HomeMy WebLinkAbout3415 Kendall Streeti CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: qd 5 - F,Al/ +1 'rH�n'cuj
Job Address: 3417 1(F'441 S_fj
Permit Number: 2VIO02 )qo
lVe
4<11 r
` 'n L% f A.0
%
❑ No one available for inspection: Time 7 't 15 AMt N
,.-
Re -Inspection required: Yes ' No
When corrections have been made, call for re -inspection at 303-234-5933
3
Date: IO03®1r'6 inspector: Done, Love -
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
E -Res. A/C Replacement PERMIT - 201802790
PERMIT NO: 201802790 ISSUED: 10/18/2018
JOB ADDRESS: 3415 Kendall St EXPIRES: 10/18/2019
JOB DESCRIPTION: Residential mechanical -replacing A/C, 3 tons, 13 seers in yard on ground.
Replacing furnace, 80% efficiency, 80k BTUs in basement.
*** CONTACTS ***
OWNER (303)238-2849 STRAYER EVELYN M
SUB (303)688-1897 Andy Swan 150271 Swan Heating & Air Denver
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,804.00
FEES
Total Valuation 0.00
Use Tax 205.88
Permit Fee 204.30
** TOTAL ** 410.18
*** COMMENTS ***
*** CONDITIONS ***
Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required
to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every
level of the structure.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications;
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t7�e legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
6. The ia,%%knce or grantirkof a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
appl` a co a or any , dinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Lagenia Reimer vkq q1V
From: no-reply@ci.wheatridge.co.us
Sent: Thursday, October 18, 2018 11:52 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Replacement Air Conditioner/Evaporative Cooler
Permit Application
Categories: Dina
Residential Replacement Air Conditioner/Evaporative Cooler Permit
Application
This application is exclusively for RESIDENTIAL REPLACEMENT AIR
CONDITIONER OR EVAPORATIVE COOLER - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential replacement
AC or Evaporative Cooler
like for like?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Attach Credit Card
Authorization Form -
**DO NOT ATTACH
RANDOM
DOCUMENTS**
3415 KENDALL ST
EVELYN STRAYER
303-238-2849
EVI ESTRAYER@YAHOO.COM
Scan 004718.pdf
CONTRACTOR INFORMATION
1
Contractor Business
Name
Contractor's License
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-4567)
SWAN HEATING AND AIR
150271
303-688-1897
Contractor Address 6810 BROADWAY ST UNIT N
(Primary address of your
business)
Contractor Email Address PERMITS@SWANHEATING.COM
Retype Contractor Email PERMITS@SWANHEATING.COM
Address
DESCRIPTION OF WORK
What type of replacement Replacement Air Conditioner
unit are you installing?
How many tons is the
unit?
For AC - what is the
SEER?
For Evaporative Coolers,
what is the CFMs?
Where is the unit located
(for example, rooftop,
backyard on ground etc)?
3 V
13
YARD ON GROUND
Is electrical needed for re -Co
hook?
Project Value (contract 4902✓
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
2
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for MELISSA SEVERSON
Permit
Email not displaying correctly? View it in your browser.
Dina Kemp
From: no -reply@ ci.wheatridge.co.us
Sent: Thursday, October 18, 2018 11:48 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Furnace/Boiler Replacement Permit Application
Categories: Dina
Residential Furnace/Boiler Replacement Permit Application
This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or
BOILER - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
replacement residential
furnace or boiler like for
like?
PROPERTY INFORMATION
Property Address 3415 KENDALL ST
Property Owner Name
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Attach Credit Card
Authorization Form -
**DO NOT ATTACHED
RANDOM FORMS**
EVELYN STRAYER
303-238-2849
EVI ESTRAYER@YAHOO.COM
Scan 004718.pdf
CONTRACTOR INFORMATION
Contractor Business SWAN HEATING AND AIR
Name
I
Contractor's License
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address
(Primary address of your
business)
150271
303-688-1897
6810 BROADWAY ST, UNIT N
Contractor Email Address PERMITS@SWANHEATING.COM
Retype Contractor Email
Address
DESCRIPTION OF WORK
PERMITS@SWANHEATING.COM
What type of unit is being Furnace
installed?
Number of BTUs 80000 ✓
What is the efficiency 80 J.
(%) of the unit?
Is the unit GAS or GAS
ELECTRIC?
Where is the furnace or BASEMENT
boiler located (for
example, basement,
crawlspace, etc)?
Project Value (contract 4902 J
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
z
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Person Applying for MELISSA SEVERSON
Permit
Email not displaying correctly? View it in your browser.
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day
PERMIT: /?1r,D,5ADDRESS '�'% /--) I.
- JOB CODE:
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
'I1
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid-Roof;-�,'
'I1
307 Metal / Lath / Stucco
`
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONAL INSPECTIONS
PERMIT:ADDRESS:%S� 9 - _ JOB CODE:
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
11408 Final Plumbing Commercial
409 Final Roof
410 Final Window/Door"
411 Landscape/Park/Planning*
Inspections from these entities shall be requested
one week in advance.
"For landscaping and parking inspections please
call 303-235-2846
**For ROW and drainage inspections please call
303-235-2861
***For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works**
413 Flood plain Inspection**
414 Fire Insp. / Fire Protection***
415 Public Works Final**
416 Storm Water Mgmt.**
417 Zoning Final Inspection*
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
Property Address
Permit Number
Permit Issued Date
The City of Wheat Ridge
Third Party Form Check List
�y1 �%eic�crf/ 57—
Owner Information
Property Owner Information
Property Owner Address
Inspector Information
Inspection Company _ t
Inspector Name
Inspector Contact info.
Fy e_.�I Y .4-2Gcy
q/S 16eroc da l (
7&0 &6,0 15—/ 7
Inspector Statement and Acknowledgement
' I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs
that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept.
* I hearby acknowledge the roofing system for the referenced building has been inspected
and found to be in compliance with the minimum requirements of the 2012 IRC and 2012
IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's
recommendations and specifications.
Inspector:`>,,r , Ly t; ,1 c� Date:
Property Owner Statement of Acknowledgement
*1 hearby acknowledge that I am the owner of the building referenced above and I give
my consent for the listed third -party inspection company to perform my roof inspection
in lieu of the City of Wheat Ridge B 'Iding Division inspection.
Propery Owner/Agent:
�; , ��,,— Date;
This original document and permit card, as well as the roofing check list, must be submitted tt
the Chief Building Official within seven days of the final inspection.
Drop off in person
Permit counter 2nd floor
7500 W. 29th Ave
Wheat Ridge CO 80033
Draft Date: 7/26/17
Please add note to reverse side
�ZN/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
'.{ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
❑ N/A
N/A
N/A
N/A
N/A
N/A
Roof Inspection
(_( Fai!
❑ Pass
❑ Fail
f)�_Fass
❑ Fail
❑ Pass
❑ Fail
<aPass
❑ Fail
❑ Pass
❑ Fail
❑ Pass
(_( Fai!
❑ Pass
❑ Fait
Q Pass
❑ Fail
ass
❑ Fail
Z Pass ❑ Fail
lPass ❑ Fail
❑ Pass ❑ Fail
Er Pass
❑ Fail
Pass
❑ Fail
Pass
❑ Fail
4 Pass
El Fail
Vass
❑ Fail
0 Pass
❑ Fail
J`— ass
❑ Fail
❑ Pass
❑ Fail
❑ Pass
❑ Fait
❑ Pass
❑ Fail
❑ Pass
❑ Fail
❑ Pass ❑ Fail
The City of Wheat Ridge
Inspection Check List notes
Mid -Roof
Structural roof components
Verify that no more than 2 layers of shingles exist
Flashing for roof and walls
If new sheathing is installed verify that it is listed in the
permit description (Valuation must be adjusted)
Verify sheathing nail pattern (See Policy & Procedures)
Crickets and saddles where needed
Verify B vent must have boot same gauge as pipe
Verify vent caps
Verify no flashings are damaged or rusted
Step flashing shall be min. of 4x4 piece per shingle
Verify scuppers allow for proper drainage
Ice and water shield Z in heated wall spaces
Underlayments must follow 2012 IRC / 2012 IBC
Verify roof slope for proper drainage
Dripedge shall have min of 2" overlap
Dripedge should extend down min 2" past roof deck
Dripedge shall be mechanicaly fastened 12" OC
90 LB roll roofing shall not be applied to roof slopes
less than 2:12 slope: Exception, detached garages,
Patios, carports, open on three sides with min. slope of
1:'12
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
Above roof insulation R-25
Below roof residential R-38
Below roof commercial R-32
Modified Bitumen, EPDM, TPO min slope 114:12 slope
must be installed in accordance with the manufacturers
specifications- Must have manufactures letter of
warranty with the add— th
Metal Roof Shingles Requirements ss on a letter for final inspection
❑ Pass ❑ Fail Metal roof shingles shall not be installed on Slope 1055
3:12
/N/AEJPass ElFail Metal valley flashing shall be the same material as roof
N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the
centerline with a min. of 3/4 " high splash diverter
rib built-in at the flow line with sections overlapping a
a min. of 4"
_Tile Roofs Requirements
N/A ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-1/2:12 slope
Slopes 4:12 and under require double underlayment
VA
The City of Wheat Ridge
Inspection Check List notes
Mid -Roof
Notes
-14-
,"I
iii /_ /- LC V-
1 -
Company Name:�tL�-
Inspector signature:
Date of Inspection:
The City of Wheat Ridge
Inspection Check List notes
Final Roof
Roof Insoection
❑ N/A
❑ Pass
❑ Fail
❑ N/A
.Pass
❑ Fail
Structural roof components
EO�N/A
9 Pass
❑ Fail
Verify that no more than 2 layers of
N/A
Pass
❑ Fail
shingles exist
Flashing for roof and walls
❑ Pass
❑ Fail
If new sheathing is installed verify i '
nfy that t !s listed in the
permit description (Valuation must be adjusted)
[9 -N/A
❑ Pass
❑ Fail
Verify sheathing nail pattern (See Policy & Procedures)
/a
El- Pass
❑ Fail
Crickets and saddles where needed
El N/A
3ass
❑ Fail
Verify B vent must have boot same gauge as pipe
❑ N/A
O'Pass
❑ Fail
Verify vent caps
❑ N/A
,'Pass
❑ Fail
Verify no flashings are damaged or rusted
❑ N/A
Z Pass
❑ Fail
Step flashing shall be min. of 4x4 piece per shingle
J9 -N/A
❑ Pass
❑ Fail
Verify scuppers allow for proper drainage
❑ N/A
J4 Pass
❑ Fail
Ice and water shield 2' in heated wall spaces
❑ N/A
Pass
❑ Fail
Underlayments must follow 2012 IRC 12012 IBC
N/A
EJ N/A
RRr
YJ Pass
❑ Fail
Verify roof slope for proper drainage
❑ N/A
Pass
❑ Fail
Dripedge shall have min of 2" overlap
❑ N/A
]'Pass
❑ Fail
Dripedge should extend down min 2" past roof deck
❑ N/A
Pass
❑ Fail
Dripedge shall be mechanicaly fastened 12" OC
❑ N/A
Pass
❑ Fail
90 LB roll roofing shall not be applied to roof
slopes
less than 2:12 slope; Exception: detached garages,
patios, carports, open on three sides with min. slope of
1:12
N/A
❑ Pass
❑ Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
N/A
❑ Pass
❑ Fail
Above roof insulation R-25
N/A
❑ Pass
❑ Fail
Below roof residential R-38
N/A
❑ Pass
❑ Fail
Below roof commercial R-32
N/A
❑ Pass
❑ Fail
Modified Bitumen, EPDM, TPO min slope 1/4:12 slope
must be installed in accordance with the manufacturer's
specifications - Must have manufacturer's letter of
warranty with the address on the letter for final inspection
Metal Roof Shingles Requirements
N/A
❑ Pass
❑ Fail
Metal roof shingles shall not be installed on slope less
i
3:12
N/A
❑ Pass
❑ Fail
Metal valley flashing shall be the same material as roof
N/A
❑ Pass
❑ Fail
Metal valley flashing shall extend a min of 8" from the
centerline with a min. of 3/4 " high splash diverter
rib built-in at the flow line with sections overlapping a
a min. of 4"
Tile Roofs Requirements
N/A
❑ Pass
❑ Fail
Clay and concrete tile shall have a min. 2-112:12 slope
Slopes 4:12 and under require double undedayment
The City of Wheat Ridge
Inspection Check List notes
Final Roof
Notes
,tom 1L ✓ 10 r C- oz p Lt-(-(
b>
Company Name: L c� L
Inspector signature:
Date of Inspection:
a
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: tv C 9 - � a )
Job Address: "3�► I �' Kern c), 11 5-�
Permit Number: `3 D I$ O o-9 S-73
1 V o 4-- A /"' P r�o � e Cl
A/ o dh ,V - r --o o-4- r --e c, o r c/ &d / `n S y54e1n _
T� 4 C, r- jnf P� /1 5 N, it T e O /1 rY � U r -4e C).
Ilei o e,
1CfGP m /71 c� TP93ct� 1 v)�/fiekar(�
❑ No one available for inspection: Time `a = sg -OM PM
Re -inspection required: es
When corrections have been made, call for re -inspection at 303-234-5933
Date: /1 1Inspector: —f7
DO NOT REMOVE THIS NOTICE
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
City of Wheat Ridge
j
Residential Roofing PERMIT -
201800253
PERMIT NO:
201800253
ISSUED:
01/25/2018
JOB ADDRESS:
3415 Kendall ST
EXPIRES:
01/25/2019
JOB DESCRIPTION:
Residential re -roof on house and 2
sheds with laminate
asphalt shingles
with 4/12 and 1.5 squares. On flat
portion 7.93 Modbit and no pitch. Total
number of squares is 9.43.
*** CONTACTS ***
OWNER (303)238-2849 STRAYER EVELYN M
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE:
UA / Unassigned
SUBDIVISION CODE:
2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#:
0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION:
4,704.28
FEES
Total Valuation
0.00
Use Tax
98.79
Permit Fee
125.05
** TOTAL **
223.84
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
City of Wheat Ridge
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
thispenn�t. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' acco�m~panying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new pen -nit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building OflTcial and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not pretpeed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting *pcermitshall not be construed to be a permit for, or an approval of, an violation of any provision of any
applic�b e co $ or #ny ore or regulation of this jurisdiction. Approval of work is subject to field inspection.
°
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Residential Roofing PERMIT -
201800253
11;0
PERMIT NO:
201800253
ISSUED:
01/25/2018
JOB ADDRESS:
3415 Kendall ST
EXPIRES:
01/25/2019
JOB DESCRIPTION:
Residential re -roof on house and 2
sheds with laminate asphalt shingles
with 4/12 and 1.5 squares. On flat
portion 7.93
Modbit and no pitch. Total
number of squares is 9.43.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
thispenn�t. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' acco�m~panying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new pen -nit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building OflTcial and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not pretpeed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting *pcermitshall not be construed to be a permit for, or an approval of, an violation of any provision of any
applic�b e co $ or #ny ore or regulation of this jurisdiction. Approval of work is subject to field inspection.
°
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dina Kemp
From: no -reply@ ci.wheatridge.co.us
Sent: Wednesday, January 24, 2018 5:48 PM
To: CommDev Permits
Subject: Online Form Submittal: Residential Roofing Permit Application
Categories: Dina
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
3415 Kendall St
Evelyn Strayer
Property Owner Phone 303-238-2849
Number (enter WITH
dashes, eg 303-123-4567)
�'aa31
Property Owner Email
Address
Do you have a signed
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
Field not completed.
Yes
Attach Copy of Executed Strayer contract.ipA
Contract
CONTRACTOR INFORMATION
Contractor Business
Name
Contractor's License
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-4567)
Blackadar Construction, Inc
070057
303-274-8677
Contractor Address 6800 W 5th Ave, Lakewood CO 80226
(Primary address of your
business)
Contractor Email Address tighe@blackadarconstruction.com
Retype Contractor Email tighe@blackadarconstruction.com
Address
DESCRIPTION OF WORK
TOTAL SQUARES of
the entire scope of work:
Project Value (contract
value or cost of ALL
materials and labor)
Are you re -decking the
roof?
Is the permit for a flat
roof, pitched roof, or
9.43
4704.28
M
Flat roof (less than 2:12 pitch), Pitched roof (2:12 pitch or
greater)
2
both? (check all that
apply)
What is the pitch of the 0
FLAT roof?
How many squares are 7.93
part of the FLAT roof?
Describe the roofing modified bitumen
material for the FLAT
roof:
Type of material for the Other (specify below)
FLAT roof:
If "Other" is selected modified bitumen
above, describe here:
What is the specific pitch 4/12
of the PITCHED roof?
How many squares are 1.5
part of the PITCHED
roof.?
Describe the roofing laminate shingles
materials for the
PITCHED roof:
Type of material for the Asphalt
PITCHED roof:
Provide any additional shingled roof: 2 sheds
detail here on the
description of work. (Is
this for a house or
garage? Etc)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
3
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Name of Applicant Tighe Blackadar
Email not displaying correctly? View it in your browser.
Blackadar Construction, Inc.
6800 W. 5th Avenue
Lakewood, CO 80226
303-274-8677 (Phone)
303-462-4967 (Fax)
blackadarconstr@aol.com
CONTRACT
Date
Estimate #
10/20/2017
17-643
Authorized Signature
Customer Signature"
Tighe Blackadar, President - Blackadar Construction, Inc.
Date of Acceptance ��� J -/ 7
Name / Address
Ship To
Evie Strayer
Evie Strayer
3415 Kendall Street
3415 Kendall Street
Wheat Ridge, CO 80033
Wheat Ridge, CO 80033
Description
Qty
Cost
Total
USAA Claim Reference: 007842967-12 Member: 007843967 Policy: 0078426967/90A L/R Number: 012
1-800-531-8669 Claim Rep: Jeff Todd HCRI 704-430-7654
3. R & R Chimney flashing - large
1
443.39
443.39
4. R & R Rain cap 4-5"
1
33.69
33.69
5. R & R Exhaust cap 6-8"
2
81.57
163.14
6. R & R Modified Bitumen roof
7.93
397.57
3,152.73
7. Aluminum coating - without fiber
792.51
0.71
562.68
16. Remove, tear off, haul and dispose of comp. shingles
0.5
51.30
25.65
17. Laminated comp. shingles w/felt
0.67
228.48
153.08
18. Remove 3 -tab shingles
0.1
49.03
4.90
19. 3 -tab comp. shingles
0.33
211.40
69.76
Sales tax
1
95.26
95.26
Additional charges to be submitted to insurance for permit and any other items as allowed in a supplemental
invoice on completion. All insurance monies received per supplemental invoice to be made payable to
Blackadar Construction, Inc.
Blackadar Construction, Inc. guarantees that all materials will be specified above. Blackadar Construction,
Inc. will perform this part of the contract in manner consistent with roofing industry standards. Performance
by Blackadar Construction, Inc. is subject to strikes, accidents, and delays beyond the control of Blackadar
Construction Inc.
Blackadar Construction, Inc. is not responsible for any damage to the property before the roof is applied.
Blackadar Construction. Inc. carries Public Liability Insurance. Three days after acceptance, if canceled,
customer must pay for any restocking charges; permit fee, or any other costs that Blackadar Construction, Inc.
has incurred from the acceptance of this proposal.
The undersigned agrees to be liable for the reasonable additional costs necessitated by his request for a charge
in the above specification, and that Blackadar Construction, Inc. will be bound by such a change in
specifications only if it is in writing. Owner to carry fire, tornado and other appropriate casualty insurance.
The undersigned assumes responsibility to verify accepted shingle types and colors with any community
covenants that may exist.
This contract has been read and understood by both parties.
This contract may be withdrawn by us if not accepted within 10 days.
Total $4,704.28
Authorized Signature
Customer Signature"
Tighe Blackadar, President - Blackadar Construction, Inc.
Date of Acceptance ��� J -/ 7
Certificate of Completion
AND/OR
Compliance
CITY OF WHEAT RIDGE
7500 W. 29TH AVENUE
WHEAT RIDGE, COLORADO 80033
THIS CERTIFICATE VERIFIES THAT THE PROPERTY DESCRIBED BELOW, DOES
COMPLY WITH THE WHEAT RIDGE BUILDING CODE, ZONING AND OTHER
RELATED LAND USE AND DEVELOPMENT LAWS OF THE CITY OF WHEAT RIDGE
FOR THE FOLLOWING PURPOSE.
PERMIT # 15869
Single Family Addition / Remodel/Carport
OWNER: Richard Strayer ADDRESS: 3415 Kendall Street
PROPERTY ADDRESS: 3415 Kendall Street. Wheat Ridge. CO 80033
CONTRACTOR: Porter Builders. Inc.
ZONING ADMINISTRATOR
DATE 1/2/2004 CHIEF BUILDING OFFICIAL
Building Permit Number: 15869
o : ~ 3-x--~~("
Cavd:~~~\~,I1\C
___----.J
Address:
3415 KENDALL ST
Description:
ROOM ADDITION, CARPORT, FAMILY ROOM,
BEDROOM BATH & KITCHEN REMODEL.
I nspection List
I Number I Type Aooroval Remarks
41320 RP,RM,RF 10/10/2003 OK/OM
41406 INS 1 0/16/2003 OK/OM
41439 DWS 1 0/21/2003 ok/dm
41469 E-SERV 10/22/2003 ok/dm EMR 10/28/03
42403 FE 1/2/2004 OK/eel
42404 FP 1/2/2004 OK/eel
42405 FM 1/2/2004 OK/eel
42406 ROOF 1/2/2004 OK/eel .
42407 FB 1/2/2004 OK/eel
FIND I
INSPECTIONS WILL NOT BE MADE UNLESS
.
THIS CARD IS POSTED ON THE BUILDING SJTE ,
24 HOURS NOTICE REQUIRED FOR INSPECTIONS'"
WHEAT RIDGE, COLORADO
7500 WEST 29th AVENUE (303) 234-5933
INSPECTION RECORD
F~ 'i (7
BUILDING PERMIT NO. . ),) (,.
J.';',/ ,Jr..
OWNER ((' if). ,! "(Ii ('f" I
',,) P' I
CONTRACTOR I? ) . / (. ,. '1 {; Iii f 1..5
,
DATE ISSUED
- 1,.- I
'! r:-:> I .~
,
.'~II/.(I;}, (',: I;'" I L I
! t It! (~( it ( .
I TYPE I OCCUPANCY
JOB ADDRESS
; 111' ;', c...",
.c' ,,) /: l. 1(/ j U' I I
':/
'..~) ,
Iii (' .
SETBACKS FROM PROPERTY LINES: NORTH
SOUTH
EAST
WEST
INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB
INSPECTION I DATE I INSPECTOR
Foundations
Footings
Caissons
Reinforcing or Monolithic
Weatherproofing " ./r -rJ._fc~ d /.-.
POUR No CONCRETE UNTIL ABOVE HAS BEEN SIGNED
Concrete Slab Floor:
Electrical (Ground Work)
Plumbing (Ground Work)
Heating (Ground Work)
Do NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED
Rough Electrical
Rough Plumbing
Air Test Gas Piping
Rough Heating & Ventilation
ck,
<"I<'-
<9J
Framing
Insulation
~
C);e- 10'" (,-,,'
Drywall Nailing
Roofing
Refrigeration
Electrical Underground
Final
Electrical of 1_".0,/ \ vAt'
Plumbing uP, /-2. -oy \ /
Heating & Ventilation b'{ I ~,....-"y TI,f;. it""
Frame ok"' / _7-..~ vI-( J
R.OW. & Drainage /
Fire Department
Parking & Landscaping
,
OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF
OCCUPANCY IS ISSUED
PROTECT THIS CARD FROM THE WEATHER
D&B ENGINEERING
DRILLING, INC. CONTRACTORS
(?)
ADSC: AN INTERNATIONAL ASSOCIATION
01' FOUNDATION DRILLING CONTRACTORS
5135 Ward Road. Wheat Ridge, Colorado 80033 . Office (303) 423-6834/ Fax (303) 423-0603
July 30, 2003
~
Porter Builder, Inc.
7150 Pierson Court
Arvada. Colorado 80004
Attn: Mr. Dave Porter
?L\-l~
/'
Ref: K7726
Dear Mr. Porter,
Please accept this letter describing the materials and methods used for the installation of A.B, Chance Helical Piers for the
addition to the residence located at 3415 Kendall Street in Wheat Ridge, Colorado.
Eight piers were installed on July 25. 2003 at locations specified by Porter Builder, Inc. The piers were installed to
accommodate a design load of 25,000 pounds each as specified by the project engineer, Anchor Engineering. Inc. The piers
were installed to depths ranging from 19 to 38 feet below grade. The piers were installed to a minimum torque of 5.000 ft-
Ibs.
The following A.B. Chance materials were used to construct the piers. All bolts used to connect 1-1/2 inch shaft extensions
and lead sections were 314 inch ASTM A320. Grade L7:
[~ Lead Section (Catalog Number)
i 5' Lang, 1 -1/2 ;!1ch square shan, 8 inch helix
, (C'-{ 0007
i :o,). -I
I
L._.
Extension
(Catalog Number) _
_, foot long, 1-1/2 inch !;quare shan
(CI50-0047)
5 foot long. 1-1/2 inch square shaft
(C 150.000S)
Gcn.:.~r"lIy acceptlJd prGctice fOi th~ instalJati\Jn of helical piers, as well as demonstrated in A.B. Chance lnstallatlon
Certification Training, involves the measurement Oind monitoring of the torque required to install the pier. Torque was
monitored during installation of the piers using a pressure gauge calibrated to measure foot-pounds of torque. The torque is
monitored to evaluate soil conditions as well as evaiuate the load capacity of the installed pier. An empirical factor of 101ft
is applied to the foot-pounds of torque measured to evaluate the bearing capacity of the pier (i.e. torque of 5,000 ft-Ibs is
"enemlly equivalent to an ultimate load capacity of ,10,000 pounds). All piers were installed by A.B. Chance Certified
if1:ilail;'ltioll personnel.
Kevin ~kl'.eill, p.E.
[rlginter
if )'0U require any additional infommtion please do not hc.;iratc: to call me.
Sincerely,
1
(
L
Ti
I
"-
i
+-
-}
~~
~W
VENEER
WALL
x
ff.
~
--,
l:;'
81 (\(,IlIM~
H'.""
I~
____1. ·
L~: :--
4; --r-
I~
r;~ ~~::' .- fl us
u ,.....
RFnWOOD
@
ru"
RE:
::: 1~
r--
I
I
I
I
I
x 2'
D
i="VICTlIU/,\
'"
SP ACED ~~~'-~)
J:YI<:::TI~If' --
",\;1 ,..<< R INn A l()M
-"
-----.. ~~!: Ie. FYIC'TlUf'
I r.....-~ ,. .~v nON R -. 'v lI'tU
U 5~:~. OR KWlK II ~- ~(,REWS
r"r'II .. ........' ~ t.l IN 'UI- Tt"' - ---
_. . _ _ -'I"' A\,;INl; ~ >v"L. 11__ ~\';Kt:WS 0
, II:.KtU EXI STlN G
~'L..:. Y i r- ----1 I
~, I I Y I' 'Ir- - ~
I i '( I' 11' " ~
/ I I " 11'
~ I I
~/1 - r- -+-
t I I
~l/.-
!
51
tEAM 'Ol.;KfT
~
WAU
I
1//
!//1
~
1-
//
/'
/
/
,
II
I
I
V
I
I !
V
I
II
-
/// z:z:z:z:2 z:z // '/'/"7
//
~ft
'00
r
'r
;r
~
~vr
~
~
~
rl
1
:/
~
RI fl~~I~~G BETWEEN
vi nVl-v
'A~IM~
tU"V
/', ~/'/----/
YT'~
- --1
~
RF.ADtfUf"\
'I""
~
\-f"
RI ()(,IlIM(; BETWEEN
~
___ .:1 <f
<f M rl
1I""\r-n. -
r<tuWOOD
- ~
j/16 'V
.. iII.'-
, ANl '....no
""" VI'
@
J4
. J
-iI____----,..,-/./
::: l'
I
I
r
! - '\
I
PIERS TO BE
UN
('f'i ft ..
_.......t' 'tv
t"n .---
..JIIVI r :;)UN
1 4; ---
nANl,;tK
~
I~TARI
mllll~~;~ ~
'\" ----ow.
I' T' ~ I' 'I' 1,111III1 1 ""i
I 1
I
L
-
II
____ 1
T
n~T~R~
9Y1.
II
1 r '1 r
I
I II
I
I
I
- III
I
I
I
Ij
, 0 @
1
T
I
~1
I
,-
1l! I -I -
-.J I f\"
T- ::-J j
1
....-
'uCKET
~n
VI ( ~(IN 'i1J1L IlL
I AT c.=;t..:~t"11-
" t ...n
iWUr-nt'
"'" u'elL-I''':>
;.-
~!~~
~UWUI:.r<
O.C..
-
L4 )(
~
I
=-
~~ I:~
nn-
t'KUVII :
r:nt\. "'Pu
:)::.::-;~~. ....... ~J' TO
_ -- ....:>
j. ll. ....., ,- ·
AN 'unD R()I T(
ullvflVr\ ,.....v:-__i~ @
r'\n- ~--
._ ,...,.. t'KU VI DI:.
roB '"'-
n'""-' .. .:>r1UWN
r\uVIUt
....
r",uVIUt
..
~(~~~~~
"_ "'" "\.\1-
,.... r-\ -
tJ_tVA nrUJ
vn
,v~
AI {)(,IIIM~
'"" '" v
CC~JT!~JI U\II~
S'rrEC~
POWDER
roll ._-
.../lUYII ' ~VN
1
I
I
~
~.
\
4
\
\
i
APPROVED
Subject to Field Inspections
Wheat Ridge Building Dept.
StpA.tJ~_~::~3~t\
~~:J.~~~'\':'"''''
~
. nrat>J
Vi "II.
Rr"11ID-~& llr-ll.
HI_I.i CJ'\J!
;~~ ;
=:\
--
f
r==9r
1~~
r,i~
UJ
flI
I
I
I I
w-
t,~//
I=--
~~I
======= -= -
MAX.. EA VE D,~:-~"';-::u-lft.1
_, 'I
~
COIIIUU
It , ll-V iYU 'II
1 ""n...1. t"'.. ,-,H
_ 'I . Jr1t\JN r\
I 111"""1
n
SHEA TLfING
NAil Ikl~
.....,'IIIV
81 nrl(~t..lf"
..v
,117
I
-I
. ~ ~
'~lIvlr::>UN @
C'T A ^.---
V\}L.I'\
a""--
M< ~ nl u...,,\1:.
SHF A TWI hJ I'
__ I i II 1'1"
I ~1/PlAN
~
_I ~ II
~ -
-
J
-
-
J
~A TI-lING
NAlUNG
,~S'rr:I\P" ,-
_,'tIPll"
..'lIV
-
RI (){'I(II\I"
YEB ""
_lJ. TI1IN
NAiliNG
I t..1 "
.v SHEA TyiNG
ID AI ()('l(llJf'
'II V
,t"VI'CTlt..1 ~
n1l!V
-
SHIM
REQUIP BELOW
lJ~ :-
;---- ~II':/ //7
I !
~I
T
'7
-l!r I r 1'1' llr
I llr , r -
llr
i
I
I
~j
~ ! f 1-
UCAl f
L FLdOR B 'AU~
P~~T 25 Kip .; ~
LOfD ~ TIME I
I I
....,~~
I ~/' =
a.o.c.
TYP*
Iff ~ I ,..
1 f f f tl
//
,/'
//
//
,/
1//
///
r ~
.I ! r /
II [L:/! ...--
I ~. .- - INS~ . . . . -
I r I J .;lurt'UKT ~;-~U~::. ~~~
I_L- _ [/ ....1 PS
L _....--- ~.~ 1'/1
J ",:,/,' '---1 "I
I /1 ~_ / /~ _ ~ r
I ~1 "I//~ ~i
, I ; 2 --------t - -
/ II [I V : 1
./~.~~... _IlL II
~//~n~~~-~+l
1~8 I~-~
i I 1_ ---tf-U
~ 1
.__, _ f.
S1EEl ~
~ --
l \\\\\\\1\\ ,I
C! ()<::IIPL l ,::;#',\\ ...,,~.. I
.... ,.- - ~ u.. :::''' ,,~ ;.
jnr:,A TIiING RE* /: ,:~~~ ..
* " '" :41 ~l~
RI n....itlur. /~, ..33331 ~i~j
"" 0vri1~ \~. C~p?..$if
I '~~""""t:~~~~'
~. \.. '/111/. A\..'\.. \\\\\. )
. ~~~ "- "IIIII/mlll\\\\\\\ _
(-
~
~~-
~
I 1. 000
t-~
r-----
__I
~
420 T 0 I --..J
1~-.1 JI
- ~
I
:::; ~
t-
J
-
-
-
-
t
J
IF
"'-1 J
r I I
I II I
-r [111 I I
II I II
,I I I II
I I II ;,
lt~
~
~
=--
I
= 1t
_ RI ()Cl(!L~G BETWEEN
\lVI::> I" () \ IC'"l ,-..... "I
__ .Il...'\
1/ ~Iv
I==-==---=I~
--~-
-~
--
,... fill ._,
_, [VII ''U'::;' ~N
----
I
n. -. ---
\ I \:1\..1 r.J\
RE:
~, ~ II
,-
I
~ ~s;~GTH
=---- 1-'
==::::::::::=:-~ (i
- ~ ,_.'~ ,:
--~--~ -----
I
-
I-~~--'--~
~~__ vv l
I-~~'---~'--'-
1. ~- I--~~
~ DEVE~? p: ~
PERMiTTED __uPMENT I f:'tJTGH.
IREBAR MARK
U.a40-!.C! ., "
I - 'to, ........
_ nl='~I~M A
~-=-~ ~,.r _ _
t---
~
I I
IETER- 1<
-
NtuI
I
#1
1-
U..
60 SI
~
t
~
,-,~-
1'-.
)
--
~-
~
kl
~
--
.,.- ...
I --
if"'IIi ... ,-
r:n.J11 111\1(">
_..... " " '\7
'/1
---
-
I~_~)
-
..-
(
~l
J
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING INSPECTION LINE - (303-234-5933)
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80033 - (303-235-2855)
Building Permit Number:
15869
Date: 7/15/2003
Property Owner: RICHARD STRAYER
Property Address: 3415 KENDALL ST
Contractor License No. : 21171
Company: Porter Builders, Inc,
Phone: 238-2849
Phone: 421-9323
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that J have read and agree to abide by all conditions printed on this
application. and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat Ridge ordinances. for work under this permit.
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
$155,000,00
$1,692,35
$1,100.03
$1,860.00
$4,652,38
Total:
DATE 7-1:>-0)
7.. /'(.. (- c;<f';tJse :
(OWNER)(CONTRACTOR) SIGNED
0-<' r
Description:
ROOM ADDITION, CARPORT, FAMILY ROOM, BEDROOM BATH & KITCHEN REMODEL.
BUILDING DEPARTMENT USE ONLY
SIC: Sq. Ft. :
6/30/03. CARPORT IN-LINE WI NON-CONFORMING FRONT YARD
SETBACK.
Zonln,(CQiiP1ieOts;
Approval: MA
Zoning: R-2
".....'.. '...'..". .,..:..:. .:. "-':."ijl!.H;~::
l3uildil1Q'comm'~l:Its:
Approval: OM
'PubJj9~Worl5s C:ominiilts:
Approval:
Occupancy: Walls:
OK PER REOLlNES. 7/15/03
Roof:
Stories:
Electrical License No : 19506
Company :SECHLER ELECTRIC
CO
Expiration Date: 2/28/2005
Approval: OK/KS
Plumbing License No : 18723
Company :GPS Plumbing & Heating,
Inc,
Expiration Date: 8/31/2003
Approval: OK/KS
Residential Units:
Mechanical License No :
Company:
Expiration Date:
Approval:
This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the Slale of Colorado and to the Zoning
Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City,
This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a period of 120 days.
If this penni! expires, a new permit may be acquired for a fee of one.half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceediing with successive phases of the job.
The a:mce of a p rmil or the. approval of drawing' and ,pecmcaUon, ,hall no' be con,'"ed 'A be a perma for, nor an appro,,' of, any v;olaUon of the
isi . Cling codes or any other ordinance, law, rule or regulation.
. . . .
(1)
(2)
(3)
(4)
(5)
(6)
Inspector
Please sign Terms and Conditions on reverse side of page.
;' j
BUILDING PERMIT
For inspection this permit must be posted
on the site and visible from the street
TERMS AND CONDITIONS
As applicant for a building permit in the City of Wheat Ridge, I do hereby agree to the terms and
conditions set forth below for the issuance of a Certificate of Occupancy in connection with this
building permit. The issuance of a Certificate of Occupancy requires:
1) The completion of all required landscaping and related site improvements, Inspections
are performed by the Planning and Zoning Division,
2) The completion of site drainage/grading requirements per the approved site grading
plan and/or final drainage report and plan, if such report and plan is applicable, For all
residential and nonresidential projects with an approved final drainage report and plan, a
letter of certification is required from the civil engineer of record, Inspection are performed
by the Public Works Department.
3) The completion and acceptance by the City of Wheat Ridge of all required public
improvements, or a Development Covenant or cash escrow may be required in lieu of
construction, as determined by the Public Works Department. The Public Works
Department performs public improvements inspections.
4) The completion and approval of a Certificate of Occupancy Application form and final
inspections. Inspections are performed by the Building Division.
All the above items must be completed and approved by Planning and Zoning, Building and
Public Works before a Certificate of Occupancy is issued. Final Inspection by the Building
Division does not constitute authorization of a Certificate of Occupancy nor permission for
occupancy. Occupancy of the structure is not permitted until the Certificate of Occupancy
is issued. (Uniform Building Code, Section 109)
The City is not responsible for any real estate closings or other agreements concerning the
property which may be affected by failure to complete the above items and obtain a Certificate of
Occupancy.
I have read, understand and agree to the foregoing terms and conditions. I have received a copy
of the application for Certificate of Occupancy.
Name (please print) Va~; PlJu+-er
Signature: /"'~ /\::::>
I
Date:
7-tr-o J
,
~' .H[4r ..
:::~ \\,~
v M
('OLOR:.,<::F:I
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Al'PUCA TlON
Building Permit Number:
Date:
Property Owner:
Property Address:
Contractor License No.:
Company:
Sfr"1~r
~t""ql > r.
Wl......f-n.l~.t,
l< Il--~rr.(
l,f/>"
.:7\\"t\
p~ rhr 'S...tt'lr ("(
Phone: "], 0 S -2-"$ i'- Z-fi"l-'?
'Ho ~y (~ v'j.f/
?(f!3---tZ 1-1 t 1- "3
cd(
Phone:
OW~[RlCO:'\TRACTOR SIG:"iA fi'RE OF Vl"iDERSTA~DI~G Ar-;D AGREB,1E!"iT
1 hereby certify that the setback distances proposed by this permit application afe accurate,
and do nOI ,';olaIe applicable ordinances, rules or regulations of the City of Wheat Ridge or
coycnants, easements or restrictions of record; that all measurements shov.n, and allegations
made are accurate; that I have read and agr~ to abide by all conditions printed on this
application and that 1 assume full responsibility fOf compliance \\ilh the 'Wheal Ridge
Building Code (U,B,C) and all other applicable 'Nheat Ridge Ordinances, for work under
this permit
Construction Value:S / s-SiOt:?O
Permit Fee:S
Plan Review Fee:$E>-
Use Tax:$
Total:S
,0\\ ?\ER)(COSTRACTOR): SlGNED
DATE
6-'2.6-0~
~--U-03
DESCRIPTlOl":
~
0#1 v,1 PlPrr'(r
12oovv>. Ado/, Ht) VI, (Yq r p"" +,
tJd.<.f", rz~""'t7.1q(
(OV"~ER)\CO:'\IRACTOR): PR.I!'oIED
DATE
h,....I'1 Q.."....
BUILDING COMMENTS: {~ r...er k-tfl (/--n-I s
Approval:
'J /J>-t'3
tp
PUIIUC WORKS COMMENTS:
Approval:
Occupancy:
Walls:
Roof:
Stories:
i~.(-'"
Electrical License No: \ '7') 0 to
Company: ,>,<c,J, L- r Flccc_.
Plumbing License.No: 1'2'.-]23
Company: c':..:,,~ I>~; ? \ \,,~ ,V,- b it"-,'}
'.
Expiration Date:
Approval:
Expiration Date:
Approval:
Residential Units:
Mechanical License NO.:
Company: rCf \ r. ,\ <. \'\~~'j
Expiration Date:
Approval:
(I) This pennil .....as issued in accordance with the PfO\1StonS sa forth in your application and is subjecllO the laws of the Stale: orColondo and to tM Zoning
Regulations and Building Codes of\\'beat Rldge, Colorado or any other applKabk ordinances o{the Ciry.
(2) This pc-nnit shallexpirc ir(A) the work authorized is not commenced within sil\.t), (60) days from i~ue dale or (B) the buikling lulhorized is sl.lSpCnded or
abandoned for' period of 120 days.
(3) If chis permit expires, I new permit may be acquired {or I (<< o{ one-half the amounl nonnally requimS. provided no changes h~\'(: been or ",ill be lll-J<de
in the original plans .and specifications aod any suspension or .b&Ddonmenl has not v.ceeded one (I) year, If changes have been or if suspension or
abandoameat o.cceds ooc (I) yeas. fd fees shan be pliid {or I oew penniL
(4) No won o{an}' manner maD be done 1bat wm chanJC Ibc natural fkrw ofwatef causinl a drainaJC problem.
(5) ConttaClOf shaD DOrity Ihc BuikliD& J.nspcc1lOr twenty-row (24) boun in advance for an inspections and shall recei\'e written approval 0fI inspection cud
before pnxecdiRI -.vidt successive phases of the job.
(6) The iuu.ance of. permit or the approval of dIawiap UId sp<<ifKations shall not be constrUed to be I pennit for, n()I' an appro\...1 of. an). violation of the
~~~----_.-
Chief Build' pector
M
J//
. 1/ /'
/ .' '/
/ /
/ /,
/
:/ I
LL
I \,
! ;\!
;'1
: i
"
"
~;' J
! I
. Y'r
I
I
~/'7"
// /'5/
-To
QIcdifirutc af c3JmFrobemcnt ~urbclI
. W ffi. H. Burgwin 8: Associates, INC.
Consulting Engineers
~a_ 49605
STRAYER
Revised 10/15/6
723 DELAWARE ST AREI., CODE 303. 222.7g3~
DENVER. COLOR..,OO 80204
F /?OC9 /hbO'.-;>.rC7/~ LJ,k-->
/.5 . ~.
. c-~~e~~r' --~.. ...1ir-
'<1 . \,
'\0& ~
,"
/2c7~
-..
3/
~
~
....
"':
88,2~
c-
""T
~~-
- .]'
32.S
./ 5/07
L!?".-/cC .
\')
o
~
I
,
i
--11
, ,
\1
I'
,
"
I\;
\') ,e~5/cT~/?C"~
"J 8'
\i: 4' 3<7/5
I
'\) I
Ie, ,
I
~. <---'by::
I
.9'
~ I"
/"'-:.:5 .j
I I. ",I
I c, Cby ,~ar1" I
, 1,\ I
'~ I
~ - - - ~, c c r . 7;:/.cr 8
LC::_ (\ "'>I~'r I ....J
"
---- C', ----r- --
. G...,.~:':' ~ l~',.'i'/
1
--3'- EC::U-=-~.-;;>r
or'
4dd/7'>0/7
/'S/O/' y~
.+' 3<:;J'c)/
.5C/.c7O'/Y~~ ./M
Scale
'"
l
ZZ'
I'
--------1
--'-- _ --J
'\
(',
'"
t
iJ)
~
,~}
\j
~
~
/PZO'
SUBMITTED FOR:
PORTER BUILDER, INC.
3415 KENDALL STREET
JEFFERSON COUNTY, COLORADO
SOIL INVESTIGATION REpORT
JUNE 12, 2003
PROJECT # 031-0434
SUBMITTED By:
PAULR. BRYANT, P.E.
COLORADO ENGINEERING
& GEOTECHNICAL GROUP, INC.
2931 NORTH U.S. HIGHWAY 85
CASTLE ROCK, COLORADO 80109
303-688-9475
TABLE OF CONTENTS
AGREEMENT OF PURPOSE AND DISCLAIMER
PAGE 2
INTRODUCTION
PAGE 2
FINDINGS
PAGE 2
RECOMMENDATIONS
PAGE 3
SPECIAL CONSTRUCTION
PAGE 3
FOUNDATION DESIGN
PAGE 3
FIELD INVESTIGATION PROCEDURE
PAGE 3
EXISTING SITE CONDITIONS AND WEATHER
PAGE 4
SUBSURFACE DRAINAGE
PAGE 4
SURFACE DRAINAGE
PAGE 4
BACKFILL
PAGE 4
CONCRETE
PAGE 5
EXTERIOR AND INTERIOR CONCRETE SLABS
PAGE 5
RADON
PAGE 6
OPEN-HOLE OBSERVATION
PAGE 6
COMPACTION
PAGE 6
CONCLUSIONS
PAGE 7
LIMITATIONS
PAGE 8
LOCATION MAP
FIGURE 1
VICINITY MAP
FIGURE lA
LOGS OF TEST HOLES
FIGURE 2
SUMMARY OF LABORATORY TESTING
TABLE 1
SWElL-CONSOLIDATION TESTS
FIGURE 3
FRAMING DETAIL
FIGURE 4
DECORATIVE GRAVEL OR BARK
FIGURE 5
DETAILS OF FOUNDATION DRAIN
CONTINUOUS FOOTINGS
FIGURE 6
DETAJLS OF FOUNDATION DRAIN
WALL ON GROUND
FIGURE 7
AGREEMENT OF PURPOSE AND DISCLAIMER
The parties specifically agree and contract that the purpose of this soil investigation is to test, analyze,
and report on the condition of the soils encountered only as these tests pertain to the smtable design
and construction of an appropriate foundation for the proposed building and/or residences to
determine the load bearing capacities of the soil. The parties specifically agree that Colorado Engineering and
Geotechnical Group, Inc. has not been retained nor will they render an opinion concerning environmental issues, hazardous
waste or any other known or unknown conditions that may be present on this site.
INTRODUCTION:
This report summarizes the results of data obtained during a soils test of 3415 Kendall Street, Jefferson
County, Colorado. Investigation occmred on May 30, 2003 and was performed in undisturbed soil in
accordance with ASTM 1586-99. The purpose of the investigation was to reveal the engineering
properties for foundation purposes for the proposed construction of a residential addition with a
basement. The site is currendy occupied, Other aspects relating to the proposed construction are
presented.
A component document to this plan will be an Open Hole Report that will be produced after the Open
Hole Inspection, which is not billed with this report, The purpose of the Open Hole Report is to
determine whether any significant variation from this report and the observed condition exists and
whether the foundation design will require modification.
FINDINGS:
The soil encountered in test hole one consisted of brown, fine to medium-grained clayey sand with
moderate density to the ten foot depth (Unified Soil Classification System symbol SC), From the ten
foot to the sixteen foot depth, the soil consisted of brown, fine to medium-grained silty clay with
moderate/high density (Unified Soil Classification System symbol CL). From the sixteen foot to the
nineteen foot depth, the soil consisted of brown, fine to medium-grained clayey silt with moderate
density, Potential for foundation movement is low.
Attached are graphic summaries of the boring logs of the field conditions encountered and a summary
of laboratory testing results. It should be noted that the soil descriptions shown on the boring logs are
based on the geologist's visual classification of the samples in the field at the depths indicated, Actual
subsmface soil conditions may vary between samples and location tested.
Groundwater was not encountered in the test boring at the time of this investigation. The presence of
shallow bedrock beneath smficial soils is favorable for the formation of "perched" groundwater. The
depth and occmrence of groundwater can vary over time depending on hydrologic conditions such as
precipitation, smface drainage, irrigation, and other conditions not apparent at the time of this report.
Project #: 031-0434
www.coloradoenpineennpI!TOuD.com
Page 2 of8
RECOMMENDATIONS:
A satisfactory type of foundation system will bear on the undisturbed natural soil (i.e. footings, wall on
grade). The foundation shall be designed for a maxim\l1ll soil bearing pressure of 2,000 psf for
elements resting on undisturbed soil, The active case equivalent fluid pressure is 35 pef, All loose and
disturbed soil shall be removed before placing of the concrete for the foundation. The bottom of the
foundation shall be a minim\l1ll of three feet below final grade for frost protection and below any
organic material. Settlement at this site may be up to one inch but will most likely be less than one-half
inch, Soil expansion at this site may be as much as one inch in some areas but will probably be less than
half of this amount. No foundation wall shall exceed twenty-five feet in length without utilizing
counterforts or buttresses unless otherwise designed by the foundation engineer
SPECIAL CONSTRUCTION:
Provided the excavation does not exceed ten feet below existing grade, the preferred foundation design
will consist of a reinforced concrete stem wall resting on a concrete footer of a size determined by the
foundation engineer. Depth of foundation elements shall be determined by the foundation engineer,
but should be at least as deep as the minim\l1ll depth required by the governing building authority.
Concrete slabs shall be free floating and isolated from load-bearing elements. Partition walls, utility and
HV AC connections shall be capable of a minim\l1ll of 1-1/2 inches of movement of the foundation
and slab, An attached detail sheet diagrams a typical floating wall design, The soil bearing strength above is
subject to change based on observations made at the open-hole inspection. Owners shall be made aware of the
contents of this report and the fact that water accumulation around foundation elements is the primary cause of
foundation distress.
FOUNDATION DESIGN:
This report is not a foundation design. The foundation design engineer will determine the exact
configuration of foundation elements, to include footer (if any) width and thickness, wall thickness and
height, pad and pier sizes and reinforcement schedules. However, the foundation should be designed
for a ten-foot free span.
This report does not address general hillside stability, landslide potentia~ or other natural hazards.
Several areas of the Colorado Front Range have known geologic hazards associated with them. We
recommend that readers of this report further educate themselves as to the existence of geologic
hazards on or around their specific property of interest. Colorado Engineering can assist in the
development of site specific assessments of Geologic hazards. The Colorado Geologic Survey
{www.dnr.state.co.us/geosurvey or 303-866-2611} is a good source for publications (maps, reports,
etc.) dealing with specific geologic issues and/or issues related to specific geographic areas.
FIELD INVESTIGATION PROCEDURE:
Exploratory borings were advanced using a four-inch nominal diameter, truck-mounted continuous-
flight auger. The approximate boring locations are indicated on the attached site diagram and were
established in the field by pacing and m"asl'ong angles from identifiable site references. The builder
Project #: 031-0434
www.coloradoenflineerinr/!!rouD.com
Page 3 of8
t\
@
@
@
TH-1 -$-
LAWN
8
t\
THZ -$-
DECK
t'
1Z'ACCESS
N.~HOUSE CORNER
HOUSE
LAWN
CHAIN LINK FENCE
~
o 5 10
GRAPHIC sCALE IN FEET
SCALE: 1- = 10.
SITE PLAN
OWNER/BUILDER, Porter Builder, Inc. . .Jobtl 031-0434
JOB ADDRESS: 3415 Kendell St., .Jelfer.oon COunty ..
....
DRIVEWAY
:lII:
m
Z
c.
)>
r-
r-
tI)
...
::Ill
m
m
...
N.W. House Comer TH-1
lH-1 TH-2
TO DlaTANC:I! BeARING
..9W
51?E
19'
22"
CASTLE ROCK OFFICE
2931 N. HWY 85
CASTLE ROCK, CO 80109
(303) 688-9475
FIGURE 1
designated the location for exploration. At depths determined by the supervising geologist, samples
were obtained by means of a two-inch diameter split-spoon sampler, advanced by a 140-pound drop-
hammer falling a distance of 30 inches, in general compliance with ASTM D-1586. The number of
hammer blows required to advance the sampler provides an indication of the in-situ relative density of
the soil, and in combination with the laboratory analysis of the soil, provides data required for
derivation of the engineering properties sought by this exploration.
EXISTING SITE CONDITIONS AND WEATHER:
The general topography around the site of this investigation is relatively flat. Vegetation consists of
native grasses, weeds, trees and pines. Weather was clear and hot at the time of the investigation,
Elevation was at 5,300 feet.
SUBSURFACE DRAINAGE:
Foundation drain requirements shall be determined at the open-hole observation; however, drains
around any below-grade useable space, including crawl spaces, should be anticipated. See the attached
detail sheet,
SURFACE DRAINAGE:
The excavation shall be protected from surface runoff and excess precipitation during construction.
After backfilling, the soil around the foundation shall be graded away from the structure at a minimum
slope of six inches over ten feet. Gutters and downspouts shall be installed to carry water across the
area disturbed by construction. Areas that settle shall be backfilled to prevent ponding of water. No
vegetation requiring irrigation shall be installed within five feet of the foundation. Water from uphill
shall be diverted around the structure, The future owners are cautioned against the installation of a
lawn sprinkler system within 5 feet of the foundation walls. If a sprinkler system is installed, the
sprinkler heads should be placed so that water spray from the heads under full pressure does not fall
within five feet of the foundation walls. Lawn irrigation should be controlled to prevent excess wetting
of subsurface soils. Lawn, flowers, shrubs, and other plantings within five feet of the foundation walls
should be hand watered and this watering should be minimized. If a drip irrigation system is used, one
should limit the amount of water to sustain the plantings. One is also advised that any irrigation line
can leak and/or break, releasing excessive amounts of water near foundations and can cause damage to
slabs and foundation walls.
BACKFILL:
Any soil disturbed adjacent to bearing foundation components shall be re-compacted to a minimum of
85% Standard Proctor Density. Soil supporting concrete slabs shall be compacted to 95% Standard
Proctor Density. Mechanical compaction methods shall be utilized; water-flooding techniques are
prohibited, See Compaction Section for more information regarding compaction requirements and
techniques.
Project #: 031-0434
www.coloradoenpineerlnl!r!roul1.com
Page4of8
CONCRETE:
All concrete shall be Type II, Sulfate Resistive, with 28-day strength requirements determined by the
foundation design engineer.
EXTERIOR AND INTERIOR CONCRETE SLABS:
Excess moisture in the soil and improper compaction under slabs will increase the possibility of slab
heave, settlement and cracking. The builder and future owners should be aware of and understand that
there is a definite risk of future damage with any slab-on-grade construction. If floor movement due
to expansive soils is not acceptable, finished room floor areas should be supported on wooden
or steel joists over a crawl space area, or on a reinforced concrete slab. If the builder and future
owners are willing to accept the definite risk of some damage due to concrete floor slab movement, the
following recommended details will help prevent, but not guarantee, wetting of the soils underneath the
slabs and minimize damage when wetting of the soil does occur.
Do not place a gravel layer beneath the concrete slab, unless specified by the foundation engineer. The
slab should be placed on the undisturbed native soils, or well-compacted filL
Interior concrete slabs shall be isolated from the foundation, utility lines and non-bearing partition
walls. Separate the slab from all load bearing members and utility lines of at least one-half inch to allow
for independent movement of the slab. Provide a positive control or slip joint at the construction joint
between the slab and foundation walls
Slabs shall have control joints at approximately ten feet on center each way to lessen the possibility of
random cracking. These control joints may be installed as construction joints, saw cuts and! or scoring
of the slabs. Cuts should be tnade at least 'I. the total thickness of the slab. A good quality concrete
sealant should be installed in these joints to prevent surface discharges of water from penetrating slab
subgrades.
A minimum void or clear space of one and a half inches should be provided at the bottom of all
non-bearing partitions and furring strips placed over the concrete slabs (see Floating Wall
Detail). One should also provide a one-half inch space at the bottom of all door jambs to allow
for limited movement of the floor slab. The owner is hereby notified that it is there
responsibility to maintain these void spaces.
In the event a hot water heating system is used, the pipe should not be placed beneath the
concrete floor slab, In the event a forced air furnace is used, a two-inch collapsible connection
should be provided between the furnace and the heat ducts.
The soils that will support the concrete slabs should be kept moist during construction by
occasionally sprinkling water and especially a day or two prior to pouring of the slab. TIlls
procedure will help maintain the moisture content of the underlying soil.
In addition to the above recommendations, another means with which to reduce the risk of
movement and cracking to slab-on-grade construction would be to over-excavate the below
Project #: 031-0434
www.c0/oradoen!!illeerin1!!!roUD.com
Page 5 of8
slab soil two or more feet, replace with compacted structural fill material, pour the concrete slab
six inches thick with a reinforcing mat of #4/60 bars at 18 inches each way.
RADON:
There is not believed to be any unusual hazard from naturally occurring sources of radioactivity at the
site. However, most counties in Colorado have average radon levels (measured in homes) above the
u.s. EP A recommended "action lever' of 4 picoCuries per liter of air (PCi/I). For instance, Teller
County averages 31.94 pCi/I, Park County averages 8.28 pCi/I, EI Paso County averages 4.73 pei/I,
and Douglas County averages 7.53 pCi/1. Results of a 1987-1988 EPA-supported radon srody for
Colorado indicate that the granitic rocks, in particular, generally have elevated levels of uranium. These
rocks have the potential of producing higher than average radon gas levels in homes. Providing
increased ventilation of basements and crawl spaces and sealing of joints can mitigate build-ups of
radon gas, This mitigation is best implemented during the design and construction phases of
residences. The Colorado Geologic Survey {www.dnr.state.co.us/geosurvey} and the U.S. EPA
{www.epa.gov/iaq/radon} are both good sources for additional information regarding radon.
OPEN-HOLE OBSERVATION:
It is necessary to assume the soil in the surrounding area will be similar to that which was observed in
this initial investigation, However, variations across the test borings and site can and do occur,
Therefore, it is required that a qualified soil engineer inspect the completed foundation excavation prior to the placement of
any foundation component to determine whether any significant variation from this report exists and whether the
foundation design will require modification. Please contact this office a minimum of 24 hours in advance to schedule a
representative to observe the completed excavation. The open-hole observation is not included as part of the soil report and
is subject to an inspection fte. Failure to obtain this required inspection prior to placement of foundation
elements renders this report and it's recommendations null and void,
COMPACTION:
If compaction of the native or borrow soils is required, it is highly recommended that you pick up an
informative brochure provided at any Colorado Engineering and Geotechnical Group, Inc. office. In
general, to compact clayey or silty materials:
Placing Fill.' No brush, sod, frozen materuu, or other perishable or unsuitable material, or stones
of four inches or greater in maximum dimension shall be placed in the fill. The distribution of
the material on the fill shall be such as to avoid the formation of lenses, or layers, of material
differing substantially in characteristics from the surrounding material. The materials shall be
delivered to the backfill surface at a uniform rate, and in such quantity as to permit a
satisfactory construction procedure. Unnecessary concentration of travel tending to cause ruts
and other hollows more than six inches in depth, shall be regarded and compacted. After
dumping of fill material on backfill surfaces, the material shall be spread by approved methods
in approximately 6 inches compacted thickness.
Moisture Control.' The material in each layer shall be compacted by rolling and shall contain the
optimum moisture required for maximum compaction. as nearly as practicable and as
Project #: 031-0434
www.coloradoenp;neerinf!1!rouD.com
Page 6 of8
detennined by the soils engineer. The moisture content shall be uniform throughout the layers,
The contractor may be required to add the necessary moisture to the backfill material in the
borrow area, If in the opinion of the soils engineer, it is not possible to obtain moisture content
by adding water on the fill surface,
Compaction: When the moisture content and condition of each spread layer is satisfactory, it
shall be compacted by a method approved by the soils engineer to 90% ASTM D698 (Standard
Proctor Density) for slab areas, and 100% ASTM D698 for footing and/or pad areas, A
Standard Proctor test shall be performed for each typical fill material and frequent tests of the
density of the fill must be taken, Normally, eight passes of a sheepsfoot roller loaded to 4,000
pounds per lineal foot on a six inch soil layer is sufficient to achieve 90% ASTM D698.
In general, to compact cohesionless free-draining materials: Note: The above guidelines also apply
When compacting cohesionless free-draining materia1s such as sands and gravel, the materials
shall be deposited in layers and compacted by treads of a crawler type tractor, surface of internal
vibrators, smooth or pneumatic rollers, hand or power tampers, or by any other means
approved by the soils engineer. The thickness of the horizontal layer after compaction shall not
exceed 6 inches compacted thickness if compaction is performed by tractor treads, surface
vibrators or similar equipment, or not more than penetrating length of the vibrator head if
compaction is performed by internal vibrators. The material may not be ponded or flooded to
aid in the compaction only if free draining materials underlies new fill unless specifically
recommended by the Engineer. When the moisture content and condition of each spread layer
is satisfactory, it shall be compacted by a method approved by the soils engineer to 90% ASTM
D1557 (Modified Proctor Density) for slab areas, and 95% ASTM D1557 for footing and/or
pad areas.
If compaction testing is to be performed by Colorado Engineering & Geotechnical Group, Ine. we will
require a Proctor Curve, Standard or Modified (which ever is appropriate for the material tested), from
an approved testing facility. Colorado Engineering & Geotechnical Group, Inc., if requested, will
perform this test(s) for you, provided a sample of the material(s), 5-gallon bucket(s) full, be supplied to
Colorado Engineering & Geotechnical Group, Inc. a minimum of 72 hrs prior to testing. The
sample(s) will be used to detennine the maximum proctor density and optimum moisture content for
that representative sample. Additional charges will be incurred for each sample tested and for
field compaction testing operations if required.
CONCLUSIONS:
This report is valid only for the me of the client listed for the type of constrnction listed above. Use by
any other is prohibited, as is the use for other types of constrnction without the express, written
pennission of this office. Property owners and builders are reminded that water accumulation around
foundation elements is a primary cause of strnctural distress in homes, Foundation movement under
any condition can be minimized by maintaining a stable moisture content of the soil
supporting the foundation. Surface drainage is paramount to minimizing the potential for water to
penetrate backfill to the level of the foundation. If water penetrates through to the soil supporting the
foundation, movement is likely. Any movement that does occur should be less than 1".
Project #: 031-0434
www.coloradoenpineerinf!l!rouD.com
Page 7 of8
LIMITATIONS:
This report and its recommendations do not apply to any other site other than the one described herein
and are predicated on the asswnption that the actual soil conditions do not deviate in any significant
way from those described in this report. In the event that any variations or undesirable conditions are
detected during the construction phase or if the proposed construction varies from that planned as of
this report date, the owner shall immediately notify Colorado Engineering and Geotechnical Group,
Inc., so that supplemental recommendations can be provided, if needed.
Project #: 031-0434
www.coloradoenllineerinf!llrOUD.COm
Page 8 of8
031-0434
ADDREss:
3415 KENDALL STREET
JEFFERSON COUNTY
FIGURE lA
OJ)
s::=
.-
~
(])
(])
s::= ~
......
.- 0
OJ)~
S::=ti
~~
4-<
o 0
"'dgf
C\;S....:l
~
o
.....-I
o
U
c:
~
iii
~
Q)
:;:
III
Q)
C.
E
III
III
'5
III
..c:
u
E
:;:
'OQ)
e: >
~ .C
0-'0
0.8
'V-00
~Q)Q)
Ctli.~ .s:;,
......:]g
o 0"._
UJ~N
:;:1Il~
o .- I....
:a~..9:!
<o..c: 0-
NuE
e: III
co .- rn
..c:O~
-MQ)
UJ 0) Q)
2.E E
co = co
.g~u
"gl....c
,- Q) u
NEe:
-- E "'j'
(DCON
N..c:lIl
""
M
""
9
...
M
o
0::
W
III
:E
::J
Z
III
o
..,
c:
~
al
-
III
..c: '
_e:
O-~
Q) III
0_
N
o
c:
J:
o
iii
u
c:
'"
(f)
>.
Q)
>.
'"
C3
,
..
en
>.
Q)
>.
'"
C3
>.
'"
C3
f;-
en
L
~
11_-;:;:;:;:;:;
',',',',',',
."""
""'"
(f)
W
I-
o
Z
~l ~l
L()
o
~
""."".
"""-,,
"""""
."."".
>~,~,~.:'~,>>:': "C"""
,',',',',',',',',',
,',',',',',',',',',
L()
...
o
N
L()
N
199 d U1 qldga
o
C')
FIGURE 2
Cj
~
E-<
r:/l
~
E-<
~
o
E-<
~
o
~
....:l
~
o
~
~
~
r:/l
"'"
M
"'"
o
I
......
M
o
~
!
Z
0
...... Q Q
E-< ~ ~ ><
I'l.; ~
~ r/J r/J ....:i
U >< >< U
r/J ~ ~ ><
r.Il f-<
Q ~ j ....:i
......
....:i ....:i r/J
...... U U
0
r/J
~~r/J N N N
o~~ ...... ...... ......
I'l.; 3 ~ ~ ~
\0 \0 0
N N N
o ~
"'"
......
0
0
N
og; "'" M 00
~r.Il t-- N V)
r/J......
r/Jr/J
<t:
I'l.;
~~~ N 00 0
E-< r/J C N ......
<t:o
Z;:E
::r::r-.
E-<E-<
I'l.;"" M 00 M
r.Ilr.Il ......
QC
r.Il
....:i .
00 ...... ...... ......
::r::Z
~
o
....,
TABLE 1
en
"
1::::
~ ~
" 0
8<;;
- ~
"'0
-g ~
~ ~
'"
l ~
<ne.
v.
/
V
- 7.-
V yo
v v
~
'0
"
'0"
~a.
_ E
" ..
o;<n
3:,S
.
I.OVMC\l..... O.....NM V 1.0
I I I I I
n8MS JO uOI~epllosuo=>
JO (%) ~Ue~Jecl
o
o
o
o
o
.....
0
0
0 ....
0 - ....
..... Ql ....
~'i'
....1...
J::....
_0
a...
- Qla:
... 'Ow
f/l 1;j1ll
Q. ...1::2
-
'0 '11:::1
os QlZ
0 -Ill
..J ,go
w....
Ql
- '#.
E "'I
0 e",
- c:
0 'l:J
0 C ~
'" c:
..... III 0
U
ell l!!
'" ::>
(3 -
<n
- '0
0::;;
Ql-
- '"
o.~
E.a
'" '"
Cf)Z
o
o
.....
FIGURE 3
C>
c
"E~
~ ;
c 0
0-
u "
~ =>
"'0
-g ~
=> =>
~= ill
~
0.
I'
J
/
./' v. \
"./' V \
Ik" ~
'0
"
:g~
<(0.
_ E
" ..
a; en
;;:.s
.
U') """ ('I') N ..- 0 ..- C\I ('I') """ LO
I I I I I
118MS JO uOIJepllosuo:)
JO (0/0) JU8:>J8d
o
o
o
o
o
......
o
o
o
o
......
o
o
o
......
o
o
..-
Q)~
J!!'"
COI'i'
;M
0.0
Q) ..
_ 1j lI::
UI - W
Co I'll III
- '1""15
'II::J
~z
,gill
-0
en....
2
E~
~ col
.... -
"C c
c2
III c
tIl 0
()
ell Q)
~
III :J
- -
o .!!l
.... 0
o::a;
~m
o.~
E.a
I'll I'll
tIlZ
~
"C
III
o
...J
FIGURE 3
0>
c:
1: I:
.. Gl
" 3
c: 0
8~
- "
Gl",
1" I!!
" "
= '"
Gl '"
3 I!!
l1)0.
i
I
T
/ .
\
/ \
JC ~
'll
:g..9:!
0(0.
_ E
Gl ..
1;;l1)
5:S
.
1.0..,-(")(\1.....0......"1('1')..,-1.0
I I I I I
118MS JO uonepllosuoO
jO (Yo) ~ue:)Jed
o
o
o
o
o
......
0
0
0 "<t
0 '"
...... _"<t
ale;>
~....
"'I'"
'r'"~
~ .<::D::
- aW
:q, allD
u::!:
- 0;:>
" ....IZ
ClI
0 'll:lD
oJ alO
0-'
.<::
(j)~
$ 01
0 E:
0 e <::
0 ....$
f
...... l'll 0
-u
() al
~
- "
.- -
lIJ .!!1
.... 0
O::!;
al-
- '"
c.~
E2
'" '"
cnz
o
o
......
,
FIGURE 3
ft Geotechllictll (Jroup, Inc.
Drill 3/8" dia. hole in top
base plate and use 60 penny
nails at about 3'-0" c.c. to
stabilize frame wall, Drive
large nail into lower base
plate
2"x4" stud wall
secured from above
by metal straps or nailing
,1/2" drywall nailed
to studs, only
.' .:' 1 1/2" space to allow
[Y:. , fO,rindependeni,
: movement of the
. floor slab
, ,
II
.V
"
,,'
o
O@ .. .:.::'
~ Concrete floor slab
l/2"xl" nailing
strip to hold
base board in
place
','
.~l'
." <t . :':
Q
FRAMING DETAIL
Non-bearing wall on concrete floor
slab,over'expansive clay soil
, '
','
2"x4" base plate
secured with 3"
concrete nails or
ramset studs
FIGURE 4
ft Geote(hnl(tll Group. 111(.
Provide a minimum slope of 10%
in the first 5' out from the house
Roof gutter downspout and extension
should extend beyond the gravel or
bark area. ~
Decorative gravel or
bark area.
Metal or wood edge with
weep holes or Yz" space
at the bottom to allow for
the release of water.
-- ..--- ---:~-.:..:--
--'
. .
Ground surface
~
"~(J
;~
Support for
edge strip
Plastic membrane
or Landscape fabric.
2 x 4 (2 x 6) Redwood
with 12" spike @ 4' oc
drilled hole.
PREFERRED METHOD
DECORATIVE GRAVEL OR BARK
AROUND PERIMETER OF HOUSE,
1 x 4 x 4" Redwood
@ 12" oc
Gravel over plastic or
Landscape Fabric
ALTERNATE EDGE STRIP
."...~I..
Concrete
Foundation wall
FIGURE 5
& Geole~hni~tll Group. IlIe.
~
,FOUNOA11ON WAll
)
(
. WAJERPROOFING
':".
o
.
0"9'
';""
L7
"0,
'j, .~
. .
CONCRETE SLAB
'; o.~
.. Q~'~o
POL YETHElENE
~ l'
t::)1
l
~ 2' -~.. ~ 6"~
:1L 3"OR
, . 4" OIAM. ETER PERFORATID
PlASTIC PIPE
MEMBRANE
MINIMUM DEPTH' OF
CLEJIN GRAYa, 12"
I MINIMUM SIZE n
Details of perip-heral drain ~stem
Partial w.n on Gnx.w1d Foundation Systems
SLOPE to VR'AIN 11'0,0 SUITABlE O\lnEr, 1;4" PER FOOT .
FIGURE 7
FtGeotechniclIl Group, It".
":. '-~":
INOTEj DO NOT EXCAVATE TRENCH '
, VERTICAL TO THE. FOOTING
.. ...
.,,:
THE SLORE TO THE BonOM OF
THE DRAIN PIPE SHALL EXTEND
OUT AT A 45. AHGLE WITH THE
BOTTOM,OFTHE FOOTING
WATERPROOFING
.'
BACKFILL AREA
"
. .':',
FOUNPATION
"
"
,WAI.,t;.
>
CONCRETE, 'SLAB
'PAPER ON
GRAVEL
CONCRETE. FOOTING
MINIMUM DEPTH OF CLEAN
GRAVEt, 8' INCH'ES (MIN,
SIZE 1 INCH '
, Details of Peripheral Drain System
Contiimous Footing Foundation System" ,
SLOPE TO DRAIN INTO SUITABLE OUTLET;I/4" PER FOOT
FIGURE 6
f
t
,
,
,
i
I
l
I
I
l
t
I
,
,
i:
~,-
BUILDING DEPARTMENT
(303) 235-2855
CITY OF WHEAT RIDGE
,.\
,
,
1
1
'I
* *
Correction Notice
/ / i'
k ;_, JI,-;I A " I
.,.---' .;'
<-::; /
f'
,
Job Located at
") '-IJ ';
I have this day inspected this structure and these premises and
have found the following violations of City and/or State laws gov-
erning same:
I '~;IC... ;,j;:.? /' II" /) ~,'l
I I
-/.-,}.. :,' ~ I,,'
e.' ~,- ..' f l ~-
,/1",..../,' 1/
,,.. . ".', ' ,-(t'" /" .
!
;1"" r-' ' I c,
..
I
,
/~; e
",4"
,
/, -:
';;C'
'," Lj}" 1//--1',--,,:
,,'
/1" .:" ,"
I ,":'.</''; <,~ <..- '/,
You are hereby notified to correct the foregoing violations.
When corrections have been made, call for inspection.
Date
; /.dI~/O ./
I
I
I' ~.:
,
Inspector lor Building Dept.
DO NOT REMOVE THIS TAG
FORM WR6-22
'c.'_.... ,,',~ _H.._'..l, c;_'.. .. ,..-- ~.....,-,,--.
;>
rl~~1c~'~"'~.S.:('J>:;;'.'"
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 11054
BUILDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE Date: 8/22/2000
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Property Owner:
Property Address: 3415 KENDALL ST
Contractor License No. : 207
Comp STCO ELECTRIC. INC,
OWNER/CONTRACTOR SIGN
Phone: 934-8749
Phone: 720-890-8133
1 hereby certify that the setback distances proposed by this pennit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and 8Qree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U,B.C.) and all other applicable Wheat Ridge ordinances, for work under this penni!.
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
$700.00
$29,60
$0,00
$10.50
$40.10
(OWNER)(CONTRACTOR) SIGNED
DATE
Total:
Use:
This pe sued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning
Regulations and Butldlnp' Code of Wheat Ridpe, Colorado or any other applicable ordinances of the City.
This permit shall expire If (A) the work authonzed is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a period of 120 day's.
If this permit expires, a new permIt may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or If suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours In advance for all inspections and shall receive written approval on inspection card before
proceediing with successive phases ot the lob.
The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of the building codes or any other ordinance, law, rule or regulation.
Description:
NEW 150 AMP PANEL
Approval :
Occupancy:
Elect' License No : 20724
pany :WESTCO ELECTRIC,
INC.
xpiration Date: 7/10/2001
pproval: OKlKS
(1)
(2)
(3)
(4)
(5)
(6)
BUILDING DEPARTMENT USE ONLY
SIC:
Sq. Ft:
J~
r/"t 01"'1 \~
~
Roof:
Stories:
Residential Units:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date :
Approval:
Expiration Date :
Approval :
Chief Building Inspector
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Building Permit Number: 11054
Date: 8/22/2000
Property Owner:
Property Address: 3415 KENDALL ST
Contractor License No, : 19814
Company: Westside Heating and Air Conditioning Inc
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Phone: 934-8749
Phone: 469-4507
(OWNER)(CONTRACTOR) SIGNED
DATE
Total:
$700,00
$29.60
$0,00
$10,50
$40.10
I hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit.
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
Use:
Description:
NEW 150 AMP PANEL
BUILDING DEPARTMENT USE ONLY
~
Approval:
Zoning:
SIC:
Sq. Ft :
IIIII\BlIIIIIII
Approval:
----
Approval:
Occupancy: Walls:
Roof:
Stories:
Residential Units:
Electrical License No : 20724
Company :WESTCO ELECTRIC,
INC.
Expiration Date: 7/10/2001
Approval: OKlKS
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval :
Expiration Date:
Approval:
(1)
(2)
(3)
(4)
(5)
(6)
"L\
n/'r
\
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Building Permit Number:
Date:
~_11-00
Property Owner:
Property Address:
Contractor License No, :
Company:
K'c:.~ s\eo.;A"'R...
3'-/ij- l-<erJ' LlST, Phone: 303-9 _'.?'life
lCj'ilI,/ 31./ ,f
1.\ -sid HeGTiN"tCl-Alct/.Jc
VJf!.-S1 e 0 Phone: 303, '1109-'-150 7
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
,100 00
~(j', ~~
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate
and do not violate applicable o~dj.nances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restnctlons of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that 1 assume full responsibility for compliance with the Wheat Ridge Building
Code (U Be) and all other applicable Wheat Ridge ordlnal)ces, for work under thiS permit.
(OWNER)(CONTRACTOR) SIGNED ~~ ~r Ll.QATE ~,r7 'C):}
Description: N ~ W / 50 An- f' rq PJ <2 L '
Ie. 50
'--/0/0
Total:
BUILDING DEPARTMENT USE ONLY
ZOh~~omm~
Approval:
Zoning:
BUJrdffiQt"',omments:t
Approval:
P.U6Irel'mll:Rllt~rnep~
Approval:
Occupancy: Walls:
SIC:
Sq. Ft.:
Roof:
Stories:
Residential Units:
Electrical License No: 53 <j do
Company:WestC6 [.LeC'f.I~
~.~;:;;
Plumbing License No :
Company:
Mechanical License No :
Company:
.:. -L'i!ll::lill(;[;,!,:c,
Expiration Date:
Approval:
. ~llIl\lI'I8I[ql!lI:ed,
Expiration Date:
Approval:
Expiration Date:
Approval:
l1li
.
.1. b.J.l12;.Ut.IllIJ" '. "
l4)
5)
(6)
This permit was issued in accordance with the provisions set forth in yopur application and Is subject to the laws of the State of Colorado and to tOe Zoning
Regulations and Building Code of lA'heat Ridge, Coiorado or any other applicable ordinances of the City.
This permit shall expire If (Al the work aulhonzed is nol commenced within sixty (eO) days trom issue dale or (B) the building authorized Is suspended or
abandoned for a period of 120 days. .
If this pennit expires, a new pennlt may be acquired for a lee of one-half the amount normally required, provided no changes have been or will be made In the
anginal plans and specifications and any suspension or abandonment has not exceeded one (1) year, If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit.
No work of any manner shall be done that will change the natural now of water causing a drainage problem.
Contractor shall notify the Building Inspector ~enty.four (24) hours in advance for all inspections and shall receive written approval on Inspection card before
proceediing with successive phases 01 the/'ob. ' .
The issuance of a permit or the approval 0 drawings and specificalions shall not be construed to be a pennit for, nor an approval of, any violallon of the proviSions
of the building codes or any other ordinance, law, rule or regulation.
(1)
(2)
(3)
Chief Building Inspector For Mayor
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
,
~ DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION LINE. 303-234-5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Building Permit Number: 10953
Date: 8/1/2000
Property Owner:
Property Address: 3415 KENDALL ST
Contractor License No.: 19814
Company: Westside Heating and Air Conditioning Inc
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Phone: 238-2849
Phone: 469-4507
I hereby certify that the setback distances proposed by this permit application are accurate,
snd do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and 8!;1ree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U,B,C,) and all other applicable Wheat Flidge ordinances, for work under this permit
(OWNER)(CONTRACTOR) SIGNED
DATE
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
Total:
$2,000,00
$69.25
$0.00
$30.00
$99.25
Description:
INSTALL NEW 2 TON AlC UNIT
BUILDING DEPARTMENT USE ONLY
Approval :
Zoning:
Approval:
Occupancy:
Roof:
Stories:
Walls:
Electrical License No :
Company:
Plumbing License No :
Company:
Expiration Date:
Approval:
Expiration Date :
Approval :
Use:
SIC:
Sq. Ft:
Residential Units:
Mechanical License No :
Company:
Expiration Date:
Approval:
This permit was iS$uecI in accordance with the provisions set forth In yopur application and Is sub.led to the laws of the State of Colorado and to the Zoning
Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City.
This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a period of 120 day's.
If this permit expires, a new permt may be acquired for a fee of one.half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or If suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceediing uccessive hases of the job.
The i of pe it or approval of drawings and specifications shall not be construed to be a permit for, nor an approval of. any violation of the provisions
of the bUl 9 r ordinance, law, rule or regulation.
,~
Chief Building Insp"6ctor
(1)
(2)
(3)
!~l
(6)
:'\
w?-
DEPARTMENT OF PLANNIN,G AND DEVELOPMENT Building Permit Number:
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date: '7- d-.5 -() 0
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner:
Property Address:
Contractor License No, :
Company:
?',c.r.... S'Te.G'feL _
3'-1/5 Ke,.;dQLL 81
I q \l' Ilf
We.sTS'I~e N ec.T,'iU1 <tAlC. j:,.;c
Phone: 301 -;;p ~-d? 't 'i
Phone: 303- 41a9- <{56]
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
J., 0." .0 ",
lOq JS
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate
and do not violate applicable o~di.nances, rules or regulations of the City of Wheat Ridge or'
covenants, easements or restnctlons of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibHity for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit.
(QWNER)(CONTRACTOR) SIGNED &A~ flrl ~ ' DATE '7.,;J,s-()Q
o
Description: ItJSTAL1... New d- Tc),0 Ale UNIT
:')0> 00
qq d.:J,
Total:
BUILDING DEPARTMENT USE ONLY
ZOh:!)!gtC"Olll'i'if~
Approval:
Zoning:
Bm{CIrnm.uolJ1men~
Approval:
P.tmTrel~~
Approval:
Occupancy: Walls:
SIC:
Sq, Ft:
Roof:
Stories:
Residential Units:
Electrical License No :
Company: wes Te 0 ELrc TL, c
S3QJ..
Expiration Date: () ';)./ d-~l ~oo I
Approval:
III
Plumbing License No :
Company:
Mechanical License No: I 9 ~ I '-I
Company: uJE'S' T S /q <0 f.I T<:f'l- Ale..
.~. :l~.lillG#,: ,:
Expiration Date:
Approval:
.
Expiration Date: ,3-:1" 01- 0 '"
Approval:
,- il;i..... ':', .
.
.10 t:.lIb ;'QUlJj" >. "
(4)
(5)
(6)
This permit was issued in accordance with the provisions set torth in yopur application and Is subject to the ta'^" of the Slate at Colorado and to the Zoning
Regulations and Building Code ot lJIIheat Ridge, COlorado or any other applicable ordinances of the City.
thiS permit shall expire If (A) the work authonzed is not commenced within SiKty (60) days from Issue date or (B) the building authorized Is suspended or
abandoned lor a period ot 120 days.
II this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made In the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. tf changes are made or it suspension or abandonlTM!lnt
exceeds one (1) year, full fees shall be paid for a new permit.
No work 01 any manner shall be done that Will change the nalural flow or water causing a drainage problem.
Contractor shall notify the Building Inspector twenty.four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceedhng WIth successive phases ot the/"Ob. " '
The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit tor, nor an approval of, any violation of the proviSions
of the building codes or any other ordinance, law, rule or regulation.
(1)
(2)
(3)
Chief Building Inspector For Mayor
THIS PERMIT V AltO ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MA VOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
DEPARTMENT OF PLANNING AND DEVEl10PMENT Building Permit Number:
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date: I - 7- Oc:.
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner:
Property Address:
Contractor License No. :
Company:
S T leA /,,:/EC/7
3 '11 5' /c::!~;:Jd~?
ICjfiJ 1-
~* 1/7&-
s...r-
Phone: ;L:5 ~ - 2 2r ~
-'
Phone: '13 /- f'~ /..J
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat "age din s, for work under this permIt.
Use Tax:
)'vc<
).'3
tP
rc-
.,>
7;:>
Construction Value:
Permit Fee:
..-
(OWNER)(CONTRACTOR) SIGNED
TE /. J-<:-
Total: 3 a. .2---
Description:
!2-1z- J t # c--C W /H7 /L /r~
BUILDING DEPARTMENT USE ONLY
Approval:
Zoning:
Approval:
~...
Approval:
Occupancy:
Walls:
Roof:
Stories:
Residential Units:
Electrical License No :
Company:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval:
II _5RlJODli'M'I~
Expiration Date:
Approval:
. IfJlll(MlBh'''..\lri1l1
Expiration Date:
Approval:
.
(1)
(2)
(3)
This permit was issued in accordance with the provisions set forth in yopur application and is subject 10 the laws of the State of Colorado and to the Zoning
Regulations and Building Code of VVheat Ridge, Colorado or any other applicable ordinances of. the City.
This perm.t shall expire jf (A) the work authonzed is not commenced within sixty (60) days from Issue dale or (B) the buJlding authorized is suspended or
abandoned for a period of 120 days.
If this permit expires. a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paId for a new pennit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceedllng WIth successive phases of the lob,
The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for. nor an approval of, any violation ot the provisions
ot the building codes or any other ordinance, law, rule or regulation.
(4)
- (5)
(6)
Chief Building Inspector
For Mayor
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
:;f~;--tt,!~Jf;~~~~",~~~;,;;,,,;W' .,' ," ~;m ~~~:~"",~rf",,1\~ "",~~?,;;UK\'i\,~,\",;/~@,,+~~J.6L~"!'''';~~''fJf.,~,,1~~,NJ~l("",,,",~,,:>:~,,,1t",0',v;;~,,~,;~~W'W.,IJ,,,,,,,,,,,,.'!:'~,,<r'.7:":~~""f$t:ll~Ul!D~,t;t,~~,,;~,~;
.J)EPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 6770
. BUILDING INSPECTION DIVISION. 235.2855
CITY OF WHEAT RIDGE Date: 3/24/98
7600 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Properly Owner:
Properly Address: 3415 Kendall Street
Contractor License No.: 19814
Company: Westside Heating and Air Conditioning Inc
. WNERlCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Phone: 233-4151
Phone: 469-4507
Construction Value :
Permit Fee :
Plan Review Fee:
Use Tax:
$1,650.00
$55.00
$0,00
$24.75
$79.75
hereby certify that the setback distances proposed by this pennft application are accurate,
,nd do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
venants. easements or restrictions of reCOrd; that all meesurements shown. and allegations
, ade are accurate; that I have read and agree to abide by all conditions printed on this
. ppllcatlon. and that I a..ume full~sibility for compliance with the Wheat RIdge Building
, ode (U,B,C,) and all other applicable Wheat Ridge ordinances, for work under this pennft.
Total:
DATE
Use:
Description:
Replace old furnace with new GFA, 100,000 BTU's
BUILDING DEPARTMENT USE ONLY
SIC: Sq. Ft. :
Approval:
Occupancy :
Walls:
Roof:
Stories:
Residential Units :
Electrical License No :
Company:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval:
Expiration Date:
Approval:
Expiration Date :
Approval:
(1) ThIs pennIl was _In accordance with the provtolons 181 forth In yopur application and Ilsublecl to tholawll of tho state of Colorado and to the ZOnIng
Regulations and Bulkflng COde of Wheet Rldoo. Colorado or ony other oDOllcablo onllnances 01 tho CIty,
(2) This pormil_ axplre K (A) the wor1< authorIZed II not commancad wlth1n IIxty (60) dayl from Issue da1a or (B) the building aulholiZad Is suspended or
abandoned ror a petIod 0I1211 dsy'l.
(3) K this pormil expires, anaw.penn~ may be acquIrad for alas of one-haW the amount nonnally requlled. _ no changes have boon or wi" be made In the
original plans and ~.nd any suspension or abandonment has not oxcaeded OIlS (1) year, If changes IlIe mOde or W IUSpansIon or abandonment
exceadl OIlS (1) year, IulIIaao shall be paid for a new_
(4.l No work of any manner shen be done that will change ttte'natural ftow of water causing a drainage problem.
( CQntractor shall notify the BuIldIng Ins_lwenty-rour (24) hours In advance for aIIlnspacllons and shall raceIve written approval on InspecIIon card -
OIOC8*dilng with _ ""- 01 the Job.
(6) 'rhe Issuence oIa pormil or tho approval of dJawings and speclllcello< ," shall not be conllruad to be a pormil for, nor an approval of. any violation 01 tha pmvIsIons
cwollha building codes or any other onllnance, law, rUle or regulation,
. _ fI !' ( .% I A :t-- , (121
Chief Building Inspector ' r
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
~;v
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number:
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date:
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner: k Ie rI ~772fif::J6-7e/
Property Address: !!JlJ I ~ /< eN z;q-t-e- 6r
Contractor License No: '* 1'7~I'-I liP)'.;? /":2llgN;
Company: WE:67S IDr:;: /-k:J-tTIN G .fA Ie
Phone: ;{38 -)j/~ /
Phone:~-~C;-Vj7
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
/&50.00
:Y500
cY<{,75
J hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rutes or regulations 01 the City of Wheat Ridge or
covenants. easements or restrictions of record; that all measurements shOwn, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full respons:ib(lity for compliance with the Wheat Ridge Building
Code (U.8.C.) and all other ap~I:,,~J'at Ridge or~ina~?S, for work U~der this permit.
(OWNER)(CONTRACTOR) Sl~ --4'1.1 /YdV1 /&MubATE .:5;4'1/16'
Description :t:epZHCG cia:> ;:;U2t<J4CG Willi ,!Jt;;:)()/ aF14,
BUILDING DEPARTMENT USE ONLY
Total:
ItJtJ,tM{) 17/U 'S
~!ilhlllClSl1'Ol\.lltl::l
Approval:
Zoning:
BUlJClllilftGommel!tij~
Approval:
SIC:
Sq. Ft.:
. .. .'li:J~.;.; ',":!!liJJiiIJi\D:
Approval:
Occupancy:
Walls:
Roof:
Stories:
Residential Units:
Electrical License No :
Company:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval:
Expiration Date:
Approval :
Expiration Date:
Approval:
.
,. Die; ,;!:.\; ('1 U,:
.
I" Jtl;..l; '"l'.Jk;~
.
1- UrL: :;_~lUl~~'
(1)
(2)
(31
This permit was issued in accordance with the provisions set forth in yopur application and Is sub;ect to the laws of the State of Colorado and to the Zoning
RegUlations and BUIlding Code of Wheat Ridge, Colorado or any other, applicable ordinances of the City.
ThIs permit shall expue if {A} the work authOflZed tS not commenced with'" sixty {601 days from issue dale or (Bl the building authorized is suspended or
abandoned. fOr a pe/'iO(l Or 120 days.
If this permit expires, a new per""t may be acquired for a fee of ooe-half the amount normally required, provided no el\anges have been or will be made in the
original plans and specifications and any suspension Of abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
el(ceeds one (1) year, full fees snail be paid for a new permit.
No work of any manner snail be done that will c:hange tne natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty.four (24) hours in adVance for all inspections and shall receive wntten approllal on inspection card bf!fore
proceediing Wltn successIve phases ot the job.
'rhe issuance of a permit or the approllsl of drawings and specifications Shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of Ihe building oodt!s 01 any other ordinance, law, rule or regUlation.
l41
5)
(6)
Chief Building Inspector For Mayor
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234.5933 24 HOURS PRIOR TO INSPECTION