Loading...
HomeMy WebLinkAbout3405 Estes Streeti CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: q Qq ` F, I d f Rto—f Job Address: ? Lf d `s E >t es 3 Permit Number: o =-? ❑ No one available for inspection: Time PM Re -Inspection required: Yes i 1/ When corrections have been made, call for re -inspection at 303-234-5933 Date:_ Inspector: bene. DO NOT REMOVE THIS NOTICE r , i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 h ,,�roo'f Job Address: Jg07 64-#-x"5 S+, Permit Number: `l 01d 02- 3'? 5 1174f , A",-00 sl 0 ❑ No one available for inspection: Time AMS Re -Inspection required: Yes When corrections have been made, call for Mre-inspection at 303-234-5933 Date: 0 Inspector: rE EO V-6 f DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201802375 PERMIT NO: 201802375 ISSUED: 08/28/2018 JOB ADDRESS: 3405 Estes St EXPIRES: 08/28/2019 JOB DESCRIPTION: Reroof remove and install CeDUR Walden Polyurethane Roofing Shake Shingles with 34.89 squares. Pitch 4/12. House. **Install to Manufacturers installation specification sheets provided by contractor** *** CONTACTS *** OWNER (303)908-1614 BOULEE EDMOND A SUB (303)902-5338 Phillip Simon/Steve Merkel 170232 Simon Bros Roofing & Restor. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 50,000.00 FEES Total Valuation 0.00 Use Tax 1,050.00 Permit Fee 729.55 ** TOTAL ** 1,779.55 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. a r A A( City of Wheat Ridge V, _1�9 Residential Roofing PERMIT - 201802375 PERMIT NO: 201802375 ISSUED: 08/28/2018 JOB ADDRESS: 3405 Estes St EXPIRES: 08/28/2019 JOB DESCRIPTION: Reroof remove and install CeDUR Walden Polyurethane Roofing Shake Shingles with 34.89 squares. Pitch 4/12. House. **Install to Manufacturers installation specification sheets provided by contractor** I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or000NTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off Bial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The =ianting a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applany nance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Lagenia Reimer 0_/W� From: no-reply@ci.wheatridge.co.us Sent: Tuesday, August 28, 2018 9:51 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued it the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. The Building Division permit counter is open from 7:30 am to 3:30 pm, Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name 3405 Estes Street Ruth and Ed Boulee Property Owner Phone 3039081614 Number (enter WITH dashes, eg 303-123-4567) 17,11 �� Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. r.boulee@yahoo.com Yes Attach Copy of Executed Contract. Boulee 3405.1)df Contract CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Simon Bros roofing and Restoration, LLC 170232 303-902-5338 Contractor Address 6803 E 47th Avenue Dr Unit B (Primary address of your business) Contractor Email Address simonbros.roofing@gmail.com Retype Contractor Email simonbros.roofing@gmail.com Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or 34.89 $50000 No Pitched roof (2:12 pitch or greater) 2 both? (check all that apply) What is the specific pitch 4:12 of the PITCHED roof? How many squares are 34.89 part of the PITCHED roof? Describe the roofing Cedur Walden materials for the PITCHED roof: Type of material for the Other PITCHED roof: If "Other" is selected Cedur Walden above, describe here: Provide any additional House detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. 3 I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Marisela Porras Permit Email not displaying correctly? View it in your browser. ao � `-' 3 ACOS without the splitting, rotting, warping, and risk of fire �1 ,' • •• •• inherent to natural cedar shakes. ►•��, • • • CeDUR Roofing Shakes are developed to withstand nature's harsh elements while providing the classic beauty of natural cedar CeDUR Timeless • Durable • Beautiful • Class A Fire Rating (highest rating available), without the need of a special fire-resistant underlayment • Class 4 Impact Rating (highest rating available) • Molded from natural cedar shakes with 5 7 and 12" shakes and a 3/4" butt, which gives deeper shadow lines making your roof virtually indistinguishable from natural cedar shakes • Potential reductions in Homeowner's insurance - listed on most major insurance companies premium credits product listing • Synthetic roofing product that ages to a beautiful wood color • Solid product - no cavity back (Color Through Pigmentation) • Manufactured in Colorado using State -of -the -Art Polyurethane Technology, CeDUR installs just like natural cedar shakes • Wind resistant - certified to wind gusts up to 115 mph • Improves the insulation value of your roof • Lightweight product - just 170 lbs per square • 50 Year Limited Material Warranty Patent 10 60 V * O ♦i CQ • • V �� 'V1�► Zii MEMBER �o Update Effective October 12, 2017 CeDUR Timeless Durable • Beautiful Installation Recommendations Introduction- CeDUR"" Shakes CeDUR'"" Shakes are inspired by the enduring beauty of natural cedar shakes. CeDUR"" is manufactured using state of the art polyurethane technology that was developed to withstand harsh: fire, hail, wind, and UV conditions. Discerning property owners choose CeDURTM as the low maintenance, high performance roofing product that enhances the beauty and value of their property. The product combines the beauty of natural cedar shakes with unsurpassed durability and ease of standard shakes installation methods. CeDURT" Shakes are a lightweight, fire, hail, and wind resistant product that are ideal for projects that demand a natural cedar shake appearance. CeDURTM Shakes are • UL 2218 Class 4 impact rated • Class "A" Fire rated without the requirement of a special fire-resistant underlayment. ASTM E 108, UL 790 • Rated @ an insulation value of R > 2.0 R factor (approximately 20% greater than natural Heavy Cedar Shakes) • 115 mph wind resistant rated for the "Standard Application" — at a 10" exposure. ASTM E330, UL 1897 (warrantied to 90mph) • Above 115 mph wind resistance installations are considered "High Wind Application" — consult CeDURTM. • Resistant to water absorption. • Colored throughout for stability and uniformity at cuts. Solid product, no cavity back. • Lightweight (170 lbs. per Square). • Resistant to rot, moss, and insects • CeDURTM Shakes are protected by a 50 Year Limited Material Warranty. • Ideal for new construction and re -roofing applications for residential and commercial projects Design CeDURT" Shakes are a realistic synthetic shake alternative with a nominal 3/4" thick butt edge which tapers to 1/8" thick. It is manufactured in three widths: 5'/4 ", 7'/4", and 12'/4" & four natural wood colors. The shakes are reproductions of natural wood cedar shakes. CeDURT^" Shakes provide a personal preference option for architectural compatibility, roof appearance, fire resistance and roofing weight. Refer to the CeDURT" Shakes Technical Specifications for details and coverage based on exposure and spacing between shakes. Page 1 Update Effective October 12, 2017 Pitch The minimum roof pitch for CeDURT" Shakes is a 4:12 slope. Applications below 4:12 are considered decorative. For pitches under 4:12, please consult CeDUR for proper installation recommendations. Roof Framing CeDURT"" Shake's lightweight system allows direct replacement of existing roof systems without the structural evaluations and enhancements necessary for heavier roofing products. This product feature also holds true for new construction. No unusual design or engineering considerations are required. CeDURTm Shakes weigh approximately 30% less than Asphalt Architectural Shingles and less than natural Heavy Cedar Shakes. CeDURT" Shakes are approximately 80% less than the weight of standard Concrete Roof Tile. Decking Install CeDURT" Shakes on solid decking consisting of either code -complying, 15/32" thick American Plywood Association (APA) rated plywood, APA rated wood panels, or other building materials meeting these minimum requirements in accordance with DOC PS -1. Temperature/Cold Climates — Storage & Installation CeDURT"° Shakes should be stored at temperatures above 40°F and pallets should not be stacked more than two pallets high. CeDURT"' Shakes can be installed in temperatures as low as 20°F. Underlayment (For pitches 6:12 and above) No special underlayment is required for a Class A Fire rating One of the following base underlayment's is required as part of the normal application process. • One layer of Number 30 base sheet conforming to ASTM D 226 covering the entire roof deck; or alternatively, synthetic underlayment manufactured for and utilized for shingle underlayment purposes. Verify with the manufacturer that the specific base sheet is water resistant. • Ice Protection In areas where the average daily temperature in January is 25°F (-4°C) or less, install an ice barrier that consists a self -adhering polymer modified bitumen sheet in lieu of normal underlayment at the eaves. Extend ice protection underlayment from the eaves edge to a point at least 24 inches (610mm) inside the exterior wall line of the building. • Valley's Install a high temperature ice/water barrier that consists of a self -adhering polymer modified bitumen sheet in lieu of normal underlayment at the valley's. To assure proper horizontal alignment we recommend that chalk lines be snapped frequently. These chalk lines should be placed on the underlayment so that the shakes are aligned by the tips rather than the butts. Chalk Lines should be snapped on the underlayment with the tips of the shakes following the lines. Do not snap lines on the CeDURTM Shakes or use red chalk as the chalk may permanently discolor the shakes. Page 2 Update Effective October 12, 2017 Note: A base (dry in) underlayment may be installed covering the entire roof deck prior to the CeDURT" Shake installation assembly described above as a temporary dry -in if desired or if required by local building codes. The CeDURTm roofing system can be installed over existing temporary dry -in providing the material lays flat and tight to the roof deck. Underlayment (For pitches between 4:12 and under 6:12) In addition to one of the base sheet options described above, install one layer of ASTM D 226 type 11 36 -inch NO 30 underlayment at the eave line. After applying the starter shakes, a minimum 18" wide strip of interlay of ASTM D 226 -type II (ASTM D 4869) No. 30 shall be laid over the top portion of the starter shakes, the butt end of the interlay course extending up-slope onto the sheathing and/or dry -in, approximately 9 inches above the fascia (For a 1 inch overhang). After installing the field shakes over the starter shakes, position the bottom edge of the next interlay on the 10 -inch line of the interlay previously installed, with successive courses laid on the 10 -inch line (or less depending on roof layouts less than 10") Refer to the installation diagram following the written text. Note: Felt interlayment on the CeDUR'"" Shakes is to be installed so it does not extend below a line that is twice the exposure above the butt (i.e. a 23.5" shakes at 10", exposure would have felt applied 20" above the butt). No felt should be visible between the side joints of the shakes (keyway). Refer to the CeDURTM Shakes Technical Specification Details. Starter CeDURTM Shakes "Starter" is to be installed at all eave-lines. Butts of the starter shakes and first course of CeDURTN1 Shakes are to project equally beyond the finished fascia as determined by conditions to insure proper water drainage. Typical installation is a 3/4" - 1 inch (25.4 mm) overhang. Where gutters are present, the overhang may be adjusted to insure proper water flow into the gutters. Secure each 15" CeDURTM Starter with four corrosive resistant fasteners. Refer to the CeDURT"" Shakes Technical Specification Details. Gable Ends - Rakes Extend CeDURTI Shakes approximately 3/4 inch over gable - rake ends. Exposure A 10" (254 mm) weather exposure for straight-line installations is standard, and has been used for all calculations, testing and certifications, and the basis for the product warranty. When 1" staggered installation is used, shakes exposure is laid at 9" (229 mm) exposure and random shakes are at 10" (254 mm) exposure or 1" (25.4 +/-) stagger. The maximum recommended stagger is 2 inches (8" exposure). Spacing (Keyway) & Joint Off -Set CeDURTM Shakes are resistant to water absorption. Expansion and contraction due to temperature or moisture content fluctuations (hot/cold, wet/dry or freeze/thaw) is negligible, thereby Page 3