Loading...
HomeMy WebLinkAbout01/18/2011RENEWAL HE�-7:. RIDGE Progress Through Partnership AGENDA WHEAT RIDGE URBAN RENEWAL AUTHORITY January 18, 2011 Notice is hereby given of a Public Meeting to be held before the City of Wheat Ridge Urban Renewal Authority on Tuesday, January 18, 2011 at 6:00 p.m., in the Council Chambers of the Municipal Building at 7500 West 29th Avenue, Wheat Ridge, Colorado. Individuals with disabilities are encouraged to participate in all public meetings sponsored by the City of Wheat Ridge. Call Heather Geyer, Public Information Officer at 303 -235 -2826 at least one week in advance of a meeting if you are interested in participating and need inclusion assistance. 1. Call the Meeting to Order 2. Roll Call of Members 3. Approval of Minutes —December 7, 2010 4. Public Forum (This is the time for any person to speak on any subject not appearing on the agenda. Public comments may be limited to 3 minutes.) 5. Introduction of New Economic Development/Urban Renewal Manager — Steve Art 6. 44 and Wadsworth Redevelopment Demolition Technical Approach — Weston Solutions 7. Community Development Referral —Zone Change - RV America (11808 W. 44 Avenue) 8. Resolution 01 -2011— Designated Public Place for the Posting of Meeting Notices 9. Resolution 02 -2011— Approving a Supplemental Budget Appropriation for 2010 10. Other Matters 11. Adjournment MINUTES RENEWAL WHEAT RIDGE December 7, 2010 1. Call the Meeting to Order The meeting of Renewal Wheat Ridge was called to order by Chair Adams at 6:00 p.m. in the council chambers of the Municipal Building, 7500 West 29 Avenue, Wheat Ridge, Colorado. 2. Roll Call of Members Board Members Present: Rick Adams James Bahrenburg Janet Leo Walt Pettit Tom Radigan Larry Schulz (arrived 6:10 pm) Board Members Absent: Becky Bye Also Attending: Patrick Goff, Executive Director Elizabeth Gross, RWR Attorney Ann Lazzeri, Recording Secretary 3. Approval of Minutes — October 19, 2010 It was moved by Walt Pettit and seconded by Janet Leo to approve the minutes of October 19, 2010 as presented. The motion carried unanimously. 4. Public Forum (This is the time for any person to speak on any subject not appearing on the agenda.) There were no citizens present to address the Board. 5. Amended and Restated Master Development Agreement — Weston Solutions In order to continue the relationship with Weston Solutions, Inc. for the redevelopment project located at 7340, 7540 and 7300 West 44' Avenue, staff drafted an Amended and Restated Master Development Agreement. Patrick Goff reviewed the amended agreement. Extensive discussion followed. Renewal Wheat Ridge December 7, 2010 It was moved by Janet Leo and seconded by James Bahrenburg to approve the amended and re- stated master development agreement with Weston Solutions, Inc. The motion carried unanimously. 6. 2011 Proposed Budget Adoption — Public Hearing Chair Adams opened the public hearing on the 2011 proposed budget. There were no members of the public present. The public hearing was closed. It was moved by Janet Leo and seconded by Larry Schulz to approve Resolution 02 -2010, a resolution enacting a budget and appropriation for the year 2011 for the Town Center and Wheat Ridge Cyclery Project funds. The motion passed unanimously. 7. New Business It was moved by Janet Leo and seconded by Walt Pettit to authorize Patrick Goff to make payments one and two in the total amount of $185,000 from the 2010 budget that will be amended at the next Renewal Wheat Ridge meeting. The motion passed unanimously. 8. Other Matters • Chair Adams inquired about the Economic Development Director position. Patrick Goff reported that it looks like the position could be filled by the first of the year. 9. Adjournment The meeting was adjourned at 7:35 p.m. The next meeting will be held January 18, 2011 unless the need arises for another meeting in December, 2010. Rick Adams, h. Renewal Wheat Ridge December 7, 2010 Ann Lazzeri, Secretary -2— RE N EWAL r l —Js CR 4 Progress Through Partnership MEMORANDUM TO: Renewal Wheat Ridge Board Members FROM: Patrick Goff, Executive Director RE: 44 and Wadsworth Redevelopment — Demolition Technical Approach DATE: January 13, 2011 On December 7, 2010, Renewal Wheat Ridge (RWR) approved an Amended and Restated Master Development Agreement with Weston Solutions, Inc. to designate Weston as the sole and exclusive Redeveloper of the property located at 7340, 7540 and 7300 West 44` Avenue. The Amended Agreement details additional Redeveloper obligations including the abatement and demolition of the existing buildings and infrastructure on site. Weston Solutions will be at the January 18 meeting to review with the Board the Technical and Management Approach for this task. A Request for Proposal for this work was released on January 7th. Bids are due to Weston on January 28 Weston will return to the February 1 St RWR meeting with actual bid numbers and staff will have drafted an Infrastructure Improvement Agreement which will authorize Weston to proceed with the demolition and abatement work. Attachments: 1. Weston Solutions Technical and Management Approach 2. Site Demolition Plan 3. Subcontractor Solicitation 4. Project Schedule WESTON SOLUTIONS, INC TECHNICAL AND MANAGEMENT APPROACH for DEMOLITION OF EXISTING BUILDINGS AND INFRASTRUCTURE AT 44 AND WADSWORTH REDEVELOPMENT SITE 7340 WEST 44 AVENUE WHEAT RIDGE, COLORADO 11 January 2011 Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 (303) 729 -6100 SOLUTIONS 1.0 INTRODUCTION This Technical and Management Approach document defines the roles and responsibilities for Weston Solutions, Inc. ( WESTON) for the demolition and /or deconstruction activities at the 44`'' and Wadsworth Redevelopment Site located at 7340 W. 44` Avenue in Wheat Ridge, Colorado. WESTON will act as general contractor for this project. 2.0 TECHNICAL AND MANAGEMENT APPROACH The general scope of the project is for WESTON to provide complete demolition of the site located at 44 and Wadsworth in Wheat Ridge. The intent of this demolition project is to prepare the site for future new construction (see attached Request for Proposal documents and Statement of Work for detailed description of activities). To achieve this, demolition activities will include: • Asbestos abatement and demolition of the antique mall. • Demolition of the auto shop located in the northeast area of the site. • Removal and backfill of any building foundations removed. • Removal of all site features (parking lot lights, walls, signs, bollards). • Removal of all concrete and asphalt. • Removal of all utilities that will not impact municipal activities. In addition to demolition, WESTON will leave the site in "subgrade" condition, and will provide site seeding to reduce erosion impacts. This will prepare the site for new construction with minimal future activities. As an option to demolition, WESTON has requested the contractors provide a cost for Green Deconstruction of the site. WESTON intends to green deconstruct this site if budgets allow. By doing this, WESTON will be able to divert at least 75% of waste produced in demolition from landfills, and will recycle and or reuse any materials as appropriate. This will also provide credits toward LEED certification of any new buildings constructed on the site. 2.1 WESTON Provided Services WESTON will act as the general contractor and liaison to the City of Wheat Ridge (Renewal Wheat Ridge) for all aspects of this demolition project. WESTON will provide the following services for this project: Develop a not -to- exceed price based on a Cost -Plus Fixed Fee (CPFF) basis for the successful completion of this project. Develop and maintain a project schedule. Coordinate project status meetings. 44 and Wadsworth Redevelopment Site Demolition Technical and Management Approach 11 January 2011 Page 2 of 7 fll \l[tllf • Provide all aspects of project management for the project, including project management, full -time site superintendent, health and safety, quality control, project controls, waste management reporting, and routine daily reporting. • Provide a Contractor's Progress, Status, and Management Report (CPSMR). • Provide contracting for all necessary entities needed to successfully complete this project. • Coordinate utility disconnections. • Provide site fencing and security. • Prepare and submit a Storm Water Pollution Prevention Plan (SWPPP). • Obtain and maintain all other required permits in cooperation with subcontractors. • Initiate, manage and maintain site health and safety and quality measures. 2.2 Weston Subcontracted Services WESTON plans to contract out the work items below. All subcontractors must meet and comply with all of WESTON's health and safety and quality procedures. All contractors must be qualified within WESTON's subcontractor qualification system, SubTrack, prior to receiving award. • Asbestos abatement and verification • All other site demolition activities • Traffic control • Geotechnical testing 3.0 PROJECT TEAM AND SCHEDULE 3.1 Project Management Team WESTON will provide an experienced project management team for all aspects of the site demolition project at 44`" and Wadsworth. The following personnel will support the successful completion of demolition activities, and will perform work on a CPFF basis as outlined in the Master Development Agreement. Project Manager: Nick Moore P.E. will provide project management for this project. He will act as liaison between WESTON and Renewal Wheat Ridge. Mr. Moore will ensure that demolition and abatement activities are completed on schedule and will address any issues that may arise during demolition. Mr. Moore will coordinate activities with the project team, Renewal Wheat Ridge, and the community in order to provide the successful completion of this project. Project Engineer: Jared Johnson P.E. will provide project engineering and project management support for this project. Mr. Johnson will be responsible for subcontractor selection and contracting. He will review all work plans and submittals from subcontractors, and will develop and maintain a detailed construction schedule in cooperation with demolition and asbestos 44'' and Wadsworth Redevelopment Site Demolition Technical and Management Approach 11 January 2011 Page 3 of 7 abatement contractors. Mr. Johnson will provide progress reports and invoicing documents to Renewal Wheat Ridge. He will also oversee all on -site activities, will manage the Site Superintendent, and ensure all site activities are completed in accordance with WESTON's health and safety and quality control policies and procedures. Site Superintendent: Mark Wiebe will be the Site Superintendent for this project. His responsibilities will include site coordination and supervision of contractors, health and safety supervision and reporting, quality control, completion of daily reports, and preparation of waste reporting documents. Mr. Wiebe will be on -site for all demolition activities and will ensure all activities performed on -site are in accordance with WESTON's policies and procedures for health and safety and quality control. Health and Safety Officer: Mike Stuart, WESTON's Central Division Health and Safety Officer will provide upfront health and safety planning, as well as periodic health and safety audits of the site. Mr. Stuart will work closely with the project management team to ensure all work activities conducted for this project are in accordance with WESTON's health and safety policies and procedures. 3.2 Schedule A preliminary schedule is attached. WESTON intends to begin physical site demolition on 14 February 2011, and intends to complete demolition activities by 15 April 2011. Any changes in schedule will be coordinated with Renewal Wheat Ridge. 4.0 PLANS, REPORTS, AND DELIVERABLES Safety is one of WESTON's core values. We care for our co- workers, families, clients, and subcontractors and are focused on being safety leaders wherever we live and work. We thrive in a "safety first and all- the - time" culture and accept personal responsibility for creating a safe environment. For these reasons, WESTON's safety programs and requirements apply for subcontractors as they do for WESTON employees. Due to the nature of the work, special attention will be given to the Health and Safety procedures established before work is initiated to the following key areas: • Clearly delineating active construction zones • Addressing noise and air pollutant mitigation actions • Safety procedures during demolition and offsite disposal • Safety and coordination of demolition, excavation and grading activities 4.1 Health and Safety WESTON's Environmental Health and Safety (EHS) Group is proactive in assessing current EHS Programs and setting strategies for years ahead. WESTON implements this EHS Program to fulfill our commitment to employees, subcontractors, and a diverse and dynamic range of clients to provide safe and healthy working conditions. Emphasis is also directed to continuous 44''' and Wadsworth Redevelopment Site Demolition Technical and Management Approach I 1 January 2011 Page 4 of 7 environmental compliance, continual improvement, and pollution prevention strategies. The EHS Program that will be implemented for this project is presented in three parts: • Part 1 - Health and Safety Program • Part 2 - Safety Manual • Part 3 - Environmental Protection Program The following sections summarize the three components of WESTON's EHS Program. Health and Safety Program It is WESTON's policy to assure that its employees are furnished a place of employment in which they are secure from recognized risks to their health and safety. In addition, WESTON's employees are required to conduct work activities in compliance with applicable safety regulations, and in a manner that will allow WESTON to achieve its goal for all employees and subcontractors to work safely — 100% of the time — in an environmentally responsible manner. WESTON has implemented a behavior -based safety (BBS) program where we are all responsible for each other, focusing on behaviors and intervention techniques to improve behavioral processes. Within BBS, our employees create high quality connections with one another, team members, and stakeholders to foster an active, caring culture. Commitment is higher and we help each other be safe every minute of every day. By achieving this goal, we will achieve our expectation of zero incidents. All employees assume a safety leadership role and are responsible for the safety of co- workers, our team members, and stakeholders. WESTON's EHS management system encompasses quality, environmental preservation, health, and safety to execute projects without harm to persons, property, or the environment. WESTON encourages the Plan, Do, Check, Act (PDCA) model for project planning and implementation as standard work practice for every job. The four elements of the PDCA model include: • Plan: Plan ahead, analyze, and predict results. • Do: Execute the plan, taking small steps in a controlled environment. • Check: Review the results, compare against the plan. • Act: Take action to maintain or improve. Safety Manual In the spirit of the EHS program, during project execution, a necessary approach to minimize, control or eliminate the potential for adverse impact to human health and the environment is the use of administrative controls. The primary administrative control is the development and implementation of a site - specific Health and Safety Plan (HASP) that addresses all recognized and anticipated hazards associated with every work assignment. The HASP must be read, understood and implemented by all project personnel and contractors. WESTON field operation procedures will be followed by all project personnel and available on the WESTON EHS Portal. The Site Manager will ensure that a tailgate health and safety briefing covers all work activities scheduled for a particular day. 44 and Wadsworth Redevelopment Site Demolition Technical and Management Approach 11 January 2011 Page 5 of 7 P. �; The HASP is required for all field projects and includes project - specific, task -by -task hazard risk analysis, emergency contingencies, field operating procedures, and background information. The HASP will be reviewed by the appropriate WESTON Safety Professional for approval. WESTON EHS documents are developed and reviewed to ensure document quality and compliance with regulations and client requirements. Project managers ensure version and access control of project documents. As needed, client- or project - specific procedures and responsibilities are established and maintained regarding development and revision of documents. Examples of EHS documents developed by WESTON include, but are not limited to, HASPs; regulatory plans; monitoring, status, and summary reports; and documentation of programmatic data. Environmental Protection Program As part of the comprehensive, integrated EHS Program, this Environmental Protection Program establishes the approach to executing all operations in a manner that protects the safety of employees, the public, and the environment. This Environmental Protection Program provides the framework for accomplishing WESTON's policy for environmental protection and compliance. WESTON will identify operations and activities associated with significant environmental aspects in line with our policy to include storm water control, air monitoring, and hazardous materials handling. The Environmental Protection Program will be augmented with specific plans pertinent to these activities to ensure that they are carried out under specified conditions. Environmental management systems and processes are an integral and essential part of the WESTON EHS Program. WESTON is committed to operating and performing work in accordance with sound environmental practices. To ensure fulfillment of that commitment, the management, employees, and subcontractors to WESTON will adhere to the following principles: • WESTON will prepare a S WPPP that will be active for the extent of the project, and will place Best Management Practices to control surface water pollution during construction activities. • WESTON employees and subcontractors will be responsible stewards of the environment. • WESTON activities, and those of its subcontractors, will be conducted in compliance with applicable federal, state, and local environmental regulations and WESTON procedures. • Environmental hazards will be continuously identified and evaluated during work planning and execution. Effective control of environmental hazards will be implemented for operations. Operational improvements that enhance environmental performance and pollution prevention opportunities will be sought out and implemented on a continuous basis. • Senior Management will monitor the effectiveness of WESTON environmental performance. 4e and Wadsworth Redevelopment Site Demolition Technical and Management Approach 11 January 2011 Page 6 of 7 V"N%AMN Environmental professionals employed by WESTON are prepared to serve as mentors for area business, municipal, and educational organizations. WESTON environmental practices, procedures, and controls will be implemented in concert with, and as a part of all other EHS elements. Through the integration of environmental management throughout all operations, WESTON intends to achieve and maintain ZERO ACCIDENTS (unpermitted discharges or releases to the environment). 4.2 Quality Program WESTON employs a series of clearly defined steps to ensure a proactive Quality Assurance /Quality Control (QA/QC) process throughout the life cycle of every project. These include: (1) at the initiation of the project, clearly define the customer's expectations and standards of quality applicable to the project; (2) document and communicate the QA/QC requirements to the project team and stakeholders; (3) implement QA/QC measures during field execution, with responsible and accountable individuals assigned to enforce quality requirements; (4) monitor compliance through mandatory audits and take corrective actions as needed; (5) capture lessons learned from every project to ensure that QA/QC process is focused on continuous improvement and a "zero tolerance" for quality incidents. 4.3 Project Completion Following successful project implementation, WESTON will perform the following closeout procedures: 1. WESTON will submit two (2) hard copies and one (1) electronic copy of the as -built drawings to the Renewal Wheat Ridge upon completion of the project. 2. WESTON will maintain storm water erosion controls as needed for a period of up to one year upon completion of demolition activities. 3. Working hours shall normally be between 7:45 a.m. and 4:15 p.m., excluding weekends and federal holidays. 4. Due to project requirements, extended hours may be required in order to close an open excavation prior to shutting down for the day. 5. The duration for this project is anticipated to be 60 calendar days of on -site work. See attached schedule. 5.0 Permits and Utilities All necessary permits will be coordinated and obtained by WESTON prior to starting demolition activities for this project. WESTON will provide copies of all permits to Renewal Wheat Ridge. WESTON will also coordinate the shutdown of all utilities on -site that are to be removed. This includes coordination with Xcel energy, Qwest, and Wheat Ridge Water District. All utilities that are to be removed will be cut and capped at the property boundary. 44''' and Wadsworth Redevelopment Site Demolition Technical and Management Approach 11 January 2011 Page 7 of 7 Id IODd �z ¢g €�F w,�oswox�rx e�w. 0 o F R L a A • ��tl F m. a I TTTT 'M am MW SOLUTIONS Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com 7 January 2011 MEMORANDUM FOR: Prospective Contractors FROM: Weston Solutions, Inc. 355 S Teller St, Suite 300 Lakewood, CO 80226 SUBJECT: Request for Proposal (RFP) for Demolition of Existing Buildings and Infrastructure at the 44 and Wadsworth Development Site, Wheat Ridge, Colorado. 1. This is a Request for Proposal (RFP) for the subject project in accordance with the Statement of Work (Exhibit 1) and terms and conditions (Exhibit 4). 2. A site visit will be conducted at the site located on the southeast corner of 44` and Wadsworth, Wheate Ridge, CO on 14 January 2011 at 1000 MST. 3. Questions must be sent to Jared Johnson ( jared .iohnson@westonsolutions.com and Rita Muniz (rita muniz@westonsolutions.com and be received by 19 January 2011 at 1200 MST. 4. Bids are due in response to this RFP no later than 28 January 2011 at 1400 MST. 5. This Task Order will be awarded on a Firm Fixed Price (FFP) basis. Please see the Cost Sheet (Exhibit 2) for desired price breakdown and bid options. Prospective Offerors may submit proposals for all bid items listed, or may submit proposals individually for Demolition, Deconstruction, and Asbestos Abatement. 6. The desired Period of Performance for this Task Order is 60 days from the date of task order award. 7. Liquidated Damages (LD) will be included for this effort. The LD daily amount to be assessed is $1273.80 for each day of delay beyond a milestone delivery due date. 8. Performance and Payment Bonds in the amount of 100% of the contract value will be required. 9. Evaluation Criteria: Weston will award on a best value basis by performing an analysis of factors identified below to determine the contractor that provides the most technically sound and cost effective approach for this demolition project. The following factors in order of relative importance will be used to evaluate bids: a. Price b. Schedule 44 and Wadsworth Redevelopment Site Demolition Request for Proposal 07 January 2011 Page 1 of 2 Weston Solutions, Inc. /CD 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com c. Specific Technical Approach and Capability 10. Please provide in your written proposal the following: a. Completed pricing form (Exhibit 2). b. A schedule of the proposed work. c. Assumptions and Exceptions. d. Proposed team members and subcontractors e. Completed Contract forms provided in RFP (Exhibits 3, 7) f. Letter of Intent from Bonding Company. g. Specific written technical approach. 11. Contractors must be pre - qualified in Weston's contractor database (SubTrack) prior to being eligible for award. Prequalification is mandatory and will be done using the Contractor provided information listed in item 10.e above. 12. Provide an electronic copy of your proposal to Project Manager (PM) Jared Johnson fared iohnsonkwestonsolutions.com Program Manager Nick Moore nicho las.moorekwestonsolutions.com and Procurement Manager Rita Muniz rita.munizkwestonsolutions.com by 28 January 2011 at 1400 MST. 13. Pricing must be valid for a period of 60 days. 14. All available environmental reports are provided in Exhibit 8. Rita Muniz Procurement Manager Exhibit(s): 1. Statement of Work dated 7 January 2011 2. Bid Schedule (pricing form) 3. Representations and Certifications to Offeror Short Form 4. Appendix B — General Provisions — Construction Services 5. Attachment A to Appendix B 6. Attachment B to Appendix B 7. Subcontractor Qualification Questionnaire and W -9 (New Contractors Only)(Or Subcontractor Qualification Update if original Questionnaire is over 1 year old) 8. Phase 1 Environmental Site Assessment and Asbestos Survey 44` and Wadsworth Redevelopment Site Demolition Request for Proposal 07 January 2011 Page 2 of 2 SOLUTIONS Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com WESTON SOLUTIONS, INC EXHIBIT 1 STATEMENT OF WORK for DEMOLITION OF EXISTING BUILDINGS AND INFRASTRUCTURE AT 44 AND WADSWORTH REDEVELOPMENT SITE 7340 WEST 44' AVENUE WHEAT RIDGE, COLORADO Project Number: Contract Number: Task Order: 001 07 January 2011 44"' and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 1 of 11 Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com 1.0 SCOPE This task order (TO) statement of work (SOW) defines the scope of demolition and/or deconstruction activities to complete this TO for Weston Solutions, Inc. ( WESTON) in cooperation with the Wheat Ridge Urban Development Authority (Wheat Ridge). The Contractor shall furnish all plant, supervision, labor, equipment, licenses, and materials necessary to perform demolition and/or deconstruction activities at the 44 and Wadsworth Redevelopment Site located at 7340 W. 44 Avenue in Wheat Ridge, Colorado in accordance with the attached demolition drawing titled 44 and Wadsworth Redevelopment Site Demolition Plan, dated January 2011. Requirements of this TO include efficient management of this TO to include accurate, on -time submittals of contract deliverables and timely identification and solution of impediments to successful project execution. Technical requirements include early involvement in the process to allow for the development of the most cost - effective and technically sound solution. WESTON will rely on the Contractor's expertise in recognizing and addressing problematic issues and successful execution of this TO. The Contractor shall perform all work in accordance with federal, state, and local statutes and regulations. The Scope of Work is to include the following: • All site demolition to sub grade as described on the Demolition Plan within the demolition area to include: o Asbestos abatement in the former antique mall o Demolition and/or Green Deconstruction of the antique mall (see bid options). o Demolition and or Green Deconstruction of building located in the northeast corner of the project site. o Demolition and/or Green Deconstruction of all asphalt and concrete to be recycled or disposed of off -site. o Demolition and or Green Deconstruction of existing foundation wall located to the west of the former antique mall. o Demolition and or Green Deconstruction of all curb and gutter located onsite not associated with surrounding properties or right of ways. o Demolition and removal of all utilities located on site within the limits of the demolition area except for the storm sewer running south to north through the site. o All utilities to be cut and capped at site boundary as described on Demolition Plan. o Removal of all bollards located on site not associated with adjacent properties. o Removal of all existing fencing onsite. • All permits (City and State Abatement, Demolition, Hydrant, etc. as needed) • Provide a Health and Safety Plan (HASP) for WESTON's approval. Contractor will also be required to follow WESTON's Health and Safety Protocol. • Mobilization. 44` and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 2 of 11 Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 -729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com • Schedule utility locate, cuts, and caps at the property line. • Asbestos abatement of existing antique mall as directed by the Asbestos Survey and Phase 1 Environmental Site Assessment and as well as directed by a licensed asbestos building inspector. • Immediately notify WESTON of any additional contaminated materials (i.e. soil) encountered. • Immediately notify Weston of any site conditions not accounted for in this SOW, the Demolition Plan, identified on the sitewalk, or in supporting documents. • Manifest and dispose of all contaminated waste in an environmentally responsible and accepted fashion. Provide copies of all disposal documentation to WESTON. • Provide certificate of acceptance by a licensed asbestos building inspector and necessary reports and documentation must be provided to WESTON. • Salvage any materials that may be reused by Habitat for Humanity, resold, or donated (as part of green deconstruction option). • Recycle any materials (i.e. steel, lumber, CMU, glass, etc.) that can be diverted from landfills. • Provide documentation of weight and type of materials taken to reuse, recyclers, or landfills. Include receipt or other means of verifying location and acceptance of material. • Make every effort to identify and recommend alternative means of disposal other than to a landfill. • Comply with WESTON's material tracking guidelines to document WESTON's effort for achieving LEED and tax credit/deduction goals. It is the intent for the contractor to maintain rights and proceeds from materials sold to recyclers or reuse facilities • After deconstruction of buildings to the point most economically feasible and acceptable to WESTON, wrecking the building with heavy equipment is acceptable. • Removal of any trees located onsite. • All materials suitable for crushing (i.e. foundations, slab on grade, CMU walls, brick, roof ballast) can be processed on site (Green Deconstruction option). • Backfill and compaction of the basement volume with materials in accordance with pending geotechnical specifications and potential Colorado Department of Public Health and Environment requirements. • All work is to be bonded. • Implement storm water BMPs as required by local jurisdictions prior to and during deconstruction and demolition. WESTON will require storm water BMPs to be maintained by contractor for a period of 1 year after site demolition is complete. • Provide onsite, office trailer, water, electric, and sanitary restrooms. • Dust control. • Traffic Control. • Groundwater pumping and discharge as permitted by local, state federal laws. • PPE. • Leave site in a graded, safe condition. 44` and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 3 of 11 SOLUTIONS Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com • Provide seeding for entire to site upon final site grading. • Coordination with WESTON's Site Manager who will be on site daily. The following are items that should be included in the Green Deconstruction option for this site: Requirement: Recycle, reuse, and/or salvage nonhazardous construction and demolition debris. So long as the material is diverted from a landfill, it is considered recycled, reused, and/or salvaged. Excavated soil and land clearing debris do not count towards LEED quantities, however it is still beneficial to recycled/reuse /salvage. A minimum of 75% of materials (as measured by weight) must be diverted from landfills to fulfill this requirement. Execution: Track the quantity of all materials demolished, either by volume or by weight. This can be accomplished via weigh tickets from the trash hauler /recycling company. Quantities need to be tracked consistently throughout (weight or volume). Materials may be crushed onsite and used as backfill as long as appropriate provided adequate emission controls are provided, and any waste is removed, and if it is approved by a geotechnical firm considering future site development requirements. • Concrete — curb and gutter, sidewalks, equipment pads, foundations, floors, walls, roof slabs, CMUs, etc. Send off -site for recycling or crush onsite and use as sub base material or backfill material. • Wood — wall framing, roof framing /sheathing, doors and frames, casework, etc. Send off -site for recycle; chip and mulch onsite. • Asphalt — parking lots, walks, etc. Send off -site for recycle or crush onsite and use as sub base material or backfill material. • Gypsum — Gypsum board. Send off -site for recycling. Gypsum can be composted. • Metals — structural support i.e. I- beams, floor /roof decking, etc.; fire suppression piping; Doors and frames; window frames; light ballasts; plumbing fixtures; drop ceiling tracks; etc. Send off -site for recycling. • Brick - exterior /interior brick cladding and walls, brick pavers /walkways, etc. Send off -site for recycling; can be crushed onsite and used as sub base or backfill material; can be reused on -site or sold for off -site reuse. 44"' and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 4 of 1 I Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 a www.westonsolutions.com • Glass — windows, storefronts, curtain walls, doors, mirrors, etc. Send offsite for recycling. Glass from light bulbs can be recycled, including fluorescent tubes, offsite or via a rentable light bulb crusher. • Plastics. • Carpet/Textiles — send offsite for recycle or reuse. • Cardboard — material packaging, etc. Sent off -site for recycling. • Building Insulation — Sent offsite for recycle. • Interior furnishings, equipment, electronics. • Plumbing fixtures — toilets, sinks, urinals, etc. Recycled off -site or reuse. • HVAC components. • Roofing materials — rock ballast. 2.0 APPLICABLE DOCUMENTS The Contractor shall identify and comply with all applicable federal, state, and local statutes and regulations including but not limited to; International Building Code (IBC); Unified Facility Criteria (UFC); National Fire Protection Association (NFPA); National Electrical Code (NEC) and including all changes and amendments in effect on the date of issuance of this TO. It is the Contractor's responsibility to identify and comply with all applicable requirements. The Contractor shall comply with the Demolition Plan provided by WESTON. 3.0 WESTON - FURNISHED INFORMATION, EQUIPMENT, AND PROPERTY WESTON furnished project Furniture, Fixtures, and Equipment (FF &E) will not be included in this contract. 4.0 MANAGEMENT, PLANNING, AND REPORTING REQUIREMENTS The Contractor shall implement a full range of construction and engineering activities as specified in this TO and in accordance with all applicable compliance documents. The 44' and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 5 of 11 W-Awm Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 Ulom www.westonsolutions.com Contractor shall supply all labor, equipment, and materials necessary to accomplish the work assigned unless otherwise specified in this TO. The Contractor shall perform management and planning functions, including performance measurement and fund status reporting, through the course of this effort. 4.1 Work Breakdown Structure (WBS) The Contractor shall prepare and submit, for approval, a VMS compatible with Construction Specifications Institute (CSI) format for construction activities. The VMS shall be used to report the schedule status for this project. All tasks required under this type of TO shall be included in the VMS. 4.2 Schedule and Planning Requirements The Contractor shall provide schedules for tracking work progress as specified in this TO. 4.2.1 Integrated Master Schedule (IMS) The Contractor shall prepare and submit an IMS for approval. The IMS shall detail the project schedule and status through the use of Gantt charts, and Critical Path Method (CPM) analyses. The project schedule shall be resource loaded and reported using the approved "S. The project schedule shall also comply with the Period of Performance outlined for this TO. 4.3 Cost and Status Reporting 4.3.2 Requirements for Firm Fixed Price TO. The Contractor shall provide a payment schedule. This document shall be submitted after notice to proceed along with other site plans, and updated and provided monthly by the Contractor to demonstrate progress on the project. These reports should be provided no later than the 22 of each month. 4.4 Meeting and Conference Requirements The Contractor shall perform a site visit and/or attend a pre - proposal conference, a preconstruction conference (kick -off meeting), red zone meetings, and /or other meetings necessary to support construction activities. The Contractor also shall attend and /or support weekly meetings and teleconferences to discuss technical or regulatory issues and project progress and status. 4.5 Notification Requirements 44 and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 6 of 11 Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 a k i T I NGA, www.westonsolutions.com The Contractor is required to notify the Project Manager of critical issues that may affect the contract performance and/or human health and the environment. On critical issues, verbal notification should be made immediately, followed by written notification as soon as practical. 4.6 Permits The Contractor shall develop, coordinate, apply for, and obtain all federal, state, local, and other applicable permits, access, agreements, licenses, and certificates required to perform and complete this TO. The Contractor shall maintain a library of these documents at the Contractor's site office as well as the corporate facility handling this TO. WESTON will be responsible for the acquiring the Storm Water Pollution Prevention Plan (SWPPP) The Contractor shall comply with all applicable permit conditions. The contractor will be responsible for maintaining BMPs for the duration of the project and for an additional period of one year. 4.7 Worksite Activities and Coordination 4.10.1 Coordination of Activities The Contractor shall coordinate worksite activities with all applicable personnel to ensure the protection of human health and the environment; the prevention of damage to property, utilities, materials, supplies, and equipment; and the avoidance of work interruptions. The Contractor shall provide physical security to work areas with security equipment and personnel as needed. The Contractor must comply with Occupational Safety and Health Administration (OSHA) safety and health regulations and local safety office requirements. The Contractor is required to provide the Project Manager copies of any OSHA report(s) submitted during the duration of this TO. 4.10.2 Hazardous Material and Hazardous Waste Activities. The Contractor shall handle the abatement, removal, and disposal of all hazardous materials and waste in accordance with applicable federal, state, and local requirements. The Contractor shall provide all hazardous materials use and hazardous waste disposal documentation to the Project Manager. The Contractor shall also comply with federal, state, and local requirements for any task involving the transportation of hazardous wastes and/or contaminated materials to off -site treatment, storage, and/or disposal facilities. This includes 40 CFR 260, 49 CFR 172, 173, 178, and 179, and all other applicable federal, state, and local transportation regulations. 5.0 PLANS, REPORTS, AND DELIVERABLES 5.1 Health and Safety Plan (HASP) The Contractor shall provide a Health and Safety Plan (HASP). 5.2 Technical Plans and Reports 40 and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 7 of I 1 Weston Solutions, Inc. 355 S Teller Street, Suite 300 �V�J1J Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com The Contractor shall provide technical plans, specifications, and reports as defined below. Some of these may include, but are not limited to, the following: 5.4.1 Construction Work Plan The Contractor shall prepare a Construction Work Plan that may include, but is not limited to, any or all of the following subsections. 1) Security 2) Excavation Plan 3) Spill and Discharge Control 4) Erosion Control 5) Emissions Control 6) Material and Equipment Control 7) Transportation 8) Traffic Control Plan 9) Site Analysis 10) Site Preparation 11) Demobilization and Closure 14) Explosive Safety 15) Hazardous Materials Management 16) Commissioning process 17) Utility Crossing Assessment 5.4.2 Technical Reports The Contractor shall prepare and submit the following technical reports as specified. a. Weekly Technical/Field Reports (Status Reports) b. Hazardous Materials Survey Report c. Hazardous Material and/or Hazardous Waste Disposal Report d. Shop Drawings and/or As -built Drawings 6.0 SITE WORK The Contractor shall perform site work as specified below. 44 and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 8 of 11 Weston Solutions, Inc. 355 S Teller Street, Suite 300 4111 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com 6.1 Conservation Activities shall be planned and implemented in a manner that protects existing site utilities, structures, surface features, service operations, monitoring and other types of wells, and the general site environment not included in the demolition. This includes the protection of trees, shrubs, and other vegetation not in the affected zone from dust damage, soil compaction, and physical contact with machines and equipment. If appropriate, the Contractor shall conserve uncontaminated topsoil by removal, storage, or redistribution. All reasonable measures shall be taken to minimize and suppress fugitive emissions of dust, vapors, and other site materials during site work. All fill materials shall be uncontaminated. The Contractor shall conduct all operations and activities with the intent of reducing the amount of pollution generated. Specific areas to be focused on are generation of solid waste, use of hazardous materials, use of ozone - depleting chemicals, generation of hazardous waste, and use of energy and water. The Contractor shall plan, construct, operate, maintain, optimize, and decommission systems necessary to control storm water run -on and runoff, and transport surface water drainage to a treatment plant, discharge location, or any other destination. 6.2 Site Preparation The Contractor shall perform site work as necessary to prepare sites for construction activities. Security and access controls shall be implemented to prevent unauthorized entry to sites and to protect wildlife from site exposure. WESTON will prepare the site by providing site fencing. Additional moving of fencing is the responsibility of the Contractor, and any damage repair is the responsibility of the Contractor. WESTON will shut off all utilities to be removed and /or cut and capped prior to the start of site work. 6.3 Demobilization The Contractor shall demobilize facilities as necessary, and restore the site. The Contractor shall remove any temporary facilities and implement erosion control measures such as seeding, mulching, sodding, and erosion control fabrics; restore roads, structures, and utilities that are not to be demolished. The Contractor will be responsible for maintenance of the site until final stabilization has been achieved plus 1 year of maintenance of BMPs beginning with final stabilization. 7.0 FACILITY CONSTRUCTION REQUIREMENTS The Contractor shall perform a full range of activities to meet all customers' engineering and construction requirements as described in this TO. 40 and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 9 of 11 � SOLUTIONS 7.4 Lump Sum Contract Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 - 729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com This contract will be completed for a firm -fixed lump sum price. 7.5 Other Construction Services 7 5.1 Inspections 7.5.1.1 Pre -Final Inspection. The Contractor shall conduct a pre -final walk through inspection and publish the pre -final inspection findings in a pre -final inspection report. 7.5.1.2 Final Inspection. The Contractor shall conduct a final inspection and publish the findings in a final inspection report in accordance with the format specified at the pre - construction conference and the RFP. The inspection shall concentrate on the items identified at the pre -final inspection and recorded in the pre -final inspection report. The final inspection report shall certify that all items of the design have been implemented and that the construction is complete. 7.6 Demolition The Contractor shall perform all demolition requirements to complete the project as required in this SOW and the Demolition Plan. This work shall include all demolition, removal, and disposal as defined in this TO. Demolition, removal, and disposal activities will be in conformance with local standards and regulations. The Contractor will be responsible for the transportation and disposal of any excess soil or base material generated during this project 7.7 Emergency Response The Contractor shall perform emergency response services. The Contractor can perform emergency repairs to facilities, systems, improvements, or utilities in the course of executing TO requirements. The Contractor shall perform emergency response to situations arising from natural disasters, project activities or actions from others to safeguard property and facilities the Contractor is responsible for. 7.8 Maintenance and Repair The Contractor shall be responsible for the repair of replacement of any site infrastructure not listed on the demolition plan requiring alteration or damaged during the completion of this project. 8.0 ENVIRONMENTAL 44' and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 10 of 1 I SOLUTIONS Weston Solutions, Inc. 355 S Teller Street, Suite 300 Lakewood, Colorado 80226 303 -729 -6100 • Fax: 303 - 729 -6101 www.westonsolutions.com The Contractor shall consult on environmental engineering problems incidental to construction efforts. The Contractor must be able to recognize when specialized environmental expertise is necessary and have the capability of providing that expertise. 9.0 POINTS OF CONTACT (POCs) WESTON POCs will be provided under separate cover. 44` and Wadsworth Redevelopment Site Demolition Exhibit 1 07 January 2011 Page 11 of 11 PRICING FORM FOR: DEMOLITION OF EXISTING BUILDINGS AND INFRASTRUCTURE AT 44TH AND WADSWORTH REDEVELOPMENT SITE COMPANY NAME: DATE: AUTHORIZED COMPANY REPRESENTATIVE SIGNATURE: BASE BID: Price Mobiilization: $0.00 Additional Mob, not included in cost: $ Asbestos Abatement of Existing Building: $0.00 Site Demolition: $0.00 Site Restoration and Maintenance of SW BMPS: $0.00 Bond: $0.00 Base Bid Total: $0.00 BID OPTION 1: Green Deconstruction of Site Green Deconstruction of Existing Buildings: $0.00 Green Deconstruction of Concrete and Asphalt: $0.00 Bond: 0 Bid Option 1 Total $0.00 TOTAL BASE BID + BID OPTION 1: $0.00 om _ C A N W N N N A 8 o cn o 0 o G d a a a m a a a a a n a a v a a a a n a d o v m m CD CD N r Q m N T -I (D y � rn 0 a S N Vl D o N 3 O D) = v c n p 7 n C1 O a O C p n 9 j m O O d D 5 r m m CD N 'O p '^ cn c a a m n N' 0 0 N v » o` (D = O C� m N o 3 a p' 3 rn S m 7 D 3 d (D p O J m m > a 3 ry' N O 0 d o n w O (n co - m n o o Z 3 m a (n --1 O a N CD y 3 N N < C < < G S G C T 1 M. S C O CL T l0 C N' 3 (D m S C C J O 7 O j N a ' N a N N d C '' C ' d N T ?1 ' r �. to ,Z m v w m C N W N N N A 8 o cn o 0 o G d a a a a a a a a a n a a n a a a a n a d o m m m m d m m m m m m m m m m d m m m d m m (n S O K 3 N N < C < < G S G C T 1 M. S C T l0 C N' 3 (D m S C C J O 7 O j N a ' N a d d C '' C ' d N T ?1 ' r �. to ,Z m 3 d C C Q N N N d C N C C G 3 m c N O a S a m N N N n O S a p c m CL (D n m m 0 0 m m � m m m w n d m < m m o o CD m N O N m 3 CD N CD T j cn (n L d 3� J 41 41 (n L G � 1 � � W L J ! � W r � T N � (n L d 0,4 RENEWAL WHEAT RIDGE Progress Through Partnership TO: Renewal Wheat Ridge Board Members FROM: Patrick Goff, Executive Director RE: Zone Change — RV America (11808 W. 44 Ave) DATE: January 13, 2011 The Community Development Department has received the attached request for approval of a zone change from Commercial -One and Commercial -One with use conditions to Mixed Use — Commercial Interstate and Mixed Use — Neighborhood for property located at 11808 W. 44 Avenue. The City's Zoning and Development Code requires the review by Renewal Wheat Ridge (RWR) of land use applications in an urban renewal area. The Code requires a recommendation from RWR based on its review of the application "against the provisions of the urban renewal plan with respect to the land area, land use, design, building requirements, timing and procedure." You are not making a recommendation on whether the request should be approved or not. Your task is to determine if the request is in compliance with the West 44 Avenue Ward Road Redevelopment Plan. Your finding will be one factor to be considered in the approval process. West 44 Avenue and Ward Road Redevelopment Plan The recommended West 44 Avenue and Ward Road development concept is a community commercial center that serves residents and non - residents, and also includes a mix of commercial, office and municipal sales tax generating retail uses. Development along the edges of the Plan Area will be used to buffer the commercial area from the adjacent residential neighborhoods. This location serves as the western entrance to Wheat Ridge. A mix of commercial uses and an inviting streetscape should provide a sense of arrival into Wheat Ridge. The accompanying Land Use Concept Plan adopted as part of the Urban Renewal Plan establishes the recommended uses for West 44 Avenue and Ward Road. The property in question is proposed as Community Commercial and Residential. The Plan encourages the redevelopment of sites to maximize utilization of the land and to provide flexibility for different development opportunities. All development south of West 44 Avenue adjacent to Tabor Lake should incorporate pedestrian amenities allowing use and enjoyment of the adjacent open space. The property is adjacent to proposed uses of office, traditional residential and open space. Recommended Findings: The Land Use Concept Plan recommends that the subject property be considered for Community Commercial and Residential and to provide flexibility for different development opportunities. The zone change request is to Mixed Use — Commercial Interstate and Mixed Use — Neighborhood. Staff finds that the requested zone change is in conformance with the West 44` Avenue and Ward Road Redevelopment Plan. The permitted uses in these zone districts will provide for that flexibility for different development opportunities that are encouraged in the West 44 Avenue and Ward Road Redevelopment Plan. Attachments: 1. Community Development Referral Form 2. West 44 Avenue Ward Road Redevelopment Plan Land Use Concept Plan C,tV of W heatl�dge lCo &imuwr Y DEVELOPMENT ommwnitt, Develop near•: 7500 7.9th Avenue '­'heat Ridge, Colorado 80033 303. 135. 1843 Fax: 303.235. 1857 Community Development Referral For:y: Date: December 8, 2010 Response Due: December 22, 2010 The Wheat Ridge Community Development Department has received a request for approval of a zone change from Commercial -One and Commercial -One with use conditions to Mixed Use - Commercial Interstate and Mixed Use - Neighborhood for property located at 11808 W. 44 Avenue. See attached map delineating the proposed zoning line. No response from you will constitute having no objections or concerns regarding this proposal. Case iJo.: WZ- 10- 09 /Sach (RV America) Request: Approval of a change of zoning to Mixed Use - Commercial Interstate and Mixed Use Neighborhood to allow future development of the property in accordance with the City's mixed use zone districts. The intent of the line separating the two zone districts on the property would be to have the less intensive zone district (Mixed Use - Neighborhood) adjacent to the existing low density residential neighborhood to the south and east. The more intensive zone district (Mixed Use - Commercial Interstate) would be oriented toward W. 44 Avenue and the new 1 -70 on and off ramps. The property is 3.5 acres in size. See attached the attached sheets about the MU -C Interstate and viU -i4 zone districts for information on use allowances and development standards. The zone change is the first step of the process. If approved and prior to construction of any new structures, a site development plan and subdivision plat approval v-111 be required. Please inform the case manager of any concerns about the site's ability for future development based on the proposed zoning. At the time of site plan revievi, vihen a specific development proposal is available, an additional referral regarding utility needs for the proposed de-elopment gill be issued. Case r,ianager: Meredith Reckert Voice: 303.235.2848 Fax: 303.235.2857 Email: mreckert &i.wheatridge.co.us ' Carnation City" DISTRIBUTIOiM: t "later District (Valley) Sanitation District (Fruitdale) Fire District (Arvada) Colorado Department of Transportation AT&T Broadband Xcel Energy Qwest Communications Vicinity map :;!heat Ridge Public 4Norks Wheat Ridge Economic Development Wheat Ridge Police Department Wheat Ridge Building Division Wheat Ridge Urban Renewal Autho;+ty y. ..aev�vw.•w /) ' T r i . - _ W r ► ped 111�4-1 Interstat r� : Vicinity map :;!heat Ridge Public 4Norks Wheat Ridge Economic Development Wheat Ridge Police Department Wheat Ridge Building Division Wheat Ridge Urban Renewal Autho;+ty P F t �7 "The Cernation City " r f w . 2 y. ..aev�vw.•w /) 44th AVE - --- _ . - _ W n - ► ped 111�4-1 Interstat P F t �7 "The Cernation City " r f w . 2 iv'IXEO USE NF1GH80RHOOD ( 0 IMIXED U5': IONFDISTRICT atRQS!ge dETTERLONING FOR A VIBRANT W14EATRIDGF DISTRICT INTENT: intended for neighborh ado s l ery ng c dommehciallanrd retail uses, as medium density mixed use development. I well as residential and civic land uses. BUILDING HEIGHT 35' All other Dununl • Building height limits match City Charter height restrictions SETBACKS AND BUILD -TO REQUIREMENTS Minimum Rear Setback 1 -2 story building =10' Side and rear setback where abutting 3 story building =15' single- or two - family residential 4 sto building or hi her = Setback = required minimum distance between a building and the nearest property line Primary Street Frontage Build -to Area = 0' - 12' Secondary Street Frontage At least 60% of the build -to area At least 30% of the build -to area Build -to Area = 0' - 12" d area along the street /sidewalk that must be filled Build -to Area = require with a building (see image to right) Build -To Requirements °t yodd � e tfrOrta9e .� � Primary 5 e 60% °t b Primary street Frontage AUTO - ORIENTED USES uiremen s. Drive -Up and Drive -Thru Uses Allowed as a Conditional Use with separation req Fast food drive-thrus must be located at fast food drive least 500 ft apart from th u Other drive -thru uses, such as a coffee shop or bank, must be located at least 500 ft from one another. Note: separation requirements do not apply to drive -thru uses in lace Drior to MU -N zonin . Allowed as a Conditional Use. No overni ht outdoor stora e. Car Re air Outdoor sales lots not allowed. Allowed as a Conditional Use Car Sales with indoor showrooms Allowed as a Conditional Use with separation requirements. Gas Stations Must be at least 1,000 ft from another gas station. Note: separation requirements do not apply to gas stations in Design Requirements for Drive -Thrus and Drive -Ups: lane. Drive -up lanes visible from the street must be screened by a screen Maximum number of 1 drive -up buffer wall, at least 42 tall, and a 4' wide landscape Drive -up window shall be at the side or rear of the building and not facing a street corner ° I MIXED USE , N T1 tRkd BETTER ZONING FOR A VIBRANT WHEAT RIOGF RESIDENTIAL TRANSITIONS MIXED USE NEIGHBORHOUD (MU -M) 70NF UISTRIC'I Requirements for New Development Adjacent to Residential Uses Landscape Buffers and 6' buffer, in combination with 6' Screen Walls screen wall or fence, required for surface parking lots and drive - thrus that are adjacent to a residentially -zoned lot Setbacks /Landscape Buffers 1 -2 story building = 10' (side and rear where adjacent to 3 story building = 15' single- or two - family residential) 4 story building or higher = 20' Upper -Story Stepbacks 5' stepback per story for stories (where adjacent to single- or two- 2.4 (see image to right) family residential) Residential Transition: Upper Story Stepbacks » 5 f 35" OPEN SPACE REQUIREMENTS Minimum Open Space Requirements Mixed use development 10% of development site iin le use development 15% of develo ment site � -Nat-= lilt - UUCa PIdIILt!U areas as wen as narascapecl areas, such as a plaza Green roofs may count toward open space requirements DEVELOPMENT REVIEW All sites are subject to administr .,ve , view--:,, ­ . he site plan review pro- wu public hearings are required for developme - review. Sites o­-, 10 acr, ­ ,;_ or that have more than one phase of development, must submit a concept plan prior to site plan review. Sites over 10 acres require a neighborhood meeting prior to submittal of the concept plan Conditional Uses must go through an administrative review to meet specific criteria related to the impacts of that use. MIXED USE MIXED USE COmIVIERCIAL INTERSTATE MZ g C BETTER ZONING FOR A VIBRANT WHEAT RIDGE (MU -C INTERSTATE) :,Uf3- DISiRICI DISTRICT INTENT: for properties that are within 500 feet of Interstate -70 and that are located on a commercial corridor with direct access to Interstate -70. Generally follows the Mixed Use - Commercial district, allowing for a wide range of uses and high- density development, but is intended for highway adjacent sites that may require variation in design or land use due to direct proximity to the interstate. BUILDING HEIGHT Minimum Height - Any Building 20' Maximum Height - Mixed Use Building 8 stories 118' Maximum Height - Single Use Building 6 stories 90' • Whatever is more restrictive, maximum nelgnt or maxlmurrf Teel, dNN IICJ • 4 -story height limit for any portion of a building within 100 feet of single - or two - family residential • For buildings over 75' tall, a 10' stepback is required for any facade that faces a public street or open space (see image to right) cUTRArkm AND RHILD -TO REQUIREMENTS SETBACKS Minimum Side Setback 0' 5' Minimum Rear Setback Side and rear setback where abutting 1 -2 story building = 10' single- or two - family residential 3 story building =15' with indoor showrooms. 4 sto building or higher = 20' Setback = required minimum distance between a OullUillg dI1U 1110 IICGIca property line BUILD -TO AREAS Primary Street Frontage At least 50% of the build -to area Build -to Area = 0' - 20' must contain building facade Secondary Street Frontage At least 30°x6 of the build -to area Build -to Area = 0' - 20' must contain building facade Build -to Area = required area along the street /slaewaiK tnat must oe IIIICu with a building (see image to right) rrr� w wtr� tlunI FKTDIAI I KIN Upper Story Stepbacks I I Build -To Requirements r' t« 11G ` prlman SAre e i p — Bu4d -TOArea - 1 - --_- Stl%of hu0d -to area Primary Street Frontage Design Requirements for Drive -Thrus and unve -ups: Drive -up lanes visible from the street must be screened by a screen wall, at least 42" tall, and a 4' wide landscape buffer Drive -up window shall be at the side or rear of the building and not facing a street corner Allowed as a Conditional Use. Drive-Up and Drive -Thru Uses Allowed as a Conditional Use. No overnight outdoor sto e. Car Re air I Outdoor sales lots not allowed. Allowed as a Conditional Use Car Sales with indoor showrooms. Allowed as a Conditional Use. Gas Stations Office- warehouse, restricted light Allowed as a Conditional Use. No outdoor storage allowed. industrial uses and wholesale Design Requirements for Drive -Thrus and unve -ups: Drive -up lanes visible from the street must be screened by a screen wall, at least 42" tall, and a 4' wide landscape buffer Drive -up window shall be at the side or rear of the building and not facing a street corner MIXED USE Wheat (2e BETTER ZONING FOR A VIBRANT WHEAT RIDGE MIXED USE COMMERCIAL INTERSTATE (MU -C INTERSTATE ) ,ew_i RESIDENTIAL TRANSITIONS Requirements for New Development Adjacent to Residential Uses Landscape Buffers and 6' buffer, in combination with 6' Screen Walls screen wall or fence, required for surface parking lots and drive - thrus that are adjacent to a residentially -zoned lot Setbacks /Landscape Buffers 1 -2 story building = 10' (side and rear where adjacent to 3 story building =15' single- or two - family residential) 4 story building or higher = 20' Upper -Story Stepbacks S' stepback per story for stories (where adjacent to single- or two- 2 -4 (see image to right) family residential) OPEN SPACE REQUIREMENTS Residential Transition: Upper Story Stepbacks 5 5 j35' Minimum Open Space Re uirements Mixed use development 10% of development site Single use development _ 15% of development site Open space includes planted areas as well as hardscaped areas, such as a plaza Green roofs may count toward open space requirements DEVELOPMENT REVIEW All sites are subject to administrative review only, through the site plan review process. No public hearings are required for development review. • Sites over 10 acres in size, or that have more than one phase of development, must submit a concept plan prior to site plan review. Sites over 10 acres require a neighborhood meeting prior to submittal of the concept plan • Conditional Uses must go through an administrative review to meet specific criteria related to the impacts of that use. City of / ) " heat 1�gc, W MMUNHY DLVLL0PM1Nr ML.ed Use - --one Districts Permitted Uses Sec. 26 -1111. Permitted Uses A. Principle: the mixed use zone districts emphasize building form, rather than permitted uses. A range of uses is permitted to promote mixed use development. B. Permitted and special uses are shown in the following table. This table, and not the table in section 26 -204, shall apply for all of the mixed use zone districts. Uses not listed shall be deemed excluded. 1. The Community Development Director has the authority to determine that a use not specifically listed should be so permitted or allowed on the basis of it being similar to a listed use, compatible in character and impact with uses in the zone district, consistent with the intent of the district, and which would not be objectionable to nearby property by reason of odor, dust, fumes, gas, noise, radiation, heat, glare, vibration, traffic generation, parking needs, outdoor storage or use, or is not hazardous to the health and safety of surrounding areas through danger of fire or explosion. The Director's decision may be appealed to the Board of Adjustment as an interpretation request. Permitted Uses MU -C MU -C TOD MU -N Use Group MU -C Interstate Assisted living facility P P P P Dwelling, single detached NP NP NP P Dwelling, single attached P P P P Dwelling, duplex P NP NP P Dwelling, multiple P P P P Dwelling, live /work P P P P Foster care home NP NP NP P Residential group home P P P P Public, Civic, and Institutional Community buildings and cultural facilities, including P P p P libraries, museums, and art galleries C C C NP Hospital H Parks, open space, P p P P playgrounds, and plazas P Place of worship P P P Public uses and buildings P P P P Recreation facilities, indoor P P P P Permitted Uses Use Group P U -C MU -C MU -C TOD MU -N Interstate and outdoor Schools, public and private; colleges, universities, and P P P P trade schools Utilities, major NP NP NP NP Utilities, minor P P P P Transit stations, public or private C C C C Commercial Services and Retail Adult entertainment NP NP NP NP Animal daycare, indoor with no outdoor runs or pens P P P P Bail bonds (per §26 -634) C C NP NP Banks and financial institutions, no drive - through or P P P P drive -up Banks and financial institutions, with drive - through C P C C or drive -up Bars, taverns, and night clubs P P P P Bed and breakfast P P P P Car washes NP C NP NP Day care center, child and adult P P P P Drive -up or drive - through uses (per §26 -1106. E) C P C C Eating establishment, sit down P P P P Eating establishment, drive- through or drive -up C P C C Fast food eating establishment, drive - through or drive -up C P C C Motor fueling stations C C NP C Motor vehicles sales, outdoor display NP NP NP NP Motor vehicle sales, indoor display P P C C Outdoor storage NP NP NP NP Pawn brokers NP NP NP NP Personal services P P P P Permitted Uses Use Group MU -C MU -C Interstate MU -C TOD MU -N Photocopying and printing P P P P Recreation facilities, P p P P commercial Repair, rental and servicing of automobiles, no outdoor C P C C storage Retail sales — up to 20,000 gsf P P P P for one tenant space Retail sales — up to 60,000 gsf P P C C for one tenant space Retail sales — over 60,000 gsf C C NP NP for one tenant space Veterinary clinics and hospitals, no outdoor runs or P P P P pens Hospitality and Entertainment Art studios and galleries P P P P Hotels, motels, and extended P P P P stay lodging Studios, including art, music, dance, television and radio P P P P broadcasting stations Theaters P P P P Office and Industrial Medical and dental clinics P P P P Offices P P P P Office- warehouse, no outdoor C C C NP storage NP NP NP NP Outdoor storage C C NP Restricted light industrial C Wholesale C C C C Ancillary Uses P Parking facilities P P P Temporary Uses Special events, including P P P P festivals and farmers markets _ - , � � nip c nc -1 -7\ N = nt Permitted Key: P = Permitted c = Conaitionai use �Seu y 1 1 1 • , C. Separation requirements for drive - through /drive -up uses: Where drive - through and drive - up uses are permitted in the Permitted Use Table (section 26- 1111.13) the following 3 separation requirements shall apply. These separation requirements shall not apply in the MU -C Interstate Sub - district and shall not apply to any mixed use development that has an approved concept plan (per section 26- 1116). 1. There shall be a minimum 500 foot separation between fast food eating establishments with a drive - through, measured radially from any fast food drive - through use, including existing uses, regardless of zone district. 2. There shall be a minimum 500 foot separation between all other drive - through /drive -up uses, including pharmacies, banks, and non -fast food eating establishments with a drive -up window, measured radially from any drive - through /drive -up use, including existing uses, regardless of zone district. 3. Minimum separation requirements shall only apply to properties that did not have a legal, operating drive - through /drive -up use at the time of rezoning to a mixed use zone district. D. Separation requirements for motor fueling stations: Where motor fueling stations are permitted in the Permitted Use Table (section 26- 1111.6), the following separation requirements shall apply. These separation requirements shall not apply in the MU -C Interstate Sub - district and shall not apply to any mixed use development that has an approved concept plan (per section 26- 1116). 1. There shall be a minimum 1000 foot separation between motor fueling stations, measured radially from any motor fueling station, including existing uses, regardless of zone district. 2. Minimum separation requirements shall only apply to properties that did not have a legal, operating fueling station use at the time of rezoning to a mixed use zone district. 4 l t\% a a a%\ a a a a a a a a a a a a a a% a a a a a a a a a a a a a a a 3 m ° a m 3 .1 p m �\ a m m \ \\ m m co C m fD a m 0 y Q H � n 3 D e�aSt Dc1 (D m w U) � n D) 1 CD 7 I ,7200 121_4 422, -15 4316 4386 4373 138 4193 _ 1710 , 4318 4327 4a90 4388 I 1 I I 17500 4373 143 id290 12470 1 17410 e<., 17400 ,2380 4236 ffi7S 420. 4785 4346 43i5 4.905 4385 Vivian St. 200 1 4270 4280 4320 4830 4310 4360 1E 1 S N M Ward Rd. 1 / I 1 C D M w I 4= :M Proposed 1 -70 On/Off Ramp I I v • „607 A „ae6 ism . 4815 48'6 4806 4816 006,. 4785 4ah _4883 40P 416 0046 4070 ,686 48,6 4035 _4 08]6 on V 4775 4800 � 4604 4624 4844 4684 4e64 4P4 \ Q 0,,4RE N EWAL WHEAT RIDGE Progress Through Partnership MEMORANDUM TO: Renewal Wheat Ridge Board FROM: Patrick Goff, Executive Director DATE: January 12, 2011 SUBJECT: Resolution Designating a Public Place for the Posting of Notices of Public Meetings Pursuant to legislative amendments to the Colorado Open Meeting Law as Section 24-6 - 402(2)(c), the Urban Renewal Authority is to annually designate at its first meeting for each calendar year a public place for the posting of notices for meeting. By properly designating a place for posting meeting notices, a public entity will be deemed to have given full and timely notice of any meeting so long as notice thereof was posted at the designated place at least twenty -four hours in advance thereof. Attached is Resolution 01, Series of 2010, which identifies the lobby of the Municipal Building as the designated place for posting of meeting notices. Attachment 1. Resolution 01 -2011 WHEAT RIDGE URBAN RENEWAL AUTHORITY RESOLUTION NO. 01-2011 TITLE: A RESOLUTION ESTABLISHING A DESIGNATED PUBLIC PLACE FOR THE POSTING OF MEETING NOTICES AS REQUIRED BY THE COLORADO OPEN MEETINGS LAW BE IT RESOLVED BY WHEAT RIDGE URBAN RENEWAL AUTHORITY, THAT: Section 1 . The lobby of the Municipal Building shall constitute the designated public place for the posting of meeting notices as required by the Colorado Open Meetings Law. The Executive Director or designee shall be responsible for posting the required notices no later than twenty -four (24) hours prior to the holding of the meeting. All meeting notices shall include specific agenda information, where possible. DATED this day of , 2011. Rick Adams, Chair ATTEST: Ann Lazzeri, Secretary APPROVED AS TO FORM: Corey Hoffmann, WRURA Attorney RE N EWAL Progress Through Partnership MEMORANDUM TO: Urban Renewal Authority Board Members FROM: Patrick Goff, Executive Director RE: Resolution 02 -2011 Supplemental Budget Appropriation DATE: January 13, 2011 Attached is a resolution adopting a supplemental budget appropriation for the 2010 Wheat Ridge Cyclery Fund budget. A supplemental budget appropriation in the total amount of $4,638.75 is necessary for the following expenditure: Wheat Ridge Cyclery Fund The WRURA and Wheat Ridge Cyclery entered into an Improvements Agreement on March 20, 2007 for improvements to the Cyclery property located at 7085 W. 38` Avenue. It was the WRURA's desire to assist the Cyclery in making a number of improvements to the property, which would improve the public appearance of the property, remedy its deterioration, maintain a positive business environment in the neighborhood, and serve as an anchor to attract other desirable businesses to the neighborhood. As an inducement to the Cyclery to complete certain improvements, WRURA agreed to reimburse to the Cyclery those costs associated with these improvements by implementing tax increment financing. Under the Agreement, the Cyclery will be receiving 100% of the sales and property tax incremental revenue generated by the expansion of the business up to a maximum amount of $264,180 or 10 years, which ever comes first. The outstanding balance after the 2010 payment is $163,489 or 7 years. The total sales and property tax increment for 2010 is $44,638.75. However, only $40,000 was projected and budgeted in the 2010 budget. Therefore, a supplemental budget appropriation in the amount of $4,638.75 is required to balance the budget. Recommended Motion: "I move to approve Resolution 02 -2011, amending the fiscal year 2010 Urban Renewal Budget to reflect the approval of a supplemental budget appropriation in the amount of $4,638.75 for purposes of the sales tax increment payment to Wheat Ridge Cyclery." Attachments: 1. Resolution 02 -2011 - -_- __. . _...ti . _.. _.. ____ �. _ _ -_ _ __ - -_- - -- -- -_ WHEAT RIDGE URBAN RENEWAL AUTHORITY RESOLUTION NO. 02 Series of 2011 TITLE: A RESOLUTION AMENDING THE FISCAL YEAR 2010 URBAN RENEWAL BUDGET TO REFLECT THE APPROVAL OF A SUPPLEMENTAL BUDGET APPROPRIATION IN THE AMOUNT OF $4,638.75 FOR PURPOSES OF THE SALES TAX INCREMENT PAYMENT TO WHEAT RIDGE CYCLERY WHEREAS, C.R.S. 29 -1 -103 (1) of the Local Government Budget Law of Colorado requires certain local governmental entities to prepare and adopt an annual budget; and WHEREAS, the Attorney for the Authority has opined that the provisions of the Budget Law do apply to the Authority; and WHEREAS, notice of adoption of the 2010 supplemental appropriation was given by the Urban Renewal Authority in compliance with C.R.S. 29 -1 -106; and WHEREAS, the Authority previously adopted an appropriation for 2010 on December 1, 2009, which appropriation must be modified for the sales tax increment payment to Wheat Ridge Cyclery; and WHEREAS, in compliance with the provisions of the Budget Law regarding notice, objections, and hearing, a public hearing was held on the Supplemental Budget and Appropriation for 2010 on January 18, 2011. THEREFORE, BE IT RESOLVED by the Wheat Ridge Urban Renewal Authority as follows: Section 1 . The year 2010 supplemental appropriation for the Wheat Ridge Cyclery Fund as shown on Exhibit 1 attached hereto is hereby approved. The purpose of the 2010 supplemental appropriation is to increase funds in line item 37- 122 - 800 -872 by $4,638.75 for purposes of the sales tax increment payment to Wheat Ridge Cyclery. Section 2 . Total expenditures of the Authority do not exceed available revenues and beginning fund balance. Section 3 . A certified copy of this resolution shall be filed with the Division of Local Government. ADOPTED the 18th day of January, 2011. WHEAT RIDGE URBAN RENEWAL AUTHORITY ATTEST: Chairperson Secretary to the Authority EXHIBIT 1 WHEAT RIDGE URBAN RENEWAL AUTHORITY Wheat Ridge Cyclery Project Fund 2009 Adjusted 2009 Estimate 2010 Adopted 2010 Amended BEGINNING FUND BALANCE $ - $ - $ - $ Revenues 37- 580 -00 -501 Property Tax Increment $ 15,000 $ 14,488 $ 20,000 $ 14,159 37- 580 -00 -584 Sales Tax Increment $ 15,000 $ 15,000 $ 20,000 $ 30,480 37- 580 -00 -581 Interest $ - $ - $ - $ - 37- 580 -02 -588 Sale of Property $ - $ - $ - $ _ 37- 122 - 700 -758 City Reimbursement y * °.. � l.�� S n�p a � ei R: Services 37- 122 - 700 -702 Conference & Meetings $ - $ - $ - $ - 37- 122 - 700 -706 Dues, Books, Sub $ - $ - $ - $ - 37- 122 - 700 -740 Mileage $ - $ - $ - $ _ 37- 122 - 700 -750 Professional Services $ - $ - $ - $ - 37- 122 - 700 -758 City Reimbursement $ - $ - $ - $ - 37- 122 - 700 -799 Misc. $ - $ - $ - $ _ Eb ��hi � sYY: � � .� �'� x�, ����.��i �'.`"�f k q5 t'+'+•5 � ti' � g - "Y'yi` {�.,. Es ... �� ���,` �x�..: ✓ „�,�,.a�',ey�GZ,..,,.._ E .,. s..x`= 1 a�«�,.". . '. .. .ran .+i .. Capital 37- 122 - 800 -801 Acquisition & Relocate $ - $ - $ - $ - 37- 122 - 800 -872 Site Improvements $ 30,000 $ 29,488 $ 40,000 $ 44,639 37- 122 - 900 -901 Loan Payment $ - $ - $ - $ -