrock of tub surround Finish- Install 2 " door and triers, ceramic till surround and the floor, new 24" vanity, sink, and faucet toilet and misc fixtures. Laundry room downstairs- Rough in washer machine ppt mbin box. Relocate cutlet for washer machine. Install new dedicated 220 V for Dryer.. Install approx 6 sheets of new drywall to texture at ceilings and walls. Licensed subs to complete electrical. Plumbing and heating. C�� L AY t �l Llik OEM M�t F # ana ana'Tze oo e ove above referenced address. ng rr structurr me ri room at I The existing roof structure over the living room consists of 46 rafters spaced at 3'-0" o.c. with spans from approximately 12'-0" up to approximately 14'-6" toe-nailed to a 6xI4 ridge beam. The existing roof is sheathed with T&G decking over the rafters. Based on a snow load of 30psf and a dead load of 15psf, our office should be reinforced. We have determined by analysis that if the above repair recommendations are implemented the roof structure will be capable of supporting the code required dead and live loads. 0- 2535 17 STREEr, DENVER, CO 80211 0 303-783-4797 0 303-830-9133 FAX * 01 This report should not be considered a warranty or guarantee, implied or expressed, of the home in general, the building superstructure, or the foundation system, Structures and foundation systems may be severely impacted by changes in climate, land-use, etc. The conclusions presented in this report are based on conditions at the time of the observation. 11 � I I I � � I I III I I I I �i I i Iff i I i IM I I I I : v- 111 0 a . Sincerely, Anchor Engineerin Inc. am =# t "aj ef C 0 29.3.5 17 STREEr, DENVER, CO 80211 0 303-783-4797 0 303-83#-9133 VAN 0' OF ®! #<» »<l� 2 », «: ;■ « !2 19 M PI 0 « t t ■i t •< $M ? :91<w# » !£l�x ? <: < ;* !m a+ a we ©t t ■� ;»2 - � - -w.. .t? °■ Li yT- 4&< y ©!-! 33278 } � ` �� } .� O A 2 � :\ > #! , *«» » +,E ENGINEER \\�ja. B EAM AND f R /# «, S t . ■ a. ; .. ' In v e s t i ga ti o n ` y 4 133 FAX 3430 Ward f $ d 4!#140423 Wh eatridge, CO Complete all information on BOTH sides of this for S q. FULF Eltu's � � Gallons Amps Sq uares Other ,. City! o 69 1 cc r Wheat,�'(IW Plan Permit # P hone: Address; City, State„ s Elec trical: P lumbing , vertical; City License # City License # City Liven Revs time of a ) . Squares "tip` Gallons �.�� Amps . .�.- - Sq Ft —_v- .w_.__._ ♦ A ♦ CITY OF WHEAT RIDGE �-r Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 235 -2857 Fax INSPECTION NOTICE Inspection Type: ;TAM2 ° 7A/SP, Job Address: Y;�o Permit Number: - PA'6f dg. , 11 nr:r A A- Acss X31 � 7_w/ VA A" z�oo.i 1 4 _ 'To 5 •- 23s S'c> f ❑ No one available for inspection: Time <2 = '� AM/ Re- Inspection required: es No When corrections have been made, call for re- inspection at 303- 234 -5933 Date: -O / Inspector: >r° r DO NOT REMOVE THIS NOTICE )n We Inspection Type /21/P 45W/­ Job Address JY0' alfA,9 RP Permit Number A&VIoF Pon'r r'05 AMM 7 eW E-D o No one available for inspection: Time Re-Inspection required: No When corrections have been made, call for Date: inspector: DO NOT REMOVE TH • MIVIFram ection at 303-234-5933 S NOTICE DEPARTMENT OF PLANNING AND DEVELOPMENT = BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number Date 12707 8/29/01 Property Owner : Property Address : 3430 WARD RD Phone : 785-3089 Contractor License No. : 20305 Company : Havenar Home Improvement Phone : 853-4745 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby ceM1ify that the setback distances proposed by this permit application are acwrete, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all wnditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge oqClinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED'--DATE'j~ Description : APPLY MODIFIED TORCH DOWN ON FLAT ROOF Construction Value : $900.00 Permit Fee : $35.70 Plan Review Fee : $0.00 Use Tax : $13.50 Total: $4920 Use '~C BUILDING DEPARTMENT USE ONLY ~s SIC : Sq. Ft. . ...a-xi.e~r.u~+a Approval µ Zoning : 4""~~i ....,.~~r,~ Approval : Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company : Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : (1) This permit was issued in accordance with the provisions set forth in yopur ap0lication and is subjecl to the laws oF the State of Colorado and to the 2oning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the Ciry. (2) This permit shall expire if (A) the work authorized is not commencetl wtlhin sixry (60) tlays from issue date or (B) Ihe building authorized is suspendetl or abandonetl For a period of 120 tlays. (3) It this permit expires, a new permi[ may be acquired for a fee of one-half the amount normalq required, provitled no changes have been or will be made in the original plans antl specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or rf suspension or abandonment exceeds one (1) year, full Iees shall be paid for a new permit (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contrector shall notiry ihe Builtling Inspector hventy-four (24) hours in advance for all inspedions and shall receive written approval on inspedion card before proceediing with successive phases of the1'ob. (s) The issu of a permit or the approval of drawings and specifcations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the tli g coqes oEWy other ortlinance, law, mle or re9ulation. Chief Building o WHEqT ISEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BiTII.DING INSPECTION LINE - 303-234-5933 Date: ~ o CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE C~C ORA~~ WHEAT RIDGE, CO 80215 -(303-235-285~ ~~~UCAd ION ProperiyOwner:2£,~-iz2bc PropertyAddress: 3143o 21~ Phone: S° ' 2 9'> ComPanY: Phone: ' 303 &S 3~ OWNER/CONTRACTOR SIGNA'CURE OF UNDERSTANDQiG A[VD AGREEMENT I heroby cer[ify that the setback distances proposed by this peanit applica[ion aze accwate, md do not violate applicable ordinances, niles or regulaflons of the City of Wheaz Ridge or wvcnants, easemenh or restrictions of rocord; that al1 measuxemenis shown, md allegations made are accurate; that I have read md agree m abide by atl conditions printcd on this application md thai I assume full responsibdiTy for eomplia¢ce with Ute Wheat Ridge Building Code (U.B.C) md all other applicable Wfieat Ridge Ordinances, for work under this permit. - (O (CONTRACTOR ATE SzY Descriprion: AP,q Y .~'/ac)• j o2c ~a ho,.-,J Construction Value: Permit Fee: Plan Review Fee: Use Tax: TOt31: ,-IAr ko ' o~ BUII.DING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Contractor License No.: Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expirarion Date: Approval: Approval: Approval: (1) 17tis pwmit was issued in accordance wiih the provisions set forth in your application md is subject to the laws of the State of Colarado md to the Zoning Regulatloas md Building Codes of VJheat Ridge, Colaado oc my other applicable ocdinences of the Gty. (2) 1tis peemit shall exp've if (A) the work authorized is uot comme¢ced within siaty (60) days from isme daze oc (H) the hLiilding aufhariud is suspwded or abmmdoned for a period of 120 days. (3) if ekus peemit exp¢a, a new peimit may be acquired for a fee of one-half tlie emount nomaLLy required, pmvided ¢o changes have been or will 6e made iu tLe original plans md specifiwCons md any suspensioa orabando¢menthaz notexceededone (1) year. If changes havebeen oe ifsuspeosio¢ or abendonment exceeds one (I) yeaz, CuII fees shall be paid for a new peimic. (4) No work of any maoner shall be done that will change the ¢atural flow of wacv causing a drainage problem. (5) Co¢tactorshall noffyNeBuildinglnspectortwmty-four(24)hoursinadvancefocallinspectionsandshallreceivevrtittenapproveloninspectloneazdbefore proceedingwithsuccessivephasesofthejob. - (6) The issuance of a peemit or the approval of drawings and apeci5cafions s6a11 uot be covstrued to he a pelmit for, nor an appmval of, any violation of the provisions of the building codu or any other oxdinance, law, nile or regulaGOn. Chief Building Inspector