Loading...
HomeMy WebLinkAbout3232 Fenton StreetFrwn: rvnL®n wheatndae co us To: C Mme P mas subject: Wine Fm" wb flaks W4 IaWn Date: FrlEay, Nwa 12, 202110:56:05 AM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for yes Solar PV Installation? PROPERTY INFORMATION Property Address 3232 Fenton St. Wheal Ridge CO Property Owner Name Ryan Herz-Thyhsen Property Owner Phone 484-832-2510 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email 0ht513agmail.com Address Attach City of Wheat Herz WheetRiHoA Fledmnic-Payment-Fnrm Mf Ridge Electronic Payment Form - **DO NOT ATTACH A PICTURE OF A CREDIT CARD** CONTRACTOR INFORMATION Contractor Business SunTalk Solar Name Wheat Ridge 120156 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 919306-7955 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email cidaytonCsuntalksolancom Address Retype Contractor ddayton®suntalksolar.com Email Address DESCRIPTION OF WORK Scope of Work Install 4.81 kW solar PV system. GO tied and 8ushmounted to roof of single family dwelling. 13 modules. KIN 4.81 # of Panels 13 Location of Panels Roof of house Structural required Yes Upload engineer letter Hea-Thvsen Reg dance wheat R doe CO Stamn,Ad ndr or pages on 8 112" x 11"only Solar Installation Plan Herz. 3232 Fenton St. Permit stemmed H1 nM Set on 11"x17" only. Project Value (contract 10822 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have 'res been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Denby Gardiner Permit I attest that everything yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying wmedly9 View It in your bmwser V otyl SLT RUC T U R AL RNGJNP.P.R ING, L LC October 13, 2021 To: SunTalk Solar P.O. Box 171W Denier, CO. 80217 Subject CMIR[Mlon Well Hers Thyan Residence 3232 percent ST Wheat Ridge, Co, W212 To Whom R May Concern, Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, CO 80021 530-664-7055 Domusstructural@gmail.com A kabslce obMe Onofthe head Age of Me existing framing system was Pontorused by an audit have of SI Talk Solar as reyue4 from Cbmus Structural Engineering. All review is amid on these observations and the design entena Iced below and only deemed valid if provided information is true and accurate. On the above refermard projeq the mof structural frzming has been reviewed ter additional loading due m Ne Installation 0the solar PV addWon to the roof. The structural review only applies to the section of the roof that is directly an opening the molar W system and Its wpporting elements. The observed roof framing is described below. H freta mndkions differ, The roof structure a(Roof jconsists a composition aningle on mot plywood and stlp sheathing that is supported by 26 rafters of 24 -roc. with ailing joists aging as rafter has. The rafters have a max projected Mrizonval span of 30'-4', with a slope of 24 degrees. The rafters are connMed atthe ridge to a ridge board antl are supported at the eave by a lead bearing wall. The existing rwffaming system a (Roof 1) is judged to beiradical to withstand the two am imposed by one ' note Ilation of the molar pawk.5trucomOf reinforcement is required Sister upgrade is required bar (Roof 1) par all rafters that dirc]ly support molar ". Stltcb new to 12x6 Di lminj onto center of existing mem bar with Simpson SDW 2230D screws @ 16'1 or IRd nails @6"o.c. lap as needed with 4'-0" mini mum lap per attached detail. The spacing a the polar standoffs should bey kept at 48'o.c her landscape and 48' o.c. for poetry it orrenttation, with staggered pattern W ensure proper disMbutian of leads. The scope of this report is Atictly limited to an evaluation of the fastener attachmem, underlying framing antl suppomng structure only. me atummenrs to the existing structure are required to be in a staggered pattern to ensure proper distribution ofmadmg. Ad parri racking and hardware Shan be installed per manufacturer specifications and within specified design limitations. All watemr ^g shall be provided by the manufacturer. Dor us Stwttural Enginamingswervasno responsibility for misuse or improper installation of the solar PV panels or racking. Note: Seismiccheck is not required since Sal and Seemic Di Category(5DCj aB Design Criteria: •Applicable Codes- 20181B41RC. ASCE]-16 Y'.. • Roof Dead Wad =l0 ps'Nurof 1) •• •Roof We Wad =20 pet •_ tttnnn • sound Speed -135 mph Wuld, Exposure C j0 • Roof Snow Wad =30 of 43019 • Anacbment 1-5A6dia. lag screw with 2.5 Inch min. embedment depth, at spacing shown above. Pleaw contact mew" any further quesbonsorcon[erns regarding this project. Dig gned h John A. Calvert sincerely, Date: 2021.10.13 16:41:43-06'00' John Calvert, P.E. "ishat Engineer Hem-Thysen Residence Wheat Ridge CO.Asm 1 OPTION 1 - PARTIAL LENGTH SISTER FASTENERS WITHIN 8- OF EACH END. (3) SCREWS MIX IE] CEILINGJUST VJ SISTER MEMBER CENTERED ON SPAN OF( ) RPFTEA ATTACH TO RE) RAFTER WJ A TOM SA STAGGERED OND SDT (N) SISTER MEMBER CENTERED ON BEAN OF (E) ROPER ATTACH i0 (E) METER WI SIMPSON EMDEN) SCREWS STAGGERED TCP AND BOTTOM 01 BE 0 G. OPTION 2 - PARTIAL OVERLAPPED SISTER BEE LETTER FOR UPGRADE LP LENGTH PND SEE. (N) SISTER MFIER (X) 91SIFTYPXIER E) RAPIER SECTION A -A Si SISTER UPGRADE OPTIONS 1DiEEaDz1 NOTES: I. ALTERNATIVE FASTENER SCHEDULE: 10E NAILS STAGGERED TOP AND BOTTOM AT V O.C. 2. IF UPGRADE LENGTH IS 6FT OR LESS THEN NO OVERLAP IS ALLOWED. 2W Dy� Domus Structural Engineering, LLC o M U S P.O. Box 6966 -& T R U C T U R A l Broomfield, CO 60021 530-664-7055 ENGINEER INC LLC Domusstructural@gmail.wm Gravity Loading Roof Snow Load Calculations 328 psf PV System Weight 4.00 ps= Ground Snow Load= 30 pat X Standoff Sparing= 4,00 ft p,=0.7C,C,lps 6.08 It (ASCE7. Eq 7-1) C,= Exposure Factor- 1 (ASCE7-Table 7-2) C,=Thermal Factor= 1 (ASCE7-Table 73) I= Importance Factor= 1 q= Flat Roof Snow Load= 30.0 psf P, =C'N (ASCE7. Eq 7-2) Cs=Slope Factor= 1 p,= Sloped Roof Snow Load 30.0 Pat PV Dead Load =3 fief (Per Suni Solar) DL Adjusted to 24 Degree Slope 328 psf PV System Weight 4.00 Weight of PV System (Per SunTalk Soler) 3b psi X Standoff Sparing= 4,00 ft Y Standoff Spacing - 6.08 It Standoff Tributary Area 24,33 off Point Loads of Standoffs DL Adjust to 24 Degree Slope 7316 Note: PV standoffs are staggered to ensure proper distribution of loading Root LFre Load =20 pad Note: Roof live two is removed in area's covered by PV anal. Roof Dead Load (Rod 1) Composition Shingle 4.00 Roof Plyal and Skip Shea0ting 3.50 Double 2x6 Rafters @ Mod. 2.30 Vaulted Calling 0.00 (Gelling Not Vaulted) Miscellaneous 0.20 Total Roof DL (Roof f) 10.g Pat DL Adjust to 24 Degree Slope log Pat Herz-11hysen Residence Wheat Ridge CO.xlsm 2 Do" Ed S S Thi I'RA I. E -NG I NE F,R I NC cl.c Wnus SrrucW2l Enakeeenn9, LLC RO. Box 69M poodnrefE. W W i wo-eea-Toss Gomu.awauwl®nm.X.wm Wind Gl lla ns Per ET -16 Components and Cladding ftuvmike (Fq. ffi10.11 War Sww 135 mph EUpoeureCalryory C Rooddi Gale Roof flow Slope 24par reee Mean Roof Heigh 20 ft Agatha i Fres 213a Groan Eleraen 500 ft W 4nWnd Prwwn CakulAme 96=000256'IhatM NE'for (Fq. ffi10.11 Mz&{veure CulpfceN1=090 (Fah 30311 HZU federal hatem= 1,00 (Fig, 2681) U Won UIreollonallly Faem1= 085 (redaW.611 I(e part EkrNan papers- 082 V garbage WW Swag)=135 mal hFlg]OSIR) Risk Gabwy=ll (Fadi1 ad) dh= 2942 — &aMaIIUone WALN 7 Zone 2067 2077 Zaw Y. 1BT 0]T 067 044 GCp= -IGS EGI 31 d9p 0A1 (Fig .2 ) UPIb Refulre= dflbryr -5416 NIT pan21 ASGUpIIA Prepare .IT.10 4400 43 7par 9.6pi 9.b WF %SAi bpi- 100 2.9 2.W YSI l6 3.01217 3 Thaipciep= 4,3 TnWlery Frea= N33 Wild n.11 8.11 Card Used arnibachnnot3Ib 24 planning main he Ale K MMA dd1A dplb SbntlMUFord1 lbl pa Ford Tn,,2 are osew 060 Y. ods oeo 9.49 ads 075 GCp= 1.50 850 349 050 (Fig . 33 3) 33 1 VesIXre -45e58 8 pay AR.I par 1 pa[ (Ep. 39 <d) -190ph AGO Vpllllpndeure(08W)= -1400 -3400 ft At AI pa[ 961 9b qY x 9renbaA Space - 300 100 263 YS 350 Vs V5 TibeSpeaen= Tibetan, Area= 1100 ler 1b aro 2100 It Load ene6010 loon pelade uplMloeB.onr1= -xve -xuM K mM 81 OpIMe k lands maximum iuqm=3nlb SlantloHUPIIft CepaalH =40015 45016 ci 1377 lb demand Therefore, OR Fae CapaaroCbed Faarenar=l-anb'd1a.lag Nommr of heart =f Emdedmenl Gwlh= 2E N"l(UpwiN For shop = An lb Federal happen= 82516 M F.S. d 1.5 8 DOL of 14 Mdro 972It, ordinary a 3n Isdemand MMorq OR He2Thyaen Residenre WFeel Ridge CO.xbm 3 DOMUS &TRUCTURAL E'NG T NE P.R I NC 1.1, Dead Load 10.9 psi PV Load 3.3 psf Sri= Load 30.0 psi Governing Loa! Combo = DL s SL Total Load 44.2 psi Domus Structural Engineering, LLC P.O. Box 6986 Broomfield, GO 80021 530-864-7055 Domussmuctural@gmail.com (Roof 1) PASS- With Framing Upgrades w =88 plf Double 2x6 Rafters @ 24 0 Member Span=10'-4" Member Properties- Based on Upgraded Section Member Size S(inA3) Iill Lumber SplGr Member Spacing Double 2x6 15.13 41.59 DF42 @24"c. c. Check Bantling Stakes Fin psi)= fin x Cd x Cf x Cr (NDB Table 4.3.1) 900 x 1.15 x 13 x 1.15 Allowed Bending Slower =1547.3 psi Maximum Moment=(wLA2)IB = 1180]03 ft# = 14168.43 in# Achual Bending Stress= (Maximum Moment) I S = 936.8 psi Allowed> Actual.. 60.6% Stressed — Therefore, OK Allowed> Actual --15.4%Stressed — Therefore, OK Herz-Thysen Residence, Wheat Ridge CO.xlsm 4 (E =1600000 psi Per NDS) Allowed Deflection (inial Load) = tJ180 0.688 in Defiedion Others Based on = Simple Span Actual Deflection( Total Load) _ (5'w'LA4)1(384'E'I) = 0.341 in =11364 > 1180 Therefore OK Allowed Deflecdon (Live Load) = U240 0.516 in Actual Defection (Live Load) = (5'w'LA4)1(384'E'I) 0.232 in U535 > U240 Therefore OK Cheek Shear Member Area= 16.51ni Fv(psi)=180 psi (NDS Table 4A) Mimed Shear =Fv'A=2970In Max Shsar(V)=w'LI2= 457 lb Allowed> Actual --15.4%Stressed — Therefore, OK Herz-Thysen Residence, Wheat Ridge CO.xlsm 4 A qu 1) LL 2)Re 3) No City of '� W heatR�dgc Cownunnr Devewrnrnr APPROVED Reviswp9j2L QdLQx pagans Plan^ Examiner Date w,,,xj.we� ar„warn.m.. ewmrM rww, wwaoero/wywamer mvW ne ,uym ewpm9 mow qor. nM1aOiwl. IpgY eeww„y rooerw oornenry m wwk r wwei rn raw awia 4 w away a aw r n.+., wai,ene..t n. rm.nw pr «.ra sod person must be present at the timr ed master orjourneyman electrician, solar Installer capable of testing the rapid shut down system. 3232 FENTON ST. PROJECT SUMMARY System Size:4.81 kW Module: (13) REC REC370AA Inverter:(1) SolarEdge SE6000OH—US —1 String of 13 Modules Racking: Rock—It w/Flashing Roof Snow Load: 30 psf Wind Load: 105 mph, Class B 2018 IRC/IBC/IEBC & 2020 NEC Interconnection: Line Side Interconnection (35A Fuse) Roof: 25yr Comp. Shingle (^-10yrs, Good) Single Layer of Shingles Array 1 — Tilt: 24' Azimuth: 270' Installer: Sun Talk Utility: Xcel AHJ: City of Wheatridge CONTENTS 1.0 : Cover Page 1.1 : Site Plan 1.2 : Module Layout 1.3 : Details 2.0 : Single Line Diagram 3.0 : Calculations 3.1 : Placards 3.2 : Placard — Rapid Shutdown 4.0 : NREL PV Watts 5.0 Commissioning 6.0-6.7: Component Specification Sheets Sealed For Existing of & Attachment Only so/z3/2021 by 3 16:4235-06'00' w3,3Tai3n,mimp m g raan.ow .... Pk Spmgera[um'Q r raven n p oeswB Bi rsr View 0 QritIl, ILSa., „ I xsnsio wsxw 9 f �un<or nvz amn.wemrz wr shave r.^.ry Q � -JHkrtm CwMl. e GpjflM[Gen � O w.um a., w12.a..1 g r - to I n a 0.3111 s Rmv3v�� f9,�1`1�P31 PROJECT SUMMARY System Size:4.81 kW Module: (13) REC REC370AA Inverter:(1) SolarEdge SE6000OH—US —1 String of 13 Modules Racking: Rock—It w/Flashing Roof Snow Load: 30 psf Wind Load: 105 mph, Class B 2018 IRC/IBC/IEBC & 2020 NEC Interconnection: Line Side Interconnection (35A Fuse) Roof: 25yr Comp. Shingle (^-10yrs, Good) Single Layer of Shingles Array 1 — Tilt: 24' Azimuth: 270' Installer: Sun Talk Utility: Xcel AHJ: City of Wheatridge CONTENTS 1.0 : Cover Page 1.1 : Site Plan 1.2 : Module Layout 1.3 : Details 2.0 : Single Line Diagram 3.0 : Calculations 3.1 : Placards 3.2 : Placard — Rapid Shutdown 4.0 : NREL PV Watts 5.0 Commissioning 6.0-6.7: Component Specification Sheets Sealed For Existing of & Attachment Only so/z3/2021 by 3 16:4235-06'00' 240 AT 270 AZIMUTH 25YR COMP SHINGLE (SINGLE LAYER) ROOF (-IOYRS, GOOD) ® 18" FIRE SETBACK ® 3' FIRE SETBACK 1 N 3232 FENTON ST n 0 Sister upgrade is required for (Roof 1) on all rafters that directly support solar PV. Stitch new 8'-0" 2x6 DF#2 (min) onto center of existing member. See detail for additional information. 1.1 3232 FENTON ST„ SOLAR LAYOUT SCALES 3/32' = 1 0' EQUIPMENT SCHEDULE O1 MODULES (ZINVERTER 03 FUSED PV DISCONNECT ®MAIN PANEL OUTILITY METER Sealed For Existing Roof & Attachment Only 101132021 N N O Wo 0 QY Sister upgrade is required for (Roof 1) on all rafters that directly support solar PV. Stitch new 8'-0" 2x6 DF#2 (min) onto center of existing member. See detail for additional information. NEMA -'W Junction Dox 2' 4' T IO' -24" 14 9 41'-l1" Sealed For Existing Roof & Attachment Only U S1, R 430191 a 3232 FENTON ST„ RACKING LAYOUT " 1.2 SCALE 3/16' 11'-0' 10/13/2031 1.2 Sister upgrade is required for (Roof 1) on all rafters that directly Support solar PV. Stitch new 8'-0" 2x6 DF#2 (min) onto center of existing member. See detail for additional information. OPTION 1 -PARTIAL LENGTH SISTER ps OF �NUEL EMMVOf F) WLIPPIAU IT nre+ A sNg/ ME eE:L:nL`e `.aooeu.aLro OPTION 2 - PARTIAL OVERLAPPED SISTER ELL LLii LKIO+T ✓LUL LwuwINv 45Ml w PUEu SECTION A -A :urEu �, SISTER UPGRADE OPTIONS ND-'rE 1. KTENIUT VEF D!IEN SC HEDULE: l0EN W ,fEIEI IS TOP ED. 2. f IIPGnAOE LENGTH IS fiFr OR LESS THEN NOOVEFLAP 19 ALLOWED. ATYO,O, Sealed For Existing Roof & Attachment Only 20113/2022 43019 1.3 Approval Notes: 1) P/V array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B) n © /AC I L Ll 2 N G �► I�fi�■�■ o QL9' a TO UTILITY LINE ARRAY SPECIFICATIONS 4.81 kW EQUIPMENT SCHEDULE O(4) IEC REG70AA SOLAR MODULES FEEDER SCHEDULE TPRONDE 1 00 AWG(+), 1 B10 AWG(-) PV GENERAL NOTES (13) REC 370W MODULES IME. 1 0 AWG (G). (-70' LENGTH). (1) MINIMUM PERMANENT SIGNAGE (YELLOW PLACARD, BLACK I STRING OF 13 MODULES ®SCIAR EDGE P{01 OPTMIZERS (EACH SIRING LETTERING}. OF OPnMIZER5 UNITED TO 380VUC NOMINAL OPROWDE 1 00 AWG(+).1 910 ANC(-) (A) ON COYER OF MSIBLE UTILITY DISCONNECT - MBBUT). RAIN -F. 1 00 AWG (G) IN A 3/4° CONDUIT "PHOTOVOLTAIC SYSTEM DISCONNECT' O3 Wmogi ANCnCN BOX. (SEE NOTE 7) (0.W LENGTH). (B) IXJ FRONT COYER OF MAIN PANEL "WARNING: MODULES SPECIFICATIONS OA3/r 3 AWG TIW!-2 1 (G)). CTRNCE THIS PANEL ALSO FED BY SOLAR ELECTRIC SOURCE.' MANUFACTUREPoREC O{ EDGER.2 SESOOOH-US HUB TE (e L D q G/{• CONDUIT (YE NOIF 7) (�3'IENGTIJ. (C) ON BILLING METER AND PV PROD METER - MOOELL REC370AA INMER OUTPUT. IN DC DISCO NECT. A C F UL WR INTEGRATED DISCONNECT. ARC FAULT PROTECTION AND 'PHOTOVOLTAIC SYSTEM CONNECTED' VOO44.1 V INTERNAL sxuNOIN. UL n{I AND IMI IN VMP37.4 V PLAIN T. OTHER THAN THAT GIVEN IN (1) ABOVE MAY BE ISC,10.55 A IMP,990 A (DPROWDE A 2 -POLE 240VAC GOA OUTDOOR . REQUIRED RQGE OVDD-0.24Y./°C NOMA 3R SERVICE RAtEO DISCONNECT WTH (2x) 35A fuses. PHOTOVOLTAIC DISCONNECT (3) PV MODULES. STRING COMBINERS. GFI. OC DISCONNECT. INVERTER SPFr.TFTCATTONS SHALL BE MGBIE. AWES9BIE. LOCKABIE. INVERTER. AC DISCONNECT, AND UNLITY DISCONNECT ARE MANUFACTURER, SOLAREDGE IABELED'PHOTOVOLTAIC AO DISCWNEGY UL-USTED. MODEL, SE6000H-US WTMIN 10 FEET OF ELECTRICAL METER. INVERTER OUTPUT 6.OKW ©UNE SIDE INTERCONNECTON ON CUSTOMER (4) ALL GROUND SYSTEMS ARE BONDED TOGETHER. INVERTER VOLTAGEL 240V 9DE OF METER BEFORE MAIN BREAKER IN INVERTER CURRENT, 25AA EXISTED 240V MAIN EILECTRICAL PANEL MUD (5) INTERCONNECTION MLL BE PER LOCAL UTUTY REQUIREMENTS CONT. CURRENT 31.25A TWA MAIN BREAKER AND TOGA BUSS. (DOUBLE-Pq.E CB OR LINE SIDE TAP). (6) SYSTEM CANNOT BE TESTED ON UNE UNTIL APPROVED BY UTILITY. (7) THE PHOTOVOLTAIC SYSTEM WILL BE INSTALLED IN COMPLIANCE WITH ARTICLE 690 OF THE 2020 NEC. CONDUIT TO COMPLY WITH 690.31. (8) ALL 1WRES MUST BE COPPER AND SIZED FOR A MAXIMUM 2.0% VOLTAGE DROP. Z0o 0 UOQ iww 2.0 ARRAY SPECIFICATIONS 4.81 kW (13) REC 370W MODULES 1 STRING OF 13 MODULES MODULES SPECIFICATIONS MANUFACTURER:REC MODEL:REC370AA VOC:44.1 V VMP:37A V ISC10.55 A IMP:9.90 A aVOO-0.24'%/'C MODULE TO OPTIMIZER (MANUFACTURER WIRE) VOLTAGE: 49.39V x l = 49.39 V AMPS: 10.52Axl.25 = 13.15 A INVERTER SPECIFICATIONS MANUFACTURER: SOLAREDGE MODEL: SE3800H-US INVERTER OUTPUT: 3.BKW INVERTER VOLTAGE, 240V INVERTER CURRENT: 16.OA CONT, CURRENT: 20.OA OPTIMIZER TO JUNCTION BOX #10 AWG PV WIRE, #10(G) VOLTAGE: 380 V (POWER LIMITED) AMPSi 15.0AxI.25 = 18.75 A CONDUCTOR: 40Ax0.8x0.77 = 24.64A 2464 A > 18.75 A PER 690.83)(2)(b) JUNCTION BOX TO INVERTER #10 THWN-2, #10(G) VOLTAGE: 380 V (POWER LIMITED) AMPS: 15.OAxl.25 = 18.75 A CONDUCTOR: 40Ax0.8x0.77 = 24.64 A 24.64 A > 18.75 A PER 690.80)(2)(b) TEMPERATURE FOR (80212) PER ASHRAE: LOWEST: -25'C -13-F HIGHEST, 34'C 93°F TEMPERATURE CALCULATIONS: 49.39V = 44.1V x (1+((-259-259C)x-0.24'%/•C)) 93`F+4•F = 133`F 0.77 CORRECTION FACTOR FOR 90'C 0.65 CORRECTION FACTOR FOR 75'C (TABLE 310.15B2b) INVERTER TO FUSED AC DISCONNECT #6 AWG THWN-2, #6(G) VOLTAGE: 240 V AMPS: 25.OAxl.25 = 31.25 A FUSE: 35A ■If87�1:d10AYN�IJ�lYN�1��1�1173Ntl�IJYN11tlCl #6 AWG THWN-2, #6(G) VOLTAGE: 240 V AMPS: 25.OAxl.25 = 31.25 A FUSE: 35A LINE SIDE INTERCONNECTION MAIN BUS: 100 A ALLOWABLE: 100A A X 120% = 120A 100A MAIN + 35 A PV = 135 A 120A <135A LINE SIDE TAP SYSTEM MEETS NEC 690.64 & 705.11 3.0 I N 3232 FENTON ST EPENTON ST„ PLACARDS 3'1 SCALD 3/32 = 1'-0' �R-lS ON JUNCTION - WARNING: ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE SIDE AND LOAD SIDES MAY BE ENERGIZED. OPERATING CIRCUIT CURRENT: 9.9 A DC OPERATING SYSTEM VOLTAGE: 380 V DC MAXIMUM SYSTEM VOLTAGE: 480 V DC MAXIMUM CIRCUIT CURRENT: 18.8 A DC ON INVERTER: WARNING: THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT. PHOTOVOLTAIC AC DISCONNECT: RATED AC OUTPUT CURRENT: 25.0 A AC NOMINAL OPERATING AC VOLTAGE: 240 V AC ON AC DISCONNECTS: PHOTOVOLTAIC AC DISCONNECT NOMINAL AC VOLTAGE: 240 V AC RATED AC CURRENT: 25.0 A AC WARNING: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED ON MAIN SERVICE PANEL AND UTILITY METER: PHOTOVOLTAIC SYSTEM CONNECTED WARNING: ELECTRICAL SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. WARNING: TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL. MAIN PHOTOVOLTAIC DISCONNECT. ON SERVICE DISCONNECT: SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN. TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY. 3.1 3232 FENTON ST 1 N Papid 5huldown EQUIPMENT SCHEDULE Ol MODULES ©INVERTER O3 FUSED PV DISCONNECT ®MAIN PANEL ©UTILITY METER N W O N m Foo �Z O z o O �WKN ZN<I YNWZm rcn3a 3.2 NOTES Cautions for Interpreting Results: Due to variations and the uncertainties associated with the weather data and the model used to model the PV performance, future months and years may be encountered where the actual PV performance is less than or greater than the values shown in the table. The variations may be as much as 40% for individual months and up to 20% for individual years. Compared to long-term performance over many years, the values in the table are accurate to within 10% to 12%. 4.0 IINREL RESULTS 5,776hwNvear* WMN 111. W NOTES Cautions for Interpreting Results: Due to variations and the uncertainties associated with the weather data and the model used to model the PV performance, future months and years may be encountered where the actual PV performance is less than or greater than the values shown in the table. The variations may be as much as 40% for individual months and up to 20% for individual years. Compared to long-term performance over many years, the values in the table are accurate to within 10% to 12%. 4.0 General Informationi Modules S/N Cell Temp Ambient Temp Array Azlmuth(s)t Net Meter#, o Verify all Labels are Installed o Verify all Covers are Installed o Verify Tools/Trash/Materials are removed am Inverter S/N: ❑ Visually Inspect the Array(s) ❑ Visually Inspect Grounding ❑ Conductivity of Grounding ❑ Verify Polarity at DC Combiner ❑ Measure V DC at DC Combiner Modules/String: __/String Modules/String: __/String String 1 V DC: String 2 V DC: in Inspect Wire Managment in Inspect Conduit/Home Run Voltage at Interconnection:__ in Turn on Main Disco in Turn on Other AC Disco(s) in Verify Inverter Operation in Note Inverter Readings v DC: A DC: V AC: Hz AC:__ AC Output (W):____ Shut System Down as Needed N za m INU XZ60 Xwrc ice, 5.0 REE ALPHA SERIESPRODUCT DATASHEET - El a 4EGRINERAL DATA „e, blood �w OLDER EkitoI AAACHCHI VLwd o��, sm�» S C l O tWAMMTY Y. spul All mplp rl 25 IO VIAS n 10 um.I..,.nn a AS o smysInYArms lis 02M 02M IBVA MAXIMUM It opyrValwatedlibrourys All MARY ""oI,—PAdAr,YAd2S 92% loss 929; .. sss".0,E. All i-) soopoEsit Hme smLAUl m q boost m/seN' MAIMAINVI 25A MEArIVA,lbuird, 251 }!P s mpe 021 — .01 ...101.....,.rt: dzi Tempesturecaely , 11111 - ,.m . .. .,..,.Ld.x...,.,.,',.I..yn . t—vol BEHAVIOUR E�� a _�„ ma°`°°.;neo°T ®R[C cAAnAt R " ":1.:d °rt III ws„w�',°a's m th It .�Vm 6.0 4EGRINERAL DATA umv �w so. 10.1ammv. 1016. As mj e..x.n..e .......... arx..�,. .E.m:01.1 s.w. is teevu.n 1 iee„ 43 Es Issyl imam Host 3byptlaewmx of'.o 6 r 1.etrnzipiv. �..m,.e..e„�A" fESE ... Proddi RK AA IUAV A) 41 I'll bIb ARE WhICIVIVIng-IN) a/s aFz Ed apz apz xomm.v.g-v.P 011 sv, 56e All _w e xa.ll3ard.s 9A2 ARES a ys PoCwly. t 439 44 441 442 443 Sh.HC.EslyV Uy 1049 MA2 loss loss 1061 Isvir Nir,Lt..1d lV15 is, is At ,.. Add Ol Add, ArAbOXI AD 6 209 rE 21 4 07 NOMMaIddersolusy V., IV) VAR BE 352 VAR I AVAC.Momm, Adds) 414 41 5 416 41: 4TT,,7 ShanClUmItCurtyl HO It Rod? WIS 057 woo®ddl.l.so—IIIHIERIVAIIHOVIddlyssiddi M ..amn66µV•utl mn...-•wi.mmmur.r. P�.I �. OLDER EkitoI AAACHCHI VLwd o��, sm�» S C l O tWAMMTY Y. spul All mplp rl 25 IO VIAS n 10 um.I..,.nn a AS o smysInYArms lis 02M 02M IBVA MAXIMUM It opyrValwatedlibrourys All MARY ""oI,—PAdAr,YAd2S 92% loss 929; .. sss".0,E. All i-) soopoEsit Hme smLAUl m q boost m/seN' MAIMAINVI 25A MEArIVA,lbuird, 251 }!P s mpe 021 — .01 ...101.....,.rt: dzi Tempesturecaely , 11111 - ,.m . .. .,..,.Ld.x...,.,.,',.I..yn . t—vol BEHAVIOUR E�� a _�„ ma°`°°.;neo°T ®R[C cAAnAt R " ":1.:d °rt III ws„w�',°a's m th It .�Vm 6.0 Single Phase Energy Hub � Inverter with Prism Technology OT for North America ^" SE3000H-US/SE380OH-US/SE6000H-US/SE760OH-US m 0 G) an Optimized battery storage with HD -Wave technology / Recentbreaking9996 weighted elfdency earn / MultH rebel salable sroage Paul 20M X wers¢ing up / Integrated arc fault pmtedion and Paid subsea, / Smaq ligbtwi and easy To inabll for NEC 3014 NEC 3017 and NEC 3020. per trade arre. Part areas, 690.11 and 69012 / Morula, Pesgp bi ready with 00 onal ,Whr, 11 11 upgraki / Embedded revenue grade production data. Adi / XmupkdnomgehrtullorpamalMmeWckup CIC20 Class 0.5 / Buift-inwnsumplionndenitoMg um EarsexcannerneintotheStalarladgesni ink u, irmi deeper 5" at still, solaredge.com solar / Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US/SE380OH-US/SE6000H-US/SE7600H-USl'I OUTPUT ACON6BIU eu,.red Bi.r M1rva ads, Was Upi up WrT DO eass, 0 rcapnwMewigI arre. Part areas, Wind, ease ,Whr, 11 11 (Ostrander I2ake�sxunrirr 99 star, sxueam.�rmw um WC ink u, irmi 5" at still, INPUT -M W.•NDINAMil 1i hi 11 1 Whites was 0 as OUTPUT ACEIKKUPs ACTLO'Pi (WI.P Oaks A, V Q7 Z55 A hekACC.(,1O.rnPdrTp�rA. he 142 as 30 A TO I eu,.red Bi.r M1rva Per Was Upi use WrT DO eass, 0 rcapnwMewigI arre. Part areas, Wind, wWr ,Whr, 11 11 (Ostrander I2ake�sxunrirr 99 sxueam.�rmw um e, m �x INPUT -M W.•NDINAMil eu,.red Bi.r M1rva Per Was Upi use WrT DO eass, 0 On arre. Part areas, na wWr ,Whr, 11 11 (Ostrander I2ake�sxunrirr eu,.red Bi.r M1rva Per Was ov neraer 0 On Psi un wWr I2ake�sxunrirr 99 sxueam.�rmw eu,.red Bi.r M1rva Takahashi ov neraer Use kWhsaw A,and I2ake�sxunrirr e, Z F N !If Ma Power Optimizer Frame -Mounted C P370 / P401 / P404/ P500 <M Fast mount power optimizers with module -level optimization / spe<leally ae9gnetlm Nnrt.nn mlaaage / (m'hr Iblon p,Anq,V mr<a USA rttl' adwnresann9'nsullation ems I Up II% ore enerzy / Rupe,creffiTenWONT590 solaredgecom / MiagaRzall WI d modules missuch ory fimm manuFac W mg mlererce m FBI il Wing / FBI MANY BAY g b mOTVARe GIBI / Nex1generMSOnTAIntenancellhincEdUbelenel / Mud le-Iesel wWaj sFMtl b�insblkraM fire(gMnvkly solar -•• li PS' PowerIf Optimizer Frame -Mounted, P401 .,,. 11 P,C:'lu Moo���MR.aRIMe� I �.�oan� INPUT MI OUTPUT DURING OPERATION (NNwEROP.M=ERCONNECTED TOMIGRATORY REMEMBERED INVERTER) V,... GUY N. OUTPUT DURING STANDBY NOWEa OPTIMIZED DISCONNECTED FROM 5gMEWE INVERTER OR SOIME04E INVERTER MR UEU I ON RI STANDECRADCOMPLIANCE V GAMBIA,~MM BAR vw�na[emvwm INSTALLATION SPECIFICATIONS OUTPUT DURING OPERATION (NNwEROP.M=ERCONNECTED TOMIGRATORY REMEMBERED INVERTER) V,... OUTPUT DURING STANDBY NOWEa OPTIMIZED DISCONNECTED FROM 5gMEWE INVERTER OR SOIME04E INVERTER MR UEU vPVSI,sf&S.6I RI STANDECRADCOMPLIANCE V GAMBIA,~MM vw�na[emvwm INSTALLATION SPECIFICATIONS iANMuNVMLEvhRI IrAI ABY UNT MAP - I LZ N m UEU vPVSI,sf&S.6I RI AN, MUNEIII iANMuNVMLEvhRI IrAI ABY UNT MAP - I LZ N m array LayouT • Find the required structural attachment points. Mark these using a vertical III chalk line on the center of the rafters. • Spacing may va intlepeanding upon project sµcific Structural requirements; i.e. high show and wind Iwtl areas may require beside bracket spacing in the E -W axis vs. Line maximum spacing. Max spacing Is Meyer portrait promotion and R'br landscape orientation. Consult project layout diagram for project specific bracket spacing on the roof. • Install Rack It Mount to predeterminetl mount spacing. The array skirt sections are the width cfa typical 60 evil module - use the array skirt as a go Ide to IayoutmWuleplacemerrt. Note :Th i distance between the rows of mounts is predated bathe module dimension all plus 13/8' (35morm iag saewshould the installed as tloseto wnterotexposcW shingle as feasible. The mbimum distance between the lag screw and theutlgeofthe shingle is 1/Y. oreenFasTen FI_asHinG insTaILL z oml a paw here WaraWmemmath,lag Wit Backfin with wahrd. autumn Solar mendsane"mank. a Inner the flashing so the test part is under She nen mwofamnem and pushed or rough up dope to poorest Wier Indication, mmogb wmnliont In shingle. Me leading eMe&R,li must but ardimt upperrovornana m award boxes wnenmmued. a Lineup *lot bale with ueenfuen Fashion hole. WWethe IN bat through me Eine bonded warren me aaut rnre, the gaf komr e m the naming and into me or Torque: Meinstall l: MMnm 1(10 WNW lnrhpoina s debasing so She base Wwi and time of was Me vbual ancestor for Warner one as Is when the epoM n the shall lde fifth, barred winter begins to push on the fares as the wamo mmpreffei If using an import wrerch minfill the brothers heedrel, I not m mrr torque the nnmwr You may need to amp and use a nmha to amen the Install. 'The engineer of Besedshall ehe[kcapacity Wrafter W support be screw lading. www.erofastensola oom info@eevfastensolarcom Groun DInG InFormaTlon The raill Rakl[System mry be used W mount and ground so modules that comply MIM1 UL I]N, only seen We sh ific module has then evaluated for mounting and gromi in fompltlMew* the'MIWN inebllapMmeadows Nate GmuMing lug must bensible to inspeaton from the entire perime ,ofthe Narray Multlple0soaroundlial Grounding ensetin Me Wrare multlpetaubeatWygmuNiyderlIXiMWukswillneattobeadjustedrftatMiUCtmpSare ImenNmensure there kYaw'metalmemelnmupon retlgMminq Grounding MelMd gets It 3.0 Men or boats NS row of modules a It 2.04 uayaj bonds EM' rays am akke Qe BumdyCL50i ground lug u nyuired per RoperflowersW 3N modules eared In eider ryMil orlandsmpawyeamben. eonolnG assemel_y ane BonolnG PaTH a i for onAusurs T'= Integrated Bonding 87]-854394] a www.ecrfadensolecom infWWcofadWnsolaecom 871859-3%7 n 6.4 6.6 CrIm « ££oF sten So a v OF£c F sten Solar < |; , {! �| \ \ \ \ ~ / , e � 6.6 From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Electrical Service Change/Upgrade/Electrical Work Permit Application Date: Monday, January 3, 2022 9:59:17 AM Electrical Service Change/Upgrade/Electrical Work Permit Application This application is exclusively for RESIDENTIAL ELECTRICAL SERVICE CHANGE OR UPGRADE (200 amps or less). YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes electrical service change or upgrade - 200 amps or less? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 3232 Fenton St. Property Owner Name Ryan Herz-Thysen Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 484-832-2510 CONTRACTOR INFORMATION Contractor Business Suntalk Solar Name Contractor's License 120156 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-576-7245 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email info@suntalksolar.com Address Retype Contractor info@suntalksolar.com Email Address DESCRIPTION OF WORK Is this an electrical Upgrade service upgrade or change? Number of Amps 200 Location of work House (garage, house, etc) Provide additional Upgrade existing electrical panel to 200A Loadcenter details, if needed. Project Value (contract 2000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Davis Clayton Permit Email not displaying correctly? View it in your browser. From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Solar PV Installation Date: Friday, November 12, 2021 10:56:05 AM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 3232 Fenton St. Wheat Ridge CO Property Owner Name Ryan Herz-Thyhsen Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 484-832-2510 rjht513@gmail.com Herz WheatRidae Electron ic-Payment-Form.odf CONTRACTOR INFORMATION Contractor Business SunTalk Solar Name Wheat Ridge 120156 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 919-306-7955 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email dclayton@suntalksolar.com Address Retype Contractor dclayton@suntalksolar.com Email Address DESCRIPTION OF WORK Scope of Work Install 4.81 MN solar PV system. Grid tied and fIushmounted to roof of single family dwelling. 13 modules. KW 4.81 # of Panels 13 Location of Panels Roof of house Structural required Yes Upload engineer letter Herz-Thvsen Residence Wheat Ridge CO Stamped.pdf or pages on 8 1/2" x 11" only Solar Installation Plan Herz, 3232 Fenton St. Permit Stamped (1).2df Set on 11'x17" only. Project Value (contract 10822 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Denby Gardiner Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. f CITY OF WHEAT RIDGE 1 Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: C1A- P-11(4/ 12d® -r Job Address: 3232 Ffp, ,i St. Permit Number: -1 Qj� 00Q?5-3 ❑ No one available for inspection: TimeO r ? 0 AMRM,) Re -Inspection required: Yes oN1. When corrections have been made, call for re -inspection at 303-234-5933 Date: 6/5-A � Inspector: �ary Lo,eff DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE ~ �'(303) Building Inspection Division (303) 234-5933 ;Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTjON NOTICE Inspection Type: Job Address: Permit Number: z01A)C/5'3 w- Nlid/_04 ❑ No one available for inspection: Time ZANO Re -Inspection required: Yes o When corrections have been made, call for re -inspection at 303-234-5933 Date: VPM Inspector: bq^-e Love` DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201800953 PERMIT NO: 201800953 ISSUED: 04/05/2018 JOB ADDRESS: 3232 Fenton ST EXPIRES: 04/05/2019 JOB DESCRIPTION: Residential reroof permit remove and install 30 yr Tamko Asphalt shingles with redecking 29 squares. Pitch 4/12. House garage and shed. *** CONTACTS *** OWNER (303)990-7428 JONKE KATHLEEN M SUB (720)859-1200 Michael Grear 021189 Alliance Roofing Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 19,219.26 FEES Total Valuation 0.00 Use Tax 403.60 Permit Fee 362.80 ** TOTAL ** 766.40 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201800953 PERMIT N0: 201800953 ISSUED: 04/05/2018 JOB ADDRESS: 3232 Fenton ST EXPIRES: 04/05/2019 JOB DESCRIPTION: Residential reroof permit remove and install 30 yr Tamko Asphalt shingles with redecking 29 squares. Pitch 4/12. House garage and shed. I by in signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this_permrt. I furtlr aftest tl�aYI%am legally authorized to include all entities named within this document as partes to the work to be performed and aI rel tb be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature or OWNER or CONTRACTOR (Circle one) `Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any l� applicabde or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief BCilding Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ALLIANCE <--� 0i n �� 15657 E. Centretech Circle Aurora, CO 80011 (0) 720-859-1200 (F) 720-859-1199 PROPOSAL SUBMITTED TO Date: 11-14-17 Phone: 303-990-7428 Name: Kathleen M Jonke Email: Street: 3232 Fenton St. Street: same City: Wheat Ride city: State/Zip: Colo. 80212 State/Zip: We herebv submit specifications and estimates tnr, CLAIM #300-0120155-2017 Page #1 HOUSE • Removal of existing shingles and dispose of. • Install 7116" OSB over entire roof area, • Ice and water shield at eaves, balance of dry in with 15# felt paper. • Reroof house with 30 -year laminated shingles. $12,229.50 GARAGE • Removal of existing shingles and dispose of. • Install 7/16" OSB over entire roof area, • Install 30 -year laminated shingles, $6,724.17 OUT BUILDING • Removal of existing shingles and dispose of. • Install 15# felt paper. • Install eave and rake metal. • Install 30 -year shingles. $265.59 All ea!Ill101e9: uardaLlt Ma .u;14.V 111 lgmlovW by ro,14 vYy I81m5 are OyfeRd N a1 wrain9, FdihAn 10 pay af! 1(a1r VS IkM ModMl {hig IMllnPeriod w.N tx•rmrt mn;pany b %. 10— CO(IIraCIOI neuter .991""1 Ina11M! trgfdy m IISS pMpRrty It .—y t., 1105 W mNN / AM [ark. seri !m. pllrilale r.— mP rf41, ekrSMan 9'VM m bte aUI01 W, kmale ! WnbaC1. M W18Ct, TniSCShrllaie C.1trN:1 shah t Jnr biMk p ,!ptur ualk',(W miltttn ml ellr otie try twnWnq tx by 11. 'Catryi—" moarar it. 'Jim.ur �.ih At'. m hW wok it gmoletxtL Wthe d1W C1 nsp-ool by o,C uhlr!y an 2w`t —d 1g_ tthe company Or UP- CMMry:r ..1 V* Mak. Wae4915. C—PWy rNeAMa 11181 AS valllf mf (NYS intq!tdon. It 'kb ­W bark is ren:urctl eller 3. Aep{K at dm—tw d.W9. I�SCfa t oI dC IOW R k. WIRIIAIrNA, r'RSf1Y1N q na1CM TN6yiilE, pl V-- oder 10 pati k157rtt:ti0r4 C4 11pany aglY'.e8 d) talrtoml wMk rlReatiBary ETt M1arVARe zIMM n 7lda eSlrmale / r;Mlrad, .VR lief inHudRf1 NaI WIN tai. thv9Ml to yl P.XII'a M a W. IO Maaill A"Qlbedl. _i nwl a ba"l"l. a. l lax 11011111" i rnnbacl ill "pre 2A days k.O dale dnlesa extended al -.,,g by o. warp—j.. Mer 20 1Z. T%v 1Ra — / /— .1 ti -t Cvn q— oporl —",i CA bly axakrl:: burr msuan.O W 1ru'n Mry .3x:1 tiuorce orders W kmh 1. yiaillp. da?'n. tla� r`gnlp7ry rP9"VM the lalht 101n on— the, -lar Ie i UJM w s wee rn accoldame wltn the mos h 3:t; IMerc'sl un AN rx/elt¢I" attvllnAt 4^.ell Iw aUtled al the IAL" M 1� per annum C1Ar1er 1 ynIW.1A: tl] JrlrraT "ff Yt M ;t* tWla, ogR•l91011ay' all 405111. L^OkcWn Pr.11;{mlPy I""91nJ1. RUW bP, iM'LneU by Cn`rpiny ra Pll!Orce tM b+rmt ql i. IC nldlr!'ral fIM i0 tw retlrUPrea. If`SlrKkad berdllSa W a Cfi114eNa11M by bre ITVpr / tyenatAl CW Wacfw, d�3 twnraf0l CAnireGl Of a1ry bens. Rwre wN W o—l—kllry 1Pb 0"l ai W fins- owce'" (19Th) Ot the "b"M i—W.1 lance. 14. S0911er W estmate I CW,a we—tP lh& hel-e trap kill alail.Ay In enkx X110 IN.s n(I1CCme1'I : a mw G. 0--, aenrsal c.1baC301 agrees Aub Mary h nW r Wd,lam any'wo' eaalio- Whw man close hp,/4w is rhe Inpal nemar W fhe pmway arxf p--Vy 9wvarvm ay a�axmn dIr<. P—Mo m 119041{) by COrapam.. 15. Iyarrer r fryraxal [ntNacl[N5 A9t Oe5 lhat e M q it:R new cO1WIK.Mem00el:ny .LGP1.i r'N( V..Ompal f 7 I.&r wwramy does — cove dwn )e to tock fared by kghAeiWv. gale (`danpbJ, hu icane. vx oidp. .Nt nu t. Held resp. .Aai, (w any dh wx m, ­u u b, :TGs M God, h1A910mt, aW c; M I..qn bb)— W 0{taX -Aint sI.— C"Vairy . 64-"1 lC 11.15 Nla bA.WIURrtattN. di4rAl,M;, lAikae. nr CrACkrn9 W Rie rant deck. xraNt . kxar[IeC(Al M a Mlk}119 OR aRf rn, rkkrp M f»Amriys 16 0.- y yRlwlal CR K—or ..kT<W HI that tho I W1 am1 e9W— Cfm1/W11ad51 egian pCMdrC - mlmr . a5 rMOtry dM Wj me NBCA& ARMA, 0—,1 W-1nn w. brteas A1ry tryn rn cwtms WW_i ty'W-0 tordllg praedure8. k/ lrtateliA; W 61AX w0ffdM S d lath maths —t 15 nut Wk—od. 8 QM'IIRr 19—al CMara Onatlr"Mh thm Thr CSklnnle I COrnrixi may w gnl.nred by IA1 i.kymktRra 17. RMMikm a mit Wnbuct 1 eSllrltale hat WN!rI 119aW1 try Oerrlla I gM.nl crWrACIM .Rd IMI by ayrRf^.ily —tractor hw d by die mm{lany Q Nqr R1RA5[aPIrEnL' Q.— —batty Ortram. due onds Oy pMler: tlRRer+d —W. OR airy eWa —k br dw1 anaxaa M Ore e1e ante : ctlrntlll:l 0w rTe - r c«Naclor agrees w:lY sP-c -acro AM wrens of tM e.b we f C.9ten. .7-M la by OWm.+* I y--1 tunlr 1.' bet -- i Q—.1 CMII a — air—. pay cclbacwr Arty la. Th.. 3pRtihGNIMS & tttm5 m 1h. RSII,r19(a' GYararl Sxya!d o,111115.^�11�x���0��5unetse•Je W.' uI11Rf m'aMe.aba needed to 1—plWe 1.1019 y-- --.A a, to Ail tR,M A m are 911Aa tee prd m 1 1 r m kw W ".yk W cwriovN unli,. other ra . r AMOUNT:/f.2/ TERMS: Mutual agreement BY: Bob Challacombe For Alliance Roofing, Inc. Acceptan5P7of Contract —7' Signature of Owner Date Signature of Co -Owner (it applicable) Date Lagenia Reimer��� From: no -reply@ ci.wheatridge.co.us Sent: Thursday, April 5, 2018 10:44 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 3232 Fenton St. Property Owner Name Kathleen Jonke Property Owner Phone 303-990-7428 Number (enter WITH dashes, eg 303-123-4567) 4fo 1 Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Field not completed. Yes img20180405 10345584.pdf` CONTRACTOR INFORMATION Contractor Business Alliance Roofing Inc. Name Contractor's License 021189 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-859-1200 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 15657 E. Centretech Cir. (Primary address of your business) Contractor Email Address bobc@allianceroofinginc.com Retype Contractor Email bobc@allianceroofinginc.com Address DESCRIPTION OF WORK TOTAL SQUARES of 29 the entire scope of work: Project Value (contract 19219.26 value or cost of ALL materials and labor) Are you re -decking the Yes roof? Is the permit for a flat Pitched roof (2:12 pitch or greater) roof, pitched roof, or N both? (check all that apply) What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 4/12 29 Asphalt 30 year Tamko Asphalt House, garage, shed SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal 3 owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Bob Carnes Email not displaying correctly? View it in your browser. AND DEVELOPMENT Building Permit Number: 5286 . 235-2855 RIDGE Date: 6/17/97 AVENUE CO 80215 : 3232 FENTON ST No.: 17789 : Lerew Bros. Roofing, Inc. Phone: 233-4886 Phone: 237-2385 OF UNDERSTANDING AND AGREEMENT ATE Total: $3,400.00 $88.00 $0.00 . $40.80 $128.80 Construction Value : Permit Fee: Plan Review Fee: Use Tax: BUILDING DEPARTMENT USE ONLY SIC: Sq. Fl. : Walls: Roof: Stories: Residential Units : Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: . Expiration Date: Approval: . In ~ with the provisions 88llorth In yopur appucalion and is lubi8cI to 1I1e laws of1l1e state of ~ and to the Zoning g COde of Wheat Ridge. Colorado or any _ ~cabla ordlnancaa of tho Cltl<. ~ (A) the wad< aulhorfzad '" not com_ wItt1m IIxty (60) days lJorn I..... date or (B) 1I1e bullcllnga_ is auopended or ~days . now jlO\tl1It may ba ecqulrad for a fila of _If the amount nonnaHy ""Iulrad. provIdad no cha_ have boon or will ba made In the . . .' and any suspension or abandonment has not exceeded one (1) year. If changes are made or If suspension or abandOnment fulI_ _I ba paid for a now pannk. _ ba dona that will chango 1I1e natural _ of watar cawing a dra\naga probIam. 1I1eau\ldInQ I_r _-four (24) hoWl In advanca lor all rnlpactlono and _ __ appl1lVOI on ~ card befonl .eIl.... ollila lob. tfarthe approval ofdrawings and specifk::ations shall not be construed to be a permit for, nor an approval of, any violation of the provisions ,;01' other Oi"dlnance, law. rule or regulation. spector ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-6933 24 HOURS PRIOR TO INSPECTION -_._~-~,~-----'-_."----'-'--- DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: Property Owner: ~X ~ 4'/C Property Address :.Y,<J"~ /?/l~/? Contractor License No. : /77 c!'? :> ./' companXert!'N~,~$~7 Phone ~f.3'- ..y'cf'd"6 Phone -,(~;>-~ fcP..s- I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to a ide by nditions printed on this application, and that I assume full responsib" or om . nee it heat Ridge Building Code (V. B.C.) and all other applicable Wean . f rk under this permit. Construction Value: Permit Fee: Plan Review Fee: Use Tax: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ONLY Zohil\m.oll"'1fents~ Approval: Zoning: B(illalilIDm.1ifmen~ Approval: p"9blrel~9.!Tlm!ljl~ Approval: Occupancy: Walls: SIC: Sq. Ft.: Roof: Stories: Residential Units: Plumbing License No : Company: Mechanical License No : Company: Electrical License No : Company: Expiration Date: Approval: III 1P.J1I'j~W' Expiration Date: Approval: II BJl1!l....&~:qglteJlJIIII Expiration Date: Approval: . r -i.'~~ .i l4) 5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Gode of V\Itleat Ridge, Colorado or any other. a;:lplicable ordinances of, the City. This permit shaH expire If (A) the work authonzed is not commenced wlthm sixty (60) days from Issue date or (8) the building authorized is suspended or abandoned, for spedod of 120 days. If this permit expires. a new permll may be acquired for a fee of one-half the amount normally required. provided no changes have been OT will be made in the original plans and specifications and any suspensIon or abs_ndonment has not exceeded one (t) year. If changes are made or If suspenSIon or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building lnSfector twenty-four (24) hours in advance for all Inspections and shall receive written approval on inspection card before proceedling WIth successive phases 0 thel"Ob" The issuance of a permit or the approval 0 drawings and specifi,cations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation (1) (2) (3) For Mayor Chief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BYTHE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION