Loading...
HomeMy WebLinkAbout7867 W 43rd PlaceFrom: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Solar PV Installation Date: Tuesday, August 17, 2021 1:43:29 PM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 7867 W 43rd Place Property Owner Name Thrive Home Builders Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 720-584-4789 doedewaldt@thrivehomebuilders.com Electronic Payment Form Sunnova 8.17.2021.Ddf CONTRACTOR INFORMATION Contractor Business Namaste Solar Electric Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the 090413 Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Kyle Pegon Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. City of Wheat Ridge) Contractor Phone 303-447-0300 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email kyle.pegon@namastesolar.com Address Retype Contractor kyle.pegon@namastesolar.com Email Address DESCRIPTION OF WORK Scope of Work Master plan approved, over the counter permit. Installation of a new 3.0 kw solar array on each individual unit of the Westridge Yarrow Gardens community by Thrive Home Builders. Each array will be totally independent of each other, but will have a shared meter bank. Each solar array will be grid -tied, have no battery connection, and will utilize enphase microinverters. We will be installing Hanwha 340 watt solar panels and utilizing unirac's racking system with the ecofasten roof attachment system. KW 3.0 # of Panels 8 Location of Panels 8 on roof Structural required No Upload engineer letter Westridae MPS AHJ_stam end Ddf or pages on 8 1/2" x 11" only Solar Installation Plan 11X17 RFC PLOTPLAN WESTRIDGE LOT 15 7867 W 43RD Set on 11"x17" only. PL PLAN P12 -EA -S OR 1 JK375.Ddf Project Value (contract 6750 value or cost of ALL materials and labor) ,A lei uG\ Lei :».]0111101.7A:Ra IF-a01.lnEel Ga01owmel:»:1r�d:10r1 I assume full Yes responsibility for compliance with applicable City of Permit#: 202100888 cry of ',Wheat�ge COMMUNITY DMIAPMLNT 7500 W. 29th Ave Wheat Ridge CO 30033-6713 CERTIFICATE OF OCCUPANCY ]86] W 03rd PI, Wheat Ridge, DO 800334526 Date: 0222122 This certificate verifies that Me building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheal Ridge Building Code, Zoning and other related land use and development laws of the City of Wheat Ridge, and may be occupied for the use specified. OWNER: THB WESTRIDGE LLC 1875 Lawrence St 900, Denver, CO W202 CONTRACTOR: THB WESTRIDGE LLC 1875 Lawrence St 000, Denver, 0080202 PARCEL: 39-233-02052 7867 W 03rd PI, Wheat Ridge, 00 80033-0526 ZONING: MU -N TYPE OF CONST: V -B OCCUPANCY: R-3 OCC LOAD: 0 CODE EDITION: M181CC/2020 NEC SPRINKLERS: No FOR THE PURPOSE: SFD:Singl Family- New Limitations/Stipulations:none No change shall be made in the Use of this building without prior notice and a new CERTIFICATE OF OCCUPANCY from the City of Wheat Ridge Certificate MUST be posted by front door of commercial occupancies COnsc �, Chief Building Oficial Planning2oning Administrator Cornelia Orzescu Lauren Mikulak Reviewed for Zoning Compliance by the , ► A4,( City of Wheat Ridge Planning Division +r�` _l APPROVED BY: DATE: 5/11/2021 COMMENTS: Complies with approved master permits and site plan WSP-20-03 No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. Reviewed by the City of Wheat Ridge Engineering Division APPROVED Jordan Jefferies BY: DATE: 5/14/2021 COMMENTS: A grading certification with ILC or updated CCP required prior to CO F I N liat if lac• APPROVED ari+rwittl_I��r�sr�a r�,�lihi�;:r Mike Theisen 05/17/2021 -.ans ExarTWifi3 Date ii ca�raali n1r. iw a s..m.F a+ a pobvP 0" W* �n.nrgYa,�►s,cvttia.iF�� �iolo� cyirn+is� 11�r,pso►rw� r('nir��lii�.p �RS,troi�w.9a►iotas� oju�. iir rK��Rt u�.oG► YARROW GARDENS STACKED TOWNHOMES I S H E D A R E A P1 FINISHED DO -MORE COVER SHEET MAIN LEVEL 594 SF UPPER LEVEL 540 SF ENTRY LL 96 SF POWDER 43 SF A1.10 1,273 SF UNFINISHED 3-PLEX-A UPPER LEVEL BUILDING PLAN DO MORE 141 SF SPACE 3-PLEX-A BUILDING ELEVATIONS GARAGE 314 SF U O Q 0 455 SIF P2 -E FINISHED CONSTRUCTION MAIN LEVEL 639 SF UPPER LEVEL 671 SF 1,310 SF UNFINISHED 2 -CAR GARAGE 460 SF ENTRY/DO 260 SF MORE SPACE DECK 31 SF ENTRY ML 81 SF 832 SF P3 -E FINISHED MAIN LEVEL 780 SF UPPER LEVEL 732 SF ENTRY LL 88 SF POWDER 44 SF 1,644 SF UNFINISHED 2 -CAR GARAGE 460 SF DO -MORE 188 SF SPACE DECK 30 SF AO 678 SF M1 9 0 __AMEER6_ 914 111k W�k G TYPE 3A BLOCK 3, LOTS 16-1 8 WHEAT RIDGE, COLORADO THRIVE HOME BUILDERS Homes that do more. I N D E X O F D R A W I N G S DRAWING INDEX SHEET NUMBER SHEET NAME AO DO -MORE COVER SHEET G1 CODE ANALYSIS G2 GENERAL NOTES G3 ARCHITECTURAL SITE PLAN A1.01 3-PLEX-A LOWER LEVEL BUILDING PLAN A1.10 3-PLEX-A MAIN LEVEL BUILDING PLAN A1.20 3-PLEX-A UPPER LEVEL BUILDING PLAN A1.30 3-PLEX-A ROOF PLAN A3.01 3-PLEX-A BUILDING ELEVATIONS A3.02 3-PLEX-A BUILDING ELEVATIONS B U I L D I N G A D D R E SS BLOCK 3, LOTS 16-18 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE E S nu 0 0 0 f h rive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 W W W.THRIVEHOMEBUI LDERS.COM - GoddenISudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat o �Q; m �G \oc LU U O Q 0 r~^ v LU L J O ZO wO U W Z lJ 3� 0 V O� LLJ O oe -3: CONSTRUCTION SET ISSUE DATE 7/21/2020 DO -MORE COVER SHEET AO 0 f h rive HOME BUILDERS Homes that do more THRIVE HOME CODE ANALYSIS FIRE-RESISTANT CONSTRUCTION 40 GoddenjSudik -R302.2 TOWNHOUSES: PROJECT DIRECTORY 303.455.4437 www.goddensudik.com -R302.2.1 CONTINUITY: FIRE -RESISTANCE -RATED COMMON WALL SEPARATING EACH UNIT SHALL BE Suite 250 Centennial, CO 80111 APPLICABLE CODES & STANDARD: CONTINUOUS FROM FOUNDATION TO UNDERSIDE OF ROOF SHEATHING AND FIRE -RESISTANCE RATING LU 2018 INTERNATIONAL BUILDING CODE SHALL EXTEND THE FULL LENGTH OF THE COMMON WALL. ARCHITECT CIVIL ENGINEER STRUCTURAL ENGINEER 0 V O W O oe -3: 2018 INTERNATIONAL RESIDENTIAL CODE GoddenlSudik Architects Baseline Engineering EV Studio SET 2018 INTERNATIONAL ENERGY CONSERVATION CODE -R302.2.2.2 PARAPETS... EXCEPTION: PARAPETS WILL NOT BE REQUIRED... WHEN THE ROOF IS COVERED WITH 5975 S. Quebec St., Suite 250 1950 Ford Street 1117 Cherokee Street 2018 INTERNATIONAL MECHANICAL CODE A MINIMUM CLASS C ROOF COVERING, AND THE ROOF DECKING OR SHEATHING IS OF NONCOMBUSTIBLE Centennial, CO 80111 Golden, CO 80401 Denver, CO 80204 303.455.4437 303.940.9966 303.670.7242 2018 INTERNATIONAL PLUMBING CODE MATERIALS OR APPROVED FIRE -RETARDANT -TREATED WOOD FOR A DISTANCE OF 4 FEET ON EACH SIDE OF Contact: Paul Brady Contact: Noah Nemmers Contact: Ross Maxwell 2018 INTERNATIONAL FIRE CODE THE COMMON WALL. 2018 INTERNATIONAL FUEL GAS CODE 2017 NATIONAL ELECTRIC CODE -R302.2.4 STRUCTURAL INDEPENDENCE: OWNER LANDSCAPE ARCHITECT EXCEPTION 1. FOUNDATIONS SUPPORTING EXTERIOR WALLS OR COMMON WALLS. Thrive Home Builders Redland OCCUPANCY: TOWNHOUSE EXCEPTION 2. STRUCTURAL ROOF AND WALL SHEATHING FROM EACH UNIT MAY FASTEN TO THE 1875 Lawrence Street, Suite 900 1500 West Canal Court PER THE INTERNATIONAL BUILDING CODE EXCEPTION (101.2) DETACHED ONE- AND TWO-FAMILY DWELLING COMMON WALL FRAMING. Denver, CO 80202 Littleton, CO 80120 303.707.4439 720.283.6783 Gl AND MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES) NOT MORE THAN THREE STORIES ABOVE GRADE EXCEPTION 3. NONSTRUCTURAL WALL AND ROOF COVERINGS Contact: Eric Sung Contact: Susan Wade PLANE IN HEIGHT WITH A SEPARATE MEANS OF EGRESS AND THEIR ACCESSORY STRUCTURES SHALL COMPLY EXCEPTION 4. FLASHING AT TERMINATION OF ROOF COVERING OVER COMMON WALL WITH THE INTERNATIONAL RESIDENTIAL CODE. -R302.4.1 THROUGH PENETRATIONS: THROUGH PENETRATIONS OF FIRE -RESISTANCE -RATED WALL HEIGHT AND NUMBER OF STORIES: ASSEMBLIES SHALL COMPLY WITH SECTION R302.4.1.1 OR R302.4.1.2 STORIES: 3 STORIES (MAX) GARAGES: HEIGHT: 32 FT MAX OR PER VARIANCE APPROVAL -R302.5.1 OPENING PROTECTION: DOORS BETWEEN GARAGE AND RESIDENCE SHALL BE MINIMUM OF 1 3/8" THICK SOLID WOOD DOORS, SOLID OR HONEYCOMB CORE STEEL DOORS OR 20 MINUTE FIRE -RATED 2018 INTERNATIONAL RESIDENTIAL CODE PROVISIONS DOORS EQUIPPED WITH A SELF-CLOSING DEVICE. R302.1 CONSTRUCTION, PROJECTIONS, OPENINGS AND PENETRATIONS OF EXTERIOR WALLS OF -R302.5.2 DUCT PENETRATION: DUCTS IN THE GARAGE AND PENETRATING THE WALLS OR CEILING DWELLINGS AND ACCESSORY BUILDINGS SHALL COMPLY WITH TABLE R302.1 SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM No. 26 GAGE EXCEPTION 1. WALLS, PROJECTIONS, OPENINGS OR PENETRATIONS IN WALLS SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE PERPENDICULAR TO THE LINE USED TO DETERMINE THE FIRE SEPARATION DISTANCE R302.6 DWELLING/GARAGE FIRE SEPARATION: PER TABLE R302.6 - DOES NOT APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL TABLE R302.1(1) EXTERIOR WALL TABLE R302.6 DWELLING/GARAGE SEPARATION MINIMUM FIRE -RESISTANCE MINIMUM FIRE SEPARATION EXTERIOR ELEMENT RATING DISTANCE SEPARATION MATERIAL FROM THE RESIDENCES AND ATTICS NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT APPLIED TO FIRE -RESISTANCE RATED 1 HOUR TESTED 0 FEET ASTM E 119 OR UL 263 THE GARAGE SIDE WALLS NOT FIRE -RESISTANCE RATED 0 HOURS >_ 5 FEET FROM ALL HABITABLE ROOMS ABOVE THE NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIVALENT NOT ALLOWED N/A < 2 FEET GARAGE FIRE -RESISTANCE RATED 1 HOUR ON THE > 2 FEET < 5 FEET STRUCTURE(S) SUPPORTING FLOOR/CEILING PROJECTIONS UNDERSIDE ASSEMBLIES USED FOR SEPARATION NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT REQUIRED BY THIS SECTION NOT FIRE -RESISTANCE RATED 0 HOURS >_ 5 FEET NOT ALLOWED N/A < 3 FEET GARAGES LOCATED LESS THAN 3 FEET NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT APPLIED TO OPENINGS IN WALLS 25% MAX OF WALL AREA 0 HOURS 3 FEET FROM A DWELLING UNIT ON THE SAME LOT THE INTERIOR SIDE OF EXTERIOR WALLS THAT ARE WITHIN THIS AREA UNLIMITED 0 HOURS 5 FEET COMPLY W/ R302.4 < 3 FEET LIGHT, VENTILATION AND HEATING PENETRATIONS ALL NONE REQUIRED 3 FEET -ALL APPLICABLE ROOMS WILL COMPLY WITH REQUIREMENTS IN SECTION R303. -GARAGES WILL NOT BE MECHANICALLY HEATED. MEANS OF EGRESS TABLE R302.1(2) EXTERIOR WALL - DWELLINGS WITH FIRE SPRINKLERS -SEPARATE MEANS OF EGRESS WILL BE PROVIDED FOR EACH UNIT. MINIMUM FIRE -RESISTANCE MINIMUM FIRE SEPARATION EXTERIOR ELEMENT RATING DISTANCE -AUTOMATIC SPRINKLER SYSTEM WILL ONLY BE INSTALLED IN SPECIFIC UNITS AS NOTED ON SHEET G3. 1 HOUR TESTED FIRE -RESISTANCE RATED 0 FEET ASTM E 119 OR UL 263 -FIRE SPRINKLER SYSTEM SHALL BE DESIGNED & INSTALLED IN ACCORDANCE WITH SECTION P2904 WALLS OR NFPA NOT FIRE -RESISTANCE RATED 0 HOURS 3 FEET D. CA/ACCESSIBILITY NOT ALLOWED N/A < 2 FEET PER FAIR HOUSING ACT: MULTISTORY DWELLING UNITS ARE NOT COVERED BY THE GUIDELINES WITHOUT 1 HOUR ON THE PROJECTIONS FIRE -RESISTANCE RATED UNDERSIDE 2 FEET ONE OR MORE ELEVATORS. -R320.1 SCOPE: WHERE THERE ARE FOUR OR MORE DWELLING UNITS IN A SINGLE STRUCTURE, THE NOT FIRE -RESISTANCE RATED 0 HOURS 3 FEET PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL APPLY. NOT ALLOWED N/A < 3 FEET OPENINGS IN WALLS -IBC 1 107.6.3 GROUP R-3: WHERE THERE ARE FOUR OR MORE DWELLING UNITS IN A SINGLE STRUCTURE, UNLIMITED 0 HOURS 3 FEET EVERY DWELLING UNIT SHALL BE A TYPE B UNIT. -R1 107.7.2 MULTISTORY UNITS: A MULTISTORY DWELLING UNITY WHICH IS NOT PROVIDED WITH ELEVATOR COMPLY W/ R302.4 < 3 FEET SERVICE IS NOT REQUIRED TO BE A TYPE B UNIT. PENETRATIONS ALL NONE REQUIRED 3 FEET DEFERRED SUBMITTALS: FIRE SPRINKLERS (DEFERRED SUBMITTAL UNDER SEPARATE PERMIT) STRUCTURAL FOUNDATION PLANS WILL BE SUBMITTED AT INDIVIDUAL LOT SUBMITTALS. 0 f h rive HOME BUILDERS Homes that do more THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM 40 GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 0E m �G \oc LU U O 0 V) LU L O ZO wO U ��Wnn V oe Z 0 V O W O oe -3: CONSTRUCTION SET ISSUE DATE 7/21/2020 CODE ANALYSIS Gl GENERAL NOTES ROOF NOTES FIRE SEPARATION NOTES 1 . CODES HAVING JURISDICTION SHALL BE STRICTLY OBSERVED IN THE CONSTRUCTION OF 1 . ALL ROOF TRUSSES TO BE DESIGNED AND FABRICATED UNDER THE SUPERVISION OF A 1 . OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING THE PROJECT. ALL APPLICABLE STATE, COUNTY, AND CITY REQUIREMENTS REGARDING COLORADO LICENSED STRUCTURAL ENGINEER. PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND THE BUILDING, ZONING, ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE CODES SHALL BE 2. PROVIDE ROOF VENTS AND/OR SOFFIT VENTS AS REQUIRED PER IRC. SEE ROOF VENT RESIDENCE SHALL BE EQUIPPED WITH A SELF-CLOSING, SELF -LATCHING SOLID WOOD VERIFIED BY THE SUBCONTRACTORS BEFORE COMMENCEMENT OF CONSTRUCTION. ANY CALCULATIONS FOR "NET FREE AREA REQUIRED". DOOR NOT LESS THAN 1-3/8" IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOOR DISCREPANCIES BETWEEN THE CODE REQUIREMENT AND THE DRAWINGS SHALL BE 3. CRICKET AND SADDLES SHALL BE INSTALLED IN REQUIRED LOCATIONS PER IRC. NOT LESS THAN 1-3/8" THICK, OR 20 -MINUTE FIRE -RATED DOORS. (IRC) REPORTED TO THE BUILDER IMMEDIATELY. 4. INSTALL CONTINUOUS SOFFIT VENTS WITH OVERHANGS UNDER 24 INCHES AND SOLID 2. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC SPACE BY NOT 2. CONTACT THE BUILDER FOR CLARIFICATION OF ANY DISCREPANCIES AND/OR ERRORS SOFFIT BOARDS WITH UNDEREAVE VENTS WITH OVERHANGS OVER 24 INCHES. LESS THAN 5/8" TYPE 'X' GYPSUM BOARD APPLIED TO THE GARAGE SIDE. WHERE THE FOUND IN THE CONTRACT DOCUMENTS. ANY CHANGES TO THE CONTRACT DOCUMENTS 5. ICE AND WATER SHIELD TO BE INSTALLED PER IRC & BUILDING SPECIFICATIONS. SEPARATION IS A HORIZONTAL THE GYPSUM BOARD SHALL BE ATTACHED TO FRAMING SHALL BE REVIEWED AND APPROVED BY THE BUILDER PRIOR TO ANY CONSTRUCTION. 6. VALLEYS: CENTER A 36" WIDE STRIP OF SELF -ADHERED ICE AND WATER SHIELD IN THE VALLEY. MEMBER SPACED NO MORE THAN 16 INCHES ON CENTER AND THE STRUCTURE 3. ALL PRODUCTS SHALL BE INSTALLED PER MANUFACTURER'S INSTALLATION GUIDELINES ICE AND WATER SHIELD SHALL BE TIGHT IN THE VALLEY, WITHOUT CREASES OR WRINKLES. SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 5/8" TYPE 'X' AND/OR BUILDER DETAILS. CONTACT BUILDER WITH ANY DISCREPANCIES BETWEEN MFR'S INSTALL ROOF UNDERLAYMENT TO THE ROOF AND OVERLAP ICE & WATER SHIELD STRIP BY 6" GYPSUM BOARD OR EQUIVALENT. (IRC) AROUND STRUCTURAL ELEMENTS PROVIDE 5/8" GUIDELINES AND BUILDER PROVIDED DETAILS PRIOR TO INSTALLATION. MINIMUM. INSTALL SHINGLES IN CLOSED OR WOVEN VALLEY PER SHINGLE MANUFACTURER'S TYPE 'X' GYPSUM BOARD - TAPE AND FINISH. 4. CONTRACTOR AND APPLICABLE TRADES WORKING ON THE JOB SHALL CONSULT WITH AND SPECIFICATIONS 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING FOLLOW PREPARED SOILS REPORT RECOMMENDATIONS. 7. GENERAL UNDERLAYMENT REQUIREMENTS PER IRC AND ROOFING MANUFACTURER'S THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE 5. SEE STRUCTURAL ENGINEER'S SITE SPECIFIC FOUNDATION PLANS FOR FINAL CONSTRUCTION SPECIFICATION: (0.48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS SPECIFICATIONS. 7.1. FOR 2:12 UP TO 4:12 ROOF, PROVIDE 2 LAYERS OF BUILDER APPROVED INTO THE GARAGE. 6. CONTRACTOR TO COORDINATE TOP OF FOUNDATION WALL ELEVATIONS WITH UNDERLAYMENT. 4. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE INFORMATION INDICATED ON THESE DRAWINGS, STRUCTURAL ENGINEER'S FOUNDATION 7.2. FOR 4:12 AND GREATER, PROVIDE ONE LAYER OF BUILDER APPROVED UNDERLAYMENT. AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. (IRC) PLANS AND FINAL SITE GRADING. 8. PROVIDE DOWNSPOUTS, PER BUILDER SPECIFICATIONS, W/ ADJUSTABLE EXTENDERS TO 5. AT MECHANICAL FLUES PROVIDE DRAFT STOP AT FLOOR LEVELS, VERIFY CLEARANCE WITH 7. PROVIDE POSITIVE DRAINAGE AWAY FROM FOUNDATION PER SOILS REPORT CARRY WATER MIN. 5-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT OR MANUFACTURER, MECHANICAL ENGINEER AND LOCAL CODES. RECOMMENDATIONS OR A MINIMUM OF 10% AWAY FROM FOUNDATION FOR THE FIRST 10 PER LOCAL CODES. WHERE APPLICABLE, REFER TO CIVIL DRAWINGS FOR LOCATION OF AND 6. FLOOR ASSEMBLIES THAT ARE NOT REQUIRED BY CODE TO BE FIRE -RESISTANCE RATED, FEET. IMPERVIOUS SURFACES MAY BE SLOPE 2.5% MINIMUM AWAY FROM THE STRUCTURE CONNECTION TO THE STORM DRAIN SYSTEM. SHALL BE PROVIDED WITH A 1/2" GYPSUM WALL BOARD MEMBRANE, 5/8" WOOD FOR THE FIRST 10 FEET. STRUCTURAL PANEL MEMBRANE OR EQUIVALENT ON THE UNDERSIDE OF THE FLOOR 8. PROVIDE DAMP PROOFING ON EXTERIOR FACE OF ALL FOUNDATION WALL PER BUILDER OPENING NOTES FRAMING MEMBER. PENETRATIONS OR OPENINGS FOR DUCTS, VENTS, ELECTRICAL SPECIFICATION - FOR SINGLE FAMILY DETACHED ONLY. 1 . PROVIDE TEMPERED GLAZING IN HAZARDOUS LOCATIONS PER IRC OUTLETS, LIGHTING, DEVICES, LUMINARIES, WIRES, SPEAKERS, DRAINAGE, PIPING AND 9. PER IRC, PROVIDE 4" MIN. GRAVEL BASE OR APPROVED EQUAL UNDER CONCRETE SLAB ON 2. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOT LESS THAN SIMILAR OPENINGS OR PENETRATIONS SHALL BE PERMITTED. GRADE WITH A 6" MIN. POLYETHYLENE OR APPROVED VAPOR BARRIER WITH JOINTS LAPPED ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENINGS. EXCEPTIONS: NOT LESS THAN 6" BETWEEN GRAVEL BASE AND SLAB - FOR SINGLE FAMILY DETACHED. 3. EGRESS WINDOWS (IRC): 6.1. FLOOR ASSEMBLIES PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM. 10. PROVIDE MINIMUM CLEARANCES FOR ALL EXTERIOR WALL MATERIALS TO TOP OF GRADE PER 3.1 . EGRESS WINDOWS TO HAVE A SILL HEIGHT OF 24" MINIMUM AND 44" MAXIMUM ABOVE 6.2. FLOOR ASSEMBLIES LOCATED DIRECTLY OVER A CRAWL SPACE NOT INTENDED FOR LOCAL CODES OR A MINIMUM OF 8" (4" FOR MASONRY VENEERS). FINISHED FLOOR. STORAGE OR FUEL -FIRED APPLIANCES. 1 1 . ALL DIMENSIONS ARE TO FACE OF FOUNDATION OR ROUGH FACE OF STUDS UNLESS 3.2. SHALL HAVE 5.7 SQUARE FEET OF OPEN AREA. GRADE FLOOR MINIMUMALL 6.3. AGGREGATE AREA OF THE UNPROTECTED PORTION DOES NOT EXCEED 80 S.F. & INDICATED OR NOTED OTHERWISE. ALL MASONRY DIMENSIONS INDICATED ARE NOMINAL OPENINGS SHALL HAVE A MINIMUM OF 5 SQUARE FEET OF NET OPEN AREA. FIREBLOCKING IS INSTALLED ALONG THE PERIMETER OF THE UNPROTECTED PORTION DIMENSIONS. CONTACT THE BUILDER FOR CLARIFCATION WITH ANY DIMENSIONING ISSUES 3.3. NET CLEAR HEIGHT SHALL BE 24" MINIMUM AND NET CLEAR WIDTH SHALL BE 20" TO SEPARATE THE AREA FROM THE REMAINDER OF THE FLOOR ASSEMBLY. OR CONFLICTS. DO NOT SCALE. MINIMUM. 6.4. WOOD FLOOR ASSEMBLIES USING DIMENSION LUMBER OR STRUCTURAL COMPOSITE 12. THICKNESS OF INTERIOR WALL FRAMING IS 3 1/2" UNLESS NOTED OTHERWISE. 4. EGRESS WINDOW WELLS MUST ALLOW FULL OPERATION OF WINDOW HAVE A MINIMUM LUMBER EQUAL TO OR GREATER THAN 2X10 NOMINAL DIMENSION, OR OTHER 13. TYPICAL THICKNESS OF 2X6 EXTERIOR WALL FRAMING IS 5 1/2" UNLESS NOTED CLEAR AREA OF 9 SQUARE FEET AND A MINIMUM HORIZONTAL PROJECTION AND WIDTH OF APPROVED FLOOR ASSEMBLIES DEMONSTRATING EQUIVALENT FIRE PERFORMANCE. OTHERWISE. 36 INCHES. IF WINDOW WELL IS OVER 44 INCHES DEEP, PERMANENT STAIRS OR LADDER 7. PROVIDE FIRE -RATED EAVE PER DETAIL AS REQUIRED PER CODE -VERIFY W/ PLOT PLAN AND 14. DOOR &WINDOW CALLOUTS ARE GENERIC/NOMINAL DIMENSIONS. ACTUAL ROUGH MUST BE PROVIDED WHICH DOES NOT PREVENT OPERATION OF THE WINDOW OR FIELD CONDITIONS. OPENINGS PER MANUFACTURER'S SPECS. ENCROACH MORE THAN 6 INCHES INTO THE CLEAR AREA. (IRC) 15. ALL ANGLES ARE 450 UNLESS NOTED OTHERWISE FIRE SPRINKLER NOTES 16. ALL DOOR & WINDOW DIMENSIONS ARE SHOWN TO CENTERLINE OF R.O. UNO PLUMBING NOTES 1. AN AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN ONE- AND TWO- FAMILY 17. PLATFORM FRAME ALL WALLS TO UNDERSIDE OF BOTTOM CHORDS OF TRUSS OR JOIST. 1 . VERIFY WITH LOCAL MUNICIPALITY &INSTALL WATER -HAMMER ARRESTORS AS NECESSARY TO DWELLINGS UNLESS EXEMPTED BY LOCAL MUNICIPALITY. 18. FRAMING CONTRACTOR SHALL COORDINATE WITH THE OWNER AND ALL SERVICE LINES FOR WASHER BOX, DISHWASHER AND ICE -MAKER. WATER -HAMMER ARRESTORS 2. DESIGN &INSTALL AUTOMATIC FIRE SPRINKLER SYSTEMS PER IRC AND LOCAL CODES. SUBCONTRACTORS TO DETERMINE THE LOCATION OF ALL FIXTURES, APPLIED TREATMENTS, SHALL INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION EQUIPMENT, HARDWARE ITEMS, ETC., AND PROVIDE SOLID STRUCTURAL BLOCKING AND/OR INSTRUCTIONS. C CTIONS. IECC 2018 COMPLIANCE NOTES EXTRA FRAMING NECESSARY FOR SAFE AND SOUND ANCHORAGE AND/OR SUPPORT. 2. SUMP PIT &PUMP TO BE INSTALLED PER LOCAL CODES (IRC) AND SEALED WITH GAS-TIGHT SIMULATED PERFORMANCE ALTERNATIVE METHOD 19. PROVIDE VERTICAL AND HORIZONTAL FIREBLOCKING/DRAFTSTOPS PER LOCAL CODES REMOVABLE COVER. FIELD VERIFY LOCATION OF PIT. 1 . INSULATION - SEE SCHEDULE. 20. HABITABLE ROOMS, HALLWAYS, CORRIDORS, BATHROOMS, TOILET ROOMS, LAUNDRY 3. PROVIDE COMBUSTION AIR PER SPECIFICATION AND LOCAL CODES (IRC) TO FURNACE AND 2. WINDOWS - LOW -E, U<0.30 MINIMUM. ROOMS AND BASEMENTS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET. THE HOT WATER HEATER. 3. HEATING - FUEL -FIRED AIR DISTRIBUTION, NATURAL GAS, 92.1 AFUE MINIMUM. REQUIRED HEIGHT SHALL BE MEASURED FROM THE FINISH FLOOR TO THE LOWEST 4. WATER CLOSETS AND LAVATORIES SHALL BE SET 15" FROM ITS CENTER TO ANY SIDE WALL, 4. COOLING -ELECTRIC AIR CONDITIONING UNIT, 13.0 SEER MINIMUM. PROJECTION FROM THE CEILING. (IRC) PARTITION OR VANITIES AND MAINTAIN 30" MINIMUM CENTER -TO -CENTER BETWEEN 5. WATER HEATING - TANKLESS HOT WATER SYSTEM WITH BUILT-IN RE -CIRCULATION PUMP. 21. CEILINGS IN BASEMENTS WITHOUT HABITABLE SPACES MAY PROJECT TO WITHIN 6 FEET, 8 ADJACENT FIXTURES. 0.97 EF. INCHES OF THE FINISHED FLOOR; AND BEAMS, GIRDERS, DUCTS OR OTHER OBSTRUCTIONS 5. MAINTAIN 21" MINIMUM CLEARANCES IN FRONT OF WATER CLOSETS AND LAVATORIES. 6. PROGRAMMABLE THERMOSTAT STANDARD - ONE PER HEATING/COOLING SYSTEM. MAY PROJECT TO WITHING 6 FEET, 4 INCHES OF THE FINISHED FLOOR. (IRC) 7. DUCT SEALING - LESS THAN OR EQUAL TO 4 CFM/100 SF FOR 2 RETURNS & 6CFM FOR 3 22. SHOWER AND TUB/SHOWER WALLS SHALL BE INSTALLED WITH BACKING PER BUILDER RADON MITIGATION NOTES RETURNS SPECIFICATION & FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT OF 6'-0" (IRC) 1 . 3" MIN. VERTICAL VENT PIPE CONNECTED TO 3" MIN. UNDER SLAB PERFORATED PIPE IN 4" 8. PER SECTION N1 101.14 (R401.3) (MANDATORY) A PERMANENT CERTIFICATE SHALL BE 23. VENT ALL EXHAUST FANS TO EXTERIOR. PROVIDE RAIN CAPS AND FLASHING AS REQUIRED. MIN. GRAVEL BED (BY OTHERS) AND RUN THROUGH HOUSE'S CONDITION SPACE AND ROOF COMPLETED BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL AND POSTED ON A 24. PROVIDE MECHANICAL VENTILATION PER CODE IN BATHROOMS CONTAINING A BATHTUB & FLASH ALL PENETRATIONS. INSTALL PER EPA'S GUIDANCE DOCUMENT FOR RADON OR PER WALL IN THE SPACE WHERE THE FURNACE IS LOCATED A UTILITY ROOM OR AN APPROVED ' AND/OR SHOWER, WATER CLOSET COMPARTMENTS AND SIMILAR ROOMS BUILDER'S GUIDE TO COLD CLIMATES. - AT SLAB ON GRADE LOCATION INSIDE THE BUILDING. THAT DO NOT HAVE ACCESS TO NATURAL VENTILATION. 2 3" MIN. VERTICAL VENT PIPE CONNECTED TO 3" MIN. UNDER SLAB BETWEEN VOID MATERIAL 9. THE AREA -WEIGHTED AVERAGE MAXIMUM FENESTRATION U -FACTOR PERMITTED USING 25. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF AND RUN THROUGH HOUSE'S CONDITION SPACE AND ROOF & FLASH ALL PENETRATIONS. TRADE-OFFS FROM SECTION N1 102.5 SHALL BE 0.48 IN CLIMATE ZONES 4 TREADS OR FLIGHT WITH FOUR OR MORE RISERS. (IRC) HANDRAIL HEIGHT, MEASURED INSTALL PER EPA'S GUIDANCE DOCUMENT FOR RADON OR PER BUILDER'S GUIDE TO COLD AND 5, AND 0.75 IN CLIMATE ZONES 4 THROUGH 8 FOR SKYLIGHTS. VERTICALLY FROM THE SLIPED PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE CLIMATES. - AT STRUCTURAL SLAB ON VOID 10. DUCTS, AIR HANDLERS AND FILTER BOXES SHALL BE SEALED. OF RAMP SLIPE, SHALL BE NOT LESS THAN 34" AND NOT MORE THAN 38". (IRC) ALL REQUIRED 3. INSTALL 6 -MIL MIN. POLYETHYLENE VAPOR BARRIER OR EQUAL ON TOP OF 4" MIN. GRAVEL 1 1 . PER SECTION N1 104.1, NOT LESS THAN 75% OF THE LAMPS IN PERMANENTLY INSTALLED HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE FLIGHT FROM A POINT BED PRIOR CASTING THE SLAB. LAP BARRIER 12" MIN. &FIT CLOSELY AROUND ANY PIPE LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS OR NOT LESS THAN 75% OF THE DIRECTLY ABOVE THE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE PE OR OTHER PENETRATIONS. 4. SEAL ALL PENETRATIONS IN SLAB WITH POLYURETHANE CAULK OR EQUIVALENT SEALANT PER PERMANENTLY INSTALLED LIGHT FIXTURES SHALL CONTAIN ONLY HIGH -EFFICACY LAMPS. LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN MFR'S SPECS. 12. CLASS 1, II OR III VAPOR RETARDERS ARE REQUIRED ON THE INTERIOR SIDE OF FRAME NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A 5. PROVIDE ELECTRICAL POWER IN THE ATTIC WITHIN & OF THE RADON VENT PIPE. RADON FAN WALLS IN CLIMATE ZONE 5. THE FOLLOWING SHALL BE DEEMED TO MEET THE CLASS SPACE OF NOT LESS THAN 1 1/2" BETWEEN THE WALL AND HTE HANDRAILS. (IRC) THE SPECIFIED: HANDRAIL GRIP SIZE IS REQUIRED TO COMPLY WITH IRC. PER SPECIFICATIONS & INSTALLED PER MFR'S SPECIFICATIONS. 12.1. CLASS III: LATEX OR ENAMEL PAINT, PER IRC 26. PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCATED MORE THAN 30" ABOVE THE INSULATION SCHEDULE 13. ALL CRAWLSPACES, IF APPLICABLE, ARE CONDITIONED. FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDES FOUNDATION WALL - UNFINISHED ................................................ R-5 MIN. RIGID FOAM AT 14. SEE PROVIDED "PROJECTED" COMPLIANCE REPORT FROM ENERGY LOGIC. A FINAL OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW EXTERIOR FACE "CONFIRMED" COMPLIANCE REPORT FROM ENERGY LOGIC SHALL BE PROVIDED PRIOR TO A SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSE 2x4 STUD WALL............................................................................... R-13 MIN. PER CERTIFICATE OF OCCUPANCY. OF THE TREADS. (IRC) BUILDER SPECS 27. OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTAL PATTERNS SPACED 2X6 STUD WALL............................................................................... R-20 MIN. PER AIR SEALING NOTES SUCH THAT A 4" SPHERE CANNOT PASS THROUGH (IRC) BUILDER SPECS 1 . DRYWALL GASKET SYSTEM PER BUILDER SPEC AT ALL TOP PLATES ADJOINING AN ATTIC SPACE 28. IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION, AN ATTIC ACCESS ATTIC............................................................................................... R-50 MIN. PER AND AT ALL SEAMS, GAPS AND CRACKS ON GARAGE SEPARATION WALL, INCLUDING OSB OPENING SHALL BE PROVIDED TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET AND HAVE A BUILDER SPECS JUNCTIONS AT TOP PLATE, BOTTOM PLATE AND CORNERS. VERTICAL HEIGHT OF 30" OR GREATER. THE ROUGH -FRAMED OPENING SHALL NOT BE LESS CANTILEVERED FLOORS................................................................... BLOW FULL W/ 2. FOAM SEALANT AT SILLS, GAPS IN FRAMING, OUTLETS ON EXTERIOR WALLS, PENETRATIONS THAN 22" X 30" AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE INSULATION PER BUILDER INTO ATTIC. 2ND AND 3RD SUBFLOOR RIM (TOP AND BOTTOM) AND AT MAIN FLOOR LOCATION. A 30" MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE SPECS WHERE SILL PLATE MEETS THE CONCRETE FOUNDATION. PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE IMC FOR ACCESS RIM JOISTS....................................................................................... 2" CLOSED CELL 3. ALL WINDOW & DOOR FRAMES WIILL BE SEALED WITH A CONTINUOUS BEAD OF REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTICS. (IRC) SPRAY FOAM W/ R-19 BATT NON -EXPANDING FOAM (DOW GREAT STUFF OR EQUIVALENT). 29. PROVIDE WALL AND ROOF FLASHING AT LOCATIONS PER MANUFACTURER'S SPECIFICS, IRC GARAGE CEILING (OPTIONAL).......................................................... R-36 MIN. PER BUILDER AND LOCAL CODES. INSTALL PER BEST PRACTICES, MANUFACTURER'S GUIDELINES OR PER SPECS BUILDER SPECIFICATIONS. CONSULT BUILDER PRIOR TO INSTALL REGARDING ANY 2x4 GARAGE WALL (OPTIONAL)........................................................ R-13 MIN. PER BUILDER QUESTIONS OR CONFLICTS. SPECS 30. OPENINGS AT ELECTRICAL BOXES AND OTHER SIMILAR BOXES EMPLOYING A FLUSH TYPE 2x6 GARAGE WALL (OPTIONAL)........................................................ R-20 MIN. PER BUILDER COVER OR FACEPLATE SHALL BE MADE SO THAT THERE ARE NO GAPS GREATER THAN 1/81, SPECS AROUND THE EDGE OF THE BOX (REPAIR AS NEEDED) 31. VERIFY ALL LOCATIONS, SPANS AND SPACING OF BEAMS, BEARING WALLS, POINT LOADS, JOISTS, RAFTERS AND TRUSSES WITH STRUCTURAL ENGINEER'S DRAWINGS AND CALCULATIONS. 0 f h rive HOME BUILDERS Homes that do more THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM 40 GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 0E �G \oc LU U O 0 V) LU L O ZO wO U 7 �Wn 0e L V 0 V O W O oe -3: CONSTRUCTION SET ISSUE DATE 7/21/2020 GENERAL NOTES G2 T POINTS REQUIRED YI-I 89 (TOTAL) _ 43 VISITABLE DWELLING UNIT 43 1 43 N 1 HOUR TESTED Y4 -EA 43 43 0E m 263 OR IBC SECTION 0 FEET WALLS 703.3 EXPOSURE U O C) Y1 -IA N CO Ww BLDG 3 FEET Y2 -IA NOT ALLOWED U)a PROJECTIONS 1 HOUR UNDERSIDE BLOCK 5, LOTS 19-24 0 HOURS BLDG TYPE f' 30 �� < 3 FEET BLOCK 4, LOTS 6-1 �O Y21 WALLS c� Y2-1 Y4 -E w Q b. O} a° o UNLIMITED (0 HRS) 3 FEET io o YI-I a° ° rn Y4_W a 0 G3 /Y4 -EA w BLDG TYPE 5A BLOCK 4, LOTS 1-5 Y2-1 N Y4 -E ° o Iw LU J U 0 M U) LU LU LU U 0 M U) LU LU WEST 43RD CIRCLE WEST 43RD CIRCLE --X \ \ ARCHITECTURAL SITE PLAN 1 if = 30'-0" WEST 43RD PLACE WEST 43RD PLACE 30Vjd 4HEb 1S3M 30Vjd 4HEb 1S3M 30Vjd 4HEb 1S3M u a a u 10'-6" 10'-6" — — Y4 -W Y1 -I Y1 -I _Y2 -E Y2 -E Y1 -I Y1 -I Y4 -W Y1 -I Y2 -I Y2 -I Y4 -E— Y4 -E Y2- EE BLDG TYPE 4B BLDG TYPE 4B BLDG TYPE 5A 8 BLOCK 6, LOTS 5-8 5 6 � BLOCK 6, LOTS 1-4 1,BLOCK 5, LOTS 5-9 � � 5 L 9 E Z 6 g 9 5 — L I El BLDG TYPE 4BLDG TYPE 4B% BLOCK 6, LOTS 9-12 BLOCK 6, LOTS 13-16 Y4 -EA Y1 -IA 1 -IAS Y2 -EA Y2-EA� Y1 -IA Y1 -IA Y4 -WA �oN RETS u WEST 42ND AVENUE R.O.W. VARIES WEST 42ND AVENUE R.O.W. VARIES WEST 43RD PLACE 30V_jd 4HEb 1S3M T 1 E Y1 -I Y1 -I —Y2 -E BLDG TYPE 4B BLOCK 5, LOTS 1-4 E Z i 8'-9" 8'-9" 11 16 17 18 10 12 13 14 15 BLDG TYPE 5A BLDG TYPE 4B ° BLOCK 5, LOTS 10-14 I BLOCK 5, LOTS 15-18 Y4 -E Y1-1 Y2-1 Y2-1 Y4 -E I Y2 -E Y1-1 Y1-1 Y2 -W WEST 42ND AVENUE R.O.W. VARIES q° WEST 42ND AVENUE R.O.W. VARIES W. 42ND AVE. 1 I10 Y2 -E Y2 -I M BLDG TYPE 4A BLOCK 1, LOTS 1-4 Y2-1 9 Y4 -W 30V4d 4HEb 1S3M 30V_jd 4HEb 1S3M / V N Y4 W Q� ,moo° S3 RiVA ' W O 11 DnNDAV aNZb 1SDM N SITE PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • DIMENSIONS TAKE PRECEDENCE OVER DRAWING - DO NOT SCALE! • THE ARCHITECTURAL SITE PLAN IS INCLUDED TO GRAPHICALLY INDICATE APPROXIMATE LOCATIONS OF BUILDINGS, PARKING, AND BUILDING NUMBERS ONLY. • REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR LANDSCAPING, SIDEWALKS, MONUMENT, AND FENCE DESIGN. • REFER TO CIVIL ENGINEER'S DRAWINGS FOR HORIZONTAL DIMENSIONAL CONTROLS, GRADING, FINISH FLOOR ELEVATIONS, BUILDING STEPPING, DRAINAGE, UTILITY EASEMENTS, AND ACCESSIBLE ROUTE LOCATIONS AND DETAILS. • REFER TO MEP ENGINEER'S DRAWINGS FOR THE LOCATIONS OF ALL METERS, PANELS, CLEANOUTS, TRANSFORMERS, AND PARKING LOT AND SITE LIGHTING. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • AN ACCESSIBLE ROUTE SHALL BE PROVIDED CONNECTING ACCESSIBLE BUILDINGS AND ACCESSIBLE SITE FACILITIES PER IBC 2018 SECTION 1107.4. • ALL ACCESSIBLE ROUTES MUST COMPLY WITH ICC/ANSI A117.1-2009 CHAPTER 4. • SLOPES GREATER THAN 1:20 ON ANY OF THE ACCESSIBLE ROUTES SHALL REQUIRE HANDRAILS COMPLYING WITH ICC/ANSI A117.1-2009 SECTION 405 & 505 AND NOT EXCEED A SLOPE OF 1:12. ADA / ACCESSIBILITY NOTES 2018 INTERNATIONAL RESIDENTIAL CODE NON -ELEVATOR, MULTI -STORY UNITS ARE EXEMPT FROM FAIR HOUSING ACT REQUIREMENTS. IRC 2018 SECTION R320 - ACCESSIBILITY R320.1 SCOPE. WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS IN A SINGLE STRUCTURE, THE PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL APPLY. • IBC 2018 CHAPTER 11 -ACCESSIBILITY 1107.6.3 GROUP R-3. IN GROUP R-3 OCCUPANCIES WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS INTENDED TO BE OCCUPIED AS A RESIDENCE IN A SINGLE STRUCTURE, EVERY DWELLING UNIT AND SLEEPING UNIT INTENDED TO BE OCCUPIED AS A RESIDENCE SHALL BE A TYPE 'B' DWELLING UNIT. EXCEPTION: THE NUMBER OF TYPE 'B' UNITS IS PERMITTED TO BE REDUCED IN ACCORDANCE WITH SECTION 1107.7. 1107.7.2 MULTISTORY UNITS. A MULTISTORY DWELLING OR SLEEPING UNIT WHICH IS NOT PROVIDED WITH ELEVATOR SERVICE IS NOT REQUIRED TO BE A TYPE 'B' DWELLING UNIT. COLORADO STANDARDS FOR ACCESSIBLE HOUSING CRS 9-5, ARTICLE 5 REQUIREMENT: TOTAL # OF UNITS POINTS REQUIRED YI-I 89 (TOTAL) 43 43 VISITABLE DWELLING UNIT 43 1 43 N 1 HOUR TESTED www.goddensudik.com TOTAL 43 43 0E m 263 OR IBC SECTION 0 FEET WALLS 703.3 EXPOSURE U O C) r� V V L LU O ZO wO U OeN rW Z V N CO Ww BLDG 3 FEET TYPE 6C - ELEV 2 NOT ALLOWED U)a PROJECTIONS 1 HOUR UNDERSIDE BLOCK 5, LOTS 19-24 0 HOURS 3 FEET NOT ALLOWED < 3 FEET OPENINGS IN �O 3 FEET WALLS c� Y2-1 NOT ALLOWED Q b. O} UNLIMITED (0 HRS) 3 FEET o YI-I a° I rn Y4_W a SITE PLAN ,moo° S3 RiVA ' W O 11 DnNDAV aNZb 1SDM N SITE PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • DIMENSIONS TAKE PRECEDENCE OVER DRAWING - DO NOT SCALE! • THE ARCHITECTURAL SITE PLAN IS INCLUDED TO GRAPHICALLY INDICATE APPROXIMATE LOCATIONS OF BUILDINGS, PARKING, AND BUILDING NUMBERS ONLY. • REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR LANDSCAPING, SIDEWALKS, MONUMENT, AND FENCE DESIGN. • REFER TO CIVIL ENGINEER'S DRAWINGS FOR HORIZONTAL DIMENSIONAL CONTROLS, GRADING, FINISH FLOOR ELEVATIONS, BUILDING STEPPING, DRAINAGE, UTILITY EASEMENTS, AND ACCESSIBLE ROUTE LOCATIONS AND DETAILS. • REFER TO MEP ENGINEER'S DRAWINGS FOR THE LOCATIONS OF ALL METERS, PANELS, CLEANOUTS, TRANSFORMERS, AND PARKING LOT AND SITE LIGHTING. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • AN ACCESSIBLE ROUTE SHALL BE PROVIDED CONNECTING ACCESSIBLE BUILDINGS AND ACCESSIBLE SITE FACILITIES PER IBC 2018 SECTION 1107.4. • ALL ACCESSIBLE ROUTES MUST COMPLY WITH ICC/ANSI A117.1-2009 CHAPTER 4. • SLOPES GREATER THAN 1:20 ON ANY OF THE ACCESSIBLE ROUTES SHALL REQUIRE HANDRAILS COMPLYING WITH ICC/ANSI A117.1-2009 SECTION 405 & 505 AND NOT EXCEED A SLOPE OF 1:12. ADA / ACCESSIBILITY NOTES 2018 INTERNATIONAL RESIDENTIAL CODE NON -ELEVATOR, MULTI -STORY UNITS ARE EXEMPT FROM FAIR HOUSING ACT REQUIREMENTS. IRC 2018 SECTION R320 - ACCESSIBILITY R320.1 SCOPE. WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS IN A SINGLE STRUCTURE, THE PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL APPLY. • IBC 2018 CHAPTER 11 -ACCESSIBILITY 1107.6.3 GROUP R-3. IN GROUP R-3 OCCUPANCIES WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS INTENDED TO BE OCCUPIED AS A RESIDENCE IN A SINGLE STRUCTURE, EVERY DWELLING UNIT AND SLEEPING UNIT INTENDED TO BE OCCUPIED AS A RESIDENCE SHALL BE A TYPE 'B' DWELLING UNIT. EXCEPTION: THE NUMBER OF TYPE 'B' UNITS IS PERMITTED TO BE REDUCED IN ACCORDANCE WITH SECTION 1107.7. 1107.7.2 MULTISTORY UNITS. A MULTISTORY DWELLING OR SLEEPING UNIT WHICH IS NOT PROVIDED WITH ELEVATOR SERVICE IS NOT REQUIRED TO BE A TYPE 'B' DWELLING UNIT. COLORADO STANDARDS FOR ACCESSIBLE HOUSING CRS 9-5, ARTICLE 5 REQUIREMENT: TOTAL # OF UNITS POINTS REQUIRED POINTS PROVIDED 89 (TOTAL) 43 43 ACCESSIBLE UNITS PROVIDED UNIT TYPE # OF UNITS PER CRS 9-5 POINTS/ TOTAL UNIT POINTS PROVIDED VISITABLE DWELLING UNIT 43 1 43 SEE WHAT COULD BE 1 HOUR TESTED www.goddensudik.com TOTAL 43 43 UNIT TYPE LEGEND VISITABLE DWELLING UNIT = SPRINKLERED = • REFER TO SITE AND GRADING PLANS FOR LOCATIONS OF ACCESSIBLE UNITS AND ACCESSIBLE ROUTES. • PER CRS 9-5, ARTICLE 5, A "TYPE B VISITABLE GROUND FLOOR" MEANS A MULTIPLE -STORY DWELLING UNIT WITH AN ACCESSIBLE ENTRANCE AND TOILET FACILITY DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF ANSI A117.1-1998, SECTION 1003 (ADDITIONAL FEATURES PROVIDED IN ACCORDANCE WITH TYPE 'C' VISITABLE UNITS PER ICC/ANSI A117.1-2009, SECTION 1005. RE: ACCESSIBLE NOTES AND DETAILS). IRC 2018 TABLE R302.10 EXTERIOR WALL REQUIREMENTS - DWELLINGS WITH FIRE SPRINKLERS EXTERIOR MINIMUM FIRE MINIMUM FIRE ELEMENT RESISTANCE SEPARATION RATING DISTANCE SEE WHAT COULD BE 1 HOUR TESTED www.goddensudik.com 5975 S. Quebec Street ASTM E 119 OR UL Centennial, CO 80111 0E m 263 OR IBC SECTION 0 FEET WALLS 703.3 EXPOSURE U O C) r� V V L LU O ZO wO U OeN rW Z V OUTSIDE 0 HOURS 3 FEET ISSUE DATE 7/21/2020 NOT ALLOWED < 2 FEET PROJECTIONS 1 HOUR UNDERSIDE 2 FEET 0 HOURS 3 FEET NOT ALLOWED < 3 FEET OPENINGS IN UNLIMITED (0 HRS) 3 FEET WALLS NOT ALLOWED < 3 FEET PENETRATIONS UNLIMITED (0 HRS) 3 FEET FIRE RATED EAVES/WALLS = PROPERTY LINES = n 0 0 w 0 .T 0 U thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 0E m �G \ac �..LJ U O C) r� V V L LU O ZO wO U OeN rW Z V C) V O LLJ O oe CONSTRUCTION SET ISSUE DATE 7/21/2020 ARCHITECTURAL SITE PLAN G3 1 V L 1 1 1L L LOT 18 4-0" LOT 17 LOT 16 1ST LEVEL*SPRINKLERED* *SPRINKLERED* .040) 1/4" = 1'-0" ROOF -SOFFIT SYSTEMS ON GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 BLOCK 3, LOTS 10-12 GENERIC PLOT PLAN ISSUE DATE: 09/10/2020 BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- (REVISION 1: 10/15/2020) ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 23.6 FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER Suite 250 BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S ENlheat o �Q; DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES LOT 12 AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON • TOS = 25.1 EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ • GARAGE SLAB = 24.0 JOINTS. DRAINAGE WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS BLOCK 3, APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. ISSUE DATE 7/21/2020 APPROPRIATE ROOF COVERING. LOT CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR 16 TRUSSES. 17 APPROX. CEILING 18 WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 TYPE - O 4REA SEPARATION WALLS GA FILE NO. ASW GYPSUM WALLBOARD, STEEL H STUDS 2 HOUR FIRE 1004 60 TO 64 PROPRIETARY* STC SOUND TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) n 0 w 0 .Q 0 .o, thrive PLOT PLAN NOTES Homes that do more. BLOCK 3, LOTS 10-12 B U I L D E R S PLOT PLAN ISSUE DATE: 09/10/2020 (REVISION 1: 10/15/2020) LOT 10 SEE WHAT COULD BE • TOS = 24.4 • GARAGE SLAB = 23.6 LOT 11 Suite 250 • TOS = 25.1 ENlheat o �Q; • GARAGE SLAB = 23.8 LOT 12 U • TOS = 25.1 U Q o • GARAGE SLAB = 24.0 POUR 4" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE Q BLOCK 3, LOTS 16-18 ISSUE DATE 7/21/2020 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE 4REA SEPARATION WALLS GA FILE NO. ASW GYPSUM WALLBOARD, STEEL H STUDS 2 HOUR FIRE 1004 60 TO 64 PROPRIETARY* STC SOUND TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) n 0 w 0 .Q 0 .o, thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat o �Q; U ` i U Q o ~L V) w Ln O ZO wO U C) = w 0eZ Q C) (D O w O ry ry Q CONSTRUCTION SET ISSUE DATE 7/21/2020 3-PLEX-A LOWER LEVEL BUILDING PLAN A1,01 P3 -E LOT 18 2ND LEVEL 1/4" = 1'-0" P1-1 LOT 17 *SPRINKLERED* P2 -E LOT 16 *SPRINKLERED* ROOF -SOFFIT SYSTEMS ON GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 BLOCK 3, LOTS 10-12 GENERIC PLOT PLAN ISSUE DATE: 09/10/2020 BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- (REVISION 1: 10/15/2020) ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 23.6 FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER Suite 250 BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S ENlheat o �Q; DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES LOT 12 AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON • TOS = 25.1 EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ • GARAGE SLAB = 24.0 JOINTS. DRAINAGE WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS BLOCK 3, APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. ISSUE DATE 7/21/2020 APPROPRIATE ROOF COVERING. LOT CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR 16 TRUSSES. 17 APPROX. CEILING 18 WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 TYPE - O AREA SEPARATION WALLS GA FILE NO. ASW 1004 PROPRIETARY* GYPSUM WALLBOARD, STEEL H STUDS TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD 2 HOUR FIRE 60 TO 64 STC SOUND THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) n 0 w 0 .Q 0 .o, thrive PLOT PLAN NOTES Homes that do more. BLOCK 3, LOTS 10-12 B U I L D E R S PLOT PLAN ISSUE DATE: 09/10/2020 (REVISION 1: 10/15/2020) LOT 10 SEE WHAT COULD BE • TOS = 24.4 • GARAGE SLAB = 23.6 LOT 11 Suite 250 • TOS = 25.1 ENlheat o �Q; • GARAGE SLAB = 23.8 LOT 12 LU • TOS = 25.1 U Q o • GARAGE SLAB = 24.0 POUR 4" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE Q BLOCK 3, LOTS 16-18 ISSUE DATE 7/21/2020 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE GYPSUM WALLBOARD, STEEL H STUDS TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD 2 HOUR FIRE 60 TO 64 STC SOUND THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) n 0 w 0 .Q 0 .o, thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat o �Q; LU i U Q o ~L V) w Ln O ZO wO U C) = w OeZ Q C) (D O w O ry ry Q CONSTRUCTION SET ISSUE DATE 7/21/2020 3-PLEX-A MAIN LEVEL BUILDING PLAN A1.10 0 M 56'-6" oo 20'-0" 16-6" 20'-0" 19'-10" 2"� I �2" 16-2" 2"� I r2" 19'-10" 0 3RD LEVEL 1/411 = 1'-0" P3 -E LOT 18 P1-1 LOT 17 *SPRINKLERED* P2 -E LOT 16 (*SPRINKLERED)* ROOF -SOFFIT SYSTEMS 0 ON GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE DWELLING LINE SEPARATION WALL SHALL BE CONTINUOUS— ONTINUOUS FROM FOUNDATION TO THE FROM UNDERSIDE OF THE ROOF_ BLOCK 3, LOTS 10-12 0 o O PLOT PLAN ISSUE DATE: 09/10/2020 BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- SHEATHING, TYP., PER IRC 2018 R302.2.1 CONTINUITY== ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 23.6 W/D Suite 250 BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S ENlheat o �Q; DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES F--- OU AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON • TOS = 25.1 EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ • GARAGE SLAB = 24.0 C I DRAINAGE _F BLOCK 3, DD o APPROPRIATE ROOF COVERING. O CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR 16 �O 17 APPROX. CEILING 18 -- - -- 5 PSF FIRE TEST: FM FC 172, 2-25-72; DO O ------- O L ------- C > 00 3-PLEX-A UPPER 00 PLAN A1.20 00 �� 0 EH 0 3RD LEVEL 1/411 = 1'-0" P3 -E LOT 18 P1-1 LOT 17 *SPRINKLERED* P2 -E LOT 16 (*SPRINKLERED)* ROOF -SOFFIT SYSTEMS 0 ON GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 BLOCK 3, LOTS 10-12 GENERIC PLOT PLAN ISSUE DATE: 09/10/2020 BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- (REVISION 1: 10/15/2020) ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 23.6 FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER Suite 250 BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S ENlheat o �Q; DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES LOT 12 AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON • TOS = 25.1 EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ • GARAGE SLAB = 24.0 JOINTS. DRAINAGE WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS BLOCK 3, APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. ISSUE DATE 7/21/2020 APPROPRIATE ROOF COVERING. LOT CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR 16 TRUSSES. 17 APPROX. CEILING 18 WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 TYPE - O 4REA SEPARATION WALLS GA FILE NO. ASW GYPSUM WALLBOARD, STEEL H STUDS 2 HOUR FIRE 1004 60 TO 64 PROPRIETARY* STC SOUND TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) nu 0 w 0 .Q 0 .o, thrive PLOT PLAN NOTES Homes that do more. BLOCK 3, LOTS 10-12 B U I L D E R S PLOT PLAN ISSUE DATE: 09/10/2020 (REVISION 1: 10/15/2020) LOT 10 SEE WHAT COULD BE • TOS = 24.4 • GARAGE SLAB = 23.6 LOT 11 Suite 250 • TOS = 25.1 ENlheat o �Q; • GARAGE SLAB = 23.8 LOT 12 LU • TOS = 25.1 U0 Q o • GARAGE SLAB = 24.0 POUR 4" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE BLOCK 3, LOTS 16-18 ISSUE DATE 7/21/2020 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE 4REA SEPARATION WALLS GA FILE NO. ASW GYPSUM WALLBOARD, STEEL H STUDS 2 HOUR FIRE 1004 60 TO 64 PROPRIETARY* STC SOUND TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) nu 0 w 0 .Q 0 .o, thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat o �Q; �G \oc 0 LU U0 Q o F_L'r) V) LU o zo wO U C) = w oe z c� Q C) (D O w O oe -3:Q CONSTRUCTION SET ISSUE DATE 7/21/2020 3-PLEX-A UPPER LEVEL BUILDING PLAN A1.20 C c c BLOCK 3, LOTS 16-18 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE cc• c.. PLOT PLAN NOTES BLOCK 3, LOTS 10-12 PLOT PLAN ISSUE DATE: 09/10/2020 (REVISION 1: 10/15/2020) LOT 10 • TOS = 24.4 • GARAGE SLAB = 23.6 LOT 11 • TOS = 25.1 • GARAGE SLAB = 23.8 LOT 12 • TOS = 25.1 • GARAGE SLAB = 24.0 POUR 4" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE ROOF VENTING CALCULATIONS P1-1 TOTAL ROOF AREA = 660 SQ. FT. = 95,040 INz REQUIRED VENTILATION: X/300 = 316 INz NET FREE AREA VENTILATION PROVIDED: AT ROOF: 3 VENTS @ 51 INz = 153 INz (48%) AT EAVE: 17 LINEAR FEET @ 10 INz = 170 INz TOTAL PROVIDED: 323 INz P2 -E TOTAL ROOF AREA = 819 SQ. FT. = 117,936 1 N REQUIRED VENTILATION: X/300 = 393 INz NET FREE AREA VENTILATION PROVIDED: AT ROOF: 3 VENTS @ 51 INz = 153 INz (40%) AT EAVE: 25 LINEAR FEET @ 10 INz = 250 INz TOTAL PROVIDED: 403 INz P3 -E TOTAL ROOF AREA = 882 SQ. FT. = 127,008 1 N REQUIRED VENTILATION: X/300 = 423 INz NET FREE AREA VENTILATION PROVIDED: AT ROOF: 4 VENTS @ 51 INz = 204 INz (48%) AT EAVE: 25 LINEAR FEET @ 10 INz = 250 INz TOTAL PROVIDED: 454 INz P3 -E LOT 18 ROOF PLAN 1/4" = 1'-0" P1-1 LOT 17 *SPRINKLERED* P2 -E LOT 16 *SPRINKLERED* ROOF -SOFFIT SYSTEMS r.� ON GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 6-0" $,_D„ 2602 THRIVE HOME GENERIC 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- GoddenjSudik ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. www.goddensudik.com FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER Suite 250 -------------------------------------- OE m DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES o = AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON -------------------------------------- - -- - - - -------------------- LINE OF STUD -- - -- -- -- ---------------------- ------------------- CONSTRUCTION APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. ISSUE DATE 7/21/2020 APPROPRIATE ROOF COVERING. BELOW CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR LINE OF SOFFIT TRUSSES. APPROX. CEILING WEIGHT: VENTS RE: ROOF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 CALCS, TYP. DWELLING UNIT SEPARATION WALL SHALL BE CONTINUOUS FROM THE 3-PLEX-A ROOF PLAN FOUNDATION TO THE UNDERSIDE OF THE ROOF r SHEATHING, TYP., PER IRC N 2018 R302.2.1- CONTINUITY 1 ROOF VENTS, RE: ROOF CALCS El El � � 1 j COORDINATE LOCATION WITH ell ASPHALT SHINGLES PLACEMENT OF SOLAR PANELS, TYP. I I RIDGE I I RIDGE 1. 0.. I ElII O.H. � I I 10'-01, r - -------------b ----- J O.H. 1 = O o ao O.H. Via° ` II II _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J _ a, L ----------------------- O 2 ....................... N O ...................................... N O P3 -E LOT 18 ROOF PLAN 1/4" = 1'-0" P1-1 LOT 17 *SPRINKLERED* P2 -E LOT 16 *SPRINKLERED* ROOF -SOFFIT SYSTEMS r.� ON GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 THRIVE HOME GENERIC 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- GoddenjSudik ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. www.goddensudik.com FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER Suite 250 BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S OE m DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER —_—_ F_ rLn WJ LU L ! O ZO wO U C) = W 0e Z (D JOINTS. WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS CONSTRUCTION APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. ISSUE DATE 7/21/2020 APPROPRIATE ROOF COVERING. CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR TRUSSES. APPROX. CEILING WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 TYPE - O ROOF VENTING NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL ROOF NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • VENTILATION REQUIRED: ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED WITH CORROSION -RESISTANT WIRE CLOTH SCREENING OR SIMILAR MATERIAL W/ OPENINGS HAVING A LEAST DIMENSION OF 1/16" MIN. AND 1/4" MAX. PER 2018 IRC SECTION R806.1. • MINIMUM VENT AREA: THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. REDUCTION OF THE MINIMUM NET FREE VENTILATING AREA TO 1/300 IS PERMITTED PROVIDED THAT AT LEAST 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS, PER 2018 IRC SECTION R806.2. • VENT AND INSULATION CLEARANCE: ROOF VENT LOCATIONS TO BE COORDINATED WITH TRUSSES SO AS NOT TO BLOCK THE FREE FLOW OF AIR AND REDUCE THE NET FREE AREA. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AT THE LOCATION OF THE VENT PER 2018 IRC SECTION R806.3. • INSULATION BAFFLES: WHERE SOFFIT VENTS ARE INDICATED, INSTALL INSULATION BAFFLES TO PROVIDE CLEAR AIR SPACE AS REQUIRED. REFER TO DETAILS FOR ADDITIONAL INFORMATION. • LIMIT ROOF VENTS TO NO MORE THAN TWO OPENINGS PER ROOF SHEATHING PANEL WITH NO TWO OPENINGS IN THE SAME PANEL BETWEEN THE SAME TRUSSES. • UNVENTED ATTIC AND UNVENTED ENCLOSED RAFTER ASSEMBLIES PERMITTED PER 2018 IRC SECTION R806.5. AREA INDICATES COMPLIANCE W/ IRC 2012 R302.2.2 EXCEPTION - IN LIEU OF PARAPET WALLS THE ROOF SHEATHING IS NOTED AS BEING FIRE RETARDANT TREATED WOOD FOR A MINIMUM OF 4 FEET FROM THE WHICHPROPERTY LINE FOR PENETRATIONSOF VENTS AND INTAKES ••••••••••••• LINE INDICATES SOFFIT VENTS APPROXIMATE AREA AVAILABLE FOR INSTALLATION OF SOLAR PANELS. LOCATION VARIES PER SITE ORIENTATION. CONTRACTOR TO COORDINATE DETAILS AND L REQUIREMENTS OF INSTALLATION, TYP. 4REA SEPARATION WALLS ROOF PLAN NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS. ALL SOFFITS ARE TO BE FLAT, U.N.O. • ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER THE SUPERVISION OF A COLORADO LICENSED STRUCTURAL ENGINEER. • ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES. PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO CONNECT ROOF AREAS. • PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO PROVIDE ATTIC VENTILATION AS REQUIRED PER 2018 IRC SECTION R806. RE: ROOF VENTING NOTES AND CALCULATIONS. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2018 IRC SECTION P2606. WHERE APPLICABLE, PENETRATIONS IN FIRE -RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH THE REQUIREMENTS OF THE IRC. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2018 IRC SECTION P2607. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. • ROOF ASSEMBLIES PER 2018 IRC CHAPTER R901: ROOF ASSEMBLIES SHALL PROVIDE A WEATHER RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER PROTECTION PER 2018 IRC SECTION R903 AND ROOF COVERINGS PER SECTION R905. RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION. • CRICKETS AND SADDLES SHALL BE INSTALLED AT THE REQUIRED LOCATIONS PER 2018 IRC SECTION R903.2.2. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE TO THE CRICKET OR SADDLE SLOPE. • LOW SLOPE ROOFS -ASPHALT SHINGLES: ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2018 IRC SECTION R905.2.2. • AN ICE BARRIER SHALL BE INSTALLED AT EAVES, EXTENDING FROM THE LOWEST EDGE TO A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2018 IRC SECTION R905.1.2 OR AS REQUIRED BY LOCAL AMENDMENTS. • ROOF DRAINAGE PER 2018 IRC SECTION R801.3: SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER BUILDER'S SPECIFICATION AND MANUFACTURER'S REQUIREMENTS BASED ON THE RAINFALL RATE AND CALCULATED AREA BEING DRAINED. WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. GA FILE NO. ASW GYPSUM WALLBOARD, STEEL H STUDS 2 HOUR FIRE 1004 60 TO 64 PROPRIETARY* STC SOUND TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) n 0 0 w 0 .Q 0 N1 thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 OE m �G \ac LU U O C) F_ rLn WJ LU L ! O ZO wO U C) = W 0e Z (D <w 3� 0 V O LTLJ i O oe -3: CONSTRUCTION SET ISSUE DATE 7/21/2020 3-PLEX-A ROOF PLAN A1.30 a v C�: a a M a EC P3 -E COMPOSITE WOOD LEFT ELEVATION LOT 18 DECK, TYP. 1/4" = 1'-0" 1X4 CORNER TRIM 10" COMPOSITE LAP SIDING (6 OVER 1X10 kSCIA 3PHALT SHINGLE JOFING JTTERS AND JWNSPOUTS, TYP. %I NT TO MATCH DJACENT MATERIALS (10 CORNER RIM BOARD COMPOSITE \P SIDING (4 TRIM DARD (8 TRIM BOARD ETAL AWNING. DWDER COATED -ACK DHERED MASONRY 04 M 1'-10" HEEL. 2'-0" O.H. BLOCK 3, LOTS 16-18 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE rh 3RD PLATE -- c 0 0L-LL00 ADHERED MASONRY oOFoO - o C �o �o o ❑IE 4" COMPOSITE - o �� ❑ o c LAP SIDING 1X10 CORNER ❑o ❑0 0o E I IE TRIM ❑o 0 oOo oOoo BOARD =0 =E:) - OoDOoDOL o� 000❑a o�❑a o� � �o 0o O000Ooo 3RD LEVEL ��❑00❑00❑ M VE o2ND PLATE �❑o❑�Oo C ooa000a000 TIE BACKS FOR DECK oO o VINYL WINDOWSoOC������O 00❑� oo E E 36" H. METAL o ooF o RAILING. 00 POWDER COATED = 00 =1=1: 1 BLACK oCOoO o o o moo❑❑o oo❑o0 00 E o a DOa DOa E 0 ooa000a000 METAL AWNI NG.00❑00❑I POWDER COATED - o��oOOo= C BLACK0�00L_jL-1 O� D❑❑oOS 1 1 H 0000❑❑oEOE oo �o ooa moa �oa�o oO O000Ooo � 2ND LEVEL M oOOoOOoL—i — ooOOoOOo C 1 ST PLATEao �o ooa moa �o_a�oc�ooa E==c F�= OoC❑L oO C _ �o°0 °°❑E E _ = oo Doo❑ moo❑ moo❑ oo a o❑ o0 oo ��o ��o moo E �o oO O000Ooo �0 00 0 E o��oOOoOOoOOoC❑�oO C o��DoO�DoO���o�o��Do 0 000❑❑o oo❑❑o oo❑�oo�oo❑ oo E 0 0000000��0 _ 00 o E 1ST LEVEL �nri nri 11 � �n��� c FRONT ELEVATION 1/4" = 1'-0" P3 -E LOT 18 1'-2" HEEL. 2'-0" O.H. I ii P1-1 LOT 17 *SPRINKLERED* PLOT PLAN NOTES BLOCK 3, LOTS 10-12 PLOT PLAN ISSUE DATE: 09/10/2020 (REVISION 1: 10/15/2020) LOT 10 • TOS = 24.4 • GARAGE SLAB = 23.6 LOT 11 • TOS = 25.1 • GARAGE SLAB = 23.8 LOT 12 • TOS = 25.1 • GARAGE SLAB = 24.0 POUR 4" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE M 1'-10" HEEL. 2'-0" O.H. A% 0 iii �� —]I �� � /// I � PRIVACY DOOR P2 -E LOT 16 ELEVATION NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON ELEVATIONS. • REFER TO BUILDING SECTIONS FOR ADDITIONAL WALL CONSTRUCTION, PLATE HEIGHTS, AND NOTES. • REFER TO PLANS AND DETAILS FOR FIRE RATED ASSEMBLY LOCATIONS, PER LOT SPECIFIC CONDITION. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2018 IRC SECTION P2606. WHERE APPLICABLE, PENETRATIONS IN FIRE -RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH THE REQUIREMENTS OF THE IRC. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2018 IRC SECTION P2607. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • EXTERIOR COVERING PER 2018 IRC SECTION R703: EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4. RE: DETAILS FOR ADDITIONAL INFORMATION. • HEIGHT ABOVE FINISHED GRADE (FOUNDATIONS): FOUNDATION WALLS SHALL EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS A MINIMUM OF 4" WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6" ELSEWHERE PER 2018 IRC SECTION R404. • CLEARANCE TO GRADE PER 2018 IRC SECTION R703: UNLESS NOTED OTHERWISE OR WHEN DIRECTED PER MANUFACTURER'S INSTALLATION REQUIREMENTS, EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE A MINIMUM OF 4" FOR BEARING AND ADHERED MASONRY VENEERS AND A MINIMUM OF 6" FOR OTHER WALL CLADDINGS. EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FLATWORK OR ROOF SURFACES A MINIMUM OF 2". • TYPICAL WINDOW HEAD HEIGHT, U.N.O. LOWER LEVEL: 8'-0" MAIN LEVEL: 8'-0" UPPER LEVEL: 8'-0" 1X6 OVER 1X10 FASCIA ASPHALT SHINGLE ROOFING GUTTERS AND DOWNSPOUTS, TYP. PAINT TO MATCH ADJACENT MATERIALS 4" TRIM AT DOORS AND WINDOWS TIE BACKS FOR DECK 6" COMPOSITE LAP SIDING 1X8 TRIM BOARD 8" EXPOSURE VERTICAL COMPOSITE PANEL SIDING DRAIN THROUGH, COMPOSITE WOOD DECK, TYP. LIGHT FIXTURE, RE: ELECTRICAL ADDRESS PLAQUE, TYP. FONT AS ART DECO OR SIMILAR P2 n 0 s2 0 0 .o, thriveHOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM 40 GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat o �Q; m �G \oc LU U O C) r� V V V ! LU O ZO wO U W 0e Z (D < 3� 0 V O w I O CONSTRUCTION SET ISSUE DATE 7/21/2020 3-PLEX-A BUILDING ELEVATIONS A3.01 7t M v �a 3RD PLATE rh 3RD LEVEL 2ND PLATE v 1X8 TRIM BOARD 36" H. METAL RAILING. POWDER COATED BLACK DRAIN THROUGH, COMPOSITE WOOD DECK, TYP. METAL AWNING. POWDER COATED BLACK 2ND LEVEL 1 ST PLATE 1X8 CORNER TRIM BOARD ADHERED MASONRY 1X4 TRIM BOARD SPACED EVENLY ALONG WALL 1ST LEVEL d P2 -E LOT 16 RIGHT ELEVATION *SPRINKLERED* 1/4" = 1'-0" SKU t-L/i I C 3RD LEVEL 2ND PLATE 6" Cc i 1X 2ND LEVEL 1ST PLATE i 1ST LEVEL )MPOSITE LAP SIDING 1X8 CORNER TRIM BOARD 8 TRIM BOARD 1X6 OVER 1X10 FASCIA ASPHALT SHINGLE ROOFING GUTTERS AND DOWNSPOUTS, TYP. PAINT TO MATCH ADJACENT MATERIALS EXTENDED WINDOW TRIM TO MEET CORNER TRIM. TYP @ END ELEVATIONS 4" TRIM AT DOORS AND WINDOWS 6" COMPOSITE LAP SIDING UTILITIES METERS RE: SITE PLAN 8" EXPOSURE VERTICAL COMPOSITE PANEL SIDING 04 M1 1'-10" HEEL. 2'-0" O.H. J I� BLOCK 3, LOTS 16-18 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat �G \ac Oo 0 W U 0 Q o r� V V V ! LU O Z O D U W 0e Z (D C) (D 0 w 0 ry CONSTRUCTION SET ISSUE DATE 7/21/2020 ❑O Oo po IF 0 o��O ❑ Oo opo 3-PLEX-A BUILDING ELEVATIONS A3.02 0 000O ❑O a o O o Oo ao ODo - - o - o_ 0 0 0 0 ❑a T 0 0 �: - -�-- - o 0 - Oo 0 Oho ❑O 0� O �o ooO Oo - OO_ D _ O a0OtAl OOO P2 -E LOT 16 RIGHT ELEVATION *SPRINKLERED* 1/4" = 1'-0" SKU t-L/i I C 3RD LEVEL 2ND PLATE 6" Cc i 1X 2ND LEVEL 1ST PLATE i 1ST LEVEL )MPOSITE LAP SIDING 1X8 CORNER TRIM BOARD 8 TRIM BOARD 1X6 OVER 1X10 FASCIA ASPHALT SHINGLE ROOFING GUTTERS AND DOWNSPOUTS, TYP. PAINT TO MATCH ADJACENT MATERIALS EXTENDED WINDOW TRIM TO MEET CORNER TRIM. TYP @ END ELEVATIONS 4" TRIM AT DOORS AND WINDOWS 6" COMPOSITE LAP SIDING UTILITIES METERS RE: SITE PLAN 8" EXPOSURE VERTICAL COMPOSITE PANEL SIDING 04 M1 1'-10" HEEL. 2'-0" O.H. J I� BLOCK 3, LOTS 16-18 BUILDING TYPE 3A LOT ADDRESS 16 7876 WEST 43RD PLACE 17 7880 WEST 43RD PLACE 18 7884 WEST 43RD PLACE V-2" HEEL. 2'-0" O.H. PLOT PLAN NOTES BLOCK 3, LOTS 10-12 PLOT PLAN ISSUE DATE: 09/10/2020 (REVISION 1: 10/15/2020) LOT 10 • TOS = 24.4 • GARAGE SLAB = 23.6 LOT 11 • TOS = 25.1 • GARAGE SLAB = 23.8 LOT 12 • TOS = 25.1 • GARAGE SLAB = 24.0 POUR 4" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE M1'-2" HEEL. 2'-0" O.H. 3' COMPOSITE LAP SIDING P2 -E P11 -1P3 -E LOT 16 1X8 TRIM BOARD LOT 17 JULIET BALCONY LOT 18 BETWEEN UNITS *SPRINKLERED* *SPRINKLERED* REAR ELEVATION 1/4" = 1'-0" ELEVATION NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON ELEVATIONS. • REFER TO BUILDING SECTIONS FOR ADDITIONAL WALL CONSTRUCTION, PLATE HEIGHTS, AND NOTES. • REFER TO PLANS AND DETAILS FOR FIRE RATED ASSEMBLY LOCATIONS, PER LOT SPECIFIC CONDITION. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2018 IRC SECTION P2606. WHERE APPLICABLE, PENETRATIONS IN FIRE -RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH THE REQUIREMENTS OF THE IRC. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2018 IRC SECTION P2607. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • EXTERIOR COVERING PER 2018 IRC SECTION R703: EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4. RE: DETAILS FOR ADDITIONAL INFORMATION. • HEIGHT ABOVE FINISHED GRADE (FOUNDATIONS): FOUNDATION WALLS SHALL EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS A MINIMUM OF 4" WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6" ELSEWHERE PER 2018 IRC SECTION R404. • CLEARANCE TO GRADE PER 2018 IRC SECTION R703: UNLESS NOTED OTHERWISE OR WHEN DIRECTED PER MANUFACTURER'S INSTALLATION REQUIREMENTS, EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE A MINIMUM OF 4" FOR BEARING AND ADHERED MASONRY VENEERS AND A MINIMUM OF 6" FOR OTHER WALL CLADDINGS. EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FLATWORK OR ROOF SURFACES A MINIMUM OF 2". • TYPICAL WINDOW HEAD HEIGHT, U.N.O. LOWER LEVEL: 8'-0" MAIN LEVEL: 8'-0" UPPER LEVEL: 8'-0" 1X6 OVER 1X10 FASCIA ASPHALT SHINGLE ROOFING GUTTERS AND DOWNSPOUTS, TYP. PAINT TO MATCH ADJACENT MATERIALS METAL AWNING. POWDER COATED BLACK COMPOSITE WOOD DECK, TYP. OVERHEAD GARAGE DOOR n 0 s0 0 0 0 thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat �G \ac W U 0 Q o r� V V V ! LU O Z O D U W 0e Z (D C) (D 0 w 0 ry CONSTRUCTION SET ISSUE DATE 7/21/2020 3-PLEX-A BUILDING ELEVATIONS A3.02 A.G. WASSENAAR, INC. TH Yarrow, LLC 1875 Lawrence Street, Suite 900 Denver, Colorado 80202 Attention: Subject: ,� NI h eat CD Mr. Jay Garcia Soil and Foundation Study Proposed Residential Structure Lots 16-18, Block 3 Yarrow Gardens, Filing 3 Wheat Ridge, Colorado Project Number 185530 March 25, 2020 Revised May 27,, 2020 Purpose As requested, A. G. Wassenaar, Inc. (AGW) performed a soil and foundation study at the subject site. The purpose of our study was to observe subsurface conditions encountered and to recommend geotechnical design criteria for the design and construction of the foundation for the proposed triplex residential structure. For purposes of this study, we understand and assume the overexcavation recommendations provided in our report, "Geotechnical Site Development Study for Proposed Townhome Development, Yarrow Gardens, Northwest of West 42nd Avenue and Yarrow Street, Wheat Ridge, Colorado", for the subject site,, AGW Project Number 181182,, dated May 11,, 2018,, have been followed. Density -compaction test reports (AGW Project Number 181182) were considered during the preparation of this study. The fill materials tested were placed in general accordance with the requirements of HUD Data Sheet 79G. This letter presents a summary of our findings and recommendations. Proposed Construction The proposed structure will be up to three stories supported upon a reinforced concrete foundation. It is our understanding no below grade areas are planned. The structure will be wood framed with a slab -on -grade or structural slab -on -void beneath the living areas. If plans change, the recommendations in this report must be reviewed by AGW prior to design and construction of the foundation. Subsurface Conditions The field exploration included drilling two 4 -inch diameter auger borings at the approximate diagonal corners of the anticipated building footprint. The subsurface conditions encountered are shown on Figures 1 and 2,, including the results of penetration tests at the locations of sampling. Laboratory Testing Samples obtained during drilling were returned to the laboratory. They were visually classified and testing was assigned to selected samples in an effort to evaluate the engineering properties of the subsurface materials encountered. The test results are summarized on Figures 1 and 2. Based upon 2180 South Ivanhoe Street,, Suite 5 • Denver, Colorado 80222 www.agwco.com 9 Phone 303-759-8100 visual observation of the subsurface conditions encountered and laboratory testing for this and/or adjacent lots, it is our opinion that the subsurface materials generally exhibit low potential for expansion and compression. Refer to the Colorado Geological Survey Special Publication 43 for a description of expansive soils and their impact on structure performance. Foundation Recommendations Based on our evaluation of the subsurface conditions, the proposed structure may be founded upon spread or pad -type footings bearing on the natural undisturbed soils or on properly placed and compacted fill. The footings should be designed for a maximum bearing pressure of 2,000 psf. Footing dimensions and foundation structural elements should be determined by a structural engineer. Concrete in contact with the subsurface materials may be designed for negligible (SO or o w he,31RSO) sulfate exposure as defined by either ACI 318 (Table 19.3.1.1) or ACI 332 (Table 5.2.1) as d4 mined from the appropriate building code for this jurisdiction. Bearing materials loosened by l/machine excavation should be removed prior to placing footing concrete. Occasionally, pockets of 6 dray, 'hard fill or very moist, soft fill may be encountered in the foundation excavation. If this condition 1'1a;,,q p:4\56ccurs, the footings should extend to properly moisture treated fill. Exterior footings should bear at least 3 feet below exterior grade for frost protection. The bearing materials beneath footings should be protected from freezing during construction. All footing excavations should be observed by AGW prior to placement of concrete. The foundation walls backfilled with on-site materials should be designed for a lateral earth pressure based upon an equivalent fluid density of 60 pounds per cubic foot (pcf) for the "at rest" condition or 45 pcf for the "active" condition. The "active" condition should only be used where wall movements of at least 0.5% of the wall height are allowed. These values have been provided without considerations for sloping backfill, surcharge loading or hydrostatic pressures. Construction of a drain system and proper surface drainage as discussed later in this report may lower the potential of developing hydrostatic pressure in the backfill materials. Minor cracking of concrete foundation walls should be expected. Concrete Slab Construction A concrete slab performance risk evaluation was conducted in general conformance with industry guidelines for the local area. The risk assessment of a site for potential movement is not absolute; rather, it represents a judgment based upon the data available and our experience in the area. Movement of foundations and concrete flat work will occur with time in low to very high risk areas as the soil moisture content increases. On low and moderate rated sites, slab movements of up to 3 inches across the slab with slab cracking of up to t/a-inch in width and/or differential are considered normal. The damage generally increases as the risk assessment increases and as the depth of wetting increases. It must be understood, however, that assessing risk is an opinion. There is currently no type of testing or correlation of factors that will definitively predict the amount of heave that a floor slab will exhibit. Therefore, it may be possible that heaves less than or in excess of what is considered "normal' may be experienced. For sites with a risk assessment of high or very high, we recommend an interior floor system engineered for expansive soils be constructed. In addition, a structurally supported floor AGW Project Number 185530 March 25, 2020; Revised May 27, 2020 TH Yarrow, LLC Page 2 system is recommended for all finished areas or any other areas where floor movements cannot be tolerated. Based upon our evaluation of the subsurface conditions at this site, it is our opinion that the slab performance risk for this site is low. If this risk of movement is not acceptable, structurally supported interior floors should be constructed. A slab -on -grade floor can be used provided the risk of movement and cracking is acceptable to the Client and the Homeowner. If the Homeowner cannot tolerate slab movement, they should request that a structurally supported floor be installed. If the Builder and/or Homeowner desires to construct a concrete slab -on -grade and accepts the risk of slab movement, slabs supported by the expansive subsurface materials should be constructed using the following criteria: o,Whear� 1. Slabs should be separated from exterior walls and interior bearing members with a USA %P joint which allows free vertical movement of the slab. 2. The use of slab bearing partitions should be minimized. Where necessary, slab bearing partitions should be constructed with a minimum 2 -inch void space. Doorways should 'lan9pxi\o also be designed to allow vertical movement of the slab. Drywall should not be in contact with the slab. Stairways bearing upon the slab should be constructed in such a way as to allow at least 2 inches of slab heave. In the event of slab heave, the movement should not be transmitted directly through the partitions to the remainder of the structure. The Homeowner should monitor the partition voids and other connections and re-establish the voids before they close to less than 1/2 -inch. 3. Plumbing and utilities should be isolated from the slab and be provided with flexible connections. The Homeowner must maintain these connections. 4. Where a forced air heating system is used and the furnace is located on the slab, we recommend provision for a collapsible connection between the furnace and the duct work to allow for at least 3 inches of slab heave. Utility connections should also be provided with flexible connections capable of accommodating the same magnitude of movement as specified above. 5. Frequent control joints should be provided in the slab to reduce problems associated with shrinkage cracking and curling. We recommend additional control joints be located approximately 3 feet away from and parallel to the foundation walls. Following these recommendations should reduce damage caused by movement of the floor slab. The void spaces recommended are not intended to predict total slab movement. Care should be taken to monitor and reestablish partition voids and flexible connections when necessary. We are available to provide further consultation regarding concrete slab performance risk assessments. If a slab -on -grade is finished, cosmetic damage should be expected (i.e., drywall cracks, sticking doors, floor tile cracking). Fill Placement Any fill placed beneath the foundation and slabs -on -grade should be well compacted. Prior to placement of fill, the ground surface should be scarified a minimum of 6 inches or pipes in trenches should be properly bedded. The new fill should be of similar soil type as the existing subgrade material. New fill should be placed in maximum 8 -inch loose lifts. The scarified ground surface and the new fill should be compacted to a minimum of 95% of Standard Proctor (ASTM D698) maximum AGW Project Number 185530 March 25, 2020; Revised May 27, 2020 TH Yarrow, LLC Page 3 dry density for cohesive soils or Modified Proctor (ASTM D1557) maximum dry density for granular soils. The moisture content of the compacted material should be between optimum and 4% over optimum moisture content for cohesive soils or within 2% of optimum moisture content for granular soils. Density compaction testing must be performed upon any new fill placed beneath the foundation of the structure. Backfill around the foundation should be moistened and compacted in such a manner as to reduce future settlement. Subsurface Drainage It is our understanding that no below grade areas are planned for the proposed three -unit townhome. Present ground water conditions, in our opinion, should not be a problem for the proposed structure. We believe if the ground surface and roof drainage are properly cared for, no subsurface drainage \� k W heatsystems should be necessary unless below grade areas are planned. /9rSurf;3ce Drainage 6 The wetting of foundation soils and/or bedrock materials may be reduced by carefully planned and �';a;,,q p:4\*aintainecl surface drainage. The following recommendations should be implemented during construction and maintained by the Homeowner or Homeowners Association after the structure is completed: 1. Excessive wetting or drying of the open foundation excavation should be avoided as much as practical during construction. 2. The ground surface surrounding the exterior of the foundation should be maintained in such a manner as to provide for positive surface drainage away from the foundation. At completion of construction, we recommend a minimum fall away from the foundation of 6 inches in the first 5 feet. This slope should be continuous across the backfill zone. 3. Areas which settle should be filled as soon as possible in order to maintain positive drainage away from the foundation. 4. If lawn edging is used around the exterior of the foundation, it should be constructed in a manner to prevent ponding of surface water in the vicinity of the backfill soils. 5. Drainage swales should be constructed and maintained a minimum of 5 feet away from the foundation on side yards and 15 feet away from the foundation on back and front yards. Natural drainage swales should maintain a slope of at least 2% off of the lot. Swales must not be blocked by fences, landscaping, paths or other Homeowner or Homeowners Association installed items. 6. Roof downspouts and drains should discharge well beyond the limits of foundation backfill. 7. Watering adjacent to the foundation should be reduced as much as practical. Landscaping which requires excessive watering should not be located within 5 feet of foundation walls. Sprinkler lines, zone control boxes, and drains should be located outside the limits of the foundation backfill. Sprinkler heads should be positioned such that the spray does not fall within 5 feet of foundation walls. 8. Plastic membranes should not be used to cover the ground surface immediately surrounding the foundation. These membranes tend to trap moisture and prevent normal evaporation from occurring. We recommend the use of a weed suppressant geotextile fabric. AGW Project Number 185530 March 25, 2020; Revised May 27, 2020 TH Yarrow, LLC Page 4 Limitations We believe the professional judgments expressed in this report are consistent with that degree of skill and care ordinarily exercised by practicing design professionals performing similar design services in the same locality, at the same time, at the same site and under the same or similar circumstances and conditions. No other warranty, express or implied, is made. The location of the test borings drilled and the laboratory testing performed for this study were designed to obtain a reasonably accurate picture of subsurface conditions for design purposes. Variations in subsurface conditions not indicated by the borings are possible and expected. Therefore, we should be retained to observe the foundation excavation and construction. If unexpected subsurface conditions are observed by others during construction, we should be called to review our recommendations. ok W hea1'�qis report was prepared for the exclusive use of our Client for the sole purpose of providing 96o4echnical design criteria for the subject structure based upon the existing site conditions as l/encountered. The conclusions and recommendations contained in this report shall not be considered 6 valid for use by Others without written authorization from AGW. In addition, the state of practice in °'1a;,,q pti\<§eotechnical engineering is constantly evolving. Therefore, findings presented in this report should be reviewed and revised, if necessary, prior to actual construction. The recommendations provided in this report are based upon the specified extents of the overexcavation for the original building footprint. The future Homeowner or Homeowners Association should not construct any additions to the structure utilizing the recommendations given in this report. Additional studies must be provided if any additions are to be constructed. If we can be of further service in discussing the contents of this letter or in analysis of proposed structure from the soil and foundation viewpoint, please call our office. Sincerely, Michael R. Conner, P� Senior Engineer Digitally sign by: Michael R Con Date: 2020.05.27 17:47:20 -07'00' Attachments: Figures 1 and 2 pp0 LICF� R. ., �O''•. Fp 30731 TE MRC/bab AGW Project Number 185530 TH Yarrow, LLC March 25, 2020; Revised May 27, 2020 Page 5 B3 L16 I'AGW A.G. WASSENAAR, INC. CLIENT TH Yarrow LLC. PROJECT NAME Yarrow Gardens, Filing 3 PROJECT NUMBER 185530-1 PROJECT LOCATION Wheat Ridge, Colorado DATE DRILLED February 24, 2020 GROUND WATER LEVELS: DRILLING METHOD 4 -inch Solid Stem Auger AT TIME OF DRILLING Dry NOTES Test boring drilled in the northwest corner 3 DAY(S) AFTER DRILLING 12 feet ATTERBERG a o w o O LIMITS U~ U `--'' �}J Qj q O MATERIAL DESCRIPTION o c 2 U ~ W w 0' ~ w 0 0� a QUA ooz �" z Ln o- a� �o z �i Ln�cn D O < a~ ' Oz U Fill, (moisture treated) sand and clay, medium dense to stiff, silty, moist, mottled brown ��ry�n DNS MC 32/ 12 8 5 a C7 z a MC 14/12 110 15 -1.3 10 0 Sandstone (bedrock), firm to medium hard, poorly cemented, silty, Cb clayey, moist to wet, brown to rust 0 Claystone (bedrock), medium hard, silty, sandy, moist to very MC 25/ 12 o 15 moist, gray to olive to rust Claystone (bedrock), hard, silty, slightly sandy, moist to very moist, o gray to olive to rust a m MC 50 / 11 Bottom of borehole at 19.9 feet. z W 0 a 0 a r a 0 N OJ Q V Z S V w F O w C7 N W LL W_ O a Figure 1 B3 L18 I'AGW A.G. WASSENAAR, INC. CLIENT TH Yarrow LLC. PROJECT NAME Yarrow Gardens, Filing 3 PROJECT NUMBER 185530-2 PROJECT LOCATION Wheat Ridge, Colorado DATE DRILLED May 15, 2019 GROUND WATER LEVELS: DRILLING METHOD 4 -inch Solid Stem Auger AT TIME OF DRILLING Dry NOTES Test boring drilled in the southeast corner 6 DAY(S) AFTER DRILLING 16.5 feet ATTERBERG a o w o OML LIMITS v 1�J q O MATERIAL DESCRIPTION LLI o 0 D� a w w o 0 0 w ov a Q�cn moz �" z moo" o� <. �o z 9 �2: n D O z _ Q� < D 0 a Fill, (moisture treated) sand and clay, medium dense to stiff, silty, moist, mottled brown MC 9/12 111 15 -0.4 5 a C7 z a MC 14/12 108 14 0.5 10 0 a r Sandstone (bedrock), firm to medium hard, poorly cemented, silty, Cb clayey, moist to wet, brown to rust 0 Claystone (bedrock), medium hard, silty, sandy, moist to very MC 33/ 12 o 15 moist, gray to olive to rust z 0 W a MC 35 / 12 20 O V Bottom of borehole at 20.0 feet. K Z w D K Q C7 O K K Q Q 0 N OJ Q V Z S V w F O w C7 N W LL W_ O a Figure 2 SITE SPECIFIC PLOT PLAN NOTES: LOT = 16 TOS = 24.4 GARAGE SLAB =23.6 LOT = 17 TOS = 25.1 GARAGE SLAB =23.8 LOT = 18 TOS = 25.1 GARAGE SLAB =24.0 POUR 4" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE REVISIONS: 10 21.20 - LABEL RAMPS AND ADA UNITS - AL. 18 x}016 10.29.20 - REDLINES PER DAVID KENDALL - AL. 04.27.21 - LOTS 16 AND 17 FRONT STOOPS MODIFIED PER NEW FOR. PLANS - AL. 05.05.21 - FRONT DOWNSPOUTS/PIPES MODIFIED PER DAVE - AL. 06.02.21 - ADDRESS CHANCE - AL. Reviewed for Zoning Compliance by the k4, City of Wheat Ridge Planning Division y�r� APPROVED BY: DATE: g/3/2021 COMMENTS: 0 20 40 SCALE: 1"=20' MODEL OPTIONS: SUBDIVISION: YARROW GARDENS FILING NO. 4 COUNTY: JEFFERSON CITY: WHEATRIDGE ADDRESS: I S L=7.17' R=19.0ON7V THB WestRidge LLC PLOT PLAN T ACT F PRIVATE ND EMF•RC- L 43RD T:,,,N\VARROW GARDENS P3\VARR0W GARDENS P3 tlwg 6AS0218:0312 AM, 8�N, LOT 16-18 BLOCK 3 LOT ADDRESS 16 7876 WEST 43RD CIRCLE 17 7880 WEST 43RD CIRCLE 18 7884 WEST 43RD CIRCLE • PLOT PLAN NOT TO BE USED FOR EXCAVATION PLAN OR FOUNDATION PLAN LAYOUT. • PLOT PLAN SUBJECT TO APPROVAL BY ZONINGEUILDING AUTHORITY PRIOR TO STAKEOUT. • EASEMENTS DISPLAYED ON THIS PLOT ARE FROM THE RECORDED PLAT AND MAY NOT INCLUDE ALL EASEMENTS OF RECORD. • PLOT PLAN MUST BE APPROVED BY BU ILDER PRIOR TO ORDERING TAKEOUT -20 LOT CORNER ELEVATION CHECK. 0926-19 oi` W heat. c) C) I �G9�0"0-91 X01 O LEGEND LOWERED FINISH GRADE: HOUSE xx.x PORCH ® GARAGE/CRAWL SPACE FX--Xl FOUNDATION STEP @x CONCRETE RISER COUNT CONCRETE ELEVATION [xx.x] GRADING PLAN ELEVATION CSAX.xx DICENTER OOF CURB STOP AT (exx.xx) DIRT/CONC. ELEVATION AT CENTER OF METER PIT urveying, Inc. vnmm.aea,s...bLn nss South Yosemite Street 1100 Centennial, CO 80112 : (303) 850-0559 Fax: (303) 850-0711 il: infoObisurvev.nef EASY 18 x}016 C) W dp 0,524 SOFT ED 809 SOF R = 1,094 SOFT U (� m 2 -CAR � a GARAGE 0�1 2 -CAR m W of Q ri n GARAGE 4-o #7880 4,6 GARAGE W d �z 8.0°.. o #7884 W l.. m W o #7876 0 m r�✓'aj M O� 54.24. 233 4..v M �r4'�11.9 lY Q 20.0 _ 20.0 w (2.4..031 2_ o o:K vARROWGARDE srp vARRowcnROE s ,2x vARRowcARDE s p1- Z LL F i U! s P2 -EF P3 -E 0) FOOTPRIII�94 0) o FOOTPRINT s R 001 W m 00 m ^ o FooTPRINT=Teo TOS=54 5.1 TOS=5424.4 "2 m `° d !nom TOS=5425.1 0 2.3' ^_ 0 0 ( rn 10 2. � 16. 20.0 3� L 20.0 srooP pro JDEC SLOOP M x p ^ 24. 23,7 I, 24_1 2 m.1°m'. �. 3.23x H Pin 1 24.1 23.66 23.8 u 1 %[3 423.92 V m a m • ty• _ r 3:2 2- {23. 69 �r-[ 81-23.8 a A�3 W44.1 4 11�L '21 77L 4' WALIZ 012,3 23 - �L 4230 V [24.61 ]N [23.91 .65 oowNsaouT 4" PVC ala TRAC ]C D 23.48 23.60 23.70 i h _ Reviewed bythe Cityof Wheat Ridge �•, Engineering Division NO EXCEPTIONS TAKEN By. Jordan Jefferies DATE: 611712021 COMMENTS: • PLOT PLAN NOT TO BE USED FOR EXCAVATION PLAN OR FOUNDATION PLAN LAYOUT. • PLOT PLAN SUBJECT TO APPROVAL BY ZONINGEUILDING AUTHORITY PRIOR TO STAKEOUT. • EASEMENTS DISPLAYED ON THIS PLOT ARE FROM THE RECORDED PLAT AND MAY NOT INCLUDE ALL EASEMENTS OF RECORD. • PLOT PLAN MUST BE APPROVED BY BU ILDER PRIOR TO ORDERING TAKEOUT -20 LOT CORNER ELEVATION CHECK. 0926-19 oi` W heat. c) C) I �G9�0"0-91 X01 O LEGEND LOWERED FINISH GRADE: HOUSE xx.x PORCH ® GARAGE/CRAWL SPACE FX--Xl FOUNDATION STEP @x CONCRETE RISER COUNT CONCRETE ELEVATION [xx.x] GRADING PLAN ELEVATION CSAX.xx DICENTER OOF CURB STOP AT (exx.xx) DIRT/CONC. ELEVATION AT CENTER OF METER PIT urveying, Inc. vnmm.aea,s...bLn nss South Yosemite Street 1100 Centennial, CO 80112 : (303) 850-0559 Fax: (303) 850-0711 il: infoObisurvev.nef GOVERNING CODE DATE: 2018 IRC SEISMIC CATEGORY= B 1 = 1.00 R=6.5 RISK = II ULT. WIND SPEED (3 -SECOND GUST) 115 MPH EXPOSURE C ROOF LOADS DEAD 20 PSF SNOW 30 PSF FLOOR LOADS DEFLECTION LL=L/360 TL=L/240 DEAD 12 PSF LIVE 40 PSF DECK LOADS DEAD 12 PSF LIVE 60 PSF MAX. SOIL BEARING PRESSURE 2000 PSF EQUIVALENT FLUID PRESSURE 45 PCF NOTE: THIS ENGINEERING DESIGN ASSUMES THE LOADS AND CRITERIA LISTED ABOVE. CONTRACTOR SHALL REVIEW THE LOADS & GEOTECHNICAL REPORT AND CONTACT YORK ENGINEERING PRIOR TO CONSTRUCTION IF ANY ADJUSTMENTS ARE REQUIRED. THE LOADS ABOVE ASSUME NO RADIANT HEAT FLOORING. FOUNDATION DESIGN IS IN ACCORDANCE WITH A.G. WASSENAAR, INC SUBSURFACE INVESTIGATION FOUNDATION RECOMMENDATIONS, PROJECT NUMBER 185529, DATED DECEMBER 6, 2018 REVISED MAY 27, 2020. DESIGN IS SUBJECT TO REVISION BASED ON RESULTS OF OPEN HOLE OBSERVATION. FOOTING, FOUNDATION AND CONCRETE 1. FOOTING DESIGN IS BASED ON ALLOWABLE SOIL BEARING PRESSURE AS PER GEOTECHNICAL REPORT, SEE PLAN. IF A PROJECT SOILS REPORT HAS BEEN COMPLETED, FOLLOW ALL REPORT RECOMMENDATIONS. FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR GRANULAR FILL COMPACTED TO 95% OF MAXIMUM DENSITY. NO FOOTINGS SHALL BE PLACED IN WATER OR ON FROZEN GROUND. ALL FOOTINGS TO BE PLACE AT MIN. BELOW LOCAL FROST DEPTH, AND BE CONTINUOUS AND MONOLITHIC POUR. 2. CHANGES IN ELEV. SHALL BE STEPPED WITH STEP HEIGHT NOT HIGHER THAN 1/2 THE STEP LENGTH AND NOT GREATER THAN 5'. NOTIFY ENGINEER IF GRADE DROPS OVER 8' IN 24' (GREATER THAN 1/3 SLOPE) SO THAT APPROPRIATE DESIGN CHANGES MAY BE MADE TO FOUNDATION AND FOOTINGS. 3. ALL FOOTINGS, FOUNDATIONS, AND INTERIOR SLABS SHALL BE NORMAL WT. CONCRETE WITH A COMPRESSIVE STRENGTH OF 2,500 PSI MIN. U.N.O. TO MEET STRENGTH REQUIREMENTS (SEE CALCS., NO SPECIAL INSPECTIONS REQUIRED U.N.O., SEE PLAN) HOWEVER, PER IRC 402.2 USE 3000 PSI CONCRETE FOR DURABILITY PURPOSES. THE WATER/CEMENT RATIO SHALL BE NO GREATER THAN .50 WITH A MINIMUM CEMENT CONTENT OF 504 LBS. PER CUBIC YARD. 4. ALL CONIC. WORK SHALL BE PLACED, CURED, STRIPPED, AND PROTECTED AS REQUIRED BY ACI STANDARDS AND PRACTICES. 5. ALL REINFORCING SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI STANDARD 318. REINFORCEMENT SHALL BE FREE FROM MUD AND OIL AND OTHER NON-METALLIC COATINGS THAT HAMPER BONDING CAPACITY. 6. OWNER\CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS LISTED ON THE DRAWING. VERIFICATION OF ALL SITE CONDITIONS INCLUDING SITE STABILITY IS THE RESPONSIBILITY OF OTHERS 7. ALLOW 14 DAYS FOR CONCRETE TO CURE PRIOR TO BACKFILL B. STRUCTURAL CONCRETE EXPOSED TO FREEZE THAW CYCLES SHALL HAVE 5% AIR ENTRAINMENT, MIN. 9. RUN FOOTINGS CONTINUOUS UNDER ALL DOOR OPENINGS, SEE PLAN. 10. SILL PLATE J -BOLTS SHALL BE A307 WITH 7" MIN. EMBEDMENT IN CONCRETE U.N.O., SEE PLAN. 11. TITEN HD BOLTS OR EPDXY THREADED RODS MAY BE USED AS SUBSTITUTION FOR SILL PLATE J -BOLTS AT SAME SIZE AND SPACING AS J -BOLTS. USE 6" TITEN HD OR WEDGE ANCHOR WITH MIN 1" EDGE DISTANCE FOR SINGLE SILL PLATE AND 8" BOLTS FOR DBL PLATE. 12. ALL FOUNDATION HOLDOWN STRAPS/ANCHORS SHALL BE ALIGNED WITH END OF SHEAR WALL ABOVE AND SHALL ATTACH TO FULL HEIGHT KING STUDS U.N.O., SEE PLAN. PROVIDE WOOD POST AT EACH HOLDOWN PER THE HOLDOWN SCHEDULE. DIMENSIONS TO HOLDOWN LOCATIONS MUST BE FIELD VERIFIED. 13. FOOTINGS TO BE CENTERED ON WALLS AND COLUMNS/POSTS U.N.O., SEE PLAN. 14. USE SIMPSON SET EPDXY FOR CONCRETE ANCHORS U.N.O., SEE PLAN. CONTINUOUS SPECIAL INSPECTIONS REQUIRED ON ALL EPDXY OPERATIONS UNLESS WAIVED BY ENGINEER AND THE BUILDING OFFICIAL 15. LAP REBAR 48 BAR DIAMETERS U.N.O., SEE PLAN. EXTEND HORIZONTAL BARS IN WALL MIN. 12" AROUND CORNERS. REINFORCING IN SLABS ON GRADE MAY BE LAPPED 24°. SPLICES IN BOTTOM STEEL IN CONCRETE BEAMS, FOUNDATION WALLS, AND CAST IN PLACE SUSPENDED SLABS SHALL BE STAGGERED 48 BAR DIAMETERS. IF SPLICES ARE NOT STAGGERED, SPLICE BARS 72 BAR DIAMETERS 16. LINTELS IN CONCRETE WALLS MAY BE AS FOLLOWS U.N.O., SEE PLAN; FOR S -O' MAX SPAN, 8" DEEP WITH (2) #4 BOTT. BARS, FOR 6'-0" MAX SPAN, 12° DEEP WITH (2) #4 BOTT. BARS. 17. PROVIDE (2) EDGE BARS ABOVE CONCRETE WALL OPENINGS AND (1) BAR EACH SIDE AND BELOW OPENINGS U.N.O., SEE PLAN. MATCH SIZE OF EDGE BARS WITH TYPICAL WALL REINFORCING AND PLACE WITHIN 4" OF OPENING EDGE. EXTEND BARS 48 BAR DIAMETERS PAST EDGE OF OPENING OR EXTEND AS FAR AS POSSIBLE AND PROVIDE 90' STANDARD HOOK AT END. 18. PROVIDE HORIZONTAL BAR WITHIN 3° OF TOP AND BOTT. OF WALL AND PROVIDE VERTICAL BAR AT ALL WALL CORNERS AND ENDS. YORK ENGINEERING INC. SPECIFICATIONS IS LIMITED TO THE STRUCTURAL DESIGN OF THE MAIN SUPPORTING ELEMENTS OF THIS STRUCTURE. NO OTHER DISCIPLINES OF THIS STRUCTURE INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, ELECTRICAL, PLUMBING, MECHANICAL WERE NOT REVIEWED FOR CODE COMPLIANCE OR COMPATIBILITY WITH THE DESIGN. THE PURPOSE OF THIS ENGINEERING IS TO HELP REDUCE STRUCTURAL DAMAGE AND LOSS OF LIFE DUE TO SEISMIC ACTIVITY AND/OR HIGH WIND CONDITIONS. NOTE: THIS ENGINEERING ASSUMES THAT THE CLEARANCE & SETBACK REQUIREMENTS LISTED IN IRC SECTION R403.1.7 ARE MET. IF THESE PROVISIONS ARE NOT MET, CONTACT THE ENGINEER FOR FURTHER DESIGN. NOTE: THIS ENGINEERING ASSUMES THAT THE SITE IS STABLE HAVING NO GLOBAL STABUTY CONCERNS OR HAZARDS. IF THIS IS NOT TRUE, CONTACT SOILS ENGINEER AND PROVIDE SOILS/SLOPE STABILITY REPORT TO YORK ENGINEERING FOR REVIEW AND FURTHER DESIGN. F NOTE: S131X30 BOLTS CI POST -INSTALLED. BOLTS CAST -IN-PLACE. DIMENSIONS SHOWN RE OF BOLT. REV1510N5 DATE: FOOTING SCHEDULE: DESCRIPTION: TYPE WIDTH LENGTH THICK REINFORCEMENT F-15 16" CONT. 8" NOT REQUIRED F-20 20" CONT. 8" (2) # 4 BARS CONT. NOTE: FOOTING REINFORCEMENT IN THIS SCHEDULE AND NOTED ON PLANS IS BOTTOM REINFORCING U.N.O. AND SHALL BE PLACED IN BOTTOM 1/2 OF FOOTING THICKNESS, WITH 3" CONCRETE CLEAR COVER, MIN. YORK ENGINEERING INC. SPECIFICATIONS IS LIMITED TO THE STRUCTURAL DESIGN OF THE MAIN SUPPORTING ELEMENTS OF THIS STRUCTURE. NO OTHER DISCIPLINES OF THIS STRUCTURE INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, ELECTRICAL, PLUMBING, MECHANICAL WERE NOT REVIEWED FOR CODE COMPLIANCE OR COMPATIBILITY WITH THE DESIGN. THE PURPOSE OF THIS ENGINEERING IS TO HELP REDUCE STRUCTURAL DAMAGE AND LOSS OF LIFE DUE TO SEISMIC ACTIVITY AND/OR HIGH WIND CONDITIONS. NOTE: THIS ENGINEERING ASSUMES THAT THE CLEARANCE & SETBACK REQUIREMENTS LISTED IN IRC SECTION R403.1.7 ARE MET. IF THESE PROVISIONS ARE NOT MET, CONTACT THE ENGINEER FOR FURTHER DESIGN. NOTE: THIS ENGINEERING ASSUMES THAT THE SITE IS STABLE HAVING NO GLOBAL STABUTY CONCERNS OR HAZARDS. IF THIS IS NOT TRUE, CONTACT SOILS ENGINEER AND PROVIDE SOILS/SLOPE STABILITY REPORT TO YORK ENGINEERING FOR REVIEW AND FURTHER DESIGN. F NOTE: S131X30 BOLTS CI POST -INSTALLED. BOLTS CAST -IN-PLACE. DIMENSIONS SHOWN RE OF BOLT. REV1510N5 DATE: # DESCRIPTION: BY: 4/28/2021 01 ADDED GRADE BEAM FOR POWDER BATH HD 5'-24„ O - F31_ , O NOTE: ALL CONTINUOUS FOOTINGS ARE 16" WIDE X 8" DEEP (F-16) UNLESS NOTED OTHERWISE 16,_4„ P-42 11„ W -10a" 6,_4„ 1' 42 11•, l,�la„ 16,_4„ 1'-101, (o�ya• (o� (O -*- °VO• ° � yO• S 'b 3b ND p�pJ� 13�� apo`' ND '�o �� ti��� ND u �Q1A o � yoGs cp�� 7 NOTE %"0 ALL -THREAD DRILLED & EPDXIED 8" INTO FOUNDATION ND ND ND ° ND - 0-*, 1 �9 e N � N ti3�9 NON-STRUCTURAL SLAB ON GRADE J. �ry°9 NON-STRUCTURAL SLAB ON GRADE I` NON-STRUCTURAL SLAB ON GRADE cq 0 -*- O ND 9 STEP I T.O.W. 8" 5'-24„ O - F31_ , STEP T.O.W. 8" 4'-92 3,_0„ L 7 17 Y� F . �99q#�° ND OO�IIN (�OeT a ° CBi�• N N -STRUCTURAL SLAB ON GRADE Q N a 9 ° it 0:' -STRUCTURAL SLAB ON GRADE e0 •<y LL ry 9� L Eq Q .11 16"X8" GRADE ^m BEAM W/ (2) #4 BARS CONTINUOUS �0 TBE ^o, O 11 1T BE a 4, 44 ND— CENTER Ll CONCRETE gyp' O.W. HAUNCH (TYP)u O.W. 2„ O STEP 3,-6" X94 ° 16,-o-„ NOTE: ALL CONTI OU 49.0 FOOTINGS ARE 16" WI X 8" 36'-02-'" DEEP (F-16) UNLESS NOTED OTHERWISE P2 -E LOT 15 7867 WEST 43RD 16"X8" GRADE BEAM W/ (2) #4 BARS CONTINUOUS 0.*. 4.0. 11 ND ••�• ti3g°j ND L -Z 12" T.O.W. 1„ 16'4" NOTE: %"4 ALL -THREAD DRILLED & �B O EPDXIED 8" INTO FOUNDATION 56'-6" P1 -I LOT 14 7863 WEST 43RD io 6n co 16"X8" GRADE 0 BEAM W/ (2) #4 BARS CONTINUOUS 11" NON-STRUCTURAL SLAB ON GRADE IND > \\\1 9. 442ND 10,-18, O 'O NOTE: SBiX30 BOLTS CANNOT BE POST -INSTALLED. BOLTS MUST BE CAST -IN-PLACE. DIMENSIONS SHOWN ARE TO CENTER OF BOLT. z0' -5a" P3 -E LOT 13 7855 WEST 43RD FOOTING/FOUNDATION PLAN SCALE: 1/4" =1'-0" 00* STEP .O.W.12" STEP .0.W.12' ro _T 0 o) m O •- ��rtFN o'•�F r Ir a r� a r r r , r 1'-%,04/28/2021 U] O O LLJ c) 0 LLJ Elf 0 Q u o Ul �J -i y) J O Q m W O Lo �;: LLT U) I- CD (n (Uo 00 00 0 0 Z I-- < LLJ O ro w J 00 = Q Ln Ln U GO r - \N heat 0 co F I City of COMMER CIA LIMUL TI- FA MIL Y �7�ThDEeatVELOPMENT dge BUILDING PERMIT APPLICATION REVIEW COMMUNITY Date: 5/14/2021 Location: 7876 W 43rd Cir ATTENTION: BUILDING DEPARTMENT I have reviewed the submitted application documents to construct a Townhome located at the above referenced address. Please note the comments checked below. 1. ✓ Site Survey: ✓ OK Not OK; refer to stipulations. 2. ✓ Drainage: a. Final Drainage Report and Plan required ✓ Yes No b. Drainage Letter and Plan required ✓ Yes No C. Site drainage/grading have been reviewed and are: ✓ OK Not OK; see stipulations 3. ✓ CDPS Permit & SWNIP Approved: ✓ Yes No _ N/A 4. ✓ Public Improvements to be comnleted: a. street paving/patching: ✓ Yes No b. curb & gutter/drivecut ✓ Yes No C. sidewalk: ✓ Yes No d. standard street lights: ✓ Yes _ No e. pedestrian lights: ✓ Yes _ No f. storm sewer: ✓ Yes No g. Letter of Credit (LOC) required: ✓ Yes No h. Funds in lieu of construction: TT Yes ✓ No If an LOC or funds in lieu of are required, has it been received? V/Yes No 5. ✓ SIA/PIA required and received 6. ✓ Traffic impact analysis required & approved: ✓ Yes No ✓ Yes No 7. ✓ If yes, was it approved by the Director of Public Works? ✓ Yes No 8. ✓ Does all existing roadway/alley R.O.W. meet the standards of the City: ✓ Yes No If not, what is required: N/A If R.O.W. is required, has the deed been received? ✓ Yes No (See Note below) NOTE: All deeds must be reviewed and approved prior to issuance of the Certificate of Occupancy. 9. ✓ APPROVED: The Public Works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated or attached stipulations. L� 5/14/2021 Signature Date 10._a Stipulations: A Grading Certification accompanied by an ILC or updated CCP w/ spot elevations shall be required prior to issuance of the final C.O. for the building. 11. ✓ NOTE: Any damage to the existing Public Improvements resulting from this construction shall be repaired to City standards prior to the issuance of the Certificate of Occupancy (C.O.). A Drainage/Grading Certification Letter with by As -Built plans or updated CCP shall be required prior to the issuance of the Certificate of Occupancy. Rev 04/2020 V 1( City of Wheat,p COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 ENGINEERING DEVELOPMENT REVIEW FEES Date: 5/14/2021 Location of Construction: 7876 W 43rd Cir Purpose of Construction: Single Family El Townhome Commercial El Multi -Family _a Sitework El Development Review Processing Fee: ................................................ $100.00 (Required of all projects for document processing) Single Family Residence/Duplex Review Fee: ..................................... $50.00 Commercial/Multii-Family Review Fees: (Fees include reviews of the l't and 2nd submittals) • Review of existing or minimal technical documents: ........................ $200.00 • Initial review' of technical civil engineering documents: ................ $600.00 • Traffic Impact Study Review Fee :.................................................... $600.00 • Trip Generation Study Review Fee :................................................... $200.00 • Stormwater Management Plan (SWMP) Review Fee :....................... $200.00 • O & M Schedule Review & SMA Recording Fee ............................. $100.00 • Construction Control Plan.................................................................. $100.00 $ 100.00 'Each Application will be reviewed by staff once and returned for changes. If after review of the second submittal changes requested by staff have not been fully made to the civil/slormwater/traffic documents, further reviews will be subject to the following Resubmittal Fees: • Resubmittal Fees: 3`d submittal ('h initial review fee): .................................................... $300.00 $ 4' submittal (full initial review fee): ................................................. $600.00 $ All subsequent submittals:................................................................. $600.00 X = $ (Full initial review fee) TOTAL REVIEW FEES (due at time of Building Pennit issuance): $100.00 PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE LICENSING AND PERMITTING FEES REQUIRED TO CONSTRUCT IMPROVEMENTS AND UTILITIES WITHIN THE PUBLIC RIGHT-OF-WAY. www.ci.wheatridge.co.us Rev 04/20 V 1( City of Wheat,p COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATE: 5/14/2021 ADDRESS: 7876 W 43rd Cir Dear Contractor: In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as determined by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the existing condition(s) of the public improvements at this address. If you have any questions, please contact me at 720-429-6051 Sincerely, Signature CC: File w .ci.wheatridgexo.us Rev 0420 From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: New Single -Family TOWNHOME UNIT Date: Monday, May 10, 20218:35:55 PM New Single -Family TOWNHOME UNIT THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Has the Master Plan Yes been approved for this project? Name of Project 3 Plex Lots 16-18. Blk 3 7876 7880 7884 W 43rd Cir PROPERTY INFORMATION Property Address - 7876 W 43rd Cir Only enter one unit on this application Property Owner Name THB Westridge LLC Property Owner Phone 303-766-7772 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email dvonfeldt@thrivehomebuilders.com Address PLAN REVIEW CONTACT INFORMATION What Is your role? General Contractor Business Name THB Westridge LLC Main Contact Name for Deia Vonfeldt Plan Review Contact Phone Number 303-766-7772 (enter WITH dashes, eg 303-123-4567) Contact Email Address dvonfeldt@thrivehomebuilders.com for Questions/Comments Retype Contact Email dvonfeldt@thrivehomebuilders.com Address DESCRIPTION OF WORK Detailed Scope of New SF TH-P2E- 2 car aft garage -1757 sq ft 460 sq ft garage Work - Example: New single family townhome with 2 car garage - 1,525 sq ft total (Bldg 1, B -unit) Square Footage of 1757 New Construction Foundation Plans for 7876 W 43rd Cir.Foundation Plan - STAMPED.pdf Specific Building Elevations of Building Site Specific. 7876 w 43RD Cir. Arch BLK 3 LOTS 16 Site Plan showing Unit Highlighted Floor plan of Unit Construction Plans Soil Report. F3 B3 L16-18.pdf scanned on 11'x17" or larger ( 191250 Pz_E Project Value contract Living Space 1391 $,zz.as value or cost of ALL Garage 720 $48.30 materials and labor) per&•deck, patio 31 $17.58 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. $170,341.88 $34,778.00 $544.38 $205,882.22 I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Deia Vonfeldt Permit Email not displaying correctly? View it in your browser. Lower Level 2- LDO-MORE SPACE 10'6'X lz•o• Revised 08.172020 Thrive Home Builders is a registered trademark of NT Builders, LLC. Thrive Home Builders rere the right to make changes i, price, color, mate..1s features, GM•NDWINNER specifications, models, options and availability at any time without mice. Floor plans and elevations are conceptual and should not be relied upon as a precire representation of a completed hm.. Floor plans, elevations, dimensions, square EPA Indoor f„sages and related iform.tm, are appr,bmate and subject t mange wh„t pr- aI rPLU.tS ZERO notice. Field co,ditionsi,cludi,g dimensions and square foot.g. will vary. Drawings �4rim Ate' Shown are not to scale. 02020 NT Builders, LLC. No reproductions or other ure of ••�•^�•�•�^ there plans may be made without express w.tte, consent of NT Builders, LLC. 7876 W 43rd Circle P2E Main Level PWDR DINING I 6 13'0"X11'0' oN � LIVING 15r0"X12'4" AIL DECK 19'6" X 3'0” ES KITCHEN 15'0" X I Too Upper Level BATH 2 BEDROOM 2 10'6'%10'6' iii MECH T DN LAUNDRY MASTER BATH MASTER BEDROOM 14!4"X 11'6" MASTER CLOSET Only production builder WestRidge Laurie Smith t Streez in the U.S. to win this 4249 Yarrow Community Sales ManagerInnovation in Housing Award Wheat Ridge, CO 80033 LSmith@ThriveHomeBuilders,com 7 years in a row! Thrive HomeBuilders,com 303.707.4448 Homes that do more. From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: New Single -Family TOWNHOME UNIT Date: Monday, May 3, 2021 11:40:17 PM New Single -Family TOWNHOME UNIT THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Has the Master Plan Yes been approved for this project? Name of Project 3 Plex 13-15 Blk 3 7855 7863 7867 W 43rd PI PROPERTY INFORMATION Property Address - 7867 W 43rd PI Only enter one unit on this application Property Owner Name THB Westridge LLC Property Owner Phone 3037667772 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email dvonfeldt@thrivehomebuilders.com Address PLAN REVIEW CONTACT INFORMATION What Is your role? General Contractor Business Name THB Westridge LLC Main Contact Name for Deia J Vonfeldt Plan Review Contact Phone Number 3037667772 (enter WITH dashes, eg 303-123-4567) Contact Email Address dvonfeldt@thrivehomebuilders.com for Questions/Comments Retype Contact Email dvonfeldt@thrivehomebuilders.com Address DESCRIPTION OF WORK Detailed Scope of New SF IRC TH -w 2 car garage -End Unit, Accessible,P2E 1497 Work - Example: New sq ft total 460 sf garage, A/C, Fire Sprinkler single family townhome with 2 car garage - 1,525 sq ft total (Bldg 1, B -unit) Square Footage of New Construction 1757 Foundation Plans for 7867 W 43rd PI Foundation Plan - STAMPED.odf Specific Building Elevations of Building 7867 W 43rd DI Arch -Site Specific. 15�Ddf 13-15.BLK 3 LOTS 13- Site Plan showing Unit 7867 W 43rd PI B3J 13-15 Plot Plan Ddf Highlighted Floor plan of Unit 7867 W 43rd PI P2 Floor Plan Ddf Construction Plans Soil Report F3 33 L13-15.pdf scanned on 11'x17" or larger Project Value (contract P2 -E $213,000 Living Space 1391 $122.46 $170,341.68 value or cost of ALL Garage 720 $46.30 $34,776.00 materials and labor) pot&, deck, patio 31 $17.56 $544.36 $205,662.22 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Deia Vonfeldt Permit Email not displaying correctly? View it in your browser. City of COMMER CIA LIMUL TI- FA MIL Y �7�ThDEeatVELOPMENT dge BUILDING PERMIT APPLICATION REVIEW COMMUNITY Date: 5/14/2021 Location: 7867 W 43rd PI ATTENTION: BUILDING DEPARTMENT I have reviewed the submitted application documents to construct a Townhome located at the above referenced address. Please note the comments checked below. 1. ✓ Site Survey: ✓ OK Not OK; refer to stipulations. 2. ✓ Drainage: a. Final Drainage Report and Plan required ✓ Yes No b. Drainage Letter and Plan required ✓ Yes No C. Site drainage/grading have been reviewed and are: ✓ OK Not OK; see stipulations 3. ✓ CDPS Permit & SWNIP Approved: ✓ Yes No _ N/A 4. ✓ Public Improvements to be comnleted: a. street paving/patching: ✓ Yes No b. curb & gutter/drivecut ✓ Yes No C. sidewalk: ✓ Yes No d. standard street lights: ✓ Yes _ No e. pedestrian lights: ✓ Yes _ No f. storm sewer: ✓ Yes No g. Letter of Credit (LOC) required: ✓ Yes No h. Funds in lieu of construction: TT Yes ✓ No If an LOC or funds in lieu of are required, has it been received? V/Yes No 5. ✓ SIA/PIA required and received 6. ✓ Traffic impact analysis required & approved: ✓ Yes No ✓ Yes No 7. ✓ If yes, was it approved by the Director of Public Works? ✓ Yes No 8. ✓ Does all existing roadway/alley R.O.W. meet the standards of the City: ✓ Yes No If not, what is required: N/A If R.O.W. is required, has the deed been received? ✓ Yes No (See Note below) NOTE: All deeds must be reviewed and approved prior to issuance of the Certificate of Occupancy. 9. ✓ APPROVED: The Public Works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated or attached stipulations. L� 5/14/2021 Signature Date 10._a Stipulations: A Grading Certification accompanied by an ILC or updated CCP w/ spot elevations shall be required prior to issuance of the final C.O. for the building. 11. ✓ NOTE: Any damage to the existing Public Improvements resulting from this construction shall be repaired to City standards prior to the issuance of the Certificate of Occupancy (C.O.). A Drainage/Grading Certification Letter with by As -Built plans or updated CCP shall be required prior to the issuance of the Certificate of Occupancy. Rev 04/2020 V 1( City of Wheat,p COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 ENGINEERING DEVELOPMENT REVIEW FEES Date: 5/14/2021 Location of Construction: 7867 W 43rd PI Purpose of Construction: Single Family El Townhome Commercial El Multi -Family _a Sitework El Development Review Processing Fee: ................................................ $100.00 (Required of all projects for document processing) Single Family Residence/Duplex Review Fee: ..................................... $50.00 Commercial/Multii-Family Review Fees: (Fees include reviews of the l't and 2nd submittals) • Review of existing or minimal technical documents: ........................ $200.00 • Initial review' of technical civil engineering documents: ................ $600.00 • Traffic Impact Study Review Fee :.................................................... $600.00 • Trip Generation Study Review Fee :................................................... $200.00 • Stormwater Management Plan (SWMP) Review Fee :....................... $200.00 • O & M Schedule Review & SMA Recording Fee ............................. $100.00 • Construction Control Plan.................................................................. $100.00 $ 100.00 'Each Application will be reviewed by staff once and returned for changes. If after review of the second submittal changes requested by staff have not been fully made to the civil/slormwater/traffic documents, further reviews will be subject to the following Resubmittal Fees: • Resubmittal Fees: 3`d submittal ('h initial review fee): .................................................... $300.00 $ 4' submittal (full initial review fee): ................................................. $600.00 $ All subsequent submittals:................................................................. $600.00 X = $ (Full initial review fee) TOTAL REVIEW FEES (due at time of Building Pennit issuance): $100.00 PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE LICENSING AND PERMITTING FEES REQUIRED TO CONSTRUCT IMPROVEMENTS AND UTILITIES WITHIN THE PUBLIC RIGHT-OF-WAY. www.ci.wheatridge.co.us Rev 04/20 V 1( City of Wheat,p COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATE: 5/14/2021 ADDRESS: 7867 W 43rd PI Dear Contractor: In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as determined by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the existing condition(s) of the public improvements at this address. If you have any questions, please contact me at 720-429-6051 Sincerely, Signature CC: File w .ci.wheatridgexo.us Rev 0420 Cit®f opt Wh6,atid e COMMUNITY DEVELOPMENT g SUB -CONTRACTOR AUTHORIZATION FORM This form must be siMed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be up to date prior to permit issuance. 7855,7863, 7867 W 43rd Pl Project Address: Permit #:_ General Contractor: THB WeWdge LLC Electrical Snub -Contractor ` Company Name. Phone #• State License #: Master # 2 13-0 Wh6t Ridue 7lcense.#c.. (required field) lure Of * "6w orized Agent Da IPlumbing Sub -Contractor Company Name: C&T Plumbing Phone #: 303-978-1051 State License #:_O o o ? Z 9� Master #: O D � S wheat Ridge.Ucense #: Q C.; o . (required field) Signature of orized Agent Date I Mechanical Contractor I Company Name: "ee, l T Phone; 31)&7& r -/ a747 t� : (required field) ture of Authorized Agent Date City of j Wheat COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address• 7863 7867 7866 w 43rd Place General Contractor: TAP, P, W P S-Ff Ay LLC FORM WILL NOT BE ACCEPTED WITH MISSING INFORMATION Company Name: -r,-\G Contact Phone #: 1ys,� Wheat Ridge Contractor License #: I SODS 9 Jrequired field) State License #: Master License #: Loy 3 lAC� 0QGtzCkkeS Printed NAme of Authorized Agent �(1-Ilkrl�x� �f aU �O Sig re dfAuthorized Agent Date City of W heat idge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must 19'x' -completed & signed by the ELECTRICAL SUBCONTRACTOR f''- performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address. - 7855, 7863, 7867 W 43rd PI General Contractor: THB Westridge LLC TED Company Name: Wheat Ridge Contractor License #: 0 State License #:E(.. 060710 Master License #: AAL QQaiiv l0, �n ? -dOL II Printec Name of Authorized Agent l� ?a Signatur of Authorized Agent Contact Phone #: 303-430-141`i (required field) Sr- 7 -Pzv Date GOVERNING CODE DATE: 2018 IRC SEISMIC CATEGORY= B 1 = 1.00 R=6.5 RISK = II ULT. WIND SPEED (3 -SECOND GUST) 115 MPH EXPOSURE C ROOF LOADS DEAD 20 PSF SNOW 30 PSF FLOOR LOADS DEFLECTION LL=L/360 TL=L/240 DEAD 12 PSF LIVE 40 PSF DECK LOADS DEAD 12 PSF LIVE 60 PSF MAX. SOIL BEARING PRESSURE 2000 PSF EQUIVALENT FLUID PRESSURE 45 PCF NOTE: THIS ENGINEERING DESIGN ASSUMES THE LOADS AND CRITERIA LISTED ABOVE. CONTRACTOR SHALL REVIEW THE LOADS & GEOTECHNICAL REPORT AND CONTACT YORK ENGINEERING PRIOR TO CONSTRUCTION IF ANY ADJUSTMENTS ARE REQUIRED. THE LOADS ABOVE ASSUME NO RADIANT HEAT FLOORING. FOUNDATION DESIGN IS IN ACCORDANCE WITH A.G. WASSENAAR, INC SUBSURFACE INVESTIGATION FOUNDATION RECOMMENDATIONS, PROJECT NUMBER 185529, DATED DECEMBER 6, 2018 REVISED MAY 27, 2020. DESIGN IS SUBJECT TO REVISION BASED ON RESULTS OF OPEN HOLE OBSERVATION. FOOTING, FOUNDATION AND CONCRETE 1. FOOTING DESIGN IS BASED ON ALLOWABLE SOIL BEARING PRESSURE AS PER GEOTECHNICAL REPORT, SEE PLAN. IF A PROJECT SOILS REPORT HAS BEEN COMPLETED, FOLLOW ALL REPORT RECOMMENDATIONS. FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR GRANULAR FILL COMPACTED TO 95% OF MAXIMUM DENSITY. NO FOOTINGS SHALL BE PLACED IN WATER OR ON FROZEN GROUND. ALL FOOTINGS TO BE PLACE AT MIN. BELOW LOCAL FROST DEPTH, AND BE CONTINUOUS AND MONOLITHIC POUR. 2. CHANGES IN ELEV. SHALL BE STEPPED WITH STEP HEIGHT NOT HIGHER THAN 1/2 THE STEP LENGTH AND NOT GREATER THAN 5'. NOTIFY ENGINEER IF GRADE DROPS OVER 8' IN 24' (GREATER THAN 1/3 SLOPE) SO THAT APPROPRIATE DESIGN CHANGES MAY BE MADE TO FOUNDATION AND FOOTINGS. 3. ALL FOOTINGS, FOUNDATIONS, AND INTERIOR SLABS SHALL BE NORMAL WT. CONCRETE WITH A COMPRESSIVE STRENGTH OF 2,500 PSI MIN. U.N.O. TO MEET STRENGTH REQUIREMENTS (SEE CALCS., NO SPECIAL INSPECTIONS REQUIRED U.N.O., SEE PLAN) HOWEVER, PER IRC 402.2 USE 3000 PSI CONCRETE FOR DURABILITY PURPOSES. THE WATER/CEMENT RATIO SHALL BE NO GREATER THAN .50 WITH A MINIMUM CEMENT CONTENT OF 504 LBS. PER CUBIC YARD. 4. ALL CONIC. WORK SHALL BE PLACED, CURED, STRIPPED, AND PROTECTED AS REQUIRED BY ACI STANDARDS AND PRACTICES. 5. ALL REINFORCING SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI STANDARD 318. REINFORCEMENT SHALL BE FREE FROM MUD AND OIL AND OTHER NON-METALLIC COATINGS THAT HAMPER BONDING CAPACITY. 6. OWNER\CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS LISTED ON THE DRAWING. VERIFICATION OF ALL SITE CONDITIONS INCLUDING SITE STABILITY IS THE RESPONSIBILITY OF OTHERS 7. ALLOW 14 DAYS FOR CONCRETE TO CURE PRIOR TO BACKFILL B. STRUCTURAL CONCRETE EXPOSED TO FREEZE THAW CYCLES SHALL HAVE 5% AIR ENTRAINMENT, MIN. 9. RUN FOOTINGS CONTINUOUS UNDER ALL DOOR OPENINGS, SEE PLAN. 10. SILL PLATE J -BOLTS SHALL BE A307 WITH 7" MIN. EMBEDMENT IN CONCRETE U.N.O., SEE PLAN. 11. TITEN HD BOLTS OR EPDXY THREADED RODS MAY BE USED AS SUBSTITUTION FOR SILL PLATE J -BOLTS AT SAME SIZE AND SPACING AS J -BOLTS. USE 6" TITEN HD OR WEDGE ANCHOR WITH MIN 1" EDGE DISTANCE FOR SINGLE SILL PLATE AND 8" BOLTS FOR DBL PLATE. 12. ALL FOUNDATION HOLDOWN STRAPS/ANCHORS SHALL BE ALIGNED WITH END OF SHEAR WALL ABOVE AND SHALL ATTACH TO FULL HEIGHT KING STUDS U.N.O., SEE PLAN. PROVIDE WOOD POST AT EACH HOLDOWN PER THE HOLDOWN SCHEDULE. DIMENSIONS TO HOLDOWN LOCATIONS MUST BE FIELD VERIFIED. 13. FOOTINGS TO BE CENTERED ON WALLS AND COLUMNS/POSTS U.N.O., SEE PLAN. 14. USE SIMPSON SET EPDXY FOR CONCRETE ANCHORS U.N.O., SEE PLAN. CONTINUOUS SPECIAL INSPECTIONS REQUIRED ON ALL EPDXY OPERATIONS UNLESS WAIVED BY ENGINEER AND THE BUILDING OFFICIAL 15. LAP REBAR 48 BAR DIAMETERS U.N.O., SEE PLAN. EXTEND HORIZONTAL BARS IN WALL MIN. 12" AROUND CORNERS. REINFORCING IN SLABS ON GRADE MAY BE LAPPED 24°. SPLICES IN BOTTOM STEEL IN CONCRETE BEAMS, FOUNDATION WALLS, AND CAST IN PLACE SUSPENDED SLABS SHALL BE STAGGERED 48 BAR DIAMETERS. IF SPLICES ARE NOT STAGGERED, SPLICE BARS 72 BAR DIAMETERS 16. LINTELS IN CONCRETE WALLS MAY BE AS FOLLOWS U.N.O., SEE PLAN; FOR S -O' MAX SPAN, 8" DEEP WITH (2) #4 BOTT. BARS, FOR 6'-0" MAX SPAN, 12° DEEP WITH (2) #4 BOTT. BARS. 17. PROVIDE (2) EDGE BARS ABOVE CONCRETE WALL OPENINGS AND (1) BAR EACH SIDE AND BELOW OPENINGS U.N.O., SEE PLAN. MATCH SIZE OF EDGE BARS WITH TYPICAL WALL REINFORCING AND PLACE WITHIN 4" OF OPENING EDGE. EXTEND BARS 48 BAR DIAMETERS PAST EDGE OF OPENING OR EXTEND AS FAR AS POSSIBLE AND PROVIDE 90' STANDARD HOOK AT END. 18. PROVIDE HORIZONTAL BAR WITHIN 3° OF TOP AND BOTT. OF WALL AND PROVIDE VERTICAL BAR AT ALL WALL CORNERS AND ENDS. YORK ENGINEERING INC. SPECIFICATIONS IS LIMITED TO THE STRUCTURAL DESIGN OF THE MAIN SUPPORTING ELEMENTS OF THIS STRUCTURE. NO OTHER DISCIPLINES OF THIS STRUCTURE INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, ELECTRICAL, PLUMBING, MECHANICAL WERE NOT REVIEWED FOR CODE COMPLIANCE OR COMPATIBILITY WITH THE DESIGN. THE PURPOSE OF THIS ENGINEERING IS TO HELP REDUCE STRUCTURAL DAMAGE AND LOSS OF LIFE DUE TO SEISMIC ACTIVITY AND/OR HIGH WIND CONDITIONS. NOTE: THIS ENGINEERING ASSUMES THAT THE CLEARANCE & SETBACK REQUIREMENTS LISTED IN IRC SECTION R403.1.7 ARE MET. IF THESE PROVISIONS ARE NOT MET, CONTACT THE ENGINEER FOR FURTHER DESIGN. NOTE: THIS ENGINEERING ASSUMES THAT THE SITE IS STABLE HAVING NO GLOBAL STABUTY CONCERNS OR HAZARDS. IF THIS IS NOT TRUE, CONTACT SOILS ENGINEER AND PROVIDE SOILS/SLOPE STABILITY REPORT TO YORK ENGINEERING FOR REVIEW AND FURTHER DESIGN. F NOTE: S131X30 BOLTS CI POST -INSTALLED. BOLTS CAST -IN-PLACE. DIMENSIONS SHOWN RE OF BOLT. REV1510N5 DATE: FOOTING SCHEDULE: DESCRIPTION: TYPE WIDTH LENGTH THICK REINFORCEMENT F-15 16" CONT. 8" NOT REQUIRED F-20 20" CONT. 8" (2) # 4 BARS CONT. NOTE: FOOTING REINFORCEMENT IN THIS SCHEDULE AND NOTED ON PLANS IS BOTTOM REINFORCING U.N.O. AND SHALL BE PLACED IN BOTTOM 1/2 OF FOOTING THICKNESS, WITH 3" CONCRETE CLEAR COVER, MIN. YORK ENGINEERING INC. SPECIFICATIONS IS LIMITED TO THE STRUCTURAL DESIGN OF THE MAIN SUPPORTING ELEMENTS OF THIS STRUCTURE. NO OTHER DISCIPLINES OF THIS STRUCTURE INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, ELECTRICAL, PLUMBING, MECHANICAL WERE NOT REVIEWED FOR CODE COMPLIANCE OR COMPATIBILITY WITH THE DESIGN. THE PURPOSE OF THIS ENGINEERING IS TO HELP REDUCE STRUCTURAL DAMAGE AND LOSS OF LIFE DUE TO SEISMIC ACTIVITY AND/OR HIGH WIND CONDITIONS. NOTE: THIS ENGINEERING ASSUMES THAT THE CLEARANCE & SETBACK REQUIREMENTS LISTED IN IRC SECTION R403.1.7 ARE MET. IF THESE PROVISIONS ARE NOT MET, CONTACT THE ENGINEER FOR FURTHER DESIGN. NOTE: THIS ENGINEERING ASSUMES THAT THE SITE IS STABLE HAVING NO GLOBAL STABUTY CONCERNS OR HAZARDS. IF THIS IS NOT TRUE, CONTACT SOILS ENGINEER AND PROVIDE SOILS/SLOPE STABILITY REPORT TO YORK ENGINEERING FOR REVIEW AND FURTHER DESIGN. F NOTE: S131X30 BOLTS CI POST -INSTALLED. BOLTS CAST -IN-PLACE. DIMENSIONS SHOWN RE OF BOLT. REV1510N5 DATE: # DESCRIPTION: BY: 4/28/2021 01 ADDED GRADE BEAM FOR POWDER BATH HD 5'-24„ O - F31_ , O NOTE: ALL CONTINUOUS FOOTINGS ARE 16" WIDE X 8" DEEP (F-16) UNLESS NOTED OTHERWISE 16,_4„ P-42 11„ W -10a" 6,_4„ 1' 42 11•, l,�la„ 16,_4„ 1'-101, (o�ya• (o� (O -*- °VO• ° � yO• S 'b 3b ND p�pJ� 13�� apo`' ND '�o �� ti��� ND u �Q1A o � yoGs cp�� 7 NOTE %"0 ALL -THREAD DRILLED & EPDXIED 8" INTO FOUNDATION ND ND ND ° ND - 0-*, 1 �9 e N � N ti3�9 NON-STRUCTURAL SLAB ON GRADE J. �ry°9 NON-STRUCTURAL SLAB ON GRADE I` NON-STRUCTURAL SLAB ON GRADE cq 0 -*- O ND 9 STEP I T.O.W. 8" 5'-24„ O - F31_ , STEP T.O.W. 8" 4'-92 3,_0„ L 7 17 Y� F . �99q#�° ND OO�IIN (�OeT a ° CBi�• N N -STRUCTURAL SLAB ON GRADE Q N a 9 ° it 0:' -STRUCTURAL SLAB ON GRADE e0 •<y LL ry 9� L Eq Q .11 16"X8" GRADE ^m BEAM W/ (2) #4 BARS CONTINUOUS �0 TBE ^o, O 11 1T BE a 4, 44 ND— CENTER Ll CONCRETE gyp' O.W. HAUNCH (TYP)u O.W. 2„ O STEP 3,-6" X94 ° 16,-o-„ NOTE: ALL CONTI OU 49.0 FOOTINGS ARE 16" WI X 8" 36'-02-'" DEEP (F-16) UNLESS NOTED OTHERWISE P2 -E LOT 15 7867 WEST 43RD 16"X8" GRADE BEAM W/ (2) #4 BARS CONTINUOUS 0.*. 4.0. 11 ND ••�• ti3g°j ND L -Z 12" T.O.W. 1„ 16'4" NOTE: %"4 ALL -THREAD DRILLED & �B O EPDXIED 8" INTO FOUNDATION 56'-6" P1 -I LOT 14 7863 WEST 43RD io 6n co 16"X8" GRADE 0 BEAM W/ (2) #4 BARS CONTINUOUS 11" NON-STRUCTURAL SLAB ON GRADE IND > \\\1 9. 442ND 10,-18, O 'O NOTE: SBiX30 BOLTS CANNOT BE POST -INSTALLED. BOLTS MUST BE CAST -IN-PLACE. DIMENSIONS SHOWN ARE TO CENTER OF BOLT. z0' -5a" P3 -E LOT 13 7855 WEST 43RD FOOTING/FOUNDATION PLAN SCALE: 1/4" =1'-0" 00* STEP .O.W.12" STEP .0.W.12' ro _T 0 o) m O •- ��rtFN o'•�F r Ir a r� a r r r , r 1'-%,04/28/2021 U] O O LLJ c) 0 LLJ Elf 0 Q u o Ul �J -i y) J O Q m W O Lo �;: LLT U) I- CD (n (Uo 00 00 0 0 Z I-- < LLJ O ro w J 00 = Q Ln Ln U GO r - \N heat 0 co F I SITE SPECIFIC PLOT PLAN NOTES: LOT = 13 TOS = 23.8 GARAGE SLAB =22.1 LOWERED FINISH GRADE ALONG HOUSE POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINAGE LOT = 14 TOS = 23.8 GARAGE SLAB =21.9 LOT = 15 TOS = 23.1 GARAGE SLAB =21.7 REVISIONS: 10.09.20 - ADDRESSES CORRECTED - AL. 10.13.20 - REDLINES PER DAVID KENDALL - AL. 10.21.20 - LABEL RAMPS AND ADA UNITS - AL. Reviewed for Zoning Compliance by the City of Wheat Ridge Planning Division APPROVED BY: DATE: 5/10/2021 COMMENTS: 0 20 40 SCALE: 1"=20' MODEL OPTIONS: SUBDIVISION: YARROW GARDENS FILING NO. 4 COUNTY: JEFFERSON CITY: WHEATRIDGE ADDRESS: O THB WestRidge LLC PLOT PLAN CURB I eo oe2.3 CONC: DRIVE o ®''DRIVE'" „GONG e CONC. o DRIVE 20 w 21.9 165 c 22.1 20.0 e' w0 T05=54228 p TOS -5422 80 15S " -}9'14 013 1,117 SOFTO O X825 SOFT O O 1,558 S( -CAR - 1 -CAR 2 O GARAGE O o 2 -CAR GARAGEto 4.e #7863 GARAGE q o #7867 Wm�3 w M #7855 MR, W �a 20.011.9 20.0 YARROWGARDEvs(O YARD—cPRDENS P1 -I 'o F PRI 94 0v FlFDDTP NT=,20 r�s=s 3.a�Z IOS 423 2.3 ' .1�o �, ,; �, !° YARROW GARDENS P3-E - FooTPRINT=leo TOS=5423.8 o r a t2z N 3 s 123.12 > 5 23.24 Sal I • PLOT PLAN NOT TO BE USED FOR EXCAVATION PLAN OR FOUNDATION PLAN LAYOUT. • PLOT PLAN SUBJECT TO APPROVAL BY ZONING/BUILDING AUTHORITY PRIOR TO STAKEOUT. • EASEMENTS DISPLAYED ON THIS PLOT ARE FROM THE RECORDED PLAT AND MAY NOT INCLUDE ALL EASEMENTS OF RECORD. • PLOT PLAN MUST BE APPROVED BY BUILDER PRIOR TO ORDERING STAKEOUT • LOT CORNER ELEVATION CHECK. 09 26-19 T: T, j,,ts ARROWGARDENSP3\YARROWGARDENSP3. dug 10AlA02073697 AM, 8�, LOT 1315 BLOCK 3 LOT ADDRESS 13 7855 WEST 43RD PLACE 14 7863 WEST 43RD PLACE 15 7867 WEST 43RD PLACE Reviewed by the City of Wheat Ridge 1I,1i Engineering Division = NO EXCEPTIONS TAKEN BY: Jordan Jefferies DATE: 6/14/2021 COMMENTS: A grading certificatin with ILC or updated CCP required prior to CO W heat O nj� C m J O 61G7�dfn9 LEGEND LOWERED FINISH GRADE: X® HOUSE X57 -XI PORCH ® GARAGE/CRAWL SPACE FX--Xl FOUNDATION STEP @x' CONCRETE RISER COUNT CONCRETE ELEVATION [xx.x] GRADING PLAN ELEVATION C sAX.xx DIENTERO C. CURB STOP AT (XX.xx) DIRT/CONC. ELEVATION AT CENTER OF METER PIT urveying, Inc. vnmm.aea,s•..bLn nss South Yosemite Street 1100 Centennial, CO 80112 : (303) 850-0559 Fax: (303) 850-0711 il: infoObisurvev.nef okW heal i A.G. WASSENAAR, INC. � oc Gmg U�N\j December 6, 2018 Revised May 27,, 2020 TH Yarrow, LLC 1875 Lawrence Street, Suite 900 Denver, Colorado 80202 Attention: Mr. Jay Garcia Subject: Soil and Foundation Study Proposed Residential Structure Lots 13-15, Block 3 Yarrow Gardens, Filing 3 Wheat Ridge, Colorado Project Number 185529 Purpose As requested, A. G. Wassenaar, Inc. (AGW) performed a soil and foundation study at the subject site. The purpose of our study was to observe subsurface conditions encountered and to recommend geotechnical design criteria for the design and construction of the foundation for the proposed triplex residential structure. For purposes of this study, we understand and assume the overexcavation recommendations provided in our report, "Geotechnical Site Development Study for Proposed Townhome Development, Yarrow Gardens, Northwest of West 42nd Avenue and Yarrow Street, Wheat Ridge, Colorado", for the subject site,, AGW Project Number 181182,, dated May 11,, 2018,, have been followed. Density -compaction test reports (AGW Project Number 181182) were considered during the preparation of this study. The fill materials tested were placed in general accordance with the requirements of HUD Data Sheet 79G. This letter presents a summary of our findings and recommendations. Proposed Construction The proposed structure will be up to three stories supported upon a reinforced concrete foundation. It is our understanding no below grade areas are planned. The structure will be wood framed with a slab -on -grade or structural slab -on -void beneath the living areas. If plans change, the recommendations in this report must be reviewed by AGW prior to design and construction of the foundation. Subsurface Conditions The field exploration included drilling two 4 -inch diameter auger borings at the approximate diagonal corners of the anticipated building footprint. The subsurface conditions encountered are shown on Figures 1 and 2,, including the results of penetration tests at the locations of sampling. Laboratory Testing Samples obtained during drilling were returned to the laboratory. They were visually classified and testing was assigned to selected samples in an effort to evaluate the engineering properties of the subsurface materials encountered. The test results are summarized on Figures 1 and 2. Based upon 2180 South Ivanhoe Street,, Suite 5 • Denver, Colorado 80222 www.agwco.com 9 Phone 303-759-8100 of W head p. U fico visual observation of the subsurface con%io;4 encountered and laboratory testing for this and/or adjacent lots, it is our opinion that the *4urWe`'materials generally exhibit low potential for expansion and compression. Refer to the Colo ado Geological Survey Special Publication 43 for a description of expansive soils and their impact on structure performance. Foundation Recommendations Based on our evaluation of the subsurface conditions, the proposed structure may be founded upon spread or pad -type footings bearing on the natural undisturbed soils or on properly placed and compacted fill. The footings should be designed for a maximum bearing pressure of 2,000 psf. Footing dimensions and foundation structural elements should be determined by a structural engineer. Concrete in contact with the subsurface materials may be designed for negligible (SO or RSO) sulfate exposure as defined by either ACI 318 (Table 19.3.1.1) or ACI 332 (Table 5.2.1) as determined from the appropriate building code for this jurisdiction. Bearing materials loosened by machine excavation should be removed prior to placing footing concrete. Occasionally, pockets of dry, hard fill or very moist, soft fill may be encountered in the foundation excavation. If this condition occurs, the footings should extend to properly moisture treated fill. Exterior footings should bear at least 3 feet below exterior grade for frost protection. The bearing materials beneath footings should be protected from freezing during construction. All footing excavations should be observed by AGW prior to placement of concrete. The foundation walls backfilled with on-site materials should be designed for a lateral earth pressure based upon an equivalent fluid density of 60 pounds per cubic foot (pcf) for the "at rest" condition or 45 pcf for the "active" condition. The "active" condition should only be used where wall movements of at least 0.5% of the wall height are allowed. These values have been provided without considerations for sloping backfill, surcharge loading or hydrostatic pressures. Construction of a drain system and proper surface drainage as discussed later in this report may lower the potential of developing hydrostatic pressure in the backfill materials. Minor cracking of concrete foundation walls should be expected. Concrete Slab Construction A concrete slab performance risk evaluation was conducted in general conformance with industry guidelines for the local area. The risk assessment of a site for potential movement is not absolute; rather, it represents a judgment based upon the data available and our experience in the area. Movement of foundations and concrete flat work will occur with time in low to very high risk areas as the soil moisture content increases. On low and moderate rated sites, slab movements of up to 3 inches across the slab with slab cracking of up to t/a-inch in width and/or differential are considered normal. The damage generally increases as the risk assessment increases and as the depth of wetting increases. It must be understood, however, that assessing risk is an opinion. There is currently no type of testing or correlation of factors that will definitively predict the amount of heave that a floor slab will exhibit. Therefore, it may be possible that heaves less than or in excess of what is considered "normal' may be experienced. For sites with a risk assessment of high or very high, we recommend an interior floor system engineered for expansive soils be constructed. In addition, a structurally supported floor AGW Project Number 185529 December 6, 2018; Revised May 27, 2020 TH Yarrow, LLC Page 2 system is recommended for all finished areas or any other areas where floor movements cannot be tolerated. Based upon our evaluation of the subsurface conditions at this site, it is our opinion that the slab performance risk for this site is low. If this risk of movement is not acceptable, structurally supported interior floors should be constructed. A slab -on -grade floor can be used provided the risk of movement and cracking is acceptable to the Client and the Homeowner. If the Homeowner cannot tolerate slab movement, they should request that a structurally supported floor be installed. If the Builder and/or Homeowner desires to construct a concrete slab -on -grade and accepts the risk of slab movement, slabs supported by the expansive subsurface materials should be constructed using the following criteria: 1. Slabs should be separated from exterior walls and interior bearing members with a joint which allows free vertical movement of the slab. 2. The use of slab bearing partitions should be minimized. Where necessary, slab bearing o \Nheat� partitions should be constructed with a minimum 2 -inch void space. Doorways should `A � also be designed to allow vertical movement of the slab. Drywall should not be in v co contact with the slab. Stairways bearing upon the slab should be constructed in such a way as to allow at least 2 inches of slab heave. In the event of slab heave, the O . o,' movement should not be transmitted directly through the partitions to the remainder of the structure. The Homeowner should monitor the partition voids and other connections and re-establish the voids before they close to less than 1/2 -inch. 3. Plumbing and utilities should be isolated from the slab and be provided with flexible connections. The Homeowner must maintain these connections. 4. Where a forced air heating system is used and the furnace is located on the slab, we recommend provision for a collapsible connection between the furnace and the duct work to allow for at least 3 inches of slab heave. Utility connections should also be provided with flexible connections capable of accommodating the same magnitude of movement as specified above. 5. Frequent control joints should be provided in the slab to reduce problems associated with shrinkage cracking and curling. We recommend additional control joints be located approximately 3 feet away from and parallel to the foundation walls. Following these recommendations should reduce damage caused by movement of the floor slab. The void spaces recommended are not intended to predict total slab movement. Care should be taken to monitor and reestablish partition voids and flexible connections when necessary. We are available to provide further consultation regarding concrete slab performance risk assessments. If a slab -on -grade is finished, cosmetic damage should be expected (i.e., drywall cracks, sticking doors, floor tile cracking). Fill Placement Any fill placed beneath the foundation and slabs -on -grade should be well compacted. Prior to placement of fill, the ground surface should be scarified a minimum of 6 inches or pipes in trenches should be properly bedded. The new fill should be of similar soil type as the existing subgrade material. New fill should be placed in maximum 8 -inch loose lifts. The scarified ground surface and the new fill should be compacted to a minimum of 95% of Standard Proctor (ASTM D698) maximum AGW Project Number 185529 December 6, 2018; Revised May 27, 2020 TH Yarrow, LLC Page 3 dry density for cohesive soils or Modified Proctor (ASTM D1557) maximum dry density for granular soils. The moisture content of the compacted material should be between optimum and 4% over optimum moisture content for cohesive soils or within 2% of optimum moisture content for granular soils. Density compaction testing must be performed upon any new fill placed beneath the foundation of the structure. Backfill around the foundation should be moistened and compacted in such a manner as to reduce future settlement. Subsurface Drainage It is our understanding that no below grade areas are planned for the proposed three -unit townhome. Present ground water conditions, in our opinion, should not be a problem for the proposed structure. We believe if the ground surface and roof drainage are properly cared for, no subsurface drainage systems should be necessary unless below grade areas are planned. Surface Drainage The wetting of foundation soils and/or bedrock materials may be reduced by carefully planned and maintained surface drainage. The following recommendations should be implemented during construction and maintained by the Homeowner or Homeowners Association after the structure is completed: p��. Excessive wetting or drying of the open foundation excavation should be avoided as v � much as practical during construction. 2. The ground surface surrounding the exterior of the foundation should be maintained in such a manner as to provide for positive surface drainage away from the foundation. At completion of construction, we recommend a minimum fall away from the foundation of 6 inches in the first 5 feet. This slope should be continuous across the backfill zone. 3. Areas which settle should be filled as soon as possible in order to maintain positive drainage away from the foundation. 4. If lawn edging is used around the exterior of the foundation, it should be constructed in a manner to prevent ponding of surface water in the vicinity of the backfill soils. 5. Drainage swales should be constructed and maintained a minimum of 5 feet away from the foundation on side yards and 15 feet away from the foundation on back and front yards. Natural drainage swales should maintain a slope of at least 2% off of the lot. Swales must not be blocked by fences, landscaping, paths or other Homeowner or Homeowners Association installed items. 6. Roof downspouts and drains should discharge well beyond the limits of foundation backfill. 7. Watering adjacent to the foundation should be reduced as much as practical. Landscaping which requires excessive watering should not be located within 5 feet of foundation walls. Sprinkler lines, zone control boxes, and drains should be located outside the limits of the foundation backfill. Sprinkler heads should be positioned such that the spray does not fall within 5 feet of foundation walls. 8. Plastic membranes should not be used to cover the ground surface immediately surrounding the foundation. These membranes tend to trap moisture and prevent normal evaporation from occurring. We recommend the use of a weed suppressant geotextile fabric. AGW Project Number 185529 December 6, 2018; Revised May 27, 2020 TH Yarrow, LLC Page 4 Limitations We believe the professional judgments expressed in this report are consistent with that degree of skill and care ordinarily exercised by practicing design professionals performing similar design services in the same locality, at the same time, at the same site and under the same or similar circumstances and conditions. No other warranty, express or implied, is made. The location of the test borings drilled and the laboratory testing performed for this study were designed to obtain a reasonably accurate picture of subsurface conditions for design purposes. Variations in subsurface conditions not indicated by the borings are possible and expected. Therefore, we should be retained to observe the foundation excavation and construction. If unexpected subsurface conditions are observed by others during construction, we should be called to review our recommendations. This report was prepared for the exclusive use of our Client for the sole purpose of providing geotechnical design criteria for the subject structure based upon the existing site conditions as encountered. The conclusions and recommendations contained in this report shall not be considered valid for use by Others without written authorization from AGW. In addition, the state of practice in geotechnical engineering is constantly evolving. Therefore, findings presented in this report should be reviewed and revised, if necessary, prior to actual construction. The recommendations provided in this report are based upon the specified extents of the overexcavation for the original building footprint. The future Homeowner or Homeowners Association should not construct any additions to the structure utilizing the recommendations given in this report. Additional studies must be provided if any additions are to be constructed. If we can be of further service in discussing the contents of this letter or in analysis of proposed structure from the soil and foundation viewpoint, please call our office. o� W heat l 6'G�7a'ing DN hoc Attachments: Figures 1 and 2 Sincerely, o�p�C Ll cF,y A. G. Wassenaar,A —- - �:U�Q oyy:o ;� 30731 A; Michael R. Conner, P. Senior Engineers/ONA.. Digitally signetl by: Michael R Conner Date: 2020.05.27 17:46:46 -07'00" MRC/bab AGW Project Number 185529 TH Yarrow, LLC December 6, 2018; Revised May 27, 2020 Page 5 e B3 L13 V ''' `4co r4,o'AGW A.G. WASSENAAR, INC. CLIENT TH Yarrow LLC. ainnX1jo PROJECT NAME Yarrow Gardens, Filing 3 PROJECT NUMBER 185529-1 PROJECT LOCATION Wheat Ridge, Colorado DATE DRILLED May 15, 2019 GROUND WATER LEVELS: DRILLING METHOD 4 -inch Solid Stem Auger AT TIME OF DRILLING Dry NOTES Test boring drilled in the southeast corner 2' below proposed grade 6 DAY(S) AFTER DRILLING 13 feet ATTERBERG Lu o w o LIMITS U a}- _O Lu w O MATERIAL DESCRIPTION o= O w w �' o ~ E~ v w �•• (D a�`� coo �z �O" * a � � cn D O a z j 0 O U Fill, sand and clay, medium dense to stiff, silty, moist, mottled brown MC 6/ 12 115 17 -0.3 5 MC 11/12 106 15 -0.3 10 Clay (weathered claystone), stiff, silty, sandy, moist, light olive to rust Claystone (bedrock), medium hard, silty, sandy, iron stained, moist to very moist, light olive to rust MC 32/ 12 109 21 2.7 15 Sandstone (bedrock),very hard, poorly cemented, silty, clayey, with 20 claystone lenses, iron stained, moist to very moist, olive to rust MC 1 50 / 8 Bottom of borehole at 24.7 feet. Figure 1 e ' V '' `4co r4,a'AGW A.G. WASSENAAR, INC. O c CLIENT TH Yarrow LLC. G�7dii7�A PROJECT NAME Yarrow Gardens, Filing 3 PROJECT NUMBER 185529-2 PROJECT LOCATION Wheat Ridge, Colorado B3 DATE DRILLED May 15, 2019 GROUND WATER LEVELS: DRILLING METHOD 4 -inch Solid Stem Auger AT TIME OF DRILLING Dry NOTES Test boring drilled in the northwest corner 6 DAY(S) AFTER DRILLING 11.5 feet ATTERBERG wa o L o Oz LIMITS =a^ U 2 � � CL Ziz v ~�` D� JQ Luw O MATERIAL DESCRIPTION o a w L c o U E� U w o.. Z�L mU oz moo" a� (D } 2:00 (Y �� �� c�nz ��cn D a~ ^ E 1 10 15 n Fill, sand and clay, medium dense to stiff, silty, moist, mottled brown Fill, sand and clay, medium dense to stiff, silty, with some processed claystone and sandstone, moist, mottled brown to mottled gray silty, sandy, moist, light olive to rust Claystone (bedrock), medium hard, silty, sandy, iron stained, moist to very moist, light olive to rust Bottom of borehole at 20.0 feet. Figure 2 u MC 1 15 / 12 1 105 1 16 1 -0.3 1 u MC 1 19 / 12 1 96 1 32 1 1.3 1 u MC 1 34 / 12 1 93 1 27 1 2.9 1 MC 1 40 / 12 Reviewed for Zoning Compliance by the , ► . City of Wheat Ridge Planning Division APPROVED BY: DATE: 5/10/2021 COMMENTS: Complies with approved master permits and site plan WSP-20-03 No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. Reviewed by the City of Wheat Ridge Engineering Division APPROVED Jordan Jefferies BY: DATE: 5/14/2021 COMMENTS: A grading certification with ILC or updated CCP required prior to CO F I N I S •1'41. k ut' of ti� heat p' -d C.t?�a+t�Nrn• l�tvut�f'tttt�t APPROVED Rayls*W_for_r7oft r"qaidbml_ Mike Theisen 05/17/2021 Plans Exam ' 0~0014" mwfw" a�ao�t#nii e�.al�7I�4.Q-��'a(� e+»siwr 6e �•�. qi tea �'n"ti'h'u a� !k".i�Ale,P �n,or a�a�r� oL�wv� IAv� p.ra.....g•,laq�►s.v.tt;si'ria..a�r orsoisi etir,�n�r,us � n�,w.� cp�19s ar u[�Ar'vpl►iatat9tt � Use �' Mst�+aai lbr post P1 ■ FINISHED DO -MORE COVER SHEET MAIN LEVEL 594 SF UPPER LEVEL 540 SF ENTRY LL 96 SF POWDER 43 SF A1.10 1,273 SF UNFINISHED 3-PLEX-A UPPER LEVEL BUILDING PLAN DO MORE 141 SF SPACE 3-PLEX-A BUILDING ELEVATIONS GARAGE 314 SF U 0 455 SF P2 -E FINISHED CONSTRUCTION MAIN LEVEL 639 SF UPPER LEVEL 671 SF 1,310 SF UNFINISHED 2 -CAR GARAGE 460 SF ENTRY/DO 260 SF MORE SPACE DECK 31 SF ENTRY ML 81 SF 832 SF P3 -E FINISHED MAIN LEVEL 780 SF UPPER LEVEL 732 SF ENTRY LL 88 SF POWDER 44 SF 1,644 SF UNFINISHED 2 -CAR GARAGE 460 SF DO -MORE 188 SF SPACE DECK 30 SF AO 678 SF YARROW GARDENS STACKED TOWNHOMES 0 -4 -A i I: I kvk0l;12 UNOW1, G TYPE 3A BLOCK 3, LOTS 13- 15 WHEAT RIDGE, COLORADO THRIVE HOME BUILDERS Homes that do more. I N D E X O F D R A W I N G S DRAWING INDEX SHEET NUMBER SHEET NAME AO DO -MORE COVER SHEET G1 CODE ANALYSIS G2 GENERAL NOTES G3 ARCHITECTURAL SITE PLAN A1.01 3-PLEX-A LOWER LEVEL BUILDING PLAN A1.10 3-PLEX-A MAIN LEVEL BUILDING PLAN A1.20 3-PLEX-A UPPER LEVEL BUILDING PLAN A1.30 3-PLEX-A ROOF PLAN A3.01 3-PLEX-A BUILDING ELEVATIONS A3.02 3-PLEX-A BUILDING ELEVATIONS B U I L D I N G A D D R E SS BLOCK 3, LOTS 13-15 BUILDING TYPE 3A LOT ADDRESS 13 7855 WEST 43RD PLACE 14 7863 WEST 43RD PLACE 15 7867 WEST 43RD PLACE E S 0 w a 0 z W 0 nu 0 0 0 th rive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 W W W.THRIVEHOMEBUI LDERS.COM GoddenISudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 E Nl heal o 0 LU U 0 V) L ! O Z O O U W Z lJ 3� 0 V O� LLJ O oe -3: CONSTRUCTION SET ISSUE DATE 10/22/2020 DO -MORE COVER SHEET AO 0 f h rive HOME BUILDERS Homes that do more THRIVE HOME CODE ANALYSIS FIRE-RESISTANT CONSTRUCTION 40 GoddenjSudik -R302.2 TOWNHOUSES: PROJECT DIRECTORY 303.455.4437 www.goddensudik.com -R302.2.1 CONTINUITY: FIRE -RESISTANCE -RATED COMMON WALL SEPARATING EACH UNIT SHALL BE Suite 250 Centennial, CO 80111 APPLICABLE CODES & STANDARD: CONTINUOUS FROM FOUNDATION TO UNDERSIDE OF ROOF SHEATHING AND FIRE -RESISTANCE RATING LU 2018 INTERNATIONAL BUILDING CODE SHALL EXTEND THE FULL LENGTH OF THE COMMON WALL. ARCHITECT CIVIL ENGINEER STRUCTURAL ENGINEER 0 V O W O oe -3: 2018 INTERNATIONAL RESIDENTIAL CODE GoddenlSudik Architects Baseline Engineering EV Studio SET 2018 INTERNATIONAL ENERGY CONSERVATION CODE -R302.2.2.2 PARAPETS... EXCEPTION: PARAPETS WILL NOT BE REQUIRED... WHEN THE ROOF IS COVERED WITH 5975 S. Quebec St., Suite 250 1950 Ford Street 1117 Cherokee Street 2018 INTERNATIONAL MECHANICAL CODE A MINIMUM CLASS C ROOF COVERING, AND THE ROOF DECKING OR SHEATHING IS OF NONCOMBUSTIBLE Centennial, CO 80111 Golden, CO 80401 Denver, CO 80204 303.455.4437 303.940.9966 303.670.7242 2018 INTERNATIONAL PLUMBING CODE MATERIALS OR APPROVED FIRE -RETARDANT -TREATED WOOD FOR A DISTANCE OF 4 FEET ON EACH SIDE OF Contact: Paul Brady Contact: Noah Nemmers Contact: Ross Maxwell 2018 INTERNATIONAL FIRE CODE THE COMMON WALL. 2018 INTERNATIONAL FUEL GAS CODE 2017 NATIONAL ELECTRIC CODE -R302.2.4 STRUCTURAL INDEPENDENCE: OWNER LANDSCAPE ARCHITECT EXCEPTION 1. FOUNDATIONS SUPPORTING EXTERIOR WALLS OR COMMON WALLS. Thrive Home Builders Redland OCCUPANCY: TOWNHOUSE EXCEPTION 2. STRUCTURAL ROOF AND WALL SHEATHING FROM EACH UNIT MAY FASTEN TO THE 1875 Lawrence Street, Suite 900 1500 West Canal Court PER THE INTERNATIONAL BUILDING CODE EXCEPTION (101.2) DETACHED ONE- AND TWO-FAMILY DWELLING COMMON WALL FRAMING. Denver, CO 80202 Littleton, CO 80120 303.707.4439 720.283.6783 Gl AND MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES) NOT MORE THAN THREE STORIES ABOVE GRADE EXCEPTION 3. NONSTRUCTURAL WALL AND ROOF COVERINGS Contact: Eric Sung Contact: Susan Wade PLANE IN HEIGHT WITH A SEPARATE MEANS OF EGRESS AND THEIR ACCESSORY STRUCTURES SHALL COMPLY EXCEPTION 4. FLASHING AT TERMINATION OF ROOF COVERING OVER COMMON WALL WITH THE INTERNATIONAL RESIDENTIAL CODE. -R302.4.1 THROUGH PENETRATIONS: THROUGH PENETRATIONS OF FIRE -RESISTANCE -RATED WALL HEIGHT AND NUMBER OF STORIES: ASSEMBLIES SHALL COMPLY WITH SECTION R302.4.1.1 OR R302.4.1.2 STORIES: 3 STORIES (MAX) GARAGES: HEIGHT: 32 FT MAX OR PER VARIANCE APPROVAL -R302.5.1 OPENING PROTECTION: DOORS BETWEEN GARAGE AND RESIDENCE SHALL BE MINIMUM OF 1 3/8" THICK SOLID WOOD DOORS, SOLID OR HONEYCOMB CORE STEEL DOORS OR 20 MINUTE FIRE -RATED 2018 INTERNATIONAL RESIDENTIAL CODE PROVISIONS DOORS EQUIPPED WITH A SELF-CLOSING DEVICE. R302.1 CONSTRUCTION, PROJECTIONS, OPENINGS AND PENETRATIONS OF EXTERIOR WALLS OF -R302.5.2 DUCT PENETRATION: DUCTS IN THE GARAGE AND PENETRATING THE WALLS OR CEILING DWELLINGS AND ACCESSORY BUILDINGS SHALL COMPLY WITH TABLE R302.1 SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM No. 26 GAGE EXCEPTION 1. WALLS, PROJECTIONS, OPENINGS OR PENETRATIONS IN WALLS SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE PERPENDICULAR TO THE LINE USED TO DETERMINE THE FIRE SEPARATION DISTANCE R302.6 DWELLING/GARAGE FIRE SEPARATION: PER TABLE R302.6 - DOES NOT APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL TABLE R302.1(1) EXTERIOR WALL TABLE R302.6 DWELLING/GARAGE SEPARATION MINIMUM FIRE -RESISTANCE MINIMUM FIRE SEPARATION EXTERIOR ELEMENT RATING DISTANCE SEPARATION MATERIAL FROM THE RESIDENCES AND ATTICS NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT APPLIED TO FIRE -RESISTANCE RATED 1 HOUR TESTED 0 FEET ASTM E 119 OR UL 263 THE GARAGE SIDE WALLS NOT FIRE -RESISTANCE RATED 0 HOURS >_ 5 FEET FROM ALL HABITABLE ROOMS ABOVE THE NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIVALENT NOT ALLOWED N/A < 2 FEET GARAGE FIRE -RESISTANCE RATED 1 HOUR ON THE > 2 FEET < 5 FEET STRUCTURE(S) SUPPORTING FLOOR/CEILING PROJECTIONS UNDERSIDE ASSEMBLIES USED FOR SEPARATION NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT REQUIRED BY THIS SECTION NOT FIRE -RESISTANCE RATED 0 HOURS >_ 5 FEET NOT ALLOWED N/A < 3 FEET GARAGES LOCATED LESS THAN 3 FEET NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT APPLIED TO OPENINGS IN WALLS 25% MAX OF WALL AREA 0 HOURS 3 FEET FROM A DWELLING UNIT ON THE SAME LOT THE INTERIOR SIDE OF EXTERIOR WALLS THAT ARE WITHIN THIS AREA UNLIMITED 0 HOURS 5 FEET COMPLY W/ R302.4 < 3 FEET LIGHT, VENTILATION AND HEATING PENETRATIONS ALL NONE REQUIRED 3 FEET -ALL APPLICABLE ROOMS WILL COMPLY WITH REQUIREMENTS IN SECTION R303. -GARAGES WILL NOT BE MECHANICALLY HEATED. MEANS OF EGRESS TABLE R302.1(2) EXTERIOR WALL - DWELLINGS WITH FIRE SPRINKLERS -SEPARATE MEANS OF EGRESS WILL BE PROVIDED FOR EACH UNIT. MINIMUM FIRE -RESISTANCE MINIMUM FIRE SEPARATION EXTERIOR ELEMENT RATING DISTANCE -AUTOMATIC SPRINKLER SYSTEM WILL ONLY BE INSTALLED IN SPECIFIC UNITS AS NOTED ON SHEET G3. 1 HOUR TESTED FIRE -RESISTANCE RATED 0 FEET ASTM E 119 OR UL 263 -FIRE SPRINKLER SYSTEM SHALL BE DESIGNED & INSTALLED IN ACCORDANCE WITH SECTION P2904 WALLS OR NFPA NOT FIRE -RESISTANCE RATED 0 HOURS 3 FEET D. CA/ACCESSIBILITY NOT ALLOWED N/A < 2 FEET PER FAIR HOUSING ACT: MULTISTORY DWELLING UNITS ARE NOT COVERED BY THE GUIDELINES WITHOUT 1 HOUR ON THE PROJECTIONS FIRE -RESISTANCE RATED UNDERSIDE 2 FEET ONE OR MORE ELEVATORS. -R320.1 SCOPE: WHERE THERE ARE FOUR OR MORE DWELLING UNITS IN A SINGLE STRUCTURE, THE NOT FIRE -RESISTANCE RATED 0 HOURS 3 FEET PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL APPLY. NOT ALLOWED N/A < 3 FEET OPENINGS IN WALLS -IBC 1 107.6.3 GROUP R-3: WHERE THERE ARE FOUR OR MORE DWELLING UNITS IN A SINGLE STRUCTURE, UNLIMITED 0 HOURS 3 FEET EVERY DWELLING UNIT SHALL BE A TYPE B UNIT. -R1 107.7.2 MULTISTORY UNITS: A MULTISTORY DWELLING UNITY WHICH IS NOT PROVIDED WITH ELEVATOR COMPLY W/ R302.4 < 3 FEET SERVICE IS NOT REQUIRED TO BE A TYPE B UNIT. PENETRATIONS ALL NONE REQUIRED 3 FEET DEFERRED SUBMITTALS: FIRE SPRINKLERS (DEFERRED SUBMITTAL UNDER SEPARATE PERMIT) STRUCTURAL FOUNDATION PLANS WILL BE SUBMITTED AT INDIVIDUAL LOT SUBMITTALS. 0 f h rive HOME BUILDERS Homes that do more THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM 40 GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 E\Nheal o ci GENERAL NOTES ROOF NOTES FIRE SEPARATION NOTES 1 . CODES HAVING JURISDICTION SHALL BE STRICTLY OBSERVED IN THE CONSTRUCTION OF 1 . ALL ROOF TRUSSES TO BE DESIGNED AND FABRICATED UNDER THE SUPERVISION OF A 1 . OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING THE PROJECT. ALL APPLICABLE STATE, COUNTY, AND CITY REQUIREMENTS REGARDING COLORADO LICENSED STRUCTURAL ENGINEER. PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND THE BUILDING, ZONING, ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE CODES SHALL BE 2. PROVIDE ROOF VENTS AND/OR SOFFIT VENTS AS REQUIRED PER IRC. SEE ROOF VENT RESIDENCE SHALL BE EQUIPPED WITH A SELF-CLOSING, SELF -LATCHING SOLID WOOD VERIFIED BY THE SUBCONTRACTORS BEFORE COMMENCEMENT OF CONSTRUCTION. ANY CALCULATIONS FOR "NET FREE AREA REQUIRED". DOOR NOT LESS THAN 1-3/8" IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOOR DISCREPANCIES BETWEEN THE CODE REQUIREMENT AND THE DRAWINGS SHALL BE 3. CRICKET AND SADDLES SHALL BE INSTALLED IN REQUIRED LOCATIONS PER IRC. NOT LESS THAN 1-3/8" THICK, OR 20 -MINUTE FIRE -RATED DOORS. (IRC) REPORTED TO THE BUILDER IMMEDIATELY. 4. INSTALL CONTINUOUS SOFFIT VENTS WITH OVERHANGS UNDER 24 INCHES AND SOLID 2. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC SPACE BY NOT 2. CONTACT THE BUILDER FOR CLARIFICATION OF ANY DISCREPANCIES AND/OR ERRORS SOFFIT BOARDS WITH UNDEREAVE VENTS WITH OVERHANGS OVER 24 INCHES. LESS THAN 5/8" TYPE 'X' GYPSUM BOARD APPLIED TO THE GARAGE SIDE. WHERE THE FOUND IN THE CONTRACT DOCUMENTS. ANY CHANGES TO THE CONTRACT DOCUMENTS 5. ICE AND WATER SHIELD TO BE INSTALLED PER IRC & BUILDING SPECIFICATIONS. SEPARATION IS A HORIZONTAL THE GYPSUM BOARD SHALL BE ATTACHED TO FRAMING SHALL BE REVIEWED AND APPROVED BY THE BUILDER PRIOR TO ANY CONSTRUCTION. 6. VALLEYS: CENTER A 36" WIDE STRIP OF SELF -ADHERED ICE AND WATER SHIELD IN THE VALLEY. MEMBER SPACED NO MORE THAN 16 INCHES ON CENTER AND THE STRUCTURE 3. ALL PRODUCTS SHALL BE INSTALLED PER MANUFACTURER'S INSTALLATION GUIDELINES ICE AND WATER SHIELD SHALL BE TIGHT IN THE VALLEY, WITHOUT CREASES OR WRINKLES. SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 5/8" TYPE 'X' AND/OR BUILDER DETAILS. CONTACT BUILDER WITH ANY DISCREPANCIES BETWEEN MFR'S INSTALL ROOF UNDERLAYMENT TO THE ROOF AND OVERLAP ICE & WATER SHIELD STRIP BY 6" GYPSUM BOARD OR EQUIVALENT. (IRC) AROUND STRUCTURAL ELEMENTS PROVIDE 5/8" GUIDELINES AND BUILDER PROVIDED DETAILS PRIOR TO INSTALLATION. MINIMUM. INSTALL SHINGLES IN CLOSED OR WOVEN VALLEY PER SHINGLE MANUFACTURER'S TYPE 'X' GYPSUM BOARD - TAPE AND FINISH. 4. CONTRACTOR AND APPLICABLE TRADES WORKING ON THE JOB SHALL CONSULT WITH AND SPECIFICATIONS 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING FOLLOW PREPARED SOILS REPORT RECOMMENDATIONS. 7. GENERAL UNDERLAYMENT REQUIREMENTS PER IRC AND ROOFING MANUFACTURER'S THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE 5. SEE STRUCTURAL ENGINEER'S SITE SPECIFIC FOUNDATION PLANS FOR FINAL CONSTRUCTION SPECIFICATION: (0.48 mm) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS SPECIFICATIONS. 7.1. FOR 2:12 UP TO 4:12 ROOF, PROVIDE 2 LAYERS OF BUILDER APPROVED INTO THE GARAGE. 6. CONTRACTOR TO COORDINATE TOP OF FOUNDATION WALL ELEVATIONS WITH UNDERLAYMENT. 4. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE INFORMATION INDICATED ON THESE DRAWINGS, STRUCTURAL ENGINEER'S FOUNDATION 7.2. FOR 4:12 AND GREATER, PROVIDE ONE LAYER OF BUILDER APPROVED UNDERLAYMENT. AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. (IRC) PLANS AND FINAL SITE GRADING. 8. PROVIDE DOWNSPOUTS, PER BUILDER SPECIFICATIONS, W/ ADJUSTABLE EXTENDERS TO 5. AT MECHANICAL FLUES PROVIDE DRAFT STOP AT FLOOR LEVELS, VERIFY CLEARANCE WITH 7. PROVIDE POSITIVE DRAINAGE AWAY FROM FOUNDATION PER SOILS REPORT CARRY WATER MIN. 5-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT OR MANUFACTURER, MECHANICAL ENGINEER AND LOCAL CODES. RECOMMENDATIONS OR A MINIMUM OF 10% AWAY FROM FOUNDATION FOR THE FIRST 10 PER LOCAL CODES. WHERE APPLICABLE, REFER TO CIVIL DRAWINGS FOR LOCATION OF AND 6. FLOOR ASSEMBLIES THAT ARE NOT REQUIRED BY CODE TO BE FIRE -RESISTANCE RATED, FEET. IMPERVIOUS SURFACES MAY BE SLOPE 2.5% MINIMUM AWAY FROM THE STRUCTURE CONNECTION TO THE STORM DRAIN SYSTEM. SHALL BE PROVIDED WITH A 1/2" GYPSUM WALL BOARD MEMBRANE, 5/8" WOOD FOR THE FIRST 10 FEET. STRUCTURAL PANEL MEMBRANE OR EQUIVALENT ON THE UNDERSIDE OF THE FLOOR 8. PROVIDE DAMP PROOFING ON EXTERIOR FACE OF ALL FOUNDATION WALL PER BUILDER OPENING NOTES FRAMING MEMBER. PENETRATIONS OR OPENINGS FOR DUCTS, VENTS, ELECTRICAL SPECIFICATION - FOR SINGLE FAMILY DETACHED ONLY. 1 . PROVIDE TEMPERED GLAZING IN HAZARDOUS LOCATIONS PER IRC OUTLETS, LIGHTING, DEVICES, LUMINARIES, WIRES, SPEAKERS, DRAINAGE, PIPING AND 9. PER IRC, PROVIDE 4" MIN. GRAVEL BASE OR APPROVED EQUAL UNDER CONCRETE SLAB ON 2. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOT LESS THAN SIMILAR OPENINGS OR PENETRATIONS SHALL BE PERMITTED. GRADE WITH A 6" MIN. POLYETHYLENE OR APPROVED VAPOR BARRIER WITH JOINTS LAPPED ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENINGS. EXCEPTIONS: NOT LESS THAN 6" BETWEEN GRAVEL BASE AND SLAB - FOR SINGLE FAMILY DETACHED. 3. EGRESS WINDOWS (IRC): 6.1. FLOOR ASSEMBLIES PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM. 10. PROVIDE MINIMUM CLEARANCES FOR ALL EXTERIOR WALL MATERIALS TO TOP OF GRADE PER 3.1 . EGRESS WINDOWS TO HAVE A SILL HEIGHT OF 24" MINIMUM AND 44" MAXIMUM ABOVE 6.2. FLOOR ASSEMBLIES LOCATED DIRECTLY OVER A CRAWL SPACE NOT INTENDED FOR LOCAL CODES OR A MINIMUM OF 8" (4" FOR MASONRY VENEERS). FINISHED FLOOR. STORAGE OR FUEL -FIRED APPLIANCES. 1 1 . ALL DIMENSIONS ARE TO FACE OF FOUNDATION OR ROUGH FACE OF STUDS UNLESS 3.2. SHALL HAVE 5.7 SQUARE FEET OF OPEN AREA. GRADE FLOOR MINIMUMALL 6.3. AGGREGATE AREA OF THE UNPROTECTED PORTION DOES NOT EXCEED 80 S.F. & INDICATED OR NOTED OTHERWISE. ALL MASONRY DIMENSIONS INDICATED ARE NOMINAL OPENINGS SHALL HAVE A MINIMUM OF 5 SQUARE FEET OF NET OPEN AREA. FIREBLOCKING IS INSTALLED ALONG THE PERIMETER OF THE UNPROTECTED PORTION DIMENSIONS. CONTACT THE BUILDER FOR CLARIFCATION WITH ANY DIMENSIONING ISSUES 3.3. NET CLEAR HEIGHT SHALL BE 24" MINIMUM AND NET CLEAR WIDTH SHALL BE 20" TO SEPARATE THE AREA FROM THE REMAINDER OF THE FLOOR ASSEMBLY. OR CONFLICTS. DO NOT SCALE. MINIMUM. 6.4. WOOD FLOOR ASSEMBLIES USING DIMENSION LUMBER OR STRUCTURAL COMPOSITE 12. THICKNESS OF INTERIOR WALL FRAMING IS 3 1/2" UNLESS NOTED OTHERWISE. 4. EGRESS WINDOW WELLS MUST ALLOW FULL OPERATION OF WINDOW HAVE A MINIMUM LUMBER EQUAL TO OR GREATER THAN 2X10 NOMINAL DIMENSION, OR OTHER 13. TYPICAL THICKNESS OF 2X6 EXTERIOR WALL FRAMING IS 5 1/2" UNLESS NOTED CLEAR AREA OF 9 SQUARE FEET AND A MINIMUM HORIZONTAL PROJECTION AND WIDTH OF APPROVED FLOOR ASSEMBLIES DEMONSTRATING EQUIVALENT FIRE PERFORMANCE. OTHERWISE. 36 INCHES. IF WINDOW WELL IS OVER 44 INCHES DEEP, PERMANENT STAIRS OR LADDER 7. PROVIDE FIRE -RATED EAVE PER DETAIL AS REQUIRED PER CODE -VERIFY W/ PLOT PLAN AND 14. DOOR &WINDOW CALLOUTS ARE GENERIC/NOMINAL DIMENSIONS. ACTUAL ROUGH MUST BE PROVIDED WHICH DOES NOT PREVENT OPERATION OF THE WINDOW OR FIELD CONDITIONS. OPENINGS PER MANUFACTURER'S SPECS. ENCROACH MORE THAN 6 INCHES INTO THE CLEAR AREA. (IRC) 15. ALL ANGLES ARE 450 UNLESS NOTED OTHERWISE FIRE SPRINKLER NOTES 16. ALL DOOR & WINDOW DIMENSIONS ARE SHOWN TO CENTERLINE OF R.O. UNO PLUMBING NOTES 1. AN AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN ONE- AND TWO- FAMILY 17. PLATFORM FRAME ALL WALLS TO UNDERSIDE OF BOTTOM CHORDS OF TRUSS OR JOIST. 1 . VERIFY WITH LOCAL MUNICIPALITY &INSTALL WATER -HAMMER ARRESTORS AS NECESSARY TO DWELLINGS UNLESS EXEMPTED BY LOCAL MUNICIPALITY. 18. FRAMING CONTRACTOR SHALL COORDINATE WITH THE OWNER AND ALL SERVICE LINES FOR WASHER BOX, DISHWASHER AND ICE -MAKER. WATER -HAMMER ARRESTORS 2. DESIGN &INSTALL AUTOMATIC FIRE SPRINKLER SYSTEMS PER IRC AND LOCAL CODES. SUBCONTRACTORS TO DETERMINE THE LOCATION OF ALL FIXTURES, APPLIED TREATMENTS, SHALL INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION EQUIPMENT, HARDWARE ITEMS, ETC., AND PROVIDE SOLID STRUCTURAL BLOCKING AND/OR INSTRUCTIONS. C CTIONS. IECC 2018 COMPLIANCE NOTES EXTRA FRAMING NECESSARY FOR SAFE AND SOUND ANCHORAGE AND/OR SUPPORT. 2. SUMP PIT &PUMP TO BE INSTALLED PER LOCAL CODES (IRC) AND SEALED WITH GAS-TIGHT SIMULATED PERFORMANCE ALTERNATIVE METHOD 19. PROVIDE VERTICAL AND HORIZONTAL FIREBLOCKING/DRAFTSTOPS PER LOCAL CODES REMOVABLE COVER. FIELD VERIFY LOCATION OF PIT. 1 . INSULATION - SEE SCHEDULE. 20. HABITABLE ROOMS, HALLWAYS, CORRIDORS, BATHROOMS, TOILET ROOMS, LAUNDRY 3. PROVIDE COMBUSTION AIR PER SPECIFICATION AND LOCAL CODES (IRC) TO FURNACE AND 2. WINDOWS - LOW -E, U<0.30 MINIMUM. ROOMS AND BASEMENTS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET. THE HOT WATER HEATER. 3. HEATING - FUEL -FIRED AIR DISTRIBUTION, NATURAL GAS, 92.1 AFUE MINIMUM. REQUIRED HEIGHT SHALL BE MEASURED FROM THE FINISH FLOOR TO THE LOWEST 4. WATER CLOSETS AND LAVATORIES SHALL BE SET 15" FROM ITS CENTER TO ANY SIDE WALL, 4. COOLING -ELECTRIC AIR CONDITIONING UNIT, 13.0 SEER MINIMUM. PROJECTION FROM THE CEILING. (IRC) PARTITION OR VANITIES AND MAINTAIN 30" MINIMUM CENTER -TO -CENTER BETWEEN 5. WATER HEATING - TANKLESS HOT WATER SYSTEM WITH BUILT-IN RE -CIRCULATION PUMP. 21. CEILINGS IN BASEMENTS WITHOUT HABITABLE SPACES MAY PROJECT TO WITHIN 6 FEET, 8 ADJACENT FIXTURES. 0.97 EF. INCHES OF THE FINISHED FLOOR; AND BEAMS, GIRDERS, DUCTS OR OTHER OBSTRUCTIONS 5. MAINTAIN 21" MINIMUM CLEARANCES IN FRONT OF WATER CLOSETS AND LAVATORIES. 6. PROGRAMMABLE THERMOSTAT STANDARD - ONE PER HEATING/COOLING SYSTEM. MAY PROJECT TO WITHING 6 FEET, 4 INCHES OF THE FINISHED FLOOR. (IRC) 7. DUCT SEALING - LESS THAN OR EQUAL TO 4 CFM/100 SF FOR 2 RETURNS & 6CFM FOR 3 22. SHOWER AND TUB/SHOWER WALLS SHALL BE INSTALLED WITH BACKING PER BUILDER RADON MITIGATION NOTES RETURNS SPECIFICATION & FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT OF 6'-0" (IRC) 1 . 3" MIN. VERTICAL VENT PIPE CONNECTED TO 3" MIN. UNDER SLAB PERFORATED PIPE IN 4" 8. PER SECTION N1 101.14 (R401.3) (MANDATORY) A PERMANENT CERTIFICATE SHALL BE 23. VENT ALL EXHAUST FANS TO EXTERIOR. PROVIDE RAIN CAPS AND FLASHING AS REQUIRED. MIN. GRAVEL BED (BY OTHERS) AND RUN THROUGH HOUSE'S CONDITION SPACE AND ROOF COMPLETED BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL AND POSTED ON A 24. PROVIDE MECHANICAL VENTILATION PER CODE IN BATHROOMS CONTAINING A BATHTUB & FLASH ALL PENETRATIONS. INSTALL PER EPA'S GUIDANCE DOCUMENT FOR RADON OR PER WALL IN THE SPACE WHERE THE FURNACE IS LOCATED A UTILITY ROOM OR AN APPROVED ' AND/OR SHOWER, WATER CLOSET COMPARTMENTS AND SIMILAR ROOMS BUILDER'S GUIDE TO COLD CLIMATES. - AT SLAB ON GRADE LOCATION INSIDE THE BUILDING. THAT DO NOT HAVE ACCESS TO NATURAL VENTILATION. 2 3" MIN. VERTICAL VENT PIPE CONNECTED TO 3" MIN. UNDER SLAB BETWEEN VOID MATERIAL 9. THE AREA -WEIGHTED AVERAGE MAXIMUM FENESTRATION U -FACTOR PERMITTED USING 25. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF AND RUN THROUGH HOUSE'S CONDITION SPACE AND ROOF & FLASH ALL PENETRATIONS. TRADE-OFFS FROM SECTION N1 102.5 SHALL BE 0.48 IN CLIMATE ZONES 4 TREADS OR FLIGHT WITH FOUR OR MORE RISERS. (IRC) HANDRAIL HEIGHT, MEASURED INSTALL PER EPA'S GUIDANCE DOCUMENT FOR RADON OR PER BUILDER'S GUIDE TO COLD AND 5, AND 0.75 IN CLIMATE ZONES 4 THROUGH 8 FOR SKYLIGHTS. VERTICALLY FROM THE SLIPED PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE CLIMATES. - AT STRUCTURAL SLAB ON VOID 10. DUCTS, AIR HANDLERS AND FILTER BOXES SHALL BE SEALED. OF RAMP SLIPE, SHALL BE NOT LESS THAN 34" AND NOT MORE THAN 38". (IRC) ALL REQUIRED 3. INSTALL 6 -MIL MIN. POLYETHYLENE VAPOR BARRIER OR EQUAL ON TOP OF 4" MIN. GRAVEL 1 1 . PER SECTION N1 104.1, NOT LESS THAN 75% OF THE LAMPS IN PERMANENTLY INSTALLED HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE FLIGHT FROM A POINT BED PRIOR CASTING THE SLAB. LAP BARRIER 12" MIN. &FIT CLOSELY AROUND ANY PIPE LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS OR NOT LESS THAN 75% OF THE DIRECTLY ABOVE THE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE PE OR OTHER PENETRATIONS. 4. SEAL ALL PENETRATIONS IN SLAB WITH POLYURETHANE CAULK OR EQUIVALENT SEALANT PER PERMANENTLY INSTALLED LIGHT FIXTURES SHALL CONTAIN ONLY HIGH -EFFICACY LAMPS. LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN MFR'S SPECS. 12. CLASS 1, II OR III VAPOR RETARDERS ARE REQUIRED ON THE INTERIOR SIDE OF FRAME NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A 5. PROVIDE ELECTRICAL POWER IN THE ATTIC WITHIN & OF THE RADON VENT PIPE. RADON FAN WALLS IN CLIMATE ZONE 5. THE FOLLOWING SHALL BE DEEMED TO MEET THE CLASS SPACE OF NOT LESS THAN 1 1/2" BETWEEN THE WALL AND HTE HANDRAILS. (IRC) THE SPECIFIED: HANDRAIL GRIP SIZE IS REQUIRED TO COMPLY WITH IRC. PER SPECIFICATIONS & INSTALLED PER MFR'S SPECIFICATIONS. 12.1. CLASS III: LATEX OR ENAMEL PAINT, PER IRC 26. PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCATED MORE THAN 30" ABOVE THE INSULATION SCHEDULE 13. ALL CRAWLSPACES, IF APPLICABLE, ARE CONDITIONED. FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDES FOUNDATION WALL - UNFINISHED ................................................ R-5 MIN. RIGID FOAM AT 14. SEE PROVIDED "PROJECTED" COMPLIANCE REPORT FROM ENERGY LOGIC. A FINAL OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW EXTERIOR FACE "CONFIRMED" COMPLIANCE REPORT FROM ENERGY LOGIC SHALL BE PROVIDED PRIOR TO A SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSE 2x4 STUD WALL............................................................................... R-13 MIN. PER CERTIFICATE OF OCCUPANCY. OF THE TREADS. (IRC) BUILDER SPECS 27. OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTAL PATTERNS SPACED 2X6 STUD WALL............................................................................... R-20 MIN. PER AIR SEALING NOTES SUCH THAT A 4" SPHERE CANNOT PASS THROUGH (IRC) BUILDER SPECS 1 . DRYWALL GASKET SYSTEM PER BUILDER SPEC AT ALL TOP PLATES ADJOINING AN ATTIC SPACE 28. IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION, AN ATTIC ACCESS ATTIC............................................................................................... R-50 MIN. PER AND AT ALL SEAMS, GAPS AND CRACKS ON GARAGE SEPARATION WALL, INCLUDING OSB OPENING SHALL BE PROVIDED TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET AND HAVE A BUILDER SPECS JUNCTIONS AT TOP PLATE, BOTTOM PLATE AND CORNERS. VERTICAL HEIGHT OF 30" OR GREATER. THE ROUGH -FRAMED OPENING SHALL NOT BE LESS CANTILEVERED FLOORS................................................................... BLOW FULL W/ 2. FOAM SEALANT AT SILLS, GAPS IN FRAMING, OUTLETS ON EXTERIOR WALLS, PENETRATIONS THAN 22" X 30" AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE INSULATION PER BUILDER INTO ATTIC. 2ND AND 3RD SUBFLOOR RIM (TOP AND BOTTOM) AND AT MAIN FLOOR LOCATION. A 30" MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE SPECS WHERE SILL PLATE MEETS THE CONCRETE FOUNDATION. PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE IMC FOR ACCESS RIM JOISTS....................................................................................... 2" CLOSED CELL 3. ALL WINDOW & DOOR FRAMES WIILL BE SEALED WITH A CONTINUOUS BEAD OF REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTICS. (IRC) SPRAY FOAM W/ R-19 BATT NON -EXPANDING FOAM (DOW GREAT STUFF OR EQUIVALENT). 29. PROVIDE WALL AND ROOF FLASHING AT LOCATIONS PER MANUFACTURER'S SPECIFICS, IRC GARAGE CEILING (OPTIONAL).......................................................... R-36 MIN. PER BUILDER AND LOCAL CODES. INSTALL PER BEST PRACTICES, MANUFACTURER'S GUIDELINES OR PER SPECS BUILDER SPECIFICATIONS. CONSULT BUILDER PRIOR TO INSTALL REGARDING ANY 2x4 GARAGE WALL (OPTIONAL)........................................................ R-13 MIN. PER BUILDER QUESTIONS OR CONFLICTS. SPECS 30. OPENINGS AT ELECTRICAL BOXES AND OTHER SIMILAR BOXES EMPLOYING A FLUSH TYPE 2x6 GARAGE WALL (OPTIONAL)........................................................ R-20 MIN. PER BUILDER COVER OR FACEPLATE SHALL BE MADE SO THAT THERE ARE NO GAPS GREATER THAN 1/81, SPECS AROUND THE EDGE OF THE BOX (REPAIR AS NEEDED) 31. VERIFY ALL LOCATIONS, SPANS AND SPACING OF BEAMS, BEARING WALLS, POINT LOADS, JOISTS, RAFTERS AND TRUSSES WITH STRUCTURAL ENGINEER'S DRAWINGS AND CALCULATIONS. 0 f h rive HOME BUILDERS Homes that do more THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM 40 GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 Nl heal o �Q; ci w BLDG TYPE 5A BLOCK 4, LOTS 1-5 Y2-1 N Y4 -E ° o Iw4 LU J U 0 M v U) LU LU LU U 0 M U) LU LU WEST 43RD CIRCLE WEST 43RD CIRCLE --X \ \ ARCHITECTURAL SITE PLAN 1 if = 30'-0" WEST 43RD PLACE WEST 43RD PLACE 30Vjd 4HEb 1S3M 30Vjd 4HEb 1S3M 30Vjd 4HEb 1S3M 10'-6" 10'-6" – –4 8'-9"- Y4 -W Y1 -I Y1 -I _Y2 -E Y2 -E Y1 -I Y1 -I _Y4 -W_ Y1 -I Y2 -I Y2 -I Y4 -E Y4 -E Y2- BLDG TYPE 4B BLDG TYPE 4B BLDG TYPE 5A 8 BLOCK 6, LOTS 5-8 5 6 t, BLOCK 5, LOTS 5-9 BLOCK 6, LOTS 1-4 � � � 5 L 9 E Z 6 g 9 C5) [D� El BLDG TYPE BLDG TYPE 4B% BLOCK 6, LOTS 9-12 BLOCK 6, LOTS 13- Y4 -EA Y1 -IA 1 -IAS Y2 -EA Y2-EA� Y1 -IA Y1 -IA Y4 -WA u IroN RETS AN WEST 42ND AVENUE R.O.W. VARIES WEST 42ND AVENUE R.O.W. VARIES WEST 43RD PLACE 30V_jd 4HEb 1S3M – T 1 E _Y1 -I_ Y1 -I —Y2 -E BLDG TYPE 4B BLOCK 5, LOTS 1-4 b E Z i 8'-9" 8'-9" 11 16 17 18 10 12 13 14 15 BLDG TYPE 5A BLDG TYPE 4B ° BLOCK 5, LOTS 10-14 I BLOCK 5, LOTS 15-18 Y4 -E Y1-1 Y2-1 Y2-1 Y4 -E I Y2 -E Y1-1 Y1 -I Y2 -W WEST 42ND AVENUE R.O.W. VARIES WEST 42ND AVENUE R.O.W. VARIES W. 42ND AVE. 1 0 Y2 -E Y2 -I M BLDG TYPE 4A BLOCK 1, LOTS 1-4 Y2-1 9 Y4 -W 30V4d 4HEb 1S3M 30V_jd 4HEb 1S3M / V N Y4 W Q� H LU wCOw U) 03: ofO of w W VJ O POINTS REQUIRED YI-I 89 (TOTAL) 43 43 VISITABLE DWELLING UNIT 43 1 43 N 1 HOUR TESTED Y4 -EA 43 - 43 ENlheat O C> 6`eco 263 OR IBC SECTION 0 FEET Y2-1 703.3 EXPOSURE U � C) Y1 -IA N ® LU wCOw BLDG 3 FEET Y2 -IA NOT ALLOWED Of U)a PROJECTIONS 1 HOUR UNDERSIDE BLOCK 5, LOTS 19-24 0 HOURS BLDG TYPE f' 30 �� < 3 FEET BLOCK 4, LOTS 6-1 c�O Y2-1 WALLS c� Y2-1 Y4 -E w Q 0� OILK} UNLIMITED (0 HRS) 3 FEET io o YI-I a° ° rn Y4_W a 0 G3 /Y4 -EA w BLDG TYPE 5A BLOCK 4, LOTS 1-5 Y2-1 N Y4 -E ° o Iw4 LU J U 0 M v U) LU LU LU U 0 M U) LU LU WEST 43RD CIRCLE WEST 43RD CIRCLE --X \ \ ARCHITECTURAL SITE PLAN 1 if = 30'-0" WEST 43RD PLACE WEST 43RD PLACE 30Vjd 4HEb 1S3M 30Vjd 4HEb 1S3M 30Vjd 4HEb 1S3M 10'-6" 10'-6" – –4 8'-9"- Y4 -W Y1 -I Y1 -I _Y2 -E Y2 -E Y1 -I Y1 -I _Y4 -W_ Y1 -I Y2 -I Y2 -I Y4 -E Y4 -E Y2- BLDG TYPE 4B BLDG TYPE 4B BLDG TYPE 5A 8 BLOCK 6, LOTS 5-8 5 6 t, BLOCK 5, LOTS 5-9 BLOCK 6, LOTS 1-4 � � � 5 L 9 E Z 6 g 9 C5) [D� El BLDG TYPE BLDG TYPE 4B% BLOCK 6, LOTS 9-12 BLOCK 6, LOTS 13- Y4 -EA Y1 -IA 1 -IAS Y2 -EA Y2-EA� Y1 -IA Y1 -IA Y4 -WA u IroN RETS AN WEST 42ND AVENUE R.O.W. VARIES WEST 42ND AVENUE R.O.W. VARIES WEST 43RD PLACE 30V_jd 4HEb 1S3M – T 1 E _Y1 -I_ Y1 -I —Y2 -E BLDG TYPE 4B BLOCK 5, LOTS 1-4 b E Z i 8'-9" 8'-9" 11 16 17 18 10 12 13 14 15 BLDG TYPE 5A BLDG TYPE 4B ° BLOCK 5, LOTS 10-14 I BLOCK 5, LOTS 15-18 Y4 -E Y1-1 Y2-1 Y2-1 Y4 -E I Y2 -E Y1-1 Y1 -I Y2 -W WEST 42ND AVENUE R.O.W. VARIES WEST 42ND AVENUE R.O.W. VARIES W. 42ND AVE. 1 0 Y2 -E Y2 -I M BLDG TYPE 4A BLOCK 1, LOTS 1-4 Y2-1 9 Y4 -W 30V4d 4HEb 1S3M 30V_jd 4HEb 1S3M / V N Y4 W Q� H LU wCOw U) 03: ofO of w W VJ O ,moo° S3 RiVA ' W O 11 DnNDAV aNZb 1SDM N SITE PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • DIMENSIONS TAKE PRECEDENCE OVER DRAWING - DO NOT SCALE! • THE ARCHITECTURAL SITE PLAN IS INCLUDED TO GRAPHICALLY INDICATE APPROXIMATE LOCATIONS OF BUILDINGS, PARKING, AND BUILDING NUMBERS ONLY. • REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR LANDSCAPING, SIDEWALKS, MONUMENT, AND FENCE DESIGN. • REFER TO CIVIL ENGINEER'S DRAWINGS FOR HORIZONTAL DIMENSIONAL CONTROLS, GRADING, FINISH FLOOR ELEVATIONS, BUILDING STEPPING, DRAINAGE, UTILITY EASEMENTS, AND ACCESSIBLE ROUTE LOCATIONS AND DETAILS. • REFER TO MEP ENGINEER'S DRAWINGS FOR THE LOCATIONS OF ALL METERS, PANELS, CLEANOUTS, TRANSFORMERS, AND PARKING LOT AND SITE LIGHTING. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • AN ACCESSIBLE ROUTE SHALL BE PROVIDED CONNECTING ACCESSIBLE BUILDINGS AND ACCESSIBLE SITE FACILITIES PER IBC 2018 SECTION 1107.4. • ALL ACCESSIBLE ROUTES MUST COMPLY WITH ICC/ANSI A117.1-2009 CHAPTER 4. • SLOPES GREATER THAN 1:20 ON ANY OF THE ACCESSIBLE ROUTES SHALL REQUIRE HANDRAILS COMPLYING WITH ICC/ANSI A117.1-2009 SECTION 405 & 505 AND NOT EXCEED A SLOPE OF 1:12. ADA / ACCESSIBILITY NOTES 2018 INTERNATIONAL RESIDENTIAL CODE NON -ELEVATOR, MULTI -STORY UNITS ARE EXEMPT FROM FAIR HOUSING ACT REQUIREMENTS. IRC 2018 SECTION R320 - ACCESSIBILITY R320.1 SCOPE. WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS IN A SINGLE STRUCTURE, THE PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL APPLY. • IBC 2018 CHAPTER 11 -ACCESSIBILITY 1107.6.3 GROUP R-3. IN GROUP R-3 OCCUPANCIES WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS INTENDED TO BE OCCUPIED AS A RESIDENCE IN A SINGLE STRUCTURE, EVERY DWELLING UNIT AND SLEEPING UNIT INTENDED TO BE OCCUPIED AS A RESIDENCE SHALL BE A TYPE 'B' DWELLING UNIT. EXCEPTION: THE NUMBER OF TYPE 'B' UNITS IS PERMITTED TO BE REDUCED IN ACCORDANCE WITH SECTION 1107.7. 1107.7.2 MULTISTORY UNITS. A MULTISTORY DWELLING OR SLEEPING UNIT WHICH IS NOT PROVIDED WITH ELEVATOR SERVICE IS NOT REQUIRED TO BE A TYPE 'B' DWELLING UNIT. COLORADO STANDARDS FOR ACCESSIBLE HOUSING CRS 9-5, ARTICLE 5 REQUIREMENT: TOTAL # OF UNITS POINTS REQUIRED YI-I 89 (TOTAL) 43 43 VISITABLE DWELLING UNIT 43 1 43 N 1 HOUR TESTED www.goddensudik.com TOTAL 43 - 43 ENlheat O C> 6`eco 263 OR IBC SECTION 0 FEET Y2-1 703.3 EXPOSURE U � C) v I LU L O ZO wO U OeN rW Z V N ® LU wCOw BLDG 3 FEET TYPE 6C - ELEV 2 NOT ALLOWED Of U)a PROJECTIONS 1 HOUR UNDERSIDE BLOCK 5, LOTS 19-24 0 HOURS 3 FEET NOT ALLOWED < 3 FEET OPENINGS IN c�O 3 FEET WALLS c� Y2-1 NOT ALLOWED Q 0� OILK} UNLIMITED (0 HRS) 3 FEET o YI-I a° I rn Y4_W a SITE PLAN ,moo° S3 RiVA ' W O 11 DnNDAV aNZb 1SDM N SITE PLAN NOTES • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • DIMENSIONS TAKE PRECEDENCE OVER DRAWING - DO NOT SCALE! • THE ARCHITECTURAL SITE PLAN IS INCLUDED TO GRAPHICALLY INDICATE APPROXIMATE LOCATIONS OF BUILDINGS, PARKING, AND BUILDING NUMBERS ONLY. • REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR LANDSCAPING, SIDEWALKS, MONUMENT, AND FENCE DESIGN. • REFER TO CIVIL ENGINEER'S DRAWINGS FOR HORIZONTAL DIMENSIONAL CONTROLS, GRADING, FINISH FLOOR ELEVATIONS, BUILDING STEPPING, DRAINAGE, UTILITY EASEMENTS, AND ACCESSIBLE ROUTE LOCATIONS AND DETAILS. • REFER TO MEP ENGINEER'S DRAWINGS FOR THE LOCATIONS OF ALL METERS, PANELS, CLEANOUTS, TRANSFORMERS, AND PARKING LOT AND SITE LIGHTING. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • AN ACCESSIBLE ROUTE SHALL BE PROVIDED CONNECTING ACCESSIBLE BUILDINGS AND ACCESSIBLE SITE FACILITIES PER IBC 2018 SECTION 1107.4. • ALL ACCESSIBLE ROUTES MUST COMPLY WITH ICC/ANSI A117.1-2009 CHAPTER 4. • SLOPES GREATER THAN 1:20 ON ANY OF THE ACCESSIBLE ROUTES SHALL REQUIRE HANDRAILS COMPLYING WITH ICC/ANSI A117.1-2009 SECTION 405 & 505 AND NOT EXCEED A SLOPE OF 1:12. ADA / ACCESSIBILITY NOTES 2018 INTERNATIONAL RESIDENTIAL CODE NON -ELEVATOR, MULTI -STORY UNITS ARE EXEMPT FROM FAIR HOUSING ACT REQUIREMENTS. IRC 2018 SECTION R320 - ACCESSIBILITY R320.1 SCOPE. WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS IN A SINGLE STRUCTURE, THE PROVISIONS OF CHAPTER 11 OF THE INTERNATIONAL BUILDING CODE FOR GROUP R-3 SHALL APPLY. • IBC 2018 CHAPTER 11 -ACCESSIBILITY 1107.6.3 GROUP R-3. IN GROUP R-3 OCCUPANCIES WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS INTENDED TO BE OCCUPIED AS A RESIDENCE IN A SINGLE STRUCTURE, EVERY DWELLING UNIT AND SLEEPING UNIT INTENDED TO BE OCCUPIED AS A RESIDENCE SHALL BE A TYPE 'B' DWELLING UNIT. EXCEPTION: THE NUMBER OF TYPE 'B' UNITS IS PERMITTED TO BE REDUCED IN ACCORDANCE WITH SECTION 1107.7. 1107.7.2 MULTISTORY UNITS. A MULTISTORY DWELLING OR SLEEPING UNIT WHICH IS NOT PROVIDED WITH ELEVATOR SERVICE IS NOT REQUIRED TO BE A TYPE 'B' DWELLING UNIT. COLORADO STANDARDS FOR ACCESSIBLE HOUSING CRS 9-5, ARTICLE 5 REQUIREMENT: TOTAL # OF UNITS POINTS REQUIRED POINTS PROVIDED 89 (TOTAL) 43 43 ACCESSIBLE UNITS PROVIDED UNIT TYPE # OF UNITS PER CRS 9-5 POINTS/ TOTAL UNIT POINTS PROVIDED VISITABLE DWELLING UNIT 43 1 43 SEE WHAT COULD BE 1 HOUR TESTED www.goddensudik.com TOTAL 43 - 43 UNIT TYPE LEGEND VISITABLE DWELLING UNIT = SPRINKLERED = • REFER TO SITE AND GRADING PLANS FOR LOCATIONS OF ACCESSIBLE UNITS AND ACCESSIBLE ROUTES. • PER CRS 9-5, ARTICLE 5, A "TYPE B VISITABLE GROUND FLOOR" MEANS A MULTIPLE -STORY DWELLING UNIT WITH AN ACCESSIBLE ENTRANCE AND TOILET FACILITY DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF ANSI A117.1-1998, SECTION 1003 (ADDITIONAL FEATURES PROVIDED IN ACCORDANCE WITH TYPE 'C' VISITABLE UNITS PER ICC/ANSI A117.1-2009, SECTION 1005. RE: ACCESSIBLE NOTES AND DETAILS). IRC 2018 TABLE R302.10 EXTERIOR WALL REQUIREMENTS - DWELLINGS WITH FIRE SPRINKLERS EXTERIOR MINIMUM FIRE MINIMUM FIRE ELEMENT RESISTANCE SEPARATION RATING DISTANCE SEE WHAT COULD BE 1 HOUR TESTED www.goddensudik.com 5975 S. Quebec Street ASTM E 119 OR UL Centennial, CO 80111 ENlheat O C> 6`eco 263 OR IBC SECTION 0 FEET WALLS 703.3 EXPOSURE U � C) v I LU L O ZO wO U OeN rW Z V OUTSIDE 0 HOURS 3 FEET ISSUE DATE 10/22/2020 NOT ALLOWED < 2 FEET PROJECTIONS 1 HOUR UNDERSIDE 2 FEET 0 HOURS 3 FEET NOT ALLOWED < 3 FEET OPENINGS IN UNLIMITED (0 HRS) 3 FEET WALLS NOT ALLOWED < 3 FEET PENETRATIONS UNLIMITED (0 HRS) 3 FEET FIRE RATED EAVES/WALLS = PROPERTY LINES = n 0 0 w 0 .T 0 U thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat O C> 6`eco O �..LJ U � C) v I LU L O ZO wO U OeN rW Z V 0I V O LLJ O oe CONSTRUCTION SET ISSUE DATE 10/22/2020 ARCHITECTURAL SITE PLAN G3 ROOF -SOFFIT SYSTEMS GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 BLOCK 3, LOTS 13-15 GENERIC PLOT PLAN ISSUE DATE: 06/23/2020 BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- (REVISION 2:10/13/2020) ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 22.1 FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S ENlheat o ci ROOF -SOFFIT SYSTEMS GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 BLOCK 3, LOTS 13-15 GENERIC PLOT PLAN ISSUE DATE: 06/23/2020 BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- (REVISION 2:10/13/2020) ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 22.1 FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S ENlheat o ci cc• c.. oilRDLEVEL /4 -1-0 P2 -E LOT 15 *SPRINKLERED* P1-1 LOT 14 *SPRINKLERED* P3 -E LOT 13 ROOF -SOFFIT SYSTEMS No GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 20'-0" 16-6" 20'-0" BLOCK 3, LOTS 13-15 GENERIC 19'-10" 16-2" 2" 2" 19'-10" (REVISION 2:10/13/2020) ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 22.1 FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S OE DWELLING LINE SEPARATION WALL SHALL BE CONTINUOUS FROM FOUNDATION TO THE AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON • GARAGE SLAB = 21.9 EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ hG JOINTS. UNDERSIDE OF THE ROOF SHEATHING, TYP., PER IRC -----a 2018 R302.2.1 CONTINUITY WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS BLOCK 3, APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. IL IIII ,- APPROPRIATE ROOF COVERING. II u W/D CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR 13 TRUSSES. ,- APPROX. CEILING 15 WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; --- `7 00 I O O J 0 O II I --Cfl �0111 3-PLEX-A UPPER LEVEL BUILDING PLAN A1.20 MENEM— III 0111 OI 1 ------- --------- ------- ------- ------- O III Cfl FJIL- c - --------- Fr 00 F o T oilRDLEVEL /4 -1-0 P2 -E LOT 15 *SPRINKLERED* P1-1 LOT 14 *SPRINKLERED* P3 -E LOT 13 ROOF -SOFFIT SYSTEMS No GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 BLOCK 3, LOTS 13-15 GENERIC PLOT PLAN ISSUE DATE: 06/23/2020 BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- (REVISION 2:10/13/2020) ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. • GARAGE SLAB = 22.1 FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S OE DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON • GARAGE SLAB = 21.9 EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ V)V)W V, o z o wO U o = w Oe z (D JOINTS. ry WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS BLOCK 3, APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. ISSUE DATE 10/22/2020 APPROPRIATE ROOF COVERING. LOT CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR 13 TRUSSES. 14 APPROX. CEILING 15 WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 TYPE - O AREA SEPARATION WALLS GA FILE NO. ASW 1004 PROPRIETARY* GYPSUM WALLBOARD, STEEL H STUDS TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD 2 HOUR FIRE 60 TO 64 STC SOUND THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) nu 0 w 0 .Q 0 .o, thrive PLOT PLAN NOTES Homes that do more. BLOCK 3, LOTS 13-15 B U I L D E R S PLOT PLAN ISSUE DATE: 06/23/2020 (REVISION 2:10/13/2020) LOT 13 SEE WHAT COULD BE • TOS = 23.8 • GARAGE SLAB = 22.1 LOWER FINISHED GRADE ALONG HOUSE POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINING OE LOT 14 • TOS = 23.8 • GARAGE SLAB = 21.9 LOT 15 V)V)W V, o z o wO U o = w Oe z (D • TOS = 23.1 ry • GARAGE SLAB = 21.7 BLOCK 3, LOTS 13-15 ISSUE DATE 10/22/2020 BUILDING TYPE 3A LOT ADDRESS 13 7855 WEST 43RD PLACE 14 7863 WEST 43RD PLACE 15 7867 WEST 43RD PLACE GYPSUM WALLBOARD, STEEL H STUDS TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD 2 HOUR FIRE 60 TO 64 STC SOUND THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) nu 0 w 0 .Q 0 .o, thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 OE O q LU U O Q o V)V)W V, o z o wO U o = w Oe z (D Q C) (D O 3� < w O oe -3: ry Q CONSTRUCTION SET ISSUE DATE 10/22/2020 3-PLEX-A UPPER LEVEL BUILDING PLAN A1.20 BLOCK 3, LOTS 13-15 BUILDING TYPE 3A LOT ADDRESS 13 7855 WEST 43RD PLACE 14 7863 WEST 43RD PLACE 15 7867 WEST 43RD PLACE cc• c.. PLOT PLAN NOTES BLOCK 3, LOTS 13-15 PLOT PLAN ISSUE DATE: 06/23/2020 (REVISION 2:10/13/2020) LOT 13 • TOS = 23.8 • GARAGE SLAB = 22.1 LOWER FINISHED GRADE ALONG HOUSE POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINING LOT 14 • TOS = 23.8 • GARAGE SLAB = 21.9 LOT 15 • TOS = 23.1 • GARAGE SLAB = 21.7 ROOF VENTING CALCULATIONS P1-1 TOTAL ROOF AREA = 660 SQ. FT. = 95,040 INz REQUIRED VENTILATION: X/300 = 316 INz NET FREE AREA VENTILATION PROVIDED: AT ROOF: 3 VENTS @ 51 INz = 153 INz (48%) AT EAVE: 17 LINEAR FEET @ 10 INz = 170 INz TOTAL PROVIDED: 323 INz P2 -E TOTAL ROOF AREA = 819 SQ. FT. = 117,936 1 N REQUIRED VENTILATION: X/300 = 393 INz NET FREE AREA VENTILATION PROVIDED: AT ROOF: 3 VENTS @ 51 INz = 153 INz (40%) AT EAVE: 25 LINEAR FEET @ 10 INz = 250 INz TOTAL PROVIDED: 403 INz P3 -E TOTAL ROOF AREA = 882 SQ. FT. = 127,008 1 N REQUIRED VENTILATION: X/300 = 423 INz NET FREE AREA VENTILATION PROVIDED: AT ROOF: 4 VENTS @ 51 INz = 204 INz (48%) AT EAVE: 25 LINEAR FEET @ 10 INz = 250 INz TOTAL PROVIDED: 454 INz P2 -E LOT 15 *SPRINKLERED* ROOF PLA 1/4" = 11-011 P1-1 LOT 14 *SPRINKLERED* P3 -E LOT 13 ROOF -SOFFIT SYSTEMS GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 4-0" 4-0" 4-0" 4-0" 2602 THRIVE HOME GENERIC 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- GoddenjSudik ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. o = FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER Suite 250 ---------------------------------------- — -- — — — -------------- -------- LINE OF STUD — -- -- -- -------------------------------------- — EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ I LINE OF SOFFIT VENTS RE: ROOF JOINTS. BELOW WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS I APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. CALCS, TYP. APPROPRIATE ROOF COVERING. CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR TRUSSES. I APPROX. CEILING WEIGHT: 04/ I FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 I ch ? I t DWELLING UNIT M SEPARATION WALL SHALL _OH' PLAN A1,30 BE CONTINUOUS FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING, TYP., PER IRC r (0 2018 R302.2.1- CONTINUITY O.H. ROOF VENTS, RE: ROOF CALCS I j ASPHALT SHINGLES COORDINATE LOCATION WITH PLACEMENT OF SOLAR PANELS, TYP. RIDGE I I b b) c� 04/RIDGE III I M1 M I 1' 0" E II O.H. I r— El E 10'-0" ---------- ---------- — N N O -------- II --------------------------------J O 2 a . iv O i P2 -E LOT 15 *SPRINKLERED* ROOF PLA 1/4" = 11-011 P1-1 LOT 14 *SPRINKLERED* P3 -E LOT 13 ROOF -SOFFIT SYSTEMS GA FILE NO. RC WOOD TRUSSES, GYPSUM WALLBOARD 1 HOUR FIRE 2602 THRIVE HOME GENERIC 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM BASE LAYER: 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT -- GoddenjSudik ANGLES TO WOOD ROOF TRUSSES 24" O.C. WITH 1 1/4" TYPE W OR S SEE WHAT COULD BE DRYWALL SCREWS AT 24" O.C. www.goddensudik.com FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER Suite 250 BASE APPLIED AT RIGHT ANGLES TO TRUSSES WITH 1 7/8" TYPE W OR S OE C� `eco DRYWALL SCREWS AT 12" O.C. AT JOINTS AND INTERMEDIATE TRUSSES AND 1 1/2" TYPE G DRYWALL SCREWS AT 12" O.C. PLACED 2" BACK ON EITHER SIDE OF END JOINTS. JOINTS OFFSET 24" FROM BASE LAYER -_-_ F_ Ln WJ LU L ! O ZO wO U C) = �W 0e Z V JOINTS. WOOD TRUSSES SUPPORTING 1/2" WOOD STRUCTURAL PANELS CONSTRUCTION APPLIED AT RIGHT ANGLES TO TRUSSES WITH 8D NAILS. ISSUE DATE 10/22/2020 APPROPRIATE ROOF COVERING. CEILING PROVIDES ONE HOUR FIRE RESISTANCE PROTECTION FOR TRUSSES. APPROX. CEILING WEIGHT: 5 PSF FIRE TEST: FM FC 172, 2-25-72; ITS, 8-6-98 TYPE - O ROOF VENTING NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL ROOF NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • VENTILATION REQUIRED: ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED WITH CORROSION -RESISTANT WIRE CLOTH SCREENING OR SIMILAR MATERIAL W/ OPENINGS HAVING A LEAST DIMENSION OF 1/16" MIN. AND 1/4" MAX. PER 2018 IRC SECTION R806.1. • MINIMUM VENT AREA: THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. REDUCTION OF THE MINIMUM NET FREE VENTILATING AREA TO 1/300 IS PERMITTED PROVIDED THAT AT LEAST 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS, PER 2018 IRC SECTION R806.2. • VENT AND INSULATION CLEARANCE: ROOF VENT LOCATIONS TO BE COORDINATED WITH TRUSSES SO AS NOT TO BLOCK THE FREE FLOW OF AIR AND REDUCE THE NET FREE AREA. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AT THE LOCATION OF THE VENT PER 2018 IRC SECTION R806.3. • INSULATION BAFFLES: WHERE SOFFIT VENTS ARE INDICATED, INSTALL INSULATION BAFFLES TO PROVIDE CLEAR AIR SPACE AS REQUIRED. REFER TO DETAILS FOR ADDITIONAL INFORMATION. • LIMIT ROOF VENTS TO NO MORE THAN TWO OPENINGS PER ROOF SHEATHING PANEL WITH NO TWO OPENINGS IN THE SAME PANEL BETWEEN THE SAME TRUSSES. • UNVENTED ATTIC AND UNVENTED ENCLOSED RAFTER ASSEMBLIES PERMITTED PER 2018 IRC SECTION R806.5. AREA INDICATES COMPLIANCE W/ IRC 2012 R302.2.2 EXCEPTION - IN LIEU OF PARAPET WALLS THE ROOF SHEATHING IS NOTED AS BEING FIRE RETARDANT TREATED WOOD FOR A MINIMUM OF 4 FEET FROM THE WHICHPROPERTY LINE FOR PENETRATIONSOF VENTS AND INTAKES ••••••••••••• LINE INDICATES SOFFIT VENTS APPROXIMATE AREA AVAILABLE FOR INSTALLATION OF SOLAR PANELS. LOCATION VARIES PER SITE ORIENTATION. CONTRACTOR TO COORDINATE DETAILS AND L REQUIREMENTS OF INSTALLATION, TYP. AREA SEPARATION WALLS ROOF PLAN NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON PLANS. • ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM FACE OF FRAME TO END OF TRUSS/RAFTER, RE: DETAILS. ALL SOFFITS ARE TO BE FLAT, U.N.O. • ALL TRUSSES TO BE FABRICATED AND DESIGNED UNDER THE SUPERVISION OF A COLORADO LICENSED STRUCTURAL ENGINEER. • ALL OVERFRAMING TO BEAR DIRECTLY ON TRUSSES OR OVER SOLID, IMMEDIATE BLOCKING BETWEEN TRUSSES. PROVIDE CUTOUTS IN AREAS OF OVERFRAMING TO CONNECT ROOF AREAS. • PROVIDE ROOF VENTS AND / OR SOFFIT VENTS TO PROVIDE ATTIC VENTILATION AS REQUIRED PER 2018 IRC SECTION R806. RE: ROOF VENTING NOTES AND CALCULATIONS. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2018 IRC SECTION P2606. WHERE APPLICABLE, PENETRATIONS IN FIRE -RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH THE REQUIREMENTS OF THE IRC. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2018 IRC SECTION P2607. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. • ROOF ASSEMBLIES PER 2018 IRC CHAPTER R901: ROOF ASSEMBLIES SHALL PROVIDE A WEATHER RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER PROTECTION PER 2018 IRC SECTION R903 AND ROOF COVERINGS PER SECTION R905. RE: FLASHING DETAILS FOR ADDITIONAL INFORMATION. • CRICKETS AND SADDLES SHALL BE INSTALLED AT THE REQUIRED LOCATIONS PER 2018 IRC SECTION R903.2.2. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. PROVIDE APPROPRIATE UNDERLAYMENT AS APPLICABLE TO THE CRICKET OR SADDLE SLOPE. • LOW SLOPE ROOFS -ASPHALT SHINGLES: ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF 2:12 OR GREATER. DOUBLE UNDERLAYMENT SHALL BE PROVIDED AT ROOF SLOPES FROM 2:12 TO LESS THAN 4:12, PER 2018 IRC SECTION R905.2.2. • AN ICE BARRIER SHALL BE INSTALLED AT EAVES, EXTENDING FROM THE LOWEST EDGE TO A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL PER 2018 IRC SECTION R905.1.2 OR AS REQUIRED BY LOCAL AMENDMENTS. eszz•».�:�_�1►r_����ayzsE:�1:z.�yx.>tr�•�►rzisr�� SIZE OF GUTTERS, DOWNSPOUTS, AND SCUPPERS PER BUILDER'S SPECIFICATION AND MANUFACTURER'S REQUIREMENTS BASED ON THE RAINFALL RATE AND CALCULATED AREA BEING DRAINED. WHERE APPLICABLE, SECONDARY DRAINS OR SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. GA FILE NO. ASW GYPSUM WALLBOARD, STEEL H STUDS 2 HOUR FIRE 1004 60 TO 64 PROPRIETARY* STC SOUND TWO LAYERS 1" X 24" PROPRIETARY (MOISTURE RESISTANT) TYPE X GYPSUM PANELS INSERTED BETWEEN 2" FLOOR AND CEILING RUNNERS WITH 2" STEEL H STUDS BETWEEN ADJACENT PAIRS OF GYPSUM PANELS. (NLB) A 3/4" MINIMUM AIR SPACE MUST BE MAINTAINED BETWEEN STEEL COMPONENTS AND ADJACENT FRAMING (INDICATED BY DASHED LINES IN SKETCH). SOUND TESTED WITH 2X4 STUD WALL FACED WITH 1/2" REGULAR GYPSUM WALLBOARD EACH SIDE OF SYSTEM AND 3 1/2" GLASS FIBER IN STUD SPACE ON BOTH SIDES. *PROPRIETARY GYPSUM BOARD AMERICAN GYPSUM COMPANY 1" SHAFT LINER DENSHIELD SHAFTLINER 1" SILENT GUARD GYPSUM LINER BOARD THICKNESS: APPROX. WEIGHT: FIRE TEST: SOUND TEST: TYPE -O 3 1/2" (FIRE) 9.5 PSF UL R6937 (R14196), 04NK19014, 10-28-04, UL DESIGN U375 RAL TL05-149, 7-13-05 11 3/4" (SOUND) n 0 0 w 0 .Q 0 0 thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 OE C� `eco O LU U Q o F_ Ln WJ LU L ! O ZO wO U C) = �W 0e Z V C) (D O LTLJ y O oe -3: CONSTRUCTION SET ISSUE DATE 10/22/2020 3-PLEX-A ROOF PLAN A1,30 1X6 OVER' FA: ASPHALT SHIN ROOF GUTTERS. DOWNSPOUTS, PAINT TO MA ADJACENT MATER .M. EXTENDED WINDOW l TO MEET CORNER T TYP @ END ELEVATI o� 4" TRIM AT DO AND WIND( 3RD LE v 2ND PI VINYL WIND( 6" COMPO LAP SIE rn 2ND LE v 1ST PI UTILITIES MET RE: SITE F 8" EXPOSURE VERTI o) COMPOSITE PANEL SIC AL 1ST LE IX8 TRIM BOARD 36" H. METAL RAILING. 'OWDER COATED 3 LAC K DRAIN THROUGH, ;OMPOSITE WOOD DECK, TYP. METAL AWNING. 'OWDER COATED 3 LAC K IX8 CORNER TRIM 30ARD 4DHERED MASONRY 1X6 OVER 1X10 FASCIA ASPHALT SHINGLE 04 ROOFING M GUTTERS AND DOWNSPOUTS, TYP. ATCH 1'-10" HEEL. PAINT TO M ADJACENT MATERIALS 7 2'-0" O.H. 4" TRIM AT DOORS AND WINDOWS TIE BACKS FOR DECK 6" COMPOSITE LAP SIDING 1X8 TRIM BOARD 8" EXPOSURE VERTICAL COMPOSITE PANEL SIDING DRAIN THROUGH, COMPOSITE WOOD DECK, TYP. LIGHT FIXTURE, RE: ELECTRICAL ADDRESS PLAQUE, TYP. FONT AS ART DECO OR SIMILAR � FRONT ELEVATION P2 -E LOT 15 *SPRINKLERED* 0 PRIVACY DOOR BLOCK 3, LOTS 13-15 BUILDING TYPE 3A LOT ADDRESS 13 7855 WEST 43RD PLACE 14 7863 WEST 43RD PLACE 15 7867 WEST 43RD PLACE ri + 1'-2" HEEL. 2'-0" O.H. PLOT PLAN NOTES BLOCK 3, LOTS 13-15 PLOT PLAN ISSUE DATE: 06/23/2020 (REVISION 2:10/13/2020) LOT 13 • TOS = 23.8 • GARAGE SLAB = 22.1 LOWER FINISHED GRADE ALONG HOUSE POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINING LOT 14 • TOS = 23.8 • GARAGE SLAB = 21.9 LOT 15 • TOS = 23.1 • GARAGE SLAB = 21.7 n 1'-10" HEEL. 2'-0" O.H. ELEVATION NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON ELEVATIONS. • REFER TO BUILDING SECTIONS FOR ADDITIONAL WALL CONSTRUCTION, PLATE HEIGHTS, AND NOTES. • REFER TO PLANS AND DETAILS FOR FIRE RATED ASSEMBLY LOCATIONS, PER LOT SPECIFIC CONDITION. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2018 IRC SECTION P2606. WHERE APPLICABLE, PENETRATIONS IN FIRE -RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH THE REQUIREMENTS OF THE IRC. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2018 IRC SECTION P2607. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • EXTERIOR COVERING PER 2018 IRC SECTION R703: EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4. RE: DETAILS FOR ADDITIONAL INFORMATION. • HEIGHT ABOVE FINISHED GRADE (FOUNDATIONS): FOUNDATION WALLS SHALL EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS A MINIMUM OF 4" WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6" ELSEWHERE PER 2018 IRC SECTION R404. • CLEARANCE TO GRADE PER 2018 IRC SECTION R703: UNLESS NOTED OTHERWISE OR WHEN DIRECTED PER MANUFACTURER'S INSTALLATION REQUIREMENTS, EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE A MINIMUM OF 4" FOR BEARING AND ADHERED MASONRY VENEERS AND A MINIMUM OF 6" FOR OTHER WALL CLADDINGS. EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FLATWORK OR ROOF SURFACES A MINIMUM OF 2". • TYPICAL WINDOW HEAD HEIGHT, U.N.O. LOWER LEVEL: 8'-0" MAIN LEVEL: 8'-0" UPPER LEVEL: 8'-0" oou�aoo _ �ou���ou�=o1 L_J=2 ���n 000aoo�0000000000000 tl� 0 �I�❑o ooODo� 000 0�� 0 000 0- E OooOOo OooOOo OOooOOooOCC:='== I IL OoOOoO 0 11 O O �OC�OO�OO�CO�C 0 E_ =oOC__1 C= Li 0 000aoo=) E== I� _ I10��=0�=E O❑DO❑ O❑Do❑ - ❑�C OoOOoO=L__1- O=cl C=E L E o� VE ��0❑0� ❑owl ❑o�l ❑off ❑off Do �� �o� F- E C o �o�O�oO��oC��L_j_j O-11 P1-1 LOT 14 *SPRINKLERED* P3 -E LOT 13 1X4 CORNER TRIM 10" COMPOSITE LAP SIDING 3RD PLATE ADHERED MASONRY 4" COMPOSITE LAP SIDING 1X10 CORNER a, TRIM BOARD 3RD LEVEL n _ ==Tv 2ND PLATE n TIE BACKS FOR DECK VINYL WINDOWS 36" H'METAL RAILING. POWDER COATED BLACK o� METAL AWNI NG. POWDER COATED BLACK 2ND LEVEL n _ v M 1 ST PLATE n 1ST LEVEL n 0 i� 0 0 0 .o, thriveHOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM 40 GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 0E C> 6`eco O W U C) r� V V V ! O ZO wO U 0eN rW Z V C) V O LLJ O oe -3: ry CONSTRUCTION SET ISSUE DATE 10/22/2020 3-PLEX-A BUILDING ELEVATIONS A3.01 1X6 OVER FA ASPHALT SHIP ROO GUTTERS DOWNSPOUTS, PAINT TO ME ADJACENT MATEF 1X10 COF TRIM BC 4" COMPC LAP SI 1X4 BC 3RD LEVEL 2ND PLATE 1X8 TRIM BC METAL AWP POWDER CO) Bl 2ND LEVEL 1ST PLATE ADHERED MASC ,,—& 1ST LEVEL COMPOSITE WOOD P3 -E DECK, TYP. LOT 13 ,, RIGHT ELEVATION 1/4" = 1'-0" 1X6 OVER 1X10 FASCIA ASPHALT SHINGLE ROOFING GUTTERS AND DOWNSPOUTS, TYP. PAINT TO MATCH ADJACENT MATERIALS 3RD PLATE 3RD LEVEL 2ND PLATE 2ND LEVEL 1ST PLATE 1STLEVEL METAL AWNING. POWDER COATED BLACK DRAIN THROUGH, COMPOSITE WOOD DECK, TYP. OVERHEAD GARAGE DOOR XTENDED WINDOW TRIM O MEET CORNER TRIM. YP @ END ELEVATIONS I" TRIM AT DOORS kND WINDOWS /INYL WINDOWS 0" COMPOSITE .AP SIDING X8 TRIM BOARD EXPOSURE VERTICAL ;OMPOSITE PANEL SIDING u 1'-2" HEEL. 2'-0" O.H. BLOCK 3, LOTS 13-15 BUILDING TYPE 3A LOT ADDRESS 13 7855 WEST 43RD PLACE 14 7863 WEST 43RD PLACE 15 7867 WEST 43RD PLACE PLOT PLAN NOTES BLOCK 3, LOTS 13-15 PLOT PLAN ISSUE DATE: 06/23/2020 (REVISION 2: 10/13/2020) LOT 13 • TOS = 23.8 • GARAGE SLAB = 22.1 LOWER FINISHED GRADE ALONG HOUSE POUR 6" CURB ALONG SIDE OF DRIVE TO PROVIDE POSITIVE DRAINING LOT 14 • TOS = 23.8 • GARAGE SLAB = 21.9 LOT 15 • TOS = 23.1 • GARAGE SLAB = 21.7 J II II II lE 0 P3 -E LOT 13 REAR ELEVATION 1/4" = 1'-0" JULIET BALCONY JP1-1 LOT 14 *SPRINKLERED* M 1'-10" HEEL. 2'-0" O.H. 1X8 TRIMOARD P2 -E BETWEE UNITS LOT 15 *SPRINKLERED* ELEVATION NOTES 2018 INTERNATIONAL RESIDENTIAL CODE • REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION NOT SHOWN OR NOTED ON ELEVATIONS. • REFER TO BUILDING SECTIONS FOR ADDITIONAL WALL CONSTRUCTION, PLATE HEIGHTS, AND NOTES. • REFER TO PLANS AND DETAILS FOR FIRE RATED ASSEMBLY LOCATIONS, PER LOT SPECIFIC CONDITION. • THE ANNULAR SPACE BETWEEN PENETRATIONS OF PIPES AND SIMILAR AND ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR, OR CEILING ASSEMBLY SHALL BE SEALED PER 2018 IRC SECTION P2606. WHERE APPLICABLE, PENETRATIONS IN FIRE—RATED ASSEMBLIES SHALL BE SEALED IN ACCORDANCE WITH THE REQUIREMENTS OF THE IRC. • WATERPROOFING OF OPENINGS AT THE ROOF, AROUND VENT PIPES, AND AT EXTERIOR WALLS SHALL BE MADE WATER TIGHT PER 2018 IRC SECTION P2607. • PIPES AND VENTS SHALL BE PAINTED TO MATCH ADJACENT MATERIALS. • SCUPPERS & DOWNSPOUTS ARE TO BE FIELD VERIFIED FOR LOCATION BY BUILDER. DOWNSPOUTS TO HAVE ADJUSTABLE EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM BUILDING OR AS RECOMMENDED BY SOILS REPORT, OR, WHERE APPLICABLE, CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM. REFER TO CIVIL DRAWINGS FOR DETAILS AND LOCATIONS. • EXTERIOR COVERING PER 2018 IRC SECTION R703: EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4. RE: DETAILS FOR ADDITIONAL INFORMATION. • HEIGHT ABOVE FINISHED GRADE (FOUNDATIONS): FOUNDATION WALLS SHALL EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT ALL POINTS A MINIMUM OF 4" WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6" ELSEWHERE PER 2018 IRC SECTION R404. • CLEARANCE TO GRADE PER 2018 IRC SECTION R703: UNLESS NOTED OTHERWISE OR WHEN DIRECTED PER MANUFACTURER'S INSTALLATION REQUIREMENTS, EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE A MINIMUM OF 4" FOR BEARING AND ADHERED MASONRY VENEERS AND A MINIMUM OF 6" FOR OTHER WALL CLADDINGS. EXTERIOR WALL CLADDINGS SHALL BE ELEVATED FROM ADJACENT FLATWORK OR ROOF SURFACES A MINIMUM OF 2". • TYPICAL WINDOW HEAD HEIGHT, U.N.O. LOWER LEVEL: 8'-0" MAIN LEVEL: 8'-0" UPPER LEVEL: 8'-0" 6" COMPOSITE LAP SIDING 1X8 CORNER TRIM BOARD 1X8 TRIM BOARD 8" EXPOSURE VERTICAL COMPOSITE PANEL SIDING P2 a n 0 s2 0 0 0 thrive HOME BUILDERS Homes that do more. THRIVE HOME B U I L D E R S 1875 LAWRENCE STREET SUITE 900 DENVER, COLORADO 80202 PHONE: 303.707.4400 FAX: 303.348.1384 WWW.THRIVEHOMEBUI LDERS.COM 40 GoddenjSudik ARCHITECTS SEE WHAT COULD BE 303.455.4437 www.goddensudik.com 5975 S. Quebec Street Suite 250 Centennial, CO 80111 ENlheat o �Q; C> CD O W U Q o r� V V V ! O ZO wD U W o V 0 (D 0 w 0 ry ry CONSTRUCTION SET ISSUE DATE 10/22/2020 3-PLEX-A BUILDING ELEVATIONS A3.02 City of Wheat Ridge Residential Fire Sprinkler PERMIT - 202000301 PERMIT NO: 202000301 ISSUED: 02/11/2020 JOB ADDRESS: 7867 W 43rd P1 EXPIRES: 02/10/2021 JOB DESCRIPTION: Install new NFPA 13D fire sprinkler system *** CONTACTS *** OWNER (303)431-9450 THD WESTRIDGE LLC SUB (303)389-9910 DWON LEWIS 060106 EXTREME FIRE PROTECTION CO. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2936 / SHARON MANOR / WESTPARK BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,750.00 FEES Total Valuation 0.00 Use Tax 78.75 Permit Fee 109.20 ** TOTAL ** 187.95 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am 1 thorized to include all entities named within this document as parties to the work to be performed at all work to b r ormed is isclosed in this document and/or its' accompanying approved plans and specifications. /-- Zc) .c,) Signature of OWNER or OR (Circle one Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The Jssuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable coc�r any ordinance.or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of AlPlAw— Je/` Tat K ge = COMMUNITY DEVELOPMENT Building & Inspection Services 7500 W. 291 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits@ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit lJ Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Addr s: a L p es 8(n � � Property Owner (please print): 7'/-/j6 V e f%a . E Phone: 17445Z - -7cq-= eles- Property Owner Email: !f' 2 4t C a CA_ � � VC /-4�,ic be,.J L bC,0,S' C0 &4�, Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: �`%�jL•f �3'i �k`�� ��% City, State, Zip: ��.,� Q,2 , 6-71> 66 6,0 Z, Architect/Engineer: 6,4t 'lo/e,ti d i k— ArchItect/Engineer E-mail: Phone: 575--e1437 Contractor Name: �27 i cTJ�i-� City of Wheat Ridge License M d (O Phone: Contractor E-mail Address: 5 H Iq C3 �_ -'' 6e Lc, - alLe_- e ® -YVL For Plan Review Questions & Comments (please print): CONTACT NAME (please print): _Phone: _0_-Z7 CONTACT EMAIL(please print): -re-& VAr- C-D/+ti Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. ❑COMMERCIAL [E tESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Sq. FULF BTUs e p,3 r p ff �. iGi 5P44 n Gallons Amps Squares For Solar: Kw # of Panels Requires structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1; the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACT ) or (AUTHO ED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE-/— 2c(' ZoZC�> i Printed Name: C DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: CONSTRUCTION TYPE: Building Division Valuation: i