Loading...
HomeMy WebLinkAbout3980 Garrison StreetDocuSign Envelope ID: BCCD726B-OOEC-486F-8C4F-4685433C93EF June 23, 2021 D�NO0 LICF Subject : Structural Certification for Proposed Residential Solar Installation. vp�.•N...... NsF� Job Number: 501R-98OPEAK; Rev A.2 : �o off•• Client: Trent Peaker 3 Address: 3980 Garrison St, Wheat Ridge, CO, 80033 uSigned by: o,�Fs . .• � �c.�-9n, Q�,9u�n, S/ONAL E� Attn: To Whom It May Concern Digitally Signed on: 6/23/2023 86735A926F482... Astra v.1.44 CAT 2 Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2018 IRC/IBC/IEBC, ASCE 7-16 & 2018 NDS • Basic Wind Speed V = 107 mph, Exposure C • Ground Snow Load = 30 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary (Hardware Check Includes Uplift Check on Attachments/Fastener, Structure Check Considers Main Structure) Orientation Attachment Spacing/Canti lever Configuration GoDCRng Result R1 Landscape Portrait 64/25 48/22 Staggered Staggered 55% 71% Pass Pass Roofing Material Pitch Structure Check Comp Shingle 19° Pass Orientation Attachment Spacing/Canti lever Configuration GoDCRng Result R2 Landscape Portrait 72/28 48/22 Staggered Staggered 55% 71% Pass Pass Roofing Material Pitch Structure Check Comp Shingle 19° Pass 225 Bush St. Suite 1400 San Francisco, CA 94104 1 P (949)383-0993 Harvest the Sunshine Higher output Power * Lower LCOE ® Less shading and lower resistive loss * Better mechanical loading tolerance supxlor wamanry * 12 year product warrants * 25 year linear power grant warranty ®®®®® Is C 61730, UL 61215 UL 6173 ISO soo15m1sQuality mane emomseeme ISO 14001 2015 En,ironm enoal management "ems dress o1. mor O,c,nmlooal health anasarew manage emssem let TS 62941 2016 Terrestrial phoovelta,(av) modules — JA Linear Power Warrants 0 Induste Warrants ,onddewe in PV module design JASOLAR MECHANICAL DIAGRAMS � z )�5 f / enlarge view of ounono hole( 0 1) Remark customized frame color and cable length availal'- r=] goal JAM60S10 320-340/MRM SPECIFICATIONS Cell Mono Weight 18.7kgf3 % Dimensions 1689t2mm•996t2mm•35±1 mm Cable Cross Section Size 4mm' (12AWG) No. ofcells 120(6.20) Junction Box IP68, 3 diodes -335/MR OC 4.10 (1000V) Connector OC 4.10-35 (1500V) Cable Length Portrait:300mm(+)/400mm(-); (Including Connector) Landscape:1000mm(+)/1000mm(-) Packaging Configuration 30 Per Pallet ELECTRICAL PARAMETERS AT STC Maximum System Voltage 1000V/1500V DC(UL) Operating Temperature JAM60510 JAM60S10 JAM60S10 JAM60S10 JAM60S10 JAM60S10 TYPE -320/MR -325/MR -330/MR -335/MR Rated Maximum Power(Pmax) [W] 320 325 330 335 Open Circuit Voltage(Voc) [V] 40.60 40.87 41.08 41.32 Maximum Power Voltage(Vmp) [V] 33.73 33.97 34.24 34.48 Short Circuit Current(Iac) [A] 10.16 10.23 10.30 10.38 Maximum Power Current(Imp) [A] 9.49 9.57 9.64 9.72 Module Efficiency [%] 19.0 19.3 19.6 19.9 Power Tolerance 0-+5W Temperature Coefficient of Isc(a_lsc) +0.044%/°C Temperature Coefficient of Voc(p Voc) -0.272%/°C Temperature Coefficient of Pmax(y_Pmp) -0.350%/°C STC Irradiance 1000W/m2, cell temperature 25`C, AM1.5G Remark Electrical data in this catalog do not referto a single module and they are not part of the offerThey only serve for comparison among different module types. ELECTRICAL PARAMETERS AT NOCT Maximum System Voltage 1000V/1500V DC(UL) Operating Temperature JAM60510 JAM60S10 JAM60S70 JAM60510 JAM60S10 TYPE 320/MR-3251MR -3301MR 335/MR 340/MR Rated Max Pcwer(Pmax) [W] 241 245 249 253 257 Open Circuit Voltage(Voc M 38.05 38.26 38.46 38.68 38.90 Mm Power Voltage(Vmp) M 31.68 31.80 32.02 32.21 32.40 Short Circuit Cunerd(lsc) [A] 8.07 8,14 8.21 8.28 8.35 Max Power Cunant(Imp) [A] 7.63 7.70 7.78 7.85 7.93 NOCT Irradiance 800W/m2, ambient temperature 20`C wind speed lm/s, AM1.5G CHARACTERISTICS Current -Voltage Curve JAM60S10-335/MR m Boiju- Q c 6 v ° 2 0 o m 20 30 40 Voltage(V) 3 d Power -Voltage Curve JAM60S10-335/MR r000vvfm= 00 50 608 /m'fm 400W' a0 fi0 00 0 o m 20 30 40 Voltage(V) JAM60S10 -340/MR 340 41.55 34.73 10.46 9.79 20.2 OPERATING CON Maximum System Voltage 1000V/1500V DC(UL) Operating Temperature -40`C -+85`C Maximum Series Fuse 20A Maximum Static Load,Front 5400Pa(112 Ib/ft`) Maximum Static Load,Back 2400Pa(50 Ib/fie) NOCT 45t2`C Fire Performance Type 1 Current -Voltage Curve JAM60S10-335/MR 10 8 Q c 6 U 4 2 0 o io 20 30 40 Voltage(V) '"')smar. The RSD -S -PLC meets SunSpec requirements,maintaining normal function by continually receiving a heartbeat signal from the APsmart Transmitter. The RSD executes rapid system shutdown when the Transmitter signal is absent. Users can manually execute rapid shutdown using Transmitter breaker switch. RS Wiring Diagram ORSD-S-PLC NONE' M o' OTransmitter-PLC NOON - Olnverter NOON---- NONE OON --- _ o NONE * If the inverter includes an integrated MONO SunSpec-certified Rapid Shutdown Transmitter, EEEE remove the external transmitter -PLC in the wiring diagram. Working Schematic Diagram Vin+ VM'- APsmart 19925 Stevens Creek Blvd, Suite 100, Cupertino, CA 95014 +1 737-218-8486 1 infoCc-bAPsmartGlobal.com I APsmartGlobal.com V out+ V out - 0 Rapid Shutdown FCc (EP L J LS REV 2.0 2020-11-26 * PV1+ PV1- NOON NOON * PV2+ mom mom E NNNN PV2- NOON ■■N■ NOON *Only (+)or( -)through core NOON NONNI NOON Working Schematic Diagram Vin+ VM'- APsmart 19925 Stevens Creek Blvd, Suite 100, Cupertino, CA 95014 +1 737-218-8486 1 infoCc-bAPsmartGlobal.com I APsmartGlobal.com V out+ V out - 0 Rapid Shutdown FCc (EP L J LS REV 2.0 2020-11-26 • �04 APsmart Raising the bar in innovative DC MLPE solar power systems Meets NEC2017&2020 (690.12) requirements Executes rapid shutdown of system when Transmitter -PLC signal is absent Meets SunSpec requirements Model Input Data (DC) Input Operating Voltage Range Maximum Cont. Input Current (Imax) Output Data (DC) Output Operating Voltage Range Maximum System Voltage Mechanical Data Operating Ambient Temperature Range Dimensions (without cable&connectors) Cable Length Connector Enclosure Rating Over Temperature Protection Features & Compliance Communication Safety Compliance EMC Compliance RSD -S -PLC 8-80V 15A 8-80V 1000V/1500V -40 OF to +185 OF (-40 °C to + 85 °C) 5'x1.2"x0.6"(129 mm x 30 mm x 16 mm) Input 250mm/Output 1200mm MC4 or Customize Type 6P / IP68 Yes PLC NEC2017&2020 (690.12); UL1741; CSA C22.2 No. 330-17; IEC/EN62109-1; 2PFG2305 FCC Part15; ICES-003;IEC/EN61000-6-1/-2/-3/-4 0 All Rights Reserved REV 2.0 2020-11-26 A ® LG Energy Solution RESU10H Prime Electrical Characteristics Product Specification (112) 2021.Feb T ate EnergyCapac ity 9.8 kWh @25°C (77°F) Usable Energy Capacity) 9.6 kWh @25°C (77°F) Charge 420 to 450VDC Voltage Range Discharge 350 to 410VDC Absolute Max Voltage 595 V DC M ex. Charge/Disc harge Current 14.3A@350V Qi (for transportation and warehousing) M ex. Charge/Disc harge Power DI 5kW Peak Power(only discharging) 7kW for 10 sec. Peak Current(only discharging) 20A@370V for 10 sec. Communication Interface RS485, CAN DC Disconnect Circ bit Breaker, 40A 600Vrating Connection Method Spring Type Connector User interface LEDs for Normal and Faultoperation Protection Features Over Voltage / Over Current/ FCC Part 15 Class B Short circuit/Reverse Polarity Scalability Max.2 in parallel (T otal Energy, Max. Charge/Discharge Power) (19.2 kWh@77F(25 C), 6.6kW, 7kWfor 10 sec) IP55 • Test Conditions -Temperature 77°F (250C), at the beginning Operating Conditions Installation Location Indoor/ Outdoor (Wall -Mounted, Floor -standing) Operafing T emperature 14 to 122°F (-10 to 50°C) OperafingT emperature(Recommended) 59 to 86OF(15 to 30°C) -22 to 140°F (-30 to 60°C), acceptable fol -7 days in total Storage Temperature -4 to 113°F(-20to 45°C), acceptable forthe first 6 mos. (for transportation and warehousing) -4 to 86°F (-20 to 30°C), acceptable for 7th —12th month Humidity 5 %to 95% Altitude Max. 6,56211(2,000m) Cooling Strategy Natural Convection Certification Cell UL1642 Safety Battery Pack UL1973/CE/RCM/TUV(IEC 62619) Emissions FCC Part 15 Class B HazardousMatenals Classificafim Class9 T ransportation UN38.3 (UNDOT) Ingress Rating IP55 • Test Conditions -Temperature 77°F (250C), at the beginning of life • Usable Energy is measured under specific condition them LGC(03CPCV>b 3CP) • Product specification may change without notice 1) 98kVWh capacity DC/DC Discharge E%cterny 975%. Ambient 77°F (25°C) 2) Peak Current excludes repeated short duration (less than 10 sec of current paidern) ® LG Energy Solution Product Specification (212) Mechanical Cbaretleristics nimin ong" Dimensions Height 817mm(322"J Depth 295 mm (116 Weight 111 so 2441bs) 32.2' (817mm) 19.8' 11.8' (694mm) (295mm) Ah E LTA Residential Energy Storage Solution for North America Residential Energy Storage Solution for North America E4 -TL -US JE6-TL-US I E8 -TL -US Key Features: • UL9540 (80002581) complied Li -ion battery energy storage system with model E4 -TL -US & E6 -TL -US & E8 -TL -US • Smart inverter with BLE, optional WiFi, Ethernet, 3G / 4G cellular communication • Optional revenue grade meter (compliant with ANSI C12.20, Class 0.5) • EMS integrated with self -consumption, zero export, TOU and back-up operations • Support either DC -coupled or AC -coupled system • Support bi-directional cloud communication • Support remote diagnosis and OTA • Built-in AFCI & Rapid shutdown controller • UL 1741 SA, HECO compliant • CA Rule 21 Phase 1 & 2 & 3 compliant "JJ4 AhEMI Android/IOS APP BLE PVRSD --[1UPV2jff FD PV3_ RSD Residential Energy Storage Solution for North America Cn— — — — —Other Cloud r�5) — Utility Enterprise Systems Delta Cloud E Series F� J CAN/ RS485 HV Battery --—— — — — — —— R5485 — —— MID Rapid Shutdown I Main Load Disconnect Panel Grid Meter Critical Load Panel I Critical Load System Configuration DC Power AC Power - — — — — Communication ----- Cloud PV RSD Battery Communication AC r— Block Diagram Rev 15.3 - 06/2020 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Ah E UA Residential Energy Storage Solution for North America Model Compatible battery pack size E4 -TL -US E6 -TL -US E8 -TL -US 5 kWh to 20 kWh Nominal 1/0 power 5000 W 1) Acceptable input voltage range 350 V to 480 V 2) Nominal 1/0 current 15A Round trip efficiency (PCS Only) Peak > 97.5% Fuse rating 30A Battery terminal Absolute maximum input voltage Spring type 480 V 2) Start-up voltage 120 V Operating MPPT voltage range 50 V to 480 V Maximum input current per MPPT 12A 12 A 12A MPP tracker 3 3 3 Maximum DC/AC ratio 3) 1.35 1.35 1.35 Maximum allowable MPPT in- 2 (string) MPPT scan (Shading option) — 15min (high) 30min (default) 60min (low) DC disconnect Integrated AC PORT (ON -GRID MODE) Nominal output power @ 240Vac 3840 W 5760 W 7680 W Maximum output power @ 240Vac 4000 W 6000 W 8000 W Nominal output power @ 208Vac 3328 W 4992 W 6656 W Maximum output power @ 208Vac 3648 W 5472 W 7296 W AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Maximum continuous current 16A 24A 32A Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Adjustable power factor range 0.851 to 0.85c THD @ nominal power <3% Grid support compliance UL 1741 SA, CA Rule 21 phase 1,2, 3, HECO Revenue Grade Mete (optional) Integrated compliant with ANSI C12.20, Class 0.5 AC terminal FF - Spring type Output Pure sin -wave voltage Maximum output power 4000 W 5000 W 5000 W AC output voltage 240 Vac Maximum continuous current 16A 21 A 21 A Operating frequency range 57 Hz to 63 Hz THD @ nominal power <5% Maximum allowed crest factor 2.0 @ 4000 W 2.0 @ 5000 W 2.0 AC terminal Spring type Rev 15.3 - 06/2020 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Ah E UA Residential Energy Storage Solution for North America Model Peak efficiency E4 -TL -US E6 -TL -US E8 -TL -US 98.0% CEC efficiency 97.5 % @ 240 Vac 97.5 % @ 240 Vac 97.5 % @ 240 Vac Operating temperature range -22 °F to 149 °F (-30 °C to 65 °C) Humidity 0% to 95% Maximum operating altitude 9,843 ft (3,000 m) Audible noise < 45 dB(A) @ 3 ft (1 m) MECHANICAL DESIGN mor— Dimensions (W x H x D) 16.7 x 23.2 x 5.9 in (425 x 590 x 150 mm) Weight 4) 41.9 lbs (19.0 kg) 44.8 lbs (20.3 kg) 45.7 lbs (20.7 kg) Cooling Natural convection Enclosure material Display Die-casting aluminum LED indicators Communication interface BLE, optional WiFi, Ethernet, 3G / 4G cellular communication Protocol Modbus - RTU Ethernet (optional) Standard (support IPv4) emote diagnose/monitoring Bi -direction through cloud Remote firmware update Through cloud (optional) STANDARDS Battery safety UL 1973 / UL 1974 (Optional depends on battery pack) Enclosure protecting rating Type 4 Safety UL 1741, CSA- C22.2 No. 107.1-01 Software approval UL 1998 Grounding fault protection UL 1741 CRD Anti-islanding protection IEEE 1547, IEEE 1547.1 EMC FCC part 15 Class B AFCI UL 1699B (Type 1), NEC 2017 690.11 Rapid shutdown protection NEC 2017 690.12 5) Rapid shutdown transmitter Optional pre-installed 6) Grid support regulation UL 1741 SA, California Rule 21 phase 1 & 2 & 3, HECO Compliant Energy storage system certification UL 9540 Standard warranty 1 10 years 1) Adjustable value, limited by the output capability of battery pack 2) Adjustable value, limited by the maximum allowed voltage of battery pack 3) Please refer to technical note for detailed string configuration 4) Without weight of revenue grade meter 5) Compliant with APS rapid shutdown system or Tigo rapid shutdown system 6) Optional pre-installed with APS rapid shutdown transmitter or Tigo rapid shutdown transmitter Delta Electronics (Americas), Ltd. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: Inverter.Sales@deltaww.com Support Email: Inverter.Support@deltaww.com Sales Hotline: +1-877-440-5851 or+1-626-369-8021 Support Hotline: +1-877-442-4832 A&E Support (Intl.): +1-626-369-8069-80 19 Monday to Friday from 6am to 6pm PST (apart from Holidays) www.Delta-Americas.com Rev 15.3 - 06/2020 @ Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. AhELTA Residential Energy Storage Solution for North America OUTPUT - AC (LOAD Accessory: Microgrid Interconnect Device (MID) Features: • Optional for E series • Auto grid detection, no additional communication wire needed for control • Short transferring time (<5.0s) • Covert from 240 Vac to 120 Vac • Up to 21 A for each phase • UL1741, FCC certificated • Wall -mount with bracket Delta part number GPI00010108 Maximum AC ower output 7680 W AC output voltage Min -Nom -Max (L -L) 211 — 240 - 264 V Maximum continuous output current @240V 32 A Charge battery from AC (if allowed) Yes Typical nighttime power consumption <5W LJTPUT-AC (BACKUP MODE) Rated AC power output 5000 W Max AC power output - surge 7680 W for 10sec with balance load AC output voltage Min -Nom -Max (L -N) 105 —120 - 132 V AC frequency Min -Nom -Max 55 - 60 - 65 Hz Max continuous output current per phase @120V 21 A Split phase imbalance(@rated power) 21 A Automatic switchover time <5 s GENERAL SPECIFIC Operating temperature range -13 OF to 131 °F(-25 °C to 55 °C) Humidity 0% to 95% Maximum operating altitude 9,843 ft (3,000 m) above sea level Installation Wall mounting Enclosure protection rating Type 4 MECHANICAL DESIGN Dimensions (W x H x D) 9.2 x 14.9 x 5.9 in (232 x 378 x 150 mm) Weight 30.2 lbs (13.7 kg) Cooling Natural convection Compatible wiring gauge AWG 10 to AWG 6 Certification I UL 1741, CSA -C22.2 No. 107.1-01 Rev.04. 02/2019 - All information and specifications ... --. _.... , „e without notice Docuslun Envelope IF SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION SOLAR MODULES PVT 0 COVER SHEET • SYSTEM SIZE.850OW DC, 7680WAC • ALL WORK SHALL COMPLY WITH 20181RC/IBC/IEBC, MUNICIPAL CODE, AND ALL -MODULES .(25)JA SOLAR. JAM60S10-34CMR MANUFACTURERSLISTINGS AND INSTALLATION INSTRUCTIONS. SE SERVICE ENTRANCE PV -20 SITE PLAN -INVERTERS (1) DELTA ELECTRONICS. E8 -TL -US • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. •RACKING. SNAPNRACK RLU RL UNIVERSAL, SPEEDSEALMP MAINPANEL PV -30 LAYOUT TRACK ON COMP, SEE DETAIL SNR -DC -00436 • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV -31 MOUNTING DETAIL • ENERGY STORAGE SYSTEM (1) LG CHEM. RESU 10H •RAPIDSHUTDOWN(25)APSMART RSDSPLC ROOFTOP 'PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY SP SUB -PANEL SNR MOUNT MODULE LEVEL RAPID SHUTDOWN DEVICE GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 69035. SNR MOUNT &SKIRT PV -32 REPAIR DETAIL PV -4.0 ELECTRICAL LC PV LOAD CENTER • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703/61730 ® CHIMNEY PV -50 SIGNAGE SUNRUN METER City of •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1]41. mewPM DEDICATED PV METER ATTIC VENT MUN111,�Ga • RACKING CONFORMS TO AND IS LISTED UNDER UL2703. 0 FLUSH ATTIC VENT APPROVED • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II INV INVERTER(S) o PVC PIPE VENT MODULES ARE CLASS A FIRE RATED. Reviewed lar Cotle Compliance AC AC DISCONNECT(S) ® METAL PIPE VENT 0 • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL DC CONDUCTORS ARE WITHIN THIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T -VENT F 75 9x191 DISCONNECT(S) NECT(S) 0 Plans Examiner Date I? SATELLITE DISH • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 69031(6). t eMR awm.eumnov vnW �wexoe•.mvvld.nw, uenwaMwn nowmnm IO COMBINER BOX [Ez FIRE SETBACKS • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. ��� mYe/we poHslwu of Me Anpwg [WeerM%YGb u0lma[aa WqM ENERGY STORAGE: peamrenp wgxe ommirym warear✓icw p.poruo-u gxwµrg0y mdwarelnwo�amws./weuryanouwtnebgr. • 1046 AMPS MODULE SHORT CIRCUIT CURRENT. SYSTEM HARDSCAPE MD M ICRO GRID •1634 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)&690.8 (b)]. INTERCONNECT DEVICE —PL— PROPERTY LINE • PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). INTERIOR EQUIPMENT EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE BP BACKUP LOADS PANEL F-1 STERTORHOWN DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION • ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540. AM APPELMETERJ� COMMUNICATION • ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING WIRES ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH NEC ]06.30 SWLE NTS A AMPERE AND EXCEPTION 1 NEC706 30 (A). �� • ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE ENERGY AC ALTERNATING CURRENT STORAGE DEVICE INPUT AND OUTPUT TERMINALS ARE MORE THAN 5 FT FROM CONNECTED EQUIPMENT, OR WHERE THE CIRCUITS FROM THESE TERMINALS AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP PASS THROUGH AWALL OR PARTITION PER 706](E). COMP COMPOSITION • LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP DC DIRECT CURRENT EC#]080, ME #600088 _ -�- -- CIRCUIT WRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY (E) EXISTING qme� ADDITIONAL OUTLETS OR DEVICES PER NEC 21012(D). ESS ENERGY STORAGE SYSTEM P°`OOfp°1Hi1 9 F.THE a CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR EXT EXTERIOR CUSTOMER RESIDENCE. f # C a n n M GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION INT INTERIOR _�. $FIELD ' -�`� a EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE71015AP MAG MAGNETIC TRENT PECKER - w4611, ALL PASSTHROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8 MSP MAIN SERVICE PANEL SON ST, WHEAT (N) NEW R3980 IDGE CO , 80033 RIDGE, 9 n q NTS NOT TOSCALE ,esWv� KYPLING .-' oC ON CENTER TEL(720)301-8132 19Pletre'&pazeFie&11811 so Joe's Care � ^"` 2 PRE -FAB PREFABRICATED PSF POUNDS PER SQUARE FOOT APN/TMK#APN 23526 DIN N PV PHOTOVOLTAIC PROJECT NUMBER. _ r`e+mvi E n j zjn Aqualified person must be present at the time ofa PVelectrical inspection RSD RAPIDSHUTDOWN DEVICE 501RR80PEAK TL TRANSFORMERLESSWMNAve DESIGNER. (415)580.8820 ex3 Andersa s 1 Licensed master or oume man electrician, 1 Y TVP TYPICAL V VOLTS CHASE NORTHROP a 2) Residential wireman W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET 3) NABCEP-certified solar installer capable oftestingthe rapid shut down systeh REV .A2 6/232021 39, Wheat Ridge, CO 80033, DSA W41SI A'a PAGE PV -1.0 Middle School DocuSign Envelope ID: BCCD726B-OOEC-486F-8C4F-4685433C93EF SITE PLAN - SCALE = 1116" = 1' (E) GATE F+ L� PL d (E) DETACHED STRUCTURE F'[ P4 Pz A� A� ROOF PATHWAYS (3' TYP) e11 A eV NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED ON EACH MODULE PER NEC 690.12 NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: • TOTAL ROOF SURFACE AREA: 3671 SQFT. • TOTAL PV ARRAY AREA: 452.7 SQ FT. • PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREAITOTAL ROOF SURFACE AREA)' 100= 12.3% DocuSign Envelope ID: BCCD726B-OOEC-486F-8C4F-4685433C93EF ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD: 3 PSF Name Type Height Type Detail Configuration Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 30 PSF SPEED: AR -01 COMP SHINGLE - RLU 1 -Story 2X6 RAFTERS 13' - 3" 16" RL UNIVERSAL, SPEEDSEAL TRACK ONWIND 5' - 4" 2' - 1" 4' - 0" 1' - 10" STAGGERED 107 MPH 3 -SEC GUST. COMP, SEE DETAIL SNR -DC -00436 S.S. LAG SCREWS: RL UNIVERSAL, SPEEDSEAL TRACK ON 5/16": 2.5" MIN EMBEDMENT AR -01 COMP SHINGLE - RLU 1-Stor y 2X6 RAFTERS 13' - 3" 24" COMP, SEE DETAIL SNR -DC -00436 6' - 0" 2' - 4" 4' - 0" 1' - 10" STAGGERED STRUCTURAL NOTES: • INSTALLERS TO VERIFY D1 -AR-01 -SCALE: 1/8" = V-0" RAFTER SIZE, SPACING AND PITCH: 19° SLOPED SPANS, AND NOTIFY AZIM: 222° E.O. R. OF ANY DISCREPANCIES BEFORE PROCEEDING. • IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY 1 COLLAR TIE REPAIR ROOF PLANE EDGES V, REQUIRED UNDER PV (EXCEPT VALLEYS), THEN ARRAY ATTACHMENTS NEED TO BE ADDED AND OVERHANG — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- — REDUCED WITHIN THE 12" 10'-3" 39'-211 —5'-811— 22'-4" 3'-3" - BOUNDARY REGION ONLY AS FOLLOWS •• LLOWABLE ATTACHMENT SPACING INDICATED ON 2'-9" PLANS TO BE REDUCED BY 6'-1 " j 50% 5'-4"TY P. - � O � •• ALLOWABLE OVERHANG - NDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ° 6'-7" o ATTACHMENT SPACING 6'-7" ° ° � INDICATED ON PLANS O 91-411sunrun EC #7080, ME #600088 '_41-811-,--161-9"-.'-22'-T 11'-2" 24'-6" 5525 w 56TH AVE, ARVADA, CO 80002 PHONE 805 540 7631 /I FAX 0 J CUSTOMER RESIDENCE: �Ppp0 Ll TRENT PEAKER STRUCTURAL MEMBER S Vp �,•N a 89,�.F� 3980 GARRISON ST, WHEAT CHANGE: 24" OC SPACING qj o,�.. RIDGE, CO, 80033 2; /--o Si by: EL. (720)301-8132 APN/TMK#: APN: 23526 PROJECT NUMBER: aaae7 �...NA...- CKY a 501 R-980PEAK Digitally Signed: 062321 DESIGNER: (415) 580-6920 ex3 8 CHASE NORTHROP 1 SHEET LAYOUT REV: A.2 6/23/2021 PAGE PV -3.0 SEE SITE PLAN FOR NORTH ARROW DocuSign Envelope ID: BCCD726B-OOEC-486F-8C4F-4685433C93EF SNAPNRACK RL UNIVERSAL SPEEDSEAL TRACK COMPOSITION ROOF MOUNTING 0 5/16" S.S. LAG SCRE1 EMBED 0 5/16" LAG SCREW 2-1/2" INTO THE ROOF STRUCTURAL MEMBER/RAFTER FOR TORQUE SPECIFICATIONS SEE INSTALLATION MANUAL FOAM GASKET 0 5/16" S.S. LAG SCREW 2-1/2" MINIMUM EMBEDMENT ROOF RAFTER (TYP.) ROOF ATTACHMENTS SHALL BE EMBEDDED INTO ROOF RAFTERS OR OTHER STRUCTURAL MEMBERS PILOT HOLE CENTER OF COURSE ROOF SHEATHING, UNDERLAYMENT, AND ROOFING MATERIAL (TYP.) (((���� Sunrun South LLC DESIGNER: D.RYAN snaL d- "� � E"°"E�°W�®�"'""„'° a�"","�"� DRAFTER: B.PETERSON Solar Mounting Solutions EPRINOF" E"WIT"°°T THE APPROVED BY: W.ARBUCKLE WAS TEN CONSENT OF SUNRUN SOUTH - I REVISION: 1 11/11/2019 NEW DETAIL BDP 2 7/7/2020 N000109 DR =AL TRACK R( iR SPEEDSEALTRACK SHOULD BE INSTALLED PARALLEL TO RAFTER SPEEDSEALTRACK 2-1/2" MIN. EMBEDMEN- INTO RAFTER OR STRUCTURAL MEMBER COMPLETED INSTALLATION SECTION VIEW ROOFING MATERIAL COMPLETED INSTALLATION SCALE: NTS PART NUMBER: I DESCRIPTION: SNR -DC -00436 RL UNIVERSAL, ATTACHMENT DETAIL, MOUNT DATE: 7!7/2020 SPEEDSEAL TRACK ON COMP Digitally Signed: 06/23/21 ROOF DECKING 1 sunrun EC #7080, ME #600088 5525 w 58TH AVE, ARVADA, CO 80002 PHONE 885 540 7631 FAX 8 CUSTOMER RESIDENCE: TRENT PEAKER 3980 GARRISON ST, WHEAT RIDGE, CO, 80033 TEL. (720) 301-8132 APN/TMK #: APN: 23526 PROJECT NUMBER: 501R-980PEAK DESIGNER: (415) 580-6920 ex3 CHASE NORTHROP SHEET MOUNTING DETAIL REV: A.2 6/23/2021 PAGE PV -3.1 DocuSign Envelope ID: BCCD726B-OOEC-486F-8C4F-4685433C93EF STRUCTURAL NOTES: • INSTALLATION CREW TO LOCATE BROKEN MEMBERS DURING INSTALL AND REPAIR AS SPECIFIED • COLLAR TIE REPAIR REQUIRED UNDER PV ARRAY • SIZE AND LENGTH TO MATCH THE EXISTING COLLAR TIES EQ EQ , / (6) 10d COMMON NAILS TO BE FACE NAILED FROM THE COLLAR TIE TO EXISTING RAFTER AT BOTH ENDS. 1" MIN. DISTANCE FROM EDGE OF FRAMING REQUIRED (TYP). BROKEN COLLAR TIE COLLAR TIE ELEVATION - SCALE: 1/2" = V-0" Z. Digitally Signed: 062321 izra�yrn�carrrerun:i.Zyrrzy:aanxa[:iyai.Z�a[Y:izsxiaxjay 120/240 VAC SINGLE PHASE MOMETER XC EL D2205587 UTILITY GRID LH -1 o-�, /1 EXISTING tee% NEUTRAL FEEDER DU222RB _ GROUND 200A MAIN BREAKER 3R, 60A,2P (N) 50 FEEDER BREAKER (1) 10 AWG BARE COPPER 1 BREAKER (6) 10 AWG THHN/THWN-2 NONE BUSBAR 3 (END FED) (2) 10 AWG THHN/THWN-2 NONE BACKUP 4 EXISTING LOADS PANEL (N) LOCKABLE FACILITY �� 200A (N) DELTA. GPI00010108 BLADE TYPE LOADS ~ MAIN MICROGRID AC DISCONNECT, RSD 10.46 A MAX ALLOWABLE DC VOLTAGE: PANEL /� n4 INITIATION DEVICE SYSTEM OPERATING CURRENT: 29.37 A INTERCONNECT DEVICE 501 R-980PEAK LH -1 o-�, DELTA ELECTRONICS: E8 -TL -US 7680 WATT INVERTER sowH (N) 50 SQUARE D tee% NEUTRAL FEEDER DU222RB _ GROUND eATTEHY BREAKER 3R, 60A,2P (N) 50 FEEDER BREAKER (1) 10 AWG BARE COPPER 120/240VAC AT OPPOSITE END OF (6) 10 AWG THHN/THWN-2 NONE BUSBAR 3 (N) 125A (2) 10 AWG THHN/THWN-2 NONE BACKUP 4 3/4" EMT OR EQUIV. LOADS PANEL NOTE: TOTAL PV BACKFEED = 40A FACILITY (1) 8 AWG THHN/THWN-2 EGC/GEC SYSTEM OPEN CIRCUIT VOLTAGE: USED FOR INTERCONNECTION LOADS TEL. (720) 301-8132 34.73 V CALCULATIONS 313 V DELTA ELECTRONICS: E8 -TL -US 7680 WATT INVERTER Approval Notes: 1) PN array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B) JUNCTION BOX PV MODULES JORnEQUIVALENT 1 JA SOLAR: JAM60S10-340M1R !/ (25) MODULES rh (1) STRING OF (8) MODULES (1) STRING OF (9) MODULES (1) STRING OF (8) MODULES 3 (25) APSMART RSD -S -PLC MODULE (N) HEAVY DUTY LEVEL RAPID SHUTDOWN DEVICES SAFETY SWITCH AND TRANSMITTER -PLC g (1) ENERGY STORAGE SYSTEM LOAD RATED DC DISCONNECT, LG CHEM RESU 10H, IP55 RATED AFCI, REVENUE GRADE METER, RAPID SHUTDOWN AND ENERGY O STORAGE SYSTEM INPUTS SQUARE D HU361RB 3R, 30A, 60OVDC CONDUIT SCHEDULE sowH CONDUIT tee% NEUTRAL GROUND 1 eATTEHY (6) 10 AWG PV VVI RE NONE (1) 10 AWG BARE COPPER 30A FUSES Approval Notes: 1) PN array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B) JUNCTION BOX PV MODULES JORnEQUIVALENT 1 JA SOLAR: JAM60S10-340M1R !/ (25) MODULES rh (1) STRING OF (8) MODULES (1) STRING OF (9) MODULES (1) STRING OF (8) MODULES 3 (25) APSMART RSD -S -PLC MODULE (N) HEAVY DUTY LEVEL RAPID SHUTDOWN DEVICES SAFETY SWITCH AND TRANSMITTER -PLC g (1) ENERGY STORAGE SYSTEM LOAD RATED DC DISCONNECT, LG CHEM RESU 10H, IP55 RATED AFCI, REVENUE GRADE METER, RAPID SHUTDOWN AND ENERGY O STORAGE SYSTEM INPUTS SQUARE D HU361RB 3R, 30A, 60OVDC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (6) 10 AWG PV VVI RE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (6) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EGC/GEC MODULE CHARACTERISTICS JA SOLAR: JAM60S10-340/MR OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: GENERAL NOTES: • FIELD SPLICE WIRE TO APPROPRIATE SIZE FOR MANUFACTURE TERMINATION SPECIFICATIONS WHEN NEEDED. • WIRE UPSIZE AT TIME OF INSTALLATION IS PERMISSIBLE. sunrun EC #7080, ME #600088 5525 w 56TH AVE, ARVADA, C080002 PHONE 865 546 7631 FAX 6 PAGE PV -4.0 CUSTOMER RESIDENCE: TRENT PEAKER 3980 GARRISON ST, WHEAT SYSTEM CHARACTERISTICS - INVERTER 1 RIDGE, CO, 80033 340 W SYSTEM SIZE: 8500 W 41.55 V SYSTEM OPEN CIRCUIT VOLTAGE: 425 V TEL. (720) 301-8132 34.73 V SYSTEM OPERATING VOLTAGE: 313 V APN/TMK#: APN: 23526 10.46 A MAX ALLOWABLE DC VOLTAGE: 480 V PROJECT NUMBER: SYSTEM OPERATING CURRENT: 29.37 A 501 R-980PEAK SYSTEM SHORT CIRCUIT CURRENT: 39.22 A DESIGNER: (415) 580-6920 ex3 CHASE NORTHROP SHEET ELECTRICAL REV: A.2 6/23/2021 PAGE PV -4.0 DocuSign Envelope ID: BCCD726B-OOEC-486F-8C4F-4685433C93EF ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B) &WARNING THREE POWER SUPPLY SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), 706.11(A), & 706.11(B) &WARNING POWERSOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2) LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54 INVERTER 1 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53 &WARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(D)(2)(3)(c) LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), IFC 2012: 605.11.1. IFC 2018: 1204.5.3 411 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C) NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION: MULTIPLE SOURCES OF POWER SOLAR PANELS ON ROOF DC DISCONNECT (INT) ENERGY STORAGE (INT) SERVICE ENTRANCE MAIN PANEL AND PV J L INVERTER BREAKER DISCONNECT EQUIPMENT (EXT) 3980 GARRISON ST, WHEAT RIDGE, CO, 80033 PER CODE(S): NEC 2020: 705.10, 710.10 1* ► � i City of Wheat Ridge '/� Residential Solar PERMIT - 202101366 PERMIT NO: 202101366 ISSUED: 06/28/2021 JOB ADDRESS: 3980 Garrison St EXPIRES: 06/28/2022 JOB DESCRIPTION: Roof mount, flush mount, grid -tied 8.5 kW solar PV with energy storage system 25 Panels *** CONTACTS *** OWNER (7 2 0) 891-1262 PEAKER TRENT S SUB (303)577-9628 THOMAS BROOK 070159 SUNRUN INSTALLATION SRVS. INC. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,150.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/28/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: -?1 G ?- Job Address: �a Crar-r i SUS Permit Number: 010-0 2-13 �I r ❑ No one available for inspection: Time % L� AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date:- `1 f 1 U 7 \ Inspector: DO NOT REMOVE THIS NOTICE � ► � i City of Wheat Ridge Residential Remodel PERMIT - 202002334 PERMIT NO: 202002334 ISSUED: 01/20/2021 JOB ADDRESS: 3980 Garrison St EXPIRES: 01/20/2022 JOB DESCRIPTION: Complete interior remodel on first floor and basement including a new layout for both floors, replace ceilings, all windows, exterior doors ( except garage) , enlarge front door, all new plumbing fixtures, new LED lighting throughout, new skylight in new mudroom, all new finishes, replace wood burning fireplace with gas fireplace, all new appliances, siding will be painted and new brick coursing installed in select wall infills - 3,734 sq ft total *** CONTACTS *** OWNER (720)301-8132 PEAKER TRENT SCOTT GC (720)617-9658 ZACH SMITH 202267 KNOTTY IRON LLC SUB DOMINIC RODRIGUEZ 170646 SENIC ELECTRIC INC SUB (303)934-4276 CARLOS OLIVAS 170626 R&O HEATING INC SUB (303)887-6640 JACQUES LENGERICH 130250 TIGHTEN PLUMBING INC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 528,200.00 FEES Total Valuation 0.00 Plan Review Fee 21516.51 Use Tax 11,092.20 Permit Fee 31871.55 ** TOTAL ** 17,480.26 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. 1* ► � i City of Wheat Ridge '/� Residential Remodel PERMIT - 202002334 PERMIT NO: 202002334 ISSUED: 01/20/2021 JOB ADDRESS: 3980 Garrison St EXPIRES: 01/20/2022 JOB DESCRIPTION: Complete interior remodel on first floor and basement including a new layout for both floors, replace ceilings, all windows, exterior doors ( except garage) , enlarge front door, all new plumbing fixtures, new LED lighting throughout, new skylight in new mudroom, all new finishes, replace wood burning fireplace with gas fireplace, all new appliances, siding will be painted and new brick coursing installed in select wall infills - 3,734 sq ft total I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 01/20/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Interior Remodel Date: Tuesday, November 10, 2020 3:34:31 PM Residential Interior Remodel This application is exclusively for Residential Interior Remodels and other scopes of work which do not have a specific form already available. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 3980 Garrison St. Wheat Ridge, CO 80033 Property Owner Name Trent Scott Peaker Property Owner Phone 720-301-8132 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email tp@megastarfinancial.com Address Attach City of Wheat Electronic Payment Form 11.10.20.odf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" APPLICANT INFORMATION Applicant Name Lauren C Watkins What is your role in the Architect project? Contact Phone Number 720-295-7386 (enter WITH dashes, eg 303-123-4567) Contact Email Address Iwatkins@knottyiron.com for Plan Review Comments Retype Contractor Iwatkins@knottyiron.com Email Address DESCRIPTION OF WORK Detailed Scope of The scope of work includes a full interior remodel on the Work - In the space basement and first floor levels. Interior partitions and doors will below (not as an be removed and replaced within a new layout for both floors. attachment), Provide a Ceilings on both floors are to be removed and replaced with new. detailed description of Existing windows will be replaced with new throughout, and in work including certain locations, window sizing will change and/or be replaced mechanical, electrical, with new exterior doors. Exterior doors will be replaced plumbing work throughout (except at the garage), and the front door will be relocated and enlarged. Interior plumbing fixtures will be occurring, removed, relocated and replaced with new. Existing light fixtures adding/removing walls, will be replaced with new LED lighting throughout. The existing etc roof and foundation walls are to remain as existing, except for a new skylight above the proposed mudroom. All existing finishes will be removed and replaced with new. The existing wood burning fireplace will be removed and replaced with a new gas fireplace. All existing appliances are to be removed and replaced with new high efficiency models. Existing exterior wood siding will be painted and new brick coursing will be installed in select wall infill locations. I, the applicant, I have entered a detailed scope of work. understand my application will be rejected if I do not include a Detailed Scope of Work. Location of Work The location of workwill encompass the entire Basement and First Floor Square Footage Area 3,734 SQ. FT. of Work Being Performed I' bestos Report c1•%t:D1�T51ii6�•tii.��GF7iZ�3 •�.�fil Amended 11 10 20 Ddf Upload letter size Asbestos Letter 11.10.20.pd documents here Construction PlansisF.i•ZeF1iiC3.7ii.9i7Ciai:ZC:CaTS�iiilf[.Y7iifiZi[•I�I•l.T.f scanned larger Project Value (contract $528,200 value or cost of ALL $528,000 Valuation materials and labor) OK SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Permit I attest that everything stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Yes Yes Yes Lauren C. Watkins Yes Email not displaying correctly? View it in your browser. City of "� Wheatjdge COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 50190 64tfl5oft :� Permit#: Electrical Sub-Contractor Namej`ii; Tfi' A rIC IK Phone #: %Ai- Z358 State License #:tC_dI0to%�+ Master#: M.40085Z Wheat pidge License #: (required field) od.�.i 01- 1$- 202- 1 Signature of Autho ed Agedr Date Plumbing Sub -Contractor Company Name: Phone #: State License #: Master #: Wheat Ridge License #: (required field) Signature of Authorized Agent Date Mechanical Contractor Company Name: Phone: Wheat Ridge License #: (required field) Signature of Authorized Agent Date ,►4le • Clt Of =� N Wh6atPsid e g COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: General Electrical Sub -Contractor Company Name: State License Wheat Ridge License Signature of Authorized Agent Plumbing Sub -Contractor Company Name: State License Permit #: Phone #: Master #: (required field) Date Phone #: Master Wheat Ridge License #: (required field) Signature of Authorized Agent Mechanical Contractor Date Company Name: RO Heating Inc. Phone: 303.934.4273 Wheat Ridge License #: ? ZJ i e2 l F (required field) Signature5Uf Authorized Agent Date r City Of "� Wheat idge COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: Permit #: General Contractor: K aottw=0!?% Electrical Sub -Contractor Company Name: State License #: Phone #: Master #: Wheat Ridge License #: (required field) Signature of Authorized Agent Plumbing Sub -Contractor Date Phone g" CompanyName: 41 7vD � State License #: 1'Ci ©U 0 �l�-� Master #: 0' p 66 �Op6 SG � ` re Wheat Ridge License #: (required uired field)1 Signature of Author n Date Mechanical Contractor Company Name: Phone: Wheat Ridge License #: (required field) Signature of Authorized Agent Date IlPage Elevation Environmental Services 11 Elevation Environmental Services ♦s 13340 Harrison St Thornton CO 80241 Elevalion Environmental (833)536-8476 Asbesha 3980 Garrison St Wheat Ridge, CO 80033 Prepared For: Rarely Iron Trading Co General Contractor 2020) Prepared By: Elevation Environmental Services Asbestos 13340 Harrison St Contractor needed. Thornton, CO 80241 RS. CDPHE CERTIFICATE #'s: 24795, 25621 Date(s) ofInspection —November 3, 2020 / November 9, 2020 its of Wheat Ridge Building omi.mn 21Page Elevation Environmental Services Table of Contents 1.0 Asbestos Regulations................................................................................................................................. 3 2.0 Introduction.................................................................................................................................................. 4 3.0 Homogenous Area...................................................................................................................................... 4 4.0 Asbestos Containing Material................................................................................................................... 4 5.0 Non -Asbestos containing Material............................................................................................................ 5 6.0 Critical Areas................................................................................................................................................ 5 7.0 Asbestos Inspection Findings.................................................................................................................... 5 8.0 Asbestos Recommendations..................................................................................................................... 5 9.0 Sketch........................................................................................................................................................... 6 10.0 Pictures........................................................................................................................................................ 7-11 11.0 Asbestos Lab Reports................................................................................................................................. 12-19 12.0 Certifications................................................................................................................................................. 20-21 City of Wheat Ridge Building Division 31Page Elevation Environmental Services 1. Asbestos Regulations The EPA and the Colorado Department of Public Health and Environment (CDPHE) require all building materials with Asbestos Containing Materials (ACM) contain less than 1% asbestos via PLM analysis. OSHA requirements are more stringent It is required by law all friable and non -friable ACM be removed prior to renovation activities that may disturb verifiable and assumed ACM. Furthermore, all friable ACM must be removed prior to demolition. Point counting is required for bulk samples where the asbestos content is less than 10%. Federal and State agencies define ACM as those containing more than 1%. National Emission Standards for Hazardous Air Pollutants (NESHAP) requires materials with ACM less than 10% be point counted or be "assumed" ACM. If point counting is done, the result supersedes the non -point counted PLM result. Homogeneous Material Classifications • A preliminary walk through of the buildings was conducted to determine areas of materials which were visually similar in color, texture, general appearance, and which appeared to have been installed at the same time. Such materials have been termed "homogeneous materials" by the EPA. During this walk through, the approximate locations of these homogeneous materials were noted. • Following the EPA inspection protocol, each identified suspect homogeneous material was placed in one of the following EPA classifications: Surfacing Materials — Sprayed or troweled on surfaces (walls, ceilings, structural members) for acoustical, decorative, or fireproofing purposes. This includes plaster and fireproofing insulation. Miscellaneous Materials — Other non -friable products and materials such as floor tile and ceiling tile. Thermal System Insulation —Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold -water systems and heating, ventilation, and air conditioning (VAC.) systems. This includes pipe lagging, pipe wrap, block, batt, blanket insulation, cements, muds, gaskets and ropes. (These materials were not sampled as part of the survey.) Friability Classifications Friable and non -friable ACM's are defined as follows: • Friable asbestos -containing material: any material containing more than 1% asbestos, determined using PLM analysis, that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. • Category I nonfriable asbestos -containing material: asbestos -containing resilient floor covering, mastic or asphalt roofing product containing more than 1% asbestos as determined using PLM. • Category II nonfriable asbestos -containing material: any material, excluding Category I non -friable ACM, containing more than 1% asbestos as determined using PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. • Regulated asbestos -containing material (RACM): (1) friable ACM, (2) Category I nonfriable ACM That has become friable, (3) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (4) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the materials in the course of demolition or renovation operations. Sampling and Laboratory Analysis Bulk samples were collected by using various sampling tools (cutting tools, knives and chisels) to cut away or scrape portions of suspect building materials into zip -sealed plastic bags or sampling tubes. Samples areas were chosen by using a 3x3 sampling grid and a random number generator on the inspector's phone. The individual samples were labeled by material type and location. Samples were analyzed by Reservoirs Environmental Laboratory located in Denver, CO. The laboratory maintains accreditations through the American Industrial Hygiene Association (AIHA), and National Voluntary Laboratory Accreditation Program (NVLAP). The analysis performed was EPA Method 600/R-93/116. City of Wheat Ridge Building Division 41Page 2. Introduction Elevation Environmental Services On November 3, 2020 — Elevation Environmental Services performed a full scope interior inspection of the structure at 3980 Garrison St, Wheat Ridge CO. The interior is getting a full remodel and all interior suspect materials need to be tested for asbestos. On November 10, 2020 — Elevation Environmental Services returned to the site to do an exterior inspection. Client informed EES that some exterior components will be impacted during the renovation. All amended items will be in bold. 3. Homo enous Area Table HA Ref # Sample Name Size Sqft (unless noted) Sketch Ref # Samples Collected Locations Friability Condition G= Good D=Damaged SD= Severely Damaged Material Type 1 ACTO1 156 22-23 2 Downstairs kitchen F G MISC 2 CKO1 40 31-32 2 Bathrooms and kitchens NF G MISC 3 FTO1 140 24-25 2 Basement closets / under staris NF G MISC 4 FT02 430 26-27 2 Basement living room NF G MISC 5 GTO1 165 16-17 2 Bathroom floors F G MISC 6 TAO 50 14-15 2 Master shower walls F G MISC 7 TA02 100 18-19 2 Guest bath and basement bath showers F G MISC 8 TSO1 1200 1-5 5 Living room and hall F G SURF 9 TS02 858 6-8 3 Dining room and kitchen F G SURF 10 TS03 1600 9-13 5 Bedrooms and bathrooms F G SURF 11 TS04 900 28-30 3 Basement bath F G SURF 12 WGO1 80 20-21 2 All windows F G MISC 13 ECK01 300 2 Caulk around doors and windows exterior NF G MISC 14 GT01 2000 2 Mortar in brick NF G MISC 15 RM01 1 1400 1 12 Roof Material NF G MISC 4. Sample Results — Asbestos Containing City of Wheat Ridge Building Division ACM Sample ID Sketch Ref # Description ACM Description Content Ref 3980-FT02-01 4 26-27 Spotted 12x12 vinyl floor file w/ Beige/multi-colored file 15 black mastic 3980-TS01-01 S 1-5 Spanish Knife Texture Cream Compound 3 3980-TS02-01 9 6-8 Light orange peel Beige Compound 3 3980-TS03-01 10 9-13 Medium orange peel Beige compound 3 3980-TSO4-01 11 25-30 Heavy orange peel Beige compound 3 City of Wheat Ridge Building Division 51Page 5. Elevation Environmental Services PLM Determined Non -Asbestos Containing Material Sample ID HA Sketch Ref # Description 3980-ACT01-01 1 22 Acoustic ceiling tile with pinholes and directional fishers 3980-ACT01-02 1 23 Acoustic ceiling tile with pinholes and directional fishers 3980-CKO1-01 2 31 White caulk 3980-CKO1-02 2 32 White caulk 3980-FTO1-01 3 24 Parkay look floor colorless adhesive 3980-FTO1-02 3 25 Parkay look floor colorless adhesive 3980-GTOl-01 5 16 Pink grout 3980-GTOl-02 5 17 Pink grout 3980-TA01-01 6 14 Yellow adhesive 3980-TA01-02 6 15 Yellow adhesive 3980-TA02-01 7 18 Off white grout adhesive 3980-TA02-02 7 19 Off white grout adhesive 3980-WGO1-01 12 20 Gray window glazing 3980-WGO1-02 12 21 Gray window glazing 3980-ECKOI-01 13 35 White caulk around exterior windows and doors 3980-ECKOI-02 13 36 White caulk around exterior windows and doors 3980-GTOI-01 14 33 Gray mortar between exterior red brick 3980-GTO1-02 14 34 Gray mortar between exterior red brick 3980-RMOI-01 15 37 Black shingle with black felt 3980-RMO1-02 15 38 Black shingle with black felt 6. Critical Areas Roof — Inspected Attic — paper backer fiberglass insulation Crawlspace — Not applicable Flooring- Sampled 7. Asbestos Inspection findings Elevation Environmental Services (EES) performed afull interior asbestos inspection. The structure is scheduled for a full gut and needed every area on the interior tested. EES found 12 Homogenous areas during the inspection. The exterior inspection found no asbestos containing material. The exterior is brick and wood. The roof was sampled for an additional skylight install. Samples were gathered according to AHERA standards which means a minimum of 3 samples for Surfacing Material and a minimum of 2 samples for Miscellaneous Material. Samples were delivered to Reservoirs Environmental for analysis. Analysis did find asbestos containing material in the samples collected from the walls, ceilings, and basement flooring under the carpet. No exterior samples were found to contain asbestos. 8. Asbestos Recommendations Elevation Environmental Services did rind asbestos containing material during the inspection. The walls and ceilings throughout the structure and floor tile under carpet in the basement are all asbestos containing. These areas will need to be abated by a licensed and certified Colorado asbestos abatement contractor if disturbance is planned. These areas will also need an Air Clearance at the end to make sure the are is clear for reentry after abatement. City of Wheat Ridge Building Division filPage Elevation Environmental Services 9. Sketch City of Wheat Ridge Building Division Elevation Environmental Services 7347=0 -TTO1/-ep% 3-FFo -7a-o, i Cityof Wheat Riaee s Building omi.mn UlPage Elevation Environmental Services 11. Asbestus Laboratory Reports ties, I ass w Now lessor Ni ft. Missai sectors, im No I IN City of Wheat Ridge aui I ng Division ��. ne"'c-seennyr.wu T...d assets s ties, I ass w Now lessor Ni ft. Missai sectors, im No I IN City of Wheat Ridge aui I ng Division City of Wheat Ridge aui I ng Division llll"age Elevation Environmental Services JiffilinhNseed, Rill ki I al ft. Mini nviw. signs w"'c-ssennpteun 'Ins, y Mogen PM ki I al ft. Mini munixri�.ammwm'nwNN vNmmwyhe. du wlnruuguu�naic City of Wheat Ridge Building Division 141Page Elevation Environmental Services JEIJMN~ Marano' uwt"sw�mo MMM) Wind M w �'c-wennptun '�r.., i�•a. E >f++ ,Mm wnvbN 4M..Wa. uwwlnrur.wmen.iv PAY of Wheat Ridge Bu ml ng Divi:ion It 11 RD w I >f++ ,Mm wnvbN 4M..Wa. uwwlnrur.wmen.iv PAY of Wheat Ridge Bu ml ng Divi:ion ]511'age Elevation Environmental Services gadaeousi III loo avivu m is osot�ll ToIgusid xamv��s-seN'speo wi A As III MINViddislissisdi mxww�mmnw>wbium.m.nn.rt. uevq a sw,. "in.nv mw.`o. an City of Wheat Ridge Building Division MIPage Elevation Environmental Services TRea:ervairs EnNmnmen[al, Inc. xcs.wn x. 477474 dry of Wheat Ridge Bu lml ng Divi:ion muuwwarw«kn '7 .a... �� ew vuwm t ! ,. ,.a.A..,a...—.... n«..m.nm.ow Is MM �tlRPOl�1 l lei€S` ilf {'Il ➢, a f �E l€ u....._.+ s.4 IT -it dry of Wheat Ridge Bu lml ng Divi:ion 171Page Elevation Environmental Services Cts of Wheat Ridge Building Division flefe mEnN.mmen I Inc.at Till 11 iS SIS' i °i t7� III mea. ma. s,mmm.. ses,.ewu......+.ill �! i� e m 1—, Cts of Wheat Ridge Building Division BIPage Elevation Environmental Services RESERVOIRS ENVIRIGHWENTAL INC. ME Ns NI ,11iii IN, L ON Pines Miss, I p 0 IN, wMi ell wonDMINMessesins, r1 .c-axxxner. `.mm�M" NinxiBases. Ne &M. sound Mosists, 11 211 City of Wheat Ridge Building Division IN, L NI Nas ell Mi I Now rel NinxiBases. 11 A MIMI Ni AIM NM in I in Iy V Is, 0 100 City of Wheat Ridge Building Division IDlPage Elevation Environmental Services T fleservans Envimnmen[al, Inn Be rnss City of Wheat Ridge Building Division ASIA ... ASS isississer's, roless, ii A. IIf1 .`. o. Secret_ ASSAMS,AAAAAASAAAAMAr ASIA A. ij €ft li�i'�.. Amo 9 if, 1f6, ]f;s�l I _ MIAMI m _ .ASIAM, _,:: City of Wheat Ridge Building Division ASIA City of Wheat Ridge Building Division Elevation Environmental Services Wheat Flop Building Division ( ! !- 2 §,seac / »rE \ 2s E/C ( ]: § � 4 Wheat Flop Building Division / \ Wheat Flop Building Division 3980 GARRISON ST WHEAT RIDGE, CO 80033 Owner Trent Peaker 1710 S. Newport Way Denver, CO 80224 720.301.8132 tPO-megastarfinancial.com {.�� { y.k_ z. 1 ti'r �}• �1 � • qtr r � .•rti 1 �'���� M-..6 ~� - -, � • _ - Wit- .-__- -• - • 1 w:: J STI ii -Jewr - - i F F Architect & Contractor Knotty Iron Trading Co 2420 W. Main St Unit 100 Littleton, CO 80120 720.617.9658 www.knottyiron.com 4 K� I rte— � — � - • - T�'•�• '�- •'1 Ly la 1.• 1 ' I I - PERMIT SET 11.10.2020 General Architectural Structural ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Projects are Subject to Field Inspections All work shall comply with: • 2018 International Residential Code • 2020 National Electrical Code • State of Colorado Plumbing Code 1 City Of /f W heat �idge COMMUNITY UEVEIUI MENT APPROVED Reviewed for Code Comliance Randy Slusser 12/14/2020 Plans Examiner Date Validkv of oennh: The issuooce o f o pomlt or Wprovirl of plans spec4kattone and computations shah rwt be a permit lar, or on approval of, any violation to any of tAe provlslom of the building code or of oj► Qy ordiaxwes. Permits premmng to give outha lty to vidke or cancel the pravislau of the iWldV codes or other ordtnooM of the City shoo not be roltd Sheet Number Sheet Name IH W W a GENERAL G0.00 COVER SHEET ■ G0.02 GENERAL NOTES & ABBREVIATIONS ■ DEMOLITION D1.00 DEMO PLAN BASEMENT ■ D1.01 DEMO PLAN FIRST FLOOR ■ ARCHITECTURAL A1.00 BASEMENT_ PROPOSED ■ A1.01 FIRST FLOOR PROPOSED ■ A2.01 REFLECTED CEILING PLANS EXISTING ■ A2.02 REFLECTED CEILING PLAN PROPOSED ■ A3.01 SOUTH ELEVATION ■ A3.02 NORTH ELEVATION ■ A3.03 EAST ELEVATION ■ EC0.01 ENERGY CODE COMPLIANCE ■ STRUCTURAL S1.00 STRUCTURAL DRAWINGS FIRST FLOOR ■ S1.01 STRUCTURAL DRAWINGS BASEMENT 0 0 O CO3 MMW■4 r PO0L/C :,O?tiSGy\N C) • V Ir e.aa•. ..saa Z19C H 1"_„r,o� FM LIJ � � N FM O N � O LIJ r a Uj V Z LU M Cn FM Q O O LU Cj) 0(M) ce OW ce Cf) LU a �a LU LU a. M ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS MATERIAL LEGEND & AND @ AT ACT ACCOUSTCAL CEILING TLE AD AREA DRAIN ADJ ADJACENT ALL ABOVE FINISHED FLOOR AFS ACCESS FLOORING SYSTEM AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED AP ACCESS PANEL APC ACOUSTICAL PANEL CELI NG ARCH ARCHITECTURAL ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS ASPH ASPHALT AT ACOUSTICAL TREATMENT AWC ACOUSTICAL WOOD CEILING B BASE BA BATH ACCESSORY BIT BITUMINOUS BL BORROWED LIGHT BLDG BUILDING BLKG BLOCKING BM BEAM BO BOTTOM OF BOT BOTTOM BE BRICK BEG BEARING BTWN BETWEEN CAN CABLE TELEVISION CB CEMENTBOARD CCD CONSTRUCTION CHANGE DIRECTIVE CCN CLOSED CIRCUIT TELEVISION CG CORNER GUARD OF CAST N PLACE CJ CONRTOL JOINT CL CENTERLINE CLG CEILING CLR CLEAR CMU CLAY MASONRY UNIT CO CHANGE ORDER COL COLUMN GONG CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTE CONTRACT(OR) CORR CORRIDOR CPP CARPET PAG CPT CARPET CS CONCRETE STAINING CT CERAMIC TILE CW CASEWORK CWS CURTAIN WALL SYSTEM DBL DOUBLE DEPT DEPARTMENT GF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOM DS DOWNSPOUT DWG DRAWING (E) EXISTING EA EACH EF EXHAUST FAN EJ EXPANSION JOINT ELEC ELECTRIC(AD ELEV ELEVATION ENT ENTRANCE SYSTEMS EP EPDXY PAINT EQ EQUAL EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EWS EXTERIOR WALL SYSTEM EXP EXPOSED EXT EXTERIOR FACE FIRE ALARM CONTROL PANEL FAP FLUID APPLIED FLOORING FBO FURNISHED BY OWNER FCU FAN COIL UNIT FD FLOOR DRAIN FRY FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FH FIRE HYDRANT FHC FIRE HOSE CABINET FIAT FIXTURE FO FACE OF FRT FIBER REINFORCED LAMINATED FRP FIBERGLASS REINFORCED PANEL FRT FIRE RETARDANT TREATED FT FEET FTG FOOTING GA GAUGE GALA GLAVANIZED GB GRABBAR GC GENERAL CONTRACTOR GM GYPSUM WALLBOARD GYP GYPSUM HCAP HANDICAP(PED) HDWR, HARDWARE HW HM HOLLOW METAL HORIZ HORIZONTAL HE HIGH POINT HE HOUR HT HEIGHT HVAC HEATING, VENTILATION AND AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE IF INSIDE DIAMETER IIC IMPACT ISOLATION CLASS INFO INFORMATION INSUL INSULATION or INSULATED INT INTERIOR JAN JANITOR JT JOINT LAB LABORATORY LAM LAMINATE LAV LAVATORY LF LINEAR FEET LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LMC LINEAR METAL CEILING LP LOW POINT MAX MAXIMUM MECH MECHANICAL MEP MECHANICAL, ELECTRICALAND PLUMBING M FEE MEZZANINE MF M ASON RY FLOOR NG MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MR MIRROR MTD MOUNT(ED) MIT MFTAL MULL MULLION NA NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOTTO SCALE OA OUTSIDE AIR OC ON CENTER 00 OUTSIDE DIAMETER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED OPNG OPENING OPP OPPOSITE ORD OVERFLOW ROOF DRAIN PC PRECAST CONCRETE PL PROPERTYLINE PLAM PLASTIC LAMINATE PLED PLUMBING PLWD PLYWOOD PR PAIR PREFAB PREFABRICATED HALT PARTIAL HEIGHT PROD PROJECT PSP POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PAINT PTD PAINTED PTR PAPER TOWEL RECEPTACLE OF QUARTZ FLOORING QS QUARTZ SURFACING QT QUARRY TILE OZ QUARTZ R RISER RB RESILIENT BASE RCP REFLECTED CEILING PLAN RD ROOF GRAIN RE REFER TO or REFERENCE REC RECESS(ED) REFR REFRIGERATOR or REFRIGERATED RENF REINFORCED READ REQUIRED REV REVISE, REVISED or REVISION RF RESILIENT FLOORING RFG ROOFING RO ROUGH OPENING RR RESTROOM SCHER SCHEDULE SECT SECTION SF SQUARE FEET, STONE FACING SHTG SHEATHING SIM SIMILAR SOX SLAB ON GRADE SPEC SPECIFICATION(S) SQ SQUARE ss STAINLESS STEEL ST STONE STC SOUND TRANSMISSION CLASS STD STANDARD STG STORAGE STY STEEL STN STONE SLAB STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED) SYS SYSTEM T TREAD, TLE T&G TONGUE AND GROOVE TA TOILET ACCESSORY TEL TELEPHONE THE THRESHOLD TO TOP OF TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TOP OF WALL TR TRIM TYP TYPICAL TZ TERRAZZO UL UNDERWRITER'S LABORATORY UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE UR URINAL VB VINYL BASE VCT VI NYL COMPOSITI ON TILE VERT VERTICAL VEST VESTIBULE VTR VENT THRU ROOF vw WITH vwo WITHOUT WC WATER CLOSET, WALL COVERING WD WOOD WF WIDE FLANGE, WOOD FLOORING WOM WALK OFF MAT WE WORKING POINT WS WINDOW SHADES WT WALL TLE LEVEL.01 ELEVATION MARK GRID UNE AND IDENTIFICATION 100.0" XD AD Y SPOTELEVATION MARK 0 c NORTH DIRECTION MARK PLAN TRUE ROOM NAME ROOM NAME TAG 181 EXTERIOR ELEVATION MARK X C SHEET NUMBER 2814A DOORNUMBERTAG A3 o1 XINTERIOR ELEVATION MARK X Afi 01 X SHEET NUMBER X SECTION MARK SIM 01 SHEET NUMBER CALLOUTMARK IM 1m SHEET NUMBER DRAWING TITLE 4 View Name \\\\1/8" = V-0" SCALE DRAWING NUMBER 0 WINDOWTAG C� REVISION TAG 18,8• CEILING HEIGHT TAG C88 CASEWORK TAG wALL1) EXTERIORWALLTAG 32-A INTERIOR PARTITION a TAG LA LOUVER TAG HIDDEN LINE (ABOVE, BELOW ORBEYC ® PROPERTY LINE MATCH LINE SCOPE OF WORK LINE GENERAL DEMOLITION NOTES GENERAL PLAN NOTES GENERAL ELECTRICAL NOTES GENERAL RCP NOTES VICINITY MAP 1. GASHED LINES ON DEMOLITION PLAN INDICATES EXISTING MATERIALS TO BE REMOVED. EQUIPMENT TO BE REUSED SHALL BE STORED AND PROTECTED FROM DAMAGE DURING CONSTRUCTION. ANY DAMAGE RESULTING FROM CONSTRUCTION WILL BE REPAIRED TO ITS ORIGINAL STATE. 2. THE FOLLOWING DEFINITIONS APPLY FOR THIS PROJECT. DEMOLISH'. TEAR DOWN COMPLETELY, REMOVE FROM SITE REMOVE DISMANTLE, PROTECTAND STORE FOR COORDINATION WITH PROPERTY MANAGEMENT OR OWNER 3. CONSTRUCTION IN AREAS TO BE RENOVATED SHALL BE CAREFULLY COORDINATED WITH THE OWNER, ARCHITECTS PRIOR TO CONSTRUCTION. EXISTING EQUIPMENT WILL BE RELOCATED OR STORED AS PER OWNER'S DIRECTION. EQUIPMENTAND FURNISHINGS TO BE STORED SHALL BE PROTECTED FROM DAMAGE AND VANDALISM IN LOCATIONS ACCEPTABLE TO THE OWNER 4. DEMOLITION EXPOSING THE INTERIOR OF THE BUILDING TO THE OUTSIDE ELEMENTS OR TO THE PUBLIC SHALL BE PROPERLY SEALED AND PROTECTED TO ELIMINATE DAMAGE FROM VANDALISM OR WEATHER DURING CONSTRUCTION. 5. CONTRACTOR SHALL INCLUDE AND PERFORM ALL DEMOLITION WORK REQUIRED TO ACCOMMODATE NEW WORK UNDER CONTRACT. 8. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO DEMOLITION WORK. PROBLEM S OR GI SO REPAY CI ES IN THE PLANS SHALL BE REPORTED AT ONCE TO TH E ARCHITECTS AN ALL WORK INVOLVED AT SAID QUESTION EG AREA SHALL BE HALTED UNTIL ARCHITECT GIVES NOTICE TO PROCEED. ]. UNLESS DETAILED OR SCHEDULED OTHERWISE, ALL AREAS AFFECTED BY REMQUIT ON WORK SHALL BE PATCHED ANo/OR REPAIRED TO MATCH EXISTING ADJACENT SURFACES AND FINISHED. REPAIR SHALL MATCH EXISTING ADJACENT SURFACES. 8. REMOVE ALL EXISTING DOORS&FRAMES SHOWN AS DEMOLISHED OR SALVAGE FOR RELOCATION IN NEW PLAN. 8. REPAIR WALL DAMAGED BY DEMOLITION TO PROVIDE SMOOTH SURFACE, WITH PATCHES DRESSED FLUSH, SMOOTH AND READY TO RECEIVE FINISH MATERIAL IF GYPSUM BOARD BEHIND FINISH SURFACE IS UNSUITABLE FOR RECONSTRUCTION REPLACE WITH NEW GYPSUM BOARD. 18. REPAIR SOFFIT CEILING FINISHES LEFT VOID OR DAMAGED BY DEMOLITION WORK TO MATCH EXISTING ADJACENT FI PUSHES. RE REFLECTED CEILING PLANS FOR EXTENT OF NEW CEILING WORK TO BE COMPLETED. 11. COORDINATE STRUCTURAL MECHANICAL ELECTRICAL, AND PLUMBING REMQUIT ON AS INDICATED IN DRAWINGS WHEN PRESENT EXISTING M ILLWORK, LIGHTING AN 0 PLUM BING FIXTURES NOT TO BE REU SED ARE TO BE REMOVED. 12. WH ERE PLU M BI N G FIXTU RES ARE REM OVER, OI SCON N ECT, REM OV E OR CAP UTILITY SERVICES AS INDICATED IN THE CONTRACT DOCUMENTS. RE PLUMBING I3. PATCH ALL FLOOR AND WALL PENETRATION WITHIN PROJECT AREA TO MAINTAIN FIRE RATING. 14. GENERAL CONTRACTOR TO PROPERLY DISPOSE OF DEMO ITEMS UNLESS OTHERWISE NOTED TO RETURN TO OWNER. 15. ITEMS TO BE SALVAGED FOR REUSE INCLUDE, BUT ARE NOT LIMITED TO'. HVAC BOOTS, RETURN AIR GRILLES, HVAC CONTROL DEVICES, HVAC DUCT WORK, LIGHT FIXTURES, WIRING DEVICES, DOORS, DOORFRAMES HARDWARE, PIPING, & SUSPENSION MEMBERS. 18. ITEMS TO BE SALVAGED SHALL BE CAREFULLY REMOVED INA MANNER TO ENSURE MINIMUM DAMAGE. ALL ITEMS NOT USED IN BUILD OUT SHALL BE REMOVED FROM SITE AT ENO OF CONSTRUCTION. 1. REFER TO SHEET AB 01 FOR ARCHITECTURAL SYMBOLS 2. GROUND FLOOR ELEVATION IS 188'-8" (XXXXXX) 3. UNLESS OTHERWISE NOTED IN SECTION OR IN PLAN ALL INTERIOR PARTITION TYPES ARE 3 1/2" WOOD STUDS W/ TWO LAYERS 5/8" GYPSUM 4. EXTERIOR DIMENSIONAL REFERENCES REFER TO FACE OF STONE OR FACE OF GLASS UNLESS NOTED OTHERWISE 5. INTERIOR DIMENSIONAL REFERENCES REFER TO FINISHED FACE OF PARTITION, UNLESS NOTED OTHERWISE 8. ALL DOORS TO BEOFFSET 6 TYPICAL, U N 0. ]. SMOKE ALARM S SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS • IN EACH SLEEPING ROOM. • OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. • ON EACH ADDITIONAL STORY OF THE DWELLING INCLUDING BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WTHOUTAN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. R314 2 8. APPROVED CARBON M ONOXIDE ALARM (S) SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS IN DWELLING UNITS WITHIN WHICH FUELFIREDAPPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. R3152 8. PROVIREA NONABSORBENT SUPLACE AND WATER-RESISTANT BACKING IN TUBS AND SHOWERS TO A MINIMUM HEIGHT OF B'-8". BACKING FOR ADHESIVE APPLICATION TO BE CEM ENT BOARD IF CERAM IC TILE OR OTHER REQUIRED NONABSORBENT FINISH MATERIAL IS USED. R782 3 & R7824 10. WHERE FLOO WCELING OR ROOF/CEILING FRAM IG EXCEEDS 18" ON CENTER ,v" SAG -RESI STAN OR Q, G RYWA LL IS REQU I REG. DRYWALL ORIENTATION IS TO BE PERP EN OI CU LAR TO THE FRAMING MEMBERS. TABLE R]8235 11 ALLFLOOR/CEILING ASSEMBLIES SHALL BE PROVIDED WITH A 1/2 INCH GYPSUM WALLBOARD MEMBRANE, 5/8 INCH WOOD STRUCTURAL PANEL MEMBRANE, OR EQUIVALENT ON THE UNDERSIDE OF THE FLOOR FRAMING MEMBER (ALLCEILINGS, STORAGE MECH ROOMS, ETC) 12. TIES SUPPORTING ANCHORED V EN PER MUST BE PROVIDED TO SUPPORT NO MORETHAN 287 SF OF VENEER PERTEAND SPACED NO MORETHAN 24" ON CENTER VERTICALLY AND 32" HORIZONTALLY. R783 8 13. SOLID BLOCKING OR BRACING IS REQUIRED BETWEEN THE ROOF TRUSSES AND RAFTERS AT ALL POINTS OF BEARING. R8828&R802.18.3 14. ROOF RAFTERS AND TRUSSES MUST BE ATTACHED TO SUPPORTING WALL ASSEMBLIES BY CONNECTIONS CAPABLE OF PROVIDING THE RESISTANCE REQUIRED IN TABLE R88211. 1. ALL POWER AND SIGNAL FIXTURES ARE DIMENSIONED TO CENTER OF FIXTURE UNLESS NOTED OTHERWISE. 2. ALL POWER ANG DATA RECEPTACLES TO BE M OU NTEG 18" AFF. UNLESS NOTED OTHERWISE 3. ALL ELECTRICAL RECEPTACLES LOCATED IN BATH ROOMS, GARAGES, OUTDOORS, CRAWL SPACES, UNFINISHED BASEM ENT AREAS, KITCHENS SERVING THE COUNTERTOPS, AN WITHIN 8OF THE OUTSIDE EDGE OF WET BAR SINKS MUST BE GROUND FAULT CIRCUIT INTERRUPTER PROTECTED. GFCI PROTECTION IS ALSO REQUIRED FOR ALL ELECTRICAL EQUIPM ENT ASSOCIATED WITH SPATYPEBATHTUBS OR HOT TUBS. [ARTICLES 2180(A), 68842 AND 68843 NEC 4. ELECTRICAL RECEPTACLES MUST BE PROVIDED IN ALL HABITABLE ROOMS FOR EACH WALL SPACE 24" OR MORE IN WIDTH SO THAT NO POINT ALONG THE FLOOR LINE IS MORE THAN fi' FROM A RECEPTACLE. ARTICLE 21052(A) NEC 5. A SWITCHCONTROLLEDLIGHTING OUTLET IS REQUIRED FOR EACH HABITABLE ROOM. EXCEPT FOR KITCHENS AND BATHROOMS, A SWITCH - CONTROLLED RECEPTACLE IS PERMITTED IN LIEU OF ALIGHTING OUTLET. SWITCHCONTROLLEDLIGHTING OUTLETS ARE ALSO REQUIRED IN HALLWAYS, STAIRWAYS. UTILITY ROOMS AND BASEMENTS USED FOR STORAGE OR CONTAINING EQUIPMENT ALSO REQUIRED SWITCHCONTROLLEDLIGHTING OUTLETS. [ARTICLE 218 78(A) NEC] GENERAL PLUMBING NOTES 1. THE COMBINED DISCHARGE FROM A DISHWASHER ANDA ONE ORTWO COMPARTMENT SINK, WITH OR WTHOUT A FOOD WASTE DISPOSER, SHALLBE SERVED FLA TRAP OF JOYLESS THAN 1 1/2 INCHES IN OUTSIDE DIAMETER. THE DISHWASHER DISCHARGE PIPE OR TUBING SHALL RISE TO THE UNDERSIDE OF THE COUNTER AND BE FASTENED OR OTHERWISE HELD IN THAT POSITION BEFORE CONNECTING TO THE HEAD OF THE FOOD WASTE DISPOSER OR TO AME FITTING IN THE SINK TAILPIECE. P27171 2&3 2. GAS SHUTOFF VALVES SHALL BE LOCATED THE SAME ROOM/AREA WITHIN 8 FEET OF THE APPLIANCE TO PROVIDE ACCESS FOR OPERATION AND SHALL BE INSTALLED TO BE PROTECTED FROM DAMAGE. THE SHUTOFF VALVE SHALL BE INSTALLED UPSTREAM OF THE UNION, CONNECTOR OR QUICK DISCONNECT DEVICE T SERVES. SUCH SHUTOFF VALVES SHALL BE PROVIDED WITH ACCESS. APPLIANCE SHUTOFF VALVES LOCATED IN TH E FIREBOX OF A FIREPLACE SHALL BE INSTALLED IN ACCORDANCE WITH TH E APPLIAN CE MANUFACTURER'S INSTRUCTIONS. G24205 GENERAL MECHANICAL NOTES 1. CLOTHES DRYERS MUST BE PROVIDED WITH A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE EXTERIOR. IT M UST TERMINATE IN BACK DRAFT DAMPER AT LEAST 3' FROM ANY OPENING INTO THE BUILDING. THE SIZE OF THE DUCT IS TO BE DETERMINED BY THE DRYER MANUFACTURER, TYPICALLY, A4 DUCT WOULD BE ACCEPTABLE. THE MAXIMUM COMBINED LENGTH MAY NOT EXCEED35' INLENGTH. M15824, TABLEM15024. 2. EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF 488 CUBIC FEET PER MINUTE SHALL BE PROVIDED WITH MAKEUP AIR ALA RATE APPROXIMATELY EQUALTO THE EXHAUST AIR RATE. SUCH MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH A MEANS OF CLOSURE AND SHALL BE AUTOMATICALLY CONTROLLED TO START AN 0 OPERATE SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. IRC M 15830 1. ALL DIMENSIONS ARE TO CENTER LINE OF LIGHT FIXTURE UNLESS NOTED OTHERWISE 2. ALL RECESSED LIGHTING SHALL BE CENTERED IN CORRIDORS AND ALIGNED AS SHOWN UNLESS NOTED OTHERWISE 3. SEE ELECTRICAL DRAW NGS FOR SPECIFIC FIXTURE TYPES AND OTHER INFORMATION 4. ALL FIXTURES AND DEVICES IN CEILING TLE SHALL BE CENTERED UNLESS NOTED OTHERWISE 5. CEILING ELEVATIONS ARE ABOVE FINISH FLOOR UNLESS NOTED OTHERWISE fi. WHEN "ALIGN" IS ON CEILING PLANS GYPSUM BOARD FASCIA ALIGNS WITH FINISH FACE OF WALL ]. ALL ROOMS WITH A SINGLE FIXTURE OR SINGLE RUN OF FIXTURES SHALL BE CENTERED IN ROOM FROM THE WIDEST PART UNO 971 ALUMINUM STEEL PLASTIC PLYWOOD EARTH ® SOLID SURFACE MATERIAL FINISHGRADEWOOD ® GRAVEL W U W 0 Lu W Q W am M M) W ~0 Z U � 0^, Lu U) LL LL (D< Q c) Lu 00 >_ M Emy H" 1`111111 e1. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 CONCRETE NO. BRICK DESCRIPTION CMU 11.10.2]20 STONE GYPSUM BO/PLASTER CEMENTITIOUS FIREPROOFING FIRESAFING RIGID INSULATION ® SEMI-RIGID INSULATION GENERAL DEMOLITION NOTES GENERAL PLAN NOTES GENERAL ELECTRICAL NOTES GENERAL RCP NOTES VICINITY MAP 1. GASHED LINES ON DEMOLITION PLAN INDICATES EXISTING MATERIALS TO BE REMOVED. EQUIPMENT TO BE REUSED SHALL BE STORED AND PROTECTED FROM DAMAGE DURING CONSTRUCTION. ANY DAMAGE RESULTING FROM CONSTRUCTION WILL BE REPAIRED TO ITS ORIGINAL STATE. 2. THE FOLLOWING DEFINITIONS APPLY FOR THIS PROJECT. DEMOLISH'. TEAR DOWN COMPLETELY, REMOVE FROM SITE REMOVE DISMANTLE, PROTECTAND STORE FOR COORDINATION WITH PROPERTY MANAGEMENT OR OWNER 3. CONSTRUCTION IN AREAS TO BE RENOVATED SHALL BE CAREFULLY COORDINATED WITH THE OWNER, ARCHITECTS PRIOR TO CONSTRUCTION. EXISTING EQUIPMENT WILL BE RELOCATED OR STORED AS PER OWNER'S DIRECTION. EQUIPMENTAND FURNISHINGS TO BE STORED SHALL BE PROTECTED FROM DAMAGE AND VANDALISM IN LOCATIONS ACCEPTABLE TO THE OWNER 4. DEMOLITION EXPOSING THE INTERIOR OF THE BUILDING TO THE OUTSIDE ELEMENTS OR TO THE PUBLIC SHALL BE PROPERLY SEALED AND PROTECTED TO ELIMINATE DAMAGE FROM VANDALISM OR WEATHER DURING CONSTRUCTION. 5. CONTRACTOR SHALL INCLUDE AND PERFORM ALL DEMOLITION WORK REQUIRED TO ACCOMMODATE NEW WORK UNDER CONTRACT. 8. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO DEMOLITION WORK. PROBLEM S OR GI SO REPAY CI ES IN THE PLANS SHALL BE REPORTED AT ONCE TO TH E ARCHITECTS AN ALL WORK INVOLVED AT SAID QUESTION EG AREA SHALL BE HALTED UNTIL ARCHITECT GIVES NOTICE TO PROCEED. ]. UNLESS DETAILED OR SCHEDULED OTHERWISE, ALL AREAS AFFECTED BY REMQUIT ON WORK SHALL BE PATCHED ANo/OR REPAIRED TO MATCH EXISTING ADJACENT SURFACES AND FINISHED. REPAIR SHALL MATCH EXISTING ADJACENT SURFACES. 8. REMOVE ALL EXISTING DOORS&FRAMES SHOWN AS DEMOLISHED OR SALVAGE FOR RELOCATION IN NEW PLAN. 8. REPAIR WALL DAMAGED BY DEMOLITION TO PROVIDE SMOOTH SURFACE, WITH PATCHES DRESSED FLUSH, SMOOTH AND READY TO RECEIVE FINISH MATERIAL IF GYPSUM BOARD BEHIND FINISH SURFACE IS UNSUITABLE FOR RECONSTRUCTION REPLACE WITH NEW GYPSUM BOARD. 18. REPAIR SOFFIT CEILING FINISHES LEFT VOID OR DAMAGED BY DEMOLITION WORK TO MATCH EXISTING ADJACENT FI PUSHES. RE REFLECTED CEILING PLANS FOR EXTENT OF NEW CEILING WORK TO BE COMPLETED. 11. COORDINATE STRUCTURAL MECHANICAL ELECTRICAL, AND PLUMBING REMQUIT ON AS INDICATED IN DRAWINGS WHEN PRESENT EXISTING M ILLWORK, LIGHTING AN 0 PLUM BING FIXTURES NOT TO BE REU SED ARE TO BE REMOVED. 12. WH ERE PLU M BI N G FIXTU RES ARE REM OVER, OI SCON N ECT, REM OV E OR CAP UTILITY SERVICES AS INDICATED IN THE CONTRACT DOCUMENTS. RE PLUMBING I3. PATCH ALL FLOOR AND WALL PENETRATION WITHIN PROJECT AREA TO MAINTAIN FIRE RATING. 14. GENERAL CONTRACTOR TO PROPERLY DISPOSE OF DEMO ITEMS UNLESS OTHERWISE NOTED TO RETURN TO OWNER. 15. ITEMS TO BE SALVAGED FOR REUSE INCLUDE, BUT ARE NOT LIMITED TO'. HVAC BOOTS, RETURN AIR GRILLES, HVAC CONTROL DEVICES, HVAC DUCT WORK, LIGHT FIXTURES, WIRING DEVICES, DOORS, DOORFRAMES HARDWARE, PIPING, & SUSPENSION MEMBERS. 18. ITEMS TO BE SALVAGED SHALL BE CAREFULLY REMOVED INA MANNER TO ENSURE MINIMUM DAMAGE. ALL ITEMS NOT USED IN BUILD OUT SHALL BE REMOVED FROM SITE AT ENO OF CONSTRUCTION. 1. REFER TO SHEET AB 01 FOR ARCHITECTURAL SYMBOLS 2. GROUND FLOOR ELEVATION IS 188'-8" (XXXXXX) 3. UNLESS OTHERWISE NOTED IN SECTION OR IN PLAN ALL INTERIOR PARTITION TYPES ARE 3 1/2" WOOD STUDS W/ TWO LAYERS 5/8" GYPSUM 4. EXTERIOR DIMENSIONAL REFERENCES REFER TO FACE OF STONE OR FACE OF GLASS UNLESS NOTED OTHERWISE 5. INTERIOR DIMENSIONAL REFERENCES REFER TO FINISHED FACE OF PARTITION, UNLESS NOTED OTHERWISE 8. ALL DOORS TO BEOFFSET 6 TYPICAL, U N 0. ]. SMOKE ALARM S SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS • IN EACH SLEEPING ROOM. • OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. • ON EACH ADDITIONAL STORY OF THE DWELLING INCLUDING BASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WTHOUTAN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. R314 2 8. APPROVED CARBON M ONOXIDE ALARM (S) SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS IN DWELLING UNITS WITHIN WHICH FUELFIREDAPPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. R3152 8. PROVIREA NONABSORBENT SUPLACE AND WATER-RESISTANT BACKING IN TUBS AND SHOWERS TO A MINIMUM HEIGHT OF B'-8". BACKING FOR ADHESIVE APPLICATION TO BE CEM ENT BOARD IF CERAM IC TILE OR OTHER REQUIRED NONABSORBENT FINISH MATERIAL IS USED. R782 3 & R7824 10. WHERE FLOO WCELING OR ROOF/CEILING FRAM IG EXCEEDS 18" ON CENTER ,v" SAG -RESI STAN OR Q, G RYWA LL IS REQU I REG. DRYWALL ORIENTATION IS TO BE PERP EN OI CU LAR TO THE FRAMING MEMBERS. TABLE R]8235 11 ALLFLOOR/CEILING ASSEMBLIES SHALL BE PROVIDED WITH A 1/2 INCH GYPSUM WALLBOARD MEMBRANE, 5/8 INCH WOOD STRUCTURAL PANEL MEMBRANE, OR EQUIVALENT ON THE UNDERSIDE OF THE FLOOR FRAMING MEMBER (ALLCEILINGS, STORAGE MECH ROOMS, ETC) 12. TIES SUPPORTING ANCHORED V EN PER MUST BE PROVIDED TO SUPPORT NO MORETHAN 287 SF OF VENEER PERTEAND SPACED NO MORETHAN 24" ON CENTER VERTICALLY AND 32" HORIZONTALLY. R783 8 13. SOLID BLOCKING OR BRACING IS REQUIRED BETWEEN THE ROOF TRUSSES AND RAFTERS AT ALL POINTS OF BEARING. R8828&R802.18.3 14. ROOF RAFTERS AND TRUSSES MUST BE ATTACHED TO SUPPORTING WALL ASSEMBLIES BY CONNECTIONS CAPABLE OF PROVIDING THE RESISTANCE REQUIRED IN TABLE R88211. 1. ALL POWER AND SIGNAL FIXTURES ARE DIMENSIONED TO CENTER OF FIXTURE UNLESS NOTED OTHERWISE. 2. ALL POWER ANG DATA RECEPTACLES TO BE M OU NTEG 18" AFF. UNLESS NOTED OTHERWISE 3. ALL ELECTRICAL RECEPTACLES LOCATED IN BATH ROOMS, GARAGES, OUTDOORS, CRAWL SPACES, UNFINISHED BASEM ENT AREAS, KITCHENS SERVING THE COUNTERTOPS, AN WITHIN 8OF THE OUTSIDE EDGE OF WET BAR SINKS MUST BE GROUND FAULT CIRCUIT INTERRUPTER PROTECTED. GFCI PROTECTION IS ALSO REQUIRED FOR ALL ELECTRICAL EQUIPM ENT ASSOCIATED WITH SPATYPEBATHTUBS OR HOT TUBS. [ARTICLES 2180(A), 68842 AND 68843 NEC 4. ELECTRICAL RECEPTACLES MUST BE PROVIDED IN ALL HABITABLE ROOMS FOR EACH WALL SPACE 24" OR MORE IN WIDTH SO THAT NO POINT ALONG THE FLOOR LINE IS MORE THAN fi' FROM A RECEPTACLE. ARTICLE 21052(A) NEC 5. A SWITCHCONTROLLEDLIGHTING OUTLET IS REQUIRED FOR EACH HABITABLE ROOM. EXCEPT FOR KITCHENS AND BATHROOMS, A SWITCH - CONTROLLED RECEPTACLE IS PERMITTED IN LIEU OF ALIGHTING OUTLET. SWITCHCONTROLLEDLIGHTING OUTLETS ARE ALSO REQUIRED IN HALLWAYS, STAIRWAYS. UTILITY ROOMS AND BASEMENTS USED FOR STORAGE OR CONTAINING EQUIPMENT ALSO REQUIRED SWITCHCONTROLLEDLIGHTING OUTLETS. [ARTICLE 218 78(A) NEC] GENERAL PLUMBING NOTES 1. THE COMBINED DISCHARGE FROM A DISHWASHER ANDA ONE ORTWO COMPARTMENT SINK, WITH OR WTHOUT A FOOD WASTE DISPOSER, SHALLBE SERVED FLA TRAP OF JOYLESS THAN 1 1/2 INCHES IN OUTSIDE DIAMETER. THE DISHWASHER DISCHARGE PIPE OR TUBING SHALL RISE TO THE UNDERSIDE OF THE COUNTER AND BE FASTENED OR OTHERWISE HELD IN THAT POSITION BEFORE CONNECTING TO THE HEAD OF THE FOOD WASTE DISPOSER OR TO AME FITTING IN THE SINK TAILPIECE. P27171 2&3 2. GAS SHUTOFF VALVES SHALL BE LOCATED THE SAME ROOM/AREA WITHIN 8 FEET OF THE APPLIANCE TO PROVIDE ACCESS FOR OPERATION AND SHALL BE INSTALLED TO BE PROTECTED FROM DAMAGE. THE SHUTOFF VALVE SHALL BE INSTALLED UPSTREAM OF THE UNION, CONNECTOR OR QUICK DISCONNECT DEVICE T SERVES. SUCH SHUTOFF VALVES SHALL BE PROVIDED WITH ACCESS. APPLIANCE SHUTOFF VALVES LOCATED IN TH E FIREBOX OF A FIREPLACE SHALL BE INSTALLED IN ACCORDANCE WITH TH E APPLIAN CE MANUFACTURER'S INSTRUCTIONS. G24205 GENERAL MECHANICAL NOTES 1. CLOTHES DRYERS MUST BE PROVIDED WITH A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE EXTERIOR. IT M UST TERMINATE IN BACK DRAFT DAMPER AT LEAST 3' FROM ANY OPENING INTO THE BUILDING. THE SIZE OF THE DUCT IS TO BE DETERMINED BY THE DRYER MANUFACTURER, TYPICALLY, A4 DUCT WOULD BE ACCEPTABLE. THE MAXIMUM COMBINED LENGTH MAY NOT EXCEED35' INLENGTH. M15824, TABLEM15024. 2. EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF 488 CUBIC FEET PER MINUTE SHALL BE PROVIDED WITH MAKEUP AIR ALA RATE APPROXIMATELY EQUALTO THE EXHAUST AIR RATE. SUCH MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH A MEANS OF CLOSURE AND SHALL BE AUTOMATICALLY CONTROLLED TO START AN 0 OPERATE SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. IRC M 15830 1. ALL DIMENSIONS ARE TO CENTER LINE OF LIGHT FIXTURE UNLESS NOTED OTHERWISE 2. ALL RECESSED LIGHTING SHALL BE CENTERED IN CORRIDORS AND ALIGNED AS SHOWN UNLESS NOTED OTHERWISE 3. SEE ELECTRICAL DRAW NGS FOR SPECIFIC FIXTURE TYPES AND OTHER INFORMATION 4. ALL FIXTURES AND DEVICES IN CEILING TLE SHALL BE CENTERED UNLESS NOTED OTHERWISE 5. CEILING ELEVATIONS ARE ABOVE FINISH FLOOR UNLESS NOTED OTHERWISE fi. WHEN "ALIGN" IS ON CEILING PLANS GYPSUM BOARD FASCIA ALIGNS WITH FINISH FACE OF WALL ]. ALL ROOMS WITH A SINGLE FIXTURE OR SINGLE RUN OF FIXTURES SHALL BE CENTERED IN ROOM FROM THE WIDEST PART UNO 971 ALUMINUM STEEL PLASTIC PLYWOOD EARTH ® SOLID SURFACE MATERIAL FINISHGRADEWOOD ® GRAVEL W U W 0 Lu W Q W am M M) W ~0 Z U � 0^, Lu U) LL LL (D< Q c) Lu 00 >_ M Emy H" 1`111111 e1. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 ISSUE NO. DATE DESCRIPTION 1 11.10.2]20 PERMITSET PROJECT NO. 20216 PEAKER RESIDENCE DATE: 11182828 G0.02 DRAWING TITLE: GENERAL NOTES & ABBREVIATIONS COPYRIGHT KNOTTY IRON LLC.q­l..mnpmmo �F_�F__ �F _1P_ ^ I I I I I I` I !I I I I I I I I I 0241 10 za 02 00 03 02 00 03 E7 :z'__ 02 00 06 02 00 03 PLAN KEYNOTES 02 00 03 EXISTING WINDOW OPENING TO REMAIN; PREP FOR NEW WINDOW 02 00 06 EXISTING WINDOW TO BE INFILLED 02 00 11 EXISTING TOILET DRAIN TO REMAIN 02 00 12 EXISTING PLUMBING TO REMAIN 0241 02 DEMO EXISTING WINDOW; PREP FOR NEW LARGER WINDOW 0241 03 DEMO EXISTING WINDOW & WALL; PREP FOR NEW OPENING 0241 07 REMOVE EXISTING RAILING 0241 08 DEMO EXSITING WINDOW, DOOR & BRICK; PREP FOR NEW OPENING 0241 09 DEMO EXISTING DOOR & BRICKAS NECESSARY; PREP FOR NEW OPENING 0241 10 DEMO EXISTING ROCK SURROUND; REMOVE EXISTING FIREPLACE; PREP FOR NEW 0241 13 DEMO ALL EXISTING PLUMBING FIXTURES & CASEWORK 0241 15 DEMO EXISTING BUILT-INS 0241 16 DEMO EXISTING NON -LOAD BEARING PARTITION 0241 17 DEMO EXISTING INTERIOR PARTITIONS & DOORS WALL LEGEND 0241 16 7_ Z Lr11177_ L:7/_ J Z Z: :Z _ _ Z::/__ 7_ 7_ L�IIJJ_7_ L LrIlJ_7_7_ II fl �I 0241 16 02 41 09 ENCLOSED PATIO I 02 41 08 I I �I 024113 J 024117 L� Ez1/I U _ LCZ71��T_T_ZZ11�JT_ _TTS} 1 ----------024115 I II I 1 ------------------- 1 DEMO PLAN 1/4" = 1'-0" 020011 BASEMENT C 0*** PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W C) M0 W O Ci) CU W z .. 0 w U) V W V O Lu W 0_ a M IBS Mon TINNIF, so. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: D 6_c L/cF EN C� ., A ; yam; F ;9RC H ITE�',,,c ISSUE NO. DATE DESCRIPTION 1 Ill.10.2020 IPERMITSET PROJECT NO. EXISTING WALL TO REMAIN r� EXISTING WALL TO BE DEMOLISHED _ NEW EXTERIOR INFILL WALL NEW INTERIOR WALL 0241 16 7_ Z Lr11177_ L:7/_ J Z Z: :Z _ _ Z::/__ 7_ 7_ L�IIJJ_7_ L LrIlJ_7_7_ II fl �I 0241 16 02 41 09 ENCLOSED PATIO I 02 41 08 I I �I 024113 J 024117 L� Ez1/I U _ LCZ71��T_T_ZZ11�JT_ _TTS} 1 ----------024115 I II I 1 ------------------- 1 DEMO PLAN 1/4" = 1'-0" 020011 BASEMENT C 0*** PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W C) M0 W O Ci) CU W z .. 0 w U) V W V O Lu W 0_ a M IBS Mon TINNIF, so. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: D 6_c L/cF EN C� ., A ; yam; F ;9RC H ITE�',,,c ISSUE NO. DATE DESCRIPTION 1 Ill.10.2020 IPERMITSET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 D1.00 DRAWING TITLE: DEMO PLAN BASEMENT PLAN KEYNOTES 02 00 06 EXISTING WINDOW TO BE INFILLED 0241 01 DEMO EXISTING EXTERIOR DOOR 0241 02 DEMO EXISTING WINDOW; PREP FOR NEW LARGER WINDOW 0241 03 DEMO EXISTING WINDOW & WALL; PREP FOR NEW OPENING 0241 04 REMOVE SECTION OF BRICK COURSING &WALL; PREP FOR NEW OPENING 0241 05 DEMO EXISTING CONCRETE STOOP; PREP GROUND FOR PLANTING 0241 07 REMOVE EXISTING RAILING 0241 08 DEMO EXSITING WINDOW, DOOR & BRICK; PREP FOR NEW OPENING 0241 13 DEMO ALL EXISTING PLUMBING FIXTURES & CASEWORK 0241 17 DEMO EXISTING INTERIOR PARTITIONS & DOORS 0241 18 DEMO EXISTING WINDOW; PREP FOR SMALLER OPENING; BRICK INFILL AS NESCESSARY 0241 19 REMOVE EXISTING WOOD BURNING FIREPLACE; PREP FOR NEW GAS FIREPLACE WALL LEGEND COPYRIGHT KNOTTY IRON LLC..q­l..mnpmmo 1 DEMO PLAN FIRST FLOOR 1/4" = 1'-0" PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W C) M0 W O Ci) U W z .. 0 w U) V W V O Lu W 0_ a M IBS Mon TIADIF , ONE 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: PD 0 L/c NENOq•••;VSr 8"N'0 1 -7 ,9RCHITE-A ISSUE NO. DATE DESCRIPTION 1 11.10.2020 PERMIT SET PROJECT NO. EXISTING WALL TO REMAIN r� EXISTING WALL TO BE DEMOLISHED _ NEW EXTERIOR INFILL WALL NEW INTERIOR WALL COPYRIGHT KNOTTY IRON LLC..q­l..mnpmmo 1 DEMO PLAN FIRST FLOOR 1/4" = 1'-0" PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W C) M0 W O Ci) U W z .. 0 w U) V W V O Lu W 0_ a M IBS Mon TIADIF , ONE 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: PD 0 L/c NENOq•••;VSr 8"N'0 1 -7 ,9RCHITE-A ISSUE NO. DATE DESCRIPTION 1 11.10.2020 PERMIT SET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 D1.01 DRAWING TITLE: DEMO PLAN FIRST FLOOR PLAN KEYNOTES 02 00 03 EXISTING WINDOW OPENING TO REMAIN; PREP FOR NEW WINDOW 02 00 10 EXISTING STAIR TO REMAIN 03 33 00 NEW CONCRETE SLAB ON GRADE TO MATCH EXISTING 03 35 00 NEW CONCRETE FOUNDATION INFILL WALL 04 20 02 INFILL BRICKTO MATCH EXISTING 05 73 00 NEW METAL RAILINGS 0811 13 NEW EXTERIOR DOOR 08 52 13 NEW ALUMINUM CLAD WOOD WINDOW 10 32 02 NEW GAS FIREPLACE WALL LEGEND JIIIIIIIIIIIIII EXISTING WALL TO REMAIN = EXISTING WALL TO BE DEMOLISHED _ NEW EXTERIOR INFILL WALL NEW INTERIOR WALL COPYRIGHT KNOTTY IRON LLC..„,aa.��g„�a,Ro..ad„m�e.d...,.m�s��m.o��...,.ao��a.,A�,.��oo�,.��.m„w.as.a.a��..,ew�Ana.�,�a.,a„�ao�m�. ���.aengnpmaiomi. 1 PROPOSED BASEMENT 1/4” = V-0" INI_U1.1191a City of Wheat Ridge Building Division W (m) M Z co W C) M0 W O Ci) U LV z r0n W �/ / F0 W 0� ry V O \Lu W 0_ a M IBS Mon TIADIF , $o. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: �.�•\•'•NEN Cq'•• cS'� �RCHITEG c ISSUE NO. DATE DESCRIPTION 1 11.10.2020 PERMIT SET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 A1.00 DRAWING TITLE: BASEMENT PROPOSED PLAN KEYNOTES 02 00 03 EXISTING WINDOW OPENING TO REMAIN; PREP FOR NEW WINDOW 0331 00 NEW CONCRETE STOOP 04 20 02 INFILL BRICK TO MATCH EXISTING 05 73 00 NEW METAL RAILINGS 0601 00 NEW INFILL WALL 0811 13 NEW EXTERIOR DOOR 08 14 23 NEW ALUMINUM CLAD WOOD DOOR AND SIDELITES 08 32 00 NEW ALUMINUM CLAD SLIDING GLASS DOORS 08 52 13 NEW ALUMINUM CLAD WOOD WINDOW 10 32 02 NEW GAS FIREPLACE WALL LEGEND COPYRIGHT KNOTTY IRON LLC­1..mnpmmomi. 1 PROPOSED FIRST FLOOR 1/4" = V-0" 1)0/ PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W o M0 W O Ci) CU LV z r0n w �/ / E W 0 V O \Lu W 0_ a M IBS Mon TIADIF , ONE 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: POO L16 �• v*.•NEN Oq•. 0, -900000 0000- A\ RcHITeo,i ISSUE NO. DATE DESCRIPTION 1 11110.2020 IPERMITSET PROJECT NO. EXISTING WALL TO REMAIN rIIIM EXISTING WALL TO BE DEMOLISHED _ NEW EXTERIOR INFILL WALL NEW INTERIOR WALL COPYRIGHT KNOTTY IRON LLC­1..mnpmmomi. 1 PROPOSED FIRST FLOOR 1/4" = V-0" 1)0/ PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W o M0 W O Ci) CU LV z r0n w �/ / E W 0 V O \Lu W 0_ a M IBS Mon TIADIF , ONE 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: POO L16 �• v*.•NEN Oq•. 0, -900000 0000- A\ RcHITeo,i ISSUE NO. DATE DESCRIPTION 1 11110.2020 IPERMITSET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 A1.01 DRAWING TITLE: FIRST FLOOR PROPOSED PLAN KEYNOTES 02 41 20 REMOVE ALL EXISTING LIGHT FIXTURES; PREP FOR NEW LED FIXTURES 02 41 21 DEMO EXISTING CEILING 1/4" = V-0" U C/ PLAN TRUE COPYRIGHT KNOTTY IRON LLC1 ­1..mnpmmomi. 1/4" = V-0" PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W o 0 0 00 —~O Ci) CU LV z Ow cn CD F0 LU 0� ry Q �.. CD Q Q O W W � -r a M IBS Mon TIADIF , $o. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: PDO Qct �Oe:GNEN pq�•�� R-000000000'- A\ CHITe0,i ISSUE NO. DATE DESCRIPTION 1 11110.2020 IPERMITSET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 A2.01 DRAWING TITLE: REFLECTED CEILING PLANS EXISTING [awl VMTel0 @COPYRIGHT KNOTTY IRON LLC 1 -1... "pmmomi. DINING VAULTED GYP CEILING HIGH POINT ALONG DASHED LINE IS 10'-1" HEIGHT AT EXTERIOR WALLS +- T-6" NEED TO VERIFY THIS LIVING VAULTED GYP CEILING KITCHEN VAULTED GYP CEILING ENTRY VAULTED GYP CEILING PLAN KEYNOTES 02 00 14 EXISTING SKYLIGHT TO REMAIN 06 41 01 NEW WOOD PLANKS ATTACHED TO EXISTING CONCRETE STRUCTURE 08 62 00 NEW SKYLIGHT 26 51 00 NEW LED INTERIOR LIGHTING 2 FIRST FLOOR RCP PROPOSED 1/4" = 1'-0" C'U 0 PLAN TRUE 1 BASEMENT RCP PROPOSED 1/4" = 1'-0" C'U 0 PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W o M0 W O Ci) CU LV z Ow cn CD F0 LU 0 W�O LU W T TT i aVJ M IBS Mon TINNIF, ONE 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: 0 •e•eeeej O�,O•••'�EN O�•••'•�� T': OCHITEG, ISSUE NO. DATE DESCRIPTION 1 11110.2020 IPERMITSET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 A2.02 DRAWING TITLE: REFLECTED CEILING PLAN PROPOSED PLAN KEYNOTES 02 00 03 EXISTING WINDOW OPENING TO REMAIN; PREP FOR NEW WINDOW 02 00 08 REMOVE EXISTING EXTERIOR LIGHT 02 00 09 REMOVE EXISTING EXTERIOR LIGHT; PREP FOR NEW 02 00 14 EXISTING SKYLIGHT TO REMAIN 02 41 01 DEMO EXISTING EXTERIOR DOOR 02 41 03 DEMO EXISTING WINDOW & WALL; PREP FOR NEW OPENING 02 41 04 REMOVE SECTION OF BRICK COURSING &WALL; PREP FOR NEW OPENING 04 20 01 NEW BRICK SOLDIER COURSE TO MATCH EXISTING 08 11 13 NEW EXTERIOR DOOR 08 52 13 NEW ALUMINUM CLAD WOOD WINDOW 26 56 00 NEW EXTERIOR LIGHTING 2 SOUTH ELEVATION_ PROPOSED 1/4" = 1'-0" COPYRIGHT KNOTTY IRON LLC..„,aa.��g„�a,Ro..ad„m�e.d...,.m�s��m.o��...,.ao��a.,A�,.��oo�,.��.m„w.as.a.a��..,ew�Ana.�,�a.,a„�ao�m�. ���.aengnpmaiomi. 1 SOUTH ELEVATION_EMITING 1/4" = 1'-0" ROOF 13- 6 31/32" SOFFIT 9' - 0.. FIRST FLOOR 0' - 0" ROOF 31/32" SOFFIT 9'-0^ FIRST FLOOR 0' - 0" City of Wheat Ridge Building Division W (m) M Z co W C) M0 W O Ci) CU W z .. �0 w VJ V F0 W 0. ry V a 0 W W �_ a M IBS Mon TINNIF, ONE 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: �p,D ,coo vO••'•NE N Q. S� G O 0 O'er 0CH ISSUE NO. DATE DESCRIPTION 1 11.10.2020 PERMIT SET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 A101 DRAWING TITLE: SOUTH ELEVATION PLAN KEYNOTES 02 00 03 EXISTING WINDOW OPENING TO REMAIN; PREP FOR NEW WINDOW 02 00 13 EXISTING OPENING TO REMAIN; PREP FOR NEW DOORS 0241 02 DEMO EXISTING WINDOW; PREP FOR NEW LARGER WINDOW 0241 07 REMOVE EXISTING RAILING 0241 08 DEMO EXSITING WINDOW, DOOR & BRICK; PREP FOR NEW OPENING 0241 16 DEMO EXISTING NON -LOAD BEARING PARTITION 0241 18 DEMO EXISTING WINDOW; PREP FOR SMALLER OPENING; BRICK INFILL AS NESCESSARY 05 73 00 NEW METAL RAILINGS 0811 13 NEW EXTERIOR DOOR 08 14 23 NEW ALUMINUM CLAD WOOD DOOR AND SIDELITES 08 32 00 NEW ALUMINUM CLAD SLIDING GLASS DOORS 08 52 13 NEW ALUMINUM CLAD WOOD WINDOW 08 62 00 NEW SKYLIGHT 2 NORTH ELEVATION_ PROPOSED 1/4" = 1'-0" COPYRIGHT KNOTTY IRON LLC T—„.00,.��.m„w.as.a.a��..,ew�Ana.�,�a.,a„�ao�m�.���.ae... pmo 1 NORTH ELEVATION_ EXISTING 1/4" = 1'-0" ROOF 13' - 6 31/32" SOFFIT FIRST FLOOR 0' - 0" BASEMENT -8' - 10" ROOF 13' - 6 31/32" SOFFIT FIRST FLOOR 0' - 0" BASEMENT City of Wheat Ridge Building Division W (m) M Z co W C) M0 W O Ci) CU W z .. �0 w VJ V F0 W 0. ry V a 0 W W 0_ a M IBS Mon TINNIF, so. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: �p,D O L/C O690.....x. v .SEN 0 ARCH VTC --C) ISSUE NO. DATE DESCRIPTION 1 11.10.2020 PERMIT SET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 A3.02 DRAWING TITLE: NORTH ELEVATION COPYRIGHT KNOTTY IRON LLC..„,aa.��g„�a,Ro..ad„m�e.d...,.m�s��m.o��...,.ao��a.,A�,.��oo�,.��.m„w.as.a.a��..,ew�Ana.�,�a.,a„�ao�m�. ���.aengnpmaiomi. PLAN KEYNOTES 02 00 06 EXISTING WINDOW TO BE INFILLED 0241 01 DEMO EXISTING EXTERIOR DOOR 0241 02 DEMO EXISTING WINDOW; PREP FOR NEW LARGER WINDOW 0241 04 REMOVE SECTION OF BRICK COURSING &WALL; PREP FOR NEW OPENING 0241 07 REMOVE EXISTING RAILING 0241 16 DEMO EXISTING NON -LOAD BEARING PARTITION 05 73 00 NEW METAL RAILINGS 0811 13 NEW EXTERIOR DOOR 08 52 13 NEW ALUMINUM CLAD WOOD WINDOW 2 EAST ELEVATION_ PROPOSED 1/4" = V-0.. 1 EAST ELEVATION_ EXISTING 1/4" = V-0.. ROOF - 6 31/32" SOFFIT 9' - 0" T FLOOR 0' - 0" kSEMENT -8' 10"'-10" ROOF 13' - 6 31/32" SOFFIT 9' - 0" IRST FLOOR 0' - 0" BASEMENT City of Wheat Ridge Building Division W (m) M Z co W o M0 W O Ci) CU LV z Ow cn CD F0 LU 0� ry Q �.. CD Q Q O W W � -r a M IBS Mon TINNIF, ONE 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: O�,O••••NE N Off••••• G • ;F ;gRCHTEG,nc ISSUE NO. DATE DESCRIPTION 1 11110.2020 IPERMITSET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 AIN DRAWING TITLE: EAST ELEVATION IRC 2018 GOVERNING AUTHORITY CITY OF WHEAT RIDGE, COLORADO. ALL CONSTRUCTION TO COMPLY WITH THE FOLLOWING CODES AND AMENDMENTS PER THEIR ADOPTING ORDINANCES 2018 IRC 2018 IECC 2018 IEBC 2018 IPC 2018 IFC 2018 IFGC OCCUPANCYGROUP: R-3 CONSTRUCTION TYPE: TYPE V -B IRC 2018 SECTION N1102: PRESCRIPTIVE PATH TABLE N1102.1.2 CLIMATE ZONE.......................................5B EXISTING - NOT IN SCOPE FENESTRATION U -FACTOR ................ 0.30 GLAZED FENESTRATION SHGC.......... NR CEILING R -VALUE .......................EXISTING ROOF: WOOD FRAME WALL R -VALUE ............. 20 @ NEW EXTERIOR INFILL WALLS MASS WALL R -VALUE ................ EXISTING FLOOR R-VALUE.........................EXISTING IRC 2018 COMPLIANCE 1. DO NOT SCALE THESE DRAWINGS. DIMENSIONS AND CONDITIONS AT THE JOB SITE ARE SUBJECT TO VERIFICATION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS TO THE OWNERS, SINCE PROPOSALS MUST TAKE INTO CONSIDERATION ALL SUCH CONDITIONS WHICH MAY AFFECT THE WORK. DISCREPANCIES IN THE DRAWINGS OR BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE DESIGNER. CORRECTED DRAWINGS OR INSTRUCTIONS SHALL BE ISSUED BY THE DESIGNER PRIOR TO THE COMMENCEMENT OF THE WORK. 2. THE DETAILS SHOWN ARE INTENDED TO FURTHER ILLUSTRATE THE VISUAL DESIGN CONCEPT AND THE MINIMUM WEATHER PROTECTION FOR THIS PROJECT. THE GENERAL CONTRACTOR SHALL INCORPORATE THE REQUIREMENTS OF THE LOCAL BUILDING CODES, STRUCTURAL CONSIDERATIONS, TRADE ASSOCIATION MANUALS, PUBLICATIONS AND RECOMMENDATIONS, AND THE MANUFACTURER'S WRITTEN INSTRUCTIONS FOR COMPLETE CONSTRUCTION OF DETAILS. c��:Z�111xi1�q��9G\I[�7►6yG1:7��:Z�l� �C�]Zi]�Y�1:3�[iZ�]:L\���ylq�:SBi[:L]S:➢ 4. EXTERIOR WALLS ARE 2x6, INTERIOR WALLS ARE 2x4, UNLESS NOTED OTHERWISE. 5. R-20 MIN. INSULATION @ ALL EXTERIOR FRAMED WALLS ADJOINING CONDITIONED SPACE. CONTRACTOR MAY SUBSTITUTE EQUIVALENT INSULATION MATERIALS PROVIDED THAT ALL APPLICABLE R -VALUES ARE MAINTAINED. 6. PROVIDE SOUND ATTENUATION BLANKETS AT ALL WALLS SEPARATING BATHROOMS, POWDER ROOMS, LAUNDRY ROOMS AND MECHANICAL CLOSETS FROM ADJOINING CONDITIONED SPACES. 7. PROVIDE UNDERLAYMENT PER IRC 702.3.7 TO 48" A.F.F. AT WALLS IN UTILITY ROOMS AND BATHROOMS, BEHIND ALL WALLS FINISHED WITH CERAMIC TILE, AND TO A MINIMUM HEIGHT OF +T-0" ABOVE THE DRAIN OUTLET AT TUB AND SHOWER ENCLOSURES. 8. VENTILATION FOR TOILET COMPARTMENTS, BATHROOMS, AND LAUNDRY ROOMS SHALL BE PROVIDED BY OPERABLE WINDOWS OR A MECHANICAL SYSTEM PER 2018 IRC SECTION R303.3. 9. ALL EXTERIOR DOORS LEADING TO UNHEATED AREAS TO BE WEATHER- STRIPPED AND HAVE THRESHOLDS. 10. FLASH ALL EXTERIOR OPENINGS, ROOF/WALL INTERSECTIONS, VALLEYS AND MATERIAL TRANSITIONS WITH FLASHING MATERIAL TO MATCH EXISTING. 11. SAFETY GLAZING IS REQUIRED IN HAZARDOUS LOCATIONS AS DESCRIBED IN 2018 IRC SECTION R308.4. 12. ALL WOOD IN DIRECT CONTACT WITH CONCRETE TO BE PRESSURE TREATED, INCLUDING POSTS & STAIRS. 13. EGRESS WINDOWS TO HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE THE FLOOR, MINIMUM VERTICAL OPENING OF 24", MINIMUM HORIZONTAL OPENING OF 20" AND A MINIMUM OF 5.7 SQUARE FEET OF OPEN AREA PER 2018 IRC SECTION R310.2.1 14. EXHAUST VENT FOR CLOTHES DRYER TO BE VENTED TO THE OUTSIDE. THE DUCT IS TO BE SMOOTH METAL AND HAVE A BACK DRAFT DAMPER. THE DUCT SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH AS THAT RECOMMENDED BY THE MANUFACTURER AND SHALL BE PROVIDED WITH AN IN-LINE BLOWER CAPABLE OF DISCHARGING TO THE EXTERIOR. 15. VENT ALL EXHAUST FANS TO EXTERIOR. PROVIDE RAIN CAPS AND FLASHING AS REQUIRED. 16. CENTER WATER CLOSETS IN THE SPACE PROVIDED OR A MINIMUM, OF 15" CLEAR FROM VERTICAL SURFACES AT SIDES. MIN. 21" CLEAR SPACE IN FRONT OF W.C. 17. PROVIDE BLOCKING AND BRACING FOR ALL EQUIPMENT AND ACCESSORIES (TOWEL BARS, ETC.). 18. GUTTER AND DOWNSPOUT SIZING AND FINAL LOCATIONS TO BE REMAIN AS EXISTING. 19. STAIRWAYS SHALL HAVE HANDRAILS/GRIPS LOCATED 34"-38" ABOVE THE NOSING OF THE TREAD. HANDRAILS SHALL BE NOT LESS THAN 1 1/2" FROM WALL, SHALL NOT PROJECT MORE THAN 4 %" ON EITHER SIDE OF THE STAIRWAY AND BE SIZED PER R311.7.8.5. ENDS OF HANDRAILS SHALL RETURN INTO WALL OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS PER R311.7.8.4. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR MORE RISERS PER R311.7.8. 20. PROVIDE SMOKE ALARMS PER R314: IN EACH SLEEPING ROOM, IN THE IMMEDIATE VICINITY OUTSIDE OF EACH BEDROOM, ON EACH STORY, AND NOT LESS THAN THREE FEET FROM THE DOOR OPENING OF A BATHROOM WITH A TUB OR SHOWER. FOR INSTALLATIONS NEAR COOKING EQUIPMENT, SEE R314.3.1 (IONIZATION ALARMS MINIMUM 20 FEET FROM COOKING APPLIANCES). 21. PROVIDE CARBON MONOXIDE ALARMS COMPLYING WITH 2019 DBCA SECTION R315: OUTSIDE AND WITHIN 15 FEET OF BEDROOM DOORS, IN A CENTRAL LOCATION ON EVERY OCCUPIABLE LEVEL, AND IN A CENTRAL LOCATION IN EVERY SLEEPING ROOM THAT CONTAINS A FUEL -BURNING APPLIANCE. ALARMS CAN BE PLUGGED INTO RECEPTACLES, WITH BATTERY BACKUP, PER 315.6. COPYRIGHT KNOTTY IRON LLC.q­l..mnpmmo AIR BARRIER I INSULATION INSTALLATION THERMAL ENVELOPE IS TO REMAIN AS EXISITING, EXCEPT IN AREAS OF WALL INFILL. IN THESE LOCATIONS, ENSURE DURABLE SEAL OF BUILDING THERMAL ENVELOPE PER N1102.4.1. THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR DIFFERENTIAL EXPANSION AND CONTRACTION GENERAL REQUIREMENTS: THE EXSITING CONTINUOUS AIR BARRIER IS TO BE ALTERED IN ONLY LOCATIONS OF WALL INFILL. A NEW AIR BARRIER SHALL BE INSTALLED TO ENSURE A CONTINUOUS AIR BARRIER ON THE EXTERIOR OF THE BUILDING THERMAL ENVELOPE. THESE NEW BREAKS AND JOINS IN THE AIR BARRIER SHALL BE SEALED. FOUNDATION WALLS: EXISTING -NOT IN SCOPE CRAWLSPACE: EXISTING - NOT IN SCOPE CAVITY WALLS: 5 1/2" - R-21 BATT INSULATION RIM JOISTS: EXISTING - NOT IN SCOPE ROOF: EXISTING - NOT IN SCOPE DUCT INSULATION: SUPPLY & RETURN DUCTS IN ATTIC: ENERGY CODE R-8 WHERE DUCT IS GREATER THAN OR EQUAL TO 3" DIA. R-6 WHERE DUCT IS LESS THAN 3" DIA. SUPPLY & RETURN DUCTS IN ALL OTHER LOCATIONS: R-6 WHERE DUCT IS GREATER THAN OR EQUAL TO 3" IN DIA. R-4.2 WHERE DUCT IS LESS THAN 3" DIA. DUCT SEALING: LESS THAN OR EQUAL TO 4 cfm/100 FTz ACROSS THE SYSTEM OR LESS THAN OR EQUAL TO 3 cfm/100 FTz W/O AIR HANDLER @ 25 Pa DOORS &WINDOWS ALUMINUM CLAD WINDOW I SIERRA PACIFIC I CASEMENT I INSULATED GLAZING UNIT I LoE - 3661 U -FACTOR: 0.291 ALL WINDOWS TEMPERED GLAZING AS REQUIRED PER IRC 2018 ALUMINUM CLAD DOOR I SIERRA PACIFIC I INSWING I AIR-FILLED I LoE - 3661 U -FACTOR: 0.291 NEW EXTERIOR DOOR TEMPERED GLAZING AT AT ALL GLAZED DOORS PER IRC 2018 PIPE CARRYING FLUIDS GREATER THAN 105°F (41 °C) OR LESS THAN 55°F (13°C) SHALL BE INSULATED TO AN R -VALUE OF NOT LESS THAN R-3 PER SECTION N1103.4. A MINIMUM OF 90 PERCENT OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH -EFFICACY LAMPS. N1104. THERMAL ENVELOPE NOTES FOR ANY NEW INFILL WALLS, THE FOLLOWING MUST BE AHRERED TO: 1. THE BUILDING THERMAL ENVELOPE SHALL MEET THE PRESCRIPTIVE REQUIREMENTS OF TABLE N1102.1.2, FOR ZONE 5 OR PROVIDE A RESCHECK. BASEMENT/CRAWL SPACE WALLS SHALL BE R15 CONTINUOUS OR R19 CAVITY, EXTERIOR WALLS SHALL HAVE AN R20 OR R13 +R5 CONTINUOUS. FLOORS OVER UNHEATED SPACES TO HAVE R30, ATTICS/CEILINGS SHALL HAVE R49, WINDOWS TO HAVE A U -FACTOR OF 0.30 MAXIMUM PLEASE PROVIDE ALL VALUES ON PLANS FOR INSPECTOR'S USE IN THE FIELD. IF A RESCHECK IS PROVIDED, THOSE VALUES MUST BE THE SAME AS ON THE PLANS. 2. THE BUILDING'S THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION N1102.4 AND N1101.5. PLEASE PROVIDE A DETAIL FOR EACH BULLET POINT TO DEMONSTRATE HOW EACH COMPONENT'S DESIGN WILL LIMIT AIR LEAKAGE. (THE FOLLOWING SHALL BE CAULKED, GASKETED, WEATHER STRIPPED OR OTHERWISE SEALED WITH AIR BARRIER MATERIAL, SUITABLE FILM OR SOLID MATERIAL.) ALL JOINTS, SEAMS AND PENETRATIONS. SITE -BUILT WINDOWS, DOORS AND SKYLIGHTS. OPENINGS BETWEEN WINDOW AND DOOR ASSEMBLIES AND THEIR RESPECTIVE JAMBS AND FRAMING. UTILITY PENETRATIONS. DROPPED CEILINGS OR CHASES ADJACENT TO THE THERMAL ENVELOPE. KNEE WALLS. WALLS AND CEILINGS SEPARATING THE GARAGE FROM CONDITIONED SPACE. BEHIND TUBS AND SHOWERS ON EXTERIOR WALLS. • CANTILEVERS ATTIC ACCESS OPENINGS. RIM JOISTS JUNCTION. OTHER SOURCES OF INFILTRATION. 3. PROVIDE THERMOPLY OR APPROVED EQUIVALENT AIR BARRIER AT VERTICAL EXTERIOR (COLD) SIDE OF ALL TUB ENCLOSURES, BUILT INS, BETWEEN JOIST/RIM BOARDS, AND TRUSS STEPS. ALL BATT INSULATION SHALL HAVE FULL ENCLOSURE, EXCEPT ATTICS. 4. THE FLOORS AND WALLS COMPRISING THE BUILDING THERMAL ENVELOPE MUST BE PROVIDED WITH VAPOR RETARDERS ON THE WARM SIDE. PLEASE SPECIFY WHAT CLASS OF VAPOR RETARDER IS BEING USED. VAPOR RETARDERS MUST COMPLY WITH SECTION R702.7. SEE TABLE R702.7.1 TO SEE IF PROJECT QUALIFIES TO USE A TYPE 3 VAPOR RETARDER. N1102.1.1 MT� Mnen I K I An rXn nTl KI . 1 BUILDING THERMAL ENVELOPE 1/2" = V-0.. SOFFIT F FLOOR kS EXISTING SEMEN. -8' - 10" S EXISTING City of Wheat Ridge Building Division W (m) M Z co LU O O W O Ci) U W z .. r0n w �/ / Q W V O Lu W � -r a M IBS Mon TINNIF, so. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: k? PQ 0 Lac �RCHITEG c ISSUE NO. DATE DESCRIPTION 1 11110.2020 IPERMITSET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 EC0.01 DRAWING TITLE: ENERGY CODE COMPLIANCE COPYRIGHT KNOTTY IRON LLC.q-l..mnpmm— EXISTING 2x6 EXTERIOR WALL, TYP 10'-5" 12'-4" (3) - 9.5" LVL TRIPLE STUD PACK L (3) - 11" LVL �P\N EXISTING STRUCTURE TO REMAIN TRIPLE STUD PACK �) �t0 R� G' R �J S (3) - 2x10 8 2 2) - x TRIPLE STUD PACK (3) - 2x10 ( N 2UBLE DOUBLE Vtii92� STOOD PACK STTUD PACK 4mLl DOUBLE STUD PACK DOUBLE STUD PACK (2) - 2x8 0 N (3) - 2x10 DOUBLE STUD PACK DOUBLE STUD PACK EXISTING STRUCTURE TO REMAIN (3) - 2x10 (3) - 2x10 6'- 2 1/2" "4-0- peE "o 1 FIRST FLOOR_ STRUCTURAL PLAN 1/4" = 1'-0" (1)0/ PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W o 0 Q 00 —~O � wU LV z Ow cn CD E 0 LU 0 Q � CD Q Q O W LU 00 _ a M IBS Mon TINNIF, so. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: p,DO L/C -n ��•'� NEN N 6% c ,9RCH ITEG,,,� ISSUE NO. DATE DESCRIPTION 1 11110.2020 IPERMITSET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 S1.00 DRAWING TITLE: STRUCTURAL DRAWINGS FIRST FLOOR COPYRIGHT KNOTTY IRON LLC.q-l..mnpmm— EXISTING 2X8 EXTERIOR WALL, TYP (3) - 11" LVL TRIPLE STUD PACK N N O 12'- 8 3/4" 6'- 2 1/2" (3) - 11" LVL (3) - 9.5" LVL TRIPLE STUD PACK DOUBLE STUD PACK 41 1 BASEMENT_STRUCTRUAL PLAN 1/4" = 1'-0" C 0*** PLAN TRUE City of Wheat Ridge Building Division W (m) M Z co W o 0 Q 00 —~O � wU LV z Ow cn CD E 0 LU 0 Q � CD Q Q O W LU 0 _ a M IBS Mon TINNIF, so. 2420 W. MAIN ST SUITE 100 LITTLEON, CO 80120 STAMP: O �p,D L/cF O�,O••••NE N O�•••'• ,9RCH 1TEG,r,c ISSUE NO. DATE DESCRIPTION 1 11.10.2020 PERMIT SET PROJECT NO. 20-216 P EAK E R RESIDENCE DATE: 11.10.2020 S1.01 DRAWING TITLE: STRUCTURAL DRAWINGS BASEMENT 39so G arv�'S aVF G �S � lave. 5c�-'/z 114 3��1 rpt' I Mckr - I a"R Q, o 'o .o rU.rv.ar✓e lao 00o f3TU 4LO100o �"(J Gas raw�t 000 %-r U A/cw gas 1i�c, ON SITE PLANS MUST BE ON SITE FOR INSPECTION ALL Projects are Subject to Field Inspections aahawaairn coca canwuance dy Slusser 12/14/2020 'lanaEamiw Oak �w.uxw•l�gmw.w—aw..�mA L w r�wiry r.waeuuarao-w+w amrxq Y 4.�& CJ S V 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Asbestos Abatement PERMIT - 202100066 202100066 3980 Garrison St Asbestos abatement - 8,640 sq ft total ISSUED: 01/12/2021 EXPIRES: 01/12/2022 *** CONTACTS *** OWNER (7 2 0) 891-1262 PEAKER TRENT SCOTT SUB (303)373-5726 FRANK GRACE 210005 COMPLETE ABATEMENT SERVICES *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 19,025.00 FEES Asbestos Abatement 50.00 Total Valuation 0.00 ** TOTAL ** 50.00 *** COMMENTS *** *** CONDITIONS *** Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section 134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of which require a building permit, occurs or where one or more rooms lawfully used for sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen feet of the entrance to each room lawfully used for sleeping purposes. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this�permrt. I further attest that I am legally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 01/12/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Asbestos Abatement Date: Tuesday, January 12, 2021 10:38:50 AM Asbestos Abatement This application is exclusively for RESIDENTIAL ASBESTOS ABATEMENT YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for residential asbestos abatement? Provide copy of CDPHE State Permit or Stamped Approved CDPHE State Permit Application Yes PROPERTY INFORMATION Property Address 3980 Garrison Street Wheatridge Colorado 80033 Property Owner Name Trent Peaker Property Owner Phone 720-891-1262 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email tp@megastarfinancial.com Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Electronic Payment Form.odf CONTRACTOR INFORMATION Contractor Business Complete Abatement Service, LLC Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) 17514 720-251-5035 Contractor Email fgrace.cas@comcast.net Address Retype Contractor fgrace.cas@comcast.net Email Address DESCRIPTION OF WORK State Permit No. or 20JE6869A Application Approval Date with Initials of CDPHE Employee approving application. Location of Abatement Kitchen,Living Room,dinning, bathrooms, Bedrooms, hallways, basement Square Footage Area 8,640 soft of Abatement Has the abatement Yes been completed If abatement has been completed, upload the clearance report. Project Value (contract value or cost of ALL materials and labor) $19,025.00 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Frank Grace Permit I attest that everything stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Yes Email not displaying correctly? View it in your browser. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Asbestos Abatement Date: Tuesday, January 12, 2021 10:38:50 AM Asbestos Abatement This application is exclusively for RESIDENTIAL ASBESTOS ABATEMENT YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for residential asbestos abatement? Provide copy of CDPHE State Permit or Stamped Approved CDPHE State Permit Application Yes PROPERTY INFORMATION Property Address 3980 Garrison Street Wheatridge Colorado 80033 Property Owner Name Trent Peaker Property Owner Phone 720-891-1262 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email tp@megastarfinancial.com Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Electronic Payment Form.odf CONTRACTOR INFORMATION Contractor Business Complete Abatement Service, LLC Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) 17514 720-251-5035 Contractor Email fgrace.cas@comcast.net Address Retype Contractor fgrace.cas@comcast.net Email Address DESCRIPTION OF WORK State Permit No. or 20JE6869A Application Approval Date with Initials of CDPHE Employee approving application. Location of Abatement Kitchen,Living Room,dinning, bathrooms, Bedrooms, hallways, basement Square Footage Area 8,640 soft of Abatement Has the abatement Yes been completed If abatement has been completed, upload the clearance report. Project Value (contract value or cost of ALL materials and labor) $19,025.00 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Frank Grace Permit I attest that everything stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Yes Email not displaying correctly? View it in your browser. Colorado Department of Public Health and Environment Air Pollution Control Division — Indoor Environment Program — Asbestos/IAQ Unit 4300 Cherry Creek Drive South, APCD-IE-B1 Denver, Colorado 80246-1530 Phone: 303-692-3100— Fax: 303-782-0278 E-mail: asbestos@state.co.us ASBESTOS ABATEMENT PERMIT This permit is granted subject to Colorado Air Quality Control Commission Regulation No. 8, Part P2 adopted December 21, 2007, and effective January 30, 2008, the Colorado Air Pollution Prevention and Control Act (25-7-101 o25-7-501 et seq., C.R.S.) and the following provisions. It is only for the purpose of allowing asbestos abatement ADDITIONAL PERMIT PROVISIONS: By performing work under this permit the abatement contractor agrees that the Division may revok or suspend this permit should the Division find that the contractor: • has violated or has aided and abetted in the violation of 25-7-101 or 25-7-501 et seq., C.R.S. or Regulation No. 8, Part B, or an order of the Division or Commission, • has failed to meet any permit and notification requirement or failed to correct any violations cited by the Division during any inspection within a reasonable period of time, as may be determined by the Division, • has used misrepresentation or fraud in obtaining this permit, or, • has committed any act or omission which does not meet generally accepted standards of the practice of asbestos abatement. As a contractor, you may be subject to other licenses and permits, depending on the requirements ol the county and municipality in which the work is being performed. The Colorado Department of Public Health and Environmen , Air Pollution Control Division strongly suggests that you check with county and municipal authorities in order to deterniii a any other local building/pennitting requirements that must be met. THE ORIGINAL PERMIT MUST BE POSTED ON SITE AT ALL TIMES. Immediately notify the Asbestos/LIQ Unit ofproject modifications by fax (number above) or e-mail (address above) and the appropriate county health department by fax. Project modifications include changes in the scope of work or the scheduled work dates, etc This asbestos abatement permit is valid beginning 12/17/2020 through 11:59 PM on 1/15/2021. The actual scheduled work dates are from 12/17/2020 through 12/25/2020. Approval issued on: 12/16/2020 Fee paid: $400.00 Record number: 164690 Check number: 157159776 - Notice Number: 20JE6869A Project Supervisor: Variance: 11I.N3 Ignacio Monzalvo Comments: None Cerification No.: 8133 For the location specified below: Project AMS: Unnocupied Residence Jonathon Wlazzo Kit, LR, DR, Bathrms, Hallwys, Bdrms, Bas 3980 Garrison St Cerificafion No.: 24795 Wheatridge Project Manager: Jefferson County This permit has been issued to: Issued by: SEK Complete Abatement Services, LLC. 21560 E. 48th Pl. Denver, CO 80249 111"age Elevation Environmental Services Elevation Environmental Services 13340 Harrison St EON at yn�roo,Tf11„1 Thornton CO 80241 (833)536-8476 Asbestos Abatement Clearance Report 3980 Garrison St Wheat Ridge, CO 80033 Prepared For: Frank Grace Ignacio Monzalvo Complete Abatement Services PrepaedBy: Elevation Environmental Services 13340 Harrison St Thornton, CO 80241 CDPHE CERTIFICATE #'s: 24795, 25621 Date(s) of Clearance(s)—January 2, 2021 2 1 P a g e Elevation Environmental Services Table of Contents 1.0 Introduction.................................................................................................... 3 2.0 Visual Inspection............................................................................................. 3 3.0 Final Clearance Air Monitoring............................................................................ 3 4.0 Sample Results................................................................................................ 3 5.0 Conclusion and Recommendations......................................................................... 3 6.0 Lab Results / Certification................................................................................. 4-8 3 1 P a g e 1. Introduction Elevation Environmental Services On January 02, 2021 Elevation Environmental conducted Asbestos Abatement Air Clearances according to CDPHE Regulation No. 8Part B Section III.P (page 46) at 3980 Garrison St, Wheat Ridge CO. Clearance was performed on abatement of ACM texture and floor tile. 2. Visual Inspection A visual inspection was conducted by wearing black nitrile gloves and touching all work and adjacent surfaces to look for any dust or debris left behind. Critical barriers were inspected to make sure they were in place and no dust or debris had passed through. 3. Final Clearance Air Monitoring Aggressive sampling was performed using fans and leaf blowers prior to setting up the samples in the breathing zone. Five pumps were set in the work area and allowed to equilibrate. The pumps were calibrated and PCM cassettes were attached on stands to each. The pumps were allowed to sample until the requirements of NIOSH Method 7400 were met. The pumps were then recalibrated and the average of the two calibrations was used to calculate the volume of air passed through each cassette. [Liters/min] * [Run Time (min)] = Liters Sampled 4. Sample Results Samples were submitted to Reservoirs Environmental which is a NIST approved lab for PCM and TEM analysis. Sample Name Volume Sampled L MAAL (F/cc) Fiber Cone (F/CC) PASS/FAIL 3980-CLO1 1214 0.01 BRL Pass 3980-CL02 1226 0.01 BRL Pass 3980-CL03 1204 0.01 BRL Pass 3980-CL04 1211 0.01 BRL Pass 3980-CL05 1205 0.01 BRL Pass 5. Conclusions and Recommendations The work areas/containments met the standards set forth by CDPHE Regulation 8. Therefore; the area is cleared for the purposes intended. OlPage Elevation Environmental Services 6. Lab Remits/Cantificazions �..._.�_. xeamronuavwoxYex*u.xc .�—•••• .., ,I rm..� also pmeapo IM w eo o_ r, .ti�M1a0 ��....a.,.....m.we..w,.,.e..nm, Lab",F,Q� w a., V. w e."vomo. ten,= sm,..� naw -b w,.wo- 511"age Elevation Environmental Services oa�qes r lm Wmnm nwl, Inr. RM Job As "IM P if ....._..n�..... c.... ..• filPage Elevation Environmental Services 0— i5oloradoEtTiatiment ofWblicfiohh atdEmvonm®r ASBESTOS CERTIFICATION* This cutities that Jonathon Milazzo Cerdneetion No.: M795 has met the reqummnea6 of 25-]-50], C.". and Ab Quality Control Commicsom Regulation No. 8, Part B, end's hereby ardtied by the state of Coloristic on the follmving diuite ine: Air Monitoring Specialist* seats: October ae, 2020 Ezpica: November05, 2021 w.xr mma.. are L SIPage Elevation Environmental Services wV z � e s � E a ° z � U � w 0 op H a '! ,,,,,,,,,_,_" "'~~''''''' _'_'_ ._ ~-'"..:".""_"""~""J",,,,..,-,w.,,.~,,,,,, '- _" ".(,IJt~,-,~. "~'~_' '''"''''-'''-,~'",,, ',' "~""_'W,"~ """"",~,""~,-,,W"l'''' ._,_,..,...""""IJ~"N' . ',. ,QII!AR) _11 OF PLANNING AND DEVELOPMENT Building Pennit NU~ber : - 4234' - , -".BUlLDI......CTlON OMSION -135-2855 CiTY OF WHEAT RIDGE '1QOM$T 29TH AVENUE _ ,'_ WHEAl'AlDGE. <;0 80215 I ,~-, '/.;li.", . :. -- P~ &wrier: property AcI(Itess: 3980 GARRISON ST Contractor license No.: 18603 Company: Sechler Electric Date: 11/19/96 1 iF ~, :t _r J :Jr, .~i .'~l Phone: 423-'7490 Phone :477 5116 0WNERIC0NTIf"~1'~ ~f~~E 0; UN~~~G AND AGREEMENT ~~1IIt - - ,I;=:;=r&~=-=' CQV!lIl8IIIS, fIf.,cOlll; tbeIl ilII__nts shown, and aII8gations ".. _ ....,amf to IIIllO elloondlllolls IlI'Inled on thls ~:mtQ' J ftK ,_ _ noew:~~~~~~ Description: INS'tALL NEW SERVICE AND WIRE HOT TUB ,.4;.. .J' ':"-"1' , Thtal: . $1ADO.00 $45.00 $0.00 $18.00 . $13.00 ~VaIue('-' ," <' .-, ',:-, i~' . .,:,.:', ", '.~ " permit Fee . PlSn Review Fee : Use Tax : - ,.-, 'j<"-' ( BtllEDING OEflARTM!:NT uSE ONLY SIC: Sq. Fl : Approval: Occupancy : Wens: Roof: Stories: Residential Units : Plumbing License No : Company: Mechanical Ucense No : Company: Electrical Ucense No : Company: Expiration Date : Approval : . Expiration Date : Approval: . Expiration Date : Approval : . '," - (1) ~~..!&i!l<lli!il/llllCls.... Ill!' ~ I18tfoltlll1 yopursppbllonsnd .=1oI18lsws<>lthO StsWoICOklIlodo snd II> Ih6ZAln1ng :: .=~~e='~==;~Of(8):::=:::::lI1lh6 ....~-~..:il~"' =:=",_\dOI,mont hao not_one (1) year. w=:;,.... _"'1""""""""'__ (4) . ~~=t..r..w...._"":J:'WIIJ..';=-"'- - 01_ ..,,~~probIsm, (I) ~"','~,' ,\l!t~, " ,:_, ~(24)_lI1_!oroll 8ndsholl____onlnspOCtion, conIbofors (8) ,~~~C=,~sg:t~.._notbo...-toboSpomdllor, "",sn__oI,SIrf~"'thO..-- Sul~'ns THlJPl!RMlTVAUD ONLY wHEN SIGNED BY THE CHlEFBUlLDlNq INSPECTOR AND MAYOR CALLl 234-5933 24 HOURS PRIOR TO INSFiECTION DEPARTMENT OF PLANNING AND DEVELOPMENT " BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: y.;2.3 Y Date: '1/:10/ 'it Property Owner: Property Address: Contractor License No. : Company: iOh 1?4.e~S' 393D q Illlf'.so", ;sT t 1':'6.3 S,EcIlLE;f ,e.L4C'T~ft! ~ Phone: f:23 - 7-190 Phone: 177-.5//C OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value :clO (SDO ""- Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rutes or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat ge ordinancr. f~r work under this permit. (OWNER)(CONTRA~R) SIGNED L. ~ DATE l;jo/~? Description: ::t:~~ ~ rc",W w T4C Total: BUILDING DEPARTMENT USE ONLY ~1iilig!Uom~ Approval: Zoning: PJII~~Q:lflmm~::a Approval: ~Ob1f13WlSf~~rom.Ji~ Approval: Occupancy: Walls: SIC: Sq, Ft. : Roof: Stories: Residential Units: Electrical License No: ttlD Company: ~ ak. do Plumbing License No : Company: Mechanical License No : Company: Expiration Date: Approval: .~~~ Expiration Date: Approval: II IRIllIi!Ilmm1tilf ,j Expiration Date: Approval : III ~!llRi'Jm!~ (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes haye been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or If suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causin9 a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all Inspections and shall receive written approval on inspection card before proceediing with successive phases of the Job. The issuance of a permit or the approval of drawings and specifi,cations shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. (1) (2) (3) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234.5933 24 HOURS PRIOR TO INSPECTION