Loading...
HomeMy WebLinkAbout3300 Ames StreetThe City of Wheat midge insDection Check List notes Mid -Roof Notes 1 Company Name; ty =1�- Inspector signature: 1 Y Date of Inspection: /0 � CUSHMAN SCIENCE e>• LLC September 18, 2019 Ames Partners LLC 19510 W. 55th Place Golden, CO 80403 Re: Drilled Pier Installation Observation - Garage 3300 & 3308 Ames St Wheat Ridge, CO 80212 CG Project No. 18-075 195 South Hoyt Street Lakewood CO 80226 303-475-7993 david@cushgeo.com References: Geotechnical Engineering Recommendation Report by Cushman Geoscience LLC, Job No. 18-075 dated July 23, 2018 Foundation Plans by Barton Consulting Services, Job No. 18-209S, dated May 7, 2019 As requested, a site visit was conducted on September 17, 2019 to observe the installation of 13 drilled piers for the garage foundations at the subject site. The elements observed were found to be in general compliance with the referenced design documents. Please contact our office if additional information is needed on this matter. Respectfully submitted, Cushman Geoscience LLC Observed by: Patrick J. Cole Geotechnical Engineer Reviewed by: YC C=ZAjjr O • O� . UaQ ,5 * F -o w 5p00� f , Eric M. Czaikowski, P.E. Senior Engineer Digitally Stamped PDF via email to addressee, printed copies mailed upon request i Digitally signed by Eric M. Czaikowski Eric M. Czaikowsk Date: 2019.09.18 09:45:19 -06'00' The City of Wheat Ridge Inspection Check List Notes Final Roof Notes Company Name: Certified Building Consultpnts J 2 Inspector Signature: Date of Inspection: /,al , l CBC Wheat Ridge Roof Inspection Packet Page 5 of 5 The City of Wheat Ridge Inspection Check List Notes Final Roof Roof Inspection ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A Pass ❑ Fail Flashing for roof and walls ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Q N/A �` Pass ❑ Fail Verify sheathing nail pattern (See Policy and Procedures) N/A ❑ Pass ❑ Fail Crickets and saddles where needed ❑ N/A Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A Pass ❑ Fail Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A Pass ❑ Fall Underlayments must follow 2012 IRC/2012 IBC ❑ N/A Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A Pass ❑ Fail Dripedge shall have min. 2" of overlap ❑ N/A t Pass ❑ Fail Dripedge should extend down min. 2" past roof deck ❑ N/A Y_ Pass ❑ Fail Dripedge shall be mechanically fastened 12" OC N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min. slope 1/4:12 slope must be installed in accordance with the manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shinales Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less than 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min. of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with the sections overlapping a min. of 4" Tile Roof Requirements N/A ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-1/2:12 slope N/A ❑ Pass ❑ Fail Slopes 4:12 and under require double underlayment CBC Wheat Ridge Roof Inspection Packet Page 4 of 5 Company Name: Inspector Signature: Date of Inspection: The City of Wheat Ridge Inspection Check List Notes Mid -Roof Notes Certified Building Consultants CBC Wheat Ridge Roof Inspection Packet Page 3 of 5 N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less than 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof t� N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min. of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with the sections overlapping a min. of 4" Tile Roof Requirements N/A ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-1/2:12 slope N/A ❑ Pass ❑ Fail Slopes 4:12 and under require double underlayment CBC Wheat Ridge Roof Inspection Packet Page 2 of 5 The City of Wheat Ridge Inspection Check List Notes Mid -Roof Roof Inspection ❑ N/A Pass ❑ Fail Structural roof components ❑ ❑ N/A N/A /,',Pass X Pass ❑ Fail Fail Verify that no more than 2 layers of shingles exist ❑ Flashing for roof and walls ❑ N/A Pass ❑ Fail If new sheathing is installed, verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A ass ❑ Fail Verify sheathing nail pattern (see Policy and Procedures) /�ZO N/A ❑ Pass ❑ Fail Crickets and saddles where needed ❑ N/A Pass A, ❑ Fail Verify vent must have boot same gauge as pipe ❑ N/A Pass ❑ Fail Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A Pass ❑ Fail Step flashing shall be min. of 44 piece per shingle poN/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage /❑ N/A Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A Pass o Fail Underlayments must follow 2012 IRC/2012 IBC ❑ N/APass ❑ Fail Verify roof slope for proper damage ❑ N/A 4Pass ❑ Fail Dripedge shall have min. of 2" overlap ❑ N/A � Pass ❑ Fail Dripedge should extend down min. 2" past roof deck ❑ N/A K7Pass ❑ Fail Dripedge shall be mechanically fastened 12" OC AD N/A / ❑ Pass ❑ Fail 90 LB roof roofing shall not be applied to roof slopes less than 2:12 slope. Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 [,a N/A ❑ Pass ❑ Fail Above roof insulation R -25 l N/A ❑ Pass ❑ Fail Below roof residential R-38 �G N/A ❑ Pass ❑ Fail Below roof commercial R-32 �rP N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min. slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications. Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less than 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof t� N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min. of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with the sections overlapping a min. of 4" Tile Roof Requirements N/A ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-1/2:12 slope N/A ❑ Pass ❑ Fail Slopes 4:12 and under require double underlayment CBC Wheat Ridge Roof Inspection Packet Page 2 of 5 a) L a) a M aa) QE =3 :3 cn Z aE E O L L a. a. a_ = o O E EE a � = Q L L X00 r- .f CL a a - L O U L C —_ a N (U Q D _ :3 E�p� NC� C q (c a Cy cis a L O C U E U a)a-+ L cc 0 -0 -0 .. C Co Z U o04 =O .a) a) 0 L C N O �r oEcy)c V) C V U L C —_ (U Q D _ :3 E�p� a) ca a) N > L O C U E U cpm 0— Ea cu cca V L o04 =O .a) a) ... �U)� .c ++ C) CCOa) E -p V) C CV) as "0 O a) E0) ,..0- UCCc — O cm cm U)•a U ca w- -- L U a t E a a o 00 _� = U O O m O �� f Y — p > M a-. a o m Cl) o �, a C -)cc ca �, cmu) p=orn Q—UcEa)c CN N O 00a)00 LL, L C co 'a) — E�� a) C: a) E L a a)o oo3E �a44—)cm coE �0 C C E (n C U L U a) a) a) L D_ — O U 4) Co Oocoomuo ,OEom N E c V v c C-oN1. Yj ) cc O (D UFu O cp OaN a) cZU O N C >+ >+ a) a U U U a)E a) U C L L (Q 42 aaa ���D_�� cuE ccc cfl CD c O — v N D_ � ti > O 0 O CU m E U N `C m a) 0 CL C C p� 0 0 41 C >, a) E O C D - co d O O 0 3 � U •— c O O Q Y L ++ U c mrn Q 3 C) - .S p 0 c40) .� _ C m EEn°' 0 ca y.1 L LL U) ca L •- a (D Q) a) L C as 0oa)oa Oa.'—>' _ c 00 o c-00 d Q O i C a a 0 L. E .0 a 4- (D L v ay t O a) .t5 O u3 N L cn E E .cn O U U (D a) D• L U U .E c O (D 4- O cu a a 3 c a) cn > a) c c Os U O cp c0 rn0) O cn - I— m re trv� Test Notes No notes entered. Flow Equation Parameters - Factory Default Retrotec rCloud Fan Model Retrotec 1000/2000 Fan Serial Number 1 FN002062 Flow equation parameters - B1 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self -referenced fan or when the room pressure is negative. If using a fan which is not self -referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. If PrA is greater than 0 or fan is self -referencing: FP = jPrBj - PrA If PrA is less than 0 or fan is self -referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x IRPI) FP =ran pressure, RP = room pressure Range N K K1 K2 K3 K4 MF Open 0.5214 519.6183 -0.0700 0.8000 -0.1150 1 8.6 A 0.5030 264.9959 -0.0750 1.0000 0.0000 1 12 B 0.5000 174.8824 0.0000 0.3000 0.0000 1 10 C8 0.5000 78.5000 -0.0200 0.5000 0.0160 1 10 C6 0.5050 61.3000 0.0540 0.5000 0.0040 1 10 C4 0.5077 42.0000 0.0090 0.5000 0.0005 1 10 C2 0.5200 22.0000 0.1100 0.5000 -0.0010 1 10 C1 0.5410 11.9239 0.1300 0.4000 0.0014 1 10 L4 0.4800 4.0995 0.0030 1.0000 0.0004 1 10 L2 0.5020 2.0678 0.0000 0.5000 0.0001 1 10 L1 0.4925 1.1614 0.1000 0.5000 0.0001 1 10 flow =(FP -RPxK1)"x(K+K3x FP) xK4 3 1�rerrvL'�'� Test Results Summary Test Type Flow Reference Pressure Time Averaging Corrected Flow Air Changes Per Hour Percent Uncertainty Correlation Intercept Slope Test Results Test Data Set 1 Flow Direction Gauge Location Retrotec rCloud Single Direction Multi Point Blower Door Test 50 Pa 10 seconds 796.18 CFM @ 50 Pa 1.711 2.3% 0.998 48.299 0.716 Depressurize Inside Baseline Pressure, Initial Pa -0.1 -0.1 -0.1 -0.1 -0.2 -0.2 -0.2 -0.2 -0.2 -0.3 Baseline Duration 16 seconds Average baseline -0.17 Pa Measured Pressure (Pa) -15.05 -22.45 -29.34 -37.31 Fan Pressure [1000/2000 - C8] (Pa) 17.51 29.29 42.22 Fan Pressure [1000/2000 - B] (Pa) 13.62 Flow (CFM) 332.47 430.64 518.02 645.41 Measured Pressure (Pa) -45.3 -52.23 -61.26 Fan Pressure [1000/2000 - C8] (Pa) Fan Pressure [1000/2000 - B] (Pa) 17.54 21.03 26.7 Flow (CFM) 732.41 801.98 903.65 Baseline Pressure, Final (Pa) -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.3 -0.3 -0.3 Baseline Duration 14 seconds Average baseline -0.37 Pa Retrotec rCloud Quality Assurance Report Single Direction Multi Point Blower Door Test PASS Your Result: 1.71 ACH50 (796.18 CFM50 * 60 / 27921 ft') Tar et < 4 ACH60 Test Information Test Name Test Date Export id Company Name Technician Name Technician Email Building Information Address City State Zip/postal Code Country Year Constructed Elevation Address Verified? Building Latitude, Longitude GPS validation Estimated Distance From Address Test Equipment Fan Model Fan Serial Number Pressure Gauge Model Gauge Serial Number Environmental Conditions Pre-test Indoor Temperature Pre-test Outdoor Temperature Wind Speed Average Barometric Pressure Test Dimensions Conditioned Floor Area Envelope Area Volume 3300 Ames St 2020-05-05 09:32 AM (MDT) U9DO3JYF Ultimate Heating & Cooling Kyle Massler kyle@uhcdenver.com 3300 Ames St Wheat Ridge CO 80212 United States 2020 5469 ft Yes 39.764028, -105.054404 Latitude/Longitude: 39 763947 -105,054333: Accuracy: 16 ft 27 ft Retrotec 1000/2000 1FN002062 Retrotec DM32 10A 402271 75 °F 55 °F 0 MPH 102.6 kPa 2888 ft2 2559 ft2 27921 ft3 � y °ro °03 oa Oa�nO ops CD ° N rr m (D r; n a a rr �• C" "� m Ck w 4 Z O 'w � p -t M ro z f n p (D rr N�de p y D' fl ff C) = w a s IQ o °ntr Z ° b m ° ° 7CNc� y ee fD m @ m by O o H W N• m0 V]►�CD K m un F-� (D W N r " rrA C rr tv n(DM ° z cc Oa v !:0.fD a � SD 77y 0 0.� Cc��C� w w � o " ri m�,fDd�rn c '� ° m f� N• ° f7 m 7 z H p N p p 0 ~ 0 ct O m �H rr "C o rr n N. P. M � N CEJ O o n p 0 m � Cr s eD '3 0 wQ r 0 0 CD R c CD o rn O O a I� � ARTON Barton Consulting Services, LLC CONSULTING 9249 S Broadway#200, STE 102 info@bartonconsulting.co A"rSERVICES Highlands Ranch, CO 80129 Phone: 303.997.9577 P. E. Schedule Site Observations & Inspections by Text @ 720.458.6658 Feaster Reality June 18, 2020 Attn: Jay Feaster 1415 Park Ave. W. #102 Denver, CO P: 720.891.7916 E: jqy(kfeasterreally.com BCS Project #: 18-209 3300, 3308, 3316, & 3324 Ames St. City of Wheat Ridge, Colorado Referenced: BCS Design Documents Project Number 18-209 As requested, we have provided a review of the referenced design documents as it relates to two select items identified on the detached garage by a representative of the City of Wheat Ridge Building Department. Based upon that review we have provided the following commentary. • The LPI roof I joist framing is an equivalent substitution for the propose 210 TJI I -Joists. No remediation required. • The 2-2x6 garage window headers are adequate to support the applied design loads. No remediation required. We trust this letter meets the requirements for the City of Wheat Ridge Building Department. Please do not hesitate to contact us if you need additional information on this matter. Reviewed and Stamped By: Scott D. Barton, PE Phone: 303.997.9577 - Barton Consulting Services LLC - info@bartonconsulting.co i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax Inspection Type: Job Address: Permit Number: INSPECTION NOTICE ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been mad 14or-remip ection a1-303-234-59: Dat nspec CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTI Inspection Type: Z Job Address: Permit Number: ## `t ,ze �Al? ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yeses When corrections have been made, 9e -inspection online at: httpYAvww.ci.wheatridge.co.uslinspdic , Dam, Inspe f o i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE InspectionType: Job Address: 2 Permit Number: (� ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yew When corrections have been made, se ale for re -inspection online at: http✓/www.ci.wheatridge.co.uslinspeption �. , i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:' Job Address: _ Permit Number:` ( t ❑ No one available for inspection: Time / --..-:P AM/PM Re -Inspection required: Yes'No When corrections have been made, sch .dule for re -inspection online at: http✓/www,ci.wheatridge.co.uslinspecn \ Inspector: i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: P-1 C /" /-'f'/7_/ r` Job Address:�t� Permit Number: //S-) 5 r ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http.I www.ci.wheatridge.co.usAInspection Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: �--� v ` Job Address: Permit Number:, ❑ No one available for inspection: Time �AM/PM Re -Inspection required: Yes,/ ule for re -inspection online at: ,/ No When corrections have been mad httpYAvww.ci.wheatridge.co.uslins _ ctionn 19. t:,. I 4 • . -- ` I i CITY OF WHEAT RIDGE _��9rBuilding Inspection Division (303) 234-5933 inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: \ C> Ci 5 lUe C 4 • /V-- P r E✓i✓ i H �, ` � ��� �'?`G Cir S - ❑ No one available for inspection: Time `7-'0 Re -Inspection required: No When corrections have been made, call for re -inspection at 303-234-5933 Date aul(o Inspector: ` DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: n--) � --4-- Job Address: CSC) -P1f C �> Permit Number: L� l C( C� \ LC, �4 ❑ No one available for inspection: Time AM/PM f Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. usfinspection Date:-)-- Inspector: >" DO NOT REMOVE THIS NOTICE m (A 2§ƒ/%^ 7 \»\7/\ .{ /\ƒ0/f ' ¥ :3 p7 e777-& a§/\\i B4OE$ ®®\\ E\7 \7»77E mem 2m�oo {/G&/\ gaff «w &#D/ «\ CD&¥\ =r 0 CD �_»0 0)0 {\e-32 /gym/#E CD � D D Uj ƒ2§%o »`GQ( ° (DCL Cf, /2 �f > F E@r\= � =D 0 CL0 / �/\ \ /§ § \ /w 9;o Z aged laved uo!uadsul;ooll agp!y;ea4M J9J ivawAepapun alqnop au!nbai uapun pue ZT:ti sadolS Vej ❑ ssed ❑ V/N adols ZtiZ/T Z'u!w a ane4 11e4s alp a4aa:)uoa pue AeIJ Hej ❑ ssed ❑ V/N s;uawajln aa;oob 51!1 „b;o •ulw a 2utddeIJDAO suo!Pas a44 Pm auII moil aqT le u!-;I!nq q!j JDIJaA!p 4selds 4S!q „ q/£ ;o •u!w a pm au!lia;uaa / ayT ww; „g;o 'Mw a puaixa pe4s Su!4sel; AapeA IelaW !lej ❑ ssed ❑ V/N R ;ooj se leua;ew awes ay; aq p qs 8u!4sel} Aallen Ie3aW I1ej ❑ ssed ❑ V/N V ZT:£ ue4T ssal adols uo papelsu! aq jou pegs salsu!gs;oa Ie3aV4 pej ❑ ssed ❑ V/N s;uawaj!n as sal u!4S 3oo21 Ia3aW uo!.Padsu! Ieug ao; Aa13al aq; uo ssaippe a4l gjIm ATuejaem;o jaual s jajnpe;nuew ane4 isnVy •suo!;eaq!aads s uaanue}nuew a4l y;!m aauepjouue ui pallelsui aq jsnw adols Zl:ti/T adols •u!w Odl'WOd3 'uawnl!g pa!}IpoW I!ej ❑ ssed ❑ V/N J2( Z£ -2l lepjawwo:);oa molaq Hej ❑ ssed ❑ V/N �r 8£-21 le!4uaplsaa;oa molag I!ej ❑ ssed ❑ V/N SZ -u uo!;elnsu! jooi anogV Red ❑ ssed ❑ V/N lu ZT:T;o adols •u!w 41!m sop!s aajgl uo uado 'sUodieJ 'soiled 'sa2eueS pape;ap 1uo!jd9ax3 'adols ZI:Z uegj ssal sadols jooi of pa!ldde aq jou lleys lu!}oa;oa 9106 I1ej ❑ ssed ❑ V/N �p—/ JO „ZT paua;se;A!Ieu!ueyuaw aq pegs 9SpaduO I!ej ❑ ssed V/N ❑ pap ;ooi;sed „Z •u!w umop puaixa pinogs agpoduO Ilej ❑ ssed W V/N ❑ deljano „Z;o •u!w aney 11egs a8paduO Hej ❑ ssed V/N ❑ aSewep uadoid jo3 adols;oou Aj!aaA ped ❑ ssed V/N ❑ J81 ZTOZ/Jill ZTOZ mo1lo; Isnw sivawAeljapun ped ❑ ssedV/N 11sa�eds 11em palea4 w ,Z platys jalem pue a:),I!ej ❑ ssedCRi V/N o 95eu!eup jadoud jo; Molle siaddnas A;!aaApej ❑ ssed ❑ V/N CV a1gu!4s jad aaald qxq;o •ulw aq pegs Su!4sel; dajS I!ej ❑ ssedX V/N ❑ paisni jo paeewep aue sgu!4sed ou A}uaA Hej ❑ ssed V/N ❑ sdea lUaA A;uaA 11ej ❑ ssed p V/N ❑ ad!d se agne8 owes;ooq aney;snw Tuan A;uaA 11ej ❑ ssed V/N ❑ papaau aiagm salppes pue S49ND!JJ I!ej ❑ ssed' ❑ V/N(v (sajnpaaoJd pue Aapod Das) wailed peu 9u!4;eags NPaA lied ❑ sse,!�;;e V/N ❑ (paIsnfpe aq;snw uo!;enleA) uo!ld!a:)sap ;!wad a4; w pa;s!I sl 1! le4l A;uaA'papeisu! s! Ou!q;eags mou;l lied ❑ ssed ,}�� V/N ❑ sllem pue;ooj jo; Swgselj Hej ❑ ssed"ra V/N ❑ ;s!xa saigu!gs;o saaAel Z ue4; ajow ou;eqj A;uaA I1ej ❑ ssed V/N 11s4uauodwou;ooi Iejn7pna3S pej ❑ ssed V/N ❑ uo!;aa sul;ooa ;oob-p!W sa;oN;s!-1 j oa40 uo!;aadsul OBp!M ;eaLIM do Aj!3 aql S 30 £ aVed laPed uoilaadsul loon a2pi8;eayM :)gD sluelinsuoo 6wplrn8 pagpoo saloN loom-P!W saloN lsrl 313a4o uo!loadsul aBP!2j 4eo4M to Alm 041 :uo!loedsul to alep :aanleuB!g aoloadsu! :aweN Ruedwoo S 1 p abed laPed uolloadsul;ooa aBpla lea4AAJ90 luawAeliapun algnop ajinbaa aapun pue ZT:b sadols ped ❑ ssed ❑ V/N adols ZT:Z/T-Z'ulw a ane4 pegs apl alanuoo pue Aelp lied ❑ ssed ❑ V/N s;uawm!n OM 400H 8111 „q ;o -mw a 8ulddel19no suolloas aql gllm aull mol; 041 le w-ll!nq q!j jalaaA!p 4selds 48!4 „ ti/E;o wLu a ql!m auipaluao a41 woj; „g;o •ulw apualxa llegs 2ulgsel; AalleA lelaA lie] 13 ssed ❑ V/N ;ooj se lelialew awes a4l aq llegs 2w4sel; Aallen lelaA ped ❑ ssed ❑ V/N ZT:E uegl ssal adols uo papelsul aq lou pegs sal8ulgs;oa lelaA lied ❑ ssed ❑ V/N s}uawa.gn as sal u!4S;o0b Maya uolloadsul leug ao; jallal a4l uo ssarppe aql 4llm A1ueajem ;o jallal s iajnloe;nuew a4l 41!m aouepa000e w pallelsw aq lsnw adols ZT:q/T adols •uiw Odl'A❑d3 'uawnl!g Pa4!poA lied ❑ ssed ❑ V/N ZT:T do adols •uiw 41P saNs aaJ41 uo uado 'sliodaeo 'soiled 'sagejeB papelap 'uolldaax3 :adols ZT:Z uegl ssal sadols;ooi o1 palldde aq lou lleqs 2ul}oo1 pa 91 06 lie] ❑ ssed ❑ V/N 0O paualse; Apeoluegaaw aq llegs a2padlap lied ❑ ssed V/N ❑ „ZT joap;ow lsed „Z •ulw umop pualxa pinoqs a2padp(i lied ❑ ssed V/N ❑ delJano;o „Z •ulw aneg pe4s a8padu(i ped ❑ ssed V/N ❑ aOeulejp iadoid jo; adols;oa A;uaA ped ❑ ssed X V/N ❑ Dal ZTOZ/]al ZTOZ mono} Ism sluawhellapun lied ❑ ssed V/N ❑ saoeds Ilem palea4 ul ,Z p1014s Salem pue aol lied ❑ ssed V/N ❑ a2euleip ladoid io; mope siaddnas AVOA ped ❑ ssed V/N ❑ al2ul4s rad aoaid yxb;o •uiw aq pegs gulgsel} dalS lied ❑ ssed V/N ❑ palsm jo pagewep aje sSwgsel; ou A;laaA lied ❑ ssed V/N ❑ sdeo luaA A;uaA ped ❑ ssed V/N ❑ adld se a2ne2 awes looq aneg lsnw luaA g A;!aaA lied ❑ ssed V/N ❑ papaou a.iagm salppes pue slamou0 ped ❑ ssed ❑ V/N (saanpaooad pue Aallod aas) uaalled lieu 2u141eags A;uaA ped ❑ ssed V/N (palsn(pe aq ism uoilenleA) uolldiaosap l!wjad aql u, st ll legl A;IJBA papelsui sI 2ulgleags mau A Ile] 13 ssed V/N 13sluauodwo-j;ooa palsll lempnils lied ❑ ssed V/N ❑ seem pue;ooi jo; 2ul4seld ped ❑ ssed V/N ❑ ;slxa sal8uigs;o vaAel Z uegl ajow ou legl A;uaA ped ❑ ssed V/N 13a sluauodwoo lolemlonils lied 13 ssed � V/N ❑ u0110a sul}00H sa;oN;s!-! 310843 u0!;oadsul GBP!114804M d0 43 041 S do S abed laved uopadsul;ooa aEpia jeagm :)gD :uoi;oodsul;o a;ed :ain;euft .io;aadsul slu jinsuoo 6uiplm8 p94!jj9C) :auaeN Auedwoo saaoN loom Jeu1=1 sa;oN;s!-I 10043 uoe;oodsul OBPIM WOW Jo AM3 841 SN0liO3dSNl WN01ilGO`d 2JOd LJIAO 33S .....r- �Annw niI I in mnniddw o i jou. 31Jonn gelS-ul / nnoleg jo punoi6aapun aanoO;ON o(3 punoi6aapun aul-I ja;em 90Z apejE:) uo gelS L06 Ued aannogS 96£ joua;ul punoiblapun 6ulgwnld 17OZ y 6upla0 anogy - 6wgwnld gbnoa 176E slleM walS 906 aoua;ul punoi6aapun jamas ZOZ 6ulgwnld g6noa E6£ �_,+ s a � ". _ ,,_. � as;;a-'3'd / 6ul100d EO6 6upla0 anogy- IeoluegoaW g6noa Ll£ QY) scald / suossle0 Z06 sluawwoo jo;oadsul alep suo!loadsul uollepunod aa;aNi Ieola;oal3 06E 6upl90 anogy IeOla10913 g6noa 60£ � Ieola;oa13 g6no2J 80E ja;alni ;suo0 dwaiz6s uopoadsul IIeM aaagS 170E ;oob-pm 90E �� 0 bulgleags loob EOE 6ulgleagS IIeM ZO£ Aoloadsul ale(] suolpedsul g6no-d sluawwo0 .....r- �Annw niI I in mnniddw o i jou. 31Jonn gelS-ul / nnoleg jo punoi6aapun aanoO;ON o(3 suoi;oadsul anogy agl 10 lenoiddy of JolJd alaaouoo rood ION OO punoi6aapun aul-I ja;em 90Z apejE:) uo gelS L06 .aolaa;x3 puna6aapun 6ulgwnld 9OZ joua;ul punoiblapun 6ulgwnld 17OZ y - aolaa;x3 puna6aapun jamas £OZ slleM walS 906 aoua;ul punoi6aapun jamas ZOZ l!npu00/alge0/le0l40913 Jn 60Z �g s;uawwo0 0 oadsul ale suolloadsul gelS / puno.i6japun suoi;oadsul anogy agl 10 lenoiddy of JolJd alaaouoo rood ION OO 3(100 80r � � SS3�aad bJlIW2i3d aao a uol oadsul ue sanba vv- 6ulMopol agl uogoadsul ue anlaoaa of (Ad 656L) 1HOINaIW � q l l b alis loafoid aql uo pa;sod sl paeo sig; ssalun pawaoped aq lou ll!m suoi;oadsul uol;oadsul aql to (ep aql •w,e g ajojeq wao; auiluo eq; ein palllwgns aq;snw suollellaoueo uoiloodsui/sn•oo•96p!aleagnn•io•nnmm//:duq :wjo; auiluo uoiloadsul auO33N N01103dSNI apejE:) uo gelS L06 uol;elnsul Ilene uol;epunod 906 y ,J( ,, slleM walS 906 -Va0 >oeglaS uollepunod 1706 as;;a-'3'd / 6ul100d EO6 scald / suossle0 Z06 sluawwoo jo;oadsul alep suo!loadsul uollepunod 3(100 80r � � SS3�aad bJlIW2i3d aao a uol oadsul ue sanba vv- 6ulMopol agl uogoadsul ue anlaoaa of (Ad 656L) 1HOINaIW � q l l b alis loafoid aql uo pa;sod sl paeo sig; ssalun pawaoped aq lou ll!m suoi;oadsul uol;oadsul aql to (ep aql •w,e g ajojeq wao; auiluo eq; ein palllwgns aq;snw suollellaoueo uoiloodsui/sn•oo•96p!aleagnn•io•nnmm//:duq :wjo; auiluo uoiloadsul auO33N N01103dSNI uo!s!n!Q 6u!plmg ay; /`q a6e1I0n nnol leou;0813 pue;ou;s!e ani ay; Aq pa;aldwoo eje suogoodsul gbnoa;egl alns aq aseald s;!wlad a6e;I0n MO -1 Joj (ouedn000;o uo!;ezuoglne a;n;!;suoo;ou seop uo!;oadsul 6u!pl!ng leUld aq;;o lenouddy panss! s! /ouednoop;o a;eo!;!luau e ajo;aq 6u!pl!n8 pue aulg 's>IaoM o!lgnd '6uluueld /`q panadde pue palaldwoo aq;snw swat! py :a;oN :3(100 sorV� ( �:SS3aaad 5bQ Qb ��P:lIW2�3d snoauellaos!n £Z£ 000nlS/glel/IelaW GOE `' , _.. , a • I ;” )_.� (.G !, jawee jodeNdeaM 9sn0H 7ZE slleM JannogS/paeog ajn;s!oW LZ£ 'loafoad anoA aol loplslp u0110040ad aalj ag; loe;uo0 aseald suo!loadsui a.i!l uoj,,, L98Z-SEZ-£OE Ilea aseald suo!;oadsui a6eweip pue Mpa'slioM a!lgnd Aoj„, 978Z -9£Z -EOE Ileo aseald suog0adsul6u!>fjed pue 6u!deospuel'6uluoZJoj, :aouenpe u! 40ane auo sappue asap; wwl suogoadsu! lsanball I!eN Pue MaJoS IIemj(j(i OZ£ uo!;oadsul leu!j 6u!pl!ng S7 lenaddy asuaoi� ssaulsng umloadsul leulj 6u!uoZ 264 iw6l/ll aaleM iwolS 9L7 ,Ieulj s laoM o!Ignd 947 ,,,u0!10alad aa!j / dsul ad!j 7L7 ,uol;oadsul u!eld poolj SL7 _ „uol;oadsul Plalj Md Z47 6ulddolS aiij L LE Jool)/nnopu!M leu!d W, 7 ;00a leu!j 604 6u!gwnld leu!j 207 leolueg0alnl leulj 907 leo!d;0a13 leu!d E07 sluawwoo slelllul aled joloadsul suo!loadsulleu!j :3(100 sorV� ( �:SS3aaad 5bQ Qb ��P:lIW2�3d snoauellaos!n £Z£ 000nlS/glel/IelaW GOE `' , _.. , a • I ;” )_.� (.G !, jawee jodeNdeaM 9sn0H 7ZE slleM JannogS/paeog ajn;s!oW LZ£ I!eN Pue MaJoS IIemj(j(i OZ£ uopelnsul90£ .. (widwocsuoileileuad)6Ulwejj gbnob LOS �✓+ k3P asealab ja;aW seE) Z07 al ;sal ainssaid au!lseE) LOB 6ulddolS aiij L LE sluawwoD 7ol0adsul a;ep (panu!luoo) suo!loadsul g6noa :3(100 sorV� ( �:SS3aaad 5bQ Qb ��P:lIW2�3d i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes When corrections have been made, c- a%i r re -inspection at 303-234-5933 Datez— 0 InspebtAo DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: �3 -r�� �4A-T� Job Address:�,�-� Permit Number: ❑ No one available for inspection ;,Time4A Re -Inspection required: Yes'; No When corrections have been made, schedule for re -inspection online at: httpYlwww.ci. wheatridge.co.uslinspection Date:—,! : `? - nspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE r. Inspection Type: R),J)C L.� op Job Address: I 33oo nyn t 5 Permit Number: i U G T ❑ No one available for inspection. Re -Inspection required: Ye When corrections have been made, schedule for re -inspection online at: httpYAvww. ci. wheatridge.co. usrnspection Date: 1(,A,: 0 - ` c7 Inspector: )­) �'' DO NOT REMOVE THIS NOTICE ®®� i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: V� 6 fie` Job Address:(�Y'!C_S Permit Number: C-) 0 `m 0, C: Aij � z­�,r, k, ❑ No one available for inspection: Time fit'' AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. ushnspection Date: _ ` \ . \ �, Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:t JobAddress: Permit Number: LA ❑ No one available for inspection: Time-. n�) AM/PM Re -Inspection required: Yes o^ *When corrections have been made, schedule for re -inspection online at. hUp✓/www.ci.wheatridge.co.0sfil nspea�fa - - --- Date: 9 • �� Ind ecto DO NOT R WQ' VE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: K, c , c,, ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: httpYlwww.ci. {whheeatridge.co.uslinspection Date: 1 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:t JobAddress: Permit Number: LA ❑ No one available for inspection: Time-. n�) AM/PM Re -Inspection required: Yes o^ *When corrections have been made, schedule for re -inspection online at. hUp✓/www.ci.wheatridge.co.0sfil nspea�fa - - --- Date: 9 • �� Ind ecto DO NOT R WQ' VE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: K, c , c,, ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: httpYlwww.ci. {whheeatridge.co.uslinspection Date: 1 Inspector: DO NOT REMOVE THIS NOTICE A CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: V" Job Address: o Permit Number: _ ;? C \ C, 0 \ o C, —s VJ J J No one available for inspection: Time t AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http.-Ilwww.ci. wheatridge.co. uslinspection Date:— Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: {�Sv`\ C. �'_k U " Job Address: no C_`� Permit Number: D13 k CA U � CSC, ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. u-%rinspection Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: -'� i 4 s V✓� Job Address: 3'J)G U 4::)-rn E Permit Number: 14(> 01 % 10C.1 E� ❑ No one available for inspection: Time "' L ') AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http://www. cL whea tridge. co. uslinspection Date:. 1 � I Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: i Permit Number: C _r� 6—C 1 [-A No one available for inspection: Time]! M_/PM Re -Inspection required: Yep No;` When corrections have been made, schedule for re -inspection online at: http✓/www. cL wheatridge.co. uslinspecfioiT Date: IkJ F 1 Inspecto ®O NOT RE E THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office 4--,) Z_ &; `r ;�; - INSPECTION NOTICE Inspection Type: �= 1� `��!-��•�� cS Job Address: Permit Number: :_?_ �V) ❑ No one available for inspection: Time �:�/AMIPM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. usrnspection Date: (z , - 61, Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: :�l �, !"I : Job Address:? 2�27�1 A Permit Number: ❑ No one available for inspection: Tirr Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge.co.uslinspection Date:—/ �?• 19 Inspector: ¢'�'�----- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: 45 ❑ No one available for inspection: Tim QEQ(KM__/1PM Re -Inspection required: Des No When corrections have been made, sche ule for re -inspection online at: http//www.ci.wheatridge.co.unspection----_�__ Date/nspect r: l`1 1 A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: U� -`� VQ-A LjL Job Address`` - Permit Number:. q� F' ❑ No one available for inspection: Tim�'p iAI1 PM Re -Inspection required: Yes/',/ No) When corrections have been made, call for re -inspection at 303 -234 - Date:) 15', 03-234- Date:)15', ;2-- Iq Inspector: r---- -- DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE '`Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE .Inspection Type: � Job Address: , ca Permit Number:�'j 44�fz =-:X-&-- ❑ No one available for inspection:.,TimeAM Re -Inspection required: Yes No-,-) When corrections have been made, call for re -inspection at 303-234-5933 Date: 13 Inspector: — DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: lf:!�?--f� Job Address: Permit Number:I ❑ No one available for inspection: Timef _k:) �&/Pm Re -Inspection required: Yes'," No � When corrections have been made, call for re -inspection at 303-234-5933 s^ Date: ( Inspector: --- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTI E Inspection Type: ;�� r&.� Job Address: 33,E E�5 —"-- V_ Permit Number:!' s ❑ No one available for inspection: Time... ANklPM ., ' Re -Inspection required: Ye$ ---No.-,, w: When corrections have been made, call for re -inspection at 303-234-5933 Date: e -7L >� Inspector: k.4- --_ DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 9'� KJ _ L) C4 Job Address: Permit Number:�� ❑ No one available for inspection: Time Re -Inspection required: Yesc When corrections have been made, call for re -inspection at 303-234-5933 Inspector: DO NOT REMOVE THIS NOTICE FOR OFFICE USE ONLY Approved by: l ilv k)l W 1Zc%at I is �gc- Ins for Date City of Wheat Ridge Municipal Building 7500 W. 29h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 FOUNDATION SETBACK AND ELEVATION CERTIFICATION For Commercial and Multi -Family Developments This form must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This form must be accompanied by a Construction Control Plan following the procedure found on the reverse side of this form. DATE: e7 4 PERMIT# o2r 1�]0 1 Q ADDRESS: _ 33oco A.-" �rs S 1 LOT _Z, BLOCK SUBDIVISION SURVEYOR: I hereby certify that the elevations and distances shown on the attached sheets and as stated below for the recently formed or constructed structural foundation for the above property have been measured by me or directly under my supervision. The MINIMUM SETBACK DISTANCES from the property lines have been determined to be: FRONT: - Z4 05 . REAR: 7&1 zy SIDE: 8 Zy SIDE: t6 The foundation corr ELEVATIONS (NAVD88) have been determined to be: 7 FRONT: syr= REAR: S 6 S 7I_ 5 SIDE: " G S ? y SIDE: s_`/6 a -7-- All measurements have been determined on the following location: (Check only one): Top of proposed foundation wall prior to placement of concrete -Top of foundation wall subsequent to placement of concrete The Signed Professional Surveyor Print Date o are included on the attached Construction Control Plan. JV . 38m Rev 11/2019 i CITY OF WHEAT RIDGE Building Inspection` Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE r" Inspection Type: f-2�—- Job Address: Permit Number: I ❑ No one available for inspection: Time ti JAM/AM Re -Inspection required: Yes;" I: o_) When corrections have been made, call for re -inspection at 303-234-5933 Date:Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:�� Job Address: a?22.�ne.s f Permit Number: -7>C> ❑ No one available for inspectioa�_Tirne( _�PM Re -Inspection required: Ye�No When corrections have been made, cAltl -inspection at 303 -234 - Date:. �rJej'Inspector: - DO NOT REMOVE THIS NOTICE N* i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax Inspection Type: INSPECTION NOTICE L-; r-, \ \ Job Address: UCSD Permit Number: C-) C) O'D e- 0 V ❑ No one available for inspection: Time AM/PM Re -Inspection required: e No When corrections have been made, call for re -inspection at 303-234-5933 Date: i��- L , I c' Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 103— ] Job Address: =^� Permit Number: fl - ❑ No one available for inspection: TiME Re -Inspection required: Ye6No When corrections have been made, call for re -inspection at 303-234-5933 Date: . ---.;v--?" �' '�' Inspector: DO NOT REMOVE THIS NOTICE `®®s CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office o (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: U Job Address:' -- Permit Number: , C� 1_ �', (�; ( ) C, `a r ( ❑ No one available for inspection: Time AM/PM Re -inspection required: Ye(� No When corrections have been made, call for re -inspection at 303-234-5933 Date: = ,�� ' Inspector: ' ®O NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number:`? ❑ No one available for inspection: Time/4' AM/PN Re -Inspection required: YeNo� When corrections have been made, call for re -inspection at 303-234-5933 Date: p/ Inspector: c p DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: ~' C� ✓'ri C Permit Number: ❑ No one available for inspection: Time " AM/PM f, Re -Inspection required: lies No When corrections have been made, call for re -inspection at 303-234-5933 Date: ,` ! Inspector: iJ DO NOT REMOVE THIS NOTICE City of Wheat Ridge Duplex - New PERMIT - 201901095 PERMIT NO: 201901095 ISSUED: 07/08/2019 JOB ADDRESS: 3300 Ames St EXPIRES: 07/07/2020 JOB DESCRIPTION: New 2 story duplex with unfinished basement - 1,930 sq ft total with 830 sq ft detached garage *** CONTACTS *** OWNER FEASTER JAY GC (303)369-7977 TOMMY CAGLE SUB (303)522-3872 LUIS MORGAN SUB (720)272-1288 DIEGO TELLEZ SUB (303)289-2070 LLOYD LADD MATTHEW ROBLEDO 190113 Q BUILDERS, LLC 110057 PROLINE PLUMBING LLC 120187 L&D ELECTRIC LLC 090062 ULTIMATE HEATING & COOLING LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 425,000.00 FEES Total Valuation 0.00 Plan Review Fee 2,098.40 Use Tax 8,925.00 Permit Fee 3,228.30 Engin. Review Fee 150.00 ** TOTAL ** 14,401.70 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. work is subject to field inspections. As part of the foundation inspection and PRIOR to the placement of concrete and before proceeding with any further construction, a completed, signed and sealed, Foundation Setback and Elevation Certification shall be submitted to the City for review. The certification form shall be fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating that the foundation was constructed in compliance with all applicable minimum setback and elevation requirements of the City. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Prior to project completion or granting of a Certificate of Occupancy, an As -Built Survey or Improvement Survey Plat shall be submitted to the City. Landscaping removed or damaged during construction must be replaced prior to final inspection. No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development lOMS- prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 125% of the cost of the installation shall be required. ROW permit required for sidewalk construction. I, by in signature, do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am tl�e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am leggally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or �;6id'fRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying Flans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Budding Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regilition of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Offlcigf Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. �6A41 City of i�?�WhcatP dge CommuNrry DEVELOPMENT Building & Inspection Services 7500 W. 29t1 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a-)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: aq�cq Plan/Permit # Clqp)oq� Plan Review Fee: �/ 0 Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3300, MME, Ames St. Wheat Ridge, CO Property Owner (please print): Jay Feaster Phone: Property Owner Email: jayCofeasterrealty.com Tenant Name (Commercial Projects Only) Property owner Mailing Address (if different than property address) Address: 19510 W. 55th PI. City, State, Zip: Golden, CO 80403 Arch itectlEngineer: Michael Fiebig, AIA / Fiebig Architecture Architect/Engineer E-mail; michael@fiebigarch.com Phone: 303.594.7584 Contractor Name: Tommy Cagle / Q Builders LLC City of Wheat Ridge License #: 190113 Contractor E-mail Address: gbuilders123@a gmaii.com Phone: 303.369.7977 'For Plan Review Questions & Comments (please print) CONTACT NAME (please print): Jesse Donovan Phone: 720.504.8629 CONTACT EMAIL.(please print): jesse@brightlightereng.com Sub Contractors (Must provide Wheat Ridge License No +& Signed Subcontractor Authorization form) Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. ❑COMMERCIAL ❑X RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Project includes construction of two new duplexes (4 units) on the existing 18,762 SF parcel. Each duplex will be 3,860 SF gross above -ground square footage (two stories) and have a 1,930 SF footprint. The duplexes will include unfinished basements with rough plumbing for future build -out. Each duplex will have an 830 SF detached garage. The lot size will be 56'x151' for a total area of 8456 SF per duplex. Included with the duplexes will be site work (approved through the ODP and SDP and Plat process) including a private alley, infiltration pond on a separate 1,850 SF tract, and new curb, gutter, and sidewalks. The current site is bare ground with no improvements on site. t�) 1JAL"y1v Sq. FULF '1 BTUs Gallons Amps Squares For Solar: Kw # of Panels Requires structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) 1,700,000 for the entire project ($425,000 per application) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or AUTHORIZED REPRESENTATIVE of OWNER (CONTRACTOR) Signature (first and last name): _ ' z, DATE: 5/29/2019 Printed Name: Jesse Donovan DEPARTMENT USE ONLY ZONING COMMMFNTS: Q,.I_vl Reviewer: !2�e A19 ('7049 4 / 4 /('? BUILDING DEPARTMENT COMM TS: Reviewer; 6jt3II� OCC fPANCY-CLA'SWICK"PON: 2? CONSTRUCTION TYPE: PUBLIC WORKS COMMENTS: d) 420C.'r 11__IFAI1 j c7CWN'��TS _ rep Reviewer: Building Division Valuation: City of CITY OF WHEAT RIDGE BUILDING AND INSPECTION SERVICES DIVISION 7500 W 29th Ave Wheat Ridge, CO 80033-8001 p. 303.235.2855.f 303.237.8929 Proof of Submission for Permitting/Plan Review (Water and Sanitation only) A copy of this form must be completed by each water and sanitation agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: Project Address: Name of Firm/Individual submitting documents: Type/Description: Signature of Firm Representative or Individual: s1�4,eX- I, ([ ks &"P— , am a duly authorized representative of the agency indicated beloVand do, by my signature below, hereby acknowledge receipt of documents necessary for review and approval df the project indicated above. Agency represented: (Please check one) Wheat Ridge Water District o Consolidated Mutual Water District o Valley Water District o Denver Water Agency Notes: • Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District o Westridge Sanitation District o Other Signatur Date: (Agency Repre I entative) 4. 9 $ City of `` idgc CITY OF WHEAT RIDGE BUILDING AND INSPE'TIION SERVICES DIVISION 7500 W 29th Ave Wheat Ridge, CO 80033-8001 p. 303.235.2855.f 303.237.8929 Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: �', ► 3- M Project Address >3Do- 330$- 311• 5r3 Name of Firm/Individual submitting documents Project T JhL Signature of Firm Representative or Individual: DO NOT I, C)"A qfl 4i A - and do, by my signature below, hereby ac the project indicated above. Agency represented: (Please check one) o West Metro Fire Protection o Arvada Fire Protection o Wheat Ridge Water District o Consolidated Mutual Water District o Valley Water District p, Denver Water Agency Notes: 4 Id THIS POINT - FOR AGENCY USE ONLY am a duly authorized representative of the agency indicated below vledge receipt of documents necessary for review and approval of o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District o Westridge Sanitation District o Other -3 9 oa , ¢1., , 3 3 O B, 3114 Signature: Date: gency pres tive) City of Wh6atj�idge COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Sub c tractor's ance and I'Mnse must be up to date prior to permit issuance. Sao— Project Address: 3 3W 14 01W5 Permit #: General Contractor: Electrical Sub -Contractor Company Name: State License #: Wheat Ridge License #: Signature of Authorized Agent Plumbing Sub -Contractor Phone #• Master #• (required field) Date Company Name: rf C ,i yam' &Mb m Phone #: G S ,� u - 3r 72 - State License #: 2 i ` q Master #: LK 69 Z. Wheat Ridge License #: I0 C> 5'7 .._...._.__(required field) Signatu e o Authorized Agent Date Mechanical Contractor Company Name: Wheat Ridge License #:_ Signature of Authorized Agent Phone: _ ____ ...,(required field) Date City of Wh,6at COM � �� " � " SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form wiR not be accepted with misiing information. :Subcootraetor's City of hcxt Ridge Lk*msc�wmbev iumst bye -provided in the a"file .space. Subcnntractc r_s `insurance and lUmuse most -be ap -to date prier to permit ids*rice. Project Address: ;500, :�;�t�Y;�-�{„ "�1{ 'Permit #: — General Contractor: Electrical Snub -Contractor camparry Name- � V `l c.. . Pirrrrre #._..:� - 2 State License #: Master #:�L2 Sign atu of Aa riztd Agent arse Plumbing Sub -Contractor Compa Name-. Phone ##:. ,State License-#: ?gaster #: Wheat i2idge License #:(required tielc#) S g otvry -f Awthoriaed Agent I oaltc Mechanical Contractor Company Name: Phone: requi-red frebij. Signature of Authorized .Agent Date City of IF V h6 COMMUNITY "."j" 49-C 0m t UNiTy DEVELOPMENT This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 3;, 33pye�3 .3-3 2- Permit e15- .51-71— General Contractor: (?5 2 _. o,,< - Electrical ,,<- Electrical Sub -Contractor Company Name: State License #: Phone 9: Master #: Wheat Ridge License #: (required field) Signature of Authorized Agent .Plumbing Sub -Contractor Company Name: State License #: Wheat Ridge License M Signature of Authorized Agent Mechanical Contractor Date Phone #: Master #: _(required field) Date Company Name:Phone: Coo, 0 M�*mt Ridge License#: %Cj) —(required field) LI S/ gnature of Authorized Ag�ht Date Jesse Donovan From: Kral, Bruce Sent: Monday, April 29, 2019 3:22 PM To: Jesse Donovan Cc: Keith, Wayne; Charlie Keener Subject: RE: 3300 Ames - West Metro Submittal Attachments: 2019_03_26 AMES SDP REV3.pdf; 3300 AMES - CD.PDF Hello Jesse, Based on a preliminary review - The proposed access from the public streets and alley provides adequate fire access. The existing fire hydrant is acceptable for the required fire flow. Permits are required from the fire district for non-residential core and shell, all work on automatic fire protection systems, all work on automatic fire detection systems, underground fire line and for the storage of hazardous materials. WMFPD reserves the right to provide additional comments/requirements at the time when plans are formally submitted and reviewed per applicable codes and amendments. Bruce Kral, CFO Fire Marshal West Metro Fire Protection District 433 South Allison Parkway Lakewood, CO 80226 (303)989-4307 ext. S13 bkral@westmetrofire.or� Fire is Everyon,W# t^VM- This email is not intended to provide approval of any design elements. The comments contained herein are only offered for use by the designer and are based on conceptual ideas and not a thorough review. Approval will only be provided upon the submittal of formal plans for review. Further comments and requirements may be provided at that time. From: Jesse Donovan[mailto:jesse@brightlightereng.com] Sent: Wednesday, April 24, 2019 5:25 PM To: Kral, Bruce Cc: Keith, Wayne; Charlie Keener Subject: 3300 Ames - West Metro Submittal Bruce, I believe we sent this site to you for review previously, but we wanted to double check. See attached for the CD set as well as the elevations for the proposed two duplexes at 3300 Ames. Thanks, Jesse Donovan, PE I Principal Brightlighter Engineering LLC 1 720-504-8629 direct 3253 N. Gaylord Street, Denver, CO 80205 iesse@brightlightereng.com I www.brightlightereng.com !!!! CAUTION: This email originated from outside West Metro Fire Rescue's email server. Do not click links or open attachments unless you recognize the sender and have positive sender verification of the purpose of this email. Never enter USERNAME, PASSWORD or sensitive information on linked pages from this email. !!!! RESIDENTIAL Building Permit - Plan Review Worksheet Address: _ 33D01 �'� a $ 3 31 b 5324 Lot Size: sq. ft. Rev. 09/2017 -� Q�rwedl Zoning: �� �/ W*- t8-zs/�6 Lot Width: lil Property in the flood plain? If yes, notify PW Floodplain Administrator and add surveying condition FLD Subdivision: J;;. C,-, 4e,,(- Any conflict? (Y/N) C& -gyp 1'\,e3 w ( T (Z N) Related Cases: A&IZ - l$_2 S / 26 , NlS - V6 - 0 Type of project (applicable survey conditions in parenthesis): Maximum Lot Coverage: q- 0 % Existing Improvements (footprints): House: sq. ft. Shed: sq. ft. Detached garage: sq ft. Other: sq. ft. Total Existing sq. ft Lot Coverage % sq. ft. Proposed Improvements (footprints): House/addition: sq. ft. Shed: sq. ft Detached Garage: sq. ft. Other: sq. ft. Proposed+Existing Lot Coverage Required Setbacks: FR S S R Provided Setbacks: FR S S R sq. ft For additions or new construction, is the structure within 2 feet of minimum setbacks? If yes, add surveying condition FND. Maximum Height: I- ft. Proposed Height: Its g ft. N Maximum Size: Proposed Size: sq. ft. sq. ft. Does the bulk plane apply? (Y/N) If yes, does it meet on all sides (Y/N): FR S S R (See 26-642 and 26-120.C.1 — applies to all single-family structures (new, addition, accessory) in R -1C and R-3) Parkland Conditions Does the permit result in a new dwelling unit (new structure or conversion from non -res use)? If yes, have parkland dedication fees already been paid (eg with a previous land use approval)? If fees are owed, add condition PFEE, notify owner, notify building division, enter fee amount in ADG. Rev. 09/2017 Streetscape Conditions Does the permit result in any of the following conditions? ❑ Construction of new roads ❑ Platting of new lots ❑ New development ❑ Additions that increase gross floor area (not just the footprint) by 60% or more (proposed floor area — existing floor area ) / existing floor area = % increase If any box above is checked... For SF/DUPLEX—Is there existing ❑ Curb ❑ Gutter L15 -ft+ sidewalk adjacent to the property? If curb, gutter or sidewalk is missing, streetscape construction or fees -in -lieu will be required. MULTIFAMILY—Does the frontage meet current city standards? If not, streetscape construction or fees -in -lieu will be required. PRW Fees -in -lieu of dedication or construction are due at the time the permit is issued. 7 Access onditions (apply to all new driveways, garages, additions, or new homes/units) For one and two-family dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. ❑ For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer than 25' to any property line, except when used as joint access for two or more lots. ❑ In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. ❑ One and two-family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. ❑ For all uses, one access point per property is permitted. Landscaping Conditions (apply to additions and new dwelling units) ❑ For one -and two-family dwellings, one tree for every 70 feet of street frontage is required. Frontage of lot - width of driveway _� / 70 = (round up for required trees) Street trees required: Street trees provided: ❑ 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance of C.O. ?�In the event that landscaping cannot be installed due to inclement weather prior to the issuance of a C.O., an escrow agreement with financial guarantees may be allowed to ensure future installation. 125% of the cost of the proposed improvements will be required with the agreement. These funds will be reimbursed back to the roperty owner or contractor once the improvements are in place. ` „ _� c c Dwelling Unit cpt> 's Tc-_�'5 p(,k ❑ Not approved as an independent dwelling unit. 42000 loqs-341 01 Oq ? CUSHMAN GEOSCIENCE & LLC Geotechnical Investigation and Foundation Recommendations 3300 Ames St Wheat Ridge, CO 80212 Project Number 18-075 July 23, 2018 Prepared For Ames Partners LLC Attn: Jay Feaster 19510 W. 55th Place Golden, CO 80403 Cushman Geoscience LLC 195 S Hoyt Street, Lakewood, Colorado 80226 303-475-7993 david.cushmangeo@gmail.com y CONTENTS Scopeof Work...............................................................................................................................................1 Existing Construction and Site Conditions....................................................................................................1 ProposedConstruction.................................................................................................................................1 SubsurfaceInvestigation...............................................................................................................................2 SubsurfaceConditions.................................................................................................................................. 2 LaboratoryTest Results................................................................................................................................ 3 Discussion of Expansive Soils........................................................................................................................3 SitePreparation............................................................................................................................................4 SiteExcavation.............................................................................................................................................. 5 Foundation Recommendations.....................................................................................................................5 Alternative Basement Foundation Recommendations........................................................................................6 FoundationWalls.......................................................................................................................................................7 FloorSlabs.....................................................................................................................................................7 SubsurfaceDrainage..................................................................................................................................... 8 SurfaceDrainage...........................................................................................................................................8 ExteriorFlatwork...........................................................................................................................................9 Radon............................................................................................................................................................ 9 Mold.............................................................................................................................................................. 9 CrawlspaceRecommendations.....................................................................................................................9 Limitationsand Exclusions............................................................................................................................9 References..................................................................................................................................................10 Tables Table 1: Subsurface Conditions Summary ......................... Table 2: Groundwater Summary ........................................ Table 3: Laboratory Test Results Summary ....................... Table 4: Summary of Risk Categories ................................. Attachments Figures Appendix A Appendix B ........................................................................... 2 ........................................................................... 2 ........................................................................... 3 ........................................................................... 4 Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 cx" d ��009a *o0 A609 V001 Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 1 As requested, Cushman Geoscience LLC (CG) has prepared geotechnical engineering recommendations for the proposed residential structures planned for the subject site. Scope of Work The scope included drilling exploratory boring(s), obtaining soils and/or bedrock samples at intervals in the bore holes, and subjecting the samples to various laboratory tests as outlined herein and providing geotechnical recommendations. The recommendations presented herein are based on the subsurface conditions observed in the boring(s) and the laboratory testing results. Additional subsurface exploration and/or laboratory testing may result in recommendations that may differ to some degree than those presented herein. There is no guarantee or warranty as to the uniformity of subsurface materials and conditions at the subject site. An additional discussion of the limitations of geotechnical engineering is included in Appendix A. As noted in the appendix, this report should be considered valid for 3 years after issuance. Existing Construction and Site Conditions The site is currently a vacant lot. At the time of the investigation the lot was vegetated with a good cover of wild plants and grasses. The ground surface slopes gently to the north. Surficial Geology on the site is mapped as Loess (windblown silt with fine sand and clay) according to "Geologic map of the Arvada quadrangle, Adams, Denver, and Jefferson Counties, Colorado" by R.M. Lindvall, USGS Map GQ -1453, 1979. Bedrock below the upper soil appears to be Denver and Arapahoe Formations of Paleocene and Upper Cretaceous age. A geologic map is shown in Figure 1.1 Proposed Construction Planned construction for the site includes two duplex structures with detached garages. The duplexes are proposed to be two stories over a basement and the garages to be one story with a slab on grade floor. The structures will have reinforced concrete foundations and will be built with wood and/or steel framing and possible veneer materials. Structural loading will be relatively light consistent with the proposed construction, on the order of 300 to 3,000 pounds per linear foot. Site grading will be minimal. An existing site plan is presented on Figure 1.0. If the proposed construction varies significantly from that described above or herein, CG should be notified to re-evaluate the recommendations provided in this report as necessary. City of Wheat Ridge Building Division Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 2 Subsurface Investigation The subsurface investigation was performed by drilling three (3) test borings (B-1, B-2, and B-3) on the lot at the approximate locations shown on Figure 1.0. The test borings were drilled on May 18, 2018 using a 4" diameter solid stem auger, powered by a CME -45 drill rig. As noted in the Boring Log, Figure 2.0, samples were obtained using a "modified California" sampler. The samples were obtained by driving the sampler into the subsurface materials at selected depths during drilling. The modified California sampler is a steel barrel sampler with a 2.5 -inch outside diameter and a 2 -inch inside diameter that is fitted with 4 -inch long brass liners during sampling to facilitate retrieval and transport of relatively undisturbed samples of the subsurface materials. The sampler was driven into the subsurface materials using a 140 -pound hammer falling through a height of 30 inches. The number of blows required to drive the sampler 12 inches is recorded and provides an indication of the relative density of granular materials and relative consistency of cohesive, fine grained soils. Subsurface Conditions Subsurface conditions encountered in test borings, B-1, B-2, and B-3, are summarized in Table 1 below. A log of the test borings is presented on Figure 2.0. Note: all measurements are approximate based on tools and methods used in the field. Table 1: Subsurface Conditions Summary Boring No. Depth (feet) Soil Description B-1 0-2 Clay, silty, sandy to very sandy, scattered gravel, hard, moist, brown B-2 2-6.5 B-3 0-8 B-1 2-4 Gravel, silty, clayey, moist, brown B-2 0-2 B-1 7 7 -- 30 Sandstone/Claystone bedrock, intermixed and interlayered, very hard, moist, brown, gray, olive B-2 — 20 B-3 8-20 Groundwater encountered during drilling and measurements after drilling are summarized in Table 2 below. Note: all measurements are approximate based on tools and methods used in the field. Table 2: Groundwater Summary city of Wheat Rid9e Building Division Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 3 Boring No. Time Relative to Drilling Groundwater Depth (feet) Caving/Mud Depth (feet) Swell Potential N During drilling dry - B-1 10 minutes after dry open 10,300 3 days after 28 28.6 13.9 During drilling dry - B-2 10 minutes after dry open 112 3 days after 19.8 20 B-2 During drilling dry - B-3 10 minutes after dry open 9 3 days after dry 19.7 Laboratory Test Results Samples obtained during the geotechnical exploration program were returned to our laboratory where the soil descriptions and boring log were reviewed by a senior geotechnical engineer or senior engineering geologist. Selected samples were then tested in the laboratory for moisture content, dry density, and swell -consolidation potential. Results of the laboratory tests are presented next to the boring log in Figure 2.0 and in Table 3 (below) and in Figures 3.0 — 3.9. Table 3: Laboratory Test Results Summary Boring No. Depth (feet) Moisture Content N Dry Density (pcf) Swell Potential N Swell Pressure (psf) Swell Risk B-1 4 12.4 111 4.1 10,300 high B-1 9 13.9 118 -0.2 N/A low B-1 19 19.5 112 1.0 3,200 low B-2 4 10.1 111 2.4 4,700 moderate B-2 9 18.3 111 0.1 1,600 low B-2 14 21.2 106 0.8 4,700 low B-2 19 18.0 106 0.3 1,400 low B-3 4 11.9 106 1.8 2,700 low B-3 9 9.6 113 0.0 N/A low B-3 19 1 15.8 1 113 -0.2 N/A low Discussion of Expansive Soils The amount of volume change that results when a sample of soil or bedrock is inundated with water under a constant pressure is measured in the Denver swell -consolidation test as the swell/expansion or consolidation potential. The swell pressure is the amount of pressure that is then required to compreFF ly of the sample back to the volume before inundation. Wr,eut midge Building Division Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 4 The geotechnical engineering practice in the Colorado Front Range area uses a relative classification to evaluate the expansion potential of soil and bedrock. The expansion potential is categorized as low, moderate, high, or very high based on the swell potential. The following table presents the relative classifications. Additional information regarding risk is presented in Appendix A. Table 4: Summary of Risk Categories Slab Performance Risk Category Representative Percent Swell (500 psf Surcharge) Representative Percent Swell (1000 psf Surcharge) Low 0 to< 3 0 to< 2 Moderate 3 to < 5 2 to < 4 High 5to<8 4to<6 Very High 8 or greater 6 or greater Source: Colorado Association of Geotechnical Engineers, 1996. Note: The representative percent swell values presented are not necessarily measured values. Rather, they are a judgment of the swell of the soil and bedrock profile likely to influence slab performance. Site Preparation Prior to site grading, areas to be graded should be stripped of surface vegetation, topsoil, debris and other deleterious material. Stripped materials should be wasted off site in accordance with applicable regulations. However, non -hazardous stripped soil with vegetation can be used as shallow fill in non- structural, landscaped areas of the site. All manmade fill or demolition debris should be removed from below the planned foundations and floor slabs, and replaced with properly compacted structural fill. Structural Fill Material: Imported structural fill material should be non -expansive at the recommended placement moisture content and density, classify as a coarse-grained material (sand or gravel) by the Unified Soil Classification System (USCS), and have a liquid limit less than 40 and a plasticity index less than 20. Frozen material, ice, snow, cobbles and boulders larger than 3 inches, debris and other deleterious material should be excluded from fill materials. CG should be contacted to test and evaluate whether proposed on-site or imported materials are suitable structural fill. Suitable imported structural materials would be: CDOT Class 5 or 6 road base, CDOT Class 1 Structure Backfill, or a manufactured 'crusher fines' material. Imported materials should be approved by the Geotechnical Engineer. Fill Placement: Structural fill should be placed in lifts 8 inches or less in loose thickness, moisture conditioned and compacted to 95 percent or more of the standard Proctor Maximum Dry Density (MDD). Fill which classifies as silt, sand or gravel by the USCS should be moisture conditioned to within 2 percentage points of Optimum Moisture Content (OMC), and fill which classifies as clay by the USCS should be moisture conditioned to within OMC to 4 percentage points above OMC. Fill in non-structural areas should be compacted to at least 90 percent of the MDD. City of Wheat Ridge Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Building Division Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 5 Site Excavation The sandy, silty, clay soils classify as Type B soils per the OSHA Excavation Guide. All excavation slopes are to be laid back per the OSHA Excavation Guide for Type B soils at a maximum 45 -degree angle (1:1 Horizontal to Vertical). The excavations should be performed under the supervision of the contractors `Competent Person' per the OSHA Excavation Guide. The slopes may require to be further laid back if seepage or instability is observed in the foundation excavations. The contractor should manage construction traffic and the placement of excavation spoils to maintain excavation slope stability. If site constraints prevent appropriate excavation sloping, the foundation excavation can be shored using drilled concrete piers. Our office can prepare an excavation shoring design for this project if needed. Foundation Recommendations Due to the potential for significant differential movement for shallow foundations, the safest foundation type for the proposed structures is straight shaft, steel reinforced, concrete piers drilled into the underlying bedrock. The following recommendations should be followed in the design and construction of the foundation system. 1. Piers initiated within 3 feet of the existing ground surface (i.e. garage, porch, and crawlspace levels) should have a minimum length of 18 feet and a minimum bedrock penetration of 6 feet. Piers initiated 8 to 10 feet below the existing ground surface (i.e. basement level) should have a minimum length of 12 feet and a minimum bedrock penetration of 6 feet. All piers shall have a minimum diameter of 12 inches. 2. Piers should be designed for an allowable end bearing pressure of 37,000 psf and a side shear resistance of 2,500 psf for the portion of the pier in bedrock. Side shear resistance should be ignored for the upper 5 feet of the pier shaft and the bottom pier diameter, or 1 foot for a 12 -inch diameter pier. 3. Piers should be reinforced the full length as recommended by the structural engineer. Reinforcing should be adequate to resist an uplift pressure of at least 45,000 pounds per foot of pier diameter. 4. Grade beams between piers should be provided with a minimum 4 -inch void space at the bottom. 5. Pier tops should not be allowed to mushroom. The top of all piers should be formed with cardboard tubes. 6. Caving soils and groundwater were encountered in the test borings shortly after drilling or When ? I �� checked 3 days after drilling. Based on our observations, casing of the pier shafts is not expected, Wheat Ridge Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Building Division Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 6 but dewatering may be required. Concrete should be placed in the caissons immediately after drilling using "drill and pour" techniques to minimize the need for dewatering. 7. Concrete should be placed by the tremie method if more than 3 inches of water is encountered in the bottom of the pier shaft at the time of concrete placement. The tremie pipe should be lowered to the bottom of the pier shaft prior to concrete placement and should be kept below the concrete surface during concrete placement. 8. CG should observe pier drilling and construction. Alternative Basement Foundation Recommendations A spread footing foundation supported on native soils or properly compacted structural fill can be considered to support the proposed structure(s) at the basement elevation only with the entire excavation below the clay stratum and all footing elevations are at this level. Spread Footing Recommendations New foundations should be designed based on an allowable soil bearing pressure of: 3000 psf maximum and 500 psf minimum at a typical basement elevation (about 8 to 10 feet below grade). Additional spread footing foundation design and construction considerations: 1. The total and differential settlements are estimated to be approximately 1 inch or less. 2. Spread footings should have a minimum width of 16 inches for continuous footings placed on material as described above, and 24 inches for isolated pads. 3. A minimum 4 -inch void should be used below grade beams if needed to develop the minimum dead load pressure. 4. Footings placed beneath unheated areas should have at least 36 inches of covering soils to protect from frost. This depth should be verified with the local building department. 5. Lateral resistance to the spread footings is based on both friction between the footing and its subsoil and passive earth pressures of the soils on the side of the footing. An ultimate coefficient of friction of 0.35, and a passive pressure based on an equivalent fluid weight of 180 pcf for the soils is recommended. 6. The foundation system should be reinforced to span an unsupported length of 10 feet. 7. It is required that a representative of the Engineer observes the foundation excavation prior to foundation construction and/or fill placement in order to evaluate the possible fill soils. 8. The foundation excavation should be protected from runoff, and multiple wetting and drying cycles. Runoff into the foundation excavation should be avoided. City Of wheo} Pid9e Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 8ui1ain9Divsion Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 7 Foundation 'Walls Foundation walls which are laterally supported and expected to undergo a minimal amount of movement should be designed with based on a lateral "at -rest' earth pressure computed based on an equivalent fluid weight of 60 pcf if the onsite soils are used as backfill. Topsoil should not be used as backfill. The earth pressure can be reduced to 50 pcf for "active" conditions where significant wall deflection can occur, such as at site retaining walls. A passive pressure based on an equivalent fluid weight of 180 pcf for sandy, silty, clay is recommended. These pressures assume drained conditions behind the foundation walls. The buildup of water behind a foundation wall will increase the lateral pressures on the wall. All foundation walls should be designed for appropriate hydrostatic and surcharge pressures such as: adjacent buildings, traffic, construction materials and equipment. These pressures assume drained conditions behind the foundation walls. The buildup of water behind a foundation wall will increase the lateral pressures on the wall. Foundation Wall Backfill Placement: In landscape areas, foundation wall backfill should be compacted to at least 90% percent of the standard proctor maximum dry density (ASTM D 698) near the optimum moisture content (OMC). In areas of external and interior flatwork (i.e. sidewalks, driveways, garage slabs), foundation wall backfill should be compacted to at least 95% percent of the standard proctor maximum dry density (ASTM D 698) at or slightly above the optimum moisture content. Floor Slabs The onsite soils are suitable to support slab -on -ground construction, with a low (at basement level) and moderate (at existing grade level) risk of slab heave due to potentially expansive soils. Potential floor slab movement of less than 1" exists at the basement level and 2" to 3" exists on the site near the ground surface, assuming a depth of moisture variation ("depth of wetting") of about 20 feet. Structural floors over a crawlspace or minimum 12 -inch void space should be used if this potential movement is not acceptable to the owner or builder. Slab Design: To reduce the effects of differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints that allow for unrestrained vertical movement. Partitions should not be designed or constructed to bear on slabs supported on grade. A 3 -inch void should be established below or above partitions during construction and monitored and maintained by the owner after construction. The void space can be covered with a molding strip that is not attached to the partition. Joint spacing should be determined on floor thickness, nominal aggregate size, slump, and be consistent with the recognized guidelines such as the Portland Cement Association and the American Concrete Institute. Cracks and movement of the slabs supported on grade can be transmitted through rigid floor coverings. Performance expectations should be taken into consideration in the selection of floor slab coverings. City of Wheat Ridge Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Building Division Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 8 Floor Slab Subgrade: Some areas of soft and/or loose soils may be encountered in the floor slab areas. Some subgrade improvement of these materials may be required at the time of excavation as directed by the engineer. Soft or disturbed soils observed in the excavation should be compacted on grade or removed and replaced with structural fill. Any fill placed below structural areas should consist of granular, non - expansive soil compacted to at least 95% of the standard Proctor maximum dry density (ASTM D 698) near the optimum moisture content. Plastic Moisture Barrier or Gravel Layer: Based on subsurface conditions observed in the test boring(s) and our understanding of the planned construction, a plastic moisture barrier and 4 -inch gravel layer to protect a slab near the ground surface is optional for this site from a geotechnical standpoint. Applicable building codes may require these items. Interior Plumbing: All plumbing lines should be testing for leaks. Where plumbing lines enter through the slab, positive breaks should be provided. Connections to mechanical equipment should be flexible. Any new fill placed beneath floor slabs should be a non -expansive, granular material compacted to at least 95% of the standard Proctor maximum dry density near the optimum moisture content. Subsurface Drainage It is recommended that below grade, finished or usable living space be protected from surface water infiltration with a perimeter drain system. The drainage system can be either an interior or exterior type. Details of typical drainage systems are presented in Appendix B. Surface Drainage 1. The following drainage precautions should be observed and maintained at all times during and after construction: 2. Excessive wetting of the foundation excavation and sub -floor soils should be avoided. 3. Exterior backfill should be placed as recommended herein. 4. The ground should be sloped away from the building. A minimum slope of 6 inches in the first 5 to 10 feet in landscaped areas (10%) and 3 inches in 10 feet in paved areas (3%) is recommended. 5. Roof down spouts should discharge well beyond foundation wall backfill zones. 6. Plastic membranes should not be placed adjacent to the foundation walls. A pervious textile should be used to control weed growth. 7. Any settling of foundation or foundation wall backfill should be re -graded to maintain the slopes noted above. City of Wheat Ridge Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Building Division Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 9 Exterior Flatwork The subgrade soils should be scarified and compacted to at least 95% of the standard Proctor maximum dry density near the optimum moisture content in areas of driveway pavement or approach apron for a garage, if constructed. Proof -rolling of these areas is recommended. Soft and deflecting areas should be removed and replaced with properly compacted fill. Radon Radon may be a potential concern in Colorado. If a crawl space is constructed it should be well ventilated. if a gravel layer is placed beneath the floor slab it can be incorporated into a radon abatement system if this becomes necessary in the future. The local building department should be contacted for more information regarding radon issues in this area. Radon Prevention methods should conform to EPA Radon Mitigation Standards: EPA 402-R-93-078, October 1993 and revised April 1994. Mold Mold can develop in crawl spaces that become damp under certain conditions. If a crawispace is constructed, it should be well ventilated. A vapor barrier should be placed on exposed soil to help control indoor moisture levels and should be sealed at the edges and seams. A professional hygienist should be contacted to address any potential mold concerns and mitigation methods. Refer to A Brief Guide to Mold, Moisture and Your Home for additional information: EPA 402-K-02-003, dated September 2010, for more information. Crawlspace Recommendations (if needed) A health and safety professional with experience in the design of crawlspaces can be consulted to provide recommendations to reduce moisture infiltration into crawlspaces. Such recommendations may include fining the crawispace with polyethylene plastic that is sealed and mechanically attached to the foundation. Plastic should not be attached to the foundation within 6 inches of untreated wood members of the framing or flooring. Also, plastic should not be attached to metal framing members such as column posts, but can be attached to concrete foundations supporting column posts. Limitations and Exclusions This study has been conducted in accordance with generally accepted geotechnical engineering practices using the degree and care and skill ordinarily exercised by members of the same profession currently practicing under the same or similar circumstances, and for use by the client for design purposes at the named site. City of Wheat Ridge Building Division Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 Geotechnical Engineering Report Project No.: 18-075 7-23-18 Page 10 The conclusions and recommendations presented in this report are based on the data obtained from the exploratory boring(s) drilled at the approximate location presented on Figure 1, and the proposed construction. An additional discussion of the limitations of geotechnical engineering practices is presented in Appendix A. An environmental assessment (ESA Phase I or 11) of the site is outside our scope of work for this project. This report should also not be considered as an indication of the absence of or as an evaluation of any potential environmental, geologic or mining hazards for the subject site. If during construction, fill, soil or water conditions appear to be different than that presented in this report, CG should be contacted to reevaluate the recommendations presented herein as necessary. A representative of our office must observe foundation excavations, pier installation, backfill operations, and foundation bearing strata, as applicable, in order to confirm the recommendations of this report. If you have any questions regarding this report, please contact our office. Cushman Geoscience LLC Prepared by: Reviewed by: C� LtC-F� UO A 46434 ; 1 David A. Cushman, P.G., CPG Scott Barton, P.E. Engineering Geologist Project Engineer Attachments — Figures 1.0 through 3.9 Appendix A — Important Information about This Report Appendix B — Foundation Drain Details Distribution: digitally stamped PDF via email to addressee, printed copies mailed upon request References Foundations and Earth Structures, Naval Facilities Engineering Command Design Manuals 7.01 and 7.02, 09-01-1986 Guideline for Slab Performance Risk Evaluation and Residential Basement Floor System Recommendations, Colorado Association of Geotechnical Engineers, 1996. City of CAV/YMA/EMC/DAC/S D B Wheat Ridge Building Division Cushman Geoscience LLC 195 South Hoyt Street, Lakewood, Colorado 80226 nA NOTES: 1) Not to Scale 2) 19 Indicates location of exploratory test boring. I CUSHMAN GEOSCIENCE 3300 Ames St SITE PLAN City of PROJECT NO. 18-07 FIGURE NO. Buildidgbi M1 KEY QI [_.GESS (HOLOCENE AND PLEISTOCENE)—Yellowish-brown to - -- light -grayish -brown sanely silt. Upper 2-4 *Pet (03 6-1 2 m) may contain appreciable amounts of clay and silty clay. Exhibits co- lumnar structure: slightly calcareous; slightly sticky when wet. Generally less than 10 feet. (3 m) thick, but may be as much as 20-25 feet ((--7.6 m) thick in northeastern part of quadrangle SITE LOCATION SOURCE: Lindvall, R. M, 1979, Geologic map of the Arvada quadrangle, Adams, Denver, and Jefferson Counties, Colorado: U.S. Geological Survey, Geologic Quadrangle Map GQ -1453 CUSHMAN GEOSCIENCE 3300 Ames St PROJECT NO. 18-075' Geologic Map FIGURE NO. 1.1� B-1 B-2 B-3 0 41 126/12 24 121112 5 MC=12,4 mc=10.1 mc=11.9 5— v v DD=111 ..... DD=111 DD=106 -0.24, 5016.5 0.3 750/7 0.0 ..'-1 50/6 —10 MC=13.9 MC=18.3 MC=9.6 10 DD=1 18 DD=111 DD=113 —16 50/3 0.8 :]50/8 :]5015 ..... ...... MC=21.2 is DD=106 ..... 3 ..... 1.0 50/7 0.3 5016 3 > -0.2 -050/7 —20 mc=19.6mc=18.0 mc=15.8 20 ...... DD=112 DD=106 DD=1 13 —25 25- 3 3 —30 50/5 30- 35 36 LEGEND: CLAY, SILTY, SANDY TO VERY SANDY, SCATTERED GRAVEL, HARD, MOIST, BROWN GRAVEL, SILTY, CLAYEY, MOIST, BROWN SANDSTONE/CLAYSTONE BEDROCK, INTERMIXED AND INTERLAYERED, VERY HARD, MOIST, BROWN, GRAY, OLIVE INDICATES A "MODIFIED CALIFORNIA" SAMPLER WAS DRIVEN 26112 INDICATES THAT 26 BLOWS WITH A 140 -POUND HAMMER FALLING 30 INCHES WERE REQUIRED TO DRIVE A MODIFIED CALIFORNIA SAMPLER 12 INCHES INTO THE SUBSURFACE SOILS 4.1 t INDICATES AMOUNT OF VOLUME CHANGE (%) AND DIRECTION OF SAMPLE MOVEMENT ON WETTING 3 INDICATES DEPTH TO GROUNDWATER AND NUMBER OF DAYS AFTER DRILLING WAS OBSERVED 3 --> INDICATES DEPTH AT WHICH BORING CAVED AND NUMBER OF DAYS AFTER DRILLING OBSERVED MC= INDICATES MOISTURE CONTENT (%) OF SAMPLE DD= INDICATES DRY DENSITY (pct) OF SAMPLE -200= INDICATES AMOUNT OF MATERIAL PASSING NO. 200 SIEVE (%) NOTES: 1) THE BORINGS WERE DRILLED ON MAY 18, 2018 WITH 4 -INCH DIAMETER, SOLID -STEM AUGER POWERED BY A CME -45 DRILLING RIG. 2) THE LOCATIONS OF THE BORINGS WERE DETERMINED APPROXIMATELY IN THE FIELD BY TAPING OR PACING FROM FEATURES ON THE SITE PLAN AND SHOULD ONLY BE CONSIDERED ACCURATE TO THE DEGREE IMPLIED BY THE METHOD USED. 3) CHANGES BETWEEN MATERIAL TYPES ARE APPROXIMATE AND TRANSITIONS MAY BE GRADUAL. GROUNDWATER ELEVATIONS MAY VARY SEASONALLYAND FROM YEAR TO City of YEAR DEPENDING ON CLIMATE AND OTHER FACTORS. Wheal Ridge 3300 Ames St PROJECT NO. 18-075 CUSHMAN GEOSCIENCE BORING LOGS, LEGEND & NOTES IFIGURE NO. 2.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 E c -1.0 m -2.0 -3.0 -4.0 -5.0 -6.0 -7.0 -8.0 100 10000 Vertical Pressure (PSF) Sample Description: Clay, silty, sand Boring No. B-1 Moisture Content (%) 12.4 Depth (ft) 4 Dry Density,(pcf) 111 Swell % 4.1 Swell Pressure s 10,300 Yy . CUSHMAN GEOSCIENCE --- _ 3300 Ames St 1project No. -075 SWELL -CONSOLIDATION TEST IFiqure No. 3.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 E c -1.0 as -2.0 E -3.0 Cn -4.0 -5.0 -6.0 -7.0 -8.0 100 10000 Vertical Pressure (PSF) Sample Description: Sandstone Boring No. B-1 Moisture Content (%) 13.9 Depth (ft) 9 Dry Densit , (pco 118 Swell % -0.2 ur Swell Presse s N/A —City whet r( CUSHMAN GEOSCIENCE 3300 Ames St _ Project No, 18-075 SWELL -CONSOLIDATION TEST Figure No. 6.0 5.0 4.0 3.0 2.0 0 1.0 0.0Nk - o -1.0 m -2.0 eq -3.0 -4.0 -5.0 -6.0 -7.0 -8.0 100 10000 Vertical Pressure (PSF) Sample Description: Cla stone _ Ui BoringNo. B-1 Moisture Content (%) 19.5 CAW Depth (ft) 19 Dry Densit , (pco 112 Swell % 1.0 Swell Pressure sf) 3,200 CUSHMAN GEOSCIENCE 3300 Ames St Project No, 13-075 SWELL-CONSOLIDATION TEST Figure No. 3.2 8.0 7.0 6.0 5.0 4.0 3.0 -2.0 -3.0 -4.0 -5.0 -6.0 � I I I I I 11H I I I 1 11111 1 1 _.-L-1 1 1 111 100 Sample Description Boring No. Depth (ft) 10000 Vertical Pressure (PSF) Clay, v. sandy, sil B-2 Moisture Content 4 _ Dry Densit - (pco Swell (%) Swell Pressure (c CUSHMAN GEOSCIENCE 1 3300 Ames St I SWELL -CONSOLIDATION TEST 10.1 cal. 2.0 E Whecrt > 1.0 0 Iding D; Project No, M Figure No. 3.3 0.0 E m -1.0 co -2.0 -3.0 -4.0 -5.0 -6.0 � I I I I I 11H I I I 1 11111 1 1 _.-L-1 1 1 111 100 Sample Description Boring No. Depth (ft) 10000 Vertical Pressure (PSF) Clay, v. sandy, sil B-2 Moisture Content 4 _ Dry Densit - (pco Swell (%) Swell Pressure (c CUSHMAN GEOSCIENCE 1 3300 Ames St I SWELL -CONSOLIDATION TEST 10.1 cal. ill - Whecrt 2.4 4,700 Iding D; Project No, 18-075 Figure No. 3.3 8.0 7.0 6.0 5.0 4.0 0 3.0 aCi 2.0 E 0 1.0 cv 0.0 -1.0 -2.0 -3.0 -4.0 -5.0 -6.0 100 Sample Description Boring No. Depth (ft) 10000 Vertical Pressure (PSF) Sandstone, claystone B-2 Moisture Content 9 Dry Density c Swell Swell Pressure (psf) 18.3 city of 1 1 1 Wheat Rig 0.3 2,400 uilding M% CUSHMAN GEOSCIENCE 1 3300 Ames St jProject No. 18-075 SWELL -CONSOLIDATION TEST IFigure No. 3.4 8.0 7.0 6.0 5.0 4.0 A. 0 3.0 2.0 c 1.0 a� 0.0 a -1.0 -2.0 -3.0 -4.0 -5.0 -6.0 100 10000 Vertical Pressure (PSF) or Sample Description: Cla stone, sandstone city Boring No. B-2 Moisture Content°lo} 21.2 Depth (ft) 14 Dry Density c 1106 'ot Rids:` Swell % 0.H IC'j I(1g Div Swell Pressure sf) 4,700 i= CUSHMAN GEOSCIENCE3300 _ Ames St Project No. 18-075 E SWELL-CONSOLIDATION TEST iFigure No. 3.5 8.0 7.0 6.0 5.0 4.0 0 3.0 V' �J W 2.0 E 0 1.0 m CD 0.0 -1.0 -2.0 -3.0 — -4.0 -5.0 �- -6.0 100 10000 Vertical Pressure (PSF) Sample Description: Cla stone Boring No. B-2 Moisture Content (%) 18.0 W, Depth ft 19 Dry Densit c 106 Swell % 0.3 auiraf,,f, Swell Pressure sf) 1,400 e 3300 Ames St Project No, 18-075 CUSHMAN GEOSCIENCE SWELL -CONSOLIDATION TEST Figure No. 3.6 8.0 7.0 6.0 5.0 4.0 3.0 2.0 E 0 1.0 0.0 - -1.0 -2.0 -3.0 -4.0 -5.0 -6.0 100 10000 Vertical Pressure (PSF) Sample Description: _ Clay, silty, sl. sandy to v. sandy Boring No. B-3 Moisture Content (%) _ 11.9 Depth ft 4 Dry Density c 106 Swell % 1.8 Swell Pressure (psf) 2,700 CUSHMAN GE OSCIENCE 3300 Ames St I Project No SWELL -CONSOLIDATION TEST IFiclure No. wE,ecat k uildin•n ,.. 18-075 3.7 8.0 7.0 6.0 5.0 4.0 0 3.0 2.0 E c 1.0 ca 0.0 E -1.0 -2.0 -3.0 -4.0 i -5.0 -6.0 100 10000 Vertical Pressure (PSF) Sample Description: Sandstone, cla stone Boring No. B-3 Moisture Content (%} 9.6 Depth (ft) 9 Dry Density c 113 Swell % 0.0 Swell Pressure (psf) N/A CUSHMAN GEOSCIENCE 3300 Ames St IProject No. 18-075 SWELL-CONSOLIDATION TEST I Figure No. 3.8 cion 8.0 7.0 6.0 5.0 4.0 3.0 w 2.0 E 0 1.0 a� 0.0 s� -1.0 -2.0 -3.0 -4.0 -5.0 -6.0 100 10000 Vertical Pressure (PSF) Sample Description: Sandstone, claystone Boring No. B-3 Moisture Content (%) 15.8 cia' Depth (ft) 19 Dry Density c 113 wheca Swell % -0.2 Swell Pressure sf) N/A ciuildin ; 3300 Ames St Project No. 18-075 CUSHMAN GEOSCIENCE SWELL-CONSOLIDATION TEST IFigure No. 3.9 cion Appendix A Important Information about this Report The data collected by Cushman Geoscience LLC (CG) during this geotechnical exploration was used to provide geotechnical information and recommendations based on subsurface conditions for the site evaluated, the potential effects of those conditions on the proposed structure, and recommended foundation type for the proposed structure. The stratification lines shown on the boring log(s) are approximate and actual transitions between materials may be more gradual or more rapid than indicated on the boring log(s). Actual subsurface conditions encountered during construction may differ from the subsurface conditions presented herein. This uncertainty can not be eliminated due the variable nature of geologic conditions. Material characteristics and engineering properties of soil and bedrock may vary between samples and between borings. The actual material characteristics and engineering properties of the soil or bedrock may differ from interpretations based on sampled soil and bedrock. Quantitative conclusions prior to construction regarding the geotechnical performance of a structure are not possible due to the potential variability of subsurface conditions. Engineering judgment and experience are used to evaluate the most likely geotechnical performance of the structure and provide geotechnical recommendations for the structure. There are no guaranties or warranties implied or expressed. The owner and client must understand that uncertainties are associated with geotechnical engineering and must determine the level of risk they are willing to accept for the proposed construction. The level of risk can be reduced, but not eliminated by more extensive exploration and sampling of the site and additional laboratory testing, which would cost more money and take more time. To reduce the level of uncertainty, the report should only be used by the referenced client for the referenced project and the construction described in the report unless authorized in writing by CG. CG should be consulted to review changes to the proposed construction such as the nature, size, configuration, orientation, location or weight of proposed improvements. Additionally, the practice of geotechnical engineering is continually developing knowledge and experience, and it must be understood that recommendations are based on the state of the practice at the location and time the report was prepared. The report should not be used more than three years after issuance unless reviewed and revised if needed by CG. The geotechnical engineering practice in the Colorado Front Range area uses a relative classification to evaluate the expansive potential of soils and bedrock. The expansive potential is categorized as low, medium, high or very high based on the swell potential. The following table presents the relative classifications. Table No.1 - Risk Categories Slab Performance Risk Category Representative Percent Swell (500 psf Surcharge) Representative Percent Swell (1000 psf Surcharge) Low 0 to< 3 0 to< 2 Moderate 3 to < 5 2 to < 4 High 5to<8 4to<6 Very High 1 8 or greater I or greater Source: Colorado Association of Geotechnical Engineers, "Guideline for Slab PerformanceRisk Evaluation and Residential Basement Floor System Recommendations (Denver Metropolitan. rea), December 1996 Wheat Ridge Building Division The slab performance generally associated with the slab performance risk categories are as follows: Appendix A Important Information about this Report Page 2 Low slab cracking, differential movement and heave Moderate slab cracking, differential movement and heave, partial framing void and furnace plenum closure High to Very High large slab cracking, differential movement and heave, closed framing void and furnace plenum Note: More or less damage can occur in any risk category due to the variable nature of soil and bedrock. It is important to note that measured swell or expansion is not the only criteria used in developing foundation and floor recommendations. Other factors considered in the development of foundation and floor recommendations are: a. Soil and bedrock variability, b. Stratigraphy, c. Groundwater depth during field activities and potential groundwater depth after construction, d. Surface water features and site drainage, e. Post construction landscaping and irrigation conditions, f. Construction details and proposed use, and g. Local experience. Landscaping of the site following construction and owner maintenance will greatly affect the performance of structures on sites with expansive soil or bedrock. Typically, moisture contents of subsurface soils and bedrock increase after construction due to surface irrigation and the cut off of evaporation that occurs when a slab or building is constructed. Poor owner maintenance, such as ground surfaces sloping towards foundations or slabs and irrigated landscaping adjacent to buildings, will increase the potential for slab and foundation movement by increasing the potential for moisture content changes in the subsurface soils. The property owner or buyer, and anyone he or she plans to sell the house to, must understand the risks associated with construction in areas with expansive soils and must assume the responsibility for maintenance of the structure and the site. The owner and prospective purchasers should review "A Guide to Swelling Soils for Colorado Homebuyers and Homeowners," a special publication (SP43) of the Colorado Geological Survey, which helps homebuyers and homeowner understand and take measures to reduce the potential for damage due to expansive soils. City or Wheat Ridge ii"Cling Bivisi" TRENCH SHOULD NOT BE DUG BELOW AN IMAGINARY PLANE EXTENDING FROM THE BOTTOM OF THE FOOTING AT A 45° ANGLE FRAMED WALL GROUND FLOOR SUPPORT REINFORCING STEEL NOTE: FLOOR SUPPORT, FRAMING AND STEEL REINFORCING SHOULD BE DESIGNED BY OTHERS UNDERSLAB FILL (SEE REPORT FOR MOISTURE -CONDITIONING AND COMPACTION OR GRAVEL SUB -SLAB DRAIN RECOMMENDATIONS) BASEMENT FLOOR SUPPORT (SEE REPORT FOR BASEMENT FLOOR RECOMMENDATIONS) /x lti tif•l '* ti• F '' •" A E OE E4C4VATIQbl rrrrrr - * TRENCH SHOULD BE AT LEAST 8 INCHES WIDE r R. AND AT HIGH POINT '12 INCHES BELOW TOP OF SLAB OR BOTTOM Of: GRADE BEAM IF /// STRUCTURAL FLOOR IS USED. TRENCH SHOULD SLOPE DOWNWARD 1/8 INCH OR MORE PER FOOT FROM HIGH POINT TO A SUMP PIT OR OUTFALL.TRENCH SHOULD BE FILLED WITH RELATIVELY CL.EAN,GRAVEL WITH 100% FROM THE VERTICAL PASSING THE 1 1/2 INCH SIEVE, 10% OR LESS PASSING THE NO. 4 SIEVE AND 3% OR LESS PASSING THE NO. 200 SIEVE. GRAVEL SHOULD >' BE COVERED WITH NON -WOVEN GEOTEXTILE FABRIC OR ROOFING FELT. r x n r k ✓ ror r i - PIPE SHOULD BE NOMINAL 4 -INCH DIAMETER AND CONSIST OF PERFORATED SCHEDULE 4 OR FLEXIBLE DRAIN TILE. TRENCHES IN SILTY SANDS AND NOT TO SCALE r GRAVELS SHOULD BE LINED WITH NON -WOVEN GEOTEXTILE FABRIC. v Cushman Geoscience INTERIOR DRAIN DETAIL - FOOTING FOUNDATION City Wheat I 81jildinq Figure No. Ftca. Int. FOUNDATION WALL BACKFILL (SEE MINIMUM SLOPER ' OF GROUND SURFACE) .y< (SEE REPORT FOR FOOTING DESIGN, REINFORCING AND CONSTRUCTION RECOMMENDATIONS) • • . 4 < TRENCH SHOULD NOT BE DUG BELOW AN IMAGINARY PLANE EXTENDING FROM THE BOTTOM OF THE FOOTING AT A 45° ANGLE FRAMED WALL GROUND FLOOR SUPPORT REINFORCING STEEL NOTE: FLOOR SUPPORT, FRAMING AND STEEL REINFORCING SHOULD BE DESIGNED BY OTHERS UNDERSLAB FILL (SEE REPORT FOR MOISTURE -CONDITIONING AND COMPACTION OR GRAVEL SUB -SLAB DRAIN RECOMMENDATIONS) BASEMENT FLOOR SUPPORT (SEE REPORT FOR BASEMENT FLOOR RECOMMENDATIONS) /x lti tif•l '* ti• F '' •" A E OE E4C4VATIQbl rrrrrr - * TRENCH SHOULD BE AT LEAST 8 INCHES WIDE r R. AND AT HIGH POINT '12 INCHES BELOW TOP OF SLAB OR BOTTOM Of: GRADE BEAM IF /// STRUCTURAL FLOOR IS USED. TRENCH SHOULD SLOPE DOWNWARD 1/8 INCH OR MORE PER FOOT FROM HIGH POINT TO A SUMP PIT OR OUTFALL.TRENCH SHOULD BE FILLED WITH RELATIVELY CL.EAN,GRAVEL WITH 100% FROM THE VERTICAL PASSING THE 1 1/2 INCH SIEVE, 10% OR LESS PASSING THE NO. 4 SIEVE AND 3% OR LESS PASSING THE NO. 200 SIEVE. GRAVEL SHOULD >' BE COVERED WITH NON -WOVEN GEOTEXTILE FABRIC OR ROOFING FELT. r x n r k ✓ ror r i - PIPE SHOULD BE NOMINAL 4 -INCH DIAMETER AND CONSIST OF PERFORATED SCHEDULE 4 OR FLEXIBLE DRAIN TILE. TRENCHES IN SILTY SANDS AND NOT TO SCALE r GRAVELS SHOULD BE LINED WITH NON -WOVEN GEOTEXTILE FABRIC. v Cushman Geoscience INTERIOR DRAIN DETAIL - FOOTING FOUNDATION City Wheat I 81jildinq Figure No. Ftca. Int. FRAMED WALL GROUND FLOOR SUPPORT REINFORCING STEEL NOTE: FLOOR SUPPORT, FRAMING AND STEEL REINFORCING SHOULD BE DESIGNED BY OTHERS BASEMENT FLOOR SUPPORT TRENCH SHOULD BE AT LEAST 8 ` INCHES WIDE AND AT HIGH POINT 12 INCHES BELOW TOP OF SLAB OR BOTTOM OF GRADE BEAM IF STRUCTURAL FLOOR IS USED. TRENCH SHOULD SLOPE DOWNWARD 1/8 INCH OR MORE PER FOOT FROM HIGH POINT TO A SUMP PIT OR OUTFALL.TRENCH SHOULD BE FILLED WITH RELATIVELY CLEAN,GRAVEL WITH 100% PASSING THE 1 1/2 INCH SIEVE, 10%ORLESS PASSING THE NO. 4 SIEVE AND 3% OR LESS PASSING THE NO. 200 SIEVE. GRAVEL SHOULD BE COVERED WITH NON -WOVEN GEOTEXTILE FABRIC OR ROOFING FELT. I I PIPE SHOULD BE NOMINAL 4 -INCH DIAMETER AND CONSIST OF PERFORATED SCHEDULE 40 OR FLEXIBLE DRAIN TILE. UNDERSLAB FILL (SEE REPORT FOR MOISTURE - CONDITIONING AND COMPACTION OR GRAVEL SUB -SLAB DRAIN RECOMMENDATIONS) TRENCH SHOULD NOT BE DUG BELOW AN IMAGINARY PLANE EXTENDING FROM THE BOTTOM OF THE FOOTING AT A 45° ANGLE FROM THE VERTICAL. NOT TO SCALE City 4 f Whe❑t R Building D isia Cushman Geoscience EXTERIOR DRAIN DETAIL - FOOTING FOUNDATION Figure No. Fta. Ext. 11 L C .�ti fti f fti EEO �.tiftifyfti , y (SEE REPORT FOR PIER DESIGN, I REINFORCING AND TRENCH SHOULD BE AT LEAST 8 INCHES WIDE AND AT FRAMED WALL GROUND FLOOR SUPPORT REINFORCING STEEL NOTE: FLOOR SUPPORT, FRAMING AND STEEL REINFORCING SHOULD BE DESIGNED BY OTHERS UNDERSLAB FILL (SEE REPORT FOR MOISTURE -CONDITIONING AND COMPACTION OR GRAVEL SUB -SLAB DRAIN RECOMMENDATIONS) BASEMENT FLOOR SUPPORT (SEE REPORT FOR BASEMENT FLOOR RECOMMENDATIONS) SLAB -ON -GRADE .�ti fti f fti �.tiftifyfti , y �1 fti . f TRENCH SHOULD BE AT LEAST 8 INCHES WIDE AND AT HIGH POINT 12 INCHES BELOW TOP OF SLAB OR BOTTOM OF GRADE BEAM IF STRUCTURAL FLOOR IS USED. TRENCH SHOULD SLOPE DOWNWARD 1/8 INCH OR MORE PER FOOT FROM HIGH POINT TO A SUMP PIT OR OUTFALL.TRENCH SHOULD BE FILLED WITH RELATIVELY CLEAN,GRAVEL WITH 100% PASSING THE 1 1/2 INCH <:< SIEVE, 10% ORLESS PASSING THE NO, 4 SIEVE AND 3% OR LESS PASSING THE NO. 200 SIEVE. GRAVEL SHOULD BE COVERED WITH NON -WOVEN GEOTEXTILE FABRIC OR ROOFING FELT. ; PIPE SHOULD BE NOMINAL 4 -INCH DIAMETER AND CONSIST OF PERFORATED SCHEDULE 40 OR FLEXIBLE DRAIN TILE. City of Cushman Geoscience INTERIOR DRAIN DETAIL - PIER FOUNDATION Fiqure No. Pier Int. FRAMED WALL PIPE SHOULD BE NOMINAL 4 -INCH DIAMETER GROUND FLOOR SUPPORT AND CONSIST OF PERFORATED SCHEDULE - REINFORCING STEEL FOUNDATION ' WALL BACKFILL (SEE MINIMUM SLOPER TRENCHES SHOULD BE LINED WITH 10 -MIL NOTE: FLOOR SUPPORT, . OF GROUND (SEE REPORT FOR FRAMING AND STEEL SURFACE) WATERPROOFING IS APPLIED. REINFORCING SHOULD t> s yi, l s> BE DESIGNED BY OTHERS r> 'c=: ttc }< ^ RECOMMENDATIONS) BASEMENT FLOOR SUPPORT L VOID FORM UNDER (SEE REPORT FOR BASEMENT GRADE BEAM (SEE FLOOR RECOMMENDATIONS) REPORT FOR ----- RECOMMENDATIONS) SLAB -ON -GRADE 'tir rtirtir TRENCH SHOULD BE AT LEAST 8 INCHES { ti...tid.,. ;:; -E-�_ V I�� I WIDE AND AT HIGH POINT 12 INCHES r r•r•r.r• BELOW TOP OF SLAB OR BOTTOM ® UNDERSLAB FILL (SEE GRADE BEAM IF STRUCTURAL FLOOR IS REPORT FOR MOISTURE - USED. TRENCH SHOULD SLOPE CONDITIONING AND DOWNWARD 1/8 INCH OR MORE PER `': COMPACTION OR GRAVEL FOOT FROM HIGH POINT TO A SUMP PIT SUB -SLAB DRAIN OR OUTFAI_L.TRENCH SHOULD BE FILLED RECOMMENDATIONS) WITH RELATIVELY CLEAN,GRAVEL WITH 100% PASSING THE 1 1/2 INCH SIEVE, 10% ORLESS PASSING THE NO, 4 SIEVE AND 3% OR LESS PASSING THE NO. 200 SIEVE. GRAVEL SHOULD BE COVERED {` , :y = WITH NON -WOVEN GEOTEXTILE FABRIC r l OR ROOFING FELT. PIPE SHOULD BE NOMINAL 4 -INCH DIAMETER AND CONSIST OF PERFORATED SCHEDULE 40 OR FLEXIBLE DRAIN TILE. ^r TRENCHES SHOULD BE LINED WITH 10 -MIL PLASTIC SHEATING THAT IS MECHANICALLY (SEE REPORT FOR ATTACHED TO THE FOUNDATION WALL AFTER PIER DESIGN, WATERPROOFING IS APPLIED. REIFORCING AND CONSTRUCTION SCALE y NOT ' RECOMMENDATIONS) }TO 1 Cushman Geoscience EXTERIOR DRAIN DETAIL - PIER FOUNDATION { City o r' Wheat Ri e buildina F ;t on re No. Pier Ext. City of Wheat R.Jidge Date: .Tune 6, 2019 Location: 3300 Ames Street ATTENTION: BUILDING DIVISION SINGLE LAWL Y/DUPLEX BUILDING PERS jT,4PPLIC'ATIO.,?V REVIEW I have reviewed the submitted application documents to construct a New Home - Single Family - Duplex located at the above referenced address. Please note the comments checked below. 1. ✓ Drainage: a. Drainage Letter & Plan required: —Yes ✓ No b. Site drainage/grading plan have been reviewed and are: ✓ OK NOT O ;refer to 2_ ✓ Public Improvements required & to be completed with project: stipulations. a. street paving/patching: ✓ Yes b. curb & gutter: V Yes No c. sidewalk -Yes -- NO Completed V/ Yes d. Other (specify):`Yes No r) Complete Completed For items not constructed, the amount of funds taken in lieu of construction: $ 3. . ✓.__ Does all existing roadway/alley R.O.W. meet the standards of the City: ✓ Yes If not, what is required? If R.O.W. is required, has the deed been received: No Yes ____ No (see Note below) NOTE: All deeds must be reviewed and approved prior to issuance of the Certificate of Occupancy. 4. ✓ APPROVED: The Public Works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated requirements and/or attached stipulations. Signature Date A2/1_q__ 5. N/A NOT APPROVED: The Public Works Department has reviewed the submitted material and does not approve this Permit Application for the stated reason(s)'— Signature David F. Brossman, P.L.S. Date 5. ✓ Stipulations: Direct roof drain downspouts to protect adjacent properties from stormwater runoff. 7. ✓ A Drainage Certification Letter accompanied by As -Built plans from the Engineer -of -Record shall be required prior to the issuance of the Certificate of Occupancy. 8. 1I NOTE: ANY DAMAGE TO EXISTING PUBLIC IMPROVEMENTTS AS A RESULT OF PROJECT CONSTRUCTION SHALL BE REPAIRED PER ROW CONSTRUCTION PERMIT PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. Rev 06103 3 City of ` h6atRge City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, Co 80033-8001 P: 303,235.2861 F: 303.235.2857 NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATED: June 6, 2019 ADDRESS: 3300 Ames Street Dear Contractor: In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as determined by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the existing condition(s) of the public improvements at this address. If you have any questions, please contact me at 303.235.2864 Sincerely, David F. Brossman, P.L.S. Development Review Engineer CC: File Rev 2108 LCity of w�iC�ae City of Wheat Ridge Municipal Building 7540 W. 29' Ave. Wheat Ridge, CO 86033-8001 P: 303.235.2861 F: 303.235.2857 PUBLIC WORKS DEVELOPMENT REVIEW FEES Date: June 69 2019 Location of Construction: 3300 Ames Street Purpose of Construction: Single Family ✓ New Home - Single Family - Duplex Commercial Developownt Review Processing Fee: ................................................ $100.00 (Required of all projects for document processing) Multi -Family — __— $ 100.00 Sinele Family ResidencelDunlex Review Fee:... .................................. $50.00 $ 50.00 Commercial/Muld-Famil- Review Fees: (Fees include reviews of the In and 21 submittals) • Review of existing or minimal technical documents: ........................ $200.00 $ • Initial review' of technical civil engineering documents: 5600.00 $ • Traffic Impact Study Review Fee : ............................................. ....... $600.00 $ • Trip Generation Study Review Fee: ................................ ................. $200.00 $ • Stormwater Management Plan (SW -MP) Review Fee: ....................... $200.00 $ • O & M Schedule Review & SMA Recording Fee ............................. $100.00 $ • Construction Control Plan................................................................. $100.00 $ ' Each Application will be reviewed by staff once and returned for changes_ If after review of the second submittal changes requested by staff have not been fully made to the civillsttr mwater/trafrre dooumeats, further reviews will be subject to the following Resubmittal Fees: • Resubmittal Fees: 3rd submittal ('/x initial review fee): .................................................... $300.00 g 4th submittal (full initial review fee)........ .......................................... $600.00 $ Allsubsequent submittals: ................................................................. $600.00 X = $ (Full initial review fee) TOTAL REVIEW FEES (due at time of Building Permit issuance): :SFL1 SO.00 PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE LICENSING AND PERMITTING FEES REQUIRED TO CONSTRUCT IMPROVEMENTS AND UTILITIES WITHIN THE PUBLIC RIGHT-OF-WAY. Rev 05119 Static Pressure and Friction Rate Job: 3300 Ames St Date: 05/22/2019 Entire House� By. Dakota Groves Ultimate Heating &Cooling � � � � 0 0 I 4971 Monaw St., Commerce City, CO 80022 Project Information For: Feaster Realty 3300 Ames Street, Wheatridge, CO 80212 Available Static Pressure Total Effective Length Heating Cooling (in H2O) (in H2O) External static pressure 0.90 0.90 Pressure losses 42 26 Coil 0.21 0.21 Heat exchanger 0 0 Supply diffusers 0.02 0.02 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.54 0.54 Total Effective Length Supply Ducts Return Ducts Friction Rate Heating (in/100ft) 0.061 OK 0.061 OK Cooling (in/100ft) 0.061 OK 0.061 OK Fitting Equivalent LengthDetails Supply 8A7=30, 4G=80, 8A7=30, 8A7=30, 2A2=55, 12H1=20, 8E=10, 1 F1=120: TotalEL=375 Return 6G=30, 8A7=30, 8A7=30, 6C6=115, 6CB=25, 6CA=10, 6CA=10, 8D1=80, 5N=55, 6CA=10: Total EL=395 wrilghtsoft, H Comfort BulderbyWrigFdsoft18.0.32RSU27046 "MilkSt D�lexes\3300 Ames Sl (South Bldg Right).r p Calc= MJ8 Front Door faces: W Ow oS w %Gd,9 9P 14:33:21 Page 1 Supply Return (ft) (ft) Measured length of run -out 30 17 Measured length of trunk 42 26 Equivalent length of fittings 375 395 Total length 447 438 Total effective length 885 Supply Ducts Return Ducts Friction Rate Heating (in/100ft) 0.061 OK 0.061 OK Cooling (in/100ft) 0.061 OK 0.061 OK Fitting Equivalent LengthDetails Supply 8A7=30, 4G=80, 8A7=30, 8A7=30, 2A2=55, 12H1=20, 8E=10, 1 F1=120: TotalEL=375 Return 6G=30, 8A7=30, 8A7=30, 6C6=115, 6CB=25, 6CA=10, 6CA=10, 8D1=80, 5N=55, 6CA=10: Total EL=395 wrilghtsoft, H Comfort BulderbyWrigFdsoft18.0.32RSU27046 "MilkSt D�lexes\3300 Ames Sl (South Bldg Right).r p Calc= MJ8 Front Door faces: W Ow oS w %Gd,9 9P 14:33:21 Page 1 Name Trunk Htg Clg Design Veloc Diam H x W Duct Stud/Joist Opening (in) Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2A PeakAVF 427 491 0.061 737 13.9 8 x 12 ShtMetl st2 st2 PeakAVF 804 857 0.061 772 13.9 8 x 20 ShtMetl 168 st1 PeakAVF 431 378 0.071 646 10.8 8 x 12 ShtMetl Ox 0 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat] Trunk rb4 Ox 0 194 157 108.3 0.247 556 8.0 Ox 0 ShMt rt1 rb6 Ox 0 212 122 282.5 0.095 609 8.0 Ox 0 ShMt rt1 rb5 Ox 0 157 168 166.0 0.161 480 8.0 Ox 0 ShMt rb7 Ox 0 171 232 437.8 0.061 666 8.0 Ox 0 ShMt rt1 rb2 Ox 0 182 213 309.8 0.086 611 8.0 Ox 0 ShMt rt1 rb1 Ox 0 161 184 231.3 0.116 527 8.0 Ox 0 ShMt rt1 rb3 Ox 0 158 159 171.8 0.156 593 7.0 Ox 0 ShMt rt1 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 1078 1067 0.061 647 15.6 10 x 24 ShtMetl . W r1E,, htsoft, 2019 -May -22 14:33:21 Comfort Bulder by W rightsoft 18.0.32 RSU27046 Page 2 P1�✓4�i1 ...St DLrpIexes\3300 Ames St (Souh Bldg RigIR).r p Calc= MJ8 Frort Door faces: W Duct System Summary Entire House Ultimate Heating & Cooling 4971 Monaco St, Commerce City, CO 80022 Project Information For: Feaster Realty 3300 Ames Street, Wheatridge, CO 80212 885 ft Supply Branch Detail Table Job: 3300 Ames St Date: 05/22/2019 By: Dakota Groves Cooling Heating External static pressure 0.90 in H2O Pressure losses 0.36 in H2O Available static pressure 0.54 in H2O Supply/ return available pressure 0.273 / 0.267 in H2O Lowest friction rate 0.061 in/100ft Actual airflow 1235 cfi-n Total effective length (TEL) st1 Bed 885 ft Supply Branch Detail Table Job: 3300 Ames St Date: 05/22/2019 By: Dakota Groves Cooling 0.90 in H2O 0.36 in H2O 0.54 in H2O 0.273 / 0.267 in H2O 0.061 i n/100ft 1235 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath h 628 30 16 0.079 5.0 0x0 ShMt 20.8 325.0 st1 Bed c 1289 78 84 0.071 6.0 Ox 0 ShMt 38.8 345.0 st1 Bed 2 h 1918 93 69 0.065 7.0 Ox 0 ShMt 50.3 370.0 st2 Bed -A c 1289 78 84 0.082 6.0 Ox 0 ShMt 28.0 305.0 SO Dlring h 2010 97 79 0.107 6.0 Ox 0 ShMt 19.3 235.0 st1 Diring-A h 2010 97 79 0.094 6.0 Ox 0 ShMt 20.0 270.0 st1 Fut Bath h 173 8 0 0.079 4.0 Ox 0 ShMt 35.3 310.0 st2A Fut Room 1 h 1028 50 36 0.091 5.0 Ox 0 ShMt 18.3 280.0 SO Fut Room 2 h 907 44 36 0.076 5.0 Ox 0 ShMt 47.0 310.0 st2A Kitchen c 1192 70 78 0.092 5.0 Ox 0 ShMt 21.0 275.0 st2 Living c 1639 91 107 0.079 7.0 Ox 0 ShMt 49.0 295.0 St2A Living -A c 1639 91 107 0.093 7.0 Ox 0 ShMt 39.3 255.0 st2 Living -B c 1639 91 107 0.088 6.0 Ox 0 ShMt 46.3 265.0 st2A M Bath h 1393 67 27 0.074 6.0 Ox 0 ShMt 64.8 305.0 st2 M Bed c 1786 85 116 0.061 7.0 Ox 0 ShMt 71.8 375.0 st2A M Bed -A c 1786 85 116 0.069 7.0 Ox 0 ShMt 62.3 335.0 st2A TC h 462 22 9 0.063 4.0 Ox 0 ShMt 69.8 360.0 st2A UrffBSmt c 1322 56 86 0.091 6.0 Ox 0 ShMt 30.0 270.0 st2 City of Wheat Ridge 111101110111119 DIM0117- wrightsoft¢ 2019 -May -2214:33:21 Comfort Builder by Wrightsoft 18.0.32 RSU27046 Page 1 ✓Vri ...St Duplexes\3300 Ames St (South Bldg Right).rup Calc= MJ8 Front Door faces: W BSMT 6-1 7" 7" I T 12x8 Fut Bath c4" 7"� F -HI Rae 4" 6" 8 " 7 8" 8n 7" Utif Bsmt Adj Bldg 6" Stair 24x10 20x8 7,. 5" � 8" 8" 8" 5" -1111 5" 6' 6" 12x8 6" 6" Job #: 3300 Ames St. Performed by Dakota Groves for: Feaster Realty 3300Ames Street W heatridge, CO 80212 Ultimate Heating & Cooling 4971 Monaco St. Commerce City, CO 80022 Scale:1 :75 Page 3 Comfort Builder by W rightsoft 18.0.32 RSU27046 2019 -May -22 14:33:31 0Ames R (Souk Bldg Rght).W Entry Level 7„ 711 wl-' I iitche l 611 7" EE 7" 711-114 6" —* Job #: 3300 Ames St. Performed by Dakota Groves for: Feaster Realty 3300Ames Street W heatridge, CO 80212 Ultimate Heating & Cooling 4971 Monaco St. Commerce City, CO 80022 l OV, u is �rQOl��d� ayot� Scale:1 :75 Page 2 Comfort Builder by W rightsoft 18.0.32 RSU27046 2019-May2214:33:31 ...OAmes a (South Bldg Rght).rup N Second Story r 71' 7" M Bed 7TC 471 811 M Bath Laundry M CIO Adj Bldg Stair 2 Hall Bed 2 7t1—A 8" 8" Bed Bath 1 611 611 1 Job #: 3300 Ames St. Ultimate Heating & Cooling Scale: 1 : 75 Performed by Dakota Groves for: Page 1 Feaster Realty 4971 Monaco St. Comfort Builder by W thtsoft 3300AmesStreet Commerce City, CO 80022 18.0.32 RSU27046 W heatridge, CO 80212 2019 -May 22 14:33:31 ...OAmes a (Sour Bldg Rght).rup Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves 1 Room name Stair2 Hall 2 Exposed wall O ft O ft 3 Room height 10.0 It heat/cool 10.0 it heat/cool 4 Room dimensions 4.0 x 12.3 ft 1.0 x 117.8 ft 5 Room area 49.0 T 117.8 it' Ty Construction Ll -value Or HTM Area Area(ft) ) Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) orperimeter (ft) (Btuh) HTt7 Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basementwall, light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, vd ext, 0.060 e 4.36 1.11 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 D Door, wd sctype 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basement wall, light 0.065 s 1.20 0.00 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 2336 1525 0 0 0 0 0 0 0 0 2glazing, dr outr, 0.320 s 23.36 1525 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 s 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, or outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 G 2 glazing, or outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, droutr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 qlazinq, dr outr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W Basementwall, light 0.065 w 1.78 0.00' 0 0 0 0 0 0 0 0' W Frame wall, wd ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 D Door, wd sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Attic calling, aspha 0-021 1.50 0.97 49 49 74 47 118 118 177 114 F Below grade floor,) 0.007 0.54 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -9 -22 Envelope loss/gain 74 38 177 92 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 74 38 177 92 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -74 -38 -177 -92 14 Subtotal 0 0 15 Duct loads -0% 0% 0 0 -0% 0% Jy 0 0 Total room load 00 0 Air required (dm) ) 0 0 �P• 0 rACCA to meet all requirements Ed. PA `ti'e i'� 2019 -May -2214:33:20 Comfort B Dlder bAZZ,Ky Wrigtdsoft 18.0.32 RSU27046 Page 11 St Duplexes\3300 Ames St (South Bldg RigM).np Calc = MJ8 Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By: Dakota Groves 1 Room name MCIo Laundry 2 Exposed wall O ft O ft 3 Room height 10.0 ft heat/000l 10.0 ft heaV000l 4 Room dimensions 5.5 x 10.3 It 4.0 x 6.8 ft 5 Room area 56.4 fV 27.0 ft Ty Construction U -value Or HTM Area (ft) Load Area (ft) Load number (Btuh/Fe--°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basement wall, light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, vd ext, 0.060 e 4.36 1.11 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, or outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11 G 2 glazing, or outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 Door, wd sctype 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basementvall, light 0.065 s 1.20 0.00 0 0 0 0 0 0 0 0 L�--G 2 glazing, droutr, 0.320 s 23.36 15.25 0 0 0 0 0 0 0 0 LG 2 glazing, droutr, 0.320 s 23.36 1525 0 0 0 0 0 0 0 0 W Frame wall, M ext, 0.060 s 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, droutr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazing, or outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, or outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2glazinq,droutr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W Basementwall,light 0.065 w 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, M ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 t2 G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 Door, M sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Atfic ceiling, aspha 0.021 1.50 0.97 56 56 85 55 27 27 41 26 F Belowgrade floor, 1 0.007 0.54 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -11 -102 Envelope lossigain 85 44 41 -76 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 00 0 Applianoes/other 0 500 Subtotal (lines 6 to 13) 85 44 41 424 Less edemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution -85 -44 -41 -424 14 Subtotal 0 0 0 0 15 Dudloads -0% 0% 0 0 -0% 0% 0 0 ITTotal room load 0 0 0 0 Air required (dm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �r wrigtstffiaft 2019 -May -2214:33:20 ComfortBulder by W rightsoft 18.0.32 RSU27D46 Page 10 StDiplexes\3300Ames St (South Bldg Right).np Calc =MJ8 Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St, Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By: Dakota Groves 1 Room name TC M Bed 2 Exposed wall 4.3 ft 25.3 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 6.5 x 4.3 It 1.0 x 227.9 ft 5 Room area 2Z6 fF 227.9 fl? Ty Construction Ll -value Or HTM Area (ftp) Load Area (ft=) Load number (Btuh/F--°F) (BtuhtW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basement wall, light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 e 4.36 1.11 0 0 0 0 198 139 604 154 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 5 0 117 172 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 54 0 1261 1860 11 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 D Door, wd sctype 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basementwall, light 0.065 s 1.20 0.00 0 0 0 0 0 0 0 0 [-::: 2 glazing, droutr, 0 320 s 23.36 1525 0 0 0 0 0 0 0 0 -f 2 glazing, dr outr, 0.320 s 23.36 15:25 0 0 0 0 0 0 0' 0 W Frame wall, wd ext, 0.060 s 4.36 1.11 43 39 168 43 55 55 240 61 2 glazing, or outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 4 2 93 53 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazinq, dr outr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W BasemenNoll, light 0.065 w 1.78 0:00 0 0 0 0 0 0 0' 0 W Frame wall, wd ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 �G G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 D Door, wd sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Aftic ceiling, aspha 0.021 1.50 0.97 28 28 41 27' 228 228 342 221 F Belowgrade floor, 1 0.007 0.54 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -2 89 Envelopeloss/gain 303 121 2565 2557 12 a) Infiltration 147 17 872 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 2300 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 450 138 3437 3118 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 12 6 100 455 14 Subtotal 462 145 3537 3573 15 Ductloads -0°% 0% 0 0 -0% 0% 0 0 Total room load 462 145 X53 f 3573 Air required (dm) 22 9 171 232 wheat Ridge Calculations approved byACCAto meet all requirements of Manual J 8th Ed. S„i, - -1� wr°� htiCa�aerfit'�°` y-2'1 Comfort Bo2019-Ma4:33:20 AZZ*Builder by W rig 18.0.32 RSU27046 Page 9 StDuplexes\3300Ames St(South Bldg Riglt).ryp Calc =MJ8 Front Door faces: W Right -J® Worksheet Entine House Ultimate Heating & Cooling 4971 Monaco St, Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves 1 Room name Bed 2 M Bath 2 Exposed wall 13.0 ft 12.8 It 3 Room height 10.0 It heaUcool 10.0 It heat/cool 4 Room dimensions 1.0 x 143.6 It 6.5 x 12.8 it 5 Room area 143.6 fP 82.9 ft Ty Construdion Ll -value Or HTM Area (ftp) Load Area (ft) Load number (Btuh/e-°F) (Btu /V) or perimeter (ft) (Bbh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basement wall, light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 e 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 Door, vd sc type 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basemerrtwall, light 0.065 s 1.20 0.00 0 0 0 0 0 0 0 0 2 glazing, dr out, 0.320 s 23.36 1525 0 0 0 0 0 0 0 0 2glazing, droutr, 0.320 s 23.36 1525 0' 0 0 0 0 0 0 0 W Frame wall, cud ext, 0.060 s 4.36 1.11 130 100 436 111 128 116 504 128 2 glazing, dr outr, 0.320 s 23.36 10.30 0 0 0 0 6 6 140 62 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 6 3 140 80 2glazing, droutr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazinq, dr outr, 0.320 s 23.36 15.62 30 7 701 469 0 0 0 0 W Basernentvall,light 0.065 w 1.78 0.00 0 0 0 0 0 0 0 0 Frame wall, M ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, or outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 Door, vd sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Abicceiling, alpha 0.021 1.50 0.97 144 144 216 139 83 83 124 80 F Below grade floor, l 0.007 0.54 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -31-3 Envelope loss/gain 1353 716 909 348 12 a) Infiltration 449 52 441 51 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6to 13) 1802 998 1349 399 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 116 60 44 23 14 Subtotal 1918 1058 1393 422 15 Dudloads -0% 0% 0 0 -0% 0% 0 0 Total room load 1918 1058 1393 422 Air required (dm) 93 69 671 27 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ��.F wrlgl�tWCWM 2019 -May -2214:33:20 " Comfort Builder by WrigIIsoft 18.0.32 RSU27046 Page 8 St Dtplexes\3300 Ames St (South Bldg Right).rup Calc= MJ8 Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By: Dakota Groves 1 Room name Bath 1 Bed 2 Exposed wall 5.8 It 27.3 ft 3 Room height 10.0 ft heat/000l 10.0 ft heat/cool 4 Room dimensions 5.8 x 9.3 It 1.0 x 177.5 ft 5 Room area 53.2 ft 177.5 ft Ty Construction U -value Or HTM Area (fl) Load Area Or) Load number (Btuh/(t2-°F) (BtuhV) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NiP/S Heat Cool 6 W Basementwall, light 0.065 e 1 78 0.00 0 0 0 0 0 0 0' 0 W Frame wall, M ext, 0.060 e 4.36 1.11 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 1 1 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 Door, M sctype 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basementwall,light 0.065 s 1.20 0.00 0 0 0 0 0 0 0 0 2 glazing, droutr, 0,320 s 23.36 15.25 0 0 0 0 0 0 0 0 -G I -G 2 glazing, dr outr, 0.320 s 23.36 15.25 0 0 0 0 0 0 0 0 W Frame wall, M ext, 0.060 s 4.36 1.11 0 0 0 0 133 133 578 147 G 2 glazing, or outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, or outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazinq, or outr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 w Basementwall, light 0.065 w 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 w 4.36 1.11 58 55 240 61 140 98 428 109 2 glazing, dr outr, 0.320 w 23.36 34.44 3 0 58 86 0 0 0 0 G [��G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 42 0 981 1447 D Door, M sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Atticceiling, aspha 0.021 1.50 0.97 53 53 80 52 178 178 267 172 F Belowgrade floor, 1 0.007 0.54 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 2 336 Envelope loss/gain 378 201 2253 2210 12 a) Infiltration 199 23 942 109 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 2300 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 577 224 3195 2550 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 51 27 53 27 14 Subtotal 628 251 City 8J48 2577 15 Dud loads -0% 0% 0 0 -0% 0% 0 0 Total room load 628 251 Qt eij3 48 5771 2168 Air required (dm) 30 16 b 9IG �.rea/n ®n Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Comfort BtDlderby Wrigh[soft18.0.32RSU27046 2019-May-2214:33:20Pagel St Duplexes\3300 Ames St (South Bldg Right).rupp Calc= MJ8 Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves 1 Room name Kitchen Stair 1 2 Exposed wall 18.5 ft O ft 3 Room height 10.0 ft heatl000l 10.0 ft heat/cool 4 Room dimensions 1.0 x 295.3 ft 4.3 x 15.3 It 5 Room area 295.3 ft 64.8 fF Ty Construction U -value Or HTM Area (ft2) Load Area (ft) Load number (Btuh/ft2--°F) (Bluh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basementwall,light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, tid ext, 0.060 a 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 Door, M sctype 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basementwall, light 0.065 s 120 0.00 0 0 0 0 0 0 0 0 2 glazing, droutr, 0.320 s 23.36 15.25 0 0 0 0 0 0 0 0 L -G 2 glazing, dr outr, 0.320 s 23.36 15.25 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 s 4.36 1.11 185 185 807 206 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 2 glazing, dr oub', 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, or outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazinq, dr outr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W Basement wall, light 0.065 w 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, M ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 t2 G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 Door, M sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Atficceiling,aspha 0.021 1.50 0.97 0 0 0 0 0 0 0 0 F Belowgrade floor, 1 0.007 0.54 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -28810 Envelope loss/gain 807 -82 0 0 12 a) Infiltration 639 74 0 0 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants@ 230 0 0 0 0 Applianoes/other 1200 0 Subtotal (lines 6 to 13) 1446 1192 0 0 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1446 1192 0 0 15 Dudloads -0% 0%1 01 0 -0% 0%1 0 0 Total room load 1446 11920 0 Air required (dm) 70 78 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrlghi�xofit 2019 -May -2214:33:20 Comfort Builder by W rig h tsoft 18.0.32 RSU27046 Page 6 St Duplexes\3300 Ames Sl (South Bldg Rignt).rup Calc= MJ8 Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves 1 Room name Living Dining 2 Exposed wall 38.3 ft 31.5 ft 3 Room height 10.0 It heat/cool 10.0 ft heat/000l 4 Room dimensions 19.8 x 18.5 ft 1.0 x 203.4 ft 5 Room area 365.4 ft' 203.4 IF Ty Construction U -value Or HTM Area (ft) Load Area (ft2) Load number (Btuh&-°F) (Btuh/ff) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) He.t7 Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basement wall, light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 e 4.36 1.11 198 78 338 86 0 0 0 0 G 2 glazing, or outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 G 2 glazing, droutr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11G 2 glazing, or outr, 0.320 e 23.36 34.44 96 0 2243 3306 0 0 0 0 D Door, wd sc type 0.320 e 23.36 7.55 24 24 561 181 0 0 0 0 W Basemerttwalt, light 0.065 s 1.20 0.00 0 0 0 0 0 0 0 0 Et2 gla2ing, dr outr, 0.320 s 23.36 1525 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 1525 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 s 4.36 1.11 185 165 720 183 118 102 443 113 G 2 glazing, dr outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 G 2 glazing, or outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, or outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 20 11 467 267 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 16 9 374 214 2glazinq,droutr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W Basementwall, light 0.065 w 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 w 4.36 1.11 0 0 0 0 198 132 574 146 G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 42 0 981 1447 D Door, wd sctype 0.320 w 23.36 7.55 0 0 0 0 24 24 561 181 C Attic ceiling, aspha 0.021 1.50 0.57 0 0 0 0 0 0 0' 0 F Below grade floor, l 0.007 0.54 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -161 193 Envelope losstgain 4328 3864 2932 2293 12 a) Infiltration 1322 153 1088 126 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 2300 0 0 0 Appliances/other 900 0 Subtotal (lines 6to 13) 5650 4917 4021 2420 Less extemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5650 4917 4021 2420 15 Dudloads -0% 0%1 0 0 -0% 0% 0 0 Total room load 5650 4917 4021 2420 Air required (clm) 2731 320 = 194 ri 157 3 tQ Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A wril�tl stso<Y" Comfort Bolder by W rightsoft 18.0.32 RSU27046 019-Wy-22 14:33:20Page 5 StDiplexes\3300 Ames St(South Bldg Rght).np Calc =MJB Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating 8r. Cooling 4971 Monaco St, Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves 1 Room name Stair B PMr 2 Eposed wall O ft O ft 3 Room height 9.0 It heat/000l 10.0 ft heat/cool 4 Room dimensions 4.0 x 14.3 ft 4.3 x 8.0 ft 5 Room area 57.0 IF 34.0 fF Ty Construction LI -value Or HTM Area (ft) Load Area (ft=) Load number (Btuh/ft-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 W Basement wall, light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, vd ext, 0.060 e 4.36 1.11 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11 G 2glazing, droutr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 Door, M sc type 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basementwall,light 0.065 s 1.20 0.00 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 15.25 0 0 0 0 0 0 0 0 2 glaang, dr outr, 0.320 s 23.36 1525 0 0 0 0 D 0 0 0 W Frame wall, vd ext, 0.060 s 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazinq, droutr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W Basement wall, light 0.065 w 1.78 0.00 0 0 0 0 0 0 0 0 W Frame well, wd ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 t2 G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 Door, vd sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Afficoeiling,aspha 0.021 1.50 0.97 0 0 0 0 0 0 0 0 F Below grade floor,) 0.007 0.54 0.00 57 57 31 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 31 0 0 0 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal (lines 6 to 13) 31 0 0 0 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -31 0 0 0 14 Subtotal 0 0 0 0 15 Dudloads -0% 0% 0 0 -0%10% 0 0 Total room load 00 0 0 Air required (clm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. TT Wrl tsisolwt' 2019 -May -22143320 Mn,,.._.. «w, ComfortBolder by W rigttsoft 18.0.32 RSU27046 Page 4 ..St Diplexes\3300 Ames St (South Bldg Rigft).rup Calc= MJ8 Frort Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By: Dakota Groves 1 Room name Fut Room 2 Unf Bsmt 2 Exposed wall 27.3 ft 19.0 ft 3 Room height 9.0 ft heaUcool 9.0 ft heat/cool 4 Room dimensions 11.8 x 15.5 ft 1.0 x 360.3 It 5 Room area 182.1 ft' 360.3 ft2 Ty Construction Ll -value Or HTM (ft) Area(ftp) Load Area Load number (Btuh/fV-°F) (Btuh/fF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basement wall, light 0.065 e 1.78 0:00 106 106 189 0 0 0 0 0. W Frame wall, M ext, 0.060 e 4.36 1.11 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 D Door, wd sctype 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 iiW _ Basementwall,light 0.065 s 1.2{3 0.00 140 120 154 0' 171 139 153 0 2 glazing, droutr, 0.320 s 23.36 1525 0 0 0 0' 32 9 748 488 2 glazing, dr outr, 0:320 s 23.36 1525 20 5 467 305 0 0 0 0 W Frame wall, vA ext, 0.060 s 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2glazinq,droutr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W Basement wall, light 0.065 w 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, vtd ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, dr out,, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 �G G 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 D Door, vai sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Attic ceiling, aspha 0.021 1.50` 0.97 0 0 0 0 0 0 0 0 F Belowgradefioor,1 0.007 0.54 0.00 182 182 98 0 360 360 194 0 6 c) AED excursion 23 -66 Envelope loss/gain 907 328 1094 422 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 230 900 Subtotal (lines 6to13) 907 558 1094 1322 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 00 72 0 14 Subtotal 907 558 1166 1322 15 Ductloads -0% 0% 0 0 -0% 0% t%' 0 Total room load 907 5581122 Air required (dm) 44 36 V':61 R'sd9 86 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Building Division AQZ�.e!�?!! 2019 -May -22 14:33:20 AZZKComfort Bolder by Wrightsoft 18.0.32 RSU27046 Page 3 St DLrplexes\3300 Ames St (South Bldg Rignt).rrp Calc= MJ8 Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St, Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves 1 Room name Mech Fut Room 1 2 Exposed wall 8.0 It 26.0 ft 3 Room height 9.0 It heat/cool 9.0 ft heat/cool 4 Room dimensions 8.0 x 14.3 ft 11.8 x 14.3 ft 5 Room area 114.0 ft' 167A ft2 Ty Constudion Ll -value Or HTM Area (IF) Load Area (ft) Load number (Btuh/t-T) (Btuh/ft�) or perimeter (ft) (Btuh) or perimeter (ft) (Btih) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Basementwall, light 0.065 a 1.78 0.00 0 0 0 0 0 0 0 0 W Frame wall, wd ext, 0.060 e 4.36 1.11 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 11 G 2 glazing, dr outr, 0.320 e 23.36 34.44 0 0 0 0 0 0 0 0 Door, wd sctype 0.320 e 23.36 7.55 0 0 0 0 0 0 0 0 W Basementwdll,light OA65 S 1.20 0.00 0 0 0 0 128 108 133 0 2 glazing, droutr, 0.320 s 23.36 1525 0 0 0 0 0 0 0 0 2 glazing, dr out', 0.320 s 23.36 1525 0 0 0 0 20 5 467 305 W Frame wall, wd ext, 0.060 s 4.36 1.11 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 10.30 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 0 0 0 0 0 0 0 0 2 glazinq, dr outr, 0.320 s 23.36 15.62 0 0 0 0 0 0 0 0 W Basementvall,light 0.065 w 1.78 0.00 72 72 128 0 406 106 189 0 W Frame wall, wd ext, 0.060 w 4.36 1.11 0 0 0 0 0 0 0 0 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 G [�2 2 glazing, dr outr, 0.320 w 23.36 34.44 0 0 0 0 0 0 0 0 Dow, wd sctype 0.320 w 23.36 7.55 0 0 0 0 0 0 0 0 C Aticceiling,aspha 0.021 1.50 0.97 0 0 0 0 0 0 0 0 F Belowgrade floor, 1 0.007 0.54 0.00 114 114 61 0 167 167 90 0 6 c) AED excursion 0 23 Envelope loss/gain 190 0 879 328 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 230 Subtotal (lines 6 to 13) 190 0 879 558 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution -190 0 148 0 14 Subtotal 0 0 1028 558 15 Ductloads -0% 0°% 0 0 -0% 0°% 0 0 Total room load0 0 1028 558 Air required (dm) 0 0 50 36 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -fiJa- 2019 -May -2214:33:20 Comfort Bulder by W rigFtsoft 18.0.32 RSU27046 Page 2 St Drplexes\3300 Ames St (South Bldg Right).rua Calc= MA Front Door faces: W Right -J® Worksheet Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves 1 Room name Entire House Fut Bath 2 Exposed wall 264.8 It 8.0 It 3 Room height 9.7 ft d 9.0 ft heat/000l 4 Room dimensions 8.0 x 10.3 ft 5 Room area 2888.4 T 82.0 ft' Ty Construdion Ll -value Or HTM Area (IV) Load Area (ft2) Load number (Btuh/fF--°F) (Btuh/ft-) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 W Basementwall,light 0.065 a 1.78 0.00 178 178 317 0 72 72 128 0 W Frame wall, wd ext, 0.060 e 4.36 1.11 395 216 942 240 0 0 0 0 G 2 glazing, dr outr, 0.320 e 23.36 34.44 5 0 117 172 0 0 0 0 G 2 glazing, dr out-, 0.320 e 23.36 34.44 54 0 1261 1860 0 0 0 0 11G 2 glazing, dr out-, 0.320 e 23.36 34.44 96 0 2243 3306 0 0 0 0 D Door, wd sctype 0.320 e 23.36 7.55 24 24 561 181 0 0 0 0 W Basement wall, light 0.065 s 1.20 000 439 367 439 0 0 0 0 0 [:::G 2 glazing, droutr, 0.320 s 23.36 1525 32 18 748 488 0 0 0 0 G 2 glazing, dr outir, 0.320 s 23.36 15.25 40 22 934 610 0 0 0 0 W Frame wall, wd ext, 0.060 s 4.36 1.11 975 893 3896 993 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 10.30 6 12 140 62 0 0 0 0 2 glazing, droutr, 0.320 s 23.36 13.37 4 4 93 53 0 0 0 0 G 2 glazing, dr outr, 0.320 s 23.36 13.37 6 7 140 80 0 0 0 0 2 glazing, dr outr, 0.320 s 23.36 13.37 20 22 467 267 0 0 0 0 G 2 glazing, dr out-, 0.320 s 23.36 13.37 16 18 374 214 0 0 0 0 G 2 qlazinq, dr out-, 0.320 s 23.36 15.62 30 13 701 469 0 0 0 0 W Basementwail,light 0.065 w 1.78 0.00 178 178 317 0 0 0 0 0 W Frame wall, wd ext, 0.060 w 4.36 1.11 395 285 1241 316 0 0 0 0 2 glazing, dr out-, 0.320 w 23.36 34.44 3 0 58 86 0 0 0 0 �G G 2 glazing, dr outr, 0.320 w 23.36 34.44 84 0 1962 2893 0 0 0 0 D Door, wd sctype 0.320 w 23.36 7.55 24 24 561 181 0 0 0 0 C Aiticceiling, aspha 0,021 1.50 0.97 963 963 1446 933 0 0 0 0 F Belowgrade floor, 1 0.007 0.54 0.00 963 963 519 0 82 82 44 0 6 c) AED excursion 0 0 Envelope loss/gain 19478 13406 173 0 12 a) Infiltration 6099 707 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 3960 0 Subtotal (lines 6 to 13) 25577 18993 173 0 Less edema/ load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 25577 18993 173 0 15 Dudloads 0% 0% 0 0 -0% 0% 0 0 Total room load 25577 18993 173 0 Air required (dm) 1235 1235 wh 0 f ".Y9 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Building Divisor) Tt =ham 2019 -May -22 14:33:20 Comfort B alder by Wrightsoft 18.0.32 RSU27046 Page 1 St DLplexes\3300 Ames St (South Bldg Right).rup Calc= MJ8 Front Door faces: W Project Summary Entire House Ultimate Heating & Cooling 4971 Monaco St, Commerce City, CO 80022 For: Feaster Realty 3300 Ames Street, Wheatridge, CO 80212 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves Notes: Modeled to comply with 2012 IECC. Heat loss assumed RH 30% at 70"f. Ventilation modeled compliance with ASHRAE 62.2-2010. Design Information Weather: Denver Stapleton Intl AP, CO, US Winter Design Conditions Summer Design Conditions Outside db -3 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 73 °F Design TD 16 °F Daily range H Heating output Relative humidity 50 % Moisture difference -34 gr/Ib Heating Summary Structure 25577 Btuh Ducts 0 Btuh Central vent (59 cfm) 3893 Btuh Outside air Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 3696 Btuh 0 Btuh 33165 Btuh Simplified Semi -ti ht 1 (Tight) Heating Cooling Area (ft) 2888 2888 Volume (ft) 19769 19769 Air changes/hour 0.28 0.15 Equiv AVF (cfm) 92 49 Heating Equipment Summary Make Carrier Trade Carrier Comfort 92 Single -Stag... Model 59SC2C060S17-16 AHRI ref Sensible Cooling Equipment Load Sizing Structure 18993 Btuh Ducts 0 Btuh Central vent (59 cfm) 842 Btuh Outside air Sensible cooling Heating output Blower 1707 Btuh Use manufacturer's data y Rate/swingg multipplier 1.00 Equipmentsensibleload 21542 Btuh Latent Cooling Equipment Load Sizing Structure -127 Btuh Ducts 0 Btuh Central vent (59 cfm) -1105 Btuh Outside air Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 21542 Btuh Req. total capacity at 1.00 SHR 1.8 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 24ABB330ABN3 Coil CNPVP3717ALA 11.0 EER, 13 SEER 24840 Btuh 0 AHRI ref Efficiency 92.1 AFUE Efficiency Heating input 60000 Btuh Sensible cooling Heating output 49680 Btuh Latent cooling Temperature rise 44 °F Total cooling Actual airflow 1235 cfm Actual airflow Air flow factor 0.048 cf-nBtuh Air flow factor Static pressure 0.90 in H2O Static pressure Space thermostat Load sensible heat ratio 11.0 EER, 13 SEER 24840 Btuh 0 Btuh 24840 Btuh 1235 cfm 0.065 cfm/Btuh 0.90 in H2O 1.00 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. AW wr➢gFftSoft- 2019 -May -2214:33:20 ComfortBulder by WriglIsoft 18.0.32 RSU27046 Page 1 St Diplexest3300 Ames St (Souh Bldg Rigk).rLp Calc= MJ8 Frort Door faces: W 2 glazing, dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk: 2 glazing, s k dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.40); 50% drapes, medium; 1 ft overhang (1 ft window ht, 1.5 ft w sep.); 7 ft head ht all 2 glazing, dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk: 2 glazing, s dr outr, air gas, wd fan mat, dr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.40); 50% drapes, medium; 1 ft overhang (5 ft window ht, 1.5 ft sep.); 7 ft head ht Doors 6 0.320 0 23.4 140 10.3 62 3 0.320 0 23.4 58 34.4 86 9 0.320 0 23.4 199 17.4 148 30 0.320 0 23.4 701 15.6 469 Door, wd sc type e 24 0.320 w 24 0.320 all 48 0.320 Ceilings Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int 963 0.021 fnsh Floors Below grade floor, light dry soil, 9' depth 963 0.007 ` wrightsoft. Comfort Biilder by W rigriwft 18.0.32 RSU27046 ...StDLplexes\3300Ames St(SodhBldg Riglt).rLp Calc =MJ8 Frort Door faces: W 0 23.4 561 7.55 181 0 23.4 561 7.55 181 0 23.4 1121 7.55 362 49.0 1.50 1446 0.97 933 0 0.54 519 0 0 04 of '41X'Ook R�d90 14:33:20 Page 2 Component Constructions Job: 3300 Ames St F' Date: 05/22/2019 Entire House By: Dakota Groves Ultimate Heating & Cooling 4971 Monaco St, Commerce City, CO 80022 For: Feaster Realty 3300 Ames Street, W heatridge, CO 80212 Location: Denver Stapleton Intl AP, CO, US Elevation: 5285 ft Latitude: 40 ° N Outdoor. Heating Dry bulb (°F) -3 Daily range (°F) - Wet bulb (°F) - Wind speed (mph) 20.0 Indoor. Heating Cooling 70 Indoor temperature (°F) 73 Design TD (°F) 30 Relative humidity (%) Cooling Moisture difference (grAb) 91 Infiltration: 27 (H ) Method 60 Construction quality 7.5 Fireplaces Heating Cooling 70 75 73 16 30 50 35.2 -33.5 Simplified Semi -tight 1 (Tight) Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain 0.320 0 ft' BtuWWF ft''FBluh Btuhlft' Bluh BtuWft' Btuh Walls 140 13.4 80 20 0.320 0 23.4 467 Basement wall, light dry soil, 2'x6" wood int frm, concrete wall, r-19 cav ins, e 178 0.024 19.0 1.78 317 0 0 8" thk, 5/8" gypsum board int fnsh s 367 0.024 19.0 1.20 439 0 0 0 W 178 0.024 19.0 1.78 317 0 0 1962 all 722 0.024 19.0 1.49 1073 0 0 Frame Wall, wd ext, 3/8" wood shth, r-20 cav ins, 1/2" gypsum board int a 216 0.060 20.0 4.36 942 1.11 240 fnsh, 2'x6" wood frm, 16" o.c. stud s 893 0.060 20.0 4.36 3896 1.11 993 23.4 W 285 0.060 20.0 4.36 1241 1.11 316 15.2 all 1394 0.060 20.0 4.36 6080 1.11 1549 Partitions (none) Windows 2 glazing, dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk: 2 glazing, e dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk; NFRC rated s (SHGC=0.40); 50% drapes, medium; 1 ft overhang (2 ft window ht, 1.5 ft s sep.); 7 ft head ht s s all 2 glazing, dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk: 2 glazing, e dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.40); 50% drapes, medium; 1 ft overhang (6 ft window ht, 1.5 ft W sep.); 7 ft head ht all 2 glazing, dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk: 2 glazing, e dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.40); 50% drapes, medium; 1 ft overhang (8 ft window ht, 1.5 ft sep.); 7 ft head ht 2 glazing, dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk: 2 glazing, s dr outr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.40); 50% drapes, medium; 1 ft overhang (4 ft window ht, 1.5 ft s sep.); 7 ft head ht all 5 0.320 0 23.4 117 34.4 172 4 0.320 0 23.4 93 13.4 53 6 0.320 0 23.4 140 13.4 80 20 0.320 0 23.4 467 13.4 267 16 0.320 0 23.4 374 13.4 214 51 0.320 0 23.4 1191 15.4 787 54 0.320 0 23.4 1261 34.4 1860 84 0.320 0 23.4 1962 34.4 2893 138 0.320 0 23.4 3224 34.4 4753 96 0.320 0 23.4 2243 34.4 3306 32 0.320 0 23.4 748 15.2 488 40 0.320 0 23.4 934 15.2 610 72 0.320 0 23.4 1682 15.2 1098 t '*' wrightsoft.. 2019 -May -2214:33:20 ComfortBulder by Wrigrtsoft 18.0.32 RSU27046 Page 1 St Dlplexes\3300 Ames St (Soup Bldg Rigrt).rlp Calc = MJ8 Frort Door faces: W Building Analysis Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Project Information For: Feaster Realty 3300 Ames Street, Wheatridge, CO 80212 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves Heating Component Design Conditions % of load Walls Location: 7154 Indoor: Heating Cooling Denver Stapleton Intl AP, CO, US 27.9 Indoor temperature (°F) 70 75 Elevation: 5285 ft Ceilings Design TD (°F) 73 16 Latitude: 40°N 0.5 Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 35.2 -33.5 Dry bulb (°F) -3 91 Infiltration: 0 Daily range (°F) - 27 ( H ) Method Simplified 11.1 Wet bulb (°F) - 60 Construction quality Semi -tight Adjustments Wind speed (mph) 20.0 7.5 Fireplaces 1 (Tight) 1 Heating Component Btuh/ft2 Btuh % of load Walls 3.4 7154 21.6 Glazing 23.4 9239 27.9 Doors 23.4 1121 3.4 Ceilings 1.5 1446 4.4 Floors 0.5 519 1.6 Infiltration 3.5 6099 18.4 Ducts 0 0 Piping 0 0 Humidification 3696 11.1 Ventilation 3893 11.7 Adjustments 0 Total 1 33165 100.0 Cooling Component Btuh/ft2 Btuh %of load Walls 0.7 1549 7.2 Glazing 26.7 10561 49.0 Doors 7.6 362 1.7 Ceilings 1.0 933 4.3 Floors 0 0 0 Infiltration 0.4 707 3.3 Ducts 0 0 Ventilation 842 3.9 Internal gains 4880 22.7 Blower 1707 7.9 Adjustments 0 Total 1 1 215421 100.0 Latent Cooling Load = 0 Btuh Overall U -value = 0.060 Btuh/ft2-°F Data entries checked. Glazing Glazing umidification /entilation nfiltration :ion nternal Gains ration mer '3 Oth city of Wheat Ridge wrightsaft- 2019 -May -2214:33:20 ,.r,. «- s >- Comfort B Dlder by W rigFRsoft 18.0.32 RSU27046 Page 1 ACC�K ...St Duplexes\3300 Ames St (South Bldg Right).r-p Calc= MJ8 Front Door faces: W M Bath 83 1393 422 67 27 TC 28 462 145 22 9 M Bed 228 3537 3573 171 232 M CIO 56 0 0 0 0 Laundry 27 0 0 0 0 Stair 2 49 0 0 0 0 Hall 118 0 0 0 0 Entire House d 2888 25577 18993 1235 1235 Other equip loads 7588 2549 Equip. @ 1.00 RSM 21542 Latent cooling 0 TOTALS ' 2888 ' 33165 ' 21542 ' 1235 ' 1235 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft, 2019 -May -22 14:33:20 Comfort Bulder by W rigMsoft 18.0.32 RSU27046 Page 2 f CCK ...St DLpIexes13300 Ames St (SOUK Bldg Rigft).r p Calc = MJ8 Frort Door faces: W Load Short Form Entire House Ultimate Heating & Cooling 4971 Monaco St., Commerce City, CO 80022 Project Information For: Feaster Realty 3300 Ames Street, Wheatridge, CO 80212 Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves ROOM NAME Area (ft2) Design Information Htg AVF (cfm) Clg AVF (cfm) Fut Bath Htg Clg Infiltration 8 0 Outside db (°F) -3 91 Method Simplified 0 Inside db (°F) 70 75 Construction quality Semi -tight Design TD (°F) 73 16 Fireplaces 558 1 (Tight) Daily range - H 1166 1322 56 Inside humidity (%) 30 50 0 0 0 Moisture difference (grAb) 35 -34 0 0 0 HEATING EQUIPMENT Living COOLING EQUIPMENT 5650 Make Carrier 273 320 Make Carrier 203 4021 Trade Carrier Comfort 92 Single -Stag... 157 Trade CARRIER 295 1446 Model 59SC2C060S17--16 70 78 Cond 24ABB330ABN3 65 0 AHRI ref 0 Cit' of 0 Coil CNPVP3717ALA 53 628 251 30 16 AHRI ref 178 3248 Efficiency 92.1 AFLIE Wheat Ridge168 Efficiency 11.0 EER, 13 SEER 1010 Heating input 60000 Btuh Sensible cooling 24840 Btuh Heating output 49680 Btuh Latent cooling 0 Btuh Temperature rise 44 °F Total cooling 24840 Btuh Actual airflow 1235 cfm Actual airflow 1235 cfm Airflowfactor 0.048 cfm/Btuh Air flow factor 0.065 cfm/Btuh Static pressure 0.90 in H2O Static pressure 0.90 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Fut Bath 82 173 0 8 0 Mech 114 0 0 0 0 Fut Room 1 167 1028 558 50 36 Fut Room 2 182 907 558 44 36 Unf Bsmt 360 1166 1322 56 86 Stair B 57 0 0 0 0 Pwdr 34 0 0 0 0 Living 365 5650 4917 273 320 Dining 203 4021 2420 194 157 Kitchen 295 1446 1192 70 78 Stair 1 65 0 0 0 Cit' of 0 Bath 1 53 628 251 30 16 Bed 178 3248 2577 157 Wheat Ridge168 P-1 ') 1 sl A 1010 1 r1G4 nn — Building Division Calculations approved byACCAto meet all requirements of Manual J 8th Ed. * wrig ,htsoft 2019 -May -2214:33:20 e,,,, ,�...„.„�;.;,,,w;,, Comfort Btnlder by Wrigttsoft 18.0.32 RSU27046 Page 1 ...StDuplexes\3300Ames St(South Bldg Right).rup Calc =W8 Frort Door faces: W Manual S Compliance Report Entire House Ultimate Heating & Cooling 4971 Monaco St, Commerce City, CO 80022 For: Feaster Realty 3300 Ames Street, W heatridge, CO 80212 Design Conditions Outdoor design DB: 90.8°F Sensible gain: 21542 Btuh Outdoor design WB: 60.1 °F Latent gain: 0 Btuh Indoor design DB: 75.0°F Total gain: 21542 Btuh Indoor RH: 50% Estimated airflow: 1235 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Carrier Model: 24ABB330ABN3+CNPVP3717ALA Actual airflow: 1235 cfm Sensible capacity: 24840 Btuh 115% of load Latent capacity: 0 Btuh 0% of load Total capacity: 24840 Btuh 115% of load SHR: Ok% Heating Equipment Design Conditions Outdoor design DB: -3.0°F Heat loss: 33165 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Carrier Model: 59SC2CO60S17-16 Actual airflow: 1235 cfm Output capacity: 49680 Btuh 150% of load Meets all requirements ofACCA Manual S. Job: 3300 Ames St Date: 05/22/2019 By. Dakota Groves Entering coil DB: 77XF Entering coil WB: 62.1°F Entering coil DB: 66.5°F Temp. rise: 51 °F 1 * wrightsoft, 2019 -May -2214:33:20 f��''', ComfortBiilder by W rigfisoft 18.0.32 RSU27046 Page 1 /� r�fR ...St D�plexest.3300 Ames St (SoLth Bldg Rigtt).rup Calc= MJ8 Frond Door faces: W City of Wheat Ridge Site Work Permit PERMIT - 201901154 PERMIT NO: 201901154 ISSUED: 06/14/2019 JOB ADDRESS: 3300 Ames St EXPIRES: 06/13/2020 JOB DESCRIPTION: Site work for the construction of two duplexes. All construction will be done in one phase- total site is 0.43 acres. Construction to include a private alley, utility laterals, landscaping, and water quality pond. *** CONTACTS *** OWNER FEASTER JAY SUB (303)369-7977 TOMMY CAGLE 190113 Q BUILDERS, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 66,000.00 FEES Total Valuation 0.00 Plan Review Fee 557.93 Use Tax 1,386.00 Permit Fee 858.35 Engin. Review Fee 1,700.00 ** TOTAL ** 4,502.28 *** COMMENTS *** *** CONDITIONS *** All work shall comply 2012 International Codes, 2017 NEC (if applicable), and ordinances adopted by the City of Wheat Ridge. Work is subject to field inspections. No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. '* * A *1 City of Wheat Ridge „r r Site Work Permit PERMIT - 201901154 PERMIT NO: 201901154 ISSUED: 06/14/2019 JOB ADDRESS: 3300 Ames St EXPIRES: 06/13/2020 JOB DESCRIPTION: Site work for the construction of two duplexes. All construction will be done in one phase- total site is 0.43 acres. Construction to include a private alley, utility laterals, landscaping, and water quality pond. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am leg ally a zed to include alI entities named within this document as parties to the work to be perform /� ll�work be perfo sclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNED --CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services ce or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. FOR OFFICE USE ONLY city of Com Date: Plan/Permit # Building & Inspection Services '� a/ � 011,5 7500 W. 29«' Ave., Wheat Ridge, CO 80033 Plan Review Fee:�j o/ Office: 303-235-2855 * Fax: 303-237-8929 l� O Y Inspection Line: 303-234-5933 Email: perm its(a�ci.wheatridge.co.us Building Permit Application *` Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 3300 Ames St. Wheat Ridge, CO Property Owner (please print): Jay Feaster Phone: Property Owner Email: jay@feasterrealty.com Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: 19510 W. 55th PI. Citv, State, Zip: Golden, CO 80403 Arch itegVEnginee r: Michael Fiebig, AIA / Fiebig Architecture Arch itecfi/Engineer E-mail: michael@fiebigarch.com phone: 303.594.7584 Contractor Name: Tommy Cagle / Q Builders LLC City of Wheat Ridge License #: 190113 Contractor E-mail Address: gbuilders123@gmail.com For Plan Review Questions & Comments (please print): Phone: 303.369.7977 CONTACT NAME (please print): Jesse Donovan Phone: CONTACT EMAIL(please print) jesse@brightlightereng.com 720.504.8629 Sub Contractors (Mist provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. ❑COMMERCIAL [X RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Site development for the construction of two duplexes at 3300, 3308, 3316, and 3324 Ames Street. All construction will be done in one phase - total site area is 0.43 acres, more or less. Construction to include a private alley, utility laterals, landscaping, water quality pond, etc. Sq. FULF BTUs Gallons Amps Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that i am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that e this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided o e appli tion. CIRCLE ONE: (OWNER) (CON or AUTHORIZED REPRESENTATIVE of OWNER (CONTRACTOR) Signature (first and last name): DATE: 06/05/2019 Printed Mame: Jesse Dono n for Feaster Realty DEPARTMENT USE ONLY ZONING COMMMENTS: Y A AD ev Qtz.eo (Dist -1 Ci Reviewer; dQ..� BUILDING DEP MEN T COMA -NTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer. AWS &I Im OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: _) J l R ti hCity of PUBLIC WORKS City of Wheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 PUBLIC WORKS DEVELOPMENT REVIEW FEES Date: /O �)t YA/F Location of Construction: Purpose of Construction: 2 zMeW Single Family Commercial Multi -Family _V Development Review Processing Fee: ................................................ $100.00 (Required of all projects for document processing) Single Family Residence/Duplex Review Fee: ..................................... $50.00 $ Commercial/Multi-Family Review Fees: (Fees include reviews of the 1st and 2°d submittals • Review of existing or minimal technical documents: ........................ $200.00 $ • Initial review' of technical civil engineering documents: ................ $600.00 $ &C2Q29 • Traffic Impact Study Review Fee: .................................................... $600.00 $ • Trip Generation Study Review Fee: .................................................. $200.00 $ • Stormwater Management Plan (SWMP) Review Fee: ....................... $200.00 $ • O & M Schedule Review & SMA Recording Fee ............................. $100.00 $ • Construction Control Plan................................................................. $100.00 $ /DD. DLJ Each Application will be reviewed by staff once and returned for changes. If after review of the second submittal changes requested by staff have not been fully made to the civil/stormwater/traffic documents, further reviews will be subject to the following Resubmittal Fees: • Resubmittal Fees: 31 submittal ('/2 initial review fee): .................................................... $300.00 $ ap 41h submittal (full initial review fee) :................................................. $600.00 $ All subsequent submittals: ................................................................. $600.00 X = $ (Full initial review fee) TOTAL. REVIEW FEES (due at time of Building Permit issuance): $ /,700, PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE LICENSING AND PERMITTING FEES REQUIRED TO CONSTRUCT IMPROVEMENTS AND UTILITIES WITHIN THE PUBLIC RIGHT-OF-WAY. www.ci.wheatridge.co.us Rev 05/19 BRIGHTLIGHTER ENGINEERING LLC 3253 N. GAYLORD ST. DENVER, CO 80205 (720) 540-8629 (Phone) Opinion of Probable Cost Date: 26 -Apr -19 Project: FR1901 Location: Wheat Ridge, CO By: JSD 1 ON-SITE IMPROVEMENTS Quantity Unit Unit Cost Total 2 Alley 1 EA $14,000.00 $14,000.00 3 Landscaping 1 EA 30,000.00 $30,000.00 4 Grading/Ponds 1 EA $1070.00 10,000.00 5 Walks 1 EA 6,000.00 $6,000.00 s Flatwork/Patios 1 EA 6,000.00 670.00 a Contingency 25% $16,500.00 12 *The above cost estimate numbers are based on information provided by the Contractor, and are subject to change based on fluctuations in the cost of labor and materials. BRIGHTLIGHTER ENGINEERING LLC 3253 N. GAYLORD ST. DENVER, CO 80205 (720) 540-8629 (Phone) Opinion of Probable Cost Date: 26 -Apr -19 Project: FR1901 Location: Wheat Ridge, CO By: JSD t OFF-SITE IMPROVEMENTS Quantity Unit Unit Cost Total z 6" Sidewalk 1400 1 SF $10.00 $14,000.00 3 Curb and 2' Gutter 270 LF 30.00 8,100.00 4 Asphalt - Match Existing Thickness 1800 SF $10.00 $18,000.00 5 Alley Entrance 1 EA 7,500.00 7,500.00 6 ADA Ramp 2 EA 1,500.00 3,000.00 e Contingency 25% 12,650.00 11 iz , ' >ti; . " NTS $93160.0 'The above cost estimate numbers are based on information provided by the Contractor, and are subject to change based on fluctuations in the cost of labor and materials. CITY OF WHEAT RIDGE PUBLIC WORKS, ENGINEERING APPROVED FOR: o DRAINAGE 0 SIDEWO&K 0 CURS & GUTTER 0 STREET Rf MISCELLANEOUS d PLAT i Itemized Engineers Cost Estimate CQMMENT 05108n0119 CML ENGINEER SUBJECT TO FIELD INSPECTIONS CITY OF WHEAT RIDGE PUBLICWORKS DATE 04/29/2019 RECEIVED 04/29/2019 5th Submittal T-1,-. City Of W heat -Midge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P:303.235.2846 F:303.235.2857 January 25, 2019 OFFICIAL ADDRESS NOTIFICATION NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: NEW ADDRESS: 3300, 3308, 3316, 3324 Ames Street CURRENT ADDRESS: Vacant Lot • Subdivision: Columbia Heights Resub of Blk 5, Lot 10 and 11, Tract/Key AB, Section Parcel # 39-251-12-009 NOTES: This is a courtesy notification. This addressing is preliminary noticing for water and sanitation taps and electric meters only. AUTHORIZED BY: DATE: DISTRIBUTION: 1. Property Owner 2. Applicant 3. Xcel Energy, sandra.cardenas(&xcelenergy.com 4. Wheat Ridge Water District 5. Wheat Ridge Sanitation District 6. Wheat Ridge Building Division 7. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: DATE: www.d.wheatridge.co.us Vicinity Map 3300AA,1ES STREET. WNFAT ROW. OOLORADOOM12 UYr510 AND 11JOGETHER WITH THE WEST tf3 OF THE VACATED AUZY AWOOMO SAGO LOTS. A AMOCIVOOM OF OL= 5 OF OOLW W IA "COM, =PM OF JAN. STATE OF OQ MjWO / w � -yr• �____ _• _ as rte• aain � i�ann+wn sFu» A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE 4 Inspection Type:E t Job Address: ,� � 66 A rye -f cel Permit Number: ;_ A 0 01__ t 1 a f i ❑ No one available for inspection: Time 0` it �� AM/PM Re -Inspection required:Ce)No When corrections have been made, schedule for re -inspection online at: http.11www. ci. wheatridge. co. ushnspection Date: Inspector: f1 DO NOT REMOVE THIS NOTICE AZawas ec Retrotec rCloud Quality Assurance Report Single Direction Multi Point Blower Door Test PASS Your Result: 1.71 ACH50 (796.18 CFM60 * 60 / 27921 ft) Target < 4 ACH50 Test Information Test Name Test Date Export id Company Name Technician Name Technician Email Building Information Address City State Zip/postal Code Country Year Constructed Elevation Address Verified? Building Latitude, Longitude GPS validation Estimated Distance From Address Test Equipment Fan Model Fan Serial Number Pressure Gauge Model Gauge Serial Number Environmental Conditions Pre-test Indoor Temperature Pre-test Outdoor Temperature Wind Speed Average Barometric Pressure Test Dimensions Conditioned Floor Area Envelope Area Volume 3300 Ames St 2020-05-05 09:32 AM (MDT) U9DO3JYF Ultimate Heating & Cooling Kyle Massler kyle@uhcdenver.com 3300 Ames St Wheat Ridge CO 80212 United States 2020 5469 ft Yes 39.764028, -105.054404 Latitude/Longitude: 39.763947. -105.054333: Accuracy: 16 ft 27 ft Retrotec 1000/2000 1FN002062 Retrotec DM 32 10A 402271 75 °F 55 °F 0 MPH 102.6 kPa 2888 ft2 2559 ft2 27921 ft3 retry" Test Results Summary Test Type Flow Reference Pressure Time Averaging Corrected Flow Air Changes Per Hour Percent Uncertainty Correlation Intercept Slope Test Results Test Data Set 1 Flow Direction Gauge Location Retrotec rCloud Single Direction Multi Point Blower Door Test 50 Pa 10 seconds 796.18 CFM @ 50 Pa 1.711 2.3% 0.998 48.299 0.716 Depressurize Inside Baseline Pressure, Initial (Pa) -0.1 -0.1 -0.1 -0.1 -0.2 -0.2 -0.2 -0.2 -0.2 -0.3 Baseline Duration 16 seconds Average baseline -0.17 Pa Measured Pressure (Pa) -15.05 -22.45 -29.34 -37.31 Fan Pressure [1000/2000 - C8] (Pa) 17.51 29.29 42.22 Fan Pressure [1000/2000 - B] (Pa) 13.62 Flow (CFM) 332.47 430.64 518.02 645.41 Measured Pressure (Pa) -45.3 -52.23 -61.26 Fan Pressure [1000/2000 - C8] (Pa) Fan Pressure [1000/2000 - B] (Pa) 17.54 21.03 26.7 Flow (CFM) 732.41 801.98 903.65 Baseline Pressure, Final Pa -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.4 -0.3 -0.3 -0.3 Baseline Duration 14 seconds Average baseline -0.37 Pa 2 �rerroL"� Test Notes No notes entered. Flow Equation Parameters - Factory Default Retrotec rCloud Fan Model Retrotec 1000/2000 Fan Serial Number 1 FN002062 Flow equation parameters - 1131 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self -referenced fan or when the room pressure is negative. If using a fan which is not self -referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. If PrA is greater than 0 or fan is self -referencing: FP = jPrBj - PrA If PrA is less than 0 or fan is self -referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x IRPI) rN = tan pressure, KF' = room pressure Range N K K1 K2 K3 K4 MF Open 0.5214 519.6183 -0.0700 0.8000 -0.1150 1 8.6 A 0.5030 264.9959 -0.0750 1.0000 0.0000 1 12 B 0.5000 174.8824 0.0000 0.3000 0.0000 1 10 C8 0.5000 78.5000 -0.0200 0.5000 0.0160 1 10 C6 0.5050 61.3000 0.0540 0.5000 0.0040 1 10 C4 0.5077 42.0000 0.0090 0.5000 0.0005 1 10 C2 0.5200 22.0000 0.1100 0.5000 -0.0010 1 10 C1 0.5410 11.9239 0.1300 0.4000 0.0014 1 10 L4 0.4800 4.0995 0.0030 1.0000 0.0004 1 10 L2 0.5020 2.0678 0.0000 0.5000 0.0001 1 10 L1 0.4925 1.1614 0.1000 0.5000 0.0001 1 10 flow =(FP - RIP xK1)"x(K+K3x FP) x K4 3