Loading...
HomeMy WebLinkAbout2626 Gray StreetPERMIT:X i ADDRESS: JOB CODE: INSPECTION RE RD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector CommentsInitials 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above inspections Underground /Slab Inspections Date Inspector CommentsInitials 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector CommentsInitials 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 3n4 c;;2 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS Rough Inspection continued g p Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 405 Final Mechanical Residential 319 Hot water tank —T -b 406 Final Mechanical Commercial 320 Drywall screw and Nail 407 Final Plumbing Residential 321 Moisture board / shower walls 408 Final Plumbing Commercial 322 Rough Grading 409 Final Roof 323 Miscellaneous 410 Final Window/Door Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential j - / _) —T -b 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. /Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. �Xo o 045q c*26ra V,,# PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Mechanic PERMIT - 201707459 201707459 ISSUED: 09/20/2017 2626 Gray ST EXPIRES: 09/20/2018 Residential mechanical replacement of 80% 70K BTU furnace, 50gallon/40KBTU water heater and 16SEER 2 ton AC w/rehook. *** CONTACTS *** OWNER (303)433-8646 MAYNER MELANIE SUB (303)466-4209 Rosalie Cooper 018111 Cooper Heating & Cooling *** PARCEL INFO *** ZONE CODE: I UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** A/C Replacement Furnace Replacement Hot Water Heater Total Valuation Use Tax ** TOTAL ** *** COMMENTS *** ESTIMATED PROJECT VALUATION: FEES 60.00 40.00 40.00 0.00 137.74 277.74 6, 559.00 *** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure.All work shall comply 2012 International Codes, 2014 NEC (if applicable), and ordinances adopted by the City of Wheat Ridge. Work is subject to field inspections. City of Wheat Ridge Residential Mechanic PERMIT - 201707459 PERMIT NO: 201707459 ISSUED: 09/20/2017 JOB ADDRESS: 2626 Gray ST EXPIRES: 09/20/2018 JOB DESCRIPTION: Residential mechanical replacement of 800 70K BTU furnace, 50gallon/40KBTU water heater and 16SEER 2 ton AC w/rebook. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans andprocedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Off tial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signatur 4=uiIding Official — _ 10 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wh6at Rdle C0"AM.tJt [TY DEVELOPMENT Building & Inspection Services Division 7500 W. 29`h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: / 7 Plan/Permit # � 0 7 / 7 Vy� Plan Review Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Y Property Address: Owner Property Owner Mailing Address: (if different than property'address) Architect/Engineer- Archtect/Engineer E-mail: Phone: Contractor: Cooper Heating+ and Cooling Contractors City License'#; �� Phone: 720.361.4245 Contractor E-mail Address: kmekinney@eoopergreenteam.com Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form !es or made are fiance gat owner eany rri 1 V (Check aU t api I NEW j. NEVf'. M CIAL STF UCTL S STR CTU .y) ❑ ELECTRICAL SERIAICE UPGRADE ❑ COMMERCIAL. . ROC}FING COIWI CI '�ADpmo ❑ RESIDENTIAL ROOFING RES ADDITION ❑ WINDOW REPLACEMEMT' i COM C ACICESSCDRY S UCARE (Garage, shed, deck, etc.) SI MEC ' i4CCE RY S IC SYSTEWA►PPL : UC (Garage, shed, deck, etc.) CE AIR or REPLACEMENT LU G Y;TEM/APR RE? R or REPLACMENT ELEC C = SYSTEM/AP E AIR or REPLACEMENT OTf i !es or made are fiance gat owner eany ILL CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ��® S� ., 1 /')I �c Job Address: S 4 - Perm it - Permit Number: o 1 -7 o -7 Ll S9 l a4 LyA_eale n ❑ No one available for inspection: Time 1:�_2.; Ll AM/ Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date:-/ 1 64 Inspector: `r -b DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE rr Inspection Type: r� Job Address: erg S Permit Number: 20/7 7g5I ❑ No one available for inspection: TimeAM/PMS Re -Inspection required: Yes, "'No When corrections have been made, call for re -inspection at 303-234- Date://-/-5,)7 03-234- Date: -5' % Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time = t' ASM/PM Re -Inspection required: Yes ---No When corrections have been made, call for re -inspection at 303 -234 - Date:,, /'� Inspectors:-� DO NOT REMOVE THIS NOTICE ro- City of Wheat Ridge Residential Roofing PERMIT - 201701880 PERMIT NO: 201701880 ISSUED: 06/11/2017 JOB ADDRESS: 2626 Gray ST EXPIRES: 06/11/2018 JOB DESCRIPTION: Residential Reroof: Removing 3 layers and replacing with Owens Corning Duration Storm asphalt shingles on both main house and detached garage. 5/12 pitch, *** CONTACTS *** OWNER (303)433-8646 MAYNER MELANIE SUB (303)295-2220 Tomas Wofram 110052 Core Contractors, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,600.00 FEES Total Valuation 0.00 Use Tax 138.60 Permit Fee 156.75 ** TOTAL ** 295.35 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€lms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201701880 PERMIT NO: 201701880 ISSUED: 06/11/2017 JOB ADDRESS: 2626 Gray ST EXPIRES: 06/11/2018 JOB DESCRIPTION: Residential Reroof: Removing 3 layers and replacing with Owens Corning Duration Storm asphalt shingles on both main house and detached garage. 5/12 pitch, I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I an the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attes} that I am legally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date y, REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION �FOLLOOWfXNGC,A=�XNESS DAY. Inspection time requests will be accepted by email only. Please email re terA w 'eatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the a inspection in subject line. Agreement "Doing it right matters" CONTRACTORS ROOFING SYSTEMS Property Owner Effective Date Melanie Mayner 05/15/2017 Property Address 2626 Gray st City/State Zip Wheat Ridge 80214 Primary Phone number Secondary Phone Number 303-433-8647 Email Address melmayner@gmail.com Terms: 4501 Logan St, Denver, CO 80216 303.997.1559 By signing this agreement, the Property Owner authorizes CORE CONTRACTORS, INC ("CORE") to perform the work and supply the materials as agreed upon by Property Owner's insurance carrier. Homeowner agrees to use CORE exclusively, and authorizes CORE to obtain labor and materials in accordance with the scope agreed to by the insurance company and the specifications set out in this Agreement to accomplish the replacement or repairs. The initial proposed scope of services is attached to this agreement. This agreement does not obligate the homeowner or CORE in any way, unless the damage is approved by homeowner's insurance carrier. Roofing Scope: The roofing system replacement includes all shingles, underlayment, valley Additional Roofing Scope Notes linings and miscellaneous flashings, per local applicable municipal code. This Multiple layers also includes full clean-up of the property. A 5 year Roof Workmanship Warranty included on full roof replacement only. A one year workmanship warranty included all non -roof Due to the nature of repairs related to insurance claims, this contract includes an estimated repair price of the roof system, approximately S 11000 Because the final scope has not been agreed upon with the insurer, this repair price might change. The amount of this contract is for 100% of the replacement cost approved by the insurance company for work to be completed by CORE. Reaching agreement on the full scope of repairs involves considerable time on CORE's part; we will not proceed with that phase unless you agree to allow us to do the work once the scope is agreed upon. By signing this contract, you authorize CORE to reach agreement on the scope of repairs on your behalf. CORE agrees to bid the work using the primary insurance industry pricing database (Xactimate) based on the scope of work agreed upon with your insurer. You, the homeowner, recognize CORE CONTRACTORS, Inc, as a general contractor and as such shall be entitled to overhead and profit, at customary insurance industry rates (20% on Xactimate line items). Any substantial additions or deductions to the scope of work will be handled on the Customer Verification Form. Property Owner agrees that if a scope of work and project cost is agreed between CORE and the insurance carrier, that they are responsible to pay ONLY the deductible amount per their replacement cost insurance policy. Any further changes, in addition to the insurance work, must be requested in writing, by Property Owner. If, you, the Property Owner, plan to use the proceeds of a property and casualty insurance policy issued pursuant to Part 1 of Article 4 of Title 10, C.R.S. to pay for roofing work, pursuant to Section 6-22-105, C.R.S., THE ROOFING CONTRACTOR CANNOT PAY, WAIVE, REBATE OR PROMISE TO PAY, WAIVE OR REBATE ALL OR PART OF ANY INSURANCE DEDUCTIBLE APPLICABLE TO THE INSURANCE CLAIM FOR PAYMENT FOR ROOFING WORK ON THE COVERED RESIDENTIAL PROPERTY. PAYMENTS ARE TO BE MADE: %z (OR FIRST INSURANCE CHECK RECEIVED — ACV CHECK) UPON DELIVERY OF ROOFING MATERIALS, AND BALANCE UPON COMPLETION OF WORK. WORK TO BE COMPLETED WITHIN APPROXIMATELY 90 DAYS OF EXECUTED CUSTOMER VERIFICATION FORM. CORE SHALL HOLD IN TRUST ANY PAYMENT FROM THE PROPERTY OWNER UNTIL THE ROOFING CONTRACTOR HAS DELIVERED ROOFING MATERIALS AT THE RESIDENTIAL PROPERTY SITE OR HAS PERFORMED A MAJORITY OF THE ROOFING WORK ON THE RESIDENTIAL PROPERTY. Property Owner's Initials A�,_ /�_� Right to Cancel You, the homeowner, have the right to rescind this Agreement and obtain a full refund of any deposit within 72 hours after entering the Agreement. If you plan to use the proceeds of a property and casualty insurance policy to pay for the roofing work, you may rescind this contract within 72 hours after you receive written notice from the insurer that your claim has been denied in whole or in part. Property Owner Date Melanie mayner 05/15/2017 Property Owner Signature Insurance Company Auto owners „�0 Vl R Eit ^Y Cta' Iiva,- LS i4 tl- kt14 irie li cEailt i ORE CONTRACTORS, INC ("CORE") is authorized to provide you with this NOTICE. You are therefore notified that: (a) ANY PERSON OR COMPANY SUPPLYING LABOR OR MATERIALS FOR THIS IMPROVEMENT TO YOUR PROPERTY MAY FILE A LIEN AGAINST YOUR PROPERTY IF THAT PERSON OR COMPANY IS NOT PAID FOR THE CONTRIBUTIONS. 1. All contracts are subject to approval of our credit department and office without exception. The person executing this contract must obtain the approval from the officer of the CORE CONTRACTORS, INC. for this contract to be effective under any conditions. 2. SHOULD DEFAULT BE MADE IN PAYMENT OF THIS CONTRACT CHARGES SHALL BE ADDED FROM THE DATE THEREOF AT A RATE OF ONE AND ONE HALF (1 ''/2) PERCENT PER MONTH (18% ANNUM) WITH A MINIMUM CHARGE OF $20.00 PER MONTH, AND IF PLACED IN THE HAND OF A COLLECTION AGENCY, ALL COLLECTION, LEGAL, AND FILING FEES SHALL BE PAID BY CUSTOMER ACCEPTING SAID CONTRACT. 3. CORE CONTRACTORS, INC. shall have no responsibility for damages from rain, fire, tornado, windstorm, or other perils, as is normally contemplated to be covered by home owners risk insurance or business risk insurance, or unless a specified written agreement is made therefore prior to commencement of the work. 4. Should legal action be necessary because of any act that might arise during the course of this Agreement, CORE shall be entitled to all costs incurred in connection with such action, including a reasonable Attorney's fee. 5. The parties hereto agree that all actions or proceedings arising in connection with this Agreement shall be tried and litigated exclusively in the State and Federal courts located in the County of Denver, State of Colorado. 6. Replacement of deteriorated items (such as decking, fascia boards, roof jacks, ventilators, flashing or other materials) not covered by insurance, discovered during construction and required by governing code or necessary for product warranties are NOT INCLUDED and will be charged as an extra on a time and materials basis unless STATED IN THIS CONTRACT. 7. CORE CONTRACTORS, INC. shall not be liable for failure or performance due to labor controversies, strikes, fires, weather, and inability to obtain materials from usual sources, or any other circumstances beyond the control of CORE CONTRACTORS, INC. whether of a similar or dissimilar nature. 8. Subsequent to property owner's insurance carrier approval, if this agreement is terminated by the Owner, the Owner shall be financially responsible for all work performed based on the following milestones (percentages are additive). a. Consulting Phase: Preparation of CORE Xactimate scope of work and adjuster appointment — 3% of total bid. b. Substantial agreement or scope confirmation with insurer — 5% of total bid. c. Ordering and scheduling of work — 2% of total bid. d. Repair Phase: Any line item of physical work that has been started shall be completed by CORE; if the owner terminates this agreement while physical work is ongoing, they shall be responsible for all costs related to that line item, plus general contractor overhead and profit. 9. In addition, the Owner shall be responsible for all other reasonable fees and expenses incurred prior to termination of the agreement, including permit fees, deposits paid by CORE to suppliers and subcontractors, subcontractor fees and expenses, etc. to the extent they are not already included in the line items for work that has been completed. All fees and expenses incurred prior to termination of this agreement shall be paid by the Owner within 30 days of invoice date. 10. If material has to be reordered or restocked because of a cancellation by the customer; customer will have to pay the restocking fee assessed to CORE by the supplier. 11. If any provision of this contract should be held to be invalid or unenforceable, the availability and enforceability of the remaining provisions of this contract shall not be affected thereby. 12. ANY REPRESENTATIONS, STATEMENTS, OR OTHER COMMUNICATIONS, NOT WRITTEN ON THIS CONTRACT ARE AGREED TO BE IMMATERIAL, and not relied on by either party, and do not survive the execution of this contract. 13. The maximum liability for CORE CONTRACTORS, INC. shall be the original cost of labor and materials for the repair which customer agrees shall be liquidated sum, under any event of default of CORE CONTRACTORS, INC. herein. 14. During the duration of the work the customer's HOMEOWNER'S INSURANCE will be responsible for any interior damage as long as CORE CONTRACTORS, INC. has taken appropriate action to protect the roof and siding during the repair of the roof and/or siding. 15. CORE CONTRACTORS, INC. is not responsible for existing construction problems of customer's home. If pointed out and notified to CORE CONTRACTORS, INC. we will try to assist you in correcting the existing construction problems on a time and material basis. 16. THIS CONTRACT IS COMPOSED OF THIS PAGE AND THE REVERSE SIDE OF THIS PAGE AND SHALL BE CONSIDERED THE ENTIRE CONTRACT BY THE PARTIES. "UVJi RP �i F5TC�vf1rfJs Y u'tVV E}i.ciflt iS Litil'< � '- " Antoinette Kulick From: no-reply@ci.wheatridge.co.us Sent: Thursday, June 8, 2017 9:38 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application C� Residential Roofing Permit Application u This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come 1 s to City Hall to submit an application in person. Permits are processed and issued in C% the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being �. processed within 24-48 hours, subject to change based on volume. f For all other requests: CJ Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Existing permits that require amendments (dor example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. PROPERTY INFORMATION Property Address 2626 Gray St Property Owner Name Melanie Mayner Property Owner Phone 303-433-8647 Number Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name Core Contractors Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number 110052 303-295-2220 Contractor Email Address docs@coredoes.com (permit pick-up instructions will be sent to this email) DESCRIPTION OF WORK Is this application for a new permit for a residential roof? Are you re -decking the roof? Description of Roofing Material How many squares of material? Yes No Owens Corning Duration Storm 22 0 Provide additional detail Removing 3 layers and replacing with asphalt shingles on both here on the description of main house and detached garage. 5/12 pitch. work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract $6,600.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a 0) permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Tomas Wolfram Email not displaying correctly? View it in your browser. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number:O ❑ No one available for inspection: Time A AM/PM� Re -Inspection required: Yes ;No When corrections have been made, call for re -inspection at 303-234- Date:- '? Inspecto` r I� DO NOT REMOVE THIS NOTICE i -V '1n►1'n IG I-'� ( GW I o,�' � 66fib�'REr"CO V ��, INSPRD rib INSPECTION REQUEST LINE: (303) 234-5933 Occupancy/eke3 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Concrete Encased Ground (CEG) Foundation / P.E. Letter Fire Inspection / Fire Protection Dist. Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Initials Comments Electrical Comments Sewer Service Plumbing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. Mid -Roof Fire Inspection / Fire Protection Dist. Lath / Wall Tie Final Electrical Rough Electric Final Plumbing Rough Plumbing/Gas Line Final Mechanical Rough Mechanical Roof Rough Framing Final Window/Doors Insulation Final Building Drywall Screw/ Nail NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. **For Inspection Time Window Requests — Please email insptimereouest(cD-ci.wheatridcie.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: f- F ( s 'EIn Job Address: 5r Permit Number: 70J 019 1 2 ❑ No one available for inspection: Time t 4 A PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: 2-9 -1i Inspector: eta. DO NOT REMOVE THIS NOTICE 301ION SIHI 3AOn3b1ION OO }a, :ao1oadSul ££69-ti£Z-£o£ le uo/jo&dsgl-9j jo{ ileo &pew ueeq &neq suoljoejjoo uegM ON !ad) :paainbaa uoiloadsul-aa INdIqV--j-0— �• quail :uoijoadsui aol algLol!UAe quo ON ❑ :aagwnN }ivaaad :ssaippd qof :adAl uoi}oodsul 331ION N01103dSNI xe-4 6068-zco (£o£) • avio 558z-5sz (Cos) null uoljoadsul EE65-tiEZ (EOE) �')' uoisinia uoi�oadsul 6uipipe 3Jala iv3HM d0 AIM A City ft. COMMUNITY " V LOP Pl n1F'err»it t 1.p � " � . Building & Inspection Services Division 7500 W, 29th Ave., Wheat Fridge, CO 8 033 Plan Review Office: 303-235-2355 * ex: 303-237'-3929 ` Inspection tine; 393-234-5933 Email: errnits ci:uvheatrid e,cca.s PAID Building er it Application 1. � ��yN� mw raw Property Address. Lo Property Owner (please print). phaco Property leer mail: lel 1 0 Mailing Address: (if different than property address) Address: s City, State, ArchitectfEngineerE-mail.- Phone.* Contractors Oily License � � � Phone.- 7 Z0) Contractor E-mail Address: � � � � � � � . � LI � , Sulo Contractors: : Electrical: Plumbing: mechanical: W.R. City license W.R, City License # W,R. City License ## Other C4 Licensed Scab. Other City LicensedSub: City License # City License # Complete all information on BOTH sides of this form COMMERCIAL ® RESIDENTIAL Delcription 2 ork: (Check all that apply) NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION ITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT" COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck,etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEMtAPPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT kount of materials to be used, etc.} U0 IA Sq. FULF Stu's Gallons Amps Squares Other 605.11.3.2.1 Residential buildings with hip roof lay outs. Panels / modules installed on residential buildings with hip roof lay outs shall be located in a manner that provide a 3 foot- wide clear pathway from the eave to the ridge on each roof slope where panels and modular are located. The access pathway shall be located at a structurally strong location on the building capable of supporting RMIN =-- MMU= 60511.3.2.2 Residential buildings with a single ridge. Panels/modular installed on residential buildings with a single ridge shall be located in a manner that provides two, 3 foot —wide access pathways from the eave to the ridge on each roof slope 605.11.3.2.3 Residential buildings with roof hips and valleys. Panels/ modular installed on residential buildings with roofs hips and valleys shall be located no closer than 18 inches to a hip or a valley where panels or modular are to be placed on both sides of a hip or valley. Where panels are to be located on only to be placed directly adjacent to the hip or va ey. Exception: This requirement shall not apply to roofs with slopes of 2 unit's vertical in 12 unit's horizontal (2:12) or less city of , Wheat Rig. ]ELECTRICAL DATA@ STC REC26STP PR6CZ70TP REC27STP i3CC2SO C ORAL A AI x ELECTRICAL DATAMCT REC26STP REC2 OOP REC2 STP C2601P t Axt�9t��9RA�'�t�6 CERTIFRNTY ICATIONMARA womw a t ae "s� Single for North America solar =es -a SE300OA-US SE3800AdJS: p, ....E , S PJI SE3 ; US 'SE AA-US I SE A us SE ids a l x tl5 3 S 1 . a ........ .. 9980@208V Nominal AC Power flnxtpatt 3 3800 � 11 VA ri4dDL Max. AG Prewar Outputf 331 J 4150 5400 i6gV. ..... b3S 10800 208V 120VA r S45CI Z4UtB + iCi}5U 4t7Er' , ACi3astprrk.Lcl a €n, Nom Max,4) 183 208 - 229 Vac .,., .s,.... ,......., AC Output Voltage Min. Nor r,Max s4 } V � 211- 2401- 264 Lac � ., AC Freto"ry !Niko Isom Mox M 59.3 60 60.5Hz . 2 2ti IV 48 @ 208V Max. Continuous Output Current r 125 16 25 32 � 47 5 A . ?K ..., :� .�. ...�... , l.. 2 s,z �.,r.... „ �, ,... ... .... GFCIIThresfscald � ,..�.. .,.. ... ,.,...� .!�'. iJtilaty ohitor�rag islaradrng Prtectkon Count Cctnii uaabEd Threshra9afs Yes Yes INPUT" axem DC ponver 5lCj 4050 5100 6750 „ 8?G4i 10250 135 } 9,53513 W Franarnnr ias ilnraasadrl Ye ! In ut tofiaSe5W Vde iVoan C3 Irtlattt f? 16.5 e..... 2,0 33 20 325 @ 208V } 350 2 V do :.,.., ,.,. Max, !repot Currentaxa f 9.5 13 18 23 34,5 Acle 30?;30.5 ? „� .. .. „ . , ... . . Sax. lnputShort C€rcud Current Adc Ree arse & aBarlty Protection . Yes e Ground-Fault Isolati on D election 00ku5en ittrrdty.. .. .. n Ma'am u€ranvrter Efhcaeny -97-7, 98,2 38.3 98 398 38 9i3 37 a t78Y 32 208e , CCC Weighted Effieir ricy 3i 5 98 97's 37 5 : 97 5 9b 9 24QV 97 5 24CiV i8ttarrta lower Consurrs inran # ¢ 2 < 4 ADDITIONAL U S , SupFrorted s atone ataon lnteda s 85485, RS232 Ethernet, 2ig8ee (optional) . � rs Revenue Grade Data A iSI 0121Optionalr ) ........ , .. . ........ ..t �,.... , . - .... . „ ....... , .., . d Shutdown NEC 2€114 690,12 { Yes �.,,�!pa, ., STANOAR01COMPLIAKE Safety .. . :... ,, ., tJL174i Ut9ta998 LJt1938 CSA Z22 ,�.... 1 Grid Connection Standards IEEE1547 Erratssioe�s FCC partlS class 8 F S AILLAT ON SPECIFICATIONS C oeatput rondust stza / A4sl rose 3/4 msnnmu rt 16 5 AWG 314'" minimum/ 8 3 AWG „ „_.,.., .. 1.... ,,.— D input conduit size # of strings 314" minimum j 1-3 strings 3/4" minimum j 1-2 strings j 16-6 AW Dimensions with Safety Switch 30.5 x 12,5 x 10.5 J in/ 775 x 9xvRrxii 7 1 75 x„3i5 x 260 torn e e€ to with safer . t..., ..:.. 54,7 247.. �satul f 11.1kA .„,. . .. convection t Coohng Natural Convection and internal j Fans (user repla€ eabie) fan (user ...... .., reptacp blp noise e 25 517 d8A „ .._, _.,..... iv4tn.-Iliax. Operating temperature 13 to *1403 / -25 to a60 (-40 to +60 version dvabbleW) „F 1'C .... . ........ Protectson �taCin r . �rviA 3R €zt For either regiaaai se"Ingx please contact sa#atEd” upport, . • d$�r . , txp r A higher eurrent amens may be stead, the h vetter wM Rrnit gar ine curmot to the vahms states!, tasR nue grade Wers.er PIN: 5£ -US NR2 lrtrr3 W rter;5876 -U 2NNRii.: ak-4overso rmSExxxxA-U NU4(for763nvertenSE7 AU 7NNm). (I'v"hellat SE300OA-US SE380OA-US / SE500OA-US / SE600OA-US SE760OA-US SE1000OA-US / SE1140OA-US U4A -GERMANY - 17ALY-FRANCE,- JAPAN -CHINA -AUSTRALIA- THE NETHERLANDS- UK - iSRAEL www.solaredge,us ze-5 Uffl-k • i Power Optimizer h Module Add-Onfor North America Rated Input DC Po ea ' .300 3501 400 4015 ...... .... . .. �. ,. ,..._�... ..... ..,..ea, ...... ...... . W ..... Absolute Maximum input Voltage SRR 6 125 Vdc (Voc atlowresttemperature) .... ....... ........ �,.. 950/2,1 MPPT Operating Range9 - 4R 8-60 R ,. 80 12 5 - 105 Vdc �... ..,..., �..- . Maximum Short Circuit Current (isc) 10 Adc Maximum DC. Input Current 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency.... ...... 9g,6 e„ .....,�..,.... ..._...�.. ...... ........ ... ,.. ... C3e�eruoltage1-1­11-111-1Cat..� Category ll 0-100 ..-. ..., OUTPUT DURING OPERA I (POWER Tf H CONNECTED OPERATINGt ..r....,..:..., Y ... .. ... .. .....,. .... .., t4axsnaur Output Current 15 Adc Maximum Output Voltage 60 35 Vdc OUTPUTU N STANDBY TI DISCONNECTED FROM N INVERTER OFF).....; . Safety Output Voltaee Der Paver C otimizer ! 1 Vdc ECIC ECC: Paart15 Class 6, iEC61CX)0.6-2, IEC61000-6- Safet 9EC621,091-1 (class It safety),�UC1741 _ .. RoHS yes Maximum Allowed System Voltage ........ . 1,000 .. ............ ....... Dimensions(WxLxEi) 241x212x40.55.55x8.34x1.59 Weight (including cables) 950/2,1 input Connector MC4 / Amphenof / Tyco Output Wire Type / Connector double insulated; Arnphenol Output Wire Length Oi 5 3,0 1.2/3.9 Operating Temperature Range -40,•+85/40-+185 Protections Rating iP65 / NEI A4 Relative Hurnidity 0-100 ..-. ..., SIb txxte of up to 5%powe€tatePw6it' -_ . . ., . .>.... Rated 5TC:. powee of'the mod€at vf divlow ed. .. ... .. .....,. .... .., Minimum String Length ICI (Power Optimizers) Maximum String Length25 25 (Power Optimizers) ... .... Maximum Power per String 5250 6000 Parallel Strings of different lengths Yes or Orientations ft is not allowed to Mot P405 with P300jP,350jP400/u /PAr) to one, string, 50 75T Wheat . WM r trw Y r x rpt Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel Flashing Material Finish • Char and black anodized aluminum • Mill Finish on select components Installation . Quick and efficient mounting * Adjustable hardware to ensure clean and level finish • All components bonded to ground with integrated bonding fea Calcs. & Certifications * UI_ 2703 Certification - circ of . Stamped Structural Engineering Reports for all 50 States/rolk- Grounding Grounding �P �I III I IIV MQ � i • r r • r . i k rack - PV M.. .r ,iii, -an ems (877) 732-2860 www.SnapNrack.com 0 Printed On recyc;ed Rater using soy ba ed rnks, e) 2014 by Sna{ay1rark FIV Mounting System, AR rights reserved, The SnapNrack line of solar mounting systems is designed to reduce total installation coasts. The system features technical innovations proven on more than of solar projects to simplify the installation and reduce costs. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is listed to the UL 2703 Standard for Bonding, meaning that all system components have been certified by UL for electrical continuity, eliminating the need for additional grounding hardware. The System's components provide an adequate bonding path which has eliminated the need for grounding lags and washers at each module, and bonding jumpers between splices. The UL 2703 Certification ensures that SnapNrack partners can provide the best in class installations in quality, safety, and efficiency. « All bonding hardware is fully integrated into the components • No grounding lues required for modules • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required LISTED PV Mounting System2703 sunrun, #low Job Number: SOIR-626MAYN; Plan Set: Rev A.2, Dated 11/11/16 Client: Melanie Mayner address. From the field observation, the existing roof structure was Observed as Composition Shingle roofing over roof plywood supported by 2x6 Rafter @ 24" OC. The roof is sloped at approximately 18 degrees and has a max rafter span of 7'10" between supports. M20MMUM 2015 International Building Code Basic Wind Speed Vult = 129 mph (Vasd = 100 mph), Exposure Y Ground Snow Load = 30 psf solar panel layout has been determined to meet or exceed the requirements based on our structural capacity calculations in accordance with applicable building c8dovw"T erieJO-re';4tar BE= . AM Civil Engineer Sunrun, Inc 11 1p�l I 1 1 HEMEW Exp. 10-31-2017 Im 1111111111111���11112:lii�ll�lI Structural Calculaflons for the Melanie Movirier Re,sidence PV Installation Date: 11/10/2016 Job Address: 2626 Gray St Wheat Ridge, CO, 80214 Job Number: 501R-626MAYN Scone of Work These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Desc[!pjjqa 2 Structural Geometry, Live Load, Snow Load, Wind Load, & Dead Load 3 Roof (1) Framing Check 4 Roof Attachment Check, Seismic Check, & Scope of Workk En ineerin Calculatians Surma Code: 2015 International Building Code ASCE 7-10 Live Load: LL = 20 psf Wind: Wind Speed Ult. (V) = 129 mph Exp. B UTAIM-5111, # - 0 MZ= Sage Lopez, P3 Civil Engineer Sunrun,lnc DP V = 3.0 psf 'ZO Irvine, CA 92618 1 P 949.383.091 133 1 city Or Structrure C;eomt Mean Roof Height, hn 11 ft Eave Height, he 8 ft Buiding length, L _ 43 ft Building Width, B w 40 ft Module Area - 20 f:2 Roof batch, 0 18 degrees Live load: Roof live load, Lr = 20.00 psf Equation 4.8-1 Snow, load. Ground Snow load, pg - 30 psf Fig. 7-1 Snow Importance Factor, Is = 1 Table 1.5-1 Thermal Factor, Ct - 1.20 'Table 7-3 Exposure Factor, Ce - 0.90 Table 7-2 Roof Slope Factor, Cs - 0.95 Figure 7-2c Fiat Snow load, Pf - Sloped Roof Equation 7.3-1 Sloped Roof Snow loads, Ps 30.00 psf Equation 7.4-1 is the width of the roof S Oft? Yes Drift Height, hd 5.44 ft Figure 7-9 Roof slope for a rase of one, S 3.08 Unbalanced Width - 6.71 ft Fig 7-5 V 17.90 pcf Equation .7-1 Unbalanced Snow load - 44.65 psf Fig 7-5 Wand load: Basic Wand Speed (3s -gust), V - 129.0 mph Figure 26.5-1A Building Occupancy Category 2 Table 1,-1 Exposure Category - B Sec 26.7.3 Topographic Factor, KzT 1:00 Equation 26.8-1 Adjustment Factor, it - 1.00 Figure 30.5-1 Edge Zone, a - 3.20 ft Figure 30.5-1 u lift O.6WZone 1(psf) Zone 2 (psf) Zone 3 (psf) Pnet3O _ «26.60 -43.94 66.01 Figure 30.51 Pt - 0.6 x h x KzT x Pnet3ol - -15:96 „26.36 -39.61 Equation 30.5-1 Rownward O.6W Zone 1(psf) Zone 2 (psf) Zane 3 (psf) New 15.76 15.76 15.76 Figure 30.5-1 Pnet - 0.6 x A x KzT x Pnet3o - 9.60 9.60 9,60 Equation 30.5-1 Read load: MO 1 Roof Walls - Exterior Composition Shingle 3.0 psf Wood 5,O psf 5/8 OSB Sheathing 2.0 2X4 Studs @ 16" 2.O 2x6 Rafter @ 24" OC 1.0 Gypsum 3.0 Mise. (Ceiling, Insulation, etc.) 1.0 Misc. (insulation, etc.) 2.0 PV System, Ppv 10 Total Roof Rl 10.0 psf Total Wall Rl. 12.0psf 133 Technology Dr., Suite 100, Irvine, CA 92618 P 949.393.0993 ZrAIMEMM Roof raming Check: Roof Framing = 2X6 Rafter @ 24" OC Timber Species = Doug Far -Larch fit- Max Beam Span - 7.83 ft b 1.501 in 5.50 in Moment of Inertia, Ix - 20.80 in Section Modulus, Sx 7.56 ani Bending Stress, Fb 900 psi Elastic Modulus, Emin 58psi Cas (wand) Co (Snow) Cas, Cir Ct Wood Adjustment Factors: 1;6t1 1«15 1.00 1.00 1.00 CL Cr OU Ca Cr LUt} 1.3 1.00 1.tN3 2.15 PV Tributary width, wpv = 2.75 ft PV Tributary Length, Lpv = 440 ft PV Tributary Area, At = 11,00 ft, PV Dead Point Load, Pe = Ppv x At = 31 Ib Roof Distributed Load, wDL = 13 plf Load Case; 0.6DL+0.6W fCID = 2.61 Roof zonae _ 1 Pup = Net x At + 0.6 x Pis it cos(0) = 157 lb Mb(wk4_Up) _ 247 lb -ft Fb' (wind) = Fb XCD XCLs XCM XCt XCL XCr XCsu XC+xCr = 2153 psi MaS%wabie = Sx X Fax` (wind) = 1357 Ib -ft > 247 DR Load Case: DL + QXW 1.6 Pdown = Pnet x At + PD x cos(G) = 137 Ib Mb(w nd_ n) = 373 lb -ft Fb` (wired) = Fb XCD XCLs XCM XCt XCL XCr XCnu XC« XCr = 2153 psi allowable = Sx X Fa,' (wind) = 1357 Ib -ft > 373 OK Load Case: DL + 0.75 O 6W1 + O 75S [ =1.61 Roof Snow Distributed Load, wSL = 60 pif Psnow = Ps X At = 314 Ib Mb(wind_snow) = 778 Ib -ft Fb' (wind) = Fb XCD XCrs XCM XCt XCL XCF XCs, XG XCr = 2153 psi Mallowabae a Sx x Fb' (snow) _ 1357 Ib -ft > 77$ Load Case, DL + S CD =1.15),`� Roof Snow Distributed Load, wSL 60 pifPsnow : Ps X At _ 314 lbMtt(snow) _ 774 lb -ft e11,PFb' (snow) Fb XCD XCs XCM XCt XCL XCr XCfU X0XC€ - 1547 psi Mallowab#e = Sx x Fb' (snow) = 975 Ib -ft > 774 "QX_ 133 Technology lir,, Suite 100, Irvine, CA 92618 P 949.393.099 sunrun Engineer: Sia Date: 11/10/2016 Job: 501R-626MAYN Address: 2626 Gray St Wheat Ridge, CO, 80214 4 of 4 Puoft = At x Pnet(2) 290 lb 5/16" Lag Screw Withdrawl Value 266 On Table 11.2A - Nos Lag Screw Penetration 2,5 in Allowable Capacity with Co 1064 lb > 290 OK 5eecle. Existing Dead Load: Solar Dead Load: ArooNxisting = 1720 ftp �Wpsnei = 42 Ib wro*feAsting = 12040 lb Numpanei = 14 Awaitexisting = 1328 ft2 wpenei-tot = 588 lb wwau"Wnii = 15936 lb woos = 1371b . ..... ..... MOW = 27976 lb wa"ay = 725 Ib %increase= twtotai+warmY)/ wtow y 28701 *100%-100% 2.59% --T7-976 "The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Sco e of Work and Liaallt MIMBUXAMOM 1 01 , Mimlifii sat .4 procedures, 133 Technology Dr., Suite 100, Irvine, CA 92618 1 P 949.3910993 I ANS It, 1; 61�Z I A\ \\ ��\\\ I v of , VVI')ez't Ridge ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRE TYPE FRAME MAXFRAME OC ROOF EDGE MAXRAIL MAXRAIL DESIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR -81 COMP SHINGLE FLASHED L FOOT, SEE PEN D81. SINGLE STORY ATTIC WOOD RAFTER 2X6 5° - 8" 4" N/A 4" - 8" 2' 1" REC SOLAR. REC275TP AR -82 COMP SHINGLE FLASHED L FOOT. SEE PEN D81. SINGLE STORY ATTIC WOOD RAFTER 2X6 T- 18" 24" N/A 4'- 8" Z _ 1d"MODULE DIMS: 65»5" x 39!x i.5' AR -83 COMP SHINGLE FLASHED L FOOT. SEE PEN D81, SINGLE STORY ATTIC WOOD RAFTER 2 }G 6 T- 18" 24" N/A 4' 8" z - 1" MODULE CLAMPS: Portrait. 8.2" • 16.4°" D1 - AR -01 - SCALE: 1/8" V -it"," Lands e. 4.9'- E8 .8 PITCH: 18" MAX DISTRIBUTED LOAD. 3 PSF AZJ . 188° 11° 3" SNOW LOAD: 38 PSF —kWIND SPEED. -7 77-71 $ 129 MPH 3 -SEC GUST, 3` LAG SCREWS: 5116'x4,8": 2." MIN EMBEDMENT NOTE (E) SATELLITE DISH TO INSTALLERS TO VERIFY RAFTER z. BE RELOCATED SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E,O.R. OF 4' ANY DISCREPANCIES BEFORE PROCEEDING. PENETRATION SPACING: 11 ' FULLY STAGGERED �X +j fydP D2 - AR -0 - SCALE. 118" 1.-0" PITCH. 18° A I . 58" ,-13'-2"-,,-3'- t 134.2" -3'_t T sunrun ... 3 14# P t •..e` 0 ELECTRICAL CONTRACTOR a m..� .., ..,.�6040 wWsr 91sr ,avErsuE., WESTWNSTER, co 80031 xlPHONE 309 S77.C527 ,. ........�„ _ FAX 303 577.29 6"_7"" CUSTOMER RESIDENCE: MELANIE MAYNER 2625 GRAY ST, WHEAT RIDGE, 13 - Alt -03 - SCALE. 118" 11.00# � CO, 88214 PITCH; 18° Cify o IMx 278$ TEL, (303) 433r� �Pry . 3s-2-cao- � Wheat PROJECT NUMBER: 581 R-626MAYN t t tr tr s 3'�� 818.73$.2378 DESIGNER. w ROBERT BUSTAMANTE 4" *,.Y DRAFTER: .... o.... _� .. . DIMENSION I m. SHEET 4 LAYOUT REV: A.2 1111112816 Exp. 10-31-2017 PAGE PV -3.0 4 1201240 VAC yi M OPEN * j Y 3v SYSTEM SINGLE PHASE SYSTEM OPERATING VOLTAGE SERVICE OPTIMIZER y a x Ylr IS BLADE TYPE DEDICATED METER #: (N) SUN RUN RI rt XCEL G921030 UTILITY CENTRCON 4G 'ACIJISCONNECT GRID AC DISCONNECT METER a: 31. V 4 SUPPLY SIDE TAP 3 o EXISTING 125A � IN BREAKER �. EXISTING 240V METER SQUARE D 250V METER SQUARE 10 SQUAR I" FACILITY * ` PANEL LOADS enr_0"Y 4 AI. SYSTEM SIZE yi M OPEN * j Y 3v SYSTEM (N) LOCKABLE SYSTEM OPERATING VOLTAGE 350 V OPTIMIZER y a x Ylr IS BLADE TYPE DEDICATED (N) LOCKABLE (N) SUN RUN RI rt PV BLADE TYPE CENTRCON 4G 'ACIJISCONNECT N METER AC DISCONNECT METER a: 31. V 4 4 3 o a A #. � 20A FUSE 240V METER SQUARE D 250V METER SQUARE 10 SQUAR SOCKET DU221RB SOCKET D2 2N8 200A CONTINUOUS 3R, 0A,2P 125A CONTINUOUS3R, 60A 00VAC WITH LEVER 1 0/240VAC BYPASS 10'[MAX 10' FROM UTILITY METER) 240V METER FROM UTILITY (READILYACCESSIBLE MEANS 200A, FORM 2S METER) FOR RAPID SMUT DOWN) WITH FACTORY INSTALLED RAPID JUNCTION BOX PV MODULES R EQUIVALENT REC SOLAR: REC275TP 1 (14) MODULES � OPTIMIZERS UVIRPI3 IN (1) SERIES OF (14) OPTIMIZERS NOTES TO INSTALLER. 1, 14 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE, 2, CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN BREAKER IN FAIN PANEL. ENCLOSURE. CONDUCTORS ARE FIELD INSTALLED, MODULE CHARACTERISTICS V, AI. SYSTEM SIZE yi M OPEN * j Y 3v SYSTEM 14 V SYSTEM OPERATING VOLTAGE 350 V OPTIMIZER y a x Ylr IS 500 V *EC ♦. y! SOLAR:INPUT 275 W ��IIIIIu�I�OIIR LTAGE MIN VUT O RI rt '. CODE: .. Il ! 1R EN itlr VOLTAGE R j 1k !. jGE j •`` al1� 1yI yy j MOF * j a: 31. V i ♦UTISCGE !Y l! ► CIRCUIT CURRENT SHORT a A #. YF• E M j OUTPUT CURRENT j YY SYSTEM CHARACTERISTICS � INVERT AI. SYSTEM SIZE yi M OPEN * j Y 3v SYSTEM 14 V SYSTEM OPERATING VOLTAGE 350 V O j rR MAX ALLOWABLE 500 V M Y p; YM M SYSTEM OPERATING } SYSTEM SHORT '. CODE: .. Wheat Ridge TABLE OF CONTENTS SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS PAGE # DESCRIPTION OVER SHEET SYSTEM SIZE: 3850W DC, 800W AC . ALL RK SHALL COMPLY WITH 2014 NEC, 2015 IBC, MUNICIPAL CODE, AND SE SERVICE ENTRANCE SOLAR MODULES 'V 1. MODULES: (1 4) REC SOLAR: REC275TP ALL MANUFACTURERS" LISTINGS AND INSTALLATION INSTRUCTIONS, RAIL PV 2.0 SITE PLAN NV T R * PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC, (1) ) REDGE TECHNOLOGIES SE3800 (240V) W/ -ER-US . ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC, MF' MAIN PANEL PV -3.0 LAYOUT OR A -US • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV -4.0 ELECTRICAL RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. PV_5.0 SIGNAGE SES PEN D01. » MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. P SUB -PANEL STANDOFFS INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. FOOTINGS RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 I PV LOAD CENTER CHIMNEY IFC 505.11.2.° • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.4 AMPS MODULE SHORT CIRCUIT CURRENT, SM SUNRUN METER ATTIC VENT 14,68 AMPS DERATED SHORT CIRCUIT CURRENT (690.6 () & 690.8 (b)). FLUSH ATTIC VENT PM DEDICATED PV METER IT PVC RIPE VENT INVERTER(S) WITH 6,01 METAL PIPE VENT" INV INTEGRATED DC city of DISCONNECT AND AFCI 0 T -VENT AC AC DISCONNECT(S) ED I IIDivision ENT SATELLITE DISH �V ons DC DC DISCONNECT(S) FIRE SETBACKS 4 Irrar CB Dote COMBINER BOXHARDSCAPE .....° F __l INTERIOR EQUIPMENT" PL-- PROPERTY LINE specificatk-4unot LE a SHOWN AS DASHED SCALE: NTS sunrun Of t _ Cts giveA AMPERE authodty tai vK90te ° or other ad, . of the City Shoff not be lid, AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER IM AZIMUTH ELECTRICAL CONTRACTOR COMP COMPOSITION 6040 REST 91 ST AVENUE, WESTMINSTE:R, CO $0031 VICINITY MAP30 DC DIRECT CURRENT PHONE3057796.$621 ., „, . (E) EXISTING EXT EXTERIOR FRM FRAMING CUSTOMER RESIDENCE: MELANIE MAYNER INT INTERIOR LBW LOAD BEARING WALL 2626 GRAY ST, EAT RIDGE, CTIDCO, 80214 '<'. MAG MAGNETIC MSP MAIN SERVICE PANEL TEL (303) 433-8641APN k 39-254-00-008 (N) NEW PROJECT NUMBER: NTS NOT TO SCALE ° 5018-626MAYN OC ON CENTER PRE -FAB PRE -FABRICATED 818338,2318 818.738.2318 PSF POUNDS PER SQUARE FOOT, , DESIGNER: 'gr >°,w ROBERT BUSTAMATE PV PHOTOVOLTAIC "`"�7a�� TL TRANSFORMERLESS / DRAFTER: Denv TYP TYPICAL a V VOLTS DIMENSION 1 W WA SHEET REV NAME DATE COMMENTS COVER SHEET Al R.BUSTAMANT 11/11/2016 PE REVIEW CHANGES REV: A.2 11/11/2016 �_ : PAGE • 0 w BOLT All SPLIT WASHER Iwl:�arirT+yi"*�i"J r • r .1, il` RAILS CAN BE LEVELED UP TO 3' USING UP TO TWO LEVELING SPACERS AS SHOWN IN 'SERIES 100 RAIL. LEVELING' G. GMcPHEE7ERS SCALE DNS PART . McPHEETERS GATE 1 C}I11 P DO1 REVISION: NOTES, 5/16' LAG BOLTS MUST EMBED 2>5' INTO ROOF STRUCTURAL MEMBERS/'RAFTERS - TORQUE ALL 5/16' HARDWARE TO THE FOLLOWING, - SILVER S.& ITI-IES FT -LBS - BLACK &S. 7-9 FT --LBS - RAILS CAN MOUNT TO EITHER SIVE OF L FOOT CUPSLOPE VSDOWNSLOPE) STEP 3f PLACE L FOOT ON TOP OF FLASHING AND TIGHTEN NUT STEP P1 SLIP FLASHING OVER L FOOT BASE STEP It BOLT L FOOT BASE TO ROOF WITH LAC BOLT •MN t no 14 C a ~t z > a ~O 5 ~ L i ° ` o W y CJ o o i o a y n Paz m s ' m ° ' ~rQ e'ap ~ Z ti aCZ v ~ o . (j ~ ~L} m p m y ti mns^ ° G °"an a.:y io D v °nPD y m m m D ^*~a 4 y c-i m mao z q` D. y O N a F Z z a x Y y9 . ❑ t'+. 0 , v o M a o m 4! Dno m n y a 2 y O y M m z x O 02 c ❑ ~ . .r- mm r3 . k . r ~ 9 O I a m n m Mon A a CD9 I zm m ❑ c aam h ~ ` ~ 9 C NWZ a z 3 y ]1 p 3 m - ° o .y 4 om-n ~.3 z M a M mm= n o . S3 m T O D y ~ ' O ~ ~ 1 mx . 'tib _ 9min ~ O mc Dm j 6 z ' ~ ~ f~+y ' F j °a o s 9 U 2 E y y 3 _ Z a~z H pp' r mac g m>z o o•,- m ~o x y n m n x Sa•• ti m:. < a a a yv Z y O 0 v z 2 r O D O T y & 09 pyT z o n T T 9 Z ' O T `o A O x n m r m z LO DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number: Date: 13046 11/2/01 Property Owner: Property Address: 2626 GRAY ST Contractor License No. : Company: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone: 433-8646 Phone: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown, and allegations made are accurate; that] have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable heat Ridge ordi es, for work under this permit. (OWNER)(CONTRACTOR) SIGN ATE~ Total: $200.00 $23.50 $0.00 $5.00 $28.50 Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description: (1) 6' FENCE APPROX 22' IN LENTH RUNNING NORTH TO SOUTH ON T~E N SIDE OF PROPERTY. ...;" "6\;)') \( BUILDING DEPARTMENT USE ONLY ____I. SIC: Sq. Ft.: Approval: MP Pleue Note: Zoning: R-1C Owner I contractor is responsible for locating property IIIlIIIIIIIIIIiII lines and constructing improvements according to the 11/1/01 approved plan and required development standards. Approval: BG The City is not responsible for inaccurate infonnatioll ~1iII submitted within the plan set and any construction 1 . H ., errors resulting from inaccurate infonnation. Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shalt expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired fOf a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty.four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. The' . u n~it or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the sio /11 ~g codes or any other ordinance, law, rule or regulation. , (4) (5) (6) DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) APPLICATION Building Permit Number: Date: G Property Owner: ('\\ ~\CtJ\\'t_ \\\Ch.f nE-( Property Address: ?-ts>~19 (!, (~ ~. W\.cu.t'R.....~ Contractor License No.: Company: Phone: 303Y33-8"Io<'\(o Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Construction Value: ZoO""" Permit Fee: Plan Review Fee: Use Tax: Total: (OWNER)(CONTRACTOR), SIGNED DATE (DeSCriPtion:(\1 10' V't.nc-S U.??ro,l. ?,-;).l 11'\ \'d1~ (Unf\ll'\q f'OCt-l--toSOut"1-l 00 '- \r-. E--~r. s...:.ck- O-t- ~fO~utj BUILDING COMMENTS: .1. J Approval: 1111101 ~, r;. BUILDING DEPARTMENT USE ONLY ZONING COMMENTS: AD Approval: JVf Zoning: R-1C PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City, (2) This permit shall expire if (A) the work authorized is Dot commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractorshall notify the Building Inspectortwenty-four(24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance. taw, rule or regulation. ~! ,j, 1€:'~~ Chief Building In cto City of Wheat Ridge Building Department 7500W.29th,be. Wheat Ridge, CO 8021 5 (303) 235-2855 Bob- (303) 235-2850 Darin- (303) 235-2853 It has been brought to our attention that the property at 6 '-t may be in need o~;;~~;owin;~3 ,j-. )1-rence or wall permit D I!oofing or Siding permit D Deck permit D Sprinkler permit D Shed permit D Sign permit D Driveway or walk- way permit D D ncavation permit. D ~~Il' \~ '60 --tut~ ~ Jl\ud. ~~~J.rot.-~ ~~ lo} ~.JWU-O{ ~ Please call rr stop by City Nail w~t~in 7 days for information. 00' lnQ., Thank you. ~ ~C'\XJ~~0U:t~~ ~. D Demolition permit D Interior/rxterior I!emodel permit D rJetached/Attached (iarage permit D Addition to residence permit a. . l.i/r:;..ICI( . Date City of Wheat IIldge Building Inspector -;Z \)J.L (ifS \y\OJ \ v--q t \. S S"f..\ ':::;\\ n~ \<cnc.'<'.- \,;,~ bCLC.-L(J:ust ') ~~(o)(. 19 i e In'S1o...U\nq rI'e..Lu wood \''Cnc1nq wd~ ~o.t-'2- ' t ~ \\~y . . G- ("Au H" ~ \)R\'JC-Wy>.~ Gt\R\\0'i/ I\\;'-" , , , ~\:"<;L - " - ,!)~' ~OC'R. <.----~. , '<C'/-'';,'\\f\)c,.. rct0cl:- ~ ~~ f<-"'V ~~ \\Ot)s~ ~~d-lD G (CLI.-\ 'St w\r\w~ S5 OJ. \ '-\ \~c.i)\ '\~~~ W Vj EXHIBIT A A TRACT OF LAND DESCRIBED AS BEGINNING AT A POINT 25 FEET EAST AND 284.5 FEE1 NORTH OF SOUTHWEST CORNER OF THE EAST ONE-HALF OF THE WEST ONE-HALF OF THE SOUTHWEST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 25, TOWNSHIP 3 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, COUNTY OF JEFFERSON, STATE OF COLORADO; THENCE EAST 75 FEET; THENCE NORTH 5 FEET; THENCE EAST 75 FEET; THE~ NORTH 45 FEET; THENCE WEST 150 FEET; THENCE SOOTH 50 FEET TO THE POINT OF BEGINNING, COUNTY OF JEFFERSON, STATE OF COLORADO. J FACILITY LOCATION SKETCH UTILIQ1~;'~!'S"'",ion, :: I', j", 1.,. i ' ~ 1"\ :t' -i i l I,j' r i .f.; ri.' '\.,-' r" "~I i.' "! " '! [: How Marked: 0 Paint 0 Flags 0 Nylon Whiskers Print# Time Arrived Time Completed N * LOCATOR INDICATE NORTH o DIG ALERT C' Major facility In or near dig area. Please hand dig and expose all facilities or call Utlliquest for assIstance! " l.."_.,~____._.._.,<.' o Watch & Protectl Standby Required o Copy left at site Sketch left at: l'XCAVATOR NOTIFIED Name Dale:~Tlme_AM PM Log# FACILITY OWNER NOTIFIEO Name Oate:~Time:----,----AM PM THIS SKETCH IS APPROXIMATE: 1suicHE's'HORIZONTALLY FROM EXTERIOR SlOE OFTHE FACILITY IS CONSIOERED A CORRECT LOCATION: COMMENTS LOCATOR'S NAME DATE EXTENDED JDB AGREEMENT Our company and I agree that this original locate ticket is an extended job and that locates will be done on II day-la-day basis. No excavating will take place until Signed paperwork IS received by our Company with the dig area defined. Excavators Signature Signature of person on job site City of Wheat Ridge Building Department 7500 W. 29th ..be. Wheat Ridge, CO 80215 (303) 235-2855 Bob- (303) 235-2850 Darin- (303) 235-2853 It has been brought to our attention that the property at :-:Jl.cc'H {' b1.t2Lc" (Yf~ may be in need of the followin.r. 'li-f'ence or wall permit o Roofing or Siding permit o Deck permit o Sprinkler permit o Shed permit o Sign permit o Driveway or walk- way permit o ficavation permit o Demolition permit o Interior/rxterior Remodel permit o Detached/4ttached Oarage permit o 4ddition to residence permit o o Please call or stop by City nail within 7 days for information. Thank you. '15/1 , ? City of Wheat Ridge Building Inspector .:h~ Date ('3/ Z!N01 15: 07: 31f UNCC Page If WHTR01 00005 UNCC 03/29/01 03: 08 PM 0146423 NORMAL GRID Ticket Nbr: 0146423 Original Call Date: 03/29/01 Time: Requested For Date: 04/12/01 Time: State: CO County: JEFFERSON Addr: 2626 Street: GRAY ST Grids: 03S069W25SE Type of Work: FENCE Exp.: N Location: LOC ENTIRE LOT --ACCESS OPEN-- --PLS PAINT & FLAG- PLS LOC ON THURS APRIL 12TH AFTER 9AM MELONIE MAYNER HIO 02: 44 PM 08: 00 PM City: Op: JAL Hrs Notice: WHEAT RIOGE 245 Me e t: N Legal: C Company : Caller Done for: Rema rks: Phone: (303)433-8646 SELF Members: ATCTOl : ATDWOO : ATND06 : MCLD3D : PCNDOO : PSND06 :UONDOO : USND06 : WHTROl Members: WRSN01