Loading...
HomeMy WebLinkAbout4300 Ingalls StreetINSPECTION RECORD Occupancy/Tye INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site. "Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Initials Comments Pier Wall Sheathing Mid-Roofrip Lath / Wall Tie Concrete Encased Ground (CEG) `° Foundation / P.E. Letter Rough Electric* Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid-Roofrip Lath / Wall Tie `° 166 Rough Electric* Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date _ Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather ., City of Wheat Ridge V, Residential Roofing PERMIT - 2€11704893 PERMIT NO: 201704893 ISSUED: 07/26/2017 JOB ADDRESS: 4300 Ingalls ST EXPIRES: 07/26/2018 JOb DESCRIPTION: Residential Re -roof to install 0/C TRU-DEFINITION DURATION STORM IR4 asphalt shingles with 37sa (17 sq pitch & 20 sq flat) REMOVE ASPHALT SHINGLES AND INSTALL ASPHALT shingles, pitch3/12 and remove some flat areas and replace with polyglass *** CONTACTS *** OWNER (720)304-7484 LATSIS GEORGE SUB (303)274-1111 Manuel Rocha 021129 Horn Brothers Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,509.00 FEES Total Valuation 0.00 Use Tax 199.69 Permit Fee 204.30 ** TOTAL ** 403.99 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Mechanic PERMIT - 201705197 PERMIT NO: 201705197 ISSUED: 08/02/2017 JOB ADDRESS: 4300 Ingalls ST EXPIRES: 08/02/2018 JOB DESCRIPTION: Permit to replace Furnace in same location, replacing ducting, 80% AFUE, 70K BTU, vented to existing "B" vent. Connect to existing gas. * * * CONTACTS OWNER (720)304-7484 LATSIS GEORGE SUB (303)421-4020 Allen Campbell 021467 Allen's Heating, A/C & S.M., I *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,100.00 FEES Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 86.10 ** TOTAL ** 126.10 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable bung codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that Ian le ally authorized to In all entities named within this docwnent as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing, and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of anew permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offcial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field ---V— • e Signature of Chief Building Oficial fate REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS L C' I N S P E C ION RECORD INSPE&JON ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Occupancy/Type Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Initials Comments Pier Sewer Service Concrete Encased Ground (CEG) Foundation / P.E. Letter Lath / Wall Tie Do Not Pour Concrete Prior To Approval Ur i ne ADove inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing r)e% Mt%f r..nvor IlndPrnrnund or Relow/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections _ Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric' Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing f` Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and eiectricai fdw vdnage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather ' City of Wheat Ridge Residential Mechanic PERMIT - 201705197 PERMIT NO: 201705197 ISSUED: 08/02/2017 JOB ADDRESS: 4300 Ingalls ST EXPIRES: 08/02/2018 JOB DESCRIPTION: Permit to replace Furnace in same location, replacing ducting, 80% AFUE, 70K BTU, vented to existing "B" vent. Connect to existing gas. *** CONTACTS *** OWNER (720)304-7484 LATSIS GEORGE SUB (303)421-4020 Allen Campbell 021467 Allen's Heating, A/C & S.M., I *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,100.00 FEES Furnace Replacement 40.00 Total Valuation 0.00 Use Tax 86.10 ** TOTAL ** 126.10 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be erformed is..disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTQW (Circle one) Byte I. This permit was issued base on a in ormation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall construed to be a permit for or an approval of, any violation of any provision of any applicable code or any ordinance or regulatio is jitrisdiete�Appr val work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat j"jge- COMMUNiTy DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a_)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: .1 � A Plan/Permit # 9`7 Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): IJ%/� C/- 2 Phone: „. 0­3722-ZH7 Property Owner Email: Mailing Address: (if different than property address) Address City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: �1 �%•�6.�.. �. C> �4 f, �•i Z�,C Contractors City License #: 1 L -i l Phone: 203 YV 1 i Contractor E-mail Address: G �/��'-`fAfAl%F�s= 6 Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Gar shed, deck, etc.) 3 MECHANICAL SYSTEM/APPLIANCE REPAIR or EP ME ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. Ft./LF Amps Btu's 70j AX) U Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): L C / DATE: / ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ A r City of Wheat Ridge Residential Roofing PERMIT - 201704893 PERMIT NO: 201704893 ISSUED: 07/26/2017 JOB ADDRESS: 4300 Ingalls ST EXPIRES: 07/26/2018 JOB DESCRIPTION: Residential Re -roof to install 0/C TRU-DEFINITION DURATION STORM IR4 asphalt shingles with 37sq (17 sq pitch & 20 sq flat) REMOVE ASPHALT SHINGLES AND INSTALL ASPHALT shingles, pitch3/12 and remove some flat areas and replace with polyglass *** CONTACTS *** OWNER (720)304-7484 LATSIS GEORGE SUB (303)274-1111 Manuel Rocha 021129 Horn Brothers Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,509.00 FEES Total Valuation 0.00" Use Tax 199.69 ` Permit Fee 204.30 �e__------ - ** TOTAL ** 403.99_--- *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. � A City of Wheat Ridge Residential Roofing PERMIT - 201704893 PERMIT NO: 201704893 ISSUED: 07/26/2017 JOB ADDRESS: 4300 Ingalls ST EXPIRES: 07/26/2018 JOB DESCRIPTION: Residential Re -roof to install 0/C TRU-DEFINITION DURATION STORM IR4 asphalt shingles with 37sq (17 sq pitch & 20 sq flat) REMOVE ASPHALT SHINGLES AND INSTALL ASPHALT shingles, pitch3/12 and remove some flat areas and replace with polyglass I, by my signature, do her attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po Flans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermitfee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Ch" eTBuilding Official `b Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz G g From: no-reply@c i.wheatridge.co.us Sent: Tuesday, July 18, 2017 2AS PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application -� Categories: Gina Residential Roofing Permit Application CQ �J This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Duplex are on the property? PROPERTY INFORMATION Property Address 4300-4302 Ingalls St Property Owner Name George Latsis Property Owner Phone 303-304-7484 Number Property Owner Email humberto@hornbrothersroofing.com `qq Address $ qos Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Horn Brothers Roofing Contractor's License Denver Number (for the City of Wheat Ridge) Contractor Phone 7203912444 Number Contractor Email Address humberto@hornbrothersroofing.com Retype Contractor Email humberto@hornbrothersroofing.com Address DESCRIPTION OF WORK Are you re -decking the No roof? Description of Roofing OC TruDefinition Duration Storm IR4 Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 17 material selected above? Does any portion of the Yes property include a flat roof? If yes, how many squares 20 on the flat roof? TOTAL SQUARES of all 37 roofing material for this proj ect Provide additional detail Remove asphalt shingles and install asphalt shingles pitch 3:12 here on the description of and remove some flat areas and replace with Polyglass z work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Humberto Cruz Email not displaying correctly? View it in your browser. 3 A COLORADO COMPANY In Business Since 1984 2325 S. JASON STREET DENVER, COLORADO 80223 303-274,1111 ROOFING AGREEMENT OWNER George & Jim Latsis STREET 4300-4302 Ingalls St. CITY, STATE, ZIP Wheat Ridge, CO 80033 PHONE: 303-304-7484 PHONE: 720-373-1997 EMAIL: glatsis@msn.com SPECIFICATIONS ® TEAR OFF one (1) LAYER (additional layers extra $) ® REPLACE WITH OC TruDefinition Duration STORM IR4 ® COLOR OF SHINGLE DD_l FOLZI0 -b ® MANUFACTURER'S LIMITED WARRANTY Lifetime YEAR(S) ® HORN BROTHERS WORKMANSHIP WARRANTY three (3) YEAR(S) ❑ VALLEY SOFFITS boxed ® RIDGE MATERIAL OC TYPE Pro -edge ® DRIP EDGE ® EAVES n GfEU K Zrc ® RAKES ® HW/SW FLASHINGS ® HEADWALL ® SIDEWALL ® REPLACE PIPE JACK BOOTS ®REPLACE LP VENTS ❑ PAINT ROOF STACKS COLOR match ® I & W ® EAVES ❑ VALLEY ® PENETRATIONS ❑CHIMNEY(S) L� SKYLIGHT(S) ® INSTALL ICE SHIELD OVER ENTIRE 3/12 SLOPED ROOF PER ���pppE EXTRA WORK ® CLEAN-UP & HAUL OFF ROOFING TRASH ® CLEAN OUT GUTTERS ® ROLL MAGNET AROUND HOUSE PERIMETER ® REPLACE FURNACE VENT RAIN CAP AND STORM COLLAR ri SPECIAL INSTRUCTIONS 1. Shed roof NOT included rPaL`{ Q_A5S — W H ("ice 2. Includes all flat roof components per insurance 3. Install polvglass modified bitumen low -slope roofing where needed DATE 71612017 EXISTING SPECIAL ATTENTION AREAS ❑ COVER POOUDECK ® PROTECT LANDSCAPE ® GUTTERS (ANY OLD DAMAGE) replace per insurance PITCH: ANY AREAS UNDER 4/12 ® YES ❑ NO FLAT AREAS: ®YES ❑ NO LEAKS: WHERE INTERIOR DAMAGE: WHERE DOES DRIVEWAY HAVE CRACKS ❑ YES ❑ NO rvviw EXISTING TYPE ROOF asphalt AGE 5+ PITCH 3:12 ACCESS 1.15 STEEP 0.00 2 -STORY 0.00 Price includes 5" steel gutters & 2x3 downspouts per insurance scope of work. Gutters color:n Downspouts color: Ty) Replace roofing per insurance on house - $15,045.35 Replace guttering per insurance - $989.96 (175' gutter and 22' downspout) Approximate date of installation: JG PT. $ ,, 2 -0 17 Deposit amount received: Payment type: L /�6LJG TERMS WE HEREBY PROPOSE to furnish labor and materials in accordance with the specifications, set out herein, for the sum of $ $16.035.31 "Contract Price." When Tully executed by (:ompany and Uwner, this Kooting Agreement becomes a binding contract subject to the scope of worK specmed all applicable end t e terms oncthsupplements) ttth Buyers Rights and Homeowner Protection Agreement. This Agreement does not include any hidden structural issues uncovered during the tear -off of your roof, such as bad/rotted decking_ fascia. trusses skin sheathing issues or additional lavers of shingles BILLING AGREEMENT: 10% deposit; 40% upon materials arrival; remainder upon completion ACCEPTED BY,.," DATE 71612017 ACCEPTED BY DATE 71612017 ,9�6rge & Jii is -TF/27/7 Insurance Cam I Foremost Insurance SALESMAN Marty Rangel —Pd Claim # 009001 5002914011-1-1 martyrangeliMgmail.com Phone # & Fax #: 800-5- cell: 720-352-5008: office: 303-274-1111 A i CITYOF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE ❑ No one available for inspectio me / J AM/PM Re -Inspection required: Yes f No, When corrections have been made, call for re -ins 'ectin at 303-234-5933 Date: `C.% l Inspector: DO NOT REMOV 5 THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: __./ Job Address: —2)00 4 Permit Number: . 9-01-704695'r ❑ No one available for inspection: Time l AM/PM Re -Inspection required: Yes N When correcti.0fis h ve been made, call for re -inspection at 303-234-5933 Date: Inspector: �Q'NQ T REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _��9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M F _ Job Address: �/ 300. �T- A/,1fiL (_ f ❑ No one available for inspection_ Time AM/PM Re -Inspection required: Yes When corrections have been made, call for re-inspectibhfit,303-234-5933 611 Date: Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE '�� .A Building Inspection Division (303) 234-5933 Inspection line 1003) 235-2855 Office - (303) 237-8929 j Inspection Type 4eQ 6Z 1n ' 06 Job Address Permit Number C40116411 &Z M _ No one available for inspection: Time - AM/PM Re-inspection required Yes No When corrections have been made, call for W-inspection at 303-234-5933 Date: F 3 Inspector: 7t i Z I- r Property Owner (please print) J Phonei Contractor: 4. 1 e- Contractor License #: 99 Phone: 303 - - 7 Sub Contractors: Electrical City License #: w9 67 Plumbing City License Mechanical City License #: Company: ( 6(ec4-tic— Company Company: :5pf,J(Ce CAVO,--yAt- I Plan Review (due at time of submittal): $ Sq, Ft./L.Ft added: - Squares - BTU's - Gallons -.- Amps 15 ZONING COMMENTS: Zoning Reviewer; PUBLIC WORKS COMMENTS: Reviewer: BUIL.D NG DEPARTMENT COMMENTS' Reviewer. FIRE DEPARTMENT': 0 1 approved wl comments 0 disapproved 0 no review required DEPARTMENT USE ONLY