Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3275 Harlan Street
i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address:,�- Permit Number: \ c) ❑ No one available for inspection: Time ''3 '-) AM/PM Re -Inspection required: Yes j,o When corrections have been made, schedule for re -inspection online at: http://www.ci. wheatridge. co. uslinspection Date:`- i i rte' \ i Inspector. �-- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office . (303) 237-8929 F'— INSPECTION NOTICE Inspection Type: Job Address: �► t- �!� r 1 ,, Permit Number:" ` 1 U ❑ No one available for inspection: Time �' } AM/PM Re -Inspection required: Yes (�Sq�� When corrections have been made, call for re -inspection at 303-234-5933 Date: Z Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: `' ` `'� �~ a Job Address: �r Permit Number: �....a. '. �t t.4:0 "-\ %. —'No one available for inspection: Time (__)";.0`J AM/PM Re -Inspection required: �Ie No When corrections have been made, call for re -inspection at 303 -234 - Date: <� '- 1 cp Inspector: DO NOT REMOVE THIS NOTICE - City of Wheat Ridge y E -Res. Window Replacement PERMIT - 201901552 PERMIT NO: 201901552 ISSUED: 07/29/2019 JOB ADDRESS: 3275 Harlan St EXPIRES: 07/28/2020 JOB DESCRIPTION: Replacement of 7 windows of U -factor of .27. *** CONTACTS *** OWNER (209)404-7659 FARBER KATHLEEN SUB (303)574-9594 RICK ROSE 080085 WINDOW WORLD OF DENVER *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 3,990.00 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 83.79 ** TOTAL ** 133.79 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applica le building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the legal owner of the property and am authorized to Obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed ithis document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any appl ble code or aq,' prdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dina Kemp �(D /SS-2- From: no-reply@ci.wheatridge.co.us Sent: Monday, July 29, 2019 1:49 PM To: CommDev Permits Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address 3275 Harlan Street Property Owner Name Kathi Farber Property Owner Phone 209-404-7659 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email N/A Address **REQUIRED** Attach WR Cc 3275. pdf Credit Card Authorization Form - **DO NOT ATTACH RANDOM DOCUMENTS" * CONTRACTOR INFORMATION Contractor Business Window World Name 1 Contractor's License 080085 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-574-9594 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address acaro@windowworldcolorado.com Retype Contractor Email acaro@windowworldcolorado.com Address DESCRIPTION OF WORK Number of window 7 Windows and/or doors being replaced Location of Front Room, back room, side of house and basement window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): What is the a -value of the .27 window(s)/door(s)? City of Wheat Ridge requires the u -value to be .32 or better on windows.. Attach copy of WR order 3275.pdf window/door cut sheets showing sizes and a -value Project Value (contract 3,990.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit 2 issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Tasha Engh Permit Email not displaying correctly? View it in your browser. i City of Wheat Ridge Residential Remodel PERMIT - 201900972 PERMIT NO: 201900972 ISSUED: 05/13/2019 JOB ADDRESS: 3275 Harlan St EXPIRES: 05/12/2020 JOB DESCRIPTION: Retil bathtub and floor; replace toilet and vanity; Replace fireplace insert using existing gas *** CONTACTS *** OWNER (303)237-0169 FARBER KATHLEEN SUB (303)816-4900 CHRIS GOODRICH 120265 GOODRICH CHIMNEY SERVICES *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,000.00 FEES Total Valuation 0.00 Use Tax 126.00 Permit Fee 140.90 ** TOTAL ** 266.90 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this permit. I further attest that I am leggall authorized to include all entities named within this document as parties to the work to be performgd nd t atJI work to be p rfo d is di closed in this document and/or its' accompanying approved plans and specifications. Signafu're of OWNER or CONTRACTOR (Circle one) Date d 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. Th ' ance or gra i g of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any a i le de or r in ce or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat I,dge COMMUNITY DEVELOPMENT Building & Inspection Services 7500 W. 291' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cD-ci.wheatridge.co.us FOR OFFICE USE ONLY Date: 13 Plan/Permit # II 1 � V► Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: -?9, ! 6 faj-% S* , ( Gu at po Property Owner Property Owner Em Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer E-mail: Contractor Name: City of Wheat Ridge License #: Phone: Phone: Contractor E-mail Address: For Plan Review Questions & Comments (please print): CONTACT NAME (please print): Phone: CONTACT EMAIL(p/ease print): Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. ❑COMMERCIAL �RFtESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. Sq. FULF BTUs r Gallons Amps Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify, that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWN % (CONTRACTOR) or (AUTHORIZED R PRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last n el: / DATE: Printed Name: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: " , i f City of Wheat i e COMMUNITY DEVELOPMENT Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owr Project Prope Project Type: Notariz�d signature of Applicant State of Colorado } County of J� ers c� } ss The fore oing instrument was acknowledged by me this � day of 20/9by L"A_- F AMARA D ODEAN NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20164015481 MY COMMISSION EXPIRES APRIL 22, 2020 My Commission Expires __�/_22J20,2c) Notary Public ?0170& 3 ;-'°? S- /1�r INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Occupancy/Type Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Aaaroval Of The Above Insnectinns Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Anoroval Of The Ahnve Insper•tinnc gh Ipections o 7 Date Inspector Initials Comments . VVe Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof ( t./ _ / g Final Window/Doors Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. For iow voltage permits - Hease be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather o City of Wheat Ridge Residential Roofing PERMIT - 201706304 PERMIT NO: 201706304 ISSUED: 08/18/2017 JOB ADDRESS: 3275 Harlan ST EXPIRES: 08/18/2018 JOB DESCRIPTION: Residential Re -roof to install OC Duration asphalt shingles - 25 sq *** CONTACTS *** OWNER (303)237-0169 JERMAN RONALD F SUB (303)514-0528 Joe Jundt 160022 Modern Roofing LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned -SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,100.00 FEES Total Valuation 0.00 Use Tax 212.10 Permit Fee 220.15 ** TOTAL ** 432.25 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (pzoject address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. i CITY OF WHEAT RIDGE _��9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L/ 0 7 r r Job Address: ':� a -7 :T - Permit Permit Number: _�9 0 1 -7 o G �l ❑ No one available for inspection: Time 1= O AM PM Re -Inspection required: Yes 0 When corrections have been made, call for re -inspection at 303-234-5933 Date:l kl!a Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L) 0 q - F r,, ) Job Address: -37D -7 S 0 c( )n „ S 4 - Permit Number: a D! 7 0 G-9 o L/ ecL_d 7l�o I rl ef- 'eye 4 e i ! rlS'C�,2i7 ❑ No one available for inspection: Time '�i = 16, A PM Re -Inspection required: 6 No When corrections have been made, call for re -inspection at 303-234-5933 Date: / i Inspector: Tt DO NOT REMOVE THIS NOTICE i CITYf�6F WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: '3 p-7 S-fi- Permit Number: 0 17 n 3 G Ll M LIZ A 6� n �►.l� rnGC i ❑ No one available for inspection: Time c AM49 Re -Inspection required: Yes L" When corrections have been made, call for re -inspection at 303-234-5933 Date: I i S Inspector: DO NOT REMOVE THIS NOTICE City of 6 t 1 +" Ccs . set tD LoPmtNr Permit # 201600302 7500 W. 29th Avenue ©ate; 06/15/2016 Wheat Fridge, Colorado 80033 Occupancy:. I 1 11, .! # Mir Type of FOR THE FOLLOWING PURPOSE Residential Remodel -Use R-2 �Ad 'llll �I 1N0i�2 rICC/2014 NEC te. ICC/2011 NEC Chief Building Official change shall - made prior • • a new Certificate of Occupancy from of Wheat Ridge FOR OFFICE USE ONLY Date: City of AAJ g c(")MMuNtly DEVEIopmrN-1, Paniip"M" Building & Inspection Services Division 7500 W. 2e Ave., Wheat Ridge, CO 80033 Office'. 303-235 -2855 * Fax: 303-237-8929 Inspection Line- 303-234-5933 Property Addrew . ..... 3.22 Li I- ) cl i), (please pfint), Address- Contractor - Phone: Complete all information on ROTH sides of this form Sq. FULF _� _ situ's --- Gallons FOR OFFICE, USE ONL City of Date., ,PlanlP It # N �,�.. Building & Inspection Services Division 7500 W. 29�t` Ave., Wheat Midge, CO 80033 'Plan Review Fee., Office: 303-235-2855 * Fax. 303-237-3929 .,.w . Inspection Line. 393-234-5933 Property Address: o it Pr verty Owner (Wease i)rint) A _T 1 Phone: • - -1111 IN Address: P17 i C TA P4 1A ArchitectlEngineer E-mail:W. Phone., Contractor: Contractors City Ucense #: oz Phone- + i lb Contractor E-mail Address- Sub ddre Sub Contractors: Electrical: Plumbing: Mechanical: W,k City License ## W,R. City License # Wei. City License # Other City Licensed Seib: Other City Licensed Sub, City License # City License Complete to all information on BOTH skies of this form r COMMERCIAL � Ilr • i STRUCTURE ELECTRICAL b y SERVICE AN M` k RESIDENTIALNEW STRUCTURE COMMERCIAL ROOFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL p iNII STRUCTURE • «.w shed, deck, RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc,) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ! SYSTEM/APPLIANCE REPAIR F • iMM o REPLACMENT '. /ELECTRICAL d. ! • Y REPAIR IF • Y R # NY A ,WT nt of material to e J , etc.) r � J,r Ing rick . A- {�. AIL f Sq. FtdLF Btu's Gallons ,Amps Squares other 1111 qi;j 1718 FRY ROAD, SMITE 133 HOUSTON, Tib 77084 1888 78 a 47S(PT # + 1800 326- 7S(L v Client File No: 588643 -GC P► &16-00428 REPORTFebruary TEXAS FIRM REGISTRATION # F-9190 Page 2 PT&CILWG FileNumber 96-00428 Client Insurance File Number: PT&CILWG was retained by Nationwide Insurance Company to Inspect the subject residence and ,tetermine the extent of structural damage as a result of a vehicle Impact, Additionally, it ww pre- ,tamaged condition, • • .: * til #1 • z * x * s as � � ;� , � � � r � r► � r ♦ r � � w � � w • s • • , * ew r• s s DOCUMENTS REVIEWED The following documents were reviewed and/or referenced as part of PT&CILWGs investigation, and/or contain Information pertinent to the discussion and conclusions presented herein: a Jefferson County Assessor's Office online property records, URL. http://J ff o,us/ats/spl sh.do. 2. Google Street View Images, LIRL: www.google.com 2012 International Building Code, Residential Code, and Existing Building Cade, 4, City of Wheat Midge 2012 International Residential Coda Amendments. e ACI 530 Building Code Requirements for Masonry Structures.. 6. ASCE 7-0 Minimum Design Loads for Buildings and Other Structures. Page PT&CILWG File Number: 16-00428 Client Insurance File Number: 8 • are available to you upone« and conclusions and to revise our opinions and conclusions If necessary and warranted by the discovery of d r o Thank w for allowing r provideyou questions or "'ter additional assistance, please call or emalL PT&CjLWG Forensic Consulting Services i Peer Review By: James Project Engineer/Consultant PT&CLWG w s�°,w+► w w w w w w w s w w w� w a � r� • w w w wwDESION • PARAMETERS GROUND w . w b, FLATAOOF w w w SHOW w $00W LOAD, IMPORTANCE ROOF SNOWw ON WIND DESIGN $HALL CONFORM SECTION OF THE SC AND TABLE w w w w w IGN PARAMETERS ARE AS FOLLOWS ' .LOAD � ww b"NO LOAD IMPORTANCE w WIND EXPOSURE CATEGORY• 0, INTERNAL PRESSURE COEFFICIENT -1-0,18 SEISMIC DESIGN $HALL CONFORM WITH SECTION 16 w R3oj,2(j) Of THE CITY Of \NNVAT wRIDGE OUILDINO CODE SEISMIC DESION PAREMETERS ARE AS FOLLOWS w w 0, MAPPED SPECTRAL RESPONSE ACCELERATIONS %�AjtW-RW,--TRAL RESPONSE ACCELERATION SHORT PERIODS (S4N) - DESIGN O w w PERIODS s •., BUILDING SEISMIC DESIGN CATEGORY - 8 SEISMIC LOAD IMPORTANCE FACTOR (10) - 14 SEISMIC RESPONSE RESPONSE MODIFICATION FACTOR (R) - 11 DEFLECTION AMPLIFICATION FACTOR (Cd) - 1,25 w w $HEAR w 14 KIPS ATTACHMENT Of COMPONENTS w w w � 3 � ►+w w w w w w w z w s w w ep�p -w w. ,d w• w w. «,w w .� .& ww TO A)$C *SPECIFICATIONS FORDESIGN, FABRICATIONAND ERECTION OF STEEL FOR BUILDINGS,STEEL STRUCTURAL MANUAV 2, ELEMENTS WERE DESIGNED USING LRFO APPROACH CONSTRUCTION 3, STRUCTURAL STEEI,�, ASTM A36 (Fyx36k*Q MINIMUM FOR ROLLED PLATE& CHANNELS, ANGLES, ... �rw AS NOTED ON DRAWINGS, RESIDENCEJERMAN 3275 Harlan St., Wheat wiY" PC D « Q " '� � � i D REPLACED � �� ., SOUTHt III WALL� aw � POU16N �iwwriwmr�i WINDOW. * N M * dM aM hµ imt RI I PROVIDE i 3 -INCH OFBEARING IN EXISTING WALL " EXTERIOR A. Yip y i X= L # Y R VIN EXISTING i A p. } 1, ALL DIMENSIONS ARE FIELD MEASURED AND APPROXIMATE UNLESS NOTED OTHERWISE (UNO). 2. TOP OF MAIN LEVEL FLOOR ASSUMMED TO BE 100'-0" R rMAN RESIDENCE 3275 Harlan IIS ..... <:»!#■<� y° & /�■�\:d°\�� y #al lot y< » %/#\% \»*w<,�: a y # ««,::!<# w<■ MMOMEMPIMal _ «<<1 < °:,» OR FULLY� 0 # y# OF JOIST y� Y 1001.04f i ww� atom ii 110 yy BRICK #i EACH a U(NdR4& CMU WALL OR (N�i4j CMU WALL. BETWEENNFORCEDIN JOIST BEARING 2 COURSES VISIBLE I -T E 4'v* BELOW TOP OF FOUNDATION WALL L ( - /8' DEER) R MAN RESIDENCE 3275 .rlan St., Wheat Ridge, uiu a IND �J FRAMING ,� &: - 41-11 .,, WINDOW SIL " F�9 V2 SECTION UE 4" = V-0" M Jird Black Construction 12279 Pennsylvania Street 'Thornton, CO 84241 CD: 343.452.8714 F: 343.454.4626 Client: Jerman, Ronald Cellular'. (720) 891-5144 Property: 3275 Harlan St Wheat Ridge, CO 80033 Operator: GPRRRY Estimator: Cleary Perry Cellular: (343) 949-5722 Position: Project Manager E-mail: perry jimblaekconstruct on Company: Jim Black Construction .com Business: 12279 Pennsylvania Street Thornton, CO 84241 Type of Estimate: Vehicle; Date Entered: 1/22/2416 [Date assigned: Price .List: C0DE8X__JAN 16 Labor Efficiency: ltestoration/Service/Remodet Estimate: JERMAN 16-4455ST'R This estimate outlines the reconstruction work to repair damages caused by a vehicle impact at the above address. In this scope, the line items detail the required work to brim the affected area back to a pre-lass condition, if in the course of work additional damages are discovered, repairs must be authorized by your insurance carrier before corrections can be made.. Thank you for choosing Jim Black Construction. Please call if you have any questions. Regards, Geary Perry Estitnator& Project Manager Jim Black Construction, Inc. (M) 343-949-5722 (0) 343-452-8714 gpeny@JimBlackConstruction. o n Jim Black Construction 12279 Pennsylvania Street V --'r, I" Thornton, CO 80241 Cf: 303.452.8710 F: 303.450.0626 Main level " �• ""' Kitchen Height: 8* 355.33 SF Walls 133.47 SF Ceiling D 488.81 SF Walls & Ceiling 108.96 SF Floor 12.11 Sig Flooring 44.00 LF Flour Perimeter 46.50 LF C;eil. Perimeter Missing Wall -foes to Floor 2' 6" '4 6` 8" Opens into LIVING -ROOM Subroom: Pantry (1) Height. ' 77.33 SFhails 5,73 SF Ceiling J31 83.06 SF Walls & Ceiling 5,73 SF Floor ,, a 0.64 SY Flooring 9.67 LF Floor Perimeter a_ 9,67 LF C"eil, Perimeter DESCRIPTIO CYry 1.. Plumber - per hour 10.00 RR 2, Drain/Vent line _ ABS pipe with fitting and hanger, 2" 18.00 LF 3. Angle stop valve 1.00 FA 4. Rough in plumbing - per fixture i .00 EA 5. Electrician - per hour 4.00 FIR 6, Aluminum window, picture/fixed 12-23 sf (2 pane w/thermal) 2.00 EA 7. Aluminum window - casement, 6-8 sf 4.00 EA 8. Dishwasher 1.00 EA 9. Range - drop in - High grade 1.00 EA 1.0. Refrigerator _ top freezer - 14 to 18 cf 1.00 EA 11. Garbage disposer 1.00 EA 12. Sink - double - Premium grade 1.00 EA 13. Sink faucet - Kitchen 1.00 EA 14. Hatt insulation - 12" - R38 - unlaced batt 139.20 SF 15. Two coat plaster over 112" gypsum core blueboard 508.48 SF 16. Custom cabinets - wall units - 42" tall 6.92 LF 17. Custom cabinets - wall units - 0" tall 3,50 LF 18, Custom cabinets - wall units - up to 241" tall 3.00 LF JERMAI __16-0055STR 2/29./2016 Page:2 Jim Black Construction 12279 Pennsylvania Street Thormon, CO 80241 0: 301452.8710 F: 301450.0626 DESCRIPTION CONTINUED - Kitchen QTV 19. Custom cabinets - base units 1150 LF 20. Add for prefinished crown molding - w/demil per LF 16.00 LF At top of cabinets 2L Cabinet knob or pull 18.00 EA 21 Countertop - flat laid plastic laminate 27.08 LF 23. Ceram ic/porcelain the 24.67 SF 24. Seal/prime then paint part of the walls and ceiling (2 coats) 48181 SF 25, Paint door or window opening - 2 coats (per side) 100 EA 26, Stain & finish door/window trim & jamb (per side) 1,00 EA 27, Stain & finish door slab only (per side) 100 EA 28, Paint wood shelving, 12% 24" width - I coat 2,17 LF 29. Carpet pad - per specs from independent pad analysis 139.20 SF 30. Carpet - per specs from independent carpet analysis 174.42 SF 31. Carpet cove (wall wrap) - 4" 48,17 LF u's M MMMM= 620.33 SF Walls 950.31 SF Walls& Ceiling 35.87 SY Flooring 8150 LF Ceil, Perimeter Missin2 Wall -Cares to Floor 21 6T* X 61 8" DESCRIPTION 32, Window drapery - hardware, - Detach & reset MEM 329,97 SF Ceiling 322.79 SF Floor 80.00 LF Floor Perimeter Opens into KITCHEN INDIM JERMAN-16-0055STR 2/29/2016 Page: 3 Jim Black Construction 12279 Pennsylvania Street Thornton, CO 80241 0: 301452,8710 F: 303A50M26 DESCRIPTION CONTINUED - Living Room CITY 33. Two coat plaster over 1/2" gypsum core blueboard 234,67 SF 34. R&R Doorjamb per LF - interior - hardwood - 4 9/16" 17,00 LF Doorway to kitchen. MR for repairs 35. Casing - Detach & reset 34.00 LF 36. Sand wood - interior 17,00 SF 37. Stain & finish casing 17.00 LF 38, Baseboard - Detach and reset 29,33 LF 39, Stain & finish door/window trim & jamb (per side) 1,00 EA 40. Stain & finish baseboard 134,03 LF 41. 'rexture drywall - smooth / skim coat 329,97 SF Above line item is included in order to skini stress cracks. We must get a smooth consistent finish with a drywall skim coat, and then texture and blend in order to have an acceptable uniform appearance that the insured will accept. This room has a ton of natural light, if this process is not followed, the drywall repair will not be acceptable. 42. Texture drywall - light hand texture 329,97 SF 43. Seal/prime then paint the walls and ceiling (2 coats) 1388.61 SF 44, Carpet pad - per specs from independent pad analysis 329.68 SF 45. Carpet - per specs from independent carpet analysis 438.83 SF DESCRIPTION Laundry Room 240.00 SF Walls 296,08 SF Walls& Ceiling 6.23 SY Flooring 30.00 LF Ceil. Perimeter 56.08 SF Ceiling 56.08 SF Floor 30.00 LF Floor Perimeter QTY JERMAN-,16-0055STR 2/29/2016 Page: 4 Jim Black Construction 12279 Pennsylvania Street , fV Thornton, CO 80241 0: 303.452.8710 F. 301450.0626 CONTINUED - Laundry Room DESCRIPTION QTY 46. Washing machine - Remove & reset 1.00 EA 47. Dryer - Remove & reset 1.00 EA 4& Laundry tub - Detach & reset I M EA 49, Cabinetry - upper (wall) units - Detach & reset 3,50 LF 50, Two coat plaster over 1/2" gypsum core blueboard 19.00 SF 51. Texture drywall - smooth / skim coat 222.12 SF Above line item is included in order to skim stress cracks. We must get a smooth consistent finish with a drywall skim coat, and then texture and blend in order to have an acceptable uniform appearance that the insured will accept. This room has a ton of natural light, if this process is not followed, the drywall repair will not be acceptable. 520 Texture drywall - light hand texture 22112 SF 53, Paint door or window opening - 2 coats (per side) 4.00 EA 54, Seal/prime then paint part of the walls (2 coats) 22112 SF 55, Carpet pad - per specs from independent pad analysis 56.52 SF 56. Carpet - per specs from independent carpet analysis 82,50 SF 57, Carpet cove (wall wrap) - 4" 0,001,F Coat 97,33 SF Walls 105,67 SF Walls & Ceiling 0,93 SY Flooring 1117 LF Ceil. Perimeter WIMM 8,33 SF Ceiling 8,33 SF Floor 1117 1,17 Floor Perimeter DESCRIPTION QTV 58. Carpet pad - per specs from independent pad analysis 8.33 SF 59, Carpet - per specs from independent carpet analysis 34,08 SF JERMAN-16-0055STR 2/219/2016 Page. 5 Black Construction ,12279 glli' aennsyFvarna Street NN II°�f�l 0°Iljll Thornton, CO 80241 F: 303,450,0626 CONTINUED - Coat DESCRIPTION QTY OO: Hallway Height: 8' 35333 SF Waits 57.5 SF Ceiling 01 -re ,µ: 4 1 OM SF Walls& CeilingWalls,57,25 SF Floor Stuc, a> 6.36 SY Flooring 44.17 LF Floor Perimeter 7 44.17 L l' C:eil. Perimeter DESCRIPTION QTV 4. Carpet pad - per specs from independent pad analysis _ 57,25 SF 61, Carpet - per specs from independent carpet analysis 85,00 SF Bed—2 Height: ' 370.67 SF Walls 133.00 SF Ceiling 503.67 SF Walls& Ceiling 1:33.00 SF Floor 14.78 SY Flooring 46.33 LF Floor Perimeter 46.33 LF C"eil, Perimeter ,t 11 Al 16-0055STR 2/29/2016 Page:6 1 D Jim Black Construction 1 12279 Pennsylvania Street Thornton, CO 80241 F: 303.450.0626 DESCRIPTION 62. Clean and deodorize carpet NOTES: Subroom.- C1st-2 (1) 104.00 SF Walls 113.00 SF Walls& Ceiling 1.00 SY Flooring 1100 LF Ceil. Perimeter Bed I E J 4" Yl- �1' 1-3' 6" .4 � J' 9"" 328.00 SF Walls 432.22 SF Walls& Ceiling 11.58 SY Flooring 41.00 LF Cei 1. Perimeter MMMM 9.00 SF Ceiling 9M SF Floor 13.00 LF Floor Perimeter Height: 8' 104.22 SF Ceiling 104.22 SF Floor 41,00 LF Floor Perimeter Subrown: Clst-1 (1) Height: 8' 104.00 SF Walls 9.00 SF Ceiling 113,00 SF Walls& Ceiling 9,00 SF Floor 1.00 SY Flooring 13.00 LF Floor Perimeter 1100 LF Cil, Perimeter DESCRIPTION QTY 63. Clean and deodorize carpet 104,22 SF JF; RMAN-16-0055STR. 2/29/2016 Page: 7 Jim Black Construction 12279 Pennsylvania Street Thornton, CO 80241 0: 3014518710 F: 303.450.0626 CONTINUED - Bed—1 DESCRIPTION NOTES: 23333 SF Walls 277.64 SF Walls& Ceiling 4.92 SY Flooring 29.1? LF Ceil. Perimeter QTY ME= 4431 SF Ceiling 44.31 SF Floor 29.17 LF Floor Perimeter DESCRIPTION QTY 64. Clean and deodorize carpet 41,19 SF M 354,67 SF Walls 475.00 SF Walls & Ceiling 13.37 SY Flooring 44,33 LF Ceil, Perimeter DESCRIPTION 65. Window drapery - hardware - Detach & reset J1 RM a 16-0055STR Height: 8' 12033 SF Ceiling 120.33 SF Floor 44.33 LF Floor Perimeter 2/29/2016 QTY 1,00 EA Page: 8 M 12279 Pennsylvania Street Thornton, CO 80241 0: 303.452.8710 F: 3014500626 CONTINUED - Study -Q,-Fy 66, Two coat plaster over 1/2" gypsum core blueboard 3100 ST 67, Detach & Reset Casing - 2 1/4" 34M LF Doorway to laundry & hallway R&R for repairs 68. Texture drywall - smooth / skim coat 177.33 SF Above line item is included in order to skim stress cracks. We must get a smooth consistent finish with a drywall skim coat, and then texture and blend in order to have an acceptable uniform appearance that the insured will accept. This room has a ton of natural light, if this process is not followed, the drywall repair will not be acceptable, 69. Texture drywall - light hand texture 177.33 SF 70. Stain & finish baseboard 39.00 LF 71. Stain & finish door/window trim &jamb (per side) 100 EA 72. Seal/prime then paint part of the walls and ceiling (2 coats) 436.17 SF 73. Carpet pad - per specs from independent pad analysis 12033 SF 74. Carpet - per specs from independent carpet analysis 153.42 SF Closet Height: 8' 134,67 SF Walls 16.25 SF Ceiling 150.92 SF Walls & Ceiling 16.25 SF Floor 1.81 SY Flooring 16,83 LF Floor Perimeter 16.83 LF Ceil, Perimeter DESCRIPTION QTY 75, Carpet pad - per specs from independent pad analysis 1625 SF 76. Carpet - per specs from independent carpet analysis 16,25 SF JERMAN__16-0055STR 2/29/2016 Page: 9 �u.3im Black Construction lThornton, CO 80241 F: 303.450,0626 - DESCRIPTION QT NOTES: Basement Stairs Height: 15' 6" 243.30 SF Walls 28.00 SF Ceiling 271,30 SF Walls & Ceiling 51.99 SF Floor 5.78 SY Flooring 2614 LF Floor Perimeter 21.67 LF' Ceil. Perimeter Sulrroorn: Stairsl (1) 52.00 SF Walls 62.56 SF Walls & Ceiling 1.17 SY Flooring 6.50 LF Ceil, Perimeter 10,56 SF Ceiling 10,56 SF Floor 6,50 LF Floor Perimeter Missing Wall YX 8' Opens into STAIRS Missing Wall X 4" 4 8f Opens into Exterior DESCRIPTION QT 77, Carpet pad -per specs from independent pad analysis 60.29 SF 78. Carpet - per specs from independent carpet analysis 86.00 SF 79. Step charge for "tacked" carpet installation a High grade: 13.00 EA ,1ERMAN__16-0055STR 2/29/2016 Page: 10 Jim Black Construction 12279 Pennsylvania Street Thornton, CO 80241 0: 101451 R71 A F: 301450,0626 CONTINUED - Stairs DESCRIPTION QTY NOTES: Bar 34933 ST Walls Bar 47146 SF Walls & Ceiling 1168 SY Flooring T X, 47,83 LF Ceil. Perimeter Missing Wall - Goes to Floor 5" X 6' 8°" DESCRIPTION 80, Stain & finish door/window trim & jamb (per side) 81, Stain & finish door slab only (per side) 81 Vinyl tile 83a Floor preparation for resilient flooring 84 1/27" - drywall per LF - up to Ttall 85, Cove base molding - rubber or vinyl, 4" high 86. Acoustic ceiling the 87. Seal/prime then paint part of the walls (2 coats) 88, Stain & finish baseboard 89. Stain & finish door/window trim &jamb - Large (per side) 90. Clean countertop NOTES: 123.13 SF Ceiling 123.13 SF Floor 42.83 LF Floor Perimeter MRSIM QTR" I ,00 EA 1.00 EA 12113 SF 123.13 SF 12.00 LF 12.00 LF 123,13 SF 308.72 SF 28,33 LF 1.00 EA 2(Y.00 SF JERNIAN--.16-0055STR 2/29/2016 Page: 11 Jim Blaen Construction 12279 Pennsylvania Street Thornton, CO 80241 C?. 303.452.8710 F: 303.450.0626 Lien C n Missing Wall - Goes to door Missing Wall -+does to Floor DESCRIPTION 91. Clean and deodorize carpet NOTES: 646.67 SF Walls 103108 SF W alls & Ceiling 42.82 SY flooring 86.67 LF Ceil. Perimeter 2#X6'8wf e X6'8f* 385A2 Sl~ Ceiling 385.42 SF floor 79.67 Ll~ Floor Perimeter Opens into Exterior Opens into BAR. Closet: Height: 165.33 SF Walls � 21.25 SF Ceiling 186.58 SF Walls & Ceiling 2125 SP Floor 2.36 SY Flooring 20.67 LP floor Perimeter 20.67 LF C"eil, Perimeter DESCRIPTION QTY 92, Vinyl file 21.25 S1• 93. Floor preparation for resilient flooring 21.25 SF 94. Cove base molding - rubber or vinyl, 4" high 18,17 LF NOTES: JP.itMAN 16-0055STR 2/29/2016 Page: 12 Jim Black Construction 12279 Pennsylvania Street Thomton, CO 80241 Tye, f"), A 'I in : J -,—.A ,01 F: 303,450.0626 Ll Ll Exterior Formula Elevation 0" x 0" x 0" Subroom 1: Front Elevation 170.67 SF Walls 170.67 SF Long Wall 21,33 LF Ceil. Perimeter Subroom 2: Left Elevation 104.00 SF Walls 104.00 SF Long Wall 13,00 LF Cell, Perimeter DESCRIPTION 95. Soffit - metal/vinyl - Detach & reset 96. Brick veneer - Detach & reset 97. Brick lintel - steel 98, Block - 4" x 8" x 16" - in place 99. Block - Add if vertical reinforcement is 24" OC 100. (Material Only) 4" x 4" square wood post (1.33 BF per LF) 101. Carpenter - General Framer - per hour Formula Elevation 21'4" x S'x 0" 21.33 LF Floor Perimeter 170.67 SF Short Wall Formula Elevation 13' x S'x 0'* 13,00 LF Floor Perimeter 104.00 SF Short Wall QTV 42,00 SF 32100 SF 10,67 LF 275,00 SF 275.00 SF 4&00 LF &00 HR JERMAN-16-0055STR 2/29/2016 Page: 13 Jim Black Construction 11 279 ennsylvama Street Thormon, CO 80241 0: 303,452.8710 F: 303.450.0626 DESCRIPTION 102, Electrician -per hour Trace out and isolate power to kitchen, downstairs bar and furnace. NOTES: Plumbing DESCRIPTION 103. Plumber - per hour Winterize NOTES: General Conditions DESCRIPTION 104. Megohmmeter check electrical circuits - average residence 105, Content Manipulation charge - per hour 106. Cleaning Technician - per hour 107, 'razes, insurance, permits & fees (Bid item) 108. Temporary toilet (per month) lK Furnace - check, clean, replace filters and service MDM ■ QTY I M EA 12.00 HR 8.00 HR 1.00 EA 6M MO 1.00 EA JERMAN 16-0055s,rR 2/29/2016 Page: 14 Jim Black Construction 12279 Pennsylvania Street < Thornton, CO 80241 0: 303.452.8720 .*. 303.450,06 26 DESCRIPTION RIPTIO CONTINUED - General Conditions Demo and Debris Removal DESCRIPTION QTV 110 Dum sten load - Approx 20,vards, 4 tans of debris 2.00 PA Construction debris, 111, Single axle dump truck - per load - including dump fees Masonry debris. 112. General Demolition - per hour NOTES: Attic DESCRIPTION QTV 113. Blown -in insulation - 12" depth _ R30 � 50,00 ST 114, Insulation Installer -per hour 6,00 tib JERMA;v 16-0055 STR 2?29/2016 Page: 15 Jim Black Construction 12279 Pennsylvania Street "Mormon, CO 80241 303,452,8710 F. 30' )A50.0626 DESCRIPTION NOTE'S: Labor Minimums Applied DESCRIPTION 115. Fleat, vent, & air cond. labor minimum Grand Total Areas: 5,666.96 SF Walls 1,818,00 SF Floor 274.67 SF Long Wall 1,818.00 Floor Area 2,535.17 Exterior Wall Area 0.00 Surface Area 0,00 Total Ridge Length CONTINUED - Attic 1,825,71 SF Ceiling 202,00 SY Flooring 274.67 SF Short Wall 1,993.43 Total Area 283,17 Exterior Perimeter of Walls 0,00 Number of Squares 0,00 Total Hip Length 7,492,67 SU Walls and Ceiling 704,24 LF Floor Perimeter 716,67 I,F Ceil, Perimeter 5,097.00 Interior Wall Area 0,00 Total Perimeter Length qry ■ JERMAN.-16-0055STR 2/29/2016 Page: 16 IM m oz x I Ef SR I r_.'.-.--'T'"!;7'-'-'~"-" H COMMUNITY DEVELOPMENT DEPARTMENT Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: ,e;/V,# Jc..z;r Job Address/Permit Number: '1;17$ 1+..4;,(1.4./ 07/:2,;'7 /t?t?; CuF,? o No one available for inspection: Time ;L :Vu AM/PM Re-Inspection required: Yes CNoJ .When corrections have been made, call for re-inspection at 303-234-5933 Date: /1 hI" '7 . Inspector: .?::.-~ DO NOT REMOVE THIS NOTICE COMMUNITY DEVELOPMENT DEPARTMENT Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office' (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: KA./# ;.JrnF Job Address/Permit Number: ]175 HA.#.A-/i/ ~ T. 07/ ~ 87 /'14/1.81/-,,/1 Nt- <</*/1/ W/f~~ ;JF,.!/I?lT) A <A-H -f I//<;A;::;l;: //V'J'".'77"~ . o No one available for inspection: Time 7:Y5 AM/PM Re-Inspection required: c9 No 'When corrections have been made, call for re-inspection at 303-234-5933 , I Date: 11/;1.7'1",'7 , Inspector: ....::::...- t- i DO NOT REMOVE THIS NOTICE 11m Ii I r Ir 'IO~'''''' 'fl!f" ~, ..~ 'iiId~ 0'. "..... "'''''''''''(''' ..""_. .1' "~*.Jiillll1'" ,,- :~iiiiii:t~--"'-'''.III "'.'.""'".~"'lV"",","h.',"""" "IIi,.." ..'.""""';6"""",;,~ INSPECTION REQUEST LINE. (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. date Signatu 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building official. 3. If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor ~ violation of the provisions of the building codes or any other ordinance, law, rule or regulation, is subject to field inspections. date signature of contractor/owner I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with the Wheat Ridge Building Code (l.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. 6 nail installation & midroof inspection required. Comments: 4,60<1.00 ESTIMATED PROJECT VALUATION: FEES 144.70 .00 82.84 227.54 Permit Fee Total Valuation Use Tax ** TOTAL ** ** FEE SUMMARY ** r-3 0/ USE: BLOCK/LOT#: UA 0500 .. PARCEL INFO ZONE CODE: SUBDIVISION: ** 01-7246 Any ,Weather Roofing, Inc. Ron Jerman S.Kowalski/M.Kowalsk *** CONTACTS *** owner 303/237-0169 gc 303/234-1539 11/26/2007 OS/24/2008 26 sgs. ISSUED ;, EXPIRES install 30yr dimensional shin;le. 071287 3275 HARLAN ST T/O: I/W shield, PERMIT NO: JOB ADDRESS: DESCRIPTION: Residential Roofmg PERl\;1IT - 071287 \ , City of Wheat Ridge /' . - ,. ,., ,','-_"..Y__.'.' .." .,"'''_'''"VCy',''_,_ _ "''''...'''."''~.':. ""_"'''_'~'''''''''.>;~'.''''~ City of Wheat Ridge Residential Roofmg PERMIT - 071287 PERMIT NO: JOB ADDRESS: DESCRIPTION: 071287 3275 HARLAN ST T/O: I/W sbield, ISSUED: EXPIRES: install 30yr dimensional sbingle. 11/26/2007 OS/24/2008 26 sqs. *** CONTACTS *** owner 303/237-0l69 gc 303/234-1539 Ron Jerman S.Kowalski/M.Kowalsk 01-7246 Any Weather Roofing, Inc. ** PARCEL INFO ZONE CODE: SUBDIVISION: ** UA 0500 USE: BLOCK/LOTl!: r-3 0/ Permit Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED FEES 144.70 .00 82.84 227.54 PROJECT VALUATION: 4,602.00 ** FEE SUMMARY ** ~ Comments: 6 nail installation & midroof inspection required. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of recbrd;that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other ap licable Wheat Ridge rdinances, for work under this permit. Plans subject to field inspection. II-;;).1o-o7 signature of contractor/owner date 1. This permit was issued in accordance with the provisions set forth in your application and is subject tb the laws of the State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire IBO days from the issue date. Requests for an extension must be received prior: to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full' fees shall be paid for a new permit. 4. No.work of any manner shall be done that will change the natural flow of water causing a drainage probl~m. 5. Contractor shall notify the~uilding Inspector twenty-four (24) hours in advance for all inspections ana shall receive written approval on inspection card before proceeding with successive phases of the jOb. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for,nor an- approval of olation of the provisions of the building codes or any other ordinance, law, rule: or regulation. All plan supject to field inspections. Signature 0 date INS~BCTtON RBQVBST LINE. REQUESTS MUST BE MADE BY (303)234-5933 BUILDING OFFICE: (303) 235-2855 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Community Development Department SlNGLEAND TWO-FAM1LY BU1LDlNG PERM1T APPUCAT10N Property Owner: (;!.of-) :::J€R-t-'l~.~ r Property Address: 3;;.. 7 ~ rI ft(lk""-J \.A) r> e""~l"c, e- SO;l 1'( Phone: ~ 37 - <!) I c:. q Contractor License No.: 0 \ I ;;l.1..j to Company: A"'y W.e"n,-eoL (to"-",,, N~ Building Permit Number: Date: Phone: )'34-/5":'5 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Bui/dina Dept. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and,all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. (OWNER)(CONTRACTOR),SIGNED AZ;" t 11.r'~./9" DATE /(-'1(".0--' (OWNER)(CONTRACTDR):PRINTED STEll"''' oS, ILc....:."LSl)'DATE /1-.11.-<>7 Value:$ 4.::.-00. oc Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ Use of.S~ace (description):J"( ..^"'-........... ~::J/ ~ . Descnptlonofwork: ~-b-""~--_._~-( ~~fJ~ 30'~ (G,-~ Sq. Ft.added ;). G;, R BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: IzONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: . Approval: PUBLlC WORKS COMMENTS: Approval: IRE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approvai: Expiration Date: Approval: (4) (5) (6) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning-Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. . This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 180 days. If this permit expires, a new permit may be acquired for a fee of on~-halfthe amount normally required, provided no changes have been or will be made in-the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit f.or, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to fteld inspections.. (1) (2) (3) Chief Building Official DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date: ?~ /yc;? 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: Contractor License No. : Company: JI?,{~n/MJ 3?-- 7:;- /I /y~$l/ S;,7" /9 -f'o L- ~~/7/6-- Phone:.23;/_ 0/6;3 Phone :1/.>/8o/-.:J- OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Use Tax: //J () c..l- -f'f: RL-- / ~ 3r5- ...----: I hereby certify that the setback distances proposed by this pennit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that aU measurements shown, and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat .. e ord' work under this permit. ~ ?- (QWNER)(CONTRACTOR) SIGNE ,v Total: Description ~~L - ?f::- t-/ :) ,,",(../~ ~pdZ//~;o. ~~ca?svZ BUILDING DEPARTMENT USE ONLY Approval: ~~.(lts.; Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: II ~~ll',l~ Expiration Date: Approval: il1IIII "1D'ri1-""uIEelli~'[Jl. .. !.Lr~,,- '~'''''~H''WiN,~4:.., Expiration Date: Approval: II (1) (2) (3) This permit was issued in accordance with the provisions set forth in yapur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of lNheat Ridge, Colorado or any other applicable ordinances of.the City. This permit shall expire if (A) the work authonzed is not commenced within sixty (60) days from Issue dale or (8) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required. provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit No work of any manner shaH be done that wIll change the natural now of water causing a dramage problem Contr'actor shall nollfy Ih" BUIlding InspectOr twenty-tour (24) hours in advance for all inspecttons and shall receive written approval on inspection card before proceedllng with successive pnases of the lob. The issuance or a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordmance, Jaw, rule or regulation. (41 151 (6) For Mayor Chief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION