Loading...
HomeMy WebLinkAbout13900 W. 43rd DriveX4r~ e L Safery, Industrial Hygiene ~ .;~^*si 5 T~.. & Environmental Health Consultants. September 10, 1994 Mr. Brian Coloroso High Plateau Truss 15595 Arapahoe Drive Golden, CO 80403 Dear Mr. Coloroso; On September 8, 1994, and September 9, 1994, MCA Environmental, Inc. conducted respirable dust sampling to determine personal exposures to employees at High Plateau Truss. Enclosed is the report for this industrial hygiene investigation. If you have any questions or need additional information please do not hesitate to contact me at 274-1211. .4 ! S4 c lY. P er D ppel Vice Pre i ent cc: Ms. Christina Barthel, Colorado Compensation Insurance Authority enclosurey 13~0~ 0-y3i2) Madison Plaza • S;iiT.e 200 • 90 Madison St. • Denver, CO 80206 • Phone (303) 399-123.3 - Fax (303) 399-1647 RESPIRABLE DIIST HYGIENE INVESTIGATION FOR: HIGH PLATEAII TRIISS 15595 ARAPAHOE DRIVE GOLDEN, COIARADO 80403 BY: MCA E:NVIRONNlENTAL, INC. 747 SHSRIDAN BLVD., IINIT 8B LAKEWOOD, COIARADO 80214 DIIST INDIISTRIAL HYGIENS INVESTIGATION During the week of August 29, 1994, MCA Environmental, Inc. was retained by Colorado Compensation Insurance Authority (CCIA) to conduct an industrial hygiene investigation at High Plateau Truss. The purpose of the investigation, as requested by Ms. Christina Barthel with CCIA, was to evaluate the employee exposure levels to respirable du:st. - High Plateau Truss is a manufacturer of wood trusses. One of the job activities conducted by the employees is cutting wood for the trusses. OBSffi2VATIONS AND RESIILTS On September 8, 1994 and September 9, 1994, Mr. Matt Roberts with MCA Environmental, Iiic. conducted an industrial hygiene inyestigation at- Eiiakr p'_ate3u .Truss o Mr. Roberts met with Mr. Brian Coloroso of High Plateau Truss and discussed the operations. Mr. Roberts observed that there were two band saws used for cutting wood for the.trusses. There was not a dust collection system for the band saw, however there was good qeneral ventilation. The cutting operations are conducted periodically through out the day with the majority of the cutting taking place in the morning. Approximately two hours of cutting is conducted during an eight hour shift and is conducted at brief periodic intervals. The type of wood used is primarily pine with some fir also used. On September 8, 1994, Mr. Roberts collected a respirable dust sample on Mr. Gary Weese between approximately 7:40 a.m. and 11:40 a.m. Mr. Weese was selected to wear the sample because he _ was the employee conducting the cutting and was anticipated to have the highest dust exposure. The air sample worn by Mr.. Weese was sample number A-HPT-001-001. On September 9, 1994, Mr. Roberts collected a respirable dust _ sample on Mr. Mike Duff between approximately 7:45 a.m. and 11:15=. a.m. Mr. Duff's job tasks involved building the trusses. Mr. I Duff was selected to wear the sample because it was determined that he would have the next highest dust exposure after the person conducting the cutting. The air sample worn by Mr. Duff was sample number A-HPT-001-002. Both samples were collected using a Gilian personal air sampling pump calibrated at 1.7 liters of air per minute through a 10 millimeter (mm) respirable dust cyclone onto a three piece PVC 37mm sampling cassette. Because typically the majority of the cutting is conducted in the mornings the samples were collected during the morning. The samples were submitted to Reservoirs Environmental Services laboratory in Denver, Colorado, for analysis. The result of sample A-HPT-001-001 was less than 0.22 milligrams of dust per cubic meter of air (mg/m3). The result of sample A-HPT-001-002 was less than 0.26 mg/m3). Refer to attached Reservoirs laboratory report. ^OD3dOMjISTQPI The Occupational Safety and Health Administration (oSHA) eight hour time weighted average for respirable dust is 5 mg/m3. The sampling by MCA was conducted over approximately a three and a half, and a four hour period during the highest anticipated dust exposure. Both of the respirable dust exposures measured by the two samples were below the detection limit of 0.22 and 0.26 mg/m3 and well below the OSHA eight hour time weighted average of 5 mg/m3. 2 ua/uaiaa ta:ca ~aua noa a186 RES. ENV. SERV. ~4 YCA RESERVOIRS ENVIRONMENTAL SERVICES, INC. AIHA Accreditation #480, PAT #10768 TABI.E 1. NUISANCE DUST PILTER ANALYSIS RESULTS RES Job Number: Client: Client Project: Date Samples Received: Matysis Type: Turnaround: RES 22028 MCA Emiranmental, lno. High Piatcau Truss-001 September 8. 1994 Nuisence Dust, Gravimetric 24 Hour Client Lab Air et Detection Air ID Number ID Numher Votume Weight Limit Concentretion Sampled (L1 (mg) (mg1m3) (mg/m3) A-HPT-001-007 EM 138302 447 BDL 0.22 BDL A-HPT-001-002 EM 738303 382 BDL 0.26 BDL rvu ~ rvone ueteciea BDL = Below Detection Limit NG = None Given NA s Not Anaiyzed Detection Limit = 0.1 mg U002/002