Loading...
HomeMy WebLinkAbout3363 Jay Street&V (10 3263 INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Occupancy/Type Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric " Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing LL 11-4Sp O CoY**Y) /2,,c Final Mechanical ^moi I v1( ^j V Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits - Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather 3 The City of Wheat Ridge,1 T it arty Form Check List Property Address Permit Number - Permit Issued Date Owner Information Property Owner Information Property Owner Address 'Z�In) = -� Inspector Infor ation Inspection Company r4i" Inspector Name iq Inspector Contact info. ' - 0 Inspector Statement and Acknowledgement * I hearby acknowledge the roof I am inspecting is 6/12 or over all roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufactur is recommendation an i -- ; 0 Inspector: Date: Pro rt Owner Statement of Acknowled ement *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -pa ction company to perform my roof inspection in lieu of the City of�geer i g i g Division inspection. Propery OwnA- ent: Date: 4�7 This original document,as well as the roofing check list, must be submitted to the Chief Building Offical within seven days of the final inspection. Drop off in person Submit via Email Permit counter 2nd floor Kcooikaci,wheatridge.co.us 7500 W. 29th Ave Wheat Ridge CO 80033 Drafted Date: 7/26/17 Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Mid -Roof Ro f inspection 0 N/A P Pass Ci Fail Cl N/A Xpass 0 Fail Structural roof components a N/A >17Pass 0 Fail Verify that no more.than 2 layers of shingles exist * N/A m Fail Flashing for roof and walls ,Pass o Pass Q Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) N/A o Pass 0 Fail Verify sheathing nail pattern ( See policy & Proceedures) N/A c Pass a Fall Crickets and saddles where needed 0 N/A _'Vr'Pass l? Fall Verify B vent must have boot same gauge as pipe O N/A Pass 0 Fall Verify vent Caps is N/A xPass Q Fall Verify no flashings are damaged or rusted p N/A 'Pass a Fall Step flashing shall be min. of 4x4 piece per shingle M N/A X, Pass �eea'ooPass a Fail Verify scuppers allow for proper drainage p N/A Psss 0 Fail Ice and water shield 2' in heated wall spaces a N/A -Air-Pass El fall Underlayments must follow 2012 IRC / 2012 IBC A N/A Pass la Fail Verify roof slope for proper drainage 0 N/A Pass 0 Fail Dripedge shall have min of 2" overlap 0 N/A >-Pass 0 Fall Dripedge should extend down min 2" past roof deck Q N/A 'A&_ Pass 0 Fail Dripedge shall be mechanicaly fastened 12" OC A 0 Pass 0 Fall 90 LB roll roofing shall not be applied to root slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A 0 Pass B Fail Modified Bitumen, EPDM, TPO min slope 1/412 slope 'N/A @ Pass E3 Fail Above roof insulation R-25 N/A A Vass n Fail Below roof residential R-38 XN/A ❑ Pass o Fall Below roof commercial R-32 /yYN/A i� Q Pass 0 Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shinnies Requirements rements N/A a Pass 0 Fall Metal roof shingles shalt not be installed on slope less 3:12 N/A ca Pass 0 Fail Metal valley flashing shall be the same material as roof /A Cl Pass a Fall Metal valley flashing shall extend a min of 8" from the " centerline with a min. of 3/4 high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roots Rcluirements /A l Pass o Fall Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge inspection Check List notes Mid -Roof N= Company Name: Inspector signature: Date of Inspection: The City of Wheat Ridge Inspection Check List notes Final Roof Roof Inspection * NIA 13 Pass ❑ Fail * N/A bass 0 Fail Structural roof components Pass Q Fail Verify that no more than 2 layers of shingles exist » N/A 0 N/A „'Pass 0 Fail Flashing for roof and walls 0 Pass 0 Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) XNIA 0 Pass 0 Fail Verify sheahing nail pattern ( See policy & Proceedures) /Xi'l/A a Pass D Fail Crickets and saddles where needed a N/A XPass 0 Fail Verify B vent must have boot same gauge as pipe * N/A Pass 13 Fail Verify vent caps * N/A Pass 0 Fail Verify no flashings are damaged or rusted C] N/A Pass 0 Fail Step flashing shall be min. of 4x4 piece per shingle 0 N/A X Pass 0 Fail Verify scuppers allow for proper drainage 0 N/A XPass o Fail ice and water shield 2' in heated wail spaces M N/A XPass 0 Fall Underlayments must follow 2012 IRC / 2012 IBC 0 N/A 11'Pass 0 Fail Verify roof slope for proper drainage ❑ N/AAass a Fail Dripedge shall have min of 2" overlap 0 N/A Pass 0 Fail Dripedge should extend down min 2" past roof deck a N/A a55 0 Fail Dripedge shall be mechanicaly fastened 12" OC VNIA Cl Pass Q Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min, slope of 1:12 ` A/A 0 Pass 0 Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ,ON/A 13 Pass 0 Fail Above roof insulation R-25 /IMA/A 0 Pass D Fail Below roof residential R-38 ,A N/A 0 Pass 0 Fan Below roof commercial R-32 KNIA a Pass 0 Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection metalRoof Shingles Requirements j N/A Q Pass C1 Fail Metal roof shingles shall not be installed on slope less 3:12 N/A E2 Pass 0 Fan Metal valley clashing shali be the same materW as roof N/A 0 Pass c Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs RegUILegments N/A 0 Pass 0 Fail Clay and concrete the shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Note Company Name: Cs%® ;��� Inspector signature: Date of Inspection: City of Wheat Ridge Residential Roofing PERMIT - 201705981 PERMIT NO: 201705981 ISSUED: 08/12/2017 JOB ADDRESS: 3363 Jay ST EXPIRES: 08/12/2018 JOB DESCRIPTION: Residential Re -roof to install OC Tru Def asphalt shingles - 35 sq *** CONTACTS *** OWNER (720)339-7146 GILMORE DON DAVID SUB (303)658-0390 Troy Buskirk 110235 Red Diamond Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: R-3 / Residential SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,600.00 FEES _4* Total Valuation 0.00 >a Use Tax 201.60 PAI Permit Fee 204.30 ** TOTAL ** 405.90 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. � A t City of Wheat Ridge �. -, Residential Roofing PERMIT - 201705981 PERMIT NO: 201705981 ISSUED: 08/12/2017 JOB ADDRESS: 3363 Jay ST EXPIRES: 08/12/2018 JOB DESCRIPTION: Residential Re—roof to install OC Tru Def asphalt shingles — 35 sq I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as pames to the work to be performed and that all work tot performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original ermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett 20VO, I N From: no-reply@ci.wheatridge.co.us Sent: Tuesday, August 8, 2017 5:00 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Flagged Categories: Dane, Rejected Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 3363 Jay St.,4h at Ridge, CO 80033 Property Owner Name Don and Sue Gilmore WA �1 Property Owner Phone 720-339-7146 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Gilmore contract.pdf Contract CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Red Diamond Roofing D 110235 303-658-0390 7000 N. Broadway Suite 101, Denver, CO 80221 Contractor Email Address tara@reddiamondroofing.com Retype Contractor Email Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) tara@reddiamondroofing.com 35 9600.00 PJ Are you re -decking the roof? Does the scope of the project include a flat roof (less than 2:12 pitch)? Does the scope of the project include a pitched roof (2:12 or greater pitch)? How many squares are part of the pitched roof? Describe the roofing materials for the pitched roof: Type of material for the pitched roof: Provide any additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) No No Yes 35 OC Tru Def Duration Asphalt Complete re -roof. Re -shingling the house and work shop. Not doing the shed. 9:12, 5:12 and 3:12 pitch on the house. 5:12 pitch on the work shop. SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit 3 has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Tara Olson Email not displaying correctly? View it in your browser. 1�►� RedtUiarnond R Q Q F 11V EE Ink Ali ,mkor- Client Name: Project Manager: Address: Project Manager Phone: City, State: Zip: insurance Provider, Municipality Policy Number: Phone 1: Claim Number: Phone 2: Insurance Deductible: Email: insurance Coverage: 0 RCV ❑ ACV 0 Code Upgrade Date: Mortgage Company: Scope of Roof Work to be Completea by Kea utamon l tloonng 0 Obtain Per its and Coordinate Inspections as Necessary to Ensure Code Compliance 0 Tear Off Layer(s) of Composite Shingles Layer(s) of Wood Shake Shingles Layer(s) Other 0 Replace/ Ir 5tall Decking (1/2' OSB typically) Describe Location: 0 Install Ica 8 Water Barrier: 0Eaves QValleys 0intrusions 0 Install Pent ieter Flashing (Drip Edge) ❑Eaves ❑Rakes ❑Color: [3 Install Undf dayment: 015# Felt 030# Felt Synthetic o Manufacturer 0 Install New Roofing: 030YR 040YR 050YR OLifebme 01R e Series: 0 Closed Vail 3y with Approved Underlayment 00pen Valley with Valley Metal y r—t Color. "�� Initial: f,_t Install Stan Jaid Ridge 0Install High Profile Ridge 0 Install Ridge Vent 0 Replace Pi a Jacks 0 Replace Bath Vents 0 Replace Heater Caps And Base�� 4/ 0 Replace A c Vents OTurtle Type Vent(s) ❑Turbine Vent(s) ❑Other• 0 Replace Da naged Flashing as Required by Local Code or as Prescribed by Insurance Company's Adjuster Report 0 Paint Pipe, acks and Vent Stacks to Match Shingles 0 Existing Low Slope Roofing Type: Replace With: 0 Clean Up 4 Construction Debris and Haul Away Total Root Price Roof Upgrdes (applies only if Customer Decides to Upgrade their Current Roof System): r— i UDarade Item I Quantity I Unit Price I Unorade Cost Special ins ructions: Total Upgrade Cost to Customers D Y' By signinc this agreement the Property Owner authorizes Red Diamond Roofing Inc to represent the Property Owner's best interest in pursuit of roof replacement or repair due to storm damage. This contr ct does not obligate the Property Owner or Red Diamond Roofing Inc until the claim Is approved by the property o vner, insurance company and accepted by Red Diamond Roofing. Upon app val of claim, Red Diamond Roofing will complete the specified roof agreeable to the property owner, insurance ompany and Red Diamond Roofing Inc with no additional cost to the Property Owner except for the Insurance leductible. Insurance greed upon price will become the final contract price, and Red Diamond Roofing will receive all Insurance roceeds and supplements for work completed by Red Diamond Inc. As the Property Owner I (we) agree to all contract conditions on the front and back of this agreement. Client Signstui a Date Red Diamond ooting Inc Representative Date 7000 N ay, Unft 101 Phone: (803) 658.0390Denver, CO 0221 Please make all checks payable to "Red Diamond Roofing" l=ax: (808) 204AO67 1, 11 � A 4V City of tete: Budding & Inspection Services Division 7500 W, 2e Ave., Wheat Ridge, CO 80033 Plan Review Fee. Office: 303-235-2355 * Fax: 303-237-8929 Inspection Line: 303-234-5033 eii. 2ermitsffei.wheatridgeco.us Building er it Application Property Address. -. izy Complete plete all information on BOTH sides of this for Mailing Address: (if different than property address Address. City, State, Zi Architect/Engineer E-mail: Pane. Contractor: Contractors City License . Phone: Contract E-mail Address: Sub Contractors.* Electrical: Plumbing: Mechanical. W.R. City License # W.R. City License # W , City License # Other City Licensed Sub. Other City Licensed Sorb: City License # City License # Complete plete all information on BOTH sides of this for •.. * * Y ! . A • • A w � ipt ItlY * x e � 9 - IN,+ mount of materials to be used, etc.) r AlS { t� t.B Btu'Gallons .. Or Current owner/Occupant Don Gilmore 3363 JAY ST WHEAT RIDGE CO 80033-7438 Regarding Permit: 20110578; Install 141 x 28' shed- not heated, 15 amp service 3363 Jay ST, Wheat Ridge, CO 80033-7438 10-0FM Our Records indicate that the above noted permit was issued on 05/20/11. Our last inspection related to that permit was on 08/05/11. Please contact this office within one week from the date of this letter to update us on the status of this permit, or call for a final inspection on the property. You may call 303-234-5933 or request inspections online at www.ci.wheatridge.co.us. Information needed are permit number, property address, type of inspection and date to be inspected. If you do not contact this office, and wish to resume work at a later date, you will be required to submit a new permit application, drawings with appropriate code edition information and pay applicable fees. Incomplete or inactive permits may be reported to agencies such as Jefferson County Assessor, title companies, etc., and could affect future transactions related to this property. Thank you for your cooperation concerning this matter. If we can answer any questions, please don't hesitate to contact us at 303-235-2855, option 7. Melissa Mackey Senior Permit Technician City of Wheat Ridge 107u=# TO: Accounting Department FROM: Melissa Mackey, Building Division V\�\ z DATE: August 22 2014 Reason: Permit #201401071, for 3363 Jay Street, is a duplicate permit faxed in. Please refund 100% of fees paid. Please refund: Contractors License$ (acct 01 1 00% permit fee: $109.20 (acct 01-510-00-516) % plan review $ (acct 01-550-05-551) 100 % use tax: $68.40 (acct 01 -500-02-505) • Iff. JUL/31/2014/THU 11:46 AM RISE I i !I i 'n 4- . ... ...... . Cf�� Catd Payment V9ccMdltc*hdll**d,6hMC Doli� Pdat name. Slonawre: AEI / 1/ 114 /FRI 01.18 PM offli I PP, a 2 2 1 N WI W. M.T.WrIMM OS L IN . 'sm Building blvitton Office: $03-M-286,6 'Far. 303-237-8929 Ins poebonUm 303-234 ILEimm t• #. row IEW :IFNI I I mil r � Ti �azla Bldg ? a atlow • ow JUL/ 31/2014/THU 11:46 AM nomeDilwo 01, 4 CITY OF WHEAT RIDGE ( Building Ins a Division # • Inspection line (303) 235-2855 Off, Inspection Type Job Address Permit a r INSPECTION NO- E r— �1 CITY OF WHEAT RE for inspection: Time /,'IS AM// ired: Yes '4No ive been made, call for re inspection at 303 234 -5933 Inspector: 7, : NOT REMOVE THIS NOTICE A r CITY OF WHEAT I Building Inspection I t -2n4193d-5933Insne INSPE( IE Ix Inspection Type ,44 Job Address 5: 2 - Permit Number 114 2 E erA'1 r ,p F 4 c e 4 :2 V" Q � ❑ No one available for inspection: Time 4. / X M Re-Inspection required: No I When corrections have been made, call for re- inspection at 303 - 2345933 Date: Inspector: DO NOT REMOVE THIS NOTICE r . t` f' r: CITY OF WHEAT RIDGE Building Inspection Division (303)234 -5933 Inspection line (303) 235 -2855 Office * (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type A�° rwsy Job Address -7" 'Permit Number 11057T k } ,T{ ❑ No one available for inspection: Time AlvttW c Re- Inspection required gS = No `When corrections have been made, call for re- inspection at 303- 234 -5933 Date: Inspector: DO NOT REMOVE THIS NOTICE • . CITY OF WHEAT RIDGE opt Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office - (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type L; L Job Address s7 Permit Number ❑ No one available for inspection: Time Ali Re- Inspection required: Yes < No *When corrections have been made, call for re- inspection at 303-234-5933 Date: a y,r Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division l (303) 234 -5933 Inspection line (303) 235 -2855 Office - (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type sr` Job Address 5r Permit Number 110S A-V F_17 j96 4,e sus A1,46 A AM ign • w, ❑ No one available for inspection: Time AM4e:W_. Re inspection required: 'es. No When corrections have been made, call for re- inspection at 303- 234 -5933 Date: _6L711,1 Inspector: f DO NOT REMOVE THIS NOTICE 4' City of Wheat Ridge . Res. Accessory Struc PERMIT - 110578 PERMIT NO: 110578 ISSUED: 05/20/2011 JOB ADDRESS: 3363 JAY ST EXPIRES: 05/19/2012 DESCRIPTION: Install 14' x 28' shed- not heated, 15 amp service * ** CONTACTS * ** - owner 303/458 -807.5 Don Gilmore ** PARCEL INFO ** ZONE CODE: R -2 USE: R -3 SUBDIVISION: 0490 BLOCK /LOT#: 0/ Conditions: SS: Approved. Zoned R -2. Subject to field inspection. KC: Approved per plans and red -line notes on plans. Must comply with 2006 IRC, 2005 NEC and all applicable City of Wheat Ridge Municipal Codes. Subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain, this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this documen and /or its' accompanying approved plans and specifications. L2 0 Signature�of OWNER or CONTRACTOR (Circle one) bate 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one- half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field insp tion. Signat rsrTTISOMUS of Building Offical Date INSP REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REOU T BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of heat Ndge COM COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 « Fax: 303- 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application Property Address; 3 3 � � � a � �� Property Owner (please print): Mailing Address: (if different than property address) Address: City, State, Zip: J Conf "ractor: L6 LUZ� l'l Contractors City License M Phone: Sub Contractors Electrical. Plumbing: < � 3�� 4 (2 21 So = 9Yag City License # City License # 414 �-- -- 8% =' Descrtptior3 of work'! �3N- Sr) °~- Contract /- mlo 5e-a-" Review ee at time of submittal): I Squares 5 BTU's Gallons Amps is Sq Ft. 3g 7 $ g OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: �c a l ( VK 0 re S 7 / SIGNATURE: /G�^- DATE: � "ZONING COMJuJENTS ��LYU^d- � � ��, �Y �r rt � � � ' h � � " � � s � sF � ` S� i �' ? ��,' ✓-�, w 6 � i.; �. � OCCUPANCY r l �1 Date: 05 I II Plan # Permit # one: -�30 3 (jY Vf `60 -�' S 61dg Valuation:$ Q:;Z&9 � Residential Worksheet Address: 3 36? S'tt Zoning: Property in the flood plain? /V O Lot Size: ls )ti sq. ft. Lot Width: ft. Maximum Lot Coverage: � 0 % Proposed huprovements: House: sq. ft. Addition to House: sq. ft. Shed: f 7- sq. ft. Detached Garage: sq. ft. Proposed Lot Coverage: (Total) / 3 % sq. ft. Existing Improvement(s): House: % y $ 7 sq. ft. Shed: sq. ft. Detached Garage: P % %� q ft- / sq ft. sq. ft. Required Setbacks: FR 2 , S S 25 R J � t 1 Provided Setbacks: FR S /� S R Maximum Height: / U ft. Maximum Size: Proposed Height: / C ft. Proposed Size: sq. ft. - 2-- sq. ft. Access Notes For one and two - family dwellings, the fust 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer than 25' to any property, line, except when used as joint access for two or more lots. In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. One and two - family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. For all uses, one access point per property is permitted. Landscaping Notes For one -and two - family dwellings, one tree for every 70 feet of street frontage is required. 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance of C.O. y6'0 Street trees required: Street trees provided: How to Use this Guide Provide two sets of plans and complete the following: 1 Complete this Building Guide by filling in the blanks on page two and three, and indicating which construction details will be used. 2 Provide 2 Plot Plans (site plan) showing dimensions of your project or addition and its relationship to existing buildings or structures on the property and the distance to existing property lines, drawn to scale. 3 fill out a building permit application. The majority of permit applications are processed with little delay. The �� 4 submitted documents will help determine if the project is in compliance with building safety codes, , zoning ordinances and r other applicable laws. The Colorado Chapter of the International Code Council is a professional organization seeking to promote the public health, safety and welfare to building construction. We appreciate your feedback and suggestions. To obtain a master copy of this building guide, please write to the Colorado Chapter of the International Code Council, P.O. Box 961, Arvada, CO 80001. This handout was developed by the�Colorado Chapter of the Internatrona'I Code Couricilas a basic plan submitta(,under i a ati 2000 Internonal, Residential Code. It is not mteriddd to cover aif circumstances Check with your Department of Building Pafety foh additfonal' requrerment'; ."' aty o Wfiieat Wj'dge AT Bui tng Division ° Ra 7500 41N 29" Ave. m Wrzeat Ridge, CO 80033 (303 235-2855 c ocoRao o 1 1 Directions . Fill in the blanks on pages 2 and 3 with dimensions 3 3 G `3 A, 5T and materials which will be used to build the structure. Please print legibly. 2. Indicate in the check boxes on page 3 which detail from page 4 will be used. Note: Heated garages may require special provisions. Dimension /y " Locate and detail bracing IWAH I L • Garag=heated ❑ Garag Indicate rafter or truss direction Show door and window header sizes and location and size of landing in front of door 3 minimum concrete slab 2 x b o header (example: (2) 2 x 10 Note: If roof trusses or rafters bear on header, special header design maybe required Floor slope Double 2x4 or 2x6 trimmers each end of overhead door header — Garage door openinq door opening width ., p ngension Dimension* 3 * 2'8" minimum, with plywood sheathing on outside of entire wall Dimension* 3 with hold downs. If less than 2'8", engineering may be required. III This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2000 International Residential Code. It is not intended to cover all circumstances. Check with your Department of Building Safety for additional requirements. Subject to Field Wheat Ridge Building Dept. 2 Checker Note: For roofs with slopes between 2:12 -4:12, follow manufacturer's instrustions for low slope application of roofing material. Sheathin —� 7��'d53 ❑ Truss or 2x t4rafters spaced O.C. g (example:Putcheckma inbox -or -2x10 Rafters Spaced 24'O.C.) (ex iple: gz"extenorplywood) Minimum 1x C& ridge board Roof covering S t4 .t (example: 1 x 12) (example: Class A 3 tab s mgles) Provide roof tie downs and solid 2x blocking between rafters (2x12 or greater) Note: Pre - engineered roof trusses w /truss clips and hardened nails may be used in lieu of roof structure shown. Diagonal wind bracing or plywood shear panels @ corners and each 25' of wall. i (see page 4) This handoutlwas c International ICode the 2000 IntQrnatii to cover all aircum Building Safgty for Code. It is not intended vithwour,Deba €tmeitt of rh / p tch 5 E ling Insulation P (if heated - example: R -38) 2x__6__ceiling joists @ �( O.C. (example: 2 x 8 ® 24'0c) Double 2x top plate (example. 2 x 6) Span (example: 23' 5 J Ceiling heigh Subject to field Inspections Wheat Ridge Building Dept. 3 s a r, I T... _. Sign e Plan Checker k: _ qW l (example: lap or F111). j Wall sheathing�� (example: ' /z' extenorplywcod) 2— 11 tuds @ t b (example: 2 x 6 @24'0C) -.;;. B (example: > r: 4i Cont. Zxsill plate 2 x 6) Wall Insulation AJ A (11 heated - example: R -19 Fiberglass Batts) Footing size _x_ (example: 6' x 16') Subject to field Inspections Wheat Ridge Building Dept. 3 s a r, I T... _. Sign e Plan Checker k: _ qW 1 /2" x 10" steel anchor bolts 6'-0" O.C. max., 7" min. penetration max. 12" from corner Lap siding over foundation a and 12 from each end of plate. minimum of 1'. Bottom plate shall be min. 8" above grade, or be \V- I treated wood or decay resistive wood 3 1/2" Minimum Concrete Slab mm Finished grade min. Jr. #4 rebar min. cont. top & bottom Note: Check with local department for swelling soils. Caissons may be required. T Lap siding over foundation a minimum of 1" Note: C ck with local building depa ?ent ,A ent for swelling soils. CaKsons may be required. 1 /2" x 10" steel anchor bolts 6-0" O.C. max., 7" min. penetration max. 12" from corner and 12" from each end of plate Bottom plate shall be min. 8" albox or be treated wood or decayresl wood 3 1 /2" Minimum concrete slab Fiberboard expansion joint Provide ar ve 11� 4�4 O . C . insert rebar Into conc footing or key way 3 11 This handolt was developed by th6 U&AaOcWQPO��tlha Subject to Field inspections Internatio, C o d e Council as a basic plan submittal under the 2000 lnternationaPRbsidentia6Code.it is to cover all pircurnstances. Check with yo of Wheat Ridge Building Dept Building Safety for additional reqVjrements. I ;Z4 Sign ..... �Plen C�hec .19 lv� . .; c® »�� : »• . / \� \/� .\ � y � \ ƒ< / 9 ® U3 *� 7 £ D \/ 2 ` \� <mm/ \ » % 2,- _ ..- % m £ . <;afEm . . » { / / to - . .; c® »�� : »• . / \� \/� .\ �ƒ � » / 9 ® U3 *� 7 £ D \/ 2 ` \� <mm/ \ » % 2,- _ ..- % m £ .S _ - i »�� : »• . / \� .\ �ƒ � » / 9 ® U3 *� 7 £ a� 2 ` \� <mm/ \ ^ \\ _ ..- \ / \� .\ �ƒ � » / 9 ® U3 *� 7 £ a� 2 ` \� <mm/ \ ^ \\ _ ..- y � .� - 41 \�� § y )m $§( >j /\ . ®[ � \kk� R ®§ D \ \/\ \�E ;E\ \ \� i f = \ � $ � p t . .& . � .. .�> 4ZA < 0 G w w op c! J ? z �v 1 I . f �I i � � ; � '' `�'� �� �l � �`" �� •7 a ✓owl's ^' °� COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: _ -11/;', J/;y . Q;i>..-=-FA A/.,)JLNIf"lA.I~ #t!VY':Ai . / ? ,5/11/;('" /')eA/,./ ~ /V~ gp- /N~//?;;J /11/70 ... 5'" Lt~~. /7 ~d'.~A/& ~>r~ &//87) -i" /ZQ 0i0 CJ;e A?/R 7/ <<:-7'" ~/7JV/R/O? OAJ ~ ' '- )x'5~ if. d % L::;::V7#~.c# When corrections have been made, call for re-inspection at 303-234-5933. ~-~-~ ~~~ {II' nspector DO NOT REMOVE THIS NOTICE Date: ~I ~/()(9 To bLM IcL] ')Lft, ..:r O--~ (~b ues-hf') ~ 6 r--, ye:-f rN 1- n lJ-.~ b-eI s )(.0 1 -01 a..-,J I 73 2, I CVT ~tleef c...oA6.,ess ~ ::,?:;,(O~ J~ ST. C0h..z.u.;t R~0e / Co . ~o33 Th \ 5 ?' 0 Cj-.e.ct- hCA-~ beer-, 0 Y\ h b 10\ r ..t -f'-Ndve. TDv +he. -pe-.<:, a' ~ft'm6I1.ths or So d. u.E: .t= f1 ()c..h ~ d ('est-, OJ f'.Ts G..S ~e.t\ ~-nme (e.s+r~nts, ~0e.. o..re.- now S-\-OJ~"J ba..cL u-p OY\ t-n~ ?crp --\-D~ ~~cA-) ~ u-Y. +1-JR. ?(~,.\.ect. ""~ 'b~r Ov---l SC.c.-tio..... hGS been s. 3~czcl-l of+-. \h ~'" L Y D 4. toy- CD y--, 3 \ d eJ ~ ':J 6 u.-v ('~b L-\.<Z..~t ~y c...-.. G~1-~\ OY) G"', -th~ ~ ?~ i'0-'1 ts . . \ Sffi~t~~:JJ) Oy-. ~i "'~( ~\ /' \; J 'Sl,UL .J\ UGV'\ 0'1 \ 0IoY-c. I ptJ ~Cr\ ~ V .~l> ~" ~b\? (3()~ )Lf S 1) ~ 'GOt S \ ti~~ <If \P ----r--.---.~-- I 11/09/2006 13:44 303-556-5381 MTH & CS PAGE 02/02 ~ STRUCTURAL DESIGN COLLABORATIVE LLC November 9, 2006 JEFPERSON COUNTY BUILDING DEPARTMENT Re: 3363 Jay Street Addition Wheat Ridge, CO To Whom It May Concern: Structural Design Collaborative, LLC, represents and acknowledges to the Jefferson County Building Department that structure for the project referenced above has, to the best of our knowledgc, belief and opinion, been completed and integrated Into the project in accordance with the construction contract drawings prepared by StructuTllI Design Collaborative, LLC. If you have any questions or comments, plcase do not hesi.tate to call, Sincerely, STRUCTURAL DESIGN COLLABORATIVE LLC STRUCTURAL DESIGN COLLABORATIVll, u.c .3350 OSCEOLA- ST. SUITE 200 DENVER, CO 80212 (303) 480-9501 FAX: (303) 480-9174 E-MAIL: STRUCTlJRALD@EAATIlUNK.NllT COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: _ 3:3'/n. q , / /l Y '- <;7/?A~ p~/r'fi? /~nkL/- /. > A1J(~ <;. 4.? (Ji/~k> fiCZV H/,E' R~~//~ ~-~~ .27 Ir., ,/? Pi//) A::: h1X'e(~) /eNL./.L?Y"';- <;. D ' ~ / // /,.- '7/"" v. ?' (~AI.I Y ..:2 - /?-.? ,.o~1"< 'l'/- //L: '- <ITA ,vj.r p . 4: ? /VAl' VJ//<'/~ ,""#A-'~ A/r:r/ g~ .57fi/0::7/..<:7J OI'V c.o6".... ~U:~~ '~::~~. W/97/~/9 t. 7' &,p( //1/ &2'k'Od.P"1' /h.uN'C: #u<;7 /~:o;~~~;:::~;::?V' //;55 ~/ /~u /?f'..-n LZ/c1:z C7~ ;.e: /tI, / ,... ~.R/,t:O. en corrections have been made, call for re-inspection at 303-234-5933. Date: 9- .,. /:2- L /-11-1 NOr?:/1 ,4C;:,C ~ .' to ~,pector rz IZ -:5f~~ U"v/7 c9 5//f ~ o DO NO I REMOVE THIS NOTICE \R\EC\ETh~ED OCl 2 72.005 /O!CJ.3/05 --- ----- ----- f€f(y\, t # /6;731 ~ ()0I. Ocp -tvp *:# I 73 OL J c ~ ;)0; ,J,^~ r I del; her, IS ftrnp Of OJ,:; 0" hoJ d a....+ +'hl s -h'Y'w? .p(e0-~ ~p Me.. per rY'1l f- op en Gf/ i-f, IS P f ocJ..ec t. KeSI d~hd QclJ.rL'sS '5"5(03 ~~ s+' '-0~,,,-.A- f2-:- d J~ .;:;~ -} VUY) G I 111"0 ( e 303 L/ S 8 - ~\ 75 /~~l. \O~ //////v}t/ bA71\/\ \ / / IF'" (1~~V0 / ~~V~~ ~~// / I~------ COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 17321 Date: 7/2/2004 Property Owner: DON GILMORE Property Address: 3363 JAY ST Contractor License No. : Company: Phone: 458-8075 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Total: $3,000.00 $108.30 $70AO $60.00 $238.70 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable W eat Ridg~, ordin,nces, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ' r" DATE 1j.J- J DLf . . Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description: FRONT PORCH W/ ROOF. 6' X 20' BUILDING DEPARTMENT USE ONLY g'ql1!~i6t$: Approval: TRC Zoning: R-2 B~IT_~om,~ Approval: CR elftn~Wvork&iiifttn~s: Approval: Occupancy: R-3 OK SIC: Sq. Ft : ~%er I Collllact Pleas a es 8IJd cOIlS Oris res e !Vote. Tl'Proved pl tructillg i,;{'OIlSible f~ I e City is Il 8IJ and req..' provernentr OcatillDp_ sub, ot re ~lred d's ac "'''l'eH.. 7/1/04 1l11tted with' sPOllsib/e fi eVeloprn COrdillg to th")' error II] t.h Or 'n em Stan e s reSUlting fr~PJ8IJ Set :.n~ccurate illfo dards. rn JnacClJt4.,f~,a~y COl1sttul7r,Ctl~tjon ., 1/)fo"" . lOll allon. OK W/ NOTES. Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge. Colorado or any other applicable ordinances of the City. (2) This pennit shall expire jf (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this pennit expires, a new permit may be acquired for a fee of one.half the amount normally required. provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. Chief~;? Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) APPLICATION 1:>0 ~ 6', \ OX> < e. 00<.0 a S=-, :5.... Property Owner: Property Address: Contractor License No.: Company: Building Permit Number: -r "" e Phone: X:J ~ Li S i? - ISO 75 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone: n ~ ' (~\1f"i I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. IOWNER)ICONTRACTORI'SIGNED(?~""- J~'~ DATE~ (OWNER}(CONTRACTOR):PRINTED -O('}~ bi \rno<e., Description:.- ,,'- , rY'Dn\- .0(<:"" Wi->-" IZ06+ 0' >< ;,;u) Sq. Ft, added I'Z.O' Construction Value: ~)cC Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ BUILDING DEPARTMENT USE ONLY ;::ONING COMMENTS'~ Approval Zoning: f''Z BUiLDING COMMENTS: 0-1(. t.>iJ.-l.. ,.."fj!':> Approval: 7~' -0 c.f c, 4:.~ PUBLIC WORKS COMMENTS: Approval: ocCupancy:e~ .3 Roof: Stories: Residential Units: Walls: Electrical License No: Company: Plumbing license No: Company: Expiration Date: Approval: Expiration Date: Approval: SIC: Sq.Ft: 0<:.\ \~\EC\E.rJ\E.\O \\\~ 7 lj 1(\(J~ . ~_----:.:J \.;:------ Mechanical License No: Company: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally re,Quired. provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem, (5) Contractor shall noUfy the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the prov' 'ons of the building codes or any other ordinance, law, rule or regulation. J / ~/ 1\1) Q- ~ 9 ~ ~ 1 ) / / X ~ , ... .... ;,,,,,.. ''''y ~ It ... t-.". () .... ~ ~ ... ~ ~ I", " -.l t-: , '" <::: '^ ~ ~ - .,. () '::t. -~ - ~;1N:> ~ ~ WhHt Ridge Building Department ~ if-) ~.. ~~7-/~~ 8 ~ m ~ ~ oJ pennt n...... oJ ellllll1lor 11J1lIIlI11II1II-, ~. '- <-l) lIld CXllI1plU1IIcns ~ nal.. e pennlt far, or ..l1ppftlWIIIII. .., WaIIlion III '9 ..;:, .., 111.. JIlllNioo16I11" buIcIng CDdI or oJ .., CIIy~. ~ ~ "-mlII......'ll1O give 8IlIIllriJ 10 WallIe or l3IlCII.. JIlllNioo.III" -:: ('0 buIcIng cxxIeI or oIher IlIlIiMlceI oJ .. CIIy ~ nal.. WIld. - D \ ~ ~ ~ ~ (\... ~ ~ ~ ... " ~- ~ ~ <. Gl .., ... .., o 0 eGiS ::.0 o.l:3" ccn- (~ "'.- ",co ::I .., .gt cnMii oG~.. eM. o ! Q 3 1 ~ '. "- "'" r :p. I , , i ~ 1 ~ ; L_ . ! . "- , ~ '\. ~ :>: ~ I G 1" ~ ,., ~l\ CL '-Ii ,.. <it f'0, ::;< ,~- 4: ~~ jTU . I- . .- - - - - - - C I- i- .- f~" . .... - ,~ (' -.~ ~ ,-:-~ <> - ~ I. ';:,. ;j 1?, '!(! :r ... " -:too '" , ~ '" Gl '" .. 0 0_0 EGlco =GlO C)~" e(/)'" ., :>. - ",,,Gl :S.., 0> 'tI (/)",- oil ",a: "'- e C') IV o Gl Q .c ~ .) ", .\ ~ '" ", \. "" \,,';' - ~Y" ~ -1t Q.i- c!lf t"] \\r- .o..Q 11 L ~ ,!I ~- ~ It ',. -:u " ~ ~r\] - ::> >( '\l -- - '-l _U~ e 1~ \,{) ~~ ~ ,... ...' ~ "oT \D ~<S> l[ , ~ ~ ~ -.. . (' <"", ,,5) ~ -+.? ~ ~ ~ 't ~, . -, \) ".a ~. ~ ...:! < -;;t? & ~9r.t' ...~ 0 'It !li!F- ~lJfl{, ;J , tfl. (~' T , ..a 1 Don", " 3363 ,L Wheat Ridge, co 80UJJ , .. '-I x'/ (JJs1? ,- ~'Qt/~ NOlSNIM ON" IHVH1NIH 'llOH JO SlN1WlldWOJ 1 -I -III II III III II I r I III III III I 11-111- I_II III 1'1 ill 1/=-111 III III ... ~ POST 'SIHPSON' BASE CON/'IECTOR j . '-Il \ 8' Sa. OR ROUND LU/ (4) No.4 REBAR ~ No3 TIES CLEARANCE 1/2' HIN. - 3' HAX. - , N(,I, ~N ~ ~ . -l "'\.) . ~ -t J. I 3 pes. NO. 4 REBAR Ea. WAy 7' IilIS APP/iCqllor-.j OJ<, j,~,rl-l 13z Go- r-co',S .2'1 " ALL FOOTINGS SI-IALL BEAR ON Squd'-" or Rcu>d UNDISTURBED NA TIVE SOIL . ALL REBAR HIN. LAP'; 24' TYPICAL EXTERIOR COLUMN FOOTING 7D T/I t:. Lo-'JO ( ~1fI) of- ~//J~) I':b c- ;r.; ~xc EE,& t't7lJO I b.s t..J I tf. / (;O:;J FS.{l Y7'1/ AJ Sa / c.. ehl~J /l.J6" C'!.iO *' ~ . NOTE, _ TI-lE&E ARE MINIMUM STANDARDS FOR INSTALLING FOlJNDATI~5 FOR RESIDENTIAL PROJECTS. COHHERCIAL AND 'SPECIAL' RESIDENTIAL PRoJECTS WILL REQUIRE ENGINEERED FOUNDATICNS. STANDARD NO. MINIMUM fOUND~TION Sl~NDARD) F-'f "'~'4 " . Single Family Residential Uncovered Decks and Porches DIrectIons 1. Fill in the blanks on pages 2 and 3 with dimensions ~~ ~~~ ~ and materials which will be used to build the .J. . I structure. Please print legibly. /'Aiil, ~ 2. Indicate in the check box which detail from page 3 will be used. 36 inch high guard with ba1usIers spaced so that a 4 Inch diameter sphere cannot pass through Attach decking with non COrrosMl fasteners Conditions such as attachment to cantilevers or veneers may require Enginee(s approval Q) <5 c: '" '" S c: 'e .5 co it co Finished de No": If an exit or egress from the existing building passes under the proposed deck, or n there is an existing patio under the proposed deck, a miniroom clear headroom of not less than 6ft. Bin. must be maintained under the beam. Please indicate opellillgs in existing wall. ('7) - 2x_ b joists spaced Ii," _" apart (eUJJf.1ll: 2 x ur spaced 2'" apatt) <2J ,). x_B-beam (~:(2)2lf 10-..detaiB) 2x~ rim joist (axany.JI8: 2 Jl10-MeAJfemafeB1 & 82) ~ ,1 -!:I-X-L posts spaced (.,1 apart (_,'.4__"""") Span (..L~3"") Note: A plot plan (plan view) showing the dimensions of your project or addilions and its relaIionahipa to existing buildings or stnJctures on the property must be included. In addition to project d~, your plot plan must also show olher details such as post locations and spacing, joist and beam spans, and any other pertinellt Intormetion not shown on the section drawing. ThIs handout was d...aIoped by 1he Colorado Chapter of 1he International Code Council as s baSic plan submittal under 1he 2000 International Residential Code. " is noI,inlended 10 cow, sll circumstances. Chock wIIh your Depsrtment 01 Building Safely lor additional 'equirements. ,.,. " .>" y,> 2 712102 RAH , Single Family Residential Uncovered Decks and Porches Detail B Existing building j;ApprOVed flashing required ~ Attach to joists with non-corrosive fasteners I Mach ledger to existing bldg. with non-corrosive lag bolts spaced min. 16' apart Locate bolts to penetrate rim joist or wall studs. Secure balusters to beam Non-corrosive metal joist hanger Non-corrosive metal posl/beam connector ,\lternate Detail BZ Full depth 2x solid blocking Secure balusters to beam Secure balusters to beam Non-corrosive metal postlbeam connector Non-corrosive metal postlbeam connector 'k' (min.) diameter anchor bolt embedded 7' min. into concrete pier or the equivalent 8' (min.) diameter pier Non-corrosive metal post anchor w......' 1-;''".;;.... .,.~.;::;~;:~: to 'E .. .. .c .~ '" C") This handout was deYeIoped by 1he Colorado Chapter of 1he Intemational Code Council 8S a basic plan submittal under the 2000 International Residential Code. It is not intended to cover all circumstances. Check wrth your Department of Building Safety for additional requirements. 3 7121<12 RAH Single Family Residential Uncovered Decks and Porches New or existing A light required Y Open guardrails and open handrails on decks and stairways more than 30 inches above grade or a floor below shall have members spaced so that a 4 inch diameter sphere cannot pass through. Stairway Noles: 1. Stairways shall be not less than 36" in width. 2. Stairway rises shall be not greater than 7 314".- 3. Stairway treads shall have a minimum run of 1 rr. 4. The length of Run and the height of Riser shall not vary more than 318" in the entire run of the stair. 5. Stairs are required to be illuminated. 6. Open risers permitted if opening is less than 4". 7. Mmimum 314" nosing Handrail (see details below) Guardrail ) 36- min. height Deck Not less than width of stairway Guardrail required if more than 30" 1 rr min. run Open risers less than 4" 4 inch min. - 7 314" max. rise ~ Landing Finished grade Handrail Noles: 1. Handrails shall be continuous on at least one side of stairs with 2 Of more risers. 2. Handrails shall be placed not less than 34 inches nor more than 38 inches above stair nosings. 3. The handgrip portion of handrails shall be not less than 1-1/4 inches nor more than 21/4 inches in circular cross section. 4. Handrails shall be placed not less than 1-1/2 inches from any wall Of other surface. Per 20111 Supplement ~11/.' -2'/" max. 1'/2" min. 1 '/.. - 2" Gripable Wall Of other surface This handout was d.....loped by 1hs Colorado Chapter oIlhe Internalionsl Code Council ss . basic plan submittal under Ihe 2000 International Residential Code. II is not intended to cover all circumstances. Check wrlh your Department of Building Safety for additional requirements. . 4 7f2102RAH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 16962 Date: 4/16/2004 Property Owner: DON GILMORE Property Address: 3363 JAY ST Contractor License No. : 21925 Company: A2Z Electrical Services Phone: 458-8075 Phone: (720) 363-7238 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Total: $2,400.00 $108.30 $0.00 $28.80 $137.10 I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR)SIGNED h 17' ftyv::"" DATE L//I&!r)~ . ~ Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: Description: MOVING ELECTRICAL SERVICE TO THE BACK OF HOUSE. CONVERTING EXISTING ELECTRICAL PANEL TO A SUBPANEL MAIN SERVICE WILL BE RATED AT 200 AMPS, WITH WIRING OF 500 SQ. FT. ADDITION ,....... - BUILDING DEPARTMENT USE ONLY [ftJ !1D1L{n ..~~ SIC: Approval: Zoning: .~ Approval: .....-r~~i I... ..' Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : 21925 Company :A2Z Eiectrical Services Expiration Date: 2/28/2005 Approval: PUS Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. 'i4t. I U/Lul ~ I (Y(Ad fl5?J f @ Chief ~uilding Inspec 0'tge Please sign Terms and Conditions on reverse side of page, ~' .H(~r ." , / ~ '" - C> u ~ COt. OR....Qg COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) APPLICATION Building Pennit Number: Date: bOrJ G-'!",cRc s% 3 S?'( sr: 7/q2$ /I 2-'2 ht.er:!-,','("L C') /155-8D7C Phone:::' -, J Property O,,"er: Property Address: Contractor License No.; Company: Serv,'us Phone(7) 30S - 7 Z 38 OW!'<iERlCONTRACTOR SIGNATURE OF ll~DERST A......D1~G AI\"D AGREEMENT Construction Value:$ ji{OO,d> Permit Fee:$ ; Plan Review Fee:$ Use Tax:$ Total:$ I hereby certify that the setback distances proposed by this permit applicatiOfl are accurate, and dona! violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made arc accurate; thai I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheal Ridge Building Cooe (U.8.C) and all other applicable Wheat Ridge Ordinances, for work under this permit (OVl'NERXCONTRACfOR):SJGNEDfl /~ 4'j."--,~L- DATE (OWNERXCO~TRACroRJ PRmrED PI, ;111 g }:~;;;'),Jll'1 DATE r DESCRIPTIO/'\;- MD()/:-"50 eledr,col. 50'0//(< 1z/ -he Cuch.'UoL. f-"AJeL fb "-'-' U-Sl./h""'lVe(~, ;11.4,'".) "S,,'(u,'ClO Cl. (cx:J/J,n..1" .br:~.ahr fa, $L, b/,'o/VP [. ., , - k!,'tZj~'() of 6:::0 s~' t=t.. dc:1,f I,)/J. 41/do Y If!;/; !()'! t~t 'AOlt! c?{' !IouSf'. {~J'/ lIU-l,'o'\\ ek ,$fl~:-r- be tzpf.,o/ "",( ZLJo (hmPI tJYR BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMIENTS: Approval: Zoning: BUILDING COMMENTS: Approval: Puauc WORKS COMMeHTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: . Electrical License No: Z / q 2S Plumbing License No: Company: Ih? &.a/-r,G ,t 'S<'u,?tJ Company: Expiration Date: zIzs/o'5 Approval: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval; (I) This permit I/o.as wo,aed in accordance wilb the p.-ovWoos set (orth in )'OUr app6eatioa and is subjct't 10 the laws o( the Su.te OfCOk;.rNo and 10 the Zoning Regulations and BuildinJ Codes of What Ridae. Cokndo or.any ocher -WItt-able ordinances of the City. (2) This pmnit shall upi~ if(A) the wort IUtboriud is DOl commence<! within sixry (60) dlys from issue date or (B) the buildinB aulborized is suspended or lbandoned for a period of t20 days. (3) Ifll1is pennit e,"pir~. a new penllil may be acquired for a fee ofone-half~ amoum llOfffiall)' required. JHo\'ided noclanses hive been or .....ill be made in Ute ori~nal plans and specifications and any suspension ~ abaDdonmeal has not exceeded OCM: (I) year. If cwses have been or if suspensKNa OJ abandorUMnl e"c~ OM (I) year, ti.an fees $haU be patd (or I new permit. (4) ",,"0 work of an)' manner shall be done that ",'in chan. ~ natural flow O(",..kf causm.1 dr1inaJC probkm. (5) CootraC'kIl'sh..n notify the BuildinJlnspct10f rwary-fOW' (24) hours in ach..ncc for III inspections and shill re<<i\'e Wr1um -wroval on inspection card befOft' proceedinB wirh successive phases of the job. (6) The issuance of I pmnil or the 8pp1OVl.l of drlwmg5 and sp<<irtcations shall DOl be coostrued 10 be I pennit for, nor an approval of, any riobtion of the provlSIons of the buiSdinl codes Of"'y omer ordinance., taw. ruk or repllcioll. t'h ,'~{ t,' i)f,;'i_ 'rei Chief Building Inspector COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE. (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 16739 Date: 2/26/2004 Property Owner: DON GILMORE Property Address: 3363 JAY ST Contractor License No. : Company: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone: 458-8075 Phone: Total: $40,000.00 $705.65 $458.67 $800.00 $1,964.32 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable W eat Ridge ordinances. for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE /J./;;J3.!o'-j I f Construction Value: Permit Fee: Plan Review Fee: Use Tax: Use: m~ Description: POP-TOP & BUMP OUT SINGLE FAMILY RESIDENCE. BUILDING DEPARTMENT USE ONLY Z-. .1"-''''.. ~{,~,n..;{; Approval: MR Zoning: R-2 l:UIIIil:l~_ Approval: DM _i~liiqaEr!tII Approval: SIC: Sq. Ft: 12/20/04 Own Please Note: er I COft!racto ' lines and r.1S ";sponsible rc" locating prope"" constructmg Improvcm ~'--.f '. c/o . 'i approved I ' :.~ ., c,,,S iJc.cc,>t\.;ng to th~ The C't . P an and reqU;H..d development :>Iandards I Y IS not responsible fa ; .'. submitted within the I, , r :naccurate mformation . p an set and any construction errors resultmg from inaccurate informatl' on. 2/12/04 Occupancy: Walis: Roof: Stories: Residential Units: Eiectrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Gode of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. The issu o~. rmit the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provi' of h // ( ;d8S or any other ordinance, law, rule or regulation. (4) (5) (6) ector Please sign Terms and Conditions on reverse side of page. COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) APPLlCA nON Building Pennit Number: Date: ])on Oi JrYlDVe.., 33&3 00-y 51'" Phone: 303 L/ 5<r' ~O 75 Property Owner: Property Address: Contractor License No.: Company: Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING A"'D AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, ~ and do not vIolate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C) and all other applicable Wheal Ridge Ordinances, for work under this permit. COV"NERXCONTRACTORl SIGNED ~ (O\VNERXCONTRACTOR): PRINTED /}.,( Construction Value:$ 1'90C/o Permit Fee:$ 7,}7;";:; Plan Review Fee:$ tf5!f, &.' 7 Use Tax:$;:reo. "'^-, Total:$ /9fr/,52 ftDESCRII'TION: pO;:J 10.? a~ b(./~~ Ov+ Dr', r.'\ I.., ,iy -7ji~O' ' ,lif (~:~ 11d) J BUILDING COMMENTS:(5;Jf.::- Approval: BUILDING DEPARTMENT USE ONLY J., ~/~,.-I 'O/v II" I '\J \1\) {y J.jl 2) otI SIC: ; Sq.lft: i I , ----- ZONING COMMENTS: Approval: Zoning: PUBLIC WORKS COMMENTS: Approval: Please Note: Owner I contractor is responsible for locating property l!ncs :md CC:i~tructing impro.;emcn~ ::ccording to the rp,roved pbn nn::! r~qurrcd d~Yc!oprn.ent st::mdards. l1~e C~~J' is n~t responsible for inaccurate information submi:tod within the phm set and any ccru;!~ocllo;} errors resultinr:; t'om in~ci.ll':ltc :~L:::r.~~:on. Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (I) This pemlit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) lllis pennit shall expire if(A) the work autllOrized is nOI commenced within SiXlY (60) days from issue dale or lS) the building authorized is suspended or abandoned for a period of 120 days. (3) !fthis pennit expires, a llew pemlit may be acquired for a fee of one-half the amount nonna]]y required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (I) year, full fees shall be paid for a new pennit. (4) No work of any manner shall be done thai will change the naturalllow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receh.e wriuen approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a pennit or tlie approval of drawings and specifications shall not be construed to be a pemlit for, nor an approval of, any violation of the provisions oflbe bui . g codes or any other ordinance, law, rule or regulation. City of Wheat Ridge Community Development Department Memorandum TO: FROM: SUBJECT: DATE: Don Gilmore Meredith Reckert ~uilding permit - 3363 Jay Street February 10,2004 Please be advised that the owner/contractor is responsible for verifying locations of property lines prior to construction. No surveyor improvement location certificate was submitted with the permit application. A "to scale" site plan was submitted however, the lot dimensions are somewhat different than what are shown on the Jefferson County Assessor's Maps. See attached redlined site plan. It also appears from the assessor's information that there is a detached carport and covered porch not reflected on the site plan. Please include all structures on the property so we can compute proposed lot coverage. The owner/contractor is responsible for locating property lines and constructing improvements according to the development standards for the specific zone district (R-2, Residential-Two). The City of Wheat Ridge is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. Property appraisal system http://ww4jeffco.us/ats/displayinventory.do ?improvement= I &sch~... Assessor's Office Property R!l<;<Jros ~ (;e..eral (u for_adou ~ Tax & "aim' ltirorluntiou ~ ~ighhQ.dlO...d S.ttles Ad, alilcc S"les Sea I OF 355 Next Schedule: Parcel:39-252-13-007 026167 Property Address: 03363 JAY ST Property Type RESID Year Built: 1942 Adjusted Year Built: 1953 Design: Ranch Improvement Number: 1'J:llliJ Quality No. Fair I Fair I Fair I 2 2 I Item 3FIX-3/4 BATH MAIN FlREPLCE FULL BATH BSMT BEDROOM MAIN BEDROOM BSMT FIREPLCE Areas Quality Construction Sqft FIRST FLOOR Fair F 1258 BSMT FINISHED Fair 958 COVERED PORCH Fair 297 DETACH GARAGE Fair C 200 BSMT TOTAL Fair 958 RES BLDG/SHED F 80 Send mail to asscsson'C/)co.icfferson.co.us with questions or comments about this Website. Copyright @ 2003, Jefferson County, Colorado. All rights reserved. A Map of How to Get to Our Office Website information current through: I of I 2/10120049:33 AM {' ~ r ;~. I ."---~- r- I I I . I i'i-'. cT r" ..-......D \....... i ':-J'; ", ~ {'n J ! I I \ ;; i' ? (j I u r:: (,7 " ~-::",' ~-= 'i .-, '-) \(~\ J N '1"., '- l ""I, or', r-','~ r~~-::-::.,._~_' t \ .~ -' . I ~ I ,. il II Ii ; , 'td;n\ I J .: i a I I~.. 1-- l~ ! 1.'1"" \ i , i ii -~ -c "\ '..;~ '-:- "l- .-1 '. '. .;--'/ / "",.~-f C' -:- L.' ,) ,- r"l"~ (' ....._'" n....../ -_~-- I cJ >-- 't~~l_~- ~ \ \- fo \If\ '. 'I - - - '-1~ I- I f ! r~; V//1 " \-,.'. r~ I ..J~ r- I I I - ~ l/evJto!n<,,- (/ o ,.', ~ 7': -.---.-----.. .. 0 L'l '.;;,. f- "- ',J \J; .Ii 0' IfI \,. j\1 r' -' ~~i _1 '.. ,:", , , <: !,! .. .. t . -}~f" I.'f'" Ll~ !:1' 1'1 2."7 ;- i I I"c. 11: r l. oJl,1 01 ~JI 1 L_ t F';',;., "." c: ~:; ", . :" '~' -l'" .~ ! '2 -;; ,I' f-' tJi r1;1-' 1-= 1 '~" I r~: I , 0', pi ~G (-_~ "3 I ~. .:\C" I.i -~ , , ____1_',:_._?~9 -'-' , L. \ .c.. ~. I ! il ,. .5CRLE , !i .0 -ao 'J'i,Cl~'. '''''''~'':~l;....;j 'j.: Thlt ,.,lIfl:n thot the aboy" It on o((urc1e plot ,-f CI IlJ,,,ey mode this. 2.cntL- cloy of,_.AJ.lmJ~.t-.197 '3. ;!! ofth.pr~p...,tyd",c.!b"do' Tract 1, [-'::n';-;T AODl'frC'1 TO HA U":V SUBDIVISION, County or ;:1 Jerferson, Statog of C'.:'llc::'"-?d'J.. ~:: 11 Ii ,..,j :':: '1'.''1'1' ''>L ' IncludIng the I"cotlon of Improvement', lnown ~ose<'! ",.,is-, rlghts-or-woy and ancroodH"e"h by or on the pre~IJ.'. l~h IvrVfJY should nc! bl!t vs~d for CO;1s:rlJ~f;:'Jn (If f!)f\lt'1 or l.":'" r lmprovem!""'.s, CARLSON [N,~ 1 '" JF: EH:r ~~l. INC. " 35 West 5th A..."rluC' De-nver, Colorado 80;04 ":none 722.9741 222-9742 ,. ....'.. .,- -n....-l I I I I I II !, "-... --~ '. ! '( f.. ~. ~ ~ 'rl !' p" c> fJ .\ -- : ~'J . .' 'c"A P."J::; '\' SuSD I:,' ).-! AR_511N NGlt~EER 1i"[J N :::;. .:"'_ i--~.'- PoGO"'; cou~,JT" .../ .c_'. " ~.,~ ~~-1.~ / / .....,~.... --', ',' ,) .-.1'-.... .-'-~ 0' ~0- ~.-:c;.-: \\ _-1-;~ ~ , I ,I,. 'i S r~"'- 1'- r- , I ._- ~ Ne....'.,\.tnee.. ~ \'C:,:: .-,:, <.i"~, I \\ 1\ Ij ~I II r- \1 ' ~I I i~'. -:-:.? I .._t '1'., I' i I,.. .,- il, J ,. "' '" rl, ; .; ~ ~ P',' ~"?i' \" ,<'.<\ ~,1 .c' (,.,.-Z-' ,'I, L ~ Uti 'I:: --, ., [' ". , e, Pi -----~-- Tf,.' ;~~'-. 1 I l \ "--.?:iJ , 5CRLE ' ':1 "2.0 "tRAC1::c r.;.:-:'i'~ Thl.~.rl(ll,. t"ollh. oboy. II1In lI!cure!. plol 01 0 5>""'Y ....od. ,.... --20l.h....- day 1I1_~lU_lC7'. . o"h.p'op..tyd~.crl;'fodol ! Tr.?(:t 1, FIRST ;"ODITION TO l1A1.V":Y SUFDIVrS10N, Count1.,r Jefferson, Stat~ ~r C~lo~~do. '1 I ~ I' " ~"'l I 1 I' J ~.. i IndudlnG Ih. 1,,,nIlO" of Iml"lI".ml"h, ~no",n .o,""",,,tl. r111hl..ol__oy co"d ,n.rlloChmI1'l1l by O' on Ill. pr..ml'lI. Ihll ,,,,u'y .hllvld nol b. ",ed .lor co""'u,lbn 01111'1(.1 or (l':.er lmp'oy.m~n". ..... :~- CARLSON fNG1NEEflING, INC. 35 We~1 5th Avenu~ Denv.r, Co:llm~do 80104 tnnne n;!.!l1,11 rl?9742 ,. '!>'" SEAL C.....NER !>l-\l.',on.- Port ,!!:,yr," "':,r-"::l,~e Co. .\ ~.,,; ,-t_ '. ..~Li-LSS, }J53 Joy Street llTLECC: Zd.. '-...."'- -'. ~-~':&::-/. <;11l::>V~"'r-.JO'. !~22~___.__ C/,SEI-iO. ~ o ci o .0 \- '" ~ " r " 'r < " \ \ z --- "- \r, <. ~ ::- J / ~/ 'v> ~ y; ~ ~ ~ 1 ) / I <- f'() ~""Q ~ -::. .... ~ ~~ r.z " ... , "' I-... () - ~ "" "' '", C$( t-: ... <:: 'v, //~ ~ "' '\I ~ I ~ ~ ~ V) ~ ~ "t =t I...:J / - t>- ~ \ <.. +- '??/{.C? /iYf :> z --- -<.. " \n ~ ? J :> / Iv:> ,vi 'v.; ~ ~ ~/ 1 ~ ~ / / I 0 I'() ,~ -~ = '>..~Q ~ "" 0 - ~Ql- ~ ~ , , f:( .... -<: ~ j, , I---.. , IV') () <:: ~ C'l/ t--: ~ "v, ,~ "''('<1, ~ , ~ , '\I ~ I ~ ~ ~ ~ ~ ") ~ ! . \~J~O, -~/j '\\ ~~ ~~~~ IT ~~- ~\ - \ ~ '<. -, '-I- .??./{.'1 ~0 ~ City of Wheat Ridge Community Development Department Memorandum TO: Darin Morgan FROM:'fMeredith Reckert SUBJECT: Building permit - 3363 Jay Street DATE: January 13,2004 The memorandum is in regard to the building permit application for single-family addition and "pop- top" at 3363 Jay Street. The site plan submitted with the permit uses a scale of 1 centimeter = .15 foot. The site plan needs to be resubmitted in a scale that is conventionally used in the industry. It should delineate existing and proposed improvements with measurements from property lines. The elevations for the structure should also show existing and proposed improvements and measurements. N A o 100 Feel > f 1 DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE. 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number: Date: '1':' ,. '".,. 10424 4/24/00 Property Owner: Property Address: 3363 Jay St Contractor License No. : 20371 Company: Jenesis Roofing, LLC OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Phone: 303-202-5261 Phone: 303-972-9636 Construction Value : Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibili for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Whea dg 0 Inanees, for work under this permit (OWNER)(CONTRACTOR) SIGNED Use: , DATE <r-Z<t-Q:l Total: Description: Nail over old roof BUILDING DEPARTMENT USE ONLY SIC: Sq. Ft: Approval: Occupancy: Roof: Stories: Residential Units: Walls: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date : Approval : Expiration Date : Approval : $1,550.00 $57.05 $0.00 $23.25 $80.30 This permit was issued in accordance with the provisions set forth In yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and BulldlnQ Code of Wheat RldiJe, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authonzed is not commenced within sixty (60) days from Issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceedllng with successive phases of thel' 00. The Issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (1) (2) (3) l~l (6) Chief Building Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: APPUC.t\TID N Property Owner: Property Address: Contractor License No. : Kon..\ ~T, I \ -=Te(\h,'!,,"::, -::S:c~i 'Sf-, Phone: 31J3--;?o;}..-S-?c,) >(' OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGRE MENT Company: 33&3 ;)0371 =:re Phone: 3D3 ~'5'9-IS-oS'- Construction Value: /53 C;, co Permit Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abi by all conditions printed on this application, and that I assume full responsib" or c mpl' I the Wheat Ridge Building Code (U.B.C.) and all other applicable W at dg or,' S, fa WQ der this permit. Total: (OWNER)(CONTRACTOR) SIGNED E if - ~ '1-(11) Use: Description: f1q"( Ouer 010 y;;oo~ BUILDING DEPARTMENT USE ONLY ~ Approval: Zoning: SIC: Sq. Ft: Approval: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date : Approval: Expiration Date: Approval: Expiration Date: Approval: (1) (2) (3) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and BUilding Gode ofVVheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of om~...half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural now of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of thel'ob. The issuance of a permit or the approval 0 drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (4) (5) (6) Chief Building Inspector