Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4100 Jay Street
From: no-reolvCalci.wheatridae.co.us To: CommDev Permits Subject: Online Form Submittal: PERMIT APPLICATION Solar PV Installation Date: Sunday, June 12, 2022 5:53:18 PM CAUTION:This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Report any suspicious activities to the IT Division. PERMIT APPLICATION Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 4100 Jay Street Property Owner Name Justin Adams Property Owner Phone 310-344-9568 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email LIC00247585 Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business CJR Partners LLC dba Sopris Solar Name Wheat Ridge 180308 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-954-0463 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email utility1@soprissolar.com Address Retype Contractor utilityl@soprissolar.com Email Address DESCRIPTION OF WORK Scope of Work 4.68 solar pv installation KW 4.68 # of Panels 11 Location of Panels house roof Structural required Yes Upload engineer letter Adams Residence Wheatridae CO PE Calcs or pages on 8 1/2" X Stamped 124202213558 ndf 11" only Solar Installation Plan Adams Residence Wheatridae CO PE Calcs Set on 11 "X17" only. Stamped 124202213558_1 ndf Project Value (contract 15000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Sasha Blouin Pe rm it I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: _ Job Address: �-'� Permit Number: ��� �C� ❑ No one available for inspection: Time; ,• - AM/PM Re -Inspection required: Yes IVa` When corrections have been made, call for re -inspection at 303-234-5933 Date: ' i ' 1 � Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �' t-? C! Job Address: `-i CJ 0 Permit Number: h'1 i?. u ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes I When corrections have been made, call for re -inspection at 303 -234 - Date: L Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201901469 PERMIT NO: 201901469 ISSUED: 07/17/2019 JOB ADDRESS: 4100 Jay St EXPIRES: 07/16/2020 JOB DESCRIPTION: Tear off 1 layer on pitched portion, reroof with asphalt shingles, 4/12 pitch; 26 squares total *** CONTACTS *** OWNER (310)344-9568 ADAMS JUSTIN D SUB (303)466-0161 BERNIE REITZ 019543 REITZ ROOFING, INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / EARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,500.00 FEES Total Valuation 0.00 Use Tax 136.50 Permit Fee 156.75 ** TOTAL ** 293.25 *** COMMENTS *** *** CONDITIONS *** ALL PITCHED ROOFS REQUIRE A MIDROOF INSPECTION REGARDLESS OF PITCH. FOR ROOF PITCH 6/12 AND OVER: Midroof & Final Roof inspections for ROOFS with 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with Building Division Policy BD -18-001 for Balanced Ventilation Systems, or manufacturer installation instructions, whichever is more stringent. MIDROOF & SHEATHING: Effective December 1, 2014, asphalt shingle installations require an approved mid -roof inspection, conducted when 25-75% of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75% of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. LADDER MUST BE SET FOR ALL ROOF INSPECTIONS: A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. COMMERCIAL ROOFS: In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201901469 PERMIT NO: 201901469 ISSUED: 07/17/2019 JOB ADDRESS: 4100 Jay St EXPIRES: 07/16/2020 JOB DESCRIPTION: Tear off 1 layer on pitched portion, reroof with asphalt shingles, 4/12 pitch; 26 squares total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications= applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this pen It. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original_permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief AMg ciaf'-1"`"" Date REQUESTS MUST BE MADE BY :59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Kimberly Cook �o t q From: no-reply@c i.wheatridge.co.us Sent: Wednesday, July 17, 2019 2:03 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Kim Residential Roofing Permit Application This application is exclusively for new RESIDENTIAL roofing permits and for licensed contractors only. Permits are processed and issued in the order they are received. You will be notified if your contractor's license or insurance has expired. The license and insurance must be current before the permit will be processed. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. The Building Division permit counter is open from 7:30 am to 3:30 pm, Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a RESIDENTIAL reroof permit? How many dwelling units are on the property? Yes Single Family Home PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address 4100 Jay St. Justin Adams 310-344-9568 kdb714@gmail.com Do you have a signed Yes contract to reroof this property? CONTRACTOR INFORMATION Contractor Business Reitz Roofing, Inc. Name Contractor's License 019543 Number Contractor Phone 3034660161 Number (enter WITH dashes, eg 303-123-4567) Contractor Email Address reitzroofinginc@gmail.com Retype Contractor Email reitzroofinginc@gmail.com Address REQUIRED: Credit Card 4100 Jay St..pdf Authorization Form DESCRIPTION OF WORK TOTAL SQUARES of 26 the entire scope of work: Project Value (contract 6500.00 value or cost of ALL materials and labor) Are you re -decking the No roof? Is the permit for a flat Pitched roof (2:12 pitch or greater) roof, pitched roof, or both? (check all that apply) What is the specific pitch 4:12 of the PITCHED roof? How many squares are 26 part of the PITCHED roof? Describe the roofing 30 Year Dimensional Shingles materials for the PITCHED roof: 2 Type of material for the Asphalt PITCHED roof: Provide any additional Tearing off (1) layer on sloped section only - excludes flat detail here on the section description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Yes Yes Yes Yes Yes 3 Person Applying for Bernard Reitz Permit Email not displaying correctly? View it in your browser. i CITY OF WHEAT FRIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE {{�� Inspection Type: Job Address: r Permit Number: Q, .r ❑ No one available for inspection: Ti f 4_C_(A PM -1 Re -Inspection required: Yes CIS When corrections have been made, -cafffor re -inspection at 303-234-5933 Date`s&- y Inspe o . -- _� DO NOT RE VE THIS NOTICE z.� r: A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax 44119- U(,)�IfFncLl INSPECT [V N T�CE acs- r{l�� 1�c� . Inspection Type: yv 7 ` t` Ana wn2 n Job Address: Li/ 0 0 .� S Permit Number: '9 0 18 0,3? & S D ec ❑ No one available for inspection: Time )t1= ® ) ASPM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: Gf a N 1 Inspector: DO NOT REMOVE THIS NOTICE PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Plumbing PERMIT - 201900024 201900024 4100 Jay St Residential water line repair -new 3/4 meter pit to crawl space of home. ISSUED: 01/07/2019 EXPIRES: 01/07/2020 inch copper water main line from *** CONTACTS *** OWNER (310)344-9568 ADAMS JUSTIN D SUB (720)556-5531 Jason Wilkat 190004 Big Apple Plumbing & Heating *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,200.00 FEES Total Valuation 0.00 Use Tax 88.20 Permit Fee 125.05 ** TOTAL ** 213.25 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** City of Wheat Ridge Residential Plumbing PERMIT - 201900024 PERMIT N0: 201900024 ISSUED: 01/07/2019 JOB ADDRESS: 4100 Jay St EXPIRES: 01/07/2020 JOB DESCRIPTION: Residential water line repair -new 3/4 inch copper water main line from meter pit to crawl space of home. I, by m signahire, do hereby attest that the work to be performed shall comply with all accompanying approved plans and' applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am leggally authorized to include all entities named within this document as parties to the work to be performed and that a�l work to be pertonned is disclosed in this document and/off its' accompanying approved plans and specifications. acs! S nature of OWNER or CONTRACTOR VCircle one) Date f' This permit was issued bas oration provided in the permit application and accompanying pians and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2.This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180. days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original pernrt fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and � procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. Theismuance orgranf of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any ap �61 c de ora rdinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat dge COMMUNITY DEVELOPMENT Building & Inspection Services 7500 W. 291 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: i /I/P"I Plan/Permit # Plan Review Fee: Building Permit Application *** Complete all applicable highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: �d 1 bo Property Owner (please print): �;;5�� � Phone:)�� Property Owner Email: `1 c I&I Y-"\ 5�� ((�`v_t�CC�c lu✓-" (O'n Tenant Name (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer E-mail: Contractor Name: City of Wheat Ridge License #: l 91tO aq Contractor E-mail Address: le For Plan Review Questions & Comments (please print): Phone: Phone: CONTACT NAME (please print): J�c(, �,S i ka Phone: x,3,0 - 5-y (a ' S 5-3 1 CONTACT EMAIL(p/ease print):�� e �e-0 i r e'J C + Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields, if applicable. ❑ COMMERCIAL ® RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. bNkkw\ 9QaLq 0\'�Glyxe Cy-)r.eck .,k ��je CbUlellk. Sq. FULF BTUs iU2w �ayse apfer "oe. Gallons z ',U Amps Squares For Solar: KW # of Panels Requires Structural For Commercial Projects Only: Occupancy Type: Construction Type: _ Occupancy Load: Square Footage: Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ y a6b OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) CONTRACT R) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): 1 DATE: Printed Name: :a5o a ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 1' r D' r4 a +-,r e r r G� Job Address: S4 - Permit Number: £1 /,Z 0 - g D ❑ No one available for inspection: Time = 3 V CR/PM Re -Inspection required: Yes Nom' When corrections have been made, call for re -inspection at 303 -234 - Date: t� / q Inspector: —b DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection IDivision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTI N NOTICE 3 � ) - 1 p ;P:- re (� a a rj Inspection Type: 3-d0 - 1'�)rt� it,^ /1 `~c re k, Job Address: i -I 1 Q O Permit Number:i� , f 6�tich -)�U&� ❑ No one available for inspection: Time C1 = 2)9 �VI YPM Re -Inspection required: (e No When corrections have been made, call for re -inspection at 303-234-5933 Date: Va F3 lJq Inspector: `-?" DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: _�o r hOR Job Address: i Permit Number: ❑ No one available for inspection: Time 1023 C) AM/PM Re -Inspection required: Yes oNo When correct' ns have been made, call for re -inspection at 303-234-5933 ail I Date:! �A Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division �(303) (303) 234-5933 Inspection line 235-2855 Office ® (303) 237-8929 Fax INSPECTIOON OTICE Inspection Type: �1� ? d ;� Job Address: _ Wod %_ Permit Number: O 6 S O r-- ❑ No one available for insptition: Time �1h AM/PM Re -inspection required: es ° N p q 1 0 When correct"ons have been made, call for re -inspection at 303-234-5933 Date: / 7 / Inspector: O NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 3—a j,�tlr�,'n�a Job Address: 8100 7a t4 St, Permit Number: 70062 660 ✓ata ❑ No one available for inspection: Time AM/61 Re -Inspection required: Yes /IN" When corrections have been made, call for re -inspection at 303-234-5933 Date: -11/7/10 Inspector: 60,1 e, Ldy- '- DO NOT REMOVE THIS NOTICE City of Wheat Ridge Homeowner Interior Remodel PERMIT - 201802680 PERMIT NO: 201802680 ISSUED: 10/11/2018 JOB ADDRESS: 4100 Jay St EXPIRES: 10/11/2019 JOB DESCRIPTION: Converting mud/laundry room into second bathroom with laundry area; create wall to with laundry on one side and bathroom on the other; new plumbing and electrical, new sewer drains tied into existing ; 66.64 sq ft total *** CONTACTS *** OWNER (310)344-9568 ADAMS JUSTIN D *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,500.00 FEES Total Valuation 0.00 Plan Review Fee 101.89 Use Tax 136.50 Permit Fee 156.75 ** TOTAL ** 395.14 *** COMMENTS *** *** CONDITIONS *** I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. If professionals are hired, those contractors are licensed with the City of Wheat Ridge and are listed on the permit. Consultations and inspections will only be performed with the homeowner of record present. All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. .> City of Wheat Ridge Homeowner Interior Remodel PERMIT - 201802680 PERMIT NO: 201802680 ISSUED: 10/11/2018 JOB ADDRESS: 4100 Jay St EXPIRES: 10/11/2019 JOB DESCRIPTION: Converting mud/laundry room into second bathroom with laundry area; create wall to with laundry on one side and bathroom on the other; new plumbing and electrical, new sewer drains tied into existing ; 66.64 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this pen -nit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed an t t all work to be performed is "disclosed in this document and/or its' accompanying approved plans and specifications. VV kkvx �C)O_1M, �C)lll` 2_0QT n ture of OWNER or CONTRACTOR (Circle one) Date T is permit was issued based on the information provided in the permit application and accompanying plans and specifications and is s bject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. his permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made -be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. The issua or granting permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicab de any or ante or regulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City o W heat Ijge COMMUNITY D[vGLOPMGNT Building & Inspection Services Division 7500 W. 291' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Permits(o)-ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Lo / Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Propertv Owner �\lam 3-t . w�k� ac\,V--A S Property Owner Email: Q r �.� ��'' U L Tenant (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address: L11 City, State, Zip: S-A . Architect/Engineer E-mail: Contractor: City of Wheat Ridge License #: Contractor E-mail Address: For Plan'Review Questions & Comments (please print): Phone: Phone: S Phone: CONTJ4CT NAME (please print): Phone: �� b 3�I cl S V CONTACT EMAIL(p/ease print): C,)c-xks �- U[,S� CA \,Y\ • Sub Contractors (Must provide Wheat Ridge LiZense'No.) Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License #' Other City Licensed Sub: Other City Licensed Sub: City License # City License # ❑ COMMERCIAL [✓]RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. -Tur►���I. �Xi4'��'�` iM��C l l,�'-�t�c�d' ���r� i�'�c� a. �.t���j [3c��rc�c�, .NI y\��`� � 1 J l �! ' I W Q y(r)b1M uCST �4 f LLP � p ✓ V'�I\\wu- ��G� CA -%i ClN �l„ � scr CG.S� i\C11 ��� \1�Ci1�1 vV�P7QY �tS1i�1i W�J� 11 bQ yt��, SIN burn 51�� �a��s w � C SUppt`� U 1L -A Sq. Ft./LF BTUs Gallons Amps Squares Project Value: (Contract value or the cost of all materials and labor included in the entire project) a 15, Wo'10 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (0WNER)) (CONTRA CTOR) r (AUTHOR/ZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): V 1"� ( DATE: 1 Cl2 20\,S Printed Name: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION "S CONSTRUCTION TYPE: 2ir1r`� Reviewer: !' BUILDING DEPARTMENT COMMENTS: la0A two #1 "—^# -Ci J � �/� ✓ "�` Reviewer: —rb PUBLIC WORKS COMMENTS: Reviewer: Building Division Valuation: t 40 $-!�O City of Wh6atPjd +� COMMUNITY DEVELOPMENT Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property.' Property Owner(s): `1451 VCU.y"� S Project Property: 1M) '�o_`\ �W_OA V_A �6b03 Project Type: � V\ Y-C'ON ) � \- �� d signature of Applicant StaWof Colorado ) County of ) ss The foregoing instrument was acknowledged by me this day of dll/ , 208 by 1 �k& Notary Public WAYNELICRADO017742[:BRIDGET APRIL 24. 2022 My Commission Expires/20�� City of See attached list for additional requirements that Whcat1kjAe apply to this project. COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Review is limited to the contents of the plans submitted and any errors or omissions contained herein shall not be construed as permission to allow any conditions to exist in violation of the codes of the City of Wheat Ridge Rough Framing and Wood Requirements The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough heat and ventilation are complete. The building should be fully enclosed with the roof covering and siding in place. 2 Fire blocking shall be installed to cutoff all concealed draft openings in the following locations: (IRC 302.11) A. In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor levels, and at 10 -feet horizontal intervals. B, At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, and cove ceilings. C. In openings around vents, pipes, ducts, cable, wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. D. In concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the run of the stairs at unfinished walls. 18 There shall be a floor or landing on each side of each exterior door, except where a stairway with 2 or fewer risers located on the exterior side of the door, other than the required exit door, a landing is not required for the exterior side of the door. The landing must be no lower than 73/ -inches below the top of the threshold of the door provided the door does not swing over the landing. (IRC R311) 19 Stairways must be at least 36 -inches in width. Handrails shall not project more than 4% -inches. The maximum rise may not exceed 7% -inches. The minimum tread depth may not be less than 10 -inches. Minimum headroom is 6 -feet, 8 -inches. For stairways with solid risers a nosing of %-inch to 1% -inches shall be provided. When open risers are used the opening between the treads shall not allow the passage of a 4 -inch sphere to pass through. Landings must be provided at the top and bottom of the stairway that is the width of the stairway measuring at least 36 -inches in the direction of travel. Handrails shall be provided on at least one side of stairways with 4 or more risers and ramps with a slope exceeding 1:12. Handrails shall be mounted 34 -inches to 38 -inches above the nosing of the treads. Handrails must be continuous for the entire length of the stairs and provided with a minimum space of 1% -inch between the wall and the handrail. Ends shall be returned or terminate in newel posts or safety terminals. See the requirements and more information. (IRC R311.7.8.2) 20 Handrail Grip Size Shall Be:A. Circular Handrails: 1% -inch to 2 -inches perimeter. B. Non -Circular: 4 -inches to 6% -inches perimeter with a maximum cross section of 2% -inches. C Perimeter Dimension Greater than 6% - inches: shall have a finger recess on both sides. 21 Guards must be provided for porches, screened porches, balconies, fixed seating and raised floorcMaces more than 30 -inches above the floor or grade below. Guards must have a minimum height of 36-ir gjtVtW@9 sides of stairs with a total rise of more than 30 -inches above the floor or grade below shall have guards not less. guildtn9 p!'J&J0n than 36 -inches high. Intermediate rails shall not allow the passage of a 4 -inch sphere. (11312) Window fall protection must be provided for window openings less than 24 inches above the finished floor and more than 72 inches above grade or surface below. (R312.2) 22 Safety glazing shall be installed in the following hazardous locations and be permanently labeled as safety or tempered glazing: glazing panels in doors; glazing enclosing spas, bathtubs or showers; glazing panels adjacent and within 24 -inches of the edge of a door; glazing panels greater than 9 square feet within 18 -inches of the floor; glazing used for railings; glazing used for barriers for swimming pools and spas; and glazing enclosing stairways, landings, and ramps within 36 -inches horizontally of a walking surface. See the Boulder County Land (IRC R308) Heating and Ventilation Requirements 32 Bathroom exhaust fans shall exhaust directly to the exterior and must be provided in bathrooms where windows of at least 3 square feet are not provided. The mechanical ventilation must be capable of providing an exhaust capacity of 50 cfm intermittent or 20 cfm continuous exhaust. (IRC R303.3, M1507.4) 33 Appliances and equipment shall be installed in accordance with the conditions of their listing. Manufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1, M1401.1,(M1902.2) 34 Appliances shall be accessible for inspection, service, repair and replacement without removing permanent construction. 30 -inches of working depth and width shall be provided in front of the control side of an appliance. (IRC M1305.1) 35 Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407) Electrical Requirements 36 All hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical connection at the time of rough inspection. 37 Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at least 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through the fixture into the ceiling cavity. (IRC NI 102.4.5) 47' Tamper -resistant Receptacle outlets are required in every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14) 48 Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above tkmyttof tl counter top and spaced so no point exceeds 24 -inches from an outlet. B. Island and peninsula counte ea�Ri89e length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet. C. At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. Building Division 49 At least one receptacle outlet must be installed in each laundry, basement, attached garage and detached garage with power. F. At least one receptacle outlet that is accessible while standing at grade level and located not more than6-feet, 6 -inches (1981 -mm) above grade, shall be installed outdoors at the front and back of each dwelling unit having direct access to grade. Balconies, decks, and porches that are accessible from inside of the dwelling unit and that have a usable area of 20 square feet. 1. Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet within25-feet of the equipment. G. Hallways 10 -feet or more in length. 50 Two 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining area. At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch circuit shall supply laundry. (IRC E3703.2, E3703.3, E3901) 51 Ground fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the following locations: bathrooms, garages, unfinished grade level accessory buildings, at exterior locations, crawlspaces, unfinished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks, boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location. (IRCE3902, E3902.11) 50 Combination type Arc -Fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch circuit outlets in Receptacle outlets are required in every family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, hallway, closets, and similar dwelling areas. (IRC 3902.12) 51. At least one wall switch -controlled lighting outlet shall be installed in every habitable room, bathroom, hallway, (10ft) stairway, attached garage, detached garage with electric power, and at the exterior side of each outdoor egress door having grade level access. Attics, under floor spaces, utility rooms and basements containing equipment or used for storage must be provided with a switch 52 Smoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring operated light. (IRC E3903)with battery backup and shall be interconnected so the actuation of one alarm will activate all alarms in the dwelling unit. Smoke alarms shall be installed in the following locations: (IRC R314) A. In each sleeping room; B Outside each sleeping area in the immediate vicinity of the bedrooms; and C. One on each additional story including basements. 53 Carbon Monoxide alarms are required in a single-family dwelling that has fuel -fired appliance(s), or a fireplace, or an attached garage. The alarm must be installed within 15 -feet of the entrance to each sleeping room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and has a battery backup. They may be combined with a smoke -detecting device if the combined device complies with applicable law. (IRC R315) 54 Clothes closet lighting shall be limited to surface -mounted or recessed incandescent fixtures with completely enclosed lamps, and surface -mounted or recessed fluorescent fixtures.Surface mounted fixtures shall be installed on the wall above the door or on the ceiling with the following clearances between the fixture and the nearest point of a storage space: (IRC E4003.12)A. Incandescent fixtures or LED shall have a minimum 12KcM clearance. B. Fluorescent fixtures shall have minimum 6 -inch clearance. Recessed fixtures shall be installed in the wall or ceiling with the following clearances: A. Recessed incandescent fixtures shall have a miniNLN&g Ridge inch clearance to the nearest point of storage. B. Recessed fluorescent fixtures shall have a minimurrE64pogDivision clearance to the nearest point of storage. 55 Working space must be provided around energized equipment for servicing and maintenance. The minimum dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the equipment. Working space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2) 56 Electrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or accumulate n wiring compartments or other electrical parts. Fixtures installed in wet locations must be labeled "suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations" or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8, E4002.9,(E4002.10, E4003.9, E4003.10,E4003.11) Plumbing Requirements 58 DWV systems shall be tested on compellation of the rough piping installation by water or for piping system other than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed .1) Water test 10 feet above the highest fitting connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes. 2) Air test shall maintain 51bs of pressure for 15 minutes. 59 Piping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1) 60 Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb threshold not less than 1 -inch below the sides and back of the receptor. The curb shall measure a minimum of 2 -inches to a maximum of 9 -inches above the top of the drain. (IRC R307, P2708, P2709) 61 The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, and lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 62 Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or CSAB125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 120°. (IRC P2708.3,P2713.3) City of 63 Shower doors shall have safety glazing; hinged show door shall open outward. (11308.4.5, P2708.1) Wheat Ridge 64 Backflow prevention must be provided to prevent contamination of potable water. This includes but is not Building Division limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers. Backflow device must be inspected and approved by a 3rd party agency. (IRCP2902.2, Table P2902.3, P2717) Insulation 65 R-20 Walls R-49 Ceiling R-19 Crawlspace Window U -Factor .32 Floor R-30 66 Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum R-6. ( N 1103.2. 1) 67 Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. (G2426.4) Class I or II vapor retarders are required on the interior side of the insulation in framed walls, floors and roof/ceilings of the building's thermal envelope. The vapor barrier is not required in construction where moisture or freezing will not damage the materials, or where the framed cavity (or space) is ventilated to allow moisture to escape. A vapor retarder is not recommended on a concrete basement foundation wall or in a shower /bath compartment (IRC 702.7, R702.7.1). Wallboard Requirements 68 The garage shall be separated from the residence and its attic by materials of not less than %-inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5 8 -inch Type X gypsum board. Where the separation is a floor -ceiling assembly, the structure supporting the separation shall also be protected by not less than %-inch gypsum board. (IRC R302.6) Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in thickness, solid or honeycomb core steel doors not less than 1 -inch thick, or 20 -minute fire -rated doors. Openings are prohibited between garages and rooms used for sleeping. (11302.5.1 )Doors between attached garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be self-closing and self -latching. 70 Nail spacing for gypsum board % gypum board Ceiling 16oc, 7", nails 12", Type S screws % wall spacing 24"OC, 8" nail spacing. 12"OCscrews. 5/8 ceiling board 16"OC, 7"nails 12"spacing, screws 240C 8". 72 Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic the or other required nonabsorbent finish material shall conform to ASTM C1396, C1178 or C1278. It is permitted on ceilings where framing spacing does not exceed 12 -inches o.c. for %-inch thick or 16 -inches o.c. for 5 8 -inch thick gypsum board. Water-resistant gypsum board shall not be installed over a vapor retarder in a shower or tub compartment and may not be used where there will be direct exposure to water, or in areas of continue%., high humidity. All cut and exposed edges shall be sealed. (IRC R702.3.8) Wheat Ridge Building Division WAN OLS' �' E�'1t�R�0 y S'` �-��i6�► i i r.) ls" 0(- L C"._ sex to i Ce.rlito�y \4 Doli c c 8 O tet, City or what R'as:Je "ti/din S division of Wheat COMMUNITY DEVELOPMENT n pne-n� irtl Reviewed for Code Cotnpi:ance I� Plata Esamkw Date MdMkTwp'Me asua rota Oerme or approval ofv+am %pwfleatwu wdmnpatatlom Awnat be a Pern.rtfil . or an Owoval of. any viotatbn to &W CY the Plowsiam Of the balldinp code w of anY City wdmoMf Pry tf Drosambp to OW outhorMY to violate of cancel the prov+sioM of the SwAd.V COM or other Ordeionces of the City Jhall not be volid. 8 O tet, City or what R'as:Je "ti/din S division " 1 vv)e - /T7 joUtRRU kUSt LN\J\ovT FA 66klk IU b 2 ,\6�A2 �® 0 -0- ��LUL (\6- i I e�o()� City of Wheat Ridg isi n Building Div s A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: '405'_- F"/ -)Cl /i le c 11 Job Address: c o y S4 Permit Number: a o i S a -d -7 ❑ No one available for inspection: Time Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: `� a 61//'9 Inspector: Tb DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Mechanic PERMIT - 201801027 PERMIT NO: 201801027 ISSUED: 04/12/2018 JOB ADDRESS: 4100 Jay ST EXPIRES: 04/12/2019 JOB DESCRIPTION: Add on 2 ton AC system and Rinnaci tankless water heater. 13 seer, 2 ton and Rinnai high efficiency. *** CONTACTS *** OWNER (310)344-9568 ADAMS, JUSTIN SUB Jim Morse 100067 Mountain Breeze Heating & Air SUB Mark Modglin 060127 Adept Elect & Constr. Serv. LL *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,620.00 FEES Total Valuation 0.00 Use Tax 160.02 Permit Fee 172.60 ** TOTAL ** 332.62 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2012 IRC & 2014 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by m signature, do hereby a st that the work to be performed shall comply with all accompanying approved plans and specifications, applica e building codes, and I ap ica le municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the le al owner of the prop an a authorized to obtain this permit and perform the work described and approved in conjunction with this e it. I her a e f at m le y authorized to include all a tities named within this do ment as parties to the work to be p rform d and t t a I t e per o ed is disclosed in this docum nt and/or its' acc pang' g approved plans and specifications. L i� I Sig ature of TOWNEi or ON OR (Circle one) Date 1. This per it was issued based on the information provided in t e permit application and accompanying ptans and specifications and is subject tuthe compliance with those documents, and all appli able statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance r ardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granti f a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any appli� code ora ,kinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY City of ]Wh6at Midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits( a�ci.wheatridge.co.us FOR OFFICE USE ONLY Date: gll,7 // gS Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: .� N Y Property Owner (please print): Property Owner Email: Tenant (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor: A-v)'flnA i Phone: v 4 City of Wheat Ridge License #: Phone: Phone: Contractor E-mail Address:iy�hE��z��PQ�iIIQavk. atl-L" LAIVUL'e aW� --" -off For Plan Review Questions & Comments (please print): CONTACT NAME (please print): LU " Z- Phone: S �'t cl 1-{ 3e�� CONTACT EMAIL(p/ease print): 7klLV U�Iu�;�� P— LoflAl i I �C,�>IA^ Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: Mechanical: Ty C' � I -�/ � � W.R. City License # W.R. City License # r \ C Q Other City Licensed Sub: Other City Licensed Sub: City License # City License # ❑ COMMERCIAL TKfRESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, tc. "llo p Commercial Projects Only: Occupancy Type Sq. Ft./LF Amps BTUs Squares Construction Type: Gallons Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) Signature (first and last name): Printed Name: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer. PUBLIC WORKS COMMENTS: Reviewer: REPRESENTATIVE) DEPARTMENT USE ONLY (OWNER) (CONTRACTOR) DATE: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Building Division Valuation: 0 I�l e13t-t 3 INSPECTION RECORD INSPECTION REQUEST INF- iini) r Occupa- - Va7 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter r._-- Underground/Slab Inspections Date Inspector Comments - - - - Inspector Initials Initials Electrical Sewer Service Plumbing Rough Inspections Date - - - - Inspector Initials - - 1+••••••• v. .11� r%5JWVC Ilia Cl.UV115 Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof 1i Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *Fnr Inw w%oIno nnrmr+c _ DIS. - G,.. ..--------- ----- ---�--- `• •••�• •vuZI - �oV� wl IJ W V i V1I IFIIGL-,U IIum Uiu Fire uistnci ana electrical low voltage by the Building D Division. **For Inspection Time Window — Please email insptimerequest@Ci.wheatridge.Co.US by 8:00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge Residential Roofing PE�_1.��� IERMIT NO: 201701343 ISSUED: 06/01/2017 "OB ADDRESS: 4100 Jay ST EXPIRES: 06/01/2018 "OB DESCRIPTION: Remove 1 layer house and garage; reroof 1 story Tamko Heritage 30 year; 9 squares ply modified - 33 squares ** CONTACTS *** )WNER (303)521-0360 ROWEN LEO SUB (303)466-0161 Bernie Reitz 019543 Reitz Roofing, Inc. ** PARCEL INFO *** ;ONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / "** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,900.00 FEES Potal Valuation 0.00 Jse Tax 207.90 Permit Fee 204.30 ** TOTAL ** 412.20 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k1/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€lms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. PERMIT. - C�'� �'� 3t� ADDRESS: -c ��� JOB CODE:L,6111, INSPECTION REC�RC Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date ql4nitWs MFoundation / Piers P.E. Lettern Setback Cert. ls n wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Comments CommentQ Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan DateI Inspector Initials SEE OVER FOR ADDITIONAL INSPECTIONS Comments K3 In ector Date p Comments )ugh Inspection (continued) Initials 6 Rough Mechanical Residential 7 Rough Mechanical Commercial 18 Boiler / Furnace 19 Hot water tank 20 Drywall screw and Nail 21 Moisture board / shower walls 22 Rough Grading 23 Miscellaneous Inspector Comments :final inspections Date Initials 402 Gas Meter Release t03 Final Electrical Residential 104 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof r 410 Final Window/Door Inspections from these entities shall be requested 411 Landscape/Park/Planning one week in advance. 412 Row/Drainage/Public Works For landscaping and parking inspections please 413 Flood plain Inspection call 303-235-2846 414 Fire Insp. / Fire Protection For ROW and drainage inspections please call 303-235-2861 415 Public Works Final For fire inspections please contact the Fire 416 Storm Water Mgmt. Protection District for your project. 417 Zoning Final Inspection 418 Building Final inspection re Note: All items must be completed and uedroved by Approval lof the Planning, Public nspe'ctionndoes not before a Certificate of Occupancy is constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. City of Wheat Ridge Resid. Windows/Doors PERMIT -201707838 PERMIT NO: 201707838 ISSUED: 09/29/2017 JOB ADDRESS: 4100 Jay ST EXPIRES: 09/29/2018 JOB DESCRIPTION: Permit to install 13 windows, same size same locations. No changes to appearance. *** CONTACTS *** OWNER (310)344-9568 ADAMS, JUSTIN SUB (720)697-6131 Andrew Chambers 130049 Vivax Pro Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,463.69 FEES Window Replacement 50.00 Total Valuation 0.00 Use Tax 156.74 ** TOTAL ** 206.74 *** COMMENTS *** *** CONDITIONS *** Windows shall comply with all applicable codes, have a .32 or better U -factor and shall be safety glazing if within a tub enclosure, less than 18 inches above the floor or within 24 inches of a vertical edge of a door. I, by my signature, do hereby attest that the work to be performed shall comply with all accompany in� approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be per ed a d that alt work to be performed is disclosed in this docume t and/ its accompanying approved plans and specifications. Sign um of OWNER or CONTRACTOR (Circle one) Date This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and re6eived prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offiial and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division, 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of t is jurisdiction. Approval of work is subject to field inspection. � gUTAIE i Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheatl die COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cDci.wheatridge.co.us FOR OFFICE USE ONLY Date: ��z� 1' � Plan/Permit # 1-C-) 1.7 0-7 F3 o' Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address:-� Property Owner (please Property Owner Email: '\ 0-6 a- V`�s j C U S 6\ woo Mailing Address: (if different than property address) Address City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Ph �-ry . 3\o S'0 9S& Contractor: V 1 V 4. US Contractors City License #: I -) c00' l Phone: 3O`3 U l O Contractor E-mail Address: 0 4 -fop's . Co� 14 Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL E RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 1% W or� Ow -- 3 &),WQ S- i 2- -Q- � 0 CL--�- Osvk Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) L1 V -J . OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZEtD REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature first and last name ).�\r DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ �c' -- -- -- — - - Detailed Quote -- -- - J CTB Vivax Pros * , 1050 Yuma St 10 Denver, CO 80204 y 720-331-9735,�� info@vivaxpros.com Project Information rProject-. Justin Adams Project ID: 60 Sales Rep: Administrator Created Date: 08/23/2017 Delivery / Pickup: Delivery Modified Date: 09/05/2017 Print Date: 09/05/2017 Customer: Justin Adams PO: Adams -Employee Terms: Est. Delivery: Comments: (After Receipt of Order) ---------- Billing Information — --- Shipping Information — Customer Name: ------- ------- ------ TJobsite Contact: Address: Address: Customer Phone: Fax: Email: Contact Phone: Fax: (Select Preference) Email: Manufacturer: Milgard Item: 0005 Location: #1 Living Room Quantity: 1 Tuscany, 8220T, SH, Net 35 1/2" x 49 3/4", UF: 0.3, SGC: 0.28, VLT: 0.53 181.65 1/8" SunCoat Low -E Bottom Only Tempered and 1 /8" Clear Bottom Only Tempered 33.25 Gas Filled: Argon 6.30 Item Total: $ 221.20 Clear Opening W: 32 1/2" H: 20 3/8" SQ: 4.60 Item Quantity Total: $ 221.20 J Fin Placement: 1 3/8" Setback; Horizontal Vent Set: 25 1/8"; Vent Height: One Half; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Tempered: Bottom Only; Outer Glass Lite Option: XSunCoat Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 1/8"; Glass Thick 2: 1/8'; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; STC: 29 CPD: MIL -A-225-05186-00001 Line Item Comments: Customer Approval: Initials Quote ID: 60 1 Of 6 09!0512017 Manufacturer: Milgard Item: 0006 Location: #2 Living Room Quantity: 1 Tuscany, 8120T, DV, Net 68 1/8" x 49 3/4", UF: 0.31, SGC: 0.28, VLT: 0.53 331.10 Gas Filled: Argon 11.90 Item Total: $ 343.00 Clear Opening W: 14 5/16" H: 46 3/4" SQ: 4.65 Item Quantity Total: $ 343.00 X X Fin Placement: 1 3/8" Setback; Vertical Vent Sets: One Quarter; Custom Vertical Vent Sets: 17 3/16"; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Outer Glass Lite Option: SunCoat — -- Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 3/32"; Glass Thick 2: 3/32"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; CPD: MIL -A-224-05131-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0007 Quantity: 1 X Location: #3 Bed 1 Tuscany, 8120T, HV, Net 51 11/16" x 49 3/4", UF: 0.31, SGC: 0.28, VLT: 0.53 Gas Filled: Argon Clear Opening W: 23 5/16" H: 46 3/4" SQ: 7.57 Fin Placement: 1 3/8" Setback; Sliding Direction: XO; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 3/32"; Glass Thick 2: 3/32"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; CPD: MIL -A-224-05131-00001 Line Item Comments: 227.50 9.10 Item Total: $ 236.60 Item Quantity Total: $ 236.60 Customer Approval: Initials Manufacturer: Milgard Item: 0008 Location: #4 Bed 1 Quantity: 1 Tuscany, 8220T, SH, Net 35 5/8" x 49 3/4", UF: 0.3, SGC: 0.28, VLT: 0.53 181.65 1/8" SunCoat Low -E Tempered and 1/8" Clear Tempered 66.85 Gas Filled: Argon 6.30 Item Total: $ 254.80 Clear Opening W: 32 5/8" H: 20 3/8" SQ: 4.62 Item Quantity Total: $ 254.80 Fin Placement: 1 3/8" Setback; Horizontal Vent Set: 25 1/8"; Vent Height: One Half; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Tempered: All; Outer Glass Lite Option: SunCoat X Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 1/8"; Glass Thick 2: 1/8"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; STC: 29 CPD: MIL -A-225-05186-00001 Line Item Comments: Customer Approval: Initials Quote ID: 60 2 Of 6 09/05/2017 Manufacturer: Milgard Item: 0009 Quantity: 2 Location: #5, #6 Bedroom 2 Tuscany, 8120T, HV, Net 35 11/16" x 37 5/8", UF: 0.31, SGC: 0.28, VLT: 0.53 Gas Filled: Argon Clear Opening W: 15 5/16" H: 34 5/8" SQ: 3.68 Fin Placement: 1 3/8" Setback; Sliding Direction: XO; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 3/32"; Glass Thick 2: 3/32"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; CPD: MIL -A-224-05131-00001 Line Item Comments: 163.45 4.90 Item Total: $ 168.35 Item Quantity Total: $ 336.70 Customer Approval: Initials Manufacturer: Milgard Item: 0010 Location: #7 Bathroom 1 Quantity: 1 Tuscany, 8120T, HV, Net 35 7/8" x 25 3/8", UF: 0.31, SGC: 0.28, VLT: 0.53 137.90 1/8" SunCoat Low -E Tempered and 1/8" Matelux (Obscure) Tempered 66.50 Gas Filled: Argon 3.50 Item Total: $ 207.90 Clear Opening W: 15 3/8" H: 22 3/8" SQ: 2.39 Item Quantity Total: $ 207.90 X Fin Placement: 1 3/8" Setback; Sliding Direction: OX; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: Matelux (Obscure); Glass Thick 1: 1/8'; Glass Thick 2: 1/8"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; STC: 29 CPD: MIL -A-224-05132-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0011 Location: #8 Laundry/Bath 2 Quantity: 1 Tuscany, 8120T, HV, Net 35 5/8" x 24 5/8", UF: 0.31, SGC: 0.28, VLT: 0.53 137.90 1/8" SunCoat Low -E Tempered and 1/8" Clear Tempered 33.60 Gas Filled: Argon 3.15 Item Total: $ 174.65 Clear Opening W: 15 1/4" H: 21 5/8" SQ: 2.29 Item Quantity Total: $ 174.65 X Fin Placement: 1 3/8" Setback; Sliding Direction: OX; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Tempered: All; Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 1/8"; Glass Thick 2: 1/8"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; STC: 29 CPD: MIL -A-224-05132-00001 Line Item Comments: Customer Approval: Initials Quote IO: 60 3 Of 6 09/0512017 Manufacturer: Milgard Item: 0012 Location: #9 Laundry/Bath 2 Quantity: 1 Tuscany, 8120T, HV, Net 52 3/8" x 37 5/8", UF: 0.31, SGC: 0.28, VLT: 0.53 202.30 1/8" SunCoat Low-E Tempered and 1/8" Matelux (Obscure) Tempered 142.10 Gas Filled: Argon 7.00 Item Total: $ 351.40 Clear Opening W: 23 5/8" H: 34 5/8" SQ: 5.68 Item Quantity Total: $ 351.40 Fin Placement: 1 3/8" Setback; Sliding Direction: XO; Exterior Finish: X White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Tempered: All; Outer Glass Lite Option: SunCoat Low-E; Inner Glass Lite Option: Matelux (Obscure); Glass Thick 1: 1/8"; Glass Thick 2: 1/8"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; STC: 29 CPD: MIL-A-224-05132-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0013 Location: #10 Bed 3 Quantity: 1 Tuscany, 8120T, HV, Net 55 1/2" x 32 5/8", UF: 0.31, SGC: 0.28, VLT: 0.53 185.50 1/8" SunCoat Low-E Right Only Tempered and 1/8" Clear Right Only Tempered 34.30 Gas Filled: Argon 6.65 Item Total: $ 226.45 Clear Opening W: 25 3/16" H: 30" SQ: 5.25 Item Quantity Total: $ 226.45 X Fin Placement: 1 3/8" Setback; Sliding Direction: XO; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Tempered: Right Only; Outer Glass Lite Option: SunCoat Low-E; Inner Glass Lite Option: Clear; Glass Thick 1: 1/8"; Glass Thick 2:1/8"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; STC: 29 CPD: MIL-A-224-05132-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0014 Location: #11 Bed 3 Quantity: 1 Tuscany, 8120T, HV, Net 35 5/8" x 37 3/4", UF: 0.31, SGC: 0.28, VLT: 0.53 163.45 Gas Filled: Argon 4.90 Item Total: $ 168.35 Clear Opening W: 15 1/4" H: 34 3/4" SQ: 3.68 Item Quantity Total: $ 168.35 Fin Placement: 1 3/8" Setback; Sliding Direction: XO; Exterior Finish: White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Outer X Glass Lite Option: SunCoat Low-E; Inner Glass Lite Option: Clear; Glass Thick 1: 3/32'; Glass Thick 2: 3/32"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; CPD: MIL-A-224-05131-00001 Line Item Comments: Customer Approval: Initials Quote ID. 60 4 Of 6 09/05/2017 Manufacturer: Milgard Item: 0015 Location: #12 Family Room Quantity: 1 Tuscany, 8120T, HV, Net 35 3/4" x 37 3/4", UF: 0.31, SGC: 0.28, VLT: 0.53 163.45 Gas Filled: Argon 4.90 Item Total: $ 168.35 Clear Opening W: 15 5/16" H: 34 3/4" SQ: 3.70 Item Quantity Total: $ 168.35 Fin Placement: 1 3/8" Setback; Sliding Direction: XO; Exterior Finish: X White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 3/32"; Glass Thick 2: 3/32"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; CPD: MIL -A-224-05131-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0016 Location: #13 Family Room Quantity: 1 Tuscany, 8120T, HV, Net 51 5/16" x 49 5/16", UF: 0.31, SGC: 0.28, VLT: 0.53 227.50 Gas Filled: Argon 9.10 Item Total: $ 236.60 Clear Opening W: 23 1/8" H: 46 5/16" SQ: 7.44 Item Quantity Total: $ 236.60 Fin Placement: 1 3/8" Setback; Sliding Direction: XO; Exterior Finish: X White; Interior Finish: White; Glazing: Dual Glazed (Insulated Glass); Outer Glass Lite Option: SunCoat Low -E; Inner Glass Lite Option: Clear; Glass Thick 1: 3/32"; Glass Thick 2: 3/32"; Spacer Type: EdgeGard; Gas Filled: Argon; Screen: Standard with Fiberglass mesh; CPD: MIL -A-224-05131-00001 Line Item Comments: Other Charges: Customer Approval: SUBMITTED BY: SUB TOTAL (taxable):$ 2926.00 ACCEPTED BY: SUB TOTAL (non-taxable):$ 0.00 TAXES( 0.000 %):$ 0.00 DATE: GRAND TOTAL:$ 2926.00 Notice (if any): For warranty information please visit www.milgard.com/care-and-warranty/ Please note that actual NFRC energy values may vary from those reported in CTB quote due to variations that may occur during the manufacturing process. In most cases variations will be minimal. Please contact your Milgard location with questions or concerns regarding this potential variation. Handing is viewed from outside looking in "X" indicates operable panel. "0" indicates fixed panel. 13 items. Quote ID: 60 5 Of 6 09/05/2017 ADDITIONAL INFORMATION: This Quote is valid for 30 days. This is an estimate only and does not include delivery charges. I understand that this order will be placed according to these specifications and is non-refundable. Quote ID: 60 6 Of 6 09t05J2017 j i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE J Inspection Type: Z-//jO/ Job Address: eAZO Permit Number: -?D/ %O7K_—sK ❑ No one available for inspection,: -Time p�M/PM) Re -Inspection required: Yes �No When corrections have been made, call for re -inspection at 3�03-234-5933 Date:-//' �' % l Inspector: JeW6/ DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE / Building Inspection Division (303) 234-5933 Inspection line v (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:I _ Job Address: wo 0 Permit Number: Z C)/ `; C% 13 �l 3 No one available for inspectioq�Time f ` JAM/PM Re -Inspection required: YesNo ,i When corrections have been made, call for re -inspection at303-234-5933 / ! j fes`'' / Date: C0 Inspector: :i DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �61it•j rZ. Job Address: Z/-'/00 Permit Number: 2-0/90 1}'--5-6- Re -Inspection required: Yes No * When c9pections have been made, cr re -ins e4 on at.303-234-5933 I' Date: ! Inspector:: DO NOT REMOVE 'fkS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201701343 PERMIT NO: 201701343 ISSUED: 06/01/2017 JOB ADDRESS: 4100 Jay ST EXPIRES: 06/01/2018 JOB DESCRIPTION: Remove 1 layer house and garage; reroof 1 story Tamko Heritage 30 year; 9 squares ply modified - 33 squares *** CONTACTS *** OWNER (303)521-0360 ROWEN LEO SUB (303)466-0161 Bernie Reitz 019543 Reitz Roofing, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,900.00 FEES Total Valuation 0.00 Use Tax 207.90 Permit Fee 204.30 ** TOTAL ** 412.20 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€ms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201701343 PERMIT NO: 201701343 ISSUED: 06/01/2017 JOB ADDRESS: 4100 Jay ST EXPIRES: 06/01/2018 JOB DESCRIPTION: Remove 1 layer house and garage; reroof 1 story Tamko Heritage 30 year; 9 squares ply modified - 33 squares I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that Ian the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that 11 wor to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Da I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new pennit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, tees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgei.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of WheatR i�dge MUNiTy DEVELOPMENT Building & Inspection Services Division 7500 W. 29"' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: Plan/Permit # l') -/ a 611 Plan Review Fee: Building Permit Application Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed.'"' Property Address: Owner Property Owner Email: S e CD T� CD cam; Mailing Address: (!f different than property address) Address: City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor: 1�_ f z i Z Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # C,I- Plumbing: W.R. City License # Phone• -- S -C) /- 0,?,G Phone:'3— 4/6 6 > c0 / 6 lL Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form De_ s, r&22Zof Work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, Proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, We and amount of materials to be used, etc.) � oq 0 co Sq. FtJLF Btu's Gallons Amps Squares Oe/�` — Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $--� a 9 50�. OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby cem fy that the setback distances proposed by this pp regulations of the City of Wheat Ridge or covenants, easements or restrictions s of record; tion are accurate all measurements o not violate applicable and dallegatiorules or n made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner. of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) ar (AUTHORIZED. SENTATIV) of (OWNER) (CONTRACTOR) PRINT NAME -J I l°t't C1 t� (•-Z SIGNATURE: e ., , DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: Reviewer: OCCUPANCY CLASSIFICATION: BUILDING DEPARTMENT COMMENTS: Reviewer PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received Water District ❑ Received Sanitation District ❑ Received ❑ Not Required ❑ Not Required ❑ Not Required Building Division Valuation- S ' City of Wheat Ridge Residential Electric PERMIT - 201701356 PERMIT NO: 201.701356 ISSUED: 06/01/2017 JOB ADDRESS: 4100 Jay ST EXPIRES: 06/01/2018 JOB DESCRIPTION: Electrical service upgrade - 200 amps *** CONTACTS *** OWNER KAMBY NORMA JEAN SUB (720)219-1383 Scott Berkman 080190 Current Installations *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,250.00 FEES Total Valuation 0.00 Use Tax 47.25 Permit Fee 93.35 ** TOTAL ** 140.60 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or . CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. Thfs permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new pen -nit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to geld inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of het�'C C�7�tMt1Pw [`fY I7EVE LC?PMLN T Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(a)ci.wheatridge.co.us FOR OFFICE USE ONLY J Date: Plan/Permit # ae P) 3S V Plan Review Fee: Building Permit Application **' Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. " Property Address: Owner Property Owner Email: Mailing Address: (if different than property address) Address: II,� � Z�iA� iOktf , State, Zi Architect/Engineer Architect/Engineer E-mail: Contractor: ( U r Ion -5 Phone: Phone: Contractors City License #: 0Q �� Phone: 70 `7 _ g`1 ff Contractor E-mail Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License# Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. Ft./LF Amps L/CJD Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ Z�t O C OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of'Mieat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility forcompliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided o lication. CIRCLE ONE. (OWNER) r AU RIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Signature (first and last name): DOTE:, ❑ I understand that checking this box, that I acknowledge that this constitutes a legal signature. ZONING £OMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS, Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION - Building Division Valuation: $ A CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ll(Il Job Address: % Permit Number: 2 ®� EQNo one available for inspection: Time AM/PM Re -Inspection require Yes o *When corrections have been made, call for re-inpe tion at 303-234-5933 Date: Inspector: DO NOT REMO 5 THIS NOTICE 4' CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: �) � 0 Job Address: 4—) i 0 v & J� 'f r Permit Number: v i 7 0 f '3 q- ❑ No one available for inspection: Time i 6'7 b AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Ca G. e-) Date: Inspector: DO NOT REMOVE THIS NOTICE a d d ed Sq. FUL.Ft S STUS »w.» x :w Cred Ca f v w « ® © «... :edit card ?« w ¥ +« 2 «° ?> 9 Print narne� INSPECTION RECORD OccupancVITVpe 'v - INSPECTION LINE: (303) 234 -5933 F Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. INSPECTOR MUST SIGN ALL $PACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR COMMENTS: INITIALS - Footings /Caissons Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic. Weatherproof / French Drain - Sewer Service Lines Water Service Lines - CONCRETE SLAB FLOOR - Electrical (Underground) Heating ROUGHS -- Sheathing Lath / Wall tie Mid -Roof C 33' . 9 Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical - ABOVE INSPECTIONS TO BE SIGNED PRIOR TO PROCEEDING Framing Insulation ** NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZA TION OF CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY Drywall Screw FINALS flectricaf Plumbing Mechanical Roof Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. ** NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZA TION OF CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY UGGUPANCY`NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED .. _ :- - .Do.Fl &CP`T *Tj.JIC !`/CD11YDllAA TLJC \A /G AT4IGR i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: L 1 DO . C` Permit Number: Q_-)~ ? ? t- . fa - ❑ No one available for inspection: Time/ 3? AMIPM ,N Re-Inspection required: Yes 1 'When corrections have been made`calJlforre-inspection at 303-234-5933 r Date: l I of i)ql Inspector: ~ p LL, ( DO NOT REMOVE THIS NOTICE ♦ i . CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: J JJ Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, cafi fforil l 'sp tion at 303 234-5933 Date: C~ a3 CP ~Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: McgOP' Job Address- 4) 0 O TAY S-7- Permit Number: 09 ?i 47_2> COk ~1t tz- F-LA-51~!A16 ( Va f~1r ~3aG T ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, call for r,0 inspection at 303-2345933 Date:/A_-,)'7 _p c~ Inspector: b~ /C DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 093493 PERMIT NO: 093493- '.ISSUED:.: 10/20/2009 JOB ADDRESS: 4100 JAY ST 1EXPIRES: 04/18/2010 DESCRIPTION: Reroof28 sqs ***CONTACTS owner 303/421-5961 Norma Kambry SUB 303/761-6400 J. Bretz 01-8118 Excel Roofing, Inc:' PARCEL INFO ZONE CODE: UA =USE: UA SUBDIVISION: 0396 'BLOCK/LOT#: 0,/ FEE SUMMARY ESTIMATED PROJECT VALUATION: :.7,065.00 FEES Permit Fee 199.30 Total Valuation ,pp t Use 'Tax 127.17 . **TOTAL 326.47 Conditions: 5 nail installation & mid-roof inspection required:. Board sheathing spaced more .hana 1/2 of an inch apart requires plywood overlay on entire roof. Ice and water shield required from eave edge to 21 inside exterior walls. e**Contractor/Property owner shall j provide ?ladder(s) secured in place for npsections. Subject to field inspection. I hereby certify, that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,' rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegationsmade are accurate; that I have 'read and agree to abide by all conditions. printed on this application and that Iassume full.` responsibility for 'compliance with the Wheat 'Ridge Building Code [(I.B.C) and all other appI able Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. signature of contractor/owner idat This permit was issued in accordance with the, provisions set forth in your application and is subject to the laws of the State of Colorado and to. the zoning Regulations and Building Codes; of Wheat Ridge, Colorado or any other applicable ordinances of the City." This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have. been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one l(1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for anew permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job'. The issuance of a permit: or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, an violation of the provisions of the building codes or any other ordinance, law,: rule or regulation. All'. plan ev ~tbject to field inspections. ignature c Chi Building :Official date NSPE!WON REQUEST LINE: (303)234-5933 BUILDING OFFICE:: (303)235-2855 EQUESTS MUST BE -MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ? 10/19/2009 17:50 303-761-6442 EXCEL ROOFING INC 105-3y o w"r City of Wheat Ridge Building Division m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 Inspection Line: 303-234-5933 Property Address: Property Owner (p/ee Mailing Address: (If q!fferent than property address) Address: PAGE 05/06 Date: Plan Permit #-'M City, state, Zip: Contractor: Q- q.A l O a: Sob Contractors: Electrical City License M Company: Plumbing City License Mechanical City License Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval; Approval: /t ry CL. construavon'Xratme: $ . Use of space(description): (ascalcyla6etl.:pertlyegWtdlnrJvaluation 0'at¢slteal) Description of work: en•.Revlew,'(tYU.e.a6time efsubmillail: S ptw+~sl Sq. FUL.Ft added: Squares ~ BTU's Gallons Amps OWNEWCONTRAGTOR SIGNATURt Cr uN V~rca I wl.~,nv..~.r-.nom^~- I hereby certify that the setback distances l,roposed by-06 permitappllcetion are atldure rules or regulations of the City of Wheat R I have read and agree tor blde 4 all dconditi ons grin allegations m per ade de are accurate; that untllh onsIb m sll per for Plans subject to field Inspect ongullding Code (l..C) and all other a CIRLCE ONE:: (OWNER) (CO ) or PERSONALAEPRESENTATIVEof PRINT NAME: y-.,~ w SIGNATURE; DEP'ARTM!ENT' USE ONLY ZONING COMMENTS; Zoning: Reviewer: PUBLIC WORKS COMMENTS: Reviewer; and do not violate applicepie ordinances, acord; that all rhaasuremarifs shown, and on this application end that I assume run Inme.l Rim. ordinances. for work (OWNER) (CONTRATOR) Date; OCCUPANCY:- BUILDING DEPARTMENT COMMENTS: Reviewer: FIRE DEPARTMENT:: 0 apprOVed w/ Comments 0 disapproved 0 no ravluw required Bldg Valuation: Building Permit Application COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - (303-234-5933) CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) Building Permit Number: 16744 Date: 2/24/2004 Property Owner: JOE KAMBY Property Address: 41 00 JAY ST Contractor License No.: 18383 Company: Harper Services Phone: 421-5961 Phone: 670-3048 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge \!~ances, for work under this permit. (OWNER)(CONTRACTOR)SIGNED \~ ~ DATE '- Total: $10,500.00 $253.90 $0.00 $126.00 $379.90 Description: STEEL SIDING Use: 7"':>.0,0 c<MJ\ lfW~15~.~ BUILDING DEPARTMENT USE ONLY Zon.~ Approval: Zoning: B~~ SIC: Sq. Ft.: Approval: _....,,'1!'-8P_~;.:;~liII .~~yqWlal!!!f.u.H.LU_ Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job. The i.~. ua a~e approval of drawings and specifications shall not be construed to be a pennit for. no, an appcoval ot. any violation of the Provis~/ej / I;s or any other ordinance, law, rule or regulation. j ~ Chief Building Insjfector Please sign Terms and Conditions on reverse side of page. (1) (2) (3) Building Permit Number: Dale: APPLlCA TJON -.so c \L",-",,-\o, .Ij /00 :S-lA'1 <; ~ . \ 't,?b '7 t\",--\~~ 5"'__~v__c.e> Phone: 303-LjZ/- :r'1'-1 Property Owner: Property Address: Contractor License No.: Company: Phone 30J--C:~70 -JOi'~ OWNER/CONTRACTOR StGNATURE Of UNOERSTANOtNG AHO AGREEMENT I hereby certify that the setback distances proposed by lhis perm~ application are accurate. and do not viola\!! applicable ordinances, ru~ Of regulattons of the City 01 Wheal RK1ge or covenants, easements or restrictions of record; that al measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions plinted on this application and that I assume tun responsibility for compliance with the W'heat Ridge 8uikiing Code (U.8.C) and aU other applicable Wheal Ridge Ordinances, lor work under this permit IOWNERHCONTRACTORJ.SIG~~4, ~ DATE z/2':>'/D'f Construction Value: $ /0,500 Permit Fee: $ Plan Review Fee: $ Use Tax: $ (OWNER)(CQNTRACTOR): PRINTED DATE Total Fee: $ DESCRtPTtON: 5+,,-"-.--\ ~~'\ BUILDtNG DEPARTMENT USE ONLY SIC SqH: ZOHD+G COMMENTS: Approval: Zoning: BUIlOIHG COMMUHS: Approval: Puauc WORKS COIIIIEHTS: Approval: I CGccpancy Electrical License No: Company: \\!t::1S ~C:'0f ~~t,~, :es Res;den~i,ll Uni\s: Plumbing License No: Company: Mechanicat License No: Company: bpiration Date: Approval: bpiration Date: Approval: bpi ration Date: Approvat: (1) Thb IMIfnlIlwaslnued WI KCClf'dMttwldJ the provItk>>As HI. forttl ill your appliatlon and Is subJect 10 1tI. Uws of ItIt StaI. ofCoklra6o and to lb. Zonktg R.,ulations Iftd BuIJcIIftg Codes of WhNl Ridge, Cokndo 01 any odw ~ onIinancn oIlbt CJty. (21 Thh pennI.. up,." (A) the wortI. autboftud Is not commtn<:tc1 wIIhin strty (60) daY' from ;.SU. dll. or (9) the buikIng audtortztd.. wspMCkd or abandoMd for . ......011""..... (3) ...... ,.". G,*", . ft_ J*"d: may be ~ tor I .. of on.......ItI. amoulrt nonndy ~, providtd no ch"'geI hlV' bMn or wiI bt mMI. WI lb. original plaIl. aM~' IItd 1ft)' sutptn'" or abucIonlfltftt hI' not u~ OM (1) y_, . cl\angn hive bMft or" ....,..,... or Ib~ uCM<tl on. (1) ,.... fuI.... thai be pakI tor I ft_""'" (4) No waR of Illy mann.- ... be doD.1bIt wiI c:bange.... nllblnl now of wll... CluAng' drain. probhm. (51 CoftIractor .aI IKIUfy the BuAdiftt Mapedor tnnty.fow (24) hour1 In actv...c. tor .. Nasptdion. and." ~. wrilten approval Of! Naapedkm canllMfoA procMdlftg wtItl ...\UtWn phnn 01 u.e)Db. (6) The ....anet of. ptI1NI or lb. apprvval of dnwinp lAd ~n.lh. not be coMtnMd to be. pwmk for, nor an approval of, any vioIatioft of the proYiaioI!. of 1M buIcnng cod" or MY oth... cnIrlanOl, law, nJh Of Algub&rl. Chief Building Inspector , I _5___ �ao I )-O),�Sv INSPECTION RECORDOccupancy/Type INSPECTION REQUEST LINE: (303) 234-5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this Foundation Inspections Date Inspector Initials Comments Pier Concre�Encasednd (CEG) ROW & Drainage / Public Works Dept. Foundation / P.E. Letter Floodplain Inspection (if applicable) Do Not Pour Concrptp Prinr Tn Ai TI-_ w I- - r---•^• -- ■ --� r•fvvv= n1,peutivnS Underground/Slab Inspections Date Inspector Initials Comments Electrical Sewer Service Plumbing Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections [Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw / Nail Final Inspections Date Inspector Comments omments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection /Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be comp/eted and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits —Please be sure that rough inspections arP rmm��araA fn.r, *h„ �:.,. �:..._:_. __ _, ..y Ll IU uunUnKy uIVlJlon. - - c uwai ww vundye "For Inspection Time Window — Please email inSptimerequest@CLwheatridge.CO.US by 8:00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather A , City of Wheat Ridge Residential Electric PERMIT - 201701356 ISSUED: 06/01/2017 ERMIT NO: 201701356 OB ADDRESS: 4100 Jay ST EXPIRES: 06/01/2018 FOB DESCRIPTION: Electrical service upgrade - 200 amps ** CONTACTS *** )WNER KAMBY NORMA JEAN :)UB (720)219-1383 Scott Berkman 080190 Current Installations k** PARCEL INFO *** LONE CODE: UA / Unassigned USE: UA Unassigned / SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 2,250.00 FEES Total Valuation 0.00 Use Tax 47.25 Permit Fee 93.35 ** TOTAL ** 140.60 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. I by my signature, do hereby attest that the work to be performealland lywithall and that Inamn&approved own r or ns havnd e been authorized applicable building codes, and all applicable municipal codes, policies procedures, by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date pp 1 This permit was issued based on the information provided in the permit application and accompanyinglans and specifications ons and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, p procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changetion Services . of the natural flow of water without prior and sof pecigfic approval. ec 5. The permit holder shall notify pc ed or the Building onceal work and without written approval of such work from he Building sion in accordance with established andiInspect on Servicesi inspections and shall no p Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anyviolation of any provision o any applicable cod aft r`regu do ' of this jurisdiction. Approval of work is subject to feld inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line.