HomeMy WebLinkAbout4050 Clear Creek DriveU
United Test and Balance
T jA\B 10440 Bradford Rd. Unit C
Littleton, CO 80127
Certified Testing, Adjusting, and Balancing Report
Project Information
Proitu t Name:
CCC: Building 4
Report Revision Infortraion
Addresec
4044Clear, Creek Dr.
cmnmunry • planning s
arcHnch"
V✓hrat Ridge, Co
Elevation:
5,459 ft
Reviewing Supervisor Signature
Certified ReWnt Dare:
August 30,2021
M ngUty o��orar,mr+ aaws
SDVOSB
s. E-R,b @ubNW1omm.
Jeremy James Merrill o." u.ubo,b na a oOb W,-
,m
Mn
TNN Nnd M...
Contractor Information
Mechanical Contractor: CBA Mechardcal
Mechardcal Entineee
528O�Engineering
20-320-7744
?Blank 528olEngineering 8-31-2021
OUTLOOK CLEARCREEK CROSSING
Buildina 4
Approved as SUBMITTED
Architece
v v
-
KEPHART
cmnmunry • planning s
arcHnch"
2555 WAI NOT S RPVT
N NVI'. R.0 DRAW
095
..,.Ao,Nws.[ar,
Information
Semper )Fidelis
Veteran Owned and Operated
v v
-
—
SDVOSB
,m
TNN Nnd M...
,wbbNd
Semper )Fidelis
Veteran Owned and Operated
U
United Test and Balance
T jA\B 10440 Bradfool Rd. Unit C
Littleton, CO 80127
Information
Dear Customer
As we try to build our customer base and ensure your complete satisfaction on every project
United Test and Balance would like to extend a 180 Day warranty policy for every project The
terms of the warranty are listed below:
United Test and Balance does hereby warrant the before said completed project for a period of
180 Days from the date of the issued Certified Test and Balance Report. That said work shall
remain free from all defects in workmanship and material, and that it shall comply with all the
specific requirements of the Specifications and other Contract Documents governing the
Testing, Adjusting, and Balancing.
It is understood and agreed upon that in the event of defects and the necessary of making repairs,
the Owner and/or Contractor will immediately notify United Test and Balance in writing of its
conditions and shall give the contractor reasonable time, 30 days, in which to make said repairs.
If any person, firm, or corporation other than United Test and Balance has, since the completion
of the above work, performed or attempted to perform any repairs to the Mechanical Systems
then this warranty will become null and void This warranty does not cover any repairs made by
anyone other than United Test and Balance or one of its authorized representatives.
Thank you for the opportunity to work with you on this project and we look forward to
working with you in the future.
Sincerely,
,ire mean//
Jeremy Merrill
Owner
TAB.B. Certified Supervisor
Semper Fidelis
Veteran Owned and Operated
T 1/B United Test and Balance
Semper Fidelis
Veteran Owned and Operated
/A\ 10440 BrRd. Unit C
lon, C COW 127
Littleton,
Abbreviation Index
AC
Air Conditioning Unit
KW
Kilowatt
AHU
Air Handling Unit
IAT
Leaving Air Temperature
AMPorA
Ampere
LB
Pound
APD
Air Pressure Drop
LWT
Leaving Water Temperature
ATMOS
Amosphere
MA
Meed An
SHE
Brake Horsepower
MAX
Maximum
BTU
Bdusb Thermal Unit
MIN
Afinnourn
BTUH
BTU per Hour
MAU
Make -Up Air
CFM
Cubic Feet per Mmute
N/A
No Access
CHW
Chilled Water
Nom. ECT
Nominal Effrdency
CHWR
Chilled Water Return
OSA
Outside Air
CHWS
Chilled Water Supply
OD I ID
Outside Diameter I Inside Diameter
CT
Crashing Power
P
Pump
CUE
Cabinet Unit Hear
PD
Pressure Drop
CWR
Condenser Water Betum
PF
Power Factor
CWS
Condenser Water Supply
PFPB
Parallel Fan Power Box
DB
Dry Bulb(remperature)
PH
Phase
DEG or
Degree
PSI
Pounds per Square Inch
DP or AT
Differential Pressure
RA
Return elu
AT
Differential Temperature
RET
Return
(E)
Existing
RG
Return Guile
EA
Exhaust An
RH
Relative Humidity
FAT
Entering Air Tempentute
RPM
Revolutions per Moore
EP
Exhaust Fan
RTU
Boor Top Unit
ER
Exhaust Register
SA
Supply Alt
ERV
Energy Recovery Ventilator
SD
Supply Difficer
ESP
External Static Pressure
SP
Static Pressure
EWT
Entedvg WaterTempemmre
SF
Service Factor
°F
Fabreonat
SFPB
Series Fan Power Box
FPB
Fan Power Box
N. Ct.
Square Feet
FCU
Fur Cod Unit
T -IIT -21T-3
'Cumal 11 Tmwal 2 Temtinal3
FLA
Poll Load Amps
TEMP or °
Temperature
FPM
Feet per Minute
TSP
Total Static Pressure
FP.
Feet
T-Stat
Thermostat
HD.
Head
V
Volts
HP
Horsepower
VAV
Variable Air Volume
HWR
Hot Water Return
VFD
Variable Frequency Drive
HWS
Hot Water Supply
VP
Velocity Pressure
HZ
Herz Cycles per Second)
WE
Wet Bulb Temperature
IN,
Inches
W.C.
Water Column
NET
Kitchen Exhaust Fan
W.G.
Water Gauge
Semper Fidelis
Veteran Owned and Operated
United Test and Balance
United Test
and Balance
T\U,
(NI
I40 Rradfatri Rd. Unit C
XAX
Littleton.
CO 80127
Table Of Contents
PROJECT: "Ir Creek Crossing: Building 4
DAM: ")2021
LOCATION: Whattridge, CO
CONTACT:
PROJECT#: 21-2717
AUTHOR JeremyMenrill
Table Of Contents
1 Fan Coll ....................................................................................................................................................................
1
1.1 FCU-01 ...............................................................................................................................................................
1
1.2 FCU-02 ...............................................................................................................................................................
2
1.3 FCU-03 ...............................................................................................................................................................
3
1.4 FCU-04 ...............................................................................................................................................................
4
2 CCC Building 4 Mechanical Final.pdf ......................................................................................................................
5
United Test and Balance
u
TjAX
Fan Coil
PROJECT: Clear Creek Crossing: Building
LOCATION: Whesoodge, CO
PROJECT#: 21-2717
SYSTEMAINIT: FCU -01
United Test and Balance
IM40 Rrad(md Rd. Unit C
Littlausn. CIR 80127
Unll Menuhdurer
Filed Cis
Unit Model Number
26UC6
Unit seal Number
2101-12312
FCIIl Filter
F111er Type
Flbeglasa
Muir Qty -51
1
Muir 5'¢e-51
18xl8x1
Design ESP
Cocking SP Out
G 12in, we
Oullel-06
6D
Design Alrlbw
650 CFM
Actual ARM
775 CFM
Design Ou6Ne Air
113 CFM
Actual Ouseddi Air
121 CFM
Malar Vo16 T1-T2
210 Voft
Malar Armal T1
1.3 Amps
DATE: 13180/2021
CONTACT:
AUTHOR: Jeremy Merrill
Tested By: Brock Anderson
Date: &a0/2021
Malar ManuMCWrer
Motor HP
Motor Rated Von
Motor Phase
Motor FL Amps
Motor Ser o.Fat
Genteq
116 HP
206 Volts
1
17Amps
100
Carl i
200
1m Airflow
23S
%rr im O'.
116
Sheave Dens
Moloy Shavc MFG
UIIFgUrve
6D
200
169
Teat P es
ev,r,wc
Design ESP
Cocking SP Out
G 12in, we
LOQ[ FLU0l 81302021 Brock Mtlerson unit left Wred W high speed, low imsid was at 6l%
dreams.
n
Oull2
W11et Type
6D
Carl i
200
1m Airflow
23S
%rr im O'.
116
1n 23/ ew
119
Oulleb2
6D
200
169
92
231
116
Oullel-06
6D
1S0
230
163
166
120
Outlet -04
Su
100
ltg
V9
122
122
Totes:
I650
82)
12)
776
Its
N
United Test and Balance Page 1 of 7
u
TjAX
Fan Coil
PROJECT: Clear Creek Crossing: Building
LOCATION: Wheatddge, CO
PROJECT#: 21-2717
SYSTEMAINIT: FCU -02
United Test and Balance
IM40 FreA(md Rd. Unit C
Littlausn. CO 80129
Unll Menuhdurer
Filed Co
Unit Model Number
mum
Unit seal Number
210112306
FCIIAMAL Filter
F111er Type
Flbegiase
Muir Qty -51
1
Muir Sue -51
18xl8x1
Design ESP
Cocking SP Out
G 10in, we
uulew5
sD
Design Artkw
650 CFM
Actual Anil
789 CFM
real Ou6Ne Air
113 CFM
Actual ONsitle Air
109 CFM
Malar Vo16 T1-T2
209 Volts
Motor Amps T1
1.22 Amps
DATE: 6130/2021
CONTACT:
AUTHOR: Jeremy Merrill
Tested By: Brack Anderson
Date: &a0/2021
Malar Manusladi
Motor He
Motor Rated Von
Motor Phase
Motor FL Amps
Motor Ser o.Fat
Genteq
116 HP
206 Volts
1
17Amps
100
Design Aidbw
200
P 1m Ai dbw
'41
%PMim O'.
111
Sheave Dens
Moloy shave MFG
UIIFgOrve
sD
z00
Lib
Teat P es
ev,r,wc
Design ESP
Cocking SP Out
G 10in, we
LOQ[ FLU -32 811302021 Brock Antlerson unit left Wred W high speed, low spead was x165%
dreams.
n
oauewi
mum Type
sD
Design Aidbw
200
P 1m Ai dbw
'41
%PMim O'.
111
1n u6 ew
125
Gauew2
sD
z00
Lib
116
246
1z6
uulew5
sD
166
zo2
202
115
115
ouuew4
sD
150
146
99
134
123
Totes:
I650
808
121
769
Ise
United Test and Balance Page 2 of 7
u
TjAX
Fan Coil
PROJECT: Clear Creek Crossing: Building
LOCATION: Wheatddge, CO
PROJECT#: 21-2717
SYSTEMAINIT: FCU -03
United Test and Balance
IM40 Rrad(m0 Rd. Unit C
Littleton. CO 80129
Unll Manufacturer
Filed Co
Un11 Model Number
26UC6
Unit seal Number
2101-12313
FClUl Filter
F111er Type
Fiberglass
Muir Qty -51
1
Muir 5'¢e-51
18xl8x1
Design ESP
Cooling SP Out
041n.wc
me 10,n wC
Ou11e1-03
30
Design AlMaw
650 CFM
amoral ARM
546 CFM
Design Ou6Ne Air
113 CFM
Actual ONsitle Air
103 CFM
Mail Vo16 T1-T2
205 Vo16
Mail Armed T1
1.03 Amps
DATE: NI30=21
CONTACT:
AUTHOR: Jeremy Merrill
Tested By: Brock Anderson
Date: &30/2021
Motor Manufacturer
Motor He
Motor Rated Von
Motor Phase
Motor FL Amps
Motor SA.1111n Fct,,r
Genleq
116 HP
206 Volts
1
17Amps
1 00
200
131
6
Sheave One
Mo10r Shavc MFG
UIIFgOrve
30
200
UP
Teat Press
Design ESP
Cooling SP Out
041n.wc
me 10,n wC
Systematist
Ou11e1-01
ounce ryw
20
200
131
6
198
56 Final Dun.
99
Outlet -02
30
200
UP
87
200
1-0
Ou11e1-03
30
75
143
191
72
96
Outlet -04
30
/0
126
158
]8
101
Tee18:
550
574
104
548
99
N
United Test and Balance Page 3 of 7
u
TjAX
Fan Coil
PROJECT: Clear Creek Crossing: Building
LOCATION: Wheatridge, CO
PROJECT#: 21-2]1]
SYSTEMAINIT: FCU -O#
United Test and Balance
IM40 Bradford Rd. Unit C
Littlausn. CO 80129
Unit Menuhdurer
Filed Co
Unit Model Number
mum
Unit sell Number
2101-IM16
FCU,0 WAIr Filter
Filter Type
Howl
Filter Qty -51
1
Muir 5'¢e-51
18xl8x1
Design ESP
Cocking SP Out
X000in, we
Oudot-03
6D
Design Arnow
650 CFM
Actual Airflow
725 CFM
Design Ou6Ne Air
113 CFM
Actual ONsitle Air
118 CFM
Malar Vol%T1-T2
208 Voft
Malar Armal T1
1.4 Amps
DATE: 13180/2021
CONTACT:
AUTHOR: Jeremy Merrill
Tested By: Brock Anderson
Date: &a0/2021
Malar ManuMcWrer
Motor HP
Motor Rated Von
Motor Phase
Motor FL Amps
Motor Ser o.Fat
Genteq
116 HP
206 Volts
1
17Amps
190
0.upn
200
im Airflow
278
%PrNim O'.
149
Sheave Dens
Moloy Shavc MFG
UIIFgOrve
I
200
191
Teat P es
ev,r,wc
Design ESP
Cocking SP Out
X000in, we
LOQ[ FCO(34 fl1302021 Brock Anderson unit left Wred W high speed, low speed was at ]8%
a deli n
Outlebi
thin Type
SD
0.upn
200
im Airflow
278
%PrNim O'.
149
�n 216 ew
106
Oulleb2
I
200
191
98
224
112
Oudot-03
6D
260
26tl
104
286
114
Toops:
550
Toe
115
7Z5
112
United Test and Balance Page 4 o17
coil
IR Im
arovrov m�n�
Page 5 of 7
ma rvau.sw+a.rn �w..+ �r.
�'® wa`rw nnrwew. a. rau
gr
m��auapicaw.xanrs�+L+'�.s �i�}`rvu,+�+
2012 INC, 2012 IECC
MECHANICAL PLAIN INDEX
a
Z_
IN
V/
U
Y
W
W
w
U
W
J
U
Y
O
O
J
r
O
i
s
z�w
so
00
w
no
0
z z
w
c
zICU
i
w 3
v w ax
Iv� Y
coil
IR Im
arovrov m�n�
Page 5 of 7
ma rvau.sw+a.rn �w..+ �r.
�'® wa`rw nnrwew. a. rau
gr
m��auapicaw.xanrs�+L+'�.s �i�}`rvu,+�+
2012 INC, 2012 IECC
MECHANICAL PLAIN INDEX
a
Z_
IN
V/
U
Y
W
W
w
U
W
J
U
Y
O
O
J
r
O
i
s
z�w
so
00
w
no
0
z z
w
c
zICU
i
w 3
HOT WATER o%FAN COIL DETAIL s
coil
IR Im
arovrov m�n�
Page 5 of 7
ma rvau.sw+a.rn �w..+ �r.
�'® wa`rw nnrwew. a. rau
gr
m��auapicaw.xanrs�+L+'�.s �i�}`rvu,+�+
2012 INC, 2012 IECC
MECHANICAL PLAIN INDEX
a
Z_
IN
V/
U
Y
W
W
w
U
W
J
U
Y
O
O
J
r
O
i
s
z�w
so
00
w
no
0
z z
w
c
zICU
i
w 3
r —
ra
a>. I' 7�14SL a. 1� r V��i.a�� •
1Ti' 0.i' a■
4 • _ 1 n
LU zLU 20mom
UJI
•
ow
•
•
"WW. �.
4050 Clem Creek Dr
201902580
buildina ONE consultina. Ilc
August 24, 2021
Mr. Tom Harris
Evergreen
1873 South Bellaire Street, Suite 1200
Denver, CO 80222
RE: Building Envelope Consulting Services
Outlook Clear Creek
W heatridge, Colorado
Project Number 19 -1205 -CC
Dear Mr. Harris
Building One reviewed the Building Envelope at the Outlook Clear Creek property, specifically at the 4050
Clear Creek Drive address. The weather resistive barrier was observed at all exterior wall assemblies.
Building One initially noted some inconsistencies, but it appears that all our concerns have been addressed.
It is our understanding that the exterior wall assemblies are in general conformance with the construction
documents and industry standards.
If you have any questions, please do not hesitate to call.
Sincerely,
Building One Consulting, LLC
Chad Stinnett, RA
Associate
ViaEmail. Tom Harris'. tharrisadevme.com
denver I boston
3190 s. wadsworth blvd., suite 230 1 lakewood, co 80227 1 303.986.1400
COLORADO
^Yi_C Lebmatory ServiasDivision
w�anmrmdwmewauc owanmrm
4050 Clear Creek Dr
201902580
Colorado Department of Public Health and Environment
8100 Lowry Blvd. Denver, CO 80230 Tel: 303-692-3090 Fax: 303-344-9989
Analysis Report
Workorder: 2358155 Environmental Microbiology, Wa
Client:
PLATTE RIVER PLUMBING
Profile:
Environmental Microbiology, Water
Sampled By:
MEGAN
Sample Summary
Report To: LLOYD DECKER
PLATTE RIVER PLUMBING
PO BOX 640
Henderson, CO 80640
Analyes
Lab ID Sample ID Sample Type Method Date Collected Date Received Reported
2101552046 223-60 Water P/ttal Coliform and E. coli 08/11/2021 12:45 08/11/2021 14:11 2
Y /1
E Travant , hD
Scientific Director
Note: The samples were tested as received from the customer and the
results in this report relate only to the samples tested.
MRL -Minimum Reporting Limit BDL -Below Detection Limit, —Comment applied
WL -Maximum Contaminant Limit per EPA regulations;
mgh - milligrams per liter(ppm), ugh micrograms per l iter (ppb)
Report ID: 3879292
Thursday, August 12, 2021 4:31:04 PM
Page 1 of 2
PO�REY BY
HORIZON'
COLORADO
Colorado Department of Public Health and Environment
8100 Lowry Blvd. Denver, CO 80230 Tel: 303-692-3090 Fax: 303-344-9989
Analysis Report
Workorder: 2358155 Environmental Microbiology, Wa
Sample Results
Lab ID:
2101552046
Sample ID: 223-60 Sample Type: Water
Date Collected:
08/112021 12:45
Collection Site: 4050 CLEAR CREEK DR WHEAT RIDGE CO 80401
Date Received:
08/112021 14:11
Site Description:
Description:
4050 CLEAR CREEK DR
WHEAT RIDGE CO 80401
Parameter Results Units MRL MCL DF Prepared Analyzed Qual
EPA 92238 (Total Coliform and E. coli P/A)
COLIFORM P/A ABSENT 1 08/12/2021 13:29 08/12/2021 13:29
A COLIFORM P/A result of ABSENT" indicates a microbiologically safe sample. Coliform was absent or less than one(o l) Coliform per 100 ml.
E. COLI P/A ABSENT 1 08/12/2021 13:29 08/12/2021 13:29
An E. COLI P/A result of "ABSENT" indicates that E. coli was NOT DETECTED.
Additional Information
SDWIS Data
Free Chlorine
Total Chlorine
Temperature at Collection:
Temperature at Receipt:
Water Type:
Report ID: 3879292
Thursday, August 12, 2021 4:31:04 PM
Page 2 of 2
0
LAV 4-107
MRL -Minimum Reporting Limit BDL -Below Detection Limit, —Comment applied
WL -Maximum Contaminant Limit per EPA regulations;
mgh- mi l ligrams per liter (ppm) ugh micrograms per l iter (ppb)
PO�REY BY
HORIZON'
4050 Clear Creek Dr
201902580
Bone Dry Mechanical LLC
JERRY PETTIBON
720.436.2619
15215 E. OHIO AVE
Aurora, CO 80012
Assembly Serial #
Test Date /Time
Tester Certification #- `
Assembly Test Results �KPaSS ❑*Fail
Udder Suspension - Proeess IMmediately
Denver Water Backflow Assembly Test & Maintenance Reoort (nlea.sa print with Rl 0r1I( 1 PT•r;:D1%1rr,
Testing Company: Submit by e-mail (preferred) to CrossConnectionControl@denverwater.org,
type "Backflow Test Reports" in the subject line OR submit by Fax to (303) 794-8325.
* FAILED test results must be reported to Denver Water within 24 hours of failure at (303) 628-5969.
i r
Facility Name:
`
Meter #:
0
Facility Address: ,�-
City: jti _Oe :, 6
a
Contact Person: j
�G?1� •
Make: • � ,-- Z,$ Model: ` G
Phone:
-
Type: V9-RPe( ❑ DC Cl PVB [--]Air Gap
Type of Use Protection
Orientation
Size: Date Installed: -�9
Domestic VContainment
Inlet Outlet
N
ew ❑Existing
❑ Fire ❑ Glycol ❑ Containment
by Isolation 4!�(_ Horizontal
a
Previous Assembly #: -ti uA,
❑ Irrigation ❑ Isolation
❑ Vertical Up ❑
Location:-&� �Z,�
❑ Recycled
❑ Vertical Down ❑
Line Initial Test Results
PSI: Tightness Differential
Repairs
Approved: Y lig N ❑
Re -Test Results
Check Valve #1 ❑ Leak J
Tightness Differential
❑ Leak
(RP, DC, PVB) Night
Check Valve #2 ❑Leak � �
(RP, DC) ight
❑ Tight
❑Leak
U
El Tight
m
Relief Valve
(RP) c3
Buffer L
(RP)
Air Inlet
m
(PVB)
'2
Shutoff Valve #1: VIZight ❑ Leaking ❑ Replaced Shutoff Valve #2: Night ElLeaking 11 Replaced
Backpressure: El Yes o Test Procedure: ❑ ABPA:
ASSE:
Comments:
Q
Alarm Company/Fire Department: LA
Z
Person Notified:
Contacted By:
z
Turn Off Date/Time:
-----------------
Test Kit Make _ $ '(�I"
Turn On Date/Time:
Model: � - I
iT
Serial #: ,5-
Last Calibration Date:
P j
Tester certifies this assembly has been tested with the above listed pro edure and verifies the isolation valves were returned to Pre-test orientation.
Testing Company: � �. Cr��
y�
Tester Name: J i iv
Phone_
a,(:� _313Z _ a
Signature: yJ
Certificate Expiration Date:
Testing Company: Submit by e-mail (preferred) to CrossConnectionControl@denverwater.org,
type "Backflow Test Reports" in the subject line OR submit by Fax to (303) 794-8325.
* FAILED test results must be reported to Denver Water within 24 hours of failure at (303) 628-5969.
The City of Wheat Ridge
7500 W. 29th Avenue, Wheat Ridge, CO 80033
Third Party Form Check List
Property Address
Permit Number
Permit Issued Date
Owner Information
Property Owner Information
Property Owner Address
Inspection Company
Inspector Name
Inspector Contact info.
Inspector Statement and Acknowledgement
* I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs
that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept.
* I hearby acknowledge the roofing system for the referenced building has been inspected
and found to be in compliance with the minimum requirements of the 2012 IRC and 2012
IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's
recommendations. an s ecifications.
Inspector: Date: /'Z �2 p
Property Owner Statement of Acknowledgement
*1 hearby acknowledge that I am the owner of the building referenced above and I give
my consent for the listed third -party inspection company to perform my roof inspection
in lieu of the City of Wheat Ridge Building Division inspection.
Propery Owner/Agent:
Date:
This original document must be submitted to the Chief Building Official within seven days of
the final inspection.
Email to permits@ci.wheatridge.co.us
Please add note to reverse side
The City of Wheat Ridge
Inspection Check List notes
Final Roof
PROPERTY ADDRESS: ° olo Ckof Ic_ A, (L`
❑ N/A
Roof Inspection
❑ Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
❑ N/A
❑ Pass
❑ Fail
Above roof insulation R-25
N/A
❑ Pass
❑ Fail
Structural roof components
N/A
❑ Pass
❑ Fail
Verify that no more than 2 layers of shingles exist
❑ N/A
® Pass
❑ Fail
Flashing for roof and walls
FA Pass
❑ Fail
If new sheathing is installed verify that it is listed in the
permit description (Valuation must be adjusted)
[0 N/A
❑ Pass
❑ Fail
Verify sheathing nail pattern (See Policy & Procedures)
❑ N/A
N Pass
❑ Fail
Crickets and saddles where needed
❑ N/A
14 Pass
❑ Fail
Verify B vent must have boot same gauge as pipe
❑ N/A]
Pass
❑ Fail
Verify vent caps
❑ N/A
Pass
❑ Fail
Verify no flashings are damaged or rusted
❑ N/A
9 Pass
❑ Fail
Step flashing shall be min. of 4x4 piece per shingle
❑ N/A
® Pass
❑ Fail
Verify scuppers allow for proper drainage
❑ N/A
Pass
❑ Fail
Ice and water shield 2' in heated wall spaces
❑ N/A
Pass
❑ Fail
Underlayments must follow 2012 IRC / 2012 IBC
❑ N/A
R Pass
❑ Fail
Verify roof slope for proper drainage
❑ N/A
Pass
❑ Fail
Dripedge shall have min of 2" overlap
❑ N/A
Pass
❑ Fail
Dripedge should extend down min 2" past roof deck
❑ N/A
Pass
❑ Fail
Dripedge shall be mechanicaly fastened 12" OC
® N/A
❑ Pass
❑ Fail
90 LB roll roofing shall not be applied to roof slopes
less than 2:12 slope; Exception: detached garages,
patios, carports, open on three sides with min. slope of
1:12
❑ N/A
� Pass
❑ Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
❑ N/A
[k] Pass
❑ Fail
Above roof insulation R-25
❑ N/A
[ Pass
❑ Fail
Below roof residential R-38
❑ N/A
Pass
❑ Fail
Below roof commercial R-32
❑ N/A
[ Pass
❑ Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
must be installed in accordance with the manufacturer's
specifications - Must have manufacturer's letter of
warranty with the address on the letter for final inspection
Metal Roof Shingles
Requirements
N/A
❑ Pass
❑ Fail
Metal roof shingles shall not be installed on slope less
3.12
N/A
❑ Pass
❑ Fail
Metal valley flashing shall be the same material as roof
N/A
❑ Pass
❑ Fail
Metal valley flashing shall extend a min of 8" from the
centerline with a min. of 3/4 " high splash diverter
rib built-in at the flow line with sections overlapping a
a min. of 4"
Tile Roofs Requirements
N/A
❑ Pass
❑ Fail
Clay and concrete tile shall have a min. 2-1/2:12 slope
Slopes 4:12 and under require double underlayment
The City of Wheat Ridge
Inspection Check List notes
Final Roof
Notes
Company Name:
Inspector signature:
Date of Inspection: 2
The City of Wheat Ridge
7500 W. 29th Avenue, Wheat Ridge, CO 80033
Third Party Form Check List
Please add note to reverse side
The City of Wheat Ridge
Inspection Check List notes
Mid -Roof
PROPERTY ADDRESS c/5C) C'(
Roof Inspection
❑ N/A
❑ Pass
❑ Fail
N/A
❑ Pass
❑ Fail
Structural roof components
N/A
❑ Pass
❑ Fail
Verify that no more than 2 layers of shingles exist
FkJ N/A
❑ Pass
❑ Fail
Flashing for roof and walls
❑ Pass
❑ Fail
If new sheathing is installed verify that it is listed in the
permit description (Valuation must be adjusted)
Q N/A
❑ Pass
❑ Fail
Verify sheathing nail pattern (See Policy & Procedures)
❑ N/A
❑ Pass
❑ Fail
Crickets and saddles where needed
N/A
❑ Pass
❑ Fail
Verify B vent must have boot same gauge as pipe
FA N/A
❑ Pass
❑ Fail
Verify vent caps
❑ N/A
Pass
❑ Fail
Verify no flashings are damaged or rusted
[ N/A
❑ Pass
❑ Fail
Step flashing shall be min. of 4x4 piece per shingle
❑ N/A
® Pass
❑ Fail
Verify scuppers allow for proper drainage
❑ N/A
In Pass
❑ Fail
Ice and water shield 2' in heated wall spaces
❑ N/A
[. Pass
❑ Fail
Underlayments must follow 2012 IRC / 2012 IBC
❑ N/Ar�71
Pass
❑ Fail
Verify roof slope for proper drainage
F-1 N/A
IJ Pass
❑ Fail
Dripedge shall have min of 2" overlap
❑ N/A
Pass
❑ Fail
Dripedge should extend down min 2" past roof deck
❑ N/A
4t"I Pass
❑ Fail
Dripedge shall be mechanicaly fastened 12" OC
T N/A
❑ Pass
❑ Fail
90 LB roll roofing shall not be applied to roof slopes
less than 2:12 slope: Exception, detached garages,
patios, carports, open on three sides with min. slope of
1:12
❑ N/A
14 Pass
❑ Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
❑ N/A
VI Pass
❑ Fail
Above roof insulation R-25
❑ N/A
Pass
❑ Fail
Below roof residential R-38
❑ N/A
13 Pass
❑ Fail
Below roof commercial R-32
❑ N/A
Q Pass
❑ Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
must be installed in accordance with the manufacturers
specifications- Must have manufactures letter of
warranty with the address on the letter for final inspection
Metal Roof Shingles
Requirements
N/A
❑ Pass
❑ Fail
Metal roof shingles shall not be installed on slope less
3:12
N/A
❑ Pass
❑ Fail
Metal valley flashing shall be the same material as roof
N/A
❑ Pass
❑ Fail
Metal valley flashing shall extend a min of 8" from the
centerline with a min. of 3/4 " high splash diverter
rib built-in at the flow line with sections overlapping a
a min. of 4"
Tile Roofs Requirements
N/A
❑ Pass
❑ Fail
Clay and concrete tile shall have a min. 2-1/2:12 slope
Slopes 4.12 and under require double underlayment
The City of Wheat Ridge
Inspection Check List notes
Mid -Roof
Notes
Company Name: (3uLtD n9(-, 0 LLJ C zNS"L I,"17,#
Inspector signature:
Date of Inspection:20
July 20, 2021
Evergreen Development
1873 South Bellaire Street, Suite 1200
Denver, CO 80222
Attn: Evergreen Development
Re: Compliance Letter for Special Inspections
Outlook Clear Creek, Permit No.: 201902580
4050 Clear Creek Drive, Building 4
Wheat Ridge, CO
CGG Project Noe. 19.23.225
Cole Garner f-AmAt technical
1070 W. 124 t" Ave, Ste. 300
Westminster, C 111111111111) 802 34
303.996.2999
At your request, Cole Garner Geotechnical (CGG) was retained to provide construction special inspection
and materials testing for the above-named project. Observation and special inspection services were
performed as scheduled by the contractor during the construction of the following elements:
Fairestoppoing - periodic visual special inspection of membrane penetrations to verify adherence
with manufacturer recommendations for UL rating
Wood Framing -visual inspection of shear and gravity systems including member size, grade and
orientation including hardware and fasteners
The results of our special inspections were noted to comply with the approved project plans,
specifications and relevant sections of the International Building Code.
We trust that the information presented herein satisfies your present needs.
Sincerely,
irner Geotechnica
Thomas C. Cole, P.E.
Principal
�DOLlCtdp<(��4
'%ON
v e o 0,6
� �
co
o 42518 oe,
Ole 20121 •: w�c,
SS/ONAI. �
4050 Clear Crk Dr
201902580
nae In Street
canmer«Gq.co real
ram, •¢303 3 F `pa"recnnem
303783.01211
moria.
earl Cntlga,Ii� heEmail SeM[ePN}OFrc
pn[com
Assembly Serial 111 13312
Test Date / Time 7.15.21
Tester Certification 1116-784
ssembly Test Results ® Pass ❑ Fail
El Under Suspension- Process Immediately
pkasepnnt with BLOCK LETTERING)
E
Water Supplier: Consolidated District:
Meter#:
Facility Address: 4050 Clear Creek Dr bldg lW
City. Lakewood ST: CO zip: 80401
Contact Person:
Phone:
Make: Ames Model: DernAer40GX
Type of Use Protection Orientation
Type: to RP o DC o PVB o Air Gap
sa
S1ze'.4" Date Installed7/2021
oOomestic mCortamment IBlel Outlet
m New nExisling
mFee oGlycol OCortamment by Isolation m Horizontal m
Q
Previous Assembly#:
01milation olsolation o Vertical up D
oRecycled o Vertical Down o
Location: Fire Riser Room
Approved: V m No
Line
85
Intlial Test
Results
Repairs
Re -Teat Results
Tghmeas
Differential
Tightness
Differential
PSI:
Check Valve#1
TIxi
oLeak
(RP, DC,PVB)
¢Tight
9'4
oTght
Check Valve#2
DLllas
oLeak
(RP, DC)
¢Tight
2'4
0l
Relief Valve
(RP)
3.2
F
Buffer
s
(RP)
6.2
Air Inlet
(PVB)
Shutoff Valve F: ®Tight oLeaking
0Replacetl
lShutoffVaIml mTight otseaking oReplacetl
Backpressure: oyes ONO Teal
Procedure: mABPA: PASSE:
Comments:
`=
All Company/Fire Department:
DFS CertHicatlon#:
5
Person Notified:
Contacted! By:
zz
Tum Of DatelTime:
Tum On Oseenrane:
r
Test Kit Make: Midwest
Model: 845
c
Serial#: 02142752
Last Calibration Dale: 4/19121
Tearer[ware:for, aaaembryties been eased wiOMeabove
rakupswedeead aral Me sweet views mai, warrant roinstead ouseg4on.
e
Testing Canpany 1120FIrePreteNoglno.
8
Tester Name: Manaus McCracken
Phl (303) 761-P55
Signature:
Cediticate Expiration Date: 912221
Testing Con pano Submit bye -mall (preferred) to Cr�aCcnrwdlmContrd�emenreb.om.
type heart Test Relars' n Me Object Ins OR means by Pox bEver) }968325.
'FAILED test resut must be reported to Denver Water at Mn 24 hours dhedure at (303) 626-509,
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
InspectionLi
Type
:&Permit rte+► #
i
Number:
�,►
❑ No one available for inspection: Ti
Re -Inspection required: YesN
When corrections are complete,
City of Wheat Ridge
Multi -Family - New PERMIT - 201902580
PERMIT NO: 201902580 ISSUED: 02/19/2020
JOB ADDRESS: 4050 Clear Creek Dr EXPIRES: 08/20/2021
JOB DESCRIPTION: Clear Creek Crossing - Four story building with tuck -under garages, 37
units - 44,054 sq ft total
*** CONTACTS ***
OWNER
EVERGREEN CLEAR
CREEK CROSSING
GC (303) 757-0401
Ron Wolford
180393 Nexus Builders
LLC
SUB (303)795-6116
MONTE LOSAW
160078 LOSAW ELECTRIC
INC.
SUB (303)288-2308
WILLIUAM C COFFEY III
110081 PLATTE RIVER PLUMBING INC.
SUB (720)373-4378
CORY JOHNSTON
190344 CBA MECHANICAL
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
UA / Unassigned
BLOCK/LOT#:
/
*** FEE SUMMARY ***
ESTIMATED PROJECT VALUATION:5,387,200.00
FEES
Total Valuation
0.00
Plan Review Fee
120.00
Use Tax
113,131.20
Permit Fee
24,452.85
Engin. Review Fee
100.00
** TOTAL **
137, 804.05
*** COMMENTS ***
*** CONDITIONS ***
Approval from presiding fire department required prior to final building inspection
sign -off.
All roughs to be done at Framing Inspection.
No C.O. may be issued until public improvements are complete as identified in the
Subdivision Improvement Agreement.
All landscaping shall be installed in accordance with the approved landscape plan (Case No.
WZ-19-01) prior to C.O. and pursuant to the phasing identified in the Subdivision
Improvement Agreement. Per the SIA, installation of landscaping, street trees, and
irrigation is not required prior to Certificate of Occupancy if issuance of the C.O. occurs
outside of the planting season, generally October to June.
Architectural elevations shall match the approved master plan permit.
1* � 4 41'
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City of Wheat Ridge
Multi -Family - New PERMIT - 201902580
201902580 ISSUED: 02/19/2020
4050 Clear Creek Dr EXPIRES: 08/20/2021
Clear Creek Crossing - Four story building with tuck -under garages, 37
units - 44,054 sq ft total
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
�pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
02/19/2020
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
♦�
City of
Wheatldge
COMMUNITY DEVELOPMENT
CityofWheat Ridge Municipal Building 7500 W. 20 Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929
Permit Extension Request Form
Permits expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in
writing and received prior to the date of expiration. An extension of no more than 180 days may be granted at the
discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee.
Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not
guaranteed. Please complete this form in its entirety and submit to the Building Division at
permits(cilci.wheahidge.co.us or fax to 303-237-8929.
Party requesting permit extension: Evergreen Clear Creek Crossing
Permit # 201902580
Property Address: 4050 Clear Creek Dr.
Phone# 720-272-8725 Email Address: adeckert@evgre.com
Reason for extension request: Delayed construction start
Number of days requested: 10/30/2021
Printed Name: Amy Deckert Signature:_z"—' Date: 02/22/2021
For office use only
This request has been: XI Approved ❑ Denied Extended =it 8/20/2021
Approved by: 7;L - D Daze: 2/22/2021
www.ci.whealridgaco.us
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
.. � .. - �► •rte � # ,,��- ., ,�,,,:.
❑ No one available for inspection: Tir ' `-.r/I�PM
Re -Inspection required: Ye
When corrections have been made, se�dule for re -inspection online at:
http://www. ci. wheatridge. co. usfinsp6(cti
Dat
K4��L__ I ni, /
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
❑ No one available for inspection: Ti
Re -Inspection required: Ye$L
*V
nr
x
44" City of Wheat Ridge
_A� Commercial Low Voltage PERMIT - 202002605
PERMIT NO: 202002605 ISSUED: 12/16/2020
JOB ADDRESS: 4050 Clear Creek Dr EXPIRES: 12/16/2021
JOB DESCRIPTION: Clear Creek Crossing - Installation of new fire alarm system - 44,939 sq ft
total
Fees paid on Permit No. 202002084
*** CONTACTS ***
OWNER EVERGREEN CLEAR CREEK CROSSING
SUB (303)973-7412 TODD WAGNER 202244 VULCAN FIRE & SECURITY
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 0.00
FEES
** TOTAL ** 0.00
*** COMMENTS ***
*** CONDITIONS ***
All work shall comply 2018 International Codes, 2020 NEC (if applicable), and ordinances
adopted by the City of Wheat Ridge. Work is subject to field inspections.
I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications,
applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
From: no-reolv(alci.wheatridae.m. us
To: CommDev Pets
Subject: Online Form Submittal: General Permit Application
Date: Tuesday, December 15, 2020 3:11:06 PM
General Permit Application
This application is exclusively for Scopes of Work that do not already have a
specific form.
YOU MUST ATTACH AN ELECTRONIC PAYMENT FORM IN ORDER FOR THE
PERMIT TO BE PROCESSED.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Is the property
Residential or
Commercial?
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
CONTACT INFORMATION
Residential
4050 Clear Creek Dr
Evergreen Development
(303)757-0401
Field not completed.
Submitting General Vulcan Fire & Security
Contractor or Architect
Contractor's License
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
202244
Contract Phone (303)973-7412
Number (enter WITH
dashes, eg 303-123-
4567)
Contact Email Address permits@vulcanfiresecurity.com
Retype Contact Email permits@vulcanfiresecurity.com
Address
01:K161CiI91 ffl0N]ayOLib]N:/
Detailed Scope of
Installation of new fire alarm system into multi family housing
Work - Provide a
w/elevator recall and sprinkler monitoring
detailed description of
work including
mechanical, electrical,
plumbing work
occurring,
adding/removing walls,
etc.
Square footage of
44939
scope of work
Location of work
Inside Building
(backyard, on roof, etc)
Project Value (contract
Paid under permit 202002084
value or cost of ALL
materials and labor)
Upload Engineer letter, Field not completed.
other documents on 8
1/2" x 11 "
Upload Asbestos Field not completed.
Report if triggler level is
met per CDPHE
regulation.
Upload 20200513130758 00400 Q - ... i
17" or larger
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Person Applying for Robert Jones
Permit
Email not displaying correctly? View it in your browser.
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address:`
Permit Number:.
❑ No one available for inspection: Ti _ M/PM
Re -Inspection required: Yes
When corrections have been
http✓/www. cL wheatridge, co, u
Dat : . ay_ fins
schedule for re -inspection online at:
3OIION SIHI-gAOW3bl ION 00
:aoloadsul:a}�a
uoijoadsu!lsn-oo-a6ppleayM p Ntmmll-d;;y
:;e augluo uo►;oadsui-ar ao{ a/npayos `apew uaaq aneq suoijoaaaoo uayM,
ON saA :paainbaa uoiloadsul-aH
WdMV auail :uoijoadsui aol algelil3na auo oN;7
Q' lq -- o 117/ bcP �a7
'y
f. V
Ir
/ � r :.iagwnN Iluaaad
7�5,,?/i :ssaippd qof
�r fit• s. :adAl uol}oadsul
331ION N01103dSNI
a3wo 958Z -9£Z (£0£)
uolsinla uoiloadsul 6uiplln8
39ala IV3HM d0 A113 ° r 1
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number: j
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Yes
When corrections have been mad sche le for re -i line at:
http✓/www.ci.wheatridge.co.uslins ection
If
♦ A i CITY OF WHEAT RIDGE;
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address: ear";
Permit Number:
❑ No one available for inspection: Time �;: '- . - /_AM/PM
Re -Inspection required: Yes .�o1)
When corrections have been made, schedule for re -inspection online at.
http://www.ci.wheatridgecouslinspection
Date: ' `':. Inspector: �fz
DO NOT REMOVE VE THIS NOTICE
August 26, 2020
Evergreen Development
1873 South Bellaire Street, Suite 1200
Denver, CO 80222
Attn: Dan Scholtz
arner ^- techniccb
1070
W. 124 t" Ave, Ste. 300
Westminster, CO 80234
303.996.2999
Re: Compliance Letter for Special Inspection and Materials Tests
Outlook Clear Creek, Permit No.: 201902580
4050 Clear Creek Drive, Building 4
Wheat Ridge, CO
CG Project Noe. 19.23.225
IPermit # 201902580
14050 Clear Creek Drive
At your request,, Cole Garner Geotechnical (CGG) was retained to provide construction observations and
materials testing for the above-named project. Observation and special inspection services were performed as
scheduled by the contractor during the construction of the following elements:
Excavation Observation -observation prior to foundation construction to verify conformance to with
geotechnical report
Reinforced Concrete -inspection of reinforcing steel and concrete placement for foundations and slabs
Concrete Encased Grounding Rod - inspection of placement of Ufer ground rod in foundation
Post -Tensioned Concrete - inspection of tendon layout,, concrete placement operations
subsequent stressing operations
Structural Masonry - visual inspection of reinforcing steel and grout placement
In addition, materials tests were periodically conducted for the following elements:
Concrete - temperature, slump, air content,, unit weight and compressive strength
Grout - compressive strength
and
The results of our materials tests and special inspections were noted to comply with the approved project plans,
specifications and relevant sections of the International Building Code.
We trust that the information presented herein satisfies your present needs.
Sincerely,
..... .r Geotechnical
Thomas C. Cole, P.E.
Principal
DO P�Risr�'ION
t&ewo
wi 4251 0.
-o
'0 8�2 20goo 00
/ON A)kPF-ffi ENS\
_M�
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number:
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online at:
http://www. ci. wheatridge. co. uslinspection
Date: Inspector:
DO NOT REMOVE THIS NOTICE
D
(n
70
CD
0
O
7
s *
M
G
eD
Z
:
O
®
7
C)CD
cn
Cb =
CO)
�.
CT
CD
n
CD
O
Q
0.
m
CD
CDD "�
CD
n
0
0
o
0CD
�=
Z
O
Z
3
o
CD
CbCb
0
0
m
0
o
D
CDZ
L $
g 0
Z > O
r Q
CD CD
N CD
Z
cn
4:z
��
q
� /
Z
Z
O
m
Clear Creek Crossing
On •
4050 Clear Creek Drive
Permit No. 2019 02580
y-/-7--�>U e, 4
ANCHOR
ENGINEERING
STRUCTURAL ENGINEERS
June 1, 2020
Kephart Architects
Attn: Janet Grady
2555 Walnut Street
Denver, CO 80205
RE: Outlook Clear Creek
Building 4
4050 Clear Creek Drive
Wheat Ridge, CO 80215
Dear Mrs. Grady,
Per our contract, our office reviewed tendon elongation reports dated May 13, 2020 (Revised May 26, 2020) and
May 30, 2020 provided by Cole Garner Geotechnical for the above referenced project. The reports indicate that
the special inspector from Cole Garner observed as the tendons were stressed using the following equipment:
Ram No. PT Puller #206 & Jack & Associates #302
Gauge No. #206 McDaniels, 10,000 PSI, 4" & #302 McDaniel, 10,000 PSI, 4"
Pump No. SPX Power Team, #206, S/N 371136 & Enerpac, #302, S/N 1403
The equipment #206 was last calibrated on February 14, 2020 and equipment #302 was last calibrated on May 15,
2020. The corresponding stressing gauge pressure is 5,385 & 5,460 pounds per square inch respectively when
applying 33 kips of tension to the tendon. A copy of the associated calibration curve was provided to our office
for our records and review.
Reports dated May 13, 2020 (Revised May 26, 2020) was for all of the tendons in the pour. After review of this
report tendons #6A, #7A, #713, #7C, #17A, #23A, #23B, #23C, #25A, #25B, #28A, #29A, #29B, #30A, #30B,
#31A, #31B, #34A, #41B, #43A, #43B, #46A, #49A, #58A, #7113, #73A, #76B, #77A, #78A, #78B, #80A, #80B,
#81 A, #81 B, #82A, #82B & #83A did not meet the code allowed minus 10% deviation and needs to be re -
stressed. Report dated May 30, 2020 was the elongation report for the tendons that needed to be re -stressed.
Based on our review of the stressing records, calibration curve, PTI allowances of +/- 1/4" elongations for short
tendons, and the knowledge of the measurements taken to the nearest 1/8", it is our opinion that all the tendons
included in these reports have been adequately stressed and can be burnt off to a distance of 3/4" inside the
exterior surface of the concrete. Stressing pockets should be packed with grout as outlined in the contract
documents.
If you have any questions or need additional information, please contact our office.
Sincerely,
Anchor Engineering, Inc.
Charles D. Petzir, P.E.
Project Engineer
2535 17T" STREET, DENVER, CO 80211 ❖ 303-783-4797 s 303-830-9133 Fax •:
-/-7 -Fv k
ANCHOR
ENGINEERING
STRUCTURAL ENGINEERS
May 27, 2020
Kephart Architects
Attn: Janet Grady
2555 Walnut Street
Denver, CO 80205
RE: Outlook Clear Creek
Building 4
4050 Clear Creek Drive
Wheat Ridge, CO 80215
Dear Mrs. Grady,
Per our contract, our office reviewed tendon elongation report dated May 13, 2020 (Revised May 26,
2020) provided by Cole Garner Geotechnical for the above referenced project. The reports indicate that
the special inspector from Cole Garner observed as the tendons were stressed using the following
equipment:
Ram No. PT Puller #206
Gauge No. #206 McDaniels, 10,000 PSI, 4"
Pump No. SPX Power Team, #206, S/N 371136
The equipment was last calibrated on February 14, 2020. The corresponding stressing gauge pressure is
5,385 pounds per square inch when applying 33 kips of tension to the tendon. A copy of the associated
calibration curve was provided to our office for our records and review.
Based on our review of the stressing records tendons #6A, #7A, #713, #7C, #17A, #23A, #23B, #23C,
#25A, #25B, #28A, #29A, #29B, #30A, #30B, #31A, #31B, #34A, #41B, #43A, #43B, #46A, #49A,
#58A, #7113, #73A, #76B, #77A, #78A, #78B, #80A, #80B, #81A, #8113, #82A, #82B & #83A did not
meet the code allowed minus 10% deviation and needs to be re -stressed. Please re -stress the tendons
indicated above as outlined in the contract documents and provide our office with the re -stressing report.
It is our opinion that all other tendons have been adequately stressed and can be burnt off to a distance of
3/4" inside the exterior surface of the concrete. Stressing pockets should be packed with grout as
outlined in the contract documents.
If you have any questions or need additional information, please contact our office.
Sincerely,
Anchor Engineering, Inc.
Charles D. Petzmger, P.E.
Project Engineer
❖ 2535 17TH STREET, DENVER, CO 80211 303-783-4797 s% 303-830-9133 FAX ❖
City tat
�CoNvou.Niry
Wheat id9e DEvkti rml-tiT
FOR OFFICE USE ONLY
Approved by:
Inspector Date
City of Wheat Ridge Municipal Building 7500 W. 24'h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303 235.2857
FOUNDATION SETBACK AND ELEVATION CERTIFICATION
For Commercial and Multi -Family Developments
This form must be fully completed by a Professional Land Surveyor licensed in the State of
Colorado. This form must be accompanied by a Construction Control Plan following the
procedure found on the reverse side of this form.
DATE: MAY 13, 2020
PERMIT#
ADDRESS: 4050 CLEAR CREEK DRIVE, WHEATRIDGE, CO
LOT 1 , BLOCK 1 , OUTLOOK AT CLEAR CREEK CROSSING SUBDIVISION
SURVEYOR:
I hereby certify that the elevations and distances shown on the attached sheets and as stated
below for the recently formed or constructed structural foundation for the above property have
been measured by me or directly under my supervision.
See the attached Form Check and Sheets 15 & 16 of the Construction Control Plan
All measurements have been determined on the following location:
(Check only one): X Top of proposed foundation wall prior to placement of concrete
Top of foundation wall subsequent to placement of concrete
The setback and elevation measurements are included on the attached Const !:A Control Plan.
Signed �.t, atilt '-
Professional Surveyor
Print
Date
i ivwxi.lrheatridge.coms
Rev 11/2018
f
4
Or
a r�1m y
7C
U
C,
%0 %O
m A m X X
0 0; o x X
y
S
m
m
N 2
m
N
O�
nN
mm
m
-o
S X
Y am
�ArF
r
m
m
�m
m3�
Om
cm
h�O<
O
A
mN
Orx"
r
r
- -
�o prp
c7
mn
zac
z
aoa ac
�tT'� z
�
''—�
m
n0
�
f
4
Or
a r�1m y
7C
U
C,
%0 %O
Z
�I
SON'
omrn
-o
A
Y am
�ArF
m
m
m
m
�m
m3�
Om
cm
h�O<
O
A
mN
Orx"
r
r
�o prp
c7
Oo
8A
m
>
�tT'� z
e
2
¢pgc
�n
zJ
r•r
J
_m D
m m
Z
O m>
N
pZ
m -4 W
N
O
L
'�
m� m
mac
(%J
Y
D
C"1
m
r�+DD
O
2
y
x
O O
o
O
rn>m
O AM Oz
C
-,cm
8,
c
o
Z Z
Zm
O
O �m Z
c��
O
z
D fy
� g
OD
m
OmnN
,�
Or
Nmm
W
N
c
> Y
m
m
N m z co,
o
m z
I
rn
NNN
N
L7m
m
0 o
.Zpi
s
O ���
Z O O
NN
S
O
m
O
A
N
z
cmi
zi00
pp
Ln
M
f
ON �
7C
N j
{t
�Lf-
�I
SON'
omrn
o� j
+Cl
m3�
ON �
7C
N j
{t
�Lf-
029
MA-CHLIN-- - SEE SH --E- 14
N
—I.— I
Y:
rD
.........
F'
-
rD
— ----------------
9- � s)
(D
—I.— I
F'
-
ie
AF_
!13
t
MALHUNIE SEE SHEET 16
73'
—I.— I
T
c1l.
- Ell lily\ . \
........... ...................
Ar,
-A ---------- ---------------------------------------------------
gqS
-____________.__________-_Win - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - --
-1--
-Z—
VAI(;HLINL SEE SHEET 15
- — 1w — —
77,
z
T
c1l.
- Ell lily\ . \
........... ...................
Ar,
-A ---------- ---------------------------------------------------
gqS
-____________.__________-_Win - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - --
-1--
-Z—
OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: 16 3
Job Address:
Permit Number:
IJ No one available for inspection: Time A-- , AM/PM
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online at:
http;llwww.ci. wheatridge. co. uslinspection
D ate:_ Inspector:
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
�.�
Job Address:
Permit Number: C
❑ No one available for inspection: Time M/PM
Re -Inspection required: Yes 111'(0,,
When corrections have been made, sclie ule for re -inspection online at.
http://www.ci.wheatridge.co.0 nspe / f ---.
0
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: 1G/-C� i<'� tnz�-
Job Address: z� sem'
Permit Number: Z74./ C'-'?
❑ No one available for inspection: Time AM/PM
Re -Inspection required: (Yes: No
When corrections have been made, schedule for re -inspection online at:
http✓/www.ci.wheatridge.co.us inspection
Date: Inspector:
DO NOT REMOVE THIS NOTICE
t i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: 3R_s /Yl' 1
Job Address: `�-' 50
Permit Number: ?,-"-I-i cid 4A
❑ No one available for inspection: Time ` :,' pA-M%PM
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online at:
httpY www. ci. wheatridge. co. us4nspection
Date:" _ =' Inspector:
DO NOT REMOVE THIS NOTICE
i CITTOFWHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:/20 I -�--
�"
Job Address: �.
Permit Number: _ I R�z
z._
❑ No one available for inspection: Ti
_d M
Re -Inspection required: Ye No
When corrections have been made, jsehed le for re-inspec�v online at:
http✓/www.ci.wheatridge.co.u�nspection
C
FOR OFFICE USE ONLY
Approved by. Rjq
City of ��'euaaa�, 5)15)2020
CWheatge
�MMt1Nlw DEVELOPMENT Inspector Dale
City or Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857
FOUNDATION SETBACK AND ELEVATION CERTIFICATION
For Commercial and Multi -Family Developments
This form must be fully completed by a Professional Land Surveyor licensed in the State of
Colorado. This form must be accompanied by a Construction Control Plan following the
procedure found on the reverse side of this form.
DATE: MAY 13, 2020
PERMIT# 201902580
ADDRESS: 4050 CLEAR CREEK DRIVE, WHEATRIDGE, CO
LOT 1 'BLOCK 1 OUTLOOK AT CLEAR CREEK CROSSING SUBDIVISION
SURVEYOR:
I hereby certify that the elevations and distances shown on the attached sheets and as stated
below for the recently formed or constructed structural foundation for the above property have
been measured by me or directly under my supervision.
See the attached Form Check and Sheets 15 & 16 of the Construction Control Plan.
All measurements have been determined on the following location:
(Check only one): X Top of proposed foundation wall prior to placement of concrete
Top of foundation wall subsequent to placement of concrete
The setback and elevation measurements are included on the attached Eonstmstidn Control Plan.
Signed
Print Aaron Murphy
Date 5-13-20
wwx'.ri.x heatriJge.co.us
Rev 1112018
GENERAL NOTES:
1. THE LINEAR UNITS FOR THIS SURVEY ARE U.S. SURVEY FEET.
2. THE PURPOSE OF THIS FORM CHECK IS TO SHOW THE DELTAS BETWEEN
THE AS MEASURED FORMS AND THE PROPOSED BUILDING LOCATION.
3. THIS EXHIBIT DOES NOT CONSTITUTE A TITLE SEARCH BY HARRIS
KOCHER SMITH TO DETERMINE OWNERSHIP OR EASEMENTS OF RECORD.
4. THIS EXHIBIT DOES NOT REPRESENT A MONUMENTED LAND SURVEY.
SPECIFIC NOTES:
1. THE FIELD WORK WAS PERFORMED ON APRIL 30, 2020.
2. BENCHMARK: BASIS OF ELEVATION BASED ON NGS CONTROL POINT T
412", A STAINLESS STEEL ROAD AT THE INTERSECTION OF KIPUNG
STREET AND WEST 32ND AVENUE WITH A NAVD88 ELEVATION OF
5,562.74. T 412" IS A FIRST ORDER, SECOND CLASS CONTROL POINT.
3. FORM CHECK ELEVATIONS ARE MEASURED TO TOP OF FORM UNLESS
OTHERWISE NOTED.
LEGEND
XX.X' DENOTES THE DISTANCE BETWEEN THE AS—MEASURED
AND THE PROPOSED LOCATION
XXXX.XX ELEVATION
FORM CHECK AS—MEASURED LOCATION
C O.XX CUT TO PROPOSED ELEVATION (INDICATES FORM IS HIGH)
F O.XX FILL TO PROPOSED ELEVATION (INDICATES FORM IS LOW)
30 0 30 60
SCALE: 1" = 30'
OUTLOOK CLEAR CREEK CROSSING
I v CHECK
�
•� UVUUVU UUU
I
B
I
5456.97
FORM CHECK STEM WALL
F 0.02 II
FF CHK
\ F 0.01
5456.30
FORM CHECK
F 0.02
0.00
5456.30
FORM CHECK
F 0.02
IIS
'.5456.97
FORM CHECK STEM WALL
F 0.02 ,.
o '
c 0.02'
FCFF
2 :.'•I
KK
M. RVISIxww
KOCNER OUTLOOK CLEAR CREEK CROSSING
CSMITH HARRIS EVERGREEN DEVCO, INC. FORM CHECK
„mks;I IIIIWI 6=,=6311 BUILDING 4
FORM CHECK
F 0.02
5457.00 iH
FORM CHECK STEM WALL=
C 0.01
i
i
i
i
,
3
I �
i o
I. �..�.. ..—..--u—
�c
,I
s
MATCHLINE — SEE SHEET 10
.Ly- J V V
e
F=5166.]6
O AB R=
KEYMAP
., 5
g
•fu— ••Ir•ra••uu•Dei•.au aar•.•a.•ur•rrrr•a•••••a•••ra•o•uoe•b••••'a.faaa
w
4.
N I
•
ema • • � w
w
M—c ;t •.
w • ."'.ai •y.Ia •� • N
� I Cron = • ° _
i m n• : a tofu I Ml.._._
W lw.— ° u— •• Yy
S � lml Crru� `l l: wrry O •-� I I
Q EU Uw.n f!e. �ndnMgx 9 �
sM !'. mm ".lwE Cwa® .•vWn Uq • CEY:R1f NOBS
M Lwin fi Ucaurq_ wwapO� I%I � ryE AEM nMS ttF Ir 9MNr of 154n1111[O
¢T
• : s r E 14EH K m5l4Fu uk[x is IM YP R'ek tti'M[•
e b uP "TI, 71 nu :Y i ITLE 5 1111 Nl'AG
p••w • xMIE6 ]ERPUWiMYP9lo psPMYlinWP3 ntlIE
L r G[vMu — yIr.SU•a• 4u . ••V r�Nr•••t•to�^
AD FF--
'
meI,
i(AVERAGE ICP OI fCFM=.-5fi ).. "'DCII:.
\/j v1:/l�nlu)m • Trt 0ln Ma xrs lWi�[R:.M•fAAS'm
9••• 45a Mrvx1�.Nna lrq k
i J Ew muOMrxaa liMM �r•aQrd • • �
• / '4 r.mA w v .a
II IT.
a
Damn a••, O i
•
4amn (M_ • q °'RPA(
• • 11 RO IM=PYGNLF' uq RV
O ? J wM Y,
rj y" �� ❑ a
.—..— t,.... . ®III ?
o�AOo�,�
IM ca.n,oP' • +w- Pq.PON MU9 to
t .4�� w ..a � M fu_ • • O 4 K0. :0610) ^p p c S' i
�
YVMATCHLINE —SEE SHEET 19 2ti`�;✓;;"�3-ie •' `
z
k, A'�RRSJ ISSVE WiE 161vA19 PIMIECtM 1]016 $II.FbT1�
ECalyaileg. 10�– °�i0 m ER O OUTLOOK CLEAR CREEK w�.f« RewW,,sonmAMRur:
Evergreen 15
CONSTRUCTION CONTROL PLAN
o uWrtroxl axrsw.w w�.x-.r rsmum.i D.,r l,.rll WWI.. InI...nlx
n or 24
i MATCHLINE - SEE SHEET 11
U U U I I
I l
' Ie I
1e I
i FF=50.ffi]B
AB fF=_ I I
i I I
I
• I I
III l
a .
tta — I:smx I
.......................°(ml.. \..e....... a — 4..eCY � ..:...i.... +{yam
� e4 arca caa» .. 1�su.w wwun I I
c.wn I" o I I I
I ta_ Tu_ Ita u.w ay.
e dia vx
lll taI I
�.— I I I
I---------------
' H
III EYERCREEN CLEAR CREEK
' CRMEEK LLC
i CLEAR CREEL( CRMNG
ypa I AIBDINSIgI BIINC N0. 3
li a Ita trt m-
aL
000-
FF.5f5&l2 •••r• I I
AB FF=
(.VERAV TOP OT FORV = 54.6 3N
1 I
.w. rrov
ar» c. _ I
I l
u.+.n o� n I I
_II
w
— nce I. u.—.a. �eaka I I
_ I
L wa
L.._ _..
efl I I
7 ASH
MATCHLINE - SEE SHEET 20
� yWao- ��lCHER OUTLOOK CLEAR CREEK
." Q Evergreen CONSTRUCTION CONTROL PLAN
pi•µuceurpryyvygryryuFy,.E. _--__. _. Wrmxmn2mm•um Development Sernc.a l lave.<menf.
KEYMAP
sN�R1x01C5
"mo
.xr wPv. re-
owr°s':.aiwcnou'
.me. en It upov.xPx:+�+' no, .'i. aV.rv's�.rxrt'. r
• `.v1 •a, a[ -as[... +:ruuwm ue vxnN
�PFTm: xC4i
t[I w✓+ mu yam
. v .
I Meme uorLos.• '•. ol. t"e1w.
miwm wrta�nxoo, v. >•[
M&
m �QL�OiI�
%PpRON y� 111
to",.1.1
or,A-,. Win"gym
..rE.. BTM,
.Stip nm�e `114:ETNO.
IIBIiS
16
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: 461 t��gc__
Job Address:
Permit Number:
I
❑ No one available for inspection: Tim �M M
Re -Inspection required: Yep
When corrections have been
httpYA,vww. cL wheatridge. co, u
Dade
for re -inspection online at:
G
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: 7
Job Address:
Permit Number:
r
❑ No one available for inspection: Time f-AM/PM
Re -Inspection required: Yes !' Noj
When corrections have been made, schedule for re -inspection online at:
http✓/www. ci. wheatridge. co. uslinspection
Date: :c - y- f (-' Inspector: %. ✓1-)_
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
'x. ..
Inspection Type: `
Job Address:
Permit Number: CD
i
❑ No one available for inspection: Tim t -Z� M
Re -Inspection required: Ye�
When corrections have been made, schedUl _for re -inspection online at:
httpJ/www.ci.wheatridge.co.uslinspectia i
Date:¢ r pectora"
it
l I
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: f �'� u'✓
Job Address:
Permit Number: zw y Gz .5,iry
s
❑ No one available for inspection: Time 7 ' ' AM/rM
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online, of,.
httpYlwww.ci, wheatridge.co.uslinspection
Date: z` *;� Inspector:
DO NOT REMOVE THIS NOTICE
.�
��r%✓, Wiz-
� �A
.L1 r; � rt
s
❑ No one available for inspection: Time 7 ' ' AM/rM
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online, of,.
httpYlwww.ci, wheatridge.co.uslinspection
Date: z` *;� Inspector:
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: 3121 fic1� r
Job Address: 4�&50 CU --'Yr
Permit Number: 2L/l`7 c-, :Z 5'2(0
'0 .
❑ No one available for inspection: Time {'
Re -Inspection required: Yes t._N �
When corrections have been made, schedule for re -inspection online at:
http✓/www. ci. wheatridge. co. uslinspection
Date:
Inspector: N
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office rj
INSPECTION NOTICE
Inspection Type: ?CA1 /)ee_,1rv3'r
Job Address: hK,,SC% 4*?1tA< !�1?
Permit Number: cU1�f C/?� seewo
�.I�- - s -I,,--' A: � ,�tr� °-
❑ No one available for inspection: Time ^� AM/PM
Re -Inspection required: Ye . No 4,<;rz<
When corrections have been made, schedule for re -inspection online at:
http✓/www.ci. wheatridge.co. us4nspection
Date: -�Inspector: I \, '
DO NOT REMOVE THIS NOTICE
41 CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: /G_S 561L k/444
Job Address: *41050 CIU -4f
Permit Number: zrwlef 0�
/?z -
J No one available for inspection: Time /0, < J 6AZ/A/l
Re -Inspection required: Yes No
When corrections have been made, schedule for re -inspection online at:
http.-Ilwww.ci.wheatridge.co.uslinspection
Date:— � - 30, 2O Inspector:
DO NOT REMOVE THIS NOTICE
No C.O. may be issued until public improvements are complete
as identified in the Subdivision Improvement Agreement.
All landscaping shall be installed in accordance with the
approved landscape plan (Case No. WZ-19-01) prior to C.O.
and pursuant to the phasing identified in the Subdivision
Improvement Agreement. Per the SIA, installation of
landscaping, street trees, and irrigation is not required prior to
Certificate of Occupancy if issuance of the C.O. occurs outside
of the planting season, generally October to June.
Reviewed for Zoning Compliance by the
City of Wheat Ridge Planning Division
APPROVED -4
BY: u
DATE: i1
COMMENTS: Architectural elevations shall match the approved
master plan permit.
�1ADDRESS PLAN
r = 30.0'
1110 ®
KEPHART
Evergreen
0
Z
U)
U)
O
W
U
W
W
U
W
J
U
O
O
H
O
ADDRESS PLAN U
City of
W heat jjdge
COMMUNITY DEVELOPMENT
City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857
August 27, 2019
OFFICIAL ADDRESS CHANGE
NOTIFICATION is hereby given that the following address has been assigned to the property/properties as
indicated below:
NEW ADDRESS: See Page 2
FORMER ADDRESS: Vacant Land
• Subdivision: Clear Creek Crossing Subdivision Filing No. 2, Block 1, Lot 2, Section Parcel #: 39-194-04-
009
NOTES: This is a courtesy notification.
AUTHORIZED BY: l- � t� DATE: c1
r
DISTRIBUTION:
1. Property Owner
2. Addressinggieffco.us Jefferson County Assessor: Data Control, Lacey Baker; Jefferson County Elections:
Holly Roth; Jeffco IT Services (Mapping): Steve Mitchel
3. Jeffco Public Schools, ATTN: Communication Services, 1829 Denver West Dr., Bldg. 27, Golden, CO
80401
4. U.S. Post Office, 1100 Johnson Rd., Golden CO 80401
5. Email to erlinda i.martinez &usps.aov and arlene.a.vickrey(&,,usps.gov
and sheena.l.abeytaAusps.gov
6. Xcel Energy, sandra.cardenas(iDxcelenergy.com
7. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221
8. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112
9. Consolidated Mutual Water District