HomeMy WebLinkAbout3010 Jay Street' City of Wbeat Ridge
Residential Roofing PERMIT - 201704975
PERMIT NO: 201704975 ISSUED: 07/27/2017
JOB ADDRESS: 3010 Jay ST EXPIRES: 07/27/2018
JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration Storm asphalt
shingles with ROOF DECKING - 30 sq.
*** CONTACTS ***
OWNER (719)322-4132 MAZZETTA MARCY L
SUB (720)323-3673 Matthew Savarie 1.70224 Ceramic Mosaic LLC
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,128.11
FEES
Total Valuation 0.00
Use Tax 380.69
Permit Fee 346.95
** TOTAL ** 727.64
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
INSPECTION RECORD
INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection
INSPECTION REQUEST LINE: (303) 234-5933
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Oc, aL arcc , rype
V 11
Inspections will not be performed unless this card is posted on the project site.
**Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date Inspector
Initials
Comments
Pier
Concrete Encased Ground (CEG)
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
Foundation / P.E. Letter
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground/Slab Inspections Date
Inspector Comments
Initials
Electrical
Comments
Sewer Service
Plumbing
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections
Rough Inspections
Wall Sheathing (�
Date Inspector Comments
Ini i
Mid -Roof
Comments
Lath /Wall Tie
Rough Electric'
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
Rough Plumbing/Gas Line
Rough Mechanical
Floodplain Inspection (if applicable)
Rough Framing
Rough Grading
Insulation
Final Electrical
Drywall Screw / Nail
Final Inspections
Date
Inspector
Initials
Comments
Landscaping & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW & Drainage / Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
Final Plumbing
Final Mechanical
Roof
4K 117
Final Window/Doors
Final Building
NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
*For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office - (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: L
Job Address:. /0 T19 -S
Permit Number: ?_'40 / i 0
L 7,
F' No one available for inspection: Time AM/PM
Re -Inspection required: , Yes,) No
When corrections have been made, call for re -inspection at 303-234-593
Date: Inspector: h."
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
_1�9�Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: t � U r
Job Address: �Ul U
Permit Number: '1
❑ No one available for inspection: Time V--, ' T;r'`AM/PM
Re -Inspection required: Yes L o
When corrections have been made, call for re -inspection at 303-234-5933
Date: Inspector:
DO NOT REMOVE THIS NOTICE
J City of Wheat Ridge
i Residential Roofing PERMIT - 201704975
PERMIT NO: 201704975 ISSUED: 07/27/2017
JOB ADDRESS: 3010 Jay ST EXPIRES: 07/27/2018
JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration Storm asphalt
shingles with ROOF DECKING - 30 sq.
*** CONTACTS ***
OWNER (719)322-4132 MAZZETTA MARCY L
SUB (720)323-3673 Matthew Savarie 170224 Ceramic Mosaic LLC
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 181128.11
FEES -
Total Valuation 0.00
Use Tax 380.69
Permit Fee 346.95
** TOTAL ** 727.64
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
City of Wheat Ridge
Residential Roofing PERMIT - 201704975
PERMIT NO: 201704975 ISSUED: 07/27/2017
JOB ADDRESS: 3010 Jay ST EXPIRES: 07/27/2018
JOB DESCRIPTION: Residential Re -roof to install Owens Corning Duration Storm asphalt
shingles with ROOF DECKING - 30 sq.
I, by in signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the roperty and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�ppermit. I further attesfthat I am legally authorized to include all entities named within this document as parties to the work to be
performe and that all w k to a performed is disclosed in this document and/or i I
s' accompanying approved plans and specifications.
/3017
Signature of OWNE or CONTRACTOR (Circle one) Date
I. This permit was issued based on the information provided in the permit application and accompanying Flans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The i or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
appli b de or any ordce or regulation of this jurisdiction. Approval of work is subject to field inspection.
'gnature of Chief Building Official Date
VESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dan Schultz
From: no-reply@ci.wheatridge.co.us
Sent: Wednesday, July 19, 2017 8:50 AM
To: CommDev Permits
Subject: Online Form Submittal: Residential Roofing Permit Application
Categories: Danny
Residential Roofing Permit Application
P7�
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes /
residential roof? N
/ 6
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number
Property Owner Email
Address
3010 Jayr j
J
Marcy L Mazzetta
719-322-4132
Field not completed.
t7c3lL7,6z�—
Do you have a signed Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
Contractor's License
Number (for the City of
Wheat Ridge)
Contractor Phone
Number
Ceramic Mosaic Ilc ; `.-
107224
720-323-3673
Contractor Email Address ceramicmosaicllc@gmail.com
Retype Contractor Email ceramicmosaicllc@gmail.com
Address
DESCRIPTION OF WORK
Are you re -decking the Yes
roof?
Description of Roofing
Material
Select Type of Material:
If "Other" is selected
above, describe here:
How many squares of the
material selected above?
Does any portion of the
property include a flat
roof?
If yes, how many squares
on the flat roof?
'1
Owens corning Duration Storm
Asphalt
Field not completed.
30
No d
Field not completed
TOTAL SQUARES of all 30 "
roofing material for this
project
Provide additional detail House 5/12 pitch
here on the description of
2
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract 18128.11
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Matt Savarie
Email not displaying correctly? View it in your browser.
p_..3.....a, r
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION N TICE
Inspection Type: �-
Job Address: �a10 1l 57�
Permit Number: 00/72�
♦ i CITY OF WHEAT RIDGE
f 3) Building Inspection Division
(303) 234 -5933 Inspection line
235 -2855 Office • (303) 235 -2857 Fax
INSPECTION NOTICE F- }
Inspection Type:
Job Address: 22111 `7ss 2f _< i7 - -
Permit Number: A L!/}
❑ No one available for inspection:, AM /PM
Re- Inspection required: Yes /No
* When corrections have been mad ( e jfo� - inspection at 303 - 234 -5933
Date: Inspector: #
~oF "Heq?q City of Wheat Ridge Building Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 " Fax: 303-235-2857
c ° Inspection Line: 303-234-5933
OLORAO.
.
Building Permit Application
Date:
Plan ~y
Permit f I,
PropertyAcldiess+ 3z)lo ~c~US{Y2e
Property Owner (please print): haxY k Mazel a Phone:`-`Iq -3;G--`J13D)
Mailing Address: (if different than property address)
Address:
City, State, Zip:
Contracto : 4+rdf,(( ~ nvimnvvla I,~~(r Fi i f LLC
Contractor License OYW 6 Phone:
Si%b~ Contractors
Electrical City License 00006~7, Plumbing City License Mechanical City License
Company/fs{yAw~~y1 fOatW~s~ Company Company:
.Srlc~tial.SjLLG
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: App
Use of space (description): I Construction Value' $
(as ca/cu/atetl per the 8 3
"dmg Valuation t sheet)
bescn/pttonLOfwork/ z.` i,)~~
N.5 rp,!(G~"IlOl~i of a ~a 'V~hw 5d~Q 0-~~ Plan Review(due attimeofsuhmittal):$
1 s FI1
Sq. Ft./L.Ft added: Squares BTU's Gallons Amps
OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to field ins ection.
OIRLCE ONE:: (OWNER) CONTRACTOR) . or PERSONAL REPR TATI Rt"COw ER) (CONTRATOR)
PRINT NAME: ~l{G VAP 1 e P_.LA. SIGNATURE: Date:
kESTRUCTION
PPORT
RVICES
July 22, 2009
Mr. Aaron Hesterman
Astralux Power Systems
2500 Central. Ave
Boulder, CO 80301
RE: Suitability for installation of a Solar Array on: 3010 Jay Street Wheat Ridge CO 80214
Dear Aaron:
Thank you for the opportunity to examine the roof framing system at the above address to
determine the acceptability for the installation of a new Photovoltaic Electrical system. We
examined the attic to see the roof supports, the house for existing cracks from other
movements and the exterior. There are always areas that are not observable and we attempted
to determine the framing method in those locations.
Criteria: Distributed Dead Loads:
APPROVED
to Field tnspections
Building Dept.
Roof type: Asphalt Shingles
Misc. ( Sheathing, insulation, etc.)
Total Distributed Load (psf)
Design Criteria: Wind Loads: (Using ASCE7-02)
5
5 I Sicnedi` Plan checker
10 TT-W
Z to 4 A l1 M\ t#'~f$ a
id (h
PA .t J~ .t
b
al
! A A y L` } I <,1 M r 3
S
W
if'p ~r
d 4 Y i
4 T -
\x tw
,
n.pp
qq
RN~
k
R
i
e.
R
547
A
++~k
y
`1
YSS G[..'A✓"Y~LQJ
~
B5y~
k
n.~u'P..rcYdus 3+6'x. a1n.A dn':? .(T~'4, 3JYi'2.ra ab .t .wa.4%
Wind Velocity
120
Local Building Code
Exposure
C
Assumed
Importance Factor
1.0
Assumed
Height to top of array
30 feet max.
Based on house
Area of array
14.2
Based on panel dimensions
(square feet)
(32"x64")
Wind loading
36.1
Assumes: Directionality=l, Kx=.98,
(Psf)
Kxt=1
7901 S. Adams Way Centennial, CO 80122-3601
303-221-1559 phone consupser@mae.com
Wire Gauze Calculations
Mazzetta Residence
3010 Jay St..
Wheat Ridge, CO, 80214
System description: 12 Sharp ND-N2ECU 142 W stc solar modules, Fronius IG 2000 (240V) inverter
One string of 12 panels on inverter
DC ParametersM
1. From array to EMT conduit junction (cables in free air)
Ise x t x t = Short Circuit Current
7.92Ax 1.25 =12.4A
10 AWG Cu USE-2 good for 22.6 Al§ rtl {55A x 0.41 temperature correction factor = 22.6 A}
2. Cables in EMT conduit to unfused DC disconnect (partially on roof, partially on exterior wall)
Operating current = Ise x 1.25 x 1.25 x # of combined strings in parallel:
Ise x t x $ x Np = Ioc
7.92A x1.25 x1.25x 1 =12.4A
Date: 7/1/09
v.P3
10 AWG Cu USE-2 good for 16.4 Alt:,§§1 {40 A x.41 temperature correction factor x 1.0 correction factor for two
conductors in conduit: one pos & one neg}
3. Cables in EMT conduit from DC disconnect to inverter (on exterior wall)
Ise x f x $ x Np =1oc
7.92A x1.25 x1.25x 1 =12.4A
10 AWG Cu USE-2 good for 36.4 Act:.§§1 {40 A x .91 temperature correction factor x 1.0 correction factor for two
conductors in conduit: one pos & one neg}
4. Operating Voltage = Maximum Power Voltage x 1.25c*..1 x # of panels in series
Vpm x x Ns = Vo
20.0 V x 1.25 x 12 = 300 V
5. Maximum System Voltage = Open Circuit Voltage x 1.25(***) x # of panels in series
Voc x x Ns = Vm
24.9 V x 1.25 x 12 = 374 V
AC Parametersttt
1. Max AC Output Operating Current = Inverter nameplate of Max Continuous Output Current (continuous duty) = 8.35 A
10 AWG Cu THHN good for 36.4 Actt•§§1 {40 A x 0.91 correction factor} from inverter to unfused AC disconnect (in EMT
conduit), and from disconnect to 20 A 2-pole breaker in house main AC panel
2. Max AC Operating Voltage - Inverter Nameplate ( i.e. 120, 208, 240, 277)
Nameplate is 240 VAC
Photovoltaic Installation Electrical Diagram
Rated 1704 watts under standard test conditions
Solar Panel Array 1
(12) Sharp ND-N2ECU Solar PV Modules
Wired as a single cedes string.
USE-2 in two air AC disconnect Is accessible. 8888
IQAWG Gu Wlre visible d Imitable, and is
labeled with placard: Utility motor
`tGTp~oY,7,YG pee
D~
Silicone-filled VE
seal-tight Eiii Junction The distance between disconnect
Smlllty meter is-3'
USE-2;n 112" EMT Conduit
10 AWG Cuwlre
ZO A R-pole `
20A2 r
to
AC main panel
DC disconnect
lunfueed) THNN In 117' EMT Conduit
10AWG CPPfiro (stranded)
USE-2 m 112" EMT Conduk AC Disconnect
10 AWG Cu Wire Untused 20A
6Q -
Fronlus lG 2000 inverter PerNEC890ATD-
Max output-8.30 A @ 240 V AC \
&AWG DC System Grounding Conducts. with crimped connections run M AC System Grounding ElacaWe or crimped to AC System Gm achni Conductor 0net accmalde.
.\MIn S' apart/
~
Ertl`
n.. Mauetta Residence
PAOwN 'Iiree•une EIedrlwl8dlanmk
J FM~~A
~rm'wtaawm
~•p vui~am
ooeYmHXgr, edranet+le
AahYinrEmironmeriW
Solutions
srlaxmaus:
3010 J
St
me Orld-Tied Solar Bacilli; Symom
ituoiscoateal
ay
.
W
fteatridge, CO. 80214
Steve Whipple
P3
NTS 711109
m rw
a
im.
LN
Z
Q
2
y
O
~
+
C
p ~
15m
3. o a z arcs
o m G o dam
m %O W a J
0 N Ny Y ~N
/
O
UYI F6W
W Y
as c p
Q
4
0.5
~ E:
u N
O, t O m P Z:
a ~E N tZ4
U
U
r-I
ri
J
u
v v a E 'fisz
'IE
-
LL
U
t
(n i ~
tt
E
:11
cc WE t v v •y V30
i
,
wy £&z
E=
F
f]
u
a NN C >SOw
U U p
~
LL
LL
N
E
0
~
OF~
a
N
N
N
O
i
V
I a
i
% w Y/I O. I`N~
10 `5 zu :9 ooG=
_
rny. z p~
c
_
03
(a
f6
a 9az
° 3v x
E E'k c c coop
M M, E- 18
E E- m az
O
.
O ~m mo my z%oi
i
aw
U
5
LL
.~~.p//
~
J N r- ~
a
'
QS
`
LL
U .a N M d
m
Z
zQ
O
~
~
m
0
0
0
0
0
O£FU
z
0
0
0
a
LL
LL
LL
3
w
5
~
~
t
°
. zz>~
N
N
N
N
`od
l
8
I
S
a
a%w))
(a.
3
U
$
g
N
N
w
-
o
£ r n p
Q
g
a
q
good
T~
T~
b
N
LL
N
~
Z6
U
-
J
LL
o~=
E=
=1
~
QOaQ
a~
~
~
U
~
~
n
Q
Q
°
~
6~Or
m
wo
~
o
LL
Q
u2C%
y
I
J
LL
u
62
4-J
/ T7
LL~Lc 6
Yo
o
~
~
~
Q
O
O
O
O ~i~°
a
a
a
a
a
~
Wr
o~oz
p
V /
W
92H
b
@
¢
~
0
Q
-
./mil
a
L 41
C
C
N
N%
N
g
¢
m
~
2
LL Q
2
dg
N
¢
b
¢p
' rp
C
LL
b
¢
X V• N G Z
bZ
QO
a
~^cc
rcz=
Z
~
Ij' V
SHARP
solar electricity
142 WATT
OnEneil
SYSTEM MODULE
RESIDENTIAL 142 WATT
MODULE FROM THE WORLD'S
TRUSTED SOURCE FOR SOLAR.
This -Iigh-quality residential soiar module
is oesigned anh englneereo for .use with
vise Sharp OnEnergy soiar systern. Sharp's
7nEnergy system replaces the bulky look
of tracltional solar roof mounts with a clean,
c-legant appearance that blencs .;eautifully
wits, roofnes. lisin_g breaktI,rough technology.
mace possible by nearly 50 years of proprietary
--research anc oeveloorrie'lt thIs..rnocule
incorporates an acivancec surface texiunng
process to increase light absorption ano
impicve efficiency loeal for virtually all sizes
of I:esidential solar systems, this rrl ,dule offers
irrlproveo aesthetics and Uurabiiity under the
most rigorous operat rg concitions.
ENGINEERING EXCELLENCE
Designed and engineered for use with sharp's
OnEnergy solar racking system, this module is the
perfect combination of technology and design.
ADVANCED AESTHETICS
Blac frame module, and associated racking witn
hidden hardware and tapered covers. delivers a
clean, elegant appearance that blends beautifully
with your home's roothne.
DURABLE
Tempered glass. EVA lamination and
weatherproof backskin provide long-life and
enhanced cell performance.
"RELIABLE
25-year limited warranty. on power output.
HIGH PERFORMANCE
This module uses an advanced surface
texturing process. to increase light absorption
and improve efficiency. -
ND-N2ECUF
(y o
u
1^ n
142 WATT
ND-N2ECUF
ELECTRLCALtHARACTERdSTIdS
Maximum Power.(Pmax)'
142 W
Tolerance
+10%/-S%
Type of Cell
Polycrystalline silicon
Cell Configuration `
42 in series
:Open Circuit Voltage (Voc)
25.24 V
Maximum Power Voltage (Vpm):
19.92 V
Short Circuit Current Osc)
T84 A
Maximum Power Current (Ipm).
7.13A
Module Efficiency
12.31%
Maximum System (DC) Voltage.
600 V
Series Fuse Rating
15. A
NOCT
475°C
Temperature Coefficient (Pmax)
-0.485%/".C
Temperature Coefficient (Voc)
-0..3651/°C
Temperature Coefficient(Isc)
0.0539,;/`C
'weasu I.a at ISTC SardA.d T9 5t C..IIJ as 25"C
, 1 kw/-t'. All r
MECHAMiCAL CHARACTERISTICS
Dimensions (A. 6z C below) 45.87'y 38
.98" x1.81't1165x 990 s 46 min
<Cable. Length (H) Si:211300
mm
Type of Output Terminal Lead Wire with MC Connector
Weight: 31.96 Ibs
/ 14.5 kg
Max Load 50 psf (2400 Pascals)
LiUALIFICATIONS
UL Listed UL 1703
. c, ~L. us
Fire Rating -Class C
WARRANTY
25-year limited warranty
Contact Sharp for complete warranty information
u•c '4 t'.. [1
5 y n h n[ 111 kv ew p10(.Sr1y of
nGr-Sorizv_ V OnEre_9. O All icla[Rn otlPn b,,,S •I C9 .~.i
" .rh IIII It ,M1a G, n_reLA,'4.WC .ar:An,aw ""."es:._-.a.,r;
-p h."tyI v :ema- . Al w~ct,' ' =qupmenn uen5 ery .n
' c"r.17 S n ar: 13 --.a r.ne Idle. ,Iar✓J_I rEU .111.1111,
SHARP
IV CURV'ES'-""
7
eoolw m9 1m
5
jW
w x
4
co
3
N
r
0 0
o s to Is za u sa
lbnMeM ~GVrcNrcW~pe.
ewrenevwmws.wuaye enaamm~il: - w,e.a:wov.
SID]
A a C;.. D.. E
45.67"/1165mm $5.95';r990 mm 1.bt"J46rAArI 72 "/i^o2.5 mm 15175"1400 ni
F G. : H
7.67-/200 mm 36:55-/936 mm. 512 11 00 mm
\..Gr~td<i. SY r(I tpI 50CIdnC?St2CIhICa[ian5
SHARP ELECTRONICS CORPORATION
5901 Bolsa Avenue, Huntington Beach, CA 92647
1-800-SOLAR-06 • Email: sharpsolar@sharpusa.com
www.shafptisa.com/solaf
5002 Sbarp Electronics Corporation. All lights reservec. 0151`-010 •V?-06-08
BACK VIEW
FRONIUS IG
GRID-TIED INVERTERS FOR PHOTOVOLTAIC SYSTEMS
Light Weight
At 26 Ibs, the FRONIUS IG inverters are the lightest grid-connected
inverters making them easy and cost effective to install.
Flexible
The wide voltage range of 150-500 V allows you to use different types
of modules and system configuration possibilities.
Lower Cost
Integrated UL approved DC & AC disconnects which reduce installation
time and complexity - often eliminating the need for additional disconnects.
LCD Display
User-friendly and comes standard with every FRONIUS IG; tracks
more than 20 critical system performance parameters.
Plug-and-Play
Expansion slots in the inverter allow you to easily upgrade the inverter
with data communication options.
Reliable
Fronius has been in business for over 60 years and has more than
200,000 FRONIUS IG inverters installed worldwide.
Warranty
10 year Premium Warranty.
POWERING YOUR FUTURE
k
ommended PV power
"'.(:{1}(
1500 - 2500 Wp
-~i~MA~l.1AT~rNr.,'S14)YF!_k._. `N~
2500 - 3300 W
Dil
a.1^
1800 - 3000 Wp
x. DC input voltage
L
500 V
500 V
500 V
eratin DC voltage range
150 - 450 V
150 - 450 V
150 - 450 V
x. usable DC input current
AW;
" tp" Daft . : . . .
Maximum output power ®40' C
13.6 A
: , l{fS IG 800C; : „
2000 W
18A
" , 30p0
2700 W
16.9 A
"F(#fNIUB
2350 W
Nominal AC output voltage
240 V
208 V
Utility AC voltage range
212 - 264 V (240 V +10%_/ -12%)
-
183 - 227 V
Maximum AC current
8.35 A
1725 A
11.25 A
Maximum utility back feed current
0.0 A
0.0 A
0.0 A
Operating frequency ran a
59.3 - 60.5 Hz (60 Hz nom)
Total Harmonic Distortion THD
<5%
Power Factor (cos phi)
Max. efficiency
1
" ~FRONIWS-A
95.2% 95.2% 94.4%
Consumption in stand-by
< 0.15 W (night)
Consumption durioperation
_
7 W _
Enclosure
NEMA 3R
Size (I x w x h)
18.5 x 16.5 x 8.8 inches (470 x 418 x 223 mm)
Weight
26 lbs. (11.8 kg)
Ambient temperature range
-5 to 122'F (-20 to +50 °C
Cooling
controlled forced ventilaton
Integrated AC and DC disconnects
Ground fault protection
standard UL approved DC & AC disconnects
~ G. w,b' $'C`Si` w nt,k~' z4 2s,, fi S)
Internal GFDI, in accordance with UL 1741
DC reverse Polarity protection
Internal diode
Islanding protection
-
Internal, in accordance with UL 1741, IEEE 1547
-
Over tent rature
Output power derating
Su a rotection
Safe
Internal DC & AC rotection, Tested to 6 kV
UL 1741
EMI
FCC Part 15; Class A & B
Anti-Islanding protection
UL 1741, IEEE 1547
Ground fault detector and interrupter
Maximum AC over current protection
Complism with NEC Art. 690 r uirements, UL 1741
Two-Pole, 15 / 20 A circuit breaker
AC wire sizing
Use maximum AWG 6 194'F (90 nC) copper wire
DC wire sizing
Use maximum AWG 8 194-F (90 °C) copper wire
AC disconnect
16A
DC disconnect
25 A
Warranaa~__
10 year Premium Warranty is Standard
ralux Solar Electronic USA LLC
Solar Division
10421 Citation Drive
Power Systems
A DlWalon of Afl/aln• EnHronmonlal Solullons
Suite 1100 Brighton, Mi 48116
Phone: 810-220-4414
Fax: 810-220-4424
E-Mail: pv-us@fronius.com
www.fronius-usa.com
GREG RILEY PROFESSIONAL ENGINEER
STRUCTURAL ENGINEERING CONSULTANTS , INC.
27200 TOURNEY ROAD SUITE 390 VALENCIA CA 91355
TELE: 661.287.5800 FAX: 661.287.5855
m
E • M A I L:info@structuralconsulting.co
W W W.STRUCTURALCONSULTING.COM
June 5, 2007
Sharp Electronics Corporation
Solar Energy Solutions Group
5901 Bolsa Avenue
Huntington Beach, CA 92647
Attention: Mr. Arthur Rudin
Director of Engineering
Re: Static Load Test
SRS Residential Rooftop Photovoltaic Module Mounting Structure
Asphalt Shingle Attachment
Dear Mr. Rudin
This letter shall serve as documentation of our various observations of the above
mentioned tests performed at the Sharp Electronics Corporation facility in Huntington
Beach, California in the spring of 2007.
Product Description
The SRS mounting structure is designed to be used on residential roof tops. The structure
is attached to the roof top and the photovoltaic modules are then attached to the structure..
The version tested is designed to be used with various types of roofing materials. These
include Spanish concrete tile, flat concrete tile, clay concrete tile, and asphalt shingles.
The attached drawings from the installation manual illustrate the installation process.
The SRS mounting structure is constricted from roll-formed and pressed sheet metal
parts and stainless steel fasteners. The sheet metal parts are galvanized with a Super
Dyma® coating, similar to Galvalume, containing Zinc, Aluminum and Magnesium for
corrosion protection.
Purpose:
The purpose of the Static Load testis to observe that the mounting structure can
withstand a static load of at least 50 PSF (pounds per square foot) in both the
"downward" and "upward" directions as shown in the attached test diagrams. The
"downward direction is used to indicate snow loads and impinging wind loads in a
direction normal to the front surface of the solar module. The "upward" direction is used
1
to indicate uplift caused by high wind speeds when airflow under the module produces
pressures up to 50 PSF.
Materials:
A test structure consisting of 4x8 and 2x8 timbers as shown in the diagram was
constructed to support the SRS mounting structure. The timbers were arranged for 48
inch on center spacing so that four ND 187U1 modules arranged in two rows and two
columns could be mounted in a portrait fashion. 12 inch x 16 inch rectangles of 15/32
oriented strand board (OSB) were placed on the structural members to simulate the wood
deck of a standard residential roof top. The SRS mounting structure was then installed as
shown in the attached installation manual. Six wood screws were used to attach the
aluminum plate. The 3.15" wood screws were used to attach the plate to the structural
member while the 1.4" wood screws were used to secure the plate to the wood deck.
Once the aluminum plate was attached, the tile standoff and slider were place 4 inches to
the right of the centerline of the structural member using the 5.3" stainless steel screws.
The rest of the SRS components and modules were then installed in accordance with the
installation manual. The talon clips module mountings were placed 8 inches from the
comer of each module.
Procedure:
50 pound bags of construction sand were individually weighed to the nearest 1/10 pound
and marked. A dial indicator with 2 inch range was placed on a block of wood under the
test structure to measure the total deflection during the loading stage. The test structure
was supported by cinder blocks as shown in the diagram. With the test array in the
normal direction (modules facing the sky) sand bags were individually placed on top of
the modules while the weight of each bag was recorded. The sand bags were evenly
distributed so that the array was uniformly loaded to the best of our abilities. Once the
total load was equivalent to 50 PSF no more sand bags were added and the structure was
allowed to sit undisturbed for 30 minutes. During this time the deflection was recorded
on the dial gage approximately every 2 minutes. After 30 minutes, the array was
unloaded and flipped 180 degrees so that the front surface of the modules was facing the
ground. The test was then repeated in the same fashion placing sandbags on both the
modules and the SRS rails.
Pull Out Testing
Pull out testing of individual mounting components was performed on the main
attachment methods for the Sharp SRS system. The tile attachment and flashed
attachments were tested to obtain pullout values for each. The pullout force was applied
and measured. Failure was indicated when the peak load was observed.
March 12, 2007- Preliminary testing was performed. Initialrig used a bolt through the
mount for pull up.
Flashed Attachment #i- Attachment of flashed slider into a Douglas fir rafter through
15/32" OSB. Peak load occurred at 17541bf. However first peak was observed at
-1450pf. Deformation of the slider occurred due to point load from the pullout harness.
Screws were not pulling from the rafter at that time.
Tile Attachment #1- Attachment of tile attachment into aluminum plate and 15132"
OSB. First peak at -6801bf was observed. This related to some deformation of the
aluminum. Additional Peak at 7641bf was seen. Then complete failure when screws
pulled out of OSB. Screws attached to rafter were not withdrawn.
March 19, 2007 - Improved rig spreads load onto mounting foot better.
Tile Attach. #2- Attachment of file attachment into aluminum plate and 15/32" OSB.
Peak load observed at 851 Ibf. Failure due to screws pulling out of OSB, deformation of
the mounting plate was observed.
Flash/Rafter- Attachment of flashed slider into a Douglas fir rafter through 15/32" OSB.
Peak load observed was 1693 Ibf.
Results:
Per the above cited various test conditions, the tile roof attachment exhibited the least
amount of pull out capability. In the downward direction 62 sandbags were used totaling
3,215 pounds. The total area of the array was 61W, yielding a load of 50.4 PSF. After
30 minutes the deflection was stabilized at 0.890 inches. The entire array remained intact
and no signs of failure were observed.
In the upward direction 62 sandbags were used totaling 3,213 pounds. The total area of
the array was 63.8ftz, yielding a load of 50.4 PSF. After 30 minutes the deflection was
stabilized at 0.950 inches. The entire array remained intact and no signs of failure were
observed.
Conclusion:
The SRS mounting structure with the tile attachment method exhibited the least amount
of pullout capability but was able to withstand a static load of 50 PSF in both the
"downward" and "upward" directions for 30 minutes with no visible signs of failure or
prolonged deformation. It is therefore concluded that all other tested attachment methods
are capable of withstanding the industry wide acceptable limit of 50 PSF.
Sincerely ~q0 REGjs
'40
G
ey 33527:
Licensed Profes onal Engineer 4 '
SHARK
TB2007.9.20-1
To: Sharp Certified Installers and Customers
From: Jason Bobruk, Manager of Product Planning
Technical Bulletin
Subject: UL listed integrated Grounding for the SRS (Solar Racking System)
This bulletin shall serve as a reference for installers, customers, and inspectors
with questions concerning the integrated grounding method using Sharp's SRS
(Solar Racking System).
Topics covered include:
• Installation guide and grounding method review
• Listed modules and SRS parts for integrated grounding
• Labeling previous existing inventory
• UL standard 1703 review
• UL testing review
Sharp's SRS installation guide, version SESG-SRSUL-070629 (found on the
back page), describes the proper way to install and ground the solar array. This
manual is supplied with the SRS parts that are UL listed for integrated grounding.
Page 31 from the manual, shown below, describes the proper method for
grounding the SRS rails.
SHARP Electronics Corporation
Solar Energy Solutions Group
9501 Bolsa Avenue, Huntington Beach, CA 92647
~ are. k
O SHARK
Technical Bulletin
INSTALLATION 'RORK
6.15 SYSTEM GROUNDING
Accomplishing a code compliant grounding system is critical for the We operation of the system. The SRS mounting
system and the spec)fled Sharp modules are UL Listed to standard 1703. Continuous grounding of all modules and
mounting system components is achieved through the SRS mounting clips. Connect a ground wire to each rail and
continue through the rooftop junction boot to the DC disconnect and other system components.
All of the Rails in an installation shall be provided With protective earth RAIL GROUNDING
grounding wires when installed.
Note for ND-167UIY modules: ground each module and rail using a suitable UL
listed grounding device.
1. Install an outdoor rated ground lug a other suhable UL listed grounding
device, fa example llsco G8L 4087, as shown in the illustration. Connect
thegroundwire to the lug. The lug should be located on one end of each of
the mounting rails. Use the ma*ed ground hole on either end of the rail. A
UL Listed Grounding terminal constructed of tin-plated copper or stainless
steel, or steel provided with a zirx: or Beryllium coating, and suitable for
outdoor use, shall be used with the selected grounding wire(minimum 10
ANG copperwire).
2. Connecta minimum ♦10 ANG solid conductor, copper, ground wire to the
ground lug or other suitable UL listed grounding device.
3. Connectthe ground wirein thearrayfunction boxand continueto the other Usta1P32a 1'sbMessasN mrclw,e avexr
components In the system. ea<W.a~.w
o s &t o~
P~os4 \ov¢ ~5~~ ~Optbnal
cisting
~~co ground wire
egwprnem
Emmng NEC250.54
ACgroundng optional suppi memary
electrode grouncingelectrode
(lightenag protection)
Unspliced 6 AWG conductor serves as
I. AC equlpmem grounding conductor
2 DC grounding electrode conductor
31
SHARP Electronics Corporation
Solar Energy Solutions Group
9501 Bolsa Avenue, Huntington Beach, CA 92647
SHARP
Technical Bulletin
Each module in the array his fastened down by four module mounting clips, part#
AD801. This clip, referred to as the "talon clip", has sharp barbs that pierce
through the anodized coating on the module frame to make contact with the
aluminum. The talon clip is bolted to the steel rails, part# AA801 - AA805, which
are each then bonded in series to each other and to the grounding electrode as
shown in the installation guide above. This method takes the place of the
traditional grounding lug typically placed on each module and the grounding
conductor run under each module by utilizing the talon clips and rails as
grounding conductors.
Below is a picture illustrating the barbs on the talon clip that bite into the module
frame.
In the case that modules must be removed after the installation is complete, it is
important to note that individual modules cannot be removed without first being
disconnected from the power circuit. Modules on the upper most row must be
removed before the lower modules can be removed. This is because of the
design of the SRS utilizing hidden fasteners. To ensure that the grounding
conductor is the last to break, after turning off the DC disconnect, the module's
power conductors should be disconnected before the talon clip is removed. This
is a simple and safe way to disconnect the modules if the wire management
methods detailed in the installation guide on page 37 are utilized. In the event of
SHARP Electronics Corporation
Solar Energy Solutions Group
9501 Bolsa Avenue, Huntington Beach, CA 92647
~ !Ap
SHARP
Technical Bulletin
a ground fault, the module should also be de-energized before the talon clip is
removed. It is also recommended to de-energize the entire array as detailed on
page 6 of the installation guide, using an opaque cover to reduce the risk of
shock.
Currently only the Sharp Models ND-187U1, ND-187U2, ND-1871-11F, ND-181 U1
and ND-181 U2 are listed for integrated grounding. A copy of the UL certification
document is included on the last page of this document. It can also be
downloaded from the UL website at www.ul.com following the certifications
directory link.
In the future more modules will be Listed for integrated grounding. These will
include most of the ND series models. Sharp is currently involved in the listing
process with UL for these modules and will send out announcements as soon as
the process is complete. Arrays built with modules other than those shown on
the certification document covered under "Photovoltaic Modules with Framing
system" should be grounded by traditional means.
To conform to the UL listing these modules must be used with the SRS listed
parts in order to utilize integrated grounding. SRS listed parts will be shipped
with rails that have UL labels as shown in the picture below. SRS parts shipped
prior to the production of the listed parts are not considered listed. These parts
would have been shipped with rails that do not have the UL label.
Arrays built with SRS parts shipped with rails that do not bear the UL label can
not utilize integrated grounding. Traditional grounding methods should be used
for arrays built with these parts.
SHARP Electronics Corporation
Solar Energy Solutions Group
9501 Bolsa Avenue, Huntington Beach, CA 92647
SHARK
Technical Bulletin
Labeling previous existing inventory
Sharp maintains strict control over the manufacturing of the UL listed parts to
ensure the material and production quality is maintained to both Sharp internal
and UL standards. Parts that do not meet these criteria can not bear the UL
label and can not be used. While all SRS parts produced in the past and just
prior to the listed parts have been built to these same standards, SRS parts that
were sold without the UL labeled rails are not considered listed parts by UL, and
can not be labeled as such. This means that current, unlisted inventory held by
our customers can not be labeled for integrated grounding, and must be installed
using traditional grounding means.
UL standard 1703 review
UL Standard for Safety for Flat-Plate Photovoltaic Modules and Panels, UL 1703
was standard originally developed for modules. Since the SRS is dependant on
the module frame, the SRS becomes an integral part of the array assembly, and
the module becomes part of the SRS assembly. Because of this unique design,
the module and SRS can be considered one "system". We have worked closely
with UL to include this in the scope of UL 1703 and this "system" is what is listed
for integrated grounding. This is one reason why it is important to realize that
each module and dependant SRS part must be listed for this "system" as detailed
in the previous sections of this bulletin.
UL testing review
In order to list this new type of system under UL 1703 and utilize integrated
grounding methods, many rigorous testing and evaluation procedures were
performed to ensure the product would meet UL standards to be safe and
reliable. Below is an excerpt from the listing report detailing the tests that were
performed on both the SRS parts and modules.
SHARP Electronics Corporation
Solar Energy Solutions Group
9501 Bolsa Avenue, Huntington Beach, CA 92647
The following tests were conducted.
Mechanical Loading Test
Bonding ?ac: integrity Test before 7117a Fault Current Test
?ROT-CTIC- EARTHING TRAC- ART3 FAULT CUZR3N^ TEST:
Bonding Path Integrity Test after Earth F=_41- Current Tes-
Bonding Path Integrity Test before Humidity Freeze Cycling
=idity Freeze Cycling
Bonding Path integrity Test After Humidity Freeze Cycling
ZINC COATING THICQdESS MEASUREMENT (X-RAY TEST PETSOD)
On formed AD-501 clips with grsanding points.
CO3ROS~T ATKOS?3-RE TSSTS (see Test Record 2 fox details):
Sat= Spray.
2. Y..eist Carbon Diatiide / Sulfur Dioxide.
Tae -est methods and results of the above tests have been reviewed and
fc,und in accordance with the requirements in -he UL Standard for Safety for
Flat-?late ?he-ovoltaic Mcdoles and Panels, UL 1703, Third Edition, Dated
March 15, 2002 with revisions through and Jncluding Jnae 3n, 2004.
SHARP Electronics Corporation
Solar Energy Solutions Group
9501 Bolsa Avenue, Huntington Beach, CA 92647
QIGUX160673 Photovoltaic Modules and Panels
Photovoltaic Modules and Panels
SHARP CORP SOLAR SYSTEMS GROUP E160673
282-1 HAIIKAMI
KATSURAGI-SHI, NARA 639-2198 JAPAN
Photovoltaic modules, Models SAPC-80, SAPC-123, SAPC-165, SPAC-1655, SAPC-160, SAPC-170, SAPC-175,
SAPC-185, SAPC-205, NE-K325U1, NE-QSEIU, NE 80EIU, NE-800E, ND-QOE2U, NO L3E1U, ND-N6Ei U, NE-K125U2,
NE Q5E2U, NT RSE1U, NT-SSE1U, NE-LOEW, NT-85EIU, NE 165U1, NT 185U1, ND-167U1, ND-NOECU, ND-70ELU,
ND-70ERU, ND-160UIZ, NT-17503, NU-SSE1U, NU-18501, NU-RSEIU, NU-175U1, NU-SOE1U, NU-180UI, ND-167U3,
ND-160U3, NT-18BU1, NT-190U1, NT-185UZ, ND-205UI, ND-6AE1D, ND-60RUi, ND-62RU7, NE-165US, ND-167US,
ND-205US, ND-21001, ND-208U1, NO-20001, ND-167U3A, ND162UI, ND-L3EJE, L3EJEA, ND-N2ECU, ND-72ELU,
ND-72ERU, NE-170U1, NE-80EJEA, ND-6AE1DA, NE-165U2C, ND-L5E1U, ND-6KEIDA, NT-18001, ND-187Ui, ND-
181U1, NE-160U1.
Models ND-20BU2, NO-208U1F, ND-20002, ND-20001F, ND-16702, ND-167U1F, ND-16202, NO-162U1F, ND-187U2,
ND-18102, NO-62RU2, ND-187U1F, ND-181UIF, ND-62RU1F, ND-125U1F, ND-L3EJEF, ND-N2ECUF, ND-72ELUF, ND-
72ERUF, ND-6KE1DF, ND-6LE1DF, ND-216U2, NO-192U2, ND-185U2, ND-6KE1D2, ND-123UJ2, ND-123UIF, ND-
M8EUZB,ND-N8EUZB, ND-P3EUZB, ND-PSEUZB, ND-Q2EUZB, SAPC-162, ND-167U1Y, ND-162U1Y.
Photovoltaic Modules with Framing system, Model SRS187 - Listed for use with the following UL Listed Photovoltaic
modules as follows: Sharp Model ND-187U1, ND-187U2, ND-187U1F, ND-181UI or ND-i81U2.
Last Undated on 2007-08-21
Q =f 7 Notice of D' claimer Pace T
Coovriaht n 007
Underwrites
Laboratories Inc
The appearance of a company's name or product in this database does not in itself assure that Products so identified
have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be
considered to be Listed and covered under UL's Follow-Up Service. Always took for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following
conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirely and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted
material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright p 2007
Underwriters Laboratories Inc.@"
An :n0epennertl rl7en ?ali0n wnr n!cg Said, wC~etl 11;r intopr:l 1. ni~P. ,alto and fnt1Y(leu^ge
POINTS TO CHECK WHEN SELECTING THE INSTALLATION LOCATION
2.2 CHECKING THE SOLAR POWER SYSTEM INSTALLATION LOCATION
CODE COMPLIANT INSTALLATION
1. Determine the wind loads for the installation site.
Check with your local building and safety department
for the specific requirements.
2. Make certain that the roof structure can support the
live and dead loads resulting from the installation of
the PV array.
3. Consult with a professional engineer if additional
assistance is required.
4. Determine the basic wind speed from the IBC wind
speed chart (for US locations).
5. Determine the exposure category A through D (obtain
latest definitions from IBC or local building code).
6. Determine total pressure by compiling basic wind
speed, exposure and roof height. Check with Sharp
technical support if your total pressure exceeds 45 PSF.
7. Reference the chart wind speeds to determine your
design wind pressure (PSF). Determine exposure
categories A through D for various roof heights.
8. Based on the loading in step 7, make certain that the
roof structure can support the load.
9. The modules and system are UL listed to standard
1703. The UL 1703 test is performed at 1.5 times the
design load of 30 Ibs per square foot, or 45 Ibs per
square foot. The system has been load tested by
Sharp to 50 PSF. Building departments often require
a design safety factor of 1.5 or greater for structures.
The maximum structural loading listed in this guide
does not include an added safety factor.
10.To achieve maximum load capacity, use at least
the same number of sliders as modules on each rail.
BASIC WIND SPEED SPECIFIED BY IBC
IBC Wind Speed Chart
2006 International Building Code-Basic Wind Speed (3-second gust)
11
Location Vmph (m/s) 1. Values are nominal design 3-second gust wind speeds in miles per hourfm/A
Hawaii 105 (47) at 33 h.(I 0 m)aocis ground for Exposure C category.
Puerto Rico 145 (65) 2. Linear interpolation between wind contours is permined.
Guam 170 76) 3. Islands and coastal areas outside the last contour shall use the last wind speed
Virgin Wands 145 (65) contour of the coastal area.
American Samoa 125' (56) 4. Mountainous mrrain,gorgesacean promontories and special wind regions
shall be examined for unusual wind conditions.
PV !p,
✓ a,
• INSTALLATION WORK
6:3 INSTALLING THE,OPTIONAL FhASHWGS
Flashings can improve water and ice management on
the roof by directing the water around the rail slider
assembly. It is intended for use in new construction, re-
roof, and in locations with significant precipitation. The
flashings are installed under the standard slider assembly.
Each flashing is similar in size to the slider assembly. The
flashing has a large flange around it's perimeter to allow
for integration with the surrounding shingles. There are
3 alignment marks on the flashing and identification for
the orientation of the part.
1. Confirm the locations of each standard sliderassembly.
Follow the same rules for installation as the slider foot.
The flashings located on the bottom rail (close to the
eave), should be aligned with the chalk lines created
in the roof layout. Flashings used to support the center
rails should be centered on the rail line. The flashings
located at the top rail (close to the ridge), should have
minimal exposure beyond the rail.
Rafter center line
Bottom edge of the
modules layout line
Bottom edge V
ofsliderfeet
layout line 2. Dry fit the flashing in the location marked for
installation. Use a utility knife to cut the surrounding
shingles to assure a flush and "water resistant fit.
Install flashing over a layer of shingles to insure water
resistance.
Center center line aaeers
/ mark
Rant edge aligns win
Aderfeer I,ma line
The arrow on the flashing should point
down to the eave side. Install flashing over a layer of
shingles to insure water resistance.
3. Invert the flashing, peel off the protective backing
paper and apply a bead of roofing silicone along the
top and sides in the flange area. Leave the bottom
flange clear for water drainage. When shingles are
cold, they become brittle and are difficult to work
with. Use a putty knife to lift the shingles and slide in
the flashing.
Bead of
silicone
rI///
4. Apply a bead of silicone on the top and sides of the
flange that contact the surrounding shingles. Press
the area to create tight seal.
Bead of roofing -
silicone (under shingles,
on top of flashing) ,
5. Peel off the backing paper from the standard slider.
Place the standard slider assembly on the flashing and
secure with four (XA58) 110mm flashing screws.
23
a BASK FED
bl~~k
~n S'~~vKF
BY a,1 e i
PHOTOVOLTAIC
SYSTEM
r
D.C.
DISCONNECT
0i9 04- of')<,C•~VIrc'
NIN
G
ELECTRIC SHOOK GUARD
TEE DC CONDOCTODS OF
TDIS PDOTOYOLTAIC SYSTEM
All DNODODNDED AND MAY DE ENERGIZED
ELECTRIC =$a UMB IF A
SOm alluS INNu f1ODmty
$Boom,ClNCCTCCS w BE
mallooED i Emmw
C' il\
i hyer-~e(' S
~~L+f c1
lasf~ L
~IaC~rc~S
DC ftral lers
ONeratleR Current ARC
Oneratin! Voltave YRC
maximum System voltage -_YNC
Short Circuit Current ANC
OV) Ihv<r- zr(ti)
Gln 111V:r~o~Sl
Maximum A ®~nt ®nsrattnC m -
YAC
OAeretlMl AC V60919
wwMsmfib
111112111111M CINNENTINN
2N UT R1LUei1TE
Ton N/E2N2NENT IMN
wiurws
TERMINALS SN ROTA TO LINE AN
LIAR CiiES MAY BE ENERC1tEB IN
TH OPEN P SITI N
A!, W4-'-n pc ne l
n'2 ~ f-:' PV
b
#
F
~ ~ In C
In m
p p p py
g
pp
m
D
~
P I
on
G1
.
pN
3
,
~l C
m
F7 o
D
P
L O
f7 t7
.
C
O
0 CA
Q
L
1
N
mO
G
SQ
d l'1
GG
S
.
RR} SS
W
C
o
m x
m
m
$$5... s
n
m uo
O
0
+
..1
C.
0
O
C.
O
l
~j
C
:5
a
m
n
i
w
9
-
YI
> i
+
$ a
C
D
p
3
W
g
a
S O
3
.
Q
c'~
o
41
0 0
a
>y
ro
°S
Q N
~ ms
~ N
Z
N.<
!A.
O m
m ~ 1~1 N o ~
1101
00
IOD
H 1~ xY! 0 0, OD
to
' CITY OF WHEAT RIDGE 1
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office ' (303) 235-2857 Fax
INSPECTION NOTICE
Inspection Type:
Job Address/Permit Number:
a~0
❑ No one available for inspectio
Re-Inspection required: Yes
When corrections have been mad c I
Date: Inspector: _
DO NOT REMOVE
for
" , City of Wheat Ridge
Residential Mechanic PERMIT - 081150
rooor
PERMIT NO:
081150
ISSUED:
10/03/2008
JOB ADDRESS:
3010 JAY ST
EXPIRES:
04/01/2009
DESCRIPTION:
Install EPA
Archgard 1600 woodburning insert
CONTACTS
owner 719/322-4131 Marcy Mazzetla
gC 303/935-1617 Ronald Florez 02-2421 Flores Heating & Gas Works
PARCEL INFO
ZONE CODE: UA USE: UA
SUBDIVISION: 0508 BLOCK/LOT#: 0/
FEE SUMMARY ESTIMATED PROJECT VALUATION: 1,800.00
FEES
Permit Fee 82.16
Total Valuation .00. F7~jDZ~
Use Tax 32.40
TOTAL 114.56
Conditions:
Must comply w/ 2003 IRC & 2005 NEC.
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable
ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all
measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this
application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other
applicable Wheat Ridq Ordi ances~ for work under this permit. Plans subject to field inspection.
1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the
State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable
ordinances of the City.
2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration
date. An extension may be granted at the discretion of the Building Official.
3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no
changes have been or will be made in the original plans and specifications and any suspension or abandonment has not
exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall
be paid for a new permit.
4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive
written approval on inspection card before-proceeding with successive phases of the job.
6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor
an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation.
eld inspections.
All plan review is su~je Ilk
Signature of Chief Bull ng ficial date
INSPECTION REQU ST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855
REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
oFw"~r~ City of Wheat Ridge Building Division
m 7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 " Fax: 303-235-2857
c o Inspection Line: 303-234-5933
OCORP~
Building Permit Application
Property Address: 3D (p J p, f
Property Owner (please print): C C,,` CL,~
Mailing Address: (if different than property address)
Address:
Date: py3T
Plan
Permit
FJ O''"
ceo
Phone:
goa 1~
State, Zip:
Contractor C To
Contractor License Q a a YQ I Phone: EA----a, , Q i S
Sub Contractors:
Electrical City License Plumbing City License Mechanical City License
Company: Company Company:
1,31
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: Approval:
of space (description): Construction Value: $ /9,0,D
Use
Use of par (work f~ (as calculated per the Building Valuation Data sheet)
r- Plan Review (due at time of submittao: $
Sq. Ft./L.Ftadded: Squares BTU's Gallo s Amps
OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B_C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to Id inspection.
CIRLCE ONE:: IJJOWNER) (CONTRACTOR) or PERSONAL REFIRE NTATIVE of t(OW~NER) (CONTRATOR)
PRINT NAME: I\ i SIGNATURE: -0-r~ 9 oft tLa9'iin-a_) Date:
DEPARTMENT USE ONLY
ZONING COMMENTS:
Zoning:
Reviewer:
PUBLIC WORKS COMMENTS:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer:
OCCUPANCY:-
FIRE DEPARTMENT:: ❑ approved w/ comments ❑ disapproved ❑ no review required Bldg Valuation:
:HALET-16001 I WOOD I NS -t P
ORS & INSETS BRING IN THE NEW
High efficiency from your old wood fireplace.
„w
a:
luwet etnusluiin.
ejack cast Door & optional
The Chalet 1600 insert offers a choice of two decorative surrounds'to finish off most ;
Black Fan Inset -
'
fireplace openings and your choice of black, gold, or bushed nickel doors> The firebok. '
is brick lined and uses two durable lightweight ceramic baffles positioned above, three
stainless steel secondary combustion heat tubes. As a homeowner you"will appreciate the
single level- air control handle that regulates the fire to allow an overmght,burn and the
glass will stay clean longer due to our excellent airwasb sysle ,
SPECIFICATIONS
Optional Brushed Nickel-Plated Door
Optional Brushed Nickel Fan Inset
MINIMUM FIREPLACE OPENING SIZE
Doors and surrounds are additional
FRONT VIEW WITH STANDARD SURROUND WIDTH & DEPTH & 243/4" x 16" x 19"
Fan Housintl comes standard with screen front
HEIGHT (629MM X 406MM x 483MM)
40"11016mm)
46"0168mm) for EPA EMISSIONS 2.88 GRAMS/HR
CLEARANCES
large surround
,
SEASONED CORDWOOD 65,000 BTU (19,049 KW)
5
s XSr
\
RATING
APPROXIMATE HEATING 800 - 1500 SO FEET
74.3 - 139.4 So METRES
s c AREA
_
DURATION OF LOW, FIRE 6 - 10 HOURS
o
LOG LENGTH 18' (457MM)
.mom
;
- ~ =
-
STOVE BODY WEIGHT WITH 300 HIS (136 KG)
V ,
DOOR AND SURROUND
v
.
i
: `
•
.ac _
-
^ •
SURROUND PANELS
q Cr
STANDARD (W X H):. 40",(1016MM) X 28" (711 MM)
E
LARGE (w X H) 46" (1168MM) x 32" (813MM)
TOPVIEWWITH ARCHED FIS 42"W-:(1066MM)x27"
'-LEAP- NCE TO COMBUST
IBLES STANDARD SURROUND (687MM) AT EDGE X 307178"
(784MM) AT CENTRE
23%`
DE WALL TO INSERT A = 16.26 /412.75mm (603m1)
.i TESTED AND APPROVED
- - -
" H62mm) to TO CANADIAN AND AMERICAN STANDARDS,
)P OF INSERT TO BOTTOM OF MANTLE
UL 1482-96/ULC 5628-00
= 26"/660mm F = 6"/152mm
al _ LIFETIME WARRANTY ON SPECIFIC ITEMS
28"/711mm 8"/203mm
'
'
32"/813mm 12"/305mm
_
. F
, PLEASE . ASK YOUR DEALER FOR DETAILS
DE OF INSERT TO C =8.75"/22mm
CONSULT' OWNERS MANUAL FOR MORE INFORMATION OR
ANTLE LEG
f VISIT OUR WEBSITE BELOW
:ARTH EXTENTION FRONT D =
{ r \`•)s"a
1NADA 181/450mm USA = 16 /400mm
` \
Surround depth is adjustable
EARTH EXTENSION SIDE E =
frGn112711 UI6 aoa Io 15vr1H
SNADA = 811/200mm USA = 811/200mm
(392.m) from the back of the unit
Center offlue to rear of insert
'
raras.,e is 6" (152..)
MARCHGARD.
IIRF GIPCE 'RearITS
www.archgard com
"'; ~.,<~,... 't', "..'
~" "
~ A
.... ~ ~ r' CITY OF WHEAT RIDGE
pr'r~ Building InspElction Division
!V' (303) 234-5933 Inspection line
(303) 235-2855 Office' (303) 235-2857 Fax
INSPECTION NOTICE
o~&-L/
InspElction TYPEl: -2",."...,-{'
Job AddrElss/PElrmit NumbElr: -:!O(r') .:; fA '7 "7 T
<j'Z. cro-l
/,,-':7W
<P1"''''r
('''/:oO ,__/r
I' ,0+"-" ~ i?"" r "'.... ./
Y-c. t",. !.J. --'/ P ~~d
D No one available for inspection: Time
Re-Inspection required: Ye~~ /;.
AM/PM
* When corrections have been made, call for re-inspection at 303-234-5933
i' _-~-. _---:;..:?'
I /. ~<~:>~
Date~ I ::;('11 r~ Inspector: / ~) C'.r-'---Z.u/
i I //
./
DO NOT REMOVE THIS NOTICE
~ A
....~ ~ r' CITY OF WHEAT RIDGE
pr'r)l";jj Building InspElction Division
~ (303) 234-5933 Inspection line
(303) 235-2855 Office' (303) 235-2857 Fax
INSPECTION NOTICE
InspElction TYPEl: k,'::
Job AddrElss/Permit NumbElr: 3010 Jfi y fT 08>""V!? V
,
~~I/ OU/N,"~( A~.4}1;'/~(ID~ TV bE! o/J
M;:t- 1 00 /H/'5JJf:el/v#
D No one available for inspection: Time /o:~ AM/PM
--"
Re-Inspection required: ~ No
* When corrections have been made. call for re-inspection at 303-234-5933
Date: b/2t//"-J9 Inspector: .;~;
DO NOT REMOvE THIS NOTICE
-----~_..__._.~._------~--------~---_._-----_._------_.~----_._-
~u~
~
City of Wheat Ridge
Residential Roofing PERMIT - 080484
PERMIT NO:
JOB ADDRESS:
DESCRIPTION:
080484
3010 JAY ST
Remove and replace 28 sqs.
ISSUED: 05/19/2008
EXPIRES: 11/15/2008
of asphalt shingle roofing
gc
*** CONTACTS ***
303/466-0161
Bernie Reitz
01-9543 Reitz Roofing, Inc.
** PARCEL INFO
ZONE CODE:
SUBDIVISION:
**
UA
0508
USE:
BLOCK/LOT#:
UA
0/
Permit Fee
Total Valuation
Use Tax
** TOTAL **
ESTIMATED PROJECT VALUATION:
FEES
144.70
.00
89.21
233.91
4,956.00
** FEE SUMMARY **
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable
ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all
measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this
application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other
applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection.
Signature of contractor/owner
date
1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the
State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable
ordinances of the City.
. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration
date. An extension may be granted at the discretion of the Building Official.
3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no
changes have been or will be made in the original plans and specifications and any suspension or abandonment has not
exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one {1} year, full fees shall
be paid for a new permit.
4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
5. Contractor shall notify. the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive
written approval on inspection card before proceeding with successive phases of the job.
6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor
an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation.
All plan review is subject to f" d inspections.
date
INSPECTION REQUES, LINE:
REQUESTS MUST BE MADE BY
(303) 234-5933 BUILDING OFFICE: (303) 235-2855
3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
~u~
~
City of Wheat Ridge
Residential Roofing PERMIT - 080484
PERMIT NO:
OB ADDRESS:
ESCRIPTION:
080484
3010 JAY ST
Remove and replace 28 sqs.
ISSUED: 05/19/2008
EXPIRES: 11/15/2008
of asphalt shingle roofing
*** CONTACTS ***
303/466-0161
Bernie Reitz
01-9543 Reitz Roofingl Inc.
* PARCEL INFO
ONE CODE:
UBDIVISION:
**
UA
0508
USE:
BLOCK/LOT#:
UA
0/
SUMMARY * *
ESTIMATED PROJECT VALUATION:
FEES
144.70
.00
89.21
233.91
4,956.00
:Permit Fee
<"Total Valuation
Use Tax
,** TOTAL **
omments:
Nails per shingle required
Ce and water shield required
ID-ROOF inspection required
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable
jordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all
measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this
application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.Cl and all other
applicable Wheat Ridge Ordinances, for work under this permit. plans subject to field inspection.
. _~L.____ /<?..:V~------- ,-")//:7/00
Signature of contractor!owner~ ~ date
This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the
State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable
ordinances of the City.
This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration
date. An extension may be granted at the discretion of the Building Official.
If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no
changes have been or will be made in the original plans and specifications and any suspension or abandonment has not
exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall
be paid for a new permit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive
written approval on inspection card before proceeding with successive phases of the job.
The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor
an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation.
All plan review is subjec t eld inspections.
date
INSPECTION REQU .T LINE: (303)234-5933 BUILDING OFFICE: (303}235-2855
REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of Wheat Ridge Building Division
7500 W 29th Ave., Wheat Ridge,. CO 80033
Office: 303-235-2855 * Fax: 303-235-2857
Inspection Line: 303-234-5933
Date:
Plan #;
Permit #; tt!lJ-0.
Building Permit Application
Property Address: "3 0/ () ..::J,....,. '7 S -f. '
Property Owner (please print): \) E t"; \~f I ~ M Q ",{ S '" .... E-2 '7 Phone:? - '5 C;~/- ~ /7 r
Mailing Address: (if different than property address)
Address:
City, State, Zip:
Contractor: ~E
+'2
K-P)
~
~~'C"jo
Contractor License #:
Phone:
3-<7'bC?- C>/G /
Sub Contractors:
Electrical City License #:
Company:
Plumbing City License #:
Company
Mechanical City License #:
Company:
Exp. Date:
Approval:
Exp. Date:
Approval:
Use of space (description):
Description of work:
dJ- 121 / 7/0
7J,y..en/--'c:>-d5
Sq. Ft./L.Ft added: Squares
Construction Value: $
(as calculated per the Building VafuationIJ:ata sheet)
Plan Review (due at time of submittal): $
BTU's
Gallons Amps
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback .distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and. that I assume full
responsibility for compliance with the lJIJheat Ridge Building Code (LB.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to field inspection.
CIRLCE ONE:: (OWNER)
PRINT NAME: . J / ;.,.,
(CONTRACTOR) or
c;,o/cbr..
PERSONAL RE
SIGNATURE:
ER) (CONTRATOR)
Date:""'/7-~
DEPARTMENT USE ONLY
ZONING COMMENTS:
Zoning:
Reviewer:
PUBLIC WORKS COMMENTS:
Reviewer:
BUILOING DEPARTMENT COMMENTSn
Reviewer: ~
FIRE DEPARTMENT:: D approved wI comments 0 disapprovec! 0 no review required Bldg Valuation: $
~
OCCUPANCY
IJ'V
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING INSPECTION LINE - (303-234-5933)
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80033 - (303-235-2855)
Building Permit Number: 16675
Date: 1/23/2004
Property Owner: DEBBIE MONTGOMERY
Properly Address: 3010 JAY ST
Contractor License No.: 19312
Company: Deer Creek Plumbing, Inc.
Phone: 274-8313
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Phone: 697 5883
1 hereby certify that the setback distances proposed by this permit application are accurate, and
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate: that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B,C.) and all other applicable Wheat Ridge ordinances, for work under this permit.
(OWNER)(CONTRACTOR) SIGNED
DATE
Description:
INSTALL 40 GALLON GAS WATER HEATER
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
$300.00
$30.55
$0.00
$3.60
$34.15
Total:
Use:
BUILDING DEPARTMENT USE ONLY
17w;~t-~.,."f,';,<\:,;o/b:."~':ff~.<4'f~..W:-l
~t1lng~omro'en;~Jl
Approval:
Zoning:
~~''''''''f~
,J;JJ . 10g$_ml!)'~lhl!1,
Approval:
ef~~1im:ro'lrdt's~
Approval:
Occupancy: Walis :
Roof:
Stories:
Residential Units:
Electrical License No :
Company:
Plumbing License No: 19312
Company :Deer Creek Plumbing, Inc.
Expiration Date: 4/22/2004
Approval: OK/KS
Expiration Date:
Approval:
SIC:
Sq. Ft.:
Mechanical License No :
Company:
Expiration Date:
Approval:
This permitwas issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning
Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City.
This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned fOf a period of 120 days.
If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new pennit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceediin with successive phases of the job.
T e is n of a ermi r the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the
provi ns f t~ codes or any other ordinance, law, rule or regulation.
(1)
(2)
(3)
(4)
(5)
(6)
~
Chief Building ~pector
Please sign Terms and Cooditioos 00 reverse side of page,
DEf'8RTMENTOFf'LANNING AriiDoEvELOPMENT .
. 'BUILDfNGjf\fSR$9TiQN'pj\j~fQN~23!j?i855
CITY OF vvHEA T RIDGE .
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Building f'ermit Number:
Date:
}-15~OLj
Property Owner:
Property Address:
Contractor License No. :
A PPL\ C.F\T ION
b\ 'e ~
160\0 0~
\0.3\'2...
Company: lX:.e...Q... ~
Phone: S- e)rlit ~ 31 g
Plkxj .
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Construction Value:
Permit Fee:
Phone: \o"\'I-S8'83
30 0 CO
'3,0 'S:.s ''-.''-
'34' 0
I hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibmty for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable heat Ridge rdi ances, ,or work undertliis pennit.
Use Tax:
(OWNER)(CONTRACTOR) SIGNED
Total:
DATE
Use:
\'-;~Y4<l 'if'c0 Wi,\
\ BUILDING DEPARTMENT USE ONLY
SIC:
Sq.Ft.:
Description:
~OJltl!g~t;JJ.IJ1Jn~pJS;J
Approval:
Zoning:
!?!I..JIQ!!l~o,;...!!!!!.~..!1!;cS~
Approval:
g!!ePs.."W:OJ'!.'!i~.J!1!!1el1.!5
Approval:
Occupancy: Walls:
Roof:
Stories:
Residential Units:
Electrical License No :
Company:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval:
Expiration Date:
Approval:
Expiration Date:
Approval:
(1)
(2)
(3)
This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and 10 the Zoning
Regulations and Building Code of \lVheat Ridge. Colorado or any other applicable ordinances of the City.
This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a periOd of 120 days.
If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit
No wcrk of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty.four (24) hours in advance for aU inspections and shall receive written approval on inspection card before
proCeediing with successive phases of the job.
The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of the building codes or any other ordinance, law, rule or regulation. _
(4)
(5)
(5)
Chief Building Inspector
\L\
BUILDING DEPARTMENT
(303) 235-2855
CITY OF WHEAT RIDGE
* *
Correction Notice
Job Located at .3 0 (0 Ua.- '7 s::!
{
I have this day inspElcted this structure and these prElmisEls and
havEl found thEl following violations of City and/or StatEl laws gov-
ernin'lt,m mfLEl: ;/, .1-
La. If, ;J N. Urnf,r dP GJ'vrje
9 (17JlJicb 5'r.ltt>r1- ,)/74'..-7 t/aJl? ~
r/'">r'f.t"
-z) Ph /J,' rA .r;ro-rf- Hr ial"1" ,dp.>r ~
Y/tO NO-/- cJ(.7e11 bJo-r. ynjd 7(II7"'c,<
(l.("'-Il ()<".-,,f.,,pj/(J/1..
You arEl herElby notified to correct the forElgoing violations.
WhEln corrections have been made, call for inspElction.
DatEl
?
DO NOT REMOVE THIS TAG
FORM WR6-22
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: 95-1484
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date :7/24/95
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner: MONTGOMERY DEBORA L
Property Address: 3010 JAY ST Phone: 274-8313
Contractor License No. : 18271
Company: CENTENNIAL ROOFING Phone: 238-5557
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Construction Value:
Permit Fee:
Plan Review Fee:
Use Tax:
$2,080.00
$54.00
$0.00
$31.20
$85.20
I hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full respo . y for campI" . e with the Wheat Ridge Building
Code (U.B.C.) and all other applicable at Ridge or. andes, for work under this per it.
(OWNER)(CONTRACTOR) SIGN DATE~:.?'" ';?
Total:
Description:
REROOF
BUILDING DEPARTMENT USE ONLY
~
Approval:
Zoning:
~
Approval:
~1IIi11!1t'iRmI _UI--",~I~
Approval:
Occupancy: Walls:
Roof:
Stories:
Residential Units:
Electrical License No :
Company:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval:
.~
Expiration Date:
Approval:
.lllE1a.___MU"r,ml~-1
Expiration Date:
Approval:
(1)
(2)
(3)
This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning
Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City.
This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a period of 120 days.
If this permit expires, a new permIt may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceediing with successive phases of the job.
The i suance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of th build' g codes ~ ;ther ordinance. law, rule or regulation.
(4)
(5)
(6)
ief Building Inspector
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION
IJ1~J)
. DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number:
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE Date: 7- ~ y;; ~ S-
7500 WEST 29TH AVENUE j/;e: /':?'
WHEAT RIDGE, CO 80215
Property Owner:
Property Address:
Contractor License No. :
Company:
#'?"'''''' ./-frv A-? ~p2.? '
30/ D -:::s C><-. b~. ~,,~ ~ f/l./d'5>C
/ Z!6;;<./'7
/8'2"7/,
/'h"u-l-4....--.c> ~p '- {Z '" 1/;'" /'
Phone: -;? 77"- ~;;'3/ 5
Phone: :2:5 5"- SSS7
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Construction Value:
2,0 [?O
~. o--e-
I hereby certify that the setback distances proposed by this permit application are accurate, Permit Fee:
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate: that I have read and agree to abide by all conditions printed on this Use Tax:
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat ~idge ordina~ce or work under this p~rmit.
~. ~:
(OWNER)(CO~lRACTOR) SIGNED t{;7' ~ ~ <? /" """,,",,,,e?<DATE ;; ';;? 7.l
Description : ~r,P l"? :5 --r A.(, S~ >? iJ<:> <....J A> S'L ,,"'..-. ? GA:' J
BUILDING DEPARTMENT USE ONLY
$0.00
ZIi'iiiilijlii1,:l'l-~"~IDDUl!'ii'fiiifi
Approval :
Zoning:
~
Approval :
~
Approval:
Occupancy: Walls:
Roof:
Stories :
Residential Units:
Electrical License No :
Company:
Plumbing License No :
Company:
Mechanical License No :
Company:
Expiration Date:
Approval:
ill ~_!BIII
Expiration Date:
Approval:
ill _!!!!iigRgllit~!r~1
Expiration Date:
Approval:
ill -lillRI-
(1)
(2)
(3)
This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning
Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City.
This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a period of 120 days.
If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit.
No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
Contractor shall notify the Building Inspector twenty.four (24) hours in advance for aU inspections and shall receive written approval on inspection card before
proceediing with successive phases of the job.
The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of the building codes or any other ordinance, law, rule or regulation.
(4)
(5)
(6)
Chief Building Inspector For Mayor
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MA VOR
CALL: 234-5933 24 HOURS PRIOR TO INSPECTION