Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4763-4773 Everett Court
City of Wheat Ridge ®/ Residential Roofing PERMIT - 201800924 t PERMIT NO: 201800924 ISSUED: 04/04/2018 JOB ADDRESS: 4763 Everett CT EXPIRES: 04/04/2019 JOB DESCRIPTION: Residential reroof permit remove and install Certainteed Presidential Shake Asphalt Shingles with 31 squares. Pitch 4/12. **Duplex 4763 and 4773 Everett Ct.** *** CONTACTS *** OWNER (303)420-1595 HONAS CAROL JEAN SUB (720)838-7777 Thomas Steffan 170115 Roof Pro, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 21,180.30 FEES Total Valuation 0.00 Use Tax 444.79 Permit Fee 394.50 ** TOTAL ** 839.29 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201800924 �q PERMIT NO: 201800924 ISSUED: 04/04/2018 JOB ADDRESS: 4763 Everett CT EXPIRES: 04/04/2019 JOB DESCRIPTION: Residential reroof permit remove and install Certainteed Presidential Shake Asphalt Shingles with 31 squares. Pitch 4/12. **Duplex 4763 and 4773 Everett Ct.** I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner,9fAhe.pr0VZV and am authorized to obtain this permit and perform the work described and approved in conjunction with this erm�t. -I for tfier attest that I a legally authorized to�nclude all entities named within this document as parties to the work to be performed and th t all work to be p rfor i disclosed in this document and/or its' accompanying approved plans and specifications. -�---- /_--! Signature of=-f71R or CONTRACTOR ( a�ne) Date 1. This permit was issued based on the informa ion prothe permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of ne more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original pennit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or grantinglof a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applic�code or any Ir finance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chienuilding Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Laaenia Reimer ac-" / T o o > �/ From: no-reply@ci.wheatridge.co.us Sent: Tuesday, April 3, 2018 2:55 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling unittg' Duplex are on the property? PROPERTY INFORMATION Property Address 4763 EVERETT CT Property Owner Name CAROL HONAS Property Owner Phone 303-420-1595 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Field not completed. Yes C Honas Agreement.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Roof Pro, Inc. 170115 720-838-7777 10940 S Parker Rd #316, Parker, CO, 80134 Contractor Email Address joey@coloradoroofpro.com Retype Contractor Email joey@coloradoroofpro.com Address DESCRIPTION OF WORK TOTAL SQUARES of 31 squares the entire scope of work: — Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or 21180.30 No Pitched roof (2:12 pitch or greater) z both? (check all that apply) What is the specific pitch 4/12 of the PITCHED roof? How many squares are 31' part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) Certainteed Presidential Shake shingles V Asphalt duplex roof, 1 story SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal 3 owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisomnent, or both. Name of Applicant Thomas Steffan Email not displaying correctly? View it in your browser. www.coloradoroofpro.com k 10940 S Parker Rd #316 Liscensed& Insured Parker, CO 80134 Phone: (720)-838-7777 ,�,C.7►.l �'�'"!�� lam► _.�� r- BBB a colorado company PROPOSAL SUBMITTED TO:I C QA (b� 4h na S 1 11 DAT- DATE: i4 ",? _ (9-1 ADDRESS: CITY: n ZIP.866 n -e _ Shingle Manufacturer Brand Color Gutters Size Color REMOVE .A.1.1 ...... LAYERS OF ROOF DOWN TO THE .... OeC* ......... Notes: 2. INSTALL D/L STYLE DRIP EDGE COLOR._..'_........ ............. .. ->'yA+Aq0_ W4� 3. APPLY: () 15Lb. () 30Lb. OIL BASE FELT PAPER. -sl C 4. NAIL SHINGLE USING 6: () 1 -/4" �kl GALVANIZED NAILS. 5. W-VALLEY)tCLOSED VALLEY () 6. DOUBLE SEAL ALL SIDEWNLL FLASHINGS. 7. RE -FLASH CHIMNEY XSTEP ( ) COUNTERFLASH or O RE -SEAL 00 8. INSTALL ICE & WATER SHIELD @ EAVES AND VALLEYS O 9. RE -SEAL SKYLIGHT () ....................RE -FLASH SKYLIGHT O �101 rkO. REPLACE ANY ROTTED DECKING @ $ ... 9.6.)'r ..... ,IQ L REPLACE ALL PLUMBING PIPE FLASHINGS � 12. PAINT ALL PIPES AND FLASHIGNS ON ROOF TO MATCH. 1 3 INSTALL LOW PROFILE (Sd' NEW AIR HAWKS O 14. INSTALL NEW RIDGE VENT. ....... _ ..... ........ LF hd 15, SWEEP YARD WITH MAGNET FOR NAILS. )<I& ROOF PRO, INC'S-.6�41pu . . .... YEARS LABOR WARRANTY. XI T ALL WORK TO COMPLY WITH STATE AND LOCAL BUILDING CODES. WE PROPOSE hereby to furnish material and labor - complete in accordance with specifications below, for the swim of: V 11-)Aq0Sft$fAQ� "'\-An "-V\ Dye :�LAJ&\6 (V 0A 2e DOLLARS (S 21 U PAVMENT TERMS - , _r A C:_1 r12: jg�� First Draft Down BALANCE DUE upon COMPLETION RoofPro Inc. SUPPLEMENTS OR OVERHEAD AND PROFIT ALLOWED BY THE INSURANCE CO. WILL BE ADDED TO THE PRICE OF THIS CONTRACT AND PAID UPON COMPLETION OF THE WORK LISTED BELOW ROOFPRO, INC WILL PROVIDE PERMITS FOR ALL SERVICES PROVIDED. This Proposal Becomes Legal and Binding 72 Hours Fr ce ?m Date Of Ac�e 'ptan Roof Pro ln�' OWNER( DATE_ DATE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3/0 fm' z1o3 FE - Job Address: �� 7&-3 l�c'ira C Permit Number: t1 p/(50 �L 7LI % ❑ No one available for inspectionTime(Jj /' / AM/PM Re -Inspection required: Yes o J When correcfons have been made, call for re -inspection at 303-234-5933 Date: �� Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Electric PERMIT - 201802747 PERMIT NO: 201802747 ISSUED: 10/15/2018 JOB ADDRESS: 4763 Everett Ct EXPIRES: 10/15/2019 JOB DESCRIPTION: Residential electric -200 AMP ugrade. *** CONTACTS *** OWNER (303)420-1595 VAN ESSEN SETH *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,500.00 FEES Total Valuation 0.00 Use Tax 52.50 Permit Fee 93.35 ** TOTAL ** 145.85 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2017 NEC. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized bthe legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thyis ermrt.. I further attest that I am le ally authorized to include alt entities named within this document as parties to the work to be '- or ed an� th�t all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWN. R I or CONTRACTOR (Circle one) Date I. This permit was i d based on the information provided in the permit application and accompanyingplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Div 'an. 6. Th is . �'anc or gra g of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any a able de or r i ace or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat R dge COMMUNITY DLVLLOPMLN I Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: A, PlanlPermit # Plan Review Fee. Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** ��Property Address:q'7(*' rl U Owner Property Owner Emai Mailing Address: (if different than property address) Address: �v City, State, Zip:\ �(`Q� 0� �Q � Architect/Engineer: Architect/Engineer E-mail: Phone: Contractors City License M Phone: Phone:."�l 1 f�� `� c� a / Contractor E-mail Address: l n3c) k, ciQ ; ( ) Sub Contractors: Electrical'. I`CI' Plumbing: Mechanical: W.R. City License # lc ' -t 6 W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form -7 q(51 Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ,ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) aC� �m��e"�c� Sq. Ft./LF Amps Btu's Gallons Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume fiill responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZEDREPRES ) of (OWNER] (CONTRACTOR) PRINT NAME: G �BJP✓- `� SIGNATURE / ' DATE: Xy DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑Not Required Building Division Valuation: $ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 o 6- hl 1 d%0 `j' Job Address: 4763 ��Iole-f+ C4, Permit Number: 2010000? y IT I'd roof .41 orgy) L-/0 ❑ No one available for inspection: Time l Z SO AM/J M Re -Inspection required: Yes o When corrections have been made, call for re -inspection at 303 -234 - Date: "1 /V 10 Inspector: hcoe C0�r DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:' .� Job Address: -� Permit Number: ❑ No one available for inspection: Til Re -Inspection required: Yeses When corrections have been m °de, call* or re -ins ec� tion at 303-234-5933 Dat (0Ins ecto DO NOT THIS NOTICE s City of Wheat Ridge Residential Solar PERMIT - 201900647 PERMIT NO: 201900647 ISSUED: 05/28/2019 JOB ADDRESS: 4773 Everett Ct EXPIRES: 05/27/2020 JOB DESCRIPTION: Install a 4.480 KW grid tied, roof flush mount PV system; 16 panels, no structural required *** CONTACTS *** OWNER (720)251-3583 FREE JONATHAN & JESSICA SUB (720)255-7342 MARK MONTOYA 190076 FREEDOM FOREVER COLORADO LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,310.00 FEES Total Valuation 0.00 Residential Solar. 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by, the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that alork10 be performed is disclosed in this document and/or its' accompanying approved plans and specifications. 51z Signature of OWNER o CONTRACTOR Wircle one) Date 1. This permit was issued ba n ormation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Buildi/9 Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ` �``City of W11e t � d Cc��un�UNiTy DEVEt.c���?�•��NT Building & Inspection Services 7500 W. 291' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permitsaci.wheatridge.co.us toc FOR OFFICE USE ONLY Date: � 10 1 Plan/Permit # a0l � Aq1 Plan Review Fee: 5 -DO b'b Building Permit Application ** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address 4773 Everett Ct, Wheat Ridge, CO 80033 Property Owner (please print): Free, Jonathan & Jessica Phone: (720) 251-3583 Property Owner EmailYree112292@gmail.com Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: 4773 Everett Ct Wheat Ridge, CO 80033 City, State, zip: Wheat Ridge, CO 80033 Arch itect/Engineer. Architect/Engineer E-mail: Contractor Name: Freedom Forever Colorado, LLC City of Wheat Ridge License #: 190076 Phone: Phone: 720-936-9460 Contractor E-mail Address: jburks@freedomforever.com For Plan Review Questions & Comments (please print): CONTACT NAME (please printf: Jeremy Burks Phone: 720-936-9460 CONTACT EMAIL(please print): jburks@freedomforever.com Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form) Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. ❑COMMERCIAL RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Install a 4.480 kW grid tied, roof flush mount solar photovoltaic system. Sq. FULF Amps Squares BTUs Gallons For Solar: 4.480 Kw 16 # of Panels E Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $18,310.00 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application: that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE EINE (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): Digitally signed by Jeremy Burks Jeremy Burks ate.2019.04.0915:31:32 DATE: 4/9/19 Printed Natne: Jeremy Burks DEPARTMENT USE ONLY ZONING COMMMENTS: Reviewer: BUILDI EPAART�COWME+ff5�.. Revie er: G_f_ PUBLIC WORKS COMMENTS: Reviewer: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: Kimberly Cook From: Kimberly Cook Sent: Thursday, April 18, 2019 7:49 AM To: jburks@freedomforever.com' Cc: 'Jim Widlar' Subject: 4773 Everett Court Attachments: 2012 Residential PV Solar Installation.pdf Importance: High Hi Jeremy, Please see comments below from our Plan Reviewer, Jim Widlar— The above mentioned plan review is not approved for the following reasons: (1) A Colorado Professional engineer seal is required on all systems that exceed 10KW (2) Project should comply with the 2017 National Electrical Code. (3) A Colorado Licensed engineer must preformed calculations that the structure can support the designed loads. (4) Conform with all requirements of the City of Wheat Ridge PV Solar Checklist. Please see attached checklist for PV installations. Thanks, Kim Cook Permit Technician 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2876 Fax: 303-237-8929 www.ci.wheatridge.co.us jo, of WheatPjC1L7e l ON oll W he;alt iC,Ige '()MXUJN1#Y [)] %,'I S4 WN11 % I CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. McPherson Engineering Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Free Residence 4773 EVERETT CT Wheat Ridge, CO 80033 Digitally sealed by RJM on 5/9/19 Designed in Accordance with IBC 2012, ASCE 7-10, NDS 2012 Date: 5/9/19 Job #: S19-1393 E.O.R.: Ryan McPherson, P.E. 6169 Sunny Circle Mira Loma, CA 91752 Mobile: (909) 569-2244 Email: rya n@mcpherson.engineering met MM'S R1dO 1of7 5/9/2019 2:16 PM ©McPherson Engineering McPherson Engineering Table Of Contents By: M.N.C. Date: 5/9/19 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 2of7 5/9/2019 2:16 PM ©McPherson Engineering -PE Location: 4773 EVERETT CT Wheat Ridge, CO 80033 Existing Structure Info: McPherson Engineering Number of Stories = 1 Aroof = 1400 sq. ft. A3rd_fir = 0 sq. ft. A2nd_f r = 0 sq. ft. Site Properties: Lattitude = 39.783189 Longitude = -105.097191 Ss = 0.190 S, = 0.060 Exposure Category = C Wind Speed = 130 m.p.h. P.V. Array Info: Project Info By: M.N.C. Date: 5/9/19 Roof Square Footage Third Floor Square Footage (if applicable) Second Floor Square Footage (above basement level garage) Model = Q -PEAK G4.1 Height of Panel = 65.70 in. Width of Panel = 39.40 in. Area of Panel = 18.0 ft.2 Number of Panels = 13 Total Area of Array = 233.7 ft.2 Spacing of Anchors = 6.0 ft. max. on center rows of racks per panel = 2 Panel Tilt = 7-27 deg Snow Load: Ps = 30 p.s.f. snow load per AHJ Ct = 1.1 thermal factor Ce = 1.0 exposure factor C5_E = 1.0 slope factor w/out solar (not slippery) C5_N = 0.9 slope factor with solar (slippery) I = 1.0 importance factor SLE = 33 p.s.f. existing snow load on roof SLN = 30 p.s.f. minimum snow load per AHJ. CHY of Wheat 1096 V1161n9 CAVsion 3of7 5/9/2019 2:16 PM ©McPherson Engineering E � McPherson Engineering By: M.N.C. Date: 5/9/19 Existing Loads: Roof Design Loads: 10.0 p.s.f. Roofing = 4.0 p.s.f. Sheathing = 1.5 p.s.f. Framing = 1.5 p.s.f. Misc = 1.0 p.s.f. DLrj = 8.0 p.s.f. Ceiling = 2.0 p.s.f. DLr2 = 10.0 p.s.f. SLE = 33.0 p.s.f. LLr = 20.0 p.s.f. Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f. Sheathing = 2.2 p.s.f. Framing = 2.0 p.s.f. Interior Partitions = 15.0 p.s.f. Ceiling = 5.0 p.s.f. Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f. Proposed Loads: Gravity Loads Composition roofing 1/2" Plywood 2x Rafter/Truss Framing Roofing Dead Load (applied to top of rafters/trusses only) Drywall and 2x framing Total Existing Roof Dead Load Snow load (existing) Roof Live Load (Per C.B.C, Table 1607.1) Weight of floor finish 3/4" plywood 2x framing or manufactured floor truss 2x framed walls with drywall finish each side Drywall ceiling finish below Total Existing Floor Dead Load Panels = 2.8 p.s.f. weight of panels including rack system DLrl_proposed - 10.8 p.s.f. Proposed Roof Dead Load (applied to top only) DLr2_proposed = 12.8 p.s.f. Total Proposed Roof Dead Load LLr_proposed — 0.0 P. S. f. Roof Live Load with panels no more than 24in above roof surface (panels cannot support live loads, including the weight of stacked materials or workers) SLN = 30.00 p.s.f. Snow load (where modules are proposed) Check Proposed Gravity Loads: Total Existing Roof Load Wex = DLr1+ SLE = 41.0 p.s.f. Total Proposed Roof Load Wprop = DLrl_proposed + SLN = 40.8 p.s.f. Proposed Load Demand 416e ,� on Wprop- Wex _0,47% LESS THAN 5% INCREASE IN GRAVITY LOADS,, PA` OK! �« Wex 4of7 5/9/2019 2:16 PM ©McPherson Engineering Seismic Design Parameters Risk Category = 2 Site Class = D Ss = 0.19 Si = 0.06 S.D.C. = B Fa = 1.60 Fv = 2.40 SMS = SDS Fa = 0.30 SM1 = SD1 Fv = 0.14 SDS = 2/3 (SMS) = 0.20 SD1 = 2/3 (SM1) = 0.10 McPherson Engineering Lateral Loads Per Table 1-5-1 R = 6.5 Per 11.4.2 le = 1 Short Period P.G.A. 1 -Sec Period P.G.A. Seismic Design Category Per 11.6 Site Coefficient per Table 11.4-1 Site Coefficient per Table 11.4-2 Short Period M.C.E. Per Eq. 11.4-1 1 -Sec Period M.C.E. Per Eq. 11.4-2 Short Period Design Parameter Per Eq 11.4-3 1 -Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) T = Ct (hn)x hn= 16 ft Ct = 0.02 X = 0.75 T = 0.16 sec TL = 8 sec per Eq. 12.8-7 By: M.N.C. Date: 5/9/19 Response Modification Factor (Table 12-2.1) Seismic Importance Factor (Table 1.5-2) (per table 12.8-2) (per table 12.8-2) Approximate Fundamental Period Long -Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS le)/R = 0.03 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 - (SD1 le)/R T = 0.09 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T <_ TL Cs2 = 0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS le = 0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 le/R = 0.00 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S 1 >_ 0.69 CS = 0.03 Design Seismic Coefficient Check Additional Base Shear Wexisting = 14.0 kips Wpanels = 0.7 kips Vexisting = Cs Wexisting = 0.4 kips Vpanels = Cs Wpanels- 0.0 kips Vpanels 4.68% < 10% Vexisting 5/9/2019 2:16 PM Weight of Existing Structure city 01 Weight of Proposed Panels Ridgo Whect Base Shear of Existing Structure Base Shear of Proposed Panels guitdingDivW*n PER I.E.B.C. 1103.2 Exception #2, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 5of7 ©McPherson Engineering E McPherson Engineering Wind Uplift Anchorage Components and Cladding Design Wind Pressure per Simplified Method (Section 30.5, ASCE 7-10) Vult = 130 mph Exposure Category = C Roof Zone = 2 Panel 0 = 7-27 deg Pnet = A Kzt Pnet30 By: M.N.C. Date: 5/9/19 Pnet30 = 44.6 p.s.f. net design wind pressure for exposure B at In = 30ft per fig. 30.5-1 X = 1.21 adjustment factor for building height and exposure per fig. 30.5-1 Kzt = 1 topographic factor per 26.8 Pnet = 54.0 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL = 2.8 p.s.f. dead load of panel (inlcuding rack system) W = 54.0 p.s.f. wind load normal to face of panel Areala9 = 9.9 sq. ft. area tributary to each anchor SPanc = 6.0 ft. spacing of anchors Puplift = Areala9 (0.6DL - 0.6W) = 302.4 lbs total uplift on anchor Material = DFL lumber anchor material Diala9 = 5/16 in. diameter of screw Penlag = 2.5 in. min. penetration to existing framing Wla9 = 266 Ib/in. withdrawal load per in. of penetration per NDS Table 11.2A CD= 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 NOscrews = 1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews = 851.2 lbs total allowable withrawal on anchor Puplift 0.36 < 1.00 Anchor is OKI Pallow Anchorage = USE (1) 5/161N. DIA. LAG SCREW(S) AT 6FT. MAX. O.C. W/ 2.51N. MIN. PE TRA61-fbN O •. 6of7 5/9/2019 2:16 PM ©McPherson Engineering E � McPherson Engineering By: M.N.C. Date: 5/9/19 Summary Gravity Loads: DEMAND DECREASED BY .47% = OK! Lateral Loads: DEMAND INCREASED BY 4.68% < 10% = OK! Anchorage: DEMAND OF 302.41-13. < CAPACITY OF 851.21-6. = OK! USE (1) 5/161N. DIA. LAG SCREW(S) AT 6FT. MAX. O.C. W/ 2.51N. MIN. PENETRATION Summary: THE EXISTING STRUCTURE INFORMATION USED IN THIS ANALYSIS WAS PROVIDED BY FREEDOM SOLAR AND REVIEWED BY RYAN MCPHERSON, P.E. BASED ON THE INFORMATION PROVIDED, THE STRUCTURE IS CONVENTIONALLY FRAMED WITH 2x6 RAFTER AT 24" ON CENTER AND NO STRUCTURAL DEFICIENCIES WERE OBSERVED. LIVE LOAD IS PERMITTED TO BE OFFSET BY THE DEADLOAD OF SOLAR PER IBC SECTION 1607.12.5.1. THE ADDITION OF SOLAR PANELS THAT DO NOT PROTRUDE ABOVE THE EXISTING ROOFLINE DOES NOT INCREASE THE WIND LOADING ON THE STRUCTURE. THIS ANALYSIS INCLUDED A SEISMIC ANALYSIS TO ENSURE THAT THE ADDITIONAL DEAD LOAD DOESN'T OVERSTRESS ANY EXISTING LATERAL LOAD RESISTING ELEMENTS AS WELL, ALTHOUGH WIND LOADING PREDOMINANTLY CONTROLS THE DESIGN OF THIS STRUCTURE. IN SUMMARY, THIS STRUCTURE IS ADEQUATE FOR THE PROPOSED SOLAR ADDITION, DOES NOT REQUIRE RETROFIT, AND MEETS ALL CURRENT APPLICABLE CODE REQUIREMENTS. 5/9/2019 2:16 PM city of %gh0at Ridge 110 ing Division 7of7 ©McPherson Engineering TABLE OF CONTENTS PV -1 .►'. of PHOTOVOLTAIC SYS"�� PV -2 PV SYSTEM SUMMARY- 3.705 KW PV -2A CITY NOTES- Reviewed for CodeC010RUnce PV -3 ELECTRICAL LINE DIAGRAM PV -4 ROOF MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST SITE LOCATION. LABELS ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM OPTIMIZER CHART THIS PROJECT COMPLIES WITH THE FOLLOWING:2012 / International Building Code 1t{.•—� SYSTEM SIZE (DC) STC: 13 X 285= 3705W DC 2012 International Mechanical Code 6 1r 2012 International Plumbing Code planst.atniner Daae -' National Self PTC: 13 X 261.40 = 3398.20W DC 2012 International Energy Conservation Code 0 v�dgvstyeTh,-r.-ameofope�+toropp•owr610do'sspedfKorons Storage - Denver 2012 International Residential Code o/ndCon,pofntjonS Sholi not be u pe -191b, of on opwovw4t om to m _ SYSTEM SIZE (CEC-AC) 13 X 261.40 X 99% = 3364.22W AC 2012 International Fire Code onyofthe p,,0,ion;njthe buddingcode OrOf0"YCity oM►ences.pe""Is h - I70Se! 13 X HANWHA Q -CELL. Q PLUS BFR -G4.1 285, 285W 2012 International Fuel Gas Code presuming togweouthow; to vi weoJ cocotKelfhep�odfk�t�rhe8wbing des orothe.otdMoncesortheatyseateotbe„ot+d. MODULES MODULES 2017 National Electrical Code Notes: 2012 International Property Maintenance Code 1)Verify or provide supplemental ground rod or INVERTER SOLAR EDGE SE3800H-US [S11j AS ADOPTED BY CITY OF WHEAT RIDGE rods per 2017 NEC Art. 250.53(A)(2). 4773 Everett Court ROOF COMPOSITION SHINGLE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE 2) Natural Gas piping to be bonded s per 2017 NEC - MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR Art. 250.104(B). - r' TILT 18° PITCH TO THE SURFACE UPON WHICH THEY ARE MOUNTED 3)Bond P/V panels to the building Grounding Electrode System per 2017 NEC Art. 690(A). AZIMUTH 90° & 270° VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE RAFTER/TRUSS SIZE 2" X 6" RAFTERS @ 24" O.0 COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME. MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ATTACHMENT TYPE FLASH FOOT2 MOUNT WITH IRONRIDGE XR100 RAIL ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE EXISTING 200 AMPS MSP WITH 200 AMPS MAIN 1505.10F THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF I MAIN SERVICE PANEL THE BUILDING. CRC SECTION R902.4 `— SITE LOCATION BREAKER ON END FEED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. INTERCONNECTION PV BREAKER TIED INTO MSP RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE HOUSE AERIAL VIEW- OCPD RATING 20 AMPS NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN ACCORDANCE WITH CGBSC" STRINGING 1 STRING WITH 13 MODULES IN SERIES IN EACH SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: STRING --WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) -FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) UTILITY XCEL ENERGY -URINALS 1.0 GPF r SHOWER HEADS 2.5 GPM TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 SITE PLAN PV -2A ROOF PLAN WITH MODULES LAYOUT PV -3 ELECTRICAL LINE DIAGRAM PV -4 ROOF MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST PV -5 LABELS PV -6 OPTIMIZER CHART INSTALLATION NOTES: THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN - -� SERVICE BUSS RATING. " PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS INVERTERS. INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. i { EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF MODULE LOCATION Elect -al C-t—torNo CLIENT. REVISIONS: TITLE: SHEET: freedoms I C-10#1029644 FREE, JONATHAN & JESSICA DESCRIPTION DATE REVISION DATE 03/26/2019 4773 EVERETT CT, LAYOUT/MODULE CHANGE 5/2/19 1 DESIGN SITE LOCATION AND FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY: GREG PV -1 43445 Business Park Dr Suite 110, Temecula, CA 92590 (720) 251-3583 HOUSE AERIAL VIEW Tel: (800) 385-1075 Joe No.: FS -03-431 ROOF AREA: 1635.56 SQ FT 4 PROPERTY L'"'� 62'-2" FENCE LINE — nr�nr i Mir- BFR-G4.1 ir BFR-G4.1 285, 285W MODULESv m m x m n 9 ok Gip s �r�oti Seo oto•. 0J` N SITE PLAN 1 SCALE: 3/32" = V-0" De=t"co!ContwtwNo CLIENT"--' REVISIONS: TITLE: SHEET: C-10#1029644 DATE 03/26/2019 _ FREE, JONATHAN &JESSICA DESCRIPTION DATE REVISION / 4773 EVERETT CT, LAYOUT/MODULE CHANGE 5/2/19 1 DESIGN FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY GREG SITE PLAN PV -2 43445 Business Park Dr Suite 1101 Temecula, CA 92590 (720) 251-3583 Jog No. FS -03-431 Tel: (800) 385-1075 2" X 6" RAFTERS @ 24" O.0 (TYP) (N) SOLAR EDGE SE380OH-US [S11] INVERTER 0 (N) JUNCTION BOX (N) AC DISCONNECT (N) PRODUCTION METER Q(N) 3/4" OR LARGER EMT CONDUIT (E) MAIN SERVICE PANEL FIRE ACCESS PATHWAYS 4 (N) ATTACHMENT POINTS @Q 72" O.C. MAX. IRON RIDGE XR100 NOTE: O EMT CONDUIT SUPPORTED BY PIPE HANGERS 12" TO 18" AWAY FROM ROOF EDGE O ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES 0 JUNCTION BOX MOUNTED TO THE RAIL Digitally s- ea-Te—d by Ryan McPherson, P.E. on 5/9/19 LEGEND: ® CHIMNEY O PIPE VENT ow of VLAY�QU ROOF PLAN WITH MODUT 1 SCALE: 1/8" = V-0" I E'e°M-IC°"vz°t°'N° CLIENT REVISIONS. TITLE: SHEET. freedon, C-1011029644 FREE, JONATHAN & JESSICA DESCRIPTION DATE REVISION DATE: 03/26/2019 4773 EVERETT CT, LAYOUT/MODULE CHANGE 5/2/19 1 DESIGN ROOF PLAN WITH FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY GREG MODULES LAYOUT PV -2A 43445 Business Park Dr Suite 110, Temecula, CA 92590 (720) 251 3583 JOB No.: FS -03-431 Tel: (800) 385-1075 ROOF AREA STATEMENT ROOF MOQDT1LES PITCH AZIMUTH ROOF AREA ARRAY AREA 1 11 18° 90° 496.50 SQ FT 213.96 SQ FT 2 2 18° 270° 665.19 SQ FT 71.41 SQ FT (N) ATTACHMENT POINTS @Q 72" O.C. MAX. IRON RIDGE XR100 NOTE: O EMT CONDUIT SUPPORTED BY PIPE HANGERS 12" TO 18" AWAY FROM ROOF EDGE O ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES 0 JUNCTION BOX MOUNTED TO THE RAIL Digitally s- ea-Te—d by Ryan McPherson, P.E. on 5/9/19 LEGEND: ® CHIMNEY O PIPE VENT ow of VLAY�QU ROOF PLAN WITH MODUT 1 SCALE: 1/8" = V-0" I E'e°M-IC°"vz°t°'N° CLIENT REVISIONS. TITLE: SHEET. freedon, C-1011029644 FREE, JONATHAN & JESSICA DESCRIPTION DATE REVISION DATE: 03/26/2019 4773 EVERETT CT, LAYOUT/MODULE CHANGE 5/2/19 1 DESIGN ROOF PLAN WITH FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY GREG MODULES LAYOUT PV -2A 43445 Business Park Dr Suite 110, Temecula, CA 92590 (720) 251 3583 JOB No.: FS -03-431 Tel: (800) 385-1075 neat nr.Pn. (200A Bus) ` (1.2) = 240A Max Rating (120% of Bus) PV Backfeed (20A) + Main Breaker (200A) = (220A <— 240A) See 705.12 (D)(2)(3)(b) of 2017 NEC TOTAL DC kW: 4.4 kW NOTES: TOTAL AC kW: 3.8 kW - PV PRODUCTION METER SHALL BE LOCATED 10 FEET WITHIN THE MAIN BILLING METER - "PHOTOVOLTAIC SYSTEM CONNECTED" YELLOW WITH BLACK LETTERING PLACARD TO BE LOCATED ON MAIN BILLING METER - "PV AC DISCONNECT' YELLOW WITH BLACK LETTERING PLACARD TO BE LOCATED ON AC DISCONNECT 2 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) INVERTER SOLAR EDGE SE380OH-US [S11] RAPID SHUTDOWN STRING -1 7C SWITCH 13 HANWHA Q -CELL. Q PLUS BFR -G4.1 \ 285,285W MODULES DC\ AC DISCONNECT 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT General Notes JUNCTION ' BOX 3 - #6 AWG, THWN-2 SOLAREDGE P320 POWER OPTIMIZERS 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT 1. (13) HANWHA Q -CELL. Q PLUS BFR -G4.1 285, 285W MODULES wired and listed to UL1703 standards 2. SOLAR EDGE SE380OH-US [SI 1] Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per 2017 NEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2017 NEC 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8 -inch -high white lettering on red background reading :"WARNING: PHOTOVOLTAIC POWER SOURCE" STEEL PRODUCTION METER,120/240V 3 -WIRE, IN COMPLIANCE WITH SECTION 4.11 OF THE XCELENERGY STANDARD (E) 200A MAIN (E) UTILITY SERVICE PANEL METER (E) 200A / 2P MAIN --— — --—— — — — BREAKER - — — -- (END FED) — I U l TO OTHER LOADS (N) 20A / 2P PV BREAKER 4.14.4 METER --— — --—— — — — --- -- 4.14.4METER SOCKET_ IDENTIFICATION PV PROD 4773 Notes: 1)Verify or provide supplemental ground rod or rods per 2017 NEC Art. 250.53(A)(2). 2) Natural Gas piping to be bonded s per 2017 NEC Art. 250.104(B). 3)Bond P/V panels to the building Grounding Electrode Svstem per 2017 NEC Art. 690(A). - CONNECT TO EXISTING LIFER i 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of NEC 2017 table 250.66, not smaller than #8 CU AWG." 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. Whet R�d9e 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. B`�d��g�,v s� 16. PV system is using continuous grounding method with #6 bare copper wire. Eieocn=aic^^i'a=^'"^ CLIENT: REVISIONS TITLE: SHEET DESCRIPTION DATE REVISION : C-10#1029644 FREE, JONATHAN & JESSICA DATE 03/26/2019 - 4773 EVERETT CT, LAYOUT/MODULE CHANGE 5/2/19 1 DESIGN ELECTRICAL FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY GREG LINE DIAGRAM PV -3 43445 Business Park Dr Suite 110, Temecula, CA 92590 (720) 251-3583 Tel: (800) 385-1075 JOB No.: FS -03-431 PV MODULE, BY OTHERS IRONRIDGE RAIL (E) ROOF MEMBRANE IRONRIDGE FLASHFOOT2 (E) BUILDING STRUCTURE oR00 Or X01, - P�j.F.si MSA N.jF 541 75 �o W_ Digitally sea ed by Ryan McPherson, P.E. on 5/9/19 ELECTRICAL CALCULATIONS PV MODULE, BY OTHERS BACKFEED BREAKER SIZING IRONRIDGE MAX. CONTINUOUS OUTPUT 16A @ 240V RAIL (E) ROOF 16 X 1.25 = 20.00AMPS 20A BREAKER - OK MEMBRANE NEC 705.12 (D) (2) (3) (b) FLASHFOOT2 IRONRIDGE 200 X 1.20 = 240 240 - 200 = 40A ALLOWABLE BACKFEED (E) BUILDING STRUCTURE DE -RATED AMPACITY OF6 AWG CONDUCTOR @ 0.96 TEMPERATURE CORRECTION 75 X 0.96 = 72.00 AMPS - OK Embedment Photovoltaic Panel Mounting Detail Scale: NTS Ith 6"max MATERIAL LIST QTY EQUIPMENT DESCRIPTION HANWHA Q -CELL. OPEN CIRCUIT VOLTAGE (Voc) : 39.22V Q PLUS BFR -G4.1 MAX. POWER VOLTAGE (Vmp) : 31.99V 13 285 285W SHORT CIRCUIT CURRENT (Isc) : 9.46A MAX. POWER CURRENT (Imp) : 8.91A MODULES PTC RATING.' 261AW SOLAR EDGE MAX. DC INPUT VOLTAGE: 480V SE380OH-US [S11] MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 WITH POWER MAX. AC OUTPUT CURRENT: 16A MAX. AC POWER OUPUT : 380OW OPTIMIZERS CEC EFFICIENCY: 99% 1 JUNCTION BOX 600VDC, NEMA 3R, UL LISTED 1 AC DISCONNECT 240VAC, 30A, NEMA 3R, UL LISTED 1 PRODUCTION METER 1 PV BREAKER 2 POLE, 240V, 20A 42 ATTACHMENTS FLASH FOOT2 MOUNT 175' RAIL IRONRIDGE XR100 IRONRIDGE XR100 GROUNDING 22 MID CLAMPS MID CLAMPS 20 END CLAMPS IRONRIDGE XR100 END CLAMPS 50' CONDUIT 3/4" OR LARGER EMT CONDUIT city of Wheat Ridge F Division E11111,C21C-1111l0,NG CLIENT: REVISIONS: TITLE: SHEET C-10#1029644 FREE, JONATHAN &JESSICA DATE 03/26/2019 ROOF MOUNTING {y * J" ,r I r f DESCRIPTION DATE REVISION "fir LAYOUT/MODULE CHANGE 5/2/19 1 DETAILS ELEC. 4773 EVERETT CT, DESIGN C FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY: GREG PV -4 (720) 251-3583 CALCULATION & 43445 Business Park Dr Suite 110, Temecula, CA 92590 JOB NO.: FS -03-431 MATERIAL LIST Tel: (800) 385-1075 "WARNING" INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE (UNLESS BUSBAR IS FULLY RATED) 705.12(D)(2) PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN "WARNING" ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. 690.35(F) ARRAY J/B CEC 690.31(G)(3) & (4), CRC R324.7 "WARNING" PHOTOVOLTIC POWER SOURCE EVERY 10' ON COUNDUIT AND ENCLOSURES M1 u DC L W LU Z "WARNING" DUAL POWER SOURCES SECOND SOURCE IS PHOTO- VOLTAIC SYSTEM RATED AC OUTPUT CURRENT -16 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS 690.54 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT -16 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS 690.14, 690.15, 690.54 "WARNING" ELECTRIC SHOCK HAZARD IF A GROUND- FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. 690.5(C) DIRECT CURRENT PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE - 240 VDC MAX CIRCUIT CURRENT -16 AMPS "WARNING" ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. 690.17 PV SYSTEM DC DISCONNECT OPERATING CURRENT: 9.75A OPERATING VOLTAGE: 380.00V SHORT-CIRCUIT CURRENT: 15.00A MAX SYSTEM VOLTAGE: 480.00V 690.14(CO(2)), 690.15, 690.53 NOTES: 1. CEC ARTICLES 690 AND 705 AND CRC SECTION R324 MARKINGS SHOWN HEREON 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SING MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO -PLATING B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK C. ARIAL FONT 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT POP -RIVETS OR SCREWS. CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN. DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES INVERTER EQUIPPED z WITH RAPID SHUTDOWN m JUNCTION BOX m AC DISCONNECT n m PRODUCTION METER 13 PV MODULE Li ILI MAIN SERVICE PANEL N \age ems` Elactnoal contractor No CLIENT: REVISIONS: TITLE. SHEET C 10#1029644 FREE, JONATHAN &JESSICA DESCRIPTION DATE REVISION DATE 03/26/2019 4773 EVERETT CT, LAYOUT/MODULE CHANGE 5/2/19 1 DESIGN FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY GREG LABELS PV -5 43445 Business Park Dr Suite 110, Temecula, CA 92590 (720) 251-3583 Tel: (800) 385-1075 Joe No.: FS -03-431 1 2 3 .49 5 0 7 0 it 1-10 11-20 21-30 31-40 41-50 51-60 eieoo-aicom111111N° CLIENT: REVISIONS: TITLE: SHEET: C-10#1029644 03/26/2019 FREE, JONATHAN & JESSICA DESCRIPTION DATE REVISION DATE: 4773 EVERETT CT, LAYOUT/MODULE CHANGE 5/2/19 1 DESIGN OPTIMIZER FREEDOM FOREVER LLC WHEAT RIDGE, CO 80033 AHJ CORRECTIONS CODES 5/8/19 2 BY GREG PV -6 (720) 251-3583 CHART 43445 Business Park Dr Suite 110, Temecula, CA 92590 JOB NO.: FS -03-431 Tel: (800) 385-1075 Mono Multi Solutions THE A,: MAX"PL FRAMED 60 -CELL MODULE 60 CELL MONOCRYSTALLINE MODULE 275-315W POWER OUTPUT RANGE 19.2% MAXIMUM EFFICIENCY 0-+5W POSITIVE POWER TOLERANCE Founded in 1997, T nna Sola is the world's leading comprehensive solutions provider for solar energy we believe close cooperation with our partners is c-rtical to success Trina Solar now distributes its PV products to over 60 counties all over the world, Tina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Tina as as strong, bankable partner. We are committed to building st•ategic, mutually distributors and other partne-s Comprehensive Products And System Certificates IEC61215/IEC61730/UL1703/IEC61701/IEC62716 ISO 9001 Quality Management System 150 14001. Environmental Management System ISO14064. .,.. . OHSAS 18001. Occupation Health and Safety Management System °pa- C E Ars ^-•. PY�YCLE Trinasolar Maximize limited space with top -end efficiency r operating temperatures Highly reliable due to stringent quality control o • Over 30 In-house tests (UV, TC HF, and many more) PID resistant 1000/c EL double Inspection . Soldr V- , - advan -. -'r k`. Certified to withstand the most challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load • 35 mm hall stones at 97 km/h LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty 25 Year Linear Power Warranty too." 97`-•- Add,Gonal - value /rom Inn a Solar's linear -_ warranty E Trina Linear Warranty Standard Step Warranty A!'_MAX"'PLUT 35/1.38 PRODUCTS POWERRANGE TSM-DD05A.08(11) 280-315W TSM -0005A.05(11) I 275-31OW DIMENSIONS OF PV MODULE(mm/inches) 993/39.1 Back View 11/0.43 Lkcm Sea Wt 35/1.38 (A -A) I-V CURVES OF PV MODULE(305W1 4. 3. o ,a x as so p votlagetV) P -V CURVES OF PV MODULE(305W) 1 wmvm 2. mmr� ,so a ,o ra vokageM so FRAMED 60 -CELL MODULE ELECTRICAL DATA (STC) Peak Power Watts-Pw,x (Wp)' 275 280 285 290 295 300 305 310 315 Power Output Tolerance-Pwx (W) 205 209 212 216 0-+5 223 227 231 235 Maximum Power Vo@age-V.wc(V) 31.4 31.7 31,8 32.2 32.5 32.6 32.9 33.1 33.3 Maximum Power CUfrent-l1Pe(A) 8.76 8.84 8.97 9.01 9.08 9.19 9.28 9.37 9.46 Open Circuit Voltage-VocIV) 38.4 38.4 38.5 38.9 39.6 39.6 40.0 40.2 40.5 Short Circuit Current-lsc(A) 9.24 9.42 9.51 9.66 9.68 9.77 9.85 9.94 10.0 Module Efficiency ri. (%) 16.8 17.1 17.4 17.7 18.0 18.3 18.6 18.9 19.2 STC Ir --u ce1-0W/m'. 0Cell Temperature 25°C. A., Mass AM 'Measur.ngrole,ance .3% ELECTRICAL DATA (NOCT) Monocrystalline 156.75 x 156.75 mm (6 inches) Cell Orientation 60 cells (6 x 10) Module Dimensions 1650 x 992 x 35 mm (65.0 x 39.1 x 1.38 inches) Weight 18.6 kg (41.0 lb) Glass 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass Maximum Power-Pnnx(Wp) 205 209 212 216 220 223 227 231 235 Maximum Power Voltage -V- IV) 29.1 29.4 29.5 29.9 30.1 30.2 30.5 30.7 30.9 Maximum Power CUfrent-Irreo(A) 7.04 7.10 7.21 7.24 7.30 7.38 7.46 7.53 7.60 Open Circuit Voltage-Voc(V) 35.7 35.7 35.8 36.2 36.8 37.0 37.2 37.4 37.6 Short Circuit Current -is, (A) Noc- Irma ante at BZZ Wr'. A -b est Tempe,atu,e 7.46 20°c. 7.61 7.68 W -d Sreed 1 m,s 7.80 7.82 7.89 7.95 8.03 8.10 Solar Cells Monocrystalline 156.75 x 156.75 mm (6 inches) Cell Orientation 60 cells (6 x 10) Module Dimensions 1650 x 992 x 35 mm (65.0 x 39.1 x 1.38 inches) Weight 18.6 kg (41.0 lb) Glass 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass Backsheet White [DD05A.08(11)]; Black [DD05A.05(II)] Frame Black Anodized Aluminium Alloy [DDOSA.08(Il), OD05A.05(II)] J -Box IP 67 or IP 6B rated Cables Photovoltaic Technology Cable 4.Omma (0.006 inches), 1000 mm (39.4 inches) Connector MC4 Fire Type Type 1 or Type 2 TEMPERATURE RATINGS MAXIMUM RATINGS NOCTINpa,�„,lDp<,atingceoTpmprrarmel 44-C (±2-C) Operational Temperature-40-•+85oC Temperature Coefficient of P -x - 0.39%/°C Maximum System Voltage 1000V DC (IEC) Temperature Coefficient of Von - 0.29%/°C 1000V DC (UL) Temperature Coefficient of IK 0.05%/aC Max Series Fuse Rating 15A (Power <285W) 20A(Power >290W) (Do NOT connect F„se in combine, Box with two o• more strngs n para e connx ) WARRANTY PACKAGING CONFIGURATION 10year Product Workmanship Warranty Modules perbox: 30 pieces 25 year Linear Power Warranty Modules per 40'container: 840 pieces \ O (Pease refer m warranty for deta,is) 61\1product GS eo�n CAUTION, READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT, �ri�1O Tr in a so I a r © 2017 Trina Sola• Limited. All rights reserved. Specifications included in thisdatasheet are subject to change without notice. Version number, TSM_EN_2018_C www,trinasolarco�nJS\(jS� The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. Mitsubishi Modules with 35, 40, or 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" is CH Astronergy Solar or A, "yy" is either 10 or 12; and "zz" is blank or (BL). Frameless modules with model identifier Motech CHSM6610P(DG)-xxx. Axitec Modules with 35 or 40mm frames and model identifier AC-xxxY/aa-ZZ; where °Y" is M or P, "aa" is 125 or 156, and "ZZ" is 54S, 60S or 72S. Panasonic Modules with 35 and 40mm frames and model identifier CSbY-xxxZ; where "b" can be 1, 3 or 6, "Y" can Canadian Solar be K, P, U, V, or X; and "Z" can be M, P, AG, MS, PX, M -SD, P -AG, P -FG or P -SD, MS -AG, MS -FG, or Phono Solar MS -SD. Frameless modules with model identifier CSbY-xxx-FG; where "b" can be 3 or 6; "Y" is K, X, or P; and "Z" can be M -FG or P -FG. ET Solar Modules with 35, 40, or 50mm frames and model identifier ET-Y6ZZxxxAA; where "Y" is P, L, or M, "ZZ" REC Solar is 60 or 72, and "AA" is WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC. Modules with 35, 40, or 50mm frames and model identifier FXS-xxxYY-ZZ; where "xxx" is the module Flex power rating; "YY" is BB or BC; and "ZZ" is MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAA1 W, SAC1 B, SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W. GCL Modules with 35 and 40mm frames and and model identifier GCL-a6/YY xxx; where "a" can be M or P, and "YY" can be 60, 72, or 72H. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY; where "YY" is either PB or MB. Hanwha Solar Modules with 40, 45, or 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" is either 60 or 72; "YY" is PA or PB; and "Z" is blank or B. Modules with 32, 35, 40, and 42mm frames and model identifier aaYY-ZZ-xxx; where "aa" can be O. or B ; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO, and "ZZ" can be G3, G3.1, Hanwha O CELLS G4, G4.1, L -G2, L -G2.3, L -G3, L -G3.1, L-G3y, L -G4, L -G4.2, L-G4y, LG4.2/TAA, BFR -G3, BLK-G3, BFR -G3.1, BLK-G3.1, BFR -G4, BFR -G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/TAA, G4.1/ MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC -G4.4, G5, BLK-G5, L -G5.2, or L-G5.2/H. Heliene Modules with 40mm frames and model identifier YYZZxxx, where "YY" is 36, 60, 72, or 96; and "ZZ" is M, P, or MBLK. Hyundai Modules with 35, 40 and 50mm frames and model identifier HiS-YxxxZZ, where "Y" can be M or S; and "ZZ" can be MI, MF, MG, SG, RI, RG(BF), RG(BK), TI, or TG. Itek Modules with 40 or 50mm frames and model identifier IT-xxx-YY; where "YY" is blank, HE, or SE, or SE72. Modules with 35, 40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa'where "yy" can be M, P, JA Solar M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) (TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, 72, 60501 or 72501; and "aa" can be MP, SI, SC, PR, RE, 3BB, 4BB, 4BB/RE, 5BB. Modules with 40mm frames and model identifier JKMYxxxZZ-aa; where "Y" is blank or S, "ZZ" is P, Jinko PP, M, and "aa" is 60, 60B, 60-J4, 60B -J4, 60(Plus), 60-V, 72, or 72-V. Frameless modules with model identifier JKMxxxPP-DV. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" is D or U, "ZZ" is blank, GX, or Kyocera SX; and "AA" is LPU, LFU, UPU, LIPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 413C, 4FC, 4UC, SAC, SBC, SFC, 5UC, 613C, 6FC, 813C, 6MCA, or 6MPA. LG Modules with 35, 40, and 46mm frames and model identifier LGxxxYaZ-bb; where "Y" is A, E, N, Q, S, a" is 1 or 2, "Z" is C, K, T, or W, and "bb" is A3, A5, B3, G3, G4, or K4. Longi Modules with 40mm frames and model identifier LR6-YY-xxxM; where "YY" can be 60, 72, or 72HV. Mission Solar Modules with 40mm frames and model identifier MSExxxZZaa; where "ZZ" can be MM, SE, SO or SO, and "aa" can be 1 J, 4J, 4S, 5K, 5T, 6J, 6S, or 6W. Mitsubishi Modules with 46mm frames and model identifier PV-MYYxxxZZ, where "YY" is LE or JE; and "ZZ" is either HD, HD2, or FB. Motech IM and XS series modules with 40, 45, or 50mm frames. Neo Solar Power Modules with 35mm frames and model identifier D6YxxxZZaa; where "Y" can be M or P, "ZZ" can be 133A, B4A, E3A, E4A, H3A, H4A; and "aa" can be blank, (TF), ME or ME (TF). Panasonic Modules with 35 or 40mm frames and model identifier VBHNxxxYYzz, where "YY" is SA or KA; and "zz" is 01, 02, 03, 04, 06, 06B, 11, 11 B, 15, 15B, 16, 16B, 17, or 18. Phono Solar Modules with 35, 40, or 45mm frames and model identifier PSxxxY-ZZ/A; where "Y" is M or P, "ZZ" is 20 or 24; and "A" is F, T or U. Prism Solar Frameless modules with model identifier BiYY-xxxBSTC; where "YY" is 48 or 60. REC Solar Modules with 30, 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" is M, PE, TP, or TP2S'and "ZZ" is blank, BLK, SLV, or 72. Renesola Modules with 35, 40 or 50mm frames and model identifier JCxxxY-ZZ; where "Y" is F, M or S, and "ZZ" is Ab, Ab -b, Abh, Abh-b, Abv, Abv-b, Bb, Bb -b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db -b. Renogy Modules with 40 or 50mm frames and model identifier RNG-xxxY; where "Y" is D or R S -Energy Seraphim Energy Group Seraphim USA Sharp Silfab Solaria SolarTech SolarWorld Stion SunEdison Suniva Sunpower Sunpreme Suntech Trina Winaico Yingli Modules with 40mm frames and model identifier SNxxxY-ZZ; where "Y" is M or P, and "ZZ" is 10, or 15. Modules with 40mm frames and model identifier SEG-6YY-xxxZZ, where "YY" can be MA, MB, PA, PB; and "ZZ" can be BB, WB, or WW. Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY" can be MA, MB, PA, PB, QA -XX -XX, and QB -XX -XX. Modules with 35 or 40mm frames and model identifier NUYYxxx; where "YY" is SA or SC. Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" is SA or LA, SG or LG; and "Z" is M, P, or X. Modules with 40mm frames and model identifier PowerXT xxxY-ZZ; where "Y" can be R or C, and "ZZ" is BX, BY, PX, PZ, WX or WZ. Modules with 42mm frames and model identifier STU-xxxYY; where "YY" can be PERC or HJT. Sunmodule Plus, Protect, XL, Bisun, Bisun XL, may be followed by mono, poly or duo and/or black or bk; modules with 31, 33 or 46mm frames and model identifier SW-xxx. Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film frameless modules with model identifier STL-xxx or STL-xxxA. Modules with 35, 40, or 50mm frames and model identifier SE-YxxxZABCDE; where "Y" is B, F, H, P, R, or Z, "Z" is 0 or 4; "A" is B, C, D, E, H, I, J, K, L, M, or N, "B" is B or W, "C" is A or C; "D" is 3, 7, 8, or 9, and "E" is 0, 1 or 2. Modules with 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72, "B" is either 4 or 5, "YYY" is either 100,101,700,1 BO, or 1 B1; and "Z" is blank or B. Modules with model identifier Ab-xxx-YY and standard (G3) or InvisiMount (G5) 46mm frame, where "A" is either E, P or X, "b" can be 17, 18, 19, 20, 21, or 22, and "YY" can be blank, NE, BLK, COM, C -AC, D -AC, BLK-C-AC, or BLK-D-AC. Frameless modules with model identifier GXB-xxxYY where "YY" is blank or SL. Vd, Vern, Wdb, Wde, and Wd series modules with 35, 40, or 50mm frames. Modules with 35, 40 or 46mm frames and model identifier TSM-xxxYYZZ, where "YY" is PA05, PC05, PD05, PA14, PC14, PD -14, PE14, or DD05; and "ZZ" is blank, A, A.05, A.08, A.10, A.18, .05. .08_10_18, .18, .08D, .18D, 0.82, A.082(II), .002, .00S, 05S, 08S, A(II), A.08(II), A.05(II), A.10(II), or A.1 8(11). Frameless modules with model identifier TSM-xxxYY; and "YY" is either PEGS, PE05.07, PEG14, DEG5(II), DEG5.07(II), or DEG14(II). Modules with 35 or 40mm frames and model identifier Wsy-xxxz6, where "y" is either P or T; and ""z"" is either M or P. wheotR1d9e �a<< tn9 01 Ailoll 0114 o1 Panda, YGE, and YGE-U series modules with 35, 40, or 50 mm frames. Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE500OH-US / SE600OH-US SE760OH-US / SE1000OH•-US / SE1140OH-US W= -low Optimized installation with HD -Wave technology / Specifically designed to work with / Extremely small power optimizers / Record-breaking efficiency / Built-in module -level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar-• • l, I Sin le Phase Inverter with H D -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 6000 @ 240V 5000 7600 10000 l VA - 15500 j felf 5000 @ 208V Yes w� Maximum Input Voltage Maximum AC Power Output 3000 3800 @ 240V ! 6000 @ 240V 5000 7600 10000 s VA 10.5 1 13.5 16.5 20 3300 @ 208V ! 5000 @ 208V Adc Maximum Input Current @208VO - 10000 @ 208V 13.5 - AC Output Voltage Min. -Nom. -Max. 27 Adc i 45 Adc Vac (211 240 264) Ground -Fault Isolation Detection _.. Maximum Inverter Efficiency 99 Optimized installation with HD -Wave technology / Specifically designed to work with / Extremely small power optimizers / Record-breaking efficiency / Built-in module -level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar-• • l, I Sin le Phase Inverter with H D -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 6000 @ 240V 5000 7600 10000 11400 @ 240V VA - 15500 3300 @ 208V 5000 @ 208V Yes 10000 @ 208V Maximum Input Voltage Maximum AC Power Output 3000 3800 @ 240V ! 6000 @ 240V 5000 7600 10000 11400 @ 240V VA 10.5 1 13.5 16.5 20 3300 @ 208V ! 5000 @ 208V Adc Maximum Input Current @208VO - 10000 @ 208V 13.5 - AC Output Voltage Min. -Nom. -Max. 27 Adc i 45 Adc Vac (211 240 264) Ground -Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 AC Output Voltage Min. -Nom. -Max. % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Vac (183 - 208 - 229) W ADDITIONAL FEATURES Supported Communication Interfaces AC Frequency (Nominal) 59.3 - 60 - 60.5m Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V i Safety UL1741, UL1741 SA, UL169913, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards Maximum Continuous Output - 16 -24 FCC Part 15 -Class B - 48.5 A Current @208V AC Output Conduit Size / AWG Range 314` minimum / 146 AWG 3J4` minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range GFDI Threshold 1 A Utility Monitoring, Islanding 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 165 Protection, Country Configurable Yes 1 25.1 / 11.4 1 26.2/11.9 Thresholds Ib / kg Noise INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 - 7750 - 15500 1 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V" 8.5 ! 10.5 1 13.5 16.5 20 27 1 30.5 Adc Maximum Input Current @208VO - 9 1 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optionale} Rapid Shutdown -NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL169913, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 -Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 314` minimum / 146 AWG 3J4` minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4" minimum / 1-2 strings / 14-6 AWG 3/4` minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (H%WXD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 165 in / i mm Weight with Safety Switch 22110 1 25.1 / 11.4 1 26.2/11.9 38.8/17.6 Ib / kg Noise < 25 <50 Ot dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +60(`) (-407 / -40°C option)"' 'F/'C Protection Rating NEMA 4X (Inverter with Safety Switch) A 0) For other regional settings please contact SolarEdge support A higher current source may be used; the inverter will limit its input current to the values Rated Revenue grade inverter P/N: SExxxxH-US000NNC2 For power de -rating information refer to: hnps://www.solaredge.com/sites/defauiVfiles/se-temperatire-derating-note-na.pdf -40 version P/N: SExxxxH-US000NNU4 ® solarEdge Technologies, Inc. All rights reserved. SOLAREDGF, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12„ 2018/VOt/ENG NAM. Subject to change without notice. U��dtt�g ` i��RoHs sH011 3 uo±slAia Buiplm8 06p!a loey/A )O App m 'a>pcu 0044-a6ueya W P* -S WAN 9N3AaA18IW,n ageo w4wds iIatR to 9Yv+pe4 ale uWN pauopuaw sVmapwi iaylo Iry �ul'ssi6olw+Y 1a6R3+epS4.-V—P-4P--W.6-I-'WewaPe4 ale MAY105 A9 GMAQid0'ofal e6p31eWSa07 manvios P-- q46P IIY'P71 .6P31 -PS !S mC00'Z p do sl sbu,15 agy uaamlaq axwwaMp jamod wnwKew au1 uogm pue (sn)100L3S/Snx9'993s I(4 llun lad s6u!4s £) jallaAu! aqy of payxuuCO We SLwu>s E a94M buoys gad MoWsL 01 do IIe1su of Pahgle s! 71:SM10013s/sm9-993s/sn>IE££35'Smms joi MofY of do si s5ups aL4 uaamlaq aauaraglp iauod wnwmew ayt ua4m Pue (ffUIZ'EY3s x4)!un jad s5ulAs E) galla ui alp cq pa•,,auuc) aie s6upy E uaqm 5ups uad MOOS'9 0; do l!e¢ul of paAti-91e sl 8 sruz E435/Snn- PL35.03 luawarnba, AO£ aq1 awge aq;Lm a6elloA (,tales 'sivawaunbal unwpl."u{s p!de1 03N laaw'm saoP slaz!wado OE ue p avow 48m 6ullz V;;, 6u!J$ duo w 00l'd/OLEd/04£d/Md LRm 505d/S0Vd ww 0a Pamolle lou s! 11 ypd eu'6u!ns St:uE/sal�r7InelaP/�JsN 'a6Pael�'m^v^//:dA4 =o1. uaiW uc4ewrolw gums 6uu1S Wllelap.oj suo!leluaup 10 saA s416ual lualay!p;o s6uulS lalle)ed (sn OWL 10009� OSZS-OOML3S Sn-009L35 6uulS Sad 3amod wnw!xely 44lm 0009) DOLS SOS SZ I SZ g46ual 6uulS wnw!xe" 41. 8 9 SOSd / SOhd I(sazlunldo Jamod) 8L OL 8Dodd Lp6ual 6uulS wnw!u!V! 'OL£d'OVEd `OZEd E-9-OOMD31 "Z-9-0000D3!'B sseD Swed »d 0W3 3:)NVndWO:) GWONVIS DPA 0 { L :az!wpdo ,amod Sad a6elloA lndlno LlaleS WdO HILIGANI 3S)a3VVlOS VO t131MNI1903HV1QS WOIid (13n3NN :)Sla'd3ZIWLLdO H MO& A90NV.LS E)NMno lndino DPA SS 09 96elloA ]ndin0 wnw!xe!y DPV SL luaunD lndMO wnwlxe!A! (a31'83ANI 3903WVlGS DNILVII3dO 01(331ANNOD W32IWUdO II'3MOd) NOLLVV3dO s)Nrdna indinO % 1 9'86 1 8'86 1 �OuaP413 Pa146!aM % I S'66 I foualDLy3 wnu1!xe!y :)PV S'L1. E9'ZL a6NMOS MuW asea!d sadhl "pauw) ,agio 1o3 �. A08 ue4l wow lou aq a6elloA lndui xew sairmai LLoz D3N pamolle awe •alol jamod %5+ al do p alnpoVi 'appow a,4 )o iamod :)1S palet' % 001-0 !4!piwnH anllelad DPA E8 - SZL d9VW3N / 89di 6ulle8 uo!haaoJd D. SBL+ - 01,- / S8+ - O1,- abued alnleadwal 6ugelado 4/w ZS'O / 9L'0 416ual aI!m lndul ll / w 6'E / ZL 0'E / S6'O 416ual al!m lndln0 tDVW 'palelnsul algnoC) jupouuoD / adRl anm indln0 lndui wnw!xey4 alnlosgV (o1. DN 3olDauuoD lndul q1. / u6 ET / 1,901. 61 / SV9 L't / OSL 1,'l / OE9 (salgeo 6uipnpu)146!am u!/ww E'ZxV9xCS /6SXMx62L 6'lx£'9xCS Elx9x[S /S'61,x6SLx6ZL /S-E£xESLx6ZL CLx9xL's /S'LZxESL x6Zl CHxIxm)suo!suaw!Q siaUanw ase4d aa'41 pue ase4d al6u!S a5p3JeloS IIV sjaljanul alq!ledw0D DPA ( OOOL a6elloA walsAS pamollV wnwlxeyy San SNOLLVDIMUS NOLIV1lV1SNI SHoa wmn "(Alales p sselD) L -6029D31 Nates E-9-OOMD31 "Z-9-0000D3!'B sseD Swed »d 0W3 3:)NVndWO:) GWONVIS DPA 0 { L :az!wpdo ,amod Sad a6elloA lndlno LlaleS WdO HILIGANI 3S)a3VVlOS VO t131MNI1903HV1QS WOIid (13n3NN :)Sla'd3ZIWLLdO H MO& A90NV.LS E)NMno lndino DPA SS 09 96elloA ]ndin0 wnw!xe!y DPV SL luaunD lndMO wnwlxe!A! (a31'83ANI 3903WVlGS DNILVII3dO 01(331ANNOD W32IWUdO II'3MOd) NOLLVV3dO s)Nrdna indinO % 1 9'86 1 8'86 1 �OuaP413 Pa146!aM % I S'66 I foualDLy3 wnu1!xe!y :)PV S'L1. E9'ZL SL'EL luaun:) lndul Dd wnw!nN DPV41. VOL 1.L (D60 luaunD l!rDJ!D uo4S wnw!xe!A! DPA E8 - SZL SOL - SZL OB - B 09-9 ) 86 - 8 e5ued 6u!leado IddW (ainleadusl lsamol le DDA) DPA mE8 WSZL 08 09 8v 06el10A lndui wnw!xey4 alnlosgV m SOS S06 OOb OLE OSE OZE up,—od D4 indul paled i nAfJi SOSd / SOtbd / OOt7d / OLEd / OVEd / OZEd e:)iaaWV 44JON JOJ aaziwildp J9MOd 3 I(lajes Aal46ilajl; pue Aallelsul joj umopin4s a(5elloA larval-alnpoh I (SS'8Ad) WaIS (S UMOPIn4S pide)i :)iell0nol04d pue (17d'd) uoil:)aloJd ilne} aae joj sluawa.nnbaj 73N SIaaVV J 6ulJolfuow lana) -alnpow 41!+w aaueualuiew uotleaaua6 IxaN I flog 016uls a LII!M u01lellelsul ised f wo)-a6paiefos uallezlllln meds wnwlxew dol u61sap walsAs alglxal j I 6ulpe4s le±1jed of nuejolol 6ulanl:)e;nuew woal 'sassol 4:)lewsiw alnpow jo sadAl Ile sale6ll!Vq I (%s-66) bualal;#a aolaadnS A6iaua ajow %5Z of do / SJOIJaAui e6paJel0S 411M 4iom of pau61sap Alle3lipadS I lanal-"alnpow aq4 le uoileziwildo jamod Ad SOSd / SOt�d / OOt7d / OLEd / Ot Ed / OZEd e:)iaawV gPON JOJ Ja i L,lll�.d aamOd 4 A �. I RON RI DGE Flush Mount System c IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20 -year warranty. Strength Tested ? All components evaluated for superior structural performance. PE Certified Pre -stamped engineering letters _._ _.. available in most states. Design Assistant Online software makes it simple to create, share, and price projects. XR Rails XR10 Rail A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Attachments U FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Stopper Sleeves 11 Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L -Feet Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Bond and attach XR Rails to certified attachments. • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated Design Assistant UL 2703 Listed System 20 -Year Warranty Go from rough layout to fully a � ' engineered system. For free. Entire system and components meet Twice the protection offered by __•v._y: newest effective UL 2703 standard. x competitors. Bonded Splices k All rails use internal splices for seamless connections. • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits wok Mount MIs or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training Earn free continuing education creditC;%" while learning more about our systems. ae -- t o to lro� iRiira$j� cx)i nftxainirig whe Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. PE Certified Pre -stamped engineering letters _._ _.. available in most states. Design Assistant Online software makes it simple to create, share, and price projects. XR Rails XR10 Rail A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Attachments U FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Stopper Sleeves 11 Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L -Feet Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Bond and attach XR Rails to certified attachments. • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated Design Assistant UL 2703 Listed System 20 -Year Warranty Go from rough layout to fully a � ' engineered system. For free. Entire system and components meet Twice the protection offered by __•v._y: newest effective UL 2703 standard. x competitors. Bonded Splices k All rails use internal splices for seamless connections. • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits wok Mount MIs or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training Earn free continuing education creditC;%" while learning more about our systems. ae -- t o to lro� iRiira$j� cx)i nftxainirig whe 9nl;e-0jUl (OL/LL/LL) Z'L'ZL OS Z 1 Z a6ed j7LOZ ',,,OZ aunt f� Jaaup6u3 �1e1s n!-1 pJemoH oul 'VN saolniaS 6ullsal >la;lalul :9184 bWz ',,,OZ ounr ale(] aJnleu6ls :aanleu6iS :911!1 pea -1 weal buuaaulbu3 :91111 :Aq pamapna2l Pled 94P8b :Aq palaldwoO •silJew uo!leogp iao i alialul Aue 10 asn a41 Jot uo!lezuo4lne luasaJdaJ lou saop poda�j Jaga-1 s!41 `alou aseald •pau6psJapun a41 loeluoo of alelpsa4 lou op aseald `Navalul Aq paJa}yo saovuas Ja410 a41 10 Aue Jo `llodaJ s141 up pau!eluoo sllnsaJ a41 6uppJebaJ suo!lsanb Aue aie aJa41 11 VSS£OLLOLJ•oN loafoJd Mapalul Aq paJanoo uopleniena 94110 umpod s141 salaldwoo 1JodaJ Jallal s141 x!11ns a Aq pamollol aq Aew Jagwnu :Jed JalJanu! 'Jagwnu Aue si xx-xxxxx aaa4m 4a1pmS Ala1eS JalJanup a41 ul pa11elsu! s! xx-4Si1-00MS 1!1 JO]Jed s! 4:)'4m,,x -xxxxx-g'-IJNI„ palagel algea umopin4s p!deJ @SHMioS ay1 ua4m Sf1XOZ3S / Sf1H0T3S / Sf1>163S 0 1 LOZ 'y,OZ aunt L00-jHot,gSEOLLOL 1Joday Jal;a-1 SJa3.Janu1 4d-£ P1-1 s91601ou4oal 96p3JeloS anlleutlo;ul (0L/LL/L L) Z'L'ZL OS .Oul 'HN s93lnJaS 6ulls8l Nal.a;ul �a3.1a21>! K�l.laXui x�}aa3.1i slaztatup fal.alul �at�:a♦lyy�+f 'we'6oid uo.4m4pao >a11alul ue lapun uaaq lana sey to si aoinias in lonpoid 'leualew ayl le Lp Alclwi lou saop ]Iasi! Aq liodai siyl 'palsal aldwes ay1 Rluo luenalaJ ais liodai slyl ul sllnsai ]sal pue suogeniasgo aqj '>lallalul Aq 6uppm ul panadde aq,siy lsnw aowas to lonpoid 'leualew palsal OLP ;0 luawasgianpe to ales aq1 Jo; s>uew sA;o Gun to aweu >lalialul ayl;o asn Auy Rlaigua sl! ul 6luo uayl pue ylodai siyl;o uognqulsip to 6ukloo liwiad of pazuoylne si luago ayl /No 'liodai siul;o asn aLp Aq pauoise000 a6ewep to asuadxa'ssol Rue J0j'luawaai6e ayi qjm aouepi000e ui lump ayl of mg lal{10 'Ryed ,Cue of lggigeil ou sawnsse >lapalul juaweei6e ail] ;o suogipuoo pue suual ay1 al paUwg ale Allllgeg pue Ap!q!suodsa s,Havalul 7uago sli pue >lallalul uaaMlag luawaai6e ayl of luensind papinoid st pue luago s,>layalui;o asn anlsnr>xa aul lo; sl Vodai sly] Z;o L a6ed x!}}ns a Aq pamollo; aq Aew Jagwnu lied JalJanu! ` aagwnu Aue s! xx-xxxxx aaa4m 4a1!mS A1a1eS JalJanu! @41 111 pa1lelsu! s! xx-aSi1-00MS 1!j 10 lied s! 4a!4m „x-xxxxx-gJ-IJN,, palagel algea umop;ngs p!deJ aSp31eloS 941 ua4m Sfl-dOOVTT3S / Sfl-t/0000T3S / Sfl-VO09L3S / Sfl-VO0093S / Sfl-VOOOS3S / Sfl-VOOSE3S / Sfl-`d000£3S 0 sJalJanu14d-T OS£=000 '00£=uuu 'SOB=www of do wnw!xew a of 6-0'aagwnu Aue s! 000 'uuu 'www aaa4m 'OOS=zzz `OS£=AAA'00£=xxx of do wnw!xew a 016-0 'Jagwnu Aue s! zzz 'AAA 'xxx aaa4m '000d pue uuud 'wwwd 'zzzd 'AAAd 'xxxd 0 'OOL=aaa '009=PPP 'OOS=aaa OS£=qqq 100£=eee oldn wnw!xew a of 6-0 'aagwnu Aue s! aaa 'ppp 'aaa 'qqq 'eee aaagm'aaad 'PPPd 'aaad 'gggd 'eeed 0 6-0 'aagwnu Aue s! xxx aaa4m `n3-XXX-dO 'nl-XXX-dO 'nW-XXX-dO 'nl-XXX-dO 0 •sJagwnu pue sJallal Jno110 uo!1eu!gwoa Aue si zzzz pue `131 Jo gob aq pinoa AAA `OS£ = xxx aaa4m an1eA wnwpxew a of do '6-0 'aagwnu Aue si xxx aaagm'zzzz-AAA-xxxgd 0 :sJazpw1ldo Jamod • :slonpoJd algeo!lddy •uo!le!1!u! umop;n4s p!deJ 10 spuooes 01 u!41pm saJadwe -110A 017Z Pue s11oA OC ue4; aJow lou 01 p91!w11 WE sJolonpuo0 p911oJluo0 le41 paq!JaA se4 auop 6u!;sa1941 •molaq pals!I sJagwnu lied 4l!m sJallanu! pue sJazmwp;do 10 6U11SISu0O suoplepelsup sJanoo uo!1enlen9 941 't,L0Z/LL/90 uo leuosJad �alia1u1 Aq ssaul!m pue -13d2iSl 'NOHVHS`dH aOH 1S 4seJ8H,eH 9'M sa!6oiou40a1 96P3Je1oS le wJopad aJam;sel umopings ppde�l •t,WZ/04/90 Pa1eP 69ti17fi9009 along pau6!s Aq pazuoglne sem uo11e611sanu1 s141 umopin ys plde� �o� luauJa�lnbaJ JV069 uogoaS 'bLOZ `apoO 09/0a13 leuol;eN :spJepuels bu!mollol a41 uj pau!eluoo sluawaJnnbei a41 of slonpoJd palsg molaq a41 10 sllnsaJ bugsal a41 sluasaJdej Japal s!41 `;sapy JIaW •JW Jeaa sluawaJnnba�j umopin4S p!deH O3N of slonpoJd a6p3Je1oS 10 uo1lenleA3 -l13 :loafgnS woo•a6paJelos@e•.naw :11ewe OZ99'LS6.6•ZL6+ :4d t,SS£OL LO LO 'ON loafoJd 100-1'HOV99£OL 10 L 'ON pod98 Japan woo,> gpalurmmm L696 -99L (L09) .allwlsoej L LL9-E9L (L09) :auoudalal S40EL A 'Puel;loO L L a;no�j Sn ME 13VHSl 'NOHVHSVH GOH 1S 4seJeH,8H 9 PI -1 s91601ou43a1 a6P3Je1oS lsapy JIaW 'ivy t,LOZ 'OZ aunt CLASSIFICATION Constructional Data Report (CDR) 1.0 Reference and Address Report Number 101541132LAX-002 -F-Original 22 -May -2 14 Revised: 15 -Jan -2016 Standard(s) UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Applicant IronRidge, Inc. Manufacturer 1 IronRidge, Inc. Address 1495 Zephyr Ave Hayward, CA 94544 Address 1495 Zephyr Ave Hayward, CA 94544 Country USA Country USA Contact Yann Schwarz Contact Jim Norsworthy OrDave Taggart Phone (800) 227-9523 (510) 225-0973 Phone (707) 363-3025 (800) 227-9523 FAX (707) 459-1833 FAX (510) 225-0975 Email yschwarz(abironridge.com Email jnorsworthy(a-)iron ridge. comidtaggart@ironridge.com Manufacturer 2 Precision Die 8t Stamping, Inc. Address 1704 W. 10th Street Tempe, AZ 85281 Country USA Contact Andy Frola Phone (480) 967-2038 FAX (480) 829-0838 Email andy(a-_)precisiondie.com Page 1 of 86 Ileis tcpprt is ;pr the eKLansive use of inteltek's Client ane] is provided pursuant to ane cigreenveik between IntEitek and Is Cent intertek's fesprxtsibiiity and IrdWy are ionated to tilt' Wrens and Conditihns of the .a roomwL Intermit as.5tflt m no liability to any party, otner than to the client in 2eeordanoe with the agrr tgr Writ; tar any loss, kfrq rLSre rx danlap 4x ut J sku tt by the tfsQ esf t'ds nRfX9I. f}niy 1ttFa C IL ant, is Rant rsri ati is {bHrrtt t colayiny nr d s tr button at Ytiit r atxxn sated then only 1n rte entirety. Any use of the tiitetek name or one of its niers for the sNe or ad`tefternent of the te.Bted matenaf, product or service Must ftr*t be approwod in writing by IntB0t0k, Tho obGi; r WJons a" toM results to Ibis report Ora roWw ant onty to Nie tarnplp Wod This raW by itself pons not imply INK tbst materia(, P,"xt, or servk* is rx host ever beeo wit1w an kitedek caat6firipiori r"ram Report No. 101 541132LAX-002 IronRidge, Inc. Page 2 of 86 Issued: 22 -May -2014 Revised: 15 -Jan -2016 2.0 Product Description Product XR Rails with Integrated Grounding. Brand name IronRidge Roof Mount The product covered by this report is the IronRidge Rails with Integrated Grounding solar roof mounting system. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized aluminum rails that are roof mounted using aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XR100 and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to extend their length. A grounding strap and stainless steel hardware are required for penetrating the anodized coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic modules to the system. The End Clamps are not used as a grounding means. The Grounding Mid Clamps are installed onto the module frame by using a 18-8 stainless steel serrated T -Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a Description specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of the photovoltaic modules frame and rail to contact the metal, creating a bonded connection from module to module and module to rail. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code. including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes. An entire array, regardless of size, is grounded via one grounding lug. The WEEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot using stainless steel hex bolt or T -Bolt, flat washer, split lock washer, and nut, tightened to manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 6 AWG. The Titan Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel T -bolt, k -lock nut, star washer, and machine screw. The Titan Grounding Lug is intended for use with one solid or stranded copper wire, conductor size 14 AWG though 4 AWG. Models IR XR followed by 4 Alphanumeric Characters Model Similarity N/A Fuse Rating: 20 A Fire Class Resistance Rating: - Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. Ratings - Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. - Class A for Steep Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1 and Type 2, Listed Photovoltaic Module. - Class A for Low Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. city 01 Wheat Ridge wilding Division ED 16.3.15 (1 -Jan -13) Mandatory i CITY OFWHEAT RIDGE ��P�Building `Inspection Division (303) 234-5933 Inspection line '(303) 235-2855 Office • (303) 237-8929 Fax INSPECP9N NOTICE p 31f) - -cc /Y1 e 4c - r -e �Gv,,- Inspection Type: y 0 3- Job Address: '�-1 -7 _7 3 Foe r -e C4 - Permit Number: a o i g o a -7 y S ❑ No one available for inspection: Ti AM/PM Re -Inspection required: Yes,,* When corrections have been made, call for re -inspection at 303-234-5933 Date,/C° Insp'* f DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: E i l Q lt0Ji-_ Job Address: q � 7 -9 _ i'r` , , 6t Permit Number: - i O ❑ No one available for inspp, c)'Tpn: Time 1 AM/PM Re -Inspection required: /Yes/ No When corrections have been'fiiade, call for re -inspection at 303-234-5933 Datej ' f Inspector: DO NOT REMOVE THIS NOTICE ® A City of Wheat Ridge y � Residential Electric PERMIT - 201802748 PERMIT NO: 201802748 ISSUED: 10/15/2018 JOB ADDRESS: 4773 Everett Ct EXPIRES: 10/15/2019 JOB DESCRIPTION: Residential electric- 200 AMP service change. *** CONTACTS *** OWNER (303)420-1595 VAN ESSEN SETH SUB (303)400-4321 Edward Jueschke 021943 SJO Electric LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,500.00 FEES Total Valuation 0.00 Use Tax 52.50 Permit Fee 93.35 ** TOTAL ** 145.85 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2017 NEC. Subject to field inspection. "b y my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the le al owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisppe i further attest that I am leg�ally authorized to include all entiti s named within this document as parties to the work to be p`rtor hat a�lrk toe bertormed is disclosed in this docurr�erand/oryts' accorp�ianyin�. approved plans and specifications. Slgnat6reoT—OWNER car/CONTRACTOR (Circleone) Dhte ' to, 1. This permit was issue ased on the information provided in the permit application and accompanyingpplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, anew permit maybe required to be obtained. Issuance of anew permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Di n. 6_ The!, s ince or oran of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any ap p le de ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY City of Wheat P..,jdge COMMUNITy DEVELOI'ML•N I Building & Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: PlanlPermit # Plan Review Fee. Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: `-! `1� 13 Uypeyo_4 C+ Property Owner (please prim: �1)QN tr- Vpp1Q lu'ffl Phone: W�) S w4 -�q 31 Property Owner Email; Mailing Address: (if different than property address) Address: 83 City, State, Zip:1)QDV,(— C C) gQ�) N Architect/Engineer: Architect/Engineer E-mail: Contractor: Phone: Contractors City License #: Phone: L(Cv(A (, Contractor E-mail Address: Sub Contractors:, , Electrical: al: �1' �', WA Plumbing: Mechanical: W.R. City License # �a C� l 1'3 W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ,ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 9(_,�) 4m 'It5 (C -t CAS . Sq. Ft./LF Amps Btu's Squares Gallons Other Project Valuje`: (Contract value or the cost of all materials and labor included in the entire project) +�l/t J $ � OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNED (CONTRACTOR) or (AUTHORIZED REPRE A'T ) of (OWNED (CONTRACTOR) PRINTNAME- -- S C.1"SCA- SIGNATURE: DATE: DEPARTMENf USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required Building Division Valuation: $