Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutWSP-16-05City of
Wheat�iclge
7500 West 29th Avenue
Wheat Ridge, Colorado 80033
Ph 303.235.2846 Fax 303.235.2857
Approval of Site Plan
The Fruitdale Lofts Site Plan for the redevelopment of 16 residential units on property located at
10803 W. 44th Avenue (Case No. WSP-16-05 / Fruitdale Lofts) is hereby approved for the
following reason:
The site plan complies with the applicable zoning regulations in Chapter 26 of the Wheat
Ridge Code of Laws.
and with the following conditions:
1. The northern portion of the property shall be appropriately maintained to establish the
proposed native seed, including but not limited to periodic mowing, chemical and/or
mechanical weed control, supplemental watering, and supplemental seeding.
2. Approval of drainage facilities shall be obtained from the Public Works Department as part
of the building permit review.
�enneth Johnstone, AIC
Community Developme Director
Da
WILSON
&COMPANY
1675 Broadway, Ste. 200
Denver, CO 80202
303-297-2976 phone
303-297-2693 fax
TECHNICAL MEMORANDUM
Fruitdale Lofts (WSP-16-05)
Wilson & Company Project No.: 16-600-422-00
December 15, 2016
Regarding: Final Drainage Report (Discussion)
Fruitdale Lofts
Introduction
CITY OF WHEAT RIDGE
PUBLIC WORKS, ENGINEERING
APPROVED FOR:
jd DRAINAGE 0 SIDEWALK
O CURB & GUTTER O STREET
0 MISCELLANEOUS O PLAT
COMMENT Site Drainage and Water Quality
1 211 512 01 6
CIVIL ENGINEER DATE
SUBJECT TO FIELD INSPECTIONS
(Prepared by AJS)
(Reviewed by KMG/JMG)
This technical memorandum is intended to support the onsite development of the proposed
Fruitdale Lofts project. This tecluiical memorandum has been prepared by Wilson & Company and
is submitted, in lieu of a Drainage Report, for review and approval by the City of Wheat Ridge on
behalf of Hartman Ely Investments, LLC.
The site is an existing elementary school that is being redeveloped into apartment living. The
proposed site is situated on 1.44 acres and is located within a block that is bolmd by a residential
area (North), Fruitdale Preschool (East), West 44t" Avenue (South), and an auto body shop business
(West). A vicinity map showing the approximate site location has been included within this
memorandum.
The proposed redevelopment of the 1.44 acre parcel consists of two existing structures. One
building, located on the northern half of the property, will consist of 15 living units and a smaller
building, located at the southwestern portion, will consist of one living unit. The southern portion
of the property will be predominantly paved asphalt to be used for site parking while the northern
portion of the property will be used for solar panel placement. The existing Frutidale school
building is situated centrally between the northern and southern halves of the site. Refer to the
attached site plan for more information.
CITY OF WHEAT RIDGE
PUBLIC WORKS
DATE 12/15/2016
RECEIVED 12/15/2016
2nd Submittal
ISI HIGHER
MISON Page 2
&COMPANY
Existing and Proposed Drainage Conditions:
Historically, the site drains to the east, where flows are captured and treated by the existing
Fruitdale Preschool detention facility as described by the Final Drainage Report for the Fruitdale
Preschool prepared by Anderson and Hastings Consultants, Inc. on April 2nd, 2007. The intent of the
proposed project is to match the existing drainage patterns as closely as possible. Minor alterations
from the existing drainage patterns are expected due to the limited slope across the site from west to
east. The proposed grading will ensure that stormwater runoff is directed away from the existing
structures and provide protection from ponding stormwater.
As the proposed project is a redevelopment of an existing site, the improvements required will
mainly consist of reconfiguring the asphalt parking lot, adding additional sidewalks, removing a
dirt benn, and installing proposed utilities. The existing structures on-site are to remain and be
converted into apartment living space. The complete disturbance required for this development will
be 0.93 acres and will not require water quality or a Stormwater Management Plan (SWMP) due to
the area of disturbance being less than one acre. An exhibit entitled "Area of Disturbance Exhibit"
has been included within this memorandum.
For the purposes of the drainage analysis and discussion, the proposed site has been analyzed as
one major basin to compare the composite imperviousness for pre -developed and developed
conditions. Each major basin has been further divided into individual basins for a more critical
analysis of the site. Four exhibits (EXB-A, EXB-B, EXB-D, and EXB-E) have been attached to this
technical memorandum summarizing our findings and have further been summarized below.
Existing Basin:
The existing site is divided into four (4) existing sub -basins as described below:
Sub -basin EX1 consists of a portion of unoccupied land located on the northern half of the site. The
basin is approximately 0.67 acres and has an imperviousness of 2.0%. All runoff from this portion of
the site is directed east through overland flow into the adjacent property.
Sub -basin EX2 consists of an area to the north of the existing school building that is comprised of
small area of concrete sidewalk and a larger area of native grasses. The basin is approximately 0.380
acres and has an imperviousness of 3.89/o. All runoff produced within this basin is conveyed through
overland flow and into an area inlet. The flows then continue through PVC piping to a pond located
adjacent to the property.
Sub -basin EX3 consists of the main existing school structure located in the central portion of the site.
The basin is approximately 0.271 acres and has an imperviousness of 88.0%. The majority of the
WILSON
&COMPANY
Page 3
runoff produced within this basin is collected via rooftop drains and discharged to the adjacent
property.
Sub -basin EX4 consist of the southern half of the site, including an existing structure, parking lot,
and sidewalks. The basin is approximately 0.722 acres and has imperviousness of 67.2%. All runoff
generated within this basin is conveyed through overland flow, discharging at the east property line
and into an existing concrete pan.
The overall existing site imperviousness is currently 51.4% (see EXB-A provided in the attachments)
and is comprised of 19,478 SF of asphalt paving, 12,657 SF of rooftop, 822 SF of concrete paving and
29,754 SF acres of landscaping.
Proposed Basin:
The proposed site is divided into nine (9) proposed sub -basins as described below:
Sub -basin PRI consists of mainly native grasses and is located on the northeast corner of the
property. The basin is approximately 0.067 acres and has an imperviousness of 2.0%. All runoff
within this basin will be conveyed through overland flow to the adjacent property line, matching
historic conditions.
Sub -basin PR2 consists of the area located to the north of the existing school structure and is
comprised mainly of native, vacant land and small portion of concrete sidewalk. The basin is
approximately 0.380 acres and has an imperviousness of 9.0%. All runoff produced within this basin
is conveyed through overland flow and into an area inlet. The flow will then continue through PVC
piping to a pond located adjacent to the property, matching historic conditions.
Sub -basin PR3 consist of the existing main school structure located in the central portion of the site.
The basin is approximately 0.271 acres and has an imperviousness of 89.2%. The majority of the
runoff produced within this basin will be collected via roof drains and discharge to the adjacent
property, matching historic conditions.
Sub -basin PR4 consist of a small area of landscape and sidewalk located in the eastern central
portion of the site. The basin is approximately 0.14 acres and has an imperviousness of 19.6%.
Runoff produced within this basin will freely flow offsite through overland flow.
Sub -basin PR5 consists of an area located in front of the main school building. The basin is
comprised of a small localized depression, existing trees, and proposed sidewalks. The basin is
approximately 0.072 acres and has an imperviousness of 23.3%. Runoff generated within this site
will collect within the localized depression and overtop through a sidewalk chase. The runoff will
continue through a concrete pan and ultimately into West 4411, Street.
wilsom Page 4
&COMPANY
Sub -basil PR6 consists of an area located in between the main school building and the adjacent
smaller structure. n-te basin is comprised of a small localized depression, with concrete sidewalks,
landscaping, and packed gravel pathways. The basin is approximately 0.107 acres and has gun
imperviousness of 17.4%. Runoff generated within this basin will be collected within the localized
depression and release through overland flow into the adjacent property as well as through a
sidewalk chase and into a concrete pan. Flows that release through the sidewalk chase will be
collected via a concrete pan in the parking lot and into W 44th Street via a sidewalk chase.
Sub -basin PR7 consists of the proposed asphalt parking lot and concrete sidewalks. The basin is
approximately 0.446 acres and has an imperviousness of 85.5%. Runoff generated within this basin
will be collected via a concrete pan and into West 4411, Avenue via a sidewalk chase.
Sub -basin PR8 consists of a small portion of concrete sidewalk and landscaping that drains freely
offsite. The basin is approximately 0.06 acres and has an imperviousness of 47.0%. Runoff generated
within this basin will flow freely to the southwest corner of the site and into West 441h Street.
Sub -basin PR8 consist of an area along West 44th Street that flows freely offsite. The basin is
approximately 0.023 acres and has an imperviousness of 25.2%. Runoff generated within this basin
will be conveyed through overland flow and into the existing curb and gutter along West 4411, Street.
The proposed site imperviousness is 50.8% (see EXB-B provided in the attachments) and consists of
12,022 SF of asphalt paving, 12,597 SF of rooftop, 568 SF of packed gravel, 8,507 SF of concrete
paving, and 29,015 SF of landscaping.
For both existing and proposed conditions, the calculated 100 -year runoff coefficient is 0.74. It was
thus determined that during the 100 -year event, the overall site produces 6.94 cfs for the existing
conditions and 7.08 cfs for the proposed conditions. A summary of the calculated flows for both the
5 -year event and 100 -year event can be found below.
Table 1: Existing Peak Flow Summary
Table 2: Provosed Peak Flow Summary
100 -year flow
Sub -Basin
Area (acre)
5 -year flow (cfs)
(cfs)
School
1.44
1 2.44
6.94
Table 2: Provosed Peak Flow Summary
100 -year flow
Sub -Basin
Area (acre)
5 -year flow (cfs)
(cfs)
School
1.44
2.47
7.08
WILSON Page 5
&COMPANY
The proposed flows will match the historic drainage patterns for the north half of the site, while the
south half of the site will be redirected through a concrete pan and be released via a sidewalk chase
into West 441h Avenue. Altering the historic drainage pattern for the southern portion of the site is
required due to the limited fall across the site from west to east. As a result of the limited slope, two
localized depressions will also be required in Basins PR5 and PR6 and will act as BMP to treat the
stormwater runoff through infiltration. Basin PR5 has a maximum ponding depth of 0.6" (Total
Volume = 9.18 CF) and Basin PR6 has a maximum ponding depth of 5.4" (Total Volume =135.81
CF). Each localized depression has been equipped with a sidewalk chase spillway that will ensure
that ponding water does not exceed the proposed depths.
As there is minimal difference between the proposed and existing site imperviousness, the 100 -year
flow rates, and the 100 -year runoff coefficients, we propose that the requirement of providing 5 -year
and 100 -year volume detention and water quality treatment prior to releasing storm water discharge
be waived.
Conclusion:
The significant conclusions and results from the final drainage analysis for the Fruitdale Lofts project
are:
1. This drainage report has been prepared in accordance with the City Wheat Ridge Site Drainage
Requirements and the Urban Drainage Flood Control District's Storm Drainage Criteria
Manual.
2. Based on minimal difference in site imperviousness values between proposed and existing
conditions, we have determined that the proposed site conditions closely matched existing,
therefore should have minimal to no impacts to downstream infrastructure.
3. The calculated 100 -year runoff coefficient for the existing and proposed site conditions is 0.74.
This equates to a total site imperviousness of 50.8%, which is slightly lower that of the existing
site imperviousness of 51.4%.
4. Due to minimal impacts on site conditions, the future development shall match existing
drainage patterns.
5. Two localized depressions in Basun PR5 and PR6 will be required to achieve positive drainage
across the site and will act as BMPs for the proposed project.
QP�p LICEN�
O . •••....•�
Oma' : `PANE 00%
U o �,,y`1�►��10 O��
q.7�'46 Z
A •
y
WILSON Page 6
&COMPANY
References:
1. City of Wheat Ridge Site Drainage Requirements, Revised October 2014.
2. Urban Storm Drainage Criteria Manual, Vols. I, II, III; 2016, Urban Drainage and Flood Control
District.
Attachments: Vicnnity Map
Proposed Site Plan (for reference only)
Fruitdale Lofts — Existing Imperviousness Map
Fruitdale Lofts — Proposed Imperviousness Map
Fruitdale Lofts — Existing Site Hydrology
Fruitdale Lofts — Proposed Site Hydrology
Fruitdale Lofts — Nyoplast Drop In Area Inlet Sizing Chart
Fruitdale Lofts — Sidewalk Chase Sizing Calculations
LL.
Zi
N
Z�
O10
O O
OZ
JOU
U
QQU'
Q
C
(n
L
a �
oU
LL._3
CJ
m
w
Kipling St
Garland St N
Q
earl-�•n1 St
z
Q
t
15 pue11Cl11 N u
� Q
O O
i
8
crz
a
OsA St U)
z ~
— S
— W i
d W 4>
H =
V
R,
a
;
CL
h
He�2 Cc
Ince,^_c-ndencc Ct
It'
Q
en
Q
3
Newman St
d
C �
Oak St L O
m G
}
Rout; 5
N
O O
U
C
(n
a �
Kipling St
CJ
m
w
Kipling St
u
4
m �
z
a
h � L
a
`
c
4
O O
t u
R
8
crz
a
b
cr z
O
y
1D `'
~ C)
z
Moore St
OsA St U)
z ~
— S
— W i
d W 4>
H =
V
R,
a
;
CL
h
He�2 Cc
Ince,^_c-ndencc Ct
It'
Q
en
Q
3
Newman St
d
C �
Oak St L O
m G
}
Rout; 5
am 00'10(31d IVDHM'inN3AV q4VP maze
} t ( \ S]O]]]VO]ndj
{ q !| q011S 3Nl Vd ]OOH aS 3 ¥Olnaj
Cl) .
( 2 \
§ !!! U) § ! !
o � | 2,R ` ! ||| Z
§ | _ C/)
( §\ \ / /\ ) — ■� •
Iu
n ,>!. § ;� ON, § -
lZ-- -) !§! .
j + 2z 44 2 & §; § §
§
:I � /..: § ° § .
e
■
/
)
N
O j
N ~
d
a0
��m
N
2 co
Ld
Q p p
03g
0 W
d w
w I
Q
aeU
X
LU
"s
6
E � E aS
"
J
3 �
_
e a °idle
III
e
�
s
I
i
JI
I
�f
—1' 3
QN
Ij.I i
1
�L
�J
�
lob
\{(
B//ƒ
w
/
\}QF-\ƒ
(
w
§§3:LU
�E
j
�
lob
,
�E
\§
■
2(|
ass
sit
!
;'!p
=MOM
! d`y.
e!
� �
!|
\!j
�!
Bg!
�
lob
E
N
n-
y�o•oo�...
$5 555595°
UJ
w:co��•
o
w
w m
LL J
06,S�y+� •
=
SSG9CAA
Q< o
�3K
0
OCL Zx
W
O
��
d EEE€I€esb
LL.
p W
n 6 i1
5=ea-
ge. I"6T
�� ea55sa sls
o I^
aasp..2
0
a
�CEB
w
Bo�BeeeS
O
c �
srtseKe6�ssrt
oo;�
t�
�
WU'I X
V u of'ep
y,
S S kkeoeg a
` R
Z
B
s°�a'P9;d
sola
aEd e8$Ss•e5
a
w
w �
3
f
I
s/ejd/
feSf6e� 'S
wm
a
sa �s
l�e63SSe59d5
W �
�>
f
; moo 8
Vami
O
a -
�
O�
i
+
e
yy
.�
/ asa
/
Ia
q
In.'.�;
a
4'
a
I
a
>
1
Ir
ELn
x
V
s4
=Zi
Project Name: Fruitdale Lofts
Job Number: 16-600-422-00
Subject: Existing Hydrologic Calculations
Date: 12/13/2016
By:
Intensity - Duration - Frequency Curves
Greeley
2 -Yr 5 -Yr 10 -Yr 50 -Yr 100 -Yr
1 -Hr Point Rainfall 0.95 1.34 1.55 2.25 2.57
Time 2 -Yr Design
(min) Storm
5 -Yr Design
Storm
10 -Yr Design
Storm
50 -Yr Design
Storm
100 -Yr
Design Storm
5 3.22
4.55
5.26
7.63
8.72
6 3.06
4.32
5.00
7.25
8.29
7 2.92
4.12
4.76
6.92
7.90
8 2.79
3.94
4.56
6.61
7.55
9 2.68
3.77
4.37
6.34
7.24
10 2.57
3.63
4.19
6.09
6.95
11 2.47
3.49
4.04
5.86
6.69
12 2.38
3.36
3.89
5.65
6.45
13 2.30
3.25
3.76
5.45
6.23
14 2.23
3.14
3.63
5.27
6.02
15 2.16
3.04
3.52
5.11
5.83
16 2.09
2.95
3.41
4.95
5.66
17 2.03
2.86
3.31
4.81
5.49
18 1.97
2.78
3.22
4.67
5.34
19 1.92
2.71
3.13
4.55
5.19
20 1.87
2.64
3.05
4.43
5.06
21 1.82
2.57
2.97
4.31
4.93
22 1.78
2.51
2.90
4.21
4.81
23 1.73
2.45
2.83
4.11
4.69
24 1.69
2.39
2.76
4.01
4.58
25 1.66
2.34
2.70
3.92
4.48
26 1.62
2.28
2.64
3.84
4.38
27 1.58
2.24
2.59
3.75
4.29
28 1.55
2.19
2.53
3.68
4.20
29 1.52
2.14
2.48
3.60
4.11
30 1.49
2.10
2.43
3.53
4.03
31 1.46
2.06
2.39
3.46
3.95
32 1.43
2.02
2.34
3.40
3.88
33 1.41
1.99
2.30
3.34
3.81
34 1.38
1.95
2.26
3.28
3.74
35 1.36
1.92
2.22
3.22
3.68
36 1.34
1.88
2.18
3.16
3.61
37 1.31
1.85
2.14
3.11
3.55
38 1.29
1.82
2.11
3.06
3.49
39 1.27
1.79
2.07
3.01
3.44
40 1.25
1.76
2.04
2.96
3.38
41 1.23
1.74
2.01
2.92
3.33
42 1.21
1.71
1.98
2.87
3.28
43 1.19
1.69
1.95
2.83
3.23
44 1.18
1.66
1.92
2.79
3.19
45 1.16
1.64
1.89
2.75
3.14
46 1.14
1.61
1.87
2.71
3.10
47 1.13
1.59
1.84
2.67
3.05
48 1.11
1.57
1.82
2.64
3.01
49 1.10
1.55
1.79
2.60
2.97
50 1.08
1.53
1.77
2.57
2.93
51 1.07
1.51
1.75
2.53
2.89
52 1.06
1.49
1.72
2.50
2.86
53 1.04
1.47
1.70
2.47
2.82
54 1.03
1.45
1.68
2.44
2.79
55 1.02
1.44
1.66
2.41
2.75
56 1.01
1.42
1.64
2.38
2.72
57 0.99
1.40
1.62
2.35
2.69
58 0.98
1.39
1.60
2.33
2.66
59 0.97
1.37
1.58
2.30
2.63
60 0.96
1.35
1.57
2.27
2.60
O 01) CO (D L M N �—
(,inoy/sayoui) /.4isua;ul
m
O
(D
Lo
LO
O
LO
LO
IT
O
It
LO
M
m
3
c
M E
LO
N
O
N
Ln
O
:s
I '
I
a
I
e
€ o o € €
N N N
Q N N
I I I I
•
'
I
•
'
'
�
I
I
,
I
i'
t
/
e //
It
O 01) CO (D L M N �—
(,inoy/sayoui) /.4isua;ul
m
O
(D
Lo
LO
O
LO
LO
IT
O
It
LO
M
m
3
c
M E
LO
N
O
N
Ln
O
:s
�I r IW I r I Q l
Z
W
U
LL
LL
W
0
U
LL
LL
O
Z
D
d .. w
W
� � F
Z E .. O
iL
3 U
Z °' m 2
-00 a U
"COO m
IL
C
T
N
N
T
V O
O
d �
O
C
0
o0
0
r%
0
O
U
O N
M
u)
o
O
7 p
d
O
O
O
O
O
.y
O
{0
n
W
N
O
£ N
E
O
O
O
O
0
0
0
0
0
U
U)
r C
o
0
0
O
G O_
O
O
O
N
£O
N
M
Ca
CO
w
1n
U
Y
U
o
0
o
e
e
N
L
0
0
0
0
0
U
000
0
0
0
0
0
0
0
0
0
0
0
C
p
0
W
N
M
V
N .. ..........
w N N
coN
t0
J Q N
O
C
o
0
0
C
0
> 0
O
LO
NCO
M
a
O
O
a�
C (0 N
N C O
N
d
O
d
o
e
o
o
e
N 0
O
O
O
O
O
Y
�p U
O
O
O
O
O
N> O d
0
0
0
0
C.
C
R
J
cl
O
O
m
M
N
O
QU
0
0
0
0
0
c0
0
0
0
C 0
0
0
0
N
N U
o
0
o
V
V
a Q m
o
0
0
0
0
<0
n
Q N
r
tD
O
aD
I�
N
N
H v
c_
U
N
M
V
A
W
W
u
W
W
F
'n
u
O
C
0
C N
N r
X; a
w
F2
z
0
z
LU
0
z
0
0
LL
0
LU
F
d .
E `m
z E ..
ami Z ci
.0 .0— �+
`n
ainom
a
O
qW
G
J
a
Z
0
1-
Q
LL
LL
O
Z
a'
Q
W
}
0
O
2
H
W
J
Q
Z
O
F-
a
LL
w xINIQI
LL
LL
O
Z
Gi D
E m
m
Z
0 u W
y Z d
O+- o
0 7 m �. O
a -)(nam
m
O
z
W
LL
LL
W
0
U
LL
LL
O
z
D
d W
z E .. o
U
z d
d m c r2
LL`ni
�O
z
O
H
0:
H
z
w
U
z
O
V
LL
O
W
2
H
a>
E
A
z
AD
0
a`
0
0
N
N
O
0
0
m
0
O
2
F -
w
J
Q
z
O
H
a
LL
LL
O
z
D
w
Z m a) W
0
-) co in m
0
O
CW
L
J
Q
z
O
i
1�
LL —
a161
—
7
LL
O
z
m �
E
ca �
Z
'+ v W
Z m
ami
p r c
a`�i
R
t
U
w
R
G.
R
U
N
r-
0) N
V
C
G.
O
cc
U)
R
G.
O
Z
p In O
M M
O O O
In O
N Cl!
O O
(rp) /4ioedeo
N
T
O
O
O
O
In
1b
O
O
O
O
1n
t•
O
O
O
O
O
m
N
N N
1b m O
O
CV
ID
Ln
N
O O0)
o
r/� Q C
0
CD
CD
v Co Cu
1;
CD
O
L
m v U
• U
ca
Y7
O
j N d
O
o
_O
FEW m c
In
c
c
0
> n
-
o
In
O
o
O
co
00
0O
cD
o
v
o
In O In O
to
ao
LO
M
O
O
M
O
Ln
N
O
O
N
O
O
_O
O
In
O
O
O
O
O
In O In O
O O
O O O O
Channel Report
Hydraflow Express Extension for Autodesk@ AutoCADO Civil 3130 by Autodesk, Inc.
Sidwalk Chase -
SC2 (TYP.)
Rectangular
Bottom Width (ft)
= 1.83
Total Depth (ft)
= 0.33
Invert Elev (ft)
= 5385.43
Slope (%)
= 0.50
N -Value
= 0.013
Calculations
Compute by:
Known Depth
Known Depth (ft)
= 0.33
Elev (ft)
5386.00
v
Section
5385.75
5385.50
5385.25
5385.00
in
Highlighted
Depth (ft)
Q (cfs)
Area (sqft)
Velocity (ft/s)
Wetted Perim (ft)
Crit Depth, Yc (ft)
Top Width (ft)
EGL (ft)
5 1 1.5 2
Reach (ft)
Wednesday, Oct 19 2016
= 0.33
= 1.897
= 0.60
= 3.14
= 2.49
= 0.33
= 1.83
= 0.48
2.5 3
Depth (ft)
0.57
0.32
0.07
-0.18
-0.43
sim
PROVIDE 10' WIDE GATE
W. 44TH PL
PLANTS ON EACH —
PATIO AS SHOWN ON
LANDSCAPE PLAN
EXISTING 6' CHAIN
LINK FENCE
4' SIDEWALK
PATIO @ UNIT
102 ENTRANCE
BICYCLE RACK
SOUTHWEST ENTRANCE
S FIRE ACCESS SETBACK
PATHWAY REFER TO
LANDSCAPE DRAWINGS
UNIT 100 ENTRANCE
PATIO
UTILITY EASEMENT TO
BE PROVIDED BY
SEPARATE DOCUMENT
R
TRANSFORMER
UTILITIES LOCATIONS
5 REFER TO CIVIL
,2 DRAWINGS f
I
I
I ❑
I (15 UNITS) FULLY SPRINKLED
I
11 77
I
I
NO SP INK S
PROPERTY LINE
SIDEWALK
PROVIDE 6' CHAIN LINK
FENCE AT
EAST AND NORTHOUS PROPERTY FRUITDALE LOFTS
LINES
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
1
.1 SOLAR PANELS - GROUND (SDP)
/8' = I -0"
�t APPROXIMATE
WEST 44TH AVENUE ti
PROVIDE 6' CHAIN LINK FENCE / GATE
PATHWAY ACCESS TO SOLAR FIELD
REFER TO LANDSCAPE DRAWINGS
PROVIDE 6' CHAIN LINK FENCE / GATE
NORTH ACCESSIBLE ENTRANCE
z
EAST ENTRANCE AND
•
5' 6'TRASH ENCLOSURE OF
COLORED CMU WITH
GALVANIZED METAL GATE
PROVIDE 6' CHAIN LINK FENCE
SOUTHEAST ENTRANCE
ACCESSIBLE PARKING SPACES
TEMPLE BUELL
MEMORIAL GARDEN
REFER LANDSCAPE
DRAWINGS
FIRE LANE SIGNAGE
FOR EXTERIOR LIGHTING
REFER TO LIGHTING
DRAWINGS
PARKING LOT LAYOUT
REFER TO CIVIL DRAWINGS
ELECTRIC VEHICLE CHARGING STATIONS
UTILITIES LOCATIONS
REFER TO CIVIL
DRAWINGS — — — _/I'\--
TERMINUS OF NEW 6' CHAIN LINK FENCE
NIrV ;';-f
T
3 VICINITY MAP
L�sYjI�RIONO��CRI�ION: 1
A PARCEL OF LAND SITUATED IN THE NORTH 112 OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF
THE 6TH PRINCIPAL MERIDIAN, COUNTY OF JEFFERSON, STATE OF COLORADO:
BEGINNING AT A POINT ON THE NORTH LINE OF THAT CERTAIN PROPERTY DESCRIBED IN RECEPTION NO.
86049897 BEING THE NORTHERLY RIGHT-OF-WAY LINE OF WEST 44TH AVENUE, SAID POINT ALSO LYING
642.56' NORTH OF THE CENTER OF SAID SECTION 21, SAID POINT BEING THE POINT OF BEGINNING; THENCE
N.89 3d'27W. ALONG SAID NORTH LINEA DISTANCE OF 99.01 FEET TO THE SOUTHERLY EXTENSION OF THE
WESTERLY LINE OF THAT CERTAIN PROPERTY DESCRIBED IN BOOK 9, PAGE 451; THENCE N.00 I& 35'W.
ALONG THE SAID WEST LINE AND ITS SOUTHERLY EXTENSION, A DISTANCE OF 261.17 FEET OF THE
NORTHWEST CORNER OF SAID PROPERTY, THENCE N. 89 41 ' 25" E. ALONG THE NORTH LINE OF SAID
PROPERTY, A DISTANCE OF 198.00 FEET TO THE NORTHEAST CORNER OF SAID PROPERTY; THENCES. 00 R!
35'E. ALONG THE EASTERLY LINE OF SAID PROPERTY, THENCE S. 0018'35"E. ALONG THE EASTERLY LINE OF
SAID PROPERTY AND ITS SOUTHERLY EXTENSION, A DISTANCE OF 263.36 FEET TO THE NORTH LINE OF THAT
CERTAIN PROPERTY DESCRIBED IN RECEPTION NO. 86049897: THENCE N.89 46'46'W. ALONG SAID NORTH
LINE, A DISTANCE OF 99.01 FEET TO THE POINT OF BEGINNING.
PROPERTY CONTAINS 51993.3 SQUARE FEET OR 1.19 ACRES MORE OR LESS.
THE BASIS OF BEARINGS FOR THE ABOVE DESCRIBED PARCEL OF LAND PLATTED ON FRUITDALE PATIO
HOMES TO BE N.00 09'23W. FROM THE EAST 1/4 OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF
THE 6TH P.M. TO THE NORTHEAST CORNER OF SAID SECTION, SAID EAST 114 BEING A 31 /4" BRASS CAP
AND POST SET IN RANGE BOX STAMPED LS 13212 PER MONUMENT RECORD AND THE NE CORNER BEING
STAMPED LS 13212 1984 PER THE MONUMENT RECORD. THIS BEARINGS NOTE AND ABOVE PROPERTY
DESCRIPTION TAKEN FROM CORRECTION BARGAIN AND SALE DEED RECEPTION k 2012I3EOD9.
GRAPHICGRAPHIC L�RZEND
PROPERTY LINE
----------------------
FIRE ACCESS
— — — — — — — — —
EXTERIOR LIGHT
EXTERIOR WALUFOOTPRINT OF
EXISTING BUILDINGS
ROOF LINE
FENCE...........................................
SOLAR PANEL
CONCRETE DRIVE OR PATIO
FIRE LANE ACCESS
PARKING LOT CURB
1/2D'=1'-0"
I�
1 1
0• 25'
LEVEL 0
3
OF EXISTING DRIVE CUTS REMOVE EXISTING CHAIN LINK FENCE 1.=p.-0'
SDP DRAWING INDEX
AD RATA
ADDRESS: 10803 W 44tH AVE
CASE HISTORY: -05
, MS -I b -0I, WZ-1-02
EXISTING ZONING:MU-N
PROPOSE LANDUSE:
MULT4FAMILY RESIDENTIAL
SITE DATA TABLE
IFP
GROSS BUILIDNG
TOTAL 40
THE BELOW SIGNED OWNERS), OR LEGALLY DESIGNATED AGENTIS) THEREOF,
DO HEREBY AGREE THAT THE PROPERTY LEGALLY DESCRIBED HEREON WILL BE
DEVELOPED IN ACCORDANCE WITH THE RESTRICTIONS AND CONDITIONS
CONTAINED IN THIS PLAN, AND AS MAY OTHERWISE BE REQUIRED BY LA W. 1
AWE) FURTHER RECOGNIZE THAT THE APPROVAL OF THIS SITE PLAN DOES NOT
CREATE A VESTED PROPERTY RIGHT. VESTED PROPERTY RIGHTS MAY ONLY ARISE
AND ACCRUE PURSUANT TO THE PROVISIONS OF SECTIONS 26-121 OF THE
WHEAT RIDGE CODE OF LAWS.
JIM HARTMAN
STATE OF COLORADO I
) SS
COUNIYOF-1:RSON I
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS
DAY OF . A.D. 20_ BY .
WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:
NOTARY PUBLIC
CSfY CERTIFICATIONY
APPROVED THIS DAY OF
BY THE CITY OF WHEAT RIDGE.
ATTEST
COMMUNITY DEVELOPMENT DIRECTOR
z
w
0
O
}U
r z
U �
o
LU
0
U)
K
N W
N Q
O �
0 2
ri O
2 a
a
M «� ♦-
N Y O N
W . dw
SUBMITTAL
ALu 0
Z Q
LLQ
O O -j O
LV O U
—1 O LLi
_ Ur
0 N
I— Lu
M Q Q
WU.
0 =_
LL
PRE PARED UNDERTHE
/J�\ FD URI D TILITY SUPERVISION OF:
/\/TL \ IN R ATION
THREE (3) BUSINESS DAYS
99 1
SECTION:27
RANGET.WNSI W
RANGE: BBW
PROJECT NO: 1527
50'BEFORE
YOU DIG CALL 811
(OR 1-800-922-1987)
SHEET
FRUITDALE LOFTS
r + -- + +-+.+ + -.+-� FRUITDALE LOFTS -
.............
+, I
SITE DEVELOPMENT PLAN I
I, ....... I . . + . ` . ` . ` . + . + . + . ` + < I NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL ERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
U .I 10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033 i
+ + + +
SCALE: 120 (FULL-SIZE) + + + + + + + + + + + + + +
40' + + + + + + + + + + + + + + + e I LEGEND
0' 10' 20' 1 . . . . . . . . . . . . . . +
. + . + . + . . GROUND -MOUNTED
SOLAR PANELS AREA
(.+.W.+.y.+. .+. . . . . . .
. + + +. + . . y y y .`
4+++++++ + +++++ + + + +LL+ + + PR BE -4
. . . . . PY LU- 1
PA QU-7 + + _ PY SU -1
PAVI-1 + + I)
1 CR CR- 1 -
PAQU. 17 MARE -9 -
MA RE- 11
PA VI- 1 DA BU- 4
PATIO
(RE: ARCHITECT)
PAVI-1—
PAVI- 1
PAVI- 1
PH OP- 4
PR MR -1—
CA AC -12
ARCO-4—
MA RD- 4
RU DA-2�
AR80R (ADD -ALT)
w/ (1) BENCH
MA YD- 4 —
LO RE- 3
(7) LANDSCAPE
BOULDER
JU CH-5—
MA RD- 3
RU DA -2
PE AT- 3
RO RE- 2
CH MI- 6
RO WB- 5 -�
RU DA- 3 —�
RO HA- 2'/
SP NI -5J/
TRANSFORMER J
(RE: ELEC) ULAC- 1
RO RE- 1
RO KO- 6
RO WH- 2
BETH -6
PA VI- 6
AR CO -6
RO KO- 4
INFORMATION PLAQUE
FRUITDALE LOFTS (RE: OWNER)
APARTMENT COMPLEX 1 6' BENCH
w BACK
EXISTING TREES
RO HA- 1 TO REMAIN (2)
PH OP- 2 PH OP- 2
MARE- 8 RO WB- 2
RO WH- 2RO RE-
/Ir RO KO -13
L CA AC- 12
1, —iffivi-I
CH -5
AT- 4
VI- 5
VI- 4
-ARC0.2
BE TH- 7
PE AT- 3
LANDSCAPE NOTES
PROVIDED
1. ALL PLANT MATERIALS SHALL BE TRUE TO TYPE, SIZE,
Srtclgnom -
SPECIES, QUALITY, AND FREE OF INJURY, BROKEN ROOT
05
BALLS, PESTS, AND DISEASES, AS WELL AS CONFORM TO
P
THE MINIMUM REQUIREMENTS DESCRIBED IN THE
75%
"AMERICAN STANDARDS FOR NURSERY STOCK"
EXISTING TREE
Ptdls
TO REMAIN (1)
2. REMOVE ALL EXISTING TREES ONSITE EXCEPT FOR
THOSE INDICATED ON THE LANDSCAPE PLANS TO REMAIN
- PA QU- 4
(CITY. 5) OR TO BE RELOCATED (CITY. 3). TREES TO BE
MINIMUM LANDSCAPING
RELOCATED OR TO REMAIN SHALL BE PROTECTED
RELOCATED
DURING CONSTRUCTION w/ CITY -APPROVED
TREES (2)
SPECIFICATIONS.
-RU DA -4
3. TREE STUMPS SHALL BE COMPLETELY REMOVED AND
7
DISPOSED OFF THE PROJECT SITE. ALL OTHER TREE
- AR CO -4
STUMPS WITHIN THE PROJECT SHALL BE GROUND 3 FEET
1.5
BELOW FINISHED GRADE.
MA YD
4, PER CITY OF WHEAT RIDGE MUNICIPAL CODE, SECTION
MALLS X YELLOW DELICIOUS'
26-502: ALL NEW LANDSCAPED AREAS SHALL BE SERVED
MAIL KIOSK
BY A FUNCTIONING AUTOMATIC IRRIGATION SYSTEM
12
WHICH COMBINES DRIP AND SUBSURFACE IRRIGATION
_
WITH HIGH EFFICIENCY SPRINKLERS. ALL NEW
MONTMORENCY CHERRY(SEMI-DWARF)7'CAL
IRRIGATION SYSTEMS SHALL BE DESIGNED TO BE ZONES
(3) EXISTING TREES ACCORDING TO WATER NEEDS OF PROPOSED PLANT
TO BE RELOCATED
MATERIALS. ALL NEW IRRIGATION SYSTEMS SHALL BE
0.67
EQUIPPED WITH AUTOMATIC RAIN SHUT-OFF DEVICES.
- PY CA -1
#15
00000`00
Slenaer M.algrese
N_
'
®
�,�•
,
� OOOOr�O
CIVIL)
i
1
0."
Offine,oanebnda
ft muse>be
Cenede
Ka•
Neth
to
7.2
8.67
7.55
CH -5
AT- 4
VI- 5
VI- 4
-ARC0.2
BE TH- 7
PE AT- 3
- Rate Is W di® seaMp. doWe 9 loW Land"
LANDSCAPE NOTES
PROVIDED
1. ALL PLANT MATERIALS SHALL BE TRUE TO TYPE, SIZE,
Srtclgnom -
SPECIES, QUALITY, AND FREE OF INJURY, BROKEN ROOT
05
BALLS, PESTS, AND DISEASES, AS WELL AS CONFORM TO
P
THE MINIMUM REQUIREMENTS DESCRIBED IN THE
75%
"AMERICAN STANDARDS FOR NURSERY STOCK"
EXISTING TREE
Ptdls
TO REMAIN (1)
2. REMOVE ALL EXISTING TREES ONSITE EXCEPT FOR
THOSE INDICATED ON THE LANDSCAPE PLANS TO REMAIN
- PA QU- 4
(CITY. 5) OR TO BE RELOCATED (CITY. 3). TREES TO BE
MINIMUM LANDSCAPING
RELOCATED OR TO REMAIN SHALL BE PROTECTED
RELOCATED
DURING CONSTRUCTION w/ CITY -APPROVED
TREES (2)
SPECIFICATIONS.
-RU DA -4
3. TREE STUMPS SHALL BE COMPLETELY REMOVED AND
7
DISPOSED OFF THE PROJECT SITE. ALL OTHER TREE
- AR CO -4
STUMPS WITHIN THE PROJECT SHALL BE GROUND 3 FEET
1.5
BELOW FINISHED GRADE.
MA YD
4, PER CITY OF WHEAT RIDGE MUNICIPAL CODE, SECTION
MALLS X YELLOW DELICIOUS'
26-502: ALL NEW LANDSCAPED AREAS SHALL BE SERVED
MAIL KIOSK
BY A FUNCTIONING AUTOMATIC IRRIGATION SYSTEM
12
WHICH COMBINES DRIP AND SUBSURFACE IRRIGATION
_
WITH HIGH EFFICIENCY SPRINKLERS. ALL NEW
MONTMORENCY CHERRY(SEMI-DWARF)7'CAL
IRRIGATION SYSTEMS SHALL BE DESIGNED TO BE ZONES
(3) EXISTING TREES ACCORDING TO WATER NEEDS OF PROPOSED PLANT
TO BE RELOCATED
MATERIALS. ALL NEW IRRIGATION SYSTEMS SHALL BE
0.67
EQUIPPED WITH AUTOMATIC RAIN SHUT-OFF DEVICES.
- PY CA -1
#15
NATIVE SEED MIX.
Slenaer M.algrese
- Rate Is W di® seaMp. doWe 9 loW Land"
REQUIRED
PROVIDED
Pelinm Nganon
Srtclgnom -
Te9tlextt
05
3.74
P
CA- 1
75%
Pes pl7ama
Weatem WTmm2u
Ptdls
7
44.03
35%
LOW
MINIMUM LANDSCAPING
3d4sbw Oedba
W. Gratna
Lampton
1
629
—
MA RD
7
BaUarule-ribentlWe
54eoate Orme
HecMe
1.5
9.43
MA YD
4
MALLS X YELLOW DELICIOUS'
sarglm mt—
Yd -Ina - m—
Hdt
12
7.55
_
PRUNUS CERASUS*MONTMORENCY'
MONTMORENCY CHERRY(SEMI-DWARF)7'CAL
NmMbnebsehe
J."_
Nettie
01
0.67
PA
RKING
#15
By,— Fm4w uW
Slenaer M.algrese
N_
2
258
(R
CIVIL)
(
0."
Offine,oanebnda
ft muse>be
Cenede
Ka•
Neth
to
7.2
8.67
7.55
- Rate Is W di® seaMp. doWe 9 loW Land"
046
MU -5 `CAAC-5�TREE(1)�D W. 44TH AVENUE
PLANT SCHEDULE
CITY OF WHEAT RIDGE
SECTION 26-1110 OPEN SPACE REQUIREMENTS
N
MIXED-USE ZONE DISTRICT- MU-
PROPERTYAREA: 62708.1332 S.F.
REQUIRED
PROVIDED
LIGHT, TYR
AR CO- 5I
(RE: LIGHTING)
P& AT- 3
PY CA -1
�PY CA -i
RO WH- 1
CA AC- 10
75%
RO KO -5
E.V. CHARGING STATION
(RE. OWNER) 7
( �RO FIA -t
046
MU -5 `CAAC-5�TREE(1)�D W. 44TH AVENUE
PLANT SCHEDULE
CITY OF WHEAT RIDGE
SECTION 26-1110 OPEN SPACE REQUIREMENTS
N
MIXED-USE ZONE DISTRICT- MU-
PROPERTYAREA: 62708.1332 S.F.
REQUIRED
PROVIDED
I COMMON NAME
15%
30%
OPEN SPACE/LANDSCAPING
9,406 S.F.
19,400 S.F
75%
CR CR
USABLE"
7,055 S.F.
11,500S.F
7' CAL
35%
LOW
MINIMUM LANDSCAPING
3,292 S.F.
13,300S.F.
FIARDSCAPE
7'CAL
10'
' OPEN SPACE: An outdoor, unenclosed area designed and accessible for
Outdoor recreation, pedestrian access, or passive leisure use. May be landscaped
or hardecaped. Does not include roads, parking areas, driveways, or other areas
Intended for vehicular travel.
USABLE OPEN SPACE. Open space which, by its configuration, size, and
design, can be used for passive or active recreation. Usable open space indudes
plazas, parks, outdoor dining areas, courtyards, and green roofs. Required bull re
and parking lot landscaping shall not quality as usable open space. Land with a
slope steeper than one (1) foot (vertical) in three (3) feet (horizontal) shall not
qualify as usable open space.
OPEN SPACE/LANDSCAPING'
KEY
CITY
BOTANICALNAME
I COMMON NAME
I IZE SPACING WATER
DECIDUOUS TREES
J
J
CR CR
1
CRATAEGUS CRUS-GAU VAR. INTERMIS
COCKSPUR THORNLESS HAWTHORN
7' CAL
17
LOW
MA RJ
9
MALUS'RED JEWEL'
RED JEWEL CRABAPPLE
7'CAL
10'
MED
MA RD
7
MALUS X'RED DEUCIOUS'
RED DELICIOUS APPLE (SEMI -DWARF)
2" CAL
17
MED
MA YD
4
MALLS X YELLOW DELICIOUS'
YELLOW DELICIOUS APPLE (SEMI -DWARF)
7' CAL
17
MED
PR CE
6
PRUNUS CERASUS*MONTMORENCY'
MONTMORENCY CHERRY(SEMI-DWARF)7'CAL
10'
MED
PR MR
1
PRUNUS'MOUN7 ROYAL'
MOUNT ROYAL PLUM
#15
10'
MED
PY CA
4
PYRUS CALLERYANA'CHANTICLEER'
CHANTICLEER PEAR
7' CAL
15'
MED
PY LU
1
PYRUS X'LUSCIOUS'
LUSCIOUS PEAR
7' CAL
20'
MED
PY SU
1
PYRUS X'SUMMERCRISP'
SUMMERCRISP PEAR
7' CAL
15'
MED
QU CS
6
QUERCUS'CRIMSON SPIRE'
CRIMSON SPIRE OAK
2" CAL
15'
MED
ULAC
1
ULMUS ACCOLADE
ACCOLADE ELM
2.S'CAL
40' I
MED
EVERGREEN TREES
JU CH
10
JUNIPERUS CHINENSIS'SPARTAN'
SPARTAN JUNIPER
#7
5'
LOW
DECIDUOUS 8 EVERGREEN SHRUBS
AR CO
44
ARCTOSTAPHYLOS X COLORADOENSIS'PANCHITO'
PANCHITO MANZANITA
#3
3.5'
LOW
BETH
32
BERBERIS THUNBERGII'CRIMSON PYGMY'
CRIMSON PYGMY BARBERRY
#5
2'
LOW
CH MI
16
CHAMAEBATIARIA MILLEFOLIUM
FERNBUSH
#5
5'
LOW
DABU
8
DAPHNE X BURKWOODI'CAROL MACKIE
CAROL MACKIE DAPHNE
#5
4'
MED
PEAT
28
PEROVSKIA ATRIPLICIFOLIA
RUSSIAN SAGE
#5
4'
LOW
PH OP
8
PHYSOCARPUS OPULIFOLIUS'DART'S GOLD'
DARTS GOLD NINEBARK
#5
5'
LOW
PI MU
8
PINUS MUGO SIG TUNA'
BIG TUNA MUGO PINE
#5
6'
LOW
PR BE
4
PRUNUS BESSEYI
WESTERN SAND CHERRY
#5
5'
LOW
RO WB
9
ROSA CLIMBING WILLIAM BAFFIN
WILLIAM BAFFIN CLIMBING ROSE
#5
5'
LOW
RO FIA
4
ROSE'HANSA'
HANSA ROSE
#5
6'
LOW
RO KO
18
ROSAXNOCK OUT DOUBLE'
DOUBLE KNOCK OUT ROSE
#5
3'
MED
RO RE
5
ROSA MEIDILAND RED
RED MEMILAND ROSE
#5
6'
LOW
RO WM
7
ROSA MEIDILAND WHITE
WHITE MEIDILAND ROSE
#5
6'
LOW
RU DA
11
RUBUS'DARROW
DARROW BLACKBERRY
#1
5'
MED
SP NI
6
SPIREA NIPPONICA'SNOWMOUND'
SNOWMOUNDSPIREA
#5
5'
MED
PERENNIALS, GRASSES, 8 GROUNDCOVERS
CA AC
42
CALAMAGROSTIS ACUTIFLORA'KARL FOERSTER'
FEATHER REED GRASS
#1
2.5'
LOW
LO RE
3
LONICERA RETICULATA'WNTZLEY'S GHOST
KINTZLEY'S GHOST HONEYSUCKLE
#1
1'
MED
MA RE
89
MAHONIA REPENS
COLORADO CREEPING HOLLY
#1
1.5'
LOW
PA VI
34
PANICUM VIRGATUM'NORTHWIND'
NORTHWIND SWITCHGRASS
#1
2.5'
LOW
PA QU
28
PARTHENOCISSUS QUINQUEFOLIA
VIRGINIA CREEPER
#1
1'
LOW
FOR BURIED UTILITY
INFORMATION
THREE (3) BUSINESS DAYS
a BEFORE YOU DIG CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION CENTER
Know wharlsbelm OF COLORADO (UNCC)
Call betimli yo11 d1¢ VVVVV.UNCC.ORG
z
LU
LU
0
0
Z
U U)
o >
LU w
U) K
Z
IL
W W
x K
m m Q
< :z m
0}o mW
Z Y
U U
W =
U U
7 �
co E
i cDrn 3
10va� ri U'
m m 2 y
o � Lq o <
.0 L
N m
30 5 to
NY O 2SZ N
o
03 d 5
t O �
c_
SUBMITTAL
PREPARED UNOER THE SECTION: 21
SUPERVISONOF: TOWNSHIP: 3S
RANGE. 69W
PROJECT NO: 1527
SHEET
2 OF9
LANDSCAPE PLAN
FRUITDALE LOFTS
U
J
J
NL
r~
LL.
p
LIJ
J
<
Q
H'
LL
LU
W
Z
z
}
LU
S
0
0
O
U
LL
(�
0
~
LU
Q
PREPARED UNOER THE SECTION: 21
SUPERVISONOF: TOWNSHIP: 3S
RANGE. 69W
PROJECT NO: 1527
SHEET
2 OF9
LANDSCAPE PLAN
FRUITDALE LOFTS
DECIDUOUS TREES
COCKSPUR THORNLESS HAWTHORN
MALUS 'RED JEWEL'
RED JEWEL CRABAPPLE
RED DELICIOUS APPLE (SEMI -DWARF)
MALUS X'YELLOW DELICIOUS'
YELLOW DELICIOUS APPLE (SEMI -DWARF)
PRUNUS CERASUS 'MONTMORENCY'
MONTMORENCY CHERRY(SEMI-DWARF)
FRUITDALE LOFTS
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
MOUNT ROYAL PLUM
PYRUS CALLERYANA'CHANTICLEER'
CHANTICLEER PEAR
LUSCIOUS PEAR
PYRUSX'SUMMERCR/SP'
SUMMERCRISP PEAR
QUERCUS 'CRIMSON SPIRE'
CRIMSON SPIRE OAK
ULMUS ACCOLADE
ACCOLADE ELM
EVERGREEN TREES
SPARTAN JUNIPER
NOTES:
1. PRODUCT SHALL BE DERO BIKE BIKE RACK
w/ IN -GROUND MOUNT EMBEDDED INTO CONIC.
BASE. FINISH TO BE THERMOPLASTIC FINISH,
COLOR RED.
5'-7"
w
PLAN VIEW
9
ELEVATION 1, 3-4- Alt
BIKE RACK
NTS
ISOMETRIC
(h
SIDE VIEW
U)
w
0
0
U
Z
U 0
o >
w w
w Ir
U)
z
a
U >
LU w
Ir of
V
Q
J
J
O
H
LL. w
p M O
Jp
LV W U
J Z LLi
Q } �
W
Lu
L
LL P -
0
Q
2
PREPARED UNDER lE SECTION: 21
FOR BURIED UTILITY SUPERVISON OF TONRANGHIIP. S
INFORMATION PROJECT N0: 1527
THREE (3) BUSINESS DAYS
BEFORE YOU DIG CALL 811
(OR 1-800-922-1987) SHEET
UTILITY NOTIFICATION CENTER 3 OF 9
Known when below OF COLORADO(UNCC) SUPPLEMENTAL
call beforeyoudig. WWW.UNCC.ORG LANDSCAPE IMAGES
FRUITDALE LOFTS
FRUITDALE LOFTS
T
a1
FRUITDALE LOFTS
w
z
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
o
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
Z
10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
0
0
w
>
w
Of
Z
°L
DECIDUOUS & EVERGREEN SHRUBS
PERENNIALS I ORNAMENTAL GRASSES
—
w
w
x
W
Ali
In
1
rw'
,
r
r
m
m
W
z
Sed, :.r
U
ARCTOSTAPHYLOS XCOLORADOENSIS 'PANCHITO'
PHYSOCARPUS OPULIFOLIUS 'DART'S GOLD
ROSA MEIDILAND RED
CALAMAGROSTIS ACUTIFLORA 'KARL FOERSTER'
PARTHENOCISSUS QUINQUEFOLIA
PANCHITO MANZANITA
DART'S GOLD NINEBARK
RED MEIDILAND ROSE
FEATHER REED GRASS
VIRGINIA CREEPER
v c
20 E
w v e m d 7
a
�°
0 0 o Q
1
t
L H
Nap McO4i 0
1
I BERBERIS THUNBERGII 'CRIMSON PYGMY'
PRUNUS BESSEYI
ROSA MEIDILAND WHITE
MAHONIA REPENS
CRIMSON PYGMY BARBERRY
WESTERN SAND CHERRY
WHITE MEIDILAND ROSE
COLORADO CREEPING HOLLY
SUBMITTAL
t
CHAMAEBATIARIA MILLEFOLIUM
ROSA CLIMBING 'WILLIAM BAFFIN'
RUBUS'DARROW LONICERA
RETICULA TA'KINTZLEY'S GHOST
FERNBUSH
WILLIAM BAFFIN CLIMBING ROOSSEf��
DARROW BLACKBERRY
KINTZLEY'S GHOST HONEYSUCKLE
Z
LL w
`D-
lips
O
W
r w
;
J C9DAPHNE
Z
BURKWOODCCAROL MACKIE'
ROSE'HANSA'
SPIREA NIPPONICA 'SNOWMOUND'
PANICUM VIRGATUM 'NORTHWIND'
CAROL MACKIE DAPHNE
HANSA ROSE
SNOWMOUND SPIREA
NORTHVNND SWITCHGRASS
Q } Q
J
W
W
,:
Q
3
ILL
—
e
PREPIREO UNOER THE
SECTION'.
FOR BURIED UTILITY
SUPERMSON OF:
.
RANGE 68WS
INFORMATION
i
-
� THREE (3) BUSINESS DAYS
PROJECT NO: 1527
PEROVSKIAATRIPLICIFOLIA
ROSA'KNOCK OUT DOUBLE'
BEFORE YOU DIG CALL 811
RUSSIAN SAGE
DOUBLE KNOCK OUT ROSE
(OR 1-800-922-1987)
SHEET
UTILITY NOTIFICATION CENTER
40179
-
Knowpw,�hatg beim OF COLORADO(UNCC)
SUPPLEMENTAL
YaIlbelomyoUdig. VWAV.UNCC.ORG
LANDSCAPE IMAGES
FRUITDALE LOFTS
PAINT FA
EXISTING
PAINTED
EXISTING
FRUITDALE LOFTS
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
=0803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
O
� F
NINE
! ■�! rq•�
FROSTED GLASS 4 CD
BEDR 0 OM CEILING
GLASS
EV
I j
1
'�'-mow_ �>•
� i I
West - RI
/8" = 1'{
EXISTING RED BRICK
PAINTED WOOD WINDOW FRAME - BROWN
ROOF c
30'- 9" V
— — MEZZANINE
23'-4-4"
NEW ALUMINUM WINDOW FRAMES TO MATCH DUSTING STEEL
PAINT FACIA - BEIGE
_LEVEL 2 n
14'- 71/2" V
EXISTING BLOND BRICK
---�iv 1AITINGSTEEIWINDIDW FRAME
-.- LEVEL
LEV 0
0'-0"
3 East - UNIT 100 - REHABILITATION
z
Lu
0
0
U
O
U n
O �
Luw
O x
z
0
a
K
o
N
N G
O
m N
m
ED m O o
0 U W
Fn
LU
ILE U)
O 0 U N
>
E..
o °
o o Ul G
niozA)` m
u2 r
N Y O N
PAINTED WOOD WINDOW FRAME - BROWN
— — ADDRESS MIN 4"LETTERING
y fT2U174-06e LOST§
SUBMITTAL
0803 WEeST 4411 ji
(V
\ 7 SIGN DETAIL
(V
ADDRESS
— 10803 MIN 4" LETTERING
8 SIGN DETAIL - UNIT 100 _
Q
1/T=Ia
N
Z
LL
Q
O
o
a
0
?OWN J
LV O U
J = of
O
FRAME \ N \ � � ❑
^ J 2
-BEIGE
uJ
LEVEL a `- EV L 0 —LEVEL 0 F_ _
25' - 10" 42 - 6 1 /2" 26' - 0" LL
4 Noithl,- UNIT 100 - REHABILITATION 5 WBest; APT 100 - REHABILITATION 6 South -UNIT 100 - REHABILITATION
V-9,
PREPARED UNDER THE SECTION: 21
FOR BURIED UTILITY SUPERVI—NOR TOWNS
RANGE: lews
INFORMATION PROJECT N0: 1527
THREE (3) BUSINESS DAYS
BEFORE YOU DIG CALL 811
(OR 1-800-922-1987) SHEET
UTILITY NOTIFICATION CENTER 5 OF 9
Know what's belOw. OF COLORADO (UNCC) BUILDING
CaIlbefore you dig. WWW.UNCC.ORG ELEVATIONS
rKUI I DALE LUr
/7♦ ROOF
3p• -- 9"
MEZZA
Ie23. - q.�NINE
— — —
PAINT FACIA - BEIGE
�LEVEL2
v 14'- 7 1/2" ..
EXISTING BLOND BRICK
EXISTING STEEL WINDOW FRAM -
LEVEL 1--
•J 2.-3" ;..
L EL 0
East - Rehabilitation
va-= ra
FRUITDALE LOFTS
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
)W FRAME -BROWN
FRAME- BROWN
V FRAME
FRAME - BROWN
1/8"=I-0
I
j]_ffMj_-1EUL0W
•.. ..
1
3 SDP S;uth - Trash Enclosure 4 SDP East - Trash Enclosure
5 SDP North - Trash Enclosure
1/a-=1.9
MA.
"
6 SDP I -a' -Trash Enclosure
V FRAME
z
w
0
0
U
U o0
o j..
LU
z
0
U)
rn
N
N p
0
m N
} m
ra 0}0 LU o
Z W
U LEI
N W =1
W = N
U rn
0
li m o 0 0
m
x m? m o
m o v o no
0 0 n
ci <n a
DOO , m H
3 0�o t 'D
3 m o
N N p N
m J,
•
SUBMITTAL
PREPARED UNDER TUE SECTION: 21
FOR BURIED UTILITY SUPERVISION OF. TOWNS IP 3S
INFORMATION RANGE. 89W
THREE (3) BUSINESS DAYS PROJECT NO: 1527
BEFORE YOU DIG CALL 811
(OR 1-800-922-1987) SHEET
UTILITY NOTIFICATION CENTER 6 OF 9
�(ppyy yybg bg�QW OF COLORADO(UNCC) BUILDING
Call before you dig. WWW.UNCC.ORG ELEVATIONS
r MUI I UNLC LUr
FRUITDALE LOFTS
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
MATCHLINE - SEE THIS SHEET (RIGHT)
FRUITDALE LOFTS
(15 APARTMENTS) EX FEE: w
5389.37' 1n .,•
2" DOMESTIC SERVICE (WITH 1.5" TAP)
PL 5386.22
90° BEND TC=5386.9E
TC=5386.93 538
LOCALIZED DEPRESSION 4" FIRE SERVICE FL=5386.43 FL= 6.48
SW 5386.49 EX FFE: EX FFE
53872' //r5387.28 EX FFE
I T 7 r4_ EOVERF OW, 5387.19'I� �$
SANITARY SERVICE -
CLEANOUT
6" SANITARY SERVICE
EX FEE:
SW 5386.51 5387.30 -'Hill
m
APPROXIMATE LOCATION OF '\
ELECTRICAL SERVICE AND ,S 5387
TELECOMMUNICATION LINE
(RE: ELECTRICAL ENGINEER)
SW 5386.35 SW 5386.82
LOCALIZED DEPRESSION '..4 ..
EXCLUSIVEUSEAREA
APPROX. 1,837 SF
1 - 7.75%
- ___...... , 5386.241
EX FFE:
5388 30'
I
L.P. 5386.35 {
Al
1p'�b $ 5386.37 �1 {
`TC=5387.12 ''
FL=5386.62 TC=5308.94
FL=5386.44
0.75% FII TC=5387.12
\ 1' FL=5386.62
I=
EMERGENCY OVERFLOW O� til
SIDEWALK CHASEkil
CONCRETE CHANNEL
SIDE(TYP) I-TC=538667 ,FL=538617TC6.87 5.22'.,FL=5386.37
�b TC=5386.64
W 180% ) FL=5386.14
3/4'DOMESTIC SERVICE as 6.77%e
EX FFE: ¢
STEPS - T0=5386.73
STEPS F1= 86.23
4' SANITARY SERVICE 1.80%
_ TC=5387.23
--
FL --5306.73
APPROXIMATE APPROXIMATE LOCATION OF FL -538669
/ FL=5388.48
=45° BEND
0.75% 0.751,
I
5388.05
7C=5386.82 45' BEND
FL=5386.32
5386.11
FL=5386.53
-PL
4 5386.33
PL 5385.84
- - TC=5386.82
A
v
POTENTIAL FUTURE EXPANSION AREA
EXISTING AREA DRAIN
TC=5386.78 I
(TO BE USED FOR SOLAR PANELS WITH INITIAL DESIGN
-. - RIM5385.42
PL 5386.48
\ :
PL 5385.62
BOTTOM OF DRAIN. 5383 92 TIE INTO EXISTING STORM PIPE
PL 5388.18 INV IN: 5584.02
- --- --- - -"'
2.00
(CONTRACTOR TO VERIFY TIE IN
- - INVERTS AND LOCATION)
I
F03
6
ill PROPOSED 6" PVC STORM
SW 5386.98
9W5387.01
III SEWER PIPE Q1.00%
FL=3855385.99
�- L.P.5385.53
m
m
_ I�
' 11"
M STEPS SW 5386.24
' I� 3W 5386.23
PROPOSED 6" AREA DRAIN i
FIFE: 5387.28'
53 j
RIM: OUT.
OUT: 5384.34 � I
STEPS
N.
(LOW POINT TO BE RELEASED TO
-
EX FFE:
ADJACENT STORM NETWORK
EX FFE: 5388.28'
THROUGH GRAVITY FLOW)
5386.80' LOW POINT TO BE�
PUMPED AND
I)
APPROXIMATE DOWNSPOUT RELEASED BY A
!
LOCATION TO DRAIN HISTORICALLY DAYLIGHT PIPE ON THE
TO PROPERTY LINE SURFACE
k \ /
FRUITDALE LOFTS
(15 APARTMENTS) EX FEE: w
5389.37' 1n .,•
2" DOMESTIC SERVICE (WITH 1.5" TAP)
PL 5386.22
90° BEND TC=5386.9E
TC=5386.93 538
LOCALIZED DEPRESSION 4" FIRE SERVICE FL=5386.43 FL= 6.48
SW 5386.49 EX FFE: EX FFE
53872' //r5387.28 EX FFE
I T 7 r4_ EOVERF OW, 5387.19'I� �$
SANITARY SERVICE -
CLEANOUT
6" SANITARY SERVICE
EX FEE:
SW 5386.51 5387.30 -'Hill
m
APPROXIMATE LOCATION OF '\
ELECTRICAL SERVICE AND ,S 5387
TELECOMMUNICATION LINE
(RE: ELECTRICAL ENGINEER)
SW 5386.35 SW 5386.82
LOCALIZED DEPRESSION '..4 ..
EXCLUSIVEUSEAREA
APPROX. 1,837 SF
1 - 7.75%
- ___...... , 5386.241
EX FFE:
5388 30'
I
L.P. 5386.35 {
Al
1p'�b $ 5386.37 �1 {
`TC=5387.12 ''
FL=5386.62 TC=5308.94
FL=5386.44
0.75% FII TC=5387.12
\ 1' FL=5386.62
I=
EMERGENCY OVERFLOW O� til
SIDEWALK CHASEkil
CONCRETE CHANNEL
SIDE(TYP) I-TC=538667 ,FL=538617TC6.87 5.22'.,FL=5386.37
�b TC=5386.64
W 180% ) FL=5386.14
3/4'DOMESTIC SERVICE as 6.77%e
EX FFE: ¢
STEPS - T0=5386.73
STEPS F1= 86.23
4' SANITARY SERVICE 1.80%
_ TC=5387.23
--
FL --5306.73
APPROXIMATE APPROXIMATE LOCATION OF FL -538669
/ FL=5388.48
=45° BEND
0.75% 0.751,
I
5388.05
7C=5386.82 45' BEND
FL=5386.32
5386.11
FL=5386.53
-PL
4 5386.33
SpG n
-dia
� 1\
PROPERTY LINE
NORMA
5386 ANDERSON
PROPOSED PRESCHOOL GRADE BREAK _..•5388.10�R
I _ f ESCHOOL
5386.2555
j
53�
1.45%
MRwgam-mMM a m m mmimiiiiii
MATCHLINE - SEE THIS SHEET (LEFT)
IRRIGATION TAP NOTE
1. IRRIGATION TAP TO OCCUR ON THE DOMESTIC
WATER SERVICE AFTER THE BACKFLOW PREVENTER
I WITHIN THE BUILDING. IRRIGATION CONSULTANT TO
ELECTRICAL TRANSFORMER
TC=5387.33 I PL 5385. T4 CONFIRM THAT THIS IS ALLOWABLE WITH THE
(RE: ELECTRICAL ENGINEER) -W-- 1.40% UPSIZE DOMESTIC SERVICE LINE FROM
FL=5386.83 DENVER WATER DEPARTMENT.
0310 ° METER IN MANHOLE 1.5" TO 2" AT A LOCATION 5' PAST THE
1 o c i TC=5387.33 y OUTSIDE OF THE WATER METER MANHOLE
TC=5387.24 I FL=5386.83 �n 495°I° TC=5386.18
FL=5386.14 / ,y. /�
PL 5387.36
_.=-METERIN TC 5388.38-r �... PL 538580
N MANHOLE -__ : TC=5387.34.- FL=6386.66 FL 5385.88 _ FVA
71E INTO EXISTING FLOWLINE _ -- EXISTING FIRE HYDRANT
S'
- 7 FL=5386.84 -- -�
APPROXIM (TE LOCATION OF EXISTING ) FL -5386.86 ( c -. e ELSECURB STOP ELECTRIC CAR CHARGING150.00' FROM PROPERTY LINE TO LE TC=538736 F-
10 00 STATIONS ONE TO BE -
J\�FIREHYDRANT ON NORTH SIDE OF 44TH AVE INSTALLED INITIALLY, AND THE CURB STOP 1000' EXISTING`NATER MAIN - E
CORP STOP - OTHER TO BE INSTALLED IN
THE FUTURE) CORP STOP-
- -44TH AVE
W. ° - - - -
TAPPING SLEEVE
,. f f -L- W/TAPPING VALVE -_ .�;,.,
I 166' EXITING R.O.'+V.I 7
t EXISTING ELECTRIC
z' I �. EXISTING SANITARY SEWER :
\� APPROXIMATE LOCATION OF EXISTING FIRE HYDRANT APPROXIMATE LOCATION OF EXISTING FIRE HYDRANT
20 0 20 40
SCALE 1'=20' FEET
FOR BURIED UTILITY
INFORMATION
THREE (3) BUSINESS DAYS
BEFORE YOU DIG CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION CENTER
Know wham below OF COLORADO (UNCC)
Callbdmeyou ck WWW.UNCC.ORG
zI0
w '
SUBMITTAL
U
J
J
NcoO
LL ? of
p o
J p
W UJ U
J Z (D
Q J
H W �
I--'
LL ~
Q
PREPARED UNDER TBE SECTION: 21
SUP-GON OF: I TOWNSHIP: 3S
RANGE: SOW
PROJECT NO: 1527
SHEET
9OF8
UTILITY &
GRADING PLAN
FRUITDALE LOFTS
PL 5385.84
- - TC=5386.82
FL=5386.32
PL 5385.73
_�
075
-0
TC=5386.78 I
FL=53868
O 9` I
i
-CONCRETE CHANNEL ---
TC=5386.53
F03
PL 5385.44
TC=5386.49
FL=3855385.99
85.58PLL=5386
5.52
SpG n
-dia
� 1\
PROPERTY LINE
NORMA
5386 ANDERSON
PROPOSED PRESCHOOL GRADE BREAK _..•5388.10�R
I _ f ESCHOOL
5386.2555
j
53�
1.45%
MRwgam-mMM a m m mmimiiiiii
MATCHLINE - SEE THIS SHEET (LEFT)
IRRIGATION TAP NOTE
1. IRRIGATION TAP TO OCCUR ON THE DOMESTIC
WATER SERVICE AFTER THE BACKFLOW PREVENTER
I WITHIN THE BUILDING. IRRIGATION CONSULTANT TO
ELECTRICAL TRANSFORMER
TC=5387.33 I PL 5385. T4 CONFIRM THAT THIS IS ALLOWABLE WITH THE
(RE: ELECTRICAL ENGINEER) -W-- 1.40% UPSIZE DOMESTIC SERVICE LINE FROM
FL=5386.83 DENVER WATER DEPARTMENT.
0310 ° METER IN MANHOLE 1.5" TO 2" AT A LOCATION 5' PAST THE
1 o c i TC=5387.33 y OUTSIDE OF THE WATER METER MANHOLE
TC=5387.24 I FL=5386.83 �n 495°I° TC=5386.18
FL=5386.14 / ,y. /�
PL 5387.36
_.=-METERIN TC 5388.38-r �... PL 538580
N MANHOLE -__ : TC=5387.34.- FL=6386.66 FL 5385.88 _ FVA
71E INTO EXISTING FLOWLINE _ -- EXISTING FIRE HYDRANT
S'
- 7 FL=5386.84 -- -�
APPROXIM (TE LOCATION OF EXISTING ) FL -5386.86 ( c -. e ELSECURB STOP ELECTRIC CAR CHARGING150.00' FROM PROPERTY LINE TO LE TC=538736 F-
10 00 STATIONS ONE TO BE -
J\�FIREHYDRANT ON NORTH SIDE OF 44TH AVE INSTALLED INITIALLY, AND THE CURB STOP 1000' EXISTING`NATER MAIN - E
CORP STOP - OTHER TO BE INSTALLED IN
THE FUTURE) CORP STOP-
- -44TH AVE
W. ° - - - -
TAPPING SLEEVE
,. f f -L- W/TAPPING VALVE -_ .�;,.,
I 166' EXITING R.O.'+V.I 7
t EXISTING ELECTRIC
z' I �. EXISTING SANITARY SEWER :
\� APPROXIMATE LOCATION OF EXISTING FIRE HYDRANT APPROXIMATE LOCATION OF EXISTING FIRE HYDRANT
20 0 20 40
SCALE 1'=20' FEET
FOR BURIED UTILITY
INFORMATION
THREE (3) BUSINESS DAYS
BEFORE YOU DIG CALL 811
(OR 1-800-922-1987)
UTILITY NOTIFICATION CENTER
Know wham below OF COLORADO (UNCC)
Callbdmeyou ck WWW.UNCC.ORG
zI0
w '
SUBMITTAL
U
J
J
NcoO
LL ? of
p o
J p
W UJ U
J Z (D
Q J
H W �
I--'
LL ~
Q
PREPARED UNDER TBE SECTION: 21
SUP-GON OF: I TOWNSHIP: 3S
RANGE: SOW
PROJECT NO: 1527
SHEET
9OF8
UTILITY &
GRADING PLAN
FRUITDALE LOFTS
E
F
�2�
xn
I Q
xo
FRUITDALE LOFTS
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
NEW CHAIN LINK FENCE/ GATE
INSTALL WITH SHADE TILTED TO THE
MAXIMUM OF 00' TO LIMIT LIGHT SPILL
OVER PROPERTY UNE AND PRODUCE AN
ASYMMETRICAL LIGHT DISTF48UTION TOWARD
THE ENTRANCE
•0.9 0.8 't d ' . .6 'IS 1.1 0.)10.4 02
.0555 '0.80.8 0.8 *1.0 1.7 A 1.1'2.01.0 'OS'0.3
0. '1.10.8 '1 '4.4'3.0
•0 02 'o.2 02 'v o.8 1.0 0. 1 1.3 .1 4.4 ' 3.1 '1A 0.]'0.3
' 3' 1.82.01.0 0.5 0.3 02 0.2 03 0.40.]1.4 3.0'22
4' SIDEWALK Z
•OJ,I 4.4 3.1 .3 .3 1.1 0.5 0.3 02 02 0.3 'OA '0.]'1 '3 '4. 2 4.4'2.5'12 A'0.)'0.8'1.11.6 1.6'1.]'12'0.]0.1'0.3
•0't '4.1'13'3. '2.0'1A'0A 0.3'0.3 01 '0.]'OA '0.] 1.3 A'3. '3. '3A 1.9'1.1.7'DA '0.6'03*0A .9'09'0.]'03'03'0.2
PATIO 1 '32'3.1'2.4'1. '09
0.1 • .1 02 0.3 '0.) 1. '1 '1.1 '1.0 '1.4 22 32 'aS 3.1 'z.1 '1.] 'OA ' 'O.a 0.3 0.3 'O.a ' 0.6 0.8 12 1. 1. 13 1.0 'OA ' . .] '0.] 0.6 0.4 X0.3 0.2
'0.1 0.1 0.1 02 OA 0.60.8 0.8 1.1 11 3.1 I.fi 'IS 43 2.51.3 0.]0.5 03 0.3 03 0.40.6 09 '1A'1. 1. '1S 1.1 OA0.60.60.]091.1121.10.9 0.6'0.1 0.2
I,
•0 � .0.1 '0.1 '03 '0.3 '0.1 '0.6 '0.8 '1.1 '19 Z '4.6 '2.1 '1.3 '0.) '0.4 '0.3 '0.3 0.3 '0.3 'OS '0.7 '1.3 '22 '3. '3. '2.5 '1.5 '09 '0.7 '0.7 '09 '1.d '22 '25 '2.3 '1.5 09 OS '0.3
I,
O.WJ 0.1 '0.1 '02 '02 '0.4 '0.6 '09 '1.4 '1.9 '3.0 4.3 42 '3.B '23 '1.1 '0.6 0.1 03 '0.3 '0.3 '0.3 0.5 '0.9 '1.] '3A '4. '4. O . '0.8 '0.5 '12 '22 '3.8 ' i 0.6 0.3
*02
•01 0.1'0.1'0.1'02'0.4'0.]'12'1.)'2.0'22 2.6 2.6' 21.4'09'0.6'DA 03'0.3'0.3'0./OS0.9 19'3 42 2.2 ' 12'.8 'OA 13 ZB '1.1 '3.0 '1.O 0.6'0.3
,..c '0.1 0.1 '0.1 '0.1 '02 '0.4 '0A '1.6 '2.6 '22 '1A 1.6 1.5 ' .3 '1.0 '02 'OS 'OA 03 '0.3 '0.3 '0.4 '0.5 '0.9 '1.6 '3. '4. '4. '3.3 1.8 '1.0 '0.] '0.8 '12 '22 '3.9 '4.0 '4.1 '2.5 'Ui'O.6 '0.3
•0 1 0.1 0.1 0.1 02 '0.4'OA ZA-02.0'1.6 1.2 12'.1'1.0'09'0.60.1 0.3 03 0.3'OA '0.6'0.8'13'2. '2. '2.2.0'1.3'09'0.6'0.]'09'tA'22'2.8'2.31.5'0X 10.5'0.3
.0 � 0.1 '0.1 '0.1 '02 '0.3 '0.6 Z -A-01.6 '1.3 1.3 1A '1.5 '1A '1.1 0.1 'O.5 'OA '03 *13 'OA '0.6 'O.9 '1A '1 '2. '1. 1.5 '1.0 '0.) 0.6 '0.5 'O.6 'O.8 '1.1 '12 '1.1 '0.6 '0 10.3 '03
•OAI 0.0 '0.1 '0.1 'OS '0.3 '0.1 '0.] '1.0 1.1 . 1.) 2.5 .9 '2.7 '1A '1.1 0.6 'OA '03 'GA '0.5 '0.7 '1.2 '2.0 '2 '3. '2. '1.6 '1.0 '0.7 '0.5 '0.4 '0.5 '0.5 '0.8 '0.6 '0.6 '0.5 '0.1102 '02
0.01.0.0'0.1'0.1*0.1'02'0.3'OA '0.8*OA '112.3 Z8'2.8 '+A 0.8 'Os'OA'0.0 0.5 0.81.8Z 1.2.114'0.]'0.5'0.4'0.4'OA '0A'0.4'0.4'0.3 0.3102 '0.1
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
'0.01 OA 0.0 0.1 0.1 0.1 02 03 0.5 0.) 1.3 2.5 4A .3 4.5 3A 1.6 0.8 0.5 OA OA 0.5 0.9 1.8 3.) 4. 3. 4. 2.4 12 0.7 05 0.4 OA 0A OA 02 0.3 0.3 021 D3 0.1
'OA 0.)1.1 22 3.8 2'4.2'x.8'1.1'0.8 'O. S'OA'OA'0.5'0.8'1.5 '3.0 '4. '4. '3. '2.0'1.1'0.]'05'0.4' O.4 '0.4 'OA':A'0.4'0A'0.3 iC2 '0.2
'O.fi'1.0 1.6 2.4 A'2.fi1A.1.1'0.]'OA '0.3'0.3 '0.40.61.1 '1A'2. '2. 1. 't.fi'1.1'0.]'0.fi'0.5'0.5 '0.6'0.]'0.]'0.]'0.6 'OA� b' 02
'001 1.0 11 1.9 '0..'OA'030.3 'OA' 1. '1 0.]'0.6'0.]'1.0'1.4'131A 1.0
0.60.813 2.0 2.7'28'2.1'1.4'0 '0.5 '0.4 '03'O.a 'OA 1'0.6'0.9121. '2.;-4
'1.9'1.3 09'0.8'1.0'1.]'2.8'311.0'1.9'1. �OS'0.3
.1 4.4451.2 0.90.50.303'0.20.3'0.3 '0.8'1.12. 1 3.2' 1.1'0.91.3'2.4 13 2.8 1.3x0.60.3
APARTMENT 100 3.]19090.503020.2030.3'0.5'0.8 4.02112'1.0'1.3'25 4.3 1.1 x0.6'0.3
.8'0.]'0.9'1]'3.3 Z844'3.5'1.7'0.8'0.5'0.302 0.2 02 0.3 'OA 0.7'i.5'1.0'4AZB 4.0'2212'0.9'1.119'3.3'3.7'35'22 1.1 r0.5 'G.3
.5'0.6 OA1.3'22'32*32'2.3'13'0.79.463'02'6.202030.40.]122.3'3.6'31*3.0'IA '1.1 0.6'0.8'121.]'IS '1.)'1.2 03 rOA'0.2
.3'0.5O.]1.01.41.]'1.7'1.3'ge'0.6OA0.3'02'0.2'02*02'0.4'0.6'1.01.5'2.1'22'1.912 0.9 0.1'0.8'0.]'0.8'0.9'0A'0.6 0A L03'0.2
oZ, 3'OS 0.]1.0'1.31.4'13'1.0'0.]'SS 0.3'02'03'0.2'02030.1'0.6'0.91.1'1.7'1.81 S
.6 ,2 '0.8'cA'OS'O'0.5'OA'0.4'0.3 03102'0.1
•021 '0.1'0 '0.6 Z S'A0.61.01.6.2.12.11A 12'0.]OS'0.3'02'02 0.2'02'030.1 0.6.1.1 ' 1.82A 2A'2.41.5'0.9'0.6'OA'03'0.3'0.3'02'0.2 0210.1'0.1
'0.11 0.1'02'0.4'030.5 0.4 0.5.7'1.4'2.7'3.83A'3. 6'dA 'OS'0.3*02*02*01'0201'0.4'01.4'2.11 1.11.82.11.1.0.6'OA'03'0.2 030.1 0.10.110.1'0.1
'O.tI 0.1 '0.1 '02 '03 '0.3 '03 'OS ' .8 1.8 37.7( j'' 3.7 1.0 '2.0 'OS 0.3 '0.2 '01 0.1 '03 03 ' '0.] '1S 3.3 Z '1.4 '2.6 '1.1 '0.6 '03 '02 '0.2 '0.1 '0.1 0.1 0.1 10.1 '0.0
0.1 '0.1 '1A 11'01' 03 'OA'.6'1.fi 'rfi4.2 '41 '3A' 11 '09 S' 0.3 '0.2'0.1 '0.1 '01 �-0-00
.4'0.6'13'2.]'4. .4.0'3A '2A ' 1.0'0.5 '03 '02 '0.1 '0.1 0.1 0.10.110.0'0.0
I '0.0 '0.1 '0.1 '0.1 '0.1 '02 '0.3 ' . 12 '2A '1.3 '0.] '0. '0.2 '01 '0.1 '0.1 '0.1 .3 '0.5 '09 '1.fi '2. ' . 0.0 0.0 10.0 '0.0
0.0 0.0 0.0 0.1 0.1 '0.1 '01 '0.3 'OA 'O.6 '01pP4p904I153 '02 '0.1 '0.1 '0.1 '0.1 '0.1 ' ' '3' '0S '0.6 '0.5 '0.4 'Od '02 '0.1 '0.1 '0.1 .4'00 '0.0 '0.0 '0A.O
I.Ji a.3 000
WEST 44TH AVENUE
© SITE PHOTOMETRIC PLAN
SCALE: 1" = 20'-0"
Luminaire Schedule
0.2 02
1.a64
DuaMiN
QBnJ6c6r
C -g -r -i-
'02 '0.3 '03 '03 '0.3 'O3 '0.3 '0.4 '0.4 '0.3
'- '
0.4 'Oil O2 0.1
.1O.pkSbR02 0.2
Q#4-2-
02 0.1
U M
'03'020A
'0.6 0.5 0.6 'O.5 'O.5 'O.6
Z8
--71I
r
'4'0'2'2'2'2''OA '0.4 'OA .OA
1.0 1.0090.5 0.2
BEACW
PROCUCfS
SEfL248B SETT Area Wnireira5000(
555KNNV/lOPD ve1M1 ln6�ec+D1aV34tm
1.1 '0.7 '0.4 '0.3 'OS '02 '0.3 '0.3 '0.5 '0.] '0.8 '0.8 '0�
'1.3 3.3 1.8 0.9 0.5 'OA '0.3 '03 '0.4 '0.5 '0.8 '1.4 1.8 '1.8 114I
0.5 '03
'0.9 '0.5
SETL24N9
555W
IX D.ES
ZA -A
'0
Z
'1.0'1.]'3
.9 .1 .4 A 1.3
•0i
1.2'191
S 4.5 '0' .J.4
1.8 09
Z
12 • ,1 I
8'39291.8 0.81.01.]3.0'4 4.1 .3}
1.9'0.9
192.8'
•Ot
'o.1
.0
0.j
Z
0.VNRA.iea
58&182]
1. 1 2A
ZA ,. ',1270.5
0.0.5
1.30.]
'OS
'OA
.4'03
OA
ZA
0 'O.i4Q4Q
0 'of
EXISTING CHAIN LINK FENCE moo./
•o,�
MDSlM111 CAST AUIMINUM
MWNTING HEIGHT. 124'AFG
o. 'a.p
I
a.e 'o.e
Z
UZ
tt
SASENIE
CV41-0R-WG491ID
lED(tw0 ALL MWMVAM 4000K
�9 YMOV CA9T PLUMNUM
sING
LID
1
OLV1WM.b
182)
092
t5.a
'3.3 '22
FRUITDALE LOFTS
(15 APARTMENTS)
e
°' 32
4.3 '3.3
0
Z
INSTALL WITH SHADE TILTED TO THE
MAXIMUM OF 00' TO LIMIT LIGHT SPILL
OVER PROPERTY UNE AND PRODUCE AN
ASYMMETRICAL LIGHT DISTF48UTION TOWARD
THE ENTRANCE
•0.9 0.8 't d ' . .6 'IS 1.1 0.)10.4 02
.0555 '0.80.8 0.8 *1.0 1.7 A 1.1'2.01.0 'OS'0.3
0. '1.10.8 '1 '4.4'3.0
•0 02 'o.2 02 'v o.8 1.0 0. 1 1.3 .1 4.4 ' 3.1 '1A 0.]'0.3
' 3' 1.82.01.0 0.5 0.3 02 0.2 03 0.40.]1.4 3.0'22
4' SIDEWALK Z
•OJ,I 4.4 3.1 .3 .3 1.1 0.5 0.3 02 02 0.3 'OA '0.]'1 '3 '4. 2 4.4'2.5'12 A'0.)'0.8'1.11.6 1.6'1.]'12'0.]0.1'0.3
•0't '4.1'13'3. '2.0'1A'0A 0.3'0.3 01 '0.]'OA '0.] 1.3 A'3. '3. '3A 1.9'1.1.7'DA '0.6'03*0A .9'09'0.]'03'03'0.2
PATIO 1 '32'3.1'2.4'1. '09
0.1 • .1 02 0.3 '0.) 1. '1 '1.1 '1.0 '1.4 22 32 'aS 3.1 'z.1 '1.] 'OA ' 'O.a 0.3 0.3 'O.a ' 0.6 0.8 12 1. 1. 13 1.0 'OA ' . .] '0.] 0.6 0.4 X0.3 0.2
'0.1 0.1 0.1 02 OA 0.60.8 0.8 1.1 11 3.1 I.fi 'IS 43 2.51.3 0.]0.5 03 0.3 03 0.40.6 09 '1A'1. 1. '1S 1.1 OA0.60.60.]091.1121.10.9 0.6'0.1 0.2
I,
•0 � .0.1 '0.1 '03 '0.3 '0.1 '0.6 '0.8 '1.1 '19 Z '4.6 '2.1 '1.3 '0.) '0.4 '0.3 '0.3 0.3 '0.3 'OS '0.7 '1.3 '22 '3. '3. '2.5 '1.5 '09 '0.7 '0.7 '09 '1.d '22 '25 '2.3 '1.5 09 OS '0.3
I,
O.WJ 0.1 '0.1 '02 '02 '0.4 '0.6 '09 '1.4 '1.9 '3.0 4.3 42 '3.B '23 '1.1 '0.6 0.1 03 '0.3 '0.3 '0.3 0.5 '0.9 '1.] '3A '4. '4. O . '0.8 '0.5 '12 '22 '3.8 ' i 0.6 0.3
*02
•01 0.1'0.1'0.1'02'0.4'0.]'12'1.)'2.0'22 2.6 2.6' 21.4'09'0.6'DA 03'0.3'0.3'0./OS0.9 19'3 42 2.2 ' 12'.8 'OA 13 ZB '1.1 '3.0 '1.O 0.6'0.3
,..c '0.1 0.1 '0.1 '0.1 '02 '0.4 '0A '1.6 '2.6 '22 '1A 1.6 1.5 ' .3 '1.0 '02 'OS 'OA 03 '0.3 '0.3 '0.4 '0.5 '0.9 '1.6 '3. '4. '4. '3.3 1.8 '1.0 '0.] '0.8 '12 '22 '3.9 '4.0 '4.1 '2.5 'Ui'O.6 '0.3
•0 1 0.1 0.1 0.1 02 '0.4'OA ZA-02.0'1.6 1.2 12'.1'1.0'09'0.60.1 0.3 03 0.3'OA '0.6'0.8'13'2. '2. '2.2.0'1.3'09'0.6'0.]'09'tA'22'2.8'2.31.5'0X 10.5'0.3
.0 � 0.1 '0.1 '0.1 '02 '0.3 '0.6 Z -A-01.6 '1.3 1.3 1A '1.5 '1A '1.1 0.1 'O.5 'OA '03 *13 'OA '0.6 'O.9 '1A '1 '2. '1. 1.5 '1.0 '0.) 0.6 '0.5 'O.6 'O.8 '1.1 '12 '1.1 '0.6 '0 10.3 '03
•OAI 0.0 '0.1 '0.1 'OS '0.3 '0.1 '0.] '1.0 1.1 . 1.) 2.5 .9 '2.7 '1A '1.1 0.6 'OA '03 'GA '0.5 '0.7 '1.2 '2.0 '2 '3. '2. '1.6 '1.0 '0.7 '0.5 '0.4 '0.5 '0.5 '0.8 '0.6 '0.6 '0.5 '0.1102 '02
0.01.0.0'0.1'0.1*0.1'02'0.3'OA '0.8*OA '112.3 Z8'2.8 '+A 0.8 'Os'OA'0.0 0.5 0.81.8Z 1.2.114'0.]'0.5'0.4'0.4'OA '0A'0.4'0.4'0.3 0.3102 '0.1
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
'0.01 OA 0.0 0.1 0.1 0.1 02 03 0.5 0.) 1.3 2.5 4A .3 4.5 3A 1.6 0.8 0.5 OA OA 0.5 0.9 1.8 3.) 4. 3. 4. 2.4 12 0.7 05 0.4 OA 0A OA 02 0.3 0.3 021 D3 0.1
'OA 0.)1.1 22 3.8 2'4.2'x.8'1.1'0.8 'O. S'OA'OA'0.5'0.8'1.5 '3.0 '4. '4. '3. '2.0'1.1'0.]'05'0.4' O.4 '0.4 'OA':A'0.4'0A'0.3 iC2 '0.2
'O.fi'1.0 1.6 2.4 A'2.fi1A.1.1'0.]'OA '0.3'0.3 '0.40.61.1 '1A'2. '2. 1. 't.fi'1.1'0.]'0.fi'0.5'0.5 '0.6'0.]'0.]'0.]'0.6 'OA� b' 02
'001 1.0 11 1.9 '0..'OA'030.3 'OA' 1. '1 0.]'0.6'0.]'1.0'1.4'131A 1.0
0.60.813 2.0 2.7'28'2.1'1.4'0 '0.5 '0.4 '03'O.a 'OA 1'0.6'0.9121. '2.;-4
'1.9'1.3 09'0.8'1.0'1.]'2.8'311.0'1.9'1. �OS'0.3
.1 4.4451.2 0.90.50.303'0.20.3'0.3 '0.8'1.12. 1 3.2' 1.1'0.91.3'2.4 13 2.8 1.3x0.60.3
APARTMENT 100 3.]19090.503020.2030.3'0.5'0.8 4.02112'1.0'1.3'25 4.3 1.1 x0.6'0.3
.8'0.]'0.9'1]'3.3 Z844'3.5'1.7'0.8'0.5'0.302 0.2 02 0.3 'OA 0.7'i.5'1.0'4AZB 4.0'2212'0.9'1.119'3.3'3.7'35'22 1.1 r0.5 'G.3
.5'0.6 OA1.3'22'32*32'2.3'13'0.79.463'02'6.202030.40.]122.3'3.6'31*3.0'IA '1.1 0.6'0.8'121.]'IS '1.)'1.2 03 rOA'0.2
.3'0.5O.]1.01.41.]'1.7'1.3'ge'0.6OA0.3'02'0.2'02*02'0.4'0.6'1.01.5'2.1'22'1.912 0.9 0.1'0.8'0.]'0.8'0.9'0A'0.6 0A L03'0.2
oZ, 3'OS 0.]1.0'1.31.4'13'1.0'0.]'SS 0.3'02'03'0.2'02030.1'0.6'0.91.1'1.7'1.81 S
.6 ,2 '0.8'cA'OS'O'0.5'OA'0.4'0.3 03102'0.1
•021 '0.1'0 '0.6 Z S'A0.61.01.6.2.12.11A 12'0.]OS'0.3'02'02 0.2'02'030.1 0.6.1.1 ' 1.82A 2A'2.41.5'0.9'0.6'OA'03'0.3'0.3'02'0.2 0210.1'0.1
'0.11 0.1'02'0.4'030.5 0.4 0.5.7'1.4'2.7'3.83A'3. 6'dA 'OS'0.3*02*02*01'0201'0.4'01.4'2.11 1.11.82.11.1.0.6'OA'03'0.2 030.1 0.10.110.1'0.1
'O.tI 0.1 '0.1 '02 '03 '0.3 '03 'OS ' .8 1.8 37.7( j'' 3.7 1.0 '2.0 'OS 0.3 '0.2 '01 0.1 '03 03 ' '0.] '1S 3.3 Z '1.4 '2.6 '1.1 '0.6 '03 '02 '0.2 '0.1 '0.1 0.1 0.1 10.1 '0.0
0.1 '0.1 '1A 11'01' 03 'OA'.6'1.fi 'rfi4.2 '41 '3A' 11 '09 S' 0.3 '0.2'0.1 '0.1 '01 �-0-00
.4'0.6'13'2.]'4. .4.0'3A '2A ' 1.0'0.5 '03 '02 '0.1 '0.1 0.1 0.10.110.0'0.0
I '0.0 '0.1 '0.1 '0.1 '0.1 '02 '0.3 ' . 12 '2A '1.3 '0.] '0. '0.2 '01 '0.1 '0.1 '0.1 .3 '0.5 '09 '1.fi '2. ' . 0.0 0.0 10.0 '0.0
0.0 0.0 0.0 0.1 0.1 '0.1 '01 '0.3 'OA 'O.6 '01pP4p904I153 '02 '0.1 '0.1 '0.1 '0.1 '0.1 ' ' '3' '0S '0.6 '0.5 '0.4 'Od '02 '0.1 '0.1 '0.1 .4'00 '0.0 '0.0 '0A.O
I.Ji a.3 000
WEST 44TH AVENUE
© SITE PHOTOMETRIC PLAN
SCALE: 1" = 20'-0"
Luminaire Schedule
Sy-
1.a64
DuaMiN
QBnJ6c6r
C -g -r -i-
laep
=-
Fi-
Lu lane
U M
WaOzga
Z8
t6
BEACW
PROCUCfS
SEfL248B SETT Area Wnireira5000(
555KNNV/lOPD ve1M1 ln6�ec+D1aV34tm
24 SAMSUNG S-
LEDs
1
SETL24N9
555W
IX D.ES
50.593
0.92
Se.t
TOTAL HEIGHT. 124'AFG
6
LNSEtI]E
-2-0R-NG-OBiID
�G120M WALL MOUM Wi1114]001(
IID
t
0.VNRA.iea
58&182]
1.23
20
ZA
MDSlM111 CAST AUIMINUM
MWNTING HEIGHT. 124'AFG
UZ
tt
SASENIE
CV41-0R-WG491ID
lED(tw0 ALL MWMVAM 4000K
�9 YMOV CA9T PLUMNUM
sING
LID
1
OLV1WM.b
182)
092
t5.a
MOUNTMG HEIGHi.94'
TEMPLE BUELL MEMORIAL GARDEN
GENERAL NOTES
I. ANY PROPOSED LUMINAIRES INSTALLED ON PRNATE PROPERTY, ADJACENT TO THE PUBLIC
RIGHT-OF-WAXSHALL BE ORIENTED IN SUCH A MANNER OR UMRED IN LUMEN OUTPUT TO PREVENT
GLARE PROBLEMS AND SHALL NOT EXCEED NATIONAL I.E.S. UGHRNG STANDARDS FOR DISABILITY GLARE.
Z
0
z
w
0
0
u,
W
a
� 0
O
SUBMITTAL
U
J
J
O
N
LL LU
0 o
O
U)U
W lL
J Z 'L'j^
QV
Q J QN/
I- LU LL
Z
LLJ
LL P
Q
SECTION: 21
TOWNSHIP: 3S
RANGE: 6SW
PROJECT NO: 1527
SHEET
SOF8
PHOTOMETRIC
SITE PLAN
M
-12-10 200—
vWc
LI2IEL 1 01200—
vWc
TYPE ZA, UZ
I _y
CHI1Fx/CGIAAx001NC/810 D011FRK0149IIOOINCtEIA
CH _ DB �.. SL
011i - C!I/D"
AA
A
8
B I B
LT7.4
101C�Il l
M 124M87a0 M]
!+aY 1P� �A1�1�24H .T' '
u
x0O�pa
]
110011Iv9940wWN
o.
A5oµiAa?2k�ocGN
I
]rNX!Sn
5....
"12ti00m00000Aw1.4YvV
'C
2P�
® {74M11w1 UON 12 POLE � � Y SEII (LEDI
A c D e F a x
FRUITDALE LOFTS
SITE DEVELOPMENT PLAN
NORTH HALF OF SECTION 21, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN
CITY OF WHEAT RIDGED, COUNTY OF JEFFERSON, STATE OF COLORADO
10803 WEST 44th AVENUE, WHEAT RIDGE, CO 80033
GENERAL NOTES
1. ANY PROPOSED LUMINAIRES INSTALLED ON PRIVATE PROPERTY, ADJACENT TO THE PUBLIC
RIGHT-OF-WAY, SHALL RE ORIENTED IN SUCH A MANNER OR LIMITED IN LUMEN OUTPUT TO PREVENT
GLARE PROBLEMS AND SHALL NOT EXCEED NATIONAL I.E.S. LIGHTING STANDARDS FOR DISABILITY GIME
BCER.
SUBMITTAL
U
J
J
~~
LL W
p 20
J N p
LV W V
J Z
H W
H
Lu
LL F -
Q
SECTION: 21
TOWNSHIP: 3S
RANGE: 69W
PROJECT NO: 1527
SHEET
80F9
LIGHTING DETAIL
PLAN
rKUI I DALE LUH 16
Cily of
W heat 1idgc
COMMUNI TY DEVELOPMLN I
Community Development
7500 West 29th Avenue
Wheat Ridge, Colorado 80033
Ph: 303.235.2846 Fax: 303.235.2857
Community Development Referral Form
Date Mailed: September 20, 2016 Response Due: October 4, 2016
The Wheat Ridge Community Development Department has received a request for approval of a site
plan application for the redevelopment and reuse of Fruitdale School at 10803 W. 44th Avenue—see
vicinity map on page two.
No response from you will constitute having no objections or concerns regarding this proposal.
Case No.: WSP-16-05 / Fruitdale Site Plan
Request: The applicant, Hartman Ely Investments (HEI), is under contract to purchase the property
from the Wheat Ridge Housing Authority and is proposing to rehabilitate the historic Fruitdale
School for residential use. The adaptive reuse will result in 16 apartments.
No change is proposed to the footprints of the existing buildings, but extensive site
improvements will include grading the site and installation of ground -mounted solar panels,
landscaping, paved parking, and site lighting.
The subject site is comprised of one parcel that is 62,708 square feet (1.44 acres) in size.
Earlier this year, the property was rezoned and platted as part of Case Nos. WZ-16-02 and
MS -16-01.
Please respond to this request in writing regarding your ability to serve the property. Please specify
any new infrastructure needed or improvements to existing infrastructure that will be required. Include
any easements that will be essential to serve the property as a result of this development. Please
detail the requirements for development in respect to your rules and regulations. If you need further
clarification, contact the case manager:
Case Manager: Lauren Mikulak
Phone: 303.235.2845 Email:Imikulak@ci.wheatridge.co.us Fax: 303.235.2845
DISTRIBUTION:
Wheat Ridge Public Works
Wheat Ridge Forestry Division
Wheat Ridge Building Division
Valley Water District
Fruitdale Sanitation District
Arvada Fire District
Jefferson County Public Schools
Xcel Energy
Century Link
Comcast Cable
Vicinity Map
The subject property is located at 10803 W. 44`h Avenue, and it is outlined in blue in the image below.
City of
Wheat c
COMMUNITY DEVELOPMENT
City of Wheat Ridge Municipal Building 7500 W. 291' Ave.
October 4, 2016
Mr. Jim Hartman
2120 Bluebell Avenue
Boulder, CO 80302
Re: Fruitdale Lofts – Site Plan / l' Review
Dear Mr. Hartman:
Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857
This letter is regarding the application for approval of a Site Plan for the Fruitdale Lofts property
which is zoned Mixed -Use Neighborhood (MU -N) and located at 10803 W. 44a' Avenue. I have
reviewed the site plan and have the following comments. Please also refer to the enclosed redlined
copy of the submittal sheets and comments from other departments/agencies.
All Sheets
1. Please correct the spelling of "buried" in the 811 notation on all sheets.
Sheet 1—Cover Sheet/Site Plan
2. Correct the northernmost property line dimension to match with the plat. It should read 1 10'
instead of 110.75'
3. Label the bike rack locations.
4. Provide a detail or other information about the bike rack design to indicate how many spaces can
be provided per rack. For reference, each inverted U -shape bicycle rack is counted as 2 bicycle
parking spaces.
5. Label or remove the storm sewer pipe at the northeast corner of the building.
6. Along the eastern property line adjacent to the parking, does the proposed fence extend south all
the way to 44`h Avenue? Please denote the terminus of the fence. In this same area, please denote
the location/width of the proposed gate.
7. The land swap agreement between the Housing Authority and School District requires that the
fence between the properties be constructed of "mutually agreed upon" materials. Please confirm
that the School District has agreed to the fence design.
8. Is the existing curb cut proposed to be modified? If not, please label as an existing curb cut.
9. A note at the southwest corner of the property indicates a utility easement. Provide a reception
number for the easement or indicate that it will be created by separate document.
10. In the graphic legend, remove the scale bar which conflicts with the scale provided on the bottom
of the sheet.
11. In the Owner's Certificate, please replace the text "Name of owner..." under the signature line
with the name of the person who will sign. This should be Jim's name. We will get the plan to
an approvable point and sign the site plan after closing.
12. In the City Certificate, please modify the text under the signature line so it only reads
"Community Development Director."
wwwxi.wheatridge.co.us
13. Remove the surveyor certificate—a stamp will not be required because the lot dimensions are
based on a recent plat.
14. In the site data tables:
a. Add the address: 10803 W. 44°i Avenue
b. Add case history with the following case numbers: WSP-16-05, MS -16-01, WZ-16-02
c. Round the net area calculation so it matches the gross lot area – the two should be the
same since there is no land dedication that will reduce the lot area.
d. The hardscape, landscape, and usable calculations on the cover sheet do not appear to
match the numbers provided on Sheet 2. Please remove these three categories from the
cover sheet and replace them with the umbrella category of "Open Space." Please also
note that because the property is entirely residential, the open space requirement is 15%.
This appears to be met, but will require a few edits on Sheets 1 and 2.
e. In the summary of gross building area, please distinguish between the ground floor of the
primary building and of the detached unit.
f. Modify the parking summary table as follows:
Parking Spaces
Provided
Required
Total
40
-
Standard
38
Min 16 Max 40
Accessible
2
2
Charging Stations
2
-
Bicycle
8
4
Sheet 2—Landscape Plan
15. In the open space calculations table, please update all calculations to reflect the 15% minimum
open space requirement.
16. Refer to the enclosed redline for a few label corrections.
17. Clarify what the "native seed" mix is proposed to be in the northern portion of the site. How this
part of the property is proposed to be irrigated/maintained?
18. Clarify which trees are proposed to be relocated (this may be provided with a separate exhibit and
or photographs).
19. It appears that the parking lot screening along the southern property line includes primarily Karl
Foerster feather reed grass. Presumably these are cut shorter in the winter. Please consider
adding more variety to provide a year-round parking lot screen.
20. Please note that an irrigation plan will be required with building permit application.
Sheet 6—Building Elevations
21. It appears that the dumpster enclosure does not adequately screen a dumpster. Please clarify what
the dumpster dimensions are anticipated or raise the height to 6 feet to ensure there are no issues
in the future.
22. Please clarify and label the features the 16 units attached to the north side of the blond brick
building. Are these existing or proposed?
Sheet 7—Utility and Grading Plan
23. The northern portion of the site is not included in the grading plan. Will this area be re -graded?
WSP-16-05 / Fruitdale Lofts
Sheet 8/9 – Photometric and Lig_htin Detail
24. It is unclear to me which fixture is being proposed for the ZA and UZ fixtures. Please clarify by
adding a catalogue number to the luminaire schedule on Sheet 8 and/or circling the specific
fixtures on Sheet 9. Visible bulbs should be shielded.
25. Can the freestanding fixture at the eastern entrance be shielded to reduce spillover?
26. In the schedule on Sheet 8, add the height of the fixtures (mounting height for wall -mounted and
total height for freestanding).
Attached are the comments received from other City departments and outside agencies regarding your
Site Plan application:
• Wheat Ridge Public Works: See attached comments from Dave Brossman dated October 3.
• Arvada Fire District: See attached comments from Steven Parker dated October 3.
• Xcel Energy: See attached comments from Donna George dated October 3.
• Wheat Ridge Water District: See attached comments from Kathleen Kadnuck dated
September 21.
• Wheat Ridge Forestry Division: No additional comments—they also had questions related
to Comments 17 and 18 above.
• Wheat Ridge Sanitation District: No comments received.
• Century Link: No comments received.
• Comcast Cable: No comments received.
• Wheat Ridge Building Division: No comments received.
This concludes the summary of comments. Please address each of these comments by revising the
Site Plan accordingly. For questions or clarification on any comments, please feel free to directly
contact any of the Development Review committee members. The next submittal should include one
(1) full size hard copies of the revised drawings, one digital copy of the revised drawings (in .pdf
format), a digital (.pdf) colored version of the elevations, and a response to this letter.
Please note that a subdivision plat is required for construction of townhomes. As previously
mentioned, building permits will not be issued until the plat is reviewed, approved, and recorded.
Similarly to the site plan, this process can take at least a month.
Sincerely,
Lauren E. Mikulak, AICP
Senior Planner
cc: Case File
Jack Brinkley, The Abo Group
WSP-16-05 / Fruitdale Lofts
09/21/18 WU 13:18 FAX 303 424 0828 VALLEY (PATER DIS 0001
VALLEY WATER DISTRICT
12101 wF.,�r 52ND AVENUE
W HFA'r RUX;F:, COLORADO 80033
TELEPHONE 303-424-9661
FAx 303-424-0828
September 21, 2016
I.a.uren Mikulak
Senior Planner
City cif Wheat Ridge
7500 W. 29'h Mcnuc
Wheat Ridge, CO 80033
Dear Lauren;
In response to your inquiry regarding Case No. WSP-16-05, Fruitdalc Site Pltm, Ilic
Valley Water District offers the following comments:
The Valley Water District has the capacity to serve the proposed project.
2. Domestic taps and fire lines will be required to serve the project. The fire line
will require a plan submittal and review through the Valley Water 6istrict and the Denver
Water Department.
3. Should additional fire hydrants be required by the Arvada Fire Protection District,
it would also require a plan submittal and review through the Valley Water District and
the Denver Water Dcpwment along with necessary casements.
4. The developer should remain in contact with the District as the project moves
forward to communicate any changes that may occur during the planning process.
Please feel free to contact me with any further questions.
Sincerely,
0
ath een a rfuc
District Mee Manager
XcelEnergySM
PUBLIC SERVICE COMPANY
October 3, 2016
City of Wheat Ridge Community Development
7500 West 29th Avenue
Wheat Ridge, CO 80033
Attn: Lauren Mikulak
Re: Fruitdale Site Plan, Case # WSP-16-05
Right of Way & Permits
1123 West 3rd Avenue
Denver, Colorado 80223
Telephone: 303.571.3306
Facsimile: 303. 571.3524
donna.l.george@xcelenergy.com
Public Service Company of Colorado's (PSCo) Right of Way & Permits Referral Desk
has reviewed the site plans for Fruitdale. The property owner/developer/contractor
must contact the Builder's Call Line at https://xcelenergy.force.com/FastApp (re ister,
application can then be tracked) or 1-800-628-2121 and complete the application
process for any new gas or electric service, or modification to existing facilities. It is then
the responsibility of the developer to contact the Designer assigned to the project for
approval of design details. Additional easements may need to be acquired by separate
document for new facilities.
Please note there must be adequate clearance of the vegetation from the planned
transformer. This includes placement of the tree near the planned electric line to the
transformer.
As a safety precaution, PSCo would like to remind the developer to call the Utility
Notification Center at 1-800-922-1987 to have all utilities located prior to any
construction.
If you have any questions about this referral response, please contact me at (303) 571-
3306.
Donna George
Contract Right of Way Referral Processor
Public Service Company of Colorado
!t,
X"dow For t8VARon -s-Ana
7903 Allison Way Arvada CO 80005 • 303-424-3012 • 303-432-7995 fax
October 3rd, 2016
Ms. Lauren Mikulak, Senior Planner
City of Wheat Ridge
7500 W 29"' Avenue
Wheat Ridge, CO 80033
Re: Fruitdale, COWR Project #WSP-16-05, AFPD Project #16-120D
Ms. Mikulak:
The referral referenced above was reviewed for compliance with the 2012 International Fire Code
(IFC) as adopted by the City of Wheat Ridge. The Fire District has the following comments
regarding this development plan.
1. Fire protection service
This parcel is currently within the jurisdictional boundaries of the Arvada Fire Protection District
(AFPD). The fire protection services for this parcel are provided primarily by AFPD Fire Station
#2 located at 5250 Oak St.
2. Fire apparatus access -surface
Fire apparatus access roads shall be provided with an approved all-weather surface (concrete or
asphalt). Access roads shall be capable of supporting an imposed load of 85,000 pounds. (2009
IFC Section 502.2.3)
The applicant shall provide acknowledgement and indicate compliance with this requirement.
3. Emergency vehicle access (EVA)
The EVA shall have a minimum width of 26-0 feet. (2012 IFC Section 503.2.1 amended).
It appears that this requirement has been met.
4. Fire apparatus access -turning radius
Fire apparatus access roads shall provide a minimum inside turning radius and an outside turning
radius sufficient to allow navigation of fire apparatus and allow effective fire suppression
operations. A turning analysis of the site, using AutoTURN® or an equivalent program, shall be
provided and indicate that access throughout the site will accommodate fire apparatus as specified
by Arvada Fire. The developer or representative shall contact Arvada Fire Community Risk
Reduction Division for apparatus dimensions for use in the turning analysis (2012 IFC Section
503.2.4).
The applicant shall provide the specifications used for AFPD T-56. The Auto TURN® provided
does not indicate the dimensions used.
5. Emergency access through site
The private roads through the site shall be dedicated on the final plat as "Emergency Access Lanes"
or other similar language as required by the City of Wheat Ridge.
The applicant shall provide acknowledgement and indicate compliance with this requirement.
6. Fire lane signage
Provide a signage plan indicating the location of fire lane signage. The fire lane signage shall
comply with the City of Wheat Ridge Engineering Standards shall be provided on the curb line.
(2012 IFC Section 503.3)
Fire lane signage plan shall be provided.
7. Required fire -flow
Based upon the information provided and assuming wood -frame construction the minimum
required fire -flow is determined as follows for a structure that is 16,355 square feet:
• 1,750 gallons -per -minute
These figures include a 50% reduction in required fire -flow for the indicated installation of an
automatic fire sprinkler system. (2012 IFC Table B105.1 and Section B105.2)
8. Water supply for fire -protection
Fire hydrants shall be installed and/or made operational to provide the minimum required fire -
flow prior to commencing construction above grade. (2012 IFC Sections 507)
The applicant shall provide acknowledgement and indicate compliance with this requirement
9. Fire sprinkler system
The Utility plan indicates a fire line being installed. There is no indication on the plans of a fire
sprinkler system being installed within the structure.
The applicant shall provide clarification on the plans indicating that the building will be
sprinklered
10. Landscaping clearance
A 3-0 foot clear space shall be maintained around all fire hydrants. The space shall be measured
from the top center of the hydrant and there shall be no obstructions directly in front of fire
hydrants. (2012 IFC Section 507.5.5)
All of the trees within this development, shall provide an unobstructed vertical clearance of 13 feet
6 inches for emergency vehicle access (2012 IFC Section 503.2.1).
The applicant shall provide acknowledgement and indicate compliance with these requirements.
11. Premise identification
During construction and upon completion there shall be building signage provided, a minimum of
4 inches high with a 0.5 inch stroke and visible from the street or road fronting that building. (2012
IFC Section 505).
The applicant shall provide acknowledgement and indicate compliance with this requirement.
12. Construction plans
Complete specifications and building construction plans shall be submitted directly to the Fire
District (AFPD) for review and approval at the same time plans are submitted to the Arvada
Building Inspection Division and prior to construction occurring. The developer is encouraged to
contact the AFPD Community Risk Reduction Division to verify plan submittal requirements and
Fire District permit fees prior to plans submittal.
The applicant shall provide acknowledgement and indicate compliance with this requirement.
Please contact me at (303) 403-0477 or via e-mail at stevenparkerAarvadafire.com if you
should have any questions or need further information.
Sincerely,
Steven Parker
Deputy Fire Marshal
City of
,40r W heat �id c
PUBI IC WORKS
Memorandum
TO: Lauren Mikulak, Senior Planner
FROM: Dave Brossman, Development Review Engineer
DATE: October 3, 2016
SUBJECT: WSP-16-05 / Fruitdale Site Plan, 10803 W. 44th Avenue
I have completed my review for the request to approve a Site Plan for the property at 10803
W. 44th Avenue received on September 20, 2016, and I have the following comments:
1. Upon examination of the submitted documents I noticed there was no meaningful
drainage information included; I will be unable to complete my review at this
time.
2. A Drainage Letter and Plan that includes the following shall be required prior to
completion of the Site Plan review by Public Works:
a. Adequate calculations comparing the existing imperviousness with
the proposed amount of impervious surface.
b. What redevelopment category of the Site Drainage Requirements the
project will fall under (based upon the results of a. above),
c. The water quality and/or detention measures being proposed.
d. Sufficient information to verify the design is compliant with the
City's Site Drainage Requirements.
e. If the design will incorporate the Fruitdale Preschool's
detention/WQ facility, written permission from the school district
allowing this must be provided prior to City approval of such a
design.
To Lauren - Fruitdale 10803 W44th Ave Site Plan lst Review.docx
09/21/18 WED 13:18 FAX 303 424 0828 VALLEY WATER DIS 16001
VALLEY WATER DISTRICT
12101 WE:5r,92N1,) AVF,NUF
wFIFff RIIX) F, COLORADO 80033
TELEPHONE .103-424-9661
FAX,VII-424-0828
September 2 I, 2016
Lauren Mikulak
Senior Planner
City of Wheat TRidge
7500 W. 29`h AvcnUC
Wheat'Ridge, CO 80033
Dear Lauren:
In response to your inquiry regarding Case No. WSP-16-05, Fruitdale Site Plan, the
Valley Water District offers the following comments:
The Valley Water district has the capacity to serve the proposal project.
2. Domestic taps and fire lines will be required to serve the project. The fire line
will require a plan submittal and review through the Valley Water District and the Denver
Water Department.
3. Should additional fire hydrants be required by the Arvada Fire Protection Dist i'lct,
it would also require a plan submittal and review through the Vallcy Water District and
the Denver Water Department along with necessary casements.
4. The developer should remain in contact with the District as the project 111ovcs
forward to communicate any changes that may occur during the planning, process.
Please feel free to contact me with any further questions.
Sincerely,
d,
ath een a uc
District Office Manager
HEI
Hartman Ely Investments LLC
2120 Bluebell Avenue
Boulder CO 80302
720-333-0110
October 19, 2014
City of Wheat Ridge
Ms. Lauren Mikulak
7500 West 29th Avenue
Wheat Ridge, CO 80033
Re: Fruitdale Lofts
Response to City comments on Site Development Plan
Dear Lauren,
Thanks very much for a thorough review of the Fruitdale Lofts Site Development Plan (SDP).
I am writing to reply to your enclosed letter and 10/7 conversation regarding the City's comments
on the SDP:
1. The spelling will be corrected.
2. The dimension will be corrected.
3. The bike rack locations will be labelled.
4. A bike rack detail will be provided.
5. The storm sewer pipe will be removed from Sheet 1.
6. The fence details along the eastern property line will be clarified. The only gates will be
at the SE and NW corners of the solar farm area.
7. That fence will be mutually agreed with the School District per the pending MOU that
was issued earlier this week.
8. The curb cut will be labelled as existing.
9. We will add a note that indicates a future easement for the transformer.
10. The scale will be corrected.
11. The owner name will be included.
12. The signature line will be corrected.
13. The surveyor certificate will be removed.
14. The site data tables will be updated and the required bicycle quantity will be revised to 3
per our conversation.
15. The open space calculations will be updated.
16. Thanks for your plant material quantity corrections; those will be included.
17. The native seed mix will be clarified. Per our conversation, that seed will be established
by natural rainfall and periodically maintained to keep the height of grasses/weeds from
blocking sunlight to the lower edge of solar panels.
18. Existing trees to be relocated will be shown.
19. The parking lot plant screening layout will be revised to provide more height in the
winter.
20. The site irrigation plan will be submitted during construction, since that will be a
design/build system.
21. The height of the dumpster enclosure will be raised to 6'.
22. The mechanical condenser units will be deleted from the SDP drawings since the location
of those may shift a bit once we select our mechanical subcontractor.
23. We will show grading for the northern portion of the site.
24. We will clarify light fixture details.
25. The pole light at the building's east entrance is an indirect source/reflector so that will
provide shielding.
26. The height of pole lights will be shown.
Regarding the comments from Dave Brossman:
1. We will include a brief drainage letter.
2. Regarding site drainage information:
a. We will show existing vs proposed imperviousness calculations.
b. Site drainage revisions will be minor and described by the drainage letter.
c. Per our conversation, on-site detention and water quality improvements beyond our
landscaping design will not be necessary for this site.
d. The revised SDP submission should provide adequate information to verify
compliance with drainage requirements.
e. Permission from the School District for a storm drainage connection between the two
properties is pending per the MOU.
We will send Arvada Fire a separate letter on their comments and will contact Xcel/Valley Water
regarding their comments.
The revisions noted above will be incorporated into a revised SDP submission next week,
concurrent with submitting the construction documents for building permit review.
Please let me know if you have any questions or comments.
Sincerely,
HARTMAN ELY INVESTMENTS LLC
Jim Hartman
Manager
Encl: COWR letter dated 10/4/16
Xc: Jack Brinkley, The Abo Group
HEI
Hartman Ely Investments LLC
2120 Bluebell Avenue
Boulder CO 80302
720-333-0110
October 21, 2016
Arvada Fire Protection District
Mr. Steven Parker
7903 Alison Way
Arvada, CO 80005
Re: Fruitdale Lofts
Response to Arvada Fire comments on Site Development Plan
Dear Steven,
Thanks very much for a thorough review of the Fruitdale Lofts Site Development Plan (SDP).
I am writing to reply to your enclosed letter regarding those SDP comments:
1. We agree on the fire protection service boundaries.
2. The fire lane will be designed to support the 85,000 pound loading as requested.
3. We agree that adequate emergency vehicle access has been provided (also see item 5
below).
4. The AutoTURN analysis used the attached fire apparatus dimensions per your 8/9/16
email.
5. The final SDP drawings will show the Emergency Access Lane (fire lane) as shown by
the attached site plan.
6. Fire lane signage will be provided at the north end curb line of the fire lane.
7. The required fire flow information will be shown on the fire sprinkler shop drawings
submitted during construction.
8. Our Contractor will verify compliance with fire -flow requirements prior to commencing
above -grade construction. The fire sprinkler shop drawings noted above will also provide
information regarding the minimum fire -flow rates provided by the existing fire hydrants
east and west of this site.
9. The final SDP drawings will include a note that states that the main Fruitdale building
will be fully fire-sprinklered.
10. The requested minimum 13'-6" vertical clearance under trees for emergency vehicles in
the fire lane will be provided.
11. Minimum signage dimensions will be provided on the final SDP drawings, during
construction and on the completed building as requested.
12. Our architect will submit construction plans and specifications for your review next
week, concurrent with submitting the revised SDP drawings to Wheat Ridge for their
final review.
Thanks again for your review of the SDP drawings. Please let me know if you have any questions
or comments on our responses.
Sincerely,
HARTMAN ELY INVESTMENTS LLC
Jim Hartman
Manager
Encl: Arvada Fire letter dated 10/3/16
Fire Apparatus drawing from Arvada Fire
Site plan dated 8/3/16
Xc: Lauren Mikulak, City of Wheat Ridge
Jack Brinkley, The Abo Group
Tanner Weatherbee, Palace Construction
-11 . . . .
OL lc yi
Cf.'WPO,')'9Oa?l
llV3HM *anN3AV 4itVIS3M COPO I
slAol iivaiinij
af
011 SIN3WIS3ANI A13 NVWIHVH
17-
.....................
............ ... .........
. ...... ... .......... -
EE009 07'300I81V3HM3(1N3AV MVP MM COM
si�oi Tvaimij
011 SiNgWiSgANI A13 NVWISVH
.....................
............ ... .........
. ...... ... .......... -
1 M
I
City of
W heat �dge
PUBLIC WORKS
City of Wheat Ridge Municipal Building 7500 W. 29th Ave.
November 1, 2016
Mr. Kyle M. Godwin, P.E.
Wilson & Company, Inc.
1675 Broadway, Suite 200
Denver, CO 80202
303.297.2976
Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857
Re: First Review Comments of the Technical Memorandum / Final Drainage Analysis, for Case # WSP-
16-05 / Fruitdale Lofts located at 10803 W. 44`h Avenue.
Dear Mr. Godwin,
I have completed my first review of the above document included in the Building Permit Application for
the property at 10803 W. 44`h Avenue received on October 30, 2016, and I have the following comments:
Final Drainage Report (Discussion):
General Comments:
1. Please be advised of the following:
a. If the TOTAL area of disturbance equals or exceeds one (1) acre in size, the following
shall apply:
i. A SWMP with CDPS Permit from the state shall be required.
ii. A water quality facility shall be mandatory pursuant to the Clean Water Act
requirements.
iii. All components required in the outline found in Section VII of the City's Site
Drainage Requirements shall be included.
iv. The "Technical Memorandum" will need to be renamed to "Final Drainage
Report".
b. The TOTAL area of disturbance includes, but not limited to, areas of demolition,
construction, grading, landscaping, and where material storage will take place.
c. The TOTAL area is considered to be the area of disturbance for ALL phases of the
project, even if the time between those phases may be significant.
2. In the Existing and Proposed Drainage Conditions section:
a. State the proposed TOTAL area of disturbance as defined above.
b. If the area of disturbance will remain less than one (1) acre even if multiple phases are
proposed, then this needs to be clearly conveyed in the discussion portion and that no
SWMP or WQ facility will be needed as a result. Please note that to "pass the straight -
face test" with the state, the amount under an acre should be at least a few hundred square
feet, i.e., one (1) percent or about 440 ft2 (since it is only an approximation).
c. Provide the area of existing impervious surface rounded to the nearest square foot that
corresponds to the 51.3% percentage of the overall property. Provide the same for the
area that is proposed for redevelopment corresponding to the 50.7% imperviousness.
d. Include and discuss sub -basin area and runoff coefficient information for both the
historical and developed conditions.
3. If the TOTAL area of disturbance is one (1) acre or more runoff and volume calculations must be
discussed along with the type of water quality facility chosen. Please be advised that if an
infiltration system is chosen
www.ci.wheatridge.co.us
Public Works Engineering
November 1, 2016
Page 2
Final Drainage Report (Appendix):
1. If the area of disturbance equals or exceeds one (1) acre in size you must include all volume and
release calculations needed for the mandatory WQ pond, adhering to the outline found in Section
VII of the City's Site Drainage Requirements.
Drainage Plan (Appendix F):
1. At a minimum you will need to provide:
a. Sub -basin and runoff coefficient information for both the historical and developed
conditions.
b. Grade percent and flow arrows.
2. If the area of disturbance equals or exceeds one (1) acre in size you must include all runoff and
volume calculations needed for the mandatory WQ pond, adhering to the outline found in Section
VII of the City's Site Drainage Requirements.
Please include a PDF of the revised Final Drainage Analysis with the next submittal.
If you have any questions, please contact me at 303.235.2864.
Sincerely,
David F. Brossman, P.L.S.
Development Review Engineer/ City Surveyor
CC: Steve Nguyen, Engineering Manager
Lauren Mikulak, Senior Planner
File
www.ci.wheatridge.co.us
Ftuitdale Lofts FDR Review-Utndocx
Lauren Mikulak
From: Jack Brinkley <JBrinkley@theabogroup.com>
Sent: Wednesday, October 26, 2016 3:02 PM
To: Lauren Mikulak
Cc: Jim Hartman; Susan Ely
Subject: RE: Fruitdale Lofts, Site Development Plan (reply to City comments)
Lauren,
I just dropped of the revised and additional documents requested in your review letter. I believe we addressed
everything but let me know if you have any questions or concerns.
Thanks
Jack
jack r brinkley, ra
p 720.214.7806 1 c 303.902.3317
jbrinkley(a)theabogroup.com
From: Lauren Mikulak [mailto:Imikulak@ci.wheatridge.co.us]
Sent: Wednesday, October 26, 2016 1:40 PM
To: Jim Hartman; Jack Brinkley; Susan Ely
Subject: RE: Fruitdale Lofts, Site Development Plan (reply to City comments)
The only issue that may still be outstanding is item 20 relative to the native seed mix. I thought when we discussed that
you were proposing more than natural rainfall which is negligible and likely insufficient. Please address how this will be
established and not become a weed patch. Landscape maintenance, even for a more naturalized setting, is a high
priority for the City.
Lauren E. Mikulak, AICP
Senior Planner
Office Phone: 303-235-2845
From: Jim Hartman [mailto:iim@hartmanelyinvestments.com]
Sent: Wednesday, October 19, 2016 6:05 PM
To: Lauren Mikulak <Imikulak@ci.wheatridge.co.us>; Jack Brinkley <JBrinkley@theabogroup.com>; Susan Ely
<susan@hartmanelyinvestments.com>
Subject: Fruitdale Lofts, Site Development Plan (reply to City comments)
Hi Lauren,
Thanks very much for the City's thorough review of our initial SDP submission. Our replies to your comments are the
third attached file.
Talk with you soon,
Jim Hartman
Manager
Hartman Ely Investments LLC
2120 Bluebell Avenue
Boulder CO 80302
720-333-0110
-------- Forwarded Message--------
Subject:Fruitdale Site Plan - Review 1
Date:Wed, 5 Oct 2016 14:24:33 +0000
From:Lauren Mikulak <Imikulak@ci.wheatridge.co.us>
Todim Hartman (iim hartmanelyinvestments.com)<iim@hartmanelyinvestments.com>, Jack Brinkley
(JBrinklev@theabogroup.com) <JBrinklev@theabogroup.com>
Good morning,
Attached are comments based on the first review of the site plan application (Case No. WSP-16-05). The landscape plan
was one of the most legible and clear plans we have seen in a while—particularly the usable open space exhibit and use
of different symbols for each tree and shrub. Thank you for that!
You will see that Public Works has requested additional information regarding drainage. We had previously discussed
provision of calculations showing existing and proposed impervious surface. If you have specific questions feel free to call
Dave Brossman directly at 303-235-2864.
Thank you,
Lauren E. Mikulak, AICP
Senior Planner
7500 W. 29th Avenue
Wheat Ridge, Colorado 80033
Office Phone: 303-235-2845
Fax: 303-234-2845
www.ci.wheatridge.co.us
��j t its- kilt
(l V V h(C atl_
1C o -c
- C()MMUNIf1OP"7i\I
CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are
not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received
this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any
network to which your computer is connected. Thank you.
► submitted E
City of planner. In
]��W heat Wiidge be accepted
LAND USE CASE PROCESSING APPLICATION
Community Development Department
7500 West 29th Avenue • Wheat Ridge, CO 80033 • Phone (303) 235-2846
(Please print or type all information)
Applicant Fruitdale School Partners LLC Phone 720-333-0110 Email jim(cD_hartmanelyinvestments.com
Address, City, State, Zip 2120 Bluebell Ave, Boulder, CO 80302
Owner
Address, City, State, Zip
Phone
Email
Contact Jack R Brinkley Phone 720-214-7806 Email jbrinkley@theabogroup.com
Address, City, State, Zip 8025 W Colfax Ave, Lakewood, CO 80214
(The person listed as contact will be contacted to answer questions regarding this application, provide additional information when necessary, post
public hearing signs, will receive a copy of the staff report prior to Public Hearing, and shall be responsible for forwarding all verbal and written
communication to applicant and owner.)
Location of request (address): 10803 West 44th Ave, Wheat Ridqe, CO 80033
Type of action requested (check one or more of the actions listed below which pertain to your request):
O Change of Zone or Zone Conditions Cl Special Use Permit O Subdivision — specify type:
$ Planned Development (ODP, SDP) O Conditional Use Permit O Administrative (up to 3 lots)
O Planned Building Group KSite Plan O Minor (4 or 5 lots)
O Temporary Use, Building, Sign O Concept Plan 13 Major (6 or more lots)
O Variance/Waiver (from Section 26-) O Right of Way Vacation O Other:
Detailed description of request: Development of the existing closed Fruitdale Elementary School site into 16 units of
a mix of affordable and market rate apartments.
I certify that the information and exhibits herewith submitted are true and correct to the best of my knowledge and that in
filing this application, I am acting with the knowledge and consent of those persons listed above, without whose consent
the requested action cannot lawfully be accomplished. Applicants other than owners must submit ower -of -attorney
from the owner which approved of this action on his behalf. F TAMARA D ODEAN I
Notarized Signature of Applicai
State of Colorado }
County of 5t1WS2r.S0
NOTARY PUBLIC
_ STATE OF COLORADO
NOTARY ID 20164015481
COMMISSION EXPIRES APRIL 22,
The foregoing instrument Land Use Processing Application) was acknowledged by me this /9;`day of, 20
Notary Public
To be filled out by staff:
Date received jPQ 4. )° ,
Comp Plan Design.
Related Case No. l.d ilo-D 2 ►'1S-lG 01
Assessor's Parcel No. - 212 -00 -o Jf9
Size (acres or sgft)
Rev 1/22/ 2016
My commission expires q / al /20X
Fee $
Receipt No.
Pre -App Mtg. Date
Current Zoning MU - Al
Proposed Zoning
Case No.
Quarter Section Map Aft D-1
Case Manager M. iS..da.le.
Current Use Schee
Proposed Use /GQnc��r•",.►s
T -