HomeMy WebLinkAbout2919 Eaton StreetCity of Wheat Ridge Residential Solar PERMIT - 201800332 PERMIT NO: 201800332 ISSUED: 02/16/2018 JOB ADDRESS: 2919 Eaton ST EXPIRES: 02/16/2019 JOB DESCRIPTION: Install a 2.925 KW roof -mounted grid -tied solar PV system; install 13.5 KWH Tesla powerwall *** CONTACTS *** OWNER (301)452-6353 AMARASINGHAM SAHADHEVAN & BARB SUB (888)765-2489 Jared A Miller 110035 SolarCity Corporation *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11,178.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. 1, by m signature, do hereby attest that the workio be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermrt. I further attest that 1 am le all authorized to include all entities named within this document as partes to the work to be performed and that all work to be incl a hi o nt and/ a om an g ed lan specifi atio s. Signature of OWNER or CONTRACTOR Circle one Date g ) I, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original pennit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or rek#lation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official y — Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 2p1�(.�i3r2 L ri Dear City of Wheat Ridge, We would kindly like to cancel the following permit and if we qualify please receive a refund for: • Barbara Amarasingham 2919 Eaton St, Wheat Ridge, CO 80214 Permit #: 201800332 Reason for cancellation: Customer is not moving forward with project. If we qualify for a refund, please send check to: • Tesla, Inc. 470 E. 76th Ave Unit 3A Denver, Co. 80229 Thank you, Jeremy Burks I Inspection Coordinator I Operations 470 E. 76'h Ave.; Unit 3A I Denver. CO 80229 c 303.619.2021 (e �burksCcDtesla.com City of Wheat Ridge -' Residential Solar PERMIT - 201800332 PERMIT NO: 201800332 ISSUED: 02/16/2018 JOB ADDRESS: 2919 Eaton ST EXPIRES: 02/16/2019 JOB DESCRIPTION: Install a 2.925 KW roof -mounted grid -tied solar PV system; install 13.5 KWH Tesla powerwall *** CONTACTS *** OWNER (301)452-6353 AMARASINGHAM SAHADHEVAN & BARB SUB (888)765-2489 Jared A Miller 110035 SolarCity Corporation *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11,178.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I asn-1e ally authorized to include all entities named within this document as parties to the work to be pend and that all wor `be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signa 'e of WNER or CONTRACTOR (Circle one) Date 1. ;This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a nermit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinqqce or regulation of this jurisdiction. Approval of work is subject to field inspection. w Signature of Chief Building OfMial Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. FOR OFFICE USE ONLY City of Date: Wheat _ge / COMMUNITY DEVELOPMENT Plan/Permit# �O/ Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 2919 Eaton St, Wheat Ridge, CO 80214 Property Owner (please print): Barbara Amarasingham Phone: (301) 452-6353 Property Owner Email: bamara@juno.com Mailing Address: (if different than property address) Address: Same as above City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor: Solar City Contractors City License #: 110035 Contractor E-mail Address: tward@solarcity.com Sub Contractors: Electrical W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: 253-720-4461 Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT BELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT x OTHER (Describe) Solar PV (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Install a 2.925 kW roof -mounted grid -tied solar PV system o., x ,3 ,5 )I<�\ T-t--s,c- Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) o PRINT NA: Chris Luther NAME: Chris ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS r (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)Z SIGNATURE:DATE: 211 /2018 Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ CITY OF WHEAT RIDGE JURISDICTIONAL NOTES FOR SINGLE FAMILY DWELLING ROOF MOUNTED PHOTOVOLTAIC SYSTEM The project plans were reviewed for compliance with the following codes and standards: 2012 International Residential Code (IRC); 2012 International Building Code (IBC); 2014 National Electrical Code (NEC) 2012 International Fire Code (IFC) and the 2012 International Plumbing Code U (IPC) : " �11 a. "The roof access point requiring a ladder shall not be located over a window, door or located where _aw0 it conflicts with overhead obstructions such as tree limbs, wires or signs." IFC 605.11.3.1 !►�� b. "An OSHA approved ladder shall be provided and secured to the structure at the approved roof access point per note above with a OSHA approved device during all inspections" c. "Applications for a photovoltaic system proposing a partial or complete re -roof of the existing roof shall first obtain a separate building permit for such work from the Building Division by a licensed contractor and shall pass a final inspection prior to installation of the photovoltaic mounting and/or rail system. 04 d. "Direct -Current Photovoltaic Source and Direct -Current Output Circuits on or inside a building shall be contained in a metal raceway. The wiring methods shall comply with the additional installation requirements of NEC 690.31 (G)(1) through (4)" e. "Where a UFER cannot be verified or is not present one supplementary ground electrode shall be installed and embedded a minimum of 8 feet into the ground and fitted with a listed clamping device." f. "Existing roof and plumbing vents shall not be obstructed by array installation. Plumbing vents are required to be re-routed through attic space and terminate a minimum of 6 inches above the roof line." Plumbing vents shall terminate to the open air (2012 IPC, Sec. 904.3) Markings, Labels and Wiring Signs 2. The format of all markings, labels and wiring signs including letter and background colors, letter height and capitalization, etc. shall be in compliance with ANSI Z535.4-2011 section 7 and safety colors of ANSI 535.1 safety colors as follows: a. DANGER: safety white letters on a safety red background b. WARNING: safety white letters on a safety orange background. c. CAUTION: safety black letters on a safety yellow background. d. NOTICE: italicized safety white letters on a safety blue background. e. SAFETY INSTRUCTIONS or similar words: safety white letters on a safety green background. 3. "All placards shall be weather resistant permanently etched placards. Handwritten signs will not be acceptable" Version #71.0 - TBD November 13, 2017 RE: CERTIFICATION LETTER Project/Job # 8029178 Project Address: Amarasingham Residence -_} 0 LIQ 2919 Eaton St Wheat Ridge, CO 80214 �irass� #� A AHJ Wheat Ridge SC Office � Parker- Desi n Criteria: g # - Applicable Codes = 2012 IEBC/IBC 2012 IRC, ASCE 7-10, and 2012 NDS - Risk Category = II - Wind Speed = 135 mph, Exposure Category C, Partially/Fully Enclosed Method''®, { ,s•Fi eek:� - Ground/Roof Snow Load = 30 psf (Unreduced)1 - MP1: 2x.6 @ 24" OC, Roof DL = 6.5 psf, Roof LUSL = 30 psf 0NAL - MP4: 2x6 @ 24" OC, Roof DL = 6.5 psf, Roof LUSL = 30 psf Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22567 < 0.4g and Seismic Design Category (SDC) = B < D To Whom It May Concern, Ajobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Hussefn A. Kazan, P. E. Professional Engfneer T: 609.642.9016 emafl: hkazanc@tes[a.com T = 5 L F= Hussein kazan Digitally signed by Hussein kazan Date: 2017.11.13 13:20:50 -05'00' Tesla, Inc. Version #71.0 - TBD HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware Hardware - Landscape Modules' Standoff Specifications X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MP1 72" 24" 41" NA Staggered 59.9% MP4 72" 24" 41" NA Staggered 59.9% Portrait Hardware Hardware - Portrait Modules' Standoff S ecifications X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MP1 48" 19" 62" NA Staggered 60.4% MP4 48" 19" 62" NA Staggered 60.4% Structure Mo nting Plane Frarning Type Spacing Pitch Qualification Results Member Eva!uation Results MP1 Stick Frame 24" O.C. 22° Member Analysis OK MP4 Stick Frame 24" O.C. 22° Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site. The existing gravity and lateral load carrying members were evaluated in accordance with the IEBC and the IBC. Tesla, Inc. T = 5 L n 3055 Ciearnew Way San Mateo CA 94402 p 050 638 1028 f 650 638 1029 STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1 Notes 1. ps = Cs'pf; Cs -roof; Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (C) (IS) p9; Ce 0.9, Ct=1.1, IS=1.0 Member Analysis Results Summary Governing Analysis Max Moment @Location Capacity DCR Result (+) Bending Stress (psi) 1,594.7 1 5.3 ft 1,547.3 103% Pass Member Properties Summary MP1 5/12 Horizontal Member Spans Overhang 0.32 ft Rafter Properties Actual W 1.50" Roof System Properties Span 1 10.07 ft Actual D 5.50" Number of Spans (w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A (in^2) 8.25 Re -Roof No Span 4 Sx (in."3) 7.56 Plywood Sheathing No San 5 Ix(in "4 20.80 Board Sheathing Solid -Sheathing Total Rake Span 11.21 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 0.92 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 7.50 ft Wood Grade #2 Rafter Slope 22° PV 2 Start Fb (psi) 900 Rafter Spacing 24" O.C. PV 2 End I Fv (psi) 180 Top Lat Bracing Full PV 3 Start E (psi) 1,600,000 Bot Lat Bracing At Supports PV 3 End E -min (psi) 1 580,000 Notes 1. ps = Cs'pf; Cs -roof; Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (C) (IS) p9; Ce 0.9, Ct=1.1, IS=1.0 Member Analysis Results Summary Governing Analysis Max Moment @Location Capacity DCR Result (+) Bending Stress (psi) 1,594.7 1 5.3 ft 1,547.3 103% Pass Member Loading Summary Roof Pitch 5/12 Initial Pitch Adjust Non -PV Areas PV Areas Roof Dead Load DL 6.5 psf x 1.08 7.0 psf 7.0 psf PV Dead Load PV -DL 3.0 psf x 1.08 3.2 psf Roof Live Load RLL 2 0. 0 psf x 0.95 19.0 psf Live/Snow Load LL/SL',z 30.0 psf x 1 1 x 1 30.0 psf 30.0 psf Total Load (Governing LC) TL 1 37.0 psf 40.2 psf Notes 1. ps = Cs'pf; Cs -roof; Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (C) (IS) p9; Ce 0.9, Ct=1.1, IS=1.0 Member Analysis Results Summary Governing Analysis Max Moment @Location Capacity DCR Result (+) Bending Stress (psi) 1,594.7 1 5.3 ft 1,547.3 103% Pass ZEP HARDWARE DESIGN CALCULATIONS - MP1 Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Framing Type / Direction PV System Type Zep System Type Standoff (Attachment Hardware) i 22' Y -Y Rafters SolarCity SleekMountTM ZS Comp Comp Mount SRV Section 26.8 Spanning Vents V-Ult No Fig. 1609A Exposure Category Wind Design Criteria Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method K;2f Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-24/B/C-5A/B Mean Roof Height In 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic Factor K;2f 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V12) Eq uation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down) GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up p„ -29.5 psf Wind Pressure Down p1d.—I 16.0 psf ALLOWABLE STANDOFF SPACINGS X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 41" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -328 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 59.9% X -Di rection Y -Direction Max Allowable Standoff Spacing Portrait 48" 62" Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -331 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 1 60.4% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP4 Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. of = 0.7 (Ce) (C) (I0 Pg; Ce 0.9, Ct=1.1, is=1.0 Member Analysis Results Summary Governing Analysis Pre -PV Moment (Ib -in) Post -PV Net Impact Result Gravity Loading Check 1,485.8 1,556.5 5% Pass Member Properties Summary MP4 5112 Horizontal Member Spans Overhang 0.32 ft Rafter Properties Actual W 1.50" Roof System Properties Span 1 10.07 ft Actual D 5.50" Number of Spans (w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A (in^2) 8.25 Re -Roof No Span 4 Sx (in.^3) 7.56 Plywood Sheathing No San 5 Ix in^4 20.80 Board Sheathing Solid -Sheathing Total Rake Span 11.21 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 4.08 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 7.42 ft Wood Grade #2 Rafter Slope 220 PV 2 Start Fb (psi) 900 Rafter Spacing 24" O.C. PV 2 End I I Fv (psi) 180 Top Lat Bracing Full PV 3 Start E (psi) 1,600,000 Bot Lat Bracing At Supports PV 3 End E -min (psi) 1 580,000 Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. of = 0.7 (Ce) (C) (I0 Pg; Ce 0.9, Ct=1.1, is=1.0 Member Analysis Results Summary Governing Analysis Pre -PV Moment (Ib -in) Post -PV Net Impact Result Gravity Loading Check 1,485.8 1,556.5 5% Pass Member Loading Summary Roof Pitch 5112 Initial Pitch Adjust Non -PV Areas PV Areas Roof Dead Load DL 6.5 psf x 1.08 7.0 psf 7.0 psf PV Dead Load PV -DL 3.0 psf x 1.08 3.2 psf Roof Live Load RLL 20.0 psf x 0.95 19.0 psf Live/Snow Load LL/SL''2 30.0 psf x1 I x 1 30.0 psf 30.0 psf Total Load (Governing LC) TL 1 1 37.0 psf 40.2 psf Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. of = 0.7 (Ce) (C) (I0 Pg; Ce 0.9, Ct=1.1, is=1.0 Member Analysis Results Summary Governing Analysis Pre -PV Moment (Ib -in) Post -PV Net Impact Result Gravity Loading Check 1,485.8 1,556.5 5% Pass ZEP HARDWARE DESIGN CALCULATIONS - MP4 Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Framing Type / Direction PV System Type Zep System Type Standoff (Attachment Hardware) KA 22' Y -Y Rafters SolarCity SleekMountTM ZS Comp Comp Mount SRV Section 26.8 Spanning Vents V-Ult No Fig. 1609A Exposure Category Wind Design Criteria Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method KA Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic Factor KA 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V"2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient (Down) GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up p„ -29.5 psf Wind Pressure Down down 16.0 psf ALLOWABLE STANDOFF SPACINGS X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 41" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -328 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 59.9% X -Direction Y -Direction Max Allowable Standoff Spacing Portrait 48" 62" Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -331 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 60.4% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. A NATIONALLY—RECOGNIZED TESTING CONIC CONCRETE LABORATORY SHALL LIST ALL EQUIPMENT IN DC DIRECT CURRENT COMPLIANCE WITH ART. 110.3. ECC EQUIPMENT GROUNDING CONDUCTOR 3. WHERE ALL TERMINALS OF THE DISCONNECTING (E) EXISTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, �4A, Wheat EMT ELECTRICAL METALLIC TUBING A SIGN WILL BE PROVIDED WARNING OF THE lCo�+MUN r pE„E„ �"�-�— FSB FIRE SET—BACK HAZARDS PER ART. 690.17. GALV GALVANIZED 4. EACH UNGROUNDED CONDUCTOR OF THE APPROVED GEC GROUNDING ELECTRODE CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY lia ce GND GROUND PHASE AND SYSTEM PER ART. 210.5. HDG HOT DIPPED GALVANIZED 5. CIRCUITS OVER 250V TO GROUND SHALL I p CURRENT CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B),Im 6. DC CONDUCTORS EITHER DO NOT ENTERIsc ZRevv1dforCodeCom SHORT CIRCUIT CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS ORD,te kVA KILOVOLT AMPERE ENCLOSURES TO THE FIRST ACCESSIBLE DC fir aaaminer kW KILOWATT DISCONNECTING MEANS PER ART. 690.31(E). nye iia p °o; tK ° P'ha lo%t won a'� of o"r""o01� lata LBW LOAD BEARING WALL 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN y/°qe olrr of the prov+stuns of Use ff+ald;wp code or of o^Y city ordi"onces. Ptlrts MIN MINIMUM RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY S Pft--Vt°Owe outhoimt° vtOJdft 01 come? the w�oftathe &N -V (N) NEW UL LISTING. °tk,.,o•d,naMetofthe city shall otdewfid NEUT NEUTRAL 8. MODULE FRAMES SHALL BE GROUNDED AT THE NTS NOT TO SCALE UL—LISTED LOCATION PROVIDED BY THE ,aye OC ON CENTER MANUFACTURER USING UL LISTED GROUNDINGIi,onye0e°lto PL PROPERTY LINE HARDWARE. yt "er,°"°' „ °L°"'' ,t"J" "CM, POI POINT OF INTERCONNECTION 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE••."°'r 'd'"0 of the owwwo °^s PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS. a' Igo `'"1Jihe0`°°`5 SCH SCHEDULE S STAINLESS STEEL 'r STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VICINITY MAP INDEX Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT WNEMA , 3R, RAINTIGHT ;; Sheet 1 COVER SHEET - Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS 1 Sheet 4 THREE LINE DIAGRAM eutsheets Attached LICENSE GENERAL NOTES - E 'er VZA t, TYPE EC # 8041 1. ALL WORK SHALL COMPLY WITH THE 2012 IBC AND 2012 IRC. r 2. ALL ELECTRICAL WORK SHALL COMPLY WITH _ , t THE 2017 NATIONAL ELECTRIC CODE. - ti r. MODULE GROUNDING METHOD: ZEP SOLAR t li REV BY DATE COMMENTS AHJ: Wheat Ridge - REV A MH 11/9/17 MOVED MODULES TO THE MAIN HOUSE i UTILITY: XCEL Energy (CO) CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER JB -8029178 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR BARBARA AMARASINGHAMMichael Barbara Amarasingham RESIDENCET Hart SL MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 2919 EATON ST 2.925 KW PV ARRAY Ridge PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WHEAT RIDGE, CO 80214 13.5 kWh Energy Storage System Wheat MODULES: THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN (9) SolarCity Standard #SC325 PAGE NAME SHEET: REV: DATE Building Qivison INVERTER: SOLAREDGE SE3000A—US—ZB—U PERMISSION OF TESLA INC. COVER SHEET 1 a 11/10/2017 LiIS=1 L LOZ/O L/ l l D Z 3LV0 A38 '-MHS }JDH I9Dg0lrj 03HS`dO SI 1NlHdIno3 d01831N1 it ` 1 L - 'J Old MV S1N3A ONIOnOOdd 1d3H 0 30N33 IVO 801d31N1 NO Nnd pnONO3 = _ d01d31X3 NO Nnd lInONOD --_ SNOLLVOOl 330ONVIS NM001nHS Old`dd asa d31]H W31SAS Ad 031`d3103O O S130VI ONINdb'M ?R d31N30 aVOl9I S130dl )R 13Ndd NOIln81d1sIO N011`dd3dO 3NOIV 0Nd1S dOl W31SkS lOVdOlS AOd3N3 ss3 S130VI ONINd'dM )R 133NNODSIO 0d ,,VIM DIIVNOlnV S130VI ONINd`dM ?R O3S10 DO 03lVd931Nl /M d31d3ANl ��1 13041 ONINd`dM )R d3134 Ailllln (3) 0 UN=lJ=l I tioTS T :,ldOlS albU14S CIWOD :]Vld3iVlN 6LT :H1nrlIZ`d ,,VddV 6LT :H1nWIZV ZZ :HDlld ),Vddd ZZ :H311d TdW 0 0 w I N Wd ITIS '3MVN 39Vd W@JSAS a6DJOIS A6JGU3 qp g•�1 J VMV Ad Mei 5Z6*Z 3ON301SId WDgbUISDJC)WV DJDgJD8 AdM]Ard(I (3) asnOH 40 Tu0JH ,00.50- ZZ: L 1 5: 1' 1 i'L i OZ :a . t1Z08 00 `3OGN 1VJHM 1S NOM 6162 AVHONISVdVWV VdV8dV8 n-oz-sn-VOOH3s # 3903dVIOS :a3La34Nl SZ£OS# PJDPUD}S A}IDJDIoS (6) S31f10ON }J9sUI-6UIgSD13 M M dwo3 SZ :KRSdS 9NLLNOOII 00 8L �6Z08-8P :msmnN9Or 'ONI VISM JO NOISSIV483d N31118M 3HL 1f10H11M '1N3VIdinO3 VEIL 3ALL03dS38 3HL 30 3sn ONV 3lVS 3H1 KLM NOLL03NNOO NI 1d3OX3 'NOLLVZINVDaO S.LN3ldlD38 3HL 30&nO Sd3HL0 Ol iSVd NI SO 310HM NI 03SO10SIO 38 11 I1VHS NON ''DNI VlS3L 1d30X3 3NOANV 30 IU3N38 3HL 80J 03sn 38 AN IIVHS 03NIVINOD N13a3H NOLLVV480JNI 3HL — IVILN3013NOD S TZ ,OT ,T 0 3 M T = „Z£/£ :aleDs N N` Id ITIS uezel uiassnH Aq paubis Allel!bia uiassnH (:A>- SIDE VIEW OF MP1 NTS MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 41" 62" 0'l STAGGERED 0" PORTRAIT 48" 19" RAFTER C.J. 2X6 @ 24" OC 2X6 @24" OC ROOF AZI 179 PITCH 22 STORIES: 1 ARRAY AZI 179 PITCH 22 Comp Shingle - Solid Sheathing X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. GRADE —� /— COMPACTED BACKFILL 6 " 1 _� UNDISTURBED SOIL RED WARNING TAPE W/ TRACE WIRE APPROVED BACKFILL SCHEDULE 40 PVC i TRENCH DETAIL CONDUIT T 1 Scale: 3/4"=1'-0" 0 L/C X&Z \t4 A• i r PE.0051052IF ; ■ a a zsa'm I. '� SIDE VIEW OF MP4 E NTS MP4 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 41" 62" 0" STAGGERED 0" PORTRAIT 48" 19" RAFTER C.J. 2x6 @ 24" OC 2X6 @24" OC ROOF AZI 359 PITCH 22 STORIES: 1 ARRAY AZI 359 PITCH 22 Comp Shingle - Solid Sheathing X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK ZEP FLASHING INSERT (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW (2-1/2" EMBED, MIN) (E) RAFTER SUBSEQUENT MODULES #_gArF77:7 INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER:J B-8029178 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR BARBARA AMARASINGHAM Barbara Amarasin ham RESIDENCE 9 Michael Hart T 5 L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 2919 EATON ST 2.925 KW PV ARRAY = n THE RECIPIENTS PART TO OTHERSEPT IN CONNECTION WITH ORGANIZATION, EXCEPT IN WHEAT RIDGE CO 80214 13.5 kWh Energy Storage System MODULES: THE SALE AND USE OF THE RESPECTIVE (9) SolarCity Standard #SC325 TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV. DATE: INVERTER: PERMISSION OF TESLA INC. SOLAREDGE # SE3000A—US—ZB—U STRUCTURAL VIEWS 3 a 11/10/2017 LLOZ/oL/LL D Wb OVIG 3NI] 33HHl n-oz—sn-do0023s # 30a38VlOS :U83% ON! VIS31 30 NOISSIY183d 31V0 31NN 3DVd N31110 3H1 1nOHLM '1N3HdlM3 VIS31 3AIL0363M 3H1 30 3Sn ONV 31VS 3H1 SZ20S# PJDPUD}S Al!3JDJoS (6) W@4S�(S a6DJo}S � bJaU3 �d��b �d uM� 5'� [ Mei 5Z6 Z 1[208 OO `3OQI� iV]HM 1S NOld3 6162 s3TSZ S1N3dlD38 3HLHIM O30GInO SSM3FNI Id30X3 �ILO 0118VOd NI 80 TION Ni a3S0I0S10 38 11 TIVHS `DNI liasul-6uiys013 M M dwo0 SZ Li "I s L }SDH 19o4DiW 3ONIGS3d WDgbUISDJDUJb DJDgJDO WdHONISVVhV V�VG�v83H1 :N31SAS DNLINnON MON VIS31 1d30X3 3NOANV 30 11J3N38 MOA a3sn 38 ION TIVHS 03NIVINDO 00 2L � 6 Z 0 8 -8 P :memnN NI383H Nol1VW803Nl 3H1 - lvuN30liNOO :020 :NOLIdWS30 :0WO 3SIN3Md 11Y3 .4/£ }!N }!nP-O (l) '04 2 ldM1n3N QP a 'Z-NMH1 DMV ( t ) �\ { tj ► 'Z-NMHL 'Ol# �'J ( •J 1143 .4/l-1 :}!Y }!npuoo t) - 003 —Ili 'Z-NMHI 'a# DMV ( l) O 'Z-NMH1 '£# .,. (.e�`3 X10018 DMV (l) �10D18 DMV (£ ) ___JJI���___III )o . 1143 .4/£ !}!N }!nPuob ( L) - 630/O93 uaaxJ 'Z-NMH1 '8# DMV( t ) - 1NI3 .*/£ :}!H }!npuo0 (l) 1143 .4/£ :}!H }inpu00 ( l) - 003 :)dV SZ'8 =dwI DGA OS£ = dwA 003 —19 'Z-NMHI/NHHL '00 DMV(l) O DdV SZ'8 =dwI DGA 0S£ = dwA u04JO 'Z-NMHI '011 DMV ( l) a}!4M 'Z-NMHL '01# DMV ( l) O DVV S'Z l =dwI DVA OtiZ = dwA lVdIn3N a84M 'Z-NMH1 '01# CMV( L) . Pad 'Z-NMHI '01# DMV( l) O Xv S l = xI DGA 009 = *:)OA )P018 'AO09 '9AM+ Ad '00 DMV (Z) JdV S I= xI XIA 009 = *DOA v0I8 'Z-NMHI '011 DMV ( l) Iao18 'Z-NMHL '01# DMV( t ) ZMd 'algo)Po}S 'O Aad - W19Tl'06—IS A6 -u3 B—H !VA)I9'S T100M d 0V d£ VV43N 'AO+Z/OZL 'VOOZ 'Ja}uaO pool 1S -0-00-L958011 i olsal(l) MOOZl04OZM8 # 1NVAM8(I) - (Da) A}nO pauao 'VW :}� 1oj}naN/punaO ( l) - saoodS Z 'dZ/VOZ !-M-j8 d£ MON !"03 /M xo8 ' *X.tX Zy :Io}ary OZZ88 # d3NIYWH-d3un0 (l) - 08 'dZ//VO£ :Rmme aN0£ODa 83HAVH-83unD saoodS Z d£ VA3N 'algsn3-u0N 'aoA06Z 'VO£ :}oauuoos!O 0£Z88 # d3NINIVH-M3unO( L) a BdntZZDO # 83NMVH-d3l1n0( l) DMV 0/1 - ZL# 'VOOI :jo}oauuoo dol ap!S-Pool 1NI-LL6iN i HNVBIIW(£)- OIVIOI 'O'ZMd 'ouua}uV /M D£ 41!M VN 'ASV 'O'ZMdOV J01 •AVM3IVD do- ya 9-00-tmlll / olsal(I) �a d3Z 'MOOT �az!w!} xograMod ^JJ M£ WON NZft* IN9-O04d 3Da38VlOS(6) / \U 'A009 'VO£ `}oauuoos!a �../ 88WnH # a 3Nvri6s l) V H ssal6u!d 'OS£ -9# b001 :}a�ooS �a}ayt v 619-lX-L084n # NNVBIIA(l) 9 uaddoO ' g x g/S saoodS Z 'dZ/VOOI �a�loaJ8 d08 pu-jo Z)- 00[zN8 i M3IYNNH-d3unO(l) IO dW31 NSW IV 00A XVw = *00A OZ 1d0dX3-NON '03d3134 AN '0V TT I I I I I I I I I I 3DIA83S Alnlln I 3SVHd 319NIS SaV01 3 OlI I AW/OZ101 I I Or '4oS 'DAd .4/£ •}!H }!np-0 ( t) - 039 ldla HOnOdH1 Sal X03 - 0o13a _ _ o z - 030I003 - H0N3dl W31S,lS I " 02 , 30bd01S ,,Od3N3 d Z, , N Z/ VN ------------------- -------------- ----- -- N r V YW 6XT :HW'TdW +oa L--- --- �a �J3 — 4NJ ---- -- ON`J -- --J O N — ----o- __ O - - - T ti Z N N Fz1VOOI loauuoos10 zi Aurz n a 3avnbs 8 dZ VOZ a SOVOI (3) Y v/ n-oz-sn-Vo0023S 3 dZ/VOOZ 39038VlOS E }oauuoos10 }amooS Ja}aW M3WWVH-21311no NNV011h d31N30 OV01 5 J,Vl3d ONIaIM (3) T aaIJanui 1NW dO VOOZ (N) 011VWO1nv b3HV3d8 llnodl0 NIVW dZ/VOOZ (N) 13NVd 301Ad3S NIVW VOOZ N d313LLN301 SW&S 00 3H1 NI NMOHS 3dV dwI ONV osl E ANI 919 :xowdA 9'69 :ooA 9ouoJ}u3 aoln.las puno.l6.lapun Z ANI 'd3Z A009 'ti0W '}aa4SMDD8 }yM 'waJ Mle 'YVWOti 'old S'90E 'MSZ£ 'alnPoW Ad IDJV '8Z PUD oos10 paon/M "%9'L6 'AO*Z 'M0,00£ 'aa;.lanul LLL06El:aagwnN J919VI MW 3181SN3A3dN1 HIMl3NVd 1V Mg # 03 3d ll SZEOS# PJopuo}S Aj!D IoloS (6) — V •138V1 n—BZ—sn—V000£3S # 3om3 VlOS ( l) — I ANI papunoj6un oO :l AuI ndW :jagwnN lauod ood ONnodo (N) 01 030 9# (N) ON08 3SN3DIl SD3dS 3lnaOW SD3dS 'd3 'd3ANI S31ON IV'd3N39 SD3dS 13Mdd NIVW SD3dS aNnodE) CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: INVERTER AND DC DISCONNECT - - - - - - - - - - - - - - - - - - - - - - - - - - I SOLAR PHOTOVOLTAIC ARRAYS) L- - - - - - - - - - - - - - - - - - - - - - - - - - J UTILITY SERVICE AC DISCONNECT PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE REOPIENT'S ORGANIZATION, EXCEPT IN CONNECTION MATH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: JB -8029178 0 0 MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert MODULES (9) SolarCity Standard #SC325 INVERTER: SOLAREDGE # SE3000A—US—ZB—U BARBARA AMARASINGHAM 2919 EATON ST WHEAT RIDGE, CO 80214 Barbara Amarasingham RESIDENCE 2.925 KW PV ARRAY 13.5 kWh Energy Storage System PAGE NAME-- SITE AMESITE PLAN PLACARD DESIGN: Michael Hart SHEET: REV: DATE: 5 a 11/10/2017 T=SLn uolloauuooJalul 10 lulod :(IOd) JajaW Allllln :(W) JoluaO peol :(Ol) loauuoosla Oa paleJ6alul gl!AA JalJanul :(ANI) llnpuoO and joualul :(OI) 00 loeuuoos!a Oa :(O(3) hued uolingljlsla :(a) �.o, �6�� X08 Jau!gwoO :(eO) � ,l A/r 3!npuoO:(0) moo' t0� loauuoosla Ov :(Ov) l9S lager 301A3a IN32iHn0�3AO SIHl 3iVOOl32i ION 00 Z'0'Z6'90L 03N NOIIO3NN00 :apoO gad lndino 2i3I213ANI (10d) J N I N JVM V : uolleool lageg bS'069 a3N WOO gad (IOd) (OV) uolleool lager a30NnObJNn NOIIISOd dd0 3HI NI 43ZIE) i3N3 8'£6'069 03N 39 AIHN STIS CIVO-1 (INV (INV(13aNmj9Nn 3NIl HIO9 NO SWNIN2i31 31 6'069 03 S-IVNINN31 HOnoiION Oa :apoO gad CRIVZVH >1OOHS 0Ri103-13 WOO gad (10d)(ov) (IOd)(ov) J N I N JVM V uolleool lager (ANO (Oa) bS'069 a3N WOO gad (IOd) (OV) uolleool lager a30NnObJNn a3ZJ2i3N3 38 AVA 8'£6'069 03N Sl 2AAI J3/WI (INV(13aNmj9Nn N3HM a3Sn 38 Ol 3bd n3ISAS 01b'I­1onoloHd :apoO gad (3)5£'069 O3N SIHI 30 S�IOI0n4NOO 00 3HI (10d)(ov) WOO gad (DAVZdH XDOHS 012A103-13 :uolleool lege-1 (ANO (Oa) JNIN?JbM V :uolleool lagel (0)99'069 030 :apoO gad (ANI) : uolleool lege-1 t,9'069 :apoO gad ad9sn9-�o AilOVdnd 4330X3 ION -nVHS 301A34IN32i n02i3AO kiddnS NIVN ONIanlOX3 'S301A30 IN3i i2jno 2OAO -nV d0 ONLY` l Tdloi S302inos 3�dlllnn AB aid IN3Ndln03 SIHI ONIN�JVMV £5'069 O3N :apoO gad (/WI) (Oa) uolleool lagel 8'£6'069 03N WOO gad (ANI)(Oa) :uolleool lagel C'9'6C'069 03N :apoO gad (er)(90)(0) :uolleool lagel solar=ee SolarEdge Single Phas For North America SE3000A-US / SE380OA-US / SE500W SE760OA-US / SE10000A-US / SE1140( ,,pv e r ter m .2.75 WariantY m i The best choice for SolarEdge enabled systems - Specifically designed to work with power optimizers — Superior efficiency (98%) - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 — UL1741 SA certified, for CPUC Rule 21 grid compliance — Small, lightweight and easy to install outdoors or indoors on provided bracket — Built-in module -level monitoring — Internet connection through Ethernet or Wireless — Fixed voltage inverter for longer strings — Optional — revenue grade data, ANSI C12.1 LISA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS - UK- ISRAEL -TURKEY -SOUTH AFRICA -BULGARIA www.solaredge.us solar=eeSingle Phase Inverters for North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / ....... ... ........ .... ................. ............... ................. .............. ............ ............... ............... ......... AC Output Voltage Min :Nom: Max.R) j J 211- 240 - 264 Vac ` ......................................... .................................................!.................................................. AC Frequency Min. -Nom. -Max 1'I 59.3 - 60 - 60.5 Hz .......................................................................... ........... 24 @ 208V 48 @ 208V Max_ Continuous Output Current..... ......12.5...... ......1.6.........21 25 ...240........... .............. 32...........42,@ 240............ 47.5...... A GFDIThreshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes I Yes INPUT Maximum DC Power (STC) 4050 5100 6750 I 8100 10250 13500 15350 .... �. ..... ................. I.................. W SE760OA-US / SE1000OA-US / SE1140OA-US ...... .................. Yes ........... SE3000A-US SE380OA-US SE500OA-US SE60WA-US SE760OA-US I SE10000A-US I SE1140OA-US OUTPUT Nom. DC input Volta a ......................... ....................I......../.....@..........................................,.......... 325 208V 350 240V Nominal AC Power Oui Output p 3000 3800 5000 j 6D00 7600 9980 @ 208V 11400 VA Adc Reverse-PolarityProtection .......................................... ............... .................1 ....... ....... ............... 10000,@240V. Maximum Inverter Efficiency ........... Max AC Power Output 3300 4150 5400@208V I 6000 I 8350_ 10800@208V 12000 I VA I W ADDi-10111AL FEATURES ,.,....... 5450 @240V ............. Revenue Grade Data, ANSI C12.1 , . 10950 @240V I 1 : : M AC Output Voltage Min --Nom- I Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 I IEEE 1547, Rule 21, Rule 14 (HI) Emissions 183 - 208 - 229 Vac INSTALLATION SPECIFICATIONS I 3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG ....................................... .. DC input conduit size / # of strings / .......................................................... ..... .............. ............ . % 1-3 strings % ........... ....... ... ........ .... ................. ............... ................. .............. ............ ............... ............... ......... AC Output Voltage Min :Nom: Max.R) j J 211- 240 - 264 Vac ` ......................................... .................................................!.................................................. AC Frequency Min. -Nom. -Max 1'I 59.3 - 60 - 60.5 Hz .......................................................................... ........... 24 @ 208V 48 @ 208V Max_ Continuous Output Current..... ......12.5...... ......1.6.........21 25 ...240........... .............. 32...........42,@ 240............ 47.5...... A GFDIThreshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes I Yes INPUT Maximum DC Power (STC) 4050 5100 6750 I 8100 10250 13500 15350 .... �. ..... ................. I.................. W Transformer -less, Un rounded ...... .................. Yes ........... Max. Input Voltage .................................... ... 500 Vdc Nom. DC input Volta a ......................... ....................I......../.....@..........................................,.......... 325 208V 350 240V ... Vdc Max. Input Current(') ... 16.5@ 33@208.. 208.. 9.5 13 18 23 34.5 Adc .................................... ......� ........... ..... 1............... .. 15,?.@ ................. ........ �................I..30;5 ,@ 240y.. ................... ........... Max. Input Short Circuit Current45 ......................................................................................................................................................... Adc Reverse-PolarityProtection .......................................... Yes ........................................................................................................................ . Ground -Fault Isolation Detection .......................................... 600ka Sensitivity ................ ................ ......... .................. . ................. ........... ........ ... Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % ........................................ CEC Weighted Efficiency .........� ..... ............... ...... ....... ... ............ 97 @ 208.. .. i ................ ....... .. .. 97 @ 208.. ..... 97. 1 98 I 97.5 97.5 97.5 ........... a 9' ......... 98 240.. 97.5 240.. .....I.......................@.........:................................ ... .. @............................ Nighttime Power Consumption I. <25 <4 I W ADDi-10111AL FEATURES Supported Communication Interfaces .................... _ i R5485, RS232, Ethernet, ZigBee (optional) ............. Revenue Grade Data, ANSI C12.1 ......................................................................................................................... ........... Optional"' .........tdovv ........................ Rapid Shutdown -NEC 2014 and .................................................... ................... Is! Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards . ....... ......... ......... IEEE 1547, Rule 21, Rule 14 (HI) Emissions ...... .... ... ......... ............. ... .... ...... .... FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG ....................................... .. DC input conduit size / # of strings / .......................................................... ..... .............. ............ . % 1-3 strings % ........... AWG range ..,..,. 3/4" minimum / 1-2 strings / 16-6 AWG 14,6 AWG. Dimensions with Safety Switch �_3/4'�.mi.n.lmum , 30.5 x 12.5 x 10.5 / in/ ..(HxWxD)...............................1....................... 30.5 x 12.5 x 7.2 /7 75 x 315 x 184........................ . ....,,,..775, x,315x260.............mm._.. Weight with Safety Switch. . ........... .......-..51...2./.2.3.2 ... ................... 54.7/24.7 88.4/40.1 Ib / kg... .... . .. ................ ............ Natural convection Cooling Natural Convection I andinternal Fans (user replaceable) fan (user ............... .replaceable)................... ................... Noise <25 dBA .......................................... Min. -Max. Operating Temperature .................................................................. ............ .............<.50........................ -13 to +140 / 25 to +60 (40 to +60 version available! °) ......... 'F / -C ..Rang?......... ................. ................................................................ ..... . Protection Rating ............................................................ NEMA 3R .......................................................................................... ............... ........... I[IForotherregionalsetdngs please contact SolarEdge support. I'I A higher current source maybe used; the inverter will limit its Input current to the values stated. n! Revenue grade inverter P/N: SExxxxA.-USOOONNR2 (for 7600W inverterSE7600A-US002NNR2). I"I-40 version P/N: SEmxA-US"NNU4 (far 76noW inverter:SE7600A-Us002NNU4). ISI P/Ns SExx A-USOxxxxxx have Manual Rapid Shutdown for NEC 2014 compliance (NEC 2017 compliance with outdoor installation) WV ZZ:lL 9102'6Z Ipdy :pa>Jodxa Ise! ale(] (] naa L00-6E9L-009 # luawnoo(] 'woo'sledsz :sddV pue s;ueled 'aogou Inoyl!m 96ueya of loafgns ale suogeogmadS asn yoea jo; slorpoid s JeloSdeZ;o 6lgpelms ayl 6u14uan Jo; opsuodsai Rlelos si Jewolsno ayl'dlueyem lonpwd alll ui of pawa;al suogeog!oads alas ayI salnlgsuoo slonpwd s,jeloS daZ Lp m padd!ys uogeluewnoop Jasn-pua alll 'lonpoid yoea jo; lqueLem Ionpoid uallum etjl w pau!eluoo s! /yueLem alas s,jeloS daZ 'SaoINaS jo slonpwd sli Inoge jo jeloS daZ 6q /lueLem ssejdxa Rue aleajo jou seop luewnoop sq L £OLZ In of poisll L6£ L -OSS 'oN 11ed ;ood 6u113na-1 q4 600-1£91-058 L96L-058 Jo 885L -O58 W) coo -LM -098 S9SL In of pois!l 096L-OS8 JO 989L-098 (l) zoo -LM -099 605L-098 *ON i1ed 'ON Pud L00-ML-058'ON 11ed dila aaiM o(i deo pua 6e-jjayseAA pomideo £OLZ In PUe L961n of paisil £oLZ In Oi paisfi £OLZ In of paisfi 1151-098 'ON Ved LZVL-098 J0 9091-098 ON Ved 8291-058 'ON 1Jed Zn daZ punojE) duE) Mosul 6uiyse1=1 £oLZ In of PIS!I £oLZ In of poise £oLZ In of paisn £L9L-098 JO 88£L-058 *ON Ped £1L0-009 JO 8091-098'ON Ved ££91-09VON fled )laolja}ul :PPls Aeaay MoolS 6ul;unoW I A6olouuoa1 builunoW Ad Janaj-1xaN woo-Jelosdaz s;uouodwoo WV ZZ: LL 9LOZ'6Z Judy :pelyodxa lsel ale(] (] AaH L00 -Ml -009 # juawnoo(] 'woo'sledsz :sddV pue sjusled 'aogou jncyl!m abueyo of loafgns aie suogeog!oadS 'asn yoea jo; slonpad s jeloSdaZ;o hl!1!gelins ay) 6Ulf4laA jo; apsuodsaJ dlelos si jawolsno alll 63uenem lonpold ayj w of pewa;aJ suoyeogioads alas ayl salnlilsuoo slonpold s,jeloS daZ qpm padduls uogeluownoop Jasn-pua ayl lonpoid yoea jo; Rlue»em lonpoid uellum ayI ut pau!eluoo si RlueLem alas s,jeloS deZ 'seowas jo slonpoid sp Inoge jo jelog daZ Fq 6lueLem ssejdxe due elesjo lou scop luawnoop siyl aeloSdoZ Aj!:)jejoS.�,_ ABolouyoal buijun0A Ad Iana-J-;xaN ® r slow alBwys uoilisodwoo jo} . dwoO SZ aejoSdaZ Aj!:)jeloS:�._ woo-Jeiosdoz saofnap 6wuoiiisod aJim Jol ggg L In of palsil sionpoid luewebeuew anm daZ „ qZ of do SJanalgueo pue .ZL of do sueds Jot pwaaw6u3 £OLZ In of Paisg In we slonpoJd 6uipuoq dwoC) SZ L96In PUe £OLZ In of Paisli In we slonpwd 6uipunw6 dwoo SZ spJepueis 0l -L Pue 90-L 3oS`d of >Jodej lauunl puM £OLZ In Jad 1sd og of sainssaid peol mous pue 14ildn puiM appow spoddns dwoo SZ Suoileivauo adeospuel pue Imillod ui s0e1sul slow pagoiid Jo; paubisa(] suoi;epi;i�adg 0usli in Z ad Jo L adJ(1„ se paiii m jainlaepuew Aue wwi salnpow 6uisn pallelsw uagm 6ullea wid „y„ sse10 COL l In a seq dwoo SZ puoq leouioala pue einiongs saleaao alempieq Paisil-In 6uipuoq olny `1ydwo, salnpoVI aigiledwoo daZ lie ylim s�joM slow al6wys uoiiisodwoo Jol uoflnlos 6wiunow Ad % uo1ldLJosea anti aeloSdoZ Aj!:)jejoS.�,_ ABolouyoal buijun0A Ad Iana-J-;xaN ® r slow alBwys uoilisodwoo jo} . dwoO SZ aejoSdaZ Aj!:)jeloS:�._ solarAW 2 SolarEdge Power Optimizer - Zep Compatible TM Module Add -On For North America P300-ZEP, P400-ZEP Compatible with Zep Groove framed modules — Certified Zep Compatible" bracket — Mitigates all types of module mismatch losses, from — Attaches to module frame without screws - reduces on -roof manufacturing tolerance to partial shading labor and mounting costs — Flexible system design for maximum space utilization — Power optimizer equipment grounded through the bracket — Next generation maintenance with module -level monitoring — Up to 25% more energy — Module -level voltage shutdown for installer and firefighter — Superior efficiency (99.5%) safety USA - CANADA - GERMANY -ITALY -FRANCE -JAPAN CHINA - AUSTRALIA -THE NETHERLANDS -UK -ISRAEL -TURKEY HUNGARY - BELGIUM - ROMANIA -BULGARIA www.solaredge.us solar' • o z SolarEdge Power Optimizer - Zep Compatible TI Module Add -On For North America P400-ZEP INPUT P3004EP (for 60 -cell PV modules) ; P400-ZEP (for 72 &915 -cell moduks) $....................................10......................18........... Vdc Dimensions including mounting bracket (WxLxH) RatedInput DC powerIll 300 400 W Absolute Maximum Input Voltage (Voc at lowest 128 x 152 x 27.5 /S x 5.97 x 1.08 128x152x35/ temperature) .......................................................................................... 48 80 _ .i.............. Vdc MPPT Operating Range ............. ... 8 - 48 8-80 Vdc Maximum Short Circuit Current (Isc) ............................................................................................................................................................ 10 10.1 ............ . Adc Maximum DC Input Current ............................................................................................................................................................................ 12.5 12.63 .............. Adc Maximum Efficiency ................................................................. 99:5 Weighted Efficiency .... ............. ...................... 98.8 .............................................................................I.............. .............. % Overvolta a Cate o .. g .. II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc _Maximum Output Voltage 60 I Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) _ _ Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC PaI115 Class B, IEC61000-6-2, IEC61000-6-3 T_ .................... .. 21091 class i safety)............... ... ... I.............. ............................................................... Safety IEC6.... class II safer UL1741 .............. RoHS i Yes INSTALLATION SPECI Maximum Allowed System Voltage _....... ...... . .... ........... .......i...._ 1000 ,...... ............. I ...... ..... ..... $....................................10......................18........... Vdc Dimensions including mounting bracket (WxLxH) 128 x 196 x 27.5 / 5 x 7.71 x 1.08128 x 196 x 35 / 5 x 7.71 x. 1.37 mm/in i........... .......................................................................................................................................................... Dimensions excluding mounting bracket (WxLxH) 128 x 152 x 27.5 /S x 5.97 x 1.08 128x152x35/ mm / in W ........................................................ 5 x 5.97 x 1.37 ....... Weight (including cables and mounting bracket) 720/1.6 .................. 840/1.9 I ...g....., k / Ib ............................................................................................................................................ Input Connector I MC4 Compatible ......... ......... Output Connector Double Insulated; MC4 Compatible ........... ... .I. / ........... ...... i Out ut Wire Len h 0.95 3 0 1.2 3.9 Operating Temperature Range -40-+85/ 40-+185 ........................... Protection Rating IP 68 / NEMA 6P ................................................................ . Relative Humidity................................................................................... 0- 100 ............... nl Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING A SINGLE PHASE THREE PHASE THREE PHASE SOLAREDGE INVERTERIzI HD -WAVE SINGLE PHASE 209V 480V Minimum String Length (Power .................................Optimizers)............................ $....................................10......................18........... - Maximum String Length (Power Optimizers) ..................................... . 25 2550 5700 (6000 with Maximum Power per String 5250 6000 12750 W ........................................................ i. SE7600H-US) ...................i.......................... ...................... ............ .............. ....... Parallel Strings of Different Lengths or i Orientations ........................................................................................................................................................ Yes I .................... Izl For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/aring_sizing_na.pdf. -- _- -- (3.99) 0�oE le yep 06 > w L canal asloN !13/59/ L LOZ an4oanCl SHoH bulleki aal6ad uo!lnllOd Ssk bul;eH u01le00j lam (luawpedwo0 6uu+m) 9Sd1 u01109uu00 puo (soiu.l0al3 �amcd 8 Aalleg) L9dl 5wleH ssaj6ul -- HE VW3N adAl ainsolou3 - pale] joopino pus joopul luawualAu3 (u EV96) w 000E u04ena13 wnw!xeVy leyu; %SZ :(3oS) 0jau3;o alelS wailno linej AlddnS wnwixeyy 6wsuapuoo-uou 'Ha %96 of do - (so L) )lead 'Jamod 1uaieddV (3,99 01 4.4-) 0,0£ 0; O,OZ- suo4lpuoo abe1o1S 6wsuapuoo'%DOL of do (HU) A;iPlwnH 6w;eiado (d.-ZZL of d-1--) O,OS o; O -.OZ- aln;ejadwal 6wlelado M 8'90 ww os L L , SNOIl'dOIdIO3dS WiN3WNOHIAN3 W 1 5 = 1 '(uI L'9)' (ul L'64 WW SSL Luw 99L luno. pem jo jooi3 suopda 6ullunayy (sql 9Le) 6)192; L 346!aM (u1 L'9 x ul L'6Z x ul £'SV) ww c,S L x ww SSL x ww OS L L suolsuawlp SNOUVOIdIO3dS-lV3IN`dH33W ':!-15-1 (46'4) SOOZ-£69 3331 '99 LOV olws!eS !13/59/ L LOZ an4oanCl SHoH leluawuonnu3 £00 5301 'H ssel0 S L ped 003 SODISalw3 Aliliq!ledwo0 apimplAoM u01109uu00 puo £ 9E Nn OVS6ln a6uey lndlno loloe j Jam0d £/6L In LbLI �n ZV9L In Su0geoylpa0 NOLVNd iOdNI dONdI-IdWOO V -LI na0 tC )r t -'uzo ll w arv�oa a6.et.s�p afl�2L� t^* E c 'd.L_, 3 s- .ol L' PIACX Serlen sieaA OL A;ue�.eryl %06 ,A0u910ly3 dul pun0H -- - A OS a6elloA Od M04BG )ewalul 99'0-/, (jamod paler-pn;) 96ue1j lope j lamod algelsnlpe 0' L -/+ a6uey lndlno loloe j Jam0d %00 L speo0 ase4d-pldS lo; aouelegwl y 0£ ao(Aap u0113010M luallnolan0 - ------ -� -- V ZE luanno llnej;ndlno wnwlxepy wailno linej AlddnS wnwixeyy (Alun a6leyoslp) VAr Z L - (so L) )lead 'Jamod 1uaieddV (a6leLy3slp pue 06leyo) VM 9 9 snonupoo Yew 70mod lua'eddV -- - --- (A1uo a6.e4oslp) Mm L (SOL) Bead 'MmOd lacy (061e40sip pue a6M43) AAAI 9 snonwluoo Yew 7amod IeaH 4W 9'EL -A61au3 algesn 4MA V L ABjeu3 18101 zH 09 Aouanbaij pug - - - - -ase4d 1pdS - --- adAl ul-paaj - - A 043/03 L -- (IeulwoN) 36ell0A OV SNOT VDHIO3dS 3ONVVA iOd2i3d 'jaMod uea)o 'a)gei(aj �o s;i}auaq ay} azi)eaj ((i(oinb o; sieuMo bullgeue 'pelsu( of As2a si pue (lisuep Abjeue 6wpea(-;ai.12w sanaiyoe u6isap pedwoo tieuo(;njonaJ s;j '6u(p(mq jo ewoy Aue of uo)joewoo aldwis a Sap)Awd aoepejui leoploa)a s,Ilemiemod -dn)(oeq pue '6u)l})ys peol uoi;dwnsuoo-j(as je(os jo} abeiols (6Jau9 sap)Aoid Noed fuelleq uoi-wnyl(l ajge96aegoa.l sli 'asn lepawwoo }L16p jo (epapisaj joj walsAs A.Ia;leq OV paleibalu(-1(pnj a si peMJaMod e(sal -1 -1bMH3M0d SC325 SolarCity ELECTRICAL AND MECHANICAL CHARACTERISTICS More powe IE r, With a sunlight to electricity More power per panel Max. power (Pmax) [W] Our 325W panel generates 20% more power than a standard conversion efficiency of over 19.4% 270W panel. the panel ranks amongst the More energy every year highest in the industry. That means More yearly energy (kWh) compared to other panels as they perform better in heat. Short circuit current (Isc) [A] the our panels can harvest more 15 Power tolerance [%]' Outstanding durability energy from the sun, which means With more than 20 additional tests performed beyond what is Solar Panel efficiency [%] currently mandated, these panels far exceed industry standards. it takes fewer of our panels to Temperature (NOCT) [°C] 44.0 More layers, more power power your home. Plus, they Manufactured by Panasonic for SolarCity, the panel uses Heterojunction cell technology, which adds a layer of thin film silicon generate more power output on top of high efficiency cyrstalline silicon. during the hottest times of the day, Leading warranty even in warmer climates. Our panels rank among the best in warranty coverage, with workmanship that extends to 15 years. ROHS V I—k� IEC81215 C Ve'IEC61700.2 C solarcity.com -- cL.,l ELECTRICAL DATA -0.258 Max. power (Pmax) [W] 325 Max. power voltage (Vmp) [V] 57.6 Max. power current (Imp) [A] 5165 Open circuit voltage (Voc) [V] 69.6 Short circuit current (Isc) [A] 6103 Max. over current rating [A] 15 Power tolerance [%]' +5/-0 Max. system voltage [V] 600o Solar Panel efficiency [%] 19.4 Note: Standard Test Conditions. Air mass 1.5: Irradiance = 1000W/m2; cell temp. 25°C e -Maximum power at delivery. For limited warranty conditions, please check our limited warranty document. TEMPERATURE CHARACTERISTICS Temperature (NOCT) [°C] 44.0 MECHANICAL DATA 41.46(1053: A INA Temp. coefficient of Pmax [%/°C] -0.258 Temp. coefficient of Voc [%/°C ] -0.235 Temp. coefficient of Isc [%/°C] 0.055 1 AT NOCT (NORMAL OPERATING CONDITIONS) 65.1 Max. power (Pmax) [W] 247.5 _ Max. power voltage (Vmp) [V] 54.2 R Max. power current (Imp) [A] 4.56 ml Open circuit voltage (Voc) [V] 66.1 Short circuit current (Isc) [A] 4.87 Note: Normal Operating Cell Temp.: Air mass 1.5; Irradiance = 80OW/m2 Air temperature 20'C; wind speed 1 m/s t AT LOW IRRADIANCE (20%) - Max. power (Pmax) [W] 62.0 in Weight: 42.99lbs Dimensions: 62.611/41.5r'/1.57" Connector: MC4 Frame Color: Black Snow load: 5400 Pa Wind load: 2400 Pa Fire Type: Type 2 E E mI1 _ �I zl 3ecss t Section A -A' I ml e �l :3 T Section B -B' Max. power voltage (Vmp) [V] 55.7 MATERIALS Cell material: m" � I 032 (8) DEPENDENCE ON IRRADIANCE I G a 3(669) 65.1 j c_ a, - in Weight: 42.99lbs Dimensions: 62.611/41.5r'/1.57" Connector: MC4 Frame Color: Black Snow load: 5400 Pa Wind load: 2400 Pa Fire Type: Type 2 E E mI1 _ �I zl 3ecss t Section A -A' I ml e �l :3 T Section B -B' Max. power voltage (Vmp) [V] 55.7 MATERIALS Cell material: Max. power current (Imp) [A] 111 DEPENDENCE ON IRRADIANCE Open circuit voltage (Voc) [V] 65.1 zoo - Short circuit current (Isc) [A] 1.21 000 i000w/m� Note: Low Irradiance: Air mass 1.5; Irradiance = 20OW/m2; cell temp. = 2S°Cvv 500 800w/m• Soo -- -- LIMITED Power output 10 years (90% of Pmin) WARRANTY 25 - ears ears (80%of Pril 4.00. fioow/m= - - - - - - ---- -- — ---- -- a - - -- — Workmanship: 15 years V 400W/m'_— MATERIALS Cell material: 5 inch photovoltaic cells 200 Glass material: AR coated tempered glass 200w/m' Frame materials: Black anodized aluminium 100 Connectors type: MC4 000 0 10 20 30 40 0 CAUTION! Please read the installation manual carefully before using the products. Panels are manufactured by Panasonic to the specification of SolarCity. Panels are only warranted by Panasonic If the panels are included In a PV system sold by SolarCity or Tesla. SolarCity and Tesla make no warranties solarcity.com related to the panels, which are sold as -is, SolarCity will handle any warranty claims on behalf of any purchaser. 50 60 70 so SolarCity ttdl 6ugeH ssaj6ul HE VW3N adAi a.msopu3 pale] ioopino pue icopul luawuw!nu3 (S £1,86) w 000£ uo!1ena13 wnw!xeyy buisuapuoa % OOL of do (HH) A ip!wnH bu!lejado (,-ZZ L of A,H 0'09 of O'oe- ainlejadwal bu!leAedo SNOIl'/:)IdID3dS 7d1N�IHNO2MNH (u! 6'17 L) Will SLE (u! V6Z) Will 04L luno- peM suo!ldo 6uilunopy (sgl 9E) 6>; t 9 L 146!aM (ul L9xw6tLxu! L'6Z) Luw 63 L x ww 9L£ x ww pt,/ suo!suew!Q SNOT VDHID�IdS _lVDINVHD�1H SNOIlVDI�IDddS �13NVNH 10ddi�ld -dde elsal aLll UlIM ao!Aap al!go W Aue w011 S9AaaSeJ A6jaus dn�{oeq a6eueLu pue asn A6jaua awoy JolluoW 01 noA 6ulmope'I!emJamod 41im Alloal!p seleownwwoo AemaleE) dn){oeg aul -aoueAlua ao!Alas ayl le pa!lelsu! aq ueo AemaleE) dmioe9 aLll'jaNLajq l!nojlo a Lallm paddlnba uayM'jamod dn�oea of u0111sueJ1 ssalweas a 6u!p!Aoid pue sebelno 6u!loalap Alleollewolne 'pu6 eLll of uo!loauuoo sioiluoo AemaleE) dmioeg aul -dn)loeq awoy-le!ied io awoy -aloum pue'6u!l4!L4s peol'uogdwnsuoo-;las je!os jol6uuol!uow pue luaw96euew A6Jaua saplAoid Iiemiamod elsa-Ljo; AemaleE) dn)!oeg ayl AeMa429 dof :)eq �-1b'M2i3MOd '-15=1 (4614) GOOZ-669 3331 '99 LOV o!ws!os uoileln6aH HOV3H O3/99/900Z angoanp k84Pq 4 .jLInpoy4 'n3/6l/exe aAiloa11O 333M 'n3/99/L Loe angoaAiO SH -U Ieluawu0JlAu3 Lv6917LOC N3 Z-69VLO£ N3 L-6917Lo£ N3 sapopy 6uileiado 176099 N3 £-9-000L9 031 — - aoeyauq lasn £00 S3OI 9 ssel0 9 L ued OOj suo!ss!w3 -uo!loeuuoo Appg4edwoo apimppoM pue L LID LZ'ZZO VS0 A1o6aleo a6e140AlanO 'L-6029031 LPLL'ln'Zt9LIn suo!leo!lweo NOIIVHbOANI 7lDNVl-ldH03 SNOIlVDI�IDddS �13NVNH 10ddi�ld -dde elsal aLll UlIM ao!Aap al!go W Aue w011 S9AaaSeJ A6jaus dn�{oeq a6eueLu pue asn A6jaua awoy JolluoW 01 noA 6ulmope'I!emJamod 41im Alloal!p seleownwwoo AemaleE) dn){oeg aul -aoueAlua ao!Alas ayl le pa!lelsu! aq ueo AemaleE) dmioe9 aLll'jaNLajq l!nojlo a Lallm paddlnba uayM'jamod dn�oea of u0111sueJ1 ssalweas a 6u!p!Aoid pue sebelno 6u!loalap Alleollewolne 'pu6 eLll of uo!loauuoo sioiluoo AemaleE) dmioeg aul -dn)loeq awoy-le!ied io awoy -aloum pue'6u!l4!L4s peol'uogdwnsuoo-;las je!os jol6uuol!uow pue luaw96euew A6Jaua saplAoid Iiemiamod elsa-Ljo; AemaleE) dn)!oeg ayl AeMa429 dof :)eq �-1b'M2i3MOd sleaA 0 L _.. A1ueljem sllemlamod poldnoo-OV 0 L of do slioddnS 4 .jLInpoy4 uogisueil dn>loeq ssalweas toy loauucosip oilewolnV uoge:adO dnmoee _— dnMoeq pue '6wgigs peal uondwnsuoo-llas jelos jol lioddns sapopy 6uileiado - - - -- - --- --- ddV elsal — - aoeyauq lasn _ —!j -IM ('J£) jelnllao lawa413 Al!A!loauuoO _- --� (% L -/+) ape16 onuanaH 1atON OV Ill A1o6aleo A1o6aleo a6e140AlanO pa1eH a3ueJlu3 ao�AJaS 'V OOZ-00L aoiAaO uogoelold 1ua11no18no VA 0L lue"no lmolp Vo4S indul wnwixen y 006 1uaiino loemaosq] zH 09 Pue 09 Aouanbaij pue ase4d 1!IdS 9 al6u!S _ adA_L ul-paaj A W/0ZI. 'A 0£Z (leu!woN) a6elloA OV SNOIlVDI�IDddS �13NVNH 10ddi�ld -dde elsal aLll UlIM ao!Aap al!go W Aue w011 S9AaaSeJ A6jaus dn�{oeq a6eueLu pue asn A6jaua awoy JolluoW 01 noA 6ulmope'I!emJamod 41im Alloal!p seleownwwoo AemaleE) dn){oeg aul -aoueAlua ao!Alas ayl le pa!lelsu! aq ueo AemaleE) dmioe9 aLll'jaNLajq l!nojlo a Lallm paddlnba uayM'jamod dn�oea of u0111sueJ1 ssalweas a 6u!p!Aoid pue sebelno 6u!loalap Alleollewolne 'pu6 eLll of uo!loauuoo sioiluoo AemaleE) dmioeg aul -dn)loeq awoy-le!ied io awoy -aloum pue'6u!l4!L4s peol'uogdwnsuoo-;las je!os jol6uuol!uow pue luaw96euew A6Jaua saplAoid Iiemiamod elsa-Ljo; AemaleE) dn)!oeg ayl AeMa429 dof :)eq �-1b'M2i3MOd STORAGE SYSTEM LABELS Label Location: Backup Load Center Per Code: NEC 408.4 Label Location: Backup Load Center Per Code: NEC 220 / Label Location: Main Panel Per Code: NEC 312.8(3) Label Location: Main Panel Per Code: N EC 705.12. D. 2.3. b Label Location: Main Panel Per Code: NEC 705.12.D.3 Label Location: Main Panel Per Code: NEC 705.12.13.3 Label Location: Main Panel Per Code: NEC 705.12.D.2.3.c City of , Wheat Ridge — itE I%N)A-W.z+ WSW (3W4mj rBa.L T BE is V� F g' DE m8iEFIT df gir,3E D-LEPT i .;iXi I�_, m:R AU R t+f � br#ii T m FDNC rCK, euu im gene � ei vkff r c,� uumz TFc q mwn :rrvma;ATm L3G�1 5E`rt 1 � 5 L 11 rim � � k =' DKr -T Ik E-nr-% 'qH lE '�+dE W ir� rAF TIE ;MMME SOUG ITf EOVI&T. 41+� -T TIE WM ?9_� .F StiRS' lay. INSPECTION RECORD CancellationsInsmust be ction online ubmt ed viahttp: http://www.ci-wheatridge.co.ushnspection Inspections will not be performed unless this card is Posted on the Pr nline form before 8 a.m. the day of he inspection Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the Project site PERMIT: �'7 ® M following business day ADDRESS: „ t l I � 7 t A J)— JOB JOB CODE:i—r Foundation Inspections Date Inspector 102 Caissons / Piers Initials Comments 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Inspector Date 201 Electrical/ Cable/ Conduit Initials Comments 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector 301 Rough Framing Initials 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 6 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Comments V r51 '-�- Baia.J ADDRESS. ��B CODE: ERMIT: �L Inspector ate ugh Inspection (continued) DInitials 3 Rough Mechanical Residential 7 Rough Mechanical Commercial 8 Boiler I Furnace 9 Hot water tank ?0 Drywall screw and Nail ?1 Moisture board / shower walls 22 Rough Grading 23 Miscellaneous anal Inspections W2 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* B ilding Final Inspection Inspector Date Initials Comments comments Inspections from these entities shall be requested one week in advance. lease *For landscaping and parking inspections p call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 418 u roved by PI before a Certificate of Occupancy anning, Public Works, Fire and Building Note: All items must be completedand issued. Approval of the Final Building Inspection does not th rization of occupancy. constitute au o permits please be sure that rough inspections are completed by the Fire District an For Low Voltage p Electrical low voltage by the Building Division. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Roofing PERMIT - 201708863 201708863 2919 Eaton ST Permit for reroof pitch ISSUED: 11/03/2017 EXPIRES: 11/03/2018 Install 26 squares Owens Corning Asphalt shingles 4/12 *** CONTACTS *** OWNER (303)993-6792 AMARASINGHAM SAHADHEVAN SUB (303)232-0324 Bill Lynn 019976 Mills Roofing Co./Decker Lane *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,360.00 FEES Total Valuation 0.00 Use Tax 259.56 Permit Fee 251.85 ** TOTAL ** 511.41 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. �r City of Wheat Ridge Residential Roofing PERMIT - 201708863 PERMIT NO: 201708863 ISSUED: 11/03/2017 JOB ADDRESS: 2919 Eaton ST EXPIRES: 11/03/2018 JOB DESCRIPTION: Permit for reroof: Install 26 squares Owens Corning Asphalt shingles 4/12 pitch I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications. applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorizcd by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction "ith this erm. I further attest that I am legally authorized to include all entities named within this document as parties to the work -to be perform ed. and-that—all- work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I _ This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees andprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of ff the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all re uired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. _b_ 1 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Antoinette Kulick 2d1'lo �gb From: no-reply@ci.wheatridge.co.us Sent: Friday, November 3, 2017 11:57 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address 2919 Eaton St Saha Amarasingham 3039936793 Field not completed. ,5,-1 1, t_t I Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed IMG 3158.JPG Contract CONTRACTOR INFORMATION Contractor Business Mills Roofing Company Name Contractor's License 019976 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-232-0324 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 2221 Gray St Edgewater Co 80214 (Primary address of your business) Contractor Email Address millsroofingcompany@gmail.com Retype Contractor Email millsroofingcompany@gmail.com Address DESCRIPTION OF WORK TOTAL SQUARES of 28 the entire scope of work: Project Value (contract 12360 value or cost of ALL materials and labor) Are you re -decking the No roof? Is the permit for a flat Pitched roof (2:12 pitch or greater) roof, pitched roof, or both? (check all that apply) K and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Robert Lynn Email not displaying correctly? View it in your browser. What is the specific pitch 4/12 of the PITCHED roof? How many squares are 26 part of the PITCHED roof? Describe the roofing Owens corning materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof. Provide any additional House detail here on the description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application 3 a cD o D. � N (r -D. (1 O 2. O 0 CL C Q. tfi 50 = C Z= o o °� = k o as � O 00 -t O CL g %0 at" 03 OO CL IN O N CD r N� '33 Op .,o O n O Q C 0. m O O� ps 0 N. n m V (Q (D o °� 3 P+ N SCCC n G � :1 L F� Rj is L on cD. D D0 0 O0 o n o C. x m 9) O o D x 1 0 to +�� z i J.A 3 (�) � N 0 m � s W \ \J t - I . C 0 G) m_ -t O n � c., r m n �� 3 � • D Fm (D _ r { D xr �i ♦lam ♦ N � o T Q CD r T c -a < C a z m t 0 V r G L ♦ 1 r mo D 2 r m h C m Z m O .iti •� O m m m m m � m D O 2 m D m z y r m <y 0 a v L on cD. D D0 � 0�'!ryq >Vf a 0 D M M m m CD m x m 9) O 0 to i J.A 3 (�) � N � s ci t I . C 0 �; -t O c., 3 (D _ ,O+ CD r X p)' z m CL 0 1/ Ai /(D y ) M z u m T m �>- � 0�'!ryq >Vf a 0 D M M �° im �A co PO m i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: _41 !100 F_ Job Address: Permit Number: ❑ No one available for inspection: Time 06'x'3 AM/' M Re -Inspection required: Yes No When corrections have been made, call f e-inspectji�on at 303-234-5933 Date: , Inspector: W �� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: j Job Address: l Permit Number: RYA ❑ No one available for inspection: Time AM 6M Re -Inspection required: Yes No ') When cl!orrelI on have been made, call forVz ction 30 234- 93 Date: 1� (� Inspector: DO NOT REMOVE THIS NOTICE City of tare: COMMUNITY DIFVELOPMENT**—�-'� PlinAllermit# Building Inspection Services Division 7500 W . 29th Ave., Wheat Ridge, CO 80033 Pian review Office: 303-235-2855 * e 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application .� «.- —va — title —1111. mulumpiaim awim, ions May not IXI processed.,*** Property Address: 2- w �� 01 Property Owner Email:' Address f 'Lras Architect/Engineer - ail: Phone. rpt ' mgr; � Contractors City Ucense Phone.- Contractor hone.-ontra for avail dress: � � e uContractors.* Electrical; ,A t Plumbing: Mechanical, W.k City License ## W.R. City License # W:k City License ## Cher City Licensed Sub: Other City Licensed Stab: City License # City License Complete all information on BOTH sides of this for' 2 • •. * r . � .... * +r a r.*:" G of materials to be used, etc.) Sq. FULF Stu's G lio Amps Square$ Other FOR OFFICE USE ONLY City of Date: Wh6at,R 4d ic C (Jul '�"'tg 7 OMMUNiTy DEvELopmtNT plan1permit # Building & Inspection Services Division Z- (D c) t -s) 7500 W. 29Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application M04*0i x (if different than property address) Address: City, State, Zip: Complete, all information on BOTH sides of this form El NEW COMMERCIAL x.p STRUCTURE ELECTRICAL wa SERVICE UPGRADE 0 NEW RESIDENTIAL \M a. OOFING 0 COMMERCIAL ADDITION 0 ROOFING We D • ADDITION 15.': 0 WINDOW REPLACEMENT w J COMMERCIAL i ♦w STRUCTURE RESIDENTIAL 1M♦ ACCESSORY Mxr (Garage, shed, MECHANICAL ( M!x REPAIR 111 1it REPLACEMENT r #! A i PLUMBING RB SYSTEM/APPLIANCE s • i+1x or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT AV- 2..r.+Y �- 8� ` "� 1 r Sq. FULF Btu's J901 10 Gallons Amps Squares Other - A . * Building Permit Application (Complate## highlighted IM Address: City, State, Zip: Al A Plumbing: t4 f,4 Mechanical: City License # City License # City License # /46LK4)( Co-p /,5c o o4-C 4 - RC,.,, 0 Wtle*jkw Wfustion: omidinu Guide Sling,le Family Residential Uncovered Decks and Porches �Dc Isectioll 1 1 FrfmW V Check one Sincyle Family Residential Uncovered Deck and Porches tll� air &, Handrail spvciticati"ll'sl lrn4- :Z9 1 4, 6 Q V-}- i, V-1 - ag APPROVED Sut) ject to Fead Wheat Ridge Budcfing r -rl, Daite um p I e '2 o -f k- ' ri: -o" I"'' D S J ro 1 & r Aj INSPECTION RECORD Occuroancy/TVOe INSPECTION REQUEST LINE: (303) 234 -5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 3:00 p.m. to receive an inspection the following business day. Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Monolithic Slab Reinforcement Caissons Concrete Encased Ground (CEG) Footing /Stemwall P.E. Letter Do Not Pour Concrete Prior To Annrnval Of Tho Ahnva Inenarfinnc Underground /Slab Inspections Date Inspector Initials Comments Electrical (Underground) Sewer Service (Underground) Water Service (Underground) Plumbing (Below/ In -slab) Date Inspector Comments omments Heating (Below / In -slab) �Sl�l \NIi�S�YL- 111�11UN& I ifelI I He Ire]i Ca�T- 7� \.T.rT�RT.T- TS7T.T.T -! Rough Inspections Date Inspector Comments omments Wall Sheathing Roof Sheathing Lath /Wall Tie Rough Electric Date Inspector Comments omments Rough Plumbing Rough Mechanical Gas Piping -. 1o7CLola id 110101:14 WA I A ire] I I /G\ 0 iTiriPF.l K91 i9-, • - Ui7Tril - V ri C-TM i • � Rough Framing Insulation Drywall Screw / Nail Final Inspections Date Inspector Comments omments Final Electrical Final Plumbing Final Mechanical -. Roof S s� Final Building / Frame Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303 - 235 -2846. For ROW and drainage inspections call 303 - 235 -2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. * *Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. occupancy Is Not Permitted Until A Certificate of Occupancy is Issued Protect This Card From The Weather 1 �. `+ CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office * (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type Job Address _ " Permit Number 11zP;7493' f !ter ✓e_. f. i. 4 ❑ No one available for inspection: Time M�_ Re- Inspection required: )�,� No .. When corrections have been made, call for re- inspection at 303 - 234 -5933 Date: 715'lea Inspector DO NOT REMOVE THIS NOTICE " 1 City of Wheat Ridge ] Residential Roofing PERMIT - 110705 PERMIT NO: 110705 ISSUED: 06/20/2011 JOB ADDRESS: 2919 EATON ST EXPIRES: 06/19/2012 DESCRIPTION: Reroof 25 sqs with Lifetime pabco laminate shingles * ** CONTACTS * ** owner 303/239 -8467 Sondra Cobb sub 303/424 -7663 J.R. Emrich 09 -0209 Reroof America Contractors LLC ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0525 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION.: .7,400.00 FEES a Permit Fee 172.60 Total Valuation .00�J Use Tax 133.20 a ** TOTAL ** 305.80 Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named wit?rix_ this document as parties to the work to be performed and that all work to be performed is disclosed in thi5edvcnw,en�t, and /or its' approved plans and specifications. Sig atu of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field in ec Signature f Building Offical Date INSPE ION REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. pF.WFIBgpq, City of Wheat Ridge Building Division • 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 235 -2857 c O Inspection Line: 303 -234 -5933 O LORA� Building Permit Application Date: Plan #: Permit #: KWPI WA s 0�-rl E -so d S T Property Owner (please print): app, jT�2 k �� o-j Phone: 2 ��1 • Mailing Address: (If different than property address) Address: '2 cl City, State, Zip: Vjj-�ri- T I � t o ¢3021 nnta'ctoz�: � tz�d� G�IVI �ZI c� G®r�61'T�- .�+,c= r Contractor License #: Phone: 'tea 7Co (a 3 s�6 offlft C a < Electrical City License #: Plumbing City License #: Mechanical City License #: Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space description): escpttOto o . rGOr�F� Square BTU's Sq. Ft-/L-Ft added: 20fjC= Construction Value: $ . (as calculated per the Building aluadon Data sheet) Plan Review (due at time of submittal): $ Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit Plans subject to field inspection. CIRLCE ONE:: (OWNER) CONTRACTOR r PERSONAL REPRE VE of ( NTRATOR) E PRINT NAME: bt6S� SIGNATURE: Dater DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number: 14666 Date: 10/21/02 Property Owner: DONALD G COBB Property Address: 2919 EATON ST Contractor License No. : Company: Phone: 303-239-8467 Phone: 1- PWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT i hereby certify that the setback distances proposed by this permit application are accurate, and ~o nlJt violate applicable ordinances, rules or regulations of the City of Wheat Ridge or ~ovenants, easements or restrictions of record; that all measurements shown, and allegations mad.;! are accurate; that I have read and agree to abide by all conditions printed on this ~pplication, and that I assume full responsibility for compliance with the Wheat Ridge Building FodB (U.B.C.) and all other applicable heat Ridge rdinan S, r ark under this permit. tOWNER)(CONTRACTOR) SIGNE DATE~ ,.,1- Use: Total: $3,500.00 $97.25 $0.00 $70.00 $167.25 Construction Value: Permit Fee: Plan Review Fee: Use Tax: Description: PORCH ON EAST SIDE OF HOUSE BUILDING DEPARTMENT USE ONLY ;mnng.~nient.:; Approval: OK/OM Zoning: R1-C I!-' ,,-y. ,,!-~!g ,,~,.. Approval: OK/OM Pubjj~~9rks;!iIIIrllr,ntS: Approval: SIC: Sq. Ft.: 10/21/02 10/21/02. PORCH CANNOT BE ENCLOSED IN ANY WAY. Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire jf (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. The issuance of moval of drawings and specificalions shall not be construed to be a permit for. nor an approval of. any violalion of the provisions 0 uil n ny other ordinance, law, rule or regulation. , (::~) PI (4) (S) (Ei) Construction Value: Permit Fee: Plan Review Fee: Use Tax: Total: ~~' WH,_, "/ ~ 0 - C> " ~ COL ORI><CP DEPARTMENT OF PLANNING AND DEVELOPMENT BillLDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH A VENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPLICATION (- Property Owner: Property Address: , Contractor License No.: \ Company: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do 110t violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and ail other applicable (Wheat Ridge Ordinances, for work under this permit. \IOWNER)(CONTRACTOR) SIGNED g~ If. ~ATEMJ? -C/ '1- \~eSCriPtiof1J ~~1- ~ Building Permit Number: Date: Phone: J t1? ~).. J. q ~ S if':' 7 Phone: ':J.Fit&, oCJ BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: O~ fi?r . ~I C. Oft:... ~ '1~tjN- - {ft'Jrt.+ PUBLIC WORKS COMMENTS: 6~lo~ in ev-rL CbC<-;I-- Approval: CT P/I.I/dZ- BUILDING COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Electrical License No: Company: Plumbing License No: Company: Expiration Date: Approval: - Expiration Date: Approval: k ~~~ /4,\...j.~}_':i_:!._I, (~ "y/ "'> ,.'/ A\ .~ ~ /_'1 Rr-Cr-" IrO \ 'j . t: A::.1 V- , q..l . L_t ! "~Jidentia!DJits1'''' ?0!"~ le.1 " \~~ .A.. ,/ Meoo'~l License No: ../~ " --< '. Company!'-:--___..-~ Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) Jfthis permit expires, a new permit may be acquired for a fee of one-half the amount nonnally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandownent has not exceeded one (I) year. If changes have been or ifsuspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspectortwenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the buildin odes or any other ordinance, law, rule or regulation. AP 1-' i. I Subject to Fieri i"', Wheat Ridge BUlL, "e' Datelf{Uj02- s.""1l1~-,, ,-, i( tI-,E ~;~ \ ~~ ~ ~~ ~ \\ ~ ~i:- ~ -- I U 1.'1-~ . = "" ...1 <<' - ". --.a ,\ 1$1 cf)~~ ~.~~. ./ ., "" - , ~ . o " 00 .5 ] = " ( ".. '6/97 ' Single Family Residential Patio Covers &" Carports DlrecUons ~ 1. Fill in the blanks with dimensions and materials which :2. q t rEA T C? ~ 6 T. I will be used to build the structure. Please print legibly. _ y-€- C. ' -":" I- () go ~ I 'f . 2. Indicate in the check boxes whtch details from page 3 will be used. Please note if any of the. sides of your carport addition are closer than 3'.0" to the property line, that side of the carport must be enclosed with a solid 1 hour fire rated wall as shown in Alternate Details B and C. You must however, keep at least two sides of the carport open to conform to the building code requirements. A zoning variance may be required. ~.OOf covering ~- aJK (sxample: Class A 3 tab shingles) Underlayment t-- (example: 2 layers 15# fe<<) ,.. j~ . 2xJ.Lrafters spaced~" O.C. (6X8mp/B: 2 x8 rafters spaced 24" D,C.) Overhang <:!J~"x~"beam (exsmplo' (2) 2'x10') .' . .......... Existi ng building , Span l' (example: 10'-3' Maximum rise 8" at door J Slope (for Alternate B only) Concrete Slab -.lL"x-1L"posts (example:4"x4') spaced apart (e_ple:6j Minimum Diameter Pier 8" . 31.0n ..: .minimum ..i~ Footing ~"x_" (for Alternate Conly) This handout was developed by the Colorado Chapter of the Inh~mational Conference of Building Officials as a basic plan submittal under the 1994 Uniform Codes. It Is not Intended to cover all cln::umstances. Check with your Building Department for additional requirements. 2 6/97 Single Family Residential Patio Covers &: Carports Cant. 2x ledger Remove existing fascia Secure to wall wnh 4'/,' x 318' bolts @ 16" e.c. Locate bolts to penetrate top plate or studs Note: Remove brick veneer or siding at top of wall before installing continuous 2x ledger (listing wall SCllid 2x blocking Galvanized metal posVbeam connector Galvanized column base wi 1 . spacer to concrete 8" minimum diameter concrete caisson ~ 31_0" minimum ~ I' 8" 'I This hsndout was developed by the Colorado Chapter of the Intemational Conference -of Building Officials as a basic plan submittal under the 1994 Uniform Codes. It is not intended to cover all circumstances. Check with your Building Department for additional requirements. Alternate Detail A Lap underlayment a minimum of 18" under existing roofing felts Solid 2x blocking Existing Roof Cont. 2x6 secured to existing roof w/4'12"x3!8' lag bo~s at each rafter or truss Alternate Detail B - One Hour Wall 5/8" type 'X' exterior gypsum sheathing Solid 2x blocking 2x cedar or redwood facia ) lS/8" exterior gypsum board soffit Galvanized metal posVbeam connector Exterior siding Bottom plate shall be treated wood or Foundation redwood Infill between posts wi 2x4's @ 16" O.C. Minimum 31/2") '1" concrete slab L Galvanized column base wi 1" spacer to concrete Tie siab to foundation wi 21.011 x 21.011 #4 bent rebar Check local building . t:lepartment for sweliing soils. caissons may be required. 3 I ! I'lli"" I , i , , I I i I ,J ".",~ --'-'r, 'L~L I I i i I i i i i i i IS \' 6"- ~~tf ~ ,~ .. " a ~ " <>. !, ~ S. ~ ~ k i' ~ ~ G ~ ! 5. 1----- i I i I J' - -...9> r " ::: J ? -11,'[ 11 ~, I ~I \ '&~ ~, ~ " \' ~, ),\ I , ! , f I \ ~ I- t i i , i i i i i i i i i I i I CO f 3i-tA I ~ 7'1 i':c:,. " '. ~~C\ ~ ~PARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 7847 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 9/25/98 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 ;i~'!"': Ii.. . 'I" II! 1):;"'> 111:',:" ~, f. i~ t '[ .' '~ h \fi; :r', w .,1: 1<',; IH T '{i.:::- r r:.,; '-'1 ,f1:.:r '( 'r~': ';'; ',,', ,-"';; -i:.,,;]' 'ti!i':'::<'! ~;' ; f ~ ; , i t :{ ",-., ,- Property Owner: Property Address: 2919 Eaton Street Contractor License No. : Company: . "1CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone: 239-8467 Phone: rtify that the setback distances proposed by this permit application are accurate, violate applicable ordinances, rules or regulations of the City of Wheat Ridge or "easements or restrictions of record; that all measurements shown, and allegations accurate; that I have read and B9ree to abide by all conditions printed on this iJl. and that I assume full responsibility for compliance with the Wheat Ridge Building .::a.c.) and all other applicable Wheat Ridge ordinances, for work under this permit. Construction Value: Permit Fee: Plan Review Fee: Use Tax: Total: $288.90 $22.00 $0.00 $7.22 $29.22 )(CONTRACTOR) SIGNED DATE Use: Re-shingle home with white three tab shingles BUILDING DEPARTMENT USE ONLY SIC: Sq. Ft.: (." '.; ! i'" J' ; " ~':':: ':"(.: :/t ~~:~!; ),:.4 ,c:\ ,...." , ;>~(::f.: J '1;; 'I' ; Walls: Roof: Stories: Residential Units: :I!~ I~': :":':1ili;:,!';"'-' ;;{~~&j:'i,r":'::: ....:'1 '1. . :11 i'~{ ! ,i T~;" I :_{',:r1;'l ,~q , r,~ i'~:.:I" .;: (~f 'C:{<~ ;:1::j;s': r ; ~:fit.. '\0 j I~i " ':;:~~::i:'i" .:1:; ":':S'I :1,: ~:.:.ji':r.,~ \'L%(:t; License No : Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: _:' This permit was Issued In accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning ; Regulations and Buildln9. Code of Wheat Rid~e, Colorado or any other applicable ordinances oftMe City. 0;' This permit shall expire if (A) the work authonzed is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. If this pe1'!1lit expires, a new pennlt may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or If suspension or abandonment exce&ds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceedllng with successive phases of thel'ob. The issuance of a parmi! or the approval 0 drawings and specifica,;ons shall no.'..pnstrUed to be a permit for, nor an approval of, any violation of the provisions of 'he building codes or any other ordinance. law. rule or regula';on. [/ 11 '->-.V'Y' tTi1.dd.A..A\ ~k Chief Building Ins$ctor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner-: ct;f-~ /.1. e-te-- Property Address: ;1..q [q ~ d. Contract.or License No. : CompallY : OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone:]03 - 2..:) q - 'j'l/,-'1 Phone: I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown. and allegations made are accurate; that I have read and 39.ree to abide by all conditions printed on this application. and that I assume full responsibility for comphance with the Wheat Ridge Building Code (u.a.c.) and all other applicable eat Ridge ordinances. for work under this permit. Construction Value:.2. rg tt/ 1 !I Permit Fee: Use Tax: (OWNEFl)(CONTRACTOR) SIGNED Total: $0.00 DATEt{~ :J.c;4g Use: Description: ~ ~ 4:;Jh ~~ ~~:tit~ BUILDING DEPARTMENT USE ONLY ~lrr~().mm1J.i.U$J Approval: Zoning: !3Jl:!RllnmcOmlnen..~ Approval: C!!.B1r~J~~K~_9JIJIJJ~n~ Approval: SIC: Sq. Ft: Ol;cupancy : Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval : This permit was issued In accordance with the provisions set forth In vapor application and Is subject to the laws of the State of Colorado and to the Zoning Regulations and Buildi09. Code of Wheat Rid~e. Colorado or any other applicable ordinances of the City. This permit shaU expire If (A) the work authonzed Is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned (0( a period of 120 days. . If U1is permit expires, a new permit may be acquiredfOl" a fee of one-half the amount normally required. provided no changes have been Of' will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid (or a new permit. No wor1( of any manner shall be done that will change the natural now of waler causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspectlons and shall receive written approval on inspection card before proceediing with successive phases of theiob. The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nof an approval of, any violation of the provisIons of the building codes or any other Qfdlnance, law, rule or regulation. (1) (2) (3) l4) 5) (6) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION