Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3875 Harlan Street
The City of Wheat Ridge Third Party Form Check list 1 V E d Property Address ;J i'TH►��►�r� =tel Permit Number 4 )f ��nC Kermit Issued Date`-� - -i_'l `� - Per - Owner linforrnation n Property Owner Information c"e''k Property Owner Address '31-75- _G4ary -5'/ InspectoiP Ianformation Inspection Company L C' Inspector Mame }:, i 1,1►�� Inspector Contact info. i -/ 35k Inspector Statement and Acknowledgement * I Nearby acknowledge the roof I am inspecting is 6112 or over. All roofs that are under 6112 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearhy acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's recommendations an spe ificatl ns. Inspector: Elate: PropeLbL Owner Statement of Acknowledgement *I Nearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Ridg wilding rision ;xSpection. Propaery Owner/Agent: — —mate 12 - This original document an ermit card, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th dive Wheat Ridge CO 80000 Draft: Date: 7/26117 Please add noto to .reverse aide The City of Wheat Ridge Inspection Check List notes Mid -Roof R22 8nspecUon NSA [] Pass [_1 Fail F] NfAPass ❑ Fail Structural roof components ❑ NIA Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A Pass ❑ Fail Flashing for roof and walls Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) N/A Pass (� Fail Verify sheathing nail paffern (See Policy & Procedures) N/A Pass ❑ Fail Crickets and saddles where needed N/A Pass ❑ Fail Verify B vent mast Have hoot same gauge as pipe Pi N/A Pass ❑ Fail Verify vent caps ❑ N/A PU Pass [❑ Fail Verify no flashings are damaged or rusted © N/A Pass ❑ Fail Step flashing shall be min. of 4x4 .piece per shingle N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage �j NFA Pass ❑ Fail ice and water shield 2' in heated wall spaces ❑ N/A ! Pass ❑ Fail Underlayments must follow 2012 IRC 12012 IBC 0 N/A Od Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ NJA Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A /IV Pass [71 Fail Dripedge small be rnechanicaiy fastened 12 " QC N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 Pq N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 114:12 slope I Pass ❑ Fail Above roof insulation R-25 N/A ❑ Pass ❑ Fail Below roof residential R -36 l N/A ❑ Pass ❑ Fail Below roof commercial R-32 ]� N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPfl min slope 114:12 slope / must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the leiter for final inspection Metal Roof Shin Requirements N/A ❑ Pass ❑ Fall Metal roof shingles shall not be installed on slope less 3:92 lgl NfA ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fall Metal valley flashing shall extend a min of 8" from the centerline with a min. of 314 " high splash diverter rib built-in at the flow life with sections overlapping a a min. of 4" `tile Roofs Requirements NIA ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-112:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes W, COMpany Name. Inspector signature° Date of Inspection: 5 a-i� The City of Wheat Ridge Inspection Check List notes Final Roof 3:12 »/A ❑ Pass ❑ Fail Metal valley flashing small be the same material as roof D NJA ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a ruin. of 4" Fite Roofs Requirements ❑IN/A ❑ Pass ❑ Fail Clay and concrete file shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment Roof inslppction l�j NIA ❑ Pass ❑ Fai! ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A i Pass ❑ rail Verify that no more than 2 layers of shingles exist in N/A Pass ❑ Fail Flashing for roof and walls Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A Pass ❑ rail Verify sheathing nail pattern (Bee Policy & Procedures) N/A /❑ Pass ❑ Fail Crickets and saddles where needed ❑ N/A U Pass ❑ Fail Verify B vent must have hoof same gauge as pipe [-I N/A Pass ❑ Fail Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged or rusted N/A ❑ Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A [4 Pass ❑ Fail ice and water shield Z in heated wall spaces ❑ N/A Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A �1m Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A] Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC M N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2,12 slope; Exception: detached garages, patios, carports, open on three sides with mire. slope of 1:12 N/A ❑ Pass ❑Fail Modified Bitumen, EPDM, TPO rein slope 1/4:12 slope FAI N/A ❑ Pass ❑ Fail Above roof insulation R-25 Q N/A ❑ Pass ❑ Fail Below roof residential R-38 N/A ❑ Pass ❑ Fail Below roof commercial R-32 M N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications - Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Rauf Shin Requirements ILW N/A ❑ Pa55 ❑ Fail Metal roof shingles shall not be installed on 510pe fess 3:12 »/A ❑ Pass ❑ Fail Metal valley flashing small be the same material as roof D NJA ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a ruin. of 4" Fite Roofs Requirements ❑IN/A ❑ Pass ❑ Fail Clay and concrete file shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name: IVA Inspector signature- t I In Date of Inspection.- 0/ City of Wheat Ridge Residential Roofing PERMIT - 201900785 PERMIT NO: 201900785 ISSUED: 04/25/2019 JOB ADDRESS: 3875 Harlan St EXPIRES: 04/24/2020 JOB DESCRIPTION: Redeck and reroof with OC Duration asphalt shingles, 8/12 pitch, 15.5 squares (House, garage and both sheds) *** CONTACTS *** OWNER (720)460-6106 FEHRENBACHER CORY SUB (720)295-7506 Cody Brown 120171 Spire Roofing LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,000.00 FEES Total Valuation 0.00 Use Tax 126.00 Permit Fee 140.90 ** TOTAL ** 266.90 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75% of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75% of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201900785 max. PERMIT NO: 201900785 ISSUED: 04/25/2019 JOB ADDRESS: 3875 Harlan St EXPIRES: 04/24/2020 JOB DESCRIPTION: Redeck and reroof with OC Duration asphalt shingles, 8/12 pitch, 15.5 squares (House, garage and both sheds) I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this penmt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying pplans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Budding Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Kimberly Cook From: no-reply@ci.wheatridge.co.us Sent: Thursday, April 25, 2019 10:24 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Kim Residential Roofing Permit Application This application is exclusively for new RESIDENTIAL roofing permits and for licensed contractors only. Permits are processed and issued in the order they are received. You will be notified if your contractor's license or insurance has expired. The license and insurance must be current before the permit will be processed. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. The Building Division permit counter is open from 7:30 am to 3:30 pm, Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a RESIDENTIAL reroof permit? How many dwelling units are on the property? Yes Single Family Home PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address 3875 Harlan St Wheatridge co 80033 Cory Fehrenbacher 720-460-6106 na Do you have a signed Yes contract to reroof this property? CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Spire Roofing LLC 120171 303-882-7069 Contractor Email Address cody@spireroofing.com Retype Contractor Email cody@spireroofing.com Address Credit Card Authorization Spire Roofing Signed Credit Card Authorization Form flat.pdf Form DESCRIPTION OF WORK TOTAL SQUARES of 15.5 the entire scope of work: Project Value (contract 6000 value or cost of ALL materials and labor) Are you re -decking the Yes roof? Is the permit for a flat Pitched roof (2:12 pitch or greater) roof, pitched roof, or both? (check all that apply) What is the specific pitch 8/12 of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: 16 Owens Corning Duration Asphalt Comp shingle z Type of material for the Asphalt PITCHED roof: Provide any additional Reroof house, garage, and both sheds. Install new sheathing. detail here on the 16SQ includes all buildings being replaced description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Yes Yes Yes Yes Yes 3 Person Applying for Cody Brown Permit Email not displaying correctly? View it in your browser. aml Ci- n-(5 PA"&,PwM1f# I lI I iiiiiii I A , , I jl��Irjj I 1111� •11,111 N Efeebical: W.R. City License M 1111 - D "t -• # 1w1gJW1;,7ugM- LMwd1W-1r1A= Complete all information on BOTH sides of this form ROOFINGNEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE COMMERCIAL COMMERCIALi ! ?; RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT r COMMERCIAL ACCESSORY + •:. s. E (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY rage, shed, deck. etc.) A. A :MI R REPAIR k A r REPLACEMENT Y k Ilk kM # y #r # PLUMBING � A REPAIR ' d ! d CMENT ELECTRICAL x*L SYSTEMIAPPLIANCE REPAIR #F 1AM # REPLACEMENT OTHER (Describe) (For ALL projects, please prmAde a description of It to �e- pefformed, krJuchng current use of areas, proposed uses, square footage, e4sting cordition and proposed new condition. aDDliance size A44-A40%- `7, 7/,/c)- f' Sq. FULF Gallons Amps Other OWNMCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ...:«. cemfy diat dw sdbwJ ftances proposed 1. l.« .�xa • .r i ri a :. .A.xx.A x. ,: ..... '"Y IR M of A::' •.: Wheat >A+ l > +a 4 :✓„ :p f.♦ u.l t i lA : ;.x • ♦ ':lt ^l,. ¢. .. Vk. M. .; i. `; * •* iM.+. . t I 1 w. 1. 4 i" .,. 't" • tS :.! M »!A A✓: • x i.:. . + ,. 14 ♦. A s.. ... A µ. A • A* I i.* ♦. AA*.-. M t l ! -. w. DEPARTMENTUSE ONLY R x ,. ..J>EPARTMENT OF PLANNING AND DEV LOPMENT Building Permit Number: 6573 .. BUILDING INSPECTION DIVISION - 2 5-2855 CITY OF WHEAT RIDGE Date: 2/9/98 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: 3875 Harlan Street Contractor License No.: 17152 Company: Precise Plumbing OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING ND AGREEMENT Phone: 420-7182 Phone: 534 0881 (OWNER)(CONTRACTOR) SIGNED DATE Construction Value : Permit Fee: Plan Review Fee: Use Tax: Total: $492.00 $22.00 $0.00 ~"'7.56 S29.38 22.00 pp I hereby certify that the setback distances proposed by this pennK appl" tion are accurate, and do not violate applicable ordinances, rules or regulations of the City of Whaat Ridga or covenants. easements orrestrldlons of record; that all. measurements own, and allegations made are accurate; that I have reed and agree to abide by ali condition rinted on this application, and that I ..sume fuli responsibility for compliance with the at Ridge Buiidlng Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for wo u~r this pennK. Use: Description: replace water heater, ready for inspec ion BUILDING DEP RTMENT USE ONLY SIC: Sq. Ft. : Approval: Occupancy : Walls: Roof: Stories: Residential Units : Electrical License No : Company: Plumbing Licens No: Company: Mechanical License No : Company: Expiration Date : Approval: Expiration Date: Approval: Expiration Date : Approval: (1) 1I1is pennIt was Issued In scconlance with the provlslons set forth in r opplicatlon snd is subjec1 to the laws of the ~ of Colonldo and to the Zoning Reguiatlons and BulidinO Code of lM1eat RIdge, Colorado or any other IlcBbiB ordinances of tha City. (2) 1I11s pennli shBII expIIv W (Al the wori< authorized Is not commenced . ,n sIx1y (60) days from issue dete or (B) the building euthorlzed is suspended or a_ for a pertod of 120 days. (3) W this pennli 19XJlim, e new pennIt may be acquired for e rea of onB-hBlf the amount nonnally l1lquired. orovided no chSnges have been or wlli be mode in the origineI plana and ~rIGatiOIlI and any suspension or abandonment 8 not exc:eeded one (1) year. 1f changes are made or if suspension or abandonment exceeds one (1) year, lull fees shall be paid for a new pennll (4sl No work of any manner shall be done that wm change the natural flow water causing a drainage problem. ( Contractor _ notifY the Building 1'- twenty-four (24) hou.. In venee for all Inspections and shall receive written app<ovaI on Inspec1Ion card befonl _ling with succ:esslve pha'" of tho Job. ) The laauanee of. permit or the approvel of drawings and specifications II not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any otherordlnsnee. law, rule or reguistlon. Chief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED B THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HO RS PRIOR TO INSPECTION J DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION. 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH A VENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: Property Owner: r /fe' C:C: PropertY Address: '} <;S? '5- #-"" /' /i- /) s ( Contractor License No.: / 7/ r:l.. Company: fJr~c-I5-e. //..-... (/"? ..z;. c- Phone.: 'f;2 0 - '71 '5'2.. . Phone : 5'.J fI- t!' i' 'if" / - ( OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: t; p). ---- Permit Fee: .:l.::l.. - UseTax:sP.4"S fC>.~n I hereby cemty that the setback distalnces proPOsed by this permrt apPlication are accurate. and do not vIOlate appl,cable ora,nan..... NIe. or "'9Ulabons of the City ot Whe.t Ridge or covenants. easements or restndions of record: that au measurements shown. ana al1eg8tlOns i.made Bnt accurate: tnat I have read and agree to abide by all conditions pnnted on this .ppllCation. ana tn.t I ...ume full ",.QOnSIbility for comp...nee WlII1 tne Whe.l Ridge Buifcfing Code (U.B.C.) ana .11 other .pplIClIble _ Ridge ora.n.n..... for wall< under thl. 1lIInmt. ' (OWNER)(CONTRACTOR) ~IGNED-4 ,~.. ./~ DATE . Description: r.e,/'4 c-e. u1o~-#'r 1/"... ~r .J r-f'ALo1- ?'or /I1,Y'" ~'oYl Total: 2.'t- BUILDING DEPARTMENT USE ONLY A'~;)l' ~'I" .;. Approval: Zoning: ~ ~!J-,' ".'1::'l1!.J:.:J l'..-l Approval: . ~1ftf.W&_kJ_CdlI",**~ Approval: Occupancy: Walls: Roof: Stories : Residential Units : Electrical License No : Company: Plumbing License No : Company: ' Mechanical License No : Company: Expiration Dale: Approval: .3 (PJliis~ulriCl~ Expiration Date: Approval: ~ ;' P~ ~ulntd;~ .:1 Expiration Date: Approval: . ~uldRf,l;il (1) nus pennn was ISSUed Itl aCCOl'dance wnn Ihe provtIIOftIleI for1n In yOOUl IppllCabon and IIluotect ID the &awl of the State at Colorado and 10 the Zoning Regutatlons ana Butldlng CocIe of WhOI Ridge. Co:oraao OIl1ny otner IPPbClbIe OtQlnanclS of the City. (2) This perrnI1 snacl expue rt fA) the wont IUV1Ol'IZeG II not COmrnenc:eG W1tnlft sIXty (60) days from ISSue dale Of' (8) the budding authOnZea .. suspencled or abandonea tor I oenoa of 120 daYS. (3) It INS pennrt a.Dlrel. . new '*'"" may OIl acQuitea fer. fee 01 on..nalf the amount normaUy reow.d. prtMdeCI no d\anOel n..... been at will be ...... in 1M onginIIl pt.n. ana speofk::atlOnS and any suspensaon or .~nctanment nn noI exceeGecI one (1) year. If cnangea Ire mila. or if IUspenalOn or lDanCIOI'Wnent exceea. one 11) year. rutl feeS IhIII be DRI tor . new DemWl. (4) No work of any manner ,I'll" De done thai wall Change tne "alUtal flow of WI"" taluslnq a dratNIOI probIent (5) ContractOr snail nobly tne 8ulldlng lnsgeaor twenty.four (24) hOurs In aoy.nee fOr alllnspecoonS IllCI anaa rltC8lYe wntlen approval on tnlpecaon CIIR1 bIfota pnx::eecIllng Wltn succeSSIVe ONsel of tn. JOb. (6) The ISsuance of II pertrVI or tn. approval or drawings and soeaficatlons snail not be CO"S~ed to De I pe""" for. nor an IPPl"OVIIl of. any 'AQlabOtl of the prtMIlOnI of tne bUlla."; cooes or IIny Diner ordinance. law. t\.I:e or regUiaUGn. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR , CALL; 234-5933 24 HOURS PRIOR TO INSPECTION