HomeMy WebLinkAbout11301 W. 40th Avenue� ► � i City of Wheat Ridge Residential Addition PERMIT - 202100738 PERMIT NO: 202100738 ISSUED: 06/15/2021 JOB ADDRESS: 11301 W 40th Ave EXPIRES: 06/15/2022 JOB DESCRIPTION: Living Room Addition with crawlspace, extending existing HVAC and Electrical. Remodel existing kitchen, laundry and master bedroom suite. 500 sq ft *** CONTACTS *** OWNER (303) 421-3334 FISHER LEE E GC (303)903-1790 PETE REGALADO 110221 REGAL CONSTRUCTION INC. SUB (303)781-1241 ALLEN HANCOCK 018098 CREATIVE ELECTRIC SUB (303)455-4307 GREG BARBERO 017178 GOOD PLUMBING SERVICE CO., INC SUB (303)667-5174 DAVID ELLERD 022300 FOREMAN HEATING & COOLING INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 134,410.00 FEES Total Valuation 0.00 Plan Review Fee 882.57 Use Tax 21822.61 Permit Fee 11357.80 ** TOTAL ** 51062.98 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. In addition, no less than twenty-five percent (250) of the gross lot area and no less than one hundred percent (1000) of the front yard shall be landscaped. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development Code. All landscaping shall be installed in accordance with the approved landscape plan prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 1250 of the cost of the installation shall be required. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Addition PERMIT - 202100738 202100738 ISSUED: 06/15/2021 11301 W 40th Ave EXPIRES: 06/15/2022 Living Room Addition with crawlspace, extending existing HVAC and Electrical. Remodel existing kitchen, laundry and master bedroom suite. 500 sq ft I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this,permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/15/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. h ave nothimed uptshol June 1st,2021 Attached please find the resu@s of asbestos test samples taken for Schuyler Cayton at 11301 W. 40' Avenue in Wheat Ridge, Colorado on May 2E", 2021: The area to be disturbed was homogeneous and between 1,000 sq.tt. and 5,000 sq.tt., so five samples were taken, each from a different room. Please let me know if you have any other questions. JERRY HARC K, PLS TURNSTONE HOME INSPECTIONS 385 WHITE ASH DRIVE GOLDEN, CO 80403 720-563-1008 JERRY(dTURNSTONE-LLC.COM W W W.TURNSTONE-LLC.COM tiff eurofins i EMLab P&K Report for: Jerry Harchek Turnstone Home Inspection Services 385 White Ash Dr Golden, CO 80403 Regarding: Project: 09-15-20 4p; Drywall Test 11301 W 40th Ave EML ID: 2482426 Approved by: Approved Signatory Amber Rutter Dates of Analysis: Asbestos PLM: 09-17-2020 Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM -AS -S-1267) NVLAP Lab Code 500053-0 All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1 % asbestos concentration can be provided when requested. Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor. EMLab P&K, LLC EMLab ID: 2482426, Page 1 of 2 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Turnstone Home Inspection Services C/O: Jerry Harchek Date of Receipt: 09-15-2020 Re: 09-15-20 4p; Drywall Test 11301 W 40th Ave Date of Report: 09-18-2020 ASBESTOS PLM REPORT Location: A, End of hall -East Total Samples Submitted: 1 Total Samples Analyzed: 1 Total Samples with Layer Asbestos Content> 1%: 0 Lab ID -Version$: 11831712-1 Sample Layers Asbestos Content White Compound with Paint ND Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2482426, Page 2 of 2 Please see redline comments noted on the structural drawings. / �gb Pybott gssoc'. Ura df`Ds CAAAA `. 0 PLAN NOTES REMOVE ALL WALLS, WINDOWS, DOORS, FLOORING, CABINETRY, COUNTERTOPS, PLUMBING FIXTURES AND ACCESSORIES, LIGHTING, AND MIRRORS UNLESS NOTED OTHERWISE. 1. MAINTAIN EXISTING WOOD FLOORING. 2. REMOVE DOORS AND PREPARE OPENING FOR INSTALLATION OF NEW DOORS. 3. REMOVE EXTERIOR BRICK, BUT MAINTAIN EXISTING FRAMED WALL. 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL DEMO PLAN SCALE: 1/4" = 1'-0" DRAWN BY: M DAOUST DATE: 1/12/2020 REVISIONS: 1/17/2020 MODIFIED WALLS TO BE DEMOED NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. DRAWING NO: Al . l / �gb Pybott gssoc'. Ura df`Ds CAAAA it, 5/8 1 15/8 1 15/8 7'-1 0" 8' 7'-1 0" 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL CONSTRUCTION PLAN SCALE: 1/4" = 1'-0" DRAWN BY: M DAOUST DATE: 1/12/2020 REVISIONS: 1/17/2021 MODIFIEDWALLSTO REMAIN DURING CONSTRUCTION 4/15/2021 EXTENDED GREAT ROOM, ENLARGED SLIDING DOOR AND WINDOWS NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. DRAWING NO: A1,02 / �gb Pybott gss00, Ura df`Ds CAAAA it,`y`�c �,,�ng Dv,��` 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" D RAW N BY: M DAOUST DATE: 1/12/2020 REVISIONS: NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. 0rel A2.1 / �gb Pybott gss00, Ura df`Ds CAAAA it,`y`�c �,,�ng Dv,��` 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL FINISH PLAN SCALE: 1/4" = 1'-0" D RAW N BY: M DAOUST DATE: 1/12/2020 REVISIONS: NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. 0rel A3.1 NUI L: ALL 5W1 I C M t5 AKL IU bL MOUNTED AT 48" A.F.F. O.C. OF BOX AND DIMMABLE UNLESS OTHEKW15E NOTED. P+ WALL -MOUNT LIGHT FIXTURE 0 RECE55ED LED Q RECE55ED LED, DAMP ® FAN CEILING LIGHT CEILING FAN SINGLE ROCKER SWITCH f3 3 -WAY ROCKER SWITCH f4 4 -WAY ROCKER SWITCH ALL LIGHTING LOCATIONS ARE CON51DERED APPROXIMATE AND TO BE DIRECTED DY SITE CONDITIONS AND EXISTING STRUCTURAL COMPONENTS. / �gb Pybott gssoc'. bra CAAAA �`y`�c gD 7` 0 MEGAN DAOUST L I V E B E A U T I F U L L Y CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0" DRAWN BY: M DAOUST DATE: 1/12/2020 REVISIONS: 1/17/2020 MODIFIED HALLWAY RECESSED LIGHTS, ADDING DINING ROOM SWITCH NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. 0rel A3.1 f- 8I-5/4ll 7" 1 HALLWAY ELEVATION SCALE: AS NOTED 3'-1 0/4 L 71-33/411 I, 31-5/211 5 DINING ROOM ELEVATION SCALE: AS NOTED 4' V / 1 83// 83// P-4 OPEN TO ENTRY C-3 Fk-2 a a a ° ° ° a 4 ao ° a 5,/,11 V 6 DINING ROOM ELEVATION SCALE: AS NOTED 141- 101211 9 ISLAND ELEVATION SCALE: AS NOTED 3'-6" 10 ISLAND ELEVATION SCALE: AS NOTED 3'-6" 3'-5/2" 21-1 1" � 2'-6" 71-1 1" 6" 2 HALLWAY ELEVATION 3 HALLWAY ELEVATION SCALE: AS NOTED SCALE: AS NOTED 5'-05/8 4'- 101211 1 '-5/2" DINING ROOM ELEVATION SCALE: AS NOTED 11 ISLAND ELEVATION SCALE: AS NOTED 4'-6" 6/4 14 FAMILY ROOM ELEVATION SCALE: AS NOTED 151-53/ 8 3' 4'-V8" .o 2'-6" ---� 11-211 � 2'-4" 6'-4" 63 00 21-GllI. 8' L 2_03/4 4 DINING ROOM ELEVATION SCALE: AS NOTED 1014 g KITCHEN ELEVATION SCALE: AS NOTED 141- 101211 12 ISLAND ELEVATION SCALE: AS NOTED 19, 4' 101411 / �gb Pybott Ass, Ura df`Ds CAAAA `. 0 EQ 7'- 1 O" EQ 8' EQ 71-1011 EQ 28'_V2" 13 FAMILYEROOM ELEVATION 71-33/411 L 31- 1/2 15 FAMILY ROOM ELEVATION SCALE: AS NOTED 12' 4'-6" 01 4" 6/4 a 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL INTERIOR ELEVATIONS SCALE: 3/8" = 1'-0" DRAWN BY: M DAOUST DATE: 1/12/2020 REVISIONS: 1/17/2020 REVISED ELEVATION NUMBERS AND REMOVED DUPLICATE ELEVATION NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. DRAWING NO: A4.1 C-3 Fk-2 a a a ° ° ° a 4 ao ° a H OPE TO L OPEN TO ALLWAY AY / \ tiA-3 L1\1 FA-J] LF - 1014 g KITCHEN ELEVATION SCALE: AS NOTED 141- 101211 12 ISLAND ELEVATION SCALE: AS NOTED 19, 4' 101411 / �gb Pybott Ass, Ura df`Ds CAAAA `. 0 EQ 7'- 1 O" EQ 8' EQ 71-1011 EQ 28'_V2" 13 FAMILYEROOM ELEVATION 71-33/411 L 31- 1/2 15 FAMILY ROOM ELEVATION SCALE: AS NOTED 12' 4'-6" 01 4" 6/4 a 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL INTERIOR ELEVATIONS SCALE: 3/8" = 1'-0" DRAWN BY: M DAOUST DATE: 1/12/2020 REVISIONS: 1/17/2020 REVISED ELEVATION NUMBERS AND REMOVED DUPLICATE ELEVATION NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. DRAWING NO: A4.1 3- 114" I ' � 11-311 � I '- I I " I '- I I " 0/4 3'- 10" 1 BATH #1 ELEVATION SCALE: AS NOTED 6 BATH #2 ELEVATION SCALE: AS NOTED 5'-7�4" 3- 112" 5N- I S-2 <o )ES, TOP$ BACK m S -I CP $ FRONT OF 2'-8" CUP.e 43/4' J934�� 5Y4 2 BATH #1 ELEVATION SCALE: AS NOTED PF- 12 PF- I PA -5 N P-8 M-2 PA -7 - � - F-1 3 S-3 D -I O a a a a m S -I CP $ FRONT OF 2'-8" CUP.e 43/4' J934�� 5Y4 2 BATH #1 ELEVATION SCALE: AS NOTED PF- 12 PF- I PA -5 N P-8 M-2 PA -7 - � - F-1 3 S-3 PF -7 m C-5 2'-6" 11-01 --� 11-01 2'-7/2" BATH #2 ELEVATION SCALE: AS NOTED 2' 3' g BATH #2 ELEVATION SCALE: AS NOTED 31-1011 4 _214 2' 3 BATH #1 ELEVATION SCALE: AS NOTED 0-53/4" 11-511 � 1 '-5" �' 4 BATH #1 ELEVATION SCALE: AS NOTED m 2'-7�2" �� 2'-6" 6" 5 BATH #2 ELEVATION SCALE: AS NOTED / �gb pbbott Ass, Ura df`Ds CAW �4��a `. 0 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL INTERIOR ELEVATIONS SCALE: 3/8" = 1'-0" D RAW N BY: M DAOUST DATE: 1/12/2020 REVISIONS: NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. DRAWING NO: A4.2 / �gb Pybott gss00, Ura df`Ds CAAAA it,`y`�c �,,�ng Dv,��` 0 MEGAN DAOUST L I V E B E A U T I F U L L Y DRAWING TITLE: CAYTON RESIDENCE PROJECT ADDRESS: 11301 W. 40TH AVE. WHEATRIDGE, CO DRAWING TITLE: MAIN LEVEL ELECTRICAL PLAN SCALE: 1/4" = 1'-0" D RAW N BY: M DAOUST DATE: 1/12/2020 REVISIONS: NOTES: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF MEGAN DAOUST INTERIORS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH MEGAN DAOUST INTERIORS. WRITTEN DIMENSIONS SHALL NOT TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOBSITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF MEGAN DAOUST INTERIORS PRIOR TO THE COMMENCEMENT OF ANY WORK. 0rel E1,61 City of Wheat idge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Plumbing Subcontractor This form must be completed & signed by the PLUMBING SUBCONTRACTOR performing plumbing work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 11301 W 40th Ave WheatRidge CO 80214 General Contractor: REGAL CONSTRUCTION INC. FORM WILL NOT BE ACCEPTED WITH MISSING INFORMATION Company Name: GOOD PLUMBING SVCS Contact Phone #: 303-455-8639 Wheat Ridge Contractor License #: 7I 7K (required field) State License #: OCYM XS'3 i Master License #: Date dge- Ac-7,z City of Wheat 1 CNA, UITYVFf,0 ffMFNS F SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 11301 W 40th Ave WheatRidge CO 80214 General Contractor: REGAL CONSTRUCTION INC. "CORM WILL NOT BE ACCEPTED WIT14 MIfISCING INFORMATION Company Name: CREATIVE ELECTRIC Contact Phone #: 303-781-1241 Wheat Ridge Contractor License #: 0 Ci k (required field) State License #: Master License #: Date r/ From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Addition to Existing Building Date: Friday, April 16, 2021 1:56:16 PM Addition to Existing Building THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this Residential or Residential - upload Proof of Submission to Sanitation District Commercial? and Water District Upload Proof of WESTRIDGE SANITATION PROOF OF SUBMISSION.Ddf Submission to Sanitation Department Upload Proof of CONSOLIDATED WATER PROOF OF SUBMISSION Ddf Submission to Water Department PROPERTY INFORMATION Property Address 11301 W 40th Ave Property Owner Name Schuyler Cayton Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 719-651-5242 scayton@wmacolorado.com APPLICANT INFORMATION Applicant Name Regal Construction Inc. What is your role in the project? General Contractor Wheat Ridge 110221 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contact Phone Number 303-903-1790 (enter WITH dashes, eg 303-123-4567) Contact Email Address for Plan Review Comments regalconstruction@comcast.net Retype Contact Email regalconstruction@comcast.net Address DESCRIPTION OF WORK Detailed Scope of Work - Provide use of addition (i.e. master bedroom with master bathroom); Indicate mechanical, electrical, plumbing scopes Location of Work Square Footage of Addition Asbestos Report Engineering Letters, Energy Calcs and Other Letter Size Attachments Construction Plans scanned on 11 "x17" or larger Provide Passcode for Plans if locked Living Room Addition with crawlspace, extending existing HVAC and Electrical. Remodel existing kitchen, laundry and master bedroom suite. Addition to back of house 500 Cavton Project ASBESTOS TEST SUBMIT.odf 11301 W. 40TH AVE.-ILC.odf Site-Struct Plans 11301 W 40th Ave 4-13-2021 (2) SUBMITTAL ndf Field not completed. Project Value (contract 134,410.00 Valuation okay 5/10/21 KM value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Pete Regalado Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. tiff eurofins i EMLab P&K Report for: Jerry Harchek Turnstone Home Inspection Services 385 White Ash Dr Golden, CO 80403 Regarding Approved by: Project: 05-26-21 1 p; Drywall Samples EML ID: 2650461 Approved Signatory Amber Rutter Dates of Analysis: Asbestos PLM: 06-01-2021 \eSpbbottAsso . N CAA Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM -AS -S-1267) NVLAP Lab Code 500053-0 All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1 % asbestos concentration can be provided when requested. Eurofins EMI -ab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor. EurofinsEPKBuilt EnvironmentTesting, LLC EMI -ab ID: 2650461, Page 1 of Client: Turnstone Home Inspection Services C/O: Jerry Harchek Re: 05-26-21 1p; Drywall Samples ASBESTOS PLM REPORT Location: #1, Kitchen S wall near pantry Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Date of Receipt: 05-26-2021 Date of Report: 06-01-2021 Total Samples Submitted Total Samples Analyzed: 5 Total Samples with Layer Asbestos Content> 1%: 0 Lab ID -Version$: 12662638-1 Sample Layers Asbestos Content Gray Plaster ND White Skim Coat ND Multicolored Wallpaper ND Composite Non -Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Poor Location: #2, Mstr bath S wall Lab ID -Version$: 12662639-1 Sample Layers Asbestos Content Gray Plaster ND White Skim Coat ND Multicolored Wallpaper ND Composite Non -Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Poor Location: #3, Hall bath behind door Lab ID -Version$: 12662640-1 Sample Layers Asbestos Content Gray Plaster ND White Skim Coat ND Multicolored Wallpaper ND Composite Non -Asbestos Content: 10% Cellulose Sample ComositeHomogeneity: Poor Location: #4, SE bdrm near entry Lab ID -Version$: 12662641-1 Sample Layers Asbestos Content Gray Plaster ND White Skim Coat ND Multicolored Wallpaper ND Composite Non -Asbestos Content: 10% Cellulose Sample ComositeHomogeneity: Poor The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC EMLab ID: 2650461, Page 2 of 3 Client: Turnstone Home Inspection Services C/O: Jerry Harchek Re: 05-26-21 1p; Drywall Samples ASBESTOS PLM REPORT Location: #5, Hall S wallnear SW bdrm Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Date of Receipt: 05-26-2021 Date of Report: 06-01-2021 Lab ID -Version$: 12662642-1 Sample Layers Asbestos Content Gray Plaster ND White Skim Coat ND Multicolored Wallpaper ND Composite Non -Asbestos Content: 10% Cellulose Sample ComositeHomogeneity: Poor The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". Eurofins EPK Built Environment Testing, LLC EMLab ID: 2650461, Page 3 of 3 RESIDENTIAL Address: 11301 W 40th Ave Lot Size: 34,594 (site plan) sq. ft. Property in the flood plain? No Subdivision: Brookside Related Cases: Rev. 09/2017 Permit- Plan Review Worksheet Zoning: A-1 Lot Width: 150 (ILC) ft. If yes, notify PW Floodplain Administrator and add surveying condition FLD Any conflict? (Y/N) Type of project (applicable survey conditions in parenthesis): Maximum Lot Coverage: 25 % 8,648.5 sq. ft. Existing Improvements (footprints): House: 2475 sq. ft. Shed: 80 sq. ft. Detached garage: sq ft. Other: sq. ft. Total Existing 2,555 Lot Coverage 7.4 Required Setbacks: FR 30' Provided Setbacks: FR 103.3' sq. ft S151 S S 29.4' S Proposed Improvements (footprints): House/addition: 3,249 sq. ft. Shed: 80 sq. ft Detached Garage: sq. ft. Other: sq. ft. Proposed+Existing 3329 sq. ft Lot Coverage 9.b % 15' R 15' 24.3' R 55.1' For additions or new construction, is the structure within 2 feet of minimum setbacks? No If yes, add surveying condition FND. Maximum Height: 35 ft. Proposed Height: 16.2 (tallest) fl Maximum Size: Proposed Size: sq. ft. sq. ft. Does the bulk plane apply? (Y/N) NO If yes, does it meet on all sides (Y/N): FR S S R (See 26-642 and 26-120.C.1 -applies to all single-family structures (new, addition, accessory) in R-1 C and R-3) Parkland Conditions Does the permit result in a new dwelling unit (new structure or conversion from non -res use)? No If yes, have parkland dedication fees already been paid (eg with a previous land use approval)? If fees are owed, add condition PFEE, notify owner, notify building division, enter fee amount in ADG. Rev. 09/2017 Streetscape Conditions Does the permit result in any of the following conditions? ❑ Construction of new roads ❑ Platting of new lots ❑ New development ❑ Additions that increase gross floor area (not just the footprint) by 60% or more (proposed floor area — existing floor area ) / existing floor area = °% increase If any box above is checked... For SF/DUPLEX-Is there existing ❑ Curb ❑ Gutter L]5 -ft+ sidewalk adjacent to the property? If curb, gutter or sidewalk is missing, streetscape construction or fees -in -lieu will be required. MULTIFAMILY Does the frontage meet current city standards? If not, streetscape construction or fees -in -lieu will be required. Fees -in -lieu of dedication or construction are due at the time the permit is issued. Access Conditions (apply to all new driveways, garages, additions, or new homes/units) ❑ For one and two-family dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. ❑ For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer than 25' to any property line, except when used as joint access for two or more lots. ❑ In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. ❑ One and two-family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. ❑ For all uses, one access point per property is permitted. Existing gravel horseshoe driveway on A-1 property Landscaping Conditions (apply to additions and new dwelling units) ® For one -and two-family dwellings, one tree for every 70 feet of street frontage is required. Frontage of lot 160.4 - width of driveway 34� / 70 = 2 (round up for required trees) Street trees required: 2 Street trees provided: 4 Ll 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance of C.O. ® In the event that landscaping cannot be installed due to inclement weather prior to the issuance of a C.O., an escrow agreement with financial guarantees may be allowed to ensure future installation. 125% of the cost of the proposed improvements will be required with the agreement. These funds will be reimbursed back to the property owner or contractor once the improvements are in place. Dwelling Unit ❑ Not approved as an independent dwelling unit. N O N t- it r 0 0 U LL N N L, 0 Know what's below. Call before you dig. Fire Blocking and Draft Stopping shall be installed in concealed spaces per R302.11 & R302.12. Bathroom lighting shall comply with code section R303.3 and bathroom ventilation shall comply with code section R303.4. Minimum Ceiling height shall be 7' or accordance with section R305.1.1. Bathroom fixtures shall have proper clearances and spacing per code section R307 & P2705.1. Safety Glazing: glazing adjacent to doors per R308.4.2, glazing in windows per R308.4.3, glazing at wet surfaces per R308.4.5 and glazing adjacent to the bottom of the stairs per R308.4.7. Smoke Alarms shall comply with R314. Carbon Monoxide Alarms shall comply with R315. Hot water pipe insulation shall comply with code section N1103.4.2. Domestic cooking exhaust equipment shall comply with code section M1503.1. Decorative gas fireplace shall comply with code sections 2432.1 — 2432.3 or 2434.1-2434.2 depending on the application. Please provide the inspector the installation instructions at time of inspection. �..,, coy of 'Y',I�''� 1r�k�'1Lete r.,.un Nir' Ltl�'t lnrytt rvt APPROVED kirkmoney 05/10/2021 Plans Eaamfnw Date MWAmilL JM. �-pls/n,"ta �•r'�'Ie. p.d..d,. d �•l"w^.P .�..v-+t e..r.ae _�._.o.,. w.am r­�-v tpv.,b+...R.. a.. lx�.u.n...-a.r,......t,.� mft w J"*F'ePplaarn WMr MY fft* l W60" Underfloor area shall comply with code section R408 Reviewed for Zoning Compliance by the City of Wheat Ridge Planning Division APPROVED BY: � DATE: April 30, 2021 COMMENTS: Approved with conditions Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. In addition, no less than twenty-five percent (25%) of the gross lot area and no less than one hundred percent (100%) of the front yard shall be landscaped. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development Code. All landscaping shall be installed in accordance with the approved landscape plan prior to issuance of a C.O. If landscaping cannot be installed prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 125% of the cost of the installation shall be required. R15 CRAWL SPACE WITH 6 MIL VAPOR BARRIER NOTE: PRESCRIPTIVE ENERGY APPROACH 1. CRAWL SPACE TO BE CONDITION WITH HOME HVAC 2. NEW CONDITIONED AREA = 577 SQ FT PROVIDE L/150 ATTIC VENTILATION = 3.85 SQ FT (50% SOFFIT -50% ROOF TOP NEAR HIGH POINT) PER ELEVATIONS ROOFING SHEATHING AND FRAMING PER STRUCTURAL R49 INSULATION INSULATION BAFFLE AT SOFFIT VENT DRIP EDGE VENTILATION R20 WALL INSULATION, MIN PER STRUCTURAL WINDOW PER FLOOR PLAN U=0.32 OR BETTER 1/2' DRYWALL AT INTERIOR WALLS AND CEILINGS FLOOR SHEATHING AND FRAMING PER STRUCTURAL <— U-0.30 or Better _ FIRST FLOOR FINISH GRADE PROVIDE MIN. 10% SLOPE IN FIRST 5'-0' AROUND ALL FOUNDATIONS CONCRETE FOUNDATION PER STRUCTURAL FOUNDATION DRAIN AND DAMPROOFING TYPICAL SECTION SCALE: 1/2"=V-10" 150.0' +__ I I � I I � I I � I I � I I � I I � I I � I I _+ 3 13 13 I 00 LO I I LO '00 CID I I �'•^ NEW 1 STORY go*= ADDITION PATIO ITNOINI. FF=100.0' �� aao r z t24'-3 3/4"123 J - EXISTING 1 STORY- SINGLE FAMILY t29'-4 5/8" RESIDENCE M FF=100.0' DRI AY. • I _(3) I� Co N I GRAVEL /. DIRNEW4Y ut - I 0011+ 0100 000 0000 �\ 000 Vol'i .100 q �j► �o�,l •�:�•, �� +00 Cyd �. SITE PLAN 1 SCALE 1" = 20'-0" PROJECT SUMMARY: NEW 1 STORY ADDITION TO A SINGLE FAMILY RESIDENCE OVER CRAWL SPACE SITE DESCRIPTION: ADDRESS: 11301 W. 40TH AVENUE WHEAT RIDGE, CO 80033 LEGAL DESCRIPTION: PART OF TRACT 5 BROOKSIDE SUBDIVISION COUNTY OF JEFFERSON STATE OF COLORADO CONTACT INFORMATION: [O ►Tl T11211:10 DESIGN/ENGINEER: JOHN J. STENSGAARD, PE S2E STRUCTURAL ENGINEERS 5552 E. 117TH CIRCLE THORNTON, CO 80233 (303) 252-0471 JOHNOS2E.COM SITE STATISTICS: ZONING: A-1 AGRICULTURAL AREA: LOT SIZE _ HOUSE SIZE _ FIRST FLOOR GARAGE COVERED PORCH SHED ADDITION COVERED PATIO ADDITION TOTAL BUILDING COVERAGE = ALLOWABLE BUILDING COVERAGE = NEW BUILDING HEIGHT = ALLOWABLE BUIDLING HEIGHT = 34,594 SQUARE FEET 1,896 SQUARE FEET 543 SQUARE FEET 30 SQUARE FEET 90 SQUARE FEET 577 SQUARE FEET 173 SQUARE FEET 3,309 SQUARE FEET (9.6% OF LOT) 8,649 SQUARE FEET (25% OF LOT) 16.5 FEET 35.0 FEET CL O ? W LU ao C�lU Z LU "' C%4 N C/) Z W W W LO P Ul � M F i CV v 300 W -s-O H �U UW 19 04 i a L0 0 Lo Z O a M M > o O °0 Z W 0 WWo > g Z Q0 MJo0 W �> M Z 0 z a V ISSUE HISTORY 1 PERMIT 3-29-2021 SHEET TITLE SITE PLAN & TYPICAL WALL SECTION DRAWN AK CHECKED JJs DATE 3/29/2021 JOB NO. 2021-41 SHEET C1.1 N O N F- S U Of 13- 0 U LL N N S O TOP OF PLAT 10'-1 1/8" BACK ELEVATION NORTH I SCALE: 1/4"=1'-0" FINISH GRADE FINISH GRADE LEFT ELEVATION WEST I SCALE: 1/4"=1'-0" RIGHT ELEVATION EAST I SCALE: 1/4"=1'-0" FINISH GRADE T SHINGLES D# FELT IP OF PLATE )BOARD FASCIA CL 0 O x U) W 0 0 z W z Z W Lu W F u Q Z O a M > O °0 Z WO Wz� Z Q0 Jo0 m� Ld a �o M ryo Z W O = � a a V ISSUE HISTORY 1 PERMIT 3-29-2021 SHEET TITLE EXTERIOR ELEVATIONS DRAWN AK CHECKED JJs DATE 3/29/2021 JOB NO. 2021-41 SHEET A5.1 N O N x r 13- 0 0 LL N N L, 0 108 18'-0" 6 X 6 WOOD POST - TYPICAL 2 PLACES rr I 11 _II 107 28'-11 1/2" 103 11 I I I I I I I I I I I I I I I I I I I IIS 11111111111111111111111 I II I I I I I I I I I I I I I I I I I I I 11� 11 IIIIIIIIIIIIIIIII 1. III I I I I I I I I I I I I I I I I I I I 11� Illllllllllllllllllllll� I II I I I I I I I I I I I I I I I I I I I 11� �Illllllllllllllllllllll III I I I I I I I I I I I I I I I I I I I II NEW 2 X 10 WOOD JOIST INFILL AT 16" O.C.--� I� II II - J� FIRST FLOOR FRAMING: 3/4" T&G PLYWOOD FLOOR SHEATHING PER GENERAL STRUCTURAL NOTES OVER 11 7/8" TJ1360 PLYWOOD WEB JOISTS AT 16" O.C.. UNLESS NOTED CONCRETE FOOTINGS: 8" THICK X V-6" WIDE CONTINUOUS CONCRETE FOOTING WITH 2 #4 CONTINUOUS, TYPICAL I I I Irjarm__ I I I I I I I I I I I I 107 I !'j FLOAT 1 1 1 1 1 1 1 1 1 1ALS PER 1 J105 1 P \ DETAIL 1,09, TYPICAL I I I I I I I I I I II I tl L1_L1—L1—L1-1-1_I 1_I_1J Al lip IIS IN / \ Dwelling garage o ® o L 1104 separation shall comply with code IIN section R302.6 fill �j ' 1 L n al /1L U_/// F al i I I I II II � II II � II II I I II II I I II II ISI II N 1 j I I LL__-- —J L— --- __P pl I II� Ila I� II II II I� I 1 I 1 lip FOUNDATION/FIRST FLOOR FRAMING PLAN SCALE: 1/4"=1'-O" LEGEND — — — — — ROOF LINE, RIDGE, HIP, VALLEY, OVERHANG BEAM AS NOTED (S) INDICATES SLOPED (D) INDICATES DROPPED - BELOW FRAMING PREFAB WOOD TRUSS PER SCHEDULE EXISTING WALLS — - - — JOIST FRAMING AS NOTED NEW BEARING WALL BELOW ARCHITECTURAL NON-BEARING WALL, CONCRETE WALL, SEE DETAILS 2 X 6 WOOD STUD EXTERIOR WALLS AT 16" O.C. ROOF OVER FRAMING STEP FOUNDATION WALL STEP, SEE ARCH'L T.O.W. ELEVATIONS FOR HEIGHT FRAMING NOTES: 1. PROVIDE COMPLETE STUD FILL UNDER BEAM AND GIRDER TRUSS BEARING, MIN. (4) 2 X 6 STUDS AT BEARING. I 2. CONTRACTOR TO COORDINATE FRAMING FIRST FLOOR FRAMING: LJ L L 16d AT 12" III MULTIPLE MICROLAM LVL BEAMS, EACH MICROLAM. FLOO SHEATHING BEAM TO BEAM CONNECTIONS; I I PER G NERALYSTRUCTURAL NOTES W .. .. -1 .. LO OVER 2 X 6 WOOD JOISTS BEARING ON TREATED PLATES ATTACHED TO ul �M F i 04 v U00 CONCRETE SLAB lip IIS IN / \ Dwelling garage o ® o L 1104 separation shall comply with code IIN section R302.6 fill �j ' 1 L n al /1L U_/// F al i I I I II II � II II � II II I I II II I I II II ISI II N 1 j I I LL__-- —J L— --- __P pl I II� Ila I� II II II I� I 1 I 1 lip FOUNDATION/FIRST FLOOR FRAMING PLAN SCALE: 1/4"=1'-O" LEGEND — — — — — ROOF LINE, RIDGE, HIP, VALLEY, OVERHANG BEAM AS NOTED (S) INDICATES SLOPED (D) INDICATES DROPPED - BELOW FRAMING PREFAB WOOD TRUSS PER SCHEDULE EXISTING WALLS — - - — JOIST FRAMING AS NOTED NEW BEARING WALL BELOW ARCHITECTURAL NON-BEARING WALL, CONCRETE WALL, SEE DETAILS 2 X 6 WOOD STUD EXTERIOR WALLS AT 16" O.C. ROOF OVER FRAMING STEP FOUNDATION WALL STEP, SEE ARCH'L T.O.W. ELEVATIONS FOR HEIGHT FRAMING NOTES: 1. PROVIDE COMPLETE STUD FILL UNDER BEAM AND GIRDER TRUSS BEARING, MIN. (4) 2 X 6 STUDS AT BEARING. 2. CONTRACTOR TO COORDINATE FRAMING LAYOUT WITH PLUMBING, VERIFY W/ ARCH'L 19 3. PROVIDE CONSTRUCTION ADHESIVE AND 16d AT 12" O.C. TOP AND BOTTOM STAGGERED CONNECTION OF MULTIPLE MICROLAM LVL BEAMS, EACH MICROLAM. 4. PROVIDE THE FOLLOWING HANGERS AT BEAM TO BEAM CONNECTIONS; (2) 9 1/2" MICROLAM LVL HUS410 (2) 11 7/8" MICROLAM LVL HU412 (3) 11 7/8" MICROLAM LVL HU612 3 1/2" X 11 7/8" PARALLAM HU412 (2) 14" MICROLAM LVL HU416 (3) 14" MICROLAM LVL HU616 (2) 14" MICROLAM LVL HU416 6 X 12 OR 6 X 10 WOOD BEAM HUC61 (ALL HANGERS TO BE SIMPSON STRONG -TIE) COORDINATE ALL DIMENSIONS WITH ARCH'L RESOLVE DISCREPANCIES PRIOR TO FABRICATION AND CONSTRUCTION z O a M M > o O 00 Z W0 WWo Z Q 0 Jo0 >W Q > 0 M Z O z � a a ISSUE HISTORY 1 PERMIT 3-29-2021 HEET TITLE =OUNDATION/ -IRST FLOOR =RAMING PLAN RAWN AK HECKED JJs DATE 3/29/2021 JOB NO. 2021-41 HEET S1.1 V O Z 19 W Lu ao U C�j Z "'N C,) � Z W W W LO P ul �M F i 04 v U00 W -S-O H �0 uWO 19N i a L0Lo I - z O a M M > o O 00 Z W0 WWo Z Q 0 Jo0 >W Q > 0 M Z O z � a a ISSUE HISTORY 1 PERMIT 3-29-2021 HEET TITLE =OUNDATION/ -IRST FLOOR =RAMING PLAN RAWN AK HECKED JJs DATE 3/29/2021 JOB NO. 2021-41 HEET S1.1 N O N x Of 13- 0 0 LL N N Ll 0 6 0 I 308 `" / " MICROLAM OUI (3)B 1M Z304 0 T - F_ I 28'-11 1/2" ROOF FRAMING: 1/2" PLYWOOD ROOF SHEATHING PER GENERAL STRUCTURAL NOTES OVER PREFAB WOOD TRUSSES BY 305 HEADER IN WOOD STUD WALL PER I TRUSS MFR,UNLESS NOTED DETAIL 302, TYP ---- -------i------- Y3005 ----------- --- ---- ------- -------- --- - --� --- -------- - ------ -- -- a Ir- II L-J-----=-----J--J LL_ II I II II I I II I __ __ __ __ II _ 1 z 1 1 I I I Q 304 'O �_ __ __ I __ __+__ __ __ -- _II 1 1 o I I- -- -- II I I LLL _._._....... ...... _.l._._._._._._._._._.J ROOF FRAMING PLAN SCALE: 1/4"=l' -O" LEGEND — — — — — ROOF LINE, RIDGE, HIP, VALLEY, OVERHANG BEAM AS NOTED (S) INDICATES SLOPED (D) INDICATES DROPPED — BELOW FRAMING PREFAB WOOD TRUSS PER SCHEDULE EXISTING WALLS — — — JOIST FRAMING AS NOTED ============= NEW BEARING WALL BELOW STEP T. 0. W. ARCHITECTURAL NON—BEARING WALL, CONCRETE WALL, SEE DETAILS 2 X 6 WOOD STUD EXTERIOR WALLS AT 16" O.C. ROOF OVER FRAMING FOUNDATION WALL STEP, SEE ARCH'L ELEVATIONS FOR HEIGHT FRAMING NOTES: 1. PROVIDE COMPLETE STUD FILL UNDER BEAM AND GIRDER TRUSS BEARING, MIN. (4) 2 X 6 STUDS AT BEARING. 2. CONTRACTOR TO COORDINATE FRAMING LAYOUT WITH PLUMBING, VERIFY W/ ARCH'L 3. PROVIDE CONSTRUCTION ADHESIVE AND 16d AT 12" O.C. TOP AND BOTTOM STAGGERED CONNECTION OF MULTIPLE MICROLAM LVL BEAMS, EACH MICROLAM. 4. PROVIDE THE FOLLOWING HANGERS AT BEAM TO BEAM CONNECTIONS; BEAM SIZE: HANGER TYPE: (2) 9 1/2" MICROLAM LVL HUS410 (2) 11 7/8" MICROLAM LVL HU412 (3) 11 7/8" MICROLAM LVL HU612 3 1/2" X 11 7/8" PARALLAM HU412 (2) 14" MICROLAM LVL HU416 (3) 14" MICROLAM LVL HU616 (2) 14" MICROLAM LVL HU416 6 X 12 OR 6 X 10 WOOD BEAM HUC61 (ALL HANGERS TO BE SIMPSON STRONG—TIE) COORDINATE ALL DIMENSIONS WITH ARCH'L RESOLVE DISCREPANCIES PRIOR TO FABRICATION AND CONSTRUCTION CL 0 O 12 42 x U) W 0 ru Z W o0 ZLoN N � MC/) cno z W �M F i CV W U 000 O H �0 V_ s; U W O 19N IS - 09 � I�- Z O a M M O O °0 Z W 0 Wz� Z Q 0 MJo0 W �> Q cl M Z O z � a a ISSUE HISTORY 1 PERMIT 3-29-2021 SHEET TITLE ROOF FRAMING PLAN DRAWN AK CHECKED JJs DATE 3/29/2021 JOB NO. 2021-41 SHEET S1.2 N O N F S U' Of >- 13- 0 D_0 U 0 I 107 NO SCALE 2 #5 X 24" LONG, TOP AND BOTTOM DRILL AND EPDXY 4" DEEP HOLE WITH HILT] HIT EPDXY SYSTEM (CONTRACTORS OPTION: SIMPSON ET EPDXY TIE) NEW CONCRETE FOOTING AND STEM WALL 108 NO �ICAL 109 NO SCALE 601-01 POST ON ABU66 POST BASE IED GRADE OR CONCRETE SLAB E OCCURS I X 42" BELOW GRADE CONCRETE WITH 2 # 5 VERTICALS 2003-058 HOOD STUD WALL 30d NAIL PROVIDE LOOSE SUP HOLE IN TOP BASE PLATE, AND PREDRILL SNUG -IOLE IN BOTTOM BASE PLATE age dwelling unit )ration per 2.6 POWDER DRIVEN FASTNERS AT 24" O.C. SHIM TO SUPPORT BASE MATERIAL CONCRETE SLAB 101-01 104 NO SCALE PLYWOOD SHEATHING PLYWOOD WEB JOIST 105 N IOD FLOOR AND WALL FRAMING X 6 CONTINUOUS PRESSURE TREATED IOD PLATE WITH 1/2" DIA. X 10" NG ANCHOR BOLTS AT 48" O.C. #5 CONTINUOUS ISHED GRADE OR CONCRETE SLAB OCCURS ,NCRETE STEM WALL SEE DETAIL 103 ,NCRETE FOOTING � II II EXISTING WOOD STUD WALL M II EXISTING FLOOR FRAMING M Ap= a a1Tama 1I IVI III IN I I I I I I I I I I I I I i f I SIMPSON THA TYPE HANGER 1060 NO SCALE 101-01 601-01 IIN CONCRETE ENCASED ELECTRODE STEM WALL REINFORCING :RETE STEM WALL TIE TO FOOTING REINFORCING 1NG REINFORCING __..:RETE FOOTING NOTE: VERIFY LOCATION WITH ELECTRICAL PANEL SAWCUT — 1/8" WIDE X 1/4 SLAB THICKNESS IN DEPTH — CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE ACCOMPLISED WITHIN 24 HOURS OF CONCRETE PLACEMENT SAW CUT JOINT CONCRETE SLAB ON GRADE TOOLED JOINT 1 0 1 NO 'IISCALE TOOLED JOINT CONCRETE SLAB ON GRADE INTERSECTION CORNER 102 NSCALE NOTE: KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. "TOOL WET JOINT", "ZIP STRIP", ETC. SHALL MATCH SAWCUT REQUIREMENTS. 101-01 CORNER BARS SAME SIZE AND SPACING AS HORIZONTAL REINFORCING, 24" MIN. LAP CONCRETE STEM WALL OR FOOTING REINFORCING BARS PER PLANS AND/OR DETAILS CORNER BARS SAME SIZE AND SPACING AS HORIZONTAL REINFORCING, 24" MIN. LAP CONCRETE STEM WALL OR FOOTING REINFORCING BARS PER PLANS AND/OR DETAILS 103 L wort 601-01 NO SCALE 601-01 IOD STUD WALL YWOOD SHEATHING K 6 CONTINUOUS PRESSURE TREATED OD PLATE WITH 1/2" DIA. X 10" VG ANCHOR BOLTS AT 48" O.C. 15 CONTINUOUS ISIHED GRADE, SEE SOILS REPORT R ADDITIONAL REQUIREMENTS X 12 TREATED "WET SET" LEDGER TH (2) 1/2" X 5" LAG SCREWS AT I" O.C. NPSON IUT JOIST HANGER CONCRETE STEM WALL WITH #4 :RTICALS AT 32" O.C. TERNATE BENDS NCRETE FOOTING 101-01 Z O Q M M O 000 ZZ)0 LU z> Z QO Jo0 m 4,14- Ljj V M ' � Q Z O z G Q & t ' a �+ ISSUE HISTORY 7 PERMIT 3-29-2021 SHEET TITLE FOUNDATION DETAILS DRAWN AK CHECKED JJs DATE 3/29/2021 JOB NO. 2021-41 SHEET S2.1 O Z W o0 U Z �N N z W W 0 W LO P ' �M F i CV W U ado Q H �U � C U W O 1. N i Q L0 0 Lo Z O Q M M O 000 ZZ)0 LU z> Z QO Jo0 m 4,14- Ljj V M ' � Q Z O z G Q & t ' a �+ ISSUE HISTORY 7 PERMIT 3-29-2021 SHEET TITLE FOUNDATION DETAILS DRAWN AK CHECKED JJs DATE 3/29/2021 JOB NO. 2021-41 SHEET S2.1 EXISTING ROOF FRAMING EXISTING OR NEW 2 X 4 AT 4'-0" O.C. ROOF BRACE AT 45 DEGREE ANGLE, ATTACH WITH SIMPSON A35 ANCHOR BEAM EXISTING CEILING FRAMING, CUT AND HANG FROM BEAM WITH SIMPSON LUS HANGERS EXISTING BEARING WALL TO BE REMOVED I 307 YIVVU DCAM HI C/U31111V fRVVr mmmiIIV NO SCALE 2019-007 PLYWOOD ROOF SHEATHING PREFAB WOOD TRUSS 2X BLOCKING AT EVERY OTHER TRUSS SPACE, WITH 3 — 16d TOENAILS TO TOP PLATE WOOD BEAM SIMPSON H2.5 AT EACH TRUSS 02no) PREFAB WOOD TRUSS AT WOOD STUD WALL vvv I NO SCALE 304E NO SCALE ) ROOF SHEATHING WOOD TRUSS KING AT EVERY OTHER TRUSS MTH 3 — 16d TOENAILS TO TE 2X TOP PLATE H2.5 AT EACH TRUSS FUD WALL ) SHEATHING 601-01 YWOOD ROOF SHEATHING X 4 OUTRIGGERS AT 24" O.C. BLOCKING EFAB WOOD TRUSS J TOE NAIL AT 12" O.C. IUBLE 2X TOP PLATE )OD STUD WALL YWOOD SHEATHING ung) PREFAB WOOD TRUSS AT WOOD STUD WALL 601-01 \ v v vj NO SCALE 306 1 NO SCALE 601-01 3LYWOOD SHEATHING 2X WOOD OVER FRAMING XISTING ROOF TRUSS 3/4" PLYWOOD GUSSET, GLUE AND VAIL WITH 8d AT 4" O.C. EACH CHORD VEW SIMPSON THA HANGER EXISTING WALL TO BE REMOVED 601-01 301 CONNECTION HEADER SIZE NAILING JOIST TO ALL SILL OR GIRDER, TOE NAIL 3 — 8d BRIDGING TO JOIST, TOE NAIL EACH END 2 — 8d PLATE TO JOIST OR BLOCKING, FACE NAIL 16d 016" O.C. TOP PLATE TO STUD, END NAIL 2 — 16d STUD TO PLATE 4 — 8d TOE NAIL OR 2 — 16d END NAIL DOUBLED STUDS, FACE NAIL 16d ® 24" O.C. DOUBLED TOP PLATES, FACE NAIL 16d ® 16" O.C. TOP PLATE, LAPS AND INTERSECTIONS, FACE NAIL 2 — 16d CONTINUOUS HEADER, TWO PIECES 16d 0 16" O.C. ALONG EACH EDGE CEILING JOISTS TO PLATE, TOE NAIL 3 — 8d CONTINUOUS HEADER TO STUDS, TOE NAIL 4 — 8d CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL 3 —16d CEILING JOIST TO PARALLEL RAFTERS, FACE NAIL 3— 16d RAFTER TO PLATE, TOE NAIL 3 — 8d BUILT—UP CORNER STUDS 16d 0 24" O.C. NO SCALE ROUGH OPENING WIDTH ROUGH OPENING WIDTH HEADER SIZE UP TO 3'-0" 2-2X6 3'-0" TO 5'-0" 2 — 2 X 8 5'-0" TO 7'-0" 2 — 2 X 10 7'-0" TO 9'-0" 2 — 2 X 12 601-01 WOOD STUD WALL 16d AT 12" O.C. STAGGERED BOTH SIDES 2 — 16d AS SHOWN I I r_ 16d TOENAIL EACH BEARING STUD EACH SIDE I r, ---WOOD HEADER I 16d AT 12" O.C. FULL HEIGHT STUD, DOUBLE FOR OPENINGS 6'-0" AND GREATER BEARING STUD, DOUBLE FOR OPENINGS 5'-0" OR GREATER NOTE: THIS SCHEDULE MAY BE USED ONLY WHERE NO OTHER HEADER HAS BEEN CALLED OUT ON THE PLANS 302 WOOD STUD WALL HEADER SCHEDULE NO SCALE 682-01 TOP SPLI W-0" MIN I AP 303 NCALE I PLATE .ICE 612-2101 IL O Z W 13W o0 Z � W N Nco O Z W W 0 W Lo I• i N v U� i/ W N i a Lo Z O Q co 0 O 00 Zw0 W z� Zao M0 W � V M ♦ ) ' � Q Z O = U W a ISSUE HISTORY 1 PERMIT 3-29-2021 'HEET TIME ROOF FRAMING DETAILS )RAWN AK :HECKED JJs )ATE 3/29/2021 IOB NO. 2021-41 MEET S2.2 GENERAL STRUCTURAL NOTES BUILDING CODE: 2018 EDITION OF THE INTERNATIONAL BUILDING CODE. 2018 EDITION OF THE INTERNATIONAL RESIDENTIAL CODE. LOADS: ROOF LIVE LOAD = 30 PSF (SNOW). ROOF DEAD LOAD = 15 PSF. FLOOR LIVE LOAD = 40 PSF. FLOOR DEAD LOAD = 15 PSF. STAIR LIVE LOAD = 100 PSF. WIND LOAD = 135 MPH ULTIMATE WIND SPEED, EXPOSURE C. SEISMIC DESIGN CATEGORY B. FOUNDATIONS: FOUNDATION DESIGN BASED ON NORMAL SOILS WITH NO SOILS INVESTIGATION. FOUNDATIONS TO BEAR ON SPREAD FOOTINGS TO MATCH EXISTING WITH THE FOLLOWING GIVEN GUIDELINES: MINIMUM DEPTH BELOW ADJACENT GRADE --------- 3'-0" MAXIMUM BEARING CAPACITY ----------------- 1,500 PSF LATERAL PRESSURE (ACTIVE) REQUIRED ---------- 35 PSF ADJACENT GRADE IS DEFINED AS ANY GRADE WITHIN 5-0" OF THE FOOTING LOCATION. MINOR MOVEMENT OF FOUNDATIONS CAN OCCUR DUE TO UNKNOWN CONDITIONS. OWNER ACCEPTS ANY RISK OF MOVEMENT. CONTRACTOR TO VERIFY EXISTING SPREAD FOOTING FOUNDATION. CONCRETE: MINIMUM 28 DAY STRENGTH 3,000 PSI EXCEPT AS FOLLOWS: FOUNDATION WALLS AND GRADE BEAMS ----------- 3,000 PSI SLABS ON GRADE ------------------------- 3,500 PSI FOUNDATIONS ---------------------------- 3,000 PSI MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND UNDER -FLOOR DUCTS, ETC. MAXIMUM SLUMP 4 1/2" FOR CONCRETE WITHOUT PLASTICIZER. IF PLASTICIZER IS USED, A HIGHER FINAL SLUMP MAY BE ALLOWED UPON STRUCTURAL ENGINEER'S APPROVAL. FLY ASH - SHALL BE LIMITED TO 18% OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. N:41N;1*jzl«]1►1c3 ASTM A615 (Fy = 60 KSI) DEFORMED BARS FOR ALL BARS. WELDED WIRE FABRIC PER ASTM A185, WIRE PER ASTM A82. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. CLEAR CONCRETE COVERAGES AS FOLLOWS: CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH EXPOSED TO EARTH OR WEATHER #6 OR LARGER ------------------------ #5 AND SMALLER ----------------------- ALL OTHER PER LATEST EDITION OF ACI 318. LAP SPLICES IN CONCRETE: ALL PLYWOOD SHALL BE C -D EXTERIOR SHEATHING, STRUCTURAL 2 OR BETTER WITH EXTERIOR GLUE AND SHALL BEAR THE STAMP OF AN APPROVED TESTING AGENCY. LAY UP PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. STAGGER JOINTS. ALL NAILING, COMMON NAILS. WHERE SCREWS ARE INDICATED FOR WOOD TO WOOD ATTACHMENTS, USE WOOD SCREWS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATIO AND SHALL BE ATTACHED AS FOLLOWS UNLESS NOTED OTHERWISE: USE THICKNESS SPAN/INDEX RATIO EDGE ATTACHMENT INTERMEDIATE ATTACHMENT ROOF 1/2" 32/16 8d ® 6" O.C. 8d ® 12" O.C. FLOOR 3/4" T&G 40/20 SCREWS ® 6" O.C. SCREWS ® 10" O.C. EXTERIOR WALL 7/16" 24/0 8d ® 6" O.C. 8d ® 12" O.C. SCREWS AT FLOOR SHEATHING SHALL BE #8 X 2 1/2" LONG FOR SHEATHING LESS THAN 1" THICK. ALL FLOOR SHEATHING SHALL BE GLUED TO JOISTS WITH AN APA AFG-01 QUALIFIED GLUE. ALTERNATE: OSB ALTERNATE TO PLYWOOD: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ENGINEER AND ROOFING CONTRACTOR. WHERE ROOF IS TO BE GUARANTEED, IT MAY NOT BE USED WITHOUT PRIOR APPROVAL FROM ROOF SYSTEM MANUFACTURER. RATED SHEATHING SHALL COMPLY WITH I.C.B.O. REPORT NO. NER-108, EXPOSURE 1, AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 1/32") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. DOUBLE UP FLOOR JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. DOUBLE UP STUDS AT JAMBS AND AS REQUIRED UNDER BEAMS IN BEARING WALLS. PROVIDE 2X SOLID BLOCKING AT MID -HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO TABLE 2304.9.1 OF THE INTERNATIONAL BUILDING CODE. WOOD CONNECTORS SHALL BE AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT AND EQUIVALENT ICC -ES APPROVAL. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS SHALL BE FLAGGED UPON HIS REVIEW. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DOCUMENTS SHALL ------ 3" BE CLOUDED BY MANUFACTURER OR FABRICATOR. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE ------ 2" CONSIDERED APPROVED AFTER ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. - 11/2" THE ENGINEER HAS THE RIGHT TO APPROVE OR DISAPPROVE ANY CHANGES TO CONTRACT DOCUMENTS AT ANYTIME BEFORE OR AFTER SHOP DRAWING REVIEW. LAP SPLICES, UNLESS NOTED OTHERWISE, SHALL BE CLASS "B" TENSION LAP SPLICES PER LATEST EDITION OF ACI 318. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. LAPS IN WELDED WIRE FABRIC SHALL BE MADE SO THAT THE OVERLAP, MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRIC SHEET, IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 INCHES. ALL REINFORCING BE CHAIRED TO ENSURE PROPER CLEARANCES. SUPPORT OF FOUNDATION REINFORCING MUST PROVIDE ISOLATION FROM MOISTURE/CORROSION ALL SPLICE LOCATIONS SUBJECT TO APPROVAL BY THE STRUCTURAL ENGINEER. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION WITH STANDARD 90 DEGREE HOOKS UNLESS NOTED OTHERWISE. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. CONCRETE COLUMN DOWEL EMBEDMENT SHALL BE A STANDARD COMPRESSION DOWEL WITH EMBEDMENT LENGTH ACCORDING TO THE LATEST EDITION OF THE ACI 318. ALL SHALL HAVE CURRENT ICC -ES APPROVAL. PREMANUFACTURED WIDISTS: DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC -ES REPORT ESR -1153. CONNECTIONS AND BEARING MATERIAL TO BE SHOP CONNECTED TO JOISTS AND DESIGNED AND FURNISHED BY JOIST FABRICATOR. PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS STATED IN THE GENERAL STRUCTURAL NOTES OR LOCATED ON PLANS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. CALCULATIONS AND SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC -ES APPROVAL. WOOD: SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION OR THE WEST COAST LUMBER INSPECTION BUREAU. ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY AND SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: THE SHOP DRAWINGS DO NOT REPLACE THE CONTRACT DOCUMENTS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER OR ARCHITECT ARE NOT TO BE CONSIDERED CHANGES TO CONTRACT DOCUMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAKE SURE ITEMS ARE CONSTRUCTED TO CONTRACT DOCUMENTS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. GENERAL: THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS). CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF COLORADO. Fb Fv E Fc WOOD O PSI PSI PSI PSI TYPE JOISTS: o0 zco W Z � w N 64 2 X 4 2 X 6 OR LARGER 675 (REP) 95 1,500,000 925 D.F. STND WW 1,450 REP 95 1,700,000 N A D.F. #2 BEAMS: V_ WIDTH 4" OR LESS F icV WC.) � WIDTH GREATER 1,500 (SING) 95 1,800,000 N/A D.F. #1 THAN 4" C ,Z V W N i 1,300 SING 85 1 1,600,000 N A I D.F. #1 LEDGERS AND TOP PLATES: 1,250 (SING) 95 1 1,700,000 N/A D.F. #2 STUDS: 2 X4 2 X 6 OR LARGER 675 (REP) 95 1,500,000 925 D.F. STND 1,450 (REP) 95 1,700,000 1,050 D.F. #2 POSTS: 4 X 4 4 X 6 OR LARGER 1,450 SING 95 1,700,000 1,000 D.F. 2 # 6 X 6 OR LARGER 1,250 SING 95 1,700,000 1,050 D.F. #2 1,200 SING 85 1,600,000 1,000 D.F. #1 THE SHOP DRAWINGS DO NOT REPLACE THE CONTRACT DOCUMENTS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER OR ARCHITECT ARE NOT TO BE CONSIDERED CHANGES TO CONTRACT DOCUMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAKE SURE ITEMS ARE CONSTRUCTED TO CONTRACT DOCUMENTS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. GENERAL: THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERETO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS). CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. ANY ENGINEERING DESIGN, PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF COLORADO. r� J co a V♦ 1 Z O a V LIJ D Z b �i T M r r co co C) 00 6 0 O U w LL Q w ISSUE HISTORY 1 PERMIT 3-29-2021 SHEET TITLE GENERAL STRUCTURAL NOTES rrn.�s CHECKED AK JJs DATE 3/29/2021 JOB NO. 2021-41 SHEET S2.3 O Z W C� o0 zco W Z � w N 64 a a O Z WW 0 W Lo V_ F icV WC.) � - H �0 C ,Z V W N i a Lo� r� J co a V♦ 1 Z O a V LIJ D Z b �i T M r r co co C) 00 6 0 O U w LL Q w ISSUE HISTORY 1 PERMIT 3-29-2021 SHEET TITLE GENERAL STRUCTURAL NOTES rrn.�s CHECKED AK JJs DATE 3/29/2021 JOB NO. 2021-41 SHEET S2.3 --i City of WheatRidge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Mechanical Subcontractor TMs form must be completed & signed by the MECHANICAL SUBCONTRACTOR performing mechanical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 11301 W 40th Ave WheatRidge CO 80214 General Contractor: REGAL CONSTRUCTION INC. Company Name: FOREMAN HEATING AND COOLING Contact Phone#: 303-667-5174 Wheat Ridge Contractor License #:_222300 (required field) David Ellard Printed Name of Authorized Agent T�¢vcc%(&44d 6/10/2021 Signature of Authorized Agent Date City 0f Wheatlkjoge CnY OF WIMAT RIDGE BUE.DmOAND INSPECTION SERVICES DIVISION 7500 W 29thAve WheatRid9e, C0 80033-8001 p.303.235.2855.f.303.237.8929 Proof of Submission for Permitting/Plan Review (Water and Sanitation only) A copy of this forth must be completed by each water and sanitation agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: 4/13/2021 Project Address: 11301 WEST 40TH AVENUE Name of FimVindividual submittingdocuments: REGAL CONSTRUCTION INC.% PETE REGALADO Project Type/Description: 600 SF ATTACHED SINGLE STORY LIVING ROOM ADDITION TO THE BACK OF HOUSE. Signature of Firm Representative orkndividual: DO NOT WRITE BELOW THIS POINT - FOR AGENCY USE ONLY I , am a duly authorized representative of the agency indicated below and do, by my signature below, hereby acknowledge receipt of documents necessary for review and approval of the project indicated above. Menu reorese(Please check one) o Wheat Ridge Water District o Consolidated Mutual Water District o Valley Water District o Denver Water Agency Notes: Signature: Date: (Agency Representative) o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District o Westridge Sanitation District o Other A) � � 01 �� 10 INSPECTION RECORD °ccunanc`;'Tyne INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Aauroval Of The Above Insnections Underground/Slab Inspections Date Inspector Initials Comments Electrical Comments Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof : f , Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Ally Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. For notification of your assigned inspection time window please email insptiiiierequestLd�ci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Time windows are assigned based on inspection routing. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Plumbing PERMIT - 201705937 PERMIT NO: 201705937 ISSUED: 08/11/2017 JOB ADDRESS: 11301 W 40th AVE EXPIRES: 08/11/2018 JOB DESCRIPTION: sewer service repair in yard only 30 ft, *** CONTACTS *** OWNER (303)421-3334 FISHER LEE E SUB (720)312-9102 Manuel Guerrero 120127 Pipeline Solutions *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 1,800.00 FEES Total Valuation 0.00 Use Tax 37.80 Permit Fee 70.70 ** TOTAL ** 108.50 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** City of Wheat Ridge Residential Plumbing PERMIT - 201705937 PERMIT NO: 201705937 ISSUED: JOB ADDRESS: 11301 W 40th AVE EXPIRES JOB DESCRIPTION: sewer service repair in yard only 30 ft, 08/11/2017 08/11/2018 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of O R or CONTRACTOR (Circle one) Date tiJ I, This permit wzrs issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, anew permit maybe required to be obtained. Issuance of anew permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any appR'�I- code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of /Wheat A,e MUNiTy DEVELOPMENT Building & Inspection Services Division C&AID 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929�� Inspection Line: 303-234-5933 Email: permits(cDci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # ab 17 Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): LP.P E,t/ Phone: �— Property Owner Email: N In Mailing Address: (if different than property address) Address City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: �� �� Fj� ,�S LLC. Contractors City License #: l Phone: Contractor E-mail Address: , Sub Contractors: Electrical W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL )] RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) 0 MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY DATE: OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of Wheat Ridge Residential Roofing PERMIT - 201701810 PERMIT NO: 201701810 ISSUED: 06/09/2017 JOB ADDRESS: 11301 W 40th AVE EXPIRES: 06/09/2018 JOB DESCRIPTION: Reroof Grand Sequoia; house only 4/12 pitch; 36 squares *** CONTACTS *** OWNER (303)421-3334 FISHER LEE E SUB (303)295-2220 Tomas Wofram 110052 Core Contractors, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2403 / APPLEWOOD VILLAGES, PROSPECT V BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,000.00 FEES Total Valuation 0.00 Use Tax 252.00 Permit Fee 236.00 ** TOTAL ** 488.00 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€lms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201701810 PERMIT NO: 201701810 ISSUED: 06/09/2017 JOB ADDRESS: 11301 W 40th AVE EXPIRES: 06/09/2018 JOB DESCRIPTION: Reroof Grand Sequoia; house only 4/12 pitch; 36 squares I, bymy signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicabble building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. r. Siggat �f 6WNER or CONTRACTOR (Circle one) Date 1. This � ermit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This. Permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made -be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and_procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Kimberlyl J 0 1 S /0 Cook `� I From: no-reply@ci.wheatridge.co.us Sent: Thursday, June 8, 2017 5:50 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Kim $ ti V() 0 Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those \ documents at the time you are issued your permit. Permits are currently being \ processed within 24-48 hours, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Existing permits that require amendments (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. PROPERTY INFORMATION Property Address 11301 w. 40th ave Property Owner Name Lee fisher wl Property Owner Phone 3034213334 CD Number Property Owner Email Field not completed. Address a Do you have a signed Yes _ contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Core Contractors 110052 3032952220 Contractor Email Address Docs@coredoes.com (permit pick-up instructions will be sent to this email) Is this application for a Yes new permit for a residential roof? Are you re -decking the No roof? Description of Roofing Gag grand sequoia Material How many squares of 36 material? Provide additional detail House 4:12 here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 12000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. 2 I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Will Fey Email not displaying correctly? View it in your browser. Agreement "Doing it right matters" CONTRACTORS ROOFING SYSTEMS Properly Owner Effective Date Lee Fisher 05/23/2017 Properly Address 11301 W 40th Ave City/State Zip _Wheatridge 80033 Primary Phone number Secondary Phone Number 303.421.3.334 Email Address lfisherwr(c�r comcast.net 4501 Logan St, Denver, CO 80216 303.997.1559 Terms: By signing this agreement, the Property Owner authorizes CORE CONTRACTORS, INC ("CORE") to perform the work and supply the materials as agreed upon by Property Owner's insurance carrier. Homeowner agrees to use CORE exclusively, and authorizes CORE to obtain labor and materials in accordance with the scope agreed to by the insurance company and ttie specifications set out in this Agreement to accomplish the replacement or repairs. The initial proposed scope of services is attached to this agreement. This agreement does not obligate the homeowner or CORE in any way, unless the damage is approved by homeowner's insurance carrier. Roofing Scope: The roofing system replacement includes all shingles, underlaynrent, valley Additional Roofing, Scope Notes linings and miscellaneous flashings, per local applicable municipal code. This Roof, shed roof and Gutters. also includes full clean-up of the property. A 5 year Roof Workmanship Warranty included on full roof replacement only. A one year workmanship warranty included all non -roof Due to the nature of repairs related to insurance claims, this contract includes an estimated repair price of the roof syslem, approximately S 20,929 Because the final scope hds not been agreed upon with the insurer, this repair price might change. The amount of this contract is for 100% of the replacement cost approved by the insurance company for work to be completed by CORE. Reaching agreement on the full scope of repairs involves considerable time on CORE's part; we will not proceed with that phase unless you agree to allow us to do the work once the scope is agreed upon. By signing this contract, you authorize CORE to reach agreement on the scope of repairs on your behalf. CORE agrees to bid the work using the primary insurance industry pricing database (Xactimate) based on the scope of work agreed upon with your insurer. You, the homeowner, recognize CORE CONTRACTORS, Inc. as a general contractor and as such shall be entitled to overhead and profit, at customary insurance industry rates (20% on Xactimate line items). Any substantial additions or deductions to the scope of work will be handled on the Customer Verification Form. Property Owner agrees that if a scope of work and project cost is agreed between CORE and the insurance carrier, that they are responsible to pay ONLY the deductible amount per their replacement cost insurance policy. Any further changes, in addition to the insurance work, must be requested in writing, by Property Owner. If, you, the Property O)wncr, plan to use the proceeds of a property and casualty insurance policy issued pursuant to Part 1 of Article 4 of Title 10, C.R.S. to pay for roofing work, pursuant to Section 6-22-105, C.R.S., THE ROOFING CONTRACTOR CANNOT PAY, WAIVE, REBATE OR PROMISE TO PAY, WAIVE OR REBATE ALL OR PART OF ANY INSURANCE DEDUCTIBLE APPLICABLE TO THE INSURANCE CLAIM FOR PAYMENT FOR ROOFING WORK ON THE COVERED RESIDENTIAL PROPERTY. PAYMENTS ARE TO BE MADE: '/2 (OR FIRST INSURANCE CHECK RECEIVED — ACV CHECK) UPON DELIVERY OF ROOFING MATERIALS. AND BALANCE UPON COMPLETION OF WORK. WORK TO BE COMPLETED WITHIN APPROXIMATELY 90 DAYS OF EXECUTED CUSTOMER VERIFICATION FORM. CORE SHALL HOLD IN TRUST ANY PAYMENT FROM THE PROPERTY OWNER UNTIL THE ROOFING CONTRACTOR HAS DELIVERED ROOFING MATERIALS AT THE RESIDENTIAL PROPERTY SITE OR HAS PERFORMED A MAJORITY OF THE ROOFING WORK ON THE RESIDENTIAL PROPERTY. Property Owner's Initials t Right to Cancel You, the homeowner, have the right to rescind this Agreement and obtain a full refund of any deposit within 72 hours atter entering the Agreement. If you plan to use the proceeds of a property and casualty insurance policy to pay for the roofing work, you may rescind this contract within 72 hours after you receive written notice from the insurer that your claim has been denied in whole or in part. Property Owner Date LF 05/23/2017 Property Owner Signature Insurance Company All State POWERED BY 4, canvas CORE CONTRACTORS, INC ("CORE") is authorized to provide you with this NOTICE. You are therefore notified that: (a) ANY PERSON OR COMPANY SUPPLYING LABOR OR MATERIALS FOR THIS IMPROVEMENT TO YOUR PROPERTY MAY FILE A LIEN AGAINST YOUR PROPERTY IF THAT PERSON OR COMPANY IS NOT PAID FOR THE CONTRIBUTIONS. 1. All contracts are subject to approval of our credit department and office without exception. The person executing this contract must obtain the approval from the officer of the CORE CONTRACTORS, INC. for this contract to be effective under any conditions. 2. SHOULD DEFAULT BE MADE IN PAYMENT OF THIS CONTRACT CHARGES SHALL BE ADDED FROM THE DATE THEREOF AT A RATE OF ONE AND ONE HALF (1 '/z) PERCENT PER MONTH (18% ANNUM) WITH A MINIMUM CHARGE OF $20.00 PER MONTH, AND IF PLACED IN THE HAND OF A COLLECTION AGENCY, ALL COLLECTION, LEGAL, AND FILING FEES SHALL BE PAID BY CUSTOMER ACCEPTING SAID CONTRACT. 3. CORE CONTRACTORS, INC. shall have no responsibility for damages from rain, fire, tornado, windstorm, or other perils, as is normally contemplated to be covered by home owners tisk insurance or business risk insurance, or unless a specified written agreement is made therefore prior to commencement of the work. 4. Should legal action be necessary because of any act that might arise during the course of this Agreement, CORE shall be entitled to all costs incurred in connection with such action, including a reasonable Attorney's fee. 5. The parties hereto agree that all actions or proceedings arising in connection with this Agreement shall be tried and litigated exclusively in the State and Federal courts located in the County of Denver, State of Colorado. 6. Replacement of deteriorated items (such as decking, fascia boards, roof jacks, ventilators, flashing or other materials) not covered by insurance, discovered during construction and required by governing code or necessary for product warranties are NOT INCLUDED and will be charged as an extra on a time and materials basis unless STATED IN THIS CONTRACT. 7. CORE CONTRACTORS, INC. shall not be liable for failure or performance due to labor controversies, strikes, fires, weather, and inability to obtain materials from usual sources, or any other circumstances beyond the control of CORE CONTRACTORS, INC. whether of a similar or dissimilar nature. 8. Subsequent to property owner's insurance cagier approval, if this agreement is terminated by the Owner, the Owner shall be financially responsible for all work performed based on the following milestones (percentages are additive). a. Consulting Phase: Preparation of CORE Xactimate scope of work and adjuster appointment — 31' o of total bid. b. Substantial agreement or scope confirmation with insurer— 5% of total bid. c. Ordering and scheduling of work — 2% of total bid. d. Repair Phase: Any line item of physical work that has been started shall be completed by CORE; if the owner terminates this agreement while physical work is ongoing, they shall be responsible for all costs related to that line item, phis general contractor overhead and profit. 9. In addition, the Owner shall be responsible for all other reasonable fees and expenses incurred prior to termination of the agreement, including permit fees, deposits paid by CORE to suppliers and subcontractors, subcontractor fees and expenses, etc. to the extent they are not already included in the line items for work that has been completed. All fees and expenses incurred prior to termination of this agreement shall be paid by the Owner within 30 days of invoice date. 10. If material has to be reordered or restocked because of a cancellation by the customer; customer will have to pay the restocking fee assessed to CORE by the supplier. 11. If any provision of this contract should be held to be invalid or unenforceable. the availability and enforceability of the remaining provisions of this contract shall not be affected thereby. 12. ANY REPRESENTATIONS, STATEMENTS, OR OTHER COMMUNICATIONS, NOT WRITTEN ON THIS CONTRACT ARE AGREED TO BE IMMATERIAL, and not relied on by either party, and do not sur,7ive the execution of this contract. 13. The maximum liability for CORE CONTRACTORS, INC. shall be the original cost of labor and materials for the repair which customer agrees shall be liquidated sum, under any event of default of CORE CONTRACTORS, INC. herein. 14. During the duration, of the work the customer's HOMEOWNER'S INSURANCE will be responsible for any interioz damage as long as CORE CONTRACTORS, INC. has taken appropriate action to protect the roof and siding during the repair of the roof and/or siding. 15. CORE CONTRACTORS, INC. is not responsible for existing construction problems of customer's home. If pointed out and notified to CORE CONTRACTORS, INC. we will try to assist you in correcting the existing construction problems on a time and material basis. 16. THIS CONTRACT IS COMPOSED OF THIS PAGE AND THE REVERSE SIDE OF THIS PAGE AND SHALL BE CONSIDERED THE ENTIRE CONTRACT BY THE PARTIES. POWEREC cY �c�invac i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 5u(A k 00 - -2,,00) Job Address: F Permit Number: S o 1 l o�5 1 ❑ No one available for inspection: Time I : Q5 Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: 1. Inspector: 1(, - DO NOT REMOVE THIS NOTICE 1* � I = CITY OF WHEAT RIDGE Y Building Inspection Division' (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax A INSPECTION NOTICE Inspection Type: 4 // / tf Job Address: _Yd L.J Permit Number: ❑ No one available for inspection_ Time/(-) 1.1-2- �W/PM Re -Inspection required: Yes L�od When corrections have been made, call for re -inspection at 303-234-5933 Date: i Inspector: DO NOT REMOVE THIS NOTICE f� t i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:'-� Job Address: 11 301 w q0 Permit Number: 4C/')01(5v 0 ❑ No one available for inspection:_Time ' ��4M/PM Re -Inspection required: YesC.No) When corrections have been made, call for re -inspection at 303-234-5933 Date:-, Inspectors' �l DO NOT REMOVE THIS NOTICE INSPECTION RECORD Occupancy /Type 'V LINE: (303) 234 -5933 INSPECTOR MUST SIGN ALL SPACES` PERTAINING TO THIS JOB " ✓ NSPECTIONS - ji DATE -' IN IITIALS COMMENTS: ons G)Concrete d Reinforcing or Monolithic " �.� :Weatherproof /:French Drain >. Sewer Service tines Water. Service lines INSPECTIONS FOR PLANNING S ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR: TO FINAL INSPECTIONS. POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB: FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ' DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED 4HS Rough Electric Rough; Plumbing Gas Piping Rough Mechanical ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING Framing Insulation Drywall :Screw FINALS'! .Electrical Plumbing Mechanical Roof " �.� Building; Final Fire Department R.O.W $r. Drainage INSPECTIONS FOR PLANNING S ZONING, FIRE AND PUBLIC WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR: TO FINAL INSPECTIONS. Parking & Land "NOTE: ALL ITEMS MUST BE COMPLETED. AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY :IS ISSUED.. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION '. 'OFA.CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Z i ' Job Address: /f SC Permit Number: ( f f L1 No one available for inspection: Time AM PM Re- inspection required: Yep No ' * When corrections have been made, call for re-inspection at 303 -234 -5933 Date: '✓ D Inspector: ? �i DO NOT REMOVE THIS NOTICE City of Wheat Ridge r 40001'r, Residential Roofing PERMIT - 101159' PERMIT NO: 101159 '. ISSUED: 05/07/2010 JOB ADDRESS: 11301 W 40TH AVE EXPIRES: 11/03/2010 DESCRIPTION: Reroof 35 sqs with 30 -y -yr dim.: shingles ' * ** CONTACTS * ** owner 303/421-3334 Dave Fisher sub 303/237-5179 Curt Marceau 02-2364 Roofing Plus ** .PARCEL INFO ** ZONE ''CODE: UA -USE: UA SUBDIVISION:' 0191 >BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED 'PROJECT VALUATION: !.8,800.00 FEES"' Permit Fee 217.50 CD 2� l Total Valuation . 00 44 _i.,- Use Tax 7158.40 ** TOTAL ** 375.90 Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2 requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering..:Midroof inspection is not required on permits purchased after 4/18./10. Contractor shall provide ladder for inspections.' Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re inspection !fee will be assessed. I hereby certify that the setback distances proposed by this permit application are accurate, and do: not violate applicable ordinances, rules or regulations of the City of :'Wheat Ridge or covenants, easements or restrictions: of record; that all measurements shown, and allegations made are accurate; that I have :read and agree to abide by all conditions printed on this application and that I assume full resp sibility for compliance with the Wheat'. Ridge Building Code (I.B.C) and all other e dl applicabl eatAie OrdinanAs for wPrk under this permit. Plans ?subject to field inspection. Signature of ief uilding Official :date INSPECTION REQUEST LINE: (303)234 -5933 rBUILDING OFFICE.: (303)235 - 2855''. REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR 'INSPECTION THE FOLLOWING BUSINESS DAY..' a e 4v City of W heat ldge COMMUNITY DEVELOPMENT - Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Date: Office: 303 - 235 - 2855 " Fax: 303- 237 -8929 Inspection Line: 303- 234 -5933 Building Permit Application Property Adtlress 11391 4/ - f-h 9 e Property Owner (please print): _ &Ile F %ShPf PhoneL�L"?) W . z� Mailing Address: (if different than property address) Address: City, State, Zip: 1 Confacto�`�: UX- �Yr✓l� � <l� Contractors City License X/ T Phone: Sub.Contr�ctots Electrical Plumbing: Mechanical: City License # City License # City License # D "e`scriutlor;t of_wortt ger�DVCfa�6�t bLt %�5 geJ1 /a��✓. Contract V�e� Review Fee (due at time of submittal): Squares BTU's Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I: have read and agree to abide by all conditions printed on this application and that i assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am . also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: // / (OWNER) (CONTRACTOR) er (AUTHORIZED REPRESENTATIV of (OWNER (CONTRACTOR) PRINT NAME: �'t/ e / i l e Tr SIGNATURE: 'fr //,� DATE:. DEPJRTMENT USE ON� ., s� Bldg Valuation: COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number Date 16262 9/24/2003 Property Owner. FISHER Property Address : 11301 W 40TH AVE Contractor License No. : 18083 Company : Sanders & Johnson Phone : 421.3334 Phone : 422 6606 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsi ilit co lianc ith t heat Ridge Building Code (U.6.C.) and all other applicable Wh ~ Ri~e r ce , for v- c under this perm~. (OWNER)(CONTRACTOR) SIGN Construction Value : $$,625.00 Permit Fee : $217.50 Plan Review Fee : $0.00 Use Tax: $103.50 ~ Total: $321.00 Use: Description : ADD A/C SYS7 EM IN ATTIC AREA BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval: Zoning : Approval: DM Approval : Occupancy: Walis OKAY PROVIDE SWITCHED LIGHT, GFCI OUTLET AND SERVICE PLATFORM AND WALK FROM ACCESS Roof : Stories : Residential Units : Electrical License No : 18121 Plumbing License No : Mechanical License No : Company;The Electri-Serve Corp. Company : Company : Expiration Date : 2/28/2005 Approval : DM Expiration Date : Expiration Date : Approval : Approval : (7) This permit was issued in acwrdance wilh the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within si#y (60) days from issue date or (B) ihe building authorizetl is suspended or abandoned for a period of 120 days. (3) If fhis permit expires, a new permit may 6e acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in ihe original plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done ihat wiil change the natural flow of water causing a drainage problem. (5) Contrador shall notify the euilding Inspector lwenry-four (24) hours in advance for ali inspeclions and shall receive wri¢en approval on inspection card before proceediingwit u essi softhejob. (6) The Issua a r pproval of drawings and specifcations shail not be construed to be a permit for, nor an approval of, any violation of lhe provisions o ildi c o ance, law, rule or regulation. ¢ Chief Building inspector Please sign Terms and Conditions on reverse side of page. - - - DEF'AR'CMENT UF PLANNING ANl) UEVELOPMENT Building Permit Number : 1c' Z. BUILDING INSPECTION DIVISION - 235-2855 ~z y6~ CITY OF WHEAT RIDGE Date 7500 WEST 297H AVENUE WHEAT RIDGE, CO 80215 Property Owner : c;~ t'4C4w Property Address 3 O/ 6iJ 5/B4qf-4r, Phone : yL/ -333f/ Contractor License No. Company : Phone :?r2Z- 6 606, OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMEN7 Construction Value : I hereby certity Ihat the eelback dislanees proposed bylhis permil applicatlon ere eceurele, ~ Peffl'tlt F@0 p and do not vlolate applicable ordlnances, rulas or regulalions ol tha Cily o1 V Jheat Rldga or 2~ ~ covenanle, easemente or reelrictlons ol reeord: lhal ell measuremenle shown. and allegellons made are accurale; lhal l have read and ayree Io ablde by all condltions rlnted on Ihis li e /ull res bllil tor eom Iia ti d Ihat 1 seu ns ith th h lldi l Rid B Use Tax : ~ 2D " on. an po i nce w ca a m e ea ga u ng app Code (U.B.C.) and all alher appllcebte Wheal d or , or under lhle permit. Z Total : (OWNER)(CONTRACTOR) SIGNED DATE ' Description 40--Il C.37bri) / BUILDING DEPARTMENT USE ONLY ME[= Approval : Zoning : WymbillEMORM Approvai : P,liplff~YVb71tStCDIIOmenC9; Appwval : Occupancy : Walls Root : Stories : Residential Unils : Eleclrical License No : Plumbing License No : Mechanical License No : Company : Company - Company : Expiration Date : Explration Oate : Expiration Date : Approval : Approval : Approval : J Ptdns RBqulrtid.:; ] ~ Pllhs Rdyutred .I :,A ! PlBns R0 uirtFdtH,, 11) thb permit wat is9ued In accordBn<e wilh Ihe provifion! Sel lorth In yopur eppliwllon And IS aubiect lo Ihe lawa ol Ihe Slata ol Cobrado enU lo Iha Zoning Requlalwns an0 Builtlinq Code ol W1+rn1 Pldqe, Cobredo or Tny othar epDlicable ordinancee ol lhe Clly. (2) th~e permd shali e.0ite d (n) Ihe work authonzed ie not wmmonced wtlhin eizty 180) deys Imm Issue dele or (B) Ihe bullding aulhonzetl ts euspended or abando,+ed br a Deriod ol 120 tlayf. (7) Il Ihie permn enpnes, e new Oermd may be ac7uhed br a lee of one-hnll lhe amounl normally reQU6ed, orovided no chnnges hzve been or will be mada in Ihe onginal olanf an0 e0euficalions end any suspenelon or abandonmenl hae not exceaded one (1) year. II chenges ere made or il suspeneion or abandonment exceeds one 11) yeac full leef shall be paitl For a nnw permit. (dI No work ot any manner shall 6e tlone thal will change the naWral Oow of waler causing e dralnage Dmblem. I51 Conlracbr ehall notrty Ihe BoilJing InSpec(or hvenly-loUr (24) M1ours m advancq br ell InspeCUOns end shall reterve wtllfen eppr rval on inspeClion Uitl Oefore prxeediing wdM1 successrve phases ol Ihe lob. f6) The issuance ol a permit or the approvat ol drawinge and specilicallona shall nol be construed lo be a permit lor, nor an approval of, any violalioo ol Ihe proviswns ol Ihe buitding codea or any other ordinance. law. rule or regulatlon. Chief Building Inspeclor For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY TI-IE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 NOURS PRIOR TO INSPECTION DEPARTPAENT OF COMMUNITY DEVELOPMENT ~n~~~' 7500 WEST 294h AVENUE 6UILDING INSPECTION DIVISION PERMIT N0. ~ 237-6944 EXT. 255 P.O. BoX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED 8Y THE CHIEF BUILDING INSPECTOR AND RECEIPTED BEIOW. JOB ADDRESS~07- E/5'7' aF CONTRACTOR M0 26A-iy 'E011-011V6 SYSTADDRESS t 4 4 O W. 3P--b A'l/c- CITY IkN O. ZIP CODE g a 2 z- 3 PHONE S3 E IICENSE NO. LLHIVCVUJ rl~nml i y s-zE-- 't./Fh-,~ T~ s r, ~ 2 OWNER ADDFESS 3 0 / 0✓ ~-f o ~ /kv . PHONE w,'1- 333`* ~ 1ZIPCODE b'0o33 GONTRACT PRICE $ 13 Z6, '-1- I TYPE Ground❑ 1 Woll❑ Proieefiny❑ Other SorOFaes SIGNS . . 2. MATERIAL II LUMINATION Yea❑ No❑ 3 Type Total Squara Feet Eleet Parmit No . . 4. SET BACK FROM PROPERTY LME N (Speeify which ia fronl) _ ❑ S_ E ❑ _ W ❑ ❑ . Zona_ . ApDrmed; 2ona Inspeefor OisopDroved I, TYPE Solido Mora Thon 80% Opan[] 2 MATERIAL Lses Than 80% Open Hsiqht FENCES 3. SET BACK FROM PROPERTY LINE N (Speeify whith iafront) _ ❑ S_ E ❑ _ W ❑ ❑ Zona_ Apprwed,Zons Impecta Disapproved 1 . ~l ^ OTHER Z,C ao~ DRAW SKETCH OR SFIOW BELOW,THE FENCE,SIGN,OR OTHEFZrSTRUCTURE, GIViNo DISTANCES FROIkPROPERTV LINES. (SETBACKS OR PROJECTIONS INCLUDEA) w ? ~ J f w O \ a ~ w ~ z J (VG Jr "l 7" l--O `.t~ ~ ~ SPECIFY NORTH STREET NAME W • 4 O~ A- V,t~ SHOW DISTANCES FROM THE MAIN BUILDING TOADJOINING HOUSES, STREETS, AND PROPERTY LINES; ON IRREGULAR tATS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICRTION FOR PLUPABING; ELECYRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PEfYMIY WILL EMPIRE 60 DAYS FROM DATE OF ISSUANCE !F WORK IS NOT STdRTED WITHl6d THAT TIME. ELECTRICAL PERMiT STATE IICENSE NO. ALUPRINUAAWIREUNDERSIZEOILLEGdL PLUMBING PERMIT STATE LICENSE N0. F100R BSM IST 2ND 3RD 4TH MECHANICAL PERMIT NQ FtEL:CirelsOneGap011ProponeCOOlEIecSolor Np, WATER CtASET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-CIRCUITS UTILITY(RANGE,DISPOSER,ETC.) FIXTURES WATER HEATER AUTO. WASHER DISH WASHER Refri eront Group Poundf Char e AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS 8i CONTROI.S FLDOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS 9 RECTFIERS. SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I NP TOTAL FIXTURES REMARKS ~;,X I L~ 5-+"0 2, A--G ~ 5!-F76- 17 /`"U 2 77F RL C" O I nerebyocknowledqe thot this avPlica- QERMIT FEE 3l `0v nd thaf I f d d ers a un tion is eonect on li- i i USE TAX " a app l th tonnot starf this projecf unt l with ll com I h d TOTAL FEE $ J l 51 y p s a . cation in apProve ~ ~ ihe lowa of Ihe Sta4e ol Colorado and to . }hs Zoninp Requlalions und Buildinq PROVE ' Code of the City of Wheat Ridqe. Any DI violafion ot the above 4erme will couse CHIEF BUIL INSPE 0 'ty Of hCOt idqe immediafe revocofion ot this permit. , Da9e Issued Z `9? ~ 40011CaM~ SiOnatun NO" 83E UNLESS ('R3~ CALL 237-8944 EXT. 255 24 HOURS IN ADVANCE FORINSPECTIONS 234 s~i33