HomeMy WebLinkAbout11433 W I-70 Frontage Road NINSPECTION RECORD OccupancvlTVpe °'INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Stemwall / (CEG) Concrete Encased Ground 0 Reinforcing or Monolithic W1 A/0 Weatherproof / French Drain Sewer Service Lines Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. CONCRETE SLAB FLOOR Electrical Heating (Underground) - - ------------------ -- - - -- ROUGHS Sheathing f Lath /Wall tie Mid -Roof 0 Electrical Service W1 A/0 Rough Electric Rough Plumbing Gas Piping INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Rough Mechanical "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. RIVR IV YRVI.CLVIRU Framing Insulation Drywall Screw FINALS Electrical f Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER .. r CITY OF WHEAT RIDGE `r0 000o r Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office - (303) 237 -8929 Fax INSPECTION NOTICE 10 �r Inspection Type ~� Job Address // 4 1f 3r A), ] M Permit Number 111�e,4 1/ s ❑ No one available for inspection:-- Time AM /PM Re- Inspection required: Yes! No N "When corrections have been made, caly /f/ �) i . spe at 303 - 234 -5933 Date: Inspector: DO NOT REMOVE MIS NOTICE s INSPECTION RECORD Occupancyrrype 'T - INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Stemwall / (EEG) Concrete Encased Ground ► - Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Water Service Lines INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ROUGHS Sheathing - Lath /Wall tie Mid -Roof ► - Electrical Service Rough Electric Rough Plumbing Gas Piping INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Rough Mechanical * * NOTE. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. 1 V 1'RV IiCC V IIY V Framing Insulation Drywall Screw - FINALS Electrical - Plumbing Mechanical Roof Building Final Fire Department R.O. W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. Parking & Landscaping * * NOTE. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER T CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office * (303) 237- 8929 Fax INSPECTION NOTICE I Inspection Type Job Address >1 a.� ✓rte y -7o �cyr x?G• 7w Permit Number /&L'.' ❑ No one available for inspection: Time AMtE M,3 Re- Inspection required: Yes_ When corrections have been made, call for re- inspection at 303 - 2345933 Date: a` Ll/ r l_ Inspecto � r s DO NOT REMOVE THIS NOTICE ♦��4' City of Wheat Ridge Commercial Plumbing PERMIT 110676 PERMIT NO: 110676 ISSUED: 06/14/2011 JOB ADDRESS: 11433 W. I -70 Fr. Rd. North EXPIRES: 06/13/2012 DESCRIPTION: 1 gas line from new meter location to 125k heater * ** CONTACTS * ** owner 303/342 -3970 Six Oaks Limited sub 303/654 -1301 Elmer Johann Jr. 02 -2111 Crestview Plumbing ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: UA USE: UA BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 1,500.00 FEES Permit Fee 60.50 a Total Valuation .00 Use Tax 27.00 ** TOTAL ** 87.50 _ 4 Conditions: Subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this doc ment and/ rts' companying pproved plans and specifications. Signature o WNER or CO CTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature it ding Offical Date INSPEC- N QUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUE ST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. I I City of Wheat ' �jdge COMMUNITY DEVELOPMENT , Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application Pro Property Owner 1plez Mailing Address: (if different than property address) Address: City, State, Zip: Date: Plan # Permit # I et_i 11-/k eat l Contractors City License M Phone: SulYon trastcrs Electrical: Plumbing: Mechanical: City License # City License # City License .................. 011im wor &IOU f Contract Value: Y $ 4 Review Fee (due at time of submittal): Squares BTU's .Z Gallons Amps Sq Ft. $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE. (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: 1Z //n 4h SIGNATURFe� DATE: jj Bldg Valuation: �• ' City of Wheat Ridge 1� Commercial Electric PERMIT - 110664 PERMIT NO: 110664 ISSUED: 06/10/2011 JOB ADDRESS: 11433 W. I -70 Fr. Rd. North EXPIRES: 06/09/2012 DESCRIPTION: Install new 100 amp service- lateral service connect 6 120v * ** CONTACTS * ** owner Six Oaks Limited Par sub 303/202 -5030 PAUL PARSONS 02 -0650 KELLY ELECTRICAL SERVICES INC ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: UA BLOCK /LOT##: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 3,100.00 FEES - Permit Fee 109.20 Total Valuation .00 Use Tax 55.80 ** TOTAL ** 165.00 Conditions: Must comply w/ 2006 IBC & 2005 NEC. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform . the work described and approved in c ,unction with this permit. I further attest that I am legally authorized to include all entities named within this document parties to the work to be performed and that all work to be performed is disclosed in this document and /or its' acgcWpany' g approved plansand'specificatiyhs. Signature of , or CONTRACTOR (Circle one) \ 1 Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provi 'on liany applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to fi on. Signatu of (?fiief Building O£fical Date i INSPECTION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. W- City of Wheat Jd Date: COMMUNITY DEVELOPMENT Plan # Building & Inspection Services Division Permit # D� 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303- 234 -5933 Building Permit Application Rioj erty Address_! (� �"yj 14, Tr -T(> p eA tA. Property Owner (please print): �K e, (&MU<i ,p Phi Mailing Address: (if different than property address) Address: City, State, Zip Col tj*M: Contractors o�n - tray / Flartncal City License # .icense #: O a O (05 }( P Plumbing: City License # �aC) c Qc'J — d Mechanical: City License # tj Descr%ptlo"f wdrk ' ni t � Q - tr � Contract Value ��� • �S�C��tititiV $ iJCl. r t'n,vC�J �,tt��•�la� c�� � � h �SeJI�z�Ge•� -Q. ��� `�� Review Fee (due at time of submittal): Squares BTU's Gallons Amps Sq Ft. $ — OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by ad] conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: — (OWNER) ONTRACTOR _ (AUTHORIZED REPRESENTATIVE) of (O ER) (CONTRACTOR) PRINT NAME: - 1 10— � t\ `�� SIGNATURE: s"^' If> Zel <FIRE DEPARTNIEN7 ❑ a IOVed W/ comments p dlSa roved, O''' � � � Ap pP r�eview'requned Bldg Valuation $ PANEL NEW 120/_ 0 2 8 VOLTS, 3 PHASE, _ 4 WIRES, SN, 1 AMP BUS, 100 — AMP MAIN BREAKER _ 10,000 A.I.C. RATING (MINIMUM), NEMA Ni ENCLOSURE, SURFACE MOUNTED MFG CH OR EQUAL, TYPE PLUG —IN DESCRIPTION WIRE AMP POLE CKT VA f VA ICKT POLE AMP WIRE DESCRIPTION EXIST LIGHTING 12 VOLTAMPS 20 1 1 1060 A 1176 2 1 20 #12 2.352 EXIST MICRO Sc FRIG EXIST HVAC #12 X 1.25 = 20 1 3 1176 B 720 4 1 20 12 ' EXIST CONV RCPTS EXIST AIR COMP #12 20 1 5 1200 A 6 1 20 #12 SPARE 7 B 8 9 A 10 11 B 12 13 A 14 15 B 17 A 18 19 B 20 21 A 22 23 8 24 PHASE A = 2 ,236 VOLTAMPS PHASE B = 1,896 VOLTAMPS PHASE C 1,200 VOLTAMPS PANEL LOAD CALCULATIONS: (INCLUDES MODULAR BUILDING LIGHTING 1.060 VOLTAMPS X 1.25 = 1 VOLTAMPS RECEPTACLES - -1ST 10KVA 720 VOLTAMPS X 1.00 = 720 VOLTAMPS RECEPTACLES -- BALANCE BE VOLTAMPS X 0.50 = VOLTAMPS LARGEST MOTOR LOAD 1.200 VOLTAMPS X 1.25 = 1,500 VOLTAMPS BALANCE OF MOTOR LOADS 2,352 VOLTAMPS X 1.00 = 2.352 VOLTAMPS KITCHEN EQUIPMENT VOLTAMPS X 1.25 = - VOLTAMPS ELECTRIC HEATING EQUIP VOLTAMPS X 1.00 = VOLTAMPS MISCELLANEOUS LOADS VOLTAMPS X 1.00 = VOLTAMPS TOTAL CALCULATED DEMAND LOAD = 5,947 VOLTAMPS 4 #1 THWN CU #6CU GND — 1 -1/4 ° C XCEL ENERGY 75KVA 120/208V THREE PHASE TRANSFORMER 13,000 ISCA 3P, 4W, N3R FUSED DISCONNECT O WITH f A 100A FRN —R 1V 1 FUSES 6,175 ISCA PROVIDE #6 CU BONDING JUMPER TO NEW DISCONNECT AND METER TO PANEL GROUND BUS #1/0 AL URD QUADPLEX RATED FOR DIRECT BURIAL ONE LINE DIAGRAM 16.5 (F.L. AMPS) 100AMP MAIN BREAKER PANEL 3PH, 4W, SN 16 CKT MIN N #6 CU MIN GND ROD METAL WATER PIPE SERVICE & BLDG STEEL I L — P x 13,000 ISCA 3P, 4W, N3R FUSED DISCONNECT O WITH f A 100A FRN —R 1V 1 FUSES 6,175 ISCA PROVIDE #6 CU BONDING JUMPER TO NEW DISCONNECT AND METER TO PANEL GROUND BUS #1/0 AL URD QUADPLEX RATED FOR DIRECT BURIAL ONE LINE DIAGRAM 16.5 (F.L. AMPS) 100AMP MAIN BREAKER PANEL 3PH, 4W, SN 16 CKT MIN N #6 CU MIN GND ROD METAL WATER PIPE SERVICE & BLDG STEEL ltll ElechicalServices,7DC DEAN KUNTZ 11433 N I70 FRONTAGE RD N = \ P x m� $ _ .... ......................._....... 11437 W I70 FRONTAGE RD N, WHEAT RIDGE, CO 80033 PHONE (303) 202 -5030 WHEAT RIDGE, CO 80033 , BE W 202 -5029 2 FAX