Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4076 Clear Creek Drive
(DNSC)LIE:)ATEE) mutual water SOIL AMENDMENT INSPECTION WWW.CMWC.NET Date: 4/8/2021 Time: I 9:30AM Employee: Robert Hazel Address: 4076 Clear Creek Dr. Status: 201992586 APPROVED Comment: Ok to final. For Inspection or to re -schedule an appointment, please call 303-238-0451. 48h our notice must be given for appointment USE WATER WISELY - CONSERVEI Colorado Department of Public Health and Environment Laboratory Services Division 8100 Lowry Blvd. Denver, CO 80230 Phone: 303-692-3090 Fax 303-344-9989 Analysis Report Work Order#: 1596262 (Environmental Microbiology, Wa) Chain of Custody #: Description: Client: PLATTE RIVER PLUMBING Report To: LLOYD DECKER Profile: Environmental Microbiology, Water PLATTE RIVER PLUMBING PO BOX 640 Henderson, CO 80640 Sampled By: MEGAN LLOYD.PLATTERIVER@HOTMAIL.COM Sample Summary Lab ID Sample ID Sample Type Test Method Date Collected Date Received Analytes Reported 2100761739 095-20 Water Total Coliform and E. coli 04/05/21 15:00 04/05/21 15:36 2 P/A 2100761740 095-21 Water Total Coliform and E. coli 04/05/21 14:52 04/05/21 15:36 2 P/A AWin�l •lA_ Scientific Director Note: The samples were tested as received from the customer and the results in this report relate only to the samples tested. Tuesday, April 06, 2021 3:00:20 PM Page 1 of 3 Report ID: 1596262 - 15109778 -ERED By MRL = Minimum Reporting Limit; BDL = Below Detection Limit, *= Comment applied HORIZON' MCL = Maximum Contaminant Limit per EPA regulations, 3004 o 0 mg/L - milligrams per liter (ppm); ug/L micrograms per liter (ppb); pCi - picoCuries Colorado Department of Public Health and Environment Laboratory Services Division 8100 Lowry Blvd. Denver, CO 80230 4076 Clear Creek Dr Phone: 303-692-3090 Fax: 303-344-9989 201902586 Analysis Report Work Order#: 1596262 (Environmental Microbiology, Wa) Sample Results Chain of Custody #: Lab ID: 2100761739 Sample ID: 095-20 Sample Type: Water Date Collected: 4/52021 15:00 Collection Site: Date Received: 4/52021 15:36 Site Description: Description: 10-201 LAV EVERGREEN CLEAR CREEK 4076 CLEAR CREEK DR WHEAT RIDGE CO 80401 EPA 92238 (Total Coliform and E. coli P/A) Parameter Results Units MRL MCL DF Prepared Analyzed Qual COLIFORM P/A ABSENT 1 4/62021 13:47 E. COLI P/A ABSENT 1 4/62021 13:47 Additional information Water Type: UNKNOWN Analysis Result Comments Analyte: COLIFORM P/A • ACOLIFORM P/A result of "ABSENT' indicates a microbiologically safe sample , Coliform was absent or less than one (<1) Coliform per 100mL Analyte: E. COLI P/A • An E.COLI P/A result of "ABSENT' indicates that E.coli was NOT DETECTED. Tuesday, April 06, 2021 3:00:20 PM Page 2 of 3 Report ID: 1596262 - 15109778 POAE RED BY MRL=Minimum Reporting Limit ;BDL =Below Detection Limit, *= Comment applied HORIZO03004 7 0 MCL = Maximum Contaminant Limit per EPA regulations, mg/L -milligrams per liter (ppm); ug/L micrograms per liter (ppb); pCi - picoCuries CERTIFICATE OF OCCUPANCY Permit #: 201902586 � �� Wh6atpsig COMMUNITY DEVELOPMENT 7500 W 29TH AVE WHEAT RIDGE CO 80033-8001 Date: 03/10/2021 *Stipulations: Clear Creek Crossing - Two story residential building, 3 units, tuck -under garage - 3,753 sq ft total This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code, Zoning and other related land use and development laws of the City of Wheat Ridge, and may be occupied for the use specified. OWNER: EVERGREEN CLEAR CREEK CROSSINCADDRESS: 1873 S Bellaire St 1106, Denver, CO 80222 CONTRACTOR/ADDRESS: NEXUS BUILDERS 1873 S Bellaire St Suite 1200, Denver, CO 80222 PROPERTY ADDRESS: 4076 Clear Creek Dr, Wheat Ridge, CO 80033 PARCEL #: 39-194-04-003 ZONING: PCD OCCUPANCY: R-2 TYPE OF CONST: V -B OCC LOAD: 36 FOR THE FOLLOWING PURPOSE: Single Family -New Code Editions: 2012 ICC / 2017 NEC No change shall be made in the Use of this building without prior notice and a new CERTIFICATE OF OCCUPANCY from the City of Wheat Ridge Certificate MUST be posted by front door of commercial occupancies Chief Building Official Sprinklered: Yes Zoning Administrator _ i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: .o/ -S Job Address: e— Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: Inspector: DO NOT REMOVE THIS NOTICE December 11, 2020 Evergreen Development 1873 South Bellaire Street, Suite 1200 Denver, CO 80222 Attn: Evergreen Development Re: Compliance Letter for Special Inspections Outlook Clear Creek, Permit No.: 201902586 4076 Clear Creek Drive, Building 10 Wheat Ridge, CO CG Project Noe. 19.23.225 Cole Garner f-AmAo technical 1070 W. 124 t" Ave, Ste. 300 Westminster, CO 802 34 303.996.2999 At your request,, Cole Garner Geotechnical (CGG) was retained to provide construction special inspection and materials testing for the above-named project. Observation and special inspection services were performed as scheduled by the contractor during the construction of the following elements: Fairestoppoing - periodic visual special inspection of membrane penetrations to verify adherence with manufacturer recommendations for UL rating Wood Framing -visual inspection of shear and gravity systems including member size, grade and orientation including hardware and fasteners The results of our special inspections were noted to comply with the approved project plans, specifications and relevant sections of the International Building Code. We trust that the information presented herein satisfies your present needs. Sincerely, u irner Geotechnica Thomas C. Cole, P.E. Principal Cole Garner f-AmLv technical 1070 W. 124 t" Ave, Ste. 300 Westminster, C 111111111111) 802 34 July 14, 2020 Evergreen Development 1873 South Bellaire Street, Suite 1200 Denver, CO 80222 Attn: Evergreen Development Re: Compliance Letter for Special Inspection and Materials Tests Outlook Clear Creek, Permit No.: 201902586 4076 Clear Creek Drive, Building 10 Wheat Ridge, CO CG Project Noe. 19.23.225 303.996.2999 At your request,, Cole Garner Geotechnical (CGG) was retained to provide construction observations and materials testing for the above-named project. Observation and special inspection services were performed as scheduled by the contractor during the construction of the following elements: Excavation Observation -observation prior to foundation construction to verify conformance to with geotechnical report Reinforced Concrete -inspection of reinforcing steel and concrete placement for foundations and slabs Concrete Encased Grounding Rod - inspection of placement of Ufer ground rod in foundation Post -Tensioned Concrete - inspection of tendon layout,, concrete placement operations and subsequent stressing operations In addition, materials tests were periodically conducted for the following elements: Concrete - temperature, slump, air content,, unit weight and compressive strength; The results of our materials tests and special inspections were noted to comply with the approved project plans, specifications and relevant sections of the International Building Code. We trust that the information presented herein satisfies your present needs. S incerely, arner Geotechnical Thomas C. Cole, P.E. Principal !'Do Ll 'r GOO 06 s .NA ao 425 18 0000 s 0 71A 20 /ON AL EN�\� 71 c c Z 2 4076 Clear Creek Dr 2019 02 586 rot c: Q O. v CD O v � c CD Q �. (D O to m m r+ 3 ted. CD Q oJ. CL 7 CD �% fn e+ CD fZ 0 - CD N N m -o O Oz/^ cf) C mm D N m z -i n Q Q N N � N N n t!� 0 0 ❑ ❑ ❑ ❑ ❑ ❑ C LX. ❑ O D 0 Q ❑ Q C 0 ❑ ❑ I� ❑ ❑ ❑ o -ri y Q w CD — n cn UI I (r I I CD I 2, m I c� -0 z cn -� o `Q �� o O I� W m�, CD c Icn c73 cc a �CD m c -��•B ° F5S `* I I p m CD C9 m T n � sp z o y !� =4 cn =r'G O CD C cn G = a = CD o � o 4076 Clear Creek Dr 2019 02 586 rot c: Q O. v CD O v � c CD Q �. (D O to m m r+ 3 ted. CD Q oJ. CL 7 CD �% fn e+ CD fZ 0 - CD N N m -o O Oz/^ cf) C mm D N m z -i n Q Q N N ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office j INSPECTION NOTICE Inspection Type: r % Job Address: "0—* © Permit Number:, j p 20 I t ❑ No one available for inspection: Time ? `? AM�'�-' V Re -Inspection required: °"Yes�No When corrections are complete, schedule re -inspection online. Date: — ® Z. / inspector: -9 DO NOT REMOVE THIS NOTICE The City of Wheat Ridge 7500 W. 29th Avenue, Wheat Ridge, CO 80033 Third Party Form Check List Property Address �. 7 C«e cwk m i/ - Permit Number Permit Issued Date 201902586 Owner Information Property Owner Information Property Owner Address Inspector Information Inspection Company e ohJN �(o Inspector Name OVAP Inspector Contact Contact info. Otip, 5,1,"N,C7-7—G Bui4.,0/tj6- flN�.cov� Inspector Statement and Acknowledgement * I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's recommendationd pecifications. rV Inspector: �!, Date: 3 9/21 Property Owner Statement of Acknowledgement *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Ridge Building Division inspection. Propery Owner/Agent: Date: This original document must be submitted to the Chief Building Official within seven days of the final inspection. Email to permits@ci.wheatridge.co.us Please add note to reverse side The City of Wheat Ridge 7500 W. 29th Avenue, Wheat Ridge, CO 80033 Third Party Form Check List Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Mid -Roof PROPERTY ADDRESS y07 C LLA -9r -K, �Q,L/g,— Roof Inspection ❑ N/A ❑ Pass ❑ Fail 0 N/A ❑ Pass ❑ Fail Structural roof components X N/A ❑ Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A Pass ❑ Fail Flashing for roof and walls Q Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A [ Pass ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/A ® Pass ❑ Fail Crickets and saddles where needed FKJ N/A ❑ Pass ❑ Fail Verify B vent must have boot same gauge as pipe ® N/A ❑ Pass ❑ Fail Verify vent caps [A N/A ❑ Pass ❑ Fail Verify no flashings are damaged or rusted N/A ❑ Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A 0 Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A © Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A ® Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A N Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A [ Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A © Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC [ N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 FK] N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ® N/A ❑ Pass ❑ Fail Above roof insulation R-25 ❑ N/A LK Pass ❑ Fail Below roof residential R-38 R] N/A ❑ Pass ❑ Fail Below roof commercial R-32 [A N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements g] N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 © N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ® N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements [[ N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes �ii'ieu-C-Y4�A L V�� F, ��_�� l� N�'!'rJ�►6 ( ;� ,�. pR N� �i�a S Nl alb to ar L/fQl F,rsD _4r—T �}L, Company Name: .n r 4 0 pC Inspector signature: Date of Inspection: o The City of Wheat Ridge Inspection Check List notes Final Roof PROPERTY ADDRESS: `i07(o Roof Inspection ❑ N/A ❑ Pass ❑ Fail [ N/A ❑ Pass ❑ Fail Structural roof components N/A ❑ Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A � Pass ❑ Fail Flashing for roof and walls EK Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) K N/A ❑ Pass ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/A ® Pass ❑ Fail Crickets and saddles where needed ❑ N/A © Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A Pass ❑ Fail Verify vent caps ❑ N/A ® Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A Q Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A [ Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A �1 Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A ® Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A] Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 Q N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ® N/A ❑ Pass ❑ Fail Above roof insulation R-25 ❑ N/A I)X Pass ❑ Fail Below roof residential R-38 `� N/A ❑ Pass ❑ Fail Below roof commercial R-32 K N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications - Must have manufacturer's letter of warranty with the address on the tetter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 Q N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ® N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name: u Ij- N4u L- -I P -/b, Inspector signature: Date of Inspection: fl o 2 0 i' i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office I INSPECTION NOTICE Inspection Type:�f —` i rt JobAddress: Permit Number:5 ❑ No one available for inspection: Tirm Re -Inspection required: Yes Flo When corrections are complete, schedulei�r De Inspector: AM/PM online. i CITY OF WHEAT RIDGE - Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE `�- Inspection Type: Job Address: ---_� - Permit Number: 1 I r � 7, 1:_4C4>Z ❑ No one available for inspection: Tim- _ M/PM Re -Inspection required: Ye§ No -- *When corrections are complete,`Scherlu` e -inspection online. 0 4' CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: )p F/ Al T1 Job Address: Permit Number: _-2-C21 C7 5z r, I 1 —7 - IJ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections are complete, scheddte re -inspection online. Date: Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Single Family - New PERMIT - 201902586 PERMIT NO: 201902586 ISSUED: 02/19/2020 JOB ADDRESS: 4076 Clear Creek Dr EXPIRES: 08/20/2021 JOB DESCRIPTION: Clear Creek Crossing - Two story residential building, 3 units, tuck -under garage - 3,753 sq ft total *** CONTACTS *** OWNER EVERGREEN CLEAR CREEK CROSSING GC (303) 757-0401 Ron Wolford 180393 Nexus Builders LLC SUB (303)795-6116 MONTE LOSAW 160078 LOSAW ELECTRIC INC. SUB (303)288-2308 WILLIUAM C COFFEY III 110081 PLATTE RIVER PLUMBING INC. SUB (720)373-4378 CORY JOHNSTON 190344 CBA MECHANICAL *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 436,800.00 FEES Total Valuation 0.00 Plan Review Fee 120.00 Use Tax 91172.80 Permit Fee 31305.70 Engin. Review Fee 100.00 ** TOTAL ** 12,698.50 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. All landscaping shall be installed in accordance with the approved landscape plan (Case No. WZ-19-01) prior to C.O. and pursuant to the phasing identified in the Subdivision Improvement Agreement. Per the SIA, installation of landscaping, street trees, and irrigation is not required prior to Certificate of Occupancy if issuance of the C.O. occurs outside of the planting season, generally October to June. Architectural elevations shall match the approved master plan permit. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Single Family - New PERMIT - 201902586 201902586 ISSUED: 02/19/2020 4076 Clear Creek Dr EXPIRES: 08/20/2021 Clear Creek Crossing - Two story residential building, 3 units, tuck -under garage - 3,753 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 02/19/2020 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ♦� City of Wheatldge COMMUNITY DEVELOPMENT CityofWheat Ridge Municipal Building 7500 W. 20 Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Permit Extension Request Form Permits expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days may be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. Please complete this form in its entirety and submit to the Building Division at permits(cilci.wheahidge.co.us or fax to 303-237-8929. Party requesting permit extension: Evergreen Clear Creek Crossing Permit # 201902586 Property Address: 4076 Clear Creek Dr. Phone# 720-272-8725 Email Address: adeckert@evgre.com Reason for extension request: Delayed construction start Number of days requested: 3/31/2021 Printed Name: Amy Deckert Signature:_z"—' Date: 02/22/2021 For office use only This request has been: $I Approved ❑ Denied Extended =it 8/20/2021 Approved by: -#�'% %—Izi o¢ Date: 2/22/2021 www.ci.whealridgaco.us A 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: -'i o6 Permit Number: (j,-) Z_ 57 1_J No one available for inspection: Time AM/PM Re -inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: Inspector: 51� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection .-iQ;Xu Permit Number: e2Lnq ❑ No one available for inspection: Tin AM/PM Re -Inspection required: Yes No When corrections are complete, sched� re -inspection online. Date, Ins nn n►nT M CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: D w__S Job Address: 10 -7 C14r C,^ Permit Number: c) S' U No one available for inspection: Time -7f.r AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: /- q - Z-11 Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: �-�' I C -) ❑ No one available for inspection: Ti Re -Inspection required: Yes' When corrections have been made, sc,keduli http✓/www. ci. wheatridge. co. usllnspe¢tio D�hnspe AM/PM . for re -inspection online at. ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: - Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http://www. ci. wheatridge.co. uslinspection Date:—/? `W-�,( Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: /-A tryr.f Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http://www. ci. wheatridge. co. usfinspection Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: - ❑ No one available for inspection: Time iAWPM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http://www. ci. wheatridge.co. usfinspection Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF wHF-At RIDGE , Building'lnspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type Job Address: Permit Number:`� ❑ No one available for inspection: Tine M/PM Re -Inspection required: YesIt N> When corrections have been made, edule for re -inspection online at: http✓/www.ci.wheatridge.ao.uslinspe t~--� -- 1 Yq4i` to Insrpect0. � A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:_ Job Address: �= Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes When corrections have been mad s edule for re -inspection online at: httpYAvww.ci.wheatridge.co.usrns ctio DaWZ ns�eector i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: arA=r P Permit Number: ❑ No one available for inspection: Ti ZIN Re -Inspection required: Yes & M When corrections have been ma e, sc ule for re -inspection online at: http ✓/www. ci. wheatridge. co. u�qspectigr i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: (4(2:;66 C Permit Number: -2 124 ❑ No one available for inspection: Tim '-f M/PM Re -Inspection required: When corrections have been http✓/www. ci. wheatridge. co, u r , - VE T Yes for re -inspection online at: i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: (s"' ��w �._ Job Address: Permit Number: �.. ❑ No one available for inspection: Time % AM/PM Re -Inspection required: Yeses cam' When corrections have been made, schedu* forceminspection online at: http✓/www.ci.wheatridge.co.us4nspedtion Dateg . s i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: ,k; :z Job Address: Permit Number: 'f ,. f L,. Z 11--1911 - ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at., http✓/www.ci. wheatridge. co. usfinspection Date: Inspector: DO NOT REMOVE THIS NOTICE Clear Creek Crossing Building 10 4076 Clear Creek Drive Permit No. 2019 02586 ANCHOR ENGINEERING STRUCTURAL ENGINEERS May 11, 2020 Kephart Architects Attn: Janet Grady 2555 Walnut Street Denver, CO 80205 RE: Outlook Clear Creek Building 10 4076 Clear Creek Drive Wheat Ridge, CO 80215 Dear Mrs. Grady, Per our contract, our office reviewed tendon elongation report dated April 30, 2020 provided by Cole Garner Geotechnical for the above referenced project. The reports indicate that the special inspector from Cole Garner observed as the tendons were stressed using the following equipment: Ram No. PT Jacks & Accessories 2018-020 (#210) Gauge No. McDaniel (#210), 10,000 PSI, 4" Pump No. SPX Power Team, S/N 376088 (#210) The equipment was last calibrated on April 15, 2020. The corresponding stressing gauge pressure is 5,440 pounds per square inch when applying 33 kips of tension to the tendon. A copy of the associated calibration curve was provided to our office for our records and review. Our office reviewed the original report on May 1, 2020 and numerous elongations were below the negative 10% deviation. After coordination with the special inspector from Cole Garner Geotechnical and Site Superintendent with Evergreen Development our office provided recommendations for re -stressing of the slab in an email dated May 6, 2020. Anchor Engineering was provided a revised report on May 11, 2020 indicating the elongations after re -stressing the tendons that were below the negative 10% deviation. Based on our review of the stressing records, calibration curve, PTI allowances of +/- 1/4" elongations for short tendons, and the knowledge of measurements taken to the nearest 1/8", it is our opinion that the tendons have been adequately stressed and can be burnt off to a distance of 3/4" inside the exterior surface of the concrete. Stressing pockets should be packed with grout as outlined in the contract documents. If you have any questions or need additional information, please contact our office. Sincerely, C Project Engineer 2535 17" STREET, DENVER, CO 80211 303-783-4797 303-830-9133 FAX •: a FOR OFFICE USE ONLY Approved by City of Wheat ig -�''" C OMMUNI TY DNE,1-0PMtNT Inspector Date City of Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2816 F: 303.235.2837 FOUNDATION SETBACK AND ELEVATION CERTIFICATION For Commercial and Multi -Family Developments This form must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This form must be accompanied by a Construction Control Plan following the procedure found on the reverse side of this form. DATE: APRIL 01, 2020 PERMIT# ADDRESS: 4076 CLEAR CREEK DRIVE, WHEATRIDGE, CO LOT , BLOCK T OUTLOOK AT CLEAR CREEK CROSSING SUBDIVISION SURVEYOR: I hereby certify that the elevations and distances shown on the attached sheets and as stated below for the recently formed or constructed structural foundation for the above property have been measured by me or directly under my supervision. See the attached Form Check and Sheets 12 and 13 of the Construction Control Plan. All measurements have been determined on the following location: (Check only one): X Top of proposed foundation wall prior to placement of concrete Top of foundation wall subsequent to placement of concrete The setback and elevation measurements are included on the attached Construction Control Plan, Sioned Professional Surveyor Print Date Hw'vr.ei.N heutrid�c.cir.u� Rev 11/2018 -Z 1 c� W na _ C (fj A 3 41 N .- rii ID a r X X NCD [} O O ASC X X X >C 9l• ` D �J T N Z rn N Cjj (irn*J� f J m n S T Z L X ] s LC-) r' C I R MP3• .o A C*)A "'�D m X m A x v; C Z m r mm ZNi a C m NW '=v D m X vat T LO cn �- ^o A Om ztv ;0v V, (^ v crn z prem m zm Q om ivNvrni'n -4 ri � O `�i V, N r I 'S D v z C 7 < d t/f W I A s z14 I_ N 2 taJ7 O O JN A in b v �A tn 007JzfA-a �On =0 to 8c) OOr m cn mvZ z� vg oo� �iCm R-'..2 c z O� m rn b 8 z n vm c^ n rrl+ m Z a R, A�x�an =� aN n a a`$ i� am_ c;l p z Z� O� 00 in OO zz [�'_i-� Zg O 0 Oazz x O AN m= C in v�Tz j T v o zi z c C tDn V1 nm Wg N O4'G � r U r _ V7� C C as m CT v= rA' -< Ln viLnn C �. rm V �p 'm'' C- Vl Vl 7x0 v Cz 2 O N -iW O o a Cmrl c� 010, _ C rn mT Ul Orn 3 41 p � C N of NCD " �l O _ C Orn omao �cn C " 9l• ` D �J D oC g rn n m w O J A rn �D R MP3• .o � m m =N m V, (^ CD ^Z^ Uf ai X 7- tTj IP 00 rn Al JNE SEE SHEET 1, log Q0 0 Fn m m I MAT(,'--LRiE SCE '31 E -T 12 VTCHM*AE - SF= SHEET 14 0 at rD Q0 0 Fn m m I MAT(,'--LRiE SCE '31 E -T 12 VTCHM*AE - SF= SHEET 14 0 at i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type`T Job Address: Permit Number: i ❑ No one available for inspection: Ti Re -Inspection required: Yes No When corrections have been made, scod l http:Uwww.ci.wheatridge.co.us4nspect on DaQ-0, 2 �6 Insp® or. AM/PM for re -inspection online at. CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: 41(-7c Permit Number: 7--- / -/ 16—e L) No one available for inspection: Time q. rAM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: hffpYlwww.ci. wheatridge. co. usVinspection 7- ?C-, - 7cl., Date: .`/ Inspector: _/�� REMOVE THIS NOTICE i i CITY OF WHEAT RIDGE Building Inspection Division (/ (303) 235-2855 Office INSPECTION NOTICE Inspection Type:O=----- Job Address: -r b Permit Number: -"2 ('a �5 ` . ` <::75� ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes When corrections have been made, schedule for re -inspection online at: httpJ/www.ci.wheatridge.co.uslinsp ction ""' -�••. Dat t Inspect r DO NOT ROVE THIS NOTICE I* � A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: /G 3 A!I. C -ter Job Address: '(,-1&-7d CzZf,,-f- e-.2Lt1< 1�lK Permit Number: -?,- ❑ No one available for inspection: Time Re -Inspection required: ,es" No When corrections have been made, schedule for re -inspection online at. http✓/www.ci.wheatridge.co.us inspection Date: �L ' Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Ti AM/ M Re -Inspection required: Yes No~ When corrections have been made, schedule for re -inspection online at. http✓/www.ci.wheatridge.co.uns ct, Date; �sp, c or, DO NOT REVE THIS NOTICE` FOR OFFICE USE ONLY APpmyed by _ City of 5/15/2020 W heat I qge pec or Dare COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 20 Ave. Wheat Ridge. CO 80033-8001 P: 303.235.2846 F: 303.235.2857 FOUNDATION SETBACK AND ELEVATION CERTIFICATION For Commercial and Multi -Family Developments This form must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This form must be accompanied by a Construction Control Plan following the procedure found on the reverse side of this form. DATE: APRIL 01, 2020 PERMIT# 201902586 ADDRESS: 4076 CLEAR CREEK DRIVE, WHEATRIDGE, CO LOT 1 . BLOCK 1 OUTLOOK AT CLEAR CREEK CROSSING SUBDIVISION SURVEYOR I hereby certify that the elevations and distances shown on the attached sheets and as stated below for the recently formed or constructed structural foundation for the above property have been measured by me or directly under my supervision. See the attached Form Check and Sheets 12 and 13 of the Construction Control Plan, All measurements have been determined on the following location: (Check only one): X Top of proposed foundation wall prior to placement of concrete Top of foundation wall subsequent to placement of concrete The setback and elevation measurements are included on the attached Construction Control Plan. Print Aaron Murphy Date 4-22-20 xwx.ei.xM1ealriJge.ex. us GENERAL NOTES: 1. THE LINEAR UNITS FOR THIS SURVEY ARE U.S. SURVEY FEET. 2. THE PURPOSE OF THIS FORM CHECK IS TO SHOW THE DELTAS BETWEEN THE AS MEASURED FORMS AND THE PROPOSED BUILDING LOCATION. 3. THIS EXHIBIT DOES NOT CONSTITUTE A TITLE SEARCH BY HARRIS KOCHER SMITH TO DETERMINE OWNERSHIP OR EASEMENTS OF RECORD. 4. THIS EXHIBIT DOES NOT REPRESENT A MONUMENTED LAND SURVEY. SPECIFIC NOTES: 1. THE FIELD WORK WAS COMPLETED ON APRIL 21, 2020, 2. BENCHMARK: BASIS OF ELEVATION BASED ON NGS CONTROL POINT "F 412", A STAINLESS STEEL ROAD AT THE INTERSECTION OF KIPLING STREET AND WEST 32ND AVENUE WITH A NAVD88 ELEVATION OF 5,562.74. 'F 412" IS A FIRST ORDER, SECOND CLASS CONTROL POINT. 3. FORM CHECK ELEVATIONS ARE MEASURED TO TOP OF FORM UNLESS OTHERWISE NOTED. LEGEND XX.X'— DENOTES THE DISTANCE BETWEEN THE AS -MEASURED AND THE PROPOSED LOCATION XXXX.XX ELEVATION FORM CHECK AS -MEASURED LOCATION C O.XX CUT TO PROPOSED ELEVATION (INDICATES FORM IS HIGH) F O.XX FILL TO PROPOSED ELEVATION (INDICATES FORM IS LOW) 10 0 10 20 SCALE 1'= 10' OUTLOOK CLEAR CREEK CROSSING FORM CHECK 5458.67 FORM CHECK - 5458.62 0 �0>• .�^ FORCHECK o� F 0.05 RM M O� , p ,moo 5458.66 .06, o FORM CHECK F 0.01 ^ti oos, p. 5458.64 FORM CHECK— / F 0.03 EVERGREEN DEVCO, INC.I OUTLOOK CLEAR CREEK CROSSING FORM CHECK BUILDING 10 5458.65 FORM CHECK F 0.02 4 o Ods p. ,mob S• p 5458.62 FORM CHECK F 0.05 1 MATCHUNE — SEE SHEET 7 EVERGREEN CEM MEEK CRMNG LLC CIEM CREEK CROSSING 9 BOIV19ON nUNG NO. 3 i z U 6 � MM, .0111 uas � nic gm.tr rvs ui cev[n[r+ rcrs �sJrtor nt WLWp4: nGMi9m mSRR:mxF pwfl9�e w..:.. �.... . xn FYO�IXks wpws:E.uyxutuu u_. SIO�S[r x`rt5'. IE ruo rm...s rawsrz.. m wm n.:wo. i p nlr.nw e.xa a xm.:. , xr: �n.`�,en mr ur�ca wx'llu acr.'w .m..I e .u,Mas CP, .wo- uuw.... xmsrz I wpnsrwa1n.11 nnn - w.wxpP .xo •o , mxrwa�x.,t� r +`wEn `a Wmi �'� xmw.nsehNpx. HARRIS I�wrE - .. emsroxcanuo+rs 'Sf�C' ��? AWR SER O Evergreen OUTLOOK CLEAR CREEK CONSTRUCTION CONTROL PLAN Gevalopmpnt SeEnco i Invutmenk MATCHLINE — SEE SHEET 8 m xnoYwrm.hNvx. o w R Cal MMelyvuY MA r'Yg—o—� MATCHLINE — SEE SHEET 17 A�R215 I O KOCHER Evergreen SM TH OOYplppmanl SMVIGaG Invaitmemi OUTLOOK CLEAR CREEK CONSTRUCTION CONTROL PLAN KEYMAP vu=.pw rEu.asi. inns rv� a i. mu mw. s IL Li Y1YFXnu �'.�vwS Wv u! vMNVS 0 bWPN4 iilui": -r aT EYV V11 IM51R.rt X mV YIFyH 11 ll X .RWy?. ip [[RPwM tlWiAWa rP PYYEx3 N s_. , +LMIruA xpi xFai[YAr. urvxruuFrriuu vx'X. WWn( WTI i w nw Gw+ YLi xwwLn: aYmi l,. w. LuvnX ox mssua xm ul�:. �T. xFrwxu.Yn xw. mu WXn mica rmawrnw v�n,� °�m n s�rnre ah. iw wa.xrt� ,.rmr Y r F mmw, r ;F9 i.. 'r OY 5 F Rr1 �7RA, 4tpl'. pXR Rwvn ' ' ),M YOIx�rtrV WpXV IM AXM'I XPI41u £JRVEIV.$ CPT. W 4upMY. 1?f➢irtXm ,lnxlwu'w u rXMM w euK n m M W�,J1a, Y, A.gA,^lr Wr'eu. AMm WrFn' �1m[f LTR rl'Ir� &R2...z 1"IET W,ulexrs 13� Inspection Type: Job Address: Permit Number: CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE `✓'r 7l i�`i-�f's _/� LT// GGA`' " �`P�'+C-G,�r�/}-!�lLi� / t" L/L>-'�.,✓��y�y, � ,%�' ❑ No one available for inspection: Time1C�r�C- A PM Re -Inspection required: es) No zf/-- � .LL`!!, When corrections have been made, schedule for re -inspection online at: h ftp✓/www, ci. wheatridge. co. us/inspection Date: Inspector: 00 NOT REMOVE THIS NOTICE € r A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: 'YGa76' Permit Number: ?u/q ;> ❑ No one available for inspection: Time .�°%f` Awl' ID , Re -Inspection required: Yes. No, When corrections have been made, schedule for re -inspection online at: http✓/www.ci. wheatridge.co.uslinspection Date:_':,"- �,:'t�-' Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: /"::5 5 Job Address: 416 iG CzZ4vf Permit Number: CIF .54s C `!G J'C' /`stir 's;."� ✓� .,.+cs�� f � a �,f~ �_'Y i;%',+"-, +• ; ❑ No one available for inspection: Time PM Re -Inspection required: Y� No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. uslinspection Date: = Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE �° r Building Inspection Division.�� (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Ti1Gl/P Re -Inspection required: When corrections have been made, schedule for re -inspection online at: http✓/www.ci.wheatridge.co.uslinspe ion U --A is rr- No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. All landscaping shall be installed in accordance with the approved landscape plan (Case No. WZ-19-01) prior to C.O. and pursuant to the phasing identified in the Subdivision Improvement Agreement. Per the SIA, installation of landscaping, street trees, and irrigation is not required prior to Certificate of Occupancy if issuance of the C.O. occurs outside of the planting season, generally October to June. Reviewed for Zoning Compliance by the City of Wheat Ridge Planning Division APPROVED „1 ADDRESS PLAN 1 30'-0' Architectural elevations shall match the approved master plan permit. KEPHARTI Q Evergreen 0 _Z Cn U) O U Y W W U W J U Y O O J O ADDRESS PLAN I`" City of W heat jjdge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 August 27, 2019 OFFICIAL ADDRESS CHANGE NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: NEW ADDRESS: See Page 2 FORMER ADDRESS: Vacant Land • Subdivision: Clear Creek Crossing Subdivision Filing No. 2, Block 1, Lot 2, Section Parcel #: 39-194-04- 009 NOTES: This is a courtesy notification. AUTHORIZED BY: l- � t� DATE: c1 r DISTRIBUTION: 1. Property Owner 2. Addressinggieffco.us Jefferson County Assessor: Data Control, Lacey Baker; Jefferson County Elections: Holly Roth; Jeffco IT Services (Mapping): Steve Mitchel 3. Jeffco Public Schools, ATTN: Communication Services, 1829 Denver West Dr., Bldg. 27, Golden, CO 80401 4. U.S. Post Office, 1100 Johnson Rd., Golden CO 80401 5. Email to erlinda i.martinez &usps.aov and arlene.a.vickrey(&,,usps.gov and sheena.l.abeytaAusps.gov 6. Xcel Energy, sandra.cardenas(iDxcelenergy.com 7. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221 8. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 9. Consolidated Mutual Water District 10. Applewood Sanitation District 11. West Metro Fire District 12. Wheat Ridge Planning Division 13. Wheat Ridge Building Division 14. GIS Specialist 15. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: www.ci.wheatridge.coms DATE: CLEAR CREEK Vicinity Map U95 A N