HomeMy WebLinkAbout2728 Fenton Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 4 3 6 Job Address: Permit Number: ❑ No one available for inspection: t'me - -� AM/PM Re -Inspection required: Yes (NO) When corrections have been made, call for re -inspection at 303-234-5933 Date: �/ / Inspector:% O NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Solar PERMIT - 201900096 PERMIT NO: 201900096 ISSUED: 02/01/2019 JOB ADDRESS: 2728 Fenton St EXPIRES: 02/01/2020 JOB DESCRIPTION: Install 4.88 KW roof mounted, flush mount, grid -tied solar pv system, 16 panels, no structural required *** CONTACTS *** OWNER (303)803-0572 KOCKLER DEREK T SUB (888)765-2489 Jared A Miller 110035 Tesla Energy *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,636.80 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I , by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be p d and tha all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Divis 6. The ; ss nce$or granf of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any ap lee e or a rdinance or regulation of this jurisdiction. rk is subject to field inspection. A w Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. I City of �(,j�_WheatR rLt-COMMUNITY DEVELOPENT /`{ �������✓'\ ge Building & Inspection Services 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(c)ci.wheatridge.co.us I FOR OFFICE USE ONLY Date: l I Plan/Permit # Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address:�� t �(� �Cn�T'�rJ T. L)1��AT (I�Oy(;, C� 8yi.l`( Property Owner (please print): MAN KouAL,C� Phone: '?) � - 3(y) US % L Property Owner Email: ��<u; We rO . (. c�c fj_% Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: Same as above City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor Name: Tesla Energy Operations Inc. City of Wheat Ridge License #: 110035 Contractor E-mail Address: Tylward@Tesla.com For Plan Review Questions & Comments (please print): Phone: Phone: (253)720-4461 CONTACT NAME (please print): Tyler Ward Phone: (253)720-4461 CONTACT EMAIL(p/ease print): Tylward@Tesla.com Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. ❑COMMERCIAL ❑✓ RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Install a 4.88 KW Roof -Mount, Flush-Mount,Grid-Tied Solar PV System Sq. FULF BTUs Gallons Amps Squares For Solar: � - M Kw 1 b # of Panels N 0 Requires structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ 6636.8 OW'NER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record, that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Jeremy Burks Digitally signed by Jeremy Burks 1/17/2019 Signature (first and last name): Date: 2019.01.17 07:39:00 -07'00' DATE: Printed Name: J(✓�'�E M i ' ,y�U DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDIt116 PARTMENT COMMENTS: Reviewer: 7 l PUBLIC WORKS COMMENTS: Reviewer: CONSTRUCTION TYPE: Building Division Valuation: January 15, 2019 RE: CERTIFICATION LETTER Project/Job # 80011912 Project Address: Kockler Residence 2728 Fenton St Wheat Ridge, CO 80214 AHJ Wheat Ridge SC Office Denver Design Criteria: Applicable Codes = 2012 IEBC/IBC, 2012 IRC, ASCE 7-10, and 2012 NDS Risk Category = II Wind Speed = 135 mph, Exposure Category C, Partially/Fully Enclosed Method Ground Snow Load = 30 psf - MP1: Roof DL = 8 psf, Roof LUSL = 21 psf (Non -PV), Roof LUSL = 17.91 psf (PV) MP3: Roof DL = 8 psf, Roof LUSL = 21 psf (Non -PV), Roof LUSL = 17.91 psf (PV) Version #74.1 - 1 Q x,40 LICE tn: X447 �- ice/ Q /2019::'i�' iAL STRUCTURAL ONLY" Abelardo De Vera a.. aolqowy1-7//r6 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22567 < 0.4g and Seismic Design Category (SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Sincerely Abe De Vera, PE, SE Structural Engineer Phone: 888.765.2489, x57526 Email: adevera@tesla.com 011 o% nepl gtid9® ;100 Tesla, Inc. T = 5 L t'i 3055 Clearwew `Nay San Mateo, CA 94402 p 650 638 1028 f 650 638 1029 Version #74.1 -1 HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware Hardware - Landscape Modules' Standoff Specifications X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MP1 64" 24" 39" NA Staggered 56.9% MP3 64" 24" 39" NA Staggered 56.9% Portrait Hardware Hardware - Portrait Modules' Standoff Specifications X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MP1 48" 20" 65" NA Staggered 71.1% MP3 48" 20" 65" NA Staggered 71.1% Mounting Plane Roof Pitch (Degrees) Qualification Results Member Evaluation Results MP1 19° Member Impact Check OK MP3 19° Member Impact Check OK Tesla, Inc. 3051 ear„ew ,bay San Mateo �A 94432 T E S L ri 'D28 f 95C 938 1029 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED THE ROOF ACCESS POINT REQUIRING A LADDER WHERE A UFER CANNOT BE VERIFIED OR IS NOT AC ALTERNATING CURRENT POWER-CONDITIONING INVERTER. SHALL NOT BE LOCATED OVER A WINDOW, DOOR PRESENT ONE SUPPLEMENTARY GROUND BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS, OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD ELECTRODE SHALL BE INSTALLED AND EMBEDDED A CONIC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING LABORATORY OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR MINIMUM OF 8 FEET INTO THE GROUND AND FITTED DC DIRECT CURRENT SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH SIGNS. IFC 605.11.3.1 WITH A LISTED CLAMPING DEVICE. EGC EQUIPMENT GROUNDING CONDUCTOR ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING AN OSHA APPROVED LADDER SHALL BE PROVIDED EXISTING ROOF AND PLUMBING VENTS SHALL NOT EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, AND SECURED TO THE STRUCTURE AT THE BE OBSTRUCTED BY ARRAY INSTALLATION. FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE APPROVED ROOF ACCESS POINT PER NOTE ABOVE PLUMBING VENTS ARE REQUIRED TO BE GALV GALVANIZED HAZARDS PER ART. 690.17. WITH AN OSHA APPROVED DEVICE DURING ALL RE-ROUTED THROUGH ATTIC SPACE AND GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE INSPECTIONS. TERMINATE A MINIMUM OF 6 INCHES ABOVE THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY ROOF LINE. VENTS SHALL TERMINATE TO THE OPEN HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. APPLICATIONS FOR A PHOTOVOLTAIC SYSTEM AIR. (2012 IPC SEC 904.3) I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY PROPOSING A PARTIAL OR COMPLETE RE-ROOF OF ImpCURRENT AT MAX POWER WITH ART. 250.97, 250.92(B).City kA THE EXISTING ROOF SHALL FIRST OBTAIN A Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING SEPARATE BUILDING PERMIT FOR SUCH WORK FROM ]�qrWheatP'99 Commum Mtor"04T` _•� kVA KILOVOLT AMPERE OR ARE RUN IN METALLIC RACEWAYS OR THE BUILDING DIVISION BY A LICENSED kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC CONTRACTOR AND SHALL PASS A FINAL APPROVED LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). INSPECTION PRIOR TO INSTALLATION OF THE MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN PHOTOVOLTAIC MOUNTING AND/OR RAIL SYSTEM. Reviewed for Code Compliance_ (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. DIRECT-CURRENT PHOTOVOLTAIC SOURCE AND NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE DIRECT-CURRENT OUTPUT CIRCUITS ON OR INSIDE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE A BUILDING SHALL BE CONTAINED IN A METAL ; 1— Date PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING RACEWAY. THE WIRING METHODS SHALL COMPLY POI POINT OF INTERCONNECTION HARDWARE. WITH THE ADDITIONAL INSTALLATION REQUIREMENTS�y�yiy pl�ermic Thr hswxl oJoO�•^'taopMo °�i�� PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE a � pr� soy he�� �aof*"C "pemit, � SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. OF NEC 690.31 (G)(1) THROUGH (4) S STAINLESS STEEL °""`""°`, qjw oWho� tG villa![ Of tOntt�MKO of Md �IgMFMW O STC STANDARD TESTING CONDITIONS :aaaa►oaK+aa�c�cesafr"eCay r�cer�+a vshanr�cer�+av TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VOLTAGE AT MAX V cP VOLTAGE AT OPENPOWER CIIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT " Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS l _ , 'y • Sheet 4 STRUCTURAL VIEWS Q Sheet 5 STRUCTURAL VIEWS LICENSE GENERAL NOTES Sheet 6 UPLIFT CALCULATIONS AND 2012 IRC. J �a Sheet 7 THREE LINE DIAGRAM TYPE EC # 8041 r �, A� 1. ALL WORK SHALL COMPLY WITH THE 2012 IBC �-•a `• Cutsheets Attached 2. ALL ELECTRICAL WORK SHALL COMPLY WITH 4 `� t: ; T THE 2017 NATIONAL ELECTRIC CODE. Olt I i A MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Wheat Ridge T. .r — ! REV BY DATE COMMENTS REV A AM 01/04/18 REDUCED SYSTEM SIZE UTILITY: Xcel Energy (CO) CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER J B-80011912 00 CUSTOMER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE RYAN KOCKLER 4.88 KW PV ARRAY Carlos Israel Quijano BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 2728 PENTON ST T - 5 L n ERS E THE RECIPIENT"S ORGANIZATION, EXCEPT IDN CONNECTION WITH MODULES: WHEAT RIDGE, CO 80214 THE SALE AND USE OF THE RESPECTIVE (16) Hanwha Q—Cells # Q.Peak— G4.1/SC305 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE PERMISSION of TESLA INC. SOLAREDGE SE380OH-USOOOSNU2 COVER SHEET 1 4 1/4/2019 N v fV 00 cD 0 3 Cn Front 01 LADDER ACCESS ,QQ LIEF D0 E. pFy�fi 7 9: 6/2019.: •/fdAl. AL ONLY" doD19.11' ai9 dby Abeia,do De DN: dc -local, tic-Sda2'iry, o�-9da2iry Users. ou-Mawtlame. De Vera a^°a° �Ga irycom Date: 2019,01 16 0— (; j 1, i 9tl] boo (;j1,i tsl PITCH: 19 ARRAY PITCH: 19 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 19 ARRAY PITCH: 19 MP2 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 19 ARRAY PITCH: 19 MP3 AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 19 ARRAY PITCH: 19 MP4 AZIMUTH:0 ARRAY AZIMUTH:0 MATERIAL: Comp Shinqle STORY: 2 Stories I FC;FNn (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS SITE PLAN Scale: 1/8" = 1' 0 1' 8' 16' N w E S CONFlDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -80011912 00 CUSTOMER: UESMPIION: RYAN KOCKLER 4.88 KW PV ARRAY © I DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS 0° DISTRIBUTION PANEL & LABELS LC LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Rso RAPID SHUTDOWN O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r, it `I INTERIOR EQUIPMENT IS DASHED L =/J SITE PLAN Scale: 1/8" = 1' 0 1' 8' 16' N w E S CONFlDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -80011912 00 CUSTOMER: UESMPIION: RYAN KOCKLER 4.88 KW PV ARRAY UCarlos Israel Quiano j T - 5 L n MOUNTING SYSTEM: BENEFIT OF ANYONE EXCEPT TESLA INC., NOR FENTON ST — SHALL IT BE DISCLOSED IN WHOLE OR IN2728 ZS Comp V4 wFlashing—Insert PART TO OTHERS OUTSIDE THE RECIPIENTS WHEAT RIDGE, CO 80214 MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) Hanwha Q—Cells # 0.Peak— G4.1/SC305 PAGE NAME: SHEET: REV: DATE - INVERTER: SOLAREDGE # SE380OH—USOOOSNU2 TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC' SITE PLAN 2 a 1/4/2019 (N) P\ T I'1l.HL F''V J1VC V1CVV SVJ NTS PV MODULE 5/16"x1.5" BOLT WITI 5/16" FLAT WASHEI ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK ZEP FLASHING INSERT (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW — (2-1/2" EMBED, MIN) (E) RAFTER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EOUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. #_qAN� JOB NUMBER: JB -80011912 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert MODULES- (16) ODULES(16) Hanwho Q—Cells # Q.Peak—G4.1 / INVERTER: SOLAREDGE # SE3800H—USOOOSNU2 INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. RYAN KOCKLER 2728 FENTON ST WHEAT RIDGE, CO 80214 Q��O LIEF Q C04:27 "STRUCTURAL ONLY" Digitall signed by Abela rdo De Abelardo DNAr—local do S.W,C4, u=S.""ity Users, o -Hawthorne. —Aelardo De De Vera � ilbadew,aa@wL—gcom Date: 2019.01.16094813 08'00' 4.88 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS vw °4 Wheat WOO auddin9 p�vis�h lJ Carlos Israel Quijano SHEET: REV: DATE.- 3 ATE3 0 1/4/2019 T=SLn ;�4 0 LIEF r o 0;1�1 6/2019. .';��c�' . ' ................ °�'/-AVA - ti ,,STRUC AL ONLY' Abelardo pad°Y9,:d'°�ary De ou=5"IaKity Users, De Vera °9=Ha"me,m-Abeardo De Veta, em 9.01.1 vera@s40 WOO Date:l019.01.160940:a0 OB'00' JB -80011912 00 31 CONCONFIDENTIAL AINEDSHALL NOT BE INFORUSED FOR THE HEREIN M "DMS RYAN KOCKLER 4.88 KW PV ARRAY Carlos Israel Quijano T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 2728 FENTON ST PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES WHEAT RIDGE, CO 80214 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) Hanwha Q—Cells # Veak—G4.1/SC305 SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME PERMISSION OF TESLA INC. SOLAREDGE # SE380OH-USOOOSNU2 UPLIFT CALCULATIONS 6 a 1/4/2019 DESIGN SUMMARY 01.16.2019 Version #74.1 Job#80011912 Jobsite Specific Design Criteria Design Code Importance Factor Ultimate Wind Speed Exposure Category Ground Snow Load I V-Ult pg ASCE 7-10 1.0 135 mph C 30.0 psf Fig. 1609A Section 26.7 ASCE Table 7-1 MPSpecific Design Information MP Name MP1 MP3 o Roofin Com Roof Com Roof C Standoff Comp Mount SRV Comp Mount SRV Pitch 19° 19° ® SU/RLL: PV 17.9 psf 17.9 psf SLIRLL: Non -PV 21.0 pst 21.0 Psf Standoff S acin and La out MP Name MPI MP3 ELr�X-Cantilever X-S acin 64" 64" y 24" 24" cYS cin 39" 39" m Y -Cantilever NA NA XS acin 48" 48" X-Candiever 20" 1 20" o YS acin 65" 65" o Y Cantilever NA NA Layout Staggered Sta g. red X and Y are maximums that are always relative to the structure framing that supperts the PV. X is across rafters and Y is along rafters. JB -80011912 00 31 CONCONFIDENTIAL AINEDSHALL NOT BE INFORUSED FOR THE HEREIN M "DMS RYAN KOCKLER 4.88 KW PV ARRAY Carlos Israel Quijano T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 2728 FENTON ST PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES WHEAT RIDGE, CO 80214 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) Hanwha Q—Cells # Veak—G4.1/SC305 SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME PERMISSION OF TESLA INC. SOLAREDGE # SE380OH-USOOOSNU2 UPLIFT CALCULATIONS 6 a 1/4/2019 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD AT PANEL WITH IRREVERSIBLE CRIMP Panel Number: NoMatch Meter Number: 45 341 146 Inv 1: DC Ungrounded INV 1 - (1 )SOLerter; j� W,24O /208V, 9%;H LABEL: Inverter; 3 00W,240V/208V,99%;HD Wave w�nifed Disco and ZB,AFCI - (16)Hanwha Q-Cells # Q.PeokTC, 4 MM, Bl PV Module; 305 ,279.2PTC, 4 MM, Black Frame, MC4, ZEP, 1000V TYPE EC # 8041 INV 2 Overhead Service Entrance Voc: 40.05 Vpmox: 32.62 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 150A MAIN SERVICE PANEL E 15OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING MILBANK CUTLER-HAMMER 150A/2P Meter Socket Disconnect 2 SOLAREDGE SE3800H-USOOOSNU2 (E) LOADS A B �4a� • u L2 l 20A/2P 1 - - m n - - - - - GND - — - ---------------------- N _EGG DC+ GEC - - - �iN Dc- 1 Dc- Dc- _ MP 1 3: 1x16 /11' EGC— EGC i i — ————————————————— ——————— —— —— —— — — ———— I N I I EGC/GEC — z z c� GEC TO 120/240V SINGLE PHASE UTILITY SERVICE I I L City of Wheat Ridge Building Division l Voc* = MAX VOC AT MIN TEMP 0 (1)GE # THOL2120 PV BACKFEED BREAKER Breaker, 20A/2P, 2 Spaces A (1)MILBANK / U4801-XL-5T9 Meter Socket; 200A, #6-350, Ringless A n PV (16)SOLAREDGE ! P400-5NM4MZM PowerBox Optimizer;400W, ZEP D� - (3) MILBANK # K4977-INT Load-Side Tap Connector, 100A, #12 - 1/0 AWG �(1)CUHAMMER # DG221URB Disconnect; 30A, 240Vac, Non-Fusible, NEMA 3R - (1)CUTLER-HAMMER f DG03ONB Ground/Neutral Keit; 30A, General Duty (DG) (1 )AWG #10, THWN-2, Block O (1 )AWG #10, THWN-2, Red (2)AWG #10, PV Wire, 60OV, Block O (1 )AWG #10, THHN/THWN-2, Green EGC Voc* = 500 VDC Isc = 15 ADC Vmp = 350 VDC Imp= 13.76 ADC (1 )AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC {1 )Conduit Kit; 3/4' EMT - (1 )AWG #8, THWN-2, Green EGC/GEC - ( 1 ) Conduit Kit: 3/4' EMT CONTAINED AL THE INFORMATION HEREIN JOB NUMBER: JB-80011912 0o CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR RYAN KOCKLER 4.88 KW PV ARRAY Carlos Israel Quijano T 5 L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 2728 PENTON ST n PART TO OTHERS OUTSIDE THE REgPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH WHEAT RIDGE CO 80214 MODULES THE SALE AND USE OF THE RESPECTIVE (16) Hanwha Q-Cells # 0.Peak— G4.1/SC305 SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: INVERTER: PERMISSION OF TESLA INC. SOLAREDGE # SE380OH—USOOOSNU2 THREE LINE DIAGRAM 7 a 1/4/2019 ELECTRICAL CALCULATIONS CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: JB -80011912 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert MODULES (16) Honwho Q—Cells # Q.Peak—G4.1/ INVERTER: SOLAREDGE # SE380OH-USOOOSNU2 Load Breaker Other 40A/2P Other 40A/2P Other 30A/2P Laundry 20A/1P Bathroom 20A/11? Lighting Circuit 15A/1P Lighting Circuit 15A/1P Lighting Circuit 15A/1P Lighting Circuit 15A/1P Small Appliance 20A/11? Small Appliance 20A/1P NEC 220.83 - Version 3.0 NEC 220.83(B) "Existing Dwelling Unit.... to determine if the existing service ... is of sufficient capacity ... The following percentages shall be used for existing loads ... First 8 kVA of load at 100%, Remainder of load at 40% NEC 220.83(6)(1) General lighting and general -use receptacles at ... 3 volt-amperes/ftp as determined by 220.12. Floor Area (3VA/sq ft) I Ft I VA 20521 6156 NEC 220.83(B)(2) 1500 VA for each 2 -wire, 20 -ampere small -appliance branch circuit and each laundry branch circuit covered in 210.11(C)(1) and (C)(2). NEC 220.83(B)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... landl water heaters" Qty I VA Small Appliance Circuits 12 18000 Laundry Circuits 1 1500 Bathroom Circuits 1 1500 NEC 220.83(B)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... landl water heaters" Total General Load (non -A/C load) 48276 VA First 8 kVA of load at 100% 8000 I General Calculated Load (non -A/C load) 24110 VA I NEC 220.83(B) The larger connected load of air-conditioning or space -heating, but not both, shall ha ii -,ad fatl 100 Percent of Load Breakerl VA Other 40 7680 Other 40 7680 Other 30 5760 Total General Load (non -A/C load) 48276 VA First 8 kVA of load at 100% 8000 I General Calculated Load (non -A/C load) 24110 VA I NEC 220.83(B) The larger connected load of air-conditioning or space -heating, but not both, shall ha ii -,ad fatl 100 Percent of Load Max Heating and Air -Conditioning load 0 VA Total Load Sum of General Calculated Load 24110 VA & Heating and A/C Load 100.46 A RYAN KOCKLER 4.88 KW PV ARRAY 2728 FENTON ST WHEAT RIDGE, CO 80214 PAGE NAME.- ELECTRICAL AME:ELECTRICAL LOAD CALCULATIONS DESIGN: Carlos Israel Quijano SHEET: REV: DATE: OadCaics1/4/2019 T=SLn Breakerl VA Sum of A/C Equipment0 Sum of Electric Furnaces 0 0 0 Max Heating and Air -Conditioning load 0 VA Total Load Sum of General Calculated Load 24110 VA & Heating and A/C Load 100.46 A RYAN KOCKLER 4.88 KW PV ARRAY 2728 FENTON ST WHEAT RIDGE, CO 80214 PAGE NAME.- ELECTRICAL AME:ELECTRICAL LOAD CALCULATIONS DESIGN: Carlos Israel Quijano SHEET: REV: DATE: OadCaics1/4/2019 T=SLn CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 2728 Fenton St ---------------------- F ----� SOLAR PHOTOVOLTAIC ARRAYS) --------------------------- INVERTER -------------------------- INVERTER AND DC DISCONNECT INVERTER AND DC DISCONNECT AC DISCONNECT UTILITY SERVICE PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: J13-80011912 00 MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert MODULES (16) Hanwho Q—Cells # Q.Peak— G4.1/SC305 INVERTER: SOLAREDGE # SE380OH—USOOOSNU2 JB -80011912-00 RYAN KOCKLER 2728 FENTON ST WHEAT RIDGE, CO 80214 DESCRIPTION: 4.88 KW PV ARRAY PAGE NAME: SITE PLAN PLACARD Carlos Israel Quijano SHEET: REV: DATE: 8 a 1/4/2019 0% �0at��d90 J`S`00 i T=SLn A WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION A WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Label Location: (C)(CB)(JB) Per Code: NEC 690.31.G.3 Label Location: (DC)(INV) Per Code: NEC 690.13.B Label Location: (DC) (INV) Per Code: NEC 690.53 Label Location: (AC)(POI) Per Code: NEC 690.13.6 Label Location: (AC) (POI) Per Code: NEC 690.54 Label Location: (AC)(POI) Per Code: NEC 690.17.E Label Location: (POI) Per Code: NEC 705.12.D.2 Label Set AWARNING__ ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED Label Location: (INV) Per Code: CEC 690.56(C) Label Location: (DC) (INV) Per Code: NEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection SoiarCity ®pSolar Next -Level PV Mounting Technology , SolarCitY ®pSolar Next -Level PV Mounting Technology .ZS Comp for composition shingle roofs Components Mounting Block Array Skirt Part No. 850-1633 Part No. 850-1608 or 500-0113 Listed to UL 2703 Listed to UL 2703 Interlock Part No. 850-1388 or 850-1613 Listed to UL 2703 1 Flashing Insert Grip Ground Zep V2 Part No. 850-1628 Part No. 850-1606 or 850-1421 Part No. 850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 QGpKPAT/ e`er Description PV mounting solution for composition shingle roofs FAa Works with all Zep Compatible Modules O' Auto bonding UL -listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Captured Washer Lag End Cap LISTED Part No. 850-1631-001 Part No. Specifications 850-1631-002 (L) 850-1586 or 850-1460 850-1631-003 (R) 850.1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No. 850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM DC Wire Clip Part No. 850-1509 Listed to UL 1565 GdH pt Vl�eati Rtd9e �t�ts. 00 gilt`o — tf This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar s sole warranty is contained in the written product warranty for each producL The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM solar SolarEdge Power Optimizer - Zep Compatible TM Module Add -On For North America P300-ZEP, P400-ZEP Compatible with Zep Groove framed modules — Certified Zep CompatibleTM' bracket — Attaches to module frame without screws - reduces on -roof labor and mounting costs — Power optimizer equipment grounded through the bracket — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety ,_n -� �lcf _,_ _ ra= �� - v. _pan a� .aai� www solaredge.us so I a r' • • SolarEdge Power Optimizer - Zep Compatible TM Module Add -On For North America P400-ZEP �P300-ZEP(for60-cell PV modules) _ P400-ZEP(11or72&96-cellmodules) INPUT Rated Input DC power") ......................... r") ................ ............ _ ...... Absolute Maximum Input Voltage (Voc at lowest temperature) MPPT Operating Range Maximum Short Circuit Current (Isc) .._.-.- ............. ..._.. _ Maximum DC Input Current Maximum Efficiency _.......... ........................ Weighted Efficiency _ _........_.............. 300 400 W 48 80 Vdc 8-48 i........ 8-80 ....... ...- ........ Vdc .................. _ _. 10 10.1 Adc 12.5 _.. .....,.._. 12.63 .._._ .. _._ Adc ..... _._. . ............. 99.5 % 98.8 I I % OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, JEC61000-6-3 Safety i IEC62109 1(dass II safety), UL1741 ROHS Yes INSTALLATION SPECIFICATIONS _ Maximum Allowed System Voltage 1000 Vdc Dimensions including mounting bracket (WxLxH) 128 x 196 x 27.5 / 5 x 7.71 x 1.08 128 x 196 x 35 / 5 x 7.71 x 1.37 mm/in 128x152x35/ Dimensions excluding mounting bracket (WxLxH) 128 x 152 x 27.5 / 5 x 5.97 x 1.08 5 x 5.97 x 1.37 mm/in Weight (including cables and mounting bracket) 720/1.6 840/1.9 kg / Ib Input.Co...nnector MC4 Compatible ....... ........ _........ . ... Output Connector Double Insulated; MC4 Compatible Output Wire Length 0.95/3.0 1.2/3.9 m / ft 5 .g..... _.._.. .. ..........._ _ O ........ 0-+ 8 Protection Ratin IP68 / NEMA 6P Relative Humidity 0-100 % N gated STC power of the module. Module of up to+5%power tolerance allowed. 0 PHASE \A 2 G ag PV SYSTEM DESIGN USING A SINGLE PHASE THREE PHASE THREE SINGLE PHASE SOLAREDGE INVERTER(2) HD -WAVE 208V 480V Minimum String Length (Power Optimizers) 1 8 10 18 Maximum String Length (Power Optimizers) 25 25 50 aS 5700 (6000 with CJs Maximum Power per String SE7600H-US) 5250 6000 12750 W Parallel Strings of Different Lengths or Yes Orientations For detailed string sizing information refer to: http://www.sol,redg,.c,m/sites/defaultifiles/sVing_sizing-na.pdf 'q�" W The new high-performance module Q.PEAK-G4.1 /SC is the ideal solution for all applications thanks to its innovative cell technology Q.ANTUM ULTRA and a black Zep Compatible TM frame design for improved aesthetics, easy installation and increased safety. The world -record cell design was developed to achieve the best performance under real conditions - even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS ►If Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 18.6%. *n INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. a ENDURING HIGH PERFORMANCE Long-term yield security with Anti -PID Technology', QCELLS Hot -Spot -Protect and Traceable Quality Tra.QTM. TOP BRAND PV OA RELIABLE INVESTMENT 2016 Inclusive 12 -year product warranty and 25 -year linear performance guarantee 2. OMPAT O.P. Phntnn Q CUS module201solar moduM 2U14 1cov , THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings ' APT test conditions; Cells at -1500V against grounded, with conductive me- tal foil covered module surface, 25°C, 168h See data sheet on rear for further information. Engineered in Germany OCELLS Format 65.7 in x 39.4in x 1.57 in (including frame) (1670mm x1000mm x 40mm) Weight 44.09lbs (20.01kg) Front Cover 0.13 in (3.2 mm) thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 x 10 monocrystalline Q.ANTUM ULTRA solar cells Junction box 2.60-3.03 in x 4.37-3.54 in x 0.59-0.75 in (66-77 mm x 111-90mm x 15-19mm), Protection class IP67, with bypass diodes Cable 4mmz Solar cable; (+) 47.24 in (1200 mm), (-) 47.24 in (1200 mm) Connector Multi -Contact MC4, IP68 POWER CLASS 300 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5W /-0 W) Power at MPP' P„ 1W] Short Circuit Current* Iu [A] E Open Circuit Voltage* V. N] e 9.26 Current at MPP* la„ [A] Voltage at MPP* VM„ IV] Efficiency' rl I%] MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3 f Current at MPP* 295 300 305 295 300 305 9.70 9.77 9.84 39.48 39.76 40.05 9.17 9.26 9.35 32.19 32.41 32.62 z 17.7 s 18.0 2-18.3 Power at MPP' PM„ IW] 218.1 221.8 225.5 E Short Circuit Current* Iu [A] 7.82 7.88 7.94 e Open Circuit Voltage* V. [V] 36.92 37.19 37.46 f Current at MPP* I„e, [A] 7.20 7.27 7.35 Voltage at MPP* VM IV] 30.30 30.49 30.67 11000 W/m2, 25 °C, spectrum AM 1.5G ' Measurement tolerances STC t3 %; NOC t5 % 3800 W/m=, NOCT, spectrum AM 1.5G 'typical values, actual values may differ 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE TEMPERATURE COEFFICIENTS Temperature Coefficient of Iss Temperature Coefficient of P„®e Maximum System Voltage Vsys Maximum Series Fuse Rating Design load, push (UL)' Design load, pull (UL)' re EARS At least 98% of nominal power during first year. Thereafter max. 0.6 % degradation per year. At least 92.6% of nominal paver up to 10 years. At least 83.6% of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. _-i _-_______ W me me Ime IRRADIANCE w t9 Typical module performance under low irradiance conditions in comparison to STC conditions (25"C, IOOOW/m'). U [%/K] +0.04 Temperature Coefficient of V. 0 [%/K] -0.28 y ll -0.39 Normal Operating Cell Temperature NOCT it 113 t5.4 (45 t3 °C) IV] 1000 (IEC) / 1000 (UL) [A DC] 20 [Ibs/ft'] 75 (360OPa) [Ibs/ft2] 55.6 (2666 Pa) Safety Class II Fire Rating C (IEC) /TYPE 1 (UL) Permitted module temperature -40°F up to +185°F on continuous duty (-40°C up to +85°C) 'see installation manual QUALIFICATIONS r CERTIFICATES PACKAGING INFORMATION UL 1703; CE -compliant; Number of Modules per Pallet 26 IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class A Number of Pallets per 53' Container 32 t. -Ar, C ♦ GO: •W �, k Number of Pallets per 40'Container 26 F` c 3 �Oj � Pallet Dimensions ( L x W x H) 68.7 in x 45.3 in x 46.1 in (1745mm x 1150mm x 1170mm) �* Pallet Weight City 011254 lbs (569 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha O CELLS America Inc. WV100t Rid90 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL +1 949 748 59 96 1 EMAIL inquiry®us.q-cells.com I WEB www.p-cells.us gIding Division solar -.• SolarEdge Single Phase for North America SE3000H-US / SE380OH-US / SE5000H-U SE760OH-US / SE10000H-US / SE11400H- 9 50181' —HEll a..: Irr��• 's. Optimized installation with HD -Wave technology Specifically designed to work with power optimizers Record-breaking efficiency - Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 - UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small — High reliability without any electrolytic capacitors — Built-in module -level monitoring 11111111111' WIL D — Outdoor and indoor installation wave — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) — Simple configuration and commissioning with smartphone app and built in Wi-Fi (SE1000OH-US, SE11400H-US) C,%ADA Gr MW - •yE 'r ETHERLANV APA'. solar' • • Single Phase Inverters for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US/SE1140OH-US SE3000H-US SE380OH-US SESOOOH U5 I SE6000H-US I SE760OH-U5 I SE10000H-U5 I SE1140OH-US OUTPUT - Rated AC Power Output Max. AC Power Output AC Output Voltage Min.-Nom.- - in:Nom.- - 208, - 229.).. , , ... . AC Output Voltage Min. -Nom: Max: 211 - 2!Q-. 264 AC Frequency (Nominal) Maximum Continuous Output Current 208V .............................. Maximum Continuous Output Current 240V .............................. GFDI Threshold ....................................... Utility Monitoring, Islanding Protection, Country Configurable Thr chnWc 3000 UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to LLL M -U/ 5000 60007600 Maximum DC Power 10000 11400 VA .......3300.@208V. , , ..... , . _ ; Maximum Input Volta&e ....... 480 . Vdc 3000 3800 @240V 5000 6000 760010000 MaximumInput Current 208V 11400 VA ..................3300 .� 208 y.................................. Adc ................................ 8 5 . 13.5 f 16.5 20 I .. 27 30 5 Adc ✓ ✓ 45 ...... ... .. _... _. ....... . Adc .. ........ ........ .... ac.... ................................................................. ✓ ✓✓ _ .I I ✓ .............. ✓ ............ I. ✓ �.. Noise � ................ ......... ......... ............ .....j.......... ......... ......... .. ...... 59.3 - 60 - 60.51'1 I.. ......... I... ................ .......... 76 . ....... _. ...... ..... . ..Vac.... H?. .... w 16 24A _..... ................. .- . ..i.. Operating Temperature Range -13 to +140 / -25 to +601"1(-40 F / -40'C option)(') ... . . .............................. 12..5 Protection Rating 21..............25 I 32 42 47.5 A .............16............. ............................. ...............................1..........................I.................. I ............. I.... A..... i Yes mrtrt UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to LLL M -U/ Grid Connection Standards Maximum DC Power 46505900 7750 9300 11800 15500 17670 W Transformer -less, Ungrounded I Yes ; Maximum Input Volta&e ....... 480 . Vdc Nominal DC Input Voltage 3/4" minimum / 20-4 AWG 380 . ..... 400 Vdc MaximumInput Current 208V _ __. _ _..... 9 13:5 / AWG Range.......... Adc Maximum Input Current 240V 8 5 10.5 13.5 f 16.5 20 I .. 27 30 5 Adc Max Input Short Circuit Current ... 17.7 x 14.6 x 6.8 / 4SO x 370 x 174 45 ...... ... .. _... _. ....... . Adc Reverse Polarrty Protection i Yes Ground -Fault Isolation Detection _ 600kQ Sensitivity 38.8/17.6 40.1/182 . Maximum Inverter Efficiency Noise <25 CEC Weighted Efficiency99 _. _ .......... ............... .......... 76 . Nighttime Power Consumption I <2-5 w ADDITIONAL FEATURES Supported Communication 85485, Ethernet, ZigBee (optional), Cellular (optional) Interfaces Revenue G_down NEC 2014 rade Data, ANSI C_and 1210 Optiona11:1 Ra pid ShutAutomatic Rapid Shutdown upon AC Grid Disconnect - 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to LLL M -U/ Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) ....... _.... .. Emissions _. FCC Part 15 Class B I __ INSTALLATION SPECIFICATIONS _ AC Output Conduit Size / AWG 3/4" minimum / 20-4 AWG Rang? ................. _.... .........t. DC Input Conduit Size / # of Strings _ __. _ _..... _. g minimum / 1-3 strings / / AWG Range.......... 3/4• minimum / 1-2 strings / 14-6 AWG 14-6 AW _ . 21.3x14.6 21.3x14.6 i Dimensions with Safety Switch 17.7 x 14.6 x 6.8 / 4SO x 370 x 174 x 7.7 / 540 x x 7.3 / 540 x in/mm (HxWxD) i 195 7 x 1 379.095 .,... . Weight with Safety Switch _ _.. ... 22 / 10 25.,A/11_4 26.2 / 11.9 38.8/17.6 40.1/182 . Ib / kg Noise <25 <SO dBA Natural convection and internal fan (user Coolingj Natural Convection acea e _..... ................. .- . ..i.. Operating Temperature Range -13 to +140 / -25 to +601"1(-40 F / -40'C option)(') ... . . F / 'C Protection Rating NEMA 311 (Inverter with Safety Switch) _... Itl For other regional settings please contact SolarEdge support Rl Revenue grade inverter P/N: SE—H-USOOONNQ lel For power de -rating information refer to: https://www.solaredge.com/sites/defautt files/se-tempemture-derating-note-na.pdf Is1-40 version P/N: SExxxxH-USOOONN114 d We 11:59 P.M. Plan Review ( due at time o Credit Card Payment: Use credit card lis- • _ 41 City of Wheat Ridge Res. Add Structure PERMIT - 081436 ;RMIT NO: 081436 ISSUED: 12/15/2008 )B ADDRESS: 2728 FENTON ST EXPIRES: 06/13/2009 1SCRIPTION: Move existing 8' x 10' storageshed on property CONTACTS r 720/297-2824 Mike Brary PARCEL INFO E CODE: UA USE: UA DIVISION: 0535 BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: .00 FEES ermit Fee 35.00 DM * TOTAL 35.00 itions: Owner/Contractor is responsible for locating proeprty lines and tructing improvements according to the approved plan and required lopment standards. The City is not responsible for inaccurate information .itted within the plan set and any construction errors resulting from curate information. R-1C Approved hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable rdinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all °asurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this >plication and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other pplicable Wheat Ridge rsd/finances, forr{ww k under this per tt Plans subject to field inspection. Alm i~/ ~7, O zim ub C.7 of This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the '.State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire 1BO days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. If this permit expires, a new permit may be acquired for a fee of one-half the amount normz,lly required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any viol ap)1.on of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review iays~7„}'g to field inspections. Ofticlal care T LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS. DAY si2008 15:37 FAY 3082852857 p1ANNING 303235284U I---. JIJ' - t ra a Shad Place ant Permit un (For storage shed that Do NOT exceed 120 sq ft in floor area) 0U I4 pepartment of Planning and pevelopment City of Wheat Ridge 1500 West 29"` puenue Wheat131due, co 80215 -303.235.2555 Property Owner: 6*Mhq_Ve-Zr~- Address: 2Z 2S ST, Properly Phone: .nntractor: Phone: 1 hereby certHy that the setback distances proposed for this permit application are accurate, and do not violate applicable of record; all a- that I have ge or covenants, easements or restrict Code (U B C)tand all ordinances, rules or regulations of the City of wheat Rid measure application nis ashown nd that allegati n made are ac u racopl ence with il s and Wheat Ridge Building all conditions printed on is sume full Lther Ucable WheatRidge ordinances, for work under this permit. WCONTRACTOR) Signature: &~'L ~~C10~ /d+E'C Ckt~" Use: S leBCrlntian:S~rr'G Zoning: Sq. Ft.: Building Setbacks -Side: Rear:60~ Front: Approval: 11 Approval: No work of any manner shall be dons that will change the natural flow of storm water causing a orarnuuc v v. sPOG owner i contractor shat1 notify the building departmenttwenty-four (24) hours in advance for all an a llo oval of. any violation written approval an inspection. uleaoru egulation.permltfnr , nor an app The issuance of a permit or approval of drawings shall not w. construed of the provisions of the building codes or any ordinance, law, Sheds must be properly and securalY anchored at all corners. ptE ravedpia°anuregnircdrJeveiaime°tstandatds se ctaflsnatresa ns[faloforinaccurate nrmataonsuumttdtedwi[ry~u app rile plan setand 81131 e011stfliCl ewers resulting from inaseuwatefnforntatfop Codes Administrator TO 39Vd 01G S213AIDdE M11314 1,99TELLEOE 2',0 :LT 800Z/LT/TT 12/11/2006 17:24 3037731664 METRO BROKERS DTC a K Y~f kb B r-f (b liE7 kc.i(- 27z U 3^t PAGE 03 l~Go c~l~a to ~xg~ ~rf~ D Lock?iotJ nrr -s ~lare~ S r Am~