Loading...
HomeMy WebLinkAbout9965 W. 34th DriveCITY OF WHEAT RIDGE -A Building Inspection Division (303) 234-5933 Inspection line '(303) 235-2855 Office e (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: V- �V-�� wA e- kV \ ") Y�, � Job Address: _UACD c;;- 1-i ECi 0/11 - Permit Number: N Y" Z_ )95, Ck k/ k2/1 r 1( -A/ Ll No one available for inspection: Time A� AM/PM Re -Inspection required: Yes No! - When corrections have been made, call for! re -inspection at 303-234-5933 Date:_� VA—Inspector: j DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE` Building Inspection Division-'} (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929Fax INSPECTION NOTICE Inspection Type: Job Address: fi Lf 3��P-A Permit Number: -41 7 Jr O 4 !f Ko "10 A f r -✓ r, i P f - ^ � •...1 i .� i 6: s n 1"� �S"* �" ^ � rly✓ 4 r; �� r d _ �: , ��i ❑ No one available for inspection: Time )pm Re -Inspection required: , Y °` No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: ' Lxv tt ®O NOT REMOVE THIS NOTICE City of W at idge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Permit Extension Request Form Permits expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days may be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. Please complete this form in its entirety and submit to the Building Division at permits( 6.wheatridge.co.us or fax to 303-237-8929. Party requesting permit extension: Jaimie Davis Permit # 2017-06354 Phone # 714-598-5999 Property Address: 9965 W 34th Drive Email Address: jaimiedavis@mac.com Reason for extension request: This projet has extenuating circumstances resulting in a need for additional time to complete. Litigation against the builder has resulted in a work stoppage that lasted most of last year. Now we are sheduling a mediation so that could be resolved soon. As of February, the project is now back on track for progress quickly until completion. (It also didnt help that I got diagnosedwith stomach cancer and thatcaused me to take e eg ot Apri for treatment and I am doing alot of the work under a homeowners permit. Number of days requested: 180 days from current expiration date of April 18, 2019 Printed Name: Jaimie Davis Signature: Date: March 21. 2019 For office use only This request has be ,A roved 11 Denied Approved by: www.ci.wheatridge.co.us Extended until: Date:3_12l I I q i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ) a Job Address: q(16_�-) V �0,r1 b,-. Permit Number: 2 01'70L I y ,k -w � ❑ No one available for inspection: Time=ANJ%PM Re -Inspection required: Yes ;No kL When corrections have been made, call for re -inspection at 303-234-5933 Date: I,[ /Dm Inspector:- lr..E Irl Pfi� DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Addition PERMIT - 201706354 PERMIT NO: 201706354 ISSUED: 10/18/2017 JOB ADDRESS: 9965 W 34th Dr EXPIRES: 04/18/2019 JOB DESCRIPTION: Residential addition: 1271 SF conditioned space and 628SF garage. Adding garage and utility room to first floor,(270SF) and master bedroom bathroom and bonus room (1001SF) to second floor. Hi efficiency wall panels "Sips", adding ductless wall hvac unit. Sewer and water to be hooked to existing system. Covered current porch to be expanded 313SF over existing patio. Revision: Revised structural drawings received $0.00 valuation. *** CONTACTS *** OWNER (303)237-2448 BIG SKY PARTNERS GROUP LLC SUB (303)513-7665 Andrew Dupree 170635 Colby Plumbing SUB (970)274-4310 Matthew P. Heffernan 150202 Electrical Systems Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 135,421.20 FEES Total Valuation 0.00 Plan Review Fee 568.39 Use Tax 2,843.85 Permit Fee 1,364.25 Engin. Review Fee 150.00 ** TOTAL ** 4,926.49 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. As part of the foundation inspection and PRIOR to the placement of concrete and before proceeding with any further construction, a completed, signed and sealed, Foundation Setback and Elevation Certification shall be submitted to the City for review. The certification form shall be fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating that the foundation was constructed in compliance with all applicable minimum setback and elevation requirements of the City. For one- or two-family dwellings, the first twenty-five feet (25&#39;) of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. A right-of-way permit may be required; contact Public Works Department at 303-235-2861. Prior to issuance of a CO, 2 tree(s) shall be planted within the front setback. In addition, no less than twenty-five percent (25%) of the gross lot area and no less than one hundred percent (100%) of the front yard shall be landscaped. Landscaping removed or damaged during construction must be replaced prior to final inspection. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development Code. All landscaping shall ve installed in accordance with the approved landscape plan prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 125% of the cost of the installation shall be required. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further a that I am legally authorized to include all entities named within this document as parties to the work to be performed d that al w to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. nam of OWNER or CONTRACTOR (Circle one) Date This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This permit shall expire 5 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date o36f expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. If this permit expires, anew permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or grant' of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any appy e code or an rdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat R.0ge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permits(a)-ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Add to Permif #i�' / 0 63W Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Spy, P(' J Property Owner (please print): �q l l Q_: 0,� I S �cfw— U � Phone: -11 �� S "1 ' SqI Property Owner Email: G ►r''� ► e t�ti' i m Ct L m Mailing Address: (if different than property address) Address: City, State, Zip: rvIA Submitting Company I�tY1 . o�z=�e�2 / Te ✓� a Vk Contact Person: I o o vii E DA- j,S Phone: Contractor: Contractors City License #: Contractor E-mail Address: r1j /n Phone: Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: si-rv�i-v�il ✓)�lnP�� U„�ns /rl com if-e✓I+ GY,J PVvLIII z gctev,,ak pJclns', /j)✓ ex-al-opb, 51 yi-u c4 DI' bv1 S vv c, l W1-�h ��f /l'�� b��� rvt S 5 �� '�'�' d di of ofi fGi [C v /a IL'oF- Loi0 d sGI2cl P, Sq. Ft./LF Amps Btu's Squares Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) $ /v / A 0"'NER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (HORIZED REPRESENTATIVE) of4 WNER (CONTRACTOR) PRINT NAME: JA I Vv1! C' 1 S SIGNATURE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY DATE: Ji -23-19 OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of' �C(AIXIONHYDtvitor\UNi I heat f" L a�- City of Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 FOUNDATION SETBACK AND ELEVATION CERTIFICATION This form, including the Exhibit on the reverse side, must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This Certification must be submitted for review and approval prior to the placement of concrete and before proceeding with any further construction. DATE: 1.0-23-17 PERMIT# ADDRESS: 9965 West 341 Ave LOT 15, BLOCK , HILLHAVEN SUBDIVISION I hereby certify that the elevation and location of the structural foundation for the above property described above has been measured by me or directly under my supervision. The foundation setbacks and elevations for all building corners as stated herein have been found by me to be in compliance with all municipal setback and elevation requirements, and all civil engineering and Building Permit construction plans as approved by the City of Wheat Ridge. The MINIMUM SETBACK DISTANCES from the property lines have been determined to be: FRONT: 30.55' REAR: 40.2' SIDE: 15.1 to East The MINIMUM ELEVATION has been determined to be: SIDE: 15.1' to West The above measurements have been determined on the following location: Check only one): Top of foundation prior to placement of concrete (NAVD88). XX Top of proposed foundation subsequent to placement of concrete The setback and.elevation measurement locations are identified on the attached exhibit. d�2-z--- Signed v Print Matthew Huffman Date 10-27-17 Professional Surveyor FOR OFFICE USE ONLY Approved by: la,;pecNrr Date www.ci.wbeatvidge.co.us Rev IM (Surveyor's Seal) EXHIBIT i ' • • • NOT TO SCALE 1 1 LOT 15 1 I 1 I 1 40.19 1 I 1 1 I 1 1 I 1 1 I 1 1 I 1 1 15.10 1 1 1 15.14 1 1 1 I 1 1 1 1 I 1 1 I 1 I 1 • • 30.55 • � 1 •• I `wE�r 4 60, RICH; NOTICE TO SURVEYOR: 1. Elevations shall be shown for ALL foundation corners. ?. Foundation corners with minimum elevation and setback distance shall be identified. 3. Drawing must be property oriented (North = top of page). 4. Show the roadway in front of the property. 5. 1f drawing is to -scale. provide the scale. If not to -scale show as N.T.S. 7` i CITY OF WHEAT RIDGE Building Inspection bivision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 303-p Stv�CH'A lng Job Address: CM 5- VMA b�, Permit Number: 01,7 3 5-4-/ i ❑ No one available for inspection: Time 1'40 I'i%1f PM/ L Re-Inspection required: YesCV�o When corrections have been made, call for re -inspection at 3a3- -5933 Date: I � q/ 16—Inspector: DO NOT REMOVE THIS NOTICE City of Wheat i9lei COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29`h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Permit Extension Request Form Permits expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days may be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. Please complete this form in its entirety and submit to the Building Division at pennitsgci.wheatridge.co.us or fax to 303-237-8929. Party requesting permit extension: -J A\ M � A V I S Permit # 2c 17 - 0 6 3 j `( Property Address: 3 q t 1 0 ri 1,{ Phone # Email Address: v Reason for extension request: /V QIL.nJ p fi,_-tr �0 CO/�-t,JJ�, I /Ssves res ulr� 6 bC._-y'Ir / -P A 9 /dl " d - Number of days requested: 18,0 1l M de & or, eX-,OlrQ bp;., Printed Name: -,%A I M IG 1)A-,, r S" Signature Date: For office use only This request has been:App ved Denied Extended until:"/ — �ff/ 3 Approved by:4 Date: qkl1ool\� www.ci.wh eatridge.co.0 s f� h � �afeS i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F� 3/ oe-C% Job Address: qq5 3gtl( r Permit Number: ow 7"-) Ll No one available for inspection: Time + fu A Re -Inspection requiredYes ,No When corrections have been made, call for re-inspection/at 303-234-5933 Date: , /� - X Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: q 'e�- i a ---?) Permit Number: -7 :3 ❑ No one available for inspection: Time 9 AM/PM,�` Re-Inspection required: Yes ,"No When corrections have been made, call for re -inspection at 303-234-5933 a 1 r Date: r Off " . Inspector: DO NOT REMOVE THIS NOTI i _ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: i02 1200 -µ lk CT_ Job Address: �i Permit Number: '00 1306�50+ ❑ No one available for inspection: Time Re -Inspection required: Yes No When corrections have been made,II re -inspection at 303-234-5933 t Date: IO &714_ Inspect r`` { DO NOT REM THIS NOTICE -7, i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Re -Inspection required: i Yes �No : ` When corrections have b Date:-/ made, call for nspector: 303 -234 - i CITY OF WHEAT RIDGE �� Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax 0 INSPECTION NOTICE Inspection Type.(,�,� _ ,V `r Job Address: �/ 5 tA/ e ❑ No one available for inspection: Time()/-"/ AM/PM � 1 Re -Inspection required: YesNo When corrections have been made, call for re -ins ion at 303-234-5933 1� Date: )Q �4_/_ " % Inspector: G✓ r A i CITE( OF WHEAT RIDGE �(303) Building Inspection Division11 J'd(303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: �J 3 Permit Number: >01766 - TIE_ 3 r _T <--� T. . No one available for inspection: Time �PM LJp Re -Inspection required: Yes Nof �.r When corrections been made, call for re -inspection at 303-234-5933 Date: 40, 0' �7 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Anll A je-' qqbs U) .3(_ Permit Number:D�7U(,U5 n (0-,26.17 Ll No one available for inspection: Time M( PM Re -Inspection required: (Yes) No When corrections have been made, call for re -inspection at 303-234-5933 Date: /0';261, ZZ Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTIOON" NOTICE Inspection Type: 10 -31 T G I Job Address: Permit Number: i �- I ❑ No one available for inspection: Time Re -Inspection required: Yest No When corrections have been made, call for re -inspection at 303-234-5933 Date:Inspector: 6� DO NOT REMOVE THIS NOTICE 1k I City of Wheat Ridge ® Residential Addition PERMIT - 201706354 PERMIT NO: 201706354 ISSUED: 10/18/2018 JOB ADDRESS: 9965 W 34th DR EXPIRES: 10/18/2019 JOB DESCRIPTION: Residential addition: 1271 SF conditioned space and 628SF garage. Adding garage and utility room to first floor,(270SF) and , master bedroom bathroom and bonus room (1001SF) to second floor. Hi efficiency wall panels "Sips", adding ductless wall hvac unit. Sewer and water to be hooked to existing system. Covered current porch to be expanded 313SF over existing patio. *** CONTACTS *** OWNER (303)237-2448 BIG SKY PARTNERS GROUP LLC SUB (303)513-7665 Andrew DuPree 170635 Colby Plumbing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 135,421.20 FEES Total Valuation 0.00 Plan Review Fee 568.39 Use Tax 2,843.85 Permit Fee 1,364.25 Engin. Review Fee 150.00 ** TOTAL ** 4,926.49 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. As part of the foundation inspection and PRIOR to the placement of concrete and before proceeding with any further construction, a completed, signed and sealed, Foundation Setback and Elevation Certification shall be submitted to the City for review. The certification form shall be fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating that the foundation was constructed in compliance with all applicable minimum setback and elevation requirements of the City. For one- or two-family dwellings, the first twenty-five feet (25&#39;) of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. A right-of-way permit may be required; contact Public Works Department at 303-235-2861. Prior to issuance of a CO, 2 tree(s) shall be planted within the front setback In addition, no less than twenty-five percent (25%) of the gross lot area and no less than one hundred percent (100%) of the front yard shall be landscaped. Landscaping removed or damaged during construction must be replaced prior to final inspection. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development Code. All landscaping shall ve installed in accordance with the approved landscape plan prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 125% of the cost of the installation shall be required. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thisyermtand perform thework descbed andapproved in conjunction with thispertIfurtherattest that I am le ally authorized to include aentities named within this document as parties to the work to be performed ancthat altobeperrmed isdisclosed in thisdoment and/or its' accompanying approved plans and specifications. Signature' -of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of' the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or re n of thisjurisdic ion. A pro al of work is subject to teld inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11. 9PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of _y,:�rWheat Rj,jge COMMUNITY DEVELOPMENT Building & Inspection Services Division �f 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits cDci.wheatridge.co.us FOR OFFICE USS ONLY Date: � ' Plan/Permit#/"U j Plan Review Fee• Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 1965 W 3y pal ve wheaf !'i d4G, co.?00:3 3 Property Owner (please print): _)ptlm ,F- I)Av;r, &6 StcY PAk'rA _S 6AovlPhone: 7/9.519-599,7 Property Owner Email: �IA �M�c�av�'s a Mac -c m Mailing Address: (if different than property address) Address City, State, Zip: Architect/Engineer: CRowAu �,j,� EngJAN�41w9 o Mack ?3_XA Architect/Engineer E-mail: Marko- Crown lad(s.. c.om Phone: 9 7o - `] 72 -23 9y Contractor: TAe- .zu,N 6rvvo, _,,,, Brya,,, Labvd.a 8ovtd'e.t Contractors City License #: __rN progress : Cots► -i2 - Doo, 9 Phone: 303- l - O!D/ Contractor E-mail Address: i cow, i, e.�tafinar%. cor, Sub Contractors: Electrical: Ekt4l ic-1 SVS' tc `s W.R. City License # ?.ry proLe,s5 Other City Licensed Sub: City License # Plumbing: Colby Pkmb l'.J3 W.R. City License # Tn O o ce ss Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL 'RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING 13RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) RCs'te^J-HA, I actAlhan of-ardga, lavndry and r.tas4ctbec1vva m utkt4►ed 4o ex%sh"a 5twc-�fvrc• Ektsk�.� Aire -w is c.vrrer%+ly a carPor+ . 4jeavel driveway, APP(" AKC.CS -fo r�clV.,e L.qh ewc4¢ncy Wast%ejc 4-6"cdL. C.owsi-wek-D' + 4o b., SIPS"Panels + r -06f W94k k:qk 1A5vta.iton p.oP. 11;VS. C)VC-(25;S Wtilt tiVAc line will bt. VScd 1n5k-cckd of t.(VAC. Sfrs-1,r^ 4o red.vC$ indoor al/erc�¢ of • r►+ore cnc r9Y a lrj'eA,24. S# -u A,,L F w&4<A, }o b e k aoKed 4-o r9 sys4tA4— Cove.r*td Gvrrent porch -s b- Q-xpaHd.ed over ClcIS(,;%q IIPQ-o. Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ b19, oDo OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNS(CONTRACTOR) or (AUTIIORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): cry I., `b� DATE: 1 % h-7 DEPARTMENT USE ONLY 5,00 sr ZONING COMMMENTS: C� �` OCCUPANCY CLASSIFICATION: Reviewer: v �,} �� t (y��$ / f � = Gates-� - `.�� 'ft' 4� se BUILDING DEPARTMENT COMMENTS: (� 1 ��� -L,,3 V Sko , � tt101 Vd ISI o /sf: Reviewer. NUA 5 �l )9L)eL,16 Wokl667 C OM"ON7-5= l) D1�2£57I' 202F DQA94 45 59CINiV 04 RPW- M V4 V 71 i 7 L -/NF --D SIVE ) .Aq Tn PPM6GT ADJAC�47- ar-, F�zoM STM,a.µWA-ri R- aUNofr-_ 2) A GRADltil6G��'Ti�/cA� ! 1277 I ANO AN ir.G MAP 514AL- - 9E F-EQD. FR/+Dg Tcl� G.o, -P Ej59pf57 Ppcm� Building Division Valuation: $ City of SINGLE FAMILY/DUPLEX -;" ���� ���� BUILDING PERMIT APPL 1' ►� ►► ► ► c WORKS KATION RE MEW Date: /!7 Location: 99ro� W, 3� Op-l�/ ATTENTION: BUILDING DIVISION I have reviewed the submitted application documents to construct a A1,5& Atminc/ located at the above referenced address. Please note the comments checked below. 1. Drainage: a. Drainage Letter & Plan required: Yes No b. Site drainage/grading plan have been reviewed and are: -ZOK �; refer to stipulations. 2. Public Improvements required & to be completed with project: a. street paving/patching: Yes --1(- No Completed b. curb & gutter: Yes No Completed c. sidewalk: Yes --.k/— No Completed d. Other (specify): Yes No Completed For items not constructed, the amount of funds taken in lieu of construction: $ 3. --kl— Does all existing roadway/alley R.O.W. meet the standards of the City: —/— Yes No If not, what is required? If R.O.W. is required, has the deed been received: Yes No (see Note below) NOTE: All deeds must be reviewed and approved prior to issuance of the Certificate of Occupancy. 4. V, APPROVED: The Public Works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated requirements and/or attached stipulations. — At- Y A& &^.� R /7 /17 Signature Mark Van Nattan Date 5. / NOT APPROVED: The Public Works Department has reviewed the submitted material and does not approve this Permit Application for the stated reason(s): Signature Mark Van Nattan Date 42 1E*Z Z "Tb PN! C�nAJA 1Wr-G iW 'Rao -i /A/90--& 7. A Grading Certification Letter from the Engineer -of -Record accompanied by an Improvement Location Certificate (ILC) shall be required prior to the issuance of the Certificate of Occupancy. 8. NOTE: ANY DAMAGE TO EXISTING PUBLIC IMPROVEMENTS ASA RESULT OF PROJECT CONSTRUCTION SHALL BE REPAIRED PER ROW CONSTRUCTION PERMIT PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. Rev 04/2016 FEE CALCULATION WORKSHEET Project: Davies AdditionDate: 9/11/17 Address: 19965 W. 34th Drive By: MVN Item Description Quantity Unit Unit Cost Item Cost 1 Excavation & Embankment Earthwork — rough grade — 7.5' wide 0.83 SY $ 5.98 $ 4.98 Earthwork — fine grade — 7.5' wide 0.83 SY $ 1.23 $ 1.03 2 Reconditioning Reconditioning & proofrolling — 7.5' wide 0.83 SY $ 1.97 $ 1.64 3 Sidewalk Concrete sidewalk — 6" thick and 5' wide 0.56 SY $ 43.02 $ 23.90 4 Curb & Gutter Vertical curb & gutter 1 LF $ 20.64 $ 20.64 Total cost per linear foot $ 52.19 FRONTAGE LENGTH W. 34th Drive (Property line less drive cut) 78.01 LF Cost of sidewalk only $ 2,262.00 Cost of curb and gutter $ 1,808.82 Total $ 4,070.82 Note: Lengths from Architectual Site Plan. Actual lengths determined by survey will affect costs shown in this estimate. Fee Calculation Worksheet - 9965 W 34th Dr.xlsx City of at Nid 6IIC Wolzxs .�S!ge City of Wheat Ridge Municipal Building 7500 W. 29'h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 PUBLIC WORKS DEVELOPMENT REVIEW FEES Date: Location of Construction: IT 17 05 W, :�34 41 0221 V Purpose of Construction: v�ihlr�t� r= FA M /LY Single Family _ 1z Commercial Development Review Processing Fee: ................................................ $100.00 (Required of all projects for document processing) Single Family Residence/Duplex Review Fee:. ...................... CommerciaUMulti-Family Review Fees: • Review of existing or minimal technical documents:........ • Initial review' of technical civil engineering documents (Fee includes reviews of the 151 and 2nd submittals):.......... e Traffic Impact Study Review Fee: (Fee includes reviews of the 151 and 2nd submittals):.......... ® Trip Generation Study Review Fee: .................................. ® O & M Manual Review & SMA Recording Fee...... ........ I..... $50.00 ........... $200.00 ........... $600.00 ............... $500.00 ........ $200.00 ............ $100.00 Multi -Family ' Each Application will be reviewed by staff once and returned for changes. If after review of the second submittal changes have not been made to the civil documents or the Traffic Study as requested by staff, further reviews of the Application will be subject to the following Resubmittal Fees: ® Resubmittal Fees: 3rd submittal (% initial review fee) :.............. 4th submittal (full initial review fee):....... All subsequent submittals: ......................... (Full initial review fee) ......I .................. $300.00 .................................... $600.00 ............................ $600.00 TOTAL REVIE`V FEES (due at time of Building Permit issuance) $ PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE ADDITIONAL LICENSING AND PERMITTING FEES REQUIRED FOR CONSTRUCTION OF IMPROVEMENTS WITHIN PUBLIC RIGHT-OF-WAY. )k %% NN., i.�+ huan idgexo.us Rev 12/12 City cif hcat j `idio PU111IC WORKS City of Wheat Ridge Municipal Building 7500 W. 296 Ave. Wheat Ridge, CO 80033-8001 P: 303.235-2861 F: 303.235.2857 NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATED: ADDRESS: T3 &,_G—N/ 3.¢4-1 Perla Dear Contractor: In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as determined by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the existing condition(s) of the public improvements at this address. If you have any questions, please contact me at 303.235.2864. Sincerely, David F. Brossman, P.L.S. Development Review Engineer CC: File "'Iv.ci.wheatridge.Co. us Rev 2108 RESIDENTIAL Building Permit - Plan Review Worksheet Address: q1 q (0 5- 0) S �4 %);, Lot Size: / , l q sq. ft. Property in the flood plain? Y(,,u If yes, notify PW Floodplain Administrator and add surveying condition FLD Zoning: - Lot Width: % O Y ft. Rev. 09/2017 Subdivision: Related Cases: tl "v -e, d/ �NJ' Any conflict? (Y/N) Type of project (applicable survey conditions in parenthesis): Maximum Lot Coverage: Z5 Existing Improvements (footprints): House: / Z i S sq. ft. Shed: / / sq. ft. Detached garage: sq ft. Other:_ sq. ft. �4 % 3 2 Z- 3 sq. ft. Proposed Improvements (footprints): House/addition: f l S sq. ft. Shed: // sq. ft Detached Garage: sq. ft. Other: / l V 3 sq. ft. Total Existing r L '4- sq. ft Proposed+Existing sq. ft Lot Coverage I q, % Lot Coverage 3 , % P � Required Setbacks: FR S 1 S l R r' Provided Setbacks: FR S S R For additions or new construction, is the structure within 2 feet of minimum setbacks? If yes, add surveying condition FND. Maximum Height: 3,5- ft. Maximum Size: sq. ft. Proposed Height: t�2E 1 ft. Proposed Size: sq. ft. Does the bulk plane apply? (Y/N) n c) If yes, does it meet on all sides (Y/N): FR S S R (See 26-642 and 26-120.C.1 — applies to all single-family structures (new, addition, accessory) in R -I C and R-3) Parkland Conditions Does the permit result in a new dwelling unit (new structure or conversion from non -res use)? If yes, have parkland dedication fees already been paid (eg with a previous land use approval)? If fees are owed, add condition PFEE, notify owner, notify building division, enter fee amount in ADG. Rev. 09/2017 Streetscape Conditions Does the permit result in any of the following conditions? ❑ Construction of new roads ❑ Platting of new lots ❑ New development , Additions that increase gross floor area (not just the footprint) by 60% or more (proposed floor area — existing floor area ) / existing floor area = % increase If any box above is checked... For SF/DUPLEX—Is there existing ❑ Curb ❑ Gutter L15 -ft+ sidewalk adjacent to the property? If curb, gutter or sidewalk is missing, streetscape construction or fees -in -lieu will be required. MULTIFAMILY—Does the frontage meet current city standards? If not, streetscape construction or fees -in -lieu will be required. Fees -in -lieu of dedication or construction are due at the time the permit is issued. Ac ces Conditions (apply to all new driveways, garages, additions, or new homes/units) For one and two-family dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. ❑ For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer than 25' to any property line, except when used as joint access for two or more lots. ❑ In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. ❑ One and two-family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. ❑ For all uses, one access point per property is permitted. Landscaping Conditions (apply to additions and new dwelling units) ❑ For one -and two-family dwellings, one tree for every 70 feet of street frontage is required. Frontage of lot % D : - width of driveway / 70 = (round up for required trees) Street trees required: 02- Street trees provided: 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance of C.O. In the event that landscaping cannot be installed due to inclement weather prior to the issuance of a C.O., an escrow agreement with financial guarantees may be allowed to ensure future installation. 125% of the cost of the proposed improvements will be required with the agreement. These funds will be reimbursed back to the property owner or contractor once the improvements are in place. Dwelling Unit ❑ Not approved as an independent dwelling unit. City of 4- � %V"W Anew-wil-Ridge Cris' OF WHEAT R=E BuRDM AND INSPWMN SmvicEs DmsjoN 7500 W 29th Ave Whew Ridge, CO 80033-8001 p, 303.235.2855.f 303.237.8929 9 TINT 4 =11M !."l is ILII A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed, Date: It, 2-017 1k, Project Address: Project Type/Description: Signature of Firm indicated below and do, for review and approvab FT'A 1 -77 t 4 th J^ Y'3 documents: rke4ito.OI*P 4-0 6� , am a duty authorized representative of the agency W -below, hereby acknowledge receipt of documents necessary indicated above. • Wheat Ridge Fire Protection • Arvada Fire Protection • Wheat Ridge Water District • Consolidated Mutual Water District • Valley Water District • Denver Water Agency Notes: o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District )s< Westridge Sanitation District o Other Signature. '" Date: 670116IZ4-'�17 7 -7(Agency Representative) I II City Of Y ' b" 6 PF CITY OF WmF.AT RIDGE BUILDING AND INSPECTION SERVICES DIVISION 7500 W 29th Ave Wheat Ridge, CO 80033-8001 p. 303.2351855.f 303.237.8929 Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processe Date: „®$ 14 1 -7 1�4 Project Address: 4 + 5 4 *°` }t2 it+s LAjb&r r 800,73 Name of FirmAndivd I sub ting documents: I;40.4 es C",,r Project Type/Description: P&ehiil a4a(:16!3 Signature of Firm indicated below and i•� b�, am a duly authorized representative of the agency n e below, hereby acknowledge receipt of documents necessary indicated above. o Wheat Ridge Fire Protection o Arvada Fire Protection o Wheat Ridge Water District )6 Consolidated Mutual Water District o Valley Water District o Denver Water o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District o Westridge Sanitation District o Other Signature f Date. (Agency Representative) i 'I* � 4 4� 14 vPI City of iRrM�h6at �idge MMUNITY DEVELOPMENT Project Address: 99 G 5 tv 31/'6' Permit #• J?v, %f' n9 Contractor: 2N 6,IV e4 'Lac-, Electrical Contractor Company Name:,C1 YA=e'tI�JAVI)hone #: 2 70 2 7,'-tl3l6 State License #• 6C-QQQ&yam Master#: lir- m o a 7 Z Nil-., SIA 37141drimi 1 i' • t I Plumbing Contractor I Company Name: Phone #: State License #: Master #: 'heat Ridge License #: Signature of Authorized Agent bate I Mechanical Contractor I Company Name: Phone:, Wheat Ridge License #: Signature of Authorized Agent Ehft *Tids apptimdon most be Aped by a wh sub -cm r eantinubg the ume . City of "��►Theat�Z�d�e �naurrrr5r D�rx�r�T SUB -CONTRACTOR AUTHORIZATION FORM Pkqject Addrem: #jiq j,� Penult #: �vtYdin9 Q40"COnuadm7. Orvan c: DN -f 2- U®o1i e_L4SS Flectrical CmtIactor Camey lame: Phone #: State License #: Master #• Siguatwe of Aufhor zed Agent Date tit i if 1ttSi .:� it js :r�r. s ret t' tis �e i 177"'.7 rile ::s+ T s'sr t :rt :ret Isis`e V W771' ' e • «Zt 7 6—/,0-17 .Date .-il i t ' 1Au&odwdAgent Date *This appb a m mast be by +each u&e=&&eftr eoubuing the an& 2013080777 712/2013 2:52 PM PGS 1 $11.00 DF $23.00 Electronically Recorded Jefferson County, CO Pam Anderson, Clerk and Recorder TD1000 Y PERSONAL REPRESSENTATYVICIS DEED (sWO) THIS DRED is trade by Scott A. Westover as Personal Represaatative of the Estate of Fayette Roue Westover, sikhs F.Roes Westover, s1Yla Ran Westover,Deceased, Grantor, to BIG SKY PARTNMS MOUP, LLC. ANEW MLXItO LIMITED LIABILITY COMPANY, Gmatee, whosa legal address is 4955 WEST 34TH DRIVE, WHEAT RIDGE, CO $0033, of ft County of 7d%rson0024 Cglo* 02,0/.? 45W WHEREAS, the decedent died on the date of.4�ill H, M ��, and Mator was duly appointed -Personal Representative of said Estate by the District Court in and for the County of !ejl'ersop, Stats of Colorado, Probate No. IMA30111, an the datr of (prii 11, 2013, and is .now gaa]Twd and acting in said capacity. NOW THERBFORJ , pursuant to the powers conferred upon Gmtor by the Colorado Probate Code, Cirantor does hereby salt and convey unto Grantee for and in consideration of Two Hundred Thirty Thousand Doltary ($230,000.00) the fnitowing described real property situate in d1c County 0( 10&01013, State of Colorado: LOT IS, MLL RAVEN 9UBDMSION, COUNTY OV JEMRSON, STATE OF COLORADO also imownby street and number an. 9465 WEST 34Tff DRIVE WHEAT RIDGE, 00 80033 assessor's Schedule: 021031; Parcal tD: 39-272-14-014 With all appurtenances; As used herein, the singular includes the plural and the plural Llai singular. 1:atecuterd _„ 2413. i�war F wumentary Fee ,3 e 00 Sprit I 'Westover, Personal R*asentativa of the Dtate of Fayette Ross Wcoaver, aWa F. Ross. Westover, aWa Rom Westover, Deceased STATE OF COLORADO } ss. COUNTY OF JEFFERSON � The foregoing instr stent was acknowledged before me this A day of t Ih nt l__ 2013, Scott A. Wtsto,= its Personal Representative of the Estate of Fayette Ross Westover, WV& F. Ross Westover, a/k/a Ross Westover, DeoemimL Witness my hand mrd official vealj. _ PAflA LLA NOTARY PUBUC�� STATE OTARYF �oOa�LORA my Commission Expires ianuary 15.2015 Notary Public Name and address of parson trotting newly created Segal description (§35-35-146.5, C,R.S.) Property appraisal system Page 1 of 1 Property Information GENERAL INFORMATION PIN/Schedule: 300021051 AIN/Parcel ID: 39-272-14-014 Status: Active Property Type: Residential Property Address: 09965 W 34TH DR lowner Nam (s) WHEAT RIDGE CO 80033 5763 BIG SKY PARTNERS GROUP LLC Mailing Address: SAME ADDRESS AS PROPERTY Neighborhood: 2406 - BEL AIRE,HILLCREST HEIGHTS, MELROSE MANOR AREA PROPERTY DESCRIPTION Subdivision Name: 346200 - HILLHAVEN Mock Lot Key Isection ITownship JRange lQuarterSection IlLand S ft 0015 127 13 169 1 12894 otal 112894 Assessor Parcel Maps Associated with Schedule pmap39-272.pdf PROPERTYINVENTORY Interactive Map Property Type RESID Year Built: 1956 Adjusted Year Built: 1956 Design: 1 Story/Ranch Improvement Number: 1 u Item Quality No. Carport Average 355 1/2 Bath (2 fixture) Average 1 Bedroom Above GradeAverage 3 Number of Units Average 1 Base Bath verage 1 Adjustment Code JAdjustment S Ft Forced Air Unit Hea 1215 Basement Finish 1441 SALE HISTORY Areas Quality Construction Sqft Carport Average 355 BSMT TOTAL Average 588 First Floor Average M 1215 Covered Porch Average 108 Land Characteristics 04-11-2013 Good View Below Avg. Location Sale Date Sale Amount Deed Type Reception 03-15-2006 0 Death Certificate 2006031509 04-11-2013 0 Letter or Letters 2013080776 06-27-2013 230,000 Personal Representative Deed 2013080777 TAX INFORMATION =2017 Payable 2018 View Mill Levy Detail For Year 2017 2017 Mill Levy Information Actual Value otal 323,700 County Assessed Value otal 25,767 2016 Payable 2017 TB REGIONAL TRANSPORTATION DIST Actual Value otal 274,850 URBAN DRAINAGE&FLOOD C SO PLAT Assessed Value Total 21,878 Treasurer Information http://ats.jeffco.us/ats/displaygeneral.do?sch=021051 09/12/2017 2017 Mill Levy Information ax District 3141 County TB School TB WESTRIDGE SAN DIST TB REGIONAL TRANSPORTATION DIST TB URBAN DRAINAGE&FLOOD CONT DIST TB URBAN DRAINAGE&FLOOD C SO PLAT TB WEST METRO FIRE PROTECTION - G TB WHEAT RIDGE TB [Total TB http://ats.jeffco.us/ats/displaygeneral.do?sch=021051 09/12/2017 2013080777 7/2/2013 2:52 PM PGS 1 $11.00 DF $23.00 Electronically Recorded Jefferson County, CO Pam Anderson, Clerk and Recorder TD1000 Y PERSONAL REPYMENTATIVE'S DRKD (Salo) THIS REED is made by Scott A. Westover w Personal Representative of the Estate of Fayette Rat Westover, aWa F. Ross Westover, AM& Ran Westover, Ilcceaaed, Grantor, M BIG SKY PARTiVM MOU P, LLC, A NEW MIiaLIt~O LIMITED LIABILITY COh3PANY, Chmutee, whose legal address is 9455 WEST 34TH DRIVE, WHEAT RIDGE, CO 80033, ofthve County of hfiorson, and Staof Gq1 WHEREAS, the decedent died on tin dat te afA�--6,36- � and ir}rantor was duly appointed -Personal Representative of said Estate by the District Court in and far the County ofieferson, State of Colorado, ,Probate No. 1,3PR30111, an the lots of dprii 11, 2013, and is now gaali&cd and acting in said capacity. NOW THERFFCIRE, pursuant to ft powers conferred upon Grantor by the Colord Probate Code, {3rasrtur does hereby sell and convey unto Grantee tnr and in consideration of Two Hundred Thirty Thousand Dollars ($230,000,00) the following described real property situate in the County of IclT MR4 State of Colorado: LOT Ts, HILL HAVEN sUaDmsION, COUNTY OF JEMRSON, STATS OF COLORADO also known by street and number as: 996S WEST 34TT4 DRIVE, WHEAT RIDGE, CU 80033 assessor's Schedule: 821051; Parcel ID: 34-272-14-014 With all appurtenances.. As used herein, the singular includes the plural and the pkual tit singular. Executed 2013. Sta+19 DQC 1 Lary Fee nate, .bpMR- "M J Wt I Westover, Personal 11*esentative of the state of Fayette Ross Westover, a.Wa F. Ross Westovei, allds Mw Westover, Deceased STATE OF COLORADO } } SS. COUNTY OF JEFFERSON a Tba foregoing instrmneut was acknowledged bcforo mo this A , of C� 20 i3. Scott A, Westover ata Porsonai Representative of tin Estate of Fayette Ross' 4'N'astover, Sikh F. Rosa Wrstover, alkta 11029 Westover, Dewmad. Wjw" tuy hand and offucW PAMELLA S.'M!' RR1 551ty NOTARY PU'SUC STATE OF COLORADO NOTARY034001619 My Commission Expires.larwwy 15.2015 Notary Public Idatne and address of person creating newly created legal description 038-35-1065, C.R, S,) NJ +�" ¢ rZ W�{.. crfy OF WHEAT RU*E BUTiT)IrIG AND TNSiECfSON SERVICES DMSION 7500 W 29th Arse 'Wheat Ridge, CO 800334001 p. 303.235.2855.1303.237.8929 Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processe Date: $ 3,1 2-017 Project Address: Name of Project Type/Description: Signature of Firm J^ r documents: UA' 1�4t �+avls 'i q 5 at �#�rt c o,,p F .-1.:,1 A .i j--- 4-o 't�' am a duty authorized representative of the agency indicated below and do, b m below, hereby acknowledge receipt of documents necessary for review and approves roject indicated above. Ato=Wppdfieijt d; (Please check one) o Wheat Ridge Fire Protection o Arvada Fire Protection o Wheat Ridge Water District o Consolidated Mutual Water District o Valley Water District o Denver Water Agency Notes: o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District Westridge Sanitation District o Other Signature: Date: 01f61741!'� {Agency Representative) ' City of PF orwh;6 CITY OF WHEAT RMGE $tJUMG AND INSPECTION SERVICES DIVISION 7500 W 29th Ave Wheat Ridge, CO 80033-8001 p. 303.235,2855.f 303.237.8929 Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or pr Date: ---=. It, 12017 Project Address: Name of FirmAndividu su ting documents: JA- I wt i e outs i jam « x t k 1... 'Zj.J Y 4TiVCi+V'• Project Type/Description: 4 A t e T" Signature of Firm 11 t,t`Yt I it 1Vfillk .4• - indicated below and do, by rrI . for review and approv,arojec fSnCy i1L*d: (Please check one) am a duly authorized representative of the agency Fe -below, hereby acknowledge receipt of documents necessary indicated above. o Wheat Ridge Fire Protection o Arvada Fire Protection o Wheat Ridge Water District Consolidated Mutual Water District o Valley Water District o Denver Water o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District o Westridge Sanitation District o Other Signa Date.�1- (Agency Representative) 'AA 'It � I le Iq Ip" City of M�h6at d c,w ip SUB-CONTSUB-CONTRACTOR AUTHORUATION FORM Project Address: 9 q 65 cfJ Permit #; Gem Contractor:or� Electrical Contractor Company Name: 1,O e*6 OWA6 'hone #:!Z 70 State License #: Master #: AA, 6 Ov Z 0 t 7 Signature of Auth&bv6d Agent bate Plumbing Contractor Company Name: State License #: Wheat Ridge License #: Signature of Authorized Agent Phone #: Master #: ! Mechanical Contractor I Company Name: Phone:, Wheat Ridge License #: Signature of Authorized Agent Date *Thk application most be signed by each sub- ent met oar saaaficmriag the same. AA City of "� �eat�idge WCOMMUNITY DELo NT Project Address: permit #: Contractor : IV G,0 /V - / 2- - 0()0 C bllkss 8 [Electrical Contractor Company Name: State License Phone #: #: Master #: Signature of Authorized Agent IPlumbing Contractor Company Name: Q-) I State License #:_Pc,.ter r� 7 U Wheat e License #:7 _ t J SiofAuthorized Agent IM Phone #:.?, ( '-'3 - , 51 Master #: pie J) ()I ZLL0 I Mechanical Contractor I Company Name: Phone: Wheat Ridge License Signature of Authorized Agent IM *This application must be signed by each sub -contractor conftmdag the same. ! A f -� City of A( Wheat jd e COMMUmTY DEVELOPMENT Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owner(s): p, M1 _r_ T� P,y i 5 Project Property: (0 5 W_3 q"— D W huj+ f i t cr C-0 S 00 3 3 Not ri d signature of Applicant State of Colorado } County of c YIN } ss The foregoing instrument was acknowledged by me this 17 day of A!�Jvs � 20 7 by N a ublic JAYMESUE MCRIMMON NOTARY PUBLIC STATE OF COLORADO NOTARY ID # 20154009457 MY COMMISSION EXPIRES MARCH 06, 2019 My Commission Expires 3 /__�2J20�g I f z f: rte, ii f � , , r r ;�,. r i+ , r Ci a � � t F j i 1 A.M I i PLAN REVIEW RESPONSE LETTER 9965 W 34TH DRIVE WHEAT RIDGE, CO 80033 PLAN CHECK # 201706354 8/21/2017 JAIMIE DAVIS 714-598-5999 1. Plan review approval from: Building, Planning, and Public Works Dept. 2. All plans shall be wet stamped and signed prior to permit issuance. Q3. Include the following on the cover sheet: A- G - Done Shown on Cover Sheet 4. Remove Redlines - Done J� Shown on All Sheets U 5. Revise sheet A3 to show new walls as double lines. Show all doors to clarify interior circulation. Show wall separating bonus room from bath. Wall appears to bisect exterior window. - Done. window placement was corrected on A3. Shown on A3 6. Identify vertical direction of stairs. Specify total vertical height. Show handrails. - Done Shown on A3 and SIPS page 2 of 5 section A Q7. Revise sheet A4 plan label from 2nd floor to Roof Plan. - Done Shown on A4 8. Clarify if pergola is new or existing. Done Shown on cover page. /6\ 9. There are two 2/A6 cross section keys on sheet A6. Coordinate on sheets A3 and A4 with A6. Done. Shown on A6. 10. Show the water closet in master bath. Demonstrate 15 inches clear from the centerline of the water closet tot he adjacent finished wall surface and minimum of 21 inches clear in front of water closet. Compartments to be a minimum of 30 inches x 60 inches in depth. - Done Shown on A3. 11. Show the location of the washer and dryer in the laundry rooms. Demonstrate the �--� exhaust ventilation as required by IMC 504. Shown on M1 and M2. PLAN REVIEW RESPONSE LETTER 9965 W 34TH DRIVE WHEAT RIDGE, CO 80033 PLAN CHECK # 201706354 8/21/2017 JAIMIE DAVIS 714-598-5999 12. Provide and show new and existing smoke and carbon monoxide detectors in the following locations a and b. - (No existing) New - Done Shown on A2 and A3. �p 13. Where windowsill is located higher than 72" above adjacent grade or finished surface on the opposite side, the lowest part of the opening shall be 24" minimum above the room finish floor surface. Done. Shown on SPIS page 3 of 5. 14. Enclosed attics and enclosed rafters spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space. Not applicable - SIPS roof no attic or rafters. Shown on N/A 15. Where eave or cornice vents are installed, insulation shall not block the free flow of air. Not applicable - SIPS construction. Shown on N/A A16. Roof drainage shall have a controlled method of water disposal from roofs. Done Shown on A4. Al 17. Provide bathroom exhaust fans complying with table M1507.4. Mechanical capacity of 50 cfm intermittent or 20 cfm continuous. Done. Shown on M2 - Notes #6 and drawing. 13 18. Note a minimum 4" nominal diameter exhaust fan vent for the clothes dryer. Done Shown on M1 and M2 - Notes #6 and drawings. ly 19. Provide manufactures specifications of the wall HVAC units. Done Shown on M2. IS 20. The service disconnect means shall be located in a readily accessible location outside of the building. Done Shown on M1. 21. Provide and show GFCI protection to all 120 volt, 15 and 20 amp receptacles... Done. Shown on M1 and M2. PLAN REVIEW RESPONSE LETTER 9965 W 34TH DRIVE WHEAT RIDGE, CO 80033 PLAN CHECK # 201706354 8/21/2017 JAIMIE DAVIS 714-598-5999 Ib 22. Provide and show on plans AFCI protection for all 15 and 20 amp branch circuits.. Done Shown on M1 and M2 17 23. Provide a switch and exterior light at door entrance at the deck. Exterior lights shall be a high efficacy lighting NEC 210.70(A)(2)(b). Shown on M2 drawing and General Notes #4. IS 24. Note that Exterior receptacles shall be listed as weather proof / tamper resistant. Done. Shown on M1 and M2 drawings and Electrical Notes #1 i9 25. Add note that All new receptacles shall be listed tamper resistant (NEC 406.12). Done Shown on M1 and M2 Electrical Notes #2 10 26. Show the control valves and shower heads are located on the sidewall of shower compartment. Done Shown on M2. 2I 27. All plumbing fixture flows rates shall comply with sec 403 and 408 IPC. Done Shown on M1 and M2 Plumbing Notes #1. 22 28. Specify U -factors values for all fenestrations on window and door schedules. Add note to schedules "fenestrations must have temporary and permanent labels for verification of the building inspector." Done Shown on A5 and A6 U factors labeled on windows/doors and Note added. A 29. Note on the plans not less than 75% of the lamps installed permanently installed light fixtures shall be high efficacy lamps. Done. Shown on M1 and M2 Electrical Notes #3 added. 30. The frost line in the city of wheat ridge is 36 inches below grade. Revise detail FW1/S1 to show a minimum footing depth of 36 inches from grade to top of footing. Done Already was on FW1/S1. No changes needed. PLAN REVIEW RESPONSE LETTER 9965 W 34TH DRIVE WHEAT RIDGE, CO 80033 PLAN CHECK # 201706354 8/21/2017 JAI M I E DAVIS 714-598-5999 1. Plan review approval from: Building, Planning, and Public Works Dept. 2. All plans shall be wet stamped and signed prior to permit issuance. 3. Include the following on the cover sheet: A- G - Done Shown on Cover Sheet 4. Remove Redlines - Done J� Shown on All Sheets U 5. Revise sheet A3 to show new walls as double lines. Show all doors to clarify interior circulation. Show wall separating bonus room from bath. Wall appears to bisect exterior window. - Done. window placement was corrected on A3. Shown on A3 6. Identify vertical direction of stairs. Specify total vertical height. Show handrails. - Done Shown on A3 and SIPS page 2 of 5 section A Q7. Revise sheet A4 plan label from 2nd floor to Roof Plan. - Done Shown on A4 8. Clarify if pergola is new or existing. Done Shown on cover page. /6\ 9. There are two 2/A6 cross section keys on sheet A6. Coordinate on sheets A3 and A4 �--� with A6. Done. Shown on A6. D10. Show the water closet in master bath. Demonstrate 15 inches clear from the centerline of the water closet tot he adjacent finished wall surface and minimum of 21 inches clear in front of water closet. Compartments to be a minimum of 30 inches x 60 inches in depth. - Done Shown on A3. /$\ 11. Show the location of the washer and dryer in the laundry rooms. Demonstrate the �--� exhaust ventilation as required by IMC 504. Shown on M1 and M2. PLAN REVIEW RESPONSE LETTER 9965 W 34TH DRIVE WHEAT RIDGE, CO 80033 PLAN CHECK # 201706354 8/21/2017 JAI M I E DAVIS 714-598-5999 12. Provide and show new and existing smoke and carbon monoxide detectors in the following locations a and b. - (No existing) New - Done Shown on A2 and A3. jp 13. Where windowsill is located higher than 72" above adjacent grade or finished surface on the opposite side, the lowest part of the opening shall be 24" minimum above the room finish floor surface. Done. Shown on SPIS page 3 of 5. 14. Enclosed attics and enclosed rafters spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space. Not applicable - SIPS roof no attic or rafters. Shown on N/A 15. Where eave or cornice vents are installed, insulation shall not block the free flow of air. Not applicable - SIPS construction. Shown on N/A Aii 16. Roof drainage shall have a controlled method of water disposal from roofs. Done Shown on A4. 17. Provide bathroom exhaust fans complying with table M1507.4. Mechanical capacity of ILI 50 cfm intermittent or 20 cfm continuous. Done. Shown on M2 - Notes #6 and drawing. 13 18. Note a minimum 4" nominal diameter exhaust fan vent for the clothes dryer. Done Shown on M1 and M2 - Notes #6 and drawings. I� 19. Provide manufactures specifications of the wall HVAC units. Done Shown on M2. IS 20. The service disconnect means shall be located in a readily accessible location outside of the building. Done Shown on M1. 21. Provide and show GFCI protection to all 120 volt, 15 and 20 amp receptacles... Done. Shown on M1 and M2. PLAN REVIEW RESPONSE LETTER 9965 W 34TH DRIVE WHEAT RIDGE, CO 80033 PLAN CHECK # 201706354 8/21/2017 JAIMIE DAVIS 714-598-5999 Ib 22. Provide and show on plans AFCI protection for all 15 and 20 amp branch circuits.. Done Shown on M1 and M2 �� 23. Provide a switch and exterior light at door entrance at the deck. Exterior lights shall be a high efficacy lighting NEC 210.70(A)(2)(b). Shown on M2 drawing and General Notes #4. Ig 24. Note that Exterior receptacles shall be listed as weather proof / tamper resistant. Done. Shown on M1 and M2 drawings and Electrical Notes #1 i9 25. Add note that All new receptacles shall be listed tamper resistant (NEC 406.12). Done Shown on M1 and M2 Electrical Notes #2 10 26. Show the control valves and shower heads are located on the sidewall of shower compartment. Done Shown on M2. 2I 27. All plumbing fixture flows rates shall comply with sec 403 and 408 IPC. Done Shown on M1 and M2 Plumbing Notes #1. 22 28. Specify U -factors values for all fenestrations on window and door schedules. Add note to schedules "fenestrations must have temporary and permanent labels for verification of the building inspector." Done Shown on A5 and A6 U factors labeled on windows/doors and Note added. A 29. Note on the plans not less than 75% of the lamps installed permanently installed light fixtures shall be high efficacy lamps. Done. Shown on M1 and M2 Electrical Notes #3 added. 30. The frost line in the city of wheat ridge is 36 inches below grade. Revise detail FW1/S1 to show a minimum footing depth of 36 inches from grade to top of footing. Done Already was on FW1/S1. No changes needed. CeramiCircuit' Ceiling Cove Mount Heaters High Efficiency Ceramic Infrared Panels Model 1445 - 1500 Watts Model 945 • 1000 Watts �L Radiant Model 645 . 825 Watts Electric Model 632 • 585 Watts Heat The Ultimate in Energy Efficient Heating • Silent • Reliable • Economical • Residential • Apartments & Condos • Commercial • Assisted Living • Industrial • Medical & Clean Room ® • Garage and Shop • Remodeling ® Distributed by: • a t in g 360.715.4328 www.heatinggreen.com -CeramiCircuitTM' Ceiling Cove Mount Heaters Model 1445 •1500 Watts Model 945 •1000 Watts �gr�ee Model 645 •825 Watts Model 632.585 Watts ,• ��_+„ andinstall trictried'eat c., t ,u r pian. The The room and alt 6bjeets lri it are , beater std be ' ft "d Y to. provae maximum; ofx stay uty sateirated with infrared energy, just radtarit tieatrng energy orttptt as it trey vuere le#t in the sun on a *arm � d' , Because heat seeks cold all objects Heater elements are to � constructed of ceranafc �t circuit coated f8,gauge steel onthe 3ntemat face oflates with th heati an energizing rti te=radiate and-reflect the heattn `pyo all Efiiections, meaning that comfort comes s element o� olxz eye i -direction_: Neater body shaft be ai 2i3 gauge galvanized steer' construct with, ventilation slots at perimeter and 26 gauge steel 'bezel with high t®rriperature; powder eotrfig, Placing the hed An the exterior waif creates a baftwAgainst the Heater, hWf have a,junction box of approximately 6.75" �. � �ches�#he baclCst¢e ofd haiert�ody: There shall of bodyllat to.,tlle cold-window be three:7f8" standard knockd ts.in the junction:- box to tlncler the l teateC: all6wentry-ofpouter feed. At",power connections to — ®> * _ the elermnr and heater grounding' connection shall be Cold floors areril an issue with ----: — attheteitendAftheheater. a ceramiGircuir trlstallatiom Evert Heater elements shalt ,have a wattage density of a comfort is the rUld.Vith just`a 4' floor, minimurn of 2:3mattslsquare inch ofemissiye surface to eeiBrig.temperature-difference; g area typical, although each structure vuiii itacy., in tireard_The floor is warmed: lust ,shall r mstatt rnamafacfiarer's st�splied" like ever , oilier ab ect irl the room. powder664ated mounting brackets (2) as specified on 1 thetart, and finish Withsupplied panel end trim piecesa27 . Ratings & Apprpv,ls DoNot mount lrlarn��Uil1 Heaters, shall be rated at 585 watts :(Model 634, 825 On Low Density 1i = ' watts (Model 645}, 1000 watts (Model 945)',. or 1500' Materials Such C2litrlg watts. (Model 1.445) in appropriate voltages. of 120 X`Z'` As Pegboard C1eai 3rlGe volts, -208 volts, 240 volts, or 277-volts. Heaters eaters , shale be listed and app _ toyed:. by Supplied Mounting Brackets Underwriter's Laboratories. rovide Proper 368,Art( ge .PT� For Correct Energy,fllstributloo /// Model Dimensions Watts BTUs Ship Wt. 1445-C 45'"W x 15"H x 10"D' 1500 5150 48 lbs. i 240 volt/6.2 amps 208 volt/7 2 amps 126 volt/12.5 amps 277 volt/5.4 amps 945-0 ` 46"W x 10"U" x 7.5"D 1000 3414 20 lbs. 2417volt14.2 ari�ps 2€38 volt/4.$,amps. 120 volt/8.3 amps 277 volt/3.6 amps t Minimum Etevatiotl To Bottom �# Heater 645;C 4'6"W x 7"H,x 5.5"D &25 2 1? i5 lbs. 240 volt/3.4"amps 208 volt/3.9 amps 120 volt/6.8 amps 277 volt/2.9 amps 632-C 33"W x 7"H x 5.5"D 585 1989 11 lbs, 240 volt/3-4 amps 2£38 volt/2.9 amps 120 volt/4.8 amps 277 volt/2.3 amps " .. • Infrared energy heats people, not space. Find comfort at lower air temps ;, • Low temperature operation. Typically less than , ' 350° F on the element. Distributed by: j } • Allergy free and sinus friendly. No pipes, no heatingl- I ;- .. ducts, no furnace, no chimneys, no mainte- 9pt en nance, no visible glow when in operation. www.heatinggreen.com • Ten year warranty 360.715.4328 m 2003 CeramiCircu t^' is a Registered Trademark of Radiant Electric Heat 410 r c SO a Go C. an 0 z Z Q Z oz w W0 0 (a) 0 LJ i1 O L Y � F z_ Z W W Z w `n 0 `n b 0 LOLir-I� E �Q 3 a � LO N m Z m � -� Io E o uj F- U 0 L) U N E J � ■ m!1 w LL rs, o `n `q `n b 0 LOLir-I� �Q 3 .N u Ln N LO N LO N �U ^ O Io M F- U 3 0^ m 10 N � o ■ m!1 w 0 �,o N o `n `q `n b LOLir-I� 3 LO N Ln N LO N LO N _ ^ O Io M 10 10 10 N LO° LO N°2O 3 �,o N Lo Lo LO U:*'0'oo`� OL T)cc \ 2 \ � # (D k » E (\ « \ \ \ k \ \ § { —)� 0 \ / / k \ \ 0 E 5 \ \cn k� �% S \ \\ \� cc C \ z ¥5 ca 0C °° 6 72 k b )a o }/ � 22 ) $'f %\ c E 3w 0ƒ / E{ y 2 S 0 §\ \ a 2 »2 k �\ \ -0C /a 60 o �� <° ƒ }2 / 0 ) `t / \ f% /k 3 ® — (qy D Q \ co §=g /\ c \\ § \f , E e7 o 700 0U) ®_ Eo §, —c \ 0 £ n¥ :S g / 0 $% E >�8 $ k2 F ® -C- ®., 5R . oa® ®22g }\ =Z k t E0 E =a / ,60 \ D a% &e m{ 9 \ \ ] LU = »U3 CU )\ Mk £ }\ \\ S 3 a 0. L) / G o—_ c 4°_ _$ §« , 2 a) § 2 =® c LU �� \ \/�k CD �/ a) ® ƒg 2§ E w ]ƒ . 5 E m 0 cl)G% r §§ E ` p \§ 2 °°°— 2` a' �� {� $2 CD 2 a\cE %7 $$ G 00 «m @£ o JUJ z z 2 )a) - E® E E \ c c �$ r- :3 0= °° CL en }\ \�°2 §2 {! / ¥a E Q \ 2§/° et— #� Lu o� c= o c \% e— �k 4= co �± _® U) \\ w w 2\ f W/ a E a 6 E k a& \ \ � # k » E « \cm { 0 5 \ S \ 0 a / % \ k co ) o ƒ e / 0 / D Q \ {\ 2 § f / \ \ \ / \ m % . § a \ ) k D ccE / » @ D \ \ 9 \ $ £ o = �2 S } §� £ ,m S — E k \ § J f k \ / § a r R w 4 a 2 a) C N ca E 7 a NC CL CO a o m a) a c N o m _ y U O U y m C O N O a C U CD 0) aS C y Vl @ C C � a) 0 .A 0 U m O m 06 y C O m a) m O fC .D CF h a) a) C O O L a) � m 0 a) m m T of w O Y E �O w v r m y o 3 D o m �m E 1; I n�L c m. 3 c U�m CD 4> -0d 3aaN07 0L� ® OO a) -O yO Ly c y C O D 0) y O m vo m �CC$ 0cm > @ E Lr_mE:n�) O)o m m m> V y °� 'r O_ Q N m 3 CO Y 0 m -00 .L..• m U a) a) E M C a) C m co U C w T a) a) 0 0 m LL Cc � m� ami o 3 n Yc o m ca U y a aciEami yam cmimo ^+ aim �E a� 8 -01 c CD CO E u) y co a C 0 O Q) 3 a1ca JE co U= • N U� C L U p UCy aU UCC- Z E Oc Lw0) 0 r- wE Q 0 m O 0 w O 0o 0) N C- C V OY�Cl) m UwC C a ?+_'E a CL d m N y m cc 3 V O `' y o� C m a 'O .m. > - L 70 C) r m L m ` U a) O- � m C N CO N C' A® a) C E c a m �: C L a) C 0 CL L O N N "� N a O a5 O O c .0 .m.. O m w 3 m y �.- m 0) tc6 U) N m 7 c0 ( m cU-0 C w tp d O .m. ,� p) p) C 'L" 0) a) y y m Q 0 M C E Y t (0 O 0 .Vj a1 O- O N E CD> � CD O y❑ E w a) c 0 ' y dt m m m 3N o)E c mLr CO_ m m m 3 d E c y m COT X -o C o o E aO w- m ca TO m 3�-C U c 0 m y O UO a) ECQ 3 ;m ae m Ua) y aO arc 0. m a m L C t w U a Z mc cp y.m m 0 m O 0 y O- O -Ow m L� N N m c 3 m o C 0) 0 �8 0 m 0 a c c co tC 3 `- y U 0f U C O o m 0f @ c m U m c mV m o m mw c m0 jL� c E Som cc a m E c c ami � 16 yw c m o> c y cc m �" E c 8 tLj m ) c ococm asmE ot`mo w =m m m c y w L y m co ._ O y � 0) m- U O "E m 0 6 m 0) O m s 3 m � c c r c m 3 �i mmmEa Qmc c -0x a m -,m (D Tsm F- Q 0(D w Q c o m w w .R m uo. 2.9-0 � cOi Mo S cca � �i Of vi :3 v Lci cc d r ao ai N,E E O S co LL CeramiCircuit' Ceiling Cove Mount Heaters High Efficiency Ceramic Infrared Panels Model 1445 • 1500 Watts Model 945 • 1000 Watts Radiant Model 645 • 825 Watts Electric Model 632 • 585 Watts Heat The Ultimate in Energy Efficient Heating • Silent • Reliable • Economical • 'f • mur,Tr€xDmfort at (owes# operafrng expense,' raetyro ep lrr beige or mite Mat i ,,,, Atr g bracl�afs tinct tarn panels s, • Residential • Apartments & Condos • Commercial • Assisted Living • Industrial • Medical & Clean Room • Garage and Shop • Remodeling Distributed by: aft• heftati •Aeft"a"k re '�ffc3r?,f� oresrmo 360.715.4328 www.heatinggreen.com CeramiCircuit' Ceiling Cove Mount Heaters Model 1445 -1500 Watts Model 945 •1000 Wafts Model 645 -825 Wafts Model 632.585 Wafts T 'he rbbbVand all as if jr6mevery directiob� - "th Placing thMPater on -the 0 wr ist"th wall creates,-abafrieragair loss. of body,'beat1GAbe "C.046W� undeir t 4 --------- I Cold floors aren't an issue with f aberarniCircLift Even th fi'- just floor cornfort is, 'e rule a4 to coiirigt eratur6difference�,b&lng, typical, although each structure,wiff4vary- in ihis.�rega�rd. The floor-is,war-med iust. likb-every other object ln'the room. Do Not Mount Minimum On Low Density" Materials Su& 6' Ceiling As �,e-gboard­ Clearance P,ro\ffde Proper 36 - For Correct Energy 6 Minimum Elevation" Tb 1 1 Boitom OfHeater - Distributed by: ,-A heating 1111111.0 ,-Vv` I Wk, en www.heatinggreen.com 360.715.4328 are energy "Jul", oma`warm all object flie h0afin )rnwicom Pool and Install. Ce#aWing, q Oprited h JtkW .'Pane r6a th, heater ;s3ratk be provide, ma)am , urn St radia bating�,o, ut Heater elements are to be constructed ol-ceramic coated 118 gauge- steel plates with an, energizing' circuit on, the internal faoe,of the heaftinaelement 7 . Heater, body-,shalL, .gauge. galvanized steel, constructmAW-ventilaii6n slois�,at, perimeter and 20, I gauge steak witty high temperature: '98 pe rature- powder ► -coating. t7t Heater shall have ajunction -box -appro)dely6.7S iriches'4 thebeater of -,�-Trr4h6r& shall bofhrao,7' standard Rno6lkouts in the,jo ction, box 10 Stourontryy.of, ver-feedActuaLpower connections -to the element 11 and heater grounding connection shalt be at the'le-ft end ciftheheater. , HeAter elements shalf Tuve a, -,wattage density of a , emissive surface C, shall iWalt MW lied powder ,c oatoft-.modriting bracckets (2) as specified on 111, ` the 'pian, and finish with supplied panel end trim pieces,(2): PatingsA ` Approvals Heaters shall be rated at 585 watts (KADdef 632), 825, watts,,(Model 645),,1000 watts (Model 945), or 1500 Watts (Model 1445) in -appropriate voltages of 120 vofts, 208 ypits, 240,v6lts, or .277 volts. eaters, shall be listed and> approved by Underwfiter,s Laboratories. Model Dimensions Watts BTUs Ship Wt - 1445-C 46,"W,x 15"rH x 10"D 1500 , 5150 48 lbs. 240volt:J6.2aimps 208 volt/7"_2 amps 120 volt/ 12.5 amps -277 volt/5.4 amps 945-C, 46M x 1,0"H'x 7.5"'D 1000 3414 20 lbs. 240volt/44a�nap,s 208"1JVp1t/4,8:amps,. eM volt/8.3 amps '277 volt/3:6 amps 645_12 46!/W X 7 -x 5.5"D $23 2817 15 lbs. 240 volt/3.,4 amps 208 v.q1V3.9-,,amps 120volt/63amps 277volt/2.9amps 632-C 33"W x 7!'H,)<,5.5"D 585 lbs. 246, volt/14 amps, .208 volt/2,9 amps 120,volt/4.8"ajaps 277 volt/2.3 amps' Infrared energy heats people, not space. Find comfort at lower air temps • Low temperature operation. Typically less than 3500 F on the element. • Allergy free and sinus friendly. No pipes, no ducts, no furnace, no chimneys, no mainte- nance, no visible glow when in operation. (U L) . Ten year warranty 02003CerarniOircuit- is a Registered Trademark of Radiant Electric Heat 410 ca ca 0 z z O 2 W 0U J Q D Z L Z 0 W Q.. a 9 nn o E Q m w m � E I O E 0 LL J ■ME (4 1 o Iq a Lq b 0 0 LO LO m� 3 00 0 LO N to N LO N U p V Ly - �w 10 3 0 ^ 'm, �O N X98; 00 w i _3: 3 Q o Iq Lq Lq b LO LO r -I 3 LO N LO N to N LO N J M co��� 10 10 �O N LO 00 O O 3 >'o NLO�`r' Uor»�d \ CL { \ $» % k 6 k » E / \ ] ¢k « \ \ \ / } 5 k \ \ \ § &Z 0c ` k § �® ± 2=0 m to ® ; Q 5 E cm cn c /j }R3 @% 00 \ 0 \% Sk cn ¥0 cc §2 6) & )® �° k a§\ 7% k }» C £ k E\ ° E c/°§ 5l/ g° \ C 8� t D c 31- �\\E a Rf \ � E ]g E ƒa 2 �/k $E ®� m ® �2 j\ of 7 \ay /\ 0k / \ \\ k/ k K/ )a \\ k / \/ __ & \06 *E =o k c= a 22 2 ]% E \a/ §\ ƒ\ e \ \� \§ m� S2 £ c ok® ®\®@ __ It= 2 CL =a — f »- to ? L ? \ -or w k� ) §\\-0 /k § { S 0) \§ L) a g«c" §f }� } }) W ck }k// §� }f • �. /E {§ _� t = m k c E E jƒ \ \\j/ o // \ k\ // -k / c 3- - 2 C a \} 2 L) G7 @$ :3 G \\ q£ }@ w m7 c \m=/ 0« �= I =' = 7° a a)zm °\ 0) )§ k� �/ m _ # ,8am E m ) > ° \ �� , & °° 2� E °c E \ J / § \ § ) \ 3 \ A @ \ 175 f f /E w &,o£ wg 4= a aE k= a= \ \ $» k » E « 0 ° £ § £ S \ \ / 0 \ C \ k ° )ca } \ a 0 2 j 31- a a / \ E 2 k E \ƒ 2 o § f m \ \m % / 0 k g )a \ ) k / » @ { 2 \ / \ 0m 3 e = e �- S° 57 } £ c \° cc- /3 k ? L m a & w 4 7 e N co 0E U 'gym w23 a °oc° r- !E m� c�L �U 0 p 0 0 o f m> m° m o m O w m U L `p I F- vi o � -' 0 �' � 0) ai c� a o ° o c9 S m o C6 cu co m m �= > 3 E o �, ,� 3� m G� C O m E C Ym O m (D Q 0 m L) m c y U O m o_ Q � � 0 F c mc? N a o o m E� m 3 a) > m d E N C m em cn O U C 0 m m o C Q LL m 'm o a p� 3 m� m m p 0 �' 0 a `° L ° m w O 'C om E m m C£ m CO 'O m L U y L 7 m m Y rn mo O o C C �n 3 m C 660 O "O m U ° T U w O U W C p 0 p L O U N m8L 1 Q` O O U ` m�co — O Q N m Cca O m m L m � m m' m c. a p o C E m m' O c° O m p Y C O m Cy m E m m'a m= 0 N C z O C o m 16 45 m O. C N m d Ul m C m C O E U 'L' m— m m m m C o m �_ o m V m CO m m > C° O (6 0) m 'a -0 `oLE 3 E 0 c 0 LO 0,E C mE m a) m -0-0 co vm,� m co= X�� c o C m 0= U Qin �- :O Z U O m L m 'O to ,G O m O U E m O C U m aZ� c0 o° o m'c o �°" G .. C n o E �n m $ oF- O UL C ui m v. c ocjo w- m m c c at N 0 3 o°»c U•r- c m X �o �.� ti tmn G 0 0 c m U m o N w w m m m -O m 01 ? w U C c E S m E m m G ` Uj T t6 E O m 7 6' f ID co Y C' m ai3 O QL m O o m C L> U_ cmw = m m m EC O Q m L O O fn C J m w J m m W- M 7 = w w .R m LL 2 C 'o U L C m .- N d d is m 'U C L L Y N r o U C O U U C O G c: U C oU m m o UL m cn m C O .y c0 3 � m m O mp 0 C m C W M C m m m m U L L N O ° p R _ W C U m cap @ C U U U v U m m L UCU m 0 D QU m c0 N I-: N LL E GEOTECHNICAL EVALUATION REPORT 9965 W. 34 DRIVE WHEAT RIDGE, CO PROJECT No: 0299-D 16 OCTOBER 22,2016 Geotechnical, Geostructural, Environmental, Groundwater, Pavements, and Building Assessments October 22, 2016 PROJECT NO: 0209-D16 Ms. Jamie Davies Re: Geotechnical Evaluation, Proposed Residential Addition/Construction, 9965 W. 34`h Drive, Wheat Ridge, CO At your request, we have completed the geotechnical evaluation for the referenced project in accordance with the American GeoServices, LLC (AGS) Proposal No. 026116. Results of our evaluation and design recommendations are described below. 11URUIX"81011 REM The project site is located north of W. 34`h Drive in Wheat Ridge, Colorado at location shown in Figure 1 and Figure 2. The site is developed as a residential property. Site topography is flat. The surrounding development consist primarily of residential construction. The proposed development will consist of an addition to the existing residential structure. We anticipate proposed structure will be constructed with light to moderate foundation loads. If these proposed conditions change, we should be contacted to modify our report. 2663 Cinnabar Road www.americangeoservices.com Mailing: 191 University Blvd, #375 Colorado Springs, CO 80921 sma@americangeoservices.com Denver, CO 80206 Ph: (719) 761 6072 Ph: (888) 276 4027 Ph: (303) 325 3869 Fx: (877) 471 0369 SCOPr Oi WORK On October 19, 2016 one Standard Penetration Test location B 1 shown in Figure(SPT 2• Using CME 55 e ) equivalent borehole DriveProbe(WDp equivalent (B1) was au apparatus, borehole was extended to the maximum hand-held e gored at the existing ground surface gU1Pment, and Williamson Obtained. WDp (BGS). The augers were used to adv um exploration de was used to evaluate soil consistent ante the borehole and grab ab samples feet below exploration device which is used to grab sam y or relative density. WDp is pies Fere soil and decomposeddetermine the distribution a "relative density, rock units. and to estimate strength ��� Pound hammer which free falls roughly a resistance to penetration is gth of the subsurface measure of resistance to ghly 3.5 feet Pen measured in blows_per-1/2 foot of description oesist geotechnical Penetration can be used to estimate relative dench sity an 11' g finical exploration method pipe into the ground' This 1994, P. 317-321 , please refer to Volume tY of soils. For a more detailed A representative schematic of me I, USD Penetration Test (SPT) is included in an A A, EM -7170-13 WDP and correlation data with conventional S August Log included in an A Appendix. The penetration test results are shown on Standard included in an Appendix. The Legend and Notes necessary ry to interpret nte the Borehole rpret our Borehole Log are also After the completion of materials were collected at regular boreholes were bac kfilled with soil coffin Placed in gular intervals during drilling.gs• Samples of subsurface soil a sealed container, and The sam Groundwater level transported to ples were visually inspected, to measurements were testing laboratory for logged, visual observation taken during oratory further visual evaluation. soil classification and g and after the co other soil laboratorymoisture content dete completion Of drilling. tests/evaluation were not deemed necessary. rmmation Besides on the borehole log. 'and Atterber ry. Results of laboratory g Lrrmts testing, ry tests are included Data obtained from site observations experience in the area was used v ' subsurface exploration then used to reach conclusions and reco perform engineering'laboratory evaluation analyses. Results of en and previous rmnendations presented in grneering analyses were SUBSURFACE this report. RFACE. CONDITIONS Subsurface conditions encountered in orehole Appendix. Soil classification and identficationBislbased are described in detail in the Borehole Log provided in Practice of geotechnical en i girreerin on commonly accepted methods e r represent transitions be g In some cases, the strati employed in the between soil graphic boundaries shown that subsurface conditions often vary rather than distinct litholo ical bo °n Borehole Logs The following�' both with de g boundaries. It should be reco � is a summa, of the subsurface conditions encountered betweenaterally the grazed e individual borehole locations. Surface Condition: t the site: f Within u r Aper 4-6 inches, brown color driveway stone/gravel is present. 9965 W 34tH PrOPosed Addition Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 2 of 15 Native Silt -Clay Mixtures: medium to hi Site is primaril high underlain b Plasticity extending to a Pth Y of mixtures of silts and clays s ground With stiff to hard soil consistencies. maximum de Y n(CL, CH' MH) with d about 20.5 feet below surface (BGS), Completely Weathered Siltstone/CIa available soils and geologic literature Ystone Bedrock: Based on our local opinion, the local sedimenta (USGS-National Geologic Database,knowledge and o ry bedrock is present below 12 feet extends o several to ur review of formation is known to exhibit low to 2016, Bulletin 1121-L) 34th Street high in our ' and high plasticity g plasticity throughout the region ns offeet. This bedrock ty at random locations in g that is close and the site vicinity area. adjacent to W Groundwater: Groundwater was not encountered during extended to a depth of 20.5 depths, feet BGS We do mg drilling or at the completion of P This observation May not anticipate water levels within the drilling variations in the y not be indicative of other times or at locations other g which anticipated excavation groundwater level may be experienced ' largely depend upon the duration and in the than the site. drainage intensity future. The ma Some g characteristics of the s �' °f Precipitation, tem magnitude of the variation will Founding area temperature and the surface and subsurface urface Seismicity: Based on the results of International Building°ur subsurface explorations and review of available literature this project. However this site classification m Our opinion, a site classification `D�� (2006 velocity study We do not anticipate seismically be revised b may be y Performing Y used for y induced liquefaction g a site-specific shear wave GF;O'l I potential at the site. CH �'ICAIa CONSIDERATIONS The presence of medium to high concern for the g plasticity silt-cla Proposed construction. The site is not locatedmixtures at the site swell potential., Poses a significant m an area ma geotechnical Aped as having moderate to high In order to manage the eotec should be noted that ougreco hnical risks, we provide followin Of the recommendations are intended as g foundation options with associated risk. It geotechnical data obtained during guidance. The rmg our evaluation and followinassumptions:y are based on our inte • Proposed/Final site g rpretation grades will not differ si Proposed foundationsgnificantly from the current site grades; • Structural loads are static in nature• ground; and • Proper surcharge loading, underpinn�g, and shoring requirements engineer in the structural design, Will be considered by the structural 9965W 34th Proposed Addition Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 3 of 15 Impact of the by the structural Connections between the uctural en existing Followinggtneer, g and new struct const ures will be properl the designruction recommendatio y considered of the proJect. ns are provided to own interpretationEntities requiringhighlight as Of the information aspects of construction that equipment subsurface conditions °n various aspects of co and work schedule. could affect in order to Bete construction must rrnme const make their OPT10,,�; 1: CONVF TIONAt construction methods cost, 5I1At I O`'' S RE,,%D FOO This option can be used provided the owner TISf S (Alo'')FR`1TE_ RISk) movement and related recommendations structural is willing to take the damage• In order to moderate may be used for manage risk of future construction: ge the risk to differential Foundation subgrades should be prepare some level following a Over- d as to assn excavate the subgrade b ming favorable structural Ell coin y 24 inches Feather conditions: pacted to at least 95% and backfill ns: b• An AGS S� Of With imported representative M D698 maximum granular free - placement Of should dry density. draining concrete. inspect and approve the Foundations bearin compacted structural fill allowable bearing g upon Properly prior to the Y prepared and pressure of approved sub Esti up to 2,000 pounds grade should Estimated final structural per square foot (ps be designed for ructural loads fl a maximum However, as a will dictate the minimum, we reco final fo l 8 inches ' rrrmend rrn and size of foundations m width. Isolated bearing walls be su inches square. columns should pported b to be cons be su y continuous footin constructed. supported on pads with gs of at least � Continuous foundatio mini n walls shouldmurn dimensions Of 24 Of at least 8 feet to be reinforced in the reinforce further aid in resisting top and bottom to went as shown Figureg differential 3 span an unsupported len • Exterior footingsshould movement As length and f, in be placed. a minima gs in m, additional • unheated Foundation base areas should extend ment walls should be a below design measures should beign frost de q underpinning implemented wngm Fc� designed as retaining walls an depth of 36 inches. as sho Adequate d adequate const rprnning for the quate drainage ruction. pro existing footings the foundation per surcharge loadinggs and shorin design. for existing g should be provide g footings or d for site stability during new footings should be considered in 9965 W 341h Drive, Proposed Wheat Ridge Co Project No: 0299-D16 October 22, 2016 Pte„_ We estimate total heave/movement for foundations designed and s, with differential moveconstructed as discussed in this section Will be in the range of 1.5-2.0 inches or lesents fourths of the total. mon the order of one-half to three - OPTION II: STRAIGHT -4 AFT PIER FOUNDATION (MINIMAL RISIti) This option can be used if the owner or heave and related structural dma e ots to significantly reduce the risk of g minimal. Following recommendations future differential settlements aspects of design and construction that could significantlyg mmendations are provided to highlight requiring that on various aspects of deiaffect the performance rmance of the project. Entities conditions. After the review of structural g must make their o wn and architectural project plans and interpretation of the subsurface we will Perform additional exploration or ma reco followin recommendations: P Y mmend deeper soil boreholes confirm Oosed loads ar mo g mmendations: Fading, defy • Piers should have a minimum design length of 20 feet below the bottom of foundation 1 • The minimum pier diameter (D evel. ) will depend on the len the L/D not exceed 30. gth (L) to diameter ratio (L/D)• We recommend A minimum pier diameter of 12 inches is recommended Of the pier hole durin to facilitate Proper g construction. P per cleaning and observation • Piers should be designed for an allowable end bearing capacity friction value of 1,500 P ty of 15 000 psf for the minimum 10 feet embedded portion of the s Band an allowable skin hard material. Where there will be tension loads or uplift on resisted b P into the very stiff to the Y skin friction of the pier embedded below 5 feet of the ground Piers, the tension loads should be Of 1,250 psf can be used to calculate uplift capacity. $ and level. The skin friction value • Some movement of drilled pier foundations should be anticipated to mobilize skin the required movement will be on the order of 1/8 to 1/4 inch. Differential Piers may friction. We estimate Y equal the total movement. movement between adjacent • Piers should be designed for a to concentrate the dead load n1 t� Piers. um dead � the d a5,000 psf based on the pier cross-sectional area minimum pier lengths and bedrock d load pressure cannot penetration values should be incrfo c achieved, then the minimum dead load deficiency. Application of dead load pressure is the most effective ensate way tooeS resist foundation uplift due to swelling soils. st • All axially loaded piers should have a minimum center -to -center spacing of at least three pier diameters (3D). All laterally loaded piers should have a diameters (6D) in the direction mininlum center -to -center spacin Perpendicular to pier loading. Parallel to pier loading, and 2.5 diameters g of at least six pier g Piers placed closer than (2.5D) in the direction these values should be designed using the 9965 W m R'oPosed Addition 34 Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 5 of 15 appropriate reduction factors to account for group action. For the final design, the exact geometry of the pier group should be submitted to us for review and approval so that appropri be made to our recommendations. ate modifications can • Piers should be adequately reinforced to their full length. Reinforcement should extend well into grade beams and walls. Steel to pier ratio of a minimum of 0.005 based on cross-sectional area of pier is recommended. More reinforcement may be required from structural considerations. As a minimum, one #5 rebar per 18 -inch pier diameter should be used to resist uplift tension generated by swelling soils. An approximate uplift force in kips may be calculated using the formula D*20 where `D' is pier diameter in feet. • A minimum 6 -inch continuous void space should be provided beneath foundation walls or pier caps to concentrate the dead loads of the structure on the piers. The absence of void space will result in the reduction of deal load pressure which, in turn, will result in the uplift of foundation. • The project specifications should allow for modifications b installation. y geotechnical engineer during the pier • The contractor should mobilize proper equipment so that drilling in weathered bedrock or unanticipated hard materials can be achieved to required depths. The contractor should carefully review this report to account for all possibilities and extras in their bid to avoid high cost overruns. • Considering the presence of very stiff clayey soils and no groundwater table, the use of casin and dewatering equipment is not anticipated. g • Mushrooming of the pier top should be avoided by not allowing the pier size to vary towards the surface. ground • Drilled pier holes should be cleaned of loose material prior to concrete placement. Once the proper depth is achieved, the auger should be placed in the bottom of the hole and several high-speed revolutions should be made to clean the bottom. Loose cuttings should not remain in the bottom of the excavations prior to concrete placement. • While drilling piers, excessive remolding and caking of bedrock or very stiff/hard clayey material on pier walls should not occur. All such materials should be removed to achieve design skin friction strength values. • Concrete should be onsite and ready during drilling of piers. Concrete should be placed immediatel after pier observations and measurements are made, and reinforcement is set within eholey Groundwater was not encountered during our investigation and is not anticipated to be a significant factor during construction of the piers. Pier holes should not be left "open" overnight. Proposed Addition 9965 W 34t' Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 6 of 15 • Concrete to be placed in the piers should have a slump of 5 to 7 inches. If more than 3 inches of water is present in the bottom of the pier hole, de -watering should be performed using a pump or tremie prior to concrete placement. • Installation of drilled piers should be observed by a member of American GeoServices, LLC on a full- time basis to identify and confirm that subsurface conditions are consistent with those encountered in our soil boreholes, and to monitor construction procedures. • Assuming that the pier length to diameter ratio PD) will be greater than 7, in our opinion, the Matlock and Reese method of analysis can be used for lateral load analyses. Therefore, the lateral soil -structure interaction of single shafts may be analyzed using the software application, LPILE developed by Ensoft, Inc (or equivalent such as COM624). This analysis procedure estimates the lateral load -displacement behavior based on elastic beam -column theory and soil reaction -displacement (p -y) curves. Deflection, bending moment and shear profiles at specified intervals along the length of the shaft are computed. • For lateral load analysis, modulus of horizontal subgrade reaction values of 25 tcf and 50 tcf may be used for soils/bedrock materials present in upper 10 feet and hard materials present below 10 feet, respectively. Resistance to lateral load in upper 5 feet should be neglected. These recommendations may be modified while working closely with project structural engineer/designer. • As noted earlier, all laterally loaded piers should have a minimum center -to -center spacing of at least six pier diameters (613) in the direction parallel to pier loading, and 2.5 diameters (2.5D) in the direction perpendicular to pier loading. Piers placed closer than these values should be designed using the appropriate reduction factors to account for group action. For the final design, the exact geometry of the pier group should be submitted to us for review and approval so that appropriate modifications can be made to our recommendations. Total lateral load versus deflection graph for the pier group can be developed by adding the lateral load resistance of piers at selected deflections. • For a detailed LPILE analysis, we should be contacted to provide specific input soil parameters or to review input parameters and to participate in the pile design along with project structural engineers. We estimate total heave for foundations designed and constructed as discussed in this section will be less than 1.0 inch, with differential movements on the order of one-half to three-fourths of the total. SLAB -ON -GRADE The "Slab Performance Risk" associated with native expansive soils/bedrock materials at the site is "Moderate to High" as defined and published by the Colorado Association of Geotechnical Engineers (CAGE). According to CAGE, the `slab performance risk' is an engineering judgment which is used as a predictor of the general magnitude of potential slab heave/settlement and the risk of poor slab performance. If slab areas are over -excavated down to 6 feet and backfilled with non -expansive structural fill, or if a Proposed Addition 9965 W 34" Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 7 of 15 structural slab is used in conjunction low. with OPTION II foundations, then the Slab Performance Risk is very The actual slab movements that will to predict accurately because these occur on a particular project site aremovements depend on loads, eva o-tr an subsurface drainage, consolidation characteristics, swell i very difficult, if not impossible, index, swell p essures and so 1 suction value and slab -on - actual time of year during which the on future slab -on -grade movements. grade is constructed has been found to have a lar s• The ge influence Slab heaves or settlements are normally defined in terms of "total" and " movement refers to the maximum amount of heave or settlement that the slab differential" movement. " "Differential" movement refers to Total" experience, sometimes over relatively short horizontal distances eave or settlement that different may experience as a whole. determined to be one-half of the total movement in soils points of the same slab may es. Differential movements are arbitrarily differential movements can occur ' exhibiting Low Slab Performance Risk. Greater natural soils abruptly transition to fill material.here expansive soils have been encountered and where the For design of floor slabs, a modulus of subgrade reaction of 200ound ci) may be used Provided slab -on -grade is placed on Properlyp s Per cubic inch Procedures described earlier. prepared subgrades after the completion of�soil modification We recommend that the construction measures outlined in the following paragraphs be followed to reduce Potential damage to floor slabs, should wetting of the subsurface soils occur: • Separate floor slab from all bearing vertical movement. Under any circmstancanwalls � columns with expansion joints floor slab should to allow unrestrained over foundation grade beams without saw cutting the slab at the beam after c not extend beneath exterior doors or • Provide slipconstruction. joints around exterior walls, interior non-bearing at least 3 inches of free vertical movement of the slabs as illustrated in, and interior columns t Figure 3. If wood or metal stud allow Partition walls are used, they should be designed and constructed to allow for movement at the bottom of the walls. • The connections between the interior, slab-su should allow for differential movement. For s ab bearin Ported partitions and exterior foundation supported walls Notwithstandingblock partitions, provide sli g' if the floor moves, the P joints structural distress such as cracking, partition walls may still show signs of • If partition walls, masonry block walls, or any other walls without bottom best to support them oneams slip the slab independent of a�foundations. hick are, in turn Joints are required, it is supported on piers. In other words, construct 9965 W 34tH Proposed Addition Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 8 of 15 • If options are not available and slab -bearing structural distress may be reduced by connecting he parts walls are necess �'Y, then the potential for • Frequent control joints should be provided at about 10afttion walls to exterior walls using slip channels. eet with shrinkage and cracking according to ACI specifications. Control ' spacing in the floor slab to reduce problems thickness, aggregate size, slum Joint spacing is a joint spacing, P and curing conditions. The requirements for concrete slabtion of th ckness g, and reinforcement should be established by the designer, based on experience, design guidelines and the intended slab use. Placement and cu ng co ' on the final concrete slab integrity P Hence, recognized gI ty. Floor slabs should be adequately will ll have a strong impact • The need for a vapor barrier will depend on the sensitive sensitive floor coverings are proposed for portions of the sensitivity f floor coverings to moisture. If moisture typically consisting p Proposed structure, a capillary g of a "clean" gravel, should be considered. p �' break material, recommendations if this is the case. We can provide additional • Provided gravel is desired below the slab, a layer of 4 to 6 inches can be used. through slabs should be isolated from the slabs and provided with movement. Plumbing passing A positive bond break should be Provided where 1 flexible connections to allow for Under slab, plumbing should be avoided if p Plumbing lines enter through the slab. Possible. possible and should be brought above the slab as soon as • Where mechanical equipment and HVAC e of a flexible connection between the qutpment are supported on slabs, we recommend provision movement. mace and ductwork with a minimum of 2.5 inches of vertical • Sidewalks and other exterior flahvork should be separated from the sla as an independent unit, band the slab should be designed STRUCTURAL FLOOR OR CRAWL SPACE If a structural floor or crawl space is used for this project, the grade be physically isolated from the underlying void or crawl space of minimum of 8 hes or what expansive e materials with beamscrawl-space lsand floor system should type construction. The requirement is. ever minimum current Uniform Building Code (UBC) For crawl -space construction, various items should be considered in t beyond the scope of geotechnical scope of work for this project and require the design and construction that are 6 these include design considerations associated with clearance, ventd specialized expertise. Some of Practice, and local building codes. Ifnot ro erl p p y drained and constructed, there lislthe Potential for section to develop e, crater nt us, through transpiration of the moisture/groundw moisture the structure, water in ater within native soils underlying trusion from snowmelt and precipitation, through irrigation of lawns and landscaping.and surface runoff or infiltration of water In crawl space, excessive moisture or sustained elevated 9965 W m PrOPosed Addition 34 Drive, Wheat Ridge, CO Project No: 0299-' October 22, 2016 Page No: 9 of 15 f i humidity can increase the Potential for mold to Professional engineer in building systems should addresslo P °n organic building materials. A qualified moisture and humidity issues. RETAINING WALLS Foundation walls and basement walls (if used) should be designed to be rigid for on-site fill materials. If needed, only g (unyielding), and not free to fined to resist an equivalent fluid density backfill should be used. Retainin y imported granular backfill meetin of 55 pcf to resist an equivalentg Falls for unrestrained conditions (free lateral moven nt Class 1 structural fluid density of 45 backfill or CDOT pcf for on-site fill materials and 35imported ) an be designed Class 1 structural backfill. Forpassive for im orted passive resistance of 300 psf per foot of wall height.sive resistance o f P granular for contact between the prepared soil surface and concrete unrestrained walls, we recommend A coefficient of friction value of 0.35 may be used e base. The above recommended values do not include a factor ofsafe adjacent foundations, slog ty or allowances for surcharge loads such as values do not include hydrostats pressures as the vehicle traffic, or hydrostatic Pressure. to provide additional reco Y are based on drained condiThe above reco tions. nunended mmendations for any specific site retaining conditions. We should be contacted Retaining wall backfill should be placed in strict accordance with our beover-compacted earthwork recommendations given As a precautionary measure, a drainage collection system excessive lateral pressures on the walls. in the wall design in order to minimize h Gains or geosynthetic drains) should be included board such as the hydrostatic pressures. A prefabricated drainage composite or drain side of the basemen foundation 000 or an engineer -approved all.equivalent may be installed along the backfilled SUBSURFACE DRAINAGE Groundwater was not encountered during or after the com letio subsurface drainage is critical for lon term _ p n of drilling. Nevertheless recommendations illustrated in Figure g Performance of the proposed s Proper foundation option chosen. glue 4 and given below should be strictly fol owed, depending minimum, upon the • A Perimeter drain/dewaterin g system should be installed to reduce the Potential for groundwater entering into foundation and slab areas. The 10t -specific eter Properly designed and connected to the suitable discharge from the lot. dewaterin g systems should be • The subgrade beneath a structural floor system should be nd. in addition, drain laterals that span the crawl pace are recommended graded so that water does not the crawlspace. mmended to prevent ponding of water within 9965 W ,n Proposed Addition 34 Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 10 of 15 • As a minimum, the subsurface drainage system should consist perforated rigid PVC pipe surrounded b typically of 4 -inch minimum diameter should be wrapped in a geosynthetic Pipe should to prevent fine soilsone PiPfroiiiciio er of free draining gravel. The pipe drain by gravity to a suitable all-weather outlet or to a ging the system in the future. The system. If an outlet or area underdrain isnot available, the subsurface Properly designed area underdrain to sump pits with sum standby P Pumps havingnage system should be sloped y capacity in the drainage event of pump failure. ' Surface cleanouts of the perimeter drain should be installed at minim the addition. A properly constructed drain system can result in a ream serviceability the subsurface soils. Drains which are im improperly distances arouof nd P perly installed can introduce ase settlement r ture heave tion e subsurface soils and could result in are surface grading only cave of the • The entire designY compounding the potential issues. and construction team should evaluate, within their respective field o current and potential sources of design construction criteria to alleviatefwat r throughout the life of the f expertise, the structure and provide any systems are used, the actual desi Potential for moisture char construction means and methods should bet, outlets, trved by a ocation should be designed recommended drain by AGS. The Y representative of AGS. SURFACE DRAINAGE Proper surface drainage should be Operations. maintained at the site during and after completion of construction Based on the intended use of the proposed facili local, state, and federal regulatory agencies should be strictl f Mowed drainage recommendations provided illustrated in Figure 4 and given below should be implemented. mendations As a minimum, recom • It is important to follow these reco elements throughout the life of the facili endations to minimize wetting or tY• Construction means and drying Of the foundation metho which minimize improper increases/decreases in the moisture contents ds should also be utilized • The ground surface adjacent to buildings should be sloped to Promote of soils during construction. We recommend a minimum slope of six inches in the first five horizon to ra id areas. These slopes should be maintained during P run-off of surface water. P tal feet for landscaped or g the service life of buildings, graveled • Landscaping should be limited aro Plants with low mid building areas to either xeri-sca in moisture requirements. Irrigation should be minimal and limited to m Roof do p P g, landscaping gravel, or wns outs should discharge on splash -blocks or other impervious from the building. ai11 in plants. g Ponding of water should not be allowed i Pervious surfaces and directed away ' Upper 2 feet of exterior grading or landscapingfill laced i immediately adjacent to the building. I Oft) should be relatively impervious P immediately adjacent to the buildin to minimize water infiltration adjacent to the building. g (within use plastic membrane in lieu of impervious fill to cover the � g Do not ground surface. 9965 W 34m P'oPosed Addition Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 11 of 15 • Again, positive drainage away from the new structures is essential to the successful performance of foundations and flatwork, and should be provided during the life of the structure. Paved areas within 10 feet of structures should slope at a minimum of 2 percent away from foundations, and landscape areas within 10 feet of structures should slope away at a minimum of 8 percent. • Downspouts from all roof drains, if any, should cross all backfilled areas such that they discharge all water away from the backfill zones and structures. Drainage should be created such that water is diverted away from building sites and away from backfill areas of adjacent buildings. EARTHWORK At the time of report preparation, grading plans were not available. If cuts and fills exceed basement level depths, we should be contacted for specific earthwork recommendations, especially stability of adjacent structures, shoring requirements, cut slopes, and construction dewatering. In any case, site grading should be carefully planned so that positive drainage away from all structures is achieved. Following earthwork recommendations should be followed for all aspects of the project. Excavation: Materials encountered at this site may be excavated with conventional mechanical excavating equipment. Although our boreholes did not encounter "buried" foundation elements or other structures or debris, these materials may be encountered during excavation activities. Debris materials such as brick, wood, concrete, and abandoned utility lines, if encountered, should be removed from structural areas when encountered in excavations and either wasted from the site or placed in landscaped areas. Temporary excavations should comply with OSHA and other applicable federal, state, and local safety regulations. in our opinion, OSHA Type A soils will be encountered at this site during excavation. Based on our review of OSHA guidelines, we recommend maximum allowable unbraced temporary excavation slopes of 1:1(H: V) for Type A soils for excavations up to 10 feet deep. Permanent cut slopes are anticipated to be stable at slope ratios as steep as 2H:1 V (horizontal to vertical) under dry conditions. New slopes should be revegetated as soon as possible after completion to minimize erosion. These recommendations can be modified once site grading plans are made available. We recommend a minimum of 10 feet of clearance between the top of excavation slopes and soil stockpiles or heavy equipment or adjacent structures (subject to approval of AGS). If braced excavations are to be used, they should be reviewed and designed by AGS. It should be noted that near -surface soils encountered at the site will be susceptible to some sloughing and excavations should be periodically monitored by AGS's representative. Proposed 9965 W 34th Drive,W�t at Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 12 of 15 If excavation is performed under water table, or excavation is made steeper than Proper shoring should be provided. It is contOSHA recommendations, ractor's responsibility to assure safe earthwork operations. safety during excavation and Construction Dewatering: Due to the absence of high water table, construction dewatering critical for this project. As a minimum, an interceptor drain outside the entire Perimeter will not be building may be considered with proper maintenance during construction. Sumps er of proposed required. and pumps may also be We recommend scheduling excavation activities to minimize excavation below water to caving and subgrade disturbance does not occur. Notwithstandin for excavating ble so the soil (if at all required), we recommend lowering the water table by at least 2 feet below the ottowater of table level level, and using granular materials for removal and replacement of disturbed clays. m of excavation During construction in wet or cold weather, from the building areas. Promptly 'grade the site such that surface water can drain readily away excavations or on subgrade surfaces pump dpaout r rtherwise e areas to remove any water that may accumulate in ng ditches and similar means may be used to prevent storm water dry bentering theefore lwo k construction. Berms, any water off-site efficiently. a and to convey Fill Placement: Excavated on-site materials may be reused in the non -foundation areas sas slabs, pavements, and landscape areas, provided they are free from organics uch and any non -soil materials Fill material should be placed under proper moisture control, in uniform horizontal layers (lifts) not exceeding 8 inches, before compacting to the required density and before successive layers are contractor's equipment is not capable of properly moisture conditioning and compacting 8 -pinch placed. then If the the lift thickness shall be reduced until satisfactory results are achieved. Highly plastic cla siltstone/claystone bedrock should not be re -used on-site except in landscaped areas. ys or weathered On-site recycled fill to be placed should be moisture treated to within -1% to +3% of o ti content (OMC) and compacted to 95% of Standard Proctor (ASTM D698) maximum p mum moisture Compaction in landscape areas should be tan or dry density or greater. greater. Fill under the foundations should be non -expansive and free from organics and non -soil materials. structural fill should consist of sand or als. Imported in addition, this material shall have a liquid limit less than 30 and a plaal with a sticity particle size of 3 inches or less. In fill should also have a percent fine between 15 to 30 percent passing the No. 200 sieve.x of 15 or less. Structural should be moisture conditioned to within 2 percent of OMC and compacted to at least 95 Percent of fill Proctor (ASTM D698) maximum dry density. Compaction in the wall backfill areashould of Standard greater. be 85% or 9965 W 34th Drive,Proosed Wh t Ridge,1t i. aCO Project No: 0299-D16 October 22, 2016 Page No: 13 of 15 Permanent fill slopes are anticipated to be stable at slope ratios as steep as 2H:1 V (horizontal to vertical) under dry conditions. New slopes should be re -vegetated as soon as possible after completion to minimize erosion. Cold Weather Construction: If earthwork is performed during the winter months when freezing is a factor, no grading fill, structural fill or other fill should be placed on frosted or frozen ground, nor should frozen material be placed as fill. Frozen ground should be allowed to thaw or be completely removed prior to placement of fill. A good practice is to cover the compacted fill with a "blanket' of loose fill to help prevent the compacted fill from freezing overnight. The "blanket' of loose fill should be removed the next morning prior to resuming fill placement. During cold weather, foundations, concrete slabs -on -grade, or other concrete elements should not be constructed on frozen soil. Frozen soil should be completely removed from beneath the concrete elements, or thawed, scarified and re -compacted. The amount of time passing between excavation or subgrade preparation and placing concrete should be minimized during freezing conditions to prevent the prepared soils from freezing. Blankets, soil cover or heating as required may be utilized to prevent the subgrade from freezing. CONCRETE & STEEL CONSTRUCTION Concrete sidewalks and any other exterior concrete flatwork around the proposed structure may experience some differential movement and cracking. While it is not likely that the exterior flatworks can be economically protected from distress, we recommend following techniques to reduce the potential long- term movement: • Scarify and re -compact at least 12 inches of subgrade material located immediately beneath structures. • Avoid landscape irrigation and moisture holding plants adjacent to structures. • Thicken or structurally reinforce the structures. We recommend Class 2 sulfate resistance as per ACI 201 standards for all concrete in contact with the soil on this site. Calcium chloride should not be added. Concrete should not be placed on frost or frozen soil. Concrete must be protected from low temperatures and properly cured. We anticipate corrosive potential for on-site soils. A qualified corrosion professional should evaluate site conditions and provide proper recommendations for buried metal structures. LIMITATIONS Recommendations contained in this report are based on our field observations and subsurface explorations, limited laboratory evaluation, and our present knowledge of the proposed construction. It is possible that soil conditions could vary between or beyond the points explored. If soil conditions are encountered during Proposed Addition 9965 W 34'h Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 14 of 15 construction that differ from those described herein, we should be notified so that we can review and make any supplemental recommendations necessary. If the scope of the proposed construction, including the proposed loads or structural locations, changes from that described in this report, our recommendations should also be reviewed and revised by AGS. Our scope of work for this project did not include condition survey of existing structures or structural evaluation or design of any kind. Our scope of work did not include research, testing, or assessment relative to past or present contamination of the site by any source. If such contamination were present, it is very likely that the exploration and testing conducted for this report would not reveal its existence. If the Owner is concerned about the potential for such contamination, additional studies should be undertaken. We are available to discuss the scope of such studies with you. No tests were performed to detect the existence of mold or other environmental hazards as it was beyond Scope of Work. Local regulations regarding land or facility use, on and off-site conditions, or other factors may change over time, and additional work may be required with the passage of time. Based on the intended use of the report within one year from the date of report preparation, AGS may recommend additional work and report updates. Non-compliance with any of these requirements by the client or anyone else will release AGS from any liability resulting from the use of this report by any unauthorized party. Client agrees to defend, indemnify, and hold harmless AGS from any claim or liability associated with such unauthorized use or non-compliance. In this report, we have presented judgments based partly on our understanding of the proposed construction and partly on the data we have obtained. This report meets professional standards expected for reports of this type in this area. Our company is not responsible for the conclusions, opinions or recommendations made by others based on the data we have presented. Refer to American Society of Foundation Engineers (ASFE) general conditions included in an appendix. This report has been prepared exclusively for the client, its' engineers and subcontractors for the purpose of design and construction of the proposed structure. No other engineer, consultant, or contractor shall be entitled to rely on information, conclusions or recommendations presented in this document without the prior written approval of AGS. We appreciate the opportunity to be of service to you on this project. If we can provide additional assistance or observation and testing services during design and construction phases, please call us at 1 888 276 4027. Sincerely, Sam Adetti` Senior Engi Proposed Addition 9965 W 341h Drive, Wheat Ridge, CO Project No: 0299-D 16 October 22, 2016 Page No: 15 of 15 Mfftlll=- I, t e�. m 0 cQ m a O U �a as rn 00 a 0� co o O a� b Cc r' C12 t0 0 d . .. iy s V+y :i N ,L 7 ^# i u O i0 w r U �p P1 C\2 0 ai O O Fri - O U a H .v W �d 0U H Ent- O d � � � � o F ch w ti 0 b O O P4 cd Q4 a Ic ,m a a o a0 ° a `� c to O V2 o .. °1 Cao o G. CQ W a to aW U al A mo W W W A �� W 40 h� [� O W O zn ` r 0� ao W 0 CQ P, toq 93 Uy (d °a> `� �d D� aoc0b �^ C) � '0 V 'b N OO U L V W ++ a) U y.,°,� U q o U o p+.�+U+ J .� �, W 5i G �•ODO U O r. OD U ° ® O V b Fri OD LCDs U r p O 40 N Q o zE- F�-1 j1' lad o .'. oz 0 04) o 0 a :o Z O C o' D � rn U A di 431 'b(�' �N 0 U 10 = M O O 0+��, °x V a)d d Fa zlk *k r3 O V a .r c w u �� x :+ d z O a) CO +� N G" (D ' � cl y x"41 ��� 00 93 —. U� w i.+ a 0 O —00 R. a) 4 1 ti F+ 45 y q 'v.. R. ad U U c0 k Q. C\2 mc°> Q) M a' a 'ao H W Q b o � �� a� p a b ti •o .. e O (z CD tu ° o za 03 03�m p o a> Cd tea. � a00d api 0-54. eo pa•.. CD a°oe ��b o ^d b adq �0o Cd MO° AyPO (D Cd ro 0 4> �cdd O O d' N w cv4 ao 0•� a aa+' Icu a 0 E• O O q O m U 0 0 Nb10 a q�. m� I \ 'm rA� O y p ti v c. �„a• � 04 p ;O O oo,oOcuo 41 cb �0 0 d \ \ 1:4 0 p a ~ . Iz ��0 m � \o ep m0��ON 0,� c7 M. 01 � O � .� UU 0 tl 0 t o�� wo IV d " mp cJ W ;0.. q r- 0 N m � m O I G' E12 a 0 " ✓ p a ops a d U O maw roao OF m z °Z7 < X00 X w x A�w m co w A'� w I o 0ad b 04 p 0 a co -� o qI & m p '7 "' b C .0 0.0 m U O 00 00 0 b U U V W ad a � O O � U •+ O y m x. U a ad a p'��°' "a > ani 0 m 41 too di m to °a U ti a 40 "" l a o ao w�04000 O c0 a ,� 6Z oFo oR0 ;w,, O z .-i U U + CV b e� .� •`d O D p 10. �m C\2 .0 0,0 .� Q 0 a1 I� ° J � � m� I \ 'm rA� O y p ti v c. �„a• � 04 p ;O O oo,oOcuo 41 cb �0 0 d \ \ 1:4 0 p a ~ . Iz ��0 m � \o ep m0��ON 0,� c7 M. 01 � O � .� UU 0 tl 0 t o�� wo IV d " mp cJ W ;0.. q r- 0 N m � m O I G' z a a OAE w WOA 04A az a0A V.. E12 a 0 " ✓ p a ops a d U O maw roao OF m z °Z7 < X00 X w x A�w z a a OAE w WOA 04A az a0A V.. LO Id a U b ° o o 0 4j 14co q w maw 0 w OF A� z °Z7 < X w x '0 Fri � :d P. m co w a o w I o 0ad b 04 p 0 a co Q b ° o o 0 4j 14co q H en45 '0 Fri � :d P. m co Ac�0 a o w I o 0ad b 04 p 0 a co U aC a qI & m p '7 "' b C .0 0.0 m U •M •m 4 00 00 0 b U U V ad a IV cd 0 � U •+ O y m x. U a a, a a a ani 0 m °°Z '�'0 a'04 di m to °a 10 a s a o ao w�04000 O c0 maw P. o �d ;w,, O z .-i U U + CV b e� .� •`d A m Z 'o Z ui LABORATORY DATA SUBSURFACE EXPLORATION DATA B1 9965 W. 34th Drive, Wheat Ridge CLIENT: Davies Project Number 0299-D16 Drill Rig: CME 55 Eq. and Williamson Drive Probe (WDP) Geologist/Engineer SMA Ground Elevation Not measured Date Drilled 10-12-2016 Total Depth of Borehole 20.5 Feet Borehole Diameter 4 Inches Depth to Water Not encountered � o Description / Lithology A 3 a O a a un 0 Brown crushed rock, existing driveway_ SANDY CLAY to SILTY CLAY, brown, '4 stiff to very stiff, moist, medium to high plasticity f 11 16 1.6% 30 38,18 at 5 500 psf CH 32 37 39,25 1 41 .f''. SILTY CLAY to CLAYEY SILT, olive gray to gray, very stiff to hard, moist, high plasticity (Possibly completely weathered MH siltstone/claystone bedrock) SILTY CLAY, olive gray, hard, moist, 15 X high plasticity (Possibly completely '" weathered claystone bedrock) 40 51,32 c 0 51 ... z 68 _ 20 -Exploration terminated at 20.5 ft due to high - WDP blowcounts. Groundwater seepage was not encountered during or at the completion of exploration. AMERICAN GEC E VICE$, LLC 1 () 276 4027 Page I OOC O O e F o A CO a 0 ZT Cl F 0 a o ,b 14) a %) XaGm A.LIaLLSvrld F: a Q d U U OOC O O e F o A CO a 0 ZT Cl F 0 a o ,b 14) a %) XaGm A.LIaLLSvrld F: a Q Descriptive Tenninology & Soil Classification PW 1 Oil TYPICAL DESCRIPTIONS DESCRIPTIONS 41-101 WIN I ..«' ; �, ILII ly ���� � �,! �. mom IIIA I.,tM -y&qj . PW 1 Oil TYPICAL DESCRIPTIONS ........... IIIA PW 1 Oil Descriptive Terminology & Soil Classification taboratory/Field Toting Definitions for Fxploralion Logs DD = Dry Density (Pcf) WD-WotDenft*f) Mc -Moisture content Plastic Unit (*A) LL - Liquid Limit (%) P1= Plasticity Index OC = organic Correct (%) S - Saturation Patent SG - Specific Gravity C - Cohesion m= Angle oflniemal friction qu - Unconfined Compressive Strength #200 =Percent PUMS the Number 200 Sieve CBR - California Besting Ratio VS = Vane Shear PP = Pocket Penctrurnoter DP Drive Probe SPT = Standard Penetration Test BPF - Blows Per Foot (N val=) SH - Shelby Tube Sample GW - Groundwater RQD - Rock Quality Desideatim TP = Test Pit B - Boring KA - Hand Auga V - Groundwater Level/Seepap Encountered During Exploration = Static Cmindwater Level with Date Measured SPT lExploradons - Standard perietration Wring is perPenned by dnvmg a 2 -inch O.D.spit"poon sampler ido the undisturbed formation at the bottom of the boning with repeated blows ofs 140 -pound pin -guided hammer h1fing: 30 inches. Number ofblows IN value) required to drive the sampler a given distance was considered a measure of soil consistency. SH Sampling- Shelby tube sampling is peri'mmed with a thin waited sampler pushed into the undistrubcd soil to ample 2.0 fed ofsoil. Air Track Exploration - Testing is performed by measuring rate of advancement, and samples am retrieved from cuttings. Hand Auger Exploration - Testing is performed uscing a 3.23' diameter auger to advance into the earth and amieve saarpim 60 so X 0 ,640 k3o ,M 20 a. 10 0 casistatley ofCobcsive sells ConSioxtiq SPT (OPF) PP (tat) very Soft 0-1 los than 0.25 Soft 2-4 025-0.5 Me&= Stiff 5-9 0.5-1.0 Stiff 9-15 1.0-2.0 very stiff 16-30 2.0-4.0 Hard 30+ ova 4,0 Relative Density OfCohnionless Soils Very Loom 0-4 t4oft 5-10 MO&UMD003C 11.30 Dense 31-50 Very Dense W Particle size Identification Name Diameter (inchm) Sieve NO. Rock Block >120 Boulder 12-120 Cobble 3-12 Gravel com-be 314-3 Fine 114-3/4 No. 4 saw Course 4.7S mm No. 10 Mcdium. 2.0 mm No, 40 Fiat 0,425 mot No. 200 Silt 0.075 mm, Clay <0.005mm Drive Probe Explorad— - This "relative density" exploration device is used to determine the distribution and catimate strength ofdw subsurface soil and doO004med M& units. The resistance to penetration is measured in blows -par -1 12 foot of an I I -pound hammer which froo falls Mug* 3,5 Eftt driving the S inch diameter pipe into the ground. A schematic of the drive probe apparatus is included in the subsurlhoc explonstion portion *f the appendix. For a more detailed description of 1his geotechnical exploration method, the Slope SOUNV Reference Guiciefor Wadowl Forests in &0 UM1W states, VOAMO 1, Unused Sk*j Dquironew ofAgricufture, FM -71 70-13, August 1994, p. 917-321. CPT Exploration - Ounz Penetrometer Explorations consist ofituabing a probe couinto tare ow* using the mammofa2G-tontruck. The cone resistance (qc) and stem friction resistance (Is) am measured as the probe was pushed into the earth, The vahms ofqc and fs (in tit) are noted as the localized index of soil strength - 0 10 20 30 40 50 60 70 80 90 100 Liquid Lim It (%) i Drive Prove I Schematic Pate i• - 4 :, ---A f Center Dri Weld Plate 7/8 in. Hole Herei 12 b& Drop Rand Stock Hammer 7 in. Weld Plate Chamfer Lj Here 3/16 in. 4 f t. -112 v2 n I*1 plate 3� Chamfer V16 in. i Plate 4 in.a. 1/2 in. Galvanized Center Drill Water pipe 7/8 w. Hole $ ft. 112 in t }enchant i i Co ® 1l2 in. PSse 4 ft. i DriveP ole i a, Drib 3116 ai: Hole 90 deq. Apart 2 in. q t Reference: Figure 3.6.1, Appendix 3.6, Page No. 321, USDA EM -7170-13, August 1994, Volume I i 30 25 20 10 of 5 Ii CORRELATION WILLIAMSON DRIVE PROBE (WDP) STANDARD PENETRATION TEST (SPT) Dorado (n =10; y = 0:6482xu" R2 = 0:68133 Lower Eel In = 50) Y= 0.845x(k1474. R2 - 0.5761 Freshwater (n = 86j R2 = 0:5824 SOURCE: Published literature by W.C. Adams (Hart Crowser, Inc.), R.W. Prellwitz (Bitterroot Geotechnical) & T.E. Koler (El Dorado National Forest). C sl 38 .. �.. rt -a=20 rt lr+.� 4� ♦ a 15Y ♦ ►1 r 'A A" i • ' to at 'rrt _e. _. .: ; ._.. ...... +; {1 10 20 30 40 so 60 Williamson Drive Probe D (bpi) emV Doak PI i �s " Padfle Lumber Co. — F od SOURCE: United States Forest Service, Technology Development Program Website (http: //www. fs . fed. us/t-d/programs/iin/wi lliamson_drive/c orrelation. shtml) Elk River (t3 = ) _ R2 =0.3027 x ; 4 I i :X Fl Dorado • 7RiM • Freshwater A Elk 20 SIU 60 � —• 'w Elk River - - - lower Eel W0P (blows/ft) i Fresta ater Et Dorado SOURCE: Published literature by W.C. Adams (Hart Crowser, Inc.), R.W. Prellwitz (Bitterroot Geotechnical) & T.E. Koler (El Dorado National Forest). C sl 38 .. �.. rt -a=20 rt lr+.� 4� ♦ a 15Y ♦ ►1 r 'A A" i • ' to at 'rrt _e. _. .: ; ._.. ...... +; {1 10 20 30 40 so 60 Williamson Drive Probe D (bpi) emV Doak PI i �s " Padfle Lumber Co. — F od SOURCE: United States Forest Service, Technology Development Program Website (http: //www. fs . fed. us/t-d/programs/iin/wi lliamson_drive/c orrelation. shtml) As the client of a consulting geotechnical engineer, you should know that site subsurface conditions cause more construction problems than any other factor. ASFE/the Association of Engineering Firms Practicing in the Geosciences offers the following suggestions and observations to help you manage your risks. A GEOTECHNICAL ENG.NEERING REPORT IS BASED ON A UNIQUE SET OF PROJECT - SPECIFIC FACTORS Your geotechnical engineering report is based on a subsurface exploration plan designed to consider a unique set of project -specific factors. These factors typically include: the general nature of the structure involved, its size, and configuration; the location of the structure on the site; other improvements, such as access roads, parking lots, and underground utilities; and the additional risk created by scope -of -service limitations imposed by the client. To help avoid costly problems, ask your geotechnical engineer to evaluate how factors that change subsequent to the date of the report may affect the report's recommendations. Unless your geotechnical engineer indicates otherwise, do not use your geotechnical engineering report: MOST GEOTECHNICAL FINDINGS ARE PROFESSIONAL JUDGMENTS Site exploration identifies actual subsurface conditions only at those points where samples are taken. The data were extrapolated by your geotechnical engineer who then applied judgment to render an opinion about overall subsurface conditions. The actual interface between materials may be far more gradual or abrupt than your report indicates, Actual conditions in areas not sampled may differ from those predicted in your report. While nothing can be done to prevent such situations. you and your geotechnical engineer can work together to help minimize their impact. Retaining your geotechnical engineer to observe construction can be particularly beneficial in this respect. • when the nature of the proposed structure is changed. for example, if an office building will be erected instead of a parking garage, or a refrigerated warehouse will be built instead of an unrefrigerated one; • when the size, elevation. or configuration of the proposed structure is altered; • when the location or orientation of the proposed structure is modified; • when there is a change of ownership; or .for application to an adjacent site. Geotechnical engineers cannot accept responsibility for problems that may occur if they are not consulted after factors considered in their report's development have changed. A REPORT'S RECOMMENDATIONS CAN ONLY BE PRELIMINARY The construction recommendations included in your geotechnical engineer's report are preliminary, because they must be based on the assumption that conditions revealed through selective exploratory sampling are indicative of actual conditions throughout a site. Because actual subsurface conditions can be discerned only during earthwork, you should retain your geo- technical engineer to observe actual conditions and to finalize recommendations. Only the geotechnical engineer who prepared the report is fully familiar with the background information needed to determine whether or not the report's recommendations are valid and whether or not the contractor is abiding by applicable recommendations. The geotechnical engineer who developed your report cannot assume responsibility or liability for the adequacy of the report's recommendations if another party is retained to observe construction. SUBSURFACE CONDITIONS CAN CHANGE A geotechnical engineering report is based on condi- tions that existed at the time of subsurface exploration. Do not base construction decisions on a geotechnical engineering report whose adequacy may have been affected by time. Speak with your geotechnical consult- ant to learn if additional tests are advisable before construction starts. Note, too, that additional tests may be required when subsurface conditions are affected by construction operations at or adjacent to the site, or by natural events such as floods, earthquakes, or ground water fluctuations. Keep your geotechnical consultant apprised of any such events. GEOTECHNICAL SERVICES ARE PERFORMED FOR SPECIFIC PURPOSES AND PERSONS Consulting geotechnical engineers prepare reports to meet the specific needs of specific individuals. A report prepared for a civil engineer may not be adequate for a construction contractor or even another civil engineer. Unless indicated otherwise, your geotechnical engineer prepared your report expressly for you and expressly for purposes you indicated. No one other than you should apply this report for its intended purpose without first conferring with the geotechnical engineer. No party should apply this report for any purpose other than that originally contemplated without first conferring with the geotechnical engineer. GEOENVIRONMENTAL CONCERNS ARE NOT AT ISSUE Your geotechnical engineering report is not likely to relate any findings, conclusions, or recommendations about the potential for hazardous materials existing at the site. The equipment, techniques, and personnel used to perform a geoenvironmental exploration differ substantially from those applied in geotechnical engineering. Contamination can create major risks. If you have no information about the potential for your site being contaminated. you are advised to speak with your geotechnical consultant for information relating to geoenvironmental issues. A GEOTECHNICAL ENGINEERING REPORT IS SUBJECT TO MISINTERPRETATION Costly problems can occur when other design profes- sionals develop their plans based on misinterpretations of a geotechnical engineering report. To help avoid misinterpretations, retain your geotechnical engineer to work with other project design professionals who are affected by the geotechnical report. Have your geotechnical engineer explain report implications to design professionals affected by them. and then review those design professionals' plans and specifications to see how they have incorporated geotechnical factors. Although certain other design professionals may be fam- iliar with geotechnical concerns, none knows 'as much about them as a competent geotechnical engineer. BORING LOGS SHOULD NOT BE SEPARATED FROM THE REPORT Geotechnical engineers develop final boring logs based upon their interpretation of the field logs (assembled by site personnel) and laboratory evaluation of field samples. Geotechnical engineers customarily include only final boring logs in their reports. Final boring logs should not under any circumstances be redrawn for inclusion in architectural or other design drawings. because drafters may commit errors or omissions in the transfer process. Although photographic reproduction eliminates this problem, it does nothing to minimize the possibility of contractors misinterpreting the logs during bid preparation. When this occurs. delays. disputes. and unanticipated costs ara the all -too - frequent result. To minimize the likelihood of boring log misinterpretation, give contractors ready access to the complete geotechnical engineering report prepared or authorized for their use. (If access is provided only to the report prepared for you, you should advise contractors of the report's limitations. assuming that a contractor was not one of the specific persons for whom the report was prepared and that developing construction cost estimates was not one of the specific purposes for which it was prepared. In other words. while a contractor may gain important knowledge from a report prepared for another party, the contractor would be well-advised to discuss the report with your geotechnical engineer and to perform the additional or alternative work that the contractor believes may be needed to obtain the data specifically appropriate for construction cost estimating purposes.) Some clients believe that it is unwise or unnecessary to give contractors access to their geo- technical engineering reports because they hold the mistaken impression that simply disclaiming responsibility for the accuracy of subsurface information always insulates them from attendant liability. Providing the best available information to contractors helps prevent costly construction problems. It also helps reduce the adversarial attitudes that can aggravate problems to disproportionate scale. READ RESPONSIBILITY CLAUSES CLOSELY Because geotechnical engineering is based extensively on judgment and opinion, it is far less exact than other design disciplines. This situation has resulted in wholly unwarranted claims being lodged against geotechnical engineers. To help prevent this problem, geotechnical engineers have developed a number of clauses for use in their contracts, reports, and other documents. Responsibility clauses are not exculpatory clauses designed to transfer geotechnical engineers' liabilities to other parties. Instead, they are definitive clauses that identify where geotechnical engineers' responsibilities begin and end. Their use helps all parties involved recognize their individual responsibilities and take appropriate action. Some of these definitive clauses are likely to appear in your geotechnical engineering report. Read them closely. Your geotechnical engineer will be pleased to give full and frank answers to any questions. RELY ON THE GEOTECHNICAL ENGINEER FOR ADDITIONAL ASSISTANCE Most ASFE-member consulting geotechnical engineering firms are familiar with a variety of techniques and approaches that can be used to help reduce risks for all parties to a construction project, from design through construction. Speak with your geotechnical engineer not only about geotechnical issues, but others as well, to learn about approaches that may be of genuine benefit. You may also wish to obtain certain ASFE publications. Contact a member of ASFE of ASFE for a complimentary directory of ASFE publications. ASFE 8811 Colesville Road/Suite G106/Silver Spring, MD 20910 Telephone: 301/565-2733 Facsimile: 301/589-2017 SUBSURFACE EXPLORATIONS SOIL TESTING EARTHWORK MONITORING GEOTECHNOLOGY FOUNDATION ENGINEERING GEOLOGICAL ENGINEERING ROCK MECHANICS EARTHQUAKE ENGINEERING GEOPHYSICS RETAINING WALL DESIGN GEOSTRUCTURAL DESIGN PAVEMENT DESIGN DRAINAGE EVALUATIONS GROUNDWATER STUDIES ENVIRONMENTAL ASSESSMENTS BUILDING ASSESSMENTS m GEOTECHNICAL EVALUATION REPORT ff 4rb Ptt '. n F 9965 W. 34 DRIVE WHEAT RIDGE, CO D F, 5� x PROJECT No* 0299-D 16 = ti - OCTOBER 22. 2016 m D F, e" idl#5. Geotechnical, Geostructural, Environmental, Groundwater, Pavements, and Building Assessments October 22, 2016 PROJECT NO: 0299-D16 Ms. Jamie Davies Re: Geotechnical Evaluation, Proposed Residential Addition/Construction, 9965 W. 34`" Drive, Wheat Ridge, CO At your request, we have completed the geotechnical evaluation for the referenced project in accordance with the American GeoServices, LLC (AGS) Proposal No. 026116. Results of our evaluation and design recommendations are described below. PROJECT INFORMATION The project site is located north of W. 34`h Drive in Wheat Ridge, Colorado at location shown in Figure 1 and Figure 2. The site is developed as a residential property. Site topography is flat. The surrounding development consist primarily of residential construction. The proposed development will consist of an addition to the existing residential structure. We anticipate proposed structure will be constructed with light to moderate foundation loads. If these proposed conditions change, we should be contacted to modify our report. 2663 Cinnabar Road www.americangeoservices.com Mailing: 191 University Blvd, #375 Colorado Springs, CO 80921 sma@americangeoservices.com Denver, CO 80206 Ph: (719) 761 6072 Ph: (888) 276 4027 Ph: (303) 325 3869 Fx: (877) 471 0369 SCOPE OF WORK On October 19, 2016, one Standard Penetration Test (SPT) equivalent borehole (131) was augured at location B 1 shown in Figure 2. Using CME 55 equivalent drill rig, hand-held equipment, and Williamson Drive Probe (WDP) apparatus, borehole was extended to the maximum exploration depth of 20.5 feet below the existing ground surface (BGS). The augers were used to advance the borehole and grab samples were obtained. WDP was used to evaluate soil consistency or relative density. WDP is a "relative density" exploration device which is used to determine the distribution and to estimate strength of the subsurface soil and decomposed rock units. The resistance to penetration is measured in blows -per -1/2 foot of an 1I - pound hammer which free falls roughly 3.5 feet driving the %2 inch diameter pipe into the ground. This measure of resistance to penetration can be used to estimate relative density of soils. For a more detailed description of this geotechnical exploration method, please refer to Volume I, USDA, EM -7170-13, August 1994, p. 317-321. A representative schematic of WDP and correlation data with conventional Standard Penetration Test (SPT) is included in an Appendix. The penetration test results are shown on the Borehole Log included in an Appendix. The Legend and Notes necessary to interpret our Borehole Log are also included in an Appendix. After the completion of drilling, boreholes were backfilled with soil cuttings. Samples of subsurface soil materials were collected at regular intervals during drilling. The samples were visually inspected, logged, placed in a sealed container, and transported to testing laboratory for further visual evaluation. Groundwater level measurements were taken during drilling and after the completion of drilling. Besides visual observation, soil classification and moisture content determination, and Atterberg Limits testing, other soil laboratory tests/evaluation were not deemed necessary. Results of laboratory tests are included on the borehole log. Data obtained from site observations, subsurface exploration, laboratory evaluation, and previous experience in the area was used to perform engineering analyses. Results of engineering analyses were then used to reach conclusions and recommendations presented in this report. SUBSURFACE CONDITIONS Subsurface conditions encountered in borehole B1 are described in detail in the Borehole Log provided in Appendix. Soil classification and identification is based on commonly accepted methods employed in the practice of geotechnical engineering. In some cases, the stratigraphic boundaries shown on Borehole Logs represent transitions between soil types rather than distinct lithological boundaries. It should be recognized that subsurface conditions often vary both with depth and laterally between individual borehole locations. The following is a summary of the subsurface conditions encountered at the site: Surface Condition: Within upper 4-6 inches, brown color driveway stone/gravel is present. Proposed Addition 9965 W 34'x' Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 2 of 15 Native Silt -Clay Mixtures: Site is primarily underlain by mixtures of silts and clays (CL, CH, MH) with medium to high plasticity extending to a maximum depth of about 20.5 feet below ground surface (BGS), with stiff to hard soil consistencies. Completely Weathered Siltstone/Claystone Bedrock: Based on our local knowledge and our review of available soils and geologic literature (USGS-National Geologic Database, 2016, Bulletin 1121-L), in our opinion, the local sedimentary bedrock is present below 12 feet extends to several tens of feet. This bedrock formation is known to exhibit low to high plasticity throughout the region that is close and adjacent to W. 34'h Street, and high plasticity at random locations in the site vicinity area. Groundwater: Groundwater was not encountered during drilling or at the completion of drilling which extended to a depth of 20.5 feet BGS. We do not anticipate water levels within the anticipated excavation depths. This observation may not be indicative of other times or at locations other than the site. Some variations in the groundwater level may be experienced in the future. The magnitude of the variation will largely depend upon the duration and intensity of precipitation, temperature and the surface and subsurface drainage characteristics of the surrounding area. Seismicity: Based on the results of our subsurface explorations and review of available literature (2006 International Building Code, Table No. 1613.5.2), in our opinion, a site classification "D" may be used for this project. However, this site classification may be revised by performing a site-specific shear wave velocity study. We do not anticipate seismically induced liquefaction potential at the site. GEOTECHNICAL CONSIDERATIONS The presence of medium to high plasticity silt -clay mixtures at the site, poses a significant geotechnical concern for the proposed construction. The site is not located in an area mapped as having moderate to high swell potential. In order to manage the geotechnical risks, we provide following foundation options with associated risk. It should be noted that our recommendations are intended as guidance. They are based on our interpretation of the geotechnical data obtained during our evaluation and following assumptions: • Proposed/Final site grades will not differ significantly from the current site grades; • Proposed foundations will be constructed on level ground; and • Structural loads are static in nature. • Proper surcharge loading, underpinning, and shoring requirements will be considered by the structural engineer in the structural design. Proposed Addition 9965 W 34' Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 3 of 15 City of ` Meat iLdige COMMUNITY DEVELOPMENT Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owner(s): \ { P, I M (-e. Nn" ; 5 Project Property: 99&S W .Lj t)r�t ve Wh2a+ f ��ctc� X00 33 signature of Applicant State of Colorado } County of e } ss The foregoing instrument was acknowledged by me this 17. day of sf 20� by ,16%M%e Layi5 JAYMESUE MCRIMMON NOTARY PUBLIC STATE OF COLORADO NOTARY iD # 20154009457 MY COMMISSION EXPIRES MARCH 06, 2019 My Commission Expires 3_/_ & 120Lq N a ublic • Impact of the connections between the existing and new structures will be properly considered by the structural engineer. Following construction recommendations are provided to highlight aspects of construction that could affect the design of the project. Entities requiring information on various aspects of construction must make their own interpretation of the subsurface conditions in order to determine construction methods, cost, equipment, and work schedule. OPTION I: CONVENTIONAL, SHALLOW SPREAD FOOTINGS (MODERATE RISK) This option can be used provided the owner is willing to take the moderate risk of future differential movement and related structural damage. In order to manage the risk to some level, following recommendations may be used for construction: • Foundation subgrades should be prepared as follows assuming favorable weather conditions: a. Over -excavate the subgrade by 24 inches and backfill with imported granular free -draining structural fill compacted to at least 95% of ASTM D698 maximum dry density. b. An AGS representative should inspect and approve the compacted structural fill prior to the placement of concrete. • Foundations bearing upon properly prepared and approved subgrade should be designed for a maximum allowable bearing pressure of up to 2,000 pounds per square foot (psf). • Estimated final structural loads will dictate the final form and size of foundations to be constructed. However, as a minimum, we recommend bearing walls be supported by continuous footings of at least 18 inches in width. Isolated columns should be supported on pads with minimum dimensions of 24 inches square. • Continuous foundation walls should be reinforced in the top and bottom to span an unsupported length of at least 8 feet to further aid in resisting differential movement. As a minimum, additional reinforcement as shown in Figure 3 should be placed. • Exterior footings and footings in unheated areas should extend below design frost depth of 36 inches. • Foundation/basement walls should be adequately designed as retaining walls and adequate drainage measures should be implemented as shown in Figure 4 • Adequate underpinning for the existing footings and shoring should be provided for site stability during construction. Proper surcharge loading for existing footings or new footings should be considered in the foundation design. Proposed Addition 9965 W 341h Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 4 of 15 We estimate total heave/movement for foundations designed and constructed as discussed in this section will be in the range of 1.5-2.0 inches or less, with differential movements on the order of one-half to three- fourths of the total. OPTION II: STRAIGHT -SHAFT PIER FOUNDATION (MINIMAL RISK) This option can be used if the owner wants to significantly reduce the risk of future differential settlements or heave and related structural damage to minimal. Following recommendations are provided to highlight aspects of design and construction that could significantly affect the performance of the project. Entities requiring information on various aspects of design must make their own interpretation of the subsurface conditions. After the review of structural and architectural project plans and proposed loads and grading, we will perform additional exploration or may recommend deeper soil boreholes to confirm or to modify following recommendations: • Piers should have a minimum design length of 20 feet below the bottom of foundation level. • The minimum pier diameter (D) will depend on the length (L) to diameter ratio (L/D). We recommend the L/D not exceed 30. • A minimum pier diameter of 12 inches is recommended to facilitate proper cleaning and observation of the pier hole during construction. • Piers should be designed for an allowable end bearing capacity of 15,000 psf and an allowable skin friction value of 1,500 psf for the minimum 10 feet embedded portion of the pier into the very stiff to hard material. Where there will be tension loads or uplift on the piers, the tension loads should be resisted by skin friction of the pier embedded below 5 feet of the ground level. The skin friction value of 1,250 psf can be used to calculate uplift capacity. • Some movement of drilled pier foundations should be anticipated to mobilize skin friction. We estimate the required movement will be on the order of 1/8 to 1/4 inch. Differential movement between adjacent piers may equal the total movement. • Piers should be designed for a minimum dead load of 5,000 psf based on the pier cross-sectional area to concentrate the dead load on the piers. If the dead load pressure cannot be achieved, then the minimum pier lengths and bedrock penetration values should be increased to compensate for the minimum dead load deficiency. Application of dead load pressure is the most effective way to resist foundation uplift due to swelling soils. • All axially loaded piers should have a minimum center -to -center spacing of at least three pier diameters (3D). All laterally loaded piers should have a minimum center -to -center spacing of at least six pier diameters (613) in the direction parallel to pier loading, and 2.5 diameters (2.5D) in the direction perpendicular to pier loading. Piers placed closer than these values should be designed using the Proposed Addition 9965 W 3411 Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 5 of 15 appropriate reduction factors to account for group action. For the final design, the exact geometry of the pier group should be submitted to us for review and approval so that appropriate modifications can be made to our recommendations. • Piers should be adequately reinforced to their full length. Reinforcement should extend well into grade beams and walls. Steel to pier ratio of a minimum of 0.005 based on cross-sectional area of pier is recommended. More reinforcement may be required from structural considerations. As a minimum, one #5 rebar per 18 -inch pier diameter should be used to resist uplift tension generated by swelling soils. An approximate uplift force in kips may be calculated using the formula D*20 where `D' is pier diameter in feet. • A minimum 6 -inch continuous void space should be provided beneath foundation walls or pier caps to concentrate the dead loads of the structure on the piers. The absence of void space will result in the reduction of deal load pressure which, in turn, will result in the uplift of foundation. • The project specifications should allow for modifications by geotechnical engineer during the pier installation. • The contractor should mobilize proper equipment so that drilling in weathered bedrock or unanticipated hard materials can be achieved to required depths. The contractor should carefully review this report to account for all possibilities and extras in their bid to avoid high cost overruns. • Considering the presence of very stiff clayey soils and no groundwater table, the use of casing and dewatering equipment is not anticipated. • Mushrooming of the pier top should be avoided by not allowing the pier size to vary towards the ground surface. • Drilled pier holes should be cleaned of loose material prior to concrete placement. Once the proper depth is achieved, the auger should be placed in the bottom of the hole and several high-speed revolutions should be made to clean the bottom. Loose cuttings should not remain in the bottom of the excavations prior to concrete placement. • While drilling piers, excessive remolding and caking of bedrock or very stiff/hard clayey material on pier walls should not occur. All such materials should be removed to achieve design skin friction strength values. • Concrete should be onsite and ready during drilling of piers. Concrete should be placed immediately after pier observations and measurements are made, and reinforcement is set within the hole. Groundwater was not encountered during our investigation and is not anticipated to be a significant factor during construction of the piers. Pier holes should not be left "open" overnight. Proposed Addition 9965 W 341h Drive, Wheat Ridge, CO Project No: 0299-D 16 October 22, 2016 Page No: 6 of 15 • Concrete to be placed in the piers should have a slump of 5 to 7 inches. If more than 3 inches of water is present in the bottom of the pier hole, de -watering should be performed using a pump or tremie prior to concrete placement. • Installation of drilled piers should be observed by a member of American GeoServices, LLC on a full- time basis to identify and confirm that subsurface conditions are consistent with those encountered in our soil boreholes, and to monitor construction procedures. • Assuming that the pier length to diameter ratio (L/D) will be greater than 7, in our opinion, the Matlock and Reese method of analysis can be used for lateral load analyses. Therefore, the lateral soil -structure interaction of single shafts may be analyzed using the software application, LPILE developed by Ensoft, Inc (or equivalent such as COM624). This analysis procedure estimates the lateral load -displacement behavior based on elastic beam -column theory and soil reaction -displacement (p -y) curves. Deflection, bending moment and shear profiles at specified intervals along the length of the shaft are computed. • For lateral load analysis, modulus of horizontal subgrade reaction values of 25 tcf and 50 tcf may be used for soilsibedrock materials present in upper 10 feet and hard materials present below 10 feet, respectively. Resistance to lateral load in upper 5 feet should be neglected. These recommendations may be modified while working closely with project structural engineer/designer. • As noted earlier, all laterally loaded piers should have a minimum center -to -center spacing of at least six pier diameters (613) in the direction parallel to pier loading, and 2.5 diameters (2.5D) in the direction perpendicular to pier loading. Piers placed closer than these values should be designed using the appropriate reduction factors to account for group action. For the final design, the exact geometry of the pier group should be submitted to us for review and approval so that appropriate modifications can be made to our recommendations. Total lateral load versus deflection graph for the pier group can be developed by adding the lateral load resistance of piers at selected deflections. • For a detailed LPILE analysis, we should be contacted to provide specific input soil parameters or to review input parameters and to participate in the pile design along with project structural engineers. We estimate total heave for foundations designed and constructed as discussed in this section will be less than 1.0 inch, with differential movements on the order of one-half to three-fourths of the total. SLAB -ON -GRADE The "Slab Performance Risk" associated with native expansive soils/bedrock materials at the site is "Moderate to High" as defined and published by the Colorado Association of Geotechnical Engineers (CAGE). According to CAGE, the `slab performance risk' is an engineering judgment which is used as a predictor of the general magnitude of potential slab heave/settlement and the risk of poor slab performance. If slab areas are over -excavated down. to 6 feet and backfilled with non -expansive structural fill, or if a Proposed Addition 9965 W 34'x' Drive, Wheat Ridge, CO Project No: 0299-D 16 October 22, 2016 Page No: 7 of 15 structural slab is used in conjunction with OPTION II foundations, then the Slab Performance Risk is very low. The actual slab movements that will occur on a particular project site are very difficult, if not impossible, to predict accurately because these movements depend on loads, evapo-transpiration cycles, surface and subsurface drainage, consolidation characteristics, swell index, swell pressures and soil suction values. The actual time of year during which the slab -on -grade is constructed has been found to have a large influence on future slab -on -grade movements. Slab heaves or settlements are normally defined in terms of "total' and "differential' movement. "Total' movement refers to the maximum amount of heave or settlement that the slab may experience as a whole. "Differential" movement refers to unequal heave or settlement that different points of the same slab may experience, sometimes over relatively short horizontal distances. Differential movements are arbitrarily determined to be one-half of the total movement in soils exhibiting Low Slab Performance Risk. Greater differential movements can occur in areas where expansive soils have been encountered and where the natural soils abruptly transition to fill material. For design of floor slabs, a modulus of subgrade reaction of 200 pounds per cubic inch (pci) may be used provided slab -on -grade is placed on properly prepared subgrades after the completion of soil modification procedures described earlier. We recommend that the construction measures outlined in the following paragraphs be followed to reduce potential damage to floor slabs, should wetting of the subsurface soils occur: • Separate floor slab from all bearing walls and columns with expansion joints to allow unrestrained vertical movement. Under any circumstances, floor slab should not extend beneath exterior doors or over foundation grade beams without saw cutting the slab at the beam after construction. • Provide slip joints around exterior walls, interior non-bearing partitions, and interior columns to allow at least 3 inches of free vertical movement of the slabs as illustrated in Figure 3. If wood or metal stud partition walls are used, they should be designed and constructed to allow for movement at the bottom of the walls. • The connections between the interior, slab -supported partitions and exterior foundation supported walls should allow for differential movement. For slab -bearing masonry block partitions, provide slip joints at the top of the walls. Notwithstanding, if the floor moves, the partition walls may still show signs of structural distress such as cracking. • If partition walls, masonry block walls, or any other walls without bottom slip joints are required, it is best to support them on grade beams which are, in turn, supported on piers. In other words, construct the slab independent of all foundations. Proposed Addition 9965 W 34" Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 8 of 15 • If options are not available and slab -bearing partition walls are necessary, then the potential for structural distress may be reduced by connecting the partition walls to exterior walls using slip channels. • Frequent control joints should be provided at about 10 feet spacing in the floor slab to reduce problems with shrinkage and cracking according to ACI specifications. Control joint spacing is a function of slab thickness, aggregate size, slump and curing conditions. The requirements for concrete slab thickness, joint spacing, and reinforcement should be established by the designer, based on experience, recognized design guidelines and the intended slab use. Placement and curing conditions will have a strong impact on the final concrete slab integrity. Floor slabs should be adequately reinforced. • The need for a vapor barrier will depend on the sensitivity of floor coverings to moisture. If moisture sensitive floor coverings are proposed for portions of the proposed structure, a capillary break material, typically consisting of a "clean" gravel, should be considered. We can provide additional recommendations if this is the case. • Provided gravel is desired below the slab, a layer of 4 to 6 inches can be used. Plumbing passing through slabs should be isolated from the slabs and provided with flexible connections to allow for movement. A positive bond break should be provided where plumbing lines enter through the slab. Under slab, plumbing should be avoided if possible and should be brought above the slab as soon as possible. • Where mechanical equipment and HVAC equipment are supported on slabs, we recommend provision of a flexible connection between the furnace and ductwork with a minimum of 2.5 inches of vertical movement. • Sidewalks and other exterior flatwork should be separated from the slab and the slab should be designed as an independent unit. STRUCTURAL FLOOR OR CRAWL SPACE If a structural floor or crawl space is used for this project, the grade beams (if used) and floor system should be physically isolated from the underlying expansive materials with crawl -space type construction. The void or crawl space of minimum of 8 inches or whatever minimum current Uniform Building Code (UBC) requirement is. For crawl -space construction, various items should be considered in the design and construction that are beyond the scope of geotechnical scope of work for this project and require specialized expertise. Some of these include design considerations associated with clearance, ventilation, insulation, standard construction practice, and local building codes. If not properly drained and constructed, there is the potential for moisture to develop in crawl -spaces through transpiration of the moisture/groundwater within native soils underlying the structure, water intrusion from snowmelt and precipitation, and surface runoff or infiltration of water through irrigation of lawns and landscaping. In crawl space, excessive moisture or sustained elevated Proposed Addition 9965 W 341 Drive, Wheat Ridge, CO Project No: 0299-D 16 October 22, 2016 Page No: 9 of 15 humidity can increase the potential for mold to develop on organic building materials. A qualified professional engineer in building systems should address moisture and humidity issues. RETAINING WALLS Foundation walls and basement walls (if used) should be designed to be rigid (unyielding), and not free to rotate. Retaining walls for at -rest conditions can be designed to resist an equivalent fluid density of 55 pcf for on-site fill materials. If needed, only imported granular backfill meeting CDOT Class 1 structural backfill should be used. Retaining walls for unrestrained conditions (free lateral movement) can be designed to resist an equivalent fluid density of 45 pcf for on-site fill materials and 35 pcf for imported granular backfill or CDOT Class 1 structural backfill. For passive resistance of unrestrained walls, we recommend passive resistance of 300 psf per foot of wall height. A coefficient of friction value of 0.35 may be used for contact between the prepared soil surface and concrete base. The above recommended values do not include a factor of safety or allowances for surcharge loads such as adjacent foundations, sloping backfill, vehicle traffic, or hydrostatic pressure. The above recommended values do not include hydrostatic pressures as they are based on drained conditions. We should be contacted to provide additional recommendations for any specific site retaining conditions. Retaining wall backfill should be placed in strict accordance with our earthwork recommendations given below. Backfill should not be over -compacted in order to minimize excessive lateral pressures on the walls. As a precautionary measure, a drainage collection system (drains or geosynthetic drains) should be included in the wall design in order to minimize hydrostatic pressures. A prefabricated drainage composite or drain board such as the MiraDrain 2000 or an engineer -approved equivalent may be installed along the backfilled side of the basement foundation wall. SUBSURFACE DRAINAGE Groundwater was not encountered during or after the completion of drilling. Nevertheless, proper subsurface drainage is critical for long-term performance of the proposed structures. As a minimum, recommendations illustrated in Figure 4 and given below should be strictly followed, depending upon the foundation option chosen. • A perimeter drain/dewatering system should be installed to reduce the potential for groundwater entering into foundation and slab areas. The lot -specific perimeter dewatering systems should be properly designed and connected to the suitable discharge from the lot. • The subgrade beneath a structural floor system should be graded so that water does not pond. In addition, drain laterals that span the crawl space are recommended to prevent ponding of water within the crawlspace. Proposed Addition 9965 W 341 Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 10 of 15 • As a minimum, the subsurface drainage system should consist typically of 4 -inch minimum diameter perforated rigid PVC pipe surrounded by at least one pipe diameter of free draining gravel. The pipe should be wrapped in a geosynthetic to prevent fine soils from clogging the system in the future. The pipe should drain by gravity to a suitable all-weather outlet or to a properly designed area underdrain system. If an outlet or area underdrain is not available, the subsurface drainage system should be sloped to sump pits with sump pumps having standby capacity in the event of pump failure. • Surface cleanouts of the perimeter drain should be installed at minimum serviceability distances around the addition. A properly constructed drain system can result in a reduction of moisture infiltration of the subsurface soils. Drains which are improperly installed can introduce settlement or heave of the subsurface soils and could result in improper surface grading only compounding the potential issues. • The entire design and construction team should evaluate, within their respective field of expertise, the current and potential sources of water throughout the life of the structure and provide any design/construction criteria to alleviate the potential for moisture changes. If recommended drain systems are used, the actual design/layout, outlets, and location should be designed by AGS. The construction means and methods should be observed by a representative of AGS. S['RFACE DRAINAGE Proper surface drainage should be maintained at the site during and after completion of construction operations. Based on the intended use of the proposed facility, all drainage recommendations provided local, state, and federal regulatory agencies should be strictly followed. As a minimum, recommendations illustrated in Figure 4 and given below should be implemented. • It is important to follow these recommendations to minimize wetting or drying of the foundation elements throughout the life of the facility. Construction means and methods should also be utilized which minimize improper increases/decreases in the moisture contents of the soils during construction. • The ground surface adjacent to buildings should be sloped to promote rapid run-off of surface water. We recommend a minimum slope of six inches in the first five horizontal feet for landscaped or graveled areas. These slopes should be maintained during the service life of buildings. • Landscaping should be limited around building areas to either xeri-scaping, landscaping gravel, or plants with low moisture requirements. Irrigation should be minimal and limited to maintain plants. Roof downspouts should discharge on splash -blocks or other impervious surfaces and directed away from the building. Ponding of water should not be allowed immediately adjacent to the building. • Upper 2 feet of exterior grading or landscaping fill placed immediately adjacent to the building (within loft) should be relatively impervious to minimize water infiltration adjacent to the building. Do not use plastic membrane in lieu of impervious fill to cover the ground surface. Proposed Addition 9965 W 34' Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 11 of 15 • Again, positive drainage away from the new structures is essential to the successful performance of foundations and flatwork, and should be provided during the life of the structure. Paved areas within 10 feet of structures should slope at a minimum of 2 percent away from foundations, and landscape areas within 10 feet of structures should slope away at a minimum of 8 percent. • Downspouts from all roof drains, if any, should cross all backfilled areas such that they discharge all water away from the backfill zones and structures. Drainage should be created such that water is diverted away from building sites and away from backfill areas of adjacent buildings. EARTHWORK At the time of report preparation, grading plans were not available. If cuts and fills exceed basement level depths, we should be contacted for specific earthwork recommendations, especially stability of adjacent structures, shoring requirements, cut slopes, and construction dewatering. In any case, site grading should be carefully planned so that positive drainage away from all structures is achieved. Following earthwork recommendations should be followed for all aspects of the project. Excavation: Materials encountered at this site may be excavated with conventional mechanical excavating equipment. Although our boreholes did not encounter "buried" foundation elements or other structures or debris, these materials may be encountered during excavation activities. Debris materials such as brick, wood, concrete, and abandoned utility lines, if encountered, should be removed from structural areas when encountered in excavations and either wasted from the site or placed in landscaped areas. Temporary excavations should comply with OSHA and other applicable federal, state, and local safety regulations. In our opinion, OSHA Type A soils will be encountered at this site during excavation. Based on our review of OSHA guidelines, we recommend maximum allowable unbraced temporary excavation slopes of 1:l(H:V) for Type A soils for excavations up to 10 feet deep. Permanent cut slopes are anticipated to be stable at slope ratios as steep as 2H:1 V (horizontal to vertical) under dry conditions. New slopes should be revegetated as soon as possible after completion to minimize erosion. These recommendations can be modified once site grading plans are made available. We recommend a minimum of 10 feet of clearance between the top of excavation slopes and soil stockpiles or heavy equipment or adjacent structures (subject to approval of AGS). If braced excavations are to be used, they should be reviewed and designed by AGS. It should be noted that near -surface soils encountered at the site will be susceptible to some sloughing and excavations should be periodically monitored by AGS's representative. Proposed Addition 9965 W 341 Drive, Wheat Ridge, CO Project No: 0299-D16 October 22, 2016 Page No: 12 of 15 If excavation is performed under water table, or excavation is made steeper than OSHA recommendations, proper shoring should be provided. It is contractor's responsibility to assure safety during excavation and earthwork operations. Construction Dewatering: Due to the absence of high water table, construction dewatering will not be critical for this project. As a minimum, an interceptor drain outside the entire perimeter of proposed building may be considered with proper maintenance during construction. Sumps and pumps may also be required. We recommend scheduling excavation activities to minimize excavation below water table so the soil caving and subgrade disturbance does not occur. Notwithstanding, for excavating under water table level (if at all required), we recommend lowering the water table by at least 2 feet below the bottom of excavation level, and using granular materials for removal and replacement of disturbed clays. During construction in wet or cold weather, grade the site such that surface water can drain readily away from the building areas. Promptly pump out or otherwise remove any water that may accumulate in excavations or on subgrade surfaces, and allow these areas to dry before resuming construction. Berms, ditches and similar means may be used to prevent storm water from entering the work area and to convey any water off-site efficiently. Fill Placement: Excavated on-site materials may be reused in the non -foundation areas such as slabs, pavements, and landscape areas, provided they are free from organics and any non -soil materials. Fill material should be placed under proper moisture control, in uniform horizontal layers (lifts) not exceeding 8 inches, before compacting to the required density and before successive layers are placed. If the contractor's equipment is not capable of properly moisture conditioning and compacting 8 -inch lifts, then the lift thickness shall be reduced until satisfactory results are achieved. Highly plastic clays or weathered siltstone/claystone bedrock should not be re -used on-site except in landscaped areas. On-site recycled fill to be placed should be moisture treated to within -1% to +3% of optimum moisture content (OMC) and compacted to 95% of Standard Proctor (ASTM D698) maximum dry density or greater. Compaction in landscape areas should be 85% or greater. Fill under the foundations should be non -expansive and free from organics and non -soil materials. Imported structural fill should consist of sand or gravel material with a maximum particle size of 3 inches or less. In addition, this material shall have a liquid limit less than 30 and a plasticity index of 15 or less. Structural fill should also have a percent fine between 15 to 30 percent passing the No. 200 sieve. Structural fill should be moisture conditioned to within 2 percent of OMC and compacted to at least 95 percent of Standard Proctor (ASTM D698) maximum dry density. Compaction in the wall backfill areas should be 85% or greater. Proposed Addition 9965 W 34" Drive, Wheat Ridge, CO Project No: 0299-D 16 October 22, 2016 Page No: 13 of 15 Permanent fill slopes are anticipated to be stable at slope ratios as steep as 2H:1 V (horizontal to vertical) under dry conditions. New slopes should be re -vegetated as soon as possible after completion to minimize erosion. Cold Weather Construction: If earthwork is performed during the winter months when freezing is a factor, no grading fill, structural fill or other fill should be placed on frosted or frozen ground, nor should frozen material be placed as fill. Frozen ground should be allowed to thaw or be completely removed prior to placement of fill. A good practice is to cover the compacted fill with a "blanket" of loose fill to help prevent the compacted fill from freezing overnight. The "blanket" of loose fill should be removed the next morning prior to resuming fill placement. During cold weather, foundations, concrete slabs -on -grade, or other concrete elements should not be constructed on frozen soil. Frozen soil should be completely removed from beneath the concrete elements, or thawed, scarified and re -compacted. The amount of time passing between excavation or subgrade preparation and placing concrete should be minimized during freezing conditions to prevent the prepared soils from freezing. Blankets, soil cover or heating as required may be utilized to prevent the subgrade from freezing. CONCRETE. & STEEL CONSTRUCTION Concrete sidewalks and any other exterior concrete flatwork around the proposed structure may experience some differential movement and cracking. While it is not likely that the exterior flatworks can be economically protected from distress, we recommend following techniques to reduce the potential long- term movement: • Scarify and re -compact at least 12 inches of subgrade material located immediately beneath structures. • Avoid landscape irrigation and moisture holding plants adjacent to structures. • Thicken or structurally reinforce the structures. We recommend Class 2 sulfate resistance as per ACI 201 standards for all concrete in contact with the soil on this site. Calcium chloride should not be added. Concrete should not be placed on frost or frozen soil. Concrete must be protected from low temperatures and properly cured. We anticipate corrosive potential for on-site soils. A qualified corrosion professional should evaluate site conditions and provide proper recommendations for buried metal structures. LIMITATIONS Recommendations contained in this report are based on our field observations and subsurface explorations, limited laboratory evaluation, and our present knowledge of the proposed construction. It is possible that soil conditions could vary between or beyond the points explored. If soil conditions are encountered during Proposed Addition 9965 W 34th Drive, Wheat Ridge, CO Project No: 0299-D 16 October 22, 2016 Page No: 14 of 15 construction that differ from those described herein, we should be notified so that we can review and make any supplemental recommendations necessary. If the scope of the proposed construction, including the proposed loads or structural locations, changes from that described in this report, our recommendations should also be reviewed and revised by AGS. Our scope of work for this project did not include condition survey of existing structures or structural evaluation or design of any kind. Our scope of work did not include research, testing, or assessment relative to past or present contamination of the site by any source. If such contamination were present, it is very likely that the exploration and testing conducted for this report would not reveal its existence. If the Owner is concerned about the potential for such contamination, additional studies should be undertaken. We are available to discuss the scope of such studies with you. No tests were performed to detect the existence of mold or other environmental hazards as it was beyond Scope of Work. Local regulations regarding land or facility use, on and off-site conditions, or other factors may change over time, and additional work may be required with the passage of time. Based on the intended use of the report within one year from the date of report preparation, AGS may recommend additional work and report updates. Non-compliance with any of these requirements by the client or anyone else will release AGS from any liability resulting from the use of this report by any unauthorized party. Client agrees to defend, indemnify, and hold harmless AGS from any claim or liability associated with such unauthorized use or non-compliance. In this report, we have presented judgments based partly on our understanding of the proposed construction and partly on the data we have obtained. This report meets professional standards expected for reports of this type in this area. Our company is not responsible for the conclusions, opinions or recommendations made by others based on the data we have presented. Refer to American Society of Foundation Engineers (ASFE) general conditions included in an appendix. This report has been prepared exclusively for the client, its' engineers and subcontractors for the purpose of design and construction of the proposed structure. No other engineer, consultant, or contractor shall be entitled to rely on information, conclusions or recommendations presented in this document without the prior written approval of AGS. We appreciate the opportunity to be of service to you on this project. If we can provide additional assistance or observation and testing services during design and construction phases, please call us at 1 888 276 4027. Sincerely, Sam Adetti` Senior Engi Proposed Addition 9965 W 3411 Drive, Wheat Ridge, CO Project No: 0299-D 16 October 22, 2016 Page No: 15 of 15 fes' m 0 CQ CQ Zo o PO �l � Ao a o i M � o ani 4 1 t4 cri rTl C\2 U m 0 � O p CQ O di O O O U p, o� d O po U � � O O a> m a� M � w C P4CU P4 F api o ap ca° De +� p m p m CLF ell �o P4 W w m eo N w A v to p W U cd m z W Cd W A m O �~ W ea 0 A 0 c ai G4 0 0 ami COQ N a baa a O V Off, O ° OHO ° 0 0 o��'�(Z �m V! _ ,p U w +� A U a •N it ,� 00 p N 0 aj U U O U d G � U co O pA �•�+U� twYU-.+ SaO UL,10 o �MGdO i o 00Otko O aS`U 00 00 z E-zo C co F ° i --q w 6 O Q I A •.. o aV, Q r-+ 0.0 Q Lx i aa� Uc! O U a=; 0 � � ad 00 > a � 00 0 .N O O x w U td ,0 0 .:z �zt d' N k k -P O m rr z s Q lti z O O a +�C0 y cd m cd P vUi A cd A O 4. a A N ti id yaw 'F. N 03: C) U p N U ad .,. � a� �0a �� e 'a o H Q b ti ., a ma 0 a� ,. a O z a y a. Z •�' �aq m „ m b oV,;� pay a� ~0 Wmaai 4JId. 0 Co ad a qO �za o .� ,b°' �a0 Cd"0.p+ O ° c O o Cd a 4 o Asti 0 O d �O "tC\1A W0 baa v� C� eat E y U m v Z ��bti m 00 0 T w�a2O� 1-1 N co %4 to vi 0 48 � H °'bay �� •ick. m p o k v N o q pb � � b m•� b ° W w a) O >CQ 03 �7 V cd ^�OD a O O .V. O k O to Cd d tko (0 4' 04 00 o k 0 'd o �, u m D A A d aaki °CD'�, �41O;dw dam, o q rl v +� ami, C o q � � � wb o o �qa,� �n �b c°. a [�[�� 0 U (Da Crn kd W Y2 0 G 6 w .: . . v O m� a z•a ' p.pa� � �� q o p a) m � o 0 0Z yN Om _. E- 0 o tim A� 0 041 SII 0 U] kA A •.�. I 0 {{-, ...... -{ wzo sir g4 CLI to 0) b as mb D m 0 0 o d am.. ocvc. as a-4 w A m e o co 0 0 k q 00 aqi c m q y.,A (L) Cd 0 cd P4 0 0 p .� �yv°, as �U b ami tiw o �ai "'°'� vp, 0 0 \ �"'�. AAE- �w c. g� poi c0. a�DA '0 ��\ A EOA 41 U O q � Sd dm fib°' '� \\��\\\ al.� W o� o+°� m 10 ID U3 M � b ° \ 0 " ll R'. A a� o 'ku cki ami q '0 + C% y m Cd m m +. p I +°� \ ; p fes, V m O ,a q p m ai d mma fir°. d >,°A oo \ m °°''as ani 0 m p.wc;d maw c�, a o a b� ro a ° .� ko o g b aqd ad qtko a 41 aam I b oar �m m .,a� W ad o m q� m w +j aom00'0 $ �° Eoo w0� �d mkz 0 v°vv.$.m �;\ :mow zr+00 c6�bd��� m LABORATORY DATA SUBSURFACE EXPLORATION DATA B1 9965 W. 34th Drive, Wheat Ridge CLIENT: Davies Project Number 0299-D16 Drill Rig: CME 55 Eq. and Williamson Drive Probe (WDP) Geologist/Engineer SMA Ground Elevation Not measured Date Drilled 10-12-2016 Total Depth of Borehole 20.5 Feet Borehole Diameter 4 Inches Depth to Water Not encountered .-. Description / Lithology o ,� a a � C7 A v� o A *4 ri U P Brown crushed rock, existing driveway_ SANDY CLAY to SILTY CLAY, brown, X"", stiff to very stiff, moist, medium to high / plasticity 11 f` 16 1.6% 30 38,18 5 5 0 Xt psf _ CH f / 32 37 39,25 1 41 SILTY CLAY to CLAYEY SILT, olive gray to gray, very stiff to hard, moist, high plasticity (Possibly completely weathered MH siltstone/claystone bedrock) SILTY CLAY, olive gray, hard, moist, 15 X _ high plasticity (Possibly completely weathered claystone bedrock) 40 51,32 � 0 5 N b 68 — Exploration terminated at 20.5 ft due to high 2 WDP blowcounts. Groundwater seepage was not encountered during or at the completion of exploration. AMERICAN CEOSE VICE , LLC 1 (888) 276 4027 Page 1 0 a, 0 oc O r 0 0 opt o 0 %) XIIQAII A.LIaI.LSV Id O 0 M y� �w♦�g�� Q 3 nstrp�Fe _N � 3 bKhWh 00 O MMl -- .-y �u o c A z M W! d a E r/� 0p F �z 6XN •Gt �tiy N o i1i if C m FI x Q Q v w wnd Q a4 x z 0 n a u x a U F k a N M a n. a. 8 v F t np 5 a � 0. 4� .; O U Q G F N a�e oo Q U d — M M C O O iL � F C7 C7 C7 F� a 0 x o o 0 a � I 0 0 SILTY GRAVELS GRAVEL -SAND • VM CLAY" GRAVELS, GRAVEL -SAD_ GC CLAY MXPRS(ANSI31KRAVEL) swWL•tRAIIISANS, CAVIY SNSTiUaRri{PINES (SANp) POORLY -GRADED SANDS, 7i GRAVELLY sArmc7oRra PsaseANn S1 SILTY dA7S, SAND - SILT MRTRPS(ANS1Q5SAt}) CtAYEYSA\DF,SAND - CLAY SC MX17RP3(ANS7+SANY) INORGANIC SILTS AND VERY PIbR SANDS, ROCKQi!<SCLTYa[Mr CLAYSYPNEADORCL+YLY SILTS WIifSH6HS PLASTICITY (ANS137@45) INORGANIC CLAYS OF LOW TO SYMBOLS TOPICAL GRAPH ,ETTER DESCRIPTIONS • ►�s DESCRUMONS . �• �• wecz.'GRAum G7tAYII.S, c7xAVEL \•t• 'SsPOIALxbG YIX�u-xTf#'rUR � DS •e�.O flO►eO.I TRD RlAl 4. E H1{p�5K711Y1.} �••SvC(;� a�wir►.Aiw�7awe•+ti+x t. •Y:� •.� •1QQ- ,• • ,Ly3 1S•o:y SlO•D•�soo0. .Ql as'p� us�: 1(ftVt. r Rs,xaR GRNES (GRAVEL) W GRAYkii, iTPawtiuer- sumNIrTURE$.rrrscx aRNaN3S(aRAVEt) CLMETUM PLASiC17YGRAVE3[Y GAYS, SANDY Q.AYtffiiTY CLAYS, LEAN CLAYS (ANSU t) oL ORGANIC SILTS AN}bRUhdIC SILTY CLAYS aPuwrAsrtcY(nAsM iNQROANiCS23S,lCACPaiSOR MH aumMnc3ous SAND cR SILTY sally(nxs340as) naRcarImmmm CcaAYsoncCH SnAtSCTY(ADSLt) mmm oYORGANIC CLAYS aFMFtiM7a HIaHYiAS717Y,ORtAN7C$IYSS SAT<FMTSWAM3069W71PTxaaREANCC CONT" (SWAMP - • ►�s 7d oR \•t• 'SsPOIALxbG YIX�u-xTf#'rUR � DS •e�.O flO►eO.I TRD RlAl 4. E H1{p�5K711Y1.} �••SvC(;� a�wir►.Aiw�7awe•+ti+x t. •Y:� •.� •1QQ- ,• • ,Ly3 1S•o:y SlO•D•�soo0. .Ql as'p� us�: 1(ftVt. r -+�t►"ir1��w.�*'+.ss•+isl�'r��r+aa�•w 0 �+1• . • � •tt� II��FII� TIQIiIit�t.�lIi Il0��rtI�I. YiII IIl�f lu. l Ip II VaI Il III�I I �I�U�II I 77 a�wir►.Aiw�7awe•+ti+x Descriptive Terminology & Soil Classification I,sboraturyfflicld Testing Definitions for PAploration Logs DD - Dry Density (pct) WD - Wet Density (pcf) Mc - moisture content (0/.) Plastic Limit (%) LL - Liquid Limit (%) PI = Plasticity Index OC = Organic Content (OA) S = Saturation Percent (1/0) SG - Specific Gravity C = Cohesion cb = Angle of1mernal Friction qu - Unconfined Compressive Strength #200 = Patent Passing the Number 200 sieve CBR - California Bearing Ratio VS - Vane Show PP - Pocket Pencuorricter DIP - Drive Probe Wr = Standard Penetration Test BPF - Blows Per Foot (N vahm) SR - Shelby Tube Sample GW - Groundwater RQD - Rock Quality Desido4ficat TP = Test Pit B - Baring RA - Hand Auger V = Groundwater Leveb'Seepap Encountered During Exploration - Static Groundwater Level with Data Measured SPT M91—boas - Standard penetration testing: is parlbitued by driving a 2 -holt O.D. split poon sampler into the undisturbed formation at the bottom ofthe boring with repeated blows ofa 140 -pound pin-guidod hammer fail og 30 inches. Number ofblows (N value) required to drive the sampler a given distance was considered a measure ofsoil consistency. SH Sampling - Shelby tube sawing is pm*nacd with a thin walled sampler pushed into the undistrabod sail to sample 2.0 fed ofsoil. Air In& Exploration - Testing is performed by measuring rate of advancement and samples am retrieved from outtinp. Hand Augur biplaration - Testing is performed uscing a 3.25" diameter auger to advance into the earth and retrieve samples. 60 so X a -540 C k 3 220 K 10 0 Comistaboy ofCohasive SMIS Consistency SPT (OFF) rp (a* Very Soft 0-1 ka than O -Vi Soil 2-4 025-0.5 Medium Stiff 5-9 0.5-1.0 Stiff 9-15 1.0-10 Very Stiff 16-30 2.0-4.0 Hard 30+ ow4A Pelative, Density of Cohesionless Soils �- I Z Very LOOM 0.4 Loose S-10 Mediata Dose It - 30 Dom 31-50 Very Dena Sf)+ Particle Sir l4catification Name Diameter (inchm) Sieve No. Ruck Block >120 Boulder 12-120 Cobble 3-12 Gravel Course 314-3 Fine 1/4-3/4 No. 4 send COMW VS man No. 10 Mem 2.0 nan No. 40 MW 0425 man No. 200 silt 0.075 mm Clay-4.005mmt Drive Probe Explorstiew - This `relative density" exploration device is used to deterrame the distribubon and estimate strength ofthe subsurfim soil and decomposed rock units The resistance to penetration is measured in blows -par -1/2 foot *fan 11 -pound boAtmar Atich 6" fails roughly 3.5 fed driving the S inch diameter pipe into the ipaund. A schematic ofthe drive probe apparatus is included in the sabsurikee exploration portion of the appendix- For a mom detailed deacnption of this geotechnical exploration method, the Slope SOMMYROfemee Guhlefor National pomn in &a United States, Vokans 4 United Stater Lhwar*xag o(Agrieukara, EM -7170-13, August 1994, p. 317-321, CPT Exploration - Cone Penetrometer Explandons consist oftiushing a probe cone into the oath namil the reaction of a 20 -tort truck. IU cow resistance (qc) and sic ave friction resistance (is) an measured as the probe was pushed into the earth, The values ofqc and is (in an noted as ft localized index of soil strength. 0 10 20 30 40 50 60 70 80 90 100 Liquid Limit (%) Page of 4 ft. 8 ft. 4 ft. Drive Prove Schematic Q 6a. Drop Former V2 in. "arbzed Water Pipe Drive Probe To Drii 3/16 h Hole 10 deg. Aport Plate 1•-- 4 in, --A DrI Weld Plate �i +1T�►i� Center Hol 7I8 in. Hole Here Round Stock 7h Weld Plate Here Chamfer 3/16 in. Plate 2 V2 "' Chamfer V16 in Plate Center DrI 7/8 in. Hole 112 in. Merchant C 1/2 in. ;pe Reference: Figure 3.6.1, Appendix 3.6, Page No. 321, USDA EM -7170-13, August 1994, Volume I CORRELATION WILLIAMSON DRIVE PROBE (WDP) STANDARD PENETRATION TEST (SPT) 30- jE1 Dorado (n = 1035 y-0,6462)°"4 Lower Eel 50) R2 0 6803 O�845XQ?474 25- x R20.5761 R x a X 000� Freshwater (n 20 y - 3.364)42 R2 0,5826 15 a a Elk River 1 = 26) RA a Y = 2 1 084x"o* 10 Fe = O_3027 X4 I x EI Dorado • Low Eel 0 0 Freshwater A Elk River 0 20 40 60 I —• —Elk River - - - Lower Eel WDP (blows/it) —Freshwater Et Domo SOURCE: Published literature by W.C. Adams (Hart Crowser, Inc.), R.W. Prellwitz (Bitterroot Geotechnical) & T.E. Koler (El Dorado National Forest). 230 M;t, 20 • o. A* A, 1,*A A A A A 10A. 5 fx 0 to 20 30 40 so 60 Williamson Drive Pro* D (bpo El Domdo N. F. Pscific Lumber Co. Power Rtgrtmiou SOURCE: United States Forest Service, Technology Development Program Website (http://www.fs.fed.us/t-d/programs/im/williamson_drive/correlation. shtml) about the potential for hazardous materials existing at the site. The equipment, techniques, and personnel used to perform a geoenvironmental exploration differ substantially from those applied in geotechnical engineering. Contamination can create major risks. If you have no information about the potential for your site being contaminated. you are advised to speak with your geotechnical consultant for information relating to geoenvironmental issues. A GEOTECHNICAL ENGINEERING REPORT IS SUBJECT TO MISINTERPRETATION Costly problems can occur when other design profes- sionals develop their plans based on misinterpretations of a geotechnical engineering report. To help avoid misinterpretations, retain your geotechnical engineer to work with other project design professionals who are affected by the geotechnical report. Have your geotechnical engineer explain report implications to design professionals affected by them. and then review those design professionals' plans and specifications to see how they have incorporated geotechnical factors. Although certain other design professionals may be fam- iliar with geotechnical concerns, none knows 'as much about them as a competent geotechnical engineer. BORING LOGS SHOULD NOT BE SEPARATED FROM THE REPORT Geotechnical engineers develop final boring logs based upon their interpretation of the field logs (assembled by site personnel) and laboratory evaluation of field samples. Geotechnical engineers customarily include only final boring logs in their reports. Final boring logs should not under any circumstances be redrawn for inclusion in architectural or other design drawings. because drafters may commit errors or omissions in the transfer process. Although photographic reproduction eliminates this problem, it does nothing to minimize the possibility of contractors misinterpreting the logs during bid preparation. When this occurs. delays. disputes. and unanticipated costs ara the all -too - frequent result. To minimize the likelihood of boring log misinterpretation, give contractors ready access to the complete geotechnical engineering report prepared or authorized for their use. (If access is provided only to the report prepared for you, you should advise contractors of the report's limitations. assuming that a contractor was not one of the specific persons for whom the report was prepared and that developing construction cost estimates was not one of the specific purposes for which it was prepared. In other words. while a contractor may gain important knowledge from a report prepared for another party, the contractor would be well-advised to discuss the report with your geotechnical engineer and to perform the additional or alternative work that the contractor believes may be needed to obtain the data specifically appropriate for construction cost estimating purposes.) Some clients believe that it is unwise or unnecessary to give contractors access to their geo- technical engineering reports because they hold the mistaken impression that simply disclaiming responsibility for the accuracy of subsurface information always insulates them from attendant liability. Providing the best available information to contractors helps prevent costly construction problems. It also helps reduce the adversarial attitudes that can aggravate problems to disproportionate scale. READ RESPONSIBILITY CLAUSES CLOSELY Because geotechnical engineering is based extensively on judgment and opinion, it is far less exact than other design disciplines. This situation has resulted in wholly unwarranted claims being lodged against geotechnical engineers. To help prevent this problem, geotechnical engineers have developed a number of clauses for use in their contracts, reports, and other documents. Responsibility clauses are not exculpatory clauses designed to transfer geotechnical engineers' liabilities to other parties. Instead, they are defmitive clauses that identify where geotechnical engineers' responsibilities begin and end. Their use helps all parties involved recognize their individual responsibilities and take appropriate action. Some of these definitive clauses are likely to appear in your geotechnical engineering report. Read them closely. Your geotechnical engineer will be pleased to give full and frank answers to any questions. RELY ON THE GEOTECHNICAL ENGINEER FOR ADDITIONAL ASSISTANCE Most ASFE-member consulting geotechnical engineering firms are familiar with a variety of techniques and approaches that can be used to help reduce risks for all parties to a construction project, from design through construction. Speak with your geotechnical engineer not only about geotechnical issues, but others as well, to learn about approaches that may be of genuine benefit. You may also wish to obtain certain ASFE publications. Contact a member of ASFE of ASFE for a complimentary directory of ASFE publications. ASPS 8811 Colesville Road/Suite G106/Silver Spring, MD 20910 Telephone: 301/565-2733 Facsimile: 301/589-2017 SUBSURFACE EXPLORATIONS SOIL TESTING EARTHWORK MONITORING GEOTECHNOLOGY FOUNDATION ENGINEERING GEOLOGICAL ENGINEERING ROCK MECHANICS EARTHQUAKE ENGINEERING GEOPHYSICS RETAINING WALL DESIGN GEOSTRUCTURAL DESIGN PAVEMENT DESIGN DRAINAGE EVALUATIONS GROUNDWATER STUDIES ENVIRONMENTAL ASSESSMENTS BUILDING ASSESSMENTS CAA �1f 171 (_ti�7ti if N!�: t� `.7I: ��'TY[� fl'R! ✓ttr�\'\. �: �fl �'1 CORRECTION LIST PLAN REVIEW COMMENTS Project Description: Residential garage addition, 2"d story master bedroom, bath and bonus room addition over garage and 1st and 2"d story laundry. 200 amp main service upgrade from 100 amps. Project Address: 9965 W 34th Drive Plan Check No.: 201706354 Permit App. Date: 8/21/17 Plan Check. Expires: 8/21/18 Permit Valuation: $68,000 Adjusted Valuation: $0 Type of Use: Residential Type of Const.: VB Occ. Group: R3/U Fire Sprinklers: TBD No. Stories: 2 Occ. Load: Design Professional: Crown Jade Engineering Phone: (970) 472-2394 Applicant Contact: Mark Benjamin Phone: Same Plan Check Engineer: Dan Schultz Phone: (303) 235-2853 Engineer's Email: dschultz(aD-ci.wheatridge.co.us IX I 16t Review: 9/18/2017 2"d Review: 10/3/2017 3rd Review: X Italic comments ❑Bold Comments BY Appt. t. The project plans were reviewed for compliance with the following codes and standards: 2012 International Residential Code (IRC); 2012 International Building Code (IBC); 2012 International Pluming Code (IPC); 2012 National Electrical Code (NEC); 2016 International Mechanical code (IMC); 2012 International Fire Code (IFC), 2012 International Energy Conservation Code (IECC) The code section references are from the 2012 IRC, unless otherwise stated. • RESPONSE LETTER. To expedite project approval, Please provide a separate written response indicating the sheet number, note number & or detail number where each comment was addressed on the plans. • Cloud and delta all revisions and include in the title block of all pages. • Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. • AF7 ER 2nd PLAN REVIEW: Please call the plan check engineer listed above to schedule a plan review app(?intment, to expedite project approval. • For cleirification of any plan review comment, please call the plan check engineer listed above. Note: Pian checks expire 180 days from date of submittal. CHARLES ABBOTT ASS OCIATES, INC. 3901NTERt OC KEN CRFs(rn't, 3- Fi oco- r HRoOMFIEA 1)._ Co 80021 RA I FRFF: (866)530-4980 EMAIL: WN'W.('AAPROFFSSlONA1S.CY 'til IN Com! I I I 1 1 11'1 1 T I3 r l l I &`, .. j ., ..� i � � :. j.,_, GENERAL. 1. Obtain plan review approval from the following: a. Building Division b. Planning Division (to be verified prior to permit issuance) c. Public Works Department (to be verified prior to permit issuance) 2. All final drawings and calculations, which will be approved for permit issuance, shall be wet stamped and signed by the respective design professional. To be verified prior to permit issuance. (Pending) Plans shall be signed by Rick Graeff or provide letter from Rick Graeff with his seal and signature authorizing use of these plans. sued at the sarne tome, OF separate plans and plan review well be FeqU'Fed feF items net issued with thi6 eview. SepaFate PeFrnit(S) is � are Fequired f9F aGGesseFy buildings, swimming peels, retaining walls, es no A4 with sheet ;6. erg CHARLES ABBOTT ASSOCIATES, INC. 3901NrnRLOCKIIN CRCSCCNi.3" rLOOR• BROOMfIIt1D. CO 80021 "roil FRF r:(866)530-4980 EMAIL: N'WN'.('AAFROFESSIONALS.C'OM CAA CONSTRUCTION AND MISC DETAILS H. On every level of a dwelling nit ineluding basements. In each sleepipg r W. Outside nosh separate sleeping area iR theviGinity of the herlrnnms 15. Roof dFaiRage shall have a GE)RtF011ed methed of wateF disposal ftem roofs that will Gel!eGt and daSGhaFg& FGef dFainage to the gFOURd suFfaGe at least five feet away 9F W an appmVedl dFaiRage systwn. See P61b'*G- WOFks FeqUiFemeRtS n plans /1R(` R8014) MECHANICAL (2012 International Mechanical code IMC and International Residential Code IRC) veFtiGall IeRgth of the exhaust vent shall Rot e)(Geed 35 feet iR aE;GordanGe with IMG 504.1, 604.9 and table 604.8.4.1 18. PFE)Yide manwfaGtuFeFs speGifffiGatiGRS Gf the wall HVAG LARits. Go! fired YeRted wall fUFRaGes shall Gemply with 1L 730. ELE(:TRICAL (2014 NATIONAL ELECTRICAL CODE NEC) 119.26 (A)(!) +h F9Ugh (F=)(1) and a v nth C..nel (NEC 230.70(A)(1)). where installed WithiR 6 feet of a bathtub 9F sheww stall, within 6 feet of the edge of a GiRk, garages and CHARLES ABBOTT ASSOCIATES, INC. 3901rmrRI ocKF.N CRFscr.NT, 3"' FLOOR- BRI owlr7 n, Co 80021 Toii FRFF: (866)530-4980 EMAIL: WWW.C'AAPROFF,SSIONALS.C'OM CodA it 1'I N I, I F IV I RN - I I iRf Nq11 (.1 ASI '�I 22. PF9vide a switGh an xterieF light at d9GF entFanGe at the de6k. F=9F dwelling units, attaGhed garages and detaGhed garages with eIGGtFiG poweF, at least one wall 6WitGh GGRtrolled lighting eutlet shall be *RGtalled W pF0Vide illumination on the exteFieF side of outdOOF eRt . t With gFade level aGGess. A vehide dOOF OR a garage shall not be GE)R6'deFed as aR EmtdOOF entFanGe eF exit. ExteFiGF lights shall be high 23. Netethat shall be listed as weatheFpFeogtampepresistant." 24. Add to eleE#iGal notes that ail "Rew Feeeptad% Shall be as listed tamper Fes'MaRt." (NEC 406.12) Plumbing (2012 INTERNATIONAL PLUMBING CODE IPC) 26. All Rew PIUMbiAg fiXtWe flows rates shall GGIMply With seG 403 and 408 IPG. b. KitGheR faweets 1.8 gal maximum e. Lavatwy faUGets 1.5 gal maximum a. ShoweF head6 2.0 gal INTERNATIONAL ENERGY CODE 28. Note an the plan6 nGt IeS6 than 0 of the Iarnps installed in permanently installed light fiXtWeG 6hall be high effiGaGy Structural CHARLES ABBOTT' ASSOCIATES, INC. 390 IxrFRI-0( KEN ('RES( ENT. 3`° ROOM BROOM IrI r), CO 80021 Tol 1_ FIR FF: (866) j30 -49x0 - EMAIL W'WW.CAAPROFESSION ALS. COM City of Wheat Ridge r 4000 r- Residential Roofing PERMIT - 093028 PERMIT NO: 093028 ISSUED: 10/06/2009 JOB ADDRESS: 9965 W 34TH DR EXPIRES: 12/31/2010 DESCRIPTION: Reroof 24 sqs * ** CONTACTS * ** owner 303/237 -2448 Ross Westover sub 303/238 -7663 James Roberts 09 -0391 Roberts Roofing ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0740 BLOCK /LOT##: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 7,220.00 FEES Extend Expired Permi 99.65 Permit Fee 199.30 Total Valuation .00 Use Tax 129.96 ** TOTAL ** 428.91 Conditions: 6 nail installation & mid -roof inspection required. Board sheathing spaced more than a 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from save edge to 2' inside exterior walls. ** *Contractor /Property owner shall provide ladder(s) secured in place for inpsections. Subject to field inspection. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. Signature of contractor /owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty -four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6.. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval Rf, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. A11 1 r w is subject to field inspections. Signa e CUChief Building Official date INSPECTION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS AY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 111�DA V�D� c ' Sid iD�ll � C f' M September 22, 2010 City of Wheat Ridge Attn: Building Division 7500 W.2W Avenue Wheat Ridge, Colorado 80033 -8001 Re: Permit Renewal: #093028 — 9965 W. 3e Drive Dear Sirs: Please find enclosed our company check in the amount of $99.65 representing the fee for renewal or reactivation of the permit fee for our roof construction work on the above address in Wheat Ridge. Please accept the same so that we may shortly call your department for scheduling the final inspection of this residence. Please feel free to communicate with me at your convenience if you need any further information in order to accept and post the above payment to this permit file. V CITY OF WHEAT RIDGE 09/27/10 3:48 PH edba Controller Roberts Roofing Roberts Roofing & Construction, LP 918 -770 -4323 (Direct Line) RECEIPT NO:CDA005088 AMOUNT 918- 770 -1743 Cell DPSP Reroof 24 sgs 99.65 ( ) 093028 Email: davidforbesnarobertsroofing_us Extend Expired Perri 99.65 PAYMENT RECEIVED AMOUNT CK 4888 99.65 TOTAL 99.65 s� - C Vm o� V4,k)o- u"' P cSl - �- xw j�1jc6 1 nyo l m , Office 628 -Roof (7663) 4 Fax 280 -9802 4 www. robertsroofing. us 7634 East 46` Place Tulsa, OK 74145 ♦ i CITY OF WHEAT RIDGE Bung Inspection Division I (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type 4 _ Job Address: (V "F)L~ i R Permit Number: <5 z ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No *When corrections have been made, call r inspection at 303-234-5933 Date L~ Inspector` DO NOT REMOV THIS NOTICE City of Wheat Ridge r4ooor Residential Roofing PERMIT - 093028 PERMIT NO:- 093028 ISSUED: 10/06/2009 `JOB ADDRESS: 9965 W 34TH DR EXPIRES: `04/04/2010 DESCRIPTION: Reroof 24 sqs CONTACTS owner 303/237-2448 'Ross Westover sub 303/238-7663 James Roberts 09-0391 Roberts Roofing **PARCEL .INFO ZONE CODE: UA USE: UA SUBDIVISION: 0740 '-BLOCK/LOT#: 0/ **-FEE SUMMARY ESTIMATED PROJECTVALUATION: 7,220.00 FEES Permit Fee 199.30 Total Valuation ,00 Mai Use Tax 129.96 j **:TOTAL 329.26 Conditions: 6 nail installation mid-roof inspection required. Board sheathing spaced more than 'a 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from ,eaveedge to 2'-inside-exterior walls:.' ***Contractor/Property owner shall provide 'ladder(s) secured in place for. inpsections. Subject to field inspection. Ihereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable `ordinances, rules or regulations of the City. of Wheat Ridge or'covenants, ..easements or restrictions of record;: that all measurements shown, and.: allegations made are accurate;. that I.have read and agree' to abide by all conditions printed on this application and,--qt I 7e~assume full responsibility for compliance with the Wheat Ridge Building Code :(I.B.C). and all other. appl Wh t i rdinances, for work under this permit. Plans subject to field inspection. /D •Lv G 9 6ignature of contractor/owner 'date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the state of Colorado and to the zoning Regulations and Building Codes of wheat Ridge, Colorado or any other applicable ordinances of the City. 2 This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3 :If this permit expires,ra new permit may be acquired for a fee ofone-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment :exceeds one (1) year, full fees shall be paid for a: new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage. problem. i. Contractor shall notify.. the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding. with successive-phases of the job. The issuance of a permit or the approval of 'drawings and specifications shall not be 'construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any :other ordinance, law;.. rule or regulation. All. plan revie i ject to field inspections. 0 Signature of~ of `ilding:Official date CNSPECTI REQUEST LINE: (303)234-5933 BUILDING OFFICE': (303)235-2855 REQUESTS MUST BE is MADE BY-3PM ANY ,BUSINESS :DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.':' City of Wheat Ridge Building Division Date: 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-235-2857 Plan M ° a Inspection Line: 303-234-5933 O<ORPO Permit Building Permit Application Property Address: /.~5 i ?Z/ t!~ 1J2 Property Owner (please print): fCOSs l~='sr^y✓~ ~ Phone: 303 - r33~- a~/~/B Mailing Address: (if different than property address) Address: City, State, Zip: Contractor: _ i2plg5,;s 12X~-0F vt- ~~Si 2uCi ^D~ Contractor License 09031?/ Phone: 503 - a39- 2603 Sub Contractors: Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ -7, l~6 Description of work: (as calculated per the Building Valuation Data sheet) +/~oer Plan Review (due at time of submittal): $ Sq. Ft./L. Ft added: Squares 1;V4 BTU's Gallons Amps OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. C/RLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) PRINT NAME: SIGNATURE: Date: ZONING COMMENTS: Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer. :BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY: FIRE DEPARTMENT:: ❑ approved w/ Comments ❑ disapproved 0 no review required 4HA City of Wheat Ridge Residential Fence PERMIT - 060977 PERMIT N0: 060977 ISSUED: 10/12/2006 JOB ADDRESS: 9965 34TH DR EXPIRES: DESCRIPTION: 4 foot retaining wall - see attached site plan/detail CONTACTS owner Ross Westover gc 303/974-8088 Jeff Workman Artscapes PARCEL INFO - ZONE CODE: R-1 USE: UA SIIBDIVISION: UA BLOCK/LOT#: 0/ FEE SUMMARY Permit Fee Plan Review Fee Total Valuation Use Tax TOTAL ESTIMATED PROJECT VALUATION: FEES 126.50 82.23 .00 O~a' lv-l 72.00 280.73 4,000.00 Comments: fence cannot exceed 6 feet in height in back yard, and cannot exceed 4 feet in height past front wall of house subject to field inspection i hereby certify that the set ack distances proposed by this permit application are accurate, and do aot violate applicable ordinances, ru l s o egulat s of tCity of Wheat Ridge or covenants, easements or restrictions of record; that all ions made are accuratethat i have read and agree to abide by all conditions printed on this measurements s wn an all 'he pplon a th su e ull reponsbilty for compliance with the wheat Rid9e Building Code (I.B.C) and all other ap e R di es, for work under this pesmit. Plans subject to field inspection. . date I. This permi~t was iasued in accordance witri the proviaions set forth in your application and is subject to the laws of the State of C~lorado and to the Zoning Regulations and Building CodesoE Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This pezmit shall expire if (A) the work authorized is not mmmenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or.will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. , 4. No work of any manner ahall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval oa inspection card before proceeding with successive phases of the job. 6. The issuance of'a permit or the approval of drawings and specifications shall notr be construed to be a permit for, nor an approval of~ ny violation provisions of the building codes or any other ordinance, law, rule or regulation. All plan reydia sub~t f~Inspections. . Signature(,wf'Chief Buildingt £fical date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ~ K0~! Owiet/eOnhoEorbrespoasibleforlaxtMgproperty ' N= md COUSUwdng impmvements according to the ePproved plan and tequired development standards. The City is not tesponsible for inaccuratc information submltted wlthin the plan set and any construction ercors resulting from inaccurate informa;ion. oF WHEqT Plan Review #~(~j ~ Po City of Wheat Ridge Building Permit Number: ~ ° Community Development Department Date: ~oCORA00 XC-'4.Sd~ C OR B(~~~INGP~.~S.R ~~PLI1,ATl'Ol.C' Property Owner: ' 4~~ (~~~~~f£ e PropertyAddress: qq(oS GJ 3q'* (2o bL-033 Phone: qq Contractor License No.: ~ R`"~~--~'~ U~~ i ComP~Y: A~SCVZ-P'S ~hone: ~/n'(oe ' ~~etc-~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ( guildinq Dept. Valuafion Figure: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicabie ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by ali conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all otherapplicable Wheat Ridge Ordinances, for workyoder Ni; perrpkPlpns subject to field inspection. (OW NER)(CONTRACTOR): Value:$ Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ a- Use of Space (description): -~vNfl Descriptionofwork: - aL't>C.Y_ Sq. Ft. added 60- Lnitnv`A «Uk jg~ l 1`- cY ~ 1^„~' rBUILDING DEP COMMENTS: TMENT USE ONLY Approval: Zoning: nj G COMMENTS: ~r ApprovaC WORKSCOMMENTS: ~ r~ Approval: ~ c DEPARTMENT COMMENTS: Approval: Walls: Roof: Stories: Residential Units: Sq. Ft.: Electrical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subjectto the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within si#y (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specifcations and any suspension orabandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Conhactor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and speciFications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, ruie or regulation. All plan review is subject to field inspections. Chief Building Official r" ylid - ~p yp•_ i_ . , 3o O I _ DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 12951 BUILDING INSPECTION LINE - 303-234-5933 Date : 10112/01 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner Property Address : 9965 W 34TH DR Contractor License No. : Company: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable at Rid e rdinances, for work under this pe~~~rm~itJ. (OWNER)(€OIdfi~OR)SIGNF , ~r./DATF~/~~1~~C/O/ ~ / Phone : 237-2448 Phone : Construction Value : $2,000.00 Permit Fee : $69.25 Plan Review Fee : $0.00 Use Tax : $50.00 Total: $119.25 Use: Description : REPLACE AN EXISTNIG CHAIN LINK FENCE WITH 6' HIGH CEDAR PRIVACY FENCE. CHAIN LWK FENCE WAS DAMAGED BY MISCHIEF. BUILDING DEPARTMENT USE ONLY ifl~~~, SIC : Sq. Ft. : Approval : MLC COMPLIES W/ FENCE REGS Zoning: R-1 P1E'EQNOtet pyyner( eonusetor is responsible for locating property ffi ~ ~ '"~~n?~. 10/11/01 lines and consltucNng improvements according to the Approval : BG approved plan and required development standards. The City is not responsible for inacwrate information S,~' 'i~1`~~t0 submitted witttin the plan se[ and any construction Approval : errors resulting from inaccuratc informe?ion. Occupancy : Walis : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company: Company; Company: Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: (1) This permit was issued in accordance with the provisions set forfh in yopur application and is suhjec[ to the laws of the State of Colorado and to the Zoning Regulations and euiltling Code of Wheat Ridge, Coloredo or any other applicable ordinances of the City. (2) This pertnit shall expire if (A) the work authorized is not commenced within sixly (60) days from issue date or (B) the building authorized is suspendetl or abandoned for a period of 120 days (3) If this pertnit expires, a new permit may be acquiretl for a fee of one-half the amount normally requiretl, provided no changes have 6een or will be made in the original plans and specifca[ions and any suspension or abandonment has noF exceeded one (1) year. If changes are made or if suspension or a6andonment exceeds one (7) year, full fees shail be paid for a new permi[. (4) No work of any manner shall be done thaiwill change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspectortwenty-FOUr (24) hours in atlvance for all inspeclions antl shall receive written approval on inspec[ion card 6efore proceediing with successive phases of thejob. (6) The issuance of a permit or the approval of tlrawings and specifcations shall not be construetl to be a permit for, nor an approval of, any violation of the o sion of [ uilding cotles or any other ordinance, law, rule or regulation. "IYffn'a=a Chief Building Inspector oF WHEqr DES.'ARTMENT OF PLANNING AND bEVELOPMENT Buildiag Permit Number: y BUILDING IN5PECTION LINE - 303-234-5933 Date: CTI`Y OF'WHEAT RIDGE 7500 Vi'EST 29TH AVENLTE WHEAT RIDGE, CO 80215 - (303-235-2855) C~C ORP~O ,y 4~ ,{~PIJ4~iddN~lY pr5~pp~ 7~~ . Property Owner: F<6,s we,-4oet' PropertyAddress: G1G~~~ 3!{~~~~~1~~~80~33 Phone:3O3 ;~37-o1`Lf~ Contractor License No.: Company: Phone: OVlNER/CONTRACLOR SIGNATURE OR UNDERSTAImING AND AGREEhIENT L hereby certify that the setback dista¢ces proposed by this permit applicatioa aze accutate, and do ¢ot vio[ate applicahle ordiaanccs, niles or regutafions of the City of A'heat Ridge or covcnants, easemc¢ts or restrictioas of record; that afl measucements shown, and aliegatioac made ace accutate; that I fiave road aad agrcc tq abide by a11 4lheatRidge Oidinaaces, for workvadci this petmit • Construction Value: ~a~ Q~p o0 co¢ditions priated on Uus applicatio¢ andthak I assume full responSi6ility_for wmpGaace with the Wheat Ridge Building Code (UB.G) and a11 other applicable Use Tax: Tota1: (OWNERXe&?_f 52kff WE;: SIGt]ED ✓ - DAIE~~~ Description: f;~7bce av~ ~tA'ng ~+am I ink -gy-tce ~t`~-h ,'h,9h ~clarprivacy.-~ce.~~ cl~a~n li,nk r~eeWas ~ dainaqed hv a-LTltschleF mis.ehie< ' SUILDING DEPARTNIENT USF ONLY ZONING COMMENTS: ?.pprovaL• Zon.ing: 6UfLOING COMMEN75: Approval: ~~~~,kl PUBLIG WORKS COMMENTS: ApptovaL Occupancy: Walls: Roof: Stories: Electrical License No: Plumbing License No: Company: Company: ~ , , O,~ . y ~ k-- ! J -~~."'4 G~•~ L.:l ' ~ ~ F Mechanical License No: Company; ExpirationDate; ExpirationDate: ' ExpirationDate; Approval: Approval: Approval: (I) T(us peimit waz issued in accotdance with Ne provisions set foRh in yout applicafiba a¢d is Yu6ject to the laws of the SGte of Colomdo aad to the Zoning Regulafloas and Building Codes of Wheat Ridgq Colorado or any othcc appficable ordinancu of flm City. (2) This pamit shall exp¢e if (A) the work authodzed is noC commeaced wifhia sixcy (60) days Eom issue date or (B) the building authodzed is suspended or a6audoaed for a periad of 120 days. • (3) If tltis permit cxpsu, a new petmit may be acquired foc a fee oFone-hak'tlte amouac rtocmatly required, provided no changes have bee¢ or WiLL be made i¢ th<ori=~iaalplans and specificado¢s aad any sutpension or abando¢menthaz nof exceededone (1) yeaz. If chsages havnbeen or ifsaspeosiouoraba¢doome¢t exceed3 one (1) yeaz, fiili fees shaLL be paid for a uew pttmit - (A) No work of any manner shalt he doae thac will change the natucal flaw of wafec cau:ing a drainage pcoblem. (5) Co¢traelorshallnoGfyNeSuildingInspcctortweaty-fout(24)hou[sinadvan<efocallinsoectlaaaa¢dshallreceivewdtteaapprovalonmspec¢oncardbefore praeaedi¢g with suecesaive phazu of the job. (6) The issaance of a pecmit or the apomval of dcawings and specificafions sha11 wt 6c coashued fo Se a oetmit for, oor m approvat of, aay violatloa of ihe . . pcovixions of tLe building codn or any oth<r ocdiaance, law, rv1e or regulaton. . . Chief B ' ding Inspector roie~ I = ~`i¢Jd M¢asur¢d 4 DraWn61i~.1ot• Prow ole . Y_ III i ~ I yl ii NII i ~ ~I i w z } F- ct: aiu ~ a 0 cc ~ fncr{~+~ Rxh COMW Falee Elitt' i - I . . . . 89'O". 92'- o' 93'-O' 9Ei- O" =fSFIRST F'=RE_EV. 100'70". ~ 97= 0" ~ CqRL~VEL=D DF21V~ INCIN T =q• y J U ;~as uE E IRKT D ~ J2o/~ i / W I Q I . ' EL6 i~ . u0; in j O z ~i J Ici a I :p a 4 . 4 99 ~ _ 4"SEWER . . ~ . ~ • ~ PC! 101~_~~. . . . . :NCI.I A4ARG: I ~ ~ 4 eR „aP ~ ~ r LD LJT PLAN ~IAII^I I. i-i',••-Jhl' . . DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING WSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : 95-1329 Date : 7/5/95 Properly Owner : WESTOVER F ROSS Property Address : 9965 34TH DR Contractor License No. : Company : Phone : 237-2448 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certiy that the setback distances proposed by this permR application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurete; that I have read and agree to abide by all cond@ions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for wor d71 is p rmit. (OWNER)(CONTRACTOR) SIGNED" ~ DAT Description : REROOF BUILDING DEPARTMENT USE ONLY Fw>... O~„~w.`:2..E.t Approval: Zoning : :~a:::.a•K,ss::::,...:a`;; Approval : Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: . xa:s~~~~.~.~'.,,'~FI~~a=yy~ :~M;' .v (1) This permil was issued in accordance wflh ihe pmvisions set forth in yopur application and is subject to the laws of lhe State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of Ihe City. (2) This pertnit shall expire if (A) the work authorized is not commenced within sixty (60) days fmm issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permR expires, a new permd may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in ihe original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension ar abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall he done ihat will change the naturel flow of water causing a drainage problem. (5) Contractor shall notiy the Building Inspectartwenty-four (24) hours in advance for all inspedions and shall receive written approval on inspection card before (6) 'i17~ ~ssuance of a permit or the approval ofdrawings and specifications shall not be construed to be a permd for, nor an approval of, any violation ofthe p(oSJsion;oHhe buildipg codes oq,eny othgr oroinance, law, rule or regulatian. Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Construction Value : $1,000.00 Permit Fee : $25.00 Plan Review Fee : $0.00 Use Tax : $25.00 Total: $50.00 c(~Zo DEPARTII~ENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDlNG INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date :,J(a~V S~ IqQS 7500 WEST 29TH AVENUE ~ WHEAT RIDGE, CO 80215 -14~ Property Owner : FPO55 ~E le a n o r J, Ules~ ave r -74 PrQperiyAddress:qQcS W, 34A?Dr Phone:a37-a448 Contracior License No. : NQ Company: N A Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value 4( I hereby certify that the setback disfances proposed by this permit application are acwrete, l l d d t i l t li bl di ti f th Ci f Wh t Rid ~ P@ffl'llt F2B : nances, ru es or regu an o no v o a e app ca e or a ons o e ry o ea ge or covenants, easements or restnctions of record; that all measurements shown, and allegations made are accurate- ihat I have read and agree ta abide by all conditions printed on this Use Tax : aS application, and that 7 assume full responsibility for compliance with the Wheat Ridqe Building Code (U.B.CJ and an;other applicable INheat Ritl ordmance§, for work under this permit. -~~~-r~ Total ~ (OWNER)(CONTRACTOR) SIGN ATE~ r / X Description :*CCI l!'1( C,7'T Qt7cvG r~ s i d en c~ Electrical License No : Plumbing License No : Mechanical License No : Company : Company : Company : Expiration Date : Expiration Date : Expiration Date : Approval : Approval : Approval : ci t~~~d (1) This permit was issuetl in accordance with the provisions set krih in yopur applica[ion and is subject to the laws of the State of Colo2do antl to the Zoning Regulations antl Builtling Code of Wheat Ritlge, Coloredo or any other applicahle ortlinances of the City. (2) This pertnit shaN expire rf(A) the work aufhonzed is not commencetl within sixry (60) days trom issue date or (B) the building authonzetl is suspendetl or abantloned far a penud of 120 tlays. (3) If this permi[ expires, a new pertnit may be acquiretl for a fee of one-half the amount nortnally requiretl, provitled no changes have been or will be made in the original plans and specifiwtions antl any suspension or a6antlonment has not exceeded one (t) year. If changes are made or if suspension or abandonment exceeds one(1) year, full fees shall6e paitl for a new permit. (4) Mo work of afoy manner shall be done iha[ will change the naWral flow of water causing a tlrainage problem. (5) Contractor shall notiry the euiltling Inspector Iwenry-four (24) hours in advance for all inspections and shall receive written approvai on inspec6on cartl 6efore proceetliing with successive phases of the job. (6) The issuanceoTa permit orthe approval of tlrawings antl specifiwtions shail not 6e construed to be a permit tor, nor an approval ot, any viola[ion of the provisions of the 6uiltlirg rndes ot any othet ottlinance, law, rule or regulation. Chief Builddng Inspector For Mayor THIS PERIVIIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION