Loading...
HomeMy WebLinkAbout3540 Chase Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECT 9, NO ICE 3iv- ilac / e r- Pe Inspection Type: `/ 0 3 - Q e Job Address: -3-5-44D C a S�- Permit Number: 'ir o ) S o I ) a 4� RAI �CGG-Z ❑ No one available for inspection: Time JLoo /PM Re -Inspection required: Yes S 01f,101 — When corrections have been made, call for re -inspection at 303-234-5933 Date: 7// 7V // 0 Inspector: 1g l 1 E r+ f o s z' DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Solar PERMIT - 201801128 PERMIT NO: 201801128 ISSUED: 05/08/2018 JOB ADDRESS: 3540 Chase ST EXPIRES: 05/08/2019 JOB DESCRIPTION: Installation of roof mounted grid tied PV Solar System 3.0 KW DC. *** CONTACTS *** OWNER (720)532-7357 TALAMANTEZ ANNA M SUB (385)482-0045 James E. maule 170691 Blue Raven Solar Holdings *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,622.46 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work t be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable mini ipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authdr e7 to obtain this permit and perform the work described and approved in conjunction with this permit. I further attes a le ally a rized to include all entities named within this document as parties to the work to be performed and tha or o be p r nne disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or ACTOR (Circle one) Date 1, This permit was issued basco.4h the information provided in thepermit application and accompanying pplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinanceh regulation of this jurisdiction. Approval of work is subject to field inspection. A. g W A. . r Signature of Chief Buildm.�g,,6mcial Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 412D I is City of ')e,o0!5rWh6atP.j,d 1 FOR OFFICE USE ONLY Date: / 1 ,1t ! C—/ 7 PianlPermit #_ / Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permits(cDci.wheatridoe.co.us Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3540 Chase Street, Wheat Ridge, Colorado, 80212, United States Property Owner (please print): Anna Talamantez Phone: Property Owner Email: cre8peace@aol.com Mailing Address: (if different than property address) Address: City, State, Zip: Arch itect/Engineer: Architect/Engineer E-mail: Contractor: Blue Raven Solar LLC Phone: Contractors City License #: 00 6 C% / Phone: 385-482-0045 Contractor E-mail Address: permitting.department@blueravensolar.com Sub Contractors: Electrical: Plumbing: Mechanical: W.R. City License # W. R. City License # W. R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ® OTHER (Describe) Rooftop Solar Photovoltaic System (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used. etc.) Sq. Ft./LF Amps Roo -300 KW Btu's Squares PV S)IC,C Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $7,622.46 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Signature (first and last name): _ k4 ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY DATE: 04/19/2018 OCCUPANCY CLASSIFICATION: Building Division Valuation: $ 00 o gaga I12B Ems, : 1-N I,:_ -Ac- April 18, 2018 To: Blue Raven Solar 1220 S. 630 E. Ste. 430 American Fork, LIT. 84003 Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, CO 80021 530-864-7055 Domusstructural@gmail.com Subject: Certification Letter t� ;6' Talamantez Residence "," 43019 N 3540 Chase St. •, Wheat Ridge, CO. 80212''•..."'��»s Digitally signed by John Calvert To Whom It May Concern, Date: 2018.04.1813:21:38-06'00' A jobsite observation of the condition of the existing framing system was performed by an audit team of Blue Raven Solar as a request from Domus Structural Engineering. All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project, the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof. The structural review only applys to the section of the roof that is directly supporting the solar PV system and its supporting elements. The observed roof framing is described below. If field conditions differ, contractor to notify engineer prior to starting construction. The roof structure of (MP1) consists of composition shingle on roof plywood that is supported by 2x6 rafters @ 24"o.c. paired with 2x6 ceiling joists @ 16"o.c.. The rafters have a max projected horizontal span of 13'-6", with a slope of 23 degrees. The rafters are connected at the ridge to a ridge board and are supported at the eave by a load bearing wall. The existing roof framing system of (MP1) is judged to be inadequate to withstand the loading imposed by the installation of the solar panels. Structural reinforcement is required. Sister upgrade is required for (MP1) on all rafters with horizontal spans greater than 9'-4" and that directly support solar. Stitch new 2x6 DF#2 to existing member with Simpson SDW 22300 screws @ 16"o.c. or 10d nails @ 6"o.c.. Lap as needed with 4'-0" minimum lap per attached detail. The spacing of the solar standoffs should be kept at 72" o.c. for landscape and 48" o.c. for portrait orientation, with a staggered pattern to ensure proper distribution of loads. The scope of this report is strictly limited to an evaluation of the fastener attachment, underlying framing and supporting structure only. The attachment's to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading. All panels, racking and hardware shall be installed per manufacturer specifications and within specified design limitations. All waterproofing shall be provided by the manufacturer. Domus Structural Engineering assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Design Criteria: • Applicable Codes = 2012 IBC/IRC, ASCE 7-10, and NDS -12 • Roof Dead Load = 9 psf (MP1) • Roof Live Load = 20 psf • Wind Speed = 135 mph, Exposure C, Risk Category II • Roof Snow Load = 30 psf C • Attachments: (1) 5/16" dia lag screw with 2.5" min embedment depth, at spacing shown above. Please contact me with any further questions or concerns regarding this project. Sincerely, John Calvert, P.E. Project Engineer Talamantez Residence, Wheat Ridge, CO 1 0 x"T u s Domus Structural Engineering, LLC P.O. Box 6986 ;- T I U C T f'I R I, Broomfield, CO 80021 4Ne Q _f N E E R ING L 1, C, 530-864-7055 DomusstructuraI@gmail.com Gravity Loading Roof Snow Load Calculations p9 = Ground Snow Load = 30 psf pf = 0.7 Ce Ct I p9 (ASCE7 - Eq 7-1) Ce = Exposure Factor = 1 (ASCE7 - Table 7-2) Ct = Thermal Factor = 1 (ASCE7 - Table 7-3) 1 = Importance Factor = 1 pf = Flat Roof Snow Load = 30.0 psf PS = CSPf (ASCE7 - Eq 7-2) Cs = Slope Factor = 1 pS = Sloped Roof Snow Load = 30.0 psf PV Dead Load = 3 psf (Per Blue Raven Solar) PV Svstem Weight Weight of PV System (Per Blue Raven Solar) 3.0 psf X Standoff Spacing = 4.00 ft Y Standoff Spacing = 5.50 ft Standoff Tributary Area = 22.00 sft Point Loads of Standoffs 66 Ib Note: PV standoffs are staggered to ensure proper distribution of loading Roof Live Load = 20 psf Note: Roof live load is removed in area's covered by PV array. Roof Dead Load (MP1) Composition Shingle 4.00 Roof Plywood 2.00 Double 2x6 Rafters @ 24"o.c. 2.30 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.70 Total Roof DL (MP1) 9.0 psf DL Adjusted to 23 Degree Slope 9.8 psf Talamantez Residence, Wheat Ridge, CO 2 omu S =� 1 (3 I NEER t N Ci Wind Calculations Per ASCE 7-10 Components and Cladding Inout Variables Wind Speed 135 mph Exposure Category C Roof Shape Gable/Hip Roof Slope 23 degrees Mean Roof Height 20 ft Effective Wind Area 19.3 ft Desion Wind Pressure Calculations Wind Pressure P = qh*G*Cn ch = 0.00256 * Kz * Kzt * Kd * V12 (Eq. 30.3-1) Kz (Exposure Coefficient) = 0.9 (Table 30.3-1) Kzt (topographic factor) = 1 (Fig. 26.8-1) Kd (Wind Directionality Factor) = 0.85 (Table 26.6-1) V (Design Wind Speed) = 135 mph (Fig. 26.5-1A) Risk Category= II (Table 1.5-1) qh = 35.69 0.6*qh= 21.42 Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, CO 80021 530-864-7055 Domusstructural@gmail.com Standoff Uplift Calculations -Portrait Fastener = 1 - 5/16" dia Lag �U tyo Zone 1 Zone 2 Zone 3 Positive GCp= -0.86 -1.51 -2.37 0.42 (Fig. 30.4-1) Uplift Pressure = -18.46 psf -32.34 psf -50.80 psf 15.1 psf X Standoff Spacing = 4.00 4.00 2.67 Y Standoff Spacing = 5.50 2,75 2.75 Tributary Area = 22.00 11.00 7.33 Footing Uplift = -406 Ib -356 Ib -373 Ib Standoff Uplift Calculations -Landscape Zone 1 Zone 2 Zone 3 Positive GCp = -0.86 -1.51 -2.37 0.42 (Fig. 30.4-1) Uplift Pressure = -18.46 psf -32.34 psf -50.80 psf 10.0 psf (Minimum) X Standoff Spacing = 6.00 6.00 4.00 Y Standoff Spacing = 3.50 1.75 1.75 Tributary Area = 21.00 10.50 7.00 Footing Uplift = -388 Ib -340 Ib -356 Ib Standoff Uplift Check Maximum Design Uplift = -406 Ib Standoff Uplift Capacity = 450 Ib 450 Ib capacity > 406 Ib demand Therefore, OK Fastener Capacity Check Fastener = 1 - 5/16" dia Lag �U tyo Number of Fasteners = 1 Embedment Depth = 2.5 Pullout Capacity Per Inch = 250 Ib Fastener Capacity = 625 Ib w/ F.S. of 1.5 & DOL of 1.6= 667 Ib 667.2 Ib capacity > 406 Ib demand Therefore, OK Talamantez Residence, Wheat Ridge, CO 3 Do N1 f7 s Domus Structural Engineering, LLC P.O. Box 6986 �I Rt E C. "F t-' R A L Broomfield, CO 80021 EN G I N I L R f N G t, I,, C 530-864-7055 Framing Check Domusstructural@gmail.com (MPI) PASS - With Framing Upgrades w = 86 plf Dead Load 9.8 psf PV Load 3.0 psf Snow Load 30.0 psf Double 2x6 Rafters @ 24"o.c. Governing Load Combo = DL + SL Member Span = 13- 6" Total Load 42.8 psf Member Properties - Based on Upgraded Section Member Size S (in ^3) 1 (in"4) Lumber Sp/Gr Member Spacing Double 2x6 15.13 41.59 DF#2 @ 24"o.c. Check Bending Stress Fb (psi) = f'b x Cd x Cf x Cr (NDS Table 4.3.1) 900 x 1.15 x 1.3 x 1.15 Allowed Bending Stress = 1547.3 psi Maximum Moment = (wL^2)/8 = 1949.04 ft# = 23388.5 in# Actual Bending Stress = (Maximum Moment) / S = 1546.4 psi Allowed > Actual --100% Stressed -- Therefore, OK Check Deflection Allowed Deflection (Total Load) = U120 (E = 1600000 psi Per NDS) = 1.35 in Deflection Criteria Based on = Simple Span Actual Deflection (Total Load) _ (5*w*L^4) / (384*E*I) = 0.961 in = U169 > U120 Therefore OK Allowed Deflection (Live Load) = U180 0.9 in Actual Deflection (Live Load) _ (5*w*L"4) / (384*E*I) 0.674 in U241 > L/180 Therefore OK Check Shear Member Area= 16.5 in"2 Fv (psi) = 180 psi (NDS Table 4A) Allowed Shear = Fv * A = 2970 Ib Max Shear (V) = w * L 12 = 577 Ib C'. Allowed > Actual 19.5% Stressed Therefore, OK sms,� 0 Talamantez Residence, Wheat Ridge, CO 4 1X DECKING OR SHEATHING (N) INSTALL SIMPSON A34 CLIP. (E) RAFTERS (N) SISTER MEMBER TO BE FULL LENGTH. ATTACH TO (E) RAFTER W/ SIMPSON SDW22300 SCREWS STAGGERED TOP AND BOTTOM @ 16" O.C. (E; MINIMALLY NOTCH NEW - (E) CEILING JOIST SISTER RAFTER TO BEAR DIRECTLY ON (E) TOP PLATE OF WALL. OPTION 1 - FULL LENGTH SISTER SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE. SISTER RAFTER TO BEAR DIRECTLY ON (E) TOP PLATE OF WALL. (N) INSTALL SIMPSON A34 CLIP. TER MEMBER TO BE FULL IGTH. ATTACH TO (E) RAFTER W/ PSON SDW22300 SCREWS �GGERED TOP AND BOTTOM @ O.C. OPTION 2 - OVERLAPPED SISTER SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE. (N) SISTER RAFTER (N) SISTER RAFTER (E) RAFTER SECTION A -A I c, SISTER UPGRADE OPTIONS ngO�G, S PROJECT NAME: Rafter sister upgrade Scale: N.T.S. Domus Structural Engineering, LLC. Date: 4/5/18 P.O. BOX 6986 Project Number: Solar PV Broomfield, CO 80021 Project Description: Rafter sister upgrade detail and Drawn By: JAC Drawing Name: (530) 864-7055 specifications. Revisions: Domusstructural@gmail.com A S i S i B GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE (NEC), 2015 INTERNATIONAL RESIDENTIAL CODE (IRC), 2014 NATIONAL BUILDING CODE (NBC), 2015 INTERNATIONAL BUILDING CODE (IBC), 2015 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES. 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. 3. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS, SITE NOTES 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS, 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.261 5. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER NEC 250-648. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS. EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64C.1 B. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. 7. RIGID CONDUIT (ANDiOR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES. 8. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR) 9. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 10. UV RESISTANT CABLE TIES(NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A -B). 300.4 11. SOLADECK JUNCTION BOXES MOUNTED FLUSH W?ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. SOLAR CONTRACTOR 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703. IEC61646. IEC61730. 2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A SUITABLE SEALING COMPOUND. 6. DC VVIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM. 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W' SUITABLE WIRING CLIPS. B. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT AVAILABLE. 9. ALL INVERTERS, MOTOR GENERATORS. PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, DC COMBINERS. DC -TO -DC CONVERTERS, SOURCE CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM "ILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (B). 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. EQUIPMENT LOCATIONS 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY [NEC 110.26]. 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY [NEC 690.31 (A'kB)1 AND [NEC TABLE 310.15 (B)1. 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT TO THE UTILITY AC DISCONNECT, OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 5, ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. AERIAL VIEW ASCE 7-10 WIND SPEED: ffCf MPH IOCCUPANCY -R3 I SHEET INDEX GROUND SNOW LOAD: 30 PSF CONSTRUCTION - V -B PV1 - COVER SHEET EXPOSURE CATEGORY: C ZONING: RESIDENTIAL PV2 - PROPERTY PLAN SEISMIC DESIGN CATEGORY: B PV3 - SITE PLAN PV4 - EQUIPMENT & ATTACHMENT DETAIL PV5 - ELECTRICAL SINGLE LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS & STRING DIAGRAM PV7 M.BD CALCS. (IF NEEDED) PV8 L,f EL" LCAT1 OIS PV9 - STRINd °fit `SE O€: T(M1ZER SCOPE OF WORK DC SYSTEM SIZE: 3.0 kW DC ROOF TYPE: Comp Shingle MODULES: (10) Trinasolar 300 TSM-DD05A.05(Il) INVERTER(S): Enphase IQ6-60-2-US,---- RACKING: Unirac Sunframe Microrail Mounting & Racking System ANCHORED ON MAX 72 INCH CENTERS USING UL LISTED RACKING SYSTEM TO SPEC. UVAUMNEW-10'.15MI;s t .•f . C Reviewed for Code Compliance ,VOltd____ o p__ -Thr issuance of o prrmit or approval o/p7ons specifications and computabons-s shall not be a permit for, or on opprovo! of, any viaioli, to any of the provisions of the building code or of o" City otdinon.-es. pennies presuming to give authority to violate of cancel the provis7arrs of the "Wmg codes at other ordinances of the City snail not be valid Net -1 - BLUE RAVEN 1220 S. 630E 0 AMERICAN FORK,,LIT UT 84003 800-377-4460 VANIN.BLUERAVENSOLAR.COM ` O CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE 50883544 USED FOR THE BENEFIT OF O ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT REVISION BE DISCLOSED €N WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, H EXCEPT IN CONNEC TION'VVITH THE •- SALE AND USE OF THE RESPECTIVE N EQUIPMENT, VA'THOUT THE N PERMISSION C R N BLUERAVENSOL.=tR LLC.. BLUE } Cl) 0 00 0 O 0 Z v- V z�Z)t�rn <_j Q CD ' w CY). U 00 ZILL 0 O 0 Q UOQ U-1 0 U m U) w O 0-1n CUF- CU z 10 PROJECT NU 9BER N 50883544 /1b O O REVISION PV1 Lu H •- 0 00 N Q N Q>0 Cn cCU U O ;_ m w LL CUF- CU U Z } 0 U LU CU o CUc a� c� � o C/) Q 0 co DRAVVIN9 BY Eric Thomas DATE March 28, 2018 ti 10 PROJECT NU 9BER 50883544 /1b SHEET NAi4E COVER SHEET . AGE NUMBER REVISION PV1 DC SYSTEM SIZE: 3.0 kW DC ROOF TYPE: Comp Shingle (10) Trinasolar300TSM-DD05A.05(11) Enphase IQ6-60-2-US ----- INVERTER LEGEND EINVERTER & DC DISCONNECT 179B (E) SUBPANEL FI (N) LOAD CENTER I RAC DISCONNECT F11 UTILITY METER (SERVICE PANEL FB JUNCTION BOX FCOMBINER BOX PV PV REVENUE METER FIRE SETBACK EMT CONDUIT RUN (To BE DETERMINED IN FIELD) PV A,'IRE STRING PROPERTY LINE SCALE: 1/16" = 1'-0" BLUE RAVEN 1220 S. 630 E ST E, 430 AMERICAN FORK, UT 8403 800-377-4480 ',f*'AN.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORINIIATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT FIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHAT -L IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION'AFITH THE SALE AND USE OF THE RESPECTIVE EQUIPf,.,1ENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. w>_00 ui LL, 'q00't Z L 0 0 a- 65 0 0 't ( 3 ZE Cr – 00 0 1- 0 Z Z) cy) < (D < _j r— ry Lu C.0 00 CY) zoo W 0 0 CC) 11� C) LLI C) —) U) co 0 0-1 C:) d - DATE March 28, 2018 P91-JECT NtAIBER 50883544 SHEET NAME PROPERTY PLAN GE NUMBER ON PAPVL REVISI 0 C14 0 C14 W00 C:) N < N (D (D (D 0 W �= 0 0 E Q) 6) Lu L.L M Z M U) 0 uj cu C) U) LCO o 0 U) < C) DRAWING BY Eric Thomas DATE March 28, 2018 P91-JECT NtAIBER 50883544 SHEET NAME PROPERTY PLAN GE NUMBER ON PAPVL REVISI 0 w O LL O I - z LL DC SYSTEM SIZE: 3.0 kW DC ROOF TYPE: Comp Shingle (10) Trinasolar 300 TSM-DD05A.05(II) Enphase IQ6-60-2-US,----INVERTER OVERHEAD SERVICE LINE INV INVER-] ER 4 DC DISCONNECT SUB (E) SUBPANEL LC (N) LOAD CENTER AC AC DISCONNECT ❑M UTILITY METER / SERVICE PANEL JB JUNCTION BOX FCOMBINER BOX PV PV REVENUE METER FIRE SETBACK EIAT CONDUIT RUN (TO BE DETERMINED IN FIELD) PV ',,'ARE STRING PROPERTY LINE SCALE: 1/8" = 1'-0" C' BLUE RAVEN 9220 S. 630 E STE. 430 AMERICAN FORK, UT 84003 800-377-4480 V.":"J'J'(.BLU ERAVENSOLAR.00M CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION N11TH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLARLLC. }O �' X00 w w'4 Q o 't <z� O 0� 001-- rn QOM mow°? (_)0 M 0 0 00 w U U co -7 C/) O ry d Digitally signed by John Calvert Date: 2018.04.18 13:22:55 -06'00' DRAWING BY Eric Thomas DATE March 28, 2018 PROJECT Nii .IBER 50883544 -SHEET NAME SITE PLAN . PAGE NUMBER REVISION PV3 0 z N O cv Lu�- Q N 00 N O (n Cz U U N M P 1 67�� °y LL m a) En- w H U AZIMUTH:270° �`ii z U > PITCH:23° w a �c TSRF:60% ��;L� 'Q #" C/)Q e`i CD 0co _ s°o Digitally signed by John Calvert Date: 2018.04.18 13:22:55 -06'00' DRAWING BY Eric Thomas DATE March 28, 2018 PROJECT Nii .IBER 50883544 -SHEET NAME SITE PLAN . PAGE NUMBER REVISION PV3 0 PV ARRAY STRUCTURAL CRITERIA PV MODULE COUNT: 10 MODULES # OF ATTACHMENT POINTS: 18 ARRAY AREA: Module Count X 17.51 ft' = 175. 1 ft' ROOF AREA: 1651.3ft2 % OF ARRAY/ROOF: 10.6% ARRAY WEIGHT: Module Count x 501bs = 500.O1bs DISTRIBUTED LOAD: Array Weight - Array Area = 2.86 IbS/ft2 POINT LOAD: Array Weight _ Attachments = 27.8lbs/attachment ASCE 7-10 WIND SPEED: 136 MPH SITE CRITERIA GROUND SNOW LOAD: 30 PSF U EXPOSURE CATEGORY: C SEISMIC DESIGN CATEGORY: D 'rame Microrail IMRAIL Trinasolar 300 TSM-DD05A.05(11) PV MODULE (E) ROOF MEMBRANE UNIRAC SLIDERS AND TRIMRAIL ROOF ATTACHMENTS FLASHING 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE Unirac Sunfrarne Microrail Trinasolar 300 TSM-DD05A.05(11) PV MODULE (E) ROOF MEMBRANE UNIRAC SLIDERS FLASHING 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE PV Mt -Yr?! 11 F (RFHTNr) TPTM kATI ) — SAIL ARRAY DETAIL, FRONT VIEW Scale- 3/8" = 1'-0" ROOF TYPE: Comp Shingle ROOF FRAMING TYPE: Rafter Unirac S1.11-iframe Microrail FRAME RAFTER OR TOP CHORD SIZE: 2X6 RAFTER OR TOP CHORD SPACING: 24"O.C. CEILING JOIST OR BOTTOM CHORD SIZE: 2x4 CEILING JOIST OR BOTTOM CHORD SPACING: 16"O.C. SFM Raised Seal Flashing MODULE" 23' VVI DTH I V-10" 43019 1A Digitally signed by John Calvert Date: 2018.04.18 13:23:09 -06'00' BLUE RAVEN 1220 S. 630 E STE. 430 AMERICAN FORK, UT 84003 800-377-4480 V,AVW.BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN VjHOI - E OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION �,,'ITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. >_ T_ ' ; U) 0 C:) 0� D_ 00 ED LLJ ,T 0 o (-D Z T I_ Z < 0 _j QOM GE LU U') I- L—L (D z C:) (y) U) 00 000 00-1 LL] C) C) CID ---) C/) 0 cr_ n DRAWING BY Eric Thomas DATE March 28, 2018 PROJECT N,;MSER 50883544 SHEET NAMIE EQUIP. DETAIL PAGE NUMSER ON REVISI 0 CN 0 ILL W C/) aNi Cz E co F CU < Q) C) C:) M C:) OC) 0 (D cm CU N LLI U) 2i LLI C/) 0 >_ Cl) CD D M" DRAWING BY Eric Thomas DATE March 28, 2018 PROJECT N,;MSER 50883544 SHEET NAMIE EQUIP. DETAIL PAGE NUMSER ON REVISI 0 (1) 10 AW°tGTHWN-2, COPPER, BLACK: (LINE 1) 9.6 AAC (1) 10 AWG THWN-2, COPPER., RED (LINE 2) 246 V AC 15 (1) 10AV't�G THWN-2, COPPER, WHITE (NELTRAL) ,r'`� (1) 10 AWG 7HW4,N-2, COPPER, BLACK (LINE 1) MAX 9.6 AAC 4(1) 10 AWG THWN-2, COPPER, RED (LINE 2) 240 V AC / OR 10 AWG USE -2 PV WIRE, 9OC. COPPER t"-�` (1) 10-2 NM -B w/G, COPPER MAX 9.6 AAC S2 PV WIRE, 90C, COPPER 240 VAC 'y OR 10 AVJG Un - , �� (1) 12-2TC-ER,TF3wN-2, COPPER MAX 9.6 AAC j ) (1) 6 AWG BARE, COPPER (EGC) 240 V AC 1220 S. 630 E STE. 430 AMERICAN FORK, UT 84003 80D-377-4450 V00I01. BLUERAVENSOLAR.COM f (1) 10 AWG THVVN-2, COPPER., GREEN (GROUND) ---'`"f (1) 10 AWG THWN-2, COPPER, GREEN (EGC) N 00 O LLI N W 2 I— U) U) U 0 C:) co, (1) 3,;41NCHEMT CONDUIT (1) 314 INCH EMT CONDUIT BLUE RAVEN USED FOR THE BENEFIT OF 3. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND 1. ALL CONDUIT TO BE RAN AT LEAST 718" ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. N 1220 S. 630 E STE. 430 AMERICAN FORK, UT 84003 80D-377-4450 V00I01. BLUERAVENSOLAR.COM CONFIDENTIAL - THE INFORMATION 2. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN N 00 O LLI N W 2 I— U) U) U 0 C:) co, HEREIN CONTAINED SHALL NOT BE PROVIDED) IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. USED FOR THE BENEFIT OF 3. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ANYONE EXCEPT ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. B E DISC £NS D IN NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT. WITHOUT THE WRITTEN PERMISSION OF (E)100A MAIN SERVICE PANEL BLUERAVENSOLAR LLC. (E)100A / 2P MAIN BREAKER UTILITY PV ENPHASE IQ COMBINER PRODUCTION Ei METER 200A PV AC DISCONNECT X -IQ -AMI -240-2 (10) Trinasolar 300 TSM-DD05A.05(II) � O O a_ O (E)100A / 2P NON-FUSED LEVER BYPASS LOCKABLE, VISIBLE OPEN (SOLAR LOADS ONLY) JUNCTION BOX(S) ( ) UL 1703 COMPLIANT LU LU ,t O Z O METER SOCKET 30A, 240V, 2 -POLE OPTIONAL IF PV 10 En hase IQ6-60-2-US MICRO INVERTERS ( ) p 00 C) t- D WIRE USED FOR UL 1741 COMPLIANT Q M U _j � < (E)LOADS ENTIRE HOMERUN Q LCJ M N JUNCTION BOX JUNCTION BOX 10 F -- u' O M CIRCUIT OO o0 (N)20A/2P (N)20A/ P (1) OF 10 MODULES UL2 7 L, u LUU U) iz �2 G__O �z N G G - G G G rTtl_ 120/240 VAC F 60HZ TO UTILITY GRID 15 15 3 2 III G PV BREAKER TO BE LOCATED OPPOSITE END OF BUSSING FROM MAIN BREAKER (E) GROUNDING ELECTRODE INTERCONNECTION NOTES 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES, ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC 705.12(D)(3)]. 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH 3. DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO EITHER A FUSEABLE SOURCE CIRCUIT PV Production meter notes: 1. The self-contained metering will be in compliance with the most recent revision of the Xcel Energy Standard; specifically Section 4.11. 2. The PV production meter will be required to have the PV generation wired to the line side terminals (top of meter block). 3. The meter socket for the PV production meter shall be marked with a stamped brass, aluminum, or stainless steel tag, indicating the address including the unit, typically "PV PROD" in accordance with the requirements for "Meter Identification" in Section 4.14.4 of the Xcel Energy Standard. 4. The PV production meter shall be located within ten (10) feet of the existing utility meter. If there is any reason this cannot be accomplished, a site plan showing proposed equipment locations shall be submitted for review. The local meter shop must approve the site plan for application approval; site meetings can be arranged upon request. NOTE TO INSTALLER: The current Placard that we require at the utility meter and AC Disconnect is a yellow with black lettering Z N O Q (D Of O M L Z fM LLI M (n Q (D n N 00 O LLI N W 2 I— U) U) U 0 C:) co, DR.AVVING BY Eric Thomas DATE March 28, 2018 PRCJECT: NiWI:SER 50883544 SHEET TAME ELEC. 3 LINE DIAL. PAGE NUMBER REVISION PV5 1 0 MUDULL SPECII-ILA I IUNS trinasoiarjuu Ibm-uuu_-iA.U.j[It; RATED POWER (STC) 300 tit MODULE VOC 39.9 V DC MODULE VMP 32.5 V DC MODULEIMP 9.19 A DC MODULE ISC 9.64 A DC VOC CORRECTION (%I'C) -0.29 °C VMP CORRECTION (%PC) -0.39 °C SERIES FUSE RATING 20 A DC ADJ. MODULE VOC @ ASHRAE LOWTEMP 45.5 V DC ADJ. MODULE VMP @ ASH RAE 0.4% HIGH TEMP 27.1 V DC MICHOINVER1ER5PECIFIS-AIIUNS Enlatia5e]QtC-IJU-L-U5 POWER POINTTRACKING (MPPT) MINIMAX 22 - 48 V DC MAXIMUM INPUT VOLTAGE 48 V DC MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC MAXIMUM USABLE DC INPUT POWER 330 W MAXIMUM OUTPUT CURRENT 0.96 A AC AC OVERCURRENT PROTECTION 20 A MAXIMUM OUTPUT POWER 240 W CEC WEIGHTED EFFICIENCY 97% PHOTOVOLTAIC AC DISCONNECT (OUTPUT LABEL (NEC 690..54) AC OUTPUT CURRENT 9.6 A AC NOMINAL AC VOLTAGE 240 V AC DESIGN LOCATION AND TEMPERATURES TEMPERATURE DATA SOURCE ASHRAE 0.4% HIGH TEMP STATE Colorado CITY Wheat Ridge WEATHER STATION D ENV ERICENTEN N IAL ASHRAE EXTREME LOW TEMP (`C) -23 ASHRAE 0.4% HIGH TEMP @C) 36 SYSTEM ELECTRICALSPECIFICATI[ONS CIR 1 CIR 2 CIR 3 CIR4 CIR5 CIR 5 NUMBER OF MODULES: PER IVIPPT DC PLOWER RATING PER CIRCUIT (STC) TOTAL MODULE NUMBER STC RATING OF ARRAY AC CURRENT @ MAX POWER POINT (IMP) MAX. CURRENT (IMP X 1.25) OCPD CURRENT RATING PER CIRCUIT MAX. COME. ARRAY AC CURRENT (IMP) MAX. ARRAY AC POWER 10 3WO NOMINAL OPERATING AC FREQUENCY 47- 68 HZ AC MAXIMUM AC POWER 240 VA AC MAXIMUM AC CURRENT 10 MODULES 3000W DC 9.6 12 20 12 AWG m O CONDUCTOR RATING= 30 A 9.E 24GUVV AC At; FHUI UVULA I IL MUL)ULE NIAKKIFYU [NEL OtW.3 Zj NOMINAL OPERATING AC VOLTAGE 240 V AC NOMINAL OPERATING AC FREQUENCY 47- 68 HZ AC MAXIMUM AC POWER 240 VA AC MAXIMUM AC CURRENT 9.6 A AC MAXIMUM OCPD RATING PERCIRCUIT 20 A AC GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690-471 AND [NEC 250-501 THROUGH [NEC 250-601 SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.211, [NEC TABLE 250.1221, AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 9. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED. 10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO [NEC 690.451 AND BEA MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE (#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 11. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF #4 AWG OR LARGER) 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 13. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.661, DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.1661, MINIMUM #8AWG WHEN INSULATED, #6AWG WHEN EXPOSED TO DAMAGE. 14. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. CONDUCTOR SIZE CALCULATIONS MICROINVERTER T[O MAX. SHORT CIRCUIT CURRRENT (ISC) = 9.6 A DC I__O� U 0 I` JUNCTION BOX MAX. CURRENT (ISC X1.25) = 12.0 A DC z LL 0 UOM CONDUCTOR (TC -ER, (90°C))= 12 AWG m O CONDUCTOR RATING= 30 A A AMB. TEMP. AMP. CORRECTION = 0.91 % r� iso ADJUSTED AMP.= 27.3 > 12.0 JUNCTION BOX TO MAX. SHORT CIRCUIT CURRRENT (ISC) = 9.6 A DC COMBINER BOX MAX. CURRENT (ISC X1,25) = 12.0 A DC CONDUCTOR (THWN-2, (90°C) = 10 AWG CONDUCTOR RATING = 35 A CONDUIT FILL DERATE= 1 AMB. TEMP. AMP. CORRECTION = 0.51 ADJUSTEDAMP.= 31.95 > 12.0 EGC MAX. CHANNEL ISC= 12.0 A DC CONDUCTOR (THWN-2, (®C))= 10 AWG EGC CONDUCTOR RATING = 60 A CONDUIT FILL DERATE= 1 AM 13. TEMP. AMP. CORRECT] ON = 0.91 ADJUSTEDAMP.= 54.6 > 12.0 COMBINER BOX TO INVERTER RATED AMPS= 9.6 A AC MAIN PV OCPD MAX. CURRENT (RATED AMPS 1€1.25) = 12 AAC CONDUCTOR (TH1.+wdN-2, (9010) = 10 AWG CONDUCTOR RATING= 35 A CONDUIT FILL DERATE = 1 AMB. TEMP. AMP. CORRECTION = 0.91 ADJUSTEDAMP.= 31.85 > 12.0 WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS 2. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE -2, AND SINGLE -CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC -ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED 3. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.81 FOR MULTIPLE CONDUCTORS 4. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 (13)(2)(a), NEC TABLE 310.15(13)(3)(a), & NEC 310.15(B)(3)(c)] 5. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE -2, 90'C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 60OV, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES 6. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90'C RATED, WET AND UV RESISTANT, RATED FOR 600V 7.4 -WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 8. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 9. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 11. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 12. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY ' USE -2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE "' USE -2 IS AVAILABLE AS UV WHITE 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31, NEC 250.118(10). DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 14. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH NEC 230.6(4) AND SECURED NO GREATER THAN 6' APART PER NEC 330.30(6). '1111�1* BLUE RAVEN 1220 S. 630 E STE. 430 AMERICAN FORK, UT 84003 800-377-4480 VWI W. BLU ERAVENSOLAR. COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. (} o W LLI -,tO T 00 a f OZ'T < 00 I__O� U 0 I` rn Q 0 I Lu co. LO 00 z LL 0 UOM OQw U W U U) m O a- _ - A % r� iso Z N O LLCn co N 00 O N U co 0 W CO ca Q o co co CDN DRAWING BY Eric Thomas DATE March 28, 2018 PROJECT NUMBER 50883544 SHEET NAME ELEC. CALCS. PAGE NUMBER REVISIONPV6 1 0 LABEL FOR PV � NG MEANS VVHERE ALL NIN TERMINALS OF THE DISCONNECTING MEANS MAY BE ELECTRIC SHOCK HAZARD ENERGIZED IN THE OPEN POSITION. TERMINALS ON THE LINE AND [NEC 690.13(B). NEC 705.22] LOAM SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL 2 ftRECT AT EACH DC DISCONNECTING IMEANS, INCLUDING THE CURRENT DC DISCONNECT AT THE INVERTER. PHOTOVOLTAIC POMR SOURCE[NEC 690.53, NEC 690.13(6)1 I MAXIMUM VOLTAGE VDC MAX CIRCUIT CURRENT AMPS LABEL 3 # l AT POINT OF INTERCONNECTION. MARKED AT AC DISCONNECTING MEANS. A ! DISCONNECT [NEC 690.54, NEC 690.13 (B)] RATED AC OUTPUT CURRENT A NOMINAL OPERATING AC VOLTAGE V !ABEL4 AT POINT OF INTERCONNECTION FOR EQUIPMENT �(Nfl,`� CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR DUAL POWER SUPPLY SUPPLIED FORM MULTIPLE SOURCES, EACH SERVICE EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION SOURCES: UTILITY GRID AND SOURCE LOCATIONS. PV SOLAR ELECTRIC SYSTEM [NEC 705.12(8)(311 INVERTER OUTPUT CONNECTION QO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL 5 PLACED ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(D)(2)(3)(b)] LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2014 NATIONAL ELECTRIC CODE. OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.211 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3'8". WHITE ON RED BACKGROUND: REFLECTIVE AND PERMANENTLY AFFIXED [IFC 605,11.1.1] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE `OFP POSITION TO SaaR c SHUT DOWN P'! SYSTEM "'RfRs AND REDUCE SHOCK HAZARD IN THE ARRAY LABELS AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES. AND OTHER WIRING METHODS; SPACED AT MAXIMUM 1OFT SECTION OR b HERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO 4A`HICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] ALL ELEMtC POWER SOURCE DISCONNECTING MEANS GROUPED AND LABELED WITHIN 10 FT AND LINE OF SITE OF THIS LOCATION LABEL 9 SIGN LOCATED AT RAPID SHUT DOtNN DISCONNECT SWITCH [NEC 690.56(C)(3)1. 1IM--407 1W SIGN LOCATED AT MAIN SERVICE DISCONNECTING MEANS IF ALL ELECTRICAL POWER SOURCE DISCONNECTING MEANS ARE GROUPED WITHIN 1D' AND LINE OF SITE OF MAIN SERVICE DISCONNECT [NEC 690.56(B) & NEC 705.10]. A ,. THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RAT ING OF ALL OVERCURRENT DEuICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACI'TY OF BUSBAR. PHOTOVOLTAIC SYSTEM CONNECTED PV AC DISCONNECT RAPID SHUTDOWN NOT REQUIRED LABEL 10 (ONLY IF 3 OR MORE SUPPLY SOURCES TO A BUSBAR) SIGN LOCATED AT LOAD CENTER IF IT CONTAINS 3 OR MORE POWER SOURCES. [NEC 705.12(D)(2)(3)(C)] LABEL II PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. LABEL 12 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY LABEL 14 SIGN LOCATED AT AC COMBINER BOX FOR ALL MICRO -INVERTER i AC MODULE INSTALLS (IF APPLICABLE). INTEGRATED DC DISCONNECT JUNCTION BOX OR COMBINER BOX `ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. BLUE RAVEN 1220 S. 630 E STE.430 AI:IERICAN FORK, UT 84003 800-377-4480 UdLVJV. BLU ERAVEN SOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPP:1ENT, •vdITHOUT THE ':YRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. O Wz� LABEL 8 cV FOR PV SYSTEMS THAT ONLY SHUT DOVJN Willi RAPID SHUTDOWN 00 CONDUCTORS LEAVING THE ARRAY: UOQ Owe U SIGN TO BE LOCATED ON OR NO MORE TURN RAPID S14UMOWN SWITCH O THAN 3 FT AWAY FROM SERVICE TOTHE`DFFPCSITION m DISCONNECTING MEANS TO WHICH THE TO SHUT DOWN CONDUCTORS OLTSICE THE - PV SYSTEMS ARE CONNECTED AND ARRAY CONDUCTORSWITHIN 'HE ARRAY REMAIN -- -- SHALL INDICATE THE LOCATION OF ALL IDENTIFIED R, -,PID SHUTDOWN SWITCHES ENERG2ECI N SUNLIGHT m IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(Bt] ALL ELEMtC POWER SOURCE DISCONNECTING MEANS GROUPED AND LABELED WITHIN 10 FT AND LINE OF SITE OF THIS LOCATION LABEL 9 SIGN LOCATED AT RAPID SHUT DOtNN DISCONNECT SWITCH [NEC 690.56(C)(3)1. 1IM--407 1W SIGN LOCATED AT MAIN SERVICE DISCONNECTING MEANS IF ALL ELECTRICAL POWER SOURCE DISCONNECTING MEANS ARE GROUPED WITHIN 1D' AND LINE OF SITE OF MAIN SERVICE DISCONNECT [NEC 690.56(B) & NEC 705.10]. A ,. THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RAT ING OF ALL OVERCURRENT DEuICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACI'TY OF BUSBAR. PHOTOVOLTAIC SYSTEM CONNECTED PV AC DISCONNECT RAPID SHUTDOWN NOT REQUIRED LABEL 10 (ONLY IF 3 OR MORE SUPPLY SOURCES TO A BUSBAR) SIGN LOCATED AT LOAD CENTER IF IT CONTAINS 3 OR MORE POWER SOURCES. [NEC 705.12(D)(2)(3)(C)] LABEL II PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. LABEL 12 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY LABEL 14 SIGN LOCATED AT AC COMBINER BOX FOR ALL MICRO -INVERTER i AC MODULE INSTALLS (IF APPLICABLE). INTEGRATED DC DISCONNECT JUNCTION BOX OR COMBINER BOX `ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. BLUE RAVEN 1220 S. 630 E STE.430 AI:IERICAN FORK, UT 84003 800-377-4480 UdLVJV. BLU ERAVEN SOLAR.COM CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPP:1ENT, •vdITHOUT THE ':YRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. O Wz� w a- 00 0 cV Z :D Cn Q Q W c') 00 zoo UOQ Owe U W 0 U) 00 O Q_ Z cV O I— Q O z W U) N M MLL H M c Q �- (D L � 0 0 co N w 0oo N O cn U I-- � i - U) N U 0 DRAWINGS BY Eric Thomas DATE March 28, 2018 PRCJ ECT NU.'41BER 50883544 SHEET NAME LABELS PAGE NUJMgBER REVISICN PV8 0 s71c73��7�J PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING. WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY I SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC ENGRAVE IN CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAGUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC. [NEC 690.56(B)&(C)] [NEC 705.10]. 1220 S.630 E STE.430 AMERICAN FORK, UT 84003 800-377-4480 V,,,',/V V%.!,BLUER•AVENSOLAR.COt.-1 CONFIDENTIAL - I HE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT 61UERAVENSOI-AR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIP✓>ENT, VOTHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. �}o Wz4 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: z 0-)Q ,�,^^ RAPID SHUTDOWN AC VJ U O Q DISCONNECT SWITCH W U C/) MAIN DISTRIBUTION w UTILITY DISCONNECT cI AC P: O Q LL O z O of �� PV ARRAY LL co N LL 3540 Chase Street, Wheat Ridge CO 80212 s71c73��7�J PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING. WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY I SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC ENGRAVE IN CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAGUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC. [NEC 690.56(B)&(C)] [NEC 705.10]. 1220 S.630 E STE.430 AMERICAN FORK, UT 84003 800-377-4480 V,,,',/V V%.!,BLUER•AVENSOLAR.COt.-1 CONFIDENTIAL - I HE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT 61UERAVENSOI-AR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIP✓>ENT, VOTHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. �}o Wz4 Ira -00 ODd- -j z 0-)Q ,�,^^ Mr— � _ `e' g VJ U O Q E 00 O W U C/) U) U m � O ry d 00 Z N O cv u.i 00 N Q c Ali U C) C co w LL 2 I H U z ry U) 0 C 3: Lu Co ® cn Lz o C/) Q M 7RAVVING BY Eric Thomas March 28, 2018 PRO JECT NUtABER 50883544 SHEET NAME PLACARD RAGE NUMBER REVISION PV1Q 1 0 Data Shc­t Enphase Microinverters Enphase IQ 6 and I r, microinverters U�• To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 6 Micro" and Enphase IQ 6+ MicrOTM dramatically simplify the installation process while achieving the highest efficiency for module -level power electronics. Part of the Enphase IQ System, the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase IQ EnvoyT", Enphase Q Aggregator'", Enphase IQ Battery", and the Enphase Enlighten'" monitoring and analysis software. The IQ 6 and IQ 6+ Micro extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved two wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60 -cell and 72 -cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with fixed power factor, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741 -SA) ­hc IQ 6+ Micro is required to support 72 -cell modules To learn more about Enphase offerings, visit enphase.com cj 20 IS Enphase Energy. All rights reserved. Ali hade^^srks ;r hrands :ised are ,he propP.ty of 2014-J1 10 � '` SHEET NAME DATA SHEET PAGE NUMBER REVISION DS 0 SUE RAVEN Enphase IQ 6 and IQ 6+ Micreinverters 1220 S. 630 E STE, 430 AMERICAN FORK, UT 84003 INPUT DATA (DC) IQ6-60-2-US / IQ6-60.5-US IQ6PLUS-72-2-US t IQ6PLUS-72-5-US Commonly used rnom e. pairings' 195 W - 330 W + 235W -400W+ 800-377-4480 Module compatibility 60 -cell PV modules only 60 -cell and 72 -cell PV modules ti°AqW•BLUERAVENSOLAR.COM CONFIDENTIAL -THE INFORMATION Maximum input DC voltage 48V 62V Peak power tracking voltage 27 V - 37 V 27 V - 45 V HEREIN CONTAINED SHALL NOT BE Operating range 16 V - 48 V 16 V - 62' V THE USEDANOYONE EXCEPTIT OF Min/Max start voltage 22V/48V 22V/62V BLUERAVENSOLAR NOR SHALL IT Max DC short circuit current (module Isc) 15A 15A BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE Overvolta e class DC ort 9 P II II RECIPIENTS ORGANIZATION, DC port backfeed under single fault 0 A 0 A EXCEPT IN CONNEC TION WITH THE PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; SALE AND USE OF THE RESPECTIVE AC side protection requires max 20A Per branch circuit EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. OUTPUT DATA (AC) IQ 6 Microinverter IQ 6+ Microinverter Peak output power 240 VA 290 VA Maximum continuous output power 230 VA 280 VA�- O CO Nominal (L -L) voltage/range2 240 V / 211-264 V 208 V /183.229 V 240 V / 211-264 V 208 V 1183-229 V Ll_! LU 40 Q -4. Maximum continuous output current 0.96 A 1.11 A 1.17 A 1.35A O Z� 1 J U Nominal frequency64 Hz 60 Hz z Q Extended frequency range 47 - 68 Hz 47 - 68 Hz Q () z C") Power factor at rated power 1.0 1.0 Lr) i_- LLl O Maximum units per 20 A (L -L) branch circuit 16 (240 VAC) 13 (240 VAC) co Z < O M O < 00 O 14 (208 VAC) 11 (208 VAC) W Overvoltage class AC port lil 161 —) w LiJ AC port backfeed under single fault 0 A 0 A O Power factor (adjustable) 0 7 leading . 0 7 lagging 0.7 leading ... 0.7 lagging �' J m EFFICIENCY @240 V @208 V @240 V @208 V GEC we€ghted eff€ciency97.0 lh 97 0 `;> 97.0% 97.0 MECHANICAL DATA Ambient temperature range -40°C to +65°C Relative humidity range 4% to 100'% (condensing) Connector type MC4 (-2-US) or Amphenol H4 UTX (-5-US) Dimensions (WxHxD) 219 mm x 191 mm x 37.9 mm (without bracket) Weight 1.29 kg (2.84 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -Insulated r, Environmental category/ UV exposure rating NEMA Type 6 / outdoor `r o, FEATURES Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy 7 Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741 -SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES -0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at,«nphase com en-usjsLW r moct...le-g.Qmoa#. ill y. 2. Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings, visit enphase.com cj 20 IS Enphase Energy. All rights reserved. Ali hade^^srks ;r hrands :ised are ,he propP.ty of 2014-J1 10 � '` SHEET NAME DATA SHEET PAGE NUMBER REVISION DS 0 Data ihrrt Enphase Networking Enphase IQ Combineir U� LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner'" with Enphase IQ Envoy' consolidates interconnection equipment into a single enclosure and streamlines PV installations by providing a consistent, pre -wired solution for residential applications. Smart Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Simple Three pre-installed 20 A / 240 VAC circuit breakers Provides production metering and consumption monitoring. Reliable Durable NRTL-certified NEMA type 3R enclosure Five-year warranty Enphase IQ Combiner �1 1220 S.030 E 8 0 AMERICAN FORK, 84003 UT , UT 800-377-4480 VWWv.BLUERAVENSOLAR.COM MODEL NUMBER IQ Combiner X-IQ-AM1-240-B IQ Combiner with Enphase IQ Envoy" for Integrated revenue grade PV production metering CONFIDENTIAL -THE INFORMATION (ANSI C12.20+/- 0.5%) and optional consumption monitoring (+/-2.5`x). HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ACCESSORIES (order separately) Enphase Mobile Connect" Plug and play industrial grade cellular modem with five-year data plan for systems up to 60 ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT CELLMODEM-01 (3G) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, BE DISCLOSED IN WHOLE OR IN CELLMODEM-03 (4G) wherethere is adequate cellular service in the installation area.) PART TO OTHERS OUTSIDE Consumption Monitoring CT Split core current transformers enable whole home consumption metering (+{- 2,5%) RECIPIENTS ORGANIZATION, CT -200 -SPLIT EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE ELECTRICAL SPECIFICATIONS Rating w _ Continuous duty WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. Solar branch circuit breakers Three 2 -pole 20 A/240 VAC DIN rail -mounted breakers Maximum system voltage 240 VACO Rated output current 48A O � LU 0 Q < 4 input current, each input Rated 16A 121� o� U 0 r--: Maximum fuse/circuit breaker rating (output) 60A Z 7) O Q 1, U ' co Q � Z Production Metering CT 200 A solid core pre-installed on solar busbar and wired to IQ Envoy L0 I—Wo 00 Z > O O MECHANICAL DATA Dimensions (WxHxD) 38.0 x 38.7 x 20.3 cm (15.0"x 15.3" x 8.0") W Oco Weight 5.1 kg (11.2 lbs) _—) in LLJ Ambient temperature range -40° C to +46° C (401 to 115° F) O J Cooling Vented, natural convection, plus heat shield n m Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire size 14 to 6 AWG copper conductors for branch inputs. 14 to 4 AWG copper conductors for combined output. Follow local code requirements for conductor sizing. Attitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS integrated Wi-Fi 802.11b/g/n i Ethernet 802.3, Ca15E (or Cat 6) UTP Ethernet cable - not Included Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) - not included COMPLIANCE Compliance, Combiner �.T UL 1741 Compliance, IQ Envoy UL 916 CAN/CSA C22.2 No. 61010-1 47 CFR, Part 15, Class B, ICES 003 1EC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI 012.20 accuracy class 0.5 To learn more about Enphase offerings, visit enphase.com 201 E.1 - Fne�ty AI � ghts reserved Al trace ,arks nr brands Wins: rr ?r t are r ;is[ered by Yie'nesi;e nee o:: r:e . 20170420 ` SHEET NAME DATA SHEET PAGE NUMBER REVISION DS 0 Mono Multi Solutions 1211111115=011" IIIa III 1,1111 I� ATd. d m 1 a T ola r is th- c Id it t._ mg ...t,mp..:Id-r fcr solar enef ily •.ve b:eve . close cooperation with our partners s critical to stores:. Trina Solar now distributes its PV 0ioductsto over 60 countries ail over the world. Trina is ab to pians to excentiona1 service. to each customer in each market and supplornont cuinnovat've rel'abieproductswiththe Cacking r r na as 3 sTrong. h nxab'e ri r ' r a -- t nrt ed b id ig strategic, rrtut r ri ar c l t r ittn with (W," 7 ti urilwl -I . , c•ttterpa. tneis. Comprehensive Products And System Certificates tl(.Ei21,il hlAJOAA1 0 1 lllh?718 509001: Qi.raliiyR+.ana'.�n>�+':;.:err: J14001: Er vironrnental Manager. -lent System 6014064; Greenhouse gases Emissions 1e ;9caticn OHS:,•. S 1800-1: Occ'upa t on Healt h and Saf-etq Managetro..t System Maximize limited Space with top -end efficiency . Up to 1 2VV/112 power density • Low thermal coefficients for greater Energy produCt:on at high operaing temi)eratures Highly reliable due to stringent quality control _ • Over 30 in-hOUse te-sts (UV, TC, HF, and rlany Tore) • In house testing goes vu'ell beyond Certification requirements • PID resistant • 100% EL double inspection; • Selective emitter, advanced Surface texturing Certified to withstand the most challenging environmental conditions • 2a0(3 Pa',PArid load • 5�400 Pa moire load • 35 mm hail stones at 97 knl/i a. R 1 • .� ♦ 1 �:. M M j 10 Year Product Warranty • 25 Year Linear Power Warranty ............ _ 97% Adc'6i.^,r C r-,ry ........ _.......... _... r.__.._.........------ ....r._...... ------------------ r..'-_...... ■ ''i ru t.near'Plarra��t✓ S4.na<rc t, r: rvalr.:r•y � Ali "*�w FRAMED 60 -CELL MODULE BLUE RAVEN JCTS PrlWER RA'r sE ELECTRICAL DATA (STC) 1220 5.030E STE.430 TSM-DDOSA.08(Iq 280-315W AMERICAN FORK, UT 84003 TSM-DDOSA.OS(II} 275-310W Peak Power Watts-P-(Wp)* 275 280 285 290 295 300 305 310 315 Power Output Tolerance-PNax (W) 0-15 804 377-4460 V,A'00j. B L U E R AV E N S 0 LA R. C 0 M Maximum Power Voltage-vw (V) 31.4 31.7 - 31.8 32.2 325 32.6 32.9 33.1. 33.3 CONFIDENTIAL-THEINFORMATTION DIMENSIONS OFPv;MODULFimmiinrhesi Maximum Power Current-In,-n(A) 8.76 8.84 8:97 9.01 9.08 9.19 9.28 9.37 9.46 HEREIN CONTAINED SHALL NOT BE Open Circuit Voltage -Vac (V) 38.4 38.4 38.5 38.9 39.6 39.8 40.0 40.2 40.5 USED FOR THE BENEFIT OF ANYONE EXCEPT s ShortCircwtCurrent- Isr(A) 924 9.42 4.51 9.66 9:68 9.77 9.85 9.94 10.0 BLUERAVENSOLAR NOR SHALL IT Module Efficiency nm (%) 16.8 17.1 17:4 17.7 18.0 183 18.6 18.9 19.2 BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE STC Irradiance l000w/m',Cell Temperature Z5°G Air Mass.AMl.5. RECIPIENTS ORGANIZATION, ro use -Measuring tolerance, x3%. EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE o ELECTRICAL DATA (NOCT} EQUIPMENT,V;/ITHOUT THE WRITTEN PERMISSION OF a A A a Maximum Power-Pw (Wri) 205 209 212 216 220 223 227 231 235 BLUERAVENSCLAR LLC. Maximum Power Voltage-Vr (V) 29.1 29A 29.5 29.9 30.1 30.2 30.5 30:7 30.9 T_ O Cif W Maximum Power Current -Ir �o(A) 7.04 7.10 7.21 7.24 7.30 7.38 7.46 7.53 7.60 w � O 00 Nrn°"1pHi1e s�<r Open Circuit Voltage -V.- 35.7 35.7 35.8 36.2 36.8 370 372 37.4 376 Ur Z Q Q Short Circuit Current-Isc(A) T46 7.61 7.68 7.80 7.82 7.89 7.95 8.03 8.10 z D Q (n NOCT: Irradiance at BOOW/ma, Ambient Temperature 20°C Wind Speedlm/s if12z M I- W 0 LQ Z 0 - �{ MECHANICAL.DATA M 00 Q 35/1.38 992/39.1 /�, 0 U " Of Solar Cells Monocrystalline 156.75 x 156.75 mm (6 inches) W lJ Back View ) (n W Cell Orientation 60 cells (6 x 10) O D -11/0.43 ' "' Module Dimensions 1650 x 992 x 35 mm (6S.0 x 39.1 x 1.38 inches) m _ Weight 18.6 kg (41.0 lb) va Glass 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass m Backsheet White [01305A.08(II)1; Black[DDO5A.05(II)] 3snaa Frame Black Anodized Aluminium Alloy [OD05A.06(II), DDOSA.OS(II)] (A -A) ]-Box IP 67 or IP 68 rated Cables Photovoltaic Technology Cable 4.Omma (0.006 inchese), 1000 mm (39.4 inches) !-;+r:t)�(VF"s OF Fll !tA01i17 E73GSl".') Connector TrinaTS4 Fire Type Type 1 or Type 2 TEMPERATURERATINGS MAXIMUM RATINGS ;y NOQi\vr,dr,.!or"ranr,rPn el 44-C(+2'C) Operational Temperature -40-+85°C m voltase(y) Temperature Coefficientof Prix -0.39°/%/°C Maximum System Voltage 1000V DC (11C) Temperature Coefficient of Vo_ - 0.29%/°C 1000V DC (UL) R-Vt:UR•di:S OFFv;.fiO*,u.=: sir) Temperature Coefficient of 1, 005%!°C Max Series Fuse Rating 15A(Power I285W) 3:0 20A (Power )_29OW) (OO NOT connect Fuse in Combiner Box with two or more strings in parallelconnection) n 'xso 1 WARRANTY PACKAGING CONFIGURATION t 10 year Product Workmanship Warranty Modules perbox. 30 pieces 1. �v°Ita9eim" ao 25year Linear Power Warranty Modules per 40'container:840pieces (Please refer to product warrantyfor details) f`"�4`E/'''�1 t�'111Y` CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Tr�na..iW 011 ©2017 Trina So lar Linited.AIIrightsreseryed.SpecificationsincludeJInthisdatasheetare subject to change without notl ce. SHEET NAME Version number: TSM_EN_2018_A www.trinasolar.com DATA n SHCCT . GE NUMBER REVISION . FL.As!A'D FV ROOFMOUNT COMD[NER/ENCLOSURE Basic Features • Stamped Seamless Construction • 18 Gauge Galvanized Steel • Powder Coated Surfaces • Flashes into the roof deck • 3 Roof deck knockouts .5", .75", 1 " • 5 Centering dimples for entry/exit fittings or conduit • 2 Position Ground lug installed • Mounting Hardware Included **Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP 110C for fuse holders, 600V 50 AMP 90C for rail mounted terminal blocks and 600 V 175 AMP 90C for Power Distribution Blocks. Use Copper Wire Conductors. SolaDeck Model SD 0783 SolaDeck UL50 Type 3R Enclosures Available Models.- Model odels:Model SD 0783 - (3" fixed Din Rail) Model SD 0786 - (6" slotted Din Rail) SolaDeck UL 1741 Combiner/Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated - 60OVDC, 120AMPS Model SD 0783-41 3" Fixed Din Rail fastened using Norlock System **Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP 1- Power Distribution Block 60OVDC 175AMP 1- Bus Bar with UL lug Model SD 0786-41 6" Slotted Din Rail fastened using steel studs **Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug Cover is trimmed to allow conduit or fittings, base is center dimpled for fitting locations. Model SD 0783-41, wired with Model SD 0786-41, wired with Din Rail mounted fuse holders, Din Rail mounted fuse holders, bus bar and power distribution terminal blocks and bus bars. block. RS TC Enterprises, Inc . 2219 Heimstead Road . Eau Cliare, WI 54703 For product information call 1(866) 367-7782 BLUE RAVEJ 1220 S. 630 E STE. 430 A€4ERIC.AN FORK, UT 84003 800-377-4480 V:^WIv BLUE RAVE NSOLAR. COM CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION''AFITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. O W O (DZ 't Z Q 00 U O~ co W U _-) U) O .ry O Q � OJ't �O� U �C/)ZC? Lu 0 Z > O O < °O U W J m SHEET NAME DATA SHEET . GE NUMBER REVISIGN . DS O an U N I RAC Now DLARh�iuUNT No � ' 1 • � CONCEALED UNIVERSAL CLAMPS BETTER DESIGNS TRUST THE INDUSTRY'S BEST DESIGN TOOL Start the design process tot every project in am U Builder ou line design tool, ti's a great way to save time and money. BETI TER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modeles flash to the roof on steel) aftched fauls 011p,1111 a lajge valltOv of modules in Portrait at LatidsGait,,, Tilt the system no on flat tit low slow iows and dark linishestooplimitoYnn du,,-ign finaucidIs and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB lost Lfabac to hot[) liou iniijimue bulli systauu and labor casts from the, time tim job i� quoted to thetime yom teams get off the roof, Faster installs. Less Waste. Moic Profits. OUNIRAC BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM 25 PicifessaInal suppoul ftu professional installers and designers. You have access to our technical support and Raining groups Whatevatt your support needs. vieve got OPTIONAL YIAR� you covered. Visit for more information. FRONTTRIM FURIM11M WARRANTY Ul BONDING & GROUNDING f— MFGHANICAL I UL2703 0 ADING Lo J SYSTEM FIRE CLOASSIFfI,ATION CONCEALED UNIVERSAL ENDCLAMPS UNIVERSAL SELF STANDING MIOCLAMPS -41100i "M ARY NEW ENDCLAMPS RAMABLE and included End Caps WARRANTY THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING 11. 111.W,011111. "..0" W111111 BEST INSTALLATION EXPERIENCE* CURB APPEAL e COMPLETE SOLUTION 9 UNIRAC SUPPORT ENO CAPS INCLUDED WITH EVERY ENDCLAMP U -BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY I humc s technical support team is dedicated to answering Unijac is the only 11V mounting vendor with ISO cedificalarris Dont leave year project to ahanra. Untac has the financial qimstioms & addressing issues in real time. An online for 9001:2008. 14UOI=1Nll and OISAS 18001:2007, stivogth to back, our products and uAtice your risk Hzc library of documents including engInecting reports. which means vip deliver The highest standards for fit. peace of mind knowing you are providing pieducts of stamped letters and locluritall data sheets gleally firaft and function. These ceilificatious derfloir3ifate our exceptional quality. SOLARMOUNT is covered by a 25 year simplifies your Polar ft'ifig and project planning process exceflence and comm rtment to first class business ptactices, limited famduct warranty and a 5 year limited finish vIarranty ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHA10 SUN Eno FRAME an S F M MICRORAILTM SYSTEM BONDING &GROUNDING M INSTALLATION GUIDE 'I PAGE ------------------------------------------------------------------------------ ----------- ... . .. .... . con .9 .......... E� f0m -0 TL__ L -- L -1 1 1 1 T L _ --- --- I F 1 11 -1- -- 1 _'F ---- T --- - - ----- - f -1— sta", V�aiherls Single ij�c TERMINALTORQUE, Install Conductor and torque to the followir 4.6 AWG: 35in-lbs 8 AWG: 25 in -Lbs 10-14 AWG.- 20 in -lbs TERMINAL TORQUt ' ' Install Conductor and torque to the following- 4-14AWG: 35in-tbs Single U, "'y TERMINALTORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs LUG DETAIL & TO-,,,RQUyr_- INFO LUG DE TAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Rsco Lay -in Lug (GBL-4DBT) ILsco Flange Lug(SGB-4) WiLeyWEEBLug (6.7) 0 10-32 mounting hardware 0 1/4" mounting hardware 0 1/4" mounting hardware 9 Torque = 5 ft -lb 0 Torque = 75 in -Lb 0 Torque = 10 ft -Lb 0 AWG 4 -14 -Solid or Stranded 0 AWG 4 -14 -Solid or Stranded 0 AWG 6 -14 -Solid or Stranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION E -W BONDING PATH: E -W module to module bonding is accomplished with 2 pre-installed bonding clips which engage on the secure side of the MicroraiLTm and splice. N -S BONDING PATH: N -S system bonding is accomplished through a N -S bonding clip. Insert each end of the N -S bonding clip onto a module frame flange. Systern is bonded a sir array edg,, "I-vvever it is recommend, "CIA N -S bonding clips installed on both edge,!,- ',)r ease of maintenance (see also: Maintenar­'-"_� Pa �;­ _51 System bonding is accomplished through modules. System grounding accomplished by attaching a ground Lug to any module at a Location on the module specified by the module manufacturer. BLUE RAVEN 1220 S. 630 E STE. 430 AMERICAN FORK, UT 84003 800-377-4480 V:'.,'MI.BLUEF'.AVENSOLAR.COt%4 CONFIDENTIAL -THE INFORNIATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE 1/VRITTEN PERMISSION OF BLUERAVENSOLAR LLC. W W4 W W (D 0 < 00 (D Z It < _j I-- U) Z D 0-) < `tet < ti of z Lr) 00 W CD Z > 0 CY) 0 0 < 00 (-) Of LLI () —) U) LLI 0 D (x IL _j co SHEET NAME DATA SHEET PAGE NUMBER REVISION AUTHORIZATION TO MARK BLUE RAVEN This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) ` Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. 1220 S. 630 E STE. 430 AMERICAN FORK, UT 84003 800-377-4480 VAIAN. B L U E RAV E N S 0 LA R. C 0 M CONFIDENTIAL -THE INFORMATION This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be HERE INCONTAINED SHALL NOT BE applied only at the location of the Party Authorized To Apply Mark. USED FOR THE BENEFIT of PUB2017FEB16 ANYONEEXCEFT Unirac BLUERAVENSOLAR NOR SHALL IT Unirac SFM BE DISCLOSED IN WHOLE OR IN Applicant: Unirac, Inc Manufacturer: Jiaxing Pacific Energy Equipment Corp. PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION V•JITH THE No. 8 Haiwan Ave SALE AND USE OF THE RESPECTIVE 1411 Broadway Blvd NE Hangzhou Bay Bdao New Area EQUIPMENT, Y.1ITHOUTTHE Address: Address: Albuquerque, NM 87102 Haiyan Economic Development Area "A'RITTEN PERMISSION OF BLUERAVENSOLAR LLC. Jiaxing City, Zhejiang Province Country: USA Country: ChinaW} w o W Q 00 Contact: Klaus Nicolaedis Contact: Lili Zeng OT J O Z ti Jason Mayfield George Huang oho U O Z D M Q r- 505-462-2190 505-462-2190 510-979-1920 Q O 'T lY z c? Phone: Phone: 505-400-2949 650-799-7627 Z > o coo FAX: NA FAX: NA F— O coO Q 00 lY W klaus.nicolaedis@unirac.com Izeng@ccmfg.com U U U) W Email: Email: jasonm@unirac.com george@ccmfg.com O :D J Party Authorized To Apply Mark: Same as Manufacturer m Report Issuing Office: Lake Forest, CA Control Number: 5003278 Authorized by: for Dean Davidson, Certification Manager us<rffiTEd Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number This Authorization to Mark isfor the exclusive use of Imertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, otherthanto the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this.Authorization to Mark Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to 10 ark. Any further use of the Intertek narna for the sale or advertisement of the tested material, product or servir.e must first be approved in +Aaiting by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2 -Mar -2017 ED 15.3.15 (1 -Jul -16) Mandatory SHEET NAME DATA SHEET PAGE NUMBER R: -VISION DS UL 2703 Issued: 2015/01/28 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, Standard(s): and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels Photovoltaic Mounting System, Sun Frame Micro Rail- Installed Using Unirac Installation Manual, Rev Product: PUB2017FEB16 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2 -Mar -2017 ED 15.3.15 (1 -Jul -16) Mandatory SHEET NAME DATA SHEET PAGE NUMBER R: -VISION DS A i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: -�5 S­�/� % C !/�� ;� S /� Permit Number: "Z � �` 0 3.3 o ❑ No one available for inspection: Time AM/PM } Re -Inspection required: Yes rrNo../ When corrections have been made, call for re -inspection at 303-2� 34-5933 Date: f Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE -.A Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: JobAddress: Permit Number: 2 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes f No-., When corrections have been made, call for re -inspection at 303-234-5933 i Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge J� Residential Roofing PERMIT - 201703309 PERMIT NO: 201703309 ISSUED: 07/05/2017 JOB ADDRESS: 3540 Chase ST EXPIRES: 07/05/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles, drip edge, ice shield with 17 sq. ***REVISION***ADD REDECKING 7/16 PLYWOOD NEW DECKING** 1600 SQ FT $2576.00 *** CONTACTS *** OWNER (720)532-7357 TALAMANTEZ ANNA M SUB (303)582-4252 Julio Blanco/Eduardo Vasquez 160145 Highline Roofing & Gutters Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11,556.00 FEES Total Valuation 0.00 Use Tax 242.68 PAID Permit Fee 236.00 ** TOTAL ** 478.68 -- *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Roofing PERMIT - 201703309 201703309 ISSUED: 07/05/2017 3540 Chase ST EXPIRES: 07/05/2018 Residential Re—roof to install asphalt shingles, drip edge, ice shield with 17 sq. ***REVISION***ADD REDECKING 7/16 PLYWOOD NEW DECKING** 1600 SQ FT $2576.00 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that t am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed Ind that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuanc or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applica c or any ordinance or re ula 'on of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Midge COMMUNITY DEVELOPMENT Building & Inspection Services Division �' 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(a)ci.wheatridge.co.us FOR OFFICE U E ONLY Date: Plan/Permit # Vl �J Plan Review Fee' j �n (/ (/,// Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: -� l'? /Y S F 3r Property Owner (please print): 41t1oU 4 4- ju,-L,Z Phone: ?,,9 0 :53 3S Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Arch itect/E ng 1 neer: Architect/Engineer E-mail: Contractor: L, Q I-//C/� Y Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: ;;2,;2 Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) A-) J � /� 50 F r Sq. Ft./LF ( i (0 V Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) S �� OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): &U-�L) -2 / 2Uf/Z_ DATE: 1 ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS. Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of Wheat Ridge Residential Roofing PERMIT - 201703309 PERMIT NO: 201703309 ISSUED: 07/05/2017 JOB ADDRESS: 3540 Chase ST EXPIRES: 07/05/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles, drip edge, ice shield with 17 sq. *** CONTACTS *** OWNER (720)532-7357 TALAMANTEZ ANNA M SUB (303)582-4252 Julio Blanco/Eduardo Vasquez 160145 Highline Roofing & Gutters Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,980.00 ' FEES Total Valuation 0.00 PA Use Tax 188.58 Permit Fee 188.45 ** TOTAL ** 377.03 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201703309 PERMIT NO: 201703309 ISSUED: 07/05/2017 JOB ADDRESS: 3540 Chase ST EXPIRES: 07/05/2018 JOB DESCRIPTION: Residential Re—roof to install asphalt shingles, drip edge, ice shield with 17 sq. i, by m si I' 'ure' do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable wilding codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this pennit and perform the wor►c described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as pames to the work to be performed and that al( work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. I Signature of OWNER or CONTRACTOR (Circle one) Date 1. This pen -nit was issued based on the information provided in the permit application and accompanying dans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This. pen -nit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Budding Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Budding Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable»eetrte-,pr any ordinance or regulation of this jurisdiction. Approval of work is subject to Held inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ei.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Kimberly Cook From: no-reply@ci.wheatridge.co.us Sent: Friday, June 23, 2017 4:00 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 3540 Chase St. Wheat Ridge, CO 80212 Property Owner Name Anna Talamantez Property Owner Phone 7205327357 Number Property Owner Email Field not completed. Address $ -��;77. c-9 Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Eduardo Vazquez Contractor's License 160145 Number (for the City of Wheat Ridge) Contractor Phone 7202246866 Number Contractor Email Address highlineroof@gmail.com Retype Contractor Email highlineroof@gmail.com Address DESCRIPTION OF WORK Are you re -decking the Yes roof? Description of Roofing Tear off comp. shingles. Prime and paint patio roofing. Drip Material edge and ice shield. Remove corrugated fiberglass roofing. Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 17 material selected above? / Does any portion of the No V property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES of all 17 X/ roofing material for this project 2 Provide additional detail 4/12 here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contra $8,980.00 value or cost of ALL materials and labor) (:: SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Eduardo Vazquez Email not displaying correctly? View it in your browser. Line Item Total 8,720.65 Material Sates Tax 257.99 Replacement Cost Value $8,978,64 Less Depreciation (630.90) Actual Cash Value $8,347.74 Less Deductible (1,500.00) Net Claim $6,847.74 Total Recoverable Depreciation 630.90 Net Claim It Depreciation is Recovered $7,478.64 Grand Total bid amount: $7,478.64 1St check, (Highline Roofing & Gutters Inc.) Day work start: $6,847.74 When work is completed and Wheat ridge has a final sign off on permit. Highline Roofing & Gutters Inc., to assist homeowner on collecting depreciation check $630.90 2nd check made out to (Highline Roofing & Gutters Inc.) $630.90 Homeowner to pay $0.00 towards there deductible. i SIDING Description 18. R&R Siding - steel (29 gauge) . 19. R&R House wrap (air/moisture barrier) 20. Prime & paint metal siding 21. R&R -Clothes dryer vent cover 22. Prime & paint dryer vent* 23. R&R Attic vent - gable end - metal -12" x 18" 24. Seal & paint gable vent* 25. R&R Fascia - vinyl coated aluminum - 4" to 6" 26. Prime $c paint exterior fascia - metal, 4"- 6" wide Sttbtota il:: $ 99fi.26 f Total: $8,347.74 - FOR OFFICE USE ONLY City o Da : Wh6atf�k COMMUNITY DEVELOPMENT plen1permit # rt Building & Inspection Services Division 7500 WV 2e Ave., Wheat Ridge,`CO 80033 Plan Review Office: 303-235-2855 * Pax: 303-237-8929 Inspection Line: 303-234-5933 rnell: ernaits ci. +heetrici e.co us Building lig t Please cornplete s1t highlighted areas on both sides of this form. Incomplete appliostlotis may not be processed. Property Address: 3)'SyC) Property Owner (please print): Ct Phan : PropOwner Email: Mailing Address: (if different than property address) Address: City, State, i rchit+ec iii rE-mail: Phone: Contractor: O&Vv '(\�Q_ . . ...... .. G Contractors City License m Phone: L- ° 2 8 � ContractorE-mail Address: � r � � � � � � Sub Contractors: Electricak Plumbing: Mechanical: W.R. City License # WA City License # W.k City License # Other City Licensed Seib; Other City Licensed Sub: City License #r City License Complete all information on BOTH sides oft is for � " *' "" � # • ' "' 11 it e._ wmM amount OT matenais ` to use etc. Btu's Gallons