HomeMy WebLinkAbout4765 Saulsbury StreetEGRESS WINDOW INSTALLATION APPROVAL
Job No. WWM98-21790
Date Signed: November 15,
ItISWell Windows and Egress
17059 E. Wiley Place
Parker, Colorado 80139
Attention: Trevor Nicola
Re: Egress window for the residence at:
9765 Saulsbury St., Wheat Ridge
Dear Mr. Nicola
On this date Crown Jade Design and Engineering
personnel or representative under my supervision and in
direct contact with me observed the structure of the
egress window, with a U value of 0.28, per the detail on
file at the project site. The egress window as designed
was installed satisfactorily as was the liquid applied
flashing membrane Quad Flash by OSI to seal the openings.
Thank you for retaining our firm to perform this
structural evaluation service.
Very truly yours,
DOUGLAS INGERSOLL, EI, BSME
MARK BENJAMIN, PE, MSCE, SECB, CPHC
{Certified in the practice of structural engineering}
Certified Passive House Consultant
Copies: (2) To do our part to save resources:
Provide both to your contractor for distribution, or
provide one photocopy to the homeowner for their records.
Contact our office for an electronic version to be emailed to
you if so desired.
Engineered for the way you build ...
... Designed for the way you live.
IN ME EXISTING CONCRETE FOUNDATION
CUT A HORIZONTAL SLOT FOR TUBE STEEL
PLACEMENT = R O + 9" WIDE X ZDEPTH.
CUT HORIZONTAL AND VERTICAL ROUGH
OPENINGS • 3" FOR MMMING ALL SIDES
INFILL BETWEEN NEW HUS HEADER AND
NEW WINDOW AS REQUIRED. THE NEW
WINDOW LOCATION MAY BE ALIGNED
WITH BOTH SIDES OF THE EXISTING
WINDOW.
NOTES
• TEMPORARY SUPPORT 5 REQUIRED
ON ALL LOAD BEARING WALLS PRIOR
TO DECONSTRUCTION
• WINDOW WELL SHALL BE 9 N]. F.
MIN. AREA WITH BE MIN,
CLEARANCE FROM FOUNDATION
WALL TO INSIDE OF WELL.
• A PERMANENT LADDER 6 REQUIRED
IN ME WINDOW WELL IF B070M OF
WELL IS M" OR MORE BELOW GRADE.
• IN CASES WHERE ME NEW EGRESS
WINDOW'S R.O. IS LESS THAN OR
EQUAL TO THE EXSTING WINDOW
WIDTH. THE EXISTING HEADERILIMEL
IS SUFFICIENT TO SUPPORT THE
MAXIMUM DESIGN LOAM IMPOSED.
NO ADDITIONAL SUPPORT REQUIRED.
• FILL GAPS BETWEEN NEW HSS AND
CONCRETE WITH MORTAR OR NON
SHRINK GROUT
• DRAINAGE TO EXISTING FOUNDATION
DRAINAGE SYSTEM REQUIRED
• GENERAL AREA WELL CODES APPLY.
REFER TO IRC R310.3.2
IF PRESENT, EXISTING STEEL LINTEL AT —
BRICK VENEER i0 REMAIN. OTHERWISE.
BRICK i0 BEAR ON NEW HTS$ HEADER
III V T Vies MIN.
ENSURE CONCRETE CONTACT ON TOP
CN SLOT Be ED REARING.
MIN, TYPICAL BOTH ENDS.
MORTAR INFILL OF LOOSE
CRUMBLED CORNERS
REQUIRED BUT NOT
CONSIDERED STRUCTURAL AS
PART OF F BEARING
These Letter all ressawal anal the Kable
laws in i at the else & wants Rental
LHw 'Hall H these Eatal still 11 01
skeeter W View nflo�weale�, als,nalat
RRY seensishinThai
Qty: (1) 30" x 48"
Location: Basement West wall
Type: Casement
U Value: .28
At existing window YES
Existing lintel or header YES
Window above YES
Floor joist bearing YES
Brick Veneer
al TOUTS AND DECKING
STREET ADDRESS:
N
crown jade
4765 Saulsbury St.
JOB IF
TOP OF V UK.
FOUNOAOON
S\
Wheat Ridge
EXISTINGWINDOW
WWAE98-21740
DESIGN AND ENGINEERING
------------
TP
4165 OLITTENiON LN.:
09,1WELLINGTON
R.O.+S'•
O
SCALE: NONE
SHEET
(970)471-2399
'VERIFY DIMENSIONS
1N
1 01G
WITH WINDOW
wrm.crovmjaaemm
MANUFACTURER, AND
1
ADJUST SAWCUT
yCLUB CALU
DIMENSIONS IF
TRIMMER
REQUIRED.
y
PLACEHORI ONTAIi
NAILER SILL SNUGLY
sc 0
BETWEEN VERTICAL
EPC
NNLERS.
rq 2
an
a
E\A/ 2'1-X4'4 EGRESS WINDOW OPENING - INTERIORMIN,
Y♦ SCALE: NONE
I Mark Benjamin P.E. have observed the
proposed installation and determined that
this detail meets existing conditions.
Building Code: 2018 IRC/IBC '�A -% I
Roof Snow: 30 psf tewawa° R
Ground Snow: 30 psf
Nominal/V-U1t. Wind Speed: 135 mph; 3 sec. gust. DEC. C
Seismic Design: Category B
PHINDILE, Me 0II
STREET ADDRESS:
ENGINEER'S
crown jade
4765 Saulsbury St.
JOB IF
Wheat Ridge
WWAE98-21740
DESIGN AND ENGINEERING
4165 OLITTENiON LN.:
09,1WELLINGTON
Me 80522-0011
SCALE: NONE
SHEET
(970)471-2399
1N
1 01G
CHECRBBYBY:IMB
wrm.crovmjaaemm
1
From: no-reolv(alci.wheatridae.m. us
To: CommDev Perm is
Subject: Online Form Submittal: Residential Egress Window Pennit Application
Date: Tuesday, October 5, 2021 10:38:54 AM
Residential Egress Window Permit Application
This application is exclusively for RESIDENTIAL EGRESS WINDOWS ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORMAN D
ENGINEER LETTER STAMPED DETAIL SHOWING THE U -VALUE OF THE
WINDOWCUT IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit
will be emailed to the email address provided below once it is processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for Yes
existing EGRESS
window(s) needing
vertical cuts only?
PROPERTY INFORMATION
Property Address 4765 Saulsbury St.
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address - Do not enter
a contractor email
address
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
Lycel Teed
1918191-010101.1 [till
Thomasteed@yahoo.com
Saulsbury St Payment Form.odf
CONTRACTOR INFORMATION
Contractor Business Mosley & Boyd Construction
Name
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Person Applying for Dion Mosley III
Permit
Email not displaying correctly? View it in your browser.
Contractor's License
210210
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
Contractor Phone
7208228131
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
dmosley@mbconstr.com
Address
Retype Contractor
dmosley@mbconstr.com
Email Address
01 :K161 Ci 191 [*] 0 N] avOLe] N :/
Number of EGRESS 1
windows being
replaced
Location of EGRESS Basement
window(s) being
replaced (for example,
master bedroom,
kitchen, bathroom, etc):
What is the u -value of 0.28
the EGRESS
window(s)? City of
Wheat Ridge requires
the u -value to be .30 or
better on windows.
Attach copy of 21-098-1-4765 Saulsbury St -Wheat Ridge -SIGNED Ddf
Engineer stamped
letter showing vertical
cuts detail and u -value
Project Value (contract 3950
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
� ► � i City of Wheat Ridge
Residential Remodel PERMIT - 202101111
PERMIT NO: 202101111 ISSUED: 06/25/2021
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 06/25/2022
JOB DESCRIPTION: Adding a kitchenette, plumbing work will be done to add a kitchen sink,
hook up appliance like dishwasher. Add electrical lines for kitchen
appliance and add a hook up to washer. No wall will be removed or added.
180 sq ft
*** CONTACTS ***
OWNER ( 72 0) 731-8624 TEED LYDIA CECILIA
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 15,410.00
FEES
Total Valuation 0.00
Plan Review Fee 194.61
Use Tax 323.61
Permit Fee 299.40
** TOTAL ** 817.62
*** COMMENTS ***
*** CONDITIONS ***
All roughs to be done at Framing Inspection.
A printed copy of the permit and city stamped on-site plans must be available on-site for
the first inspection.
Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
NOT APPROVED AS AN INDEPENDENT OR ACCESSORY DWELLING UNIT.
1* ► � i City of Wheat Ridge
'/� Residential Remodel PERMIT - 202101111
PERMIT NO: 202101111 ISSUED: 06/25/2021
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 06/25/2022
JOB DESCRIPTION: Adding a kitchenette, plumbing work will be done to add a kitchen sink,
hook up appliance like dishwasher. Add electrical lines for kitchen
appliance and add a hook up to washer. No wall will be removed or added.
180 sq ft
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
�pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
06/25/2021
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
MMW neat �L ge
64 L�
state alichow3wip
cwbmya� Its
12ft onlyNOTA�ROVED AS AN
Ir
I'o
`
Kitchenette
�
1
-
p
4
t,¢
_NL
C
°'#ttR
SMOKE ALARMS AND CARBON MONOXIDE DETECTORS TO COMPLY WITH
2018IRC R314 AND R315. SMOKE ALARMS SHALL BE INSTALLED IN EACH
SLEEPING ROOM, OUTSIDE OF SLEEPING AREAS, ON EACH STORY, AND BE
INTERCONNTECTED. CARBON MONOXIDE ALARMS OUTSIDE OF EACH
SLEEPING AREA IN THE IMMEDIATE VICINITYOF THE BEDROOMS.
COMBINATION DETECTORS ARE PERMITTED.
All work shall comply with the 2018 IRC, 2020 NEC and City Municipal Codes
12'
275 27" 29 5"
MICROWAVE +STORAGE
01 r 2'
KITCHENETTE DESIGN
GENERAL FLOOR PLAN
7/8"
5'
10,
Ch or
'(KWQ- t N ici *e'
"REVIEWED FOR CODE COMPLIANCE"
These drawings were reviewed under the applicable
laws In effect at the time of submittal. Reasonable
effortwas exercised In checking for cod=_ compliance.
The stamping of there documents shall not be
construed to be a permit for, or an approval of any
violation of state and/or local codes, ordinances or
amendments thereto.
Plan Reviewer Sones
Date 06/22/2021
-Fire Blocking and Draft Stopping shall be installed in
concealed spaces per R302.11 & R302.12.
-Minimum Ceiling height shall be 7' or accordance with
section R305.1.1.
-Smoke Alarms shall comply with R314.
-Carbon Monoxide Alarms shall comply with R315.
-Kitchen exhaust hood systems capable of exhausting
in excess of 400 cfm shall be provided with makeup air
at a rate equal to the exhaust rate per code M1503.4
and City Amended Code.
-For new fuel gas appliance please provide to
the inspector at the time of rough inspection an
isometric fuel gas piping diagram. The fuel
piping diagram shall include the existing fuel
gas piping as well as the new fuel gas piping.
The calculations shall be for the complete fuel
gas system per code section G2413.
1) Minimum net clear opening area: 5.7 sq. ft. or
5.0 sq. ft. at grade floor or below grade
2) Minimum net clear opening height: 24"
3) Minimum net clear opening width: 20"
4) Maximum sill height: 44"
From: no-reolv(alci.wheatridae.m. us
To: CommDev Perm is
Subject: Online Form Submittal: Residential Interior Remodel
Date: Tuesday, May 25, 20212:08:30 PM
Residential Interior Remodel
This application is exclusively for Residential Interior Remodels and other scopes
of work which do not have a specific form already available.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Property Address 4765 Saulsbury St Wheat Ridge Colorado 80033
Property Owner Name Thomas Teed
Property Owner Phone 720-731-8624
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email Thomasteed@yahoo.com
Address
Attach City of Wheat BOB97534-FA3E-49DD-8EA5-45B3BDF09419.ioe
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
APPLICANT INFORMATION
Applicant Name Thomas Teed
What is your role in the Property Owner
project?
Are you performing the Yes
work yourself, live in
the home and will be
living in the home 1
year after completion?
Attach Notarized
Homeowner
Authorization Form
Contact Phone Number
(enter WITH dashes,
eg 303-123-4567)
Contact Email Address
for Plan Review
Comments
EDD20D47-A79D-434E-BEFC-ODE8589A6D44.ioea
720-731-8624
Thomasteed@yahoo.com
Retype Contractor Thomasteed@yahoo.com
Email Address
DESCRIPTION OF WORK
Detailed Scope of
Work - In the space
below (not as an
attachment), Provide a
detailed description of
work including
mechanical, electrical,
plumbing work
occurring,
adding/removing walls,
etc
I, the applicant,
understand my
application will be
rejected if I do not
include a Detailed
Scope of Work.
Adding a kitchenette, plumbing work will be done to add a
kitchen sink, hook up appliance like dishwasher. Add electrical
lines for kitchen appliance and add a hook up to washer. No wall
will be removed or added.
I have entered a detailed scope of work.
Location of Work Basement
Square Footage Area 180
of Work Being
Performed
Asbestos Report Field not completed.
Upload letter size Field not completed.
documents here
Construction Plans Kitchenette floor. pdf
scanned on 11'x17" or
larger
Project Value (contract 15000 15,410.00
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
Person Applying for Thomas Teed
Permit
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Email not displaying correctly? View it in your browser.
MMW neat �L ge
64 L�
state alichow3wip
cwbmya� Its
City of Wheat Ridge
E -Res. Evaporative Cooler Repl PERMIT - 202001610
PERMIT NO: 202001610 ISSUED: 08/17/2020
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/17/2021
JOB DESCRIPTION: Replacing evap cooler, 5500 CFM on roof.
*** CONTACTS ***
OWNER (303)999-8130 TEED TOM
SUB (303)422-5308 STEVE BRANDT 021365 THE COOLER COMPANY
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,000.00
FEES
Total Valuation 0.00
Use Tax 105.00
Permit Fee 125.05
** TOTAL ** 230.05
*** COMMENTS ***
*** CONDITIONS ***
Both the front and back of this permit are required to be posted on the job site at all
times. If the complete permit is not present, inspections WILL NOT be performed.
Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section
134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of
which require a building permit, occurs or where one or more rooms lawfully used for
sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen
feet of the entrance to each room lawfully used for sleeping purposes.
City of Wheat Ridge
E -Res. Evaporative Cooler Repl PERMIT - 202001610
PERMIT NO: 202001610 ISSUED: 08/17/2020
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/17/2021
JOB DESCRIPTION: Replacing evap cooler, 5500 CFM on roof.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications;
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, T. ' uance or gra ti g of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
r
1... ble ode or ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dina Kemp
From: no-reply@ci.wheatri dge.co.us
Sent: Friday, August 14, 2020 1:50 PM
To: CommDev Permits
Subject: Online Form Submittal: Air Conditioner/Evaporative Cooler Permit Application
Categories: Dina
Air Conditioner/Evaporative Cooler Permit Application
This application is exclusively for AIR CONDITIONER OR EVAPORATIVE
COOLER.
YOU MUST ATTACH THE ELECTRONIC PAYMENT FORM IN ORDER FOR THE
PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Is this a new install or
replacement for an
existing AC unit?
Is this Residential or
Commercial?
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Attach City of Wheat
Ridge Electronic Payment
Form - **DO NOT
ATTACH A PICTURE
OF A CREDIT CARD**
Replacement of Existing Unit
Residential
4765 Saulsbury St
Tom Teed
303-999-8130
thomasteed@yahoo.com
Wheat Ridge payment form.pdf
CONTRACTOR INFORMATION
Contractor Business
Name
Contractor's License
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-4567)
The Cooler Company
021365
303-422-5308
Contractor Email Address lori@thecoolercompany.com
Retype Contractor Email lori@thecoolercompany.com
Address
DESCRIPTION OF WORK
What type of replacement Evaporative Cooler
unit are you installing?
How many tons is the It's a cooler not ac
unit?
For AC - what is the 5500 CFM
SEER?
For Evaporative Coolers,
what is the CFMs?
Where is the unit located Roof
(for example, rooftop,
backyard on ground etc)?
Is electrical needed for re- Yes
hook?
Provide Electrical 021365
Contractor's Wheat Ridge
License No.
Project Value (contract 5000
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
2
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for Kim Earnheart
Permit
Email not displaying correctly? View it in your browser.
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:_ ["Cn)
Job Address: t 7 '7 4 P"
Permit Number:"
❑ No one available for inspection. Time
Re -Inspection required: Yes, No
When corrections have been made, call for re -inspection at 303-234-5933
Date Inspector: 'Y�
DO NOT REMOVE THIS NOTICE
i
CITY OF WHEAT RIDGE
Building Inspection Division
�(303)
(303) 234-5933 Inspection line235-2855
Office • (y33003) 237-8929 Fax
',
`f'/of -13 Z:;;Pi
INSPECTION NOTICE
Inspection Type:
�75_ fC r
Job Address:
Permit Number:l
n /
❑ No one available for inspectiom. Time I L `SAM/P
Re -Inspection required: Yep No
When corrections have been made, call for re -inspection at 303-234-5933
Date: 9, % + Inspector: --
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
I SPECTIO NICE
Inspection Type:
Job Address: __- u Zia f Z-2%
Permit Number:''
❑ No one available for inspection: Time
Re -Inspection required: Yes 16-0111-)
When corrections have been made, call for re -inspection at 303-234-5933
Date: 2!5�A-' " l`� Inspector: j�-----
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: Vo) I e c IV : c6l
Job Address: ` NoN ' 5 -
Permit Number: '101 � o d l
❑ No one available for inspection: Time CXIVy AA PM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303 -234 -
Date: _Inspector: ! r
DO NOT REMOVE THIS NOTICE
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: (�
Job Address: C'
Permit Number: j
/--
❑ No one available for inspection: Timer` . ;MPM
Re -Inspection required•'/ 0
When corrections have been mad cad 11 fort-ir�peetienat 303-234-5933
Date. `Z.-GQnsppecto .
i
I
DO NOT RE' E THIS NOTICE
i CITY OF WHEAT RTOGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address: SE 5f <
Permit Number:
❑ No one available for inspection _,13,mper�7 _y
Re -Inspection required: Yes
When corrections have been made, call for re -inspection at 303-234-5933
Date:e/ 91 z^ inspector: --
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: Jy ` fir, �i t✓t �f =` r i/Nrid
Job Address: `!6 s
Permit Number:
❑ No one available for inspection: Time r,� PM
Re -Inspection required: Yes /NO)
When corrections have been made, call for re -inspection at 303-234-5933
-.r
Date: /,, / i�, Inspector: Done (el -e r4t
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
�Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number: ' fl
LlNo one available for inspection: Time `! , 6 'A'") PM
Re -Inspection required: Yes ,Na
t.,.�"
When corrections have been made, call for re -inspection at 303-234-5933
Date: ` f Inspector: i�,� rnId
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION- )NOTICE
� � 1
Inspection Type: �r'C� -��n ff _ // !{
�Ji %C.('(i`GL" .
Job Address: _jsi ' J
Permit Number: l' f), f'O_� "S(
'r -
Ll
❑ No one available for inspection: Time 0. r) 5 AIM�PM
Re -Inspection required: =/1( �' No
When corrections have been made, call for re -inspection at 303-234-5933
i
Date: t z / ` Inspector: s evL C,
DO NOT REMOVE THIS NOTICE
® ! s_ CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: 3 13- _ � r�� �X �� � % ��� �, k �' 4�r: n; err
Job Address: ?o 5-
Permit Number:.
❑ No one available for inspection: Time
Re -Inspection required:SYe 1 No
,__
When corrections have been made, call for re -inspection at 303-234-5933
1:
Date: %' ' Eft Inspector: 'rl_ Gvf -
DO NOT REMOVE THIS NOTICE
Kimberly Cook
From: Juan Alvidrez <JARplaza@msn.com>
Sent: Friday, November 30, 2018 10:23 AM
To: Kimberly Cook
Subject: 4765 Saulsbury st
Kim,
Please update the list of employees can pull permit from Plaza Construction new list is Juan Alvidrez, Flor Alvidrez and
Cynthia Alvidrez. Thank you please cancel the permit that was issue for 4765 Saulsbury st Wheat ridge 80033. Thank
You!
Juan Alvidrez
President
Phone: 303-573-0190
Fax: 303-623-0631
www.MvPlazaConstruction.com
Our Facebook page
City of Wheat Ridge
Residential Roofing PERMIT - 201802231
PERMIT NO: 201802231 ISSUED: 08/09/2018
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/09/2019
JOB DESCRIPTION: Reroof and Redeck House back patio remove and install Certainteed
Flintastic GTA Modified Rolled Roofing System with 3.75 squares. Pitch
1.5/12.
*** CONTACTS ***
OWNER (303)422-3085 REEVES PATRICIA A
SUB (303)438-1007 Doug Breinig/Melodi Breinig 140189 J&N Roofing Inc.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,000.00
FEES
Total Valuation 0.00
Use Tax 42.00
Permit Fee 77.50
** TOTAL ** 119.50
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
City of Wheat Ridge
Residential Roofing PERMIT - 201802231
PERMIT NO: 201802231 ISSUED: 08/09/2018
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/09/2019
JOB DESCRIPTION: Reroof and Redeck House back patio remove and install Certainteed
Flintastic GTA Modified Rolled Roofing System with 3.75 squares. Pitch
1.5/12.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, an violation of any provision of any
applicable code or any orcr�}ance or regulation of this jurisdiction. Approval of work is subject to f any
inspection.
tea- e
Signaturew of Chief 13ilding Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Lagenia Reimer �a t rO 0 2 2--,,
From: no-reply@ci.wheatridge.co.us
Sent: Thursday, August 9, 2018 3:50 PM
To: CommDev Permits
Subject: Online Form Submittal: Residential Roofing Permit Application
Categories: Gina
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. The Building Division permit counter is open from
7:30 am to 3:30 pm, Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
4765 Saulsbury St
John Jaen
720-765-0549
c -e
Property Owner Email
Address
Do you have a signed
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
johnjaen@gmail.com
Yes
Attach Copy of Executed JN roofing 4765 saulsbury signed contract.pdf
Contract
CONTRACTOR INFORMATION
Contractor Business J&N Roofing
Name
Contractor's License 140189
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone 303-438-1007
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address 1180 S. Balsam St.
(Primary address of your
business)
Contractor Email Address jnroofing1 @comcast.net
Retype Contractor Email
Address
DESCRIPTION OF WORK
TOTAL SQUARES of
the entire scope of work:
Project Value (contract
value or cost of ALL
materials and labor)
Are you re -decking the
roof?
Is the permit for a flat
roof, pitched roof, or
jnroofing1 @comcast.net
375 square ft
2000
Yes
Flat roof (less than 2:12 pitch)
z
both? (check all that
apply)
What is the pitch of the
FLAT roof?
How many squares are
part of the FLAT roof?
Describe the roofing
material for the FLAT
roof:
Type of material for the
FLAT roof:
Provide any additional
detail here on the
description of work. (Is
this for a house or
garage? Etc)
1.5/12
375 sq ft.
Certainteed Flintastic GTA modified rolled roofing system
TPO/EPDM
House Back Patio flat roof only
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
3
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for Nathan Breinig
Permit
Email not displaying correctly? View it in your browser.
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: 3 c 8- R o A f f -ec
Job Address: '-)-71'S- S a u is va-w 07L
Permit Number: a o i 8 0 a a 4)
❑ No one available for inspection: Tirr
Re -Inspection required: Yes
When corrections have been made, call for re -inspection at 303-234-5933
DateC----h)spect_ :.
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
_1�9�Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: -30 X E
Job Address: y Sgv1S ver
Permit Number:
/V/-) AmtI�VrD(v
w I-
14 h 4/, 0j;4 5 a1 P 4, 4rj,
f
0fi r/P '� t
�aiq % Cl
e
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Ye;> No
When corrections have been made, call for re -inspection at 303 -234 -
Date: q �� iii Inspector: %%i T#
DO NOT REMOVE THIS NOTICE
Y-4--
CITY OF WHEAT RIDGE
Building Inspection Division,
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: _-w C h P � 0 OA Q
Job Address: 477 L Scw i bu�� gf
Permit Number: _ ao I ?C)02 (0
r
J t /►
1 J/
1
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303 -234 -
Date:— R f Inspector:
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
jA Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: t V1
Job Address: 4'i (OS- 451�L'a (50v r
Permit Number: '26/k® ( 3Fr
❑ No one available for inspection: Tina" AM/PM
Re -Inspection required: Yes t;No�i
When corrections have been made, call, for ri_e' ct on at 303-234-5933
gip" f
Datef ` t Inspect"o�!-____ DO NOT NOT REM01VE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: M_04eJ1 F_ -- L
Job Address: q:j f6U U V
Permit Number: o2D1'�6k)ZI S6 I
❑ No one available for inspection: Ti M PM
Re -Inspection required: Yeso �
When corrections have been ma" e,_ cal -inspection�at2303-234-5933
Date Ins eir�
DO NOT REMOVE THIS NOTICE
A i CITY OF WHEAT RIDGE
Building;
A City of Wheat Ridge
`rr Residential Remodel PERMIT - 201802261
f�
PERMIT NO: 201802261 ISSUED: 08/21/2018
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/21/2019
JOB DESCRIPTION: Remodel of main level and basement - 2,620 sq ft total; Main Level: new
flooring, new kitchen cabinets, bathroom vanities; adding a shower in
upstairs existing closet; replace windows -1,310 sq ft; Basement level: new
drywall ceiling, finish roughed -in bathroom, new LED lights, fur out and
drywall two walls in both bath and office; 2 new egress windows - 1,310 sq
ft
*** CONTACTS ***
OWNER (720)765-0549 JAEN JOHN
GC (303)573-0190 Juan Alvidrez 090253 Plaza Construction
SUB (720)998-2250 Ryan Underwood 180234 Mastiff Electrical Solutions
SUB (720)361-0200 Rashad Gordon 180259 Pipe It Up
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 40,000.00
FEES
Total Valuation 0.00
Plan Review Fee 399.46
Use Tax 840.00
Permit Fee 614.55
** TOTAL ** 1,854.01
*** COMMENTS ***
*** CONDITIONS ***
All roughs to be done at Framing Inspection.
Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
City of Wheat Ridge
Residential Remodel PERMIT - 201802261
PERMIT NO: 201802261 ISSUED: 08/21/2018
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 08/21/2019
JOB DESCRIPTION: Remodel of main level and basement - 2,620 sq ft total; Main Level: new
flooring, new kitchen cabinets, bathroom vanities; adding a shower in
upstairs existing closet; replace windows -1,310 sq ft; Basement level: new
drywall ceiling, finish roughed -in bathroom, new LED lights, fur out and
drywall two walls in both bath and office; 2 new egress windows - 1,310 sq
ft
I, by my signature, do hereby a st that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable uildi codes, an al applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal ow of the pro a and am authorized to obtain this permit and perform the work described and approved in conjunction with
this pe rt. I fu er attest t at am legally authorized to include all entities named within this document as parties to the work to be
perfb and t all wor to a perf" med is disclosed in this document and/or its' accompanying approved plans and specifications.
Alfiadrn NA&N 211( fi
Signature oT7VVXER oD ZONTRACTOR irclefone) Date
1. This per ed on the ipforn ion provided in the permit application and accompanying plans and specifications and is
subject to eet pliance w� ents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This perrm , s a 1 expire 365 days a the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or grant' of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
app ale code or an rdinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of'
Or Wheat j
COMMdgc
UNITY DEVELOPMENT
Building & Inspection Services Division
7500 W. 2911 Ave., Wheat Ridge, CO 80033 43
Office: 303-235-2855 " Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: perm its(fti.wheatridge.co.us
FOR OFFICE USE ONLY
Date:
Plan/Permit # '�c
Plan Review Fee:
Building Permit Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications
may not be processed. ***
�
Property Address: i-12� W1S
Property Owner (please print): 76 _T�L& Phone: ® (
Property Owner Email: Tal -01
Tenant (Commercial Projects Only)
Property Owner Mailing Address: (if different than property address)
Address: ro a 00 W ; 2 a V11'_ d
City, State, Zip: ui�kka4 iz4 ctaf _ 66&� 3
Architect/Engimers C_&_�LU Lj__�
UJ
Architect/Engineer E-mail: � ao , (6 Phone:
Contractor: 94 4 iku
City of Wheat Ridge License #: Phone:G�
Contractor E-mail Address: V )� ) X11 d �-e 70a AA, J -W ��� lLf i%l5`�Y�,C il✓t . VA
For Plan Review Questions & Comments (please print):
(p print): &L)�' o �C
CONTACT NAME lease rint : l✓ hone:
CONTACT EMAIL(p/ease
Cv
J oV� r� j cue V� E' '*- u i t ,
Sub Contractors (Must provide Wheat Ridge License�V0.):
Electrical:t{rG't i"jC Plumbing: �t i ! k %C Mechanical:
W.R. City License 1�j22 W.R. City License # i.� W.R. City License #
Other City Licensed Sub: Other City Licensed Sub:
City License # City License #
C_ --c `'L J
❑ COMMERCIAL
[glt'ESIDENTIAL
Description of work: For ALL projects, provide a detailed description of work to be performed,
including current use of areas, proposed uses, square footage, existing condition and proposed new
condition, appliance size and efficiency, type and amount of materials to be used, etc.
UernoK-tb,n "t Kktl �., I bA:,room- 4Lc %. mat Rr. ail did cQ rpcf 1 re,6V t- L
I•��rv\woz:�w �Q�iravJS tn�lvd� 2w e�f-csj ✓L�I�wS .
rJ V_V�r. �tvA{S ( IJe1-kroan,_ ✓i- ALttjeS .
�Ic-r�cs.� �can.l v(Jyd� , rt t -cd.
PI .�� : w\ 1 t, • gln�,� t r �.p5 (5 -eye 41' 1 C_'o S�C-"{_ ,
.I
►��( �`n j �'.I,l trvau�-�,� �v. ��`n.�l t -� l�c� `,� ►�.c�4^�°ori
WQ-t�� Co
Commercial ProjectsOnly: Occupancy Type: ! ns tion Ty
Sq. Ft./LF 64" t t'tTus Gallons
Amps
Squares
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
5
ofi(�tC—C
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provided on the app ca ion.
CIRCLE ONE: (OWNER) (CO R) or (A T ORIZED REPRESENTATIV of (OWN) (CAN/T CTOR)
T
Signature (first and last name): j) � / � � DATE: / �( _/y
Printed Name: �` " a -I l l t u i/10l.Ci OL
DEPARTMENT USE ONLY
ZONING COMMMENTS: OCCUPANCY CLASSIFICATION:
CONSTRUCTION TYPE: I
Reviewer:
BUILDING DEPARTMENT COMMENTS:
_ 1
Reviewer: f 1
PUBLIC WORKS COMMENTS:
Reviewer J,
Building Division Valuation: 9 0, V 0 0
City of See attached list for additional requirements that
W heat I�dge apply to this project.
COMMUNITY DEVELOPMENT
City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929
Review is limited to the contents of the plans submitted and any errors or omissions contained herein shall not be
construed as permission to allow any conditions to exist in violation of the codes of the City of Wheat Ridge
Rough Framing and Wood Requirements
The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and
rough heat and ventilation are complete. The building should be fully enclosed with the roof covering and
siding in place.
2 Fire blocking shall be installed to cut off all concealed draft openings in the following locations: (IRC 302.11)
A. In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor
levels, and at 10 -feet horizontal intervals. B, At interconnections between concealed vertical and horizontal
spaces such as occur at soffits, drop ceilings, and cove ceilings. C. In openings around vents, pipes, ducts, cable,
wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. D. In
concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the
run of the stairs at unfinished walls.
18 There shall be a floor or landing on each side of each exterior door, except where a stairway with 2 or fewer
risers located on the exterior side of the door, other than the required exit door, a landing is not required for the
exterior side of the door. The landing must be no lower than 73/ -inches below the top of the threshold of the
door provided the door does not swing over the landing. (IRC R311)
19 Stairways must be at least 36 -inches in width. Handrails shall not project more than 4% -inches. The
maximum rise may not exceed 7% -inches. The minimum tread depth may not be less than 10 -inches. Minimum
headroom is 6 -feet, 8 -inches. For stairways with solid risers a nosing of %-inch to 1% -inches shall be provided.
When open risers are used the opening between the treads shall not allow the passage of a 4 -inch sphere to
pass through. Landings must be provided at the top and bottom of the stairway that is the width of the stairway
measuring at least 36 -inches in the direction of travel. Handrails shall be provided on at least one side of
stairways with 4 or more risers and ramps with a slope exceeding 1:12. Handrails shall be mounted 34 -inches to
38 -inches above the nosing of the treads. Handrails must be continuous for the entire length of the stairs and
provided with a minimum space of 1% -inch between the wall and the handrail. Ends shall be returned or
terminate in newel posts or safety terminals. See the requirements and more information. (IRC R311.7.8.2)
20 Handrail Grip Size Shall Be:A. Circular Handrails: 1% -inch to 2 -inches perimeter. B. Non -Circular: 4 -inches to
6% -inches perimeter with a maximum cross section of 2% -inches. C Perimeter Dimension Greater than 6% -
inches: shall have a finger recess on both sides.
21 Guards must be provided for porches, screened porches, balconies, fixed seating and raised flooja6faces
more than 30 -inches above the floor or grade below. Guards must have a minimum height of 36 -inches
sides of stairs with a total rise of more than 30 -inches above the floor or grade below shall have guarlA of le
0
than 36 -inches high. Intermediate rails shall not allow the passage of a 4 -inch sphere. (R312) Window fall
protection must be provided for window openings less than 24 inches above the finished floor and more than 72
inches above grade or surface below. (R312.2)
22 Safety glazing shall be installed in the following hazardous locations and be permanently labeled as safety or
tempered glazing: glazing panels in doors; glazing enclosing spas, bathtubs or showers; glazing panels adjacent
and within 24 -inches of the edge of a door; glazing panels greater than 9 square feet within 18 -inches of the
floor; glazing used for railings; glazing used for barriers for swimming pools and spas; and glazing enclosing
stairways, landings, and ramps within 36 -inches horizontally of a walking surface. See the Boulder County Land
(IRC R308)
Heating and Ventilation Requirements
32 Bathroom exhaust fans shall exhaust directly to the exterior and must be provided in bathrooms where
windows of at least 3 square feet are not provided. The mechanical ventilation must be capable of providing an
exhaust capacity of 50 cfm intermittent or 20 cfm continuous exhaust. (IRC R303.3, M1507.4)
33 Appliances and equipment shall be installed in accordance with the conditions of their listing.
Manufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1,
M1401.1,(M1902.2)
34 Appliances shall be accessible for inspection, service, repair and replacement without removing permanent
construction. 30 -inches of working depth and width shall be provided in front of the control side of an
appliance. (IRC M1305.1)
35 Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407)
Electrical Requirements
36 All hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical
connection at the time of rough inspection.
37 Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at least
3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through
the fixture into the ceiling cavity. (IRC N1102.4.5)
47 Tamper -resistant Receptacle outlets are required in every kitchen, family room, dining room, living room,
parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along
the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14)
48 Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the
counter top and spaced so no point exceeds 24 -inches from an outlet. B. Island and peninsula counters with a
length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet. C. At
least one receptacle shall be installed in a bathroom within 36 -inches of each basin.
49 At least one receptacle outlet must be installed in each laundry, basement, attached garage and detached
garage with power. F. At least one receptacle outlet that is accessible while standing at grade level and located
not more than6-feet, 6 -inches (1981 -mm) above grade, shall be installed outdoors at the front and back of each
dwelling unit having direct access to grade. Balconies, decks, and porches that are accessible from inside of the
dwelling unit and that have a usable area of 20 square feet. F. Attics or crawlspaces containing equipment must
be provided with at least one receptacle outlet within25-feet of the equipment. G. Hallways 10 -feet or more in
length.
50 Two 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining
area. At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch
circuit shall supply laundry. (IRC E3703.2, E3703.3, E3901)
51 Ground fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the
following locations: bathrooms, garages, unfinished grade level accessory buildings, at exterior locations,
crawlspaces, unfinished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks,
boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location.
(IRCE3902, E3902.11)
50 Combination type Arc -Fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch
circuit outlets in Receptacle outlets are required in every family room, dining room, living room, parlor, library,
den, sunroom, bedroom, recreation room, hallway, closets, and similar dwelling areas. (IRC 3902.12)
51 At least one wall switch -controlled lighting outlet shall be installed in every habitable room, bathroom,
hallway, (10ft) stairway, attached garage, detached garage with electric power, and at the exterior side of each
outdoor egress door having grade level access. Attics, under floor spaces, utility rooms and basements
containing equipment or used for storage must be provided with a switch
52 Smoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring operated
light. (IRC E3903)with battery backup and shall be interconnected so the actuation of one alarm will activate all
alarms in the dwelling unit. Smoke alarms shall be installed in the following locations: (IRC R314) A. In each
sleeping room; B Outside each sleeping area in the immediate vicinity of the bedrooms; and C. One on each
additional story including basements.
53 Carbon Monoxide alarms are required in a single-family dwelling that has fuel -fired appliance(s), or a
fireplace, or an attached garage. The alarm must be installed within 15 -feet of the entrance to each sleeping
room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and
has a battery backup. They may be combined with a smoke -detecting device if the combined device complies
with applicable law. (IRC R315)
54 Clothes closet lighting shall be limited to surface -mounted or recessed incandescent fixtures with completely
enclosed lamps, and surface -mounted or recessed fluorescent fixtures.Surface mounted fixtures shall be
installed on the wall above the door or on the ceiling with the following clearances between the fixture and the
nearest point of a storage space: (IRC E4003.12)A. Incandescent fixtures or LED shall have a minimum 12R&Rf
clearance. B. Fluorescent fixtures shall have minimum 6 -inch clearance. Recessed fixtures shall be insth ftPhidge
the wall or ceiling with the following clearances: A. Recessed incandescent fixtures shall have a minimum i6-
inch clearance to the nearest point of storage. B. Recessed fluorescent fixtures shall have a minimum g`-'(i� y Division
clearance to the nearest point of storage.
55 Working space must be provided around energized equipment for servicing and maintenance. The minimum
dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the equipment. Working
space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2)
56 Electrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or
accumulate n wiring compartments or other electrical parts. Fixtures installed in wet locations must be labeled
"suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations"
or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be
enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use
cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located
within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8,
E4002.9,(E4002.10, E4003.9, E4003.10,E4003.11)
Plumbing Requirements
58 DWV systems shall be tested on compellation of the rough piping installation by water or for piping system
other than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its
entirety or in sections after rough piping has been installed .1) Water test 10 feet above the highest fitting
connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes.
2) Air test shall maintain 51hs of pressure for 15 minutes.
59 Piping must be inspected and tested prior to concealing. It shall be protected against physical damage and it
must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1)
60 Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be
finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must
have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches.
Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb
threshold not less than 1 -inch below the sides and back of the receptor. The curb shall measure a minimum of
2 -inches to a maximum of 9 -inches above the top of the drain. (IRC R307, P2708, P2709)
61 The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets,
and lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch
clearance to wall or to a toilet. (IRC P2705)
62 Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic
mixing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or
CSA6125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device
that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 120'. (IRC
P2708.3,P2713.3)
63 Shower doors shall have safety glazing; hinged show door shall open outward. (R308.4.5, P2708.1)
64 Backflow prevention must be provided to prevent contamination of potable water. This includes but is not
limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers.
Backflow device must be inspected and approved by a 3rd party agency. (IRCP2902.2, Table P2902.3, P2717)
Insulation
65 R-20 Walls
R-49 Ceiling
R-19 Crawlspace Window
U -Factor .32 Floor R-30
66 Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum
R-6. ( N1103.2.1)
67 Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing
devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must
terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building
envelope. (G2426.4)
Class I or II vapor retarders are required on the interior side of the insulation in framed walls, floors and
roof/ceilings of the building's thermal envelope. The vapor barrier is not required in construction where
moisture or freezing will not damage the materials, or where the framed cavity (or space) is ventilated to allow
moisture to escape. A vapor retarder is not recommended on a concrete basement foundation wall or in a
shower /bath compartment (IRC 702.7, R702.7.1).
Wallboard Requirements
68 The garage shall be separated from the residence and its attic by materials of not less than %-inch gypsum
board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms
above by not less than 5 8 -inch Type X gypsum board. Where the separation is a floor -ceiling assembly, the
structure supporting the separation shall also be protected by not less than %-inch gypsum board. (IRC R302.6)
Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in
thickness, solid or honeycomb core steel doors not less than 1 -inch thick, or 20 -minute fire -rated doors.
Openings are prohibited between garages and rooms used for sleeping. (R302.5.1 )Doors between attached
garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be
self-closing and self -latching.
70 Nail spacing for gypsum board !/ gypum board Ceiling 16oc, 7", nails 12", Type S screws %2 wall spacing
24"OC, 8" nail spacing. 12"OCscrews. 5/8 ceiling board 16"OC, 7"nails I2"spacing, screws 240C 8".
72 Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic tile or
other required nonabsorbent finish material shall conform to ASTM C1396, C1178 or C1278. It is permitted on
ceilings where framing spacing does not exceed 12 -inches o.c. for %-inch thick or 16 -inches o.c. for 5 8 -inch
thick gypsum board. Water-resistant gypsum board shall not be installed over a vapor retarder in a shower or
tub compartment and may not be used where there will be direct exposure to water, or in areas of contine,9,4�
high humidity. All cut and exposed edges shall be sealed. (IRC R702.3.8)
Wheat Ridge
Building Division
.. City of id
Wh&at CIe
OMMUNITY DEVELOPMENT
SUB -CONTRACTOR AUTHORIZATION FORM
This form must be signed by each sub -contractor.
This form will not be accepted with missing information.
Subcontractor's City of Wheat Ridge License number must be provided in the applicable space.
Subcontractor's insurance and license must be up to date prior to permit issuance.
G c
Project Address: � i�,? � Cl c j�, �� '�,'V(',� P Permit #:
General Contractor: Ct r �{ :An lC b�Vx .LG..
I Electrical Sub -Contractor I
Company Name: 4 j f -:A! c_C Phone #: _% 2,0
State License #: 10/0/(o Master #: C)G Do YZ
Wheat Ridge License #: % o l, 3 ``r (required field)
Signature of Authorized Agent Date
Plumbing Sub -Contractor
Company Name: f ,G�� ,[ r UJQ Phone #: 74?y u •fig Wiz/
State License #: —Master #•
Wheat Ridge License #: (required Geld)
Signature of Authorized Agent Date
Mechanical Contractor
Company Name:
Phone:
Wheat Ridge License #: (required Geld)
Signature of Authorized Agent Date
Main Floor, ground level
Kitchen
Replace leaky hose valve outside of house
19'
Old washer dryer Ic cation
13'
-Refinish hard wood floors throughout main floor
-New Kitchen Cabinets
-Remove old carpet.
-Demo kitchen tile floor, replace with hardwood
-Replace windows to match existing sizes.
-Replace existing can lights with led lights, no local
-Cap plumbing at old washer location
* f4" <A4& kZr in OLA Lt //c3 ` cl c ut
�`"` `' v' ` Living Room
Cis n; ckde
on change
Rear of House (West)
0
Bath #2
Bath #1 -Re-tile floor,
-Replace vani
• L
lose®r4x,'Cl
et
3cr-
a
48'
Front of House (East)
Clos
Demo tile wall ' Enclose wall
Closet
Bedroom #3
12.5'
4765 Saulsbury St.
Closet
9.5' Bedroom #2
10'
>q w )e )ICA II
26'
Cr,>M P )y
�-Pc
Aj rr--- C
City of
W heat Rid9®
11uiidin
S Division
S
Basement 4765 Saulsbury St.
Rear of hni jse IIA/Pctl Egress window
M
Front of house (East)
II
is'
City of
Wheat Ridge
Building Division
- . City of Wheat Ridge
E -Res. Electrical Service Upgr PERMIT - 201802138
PERMIT NO: 201802138 ISSUED: 07/31/2018
JOB ADDRESS: 4765 Saulsbury St EXPIRES: 07/31/2019 -
JOB DESCRIPTION: Electrical total replacement of current 200 amp service with a new 200 amp
service and installation of a new lever electrical meter installed.
*** CONTACTS ***
OWNER (303)422-3085 REEVES PATRICIA A
SUB (720)998-2250 Ryan Underwood 180234 Mastiff Electrical Solutions
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,500.00
FEES
Total Valuation 0.00
Use Tax 94.50
Permit Fee 125.05
** TOTAL ** 219.55
*** COMMENTS ***
*** CONDITIONS ***
Both the front and back of this permit are required to be posted on the job site at all
times. If the complete permit is not present, inspections WILL NOT be performed.
Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required
to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every
level of the structure.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications;
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this ermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying )Tans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and maybe subject to a fee equal to one-half of the original ermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable codec or any ordinanki or regulation of this jurisdiction. Approval of work is subject to f any
inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
1 ; r City of
COMMUNITY DEV18LOPMENT:
Building & Inspection Services Division
7500 W. 2911 Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 " Fax; 303-237-8929
Inspection Line: 303-234-5933
Email: permitsAci.wheatridoe.co.us
Building Permit A
(please prino:
FOR OFFICE USE ONLY
Plan/Permit #
Plan Review Fee:
lication
Ob`S
� 11(if different than property address)
Address SAYVA i
City, State, Zip:
Mllf
�i f: ; W-
�T.
L t 1
AMC
101
Electrical: Plumbing: Mechanical:
W.R. City License # W.R. City License # W.R. City License #
mc. o('-'C)06aq
Other City Licensed Sub: Other City Licensed Sub:
City License # City License #
14� o b).q?31-11
❑ COMMERCIAL RESIDENTIAL
Wako.\ �r�i Ce_
r� Occupancy Type: Construction Type:
Sq. FULF �) BTUs
Amps Squares _
Gallons
�'j (Contract value or the cost of all materials and labor included in the enure project)
$ -) 00
OWNERICONTRACTOR SIGNATURF. OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Vdheat Ridge or covenants, casements or restrictions of record; that all measurements shonm and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the
truthfulness of the information providei the application. -------.
HAPINN:
W. %:
Building Division Valuation:
q7&Coo'4
INSPECTION RE OARDtf
INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection
INSPECTION REQUEST LINE: (303) 234-5933
A
Occupancy/Type
Inspections will not be performed unless this card is posted on the project site.
**Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date
Inspector
Initials
Comments
Pier
Plumbing
Concrete Encased Ground (CEG)
Mid -Roof
?j • I
Foundation / P.E. Letter
�,�%
Lath /Wall Tie
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground/Slab Inspections Date Inspector
Initials
Comments
Electrical
Comments
Sewer Service
Plumbing
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections
Rough Inspections
Date
Inspector
Initials
Comments
Wall Sheathing
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
Mid -Roof
?j • I
�,�%
Lath /Wall Tie
Fire Inspection / Fire Protection Dist.
Rough Electric
Final Electrical
Rough Plumbing/Gas Line
Final Plumbing
Rough Mechanical
Final Mechanical
Rough Framing
Roof
Rough Grading
Final Window/Doors
Insulation
Final Building
Drywall Screw/ Nail
NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
Final Inspections
Date
Inspector
Initials
Comments
Landscaping & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW & Drainage / Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
Final Plumbing
Final Mechanical
Roof
Final Window/Doors
Final Building
NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
"For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
i CITY OF WHEAL RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: W &L"
Job Address:41 !-. > ,,�� SI -
Permit Number: 2_00 i�414Cs
LAT"15 W
7
❑ No one available for inspection: Time
Re -Inspection required: Yes No
When corrections have been made, call fore -inspection at 303-234-5933
01"t-,
Date: 1-7—inspector: jalon C.
DO NOT REMOVE THIS NOTICE
CITY OF WHEAT 1BIDGE
}-841fding Inspecti0i Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: � � � r—u
Job Address:��' L41., U�
Permit Number: 01-1 ��`1 LP
❑ No one available for inspection: Time �. �� ANI�.Y
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
Date: Inspector: "
DO NOT REMOVE THIS NOTICE
, City of Wheat Ridge
Residential Roofing PERMIT - 201704146
PERMIT NO:
201704146
ISSUED:
07/15/2017
JOB ADDRESS:
4765 Saulsbury ST
EXPIRES:
07/15/2018
JOB DESCRIPTION:
Residential Re -roof
to install
GAF Timberline HD
asphalt shingles with 25
sq.
*** CONTACTS ***
OWNER (303)422-3085
REEVES PATRICIA A
SUB (303)797-8600
Kevin Trizna
170246 M4 Roofing
& Gutters
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
2405 / BARTHS, COULEHAN GRANGE,
WHEAT BLOCK/LOT*:
0 /
*** FEE SUMMARY ***
ESTIMATED PROJECT VALUATION:
9,948.01
FEES
Total Valuation
0.00;
Use Tax
208.91
Permit Fee
204.30
- — �-
** TOTAL **
413.21
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
installation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City of Wheat Ridge
Residential Roofing PERMIT - 201704146
201704146 ISSUED: 07/15/2017
4765 Saulsbury ST EXPIRES: 07/15/2018
Residential Re—roof to install GAF Timberline HD asphalt shingles with 25
sq.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be pe ed is disclosed in this document and/or its' accompanying approved plans and specifications.
--- - '7 [ C- _L l
Signature of OWNER or CONTRACTOR Circle one) Date I
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all re uired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting a rmit shall onst d o be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordi
It
o i s fiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dane Lovett
From: no- reply@ci.wheatri dge.co.us
Sent: Thursday, July 6, 2017 1:19 PM
To: Permits CommDev
Subject: Online Form Submittal: Residential Roofing Permit Application
Residential Roofing Permit Application
This application is exclusive) for new permits for residential roofs and for licensed
pP Y p
O
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
-
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
`v
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number
Property Owner Email
Address
4765 Saulsbury St
Patricia Reeves
303-422-3085
Field not completed.
t q�-�.�2�
Do you have a signed Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
Contractor's License
Number (for the City of
Wheat Ridge)
Contractor Phone
Number
M4 Roofing & Gutters
170246
3037978600
Contractor Email Address laura@m4roofing.com
Retype Contractor Email laura@m4roofing.com
Address
DESCRIPTION OF WORK
Are you re -decking the No VZ
roof?
Description of Roofing GAF Timberline HD
Material
Select Type of Material: Asphalt
If "Other" is selected Field not completed.
above, describe here:
How many squares of the 25
material selected above?
Does any portion of the No
property include a flat
roof?
If yes, how many squares Field not completed.
on the flat roof?
TOTAL SQUARES of all 25 v/
roofing material for this
project
Provide additional detail Tear off and reroof - 4/12
here on the description of
2
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
9948.01
Project Value (contract
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Rhonda Bedwell
Email not displaying correctly? View it in your browser.
3
.R.1,14 Contracting, LLC
4719 S. Santa Fe Cir. Unit 2
Englewood, CO 80110
Phone: 303-797-8600
Fax: 303-797-8601
Owner VI]A'+ra - 5 Date
Address 1tf Email
City, State Zip
J4&= Home Phone
Job Location Cell Phone -�o I Z- *_50
ear Off 1 /�n 3Aers of existing shingles U Wood shake tear off
ETIr 11 1 W f Synthetic underlayment
Psta 6a,44t-
e— AF
W>stall Cer;tai rd�amko alarkey I Owens Coming
13'Shingle:
IL
hingle Color:
stall decking (7/16" OSB) 154ck tke--(.b J
Jlnstall Ice and Water shield
13 Install new step flashing: Col br: Black / Grey /81r40 Mill
ffinstaill new drip edge on rakes Color: '-w--rr White / Other:
nn Install new drip edge on eaves Color:'\Brown YWhite/Other:
Install new roof vents
Paint roof vents and stacks to blend with g e calor
Nail & seal new pipe flashing and van
Clean up & remove debris
Magnetize yard for nails
Clean gutters
Provide local building permit
Manufacturer's warranty based on which shingle is installed
ET Provide a 60 -month installatio warranty. (Not valid until account is paid in full)
Approximate Dates of 1 71"', 4— 1
R
Gutters:
Gutter size: 5- 06- 0 Replace AI(3OthE
Total Gutter Length: ' LF
Total Downspout Length: LF
Downspouts: [32"x3'-C13"x4"[3Replace AI(30thf
ti
Color.
Instructions:
SYSTEMS PLUS / GOLDEN PLEDGE
See addendum
approximate costs of the services based on damages known at the time this contract is entered is $
Contracting, LLC, however, will perform the scope of work approved by the insurance company for the amount'dT the insuranc
roved proceeds, with no additional cost to you except for your. deductible. The final scope and price agreed on between th
iranee company and M4 Contracting, LLC shall become the final contract price for the insurance approved scope. You will b
)onsible to pay for any upgrades or additional work authorized by you that the insurance company determines is not covered withi
scope of coverage provided by your insurance policy. Supplemental claims billed by M4 Contracting, LLC that are approved by th
iranee company for additional work or increases in cost become a part of this contract.
'hen the insurance company and M4 Contracting, LLC agree upon a price, that amount will be the final contract amount and
)ntracting, LLC will install the roof. M4 Contracting, LLC will receive all insurance proceeds for the work completed by M4 Contracting,
the insurance company does not approve the roof replacement, en m this contract is null and void. M4 Contracting, LLC shall hold in t
iy payment from the property owner until the roofing e have
been delivered to the jobsite or has performed a majority of
iofine work.
" I r - -7-
M4 C rntracting, LLC Representative Date
We may withdraw this proposal if not accepted w/m 10 days.
Acceptance of Proposal - M4 Contracting, LLC is authorized to do the work as specified in the TERMS above,
Owner/Authorized Agent Date
I have read and understand the terms and conditions listed on the back side of this page. Homeowner Initials:
♦
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office,' (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type PF-C ffo ZF',E:
Job Address M_ < 7
Permit Number !lr
t
❑ No one available for inspection: Time AM /PM
Re- Inspection required: Yes
When corrections have been made, call for re- inspection at 303 - 2345933
Date: ?IJr Inspector f C
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
/ Residential Mechanic PERMIT - 110214
PERMIT NO: 110214
JOB ADDRESS: 4765 SAULSBURY ST
DESCRIPTION: Replace 135,000 btu boiler
ISSUED: 03/07/2011
EXPIRES: 03/06/2012
* ** CONTACTS * **
owner 303/422 -3085 Patricia Reeves
sub 303/422 -6073 Leon Gonzales
06 -0027 Best for Less Heating &Cooling
** PARCEL INFO
**
ZONE CODE:
UA
USE:
UA
SUBDIVISION:
0801
- BLOCK /LOT##:
0/
** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 4,500.00
FEES
Permit Fee 40.00
Total Valuation .00
Use Tax 81.00
** TOTAL ** 121.00
Conditions:
Work shall comply with 2006 IRC & 2005 NEC. Per IRC Sec. R313, smoke detectors
are required to be installed in every sleeping room, in hallways outside of
sleeping rooms, and on every level of the structure. Carbon Monoxide detectors
are required to be installed within fifteen(15) feet outside the entrance to
each sleeping room. Subject to field inspections.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and
specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the
legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform
the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all
entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in
this document and /or its'Laccompanying approved plans and specifications.
Signature of OWNR ACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and
specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances,
regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must
be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted
at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to
the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired
permits is at the sole discretion of the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior
and specific approval.
S. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy
of all required inspections and shall not proceed or conceal work without written approval of such work from the
Building and Inspection Services Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of
any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject
to field inspec ion.
Signature f Building Offical - Date
INSPE ION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855
REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Cit of
W h eat
heat �Ce Date:
CONLMUNriY DEVELOPMENT
Plan #
Building & Inspection Services Division
7500 W. 29 Ave., Wheat Ridge, CO 80033 Permit # j21
Office: 303 - 235 -2855 * Fax: 303 - 237 -8929
Inspection Line: 303- 234 -5933
Building Permit Application
Property Owner (please print): ��I RtC tali, Phone: > <122^ 305
Mailing Address: (if different than property address)
Address:
City, State, Zip:,
t
0071taCtQ11:
Contractors City License #: Phone:
ul�ontracto7s� "; ";
Electrical: Plumbing: Mechanical
City License # City License # City License #
Dessrtpttort of �uorka
wsrW (t`;c tAr r✓xtsT >t xt
s3otl��tL.. I' (gyp Contract Value:
5t7
$ 6 to , n
Review Fee (due at time of submittal):
Squares BTU's Gallons Amps Sq Ft. $
OWNER /CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on
this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work
and am also authorized by the legal owner of any entity included on this application to list that entity on this application.
CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)
PRINT NAME: 022 t�0WZP)4 % SIGNATO DATE; QLI___
701JJNGCOMMEN�TS ,/ v - ✓i" <.r��r ✓r�r�P /''i r ,.N � � � �"r i- �F`.�,r�`asl'r<,. ^�"yw.arr.�sr""`,3 fret ° � r ���
,+ t � .Y. z. " ,'.� rr' ? e ,+ �' "`. Y e A7✓ 2CY <„ �r` ?`r'`r G ?a ,fi ,� y r r� � ,.� > c am; ,
. .�'' j ZOringa � /J-f . ��`+"rsNry'r y S�tr .;s _; �alr�c ��� �s'u xr r G � r /.*�i�irr'G.%
s3;�RCYIOWeieh�rso �ti r"3jr rs3.u`lr��rr. cyr�r w�; vr���I�� � ✓�u^icvsi ✓cam >>r�h�fid�r�Ora ��r
i''t 1. r^ �r,. �`��c -c .i . l+"y ,fir /i vl"�✓"'- :i r.�, f r i" ,S �ti.'� ✓ � X3"2 r' � ✓'�' l✓ t// is �� +'� .
f I3YIILDf NGDE �R (�1 r a ��/ r r h- �f?r�r ��rt r� K r �, rri rrtrtaJy� £'r : J ✓
✓✓' RevleyveJ' � ✓ y ✓"Yi ra� rP Fr � r Gr r r r�rr� j `�, ca/ ✓a � ^fs y� ✓r� � J � y rr rr � fi r. i,
l 3 w: r /`�'`r/,U�rAS ..%. xG� i � F r � t �r..rr -✓ r�� �" tix .t � /' i .-!> i'i",� r'' %`?, C , r /' I y. s ' � r � ham, r N .,
'/ ;! �`^rr'rr. ^r. r!'rlY ./' / ✓ ir � �r� t� ��3'� �Y s� �"��✓r�� ✓rF c :513 rM rS�� ,r �' �
� � �� /„ � �rl] f�5 kr*i i 4Fj /r Y� 1( r r �7 > w e 7 "a + K /r �� ✓'�y7� J i %r,
�S -'. w„1r?t Ii �r/y -; sr %�? Fr�rT ✓rf�r':! 's � r'3 rr a?� l r� r'?yG��,- t�ti'Gl'o��1��� 3�„r.+�o- "�""1..��'�2r `'�v�� r ri >'' r
PUBLIC WORjCS COM ENTS �b a'c' ✓ G e"r �C"r ✓ 't - "��,+>> 8 � �.r'x . r � �.
! '7t -1 tr r a r; a ✓, .✓� ,r l�r: y OCCUP ✓ AflGY
> /'� � a r°rr., rFr >a /%r.., a1 a .-' r r / ✓ r-C rr.." r..r`a < s l.rr
f ReV18W�[' rr rr� f r�r � � r � 4 y �f /� 3 > g ✓zv;'%r / r �r �j ✓ /ra ✓� � ✓ r r > i
t-7RE DEPARTMENT r r r rr�, ac s � a r ✓ l �
r o ;-r �, .p approvgd,.w/ cornment�s ❑ disapproved r �t7 �y rey��ew'regUr recd Bidg Valuation. $