Loading...
HomeMy WebLinkAbout4765 Saulsbury StreetEGRESS WINDOW INSTALLATION APPROVAL Job No. WWM98-21790 Date Signed: November 15, ItISWell Windows and Egress 17059 E. Wiley Place Parker, Colorado 80139 Attention: Trevor Nicola Re: Egress window for the residence at: 9765 Saulsbury St., Wheat Ridge Dear Mr. Nicola On this date Crown Jade Design and Engineering personnel or representative under my supervision and in direct contact with me observed the structure of the egress window, with a U value of 0.28, per the detail on file at the project site. The egress window as designed was installed satisfactorily as was the liquid applied flashing membrane Quad Flash by OSI to seal the openings. Thank you for retaining our firm to perform this structural evaluation service. Very truly yours, DOUGLAS INGERSOLL, EI, BSME MARK BENJAMIN, PE, MSCE, SECB, CPHC {Certified in the practice of structural engineering} Certified Passive House Consultant Copies: (2) To do our part to save resources: Provide both to your contractor for distribution, or provide one photocopy to the homeowner for their records. Contact our office for an electronic version to be emailed to you if so desired. Engineered for the way you build ... ... Designed for the way you live. IN ME EXISTING CONCRETE FOUNDATION CUT A HORIZONTAL SLOT FOR TUBE STEEL PLACEMENT = R O + 9" WIDE X ZDEPTH. CUT HORIZONTAL AND VERTICAL ROUGH OPENINGS • 3" FOR MMMING ALL SIDES INFILL BETWEEN NEW HUS HEADER AND NEW WINDOW AS REQUIRED. THE NEW WINDOW LOCATION MAY BE ALIGNED WITH BOTH SIDES OF THE EXISTING WINDOW. NOTES • TEMPORARY SUPPORT 5 REQUIRED ON ALL LOAD BEARING WALLS PRIOR TO DECONSTRUCTION • WINDOW WELL SHALL BE 9 N]. F. MIN. AREA WITH BE MIN, CLEARANCE FROM FOUNDATION WALL TO INSIDE OF WELL. • A PERMANENT LADDER 6 REQUIRED IN ME WINDOW WELL IF B070M OF WELL IS M" OR MORE BELOW GRADE. • IN CASES WHERE ME NEW EGRESS WINDOW'S R.O. IS LESS THAN OR EQUAL TO THE EXSTING WINDOW WIDTH. THE EXISTING HEADERILIMEL IS SUFFICIENT TO SUPPORT THE MAXIMUM DESIGN LOAM IMPOSED. NO ADDITIONAL SUPPORT REQUIRED. • FILL GAPS BETWEEN NEW HSS AND CONCRETE WITH MORTAR OR NON SHRINK GROUT • DRAINAGE TO EXISTING FOUNDATION DRAINAGE SYSTEM REQUIRED • GENERAL AREA WELL CODES APPLY. REFER TO IRC R310.3.2 IF PRESENT, EXISTING STEEL LINTEL AT — BRICK VENEER i0 REMAIN. OTHERWISE. BRICK i0 BEAR ON NEW HTS$ HEADER III V T Vies MIN. ENSURE CONCRETE CONTACT ON TOP CN SLOT Be ED REARING. MIN, TYPICAL BOTH ENDS. MORTAR INFILL OF LOOSE CRUMBLED CORNERS REQUIRED BUT NOT CONSIDERED STRUCTURAL AS PART OF F BEARING These Letter all ressawal anal the Kable laws in i at the else & wants Rental LHw 'Hall H these Eatal still 11 01 skeeter W View nflo�weale�, als,nalat RRY seensishinThai Qty: (1) 30" x 48" Location: Basement West wall Type: Casement U Value: .28 At existing window YES Existing lintel or header YES Window above YES Floor joist bearing YES Brick Veneer al TOUTS AND DECKING STREET ADDRESS: N crown jade 4765 Saulsbury St. JOB IF TOP OF V UK. FOUNOAOON S\ Wheat Ridge EXISTINGWINDOW WWAE98-21740 DESIGN AND ENGINEERING ------------ TP 4165 OLITTENiON LN.: 09,1WELLINGTON R.O.+S'• O SCALE: NONE SHEET (970)471-2399 'VERIFY DIMENSIONS 1N 1 01G WITH WINDOW wrm.crovmjaaemm MANUFACTURER, AND 1 ADJUST SAWCUT yCLUB CALU DIMENSIONS IF TRIMMER REQUIRED. y PLACEHORI ONTAIi NAILER SILL SNUGLY sc 0 BETWEEN VERTICAL EPC NNLERS. rq 2 an a E\A/ 2'1-X4'4 EGRESS WINDOW OPENING - INTERIORMIN, Y♦ SCALE: NONE I Mark Benjamin P.E. have observed the proposed installation and determined that this detail meets existing conditions. Building Code: 2018 IRC/IBC '�A -% I Roof Snow: 30 psf tewawa° R Ground Snow: 30 psf Nominal/V-U1t. Wind Speed: 135 mph; 3 sec. gust. DEC. C Seismic Design: Category B PHINDILE, Me 0II STREET ADDRESS: ENGINEER'S crown jade 4765 Saulsbury St. JOB IF Wheat Ridge WWAE98-21740 DESIGN AND ENGINEERING 4165 OLITTENiON LN.: 09,1WELLINGTON Me 80522-0011 SCALE: NONE SHEET (970)471-2399 1N 1 01G CHECRBBYBY:IMB wrm.crovmjaaemm 1 From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Egress Window Pennit Application Date: Tuesday, October 5, 2021 10:38:54 AM Residential Egress Window Permit Application This application is exclusively for RESIDENTIAL EGRESS WINDOWS ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORMAN D ENGINEER LETTER STAMPED DETAIL SHOWING THE U -VALUE OF THE WINDOWCUT IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes existing EGRESS window(s) needing vertical cuts only? PROPERTY INFORMATION Property Address 4765 Saulsbury St. Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address - Do not enter a contractor email address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Lycel Teed 1918191-010101.1 [till Thomasteed@yahoo.com Saulsbury St Payment Form.odf CONTRACTOR INFORMATION Contractor Business Mosley & Boyd Construction Name applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Dion Mosley III Permit Email not displaying correctly? View it in your browser. Contractor's License 210210 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 7208228131 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email dmosley@mbconstr.com Address Retype Contractor dmosley@mbconstr.com Email Address 01 :K161 Ci 191 [*] 0 N] avOLe] N :/ Number of EGRESS 1 windows being replaced Location of EGRESS Basement window(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the u -value of 0.28 the EGRESS window(s)? City of Wheat Ridge requires the u -value to be .30 or better on windows. Attach copy of 21-098-1-4765 Saulsbury St -Wheat Ridge -SIGNED Ddf Engineer stamped letter showing vertical cuts detail and u -value Project Value (contract 3950 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with � ► � i City of Wheat Ridge Residential Remodel PERMIT - 202101111 PERMIT NO: 202101111 ISSUED: 06/25/2021 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 06/25/2022 JOB DESCRIPTION: Adding a kitchenette, plumbing work will be done to add a kitchen sink, hook up appliance like dishwasher. Add electrical lines for kitchen appliance and add a hook up to washer. No wall will be removed or added. 180 sq ft *** CONTACTS *** OWNER ( 72 0) 731-8624 TEED LYDIA CECILIA *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 15,410.00 FEES Total Valuation 0.00 Plan Review Fee 194.61 Use Tax 323.61 Permit Fee 299.40 ** TOTAL ** 817.62 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. NOT APPROVED AS AN INDEPENDENT OR ACCESSORY DWELLING UNIT. 1* ► � i City of Wheat Ridge '/� Residential Remodel PERMIT - 202101111 PERMIT NO: 202101111 ISSUED: 06/25/2021 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 06/25/2022 JOB DESCRIPTION: Adding a kitchenette, plumbing work will be done to add a kitchen sink, hook up appliance like dishwasher. Add electrical lines for kitchen appliance and add a hook up to washer. No wall will be removed or added. 180 sq ft I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/25/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. MMW neat �L ge 64 L� state alichow3wip cwbmya� Its 12ft onlyNOTA�ROVED AS AN Ir I'o ` Kitchenette � 1 - p 4 t,¢ _NL C °'#ttR SMOKE ALARMS AND CARBON MONOXIDE DETECTORS TO COMPLY WITH 2018IRC R314 AND R315. SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING ROOM, OUTSIDE OF SLEEPING AREAS, ON EACH STORY, AND BE INTERCONNTECTED. CARBON MONOXIDE ALARMS OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITYOF THE BEDROOMS. COMBINATION DETECTORS ARE PERMITTED. All work shall comply with the 2018 IRC, 2020 NEC and City Municipal Codes 12' 275 27" 29 5" MICROWAVE +STORAGE 01 r 2' KITCHENETTE DESIGN GENERAL FLOOR PLAN 7/8" 5' 10, Ch or '(KWQ- t N ici *e' "REVIEWED FOR CODE COMPLIANCE" These drawings were reviewed under the applicable laws In effect at the time of submittal. Reasonable effortwas exercised In checking for cod=_ compliance. The stamping of there documents shall not be construed to be a permit for, or an approval of any violation of state and/or local codes, ordinances or amendments thereto. Plan Reviewer Sones Date 06/22/2021 -Fire Blocking and Draft Stopping shall be installed in concealed spaces per R302.11 & R302.12. -Minimum Ceiling height shall be 7' or accordance with section R305.1.1. -Smoke Alarms shall comply with R314. -Carbon Monoxide Alarms shall comply with R315. -Kitchen exhaust hood systems capable of exhausting in excess of 400 cfm shall be provided with makeup air at a rate equal to the exhaust rate per code M1503.4 and City Amended Code. -For new fuel gas appliance please provide to the inspector at the time of rough inspection an isometric fuel gas piping diagram. The fuel piping diagram shall include the existing fuel gas piping as well as the new fuel gas piping. The calculations shall be for the complete fuel gas system per code section G2413. 1) Minimum net clear opening area: 5.7 sq. ft. or 5.0 sq. ft. at grade floor or below grade 2) Minimum net clear opening height: 24" 3) Minimum net clear opening width: 20" 4) Maximum sill height: 44" From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Interior Remodel Date: Tuesday, May 25, 20212:08:30 PM Residential Interior Remodel This application is exclusively for Residential Interior Remodels and other scopes of work which do not have a specific form already available. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 4765 Saulsbury St Wheat Ridge Colorado 80033 Property Owner Name Thomas Teed Property Owner Phone 720-731-8624 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Thomasteed@yahoo.com Address Attach City of Wheat BOB97534-FA3E-49DD-8EA5-45B3BDF09419.ioe Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" APPLICANT INFORMATION Applicant Name Thomas Teed What is your role in the Property Owner project? Are you performing the Yes work yourself, live in the home and will be living in the home 1 year after completion? Attach Notarized Homeowner Authorization Form Contact Phone Number (enter WITH dashes, eg 303-123-4567) Contact Email Address for Plan Review Comments EDD20D47-A79D-434E-BEFC-ODE8589A6D44.ioea 720-731-8624 Thomasteed@yahoo.com Retype Contractor Thomasteed@yahoo.com Email Address DESCRIPTION OF WORK Detailed Scope of Work - In the space below (not as an attachment), Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc I, the applicant, understand my application will be rejected if I do not include a Detailed Scope of Work. Adding a kitchenette, plumbing work will be done to add a kitchen sink, hook up appliance like dishwasher. Add electrical lines for kitchen appliance and add a hook up to washer. No wall will be removed or added. I have entered a detailed scope of work. Location of Work Basement Square Footage Area 180 of Work Being Performed Asbestos Report Field not completed. Upload letter size Field not completed. documents here Construction Plans Kitchenette floor. pdf scanned on 11'x17" or larger Project Value (contract 15000 15,410.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Thomas Teed Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. MMW neat �L ge 64 L� state alichow3wip cwbmya� Its City of Wheat Ridge E -Res. Evaporative Cooler Repl PERMIT - 202001610 PERMIT NO: 202001610 ISSUED: 08/17/2020 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/17/2021 JOB DESCRIPTION: Replacing evap cooler, 5500 CFM on roof. *** CONTACTS *** OWNER (303)999-8130 TEED TOM SUB (303)422-5308 STEVE BRANDT 021365 THE COOLER COMPANY *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,000.00 FEES Total Valuation 0.00 Use Tax 105.00 Permit Fee 125.05 ** TOTAL ** 230.05 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. City of Wheat Ridge E -Res. Evaporative Cooler Repl PERMIT - 202001610 PERMIT NO: 202001610 ISSUED: 08/17/2020 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/17/2021 JOB DESCRIPTION: Replacing evap cooler, 5500 CFM on roof. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, T. ' uance or gra ti g of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any r 1... ble ode or ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dina Kemp From: no-reply@ci.wheatri dge.co.us Sent: Friday, August 14, 2020 1:50 PM To: CommDev Permits Subject: Online Form Submittal: Air Conditioner/Evaporative Cooler Permit Application Categories: Dina Air Conditioner/Evaporative Cooler Permit Application This application is exclusively for AIR CONDITIONER OR EVAPORATIVE COOLER. YOU MUST ATTACH THE ELECTRONIC PAYMENT FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Is this a new install or replacement for an existing AC unit? Is this Residential or Commercial? Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - **DO NOT ATTACH A PICTURE OF A CREDIT CARD** Replacement of Existing Unit Residential 4765 Saulsbury St Tom Teed 303-999-8130 thomasteed@yahoo.com Wheat Ridge payment form.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) The Cooler Company 021365 303-422-5308 Contractor Email Address lori@thecoolercompany.com Retype Contractor Email lori@thecoolercompany.com Address DESCRIPTION OF WORK What type of replacement Evaporative Cooler unit are you installing? How many tons is the It's a cooler not ac unit? For AC - what is the 5500 CFM SEER? For Evaporative Coolers, what is the CFMs? Where is the unit located Roof (for example, rooftop, backyard on ground etc)? Is electrical needed for re- Yes hook? Provide Electrical 021365 Contractor's Wheat Ridge License No. Project Value (contract 5000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat 2 I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Kim Earnheart Permit Email not displaying correctly? View it in your browser. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:_ ["Cn) Job Address: t 7 '7 4 P" Permit Number:" ❑ No one available for inspection. Time Re -Inspection required: Yes, No When corrections have been made, call for re -inspection at 303-234-5933 Date Inspector: 'Y�­ DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division �(303) (303) 234-5933 Inspection line235-2855 Office • (y33003) 237-8929 Fax ', `f'/of -13 Z:;;Pi INSPECTION NOTICE Inspection Type: �75_ fC r Job Address: Permit Number:l n / ❑ No one available for inspectiom. Time I L `SAM/P Re -Inspection required: Yep No When corrections have been made, call for re -inspection at 303-234-5933 Date: 9, % + Inspector: -- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax I SPECTIO NICE Inspection Type: Job Address: __- u Zia f Z-2% Permit Number:'' ❑ No one available for inspection: Time Re -Inspection required: Yes 16-0111-) When corrections have been made, call for re -inspection at 303-234-5933 Date: 2!5�A-' " l`� Inspector: j�----- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Vo) I e c IV : c6l Job Address: ` NoN ' 5 - Permit Number: '101 � o d l ❑ No one available for inspection: Time CXIVy AA PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date: _Inspector: ! r DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: (� Job Address: C' Permit Number: j /-- ❑ No one available for inspection: Timer` . ;MPM Re -Inspection required•'/ 0 When corrections have been mad cad 11 fort-ir�peetienat 303-234-5933 Date. `Z.-GQnsppecto . i I DO NOT RE' E THIS NOTICE i CITY OF WHEAT RTOGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: SE 5f < Permit Number: ❑ No one available for inspection _,13,mper�7 _y Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date:e/ 91 z^ inspector: -- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Jy ` fir, �i t✓t �f =` r i/Nrid Job Address: `!6 s Permit Number: ❑ No one available for inspection: Time r,� PM Re -Inspection required: Yes /NO) When corrections have been made, call for re -inspection at 303-234-5933 -.r Date: /,, / i�, Inspector: Done (el -e r4t DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE �Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ' fl LlNo one available for inspection: Time `! , 6 'A'") PM Re -Inspection required: Yes ,Na t.,.�" When corrections have been made, call for re -inspection at 303-234-5933 Date: ` f Inspector: i�,� rnId DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION- )NOTICE � � 1 Inspection Type: �r'C� -��n ff _ // !{ �Ji %C.('(i`GL" . Job Address: _jsi ' J Permit Number: l' f), f'O_� "S( 'r - Ll ❑ No one available for inspection: Time 0. r) 5 AIM�PM Re -Inspection required: =/1( �' No When corrections have been made, call for re -inspection at 303-234-5933 i Date: t z / ` Inspector: s evL C, DO NOT REMOVE THIS NOTICE ® ! s_ CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 13- _ � r�� �X �� � % ��� �, k �' 4�r: n; err Job Address: ?o 5- Permit Number:. ❑ No one available for inspection: Time Re -Inspection required:SYe 1 No ,__ When corrections have been made, call for re -inspection at 303-234-5933 1: Date: %' ' Eft Inspector: 'rl_ Gvf - DO NOT REMOVE THIS NOTICE Kimberly Cook From: Juan Alvidrez <JARplaza@msn.com> Sent: Friday, November 30, 2018 10:23 AM To: Kimberly Cook Subject: 4765 Saulsbury st Kim, Please update the list of employees can pull permit from Plaza Construction new list is Juan Alvidrez, Flor Alvidrez and Cynthia Alvidrez. Thank you please cancel the permit that was issue for 4765 Saulsbury st Wheat ridge 80033. Thank You! Juan Alvidrez President Phone: 303-573-0190 Fax: 303-623-0631 www.MvPlazaConstruction.com Our Facebook page City of Wheat Ridge Residential Roofing PERMIT - 201802231 PERMIT NO: 201802231 ISSUED: 08/09/2018 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/09/2019 JOB DESCRIPTION: Reroof and Redeck House back patio remove and install Certainteed Flintastic GTA Modified Rolled Roofing System with 3.75 squares. Pitch 1.5/12. *** CONTACTS *** OWNER (303)422-3085 REEVES PATRICIA A SUB (303)438-1007 Doug Breinig/Melodi Breinig 140189 J&N Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,000.00 FEES Total Valuation 0.00 Use Tax 42.00 Permit Fee 77.50 ** TOTAL ** 119.50 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201802231 PERMIT NO: 201802231 ISSUED: 08/09/2018 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/09/2019 JOB DESCRIPTION: Reroof and Redeck House back patio remove and install Certainteed Flintastic GTA Modified Rolled Roofing System with 3.75 squares. Pitch 1.5/12. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, an violation of any provision of any applicable code or any orcr�}ance or regulation of this jurisdiction. Approval of work is subject to f any inspection. tea- e Signaturew of Chief 13ilding Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Lagenia Reimer �a t rO 0 2 2--,, From: no-reply@ci.wheatridge.co.us Sent: Thursday, August 9, 2018 3:50 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. The Building Division permit counter is open from 7:30 am to 3:30 pm, Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) 4765 Saulsbury St John Jaen 720-765-0549 c -e Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. johnjaen@gmail.com Yes Attach Copy of Executed JN roofing 4765 saulsbury signed contract.pdf Contract CONTRACTOR INFORMATION Contractor Business J&N Roofing Name Contractor's License 140189 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-438-1007 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 1180 S. Balsam St. (Primary address of your business) Contractor Email Address jnroofing1 @comcast.net Retype Contractor Email Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or jnroofing1 @comcast.net 375 square ft 2000 Yes Flat roof (less than 2:12 pitch) z both? (check all that apply) What is the pitch of the FLAT roof? How many squares are part of the FLAT roof? Describe the roofing material for the FLAT roof: Type of material for the FLAT roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 1.5/12 375 sq ft. Certainteed Flintastic GTA modified rolled roofing system TPO/EPDM House Back Patio flat roof only SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to 3 submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Nathan Breinig Permit Email not displaying correctly? View it in your browser. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 c 8- R o A f f -ec Job Address: '-)-71'S- S a u is va-w 07L Permit Number: a o i 8 0 a a 4) ❑ No one available for inspection: Tirr Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 DateC----h)spect_ :. DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -30 X E Job Address: y Sgv1S ver Permit Number: /V/-) AmtI�VrD(v w I- 14 h 4/, 0j;4 5 a1 P 4, 4rj, f 0fi r/P '� t �aiq % Cl e ❑ No one available for inspection: Time AM/PM Re -Inspection required: Ye;> No When corrections have been made, call for re -inspection at 303 -234 - Date: q �� iii Inspector: %%i T# DO NOT REMOVE THIS NOTICE Y-4-- CITY OF WHEAT RIDGE Building Inspection Division, (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: _-w C h P � 0 OA Q Job Address: 477 L Scw i bu�� gf Permit Number: _ ao I ?C)02 (0 r J t /► 1 J/ 1 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date:— R f Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE jA Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: t V1 Job Address: 4'i (OS- 451�L'a (50v r Permit Number: '26/k® ( 3Fr ❑ No one available for inspection: Tina" AM/PM Re -Inspection required: Yes t;No�i When corrections have been made, call, for ri_e' ct on at 303-234-5933 gip" f Datef ` t Inspect"o�!-____ DO NOT NOT REM01VE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M_04eJ1 F_ -- L Job Address: q:j f6U U V Permit Number: o2D1'�6k)ZI S6 I ❑ No one available for inspection: Ti M PM Re -Inspection required: Yeso � When corrections have been ma" e,_ cal -inspection�at2303-234-5933 Date Ins eir� DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building; A City of Wheat Ridge `rr Residential Remodel PERMIT - 201802261 f� PERMIT NO: 201802261 ISSUED: 08/21/2018 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/21/2019 JOB DESCRIPTION: Remodel of main level and basement - 2,620 sq ft total; Main Level: new flooring, new kitchen cabinets, bathroom vanities; adding a shower in upstairs existing closet; replace windows -1,310 sq ft; Basement level: new drywall ceiling, finish roughed -in bathroom, new LED lights, fur out and drywall two walls in both bath and office; 2 new egress windows - 1,310 sq ft *** CONTACTS *** OWNER (720)765-0549 JAEN JOHN GC (303)573-0190 Juan Alvidrez 090253 Plaza Construction SUB (720)998-2250 Ryan Underwood 180234 Mastiff Electrical Solutions SUB (720)361-0200 Rashad Gordon 180259 Pipe It Up *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 40,000.00 FEES Total Valuation 0.00 Plan Review Fee 399.46 Use Tax 840.00 Permit Fee 614.55 ** TOTAL ** 1,854.01 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. City of Wheat Ridge Residential Remodel PERMIT - 201802261 PERMIT NO: 201802261 ISSUED: 08/21/2018 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/21/2019 JOB DESCRIPTION: Remodel of main level and basement - 2,620 sq ft total; Main Level: new flooring, new kitchen cabinets, bathroom vanities; adding a shower in upstairs existing closet; replace windows -1,310 sq ft; Basement level: new drywall ceiling, finish roughed -in bathroom, new LED lights, fur out and drywall two walls in both bath and office; 2 new egress windows - 1,310 sq ft I, by my signature, do hereby a st that the work to be performed shall comply with all accompanying approved plans and specifications, applicable uildi codes, an al applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal ow of the pro a and am authorized to obtain this permit and perform the work described and approved in conjunction with this pe rt. I fu er attest t at am legally authorized to include all entities named within this document as parties to the work to be perfb and t all wor to a perf" med is disclosed in this document and/or its' accompanying approved plans and specifications. Alfiadrn NA&N 211( fi Signature oT7VVXER oD ZONTRACTOR irclefone) Date 1. This per ed on the ipforn ion provided in the permit application and accompanying plans and specifications and is subject to eet pliance w� ents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This perrm , s a 1 expire 365 days a the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or grant' of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any app ale code or an rdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of' Or Wheat j COMMdgc UNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 43 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(fti.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # '�c Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** � Property Address: i-12� W1S Property Owner (please print): 76 _T�L& Phone: ® ( Property Owner Email: Tal -01 Tenant (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: ro a 00 W ; 2 a V11'_ d City, State, Zip: ui�kka4 iz4 ctaf _ 66&� 3 Architect/Engimers C_&_�LU Lj__� UJ Architect/Engineer E-mail: � ao , (6 Phone: Contractor: 94 4 iku City of Wheat Ridge License #: Phone:G� Contractor E-mail Address: V )� ) X11 d �-e 70a AA, J -W ��� lLf i%l5`�Y�,C il✓t . VA For Plan Review Questions & Comments (please print): (p print): &L)�' o �C CONTACT NAME lease rint : l✓ hone: CONTACT EMAIL(p/ease Cv J oV� r� j cue V� E' '*- u i t , Sub Contractors (Must provide Wheat Ridge License�V0.): Electrical:t{rG't i"jC Plumbing: �t i ! k %C Mechanical: W.R. City License 1�j22 W.R. City License # i.� W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # C_ --c `'L J ❑ COMMERCIAL [glt'ESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. UernoK-tb,n "t Kktl �., I bA:,room- 4Lc %. mat Rr. ail did cQ rpcf 1 re,6V t- L I•��rv\woz:�w �Q�iravJS tn�lvd� 2w e�f-csj ✓L�I�wS . rJ V_V�r. �tvA{S ( IJe1-kroan,_ ✓i- ALttjeS . �Ic-r�cs.� �can.l v(Jyd� , rt t -cd. PI .�� : w\ 1 t, • gln�,� t r �.p5 (5 -eye 41' 1 C_'o S�C-"{_ , .I ►��( �`n j �'.I,l trvau�-�,� �v. ��`n.�l t -� l�c� `,� ►�.c�4^�°ori WQ-t�� Co Commercial ProjectsOnly: Occupancy Type: ! ns tion Ty Sq. Ft./LF 64" t t'tTus Gallons Amps Squares Project Value: (Contract value or the cost of all materials and labor included in the entire project) 5 ofi(�tC—C OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the app ca ion. CIRCLE ONE: (OWNER) (CO R) or (A T ORIZED REPRESENTATIV of (OWN) (CAN/T CTOR) T Signature (first and last name): j) � / � � DATE: / �( _/y Printed Name: �` " a -I l l t u i/10l.Ci OL DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: I Reviewer: BUILDING DEPARTMENT COMMENTS: _ 1 Reviewer: f 1 PUBLIC WORKS COMMENTS: Reviewer J, Building Division Valuation: 9 0, V 0 0 City of See attached list for additional requirements that W heat I�dge apply to this project. COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Review is limited to the contents of the plans submitted and any errors or omissions contained herein shall not be construed as permission to allow any conditions to exist in violation of the codes of the City of Wheat Ridge Rough Framing and Wood Requirements The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough heat and ventilation are complete. The building should be fully enclosed with the roof covering and siding in place. 2 Fire blocking shall be installed to cut off all concealed draft openings in the following locations: (IRC 302.11) A. In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor levels, and at 10 -feet horizontal intervals. B, At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, and cove ceilings. C. In openings around vents, pipes, ducts, cable, wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. D. In concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the run of the stairs at unfinished walls. 18 There shall be a floor or landing on each side of each exterior door, except where a stairway with 2 or fewer risers located on the exterior side of the door, other than the required exit door, a landing is not required for the exterior side of the door. The landing must be no lower than 73/ -inches below the top of the threshold of the door provided the door does not swing over the landing. (IRC R311) 19 Stairways must be at least 36 -inches in width. Handrails shall not project more than 4% -inches. The maximum rise may not exceed 7% -inches. The minimum tread depth may not be less than 10 -inches. Minimum headroom is 6 -feet, 8 -inches. For stairways with solid risers a nosing of %-inch to 1% -inches shall be provided. When open risers are used the opening between the treads shall not allow the passage of a 4 -inch sphere to pass through. Landings must be provided at the top and bottom of the stairway that is the width of the stairway measuring at least 36 -inches in the direction of travel. Handrails shall be provided on at least one side of stairways with 4 or more risers and ramps with a slope exceeding 1:12. Handrails shall be mounted 34 -inches to 38 -inches above the nosing of the treads. Handrails must be continuous for the entire length of the stairs and provided with a minimum space of 1% -inch between the wall and the handrail. Ends shall be returned or terminate in newel posts or safety terminals. See the requirements and more information. (IRC R311.7.8.2) 20 Handrail Grip Size Shall Be:A. Circular Handrails: 1% -inch to 2 -inches perimeter. B. Non -Circular: 4 -inches to 6% -inches perimeter with a maximum cross section of 2% -inches. C Perimeter Dimension Greater than 6% - inches: shall have a finger recess on both sides. 21 Guards must be provided for porches, screened porches, balconies, fixed seating and raised flooja6faces more than 30 -inches above the floor or grade below. Guards must have a minimum height of 36 -inches sides of stairs with a total rise of more than 30 -inches above the floor or grade below shall have guarlA of le 0 than 36 -inches high. Intermediate rails shall not allow the passage of a 4 -inch sphere. (R312) Window fall protection must be provided for window openings less than 24 inches above the finished floor and more than 72 inches above grade or surface below. (R312.2) 22 Safety glazing shall be installed in the following hazardous locations and be permanently labeled as safety or tempered glazing: glazing panels in doors; glazing enclosing spas, bathtubs or showers; glazing panels adjacent and within 24 -inches of the edge of a door; glazing panels greater than 9 square feet within 18 -inches of the floor; glazing used for railings; glazing used for barriers for swimming pools and spas; and glazing enclosing stairways, landings, and ramps within 36 -inches horizontally of a walking surface. See the Boulder County Land (IRC R308) Heating and Ventilation Requirements 32 Bathroom exhaust fans shall exhaust directly to the exterior and must be provided in bathrooms where windows of at least 3 square feet are not provided. The mechanical ventilation must be capable of providing an exhaust capacity of 50 cfm intermittent or 20 cfm continuous exhaust. (IRC R303.3, M1507.4) 33 Appliances and equipment shall be installed in accordance with the conditions of their listing. Manufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1, M1401.1,(M1902.2) 34 Appliances shall be accessible for inspection, service, repair and replacement without removing permanent construction. 30 -inches of working depth and width shall be provided in front of the control side of an appliance. (IRC M1305.1) 35 Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407) Electrical Requirements 36 All hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical connection at the time of rough inspection. 37 Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at least 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through the fixture into the ceiling cavity. (IRC N1102.4.5) 47 Tamper -resistant Receptacle outlets are required in every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14) 48 Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the counter top and spaced so no point exceeds 24 -inches from an outlet. B. Island and peninsula counters with a length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet. C. At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. 49 At least one receptacle outlet must be installed in each laundry, basement, attached garage and detached garage with power. F. At least one receptacle outlet that is accessible while standing at grade level and located not more than6-feet, 6 -inches (1981 -mm) above grade, shall be installed outdoors at the front and back of each dwelling unit having direct access to grade. Balconies, decks, and porches that are accessible from inside of the dwelling unit and that have a usable area of 20 square feet. F. Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet within25-feet of the equipment. G. Hallways 10 -feet or more in length. 50 Two 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining area. At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch circuit shall supply laundry. (IRC E3703.2, E3703.3, E3901) 51 Ground fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the following locations: bathrooms, garages, unfinished grade level accessory buildings, at exterior locations, crawlspaces, unfinished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks, boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location. (IRCE3902, E3902.11) 50 Combination type Arc -Fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch circuit outlets in Receptacle outlets are required in every family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, hallway, closets, and similar dwelling areas. (IRC 3902.12) 51 At least one wall switch -controlled lighting outlet shall be installed in every habitable room, bathroom, hallway, (10ft) stairway, attached garage, detached garage with electric power, and at the exterior side of each outdoor egress door having grade level access. Attics, under floor spaces, utility rooms and basements containing equipment or used for storage must be provided with a switch 52 Smoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring operated light. (IRC E3903)with battery backup and shall be interconnected so the actuation of one alarm will activate all alarms in the dwelling unit. Smoke alarms shall be installed in the following locations: (IRC R314) A. In each sleeping room; B Outside each sleeping area in the immediate vicinity of the bedrooms; and C. One on each additional story including basements. 53 Carbon Monoxide alarms are required in a single-family dwelling that has fuel -fired appliance(s), or a fireplace, or an attached garage. The alarm must be installed within 15 -feet of the entrance to each sleeping room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and has a battery backup. They may be combined with a smoke -detecting device if the combined device complies with applicable law. (IRC R315) 54 Clothes closet lighting shall be limited to surface -mounted or recessed incandescent fixtures with completely enclosed lamps, and surface -mounted or recessed fluorescent fixtures.Surface mounted fixtures shall be installed on the wall above the door or on the ceiling with the following clearances between the fixture and the nearest point of a storage space: (IRC E4003.12)A. Incandescent fixtures or LED shall have a minimum 12R&Rf clearance. B. Fluorescent fixtures shall have minimum 6 -inch clearance. Recessed fixtures shall be insth ftPhidge the wall or ceiling with the following clearances: A. Recessed incandescent fixtures shall have a minimum i6- inch clearance to the nearest point of storage. B. Recessed fluorescent fixtures shall have a minimum g`-'(i� y Division clearance to the nearest point of storage. 55 Working space must be provided around energized equipment for servicing and maintenance. The minimum dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the equipment. Working space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2) 56 Electrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or accumulate n wiring compartments or other electrical parts. Fixtures installed in wet locations must be labeled "suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations" or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8, E4002.9,(E4002.10, E4003.9, E4003.10,E4003.11) Plumbing Requirements 58 DWV systems shall be tested on compellation of the rough piping installation by water or for piping system other than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed .1) Water test 10 feet above the highest fitting connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes. 2) Air test shall maintain 51hs of pressure for 15 minutes. 59 Piping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1) 60 Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb threshold not less than 1 -inch below the sides and back of the receptor. The curb shall measure a minimum of 2 -inches to a maximum of 9 -inches above the top of the drain. (IRC R307, P2708, P2709) 61 The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, and lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 62 Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or CSA6125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 120'. (IRC P2708.3,P2713.3) 63 Shower doors shall have safety glazing; hinged show door shall open outward. (R308.4.5, P2708.1) 64 Backflow prevention must be provided to prevent contamination of potable water. This includes but is not limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers. Backflow device must be inspected and approved by a 3rd party agency. (IRCP2902.2, Table P2902.3, P2717) Insulation 65 R-20 Walls R-49 Ceiling R-19 Crawlspace Window U -Factor .32 Floor R-30 66 Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum R-6. ( N1103.2.1) 67 Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. (G2426.4) Class I or II vapor retarders are required on the interior side of the insulation in framed walls, floors and roof/ceilings of the building's thermal envelope. The vapor barrier is not required in construction where moisture or freezing will not damage the materials, or where the framed cavity (or space) is ventilated to allow moisture to escape. A vapor retarder is not recommended on a concrete basement foundation wall or in a shower /bath compartment (IRC 702.7, R702.7.1). Wallboard Requirements 68 The garage shall be separated from the residence and its attic by materials of not less than %-inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5 8 -inch Type X gypsum board. Where the separation is a floor -ceiling assembly, the structure supporting the separation shall also be protected by not less than %-inch gypsum board. (IRC R302.6) Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in thickness, solid or honeycomb core steel doors not less than 1 -inch thick, or 20 -minute fire -rated doors. Openings are prohibited between garages and rooms used for sleeping. (R302.5.1 )Doors between attached garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be self-closing and self -latching. 70 Nail spacing for gypsum board !/ gypum board Ceiling 16oc, 7", nails 12", Type S screws %2 wall spacing 24"OC, 8" nail spacing. 12"OCscrews. 5/8 ceiling board 16"OC, 7"nails I2"spacing, screws 240C 8". 72 Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396, C1178 or C1278. It is permitted on ceilings where framing spacing does not exceed 12 -inches o.c. for %-inch thick or 16 -inches o.c. for 5 8 -inch thick gypsum board. Water-resistant gypsum board shall not be installed over a vapor retarder in a shower or tub compartment and may not be used where there will be direct exposure to water, or in areas of contine,9,4� high humidity. All cut and exposed edges shall be sealed. (IRC R702.3.8) Wheat Ridge Building Division .. City of id Wh&at CIe OMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be up to date prior to permit issuance. G c Project Address: � i�,? � Cl c j�, �� '�,'V(',� P Permit #: General Contractor: Ct r �{ :An lC b�Vx .LG.. I Electrical Sub -Contractor I Company Name: 4 j f -:A! c_C Phone #: _% 2,0 State License #: 10/0/(o Master #: C)G Do YZ Wheat Ridge License #: % o l, 3 ``r (required field) Signature of Authorized Agent Date Plumbing Sub -Contractor Company Name: f ,G�� ,[ r UJQ Phone #: 74?y u •fig Wiz/ State License #: —Master #• Wheat Ridge License #: (required Geld) Signature of Authorized Agent Date Mechanical Contractor Company Name: Phone: Wheat Ridge License #: (required Geld) Signature of Authorized Agent Date Main Floor, ground level Kitchen Replace leaky hose valve outside of house 19' Old washer dryer Ic cation 13' -Refinish hard wood floors throughout main floor -New Kitchen Cabinets -Remove old carpet. -Demo kitchen tile floor, replace with hardwood -Replace windows to match existing sizes. -Replace existing can lights with led lights, no local -Cap plumbing at old washer location * f4" <A4& kZr in OLA Lt //c3 ` cl c ut �`"` `' v' ` Living Room Cis n; ckde on change Rear of House (West) 0 Bath #2 Bath #1 -Re-tile floor, -Replace vani • L lose®r4x,'Cl et 3cr- a 48' Front of House (East) Clos Demo tile wall ' Enclose wall Closet Bedroom #3 12.5' 4765 Saulsbury St. Closet 9.5' Bedroom #2 10' >q w )e )ICA II 26' Cr,>M P )y �-Pc Aj rr--- C City of W heat Rid9® 11uiidin S Division S Basement 4765 Saulsbury St. Rear of hni jse IIA/Pctl Egress window M Front of house (East) II is' City of Wheat Ridge Building Division - . City of Wheat Ridge E -Res. Electrical Service Upgr PERMIT - 201802138 PERMIT NO: 201802138 ISSUED: 07/31/2018 JOB ADDRESS: 4765 Saulsbury St EXPIRES: 07/31/2019 - JOB DESCRIPTION: Electrical total replacement of current 200 amp service with a new 200 amp service and installation of a new lever electrical meter installed. *** CONTACTS *** OWNER (303)422-3085 REEVES PATRICIA A SUB (720)998-2250 Ryan Underwood 180234 Mastiff Electrical Solutions *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,500.00 FEES Total Valuation 0.00 Use Tax 94.50 Permit Fee 125.05 ** TOTAL ** 219.55 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying )Tans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the original ermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable codec or any ordinanki or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 1 ; r City of COMMUNITY DEV18LOPMENT: Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax; 303-237-8929 Inspection Line: 303-234-5933 Email: permitsAci.wheatridoe.co.us Building Permit A (please prino: FOR OFFICE USE ONLY Plan/Permit # Plan Review Fee: lication Ob`S � 11(if different than property address) Address SAYVA i City, State, Zip: Mllf �i f: ; W- �T. L t 1 AMC 101 Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # mc. o('-'C)06aq Other City Licensed Sub: Other City Licensed Sub: City License # City License # 14� o b).q?31-11 ❑ COMMERCIAL RESIDENTIAL Wako.\ �r�i Ce_ r� Occupancy Type: Construction Type: Sq. FULF �) BTUs Amps Squares _ Gallons �'j (Contract value or the cost of all materials and labor included in the enure project) $ -) 00 OWNERICONTRACTOR SIGNATURF. OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Vdheat Ridge or covenants, casements or restrictions of record; that all measurements shonm and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information providei the application. -------. HAPINN: W. %: Building Division Valuation: q7&Coo'4 INSPECTION RE OARDtf INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 A Occupancy/Type Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Initials Comments Pier Plumbing Concrete Encased Ground (CEG) Mid -Roof ?j • I Foundation / P.E. Letter �,�% Lath /Wall Tie Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Initials Comments Electrical Comments Sewer Service Plumbing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Mid -Roof ?j • I �,�% Lath /Wall Tie Fire Inspection / Fire Protection Dist. Rough Electric Final Electrical Rough Plumbing/Gas Line Final Plumbing Rough Mechanical Final Mechanical Rough Framing Roof Rough Grading Final Window/Doors Insulation Final Building Drywall Screw/ Nail NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAL RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: W &L" Job Address:41 !-. > ,,�� SI - Permit Number: 2_00 i�414Cs LAT"15 W 7 ❑ No one available for inspection: Time Re -Inspection required: Yes No When corrections have been made, call fore -inspection at 303-234-5933 01"t-, Date: 1-7—inspector: jalon C. DO NOT REMOVE THIS NOTICE CITY OF WHEAT 1BIDGE }-841fding Inspecti0i Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: � � � r—u Job Address:��' L41., U� Permit Number: 01-1 ��`1 LP ❑ No one available for inspection: Time �. �� ANI�.Y Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: " DO NOT REMOVE THIS NOTICE , City of Wheat Ridge Residential Roofing PERMIT - 201704146 PERMIT NO: 201704146 ISSUED: 07/15/2017 JOB ADDRESS: 4765 Saulsbury ST EXPIRES: 07/15/2018 JOB DESCRIPTION: Residential Re -roof to install GAF Timberline HD asphalt shingles with 25 sq. *** CONTACTS *** OWNER (303)422-3085 REEVES PATRICIA A SUB (303)797-8600 Kevin Trizna 170246 M4 Roofing & Gutters *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT*: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,948.01 FEES Total Valuation 0.00; Use Tax 208.91 Permit Fee 204.30 - — �- ** TOTAL ** 413.21 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Roofing PERMIT - 201704146 201704146 ISSUED: 07/15/2017 4765 Saulsbury ST EXPIRES: 07/15/2018 Residential Re—roof to install GAF Timberline HD asphalt shingles with 25 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be pe ed is disclosed in this document and/or its' accompanying approved plans and specifications. --- - '7 [ C- _L l Signature of OWNER or CONTRACTOR Circle one) Date I 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all re uired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting a rmit shall onst d o be a permit for, or an approval of, an violation of any provision of any applicable code or any ordi It o i s fiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett From: no- reply@ci.wheatri dge.co.us Sent: Thursday, July 6, 2017 1:19 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusive) for new permits for residential roofs and for licensed pP Y p O contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. - For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be `v completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address 4765 Saulsbury St Patricia Reeves 303-422-3085 Field not completed. t q�-�.�2� Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number M4 Roofing & Gutters 170246 3037978600 Contractor Email Address laura@m4roofing.com Retype Contractor Email laura@m4roofing.com Address DESCRIPTION OF WORK Are you re -decking the No VZ roof? Description of Roofing GAF Timberline HD Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 25 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES of all 25 v/ roofing material for this project Provide additional detail Tear off and reroof - 4/12 here on the description of 2 work. (Is this for a house or garage? What is the roof pitch? Etc) 9948.01 Project Value (contract value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Rhonda Bedwell Email not displaying correctly? View it in your browser. 3 .R.1,14 Contracting, LLC 4719 S. Santa Fe Cir. Unit 2 Englewood, CO 80110 Phone: 303-797-8600 Fax: 303-797-8601 Owner VI]A'+ra - 5 Date Address 1tf Email City, State Zip J4&= Home Phone Job Location Cell Phone -�o I Z- *_50 ear Off 1 /�n 3Aers of existing shingles U Wood shake tear off ETIr 11 1 W f Synthetic underlayment Psta 6a,44t- e— AF W>stall Cer;tai rd�amko alarkey I Owens Coming 13'Shingle: IL hingle Color: stall decking (7/16" OSB) 154ck tke--(.b J Jlnstall Ice and Water shield 13 Install new step flashing: Col br: Black / Grey /81r40 Mill ffinstaill new drip edge on rakes Color: '-w--rr White / Other: nn Install new drip edge on eaves Color:'\Brown YWhite/Other: Install new roof vents Paint roof vents and stacks to blend with g e calor Nail & seal new pipe flashing and van Clean up & remove debris Magnetize yard for nails Clean gutters Provide local building permit Manufacturer's warranty based on which shingle is installed ET Provide a 60 -month installatio warranty. (Not valid until account is paid in full) Approximate Dates of 1 71"', 4— 1 R Gutters: Gutter size: 5- 06- 0 Replace AI(3OthE Total Gutter Length: ' LF Total Downspout Length: LF Downspouts: [32"x3'-C13"x4"[3Replace AI(30thf ti Color. Instructions: SYSTEMS PLUS / GOLDEN PLEDGE See addendum approximate costs of the services based on damages known at the time this contract is entered is $ Contracting, LLC, however, will perform the scope of work approved by the insurance company for the amount'dT the insuranc roved proceeds, with no additional cost to you except for your. deductible. The final scope and price agreed on between th iranee company and M4 Contracting, LLC shall become the final contract price for the insurance approved scope. You will b )onsible to pay for any upgrades or additional work authorized by you that the insurance company determines is not covered withi scope of coverage provided by your insurance policy. Supplemental claims billed by M4 Contracting, LLC that are approved by th iranee company for additional work or increases in cost become a part of this contract. 'hen the insurance company and M4 Contracting, LLC agree upon a price, that amount will be the final contract amount and )ntracting, LLC will install the roof. M4 Contracting, LLC will receive all insurance proceeds for the work completed by M4 Contracting, the insurance company does not approve the roof replacement, en m this contract is null and void. M4 Contracting, LLC shall hold in t iy payment from the property owner until the roofing e have been delivered to the jobsite or has performed a majority of iofine work. " I r - -7- M4 C rntracting, LLC Representative Date We may withdraw this proposal if not accepted w/m 10 days. Acceptance of Proposal - M4 Contracting, LLC is authorized to do the work as specified in the TERMS above, Owner/Authorized Agent Date I have read and understand the terms and conditions listed on the back side of this page. Homeowner Initials: ♦ CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office,' (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type PF-C ffo ZF',E: Job Address M_ < 7 Permit Number !lr t ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes When corrections have been made, call for re- inspection at 303 - 2345933 Date: ?IJr Inspector f C DO NOT REMOVE THIS NOTICE City of Wheat Ridge / Residential Mechanic PERMIT - 110214 PERMIT NO: 110214 JOB ADDRESS: 4765 SAULSBURY ST DESCRIPTION: Replace 135,000 btu boiler ISSUED: 03/07/2011 EXPIRES: 03/06/2012 * ** CONTACTS * ** owner 303/422 -3085 Patricia Reeves sub 303/422 -6073 Leon Gonzales 06 -0027 Best for Less Heating &Cooling ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0801 - BLOCK /LOT##: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 4,500.00 FEES Permit Fee 40.00 Total Valuation .00 Use Tax 81.00 ** TOTAL ** 121.00 Conditions: Work shall comply with 2006 IRC & 2005 NEC. Per IRC Sec. R313, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. Carbon Monoxide detectors are required to be installed within fifteen(15) feet outside the entrance to each sleeping room. Subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and /or its'Laccompanying approved plans and specifications. Signature of OWNR ACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. S. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspec ion. Signature f Building Offical - Date INSPE ION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Cit of W h eat heat �Ce Date: CONLMUNriY DEVELOPMENT Plan # Building & Inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Permit # j21 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303- 234 -5933 Building Permit Application Property Owner (please print): ��I RtC tali, Phone: > <122^ 305 Mailing Address: (if different than property address) Address: City, State, Zip:, t 0071taCtQ11: Contractors City License #: Phone: ul�ontracto7s� "; "; Electrical: Plumbing: Mechanical City License # City License # City License # Dessrtpttort of �uorka wsrW (t`;c tAr r✓xtsT >t xt s3otl��tL.. I' (gyp Contract Value: 5t7 $ 6 to , n Review Fee (due at time of submittal): Squares BTU's Gallons Amps Sq Ft. $ OWNER /CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: 022 t�0WZP)4 % SIGNATO DATE; QLI___ 701JJNGCOMMEN�TS ,/ v - ✓i" <.r��r ✓r�r�P /''i r ,.N � � � �"r i- �F`.�,r�`asl'r<,. ^�"yw.arr.�sr""`,3 fret ° � r ��� ,+ t � .Y. z. " ,'.� rr' ? e ,+ �' "`. Y e A7✓ 2CY <„ �r` ?`r'`r G ?a ,fi ,� y r r� � ,.� > c am; , . .�'' j ZOringa � /J-f . ��`+"rsNry'r y S�tr .;s _; �alr�c ��� �s'u xr r G � r /.*�i�irr'G.% s3;�RCYIOWeieh�rso �ti r"3jr rs3.u`lr��rr. cyr�r w�; vr���I�� � ✓�u^icvsi ✓cam >>r�h�fid�r�Ora ��r i''t 1. r^ �r,. �`��c -c .i . l+"y ,fir /i vl"�✓"'- :i r.�, f r i" ,S �ti.'� ✓ � X3"2 r' � ✓'�' l✓ t// is �� +'� . f I3YIILDf NGDE �R (�1 r a ��/ r r h- �f?r�r ��rt r� K r �, rri rrtrtaJy� £'r : J ✓ ✓✓' RevleyveJ' � ✓ y ✓"Yi ra� rP Fr � r Gr r r r�rr� j `�, ca/ ✓a � ^fs y� ✓r� � J � y rr rr � fi r. i, l 3 w: r /`�'`r/,U�rAS ..%. xG� i � F r � t �r..rr -✓ r�� �" tix .t � /' i .-!> i'i",� r'' %`?, C , r /' I y. s ' � r � ham, r N ., '/ ;! �`^rr'rr. ^r. r!'rlY ./' / ✓ ir � �r� t� ��3'� �Y s� �"��✓r�� ✓rF c :513 rM rS�� ,r �' � � � �� /„ � �rl] f�5 kr*i i 4Fj /r Y� 1( r r �7 > w e 7 "a + K /r �� ✓'�y7� J i %r, �S -'. w„1r?t Ii �r/y -; sr %�? Fr�rT ✓rf�r':! 's � r'3 rr a?� l r� r'?yG��,- t�ti'Gl'o��1��� 3�„r.+�o- "�""1..��'�2r `'�v�� r ri >'' r PUBLIC WORjCS COM ENTS �b a'c' ✓ G e"r �C"r ✓ 't - "��,+>> 8 � �.r'x . r � �. ! '7t -1 tr r a r; a ✓, .✓� ,r l�r: y OCCUP ✓ AflGY > /'� � a r°rr., rFr >a /%r.., a1 a .-' r r / ✓ r-C rr.." r..r`a < s l.rr f ReV18W�[' rr rr� f r�r � � r � 4 y �f /� 3 > g ✓zv;'%r / r �r �j ✓ /ra ✓� � ✓ r r > i t-7RE DEPARTMENT r r r rr�, ac s � a r ✓ l � r o ;-r �, .p approvgd,.w/ cornment�s ❑ disapproved r �t7 �y rey��ew'regUr recd Bidg Valuation. $