HomeMy WebLinkAbout4713 - 4715 Holland StreetELEMENT
J Building Sciences
ASBESTOS INSPECTION REPORT
Stuart Residence
4713, 4715 Holland St.
Wheat Ridge, CO 80033
Report Date: September 7, 2020
Inspection/Testing Date: September 2, 2020
EBS File: 20-0907
Prepared by:
Ryan Crump
Colorado Certified
Asbestos Building Inspector, 25005
I
Limited Scope of Report
The asbestos inspection performed for client was designed to identify suspect asbestos containing building materials in
the affected areas of the above -referenced subject property as they existed at the time of the inspection. The inspection
was limited to those areas that were visually and physically accessible. The inspection was not a risk assessment,
physical inspection of systems, structure, or components of the subject property, as it relates to their serviceability.
The inspection was performed in accordance with the Standards of Practice of the Colorado Regulation 8 Part B in effect
at the time of this Inspection. This inspection is not intended to be technically exhaustive.
The Inspector has prepared this written asbestos Inspection Report for the sole use and benefit of the client. The
asbestos inspection report shall identify, report, and make recommendation for future evaluation. Client agrees to read
the entire asbestos inspection report when received and shall promptly call the inspector with questions or concerns
regarding the report. The use of this report and information contained herein by others, in whole or in part, is not
authorized without the written mutual consent of the client and Element Building Sciences (EBS).
Purpose and Scope
The purpose of this inspection was to conduct a visual asbestos inspection and to collect necessary samples to
determine the presence or absence of asbestos within the subject property in the affected areas only.
The scope of this report included a visual inspection of all affected rooms and/or areas throughout the subject property
for visible suspect ACM (asbestos containing materials). This does not include any materials that were covered or
hidden by walls, structures, carpeting, wood flooring, multiple layers, wallpaper, texturing, etc. However, the Inspector
made every reasonable effort to access and identify all suspect ACM. Bulk asbestos samples were randomly collected
from homogenous areas of suspect ACM by the above-named Inspector, an EPA/State of Colorado Certified Asbestos
Inspector.
Homogenous areas are defined as any area with the same material, texture, and color. If any of these variables differs
between materials or if for any reason the inspector feels the materials might be different in any respect (such as
materials being installed at different times even though they appear similar), separate sets of samples must be taken
from each homogenous area. Representative bulk samples were taken from similar materials, but this does not
guarantee that materials of similar appearance are of the same composition. Even similar materials are subject to
uneven mixing and distribution and random sampling can miss ACM. EBS used reasonable diligence and its professional
judgment consistent with industry standards to identify all suspect ACM.
Performance of this asbestos inspection is intended to reduce, but not eliminate, uncertainty regarding the presence of
ACM relating to the above referenced property. No guarantee: EBS cannot be held accountable for restrictions placed
on us by the client, conditions or information that remained unknown, or areas that were inaccessible at the time of the
inspection.
Bulk Samples were analyzed by Polarized Light Microscopy (PLM) in general compliance with guidelines established by
the US EPA (40 CFR Part 763, Subpart F, Appendix A). Asbestos concentrations were visually estimated and/or point
counted by the laboratory and reported in percent for each layer of the sample.
The assessment was executed in accordance with the authorized scope of work. If the scope of work is changed, the
inspector must be informed, and an addendum made to this report. This report is solely a record of activities,
observations, analytical results, and recommendations performed to date.
Regulatory Review
EPA and the Colorado Department of Public Health and Environment (CDPHE) regulate all building materials that contain
greater than 1% asbestos as determined through PLM Analysis. OSHA regulates all building materials that contain
smaller amounts of asbestos (even trace concentration as determined by PLM analysis).
EPA and CDPHE Regulation No. 8, Part B, requires that suspect ACM in buildings built prior to 1988 be assumed to be
asbestos or an inspection be conducted prior to demolition or remodeling activities that could disturb ACM. However,
with the North American Free Trade Agreement in effect and trade with countries such as Canada, Mexico, and China, it
can never be determined that a material is not asbestos containing (even if it was produced after 1988) unless it is
tested by a state -certified inspector.
The EPA and CDPHE require all friable and non -friable ACMs in the affected area(s) be removed prior to renovation
activities that may disturb the ACM, and all friable ACM must be removed prior to demolition. Removal or management
of regulated ACM is only required if they may be damaged or disturbed during remodeling, demolition, or burning.
In some circumstances, "point count' analysis is required for bulk samples previously analyzed by PLM. Point counting is
a more detailed means of analysis than standard PLM. Federal and State agencies define ACM as materials containing
greater than 1% asbestos. The NESHAP regulation requires that if standard PLM analysis determines that a sample
contains less than 10% asbestos, the material must be considered asbestos containing or be point counted.
Even if the sample is less than 1% by standard PLM, the material either must be assumed to be ACM or point counted.
the point counting analysis is different than the PLM analysis, the point counting results take precedence over the PLM.
If standard PLM analysis determines that a material has no asbestos or that the material contains greater than 10%
asbestos, point counting is not necessary.
Background
The inspector was called to the subject property by Jim Crump from Jim Black Construction after fire and smoke
impacted the entirety of the homes. Mr. Crump requested this asbestos inspection before allowing any work to begin
in the home.
• Drywall w/ Surfacing Material
• Drywall w/ Joint Compound
• Wallpaper w/ Adhesive
• Sheet vinyl Flooring
• Wall Tile w/ Grout
• Blown in Insulation
• Cave Base w/ Adhesive
Sampled Building Materials
Homogeneous Areas
(HA in RED is asbestos containing)
• Homogeneous Area 1: Drywall w/ Popcorn Surfacing Material 1,142 sf
➢
Unit 4715:
Main Level, Living Room—Ceiling
➢
Unit 4715:
Main Level, Kitchen—Ceiling
➢
Unit 4715:
Main Level, Dining Room—Ceiling
➢
Unit 4715:
Upper Level, Northeast Bedroom —Ceiling
➢
Unit 4715:
Upper Level, Northwest Bedroom —Ceiling
➢
Unit 4715:
Upper Level, Hallway—Ceiling
➢
Unit 4715:
Lower Level, Northwest Bedroom—Ceiling
➢
Unit 4715:
Lower Level, Northeast Bedroom—Ceiling
➢
Unit 4715:
Lower Level, Hallway—Ceiling
• Homogeneous Area 2: Drywall w/ Joint Compound N/A
➢ Unit 4715:
Main Level, Living Room — CeilingJoints
➢ Unit 4715:
Main Level, Kitchen —CeilingJoints
➢ Unit 4715:
Main Level, Dining Room — CeilingJoints
➢ Unit 4715:
Upper Level, Northeast Bedroom —Ceiling Joints
➢ Unit 4715:
Upper Level, Northwest Bedroom — CeilingJoints
➢ Unit 4715:
Upper Level, Hallway — CeilingJoints
➢ Unit 4715:
Lower Level, Northwest Bedroom—CeilingJoints
➢ Unit 4715:
Lower Level, Northeast Bedroom — CeilingJoints
➢ Unit 4715:
Lower Level, Hallway — CeilingJoints
In
• Homogeneous Area 3:
Homogeneous Areas
(HA in RED is asbestos containing)
Drywall w/ Popcorn Surfacing Material
➢ Unit4715:
Main Level, Living Room—Walls
➢ Unit4715:
Main Level, Kitchen—Walls
➢ Unit4715:
Main Level, Dining Room—Walls
➢ Unit4715:
Main Level, Laundry Room—Ceiling and Walls
➢ Unit4715:
Upper Level, Northeast Bedroom —Walls
➢ Unit4715:
Upper Level, Northwest Bedroom —Walls
➢ Unit4715:
Upper Level, Hallway—Walls
➢ Unit4715:
Main Level, Stairwell —Walls
• Homogeneous Area 4: Drywall w/ Joint Compound
➢
Unit4715:
Main Level, Living Room —Wall Joints
➢ Unit4715:
Main Level, Kitchen —Wall Joints
➢ Unit4715:
Main Level, Dining Room —Wall Joints
➢ Unit4715:
Main Level, Laundry Room—Ceiling and Wall Joints
➢ Unit4715:
Upper Level, Northeast Bedroom —Wall Joints
➢ Unit4715:
Upper Level, Northwest Bedroom —Wall Joints
➢ Unit4715:
Upper Level, Hallway —Wall Joints
➢ Unit4715:
Main Level, Stairwell —Wall Joints
• Homogeneous Area 5: Drywall w/ Orange Peel Surfacing Material
➢ Unit4715: Upper Level, Bathroom—Ceiling and Walls
• Homogeneous Area 6: Drywall w/ Joint Compound
➢ Unit4715: Upper Level, Bathroom—Ceiling and Wall Joints
• Homogeneous Area 7: Drywall w/ Heavy Orange Peel Surfacing Material
➢ Unit 4715:
Lower Level, Hallway—Walls
➢ Unit 4715:
Lower Level, Bathroom —Walls
➢ Unit 4715:
Lower Level, Northeast Bedroom —Walls
➢ Unit 4715:
Lower Level, Northwest Bedroom —Walls
• Homogeneous Area 8: Drywall w/ Joint Compound
➢ Unit 4715:
Lower Level, Hallway—Wall Joints
➢ Unit 4715:
Lower Level, Bathroom —Wall Joints
➢ Unit 4715:
Lower Level, Northeast Bedroom —Wall Joints
➢ Unit 4715:
Lower Level, Northwest Bedroom —Wall Joints
5
1,332 sf
N/A
200 sf
N/A
654 sf
N/A
Homogeneous Areas
(HA in RED is asbestos containing)
• Homogeneous Area 9: Drywall w/ Joint Compound N/A
➢ Unit 4715: Main Level,Garage —Ceiling and Wa I I Joints
• Homogeneous Area 10: Sheet Vinyl Flooring 105 sf
➢ Unit 4715: Upper Level, Bathroom — Floor
➢ Unit 4715: Lower Level, Bathroom —Floor
• Homogeneous Area 11: Sheet Vinyl Flooring 81 sf
➢ Unit 4715: Main Level, Laundry Room—Floor
• Homogeneous Area 12: Blown in Insulation N/A
➢ Unit 4715: Main Level, Attic—Floor
• Homogeneous Area 13: Wall Tile w/ Grout 45 sf
➢ Unit 4715: Upper Level, Bathroom —Walls
• Homogeneous Area 14: Sheet Vinyl Flooring 160 sf
➢ Unit 4715: Main Level, Kitchen—Floor
• Homogeneous Area 15: Drywall w/ Brush Stomp Surfacing Material 1,127 sf
➢ Unit 4713: Living Room—Walls
➢ Unit 4713: LaundryRoom—CeilingandWalls
➢ Unit 4713: Southwest Bedroom —Walls
➢ Unit 4713: Southeast Bedroom — Walls
➢ Unit 4713: Kitchen — Walls
• Homogeneous Area 16: Drywall w/ Joint Compound N/A
➢ Unit 4713: Living Room —Wall Joints
➢
Unit4713: Laundry Room —Ceilingand Wall Joints
➢ Unit 4713: Southwest Bedroom — Wall Joints
➢ Unit 4713: Southeast Bedroom — Wall Joints
➢ Unit 4713: Kitchen — Wall Joints
• Homogeneous Area 17: Drywall w/ Popcorn Surfacing Material 567 sf
➢ Unit 4713: Living Room—Ceiling
➢ Unit 4713: Kitchen—Ceiling
➢ Unit 4713: Southwest Bedroom —Ceiling
➢ Unit 4713: Southeast Bedroom—Ceiling
6
Homogeneous Areas
(HA in RED is asbestos containing)
• Homogeneous Area 18: Drywall w/ Joint Compound N/A
➢ Unit 4713: Living Room –CeilingJoints
➢ Unit 4713: Kitchen –CeilingJoints
➢ Unit 4713: Southwest Bedroom–CeilingJoints
➢ Unit 4713: Southeast Bedroom–CeilingJoints
• Homogeneous Area 19: Drywall w/ Orange Peel Surfacing Material 353 sf
➢ Unit 4713: Bathroom—Ceiling and Walls
➢ Unit 4713: Kitchen –Walls
• Homogeneous Area 20: Drywall w/ Joint Compound N/A
➢ Unit 4713: Bathroom—Ceiling and Wall Joints
➢ Unit 4713: Kitchen –Wall Joints
• Homogeneous Area 21: Wall Tile w/ Grout N/A
➢ Unit 4713: Kitchen –Walls
• Homogeneous Area 22: Wall Tile w/ Grout N/A
➢ Unit 4713: Bathroom–Walls
• Homogeneous Area 23: Sheet Vinyl Flooring 196 sf
➢ Unit 4713: Kitchen – Floor
➢ Unit 4713: Laundry Room–Floor
• Homogeneous Area 24: Sheet Vinyl Flooring 45 sf
➢ Unit 4713: Bathroom–Floor
• Homogeneous Area 25: Wallpaper w/ Adhesive N/A
➢ Unit 4713: Southwest Bedroom –North Wall
• Homogeneous Area 26: Cove Base w/ Adhesive N/A
➢ Unit 4713: Kitchen –Walls
➢ Unit 4713: Laundry Room –Walls
Sampling
The Inspector determined that it was necessary to collect 65 bulk samples from the various homogenous areas (see
the Asbestos Sampling below for exact areas). All samples were submitted to an accredited third -party independent
laboratory. The laboratory results are attached to and incorporated into this report.
7
Testing Locations
(Samples in RED are asbestos containing)
SM = Surfacing Material SD = Significantly Damaged ND = None Detected
TSI = Thermal Systems Insulation D = Damaged
MM = Miscellaneous Material G = Good
Material
Sample
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4715:
Main Level,
1C
Living Room —
Ceiling
Unit 4715:
Main Level,
2C
Kitchen —
Ceiling
Unit 4715:
3C
Upper Level,
D wallw/
ry
Gray
Hallway—
Compound
1
SM
Popcorn
Yes
Damaged
Ceiling
g
3/
Texture
Chrysotile
Unit 4715:
Upper Level,
4C
Northeast
Bedroom —
Ceiling
Unit 4715:
Lower Level,
5C
Northeast
Bedroom —
Ceiling
Off White
Unit 4715:
Joint
Upper Level,
Compound3
6JC
Northwest
%Chrysotile
Bedroom —
White
Ceiling Joint
Drywall w/ Joint
Foamy
2
MM
Yes
Damaged
Compound
Texture w/
Unit 4715:
White/black
Lower Level,
charred
7JC
Northwest
paint
Bedroom —
8
Ceiling Joint
Chrysotile
SM = Surfacing Material SD = Significantly Damaged ND = None Detected
TSI = Thermal Systems Insulation D = Damaged
MM = Miscellaneous Material G = Good
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4715:
Main Level,
BW
Living Room —
West Wall
Unit 4715:
Main Level,
9W
Kitchen —
North Wall
Unit 4715:
Upper Level,
Drywall w/
White
3
10W
Northwest
SM
Brush Stomp
Yes
Damaged
Compound
Bedroom —
4%
North Wall
Texture
Chrysotile
Unit 4715:
Upper Level,
11W
Northeast
Bedroom —
East Wall
Unit 4715:
Main Level,
12W
Laundry Room —
South Wall
Unit 4715:
Main Level,
13JC
Living Room —
Gray
North Wall Joint
Drywall w/ Joint
Compound
4
MM
Yes
Damaged
Unit 4715:
Compound
3%
Main Level,
Chrysotile
141C
Stairwell —
East Wall Joint
Unit 4715:
Upper Level,
15C
White
Bathroom —
C
Ceiling
Compound
Unit 4715:
Drywall w/
Chryso
Chrysotile
s
l
Upper Level,
5
16W
SM
Orange Peel
Yes
Damaged
Bathroom
Texture
White Joint
West Wall
Compound
Unit 4715:
3%
17W
Upper Level,
Chrysotile
Bathroom —
East Wall
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
1k
(TSI,SM,MM)
Content
a
Unit 4715:
White
Upper Level,
Compound
181C
Bathroom —
3%
North Wall Joint
Chrysotile
Drywall w/ Joint
6
MM
Yes
Damaged
Unit 4715:
Compound
White Joint
19JC
Upper Level,
Compound
Bathroom —
Ceiling Joint
Chrysotile
Unit 4715:
Lower Level,
20W
Northeast
Bedroom —
East Wall
Unit 4715:
Drywall w/
White
7
Lower Level,
SM
Orange Peel
Yes
Damaged
Compound
21W
Northwest
3%
Bedroom —
Texture
Chrysotile
West Wall
Unit 4715:
Lower Level,
22W
Hallway—
South Wall
Pink
Unit 4715:
Compound
Lower Level,
3%
23JC
Bathroom —
Chrysotile
East Wall Joint
White
Drywall w/ Joint
Compound
8
MM
Yes
Damaged
Compound
3%
Unit 4715:
Chrysotile
Lower Level,
White Joint
241C
Stairwell —
Compound
West Wall Joint
3%
Chrysotile
Off White
Compound
25JC
3%
Unit 4715:
Main Level,
Drywall w/ Joint
Chrysotile
9
MM
Yes
Damaged
Off White
Garage—
Compound
Joint
26JC
West Wall Joints
Compound
3%
Chrysotile
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
10
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4715:
Upper Level,
27F
Bathroom —
Gra y
Floor
Sheet Vinyl
Fibrous
10
MM
Yes
Damaged
Material
Unit 4715:
Flooring
o
60/
28F
Lower Level,
Chrysotile
Bathroom —
B
Floor
29F
Unit 4715:
Main Level,
Sheet Vinyl
11
MM
Yes
Damaged
ND
Laundry Room —
Flooring
30F
Floor
311
Unit 4715:
Main Level,
12
MM
Blown in Insulation
Yes
Damaged
ND
Attic —
321
Floor
33WT
Unit 4715:
13
Upper Level,
MM
WallTilew/Grout
No
Damaged
ND
Bathroom —
3gWT
West Wall
35F
Unit 4715:
Main Level,
Sheet Vinyl
14
MM
Yes
Damaged
ND
Kitchen—
Flooring
36F
Floor
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
11
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4713:
37W
Living Room —
West Wall
Unit 4713:
Southwest
38W
Bedroom —
North Wall
Drywall w/
Off White
Unit 4713:
Compound
15
Southeast
SM
Brush Stomp
Yes
Damaged
39W
Bedroom —
Texture
3%
Chrysotile
West Wall
Unit 4713:
40W
Laundry Room —
North Wall
Unit 4713:
41C
Laundry Room —
Ceiling
Unit 4713:
42JC
Living Room —
Off White
North Wall Joint
Drywall w/ Joint
Compound
16
MM
Yes
Damaged
Unit 4713:
Compound
3%
43JC
Laundry Room—
Chrysotile
North Wall Joint
Unit 4713:
Southwest
44C
Bedroom —
Ceiling
White
Unit 4713:
Drywall w/
Foamy
17
45C
Southeast
SM
Popcorn
Yes
Damaged
Texture w/
Bedroom —
Texture
white Paint
Ceiling
7%
Chrysotile
Unit 4713:
46C
Living Room —
Ceiling
Off White
Unit 4713:
Compound
47JC
Living Room —
3%
Ceiling Joint
Chrysotile
Drywall w/ Joint
18
MM
Yes
Damaged
Tan Foamy
Compound
Texture w/
Unit 4713:
48JC
Kitchen—
white paint
Ceiling Joint
7%
Chrysotile
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
12
Testing Locations
(Samples in RED are asbestos containing)
13
Material
Sample
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4713:
49W
Bathroom — North
Wall
Drywall w/
Off White
Unit 4713: Kitchen
19
SOW
—
SM
Orange Peel
Yes
Damaged
Compound
North Wall
Texture
3/
Chrysotile
Unit 4713:
51W
Kitchen—
West Wall
Off White
Unit 4713:
Compound
52JC
Bathroom — North
3%
Wall Joint
Chrysotile
wall w/
Dryompound Joint
20
MM
Yes
Damaged
Off White
Compound
Unit 4713: Kitchen
Joint
53JC
—
Compound
South Wall Joint
3%
Chrysotile
54WT
Unit 4713: Kitchen
21
—
MM
WaIlTilew/Grout
No
Damaged
ND
South Wall
SSWT
56WT
Unit 4713:
22
Bathroom—South
MM
WaIlTilew/Grout
No
Damaged
ND
Wall
57WT
Unit 4713:
58F
Laundry Room —
Floor
23
MM
Sheet Vinyl Flooring
Yes
Damaged
ND
Unit 4713: Kitchen
59F
—
Floor
Tan/multi-
colored
60F
Sheet Vinyl
w/ Off
Unit 4713:
White
24
Bathroom —
MM
Sheet Vinyl Flooring
Yes
Damaged
Fibrous
Floor
Backing
61F
Material
15%
Chrysotile
13
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
62WP
Unit 4713:
Off White
Southwest
Wallpaper w/
Compound
25
Bedroom—
MM
Adhesive
yes
Damaged
3%
63WP
North Wall
Chrysotile
64CB
Unit 4713:
Cave Base w/
26
LaundryRoom—
MM
No
Damaged
ND
Adhesive
South Wall
65CB
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
14
Conclusion
Asbestos containing building materials WERE found in the samples analyzed by the laboratory. The affected building materials DO
need to be removed by a certified abatement company according to Regulation 8 of CDPHE. Caution should always be taken and
OSHA personal protective equipment should be used during any removal of sampled building materials.
Based on said analysis, ELEMENT Building Sciences has determined that approximately 265 square feet of asbestos containing
material has been disturbed in the kitchen and living room and possibly become airborne. According to CDPHE Regulation 8, the
amount of asbestos containing material disturbed has resulted in a MAJOR SPILL. It is the recommendation of ELEMENT Building
Sciences that this disturbance be reported to the Colorado Department of Public Health and Environment and the Colorado Air
Pollution Control Division (per CDPHE Reg 8 Sec III.T.1.c) as soon as possible.
CDPHE Colorado Environment Release and Incident Reporting Line (24-hour)
- +1 (877) 518-5608
- cdphe.asbestos(@state.co.us
Colorado Air Pollution Control Division
- +1 (303) 692-3100
- cd phe.commentsapcdPstate.co.us
For more information on possible spill response, please see CDPHE Regulation 8:
https://www.colorado.gov/pacific/sites/default/files/AP ASB Regulation -No -8 -Part -B -Asbestos -amended -December -21 -2007 -
effective -1 a n ua ry-30-2008. pdf
ELEMENT assumes no liability for any loss, injury, claim or damages arising directly or indirectly from any use or reliance on this rep
ort or the opinions expressed herein. ELEMENT makes no risk assessment, warranty
guarantee or insurance policies of any kind express or implied. This report is limited only to the samples taken
and locations sampled. There are no risk assessments, warranties, guarantees, or insurance available or provided by ELEMENT.
Additional sampling may be needed to further identify other pollutants, or other mold/fungus affected areas inside the subject prop
e rty.
This report was prepared pursuant to the contract ELEMENT has with the client. That contractual relationship
included an exchange of information about the subject property that was unique and between ELEMENT and its
client and serves as the basis upon which this report was prepared. Because of the importance of the
communication between ELEMENT and its client, reliance or any use of this report by anyone other than the client, for
whom it was prepared, is prohibited and therefore not foreseeable to ELEMENT.
15
c ' W+E
61 S
w
N
W+E
s
9
n
E
J
E
°o
11
e
E
E
A�
F1
E
91
Overview of Unit 4715
Overview of Unit 4715: Main Level, Living Room
Overview of Unit 4715: Main Level, Kitchen
Overview of Unit 4715: Main Level, Dining Room
Overview of Unit 4715: Laundry Room
19
Overview of Unit 4715: Garage
Overview of Unit 4715: Upper Level, Northeast Bedroom
Overview of Unit 4715: Upper Level, Bathroom
Overview of Unit 4715: Upper Level, Northwest Bedroom
Overview of Unit 4715: Stairwell to Lower Level
Overview of Unit 4715: Lower _vel, Bathroom
G.=rview of Unit 4715: Lower Level, Northwest Bedroom
20
Overview of Unit 4715: Lower Level, Northeast Bedroom
Overview of Unit 4713
Overview of Unit 4713: Living Room
Overview of Unit 4713: Kitchen
21
Overview of Unit 4713: Laundry Room
Overview of Unit 4713: Bathroom
Overview of Unit 4713: Southwest Bedroom
Overview of Unit 4713: Southeast Bedroom
22
September N, 9020
Pr
REAS recent
yiort
,�.o s
201
FrtRul UeaanpYm:
Sol
REI LASS
Water—
Reservoirs
Environmental,
Inc.
September N, 9020
Pr
REAS recent
yiort
,�.o s
201
FrtRul UeaanpYm:
Sol
Ryan fimmp
Sciences
BBN WOIfl Ct
side 140
abnormal r CO 8OD31
bear Main
Reemoo-e Environmental Inc is an analytical phoaron the edlled for the analysis M IndWFW Happen and
Emlronmemal m ces by the National voluntary Laboratory A:aetlpa4on Program (it"LAP), Lab Cape
1010930 for Transmission ElHron Microscopy (i and Polarized Light Mlcrampy(PLM] anodes, and Me
Amerlian In ouNal Myglme Assn on (/JXAJ. Lab 10 lC16A - paymen Om CeNOpu= NW !a Please
Contrast Mlvosccpy 1POMt analysts This tarred is currently pmficlern In ash Pmfidenry Testing and PAT
Programs t�PemmeN
Missouri Environmental Inc. las anayieb the rollwnne samples for asbestos content as per your requeden
neNets has Isperin composed In repeal accordance with Me appropriate migratio9y as araletl In Ne
atl ed analysis bible. The not have been submkedbyour office.
RES am W-0 is the job number awgretl to this sway. This open is¢neiderea highly centro lal and Me
orp, pmRerly or any pan of gr dy w�
other those entry cfcrM1 The results reacnsanln thee departure apply to the ampler analysed
Personal ryytgP or any agenryol
This et be Me neypod shat not be a(petluer except
in
ill yo by
Me US repan N ry repmdumn event M n M equl !m
N14 `^'hoN wipe
r@servrvrs Environmerol, Inc this rep rill be dcsycs fr e c callsistytlrys unless longvsbagae rryuesred
If you Fere airyquesllms adaN this report pleax bel tree N a113g396f-1986.
RESERVOIRS ENVIRONMENTAL ING
2C NSA "i pAr Sub, Bull
3c N,`n.bAAd,kC1SWJk1
4, NSA All BE Seem bubble,
11 Kbinkeedpilluel
11 bublukeekeepull
TABLE ELSE BULK fidell All Ell COMl
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
01.1
SEES Being SumenceS
bee Plujukulki `0
I'll,
„a,.a.,o.�,
Turmrmn±
Pi
111 A 1
2C NSA "i pAr Sub, Bull
3c N,`n.bAAd,kC1SWJk1
4, NSA All BE Seem bubble,
11 Kbinkeedpilluel
11 bublukeekeepull
TABLE ELSE BULK fidell All Ell COMl
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
TABLE ELSE BULK fidell All Ell COMl
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
to I T A An All Ole
III Il
ullon,
Element ill All
Client
L
Ill
Joe, examop .. Rece.
I.Aboomber 1, MI
Joint
Pool
Date Some es Annobed
Ni
to I T A An All Ole
Fee Job No An
III Il
CIA,
Ekentrentill.demikerente
Client
L
Ill
Joe, examop .. Rece.
I.Aboomber 1, MI
Joint
Pool
Date Some es Annobed
Ni
I been, Pat
Motenj vel
Diet.
Di
10
E A� Abele .11AI 75
ND
DO
10.0
No Mal,i er Centel
2"
DAMCDAWAirCIDIFFICA.
Fee Job No An
III Il
CIA,
Ekentrentill.demikerente
01 .1 Peel beenteneen
Ill
Joe, examop .. Rece.
I.Aboomber 1, MI
Joint
Pool
Date Some es Annobed
I.."r 1. JU21
a
Di
RESERVOIRS ENVIRONMENTAL INC
III
I
Ageteency.
beer
be,
Ment
grand,
I1AddGyd3dNI ll "I
Carl
MA 9 Grateeld. Gray depead...
RESERVOIRS ENVIRONMENTAL INC
III
I
Ageteency.
beer
be,
Ment
grand,
I1AddGyd3dNI ll "I
"I any",
I Off 11 Fail 1
11
1
IN
I Gray I by buyer al P rear al 1 11
11
In
r
H A cranially CIS NO real MWW 11
11
1
INC
ISF
red ben Gerald be (Sugar Ruder
RESERVOIRS ENVIRONMENTAL INC
CI da Pr lad Day nual
Ment
grand,
I1AddGyd3dNI ll "I
"I any",
I Off 11 Fail 1
11
1
IN
I Gray I by buyer al P rear al 1 11
11
In
r
H A cranially CIS NO real MWW 11
11
1
INC
D
11.1
Ell Bk1dEg4l
all,
L
01.1 PulEl
11.1
D
all,
L
01.1 PulEl
11.1
41,
A fil' hum cumuli. 1
17
D
01.1 PulEl
11.1
D
41,
A fil' hum cumuli. 1
17
a., EBKUKABWdflL2Kexes
�ww
F K
VILId
,. ,.m.ImL ,..
;
a., EBKUKABWdflL2Kexes
RESERVI ENVIRONMENTAL INC
1I I bol. OR
SRI do
ISI
®.
oRpooffoRr M, MD
OF
1I I bol. OR
SRI do
ISI
RISPISS
OF
III ASSISSed por Clow DID
1I I bol. OR
T@eservairs Envimnmen[ai, Inc. RES Joc x anzaz_
,
_ ...
..
AL 31
._
....,f
t
kim
s KU31 kN ..........1
m_
{
.:.
i�
:.
M
li. ink
�I
i° esti il�sisii
�FIR
ass
4iI�li9iIiial
i�iI
i
��
his ai83P8�Ra IiI
�a
i�1
i t
J
iii ii J
J
L I....IJ
.... ....
...
�
iit rr —ii
t
Yrs �
I
III II "II
I
FI"'I]
22 T
1
"kin
:1
11t 11 -11
i
:t i t 1
Z
,
_ ...
..
Element Building Sciences (EBS) assumes no liability for any loss, injury, claim or damages arising directly or indirectly
from any use or reliance on this report or the opinions expressed herein. EBS makes no risk assessment, warranty,
guarantee or insurance policies of any kind, express or implied. This report is limited only to the samples taken and
locations sampled. There are no risk assessments, warranties, guarantees, or insurance available or provided by EBS.
Additional sampling may be needed to further identify other pollutants, or other mold/fungus affected areas inside the
subject property.
This report was prepared pursuant to the contract EBS has with the client. That contractual relationship included an
exchange of information about the subject property that was unique and between EBS and its client and serves as the
basis upon which this report was prepared. Because of the importance of the communication between EBS and its client,
reliance, or any use of this report by anyone other than the client, for whom it was prepared, is prohibited and therefore
not foreseeable to EBS. No warranty is made. EBS liability and that of contractors and subcontractors arising from any
service rendered hereunder shall not exceed the total fee paid by the client to EBS.
Thank you for the opportunity to work with you on this project. Please call at 720.537.0963 with any questions or
concerns. Thank you.
Sincerely,
Ryan Crump
Element Building Sciences
Colorado State Certified
Asbestos Inspector, 25005
33
g€..5.a
ASBESTOS CONSLITUBd FHOI
C ons B.WkeegS. ....CgLLC
Vm:.^ .?Pw ..... ..
weso® j
ASRESfUS
C TMCITION-
W
utdoomp
...ru �.x�u.n..,m.. ._ �m
.
G�rm dew
edrd
Pu�xng �^aPM.f� S .
_, ...s.n=um
ELEMENT
J Building Sciences
ASBESTOS INSPECTION REPORT
Stuart Residence
4713, 4715 Holland St.
Wheat Ridge, CO 80033
Report Date: September 7, 2020
Inspection/Testing Date: September 2, 2020
EBS File: 20-0907
Prepared by:
Ryan Crump
Colorado Certified
Asbestos Building Inspector, 25005
I
Limited Scope of Report
The asbestos inspection performed for client was designed to identify suspect asbestos containing building materials in
the affected areas of the above -referenced subject property as they existed at the time of the inspection. The inspection
was limited to those areas that were visually and physically accessible. The inspection was not a risk assessment,
physical inspection of systems, structure, or components of the subject property, as it relates to their serviceability.
The inspection was performed in accordance with the Standards of Practice of the Colorado Regulation 8 Part B in effect
at the time of this Inspection. This inspection is not intended to be technically exhaustive.
The Inspector has prepared this written asbestos Inspection Report for the sole use and benefit of the client. The
asbestos inspection report shall identify, report, and make recommendation for future evaluation. Client agrees to read
the entire asbestos inspection report when received and shall promptly call the inspector with questions or concerns
regarding the report. The use of this report and information contained herein by others, in whole or in part, is not
authorized without the written mutual consent of the client and Element Building Sciences (EBS).
Purpose and Scope
The purpose of this inspection was to conduct a visual asbestos inspection and to collect necessary samples to
determine the presence or absence of asbestos within the subject property in the affected areas only.
The scope of this report included a visual inspection of all affected rooms and/or areas throughout the subject property
for visible suspect ACM (asbestos containing materials). This does not include any materials that were covered or
hidden by walls, structures, carpeting, wood flooring, multiple layers, wallpaper, texturing, etc. However, the Inspector
made every reasonable effort to access and identify all suspect ACM. Bulk asbestos samples were randomly collected
from homogenous areas of suspect ACM by the above-named Inspector, an EPA/State of Colorado Certified Asbestos
Inspector.
Homogenous areas are defined as any area with the same material, texture, and color. If any of these variables differs
between materials or if for any reason the inspector feels the materials might be different in any respect (such as
materials being installed at different times even though they appear similar), separate sets of samples must be taken
from each homogenous area. Representative bulk samples were taken from similar materials, but this does not
guarantee that materials of similar appearance are of the same composition. Even similar materials are subject to
uneven mixing and distribution and random sampling can miss ACM. EBS used reasonable diligence and its professional
judgment consistent with industry standards to identify all suspect ACM.
Performance of this asbestos inspection is intended to reduce, but not eliminate, uncertainty regarding the presence of
ACM relating to the above referenced property. No guarantee: EBS cannot be held accountable for restrictions placed
on us by the client, conditions or information that remained unknown, or areas that were inaccessible at the time of the
inspection.
Bulk Samples were analyzed by Polarized Light Microscopy (PLM) in general compliance with guidelines established by
the US EPA (40 CFR Part 763, Subpart F, Appendix A). Asbestos concentrations were visually estimated and/or point
counted by the laboratory and reported in percent for each layer of the sample.
The assessment was executed in accordance with the authorized scope of work. If the scope of work is changed, the
inspector must be informed, and an addendum made to this report. This report is solely a record of activities,
observations, analytical results, and recommendations performed to date.
Regulatory Review
EPA and the Colorado Department of Public Health and Environment (CDPHE) regulate all building materials that contain
greater than 1% asbestos as determined through PLM Analysis. OSHA regulates all building materials that contain
smaller amounts of asbestos (even trace concentration as determined by PLM analysis).
EPA and CDPHE Regulation No. 8, Part B, requires that suspect ACM in buildings built prior to 1988 be assumed to be
asbestos or an inspection be conducted prior to demolition or remodeling activities that could disturb ACM. However,
with the North American Free Trade Agreement in effect and trade with countries such as Canada, Mexico, and China, it
can never be determined that a material is not asbestos containing (even if it was produced after 1988) unless it is
tested by a state -certified inspector.
The EPA and CDPHE require all friable and non -friable ACMs in the affected area(s) be removed prior to renovation
activities that may disturb the ACM, and all friable ACM must be removed prior to demolition. Removal or management
of regulated ACM is only required if they may be damaged or disturbed during remodeling, demolition, or burning.
In some circumstances, "point count' analysis is required for bulk samples previously analyzed by PLM. Point counting is
a more detailed means of analysis than standard PLM. Federal and State agencies define ACM as materials containing
greater than 1% asbestos. The NESHAP regulation requires that if standard PLM analysis determines that a sample
contains less than 10% asbestos, the material must be considered asbestos containing or be point counted.
Even if the sample is less than 1% by standard PLM, the material either must be assumed to be ACM or point counted.
the point counting analysis is different than the PLM analysis, the point counting results take precedence over the PLM.
If standard PLM analysis determines that a material has no asbestos or that the material contains greater than 10%
asbestos, point counting is not necessary.
Background
The inspector was called to the subject property by Jim Crump from Jim Black Construction after fire and smoke
impacted the entirety of the homes. Mr. Crump requested this asbestos inspection before allowing any work to begin
in the home.
• Drywall w/ Surfacing Material
• Drywall w/ Joint Compound
• Wallpaper w/ Adhesive
• Sheet vinyl Flooring
• Wall Tile w/ Grout
• Blown in Insulation
• Cave Base w/ Adhesive
Sampled Building Materials
Homogeneous Areas
(HA in RED is asbestos containing)
• Homogeneous Area 1: Drywall w/ Popcorn Surfacing Material 1,142 sf
➢
Unit 4715:
Main Level, Living Room—Ceiling
➢
Unit 4715:
Main Level, Kitchen—Ceiling
➢
Unit 4715:
Main Level, Dining Room—Ceiling
➢
Unit 4715:
Upper Level, Northeast Bedroom —Ceiling
➢
Unit 4715:
Upper Level, Northwest Bedroom —Ceiling
➢
Unit 4715:
Upper Level, Hallway—Ceiling
➢
Unit 4715:
Lower Level, Northwest Bedroom—Ceiling
➢
Unit 4715:
Lower Level, Northeast Bedroom—Ceiling
➢
Unit 4715:
Lower Level, Hallway—Ceiling
• Homogeneous Area 2: Drywall w/ Joint Compound N/A
➢ Unit 4715:
Main Level, Living Room — CeilingJoints
➢ Unit 4715:
Main Level, Kitchen —CeilingJoints
➢ Unit 4715:
Main Level, Dining Room — CeilingJoints
➢ Unit 4715:
Upper Level, Northeast Bedroom —Ceiling Joints
➢ Unit 4715:
Upper Level, Northwest Bedroom — CeilingJoints
➢ Unit 4715:
Upper Level, Hallway — CeilingJoints
➢ Unit 4715:
Lower Level, Northwest Bedroom—CeilingJoints
➢ Unit 4715:
Lower Level, Northeast Bedroom — CeilingJoints
➢ Unit 4715:
Lower Level, Hallway — CeilingJoints
In
• Homogeneous Area 3:
Homogeneous Areas
(HA in RED is asbestos containing)
Drywall w/ Popcorn Surfacing Material
➢ Unit4715:
Main Level, Living Room—Walls
➢ Unit4715:
Main Level, Kitchen—Walls
➢ Unit4715:
Main Level, Dining Room—Walls
➢ Unit4715:
Main Level, Laundry Room—Ceiling and Walls
➢ Unit4715:
Upper Level, Northeast Bedroom —Walls
➢ Unit4715:
Upper Level, Northwest Bedroom —Walls
➢ Unit4715:
Upper Level, Hallway—Walls
➢ Unit4715:
Main Level, Stairwell —Walls
• Homogeneous Area 4: Drywall w/ Joint Compound
➢
Unit4715:
Main Level, Living Room —Wall Joints
➢ Unit4715:
Main Level, Kitchen —Wall Joints
➢ Unit4715:
Main Level, Dining Room —Wall Joints
➢ Unit4715:
Main Level, Laundry Room—Ceiling and Wall Joints
➢ Unit4715:
Upper Level, Northeast Bedroom —Wall Joints
➢ Unit4715:
Upper Level, Northwest Bedroom —Wall Joints
➢ Unit4715:
Upper Level, Hallway —Wall Joints
➢ Unit4715:
Main Level, Stairwell —Wall Joints
• Homogeneous Area 5: Drywall w/ Orange Peel Surfacing Material
➢ Unit4715: Upper Level, Bathroom—Ceiling and Walls
• Homogeneous Area 6: Drywall w/ Joint Compound
➢ Unit4715: Upper Level, Bathroom—Ceiling and Wall Joints
• Homogeneous Area 7: Drywall w/ Heavy Orange Peel Surfacing Material
➢ Unit 4715:
Lower Level, Hallway—Walls
➢ Unit 4715:
Lower Level, Bathroom —Walls
➢ Unit 4715:
Lower Level, Northeast Bedroom —Walls
➢ Unit 4715:
Lower Level, Northwest Bedroom —Walls
• Homogeneous Area 8: Drywall w/ Joint Compound
➢ Unit 4715:
Lower Level, Hallway—Wall Joints
➢ Unit 4715:
Lower Level, Bathroom —Wall Joints
➢ Unit 4715:
Lower Level, Northeast Bedroom —Wall Joints
➢ Unit 4715:
Lower Level, Northwest Bedroom —Wall Joints
5
1,332 sf
N/A
200 sf
N/A
654 sf
N/A
Homogeneous Areas
(HA in RED is asbestos containing)
• Homogeneous Area 9: Drywall w/ Joint Compound N/A
➢ Unit 4715: Main Level,Garage —Ceiling and Wa I I Joints
• Homogeneous Area 10: Sheet Vinyl Flooring 105 sf
➢ Unit 4715: Upper Level, Bathroom — Floor
➢ Unit 4715: Lower Level, Bathroom —Floor
• Homogeneous Area 11: Sheet Vinyl Flooring 81 sf
➢ Unit 4715: Main Level, Laundry Room—Floor
• Homogeneous Area 12: Blown in Insulation N/A
➢ Unit 4715: Main Level, Attic—Floor
• Homogeneous Area 13: Wall Tile w/ Grout 45 sf
➢ Unit 4715: Upper Level, Bathroom —Walls
• Homogeneous Area 14: Sheet Vinyl Flooring 160 sf
➢ Unit 4715: Main Level, Kitchen—Floor
• Homogeneous Area 15: Drywall w/ Brush Stomp Surfacing Material 1,127 sf
➢ Unit 4713: Living Room—Walls
➢ Unit 4713: LaundryRoom—CeilingandWalls
➢ Unit 4713: Southwest Bedroom —Walls
➢ Unit 4713: Southeast Bedroom — Walls
➢ Unit 4713: Kitchen — Walls
• Homogeneous Area 16: Drywall w/ Joint Compound N/A
➢ Unit 4713: Living Room —Wall Joints
➢
Unit4713: Laundry Room —Ceilingand Wall Joints
➢ Unit 4713: Southwest Bedroom — Wall Joints
➢ Unit 4713: Southeast Bedroom — Wall Joints
➢ Unit 4713: Kitchen — Wall Joints
• Homogeneous Area 17: Drywall w/ Popcorn Surfacing Material 567 sf
➢ Unit 4713: Living Room—Ceiling
➢ Unit 4713: Kitchen—Ceiling
➢ Unit 4713: Southwest Bedroom —Ceiling
➢ Unit 4713: Southeast Bedroom—Ceiling
6
Homogeneous Areas
(HA in RED is asbestos containing)
• Homogeneous Area 18: Drywall w/ Joint Compound N/A
➢ Unit 4713: Living Room –CeilingJoints
➢ Unit 4713: Kitchen –CeilingJoints
➢ Unit 4713: Southwest Bedroom–CeilingJoints
➢ Unit 4713: Southeast Bedroom–CeilingJoints
• Homogeneous Area 19: Drywall w/ Orange Peel Surfacing Material 353 sf
➢ Unit 4713: Bathroom—Ceiling and Walls
➢ Unit 4713: Kitchen –Walls
• Homogeneous Area 20: Drywall w/ Joint Compound N/A
➢ Unit 4713: Bathroom—Ceiling and Wall Joints
➢ Unit 4713: Kitchen –Wall Joints
• Homogeneous Area 21: Wall Tile w/ Grout N/A
➢ Unit 4713: Kitchen –Walls
• Homogeneous Area 22: Wall Tile w/ Grout N/A
➢ Unit 4713: Bathroom–Walls
• Homogeneous Area 23: Sheet Vinyl Flooring 196 sf
➢ Unit 4713: Kitchen – Floor
➢ Unit 4713: Laundry Room–Floor
• Homogeneous Area 24: Sheet Vinyl Flooring 45 sf
➢ Unit 4713: Bathroom–Floor
• Homogeneous Area 25: Wallpaper w/ Adhesive N/A
➢ Unit 4713: Southwest Bedroom –North Wall
• Homogeneous Area 26: Cove Base w/ Adhesive N/A
➢ Unit 4713: Kitchen –Walls
➢ Unit 4713: Laundry Room –Walls
Sampling
The Inspector determined that it was necessary to collect 65 bulk samples from the various homogenous areas (see
the Asbestos Sampling below for exact areas). All samples were submitted to an accredited third -party independent
laboratory. The laboratory results are attached to and incorporated into this report.
7
Testing Locations
(Samples in RED are asbestos containing)
SM = Surfacing Material SD = Significantly Damaged ND = None Detected
TSI = Thermal Systems Insulation D = Damaged
MM = Miscellaneous Material G = Good
Material
Sample
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4715:
Main Level,
1C
Living Room —
Ceiling
Unit 4715:
Main Level,
2C
Kitchen —
Ceiling
Unit 4715:
3C
Upper Level,
D wallw/
ry
Gray
Hallway—
Compound
1
SM
Popcorn
Yes
Damaged
Ceiling
g
3/
Texture
Chrysotile
Unit 4715:
Upper Level,
4C
Northeast
Bedroom —
Ceiling
Unit 4715:
Lower Level,
5C
Northeast
Bedroom —
Ceiling
Off White
Unit 4715:
Joint
Upper Level,
Compound3
6JC
Northwest
%Chrysotile
Bedroom —
White
Ceiling Joint
Drywall w/ Joint
Foamy
2
MM
Yes
Damaged
Compound
Texture w/
Unit 4715:
White/black
Lower Level,
charred
7JC
Northwest
paint
Bedroom —
8
Ceiling Joint
Chrysotile
SM = Surfacing Material SD = Significantly Damaged ND = None Detected
TSI = Thermal Systems Insulation D = Damaged
MM = Miscellaneous Material G = Good
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4715:
Main Level,
BW
Living Room —
West Wall
Unit 4715:
Main Level,
9W
Kitchen —
North Wall
Unit 4715:
Upper Level,
Drywall w/
White
3
10W
Northwest
SM
Brush Stomp
Yes
Damaged
Compound
Bedroom —
4%
North Wall
Texture
Chrysotile
Unit 4715:
Upper Level,
11W
Northeast
Bedroom —
East Wall
Unit 4715:
Main Level,
12W
Laundry Room —
South Wall
Unit 4715:
Main Level,
13JC
Living Room —
Gray
North Wall Joint
Drywall w/ Joint
Compound
4
MM
Yes
Damaged
Unit 4715:
Compound
3%
Main Level,
Chrysotile
141C
Stairwell —
East Wall Joint
Unit 4715:
Upper Level,
15C
White
Bathroom —
C
Ceiling
Compound
Unit 4715:
Drywall w/
Chryso
Chrysotile
s
l
Upper Level,
5
16W
SM
Orange Peel
Yes
Damaged
Bathroom
Texture
White Joint
West Wall
Compound
Unit 4715:
3%
17W
Upper Level,
Chrysotile
Bathroom —
East Wall
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
1k
(TSI,SM,MM)
Content
a
Unit 4715:
White
Upper Level,
Compound
181C
Bathroom —
3%
North Wall Joint
Chrysotile
Drywall w/ Joint
6
MM
Yes
Damaged
Unit 4715:
Compound
White Joint
19JC
Upper Level,
Compound
Bathroom —
Ceiling Joint
Chrysotile
Unit 4715:
Lower Level,
20W
Northeast
Bedroom —
East Wall
Unit 4715:
Drywall w/
White
7
Lower Level,
SM
Orange Peel
Yes
Damaged
Compound
21W
Northwest
3%
Bedroom —
Texture
Chrysotile
West Wall
Unit 4715:
Lower Level,
22W
Hallway—
South Wall
Pink
Unit 4715:
Compound
Lower Level,
3%
23JC
Bathroom —
Chrysotile
East Wall Joint
White
Drywall w/ Joint
Compound
8
MM
Yes
Damaged
Compound
3%
Unit 4715:
Chrysotile
Lower Level,
White Joint
241C
Stairwell —
Compound
West Wall Joint
3%
Chrysotile
Off White
Compound
25JC
3%
Unit 4715:
Main Level,
Drywall w/ Joint
Chrysotile
9
MM
Yes
Damaged
Off White
Garage—
Compound
Joint
26JC
West Wall Joints
Compound
3%
Chrysotile
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
10
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4715:
Upper Level,
27F
Bathroom —
Gra y
Floor
Sheet Vinyl
Fibrous
10
MM
Yes
Damaged
Material
Unit 4715:
Flooring
o
60/
28F
Lower Level,
Chrysotile
Bathroom —
B
Floor
29F
Unit 4715:
Main Level,
Sheet Vinyl
11
MM
Yes
Damaged
ND
Laundry Room —
Flooring
30F
Floor
311
Unit 4715:
Main Level,
12
MM
Blown in Insulation
Yes
Damaged
ND
Attic —
321
Floor
33WT
Unit 4715:
13
Upper Level,
MM
WallTilew/Grout
No
Damaged
ND
Bathroom —
3gWT
West Wall
35F
Unit 4715:
Main Level,
Sheet Vinyl
14
MM
Yes
Damaged
ND
Kitchen—
Flooring
36F
Floor
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
11
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4713:
37W
Living Room —
West Wall
Unit 4713:
Southwest
38W
Bedroom —
North Wall
Drywall w/
Off White
Unit 4713:
Compound
15
Southeast
SM
Brush Stomp
Yes
Damaged
39W
Bedroom —
Texture
3%
Chrysotile
West Wall
Unit 4713:
40W
Laundry Room —
North Wall
Unit 4713:
41C
Laundry Room —
Ceiling
Unit 4713:
42JC
Living Room —
Off White
North Wall Joint
Drywall w/ Joint
Compound
16
MM
Yes
Damaged
Unit 4713:
Compound
3%
43JC
Laundry Room—
Chrysotile
North Wall Joint
Unit 4713:
Southwest
44C
Bedroom —
Ceiling
White
Unit 4713:
Drywall w/
Foamy
17
45C
Southeast
SM
Popcorn
Yes
Damaged
Texture w/
Bedroom —
Texture
white Paint
Ceiling
7%
Chrysotile
Unit 4713:
46C
Living Room —
Ceiling
Off White
Unit 4713:
Compound
47JC
Living Room —
3%
Ceiling Joint
Chrysotile
Drywall w/ Joint
18
MM
Yes
Damaged
Tan Foamy
Compound
Texture w/
Unit 4713:
48JC
Kitchen—
white paint
Ceiling Joint
7%
Chrysotile
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
12
Testing Locations
(Samples in RED are asbestos containing)
13
Material
Sample
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
Unit 4713:
49W
Bathroom — North
Wall
Drywall w/
Off White
Unit 4713: Kitchen
19
SOW
—
SM
Orange Peel
Yes
Damaged
Compound
North Wall
Texture
3/
Chrysotile
Unit 4713:
51W
Kitchen—
West Wall
Off White
Unit 4713:
Compound
52JC
Bathroom — North
3%
Wall Joint
Chrysotile
wall w/
Dryompound Joint
20
MM
Yes
Damaged
Off White
Compound
Unit 4713: Kitchen
Joint
53JC
—
Compound
South Wall Joint
3%
Chrysotile
54WT
Unit 4713: Kitchen
21
—
MM
WaIlTilew/Grout
No
Damaged
ND
South Wall
SSWT
56WT
Unit 4713:
22
Bathroom—South
MM
WaIlTilew/Grout
No
Damaged
ND
Wall
57WT
Unit 4713:
58F
Laundry Room —
Floor
23
MM
Sheet Vinyl Flooring
Yes
Damaged
ND
Unit 4713: Kitchen
59F
—
Floor
Tan/multi-
colored
60F
Sheet Vinyl
w/ Off
Unit 4713:
White
24
Bathroom —
MM
Sheet Vinyl Flooring
Yes
Damaged
Fibrous
Floor
Backing
61F
Material
15%
Chrysotile
13
Testing Locations
(Samples in RED are asbestos containing)
SM =
Surfacing Material
SD
Material
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
Sample
Good
Material
HA
Sample
Category
Friable
Condition
Asbestos
Location
Description
ID
(TSI,SM,MM)
Content
62WP
Unit 4713:
Off White
Southwest
Wallpaper w/
Compound
25
Bedroom—
MM
Adhesive
yes
Damaged
3%
63WP
North Wall
Chrysotile
64CB
Unit 4713:
Cave Base w/
26
LaundryRoom—
MM
No
Damaged
ND
Adhesive
South Wall
65CB
SM =
Surfacing Material
SD
= Significantly Damaged ND = None Detected
TSI =
Thermal Systems Insulation
D =
Damaged
MM
= Miscellaneous Material
G =
Good
14
Conclusion
Asbestos containing building materials WERE found in the samples analyzed by the laboratory. The affected building materials DO
need to be removed by a certified abatement company according to Regulation 8 of CDPHE. Caution should always be taken and
OSHA personal protective equipment should be used during any removal of sampled building materials.
Based on said analysis, ELEMENT Building Sciences has determined that approximately 265 square feet of asbestos containing
material has been disturbed in the kitchen and living room and possibly become airborne. According to CDPHE Regulation 8, the
amount of asbestos containing material disturbed has resulted in a MAJOR SPILL. It is the recommendation of ELEMENT Building
Sciences that this disturbance be reported to the Colorado Department of Public Health and Environment and the Colorado Air
Pollution Control Division (per CDPHE Reg 8 Sec III.T.1.c) as soon as possible.
CDPHE Colorado Environment Release and Incident Reporting Line (24-hour)
- +1 (877) 518-5608
- cdphe.asbestos(@state.co.us
Colorado Air Pollution Control Division
- +1 (303) 692-3100
- cd phe.commentsapcdPstate.co.us
For more information on possible spill response, please see CDPHE Regulation 8:
https://www.colorado.gov/pacific/sites/default/files/AP ASB Regulation -No -8 -Part -B -Asbestos -amended -December -21 -2007 -
effective -1 a n ua ry-30-2008. pdf
ELEMENT assumes no liability for any loss, injury, claim or damages arising directly or indirectly from any use or reliance on this rep
ort or the opinions expressed herein. ELEMENT makes no risk assessment, warranty
guarantee or insurance policies of any kind express or implied. This report is limited only to the samples taken
and locations sampled. There are no risk assessments, warranties, guarantees, or insurance available or provided by ELEMENT.
Additional sampling may be needed to further identify other pollutants, or other mold/fungus affected areas inside the subject prop
e rty.
This report was prepared pursuant to the contract ELEMENT has with the client. That contractual relationship
included an exchange of information about the subject property that was unique and between ELEMENT and its
client and serves as the basis upon which this report was prepared. Because of the importance of the
communication between ELEMENT and its client, reliance or any use of this report by anyone other than the client, for
whom it was prepared, is prohibited and therefore not foreseeable to ELEMENT.
15
c ' W+E
61 S
w
N
W+E
s
9
n
E
J
E
°o
11
e
E
E
A�
F1
E
91
Overview of Unit 4715
Overview of Unit 4715: Main Level, Living Room
Overview of Unit 4715: Main Level, Kitchen
Overview of Unit 4715: Main Level, Dining Room
Overview of Unit 4715: Laundry Room
19
Overview of Unit 4715: Garage
Overview of Unit 4715: Upper Level, Northeast Bedroom
Overview of Unit 4715: Upper Level, Bathroom
Overview of Unit 4715: Upper Level, Northwest Bedroom
Overview of Unit 4715: Stairwell to Lower Level
Overview of Unit 4715: Lower _vel, Bathroom
G.=rview of Unit 4715: Lower Level, Northwest Bedroom
20
Overview of Unit 4715: Lower Level, Northeast Bedroom
Overview of Unit 4713
Overview of Unit 4713: Living Room
Overview of Unit 4713: Kitchen
21
Overview of Unit 4713: Laundry Room
Overview of Unit 4713: Bathroom
Overview of Unit 4713: Southwest Bedroom
Overview of Unit 4713: Southeast Bedroom
22
September N, 9020
Pr
REAS recent
yiort
,�.o s
201
FrtRul UeaanpYm:
Sol
REI LASS
Water—
Reservoirs
Environmental,
Inc.
September N, 9020
Pr
REAS recent
yiort
,�.o s
201
FrtRul UeaanpYm:
Sol
Ryan fimmp
Sciences
BBN WOIfl Ct
side 140
abnormal r CO 8OD31
bear Main
Reemoo-e Environmental Inc is an analytical phoaron the edlled for the analysis M IndWFW Happen and
Emlronmemal m ces by the National voluntary Laboratory A:aetlpa4on Program (it"LAP), Lab Cape
1010930 for Transmission ElHron Microscopy (i and Polarized Light Mlcrampy(PLM] anodes, and Me
Amerlian In ouNal Myglme Assn on (/JXAJ. Lab 10 lC16A - paymen Om CeNOpu= NW !a Please
Contrast Mlvosccpy 1POMt analysts This tarred is currently pmficlern In ash Pmfidenry Testing and PAT
Programs t�PemmeN
Missouri Environmental Inc. las anayieb the rollwnne samples for asbestos content as per your requeden
neNets has Isperin composed In repeal accordance with Me appropriate migratio9y as araletl In Ne
atl ed analysis bible. The not have been submkedbyour office.
RES am W-0 is the job number awgretl to this sway. This open is¢neiderea highly centro lal and Me
orp, pmRerly or any pan of gr dy w�
other those entry cfcrM1 The results reacnsanln thee departure apply to the ampler analysed
Personal ryytgP or any agenryol
This et be Me neypod shat not be a(petluer except
in
ill yo by
Me US repan N ry repmdumn event M n M equl !m
N14 `^'hoN wipe
r@servrvrs Environmerol, Inc this rep rill be dcsycs fr e c callsistytlrys unless longvsbagae rryuesred
If you Fere airyquesllms adaN this report pleax bel tree N a113g396f-1986.
RESERVOIRS ENVIRONMENTAL ING
2C NSA "i pAr Sub, Bull
3c N,`n.bAAd,kC1SWJk1
4, NSA All BE Seem bubble,
11 Kbinkeedpilluel
11 bublukeekeepull
TABLE ELSE BULK fidell All Ell COMl
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
01.1
SEES Being SumenceS
bee Plujukulki `0
I'll,
„a,.a.,o.�,
Turmrmn±
Pi
111 A 1
2C NSA "i pAr Sub, Bull
3c N,`n.bAAd,kC1SWJk1
4, NSA All BE Seem bubble,
11 Kbinkeedpilluel
11 bublukeekeepull
TABLE ELSE BULK fidell All Ell COMl
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
TABLE ELSE BULK fidell All Ell COMl
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
AS w
m All, Ansubbel Be 11 .1 Rl
1 11 Jun uni Be oant 'Equi
Me Ab Mi pur Sell Subbel
1 "flebeckerennedllem, 11 HE 11 14,C W Ani AS Sent EASE.,
ill Kor EBul per 11 En' ll
11AN AS Ani AS Sent Requ.
1
to I T A An All Ole
III Il
ullon,
Element ill All
Client
L
Ill
Joe, examop .. Rece.
I.Aboomber 1, MI
Joint
Pool
Date Some es Annobed
Ni
to I T A An All Ole
Fee Job No An
III Il
CIA,
Ekentrentill.demikerente
Client
L
Ill
Joe, examop .. Rece.
I.Aboomber 1, MI
Joint
Pool
Date Some es Annobed
Ni
I been, Pat
Motenj vel
Diet.
Di
10
E A� Abele .11AI 75
ND
DO
10.0
No Mal,i er Centel
2"
DAMCDAWAirCIDIFFICA.
Fee Job No An
III Il
CIA,
Ekentrentill.demikerente
01 .1 Peel beenteneen
Ill
Joe, examop .. Rece.
I.Aboomber 1, MI
Joint
Pool
Date Some es Annobed
I.."r 1. JU21
a
Di
RESERVOIRS ENVIRONMENTAL INC
III
I
Ageteency.
beer
be,
Ment
grand,
I1AddGyd3dNI ll "I
Carl
MA 9 Grateeld. Gray depead...
RESERVOIRS ENVIRONMENTAL INC
III
I
Ageteency.
beer
be,
Ment
grand,
I1AddGyd3dNI ll "I
"I any",
I Off 11 Fail 1
11
1
IN
I Gray I by buyer al P rear al 1 11
11
In
r
H A cranially CIS NO real MWW 11
11
1
INC
ISF
red ben Gerald be (Sugar Ruder
RESERVOIRS ENVIRONMENTAL INC
CI da Pr lad Day nual
Ment
grand,
I1AddGyd3dNI ll "I
"I any",
I Off 11 Fail 1
11
1
IN
I Gray I by buyer al P rear al 1 11
11
In
r
H A cranially CIS NO real MWW 11
11
1
INC
D
11.1
Ell Bk1dEg4l
all,
L
01.1 PulEl
11.1
D
all,
L
01.1 PulEl
11.1
41,
A fil' hum cumuli. 1
17
D
01.1 PulEl
11.1
D
41,
A fil' hum cumuli. 1
17
a., EBKUKABWdflL2Kexes
�ww
F K
VILId
,. ,.m.ImL ,..
;
a., EBKUKABWdflL2Kexes
RESERVI ENVIRONMENTAL INC
1I I bol. OR
SRI do
ISI
®.
oRpooffoRr M, MD
OF
1I I bol. OR
SRI do
ISI
RISPISS
OF
III ASSISSed por Clow DID
1I I bol. OR
T@eservairs Envimnmen[ai, Inc. RES Joc x anzaz_
,
_ ...
..
AL 31
._
....,f
t
kim
s KU31 kN ..........1
m_
{
.:.
i�
:.
M
li. ink
�I
i° esti il�sisii
�FIR
ass
4iI�li9iIiial
i�iI
i
��
his ai83P8�Ra IiI
�a
i�1
i t
J
iii ii J
J
L I....IJ
.... ....
...
�
iit rr —ii
t
Yrs �
I
III II "II
I
FI"'I]
22 T
1
"kin
:1
11t 11 -11
i
:t i t 1
Z
,
_ ...
..
Element Building Sciences (EBS) assumes no liability for any loss, injury, claim or damages arising directly or indirectly
from any use or reliance on this report or the opinions expressed herein. EBS makes no risk assessment, warranty,
guarantee or insurance policies of any kind, express or implied. This report is limited only to the samples taken and
locations sampled. There are no risk assessments, warranties, guarantees, or insurance available or provided by EBS.
Additional sampling may be needed to further identify other pollutants, or other mold/fungus affected areas inside the
subject property.
This report was prepared pursuant to the contract EBS has with the client. That contractual relationship included an
exchange of information about the subject property that was unique and between EBS and its client and serves as the
basis upon which this report was prepared. Because of the importance of the communication between EBS and its client,
reliance, or any use of this report by anyone other than the client, for whom it was prepared, is prohibited and therefore
not foreseeable to EBS. No warranty is made. EBS liability and that of contractors and subcontractors arising from any
service rendered hereunder shall not exceed the total fee paid by the client to EBS.
Thank you for the opportunity to work with you on this project. Please call at 720.537.0963 with any questions or
concerns. Thank you.
Sincerely,
Ryan Crump
Element Building Sciences
Colorado State Certified
Asbestos Inspector, 25005
33