Loading...
HomeMy WebLinkAbout3690 Allison Courti CITY OF WHEAT RIDGE Building Inspection Division E (303) 235-2855 Office INSPECTION NOTICE +Z-4 r r Inspection . - & Kti`s'. ❑ No one available for inspection: Re -Inspection requir Y No When corrections have been http ✓/www, ci, wheatridge, co, u M at: 1* ► � i City of Wheat Ridge '/� Residential Solar PERMIT - 202000876 PERMIT NO: 202000876 ISSUED: 06/04/2020 JOB ADDRESS: 3690 Allison Ct EXPIRES: 06/04/2021 JOB DESCRIPTION: Installation of a roof mounted 6.72kW Solar Panel System 21 panels, structural required. *** CONTACTS *** OWNER (720)272-4602 FRANK ALEXANDER SUB (385) 482-0045 LEE HATLEY 180271 BRS FIELD OPS, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 15,316.29 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK Scope of Work KW # of Panels Location of Panels Structural required Upload engineer letter or pages on 8 1/2" x 11" only Solar Installation Plan Set on 11'x17" only. Project Value (contract value or cost of ALL materials and labor) 3854820045 permitting.department@blueravensolar.com permitting.department@blueravensolar.com Installation of a roof mounted 6.72kW Solar Panel System 6.72 21 House Roof Yes Frank Residence Wheat Ridge CO Stamped= Permit Pack 4960 Alexander Frank Stamped FLATTENED.Ddf 15316.29 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Solar PV Installation Date: Tuesday, May 12, 2020 2:12:07 PM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 3690 Allison Court Property Owner Name Alexander Frank Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 120-272-4602 arfrank3@gmail.com Electronic Payment Form Frank.odf CONTRACTOR INFORMATION Contractor Business BRS Permitting Name Wheat Ridge 180271 Contractor's License Number (This is a 5 or 6 digit number for the property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for BRS Permitting Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. PA Box 6986 Winds srntlnal Engineering, LLC gyp$ N T 63,' Broomfield CO 80021 3t$ N Ci W E E R l$s allivilinffi 968647055 Oomdatmtldra gnnai/earn May 9, 2020 1403 fourth Research Way, BuddingJ Grand ITT ARMS Abject Cernficaton Water Frank Residence Wheat Ridge, ED At Tu grand K May ranked, A jamete ski up th�mdmcn at the existing firanningavenern was performed boa n audit tes in up Blue Raven order as a request form carry Structural Engineering All review A based an these characters and the dean citing listed bence and unly deemed as lid if purvided inturmai A true and accurate On the acted referenced correct, the on gructural dancing has been reviewed fare round I Be ding the sular Bad dean on the That The laccural review core pride on the second up the on that A ecctlynneanmci,a,nm. PV .aywm and its sanctions elements The sa.ra,asmecimennae seemed on dancing Ade::ne,e eve.IIf mnemnm..an.rn n.e�x., m rm The on structure nr iMPEE damage atsnmpatanshingle an on debate that as.npwasee by As range 024 d2with ceiling juate arcades species The wide have a Man projected himagintal spa n up 14 E , with a supe up IS def The us a A cannested at the ridge on a ridge mard a ad are supparead at the gave by a Be d bearing wall The evight, on fm mine system np(MPIE emceed on e,Ina eMuar,rnwithstand the maemci impre.d extra mmmaan anee suit r panels n.w=piana11 a x. that d�,krHneean,<n. StructuralPV Stitch new An 2 Amendment m EW Abr ad mem�e,��hEdgedSErequired 2:3 aurders01:-aT urled Nie 06 ac upas needed with 4 0 minimum lap pretended derta 11 The specialist the gular gandl shiculd be kept at 72 a T fur landscape a ad 4A a T fur mitint unientathan, with a staingered han up pattern rnensure border eu.•H�Maepnann eeluarAn anhefastener ,ras<em,m, une,n,ingfmmine and supporting The structurea.ry�.e,a,,,<hm,m.,nthe existing structure are required ,n be in a associate pattern on ensure praper e�asnen,han up coding All panels racking and barred re chair be nata lied per manufacturer sperficammy and amid specoad design hureathans All Referendums she 11 be purvided by the manufacturer carry Structural Enginevingassumbe am respicnaboy Nte swmic ce.e. as nut ymrd since ad and Seismic design not ADC: <e Speed opera: VO 1 M� Rid SFO • Applicable Cards -20 iBEIRFas[[a es• Back Dead Lead 9 f•, 20 par lMxel a Back Sphyran Lead- 1� • Wind Speed 130 mph [..pwree spacing30 1 par m.: 5/16 dearrive • embedment z s ince min emem: e:eidn/ONPIENG pini Plega�yntart added aneorthermana.mursumany Wondrous project Ryan Atwell P E woman Engineer WanM. r: i� DQMPIS a15red Bounds Structural Engineering, LLC PO.Box 6986 S- Weight on PV System (Per Clue Faced Solar) 30 pA Broomfield CO 80021 T R U C T U R A L Y Standoff Spacing= 550X 90.861]055 N C F N C R N a N Cr, A P C 66 lb Bomussructual@g me it com on loading Grrviry Loading po=Ground Snow Load- 4B Let p=OC,GIpo (ACCP-E]-1) C, - Exposure Factor= 1 (ACCP -factors) G=Thermal Factor= 1 (ACCP-table]3) =1mpoRanreFactor= 1 p=FM Amo Snow Load- too 0red Ps CA (ACCP-E]-2) Cs=Slope Factor= 1 A Speed Red Auv Wady 3B0)st ad Rad Wad =l pop der Blue Baden Solar) B L Adiutied 10 18 Agree Slope a15red ad System NRight 400 Weight on PV System (Per Clue Faced Solar) 30 pA X Standoff Spacing= 400X Y Standoff Spacing= 550X 6hnNn tAbNary, Sea= 2200tH Point Wads N Sartltlle 66 lb NNe: PV standout are gaggered to ensure proper distnbdlon on loading Bunt Lia Lad -l0 )st None Ad llva load is removed In area's covered by PV army Bat Bead Lad tMR) Composition Shingle 400 PoN Plywood 200 Double Rogers ®24"oc 230 Vaulted Ceiling 000 (Ceiling NA Vaulted) Miscellaneous 070 itlal Bat DL Dead) 90)51 DL Adiucted 10 18 Agree Slope 9bred Frank Rcard ence, Meat Ridge, CO.Sent 2 Damns so-ntlnal Engineering LLC DOM CI S P 0 Boz 6986 i} T R U C T U R A L Broomfield CO 80021 530861]055 N 4i INCRR INC, TDC, DOmussructuallEgmau. corn Member 9lRneee Check Methodology ha new and saying members am sSered and joined together they will deflect the same am o unt She b 1 wu no ml ml ato n s show bow l as ding is Iamb uteri betuw an the two in em be is Loading Summary Inner 7P—d eboof 30 red PV= Spy Loading to traded Member Loading to lEl Member = ENtlw1 Emy 33 364% Based onrehhw member softness, 304 recent of load presto iEi member Dbgot — 9 p9 x Murder 34Mme 29ared name Hsu dome Base Depth Elpsi I El ilbAn. n7) (E)thne, 2A DR 150 556" 1666666 20BO1 33215666 iM Bum, 29 DR 150 125" 1666666 41631 16215625 Loading to traded Member Loading to lEl Member = ENtlw1 Emy 33 364% Based onrehhw member softness, 304 recent of load presto iEi member Dbgot — 9 p9 x 0364 = 29ared BIoA= 30 red x 6364 = 915red PV= Spy z 6364 = 096red Loading to(" Member= Km) = 16215625 = 69b% Elpg. Elm 169496625 Based on relots, member affees, 696 recent of total load presto iEi member Dbeef = 9 paY x 6696 = 659py proof= 30 paY x 6696 = 2095red PV= 3 par z 6696 = 226red Fa no Rasiden cc Me at Ritlge, CO earn DO M E) 5 oomus Structural Engineering, Li T RICI'R RT I. PO.Ban 6986 � Broomlleld GO 80021 3T 1:F61NEERINGLI.G 536801]0.55 Oomuglmtluabeggmad Som Wind Camnlamiona Per MME 716 Comparable and Cladding InPs jjjjj'ud%s ea w�na Maado pi Schedule (Deeply B Ford Shape Gable Foot Ford pope 18 degree, Wan Ford Miele 20P Egpiw Yuind Sued 193N Ground Flawlirn ON — Di wine Pal CAull'om ph— 000256• K, a St a ad a le•VY2 (Ed .26101) Nz(modure Dockhand) =062 Liable 303-11 Kr topogapbichpor— 160 IRe 268111 ad Mind Clougherty Factor— 085 Liable 266-11 Ke Ground Eevlion Factor— 160 V(Desgn wintl&eep)-130ni IRe265-1d) RA Category =ll Liable 1511 ph— 2295 Zone Zone2�d Zone Postiw = 068 679 080 068 S(p— —191 290 —360 045 (Bg.303) haliOPremre — 300cof 5301x[ 661par 311x[ (Fic29A3) ADD haliO Pressure= —1801x[ 3181x[ —396par 961x[ %etndof Spring= 400 400 267 YStndoff Spring= 550 275 275 iniSued — 2260 1160 733 Dead Dead on ettachni 6616 3316 2216 Dentine Call til. MQ 0) Ln lb A7lb 20 lb Standen Call Cal Zone Zone Zone Pestis, = 069 679 080 069 S(p— —195 291 —360 045 (Bg.303) halinPremre — 2561x[ 4861x[ 603par 331x[ (Fic29A3) ABO Cpon Pressure 06Wk—154cof 2921x[ 364par 961x[ %etndon Spring= 660 660 400 YStndon Spring= 350 175 175 iniSued — 2160 1050 700 Dead Wax on ettachni 6360 3150 2160 Dealing CpllinMQ ) Som 275 lb xL lb Standen Up Check eammhm Design Salm= -330 In Sendoff Uplift Sapamv=456 In 450 In mpactp330 In demand therefore, CK FvddnerCnpacTy Cheek Fastener- 1 546did Lag Numberol Fase -1 Embadmam Depth =25 Poll Sabi Per Inch =x56In Faxen,Samar-625In 4 FG rd 158SCE rd 16-667th6672 m capacitn 330 m demandtherefore,CK ay i� Bourns Structural Engineering, LLC DQMPI5 PO.Box 6986 S -c- T R U C T U R A L Broomfield CO 80021 530 861]055 :EF NQ TNEER INC, LLC BomusAructual(@g me it com (MPT) PABB-NM Framing Blgm@s w=26P6 Bead Wad 29 pA Pvlmd 10pA Show Load 91 pA altersel Governing lmd Combo -DL,SL Member Cpan=ffi-0" Se Road Wad 130lel Member RoFedies-Basel on BFgn@d 3eNon Member Size 8QPCi) Iidea) LumberGp/Gr Member Spacing end 756 2"0 BF10 ®24"oe Mock Sending 9rei PoFel) = Vb A Ctl A Cr A Cr (NDS Table 431) 900 A 115 z 13 z 115 Allowed Bending Stress =154]3 psi Maximum Moment=rWL°2)1A = 6361265 XA =]6aaAA Int Actual Bening titres= Maximum MomerA)/ B 10094psi FAoneda Annual -653%Suressed - Threlee, 0 Check Bygljclion Allowed Deduced (Total Load) = w (E= 1 Scope psi Per NDS) 09631n Selected Criteria Basel on = Simple Span Actual Detlectlon(Total ked) _ (Anc LuD I(SVF1) 0b16m =1249 > LAN Therefore Be caa Allowed Deduced ur Wada = 1240 07in �� Actual Detlectlon(Bve Load) _ (Anc LuD I((SVF1) 04761n LAD2 > L240 Therefore Be Check %ear MemberArea - Aa lni Fvpsi) =1Npsi (NDB Table 4A) Cooked Shear =w•A 105 to Max Shear M=w'L12= 1wb A lwreda Annual -12 3% Suressed - Threlee, 0 Frank Rcard ence, Meat RiIBe, C0 Sam 5 g� Domna Structural Engineering, LLC i*OMuS PO.Box 6986 S - T R U C T U R A L Broomfield CO 80021 90.861]055 NQ T N E E R I N C L R f BCmnasruclnal@gmau earn FaminBCbec�KLNL Ssier (Mpi PPBB Check Bending Shess Fbpsi) = Vb x Cd x a x Cr (NBC Table 431) 900 x 115 z 12 z 115 NlOwel Bmtllpg Stress =ID2wapsi M&amun Moment=rWL°2)1S 14570aa XA - 174w44 In# Mal Bending Stress =(M&amum Moment) 1 B Showed a Pdual-9l 2% Shamed - Therefore, Be drank non Colonel Defection Q01al Load)= w (E= 1700000 psi Per NDS) 0963177 Detlep10n O9erh Baretl on = Simple Span Mad Wllep10n (T01al Lxtl)= (COUP)I((SVF1) 0616177 =1249 > wSe Tber0ve0B Colonel Defection ped Wada= 1240 w=C9P9 Deatllmtl 66ptt /%.6377»771 PV Load 22pst Snow Load 210 pst 2`C centers ®24"0c Li > 1240 TWWNWOB Cover Load Combo =DL,BL Member Span =19'-0" itlal Wad 297 pop (NDS 4161 4A) dShear NlOuetl Shear = N' A =196816 Member RspeNes Member Size 8Onla) Iidea) LumberSpVCr Member Spacing 2R la 14 4]R BF0 ®24"0c Check Bending Shess Fbpsi) = Vb x Cd x a x Cr (NBC Table 431) 900 x 115 z 12 z 115 NlOwel Bmtllpg Stress =ID2wapsi M&amun Moment=rWL°2)1S 14570aa XA - 174w44 In# Mal Bending Stress =(M&amum Moment) 1 B Showed a Pdual-9l 2% Shamed - Therefore, Be drank non Colonel Defection Q01al Load)= w (E= 1700000 psi Per NDS) 0963177 Detlep10n O9erh Baretl on = Simple Span Mad Wllep10n (T01al Lxtl)= (COUP)I((SVF1) 0616177 =1249 > wSe Tber0ve0B Colonel Defection ped Wada= 1240 C� 0m /%.6377»771 Mad Wlleetlon gr Wada = (twLw)1(SVF9 0477177 Li > 1240 TWWNWOB McmisnNew 9177"2 Fv Qosl)=1axSh (NDS 4161 4A) dShear NlOuetl Shear = N' A =196816 Max Shear (V)=w' V 2 = 41616 Showed a Pdua1-213%Shamed - Therefore, Be Frank Residence, Masi CO. dsm6 (E) (E; 1X DECKING OR SHEATHING (N) INSTALL SIMPSON A34 CLIP. (N) SISTER MEMBER TO BE FULL LENGTH. ATTACH TO (E) RAFTER W/ SIMPSON SDVV22300 SCREWS STAGGERED TOP AND BOTTOM @ 16" O.C. MINIMALLY NOTCH NEW ` (E) CEILING JOIST SISTER RAFTER TO BEAR DIRECTLY ON (E) TOP PLATE OF WALL. OPTION 1 - FULL LENGTH SISTER SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE. SISTER RAFTER TO BEAR DIRECTLY ON (E) TOP PLATE OF WALL. OPTION 2 - OVERLAPPED SISTER SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE. (N) SISTER RAFTER (N) SISTER RAFTER (E) RAFTER SECTION A -A SISTER UPGRADE OPTIONS (N) INSTALL SIMPSON A34 CLIP. TER MEMBER TO BE FULL IGTH. ATTACH TO (E) RAFTER W/ PSON SDVV22300 SCREWS kGGERED TOP AND BOTTOM @ O.C. ALTERNATIVE FASTENER SCHEDULE: 10d NAILS STAGGERED TOP AND BOTTOM AT 6" O.C. Domus Structural Engineering, LLC. P.O. BOX 6986 Project Number: Solar PV Project Description: Rafter sister upgrade detail and Drawn By: JAC Drawing Name: Broomfield, CO 80021 specifications. Revisions: (530) 864-7055 A S i S i Domusstructural@gmail.com B GENERAL NOTES AERIAL VIEW CODES AND STANDARDS NATIONAL C CODE z DRAWINGS HAVE BEEN DETAILED ACCORDING TO OUSTING REQUIREMENTS INTERNATIONAL BU I TO ING CODE pBe) SAM INTER xwioxu RES I DENTAL CODE p Be) SAM INTERNATIONAL PILL ABING CODE 0 PC1, ANO ALL STATE AND LOCAL eD I w ING, QTS FAL, AND PLUMBING CODES SITE NOTES IOSHA REGULATION 2 THE FVMODURSARECONSIDERED NONCOMBUSTIBLE AMID THIS SYSTEM IS AN UTILITY INTERACTINE SYSTEMWITH NO STORAGE BATTERIES 3 THE SALES FVINSTALLECTION SHELF NOT OBSTRUCT PURPLUMBING MECHANICAL OR BUILDING ROOF \KENTS 4 ROOF DWARINGS SHALL BE DESIGNED INSTALLED AND MANSTANED INACCORDANNEWTH THIS CODE AMID THE APPROVED MANUFACTURERS INSTRUCTIONS STAFFORD THE ROOF COFFERING SHELF SERPIETO PROTECTTHE BUILDING OR STRUCTURE SO LA A CONTRACTOR 2 IF APPLICABLE MODULE GROUNDING LUGS MUST BE INSTALLENAT THEMARKED GROUNDIN LUG HOLES PER THEMANUFACTURERS INSTALLATION REQUIREMENTS 3 AS INDICATED By DESIGN OTHER NRTL LISTED MODULE GROUNDING PRICES MAYBE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION NOT MEENT10 LIMIT UP SEARS AS REQUIRED BYRELD CONDITIONS 5 CONDUIT POINT OF PENETRATION FROM EXTENDS TO INTERIORTO BE INSTALLED AMID SEELEDWITH ASUFABLE SELLING COMPOUND 6 DC WIRING LUITEDTO MODULE FOOTPRINT WIMPURESEAC SYSTEM 7 ENPHASEWRING SYSTEMS SHALBE LOCATED AMID SECURED UNDER THEARI SUITABLE AN I NO CLIPS 8 MAP DC \ALTAGE CALCULATED USING MANUFACTURER PROCEED LESS COEFFICIENT FOR We UNLESS NOT ANCELABLE 9 ALL INVERTERS MOTOR GENERATORS PHOTOPOLTAC MODULES PHOTOPOLTAC PANELS PC SHADOW LAC MODULES DC COMBINERS DC TO DC CONDEATERS SOURCE CIRCUIT COMBINERS AMID CHARGE CONTROLLERS INTENDED FOR ixAPHOT AALwc POWER SYSTEM SPECIFICATIONS10 ALL SIGNAGETO BE PLACED INACCORDANCEWTH LOCAL BUILDING CODE 11 TERMINALS AMID FLORAL BETIGHTENEDTO MANUFACTURER TORO UP WHEN PROMDEEN Ix ACCORousEWTH NEC CODE nO AID) ON ALL ELECTRICAL CONNECTIONS. EQUIP MEW LOCATIONS Eam GANG PROPOSED ELECTRICAL EQUIPMENT WILL BEPROVIDENAS PER SECTION NEC 2 EQUIPMENT INSTALLED IN DIRECT SUNLIGHTMUST BERATED FOR EXPECTED OPERATING TOTHE FORLORN DISCONNECT OR PALANTIR SIGHT OFTNEUTILTYARC DISCONNECT 4 ALL EQUIP MEW SHALL BE IN STAFF ED ACCESS I BLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES 5 ALL COMPONENTS ARE LISTED PARTNER PURPOSEAND RATED FOR OUTDOOR USAFEWHEN POP ROPRIATTE tyM Whcagl:R@ CRAMUNIN AIMINT APPROVED Revlawe6fOCW Comgl m 6,3 ZDZD Plans EAammer Gale p...=wra,dw�Gw�A=e PAY Currey CONTRACTOR FRE FIELD OFF 385 498 6700 T BLUE RAVEN G U mor ANN I RESEARCH WAY IxeL Z BE Uies. Z Z0 DESIGN CRITERIA SITE SPECIFICATIONS 800 377 CAN g -WIND SPEED. 130 MPH OCCUPANCY - R3 Pvi-COVER SHEETQ o 0 GROUND SNOW LOAD .43OFF CONSTRUCTION -V -B o_ PROPERTY PLAN 2 M U CONFIDENTIAL THE INFORMATION Roof Show LOAD. 30 PSE ZONING'. RESIDENTIAL PAX -STEPLAN HEREIN COMPARED SHALL NOT BE URI IwwE EXPOSURE FACTOR c PV4-EQUIPMENT USED FOR THE BENEFIT OF ANYONE EXCEPT F qBLUERAFTENSOLEAS SEISMIC DESIGN CATEGORY B NOR SHALL ITBE DISCLOSED IN MOLE OR IN SINGLE LINE DIAGRAM ELECTRICALCALCULATIONS& ? Q PC m EDEDAN SCOPE OF WORK ELECTED CAL NOTES PACT TO OTHERS OUTSIDE U) INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM PV]- RECIPIENTS ORGANIZATION I. Ar.Kira EXCEPT IN PARSEC TOM AND THE (IF NEEDED) SAFE AMID USE OF THE PERSEPHONE Carey 8 72 MN OC PHOTOVOLTAIC SOLAR ARRAY PVB- LABELS & LOCATIONS RATE WRITTEN PERMISSION OFBLUESOMENSOLEAS 0 FEE CUSTOM DIRECTORY PLACARD MODULES(21)mnaa20 TO (IFNEEDED -NEC 69056(B)) Apri1232020 INVERTER(S) Enphase107 Mlerolnverters— iXee J RACwaUna°SFM Infinity fNABCEP Not PAY Currey CONTRACTOR FRE FIELD OFF 385 498 6700 Z DESIGN CRITERIA SITE SPECIFICATIONS SHEETINGEX g -WIND SPEED. 130 MPH OCCUPANCY - R3 Pvi-COVER SHEETQ o 0 GROUND SNOW LOAD .43OFF CONSTRUCTION -V -B Pi PROPERTY PLAN 2 M U Roof Show LOAD. 30 PSE ZONING'. RESIDENTIAL PAX -STEPLAN D D o IwwE EXPOSURE FACTOR c PV4-EQUIPMENT &ATTACHM ENT DETAIL =W SEISMIC DESIGN CATEGORY B Pi RAW SINGLE LINE DIAGRAM ELECTRICALCALCULATIONS& ? Q PC m EDEDAN SCOPE OF WORK ELECTED CAL NOTES m Q INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM PV]- MAIN BREAKER DERATE CALCS. I. Ar.Kira (IF NEEDED) Carey 8 72 MN OC PHOTOVOLTAIC SOLAR ARRAY PVB- LABELS & LOCATIONS RATE ROOF TYPE Comp Shingle FEE CUSTOM DIRECTORY PLACARD MODULES(21)mnaa20 (IFNEEDED -NEC 69056(B)) Apri1232020 INVERTER(S) Enphase107 Mlerolnverters— iXee RACwaUna°SFM Infinity 73079694AppI Not taIII Ne>rA1.. Na,.,..a....a f .c COVER SHEET xA Non NEC xso.. ground .LER ,w,PRV1NUMBER .�H0 3)Natural Gas rbond of wm.ac.,acaa Water bonding ... Non NEC mr.l. xso.. o.LeN �� 0 LEGEND IrN BORDER BDODISCONN AT BLUE RAVEN 3690 Alison court oMEaeePANSEL I(B LORD CENTER o AN DISCONNECT ORE FLOODS 800 377 CIA IM] N LTYMETEe BLUERANNSOLER COAL CONFIDENTIAL THE INFORMATION IMS MAN a�CEP�� HEREIN CONTENDED SHALL NOT BE e rNIe.ee. oR USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERFASANSOLER NOR SHALL IT FRONT OF HOME BE DISCLOSED IN MOLE OR IN 0 TRANSFER SWITCH PAYTO OTHERS OUTSIDE RECIPIENTS ORGANIZATION o COMBINEReeXAGeeEGATee EXCEPT IN FORCED TION COLD THE SALE �NNABCEPrrPeE PVREVENUEMETER P® EQUIPMENT WRITTEN PERMISSION ERANNSOLER FIRE SETBACK ES RUN eCODUIT IN FIELD) CERTIFIED PwuIaCnaING PV INSTAUATION ESSIONAL PROFAM PROPERTY LINE Gurr SCALE 1A6-1 _ CONTRACTOR ERE FIELD OPS BY 385 498 6700 AS AS IN ED AD IF AS IF IF AD PC OF OF Z O Y Q0 U U W O o_ W ZON WPC OF PC x ON ON S Q DRAHING By Kira Carey DATE AP123 2026 cqr misrxuu 079694 MHATNADE PROPERTY PLAN ADrPV2 EV1e1 FRONT OF HOME z CHIMNEY LEGEND Nor - INv INVERTER BOCOIPC.NNIOr BLUE RAVEN SUB (E) SUBPANEL o Lc IN) LOAD CENTER qc Lqc 1403N RESEARCH wAY, BUILDING J OREM, UT 84097 Ac AC DISCONNECT 800-3774480 Wti BLUERAVENSOLAR COM UTILITY METER CONFIDENTIALTHEINFORMATION MSP MAIN SERVICE PANEL HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EACEPT BLUERAVENSOLAR NOR SHALL IT 6E DIscLOSED IN WHOLE OR IN Ts TRANSFER SWITCH PARTTO OTHER SOUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CORNEA TION WITH THE FC COMBINER BOX/ACGREGATOR SALE AND USE OF THE RESPECTIVE PV PV REVENUE METER EQUIPMENT, WITHOUT THE WRITTEN PERMISSI ON OF LLC. ®BLUERAVENSOLAR FIRE SETBACK EMT CONDUIT RUN p(� NABCEP (TO BE DETERMINED IN FIELD) CERTIFIED Lfc Iqc PV WIDE STRING PV INSTALLATION PROFESSIONAL PROPERTY UNE SmttGurney c MPV 011719 01 5 866 CONTRACTOR: SCALE: 1/8"=V-0" BRS FIELD OPS 385.498.6700 ® ff. LBC &C 9c o Lfc qc Lqc O o ED ffc*&Ctic Lfc Lfc Iqc Lqc 000 c 0 0 ticoOc o Z m MP1 O `o D n #OF MODULES: 21 abs Q o U n AZIMUTH:90' 2 m U PITCH: 18° [If L BE ai TSRF:80% LL .- a. AREA: 731 SQ. FT Z z BE Q OVERHEAD SERVICE LINE X o ) EE (n Q Sealed For Existing Roof & Attachment Only STRUCTURAL UPGRADES REQUIRED ON MP1 THAT DIRECTLY SUPPORT SOLAR PV. 2X8 SISTER UPGRADE REQUIRED. SEE STRUCTURAL DETAIL AND CALCUALTIONS PACKAGE FOR ADDITIONAL INFORMATION. Ryan M. DlNAIly signed by Y Ryan M. AW ll Atwell ll'0100I'. DRAWING BY Kira Carey DATE April 28, 2020 PROJECT NUMBER 73079694 SHEET NAME SITE PLAN PAGE NUMBER REVISION PV3 PV ARRAY INFORMATION PV MODULE COUNT: 21 MODULES # OF ATTACHMENT POINTS: 47 ARRAY AREA: Module Count x 17.51ft' = 367.7ft' ROOF AREA: 2536.Oft' OF ARRAY/ROOF: 14.5% ARRAY WEIGHT: Module Count x 50lbs = 1050.Olbs DISTRIBUTED LOAD: Array Weight +Array Area = 2.861bs/ft' POINT LOAD: Array Weight +Attachments =22.3lbs/attachment V Infinity IMRAIL v Trina 320 PV MODULE (E) ROOF MEMBRANE UNIRAC SLIDERS AND TRIMRAIL ROOF ATTACHMENTS FLASHING 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE Unirac SFM Infinity SRM RACKIN O ATTACHMENTS TO BE Uni2c5FM Infinity FRAME STAGGERED BY SHIFTING EACH SUBSEQUENT ROW OF ATTACHMENTS G\ ON E RAFTER OVER. /IT N WIDTH ROOFTYPE: Comp Shingle ROOF FRAMING TYPE: Rafter Scale: 3/8" = 1'-0" PORTRAIT LANDSCAPE ARRAY DETAIL, SIDE VIEW Scale: 3/8" = Vi RAFTER OR TOP CHORD(TRUSS) 2x6 @ 24"O.C. CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x6 @ 16"O.C. Sealed For Existing Roof & Attachment Only Trina 320 PV MODULE (BEHIND TRIM RAIL) Unirac SF Infinity TRIM RAIL MP1 THAT DIRECTLY SUPPORT SOLAR PV. WITH 2-1/2" MIN. EMBEDMENT PORTRAIT 1-11 STRUCTURAL DETAIL AND CALCUALTIONS MEMBRANE PACKAGE FOR ADDITIONAL INFORMATION. 48" MAX. r�Ql� MAX. 0 m O LANDSCAPE `0 H rc MAX. 0 U MAX. m LL C) c N m LL ARRAY DETAIL, FRONT VIEW SRM RACKIN O ATTACHMENTS TO BE Uni2c5FM Infinity FRAME STAGGERED BY SHIFTING EACH SUBSEQUENT ROW OF ATTACHMENTS G\ ON E RAFTER OVER. /IT N WIDTH ROOFTYPE: Comp Shingle ROOF FRAMING TYPE: Rafter Scale: 3/8" = 1'-0" PORTRAIT LANDSCAPE ARRAY DETAIL, SIDE VIEW Scale: 3/8" = Vi RAFTER OR TOP CHORD(TRUSS) 2x6 @ 24"O.C. CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x6 @ 16"O.C. Sealed For Existing Roof & Attachment Only Trina 320 STRUCTURAL UPGRADES REQUIRED ON PV MODULE MP1 THAT DIRECTLY SUPPORT SOLAR PV. WITH 2-1/2" MIN. EMBEDMENT �a (E) ROOF STRUCTURAL DETAIL AND CALCUALTIONS MEMBRANE PACKAGE FOR ADDITIONAL INFORMATION. r�Ql� UNIRAC SLIDERS FLASHING STRUCTURAL UPGRADES REQUIRED ON 5/16" STAINLESS STEEL LAG BOLT MP1 THAT DIRECTLY SUPPORT SOLAR PV. WITH 2-1/2" MIN. EMBEDMENT 2X8 SISTER UPGRADE REQUIRED. SEE AWASHER STRUCTURAL DETAIL AND CALCUALTIONS (E)) BUILDING STRUCTURE PACKAGE FOR ADDITIONAL INFORMATION. Nor - BLUE RAVEN 1403N RESEARCH WAY, BUHMNO J 0REM, UT 84097 800-377-4480 WWW BLUERAVENSOLARCOM CONFIDENTIALTHEINFORMATION HEREIN CONTAINED SHALLNOT BE USED FOR THE BENEFIT OF ANYONE EACEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scot Gurney M PV 01171 9 01 5 866 CONTRACTOR: BRS FIELD OPS 385.498.6700 PROJECT NUMBER R)/8D M. oIp ilysl9"a fiYN'" 73079694 Atwell 050002005.0615.15.14 SHEET NAME EQUIP. DETAIL RAG E NUM BER R yIAN0 PV4 c+� c+� O O Z 0 m O `0 H c 0 U 2 D= m LL C) c N m LL 0 W Z_ � Q LU H x N L (n Q M DRAWN. aY Kira Carey DATE April 28, 2020 PROJECT NUMBER R)/8D M. oIp ilysl9"a fiYN'" 73079694 Atwell 050002005.0615.15.14 SHEET NAME EQUIP. DETAIL RAG E NUM BER R yIAN0 PV4 STRUCTURAL UPGRADES REQUIRED ON MP1 THAT DIRECTLY SUPPORT SOLAR PV. 2X8 SISTER UPGRADE REQUIRED. SEE STRUCTURAL DETAIL AND CALCUALTIONS PACKAGE FOR ADDITIONAL INFORMATION. Sealed For Existing Roof & Attachment Only Ryan M. d by RyanMAhvell Atwell °so°000a 5 IX DECKING OR SHEATHING BLUE RAVEN (N) INSTALL SIMPSON A34 CLIP. 1406 N RESEARCH WAY, BURLINGJ OREM, UT 84097 800-377-4480 (E) RAFTERS WWW BLUERAVEN SOLAR COM (M LENGTSISTERH. . ATTACH TO BE FULL LENGTH. SOW22300SCEWS WI HEREINC CONFIDENTIALTHEINFORMATION STAGGERED TOP SCREWS HEREINCONTAINEDFOR THEOEN FAIL NOT BE STAGGERED TOP ANO BOTTOM usEO FOR THE BEN of Is' O -C. ANYONE R NOPTBLUE R BE DISCLOSED ISCLO E LAR NOR E OR I T eEOls T0OT IN WHOLE OR IN PART To OTHERS NIZATION REaIN CONTSN EC LION WITH SALE EAND USE OFTTI ONWITHTHE sALE AND usE of THE RESPECTIVE MINIMALLY NOTCH NEW �flCEILING JOIST E OUIPM ENT, WITHOUT THE WRITTEN PERMISSION OF SISTER RAFTER TO BEAR BLUERAVENSOLAR LLC. DIRECTLY ON (E) TOP PLATE OF WALL. NABCEP OPTION 1 - FULL LENGTH SISTER CERTIFIED SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE- PV INSTALLATION PROFESSIONAL AcAttGumey M PV 011719 01 5 866 CONTRACTOR: r 7X DECKING OR SHEATHING B RS FIELD OPS I 385.498.6700 (N) INSTALL SIMPSON A34 CLIP. (E) RAFTERS (N) SISTER MEMBER TO BE FULL ' LENGTH. ATTACH TO (E) RAFTER W1 M A. �A SIMPSON SDW2230O SCREWS STAGGERED TOP AND BOTTOM Q O ID Z m U `o 1 Q c o O U MINIMALLY NOTCH NEW (E) CEILINGJOIST [If2 CBE )SISTER RAFTER TO BEAR U DIRECTLY ON (EI TOP PLATE LL Of OF WALL. Z OPTION 2 - OVERLAPPED SISTER LUo SEE LETTER FOR UPGRADE LAP LENGTH AND SIZE. U Q M (N) SISTER RAFTER DRAWING BY Kira Carey 1, DATE April 28, 2020 (N) SISTER RAFTER RAFTER qq �B4 PROJECT NUMBER SECTION A -A 73079694 SISTER UPGRADE OPTIONS SHEET NAME EQUIP. DETAIL ALTERNATIVE FASTENER SCHEDULE: 10d NAILS STAGGERED TOP AND BOTTOM AT 6" 0 PACE NUMBER REVISION PV4 1 0 14 mAWN4win ZCU.,m IW 90Au w<ax lil JE-iV-eW/C,mIM/�xw;sWow uoa lu ai iV-nlvNy W/4iIINWMVMx# nun Vl �z-zrz-u> Nrmw-ycu aaos 15 w mAWmx/Nxmacw PFnlw MVAC mv. z m .1 lu 9AWGsAREcuIEsiEI my w m.Wcma,/3m.N-icN.. xNNCINI w mnwonderful Nm'x ClC,m¢«Itttt [ INIthal EMMI BLUE RAVEN -L EXPOSED T 2 TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS O "DEN IN G J PROVIDED) w ACCORDANCE FILL NEC CODE 110 TAP) ON ALL ELECTRICAL CONNECTIONS Uvee. Ureami 3 CONDUIT AND CONDUCTOR SPECIFICATIONS JOSE BASED ON MINIMUM CODE REQUIREMENTS AND JOSE NOT MEANT TO LIMIT UP SID]NG AS REQUIRED BY FIELD CONDITIONS 800 377 NON BLUEFEREFURSOLAY COM (211Ta UL 1703 COMPLIANT HEREIN COMPARED SHALL NOT BE USED FOR THE BENEFIT 0 F c2l) Enphase IQ7 Micronviefter, MICRO ANYONE EXCEPT INVERTERS BLUERGAGENSOLAY NOR SHALL IT UL 1741 COMPLIANT BE DISCLOSED IN MOLE OR IN 11 MAN FOR ALL SUB BRANCH PACT TO OTHERS OUTSIDE 10 aPAa10PAT JUNCTION e Ux CIRCUIT T UO COMPPVANTN 6 ORGANIZATION "aR1° By3 (OPTIONAEIO UPq EXCEPT IN COURSE TIONWTHTHE aORECIPIENTS Ro:Jn CABLE ERUm vuHieom P BY BE PA THE WRITHEN PERMISSION OF �ooAMAN t[RUCE — _ w�.ToowLAi.i a (EABBI MAN BREAKER (yoAP (1)CIRCUIT 0 oMOOUJEs MUER200A POPPY DROOPSR Ir Ar NABCEP METER LOCKABLE XSIB SOPER CERTIFIED B Logo L2 114 PV 11vsTA2wT1o1v 2 JUNCTION BOX 1 PROFesslomA2 (1) NEC aPNTRA PF op uOOULLs TOR �CJpoarzP L222 L2 L2 CONTRACTOR I NIH BRS FIRE 6 00 385.498. E100 1202Q VAN 1 PHASE TO UTILITY AN HERE COMB SEE B GO PULL BE J 3 2 1 0 RID uCESSIBLETO Unuiv COMPANY 307 PV BREAKER TO BE LO RATED OPPO SITE O END OF E US SING FROM MAN BRANCHESGrytl TO CD CD ELECTRODE N fHt ^v^^ 0 H- ED Z Np l 0 y 1tNa n0uulemb M1rvegeeunYNginstalled pnpaX 111e! t FLY o N Article 260 1 U Jnaphy. 2)I!UE90�ennl available provide supplemental U PC ground milks I NECAGRI sg(NfD. 1 The elf obtained MARBLE Or be in compliance U llun LL S)Nalur Caub Cold Water bonding pv3gl] NECAX)cle 399.19µa) ;; 0ON m W 1 RE Z Q> 2 The PV du have mCD m nee ,� re m the one sae terminalsI N N ON(top of meter block) � m o m x o mall be marked wth a Sam ped Smog aluminum or Iw By stainless steel tag endicading the address including Kira Carey WS U SEE TO D TO E ARTS GS OF the requirements Or Meter n msaelUn ulme c AN SPACE AND PAID ELBOARE BE ial HESUA LL PER CEN T OF THENmreeTERE) OUTPUT uttermell located vlH mn AIR CUP AN BY EN T AN D TO E RATIN 0 OF TO E OVER AN BY ENT D PROJECTS 0 THE J. The PV)ASO AP123 2020 the existing tility ter are AN SAFE SHALL NOT Eve SEE TO E BROADLY OF THE AN S R. a6ore mueanst NUMBER079694 ONE TO E UTILITY AND TO E 0 TITER AN INVER TER Ad E LOCATED ATwHERETE EN BE OF A sany reason this be accrnpi picked e AN SAFE THAT CON LANE LOAD S THE SUM OF 125 NEFF ENT OF TO E ERryT ANT LLT hall be uhn died Or review The I meter AIR CUP AN BY EN T AN D TO E RATIN 0 OF TO E OVER AN BY ENT D EXACE PROJECTS 0 THE shop JUMP approvethe site plan Or appicadon EU saw SHALL NOT Eve SE lm PERCENT O rtN EAMPAcm OF THE EU saw ON EC 705 e®n be proved up on approval MHEENNane Agaes. ELEC. 3 LINE DIAG. Rohecured PhCTra l Mlwa require �PVS Neo SPUN ITTIRE meter and AC Disconnect l5 e ve1lori black anering MOWIESPECIFICATIONS Txnazolar3AT5MO[OFM. 4R VIX DESIGN LOCATION AND TOMPEAANRES N4%IMJMINPUTVOLTAGE 4RVOC W OZ RATED POWFAISTCI 320w TEhPEMTURE DATA SOURCE ASHRKZf6AVG.UNSH h9 NgW1EVOC 10.3VOC MSTDI STAIN TAM 210 GOOD o NgW1E VNY 33.4110[ CITY SAN 12Cu. Wneat MORe No"E"I'M 9DWAK WTAmfIf STATION VNSESEQ2(MOXIOCOMNNERSOX) DENVWCENTENNIA "B'Do"SC 10.3 A OC 24oNU ASINAFEMRftaE LOWDEMP�Yj ACPIOTOVOUTCIAMMENNR%INS NECDIJ. 33 VMDo"UMON Paxvc WCu ASHUEMAVG.HIAUlENW' 24032 Qll% 33 VNYCORREMON B%%rc TOTALVRISE 269 2A2M TON SELSERATNG MAX 47-611 SVS}FM EIECIRICALSPECIFlGTIOHS DRI QRS! CIR3 CERA IMS CIR6 ADI. ANDI VOC@' ASNRAEIOWTFNP 453VOC MOUNIMMACPOWER 2W VAAC PWTOVOLTAICACDISCONNEROU1PUE RL NEC69159 wxiwMKCLMRETT 1:OAK ADI. NNDOMSB NO ASHME2%AVG.HIGHir }86VOC 2LOAK MAYIMJMpCPORATNGFORA[MOWLE MAX MIOLOINVERTER SPECIFICATIONS EnDhne DONurrolmi POWERPOIWT MNG(MPPT)MWMA% 22- 4R VIX 31 35M1 N4%IMJMINPUTVOLTAGE 4RVOC W OZ MA%IMJMDCLtlRTCIRCURCIMROIT ]SAO[ 6RJNOC M9%IMJMUSAMMMINPUTPOWER MUD MSTDI NN%IMIMOUTPUTCURRENT TAM 210 NUN9EROF M]DNFS PER NPPT DCPLIBIODATNGPERCIRQ11i15TC1 OTALMNGORAFIMPER STCRATINGOF APoNY ACCIEFURENT MO1(.CUMEM(IMP%12q O FOOLARRGiiRATINGPflIQRCLR NW%.COMARRAVACCMREM(IW) MaX.ARPAVACPOWEA 30 32W 31 35M1 U N W W OZ 3STUDY F5 6RJNOC ]ILO 1u1175 l 110 N MSTDI BOND. MISEV 210 SMONAC A[DVFRNRRFMP�iECTON LDA O U N W W OZ MAXIMJMDINpNTppIVFR GO IN ACISOLTAGE RISE CALCULATIONS MSTDI BOND. MISEV VENDY%MDSE IQ7-ll CECWUGNTEDEFFICIENLY 47% VNSESECIACROTOMENO SAN 12Cu. ILA 241M (i VNSESEQ2(MOXIOCOMNNERSOX) 15 UOR 66/ 24oNU 0.221E ACPIOTOVOUTCIAMMENNR%INS NECDIJ. VIUSESEC3COhHINERROXII)FOl 5 WCu 037 24032 Qll% NOMNALOPERATNGACWITAGE 2ROVAC TOTALVRISE 269 2A2M Lll% NONWALOPERATNGACEREQUENCY 47-611 MOUNIMMACPOWER 2W VAAC PWTOVOLTAICACDISCONNEROU1PUE RL NEC69159 wxiwMKCLMRETT 1:OAK KOIIIPIRCDRXfM 2LOAK MAYIMJMpCPORATNGFORA[MOWLE MAX NOMNALKVOLTAGE NOVK JULY [NEC 880471 AND [NEC 2GY G1 THROUGH [NGROUNDING HORS EC 250 601 SHALL BE PROVIDED PER NEC PROTECTED ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERMCE ENTRANCE IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE OR IS ONLY METALLIC WATER PIPING A SUPPLEMENTAL GROUNDING ELECTRODE FULL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD JULY ACORN CLAMP 2 THE GROUNDING ELECTRODE CONDUCTOR SHALL BE FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER)IF SMALLER THAN #6 ALLAT COPPER CURB RE R NEC 250 RUN THE GROUNDING ELECTRODE CONDUCTOR FULL BE ER EXCEPT[NEOsacORPuces OR JOINTS AT BUSBARS PUFFIN LISTED EQUIPMENT P3 GROUNDING ELECTRODE S SHALL BE NO LESS THAN #8 ALLAT AND NO GREATER THAN #6 ALLAT COPPE R AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM 4 PV SYSTEM SYALJBE GROUNDED IN ACCORDANCE TO[NEC 250211, [NEC TABLE 250 C Iz11, ANO ALL METAL PARTS OR MODULE FRAMES NG TO [NEC 481 MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE To [NEC6 THE GROUNDING CONNECTION TO A MODULE STAFF BE ARRANGED SUCH THATTHE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTORTO MOTHER MODULE7 EACH MODULE FULL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTSIDENTIFIED IN THE MANUFACTURER S INSTALLATION INSTRUCTIONS8 ENCLOSURES SYALJBE PROPERLY PREPARED JULY REMOVAL OF PANTAINISHAS APPROPRIATE WHEN GROUNDING EQUIPMENT JULY TERMINATIONGROUNDING LUGS9 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE ANDGROUNDING DEMSES EXPOSED TO THE ELF MENTS SHALL BE RATED FOR DIRECT BURIAL10 GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER SOLD OR STRANDED AND PAGE WHEN EXPOSED 0451To [NEC 11 EQUIPMENT E T EXPOSED TO DAMAGE (.cAwo SHALL BE USED WHEN EXT GREG TO �E) ry 12 GROUNDING AND BONDING CONDUCTORS IF INSULATED ,S ALL BE COLOR CODED GREEN (OR MARKED GREEN IF #4 ALLAT OR LARD 13 ALL CONDUIT BETWEEN THE UTILITY AT R)POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS H ENDS 14 SYSTEM GEC SPEED ACCORDING TO [NEC 690AO�[NEC TABLE ROGER], Dc SYSTEM GEC SPEED ACCORDING To [NE cu0 OR;1, MINIMUM pmvro WHEN NSULATED #6AWWMEN EXPOSED TO 15 EXPOSED NONCURRENT CARRYING METAL PARTS OF MODULE FRAMES EQUIPMENTS AND CONDUCTOR ENCLOSURES SHALL BE OUND ED A CORDMCEWTHRO013AORRO013bYNREGA DLE4oFmLT GEN WORD A CONDUIT HORS 1 ALL CONDUIT SIZES AND TAKES SHALL BE TITLE D FOR ITS PURPOSE AND APPROVED FOR THE SITE POP UCATIONS 2 BOLTED TION REQUIRED IN DC DISCONNECTS ON THE wrvITE GROUNDED CONDUCTOR NSE POLARIS BLOCK OR NEUTRAL BAT) REDUCING WASHERS DISACROCARD ABOVE LIVE PARTS ME PERS HUBS RECOMMENDED 4 TV RESISTANT CABLE IESOT ZIP TIES'( USED FOR PERMANENT CURE MANAGEMENT ACCORDANCEOFF THE ROOF SURFACE IN a'BACEN 3004 5 SOLADECK JUNCTION BOXES MOUNTED FLUSH WROOF SURFACE TO BE USED FOR CURB MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS 6 ALL PV CABLES AND FORERUN CURES BE TAKE USE 2 AND SINGLECONDUCTOR CABLE LISTED AND IDENTIFIED AS PVWRE TAKE TO ED OR EQUIVALENT ROUTED TO SPECIFIED ACCORDING TO [NEC R MULTIPLE CONDUCTORS 8 ALL PV o 81 a CONDUCTORS orvoui EXPOSED TO SMUG ALL To c rvTSHALL eel AT LEAST EGG ABOVE THE ROOF SURFACE AND RE RATED ACCORDING To NEC TABLE 31015 OHYMP, NEC TABLE 3101 GBAP) )A NEC 3101 B@}3(O1. 9 EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE 2 90-C RATED WE T AND TV RESISTANT AND UL LISTED RATED FOR 600V TV RATED SPIRAL WRAP SHALL BE USED TO PROTECT CURB FROM SHARP E DOES 10 PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED TUHI CAN 2 INSULATED 90-C RATED JUST AND TV RESISTANT RATED FOR 600V 11 4 CURB DELTA CONNECTED SYSTEMS HART THE PHASE JULY THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS 12 ALL SOURCE CIRCUITS SHALL HART INDIVIDUAL SOURCE CIRCUIT PROTECTION 13 VOLTAGE DROP LIMITED TO 2% FOR DO CIRCUITS AND 3% FOR AT CIRCUITS 14 NEGATIVE FOLLOWS DC GROUNDED ERF(MR�oREaNEn REDovD OR Aw0oonVE GY(ORM�GRED 15 POSITIVE GROUNDED SYSTEMS DO CONDUCTORS COLOR CODED' DO POSITIVE GREY (OR MARKED GRE o, OC NEGATIVEBLACKCOR MARKED BLACK) 16 AT CONDUCTORS F4AWG COLOR DED OR MARKED PHASE A OR Ll BLACK A NAME B OR L2 RED A NAME C OR L� BLUE NEUTRAL ACTITLEGRAY � USE 2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWIFT CAN 2 AND MAY BE USED INSIDE �� USE 2 IS AVAILABLE AS UVACTITE 17 RIGID CONDUIT IF INSTALLED, DODGE NIPPLES) MUST HARE APuu BUSHING To MOLE CT CURES 18 IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT FULL BE EITHER EMT PRO OR GO CABLE IF DO CURRENT MP LUNG CITY NEC BSO.), NEC 250 11 NOT 0) DISCONNECTING MEANS SHALLCOMPLvwnH 690 13 AND BSD 15 19 CONDUIT ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE TH NEC 230 RAN AND SECURED No GREATER THAN s DRAFT PER NEC 330300) BLUE RAVEN 4A NRESEARACHODAY BUILDING J OPERA U184097 800 377 AM POPPY BLUERPRENSOLAR COM CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF EUROPE EXCEPT BLUERPRENSOLAR NOR SHALL IT BE DISCLOSED IN MOLE OR IN PACT TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN CORNEA HIGH PULL THE SALE ROD USE OF THE RESPECTIVE EQUIPMENT OMTHOUTTHE CHAPTER PERNISSION OF NNABCEPA CERTIFIED PV INSTALLATION PROFESSIONAL Won Owney CONTRACTOR. HRS FIELD OPS 385 498 6700 tlYtl G Q 2 s O U N W W OZ o FLY W H m o Q OF W > 0 o rwu ee Kira Carey April ]H,2020 s xuu nW969A SSE ELEQ CALCS. ELECTRIC SMOCK HAZARD TERMNALS ON THE LINE AND LOAD S'CES MAYBE ENERGIZED ._ _ IN TME OPEN PDSMON . MAXIMUM VOLTAGE • VDC MAX GLRCUR CURRENT AMPS NATEDACOIIPUTCEII A KpILN4CPERATN:ACYCLUGE V VI►ARNIN D'JA. P0%RFR SUPPI Y SOURCES. UTILITY GRID AND PV SOL+N ELECTRIC SYSTEM INVERTER OUTPUT CONNECTION 00 NOT RELOCATE THIS OVERCURRENT DEVICE TRIS EOUIPAENT FTD SY MULTRE SOURCES. TOTAL RATING R ALL WERGURRENT DEVICES, EXCLUDING LMN S14MYO'/ERCURRENT DEJICE SHAME AMPACOY OFE BU BUSBARAR PHOTOVOLTAIC SYSTEM CONNECTED PV AC DISCONNECT LABEL FORPV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DIACONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B), NEC 705 221 wBEA2 IN EACHDCHEDISCONNECTING MEAN S, wcwDING THE c DISCONNECT AT THE INVERTER [NEC 690 53, NEC 690.13(8)[ BEL3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 69054, N EC 690.13 (B) FUTTE IFINALLTHI NECTING L THELOADSIDE, INSTALL THIS BOTH ANYWHERE THAT Is POWERED SYS BOTH THE MAIN SERVICE THE SOLAR PV SYSTEM. THE MAIN SERVICE PANEL [NECSUBPANELS [NE c 705.12(epa)1 wBEL5 PLACED ADJACENT TO THE BACKFEDBREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)1 LABEL6 (ONLY IF 3 OR MORE SUPPLY SOURCES TO BUSBAR) SIGN AALOAD CENTER IFIL CONTAININS 3ORMORE POWER SOURCES. [NEC 705.12(e)(2p3pgl LABEL IO SIGN LOCATED AT RAPID SHUT DOWN DI SCONNECT SWITCH [NEC 69056(C)(3)1. L BEL I2 PLACARD TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY LABEL 13 PLACARD TO BE PLACED AT AC DISCONNECT PER XCEL ENERGY. SOLAR PV SYSTEM EQUIPPED NAT I RAPID SHUTDOW NMRNLRMIRMI /� vrTaomxro ouroriR+wunrM uOMPXF •awxallo MTrt AGMY LABELING NOTES. 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STAN OARO 190ID.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOTBE HANDWRITTEN [NEC 110211 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND REFLECTIVE AND PERMANENTLY AFFIXED IFC 605.11.1.11 RAPID SHUTDOWN TEST NOT REQUIRED LABEL AT DIRECT CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS SPACED AT MAXIMUM IDFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690 31(G)(3&4)I LABEL FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OFALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOTAL THE SAME LOCATION. [NEC 69056(C)(1)(A)l LABEL 9 FOR PV SYSTEMS THAT ONLY SIT UT DOWN CONDUCTORS LEAVING TH E ARRAY. SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALLINDICATE THE LOCATION OF ALIDENTIFIED RAPID SHUTDOWN S WITCHES IF NOT AT THE SAME LOCATION. [NEC 69056(C)(1)(B)l ABEA 11 SIGN LOCATED AT ACO C COMBONFR OX FOR ALL MICROIINVERTER/ACIN ULBE INSTALLS (CAPPLICABLE). LABELING DIAGRAM FOR MICRO INV.'. MAN SERNCE PANEL 19YBIlOMIIIIOYB6NlD smanlaM WWN•IMIRpI uruno•ralRsrLomm n BLUE RAVEN LABEL 15 1403 N RESEARCH WAY BUILDING PERMANENT DIRECTORY TO BE LOCATED AT OREM, UT84097 MAIN SERVICE EQUIPMENT LOCATION IF ALL ELECTRICAL POWER SOURCE DISCONNECTING 806377-0480 M EAN A(S OLAR ARRAY RAPT D SH U TDOWN WWW BLU ERAVEN SOLAR COM SWITCH) ARE GROUPED AND IN LINE OF SITE OF INTERCONNECTION AC DISCONNECT MAIN SERVICE DISCONNECTING MEANS. CONFIDENTIAL-THEINFORMATION IN EC 69656(C) & NEC 705.101. HEREIN CONTAINED SHALLNOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT LABEL 16 BLUE RAVEN SOLAR NOR SHALLIT PERMANENT DIRECTORY TO BE LOCATED AT BE DISCLOSED IN WHOLE OR IN SOLAR ARRAY RAPID SHUTDOWN SWITCH PART TO OTHERS OUTSIDE DENOTING THE LOCATION OF THE SERVICE RECIPIENTS ORGANIZATION, EQUIPMENT LOCATION F SOLAR ARRAY RAPID EXCEPT IN CONNEC TION WITH THE O SALE AND USE OF THE RESPECTIVE SHUT DOWN DISCONNECT SWITCH IS NOT EQUIPMENT WITHOUT THE GROUPED AND WITHIN LINE OF SITE OF MAIN WRITTEN PERMISSION OF SERVICE DISCONNECTING MEANS. O IF BREAKERUSEDO BLUERAVENSOLAR LLL. [NEC 705.101 `EDEA" NABCEP ENT DIRECTORY BE LOCATORAT MAIN 15 OR 1] SERVIC IPMENT DENOTING AOCAnoN CERTIFIED HUTDOYSTE OFTHEPVR SHUTDOWN SYSTEM OFTHEPV PV INSTALLATION TING MEANST RAPID DISCODOWN SHUT DOWN IS SWITCH Is NOT O CO Y N PROFESSIONAL THNECTSWITCH GROUPED ANo OF EMAIN AND SERVICE DISCONNECTING MEANS ECTINCMEANs.[NECE705 10 11, sM719'015 69056ISCONN NEC 690 56(C)(i) # P4011]19-015866 CONTRACTOR: BRS FIELD OPS IF BREAKER USE 385.498.6700 ® EXISTING SUB PANEL (IF WHERE POINT F PVCOMBINER INTERCONNECTION AC DISCONNECT IF USED TO COMBINE AC JUNCTION BOX 12 13 IS MADE) (IF RED /INSTALLED) PVOUTPUT CIRCUITS OR AC COMBINER BOX O O O IF BREAKERUSEDO 1O O�E] 15 OR 1] (D-0 16 O CO Y N OR PLACARD O IF BREAKER USE Z' (0PLY IFPV 0 t+ O INTERCONNECTION� Q y. O N CONSISTS OF LOM U SIDE BREAKER) N (� 00 i m 0 W 0 a LABELING DIAGRAM FOR STRING INV /DC OWI MIZER NV.' w Lu MAIN SERVICE PANEL Z a E (n INVERTER (S)QY Q N 1(IF O EXISTING SUB PANEL PV COMBINER SUBPANEL- W OO XINTERCONNECTION WHERE POINT OF AC DISCONNECT IF USED TO COMBINE () (O 12 &® IAMAD E) (DREG /INSTALLED) RVOUTPUTORCUITS 00 Q m 0 IF BREAKER USED 0 W DRPNING Kira Carey ®DR� �3 &® 16 13 15OR( ORUARD IF BREAKER USED Q3 JUNCTION DOX OR COMBINER eox E April 28, 2020 IFPV(o (D dECT eEe (ONLY PLY IF PV 16 INTERCONNECT o CO NSI STS OF LOAF INTERCONNECTION CONSISTS OF LOM 11 ® SIDE BREAKER) SI BE BREAKER) (D73079694 INTEGRATED DC DISCONNECT ITEETry LABELS 'ELECTRICAL DIAGRAMS SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PVR OF 3 LINE DIAGRAM. PVR LINE DIAGRAM TO REFLECT ACTUAL POE NUMBERON REPRESENTATION OF PROPOSED SCOPE OF WORK. PV8 0 BOB BI Enp eMic,an even gegen AMEAICPS Enphase IQ 7 and IQ 7+ Microinverters A To Team m(Ye aooN Enphase ofremgs, vias e r phaae.c um M hi0htnower ci zmen end+eady Ephese 10 ) Mkro and Enphase 10 N IN dramellealN siTPufy the n9elNtlon pro ums while achleai,q the highest system effia lmy. Pan ofthe Ephaze 10 System. the IO ) and IQ )+Miwinveners imeg,we Now the Enphase IQ Envoy'. Enphsa a Q Baum', and the Enphase Enlighten' monaaip and aplyziz mkware. 105e2ie i Micminverten mats Ne Mitutty standards a& forts M menous generations and wdergo overa mnlml bourn of pnwagn testing Borabling EwARSOe to Pmvidean i,Murtryleadip wenenryofupm2syeen. Earybl,utall l"f,xai Jnentlalnple MentralmIwaFirrprmed 4glnn,wmrcnhriq 1ladlx:tlre and Reliable ryAnmermnyn pMeeeao dlren�eE.mmu., 4vetlu,n nilimbuadnneg Iy.Maewa-w,w.rcex�aa� ulurcd Snap and Reedy cn,wsnmahw.e...egd„�pLn.aweaa tng.m me.d.ay�,eweaee vAh wanes m,eepma,e d,agiy ,nnimmns Cuff Wes GO AWARD! A.B.17411 iGOB) n.02. senas,epase open nyem eats. ,9,, ENPHASE. BLUE RAVEN ' I RESEARCH WAY 1N01 Enphase IQ 7 and IQ]+Micraimerters ORxs. UI 800 377 OWN WOOD BLUERSAFEENSOLARE COM nmm Ignwza2I umwaa.n.x.aa ^^^,a4wammaewwip.' mmuxsmNrzau�vmwuxCONFIDENTIAL n.HEREIN THE INFORMATION ..a Ran ON: ad w, 48 A, v CONTAINED SHALL NOT BE Prsk PHIL45V USED FOR THE BENEFIT OF wµx ov vnvnnv,21. v v DISCLOSED IN WHOLE OR IN PACT MV, ME 1I dirwoae,n, follow m) ISO TO OTHERS OUTSIDE RECIPIENTS all, PC PRO, 11 11 ORGANIZATION AGENT IN CONNECTION WITH THE SAFE AMID 0 USE OF THE CONNECTOR nv anay.mM1O."MI Qumm� a addlicarral I sae p,denim,rymre mFAANO INUMBoh E WRITTEN PROGRAMS OF HAVEN AFTER TO OBJETINVIF BASIN pC, mora m.MEMO ..n., aMINE w or smn, VOL ea 3°0 vO yr NABCEP N"wii llutowu�•rc. MORE 211 NIMBI �B2w.aoa.1 CERTIFIED w ,m=m.e., In ,�aM, 22.a .1 PV IN STALLATI ON m lle low EVIL firmu"N"y "N. eels 47-M Our PROFESSIONAL slMn AM POLAR IV ON Arera a+)arenam,u•m aha OV.d ,Raoxvk, 23QlavNcl ,I leaevpm CONTRACTORACAMUbm ONNEARGOkA,M,,OGGIAGPINNI III OA A ERS FIELD OPS 10 2 Plivauld, h2@2wv 2h@aa2v 385. A98. ElEE ICw,Mtl,rsY @awvp g� v 9711, 91 MENSIVINICALIMANNA AVOI HEREIN,, ,91 40"EM"NUM P ANANNIONABI ournackar Yp Ip24AV244 apRLY4)b2L% a1C< NO MpamM NO YTX'MIMN VO IPttL2lYw CPM' MAR w,waUY aiaagw.rzawl 1411 Wo NA C' NUMMOVIBOHN ANOMPAR5 IV MI ARM AM 4 NO Un .K Mrs ONE 1. MCA d.r RAN MEN BOB IMI(WMMy II(a bewg mu zesie.) III lz Ware m .Iwmnvn.,wwo mar wanme m MoRm, ON EMIII Clues ceaam.c,wm, III wpm.na.rcicm. Ern,waw MMA.w txeerc.amw.,mep x«mow a.IamMmMereewmu..,. ..2nx..eaexM,. pem a.nwm... elnuLi.w...m.Inea,nr wmwN ammNVw pee.n.nxxw.a.pwm �w eunxnnce SAIWI-p>: o...,:amts a. IeiaaaaarL.. a. CANICILEC2112NO HEATED ,mnx,u 91�f mWhmmwLWb x L.nn,n.vn wm msm,GAMEN .acn n. x..m m,...vn.vm.en neer alarm AN AT NAME TolmmI eaW° Enpheseaaerhg Ashwphs.mn QENPHASE SPEC SHEET I BE rcnI rc.a. SS EvPhaee N BN ..IF ny Enphase IQ Combiner 3 (X-IQ-AMl-2d0-3) U� LISTER To learn more abwl Enphase onennpe, vlsn emdraae.mn The Enphase IO combiner a' with Ewnaee 10 Envoy" consenIidtes lmemonnedlon epuipmenbFair a single amdeure and streamllnes W and mange immwhitarw by SUOvitling a consgerd, pre wined solution for reSdential applications. It offers up to four z wle mput circmts and Earon Be aeries bulbar assembly. smart mwe, rp Emgymmmumrarim Sprint nnAknnwrniteepppmaW IFF 'Porti rmmYWemilebbrprg0 Sr m Simple Nrae era mhme mdm warp Wt he<epa=lae=mAppeal Up A PAT Simple Near ISCAft UP u wnmurw angor InM�) nrwlu VAC Fellable mea Ed UP rroe SIR anappire C',' ENPHASE. Enphase lQ Combiner3 MODEL NUMBER IQ emsrcex X BEHAVIOUR.ia OEmp' pug nae h=web engem I..gr .I snares uti. D C12 BE 11 0 ACCESSORIES A REPLACEMENT PARTS ino: cardwan mr CGUPUARCE entlee aa(oPAN eLYmeutMlvneeenLrrtmWemvnFdmp6n (x Auremeymea ar(xs 15 Y. dan piety inkrunnuumn. Vn^ohlempeuS C.A., unim, Pu meq em mucin xYmx COLLMONTANAl Vae••que+nrirvawplN adrxunxum•yuullWx•mwNrn•unnmlmuul amp a. 47 END •r�naRANryfium�rairr CT 2ONGSPLIT my Or-xs) Burned dreard, Avmrr• SHEET 810, axx15, B0N. Ml WelUSE,�mtl eP]W Cl brunt. CUBAN al 2p ,INOEarn aw,a FDA, 4rmon 15 x pars l,3ppkxeR,4rmIN .da �' Irl UTBwpkv mu pmerm as uwxm n ro[ pere 36ew (n DEFEAT)mrnvdmx " ENV CUBAN ip Enwx Ankin ae hrve(PE)lo- Connote 3 ELECTRICAL SPIRCUSCADITONNES Mft SE'repicaul 12(1 put AD ITT a= mama le,n=mmrpm were) USAw rneq(anlpnlNSA na . .en o-emapet n nraxnoe Eeronene.ne.ornnhnreao..r...rrm(mlmn•.emb Nmremeel =neo -n Max circuit a CHEAP e P nOwml) w'i u mvmm •., .oaawr.a�r.waxn.neamaag MACHANICALBAl wmvaur Her Onne snuE•ass 1 NupFre 21 DEC pays on wm mwrmebnnaul Unit p•rxvu•m• PC. C Ed Aft.t Fou 1, 11a•Fl ("We NI I AAAA1Ar DUN NASA erld nma nxnmrelrnmp0== xd rq Sir 11 It I awn waeaurs exkep. orRAVEGRoppeconduct • maranpw=ia evtwe ." r „mnrxepmperp•rr'm INTERNET CONNECTION OPTIONS To learn E o ffM,W wanplan. ...m ,.<rs.ar„ ,r�i IF B,,.e.a.<. �,, ENPHASE. BLUE RAVEN DAYS N RESEARCH WAY BUILDING J FARM Ul CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF BEYOND SWEET BLUE Rl SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PACT TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION SWEET IN CONNECTION WITH THE SAFE AND USE OF THE RESPECTICT EQUIPMENT WTHOLITTHE WRITTEN PERVAISSION OF BLUE HAVEN SOLAR TO PROFESSIONAL V011rcolb N Pme CONTRACTOR ERE FIELD OPS 385 498 6700 SS SHEET Call re c'ar el WE III old. Nu mrNaeel snares rage wuoosuu NAVE) n cuwaur LIGNI rrtaelum NwejnoEu CGUPUARCE cuwomn. EaTmrmr (Apil 2 f 1071 47 END •r�naRANryfium�rairr 05w midcm cxnpumunpm UL oeapro To learn E o ffM,W wanplan. ...m ,.<rs.ar„ ,r�i IF B,,.e.a.<. �,, ENPHASE. BLUE RAVEN DAYS N RESEARCH WAY BUILDING J FARM Ul CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF BEYOND SWEET BLUE Rl SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PACT TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION SWEET IN CONNECTION WITH THE SAFE AND USE OF THE RESPECTICT EQUIPMENT WTHOLITTHE WRITTEN PERVAISSION OF BLUE HAVEN SOLAR TO PROFESSIONAL V011rcolb N Pme CONTRACTOR ERE FIELD OPS 385 498 6700 SS SHEET Mono Multi Solutions THE Residential Module MULTI-BUSBAR120 HALF -CELL BOB MODULE 120 -Cell 310-335W POWEROUTPUT RANGE 19.7% MAXIMUM EFFICIENCY 0^ +5W POSITIVE POWERTOLERANCE Founded 1997 Una Soared, ,Ws Noting tondsolution With I povideettmund treelry°,eeFind S°�Gabl each LEGAL and calOgrour innovatwas Sun poducocidthebackingofunadastmor Appel HiLaSolaroWdIerbulb Weamcommittedtobuildingstmegr mutually beneyvalcolabor,torn, am mi decades, distributors and other Barney in driving such eneratoyether Comprehensive Products and System Certificates em eneynern IS014064 a�ansEmer�rem rnnd iery CE DDD Trinasolar High ed powerou[put • Reduce EMS cost with M1lgM1 power bin and module efficiency . New cel l String layout OFF spot -box mmtl°n retluceS the energy lois caused by'mter-Few shading Lower resistance of halfcutcells and increased MBB (Multi BusbaQ reflectance ensure higherpower High energy generation, low LCOE Excellent 3N pamvau RteJ AM antll owugbt Pertormancewlth cell pmcesSandmOdulematehalopomleaoon LOwpmaxtemp mefflclent(-0.361)1nveasesenergypmducd On Better anti -sbatlmg performance On l ower opera ting tem pevatore POutstanding visual appearance, easy to install Deslgoed for superior rooftop aesthetics • Thimerwlreigive a eye ctcthingOfI black IFEE -Safe and easy P to transport handle, and Install Eertlfletl to perform In highly challenging envlronmem High PID Leslaance through ceu process and module material mntml ReSlstant to saltatld,sand,and ammonia • McF30ln- house tests (UV,TC HE etc) • @Nfled to 5400 Pa positive load and 2400 Pa negative load PERFORMANCE WARRANTY 10 Year ProduaG brander z UWA I• Tema®m YSB 10 1� SO 25 Residential Module Trinasolar MULTVBUSBAR 120HALF-CELL BOB MODULE ELECTRICAL DATA STIC) PRIDUCTE mG"re",."evol"up 1-COGM) Operational Am each L°R ° MGt Pro M 9906Mn„N. 6laa. OE,� MONOCRVSTALLINE MODULE Gas 1OOOV Uquy GRACE OFFER. 61aa 310-335W POWEROUTPUT RANGE 19.7% MAXIMUM EFFICIENCY 0^ +5W POSITIVE POWERTOLERANCE Founded 1997 Una Soared, ,Ws Noting tondsolution With I povideettmund treelry°,eeFind S°�Gabl each LEGAL and calOgrour innovatwas Sun poducocidthebackingofunadastmor Appel HiLaSolaroWdIerbulb Weamcommittedtobuildingstmegr mutually beneyvalcolabor,torn, am mi decades, distributors and other Barney in driving such eneratoyether Comprehensive Products and System Certificates em eneynern IS014064 a�ansEmer�rem rnnd iery CE DDD Trinasolar High ed powerou[put • Reduce EMS cost with M1lgM1 power bin and module efficiency . New cel l String layout OFF spot -box mmtl°n retluceS the energy lois caused by'mter-Few shading Lower resistance of halfcutcells and increased MBB (Multi BusbaQ reflectance ensure higherpower High energy generation, low LCOE Excellent 3N pamvau RteJ AM antll owugbt Pertormancewlth cell pmcesSandmOdulematehalopomleaoon LOwpmaxtemp mefflclent(-0.361)1nveasesenergypmducd On Better anti -sbatlmg performance On l ower opera ting tem pevatore POutstanding visual appearance, easy to install Deslgoed for superior rooftop aesthetics • Thimerwlreigive a eye ctcthingOfI black IFEE -Safe and easy P to transport handle, and Install Eertlfletl to perform In highly challenging envlronmem High PID Leslaance through ceu process and module material mntml ReSlstant to saltatld,sand,and ammonia • McF30ln- house tests (UV,TC HE etc) • @Nfled to 5400 Pa positive load and 2400 Pa negative load PERFORMANCE WARRANTY 10 Year ProduaG brander z UWA I• Tema®m YSB 10 1� SO 25 Residential Module Trinasolar MULTVBUSBAR 120HALF-CELL BOB MODULE ELECTRICAL DATA STIC) MAXIMUM RATIN GS mG"re",."evol"up 1-COGM) Operational Am each c Pe1kPUyWaG,Fm,g,p' Pro GI GDO G25 SEE Gas 1OOOV Uquy nmn,nROrwWPw01�mm Sea, w rapno�conneareby aa■ WARRANTY PACKAGING tONnGNRATION ProductCOMBAT ma,ann nter 25 Fearmy � Modules per 40 container 790 pieces iT kp�rrra� Ope�7,=�agl GO 9 401 40C 404 406 40 7 SIMOCUbutCurnent Ed B) 10 Ed 1012 10 20 10GO 1040 1050 Module Efficiency U ni 19 2 195 199 191 194 19 7 SS pdur Scroll W, ELECTRICAL DATA WOOL) Maunum cover Am Wo Ede EGG 242 246 250 254 Shot Circuit Current Ed B) 909 915 9 22 sea Sea 946 MECTAN PAL DATA ceorCeIg oren sio 120cell, lallne 1699.1004 xas run (66 el SP` x169 n i 19Fad (41216) wa mInches)mldInches)m es) High TmnsmGso2ARareetempermClass6 dark G5 run IF GO lnmepAmeeeeAmmlmurl IP69 typed Grat A IPOMImm rssvuzzinches) Andeape A 1200 TWO 1200 min (472V4r24 Inches) BLUE RAVEN 1403 N RESE spot WAY BUILDING J OREM UT 84097 800 3 CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHFULMOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RFAVEN SOLFING NOR SHALL IT BE DISCLOSED INWHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN CONNECTIONWITH THE SAFE AND VE EQUIPMENT WITHOUT THE WRITTEN PERMISSION OF BLUE nNAB CEP PCERTIFIED PV INSTALLATION PROFESSIONAL Gurney A PV 01171 NOT 5866 CONTRACTOR BRSFIELD OPS 3854986700 TEMPERATURE RATIN GS MAXIMUM RATIN GS mG"re",."evol"up 1-COGM) Operational Am each c Tempe Coefroemor E6AWC Maemum ry,,:e. a3A Uw UEUrci Temi Coeff 026AWC 1OOOV Uquy nmn,nROrwWPw01�mm Sea, w rapno�conneareby aa■ WARRANTY PACKAGING tONnGNRATION ProductCOMBAT ma,ann nter 25 Fearmy � Modules per 40 container 790 pieces iT kp�rrra� peffir�P� CAUTION READSALTY AND INSTALLATION STH OPTIONS enDRE USING THE PRODUCTSHEET _ mnAll rights rmervmSRA➢am l inclmm m this is Johl g9 SJUD t Wool wrtneul m® SPEC SHEET venal numberl:��MrvultaNgE199 ardwri�nasoncom AG ENUMeER �9IN SS m U 0 rd [412Zmm] 1.63in t183.97ni Z.24in t266.Z0mmI 050in R �T t71.09mi EGON F ITEM NO. PART NUMBER DESCRIPTION Qtt. Weight (t&S): JB -I Body at Z TOY POLYCARBONATE WITH UP wanw.ea Iarprodocts.com TECHNOLOGY INHIBITORS 2 JB -ILidw/Gasket POLYCARBONATE WITH OV 1 RE B DWS NO JB -1 INHIBITORS 1032 x 1" Phillips 3 pan head bolt #8 x 1-1/J"Phillips pan head screw Torque Specification: 15-201 FUn Certifications: ULstanaam 1741, NEMA3R Weight (t&S): 13 Its T EZ Solar (24.31mm1 SLID, InUSA RUT Phone (385)202-4150 wanw.ea Iarprodocts.com PM a UP EZ SOLAR "�" "' RE B DWS NO JB -1 I 0 BLUE RAVEN 1403 N RES EFFERCH CRY BUILD NO J 800 377 pan BLUEREASONSOLESS PON CONFIDENJOH THE INFORMATION HEREIN CONFIRMED SHRELL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAMEN SOLAR NOR SHEET IT BE DISCLOSED IN WHOLE OR IN NOT TO OTHERS OUTSIDE RECIPIENTS ORANDECTION EXCEPT IN CONNECTION WITH THE ABLE FIND USE OF THE RESPECTICE EQUIPMENT NUTHOUTTHE WRITTEN PERMISSION OF BLUE RAVEN SOLAR TO PROFESSIONAL V01171EONI R Smey N Pe CONTRACTOR RES FIELD ORB 385 498 6700 apo SPEC SHEET SS" . a0. 4 3 2 1 BLUE RAVEN [17 .73 HIT] 6.721n 4A N RES BEACH COPY BUILDING J [19.81 MIT] [55.89mm] FARM III FT0J81n 2.201n 800 377 DA DOWN BLUERFASANSOLAR COM CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE [5J.94mm] USED FOR THE BENEFIT OFANYONE EXCEPT BLUE BARAN 2281n BOTH NOR SHELF IT BE DISCLOSED IN WHOLE OR IN PACT TO OTHERS OUTSIDE RECIPIENTS B A [12.42mm] BCONNECTION WITH THE SAFE ANDUSE OF THE RESPECTINE ORGANIZATION EXCEPT IN 6.60mm �` V955 0.491n [ 0.261n ] SOFR0T3bnj �a'�o>a aP,:HAVENB"0��IPMENT o9PC ,'CFa,UE NABCEP i CERTIFIED :[15amm] 0v INSTAunnoN A04.80mm]251n ® A ® PROFESSIONAL 12.001n [50.80mm] XPNTRABo OR 200In [V6.91in CONTRACTOR 6.91 n IRS FIELD 6 008 ' mm] 385 498 bToo ® ® 0.381n [5.55mm] 0.221n ® ® SECTION AA SCALE 1 :1 Indent [57.94mm] L A [266.70mm] 2.281n A 10.501n EZ SOLAR 4 3 �.'�...�AIR SIR 'o 11 A.w e.w .m.�FORMm.,.wa am cba _,e�..���, �. g jg_] ,. Fa- gw wE,x, t3 SEFNADE SPEC SHEET a..ss. .IMs0. BLUE RAVEN 4 3 2 1 1403 N RES BUNCH WAY BUILDING ONES LUANNE 800 377 AN HEREIN COMPARED SHPILL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE Ri SOLER NOR SHELF IT BE OUTSIDEINSIDE DISCLOSED IN WHOLE OR IN ACTTO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN CONNECTION WITH THE SAFE AND USE OF THE RESPECTIGGE SECTION A A qEQUIPMENT OMPTHOUTTHE B sou=1:2 � B WRITTEN—FARM SOLER TO NABCEP CERTIFIED PV IN STAUATI ON PROFESSIONAL CONTRACTOR ERE FIELD OPE 385.498. E7EE [198.3Jmm] 7B1in [3.I8mmp .13in LID OVERHANG Af [2223mm] �I639Jmm� 7.24 in .M in A A FINGM RUN DRELDFRAPE IN GREEN ANC A' GRALLF 'END F EZ SOLARCOPPER na,, NF SIZE SEA NO REV B J13-1 WHET SUPER OF3 4 3 2 SERFNAME SPEC SHEET a..ss ne�so Dx. ■n ; FRAMEno SFM IL Star Washer Is Single Use only TERMINALTORQUE. InstaU conductor and torque to the fagowl ng: 4-6AWG: 3Slmlbs 6AWG: 25 In -Itis 1014 AWG: 20In-lbs SYSTEM BONDING & GROUNDING I ■ INSTALLATION GUIDE#' PAGE #4 TERMINALTORQUE. In tAU Conductor and torque to the !allowing: 4-14 AWG: 35in-Ih WEEBLUG Single Use Only TMMINALTORQU� Install Conductor and torque to the following: 6-14 AWL: ]ft -Ws LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Ilam Lay -In Lug(GBL4DBT) Rsco Flange Wg(SGB4) WReyWEEBWg(6.7) • 10-32 mounting hardware 1 1/4" mounting hardware 1/4"mounting hardware • Torque=5ft-L1b I Torque=75 in -lb Torque=30ft-Lb • AWG4-14-SoLidor Stranded I AWG4-14-SoUdor Stranded AWG6-14-SoLidorStranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACTTO PREVENT CORROSION System bonding is accomplished through modules. System grounding accomplished by attaching aground lug to any module at a location on the module specified by the module manufacturer. E -W BONDING PATH: E -W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicnoiaiLTM and splice. , - I I [Atwmawrn nod N-5 BONDING PATH: N -S module to module bonding is accomplished with bonding cla mp with 2 integral bonding pins. (refer also to alternate method ) in TRIMRAIL BONDING PATH: Trims iL to mod uLe bonding is accomplished with bonding clampwith integral bonding pin and bonding T -bolt. (refer also to alternate method i BLUE RAVEN 1403 N RESEARCH WAY BUILDING J 800 3774480 CONFIDENTIAL THE INFORMATION HE REIN CONTAINED SHALL NOT BE USED FOR THE RENE FIT OF ANYONE EXCEPT BLUE RAVEN SOLVE NOR SHALL IT BE DISCLOSED IN FSHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN CONNECTION FULL THE SALE AND USE OF THE RESPECTIVE EQUIPMENT PULLOUT THE PUTRITTEN PERMISSION OF BLUE RAVEN SOLVE NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL GAB Gur,Q CONTRACTOR aRS FIELD OPS 385 498 6799 SPEC SHEET SS U1tert@k AUTHORIZATION TO MARK To1NPuellg4fnlee. This withorizw Nv application of the CaNlirallon Marlys) &norm trebw ti the models assc De01n the Products) Corered eaNan wlwn male in amldenw AM Ne can®Wns set IBM In tic CwlNkelbn Agreement eM Usbang flpml. Thb wtlonu4m yw epplw b muligv pastae mWG(e) M Mlvd on Me w"whon pi m " Using Report. This document b Ne property of maMc Te&Yq SeMws and a not ha%hvMdv. The wMlwtbn mi may N] applied may at Illy local of the Poly Augcrhad To Apply WM1 AppFunU Uni2o.M Mmturor. Con EmMe Numinurn CAL id PllotovoM1aic MwmFm ing System, Sun Ma MeraMoslem slem Uarg Unirec lneallalan Guide, Rev PrMucl. No, 999ChBoSMrg Road Akira"' 14118eoadxay shot BE Addrpa: Cxl ate AbKmWe,NMUtO2 b elarg Prooncyl315311 Country: USA Country: China Kohm Nechells Jia Liu CO"bd' Tom Yourg CenMA: Room LUo ida-4822199 y8&1529>W09@ Plane: IRE 843-1418 Phone r8613621n5753 FAX: NA ISI NA kMuswin Email: twduninc.ca Emil; jMaAusecSrymecal coo Pally Authorized To Apply Mark: Samem ManulacWrer T Report awing Gsce: lake Forest, CA U.S.A./ Control Number: 5003705 Ausal3M by: r an Davidsnq Cedillcali anapor MN � Intertek This dwlmem wparsehe all prevtws Amoolzmons to Mi for the rom Report NumMr. wMift r y I My wm.er t f w.+ B n w W rr marts, Testing SeMws NA PSI ma INA East Algot In ROM, Mingo RIBI IL&I Tdgixsm wb395S3851 orBPJ9568) Pm 31221CU1872 ATM toy RayA t@393982Ll Page loll ATM Issued: 9'AW-2919 BLUE RAVEN 4A N RES REACH CHOY BUILD NO J FRESH UT84097 CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE LORAN SOLER NOR SHELF IT BE DISCLOSED IN WHOLE OR IN PACT TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN CONNECTION WITH THE SAFE AND USE OF THE RESPECTICA EQUIPMENT CATHOUTTHE WRITTEN PERMAISSION OF BLUE HAVEN SOLER TO PROFESSIONAL N rvol1�lcolbme CONTRACTOR ERS FIELD OPS 385.498 6700 ■ SHEET SS 1 0 Mmming Systems. Mounfirg Chances. CbmprgRetembnDerretand Ground Lugs brUse with Pal - Ssndrtllai: Plate PhobwM1ffic hbrLbs am Panels [UL 2]113: 2915 Ed. 11 PllotovoM1aic MwmFm ing System, Sun Ma MeraMoslem slem Uarg Unirec lneallalan Guide, Rev PrMucl. PUR2019MAR01 wish Anne, NOM Row Eaumicn Installation Gude Rev PUBM19PEB20 ran ed Name: LOR MON010: UnvdC SAM ATM toy RayA t@393982Ll Page loll ATM Issued: 9'AW-2919 BLUE RAVEN 4A N RES REACH CHOY BUILD NO J FRESH UT84097 CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE LORAN SOLER NOR SHELF IT BE DISCLOSED IN WHOLE OR IN PACT TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN CONNECTION WITH THE SAFE AND USE OF THE RESPECTICA EQUIPMENT CATHOUTTHE WRITTEN PERMAISSION OF BLUE HAVEN SOLER TO PROFESSIONAL N rvol1�lcolbme CONTRACTOR ERS FIELD OPS 385.498 6700 ■ SHEET SS 1 0 min;S-FM -- FRAME FLASHING & SLIDERS ■ ------ ■■ -- MICS -iIONGUIDE ------------------------------------------------------------------------------------------------------------------------#--PAGE------- PILOT HOLES: DriLL pi Lot ho Les for lag screws or structural screws (as necessary) at marked attachement points FLASHINGS: place flashings INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: • Insertflashings per manufacturer instructions NOTE: Use Lag screw or structural fastener with a maximum diameter of 5/16" • Attach sliders to rafters • Verifyproperrowto now spacing for mod uLe size (Mod NS+1') • Ensure that Trimrai LTM roof attachments in each now have sufficient engagement with slider dovetails for proper attachment. INSTALL SLIDERS AND ROOF ATTACHMENTS: Follow manufacturer instructions forflashing installation procedures NOTE If N-5 module edge is within 1-orthe shingle course above, you have the option to pivot / route slider et the attachment point to span the next course and cut shingles as required. Cut Shingtes asRequired 11 r ft-Ei I rrI�q Route slider .y1 �yy\ ---il--'----- - TLE IL __i_L�s Thann 1°___ s 0 rrI it � rl re BLUE RAVEN 1403 N RESEARCH WAY BUILDING J 800 3774480 CONFIDENTIAL THE INFORMATION HE REIN CONTAINED SHALL NOT BE USED FOR THE RENE FIT OF ANYONE EXCEPT BLUE RAVEN SOLVE NOR SHALL IT BE DISCLOSED IN FSHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN CONNECTION FULL THE SALE AND USE OF THE RESPECTIVE EQUIPMENT PULLOUT THE PUTRITTEN PERMISSION OF BLUE RAVEN SOLVE NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL GAB Gur,Q CONTRACTOR aRS FIELD OPS 385 498 6700 SPEC SHEET SS I 0 Cf - INSPECTION RECORD Occu: anc,/T e INSPECTION REQUEST LINE: (303) 234-59-1.'1 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m, to receive an inspection the following business day.** } Inspector Dust Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspedorl Comments Initials Pier Concrete Encased Ground (CEG) — Foundation / P.E. Letter i +zr� aaa n� r s �=.a ��. c ��or��.��::..�a r.a r �. �,. �a i . i r.x♦ s-_� � �i a.r�r.�t■ _�:�rr_� ,-Ta_�-rr r��� Underground/Slab Inspections Date .ovsev� s� Inspector Comments _ --- Initials Electrical .viewer Service Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contaci the Fire Protection District for your project. _ Plumbing P1_ am—. s►_ _■o__ _e_ __ v+r ®..ti armvc® .Jcibm1:1 J ®%JU11U WE K;;)V161W11gV-QJd[) VVOFR t-rjor 10 nova! COY I he AboVe Inspections Rough Inspections Date Inspector Comments _--I Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric" _ ^.�,�'�_Z7 De>s�S Rough Piumbing/Gas Line Rnugh klechanical Rough Framing Insulation --- Drywall Screw/ Mail Final Inspections Date inspector Comments _ Initials Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contaci the Fire Protection District for your project. _ ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical I Final Plumbing Final Mechanical Roof v_— Final Window/Doors Final Building I -- NOTE All items must be completed and approved by Planning, Public Forks, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. —�-� P—•....... .,...,.vv -- . c.. ate L %IBIlII.JICLt1U IfUlrl the r°Ire uistrict ana electrical low voltage by the Building Division. "For Inspection Time Window Requests — please email insptirnere9Liest ci.wheatridoe.co us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. *,ccupancy Is Not Permittedof Occupancy 1111 � � City of Wheat Ridge Residential Electric PERMIT - 201700068 ERMIT NO: 201700068 ISSUED: 01/18/2017 OB ADDRESS: 3690 Allison CT EXPIRES: 01/18/2018 OB DESCRIPTION: New electrical wiring; new lights and outlets for remodel of home - 200 amps ** CONTACTS *** WNER (303)912-6867 GRAY PROPERTIES ALLISON LLC UB (303)619-2702 Matthew Martinez 1 74 MEM Electr ;~-F�bC -� ** PARCEL INFO *** ONE CODE: UA / Unassigned USE: UA / Unassigned :UBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / ** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,000.00 FEES 'otal Valuation 0.00 Jse Tax 72.00 'ermit Fee 109.20 ,* TOTAL ** 181.20 ** COMMENTS *** k** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. [, by my signm ature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am le ally authorized to include all entities named within this document as parties to the work to be pertormed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit flee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The Jssuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable cmhr c of this jurisdiction. Approval of work is subject to field inspection. j Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the iwimetion. Please put the address of the inspection in the subject line. k. -'i C", 11 � Ft L 11%46 E(, i iJN REQI` ES7 ..INE. (30v - -, ►� � Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) A Foundation / .E, Letter I p C / eC Do Not pour Concrete Prinr Tn Anr°!rrw2l Of Tha Akr%,L,a 1.��......�:..... Underground/Slab Inspections Date�ICommentsMspeo'�ns Electrical Plumbing Do Not Coyar IIndarnrneone? r&r iRa6rnu/8n_ilaiq lAl....-!e ®..:.... Te A Rough Inspections Wall Sheathing ate I �� ---� _ Inspector Ipriti s _ _.... ..... ... �� Iv■ vru® ve ! ne R°11�VYC IQIti �Gil�(Tis'' Comments Mid -Roof Lath / Wall Tie A Rough Electric Rough Plumbing/Gas Line Rough mechanical it �.Bpugh Framing Insulation Drywall Screw/ Mail Final Inspections Date Inspector Initials Comments Landscaping & Parking ! Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2845. For ROW and drainage inspections call 303-235-2851. For fire inspections contact the Fire Protection District for your project. - ROW 8 Drainage /Public Works Dept. Fire In Final Ellectrical on /Fire Protection Dist. Electrical - �, Final Plumbing , Final Mechanical Roof Final Window/Doors ---�[ ,�e Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not cnnctitr,tP ar,thnr;�nr;^„¢ --"r........�. or lowvoltage permits —Please be sure that rough inspections B by the Building Division. are completed from the Fire District and electrical 16w voltage "For Inspection Time Winnow Requests — Please email iaaPLM.ereclues�cimheatridae.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Issued Protect _ Weather City of Wheat Ridge Residential Remodel PERMIT - 201601961 3RMIT NO: 201601961 ISSUED: 12/22/2016 )B ADDRESS: 3690 Allison CT EXPIRES: 12/22/2017 )B DESCRIPTION: Remove load bearing wall and creating vaulted ceiling area in the living room. Reroof 20 sqs. **Additional work to include interior remodel to existing 1st floor. ** CONTACTS *** RNER (303)912-6867 GRAY PROPERTIES ALLISON LLC (720)298-8446 Kryzsztof Nawalany 160269 Global EPC Services Inc. ** PARCEL INFO *** ONE CODE: UA / Unassigned USE: UA / Unassigned UBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / ** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 45,000.00 FEES otal Valuation 0.00 lan Review Fee 436.83 'se Tax 810.00 ermit Fee 672.05 nvestigative Fees 230.00 * TOTAL ** 2,148.88 ** COMMENTS *** ** CONDITIONS *** BT: Approved per plans and red -line notes on plans. Must comply with. 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. All roughs to be done at Framing Inspection. i CITY OF WHEAT RIDGE �(303) Building Inspection Division (303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: f -I Job Address: I (!� Permit Number: 0o) 000 6 F- ❑ No one available for inspection: Time /P:q5AV1_P:_ Re -Inspection required: CY ssNo When corrections have been made, call for r' -inspection at 303-2 4-5933 J Dater i i Inspector: (� �/ DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: A� f I Job Address: 36070 c 7 Permit Number: 20/7OOo6b, A 1oIolrL v vo-2 ❑ No one available for inspection: Time / 3 •'30 AM M Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: 61151/ Inspector: (inri 1" DO NOT REMOVE THIS NOTICE 3011ON SIH13AOW3H ION OO :ao}oadsuj Lf O£ BE65-tbEZ-EOE le uoijoadsui-aa ao; peo `apew uaaq aney suoi;oaaaoo uayM, spA :paainbaa uoi}oadsul-aa Wd� 55 r awil :uoi}oodsui aol apapna auo ON r 19 10 1 Q c)ICZ :aagwnN livaaad LLZ) (VCS 1-1 % V O 1b `) :ssaippd qof I -Y"41 1 4djjq :adA1 uoiloadsul 331ION N01133dSNI xe-J 6,769 -ZOO (000) • 0q1JJ0 5s8z-sOz (COO) aull uolloadsul ££69110 (£0£) uoisinia uoiloodsul 6uiplin8 !� 3Jala lV3HM =10 A113 3011ON SIH13AOW3t1 ION OO V :joloadsul � :ala(] ££65-b£Z-£o£ le uoiloadsui-aa joj Ileo `apew ueaq aney suoihaaaoo uggM.. (9 saA :paainbaa uoiloodsul-aa 0/9 S awil :uoiloodsui aol algaliena auo ON r oo 0 L l t2Z :aagwnN }iwaad 01,9E-:ssaippd gof J 7 :adA1 uoiloadsul 30110N N01103dSNI xe-4 6,768-2E0 (000) - agWO 558,7-90,7 (000) aull uolloodsul ££65-t£Z (£0£) uoisinia uoiloodsul Buiplin8 3Jala 1H3HM =10 A113 i CITY OF WHEAT RIDGE ' Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: f A..S Job Address: 3 t. f b iA i i i S v m Permit Number: � b j C o 19 ❑ No one available for inspection: Time `;� AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: `��� Inspector:2/✓ DO NOT REMOVE THIS NOTICE vi ®� s CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: b W .5 Job Address: (� 7�tJ �? 1 I i s n Ij GT Permit Number: f ❑ No one available for inspection: Time/ Q / AM/PM Re -Inspection required: Yes No * When corrections have been made, call for re -inspection at 303-234-5933 ,i C7 L z 1 T. Date:.4 7 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: '� / i f S p N CT 0 Permit Number: I I ❑ No one available for inspection: Time / PS -7 APM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 � L. _ Date: - .� Inspector: DO NOT REMOVE THIS NOTICE 3 1,,q 0 A l 11, S tM 'c Lx Y j From: Richard Mecabe <firemecabe@yahoo.com> Sent: Monday, April 3, 2017 10:22 AM To: Kimberly Cook Subject: Mecabe plumbing permit 201601961 Good afternoon mecabe plumbing LLC is no longer associated with gray properties for the address of 3690 N. Alyson Court wheat ridge I would like to at this time have my permit pulled from the job. Thank you Richard mecabe Owner of Mecabe plumbing LLC A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: + m Job Address: 3� �b %/`i S a rJ %t Permit Number: A 1, o fk S hrrr L AJ Y P 0 S -° o c CP 1`/ ��P L ri P c 'I ! i Tti C1 a P V C� f P) l/\) C S T VN ip ; l C (� _/ i r_� C ❑ No one available for inspection: Time3 `' AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE k � _ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: C q, n i. A)�- r. ! 9 C_enc G 6 G 4 -k cr C % > ❑ No one available for inspection: Time qj pM Re -Inspection required: " Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: F R', 1 'Iv5 M K 'r re, f Job Address: qt Permit Number: b / T 4 0 le I A) Pp If 0'J Pai PA17007 � KP - 13s Hat, PItA 4 i N kDol Asyra 49 An,CVAlVe �rcoS f� Cy�P�� i ti Sv A 4Jti� G� t! r nr r S N e o -7-A/I S �• L` �. t '7 JrU N C I, AS W J X5 4 o A / / v A moi= i f NS'l A/f eVX e M rV^1jIli elOff -,! Poles 'i u F/ a o YC.- ' 1, i ❑ No one available for inspection: Time I b : Y a AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: 'i Inspector: DO NOT REMOVE THIS NOTICE e i CITY OF WHEAT RIDGE �j�� Building Inspection Division / / (303) 234-5933 Inspection line __:�(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE C Inspection Type: kcG C <OA �6 Job Address: (90 n - -A-Permit Number: 1� C-:> A\krP f Ne'cU> <K \ - .�X ❑ No one available for inspection: Time.10-la--)A PM Re -Inspection required: Yes (:No) * When corrections have been made, call for re -inspection at 303-234-5933 Date: Inspector: �fi'ne- 'Qlae r_ DO NOT REMOVE THIS NOTICE I, by my signature, do he attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that i am to legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. 1 further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plan, an specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2.This permit shall expire 5 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date o36f expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official an may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Isuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Budding Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of Wheat Ridge Residential Electric PERMIT - 201700068 PERMIT NO: 201700068 ISSUED: 01/18/2017 JOB ADDRESS: 3690 Allison CT EXPIRES: 01/18/2018 JOB DESCRIPTION: New electrical wiring; new lights and outlets for remodel of home - 200 amps *** CONTACTS *** OWNER (303)912-6867 GRAY PROPERTIES ALLISON LLC SUB (303)286-9393 Kyler Carje 140106 Avalon Industries Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,000.00 FEES Total Valuation 0.00 Use Tax 72.00 Permit Fee 109.20 ** TOTAL ** 181.20 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. I, by my signature, do he attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that i am to legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. 1 further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plan, an specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2.This permit shall expire 5 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date o36f expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official an may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Isuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Budding Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. r Melissa Mackey From: Gabrielle Gray <gabrielle.gray63@yahoo.com> Sent: Tuesday, March 14, 2017 2:28 PM To: Melissa Mackey Subject: Re: City of Wheat Ridge Hello Melissa, Thank you for the email! I, Gabrielle Gray the Manager and Owner of Gray Properties Allison LLC, and 3690 Allison Court 80033 authorize Avalon Industries Inc to take over the electrical permit for MEM Electric. Thank you, Gabrielle Gray On Mar 14, 2017, at 11:43 AM, Melissa Mackey <mmackey@ci.wheatridge.co.us> wrote: Hi Gabrielle, Once I receive the notification from you for the contractor switch, I will include you on the email response I send to Kyler with Avalon with a copy of the permit showing Avalon as the electrician and the inspection notices he requested. Thanks! Melissa Mackey Senior Permit Technician 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2855 Fax: 303-237-8929 www.ci.wheatridge.co.us <image001. j pg> CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. Melissa Mackey Uto����. From: Av Kyler Carje <kyler@aiielectric.com> Sent: Tuesday, March 14, 2017 10:30 AM To: Melissa Mackey Subject: 3690 Allison,ct Request to take over electric, permit. GL insureance will be on it way here today, THX Kyler Carje Kyler@aiielectric.com Avalon Industries Inc. (o) 303-286-9393 (f) 303-286-1112 (c) 303-919-5019 CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 76 cl0 Permit Number: .2,o 14 0 G/ 1rjcg;4 1-ii__�nr•__% ❑ No one available for inspection: Time, AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 41 - Date: 3-, b -,i -7 Inspector: 6. DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L R / _ ,. a% f V_ e-4 Job Address: 6110 /-u-SSD V C 7` Permit Number: 2-,o /-7 00 13 hl"C011- "0/' wOyk�r5- ire ne��n{k^ ear; c d i (",rued e ec_k-1`< : 4 ,.1 & O P CA - i n S 8 to , /-, o k S. r ! /�—^ 2r4 T 11 G v- r n_, o S Gt Iij r a , Lot -s !'fir 5 0P z,,% , I- C r s lc J ►-�, (e,* S e (e " i -+q C i 2 ❑ No one available for inspection: Time �% AM/PM Re -Inspection required:Yes No *When corrections have be call for re -inspection at 303-234-5933 Date.? -6-'/1 Inspector: DO NOT REMOVE THIS NOTICE C+' KW Dyet � IN PE TION RECORD2XOccupancy/Type �� `' INE: 303 234-5933 1 INSPECTION REQUEST L ( ) Inspections will not be performed unless this card is posted on the project site. Call E the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector (Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground/Slab Inspections Date Inspector Initials Comments Electrical Wall Sheathing Sewer Service Mid -Roof Plumbing Do Not Cover Underaround or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough f=raming Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials � Comments Landscaping & Parking / Planning Dept. inspections from these entities shoul4 be requested one week in advance. Fc!- landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE. All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. *For low voltage permits - Please be sure that rough inspections are completed from the Fire District and eiectricai iow voltage by the Building Division. **For Inspection Time Window Requests - Please email insgtimereciuestCa-Dci.wheatridge.co.us by 8:00 A.M. the day of the inspection with the property address in the subject line of the email. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE ?411 U116 Inspection Type: L--'~ Job Address: % jam LfSvrd az Permit Number: ❑ No one available for inspection: Timet-' AM& Re -Inspection required :es No *When corrections have bean made, call for re -inspection at 303-234-5933 Date: '3-3-17—inspector: DO NOT REMOVE THIS NOTICE e i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Pe -f5 R- Inspection Type: Z rte - Job Address: 3610 c Permit Number: 2a/ 7D0®G g fa!'� l , f;� �� -;,' ) ?, 1 roti ,. ,1, l 6 ,. 4- -x11 1, ' 1"k 40 .)1 j /-z ❑ No one available for inspection: Time :0 Aw Re -Inspection required:,Yes No * When corrections have been made, call for re -inspection at 303-234-5933 Date Inspector: P r°f' (.- �_ DO NOT REMOVE THIS NOTICE " + i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 36 90 A'L[-/ S-aN C 7 - Permit Number: 2ol A o 147 7 / ✓: CF e,, q I ❑ No one available for inspection: Time AMIPM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: y` � Inspector: DO NOT REMOVE THIS NOTICE G9y � i fJ� CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: P Job Address: 3 &, k7 c P-,. Permit Number: ❑ No one available for inspection: Time i 2 ` ¢ AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 r= n Date: r Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division / (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M 1 l) 1 l►1 / S Job Address: (c �? t� A 1) i S 0 w Permit Number:y 1 L ®� 9 L/ S 1-1; 1 () 0V M PIC ❑ No one available for inspection: Time J <l U AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 * y? Date: j Inspector: DO NOT REMOVE l HIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: S /? C Job Address: 3L9'0 4 11 i S 6 ij U Permit Number: -)Lo / C U / f 6/ ❑ No one available for inspection: Time P ' C/()AM/PM Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 303-234-5933 Date: >- Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: I/ 1-C C J 111 / D Job Address: 3 C a Ili d CT Permit Number: / h) q CnxrJ a l - u R,Nf AQn)PN-/ -rD�1 T P r 0 1i t) ❑ No one available for inspection: Time / Z Re -Inspection required: Yes No ' * When corrections have been made, call for re -inspection at 303-234-5933 Date: I - S - Inspector: � DO NOT REMOVE THIS NOTICE �J7 '� �' � 6 / 4)6 / January 24, 2017 Gray Properties 2602 W 20 Ave Unit 10 Denver, CO 80211 Subject: Concrete Foundation Observation 3690 Alison Ct. Wheat Ridge, Colorado 80033 Gabrielle 23651 E Easter Dr. Unit 208 Aurora, CO 80016 Tet 1-(720)-298-8446 kris ;kpneng.com At your request, we visited the above -referenced site on January 6, 2017. The purpose of our visit was to observe the placement of footing and reinforcing. Based on our visual observation, we concluded that the lootings were placed in general conformance with the design drawings. Regarding any additional information or questions, we can be contacted at the address above. Cordially, '1 r; :� 30878: 7 �. ©�Fs�'�ONAI E�a4 Krzysztof P. Nawalany, P.E Managing Member Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: (A i E C Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please print): Q ('c_ Phone: `Sy -' ] Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: s Contractors City license #; ` Phone: 9 `-E Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: M cc'- �O' W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description'of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING COMMERCIAL ADDITIONH RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Sq. FtJLF Btu's ` l�) .0 0 Gallons I� Amps Squares Other City of Wheat Ridge Residential Electric PERMIT - 201700068 PERMIT NO: 201700068 ISSUED: 01/18/2017 JOB ADDRESS: 3690 Allison CT EXPIRES: 01/18/2018 JOB DESCRIPTION: New electrical wiring; new lights and outlets for remodel of home - 200 amps *** CONTACTS *** OWNER (303)912-6867 GRAY PROPERTIES ALLISON LLC SUB (303)619-2702 Matthew Martinez 140074 MEM Electric Systems, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,000.00 FEES Total Valuation 0.00 Use Tax 72.00 Permit Fee 109.20 G��►`' ** TOTAL ** 181.20 *** COMMENTS *** *** CONDITIONS *** Must comply w/ 2012 IRC & 2014 NEC. Subject to field inspection. I by my signature do hereby attest that the work to be performed shall comply with all accompanyingg approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permtt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and fiat all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. I - /F — / Signature of OWNER 6r COIYRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Auilding Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of Wheat�idge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 I FOR OFFICE USE ONLY I Date: Plan/Pennit # ow Plan Review Fee: Building Permit Application ' Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: -3(ojQ k;5,,/u CGL r' Property Owner (please print): G,-_ , Er-' rt ,-z A (; s� -LLC Phone: _3o3 -i I Property Owner Email: Mailing Address: (if different than property address) Address City, State, Zip: Arch itect/Enaineer: � Architect/Engineer E-mail: �� Phone: Contractor: M& K ee.c�f_"e_ Contractors City License #: Phone: ? o Contractor E-mail Address: :Me 41c /e c Ori"C sig she+ 5' 11 C /v 4,'l 6 o 4501 Sub Contractors: Electn' a � i y License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) ii Io✓5(✓, -3 bV1111r'0v_5" /XC .I., tc. 1{C4elz — t,, // e1,v b/%anC'GL C ,'rc i, , .1 S a ,N0,,,,. /") 1,- S -- /" C , o , f A- / 5 Sq. FULF Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRAC R ,or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: � n 7TltCr,_-- Ella { ,'ne Z SIGNATURE: i%~�/''— DATE: ZONING COMMMENTS Reviewer: BUILDING DEPARTMENT COMMENTS Reviewer. PUBLIC WORKS COMMENTS Reviewer PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ City of Wheat Ridge Residential Remodel PERMIT - 201601961 PERMIT NO: 201601961 ISSUED: 12/22/2016 JOB ADDRESS: 3690 Allison CT EXPIRES: 12/22/2017 JOB DESCRIPTION: Remove load bearing wall and creating vaulted ceiling area in the living room. Reroof 20 sqs. **Additional work to include interior remodel to existing 1st floor. *** CONTACTS *** OWNER (303)912-6867 GRAY PROPERTIES ALLISON LLC GC (720)298-8446 Kryzsztof Nawalany 160269 Global EPC Services Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIR.E,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 45,000.00 FEES Total Valuation 0.00 Plan Review Fee 436.83 Use Tax 810.00 Permit Fee 672.05 Investigative Fees 230.00 1q J ** TOTAL ** 2,148.88 *** COMMENTS *** *** CONDITIONS *** BT: Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. All roughs to be done at Framing Inspection. City of Wheat Ridge Residential Remodel PERMIT - 201601961 JN° PERMIT NO: 201601961 ISSUED: 12/22/2016 JOB ADDRESS: 3690 Allison CT EXPIRES: 12/22/2017 JOB DESCRIPTION: Remove load bearing wall and creating vaulted ceiling area in the living room. Reroof 20 sqs. **Additional work to include interior remodel to existing 1st floor. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. SignatrWe of OWNER or KONTRACTOIV(Circle one) Date I, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official an may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The is uaf e or granting o p t construed to be a permit for, or an approval of, any violation of any provision of any ap lic bl ode.or ordi n of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of Wheat id COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29t' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Add to Permit # r Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Owner (please print): �j '� , �, t l-3 el Y Phone: Property Owner Email: �� �� - 9V- 1 0�' Y A s�3 - �%� 2 - �� b7 . CSM Mailing Address: (if different than property address) Address: 2 L� 62 �SUA �\ �0 City, State, Zip: 0 rM \j (-- CO, Submitting Company: Contact Person: Phone: Contractor: �� �� L 'C SSR U� -f-E S /Aj (!�7, Contractors City License #: %b"O Z 6 9 Phone: 7Z -O Contractor E-mail Address: Xf/ 5 P/U F- /t��T-. Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour - 2 hour minimum). Description of revised/amended work: S E I \ODEL To I N C L UnC L C,6T M00 S-TQOcTDO Sq. Ft./LF Amps Btu's Squares Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) q00 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list ntity on this application. CIRCLE ONE: (OWNER) (C NTRACTOR) r (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: Kh—`?`;0% Ott AlAuALAk/SIGNATURE: fes' tejce DATE: ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ December 15, 2016 Ms. Gabrielle Gray 3690 N Allison Ct Wheat Ridge, CO RE: Limited Asbestos -Containing Building Materials Inspection Residential Structure - Renovation 3690 N Allison Ct - Wheat Ridge, Colorado Dear Ms. Gray: Atlas Environmental inspected the residential structure, located at 3690 N Allison Ct in Wheat Ridge, Colorado for asbestos containing building materials (ACBM) on December 8, 2015. Colorado Department of Public Health and Environment (CDPHE)-licensed Asbestos Inspector Andrew Nelson, (license #15428) conducted this limited inspection under an agreement between Atlas Environmental and Gabrielle Gray. The purpose of the inspection was twofold: 1) determine locations and conditions of asbestos containing products in the scheduled renovation/ demolition areas at the Site; 2) determine the impact these materials will have on scheduled renovation/demolition. Asbestos products found at the Site were limited to: No areas sampled contained asbestos All accessible areas within the Site were viewed and suspect materials touched by the inspector to determine the location, condition, and friability of observed asbestos material. All bulk samples were submitted for PLM analysis. When suspect material was initially sighted, bulk samples were usually collected. By definition, a homogeneous area means an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture, and is installed within the same period. Atlas has had extensive experience with older buildings that have been abated during demolition or renovation projects. Occasionally, additional asbestos was discovered during demolition of concealing ceiling, wall, or flooring materials. Sample analysis reported as "None Detected" should be interpreted as meaning no asbestos was observed in the suspect material above the reliable limit of detection, (1% by visual estimation) for the PLM method. The following materials did not contain asbestos: • White foamy texture w/ white paint • White/Tan Drywall 13386 Mariposa Ct, Westminster, CO atlasenvironmentaI@icloud.com 720-985-8805 Appendix I indicates the sample locations. The PLM Report in Appendix II indicates the results of PLM analysis for bulk samples collected in the scheduled demolition areas. The PLM Report shows the room or area in which the sample was collected and provides a description of the sampled material. Any product containing more than 1% fibrous asbestos, when analyzed by PLM, is considered a potential hazard by the Environmental Protection Agency (EPA). PLM is the EPA -recognized method for determining fibrous bulk asbestos content. Additionally, the EPA indicates that further analysis by point counting be performed to confirm asbestos content for friable materials found to contain less than ten percent asbestos by visual area estimation. Point counting analysis may be omitted if the material is assumed to contain more than one percent asbestos and is then handled accordingly. All samples collected by Atlas were analyzed by Reservoirs Environmental, Inc.'s NVLAP-accredited laboratory in Denver, Colorado. Based on observations made at the Site, and results of the analysis of bulk samples collected during the survey, Atlas recommends the following: 1. Friable ACBM that is in good condition and is not disturbed does not require additional action. However, if the friable material becomes disturbed, or is in poor condition, then stabilization measures need to be taken. No friable materials observed during this investigation require stabilization at this time. 2. If ACBM are to be removed or disturbed as part of renovation/ demolition activities the ACBM should be removed under abatement conditions before renovation begins. 3. According to Colorado Regulation #8, CDPHE must be notified for all demolitions of all facilities and all asbestos abatement projects that exceed the trigger levels, whatever is the lesser quantity. The notification requirements apply to both friable and non -friable asbestos materials. Notifications must be postmarked or delivered at least 10 working days before initiating abatement activities, and must be made using CDPHE forms. Forms can be obtained by contacting the CDPHE Asbestos Notification and Information Section at 303-692-3100 or online through the CDPHE website at www. cdphe.state.co.us. 4. Collect additional bulk samples from previously concealed materials that may be revealed during demolition activity, or from materials outside the original inspection scope of work. "Suspect" material includes any material serving as a sprayed on or troweled on acoustic or fireproofing surface; floor and ceiling tiles; transite panels, siding or shingles; thermal insulation or any material associated with mechanical systems; or any binding agent such as tar sealant, mastic adhesive, roofing tar, caulking, et cetera. Colorado Regulation #8 requires bulk samples in public buildings be collected by a licensed Asbestos Inspector. If any material cannot be positively identified as non asbestos containing by the analytical results of samples collected during this inspection, it should be treated as 13386 Mariposa Ct, Westminster, CO 80234 atlasenvironmental@icloud. corn 720-985-8805 ENVIR sENTAL asbestos until a sample of the newly identified suspect material can be collected and analyzed by PLM. The building owner should be aware that removing ACBM does not discharge ownership. During transport or after burial in an EPA -approved landfill, any contamination throughout the lifetime of the material remains the responsibility of the building owner. Atlas has endeavored to inspect the existing conditions within the affected areas using CDPHE inspection protocols. Regardless of the thoroughness of a survey, it is possible that some areas containing asbestos were overlooked or inaccessible. This report presents general descriptions of various construction materials and the general locations where these materials were encountered. If questions arise during the planning for renovation, demolition or other construction, Atlas should be notified to permit us to review the situation and present recommendations. This report has been prepared on behalf of and exclusively for the use of the Gabrielle Gray. The conclusions expressed by Atlas regarding the conditions of the site are based solely on the observations made on December 8, 2015, the data collected during this survey, and the laboratory results of the samples collected and analyzed. The beneficiaries are hereby advised that conditions observed are subject to change. This report and the findings contained herein shall not, in whole or in part, be disseminated or conveyed to any other party or be used or relied upon by any other party, in whole or in part, without Gabrielle Gray or Atlas's prior written consent. Atlas appreciates this opportunity to provide asbestos consulting services to Gabrielle Gray. We have enjoyed working with you on this project and took forward to meeting your needs in the future. Should any questions arise concerning this report, please contact us at (720) 985-8805 Sincerely, Andrew Nelson CDPHE #15428 13386 Mariposa Ct, Westminster, CO 80234 atlasenvironmentaI@icloud.com 720-985-8805 3690 Allison Court Mechanical - Service and certify existing furnace, AC unit and fireplace. Electrical - Update Electrical Panel Update cloth wrapped wires to Romex through out home Replace and update all fixtures and GEIs Add 2 Low Voltage exterior landscape lights at the front entry of the home Update W/D Hook ups Plumbing - Update and reconfigure master bath and guest bath in existing locations Update kitchen cabinets and appliances in pre-existing locations Add gas line to pre-existing cooktop location in island Updated water heater relocated to garage P le ASE kleA6 City of Wheatp,�dge 300 A t / %sap - COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 All work is subject to Field Inspection and must comply with the 2012 IRC,2012 IPC, 2012 IMC and the 2014 NEC Rough Framing and Wood Requirements 1 1 The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough heat and ventilation are complete. The building should be fully enclosed with the roof covering and siding in place. 12 Protection from decay shall be provided in the following locations by the use of naturally durable wood or wood that is preservative treated in accordance with AWPA U1: (IRC R317) A. Wood joists closer than 18 -inches and wood girders closer than 12 -inches to grade located within foundation periphery. B. Wood framing members that rest on concrete or masonry foundation walls and are less than 8 -inches from the exposed ground. C. Sills and sleepers on a concrete or masonry slab that is in direct contact with the ground. D. Wood girders entering concrete or masonry walls with a clearance less than 'h -inch. E. Wood siding, sheathing, and wall framing less than 6 -inches above the ground. F. Wood members supporting moisture -permeable floors or roofs that are exposed to the weather. G. Wood furring strips or wood members attached directly to the interior of below grade exterior masonry or concrete walls. H. Wood in contact with the ground, embedded in concrete in direct contact with the ground or embedded in concrete exposed to the weather that supports permanent structures intended for human occupancy shall be approved pressure -preservative -treated wood. 13Accessible under -floor areas shall be provided with a minimum 18 -inches x 24 -inches opening through the floor or 16 -inches x 24 -inches opening through the perimeter wall. When the access is through a below -grade wall an areaway of not less than 16 -inches x 24 -inches must be provided. Where equipment is located beneath the floor, the access opening must be within 20 -feet of the equipment and allow the removal of the largest piece of equipment. (IRC R408.4 and M1305.1.4) 14 Basements greater than 200 square feet and every sleeping room shall have at least one operable emergency and rescue opening or a door to the exterior. 115 mergency escape and rescue openings shall meet the following requirements: A minimum clear width of inches, a minimum clear height of 24 -inches, with a total net clear opening of 5 square feet for grade level windows and 5.7 square feet for all others. A sill height of not more than 44 inches measured from the finished floor to the bottom of the clear opening. Window wells for emergency escape and rescue shall provide a minimum net area of 9 square feet with minimum horizontal projection and width of 36 -inches. The area of the widow well shall allow the emergency escape and rescue opening to fully open. (IRC R310) 16 Columns must be restrained to prevent lateral displacement at the bottom end to insure against uplift. (IRC R301.2.1, R407.3) al ire blocking shall be installed to cut off all concealed draft openings in the following locations: (IRC1) a. In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor levels, and at 10 -feet horizontal intervals. B. At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, and cove ceilings. C. In openings around vents, pipes, ducts, cable, wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. Il. In www.ci.wheatridge.co.us concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the run of the stairs at unfinished walls. 18 At least one egress door shall be provided for each dwelling unit. The egress door shall be side -hinged, and shall provide a minimum clear width of 32 -inches. Egress doors shall be readily openable from inside the dwelling without the use of a key or special knowledge or effort. (IRC R311, R311.2) 019 here shall be a floor or landing on each side of each exterior door, The landing must be no lower than 73/- es below the top of the threshold of the door provided the door does not swing over the landing. (IRC R311.3) 20 Handrails shall be provided on at least one side of stairways with 4 or more risers and ramps with a slope exceeding 1:12. Handrails shall be mounted 34 -inches to 38 -inches above the nosing of the treads. Handrails must be continuous for the entire length of the stairs and provided with a minimum space of 1 %2 -inch between the wall and the handrail. Ends shall be returned or terminate in newel posts or safety terminals. See the requirements and more information. (IRC R311.7.8) 21 Handrail Grip Size Shall Be: A. Circular Handrails: 1'/ -inch to 2 -inches perimeter. B. Non -Circular: 4 -inches to 6'/ -inches perimeter with a maximum cross section of 2'/ -inches. C. Perimeter Dimension Greater than 6'/ -inches: shall have a finger recess on both sides. 22 Guards must be provided for porches, screened porches, balconies, fixed seating and raised floor surfaces more than 30 -inches above the floor or grade below. Guards must have a minimum height of 36 -inches. Open sides of stairs with a total rise of more than 30 -inches above the floor or grade below shall have guards not less than 34 -inches high. Intermediate rails shall not allow the passage of a 4 -inch sphere. (R312)Window fall protection must be provided for window openings less than 24 inches above the finished floor and more than 72 inches above grade or surface below. (R312.2) 23 Ceiling heights for habitable rooms, hallways, bathrooms, toilet rooms, laundry rooms, and basements shall be a minimum of 7 -feet measured from the finished floor to the lowest ojection of the ceiling. Non -habitable basements may have a ceiling height of 6 -feet, 8 -inches with clearance below beams and ducts of 6 -feet, 4 - inches. Bathroom may have a ceiling height of 6 -feet, 8 -inches at the fixture front clearance area and over the fixture. (IRC R305.1) 524 ttic access must be provided for attics that exceed 30 square feet and that have a vertical height of 30 -inches o greater. The access must be located in a hall or readily accessible location with a minimum 22 -inches x 30 - inches access opening. The access must provide a minimum of 30 -inches headroom. (IRC R807) 25 Enclosed attic and rafter spaces must have cross ventilation for each space through screened openings. The total net free ventilating area shall not be less than 1 to 150 of the area of the space ventilated. The area may be reduced to 1 to 300 if 50-80% is provided by ventilators located in the upper portion of the space or if a vapor barrier not exceeding 1 perm is installed on the warm side of the ceiling. At least a 1 -inch space is required between the roof sheathing and the insulation at the location of the vent. (IRC R806) 26 Rafters must be framed to a minimum 1 -inch nominal ridge board that is not less than the depth of the cut end of the rafter or to each other using a gusset plate. Hip, and valley rafters shall be a minimum of 2 -inches and not less in depth than the cut end of the rafter. Hip and valley rafter shall be supported at the ridge by a brace to a bearing partition or be designed. (IRC R802.3) 27 Rafters and ceiling joists having a depth -to -thickness ratio exceeding 5:1 shall be provided with lateral support at points of bearing to prevent rotation. Rafters and ceiling joists having a depth -to -thickness ration exceeding 6:1 shall be supported laterally by solid blocking, diagonal bridging or a continuous 1 -inch by 3 -inch ' wood strip nailed across the rafters. (IRC R802.8) Roof trusses or rafters must be attached to supporting walls with approved hurricane clips. Trusses must be braced to prevent rotation and to provide lateral stability in accordance with the construction documents and the individual truss design drawings. (IRC R502.11.2, R802.11) 28 Trusses must be designed and fabricated in accordance with ANSI/TPI 1. A licensed professional shall prepare the truss design. Trusses must be legibly marked within 2 -feet of the center to identify the manufacturer, the design load, and the spacing. Truss engineering and layout must be provided at the site at the rough framing inspection. (IRC R502.11 and R802.10) 29 Roofing material Wood roofs in the plain areas are limited to minimum Class "B" roof coverings. Shingle installation shall meet the manufacturer's high -wind installation procedures in areas where wind load is greater than 105 mph (V3 S). Chapter 9, R301.2.1, R325, and manufacturer's listing 30 All habitable rooms shall be provided with aggregate glazing area for natural light of not less than 8% of the floor area of such rooms. The glazed areas need not be installed in rooms where section M1507 is satisfied and artificial light is provided at an average of 6 foot candles at a height of 30 inches. Ve fety glazing shall be installed in the following hazardous locations and be permanently labeled as safety or red glazing: glazing panels in doors; glazing enclosing spas, bathtubs or showers; glazing panels adjacent and within 24 -inches of the edge of a door; glazing panels greater than 9 square feet within 18 -inches of the floor; glazing used for railings; glazing used for barriers for swimming pools and spas; and glazing enclosing stairways, landings, and ramps within 36 -inches horizontally of a walking surface. (R308.4 through 308.4.7). 32 Skylights must be: (IRC R308.6 ) A. laminated glass (with restrictions). B. fully tempered glass (with retaining screen). C. heat -strengthened glass (with retaining screen). D. wired glass (with retaining screen in multiple glazing condition only). E. approved rigid plastic. F. Skylight U -factor required U-0.45. Skylights installed on roofs flatter than 3 units vertical to 12 units horizontal must be mounted on a curb4-inches above the roof. Heating and Ventilation Requirements 33 Crawl spaces shall be provided with conditioned air in compliance with Section N1102.2.10. Crawl space walls shall be insulated. Crawl space wall insulation shall be permanently fastened to the wall and extend downward from the floor to the finish grade level and then vertically and/or horizontally for a least an additional 24 -inches. Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder with a minimum thickness of 10 -mil. All joints of the vapor retarder shall overlap by 6 -inches and be sealed and taped. The edges of the vapor retarder shall extend at least 6 -inches up the stem wall and shall be attached to the stem wall. N1102.2.9.2.2 Ventilated crawlspaces. Ventilated crawlspaces shall be provided with insulation. (IRC R303.1,) 34 Habitable rooms must be provided with outdoor openings for ventilation equal to at least 4% of the floor area and shall have heating facilities capable of maintaining 68° at 3 -feet above the floor and 2 -feet from exterior walls. B. The windows need not be openable in a room where an opening is not required to be an egress window and a mechanical ventilation system is capable of producing 0.35 air change per hour in that room, or a whole house mechanical ventilation system provides 15 cubic feet of outdoor air per minute. 35�athroom exhaust fans shall exhaust directly to the exterior and must be provided in bathrooms where indows of at least 3 square feet are not provided. The mechanical ventilation must be capable of providing an exhaust capacity of 50 cfin intermittent or 20 cfin continuous exhaust. (IRC R303.3, M1507.4) 36 ryer vents must be rigid metallic, independent of all other systems, shall terminate outside the building, be equipped with a back draft damper, and sized and terminated per the manufacturer. The maximum length of the exhaust duct shall be 25 -feet (Unless approved under the manufacturer's listing) from the connection to the transition duct from the dryer to the outlet terminal. Where fittings are used, the maximum length of the exhaust duct shall be reduced in accordance with (IRC Table M1502.4.4.1) Flexible transition ducts are limited to 8 -feet, shall not be concealed within construction, and shall be listed and listed per UL 2158A. (IRC M1502) 37 ppliances and equipment shall be installed in accordance with the conditions of their listing. anufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1, M1401.1,M1902.2) 3 ppliances shall be accessible for inspection, service, repair and replacement without removing permanent construction. 30 -inches of working depth and width shall be provided in front of the control side of an appliance. (IRC M1305.1) 39 as and solid fuel appliances located in a garage and hazardous locations shall be elevated so the source of ition is at least 18 -inches above the floor. Rooms and spaces that are communicate directly with the garage and are not part of the living space shall be considered as part of the garage. Appliances located in garages must be installed at least 6 -feet above the floor or protected from motor vehicle impact. (IRC G2408.2, G2408.3) 40 Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407.1) Air for combustion, ventilation and dilution of flue gases for appliances installed in buildings shall be provided with the requirement of (G2407.6 through G2407 .9).One opening shall be 12" below the ceiling and one opening shall be 12 " above the floor. 41 Gas burning appliances may not be located in or obtain combustion air from: a sleeping room, bathroom, toilet room, or storage closet unless it is a direct vent appliance or installed in an enclosure that opens only into a bedroom or bathroom in and such enclosure is provided with a solid weather-stripped door, a self-closing device and all combustion air is taken from the outdoors. (IRC G2406.2) 42 Gas logs installed in solid fuel burning fireplaces shall be tested in accordance with ANSI Z21.60 and installed per the manufacturers installation instructions. Gas logs installed in bedrooms must be direct vent or provided with an approved source of outside combustion air. The approved gas log set must be installed in the Solid -fuel burning appliances at the final inspection. (IRC G2406, G2432, and G243 1.,43 $, BW, and L vents and factory -built chimneys must be provided with a clearance to combustibles per them anufacturer's listing. Where vents pass through insulated assemblies, they must be provided with an insulation shield. A clearance of 9 -inches is required between single wall vent connectors and combustibles. Gas vents must penetrate through the roof flashing, jack or thimble and terminate in a Chimneys listed cap or per the manufacturers listing. Decorative shrouds installed at terminations shall be listed and installed per the manufacturer. (IRC G2425, G2426, G2427) Electrical Requirements 44 All electrodes present at each structure shall be bonded together to form one grounding electrode system to include: Concrete Encased Electrodes (UFER), water piping, ground rings, grounding rods, and plate electrodes. Bonding shall ensure electrical continuity. The electrode conductor must be connected in an approved manner and inspected prior to concealing. (IRC E3607, E3608, E3609, E3610, E3611) (42511 hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical ection at the time of rough inspection. Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at east 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevent air leakage through the fixture into the ceiling cavity. (IRC N1102.4.5) 47 amper -Resistant receptacle outlets are required in every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14) A. Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the counter top and spaced so no point exceeds 24 -inches from an outlet. B. Island and peninsula counters with a length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet. C. At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. A least one receptacle outlet must be installed in each laundry, basement, attached garage and detached garage with power. C. Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet within 25 -feet of the equipment. D. Hallways 10 -feet or more in length. (E3901.1) 48 wo 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining area. 49At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch circuit s 11 supply laundry. (IRC E3703.2, E3703.3, E3901) c50 round fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the lowing locations: bathrooms, garages, unfinished grade level accessory buildings, at exterior locations, crawlspaces, unfinished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks, boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location. (IRCE3902, E3902.11) 5&ombination type arc -fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch c'rcuit outlets in receptacle outlets are required in every family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, hallway, closets, and similar dwelling areas. (IRC 3902.12) &2t let one wallswitch-controlled lighting outlet shall be installed in every habitable room, bathroom, ay, (1 Oft) stairway, attached garage, detached garage with electric power, and at the exterior side of each outdoor egress door having grade level access. Attics, under floor spaces, utility rooms and basements containing equipment or used for storage must be provided with a switch operated light. (IRC E3903) ;XY 53 )Smoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring with 'baftery backup and shall be interconnected so the actuation of one alarm will activate all alarms in the dwelling unit.(R314.5) Smoke alarms shall be installed in the following locations: (IRC R314) A. In each sleeping room; B. Outside each sleeping area in the immediate vicinity of the bedrooms; and C. One on each additional story including basements. 5 arbon Monoxide alarms are required in a single-family dwelling that has fuel -fired appliance(s), or a � jifkplace, or an attached garage. The alarm must be installed within 15 -feet of the entrance to each sleeping room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and has a battery backup. They may be combined with a smoke -detecting device if the combined device complies with applicable law. (IRC R315) 55 lothes closet lighting shall be limited to surface -mounted or recessed incandescent fixtures with completely closed lamps, and surface mounted or recessed fluorescent fixtures. Recessed fluorescent fixtures shall have a minimum 6 -inch clearance to the nearest point of storage. 56 corking space must be provided around energized equipment for servicing and maintenance. The minimum dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the equipment. Working space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2) 57rectrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or cculate n wiring compartments or other electrical parts. Fixtures installed in wet locations must be labeled "suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations" or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8, E4002.9,E4002.10, E4003.9, E4003. l 0,E4003.11) Plumbing (, WV systems shall be tested on compellation of the rough piping installation by water or for piping system btlier than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed .1) Water test 10 feet above the highest fitting connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes. 2) Air test shall maintain 51bs of pressure for 15 minutes. (5:9 iping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1) 60athtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. Shower valves must be�pressureaTancelthermostatic mixing valves;, Shower receptors shall have a curb threshold not less than 1- nch e ow t e si es and bac o t e recep or. The curb shall measure a minimum of 2 - inches to a maximum of 9 -inches above the top of the drain. (IRC R307, P2708, P2709) Jd The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 62 Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic axing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or CSAB 125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 1201. (IRC P2708.3,P2713.3) 9hower doors shall have safety glazing, hinged shower door shall open outward (R308.4.5, P2708.1) 64 Backflow prevention must be provided to prevent contamination of potable water. This includes but is not limited to: hose connections, irrigation systems, boilers, solar systems, fire sprinklers, and dishwashers. (IRCP2902.2, Table P2902.3, P2717) Insulation a_520 Walls (new construction) 49 Ceiling R-19 Crawlspace Windows .32 Floor R-30 60 Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum R-6. ( N 1103.2. 1) 07 Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. Wallboard Requirements Wallboard Requirements 68 The garage shall be separated from the residence and its attic by materials of not less than 'h -inch gypsum ,board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8 -inch Type X gypsum board. Openings between the garage and residence shall be equipped with solid wood doors not less than 1 -inch in thickness, solid or honeycomb core steel doors not less than 1 -inch thick, or 20 -minute fire -rated doors. Openings are prohibited between garages and rooms used for sleeping. Doors between attached garages and living space shall be weather stripped to the degree necessary to make them airtight and shall be self-closing and self -latching. (R302.5.1) 61t Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with '/2 -inch gypsum board (IRC R302.7). 70', Cement, fiber -cement, glass mat gypsum backer and fiber reinforced gypsum in compliance with ASTM C 1.88, C 1325, C 1178, or C 1178 and installed in accordance with manufacturer recommendations shall be used as backers for wall tile in tub and shower areas and wall panels in shower areas. (IRC R702.4.2) . 71 Nail spacing for gypsum board 1/2 Ceiling 16oc 7" nails 12" Type S screws, 1/2wall spacing 24"oc 8"nails, 12 "screws. 5/8 ceiling 16oc 7" nails 12"type S screws 5/8 wall 24oc 8"nails 12" type S screws. 72 Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic tile or other required nonabsorbent finish material shall conforin to ASTM C1396 , C1178 or C1278. All cuts and exposed edges shall be sealed. (IRC R702.3.8) Final Inspection Requirements 73 Buildings shall have approved address numbers, building numbers or approved building identification i jplaced in a position that is plainly legible and visible from the street or road fronting the property. 4" high, with a minimum stroke of 1/2" (IRC 319) 74 All dwellings shall have a controlled method of water dispersal from roofs that will collect and discharge all roof drainage at least 5 -feet from the foundation. Gutters, downspouts, downspout extensions shall be deemed adequate to meet these requirements. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6 -inches within the first 10 -feet. (IRC R401.3 and R801.3) Bill Myers Plans examiner/ Combination Inspector 7500 W. 29Th Ave Wheat Ridge, Co 80033-8001 303-235-2878 f3 LA 4' x 8' PLYWOOD PANEL fl" FOR ROI AND J" FOR FLOOrAl low,: 3�1 OPARTIAL FOUNDTION PLAN SCALE 1/4 2-2X8 02 a W/R42 IN _.ULATION 2-2X6 POST - 2 -2X8 OR 2-2X10 m cm W/R21 INSULATION' cn LU t to U_ Lu qyq 2-2X8 0 2 0 OC eui AT SLOPE cr) z W R42 INSULATI N 0 cm _j Z OR 2X1 0 @ 16 OC AT SLOPE ftl 00 0 < V) cc < cm 1 U_ to x U- 2-2X6 POST- 0 cm 2X4 WALL ON TOP OF DOUBLE JOISTS W/R21 INSULATION* U) x ft 2-2X8 0 2 07 Oc W/R42 INS-OULA-hON OR 2X1 0 0 16" OC wilff"ON W/R42 INSULATION 2 0 GENERAL NOTES/SPECIFICATIONS GENERAL "ENERAL NOTES FOR LAMINATED AND STRUCTURAL TIMBER MEMBERS -7 I PARTlAL ROOF OR FLOOR PLAN 3 (UBLOCKED DIAPHRAGM) LEGEND STEEL BEAM LVL BEAM WOOD BEAM JOIST/TRUSS SPAN (BEARING CONDITION) JOIST/TRUSS EXTENTS JOIST/TRUSS ( 'FLUSH CONDITION) CROSSHATCHING INDICATES OVERFRAMING (RE: NOTE #7) CROSSHATCHING INDICATES BEARING WALL (TYP. U.N.O.) INDICATES FRAMING LEDGER (RE.- PLAN FOR SIZE AND ATTACHMENT) INDICATES SHEAR WALL PANEL (RE: PLAN FOR SPECiFICATIONS) INDICATES BRACE WALL PANEL (RE.- PLAN FOR SPEC I FICATION OF OR _kOR JO�ISTS; dLING TO FERMEDIATE "AMING .MBERS�. X L SPACING �iR ROOFS iR FLOORS it uj uj cn LU -t U_ uj to U_ Lu z cc z z cc cc U_ LU co co U) uj I PARTlAL ROOF OR FLOOR PLAN 3 (UBLOCKED DIAPHRAGM) LEGEND STEEL BEAM LVL BEAM WOOD BEAM JOIST/TRUSS SPAN (BEARING CONDITION) JOIST/TRUSS EXTENTS JOIST/TRUSS ( 'FLUSH CONDITION) CROSSHATCHING INDICATES OVERFRAMING (RE: NOTE #7) CROSSHATCHING INDICATES BEARING WALL (TYP. U.N.O.) INDICATES FRAMING LEDGER (RE.- PLAN FOR SIZE AND ATTACHMENT) INDICATES SHEAR WALL PANEL (RE: PLAN FOR SPECiFICATIONS) INDICATES BRACE WALL PANEL (RE.- PLAN FOR SPEC I FICATION OF OR _kOR JO�ISTS; dLING TO FERMEDIATE "AMING .MBERS�. X L SPACING �iR ROOFS iR FLOORS it | | | | | | | � | | _J -- | | | | | || | | | | | | | | | | | | | �------------ || (09 000 D W LO 0 Icin Level Demo -Plan Main Level ro osed Pjar� L"Ta- ITZ "IT I "I", mr, Project #1620 WA--Nlk M k- MA L J� 9C99"06C`OL6 woo"olewidsoi njs 4 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: S L-,� Job Address: 3 4,9 cD A - ► So k ► _ Permit Number: & Q ) %-, �!) O 13 La Vo C- 0 ❑ No one available for inspection: Time 3.3 D A&P Re -Inspection required: Yes No *When corrections have been made 11 for re -inspection at 303-234-5933 Date) Inspect DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Remodel PERMIT - 201601961 PERMIT NO: 201601961 ISSUED: 12/22/2016 JOB ADDRESS: 3690 Allison CT EXPIRES: 12/22/2017 JOB DESCRIPTION: Remove load bearing wall and creating vaulted ceiling area in the living room. Reroof 20 sqs. *** CONTACTS *** OWNER (303)912-6867 GRAY PROPERTIES ALLISON LLC GC (720)298-8446 Kryzsztof Nawalany 160269 Global EPC Services Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 25,000.00 FEES Total Valuation 0.00 Plan Review Fee Use Tax 287.33 450.00 ,, CC tg0;30 Permit Fee 442.05 _ j� �i ** TOTAL ** 1,179.38 *** COMMENTS *** *** CONDITIONS *** BT: Approved per plans and red -line notes on plans. Must comply with 2012 IRC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.All roughs to be done at Framing Inspection. I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performe and that all wok to be Performed is disclosed in th' document and/or its' accompanying approved plans and specifications. Signature of OWNER or ONTRACTOR Oircle one)Date I. This permit was issued based on mation provided i he permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any applicableecod,q orQany ordinance o%regulation of this jurisdiction. Approval of work is subject to field inspection. Signat e of Chief Building Offi is al' ( I Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINEW DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. ( itv of fWh6a-tR,jdgc OMMUNII7 DfVLLOI'MLN f Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits ci.wheatridge.co.us FOR OFFICE USE ONLY ('j Date: Plan/Pe—,v# 12—L (� ( 19 j Plan Review Fee: 2 �� Building Permit Application * Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. I Property Address: 3(5�) O ,4 GIS0N Cil` Property Owner (please print): (5:!rR,4 Y RR OPA!F:eT/ES Phone: ,707 9/Z - (5,Y6 % Property Owner Email: Mailing Address: (if different than property address) Address: 2-G02 k) 0 4 -1-H City, State, zip: ttiy g RD 2 /Af ArchitectlEngineer: ledf: >V Architect/Engineer E-mail: 1�G2 !S a� Kt34J FaU5 -Phone: 720 C0/7 Contractor: 6:G6W,4 L 6•p c Contractors City License #: Phone: Contractor E-mail Address: <<e,!S 0 ),-%OAS) ,6"G . C 0/-07 Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE 9 ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING COMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc ) //V 7-,E'12/042 6e-,5/�70DCG To C Ar V,4e f G. T�=- o 11�i/,67 7-H C G/ k- /iV d- 4e--),0 /'7 ,4 Al ie i71e t- Sq. FULF Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER)(CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) / Electronic Sianature (first and last same): DATE: ZONING COMMMENTS Reviewer. BUILDING DEP-4.RTMENT COMMENTS. Reviewer: I/—� DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION, Building Division Valuation: $ N I O _ N I N X M O 9'-4" to 8'-0" N F1 ND n > -n -n -n 0X0 N X 46 X N 00 GZjODO M WALL NX_Z N \ D z0>x > II" My r C) I" ;;u MONS o O o 46mDN C-) NX X Tl Z U) 0 �� T1 M 0"M> M 0 M D Z�Ov 0 N 41b D= z MZm �M N G -i Mem D 0Z N M� M F- D D n N z O N I O _ N I N X M O 9'-4" to 8'-0" 7'-6" N N N 2X6 WALL ON TOP n 0X0 N X 46 X N 00 OF MASONRY WALL IN, 4h, N c�1 j x r I II" My = v I O 0 Z o X Mo X Z N Z N �� >> n� M 0 M mr -Ihb 0 N 41b D= 20 5 0 N Z N O N D D M� M M� M� N �0 O m ocn �y haODDU N r�O m� m� N0 o ®� z ZZ X Z ®s N ZXrr X NOD �)� `� v 0 OZ O QCOZO �o z Ca �a CN N O O ZO O r 1 I rn 0 0 m rn >o X v D D v Zm En 0 �11O O .. O c Z c cc) �- ,�. co M to to m O O O O � D in m m to 7'-6" N N N ID: I n 0X0 N X 46 X N 00 r M O 20 C N IN, 4h, N c�1 j x r I II" My = v I O 0 Z o O Mo Z N 24'-10" ^Z M0 ^•Z ^•ZOn ID: On mo 52 E i e_% C_ 0 Oo r N MM � O rn-5z=n n rn O ZN My (n --I � ; 0 ODxIm Mo Z N Z N Z N �� >> n� M 0 M mr _n D= 20 5 0 N Z N O N D D M� M M� M� ^0 �0 O m ocn �y m� m� N0 my z ZZ �� �� �v `� v �o z Ca �a OZOZ D� ON 4 n ITl Zm (n Zm En .. i z _ � D M I I N X O D O I 0 X � to I N o M s X Z o n m v c o ;o R I m rn � � M 0 M M M z 24'-10" rN o�cnMZK0 �p rZ 00 s0C) DNoo8 gm �C moil n' DO to OC to � z m N m__cn_O corn MM14M N Z��m 0 rnc�cn� w M NDS � 0 mo>__Uwo� _U>�0�0 -uwD 4M- mom -p Cn�mD -<wm D "Om � 0 C)»�C7wZPMT ONS M 02. (Oo cn-Oco-p��mv(��' ww3;;Mm MM-,IrrnDtnMD �DmwO-<NN- ON) -u' z mM. pcnrn cDn' Z' z' r0 Z �ZnWO�zN�c�y�z o -N Zm �-iX� ZO Z MM. Z �nm X Zz� M' mom Mz- Y) -Dwz . _ tn. O �O�• �pITl21*1COZ' rTi XD -00' 0' NZO ��• MITI' O oDD�rnm O to N 0 MD D ton -1 D DrC D (� Dn 1 OM>O-0 MMOO - <_ Oy -n - D� v (7 �c D n tn�tnND_n � DMmmD (� C)= r—stn Opnp00 D = O\ =O Z� Cn z��00z W� M��- x� m D OZr=� M r0M Z�0 w—IMM -40 ;U000mr orrn z �rOn �� O ��� Mrmrm-nflo= nt�n�ON =oOcZz�O�m=n�c rvrmOvrjO<O �=iXx;d rmr 00 M My Mwr-Q z ooN to v D 0 v y� C7 m om_MNNm� vonm=v�vnnvv n�0 n Snow mncmn �m� n rrn m=�nD�DZ� O = Mme- D� cZnOQZo(��vmD2MM2DwmOND�zvv p�nn p��n OOZN� Cir Mr v cnD D Z �D(�m p n nrM 0 Z)- U) O. �mD�v���n O O Opr� z c M O DM->M m�Z �M �D� N �DNCNmM�oo�Z�O v- 0Z Z ZZo�O D Mrn<v mZ Z O N Ov � O O Z Z O nm�DZz�m v?DM= Oi Z Z M MOD G7 -z Z Or D ENDO Mz O �Ztnm Z��Omm v.. v Z Om Op Myp0 00 m �D OrTlMM vv v � �`2Z C7 � n�N C7 m O-<OrrO �� O:E MMM N 0 Z ZMcn Z0Z N z rr-ZZmw-n-4z D 9DOo2 z0 �O D to rOr� o MD 0 �mZcn XX OZ <r� mini - Z < C7 �n �M-1D-n MMzm � w m wmoc �Ov ND O OC13 r vv_c000 Z CO cn0 N� �_Dcn - �tnn�" y ODO==X N m� 2� � ��N�m Zv m no- r OK'F � z -UM M o m �Nrn �cvxz�mZ ��oror�rI�MN�C c v rn��� =�N z X00 �MMNzyO��� v �r�Trnm�� �vNovQ=mcD��mn M DVDMO DAN O z� mDz� mm= mm O- N M C) X 0 0 m to N mD0 m D �c�0m�n =m�ND�0>. � O M MMS m0 v v m x2 �= rn rZ(� z =- z C nrCn 0 M v v= nrm z Cif) r C �� (nD r o m Z r n-�O-OMO m29C �Z < N D DOS Ozx>mm Mwo N D �r�� O v �Mz m N N Z0 DNO� �ZZ (�: - Cz Z�z < �r i' rn for m � �IpMr0rNr=Z 0 =� m z �Mr�- M M �= 0 0�tnOC�M ov rzp : �m O m oo�aDo m m =vm p Z m_otmnmmDZ� -=<m 0NZr Z z..cn=z= r=� to �Dm O D XrM�-im� z �Z �� 0o�am�rzzN�Ln II II II Mtn -O � o� MZ -Z =<m0 C�pO ITS o- O tn- O M r -;U �O �N C : �� ; �Cx- r to rOZ ZD O�OpM �2mD �DNZ D Z rn�0r nor OZZ r- -0 Cvey v DN -0* MM m mzo 0 M _ m�>5>0 ON OOr p� O m� ; _• D 09-n0 N � r -tel Z m 0Zz • ;q M�m Mp C p to M Or, r OrT. 0 T. �m0 �mzN D ZC�r-O� �Z� �tn0- M��� oma mrDZmm O Nr rn DLn = m N M m N v N p0�� N N < z �Z TZI N o m N Z Z DO�� ZM 0 O D �100D mm�z� Z z�cZn : D m ZG�O y m mZ0 N Ov ZM D Onm D z OC C 2 Z m,Zpj OOT- CX<O 0 000NM mnMr-com20 C 00 Z �r OD Zm=�z z� U)0Z: p; _ Z -n r 0 M>Orl D ;U(n;un(zN� nOOr m�vm r O Zv -u (n M< I M�0 D �c N�� mDtmilN tzn tnC Orn MmxwMMMOw>OM C)M- m zzmr �� vM �00� X: m r �vrr � zoo r W. 00� O�Or D -0O O p O D c ym �mN o U) =i r z =O- v,n5c� •• tnDZM �NmcnM��Xnro� r 00 0 0M �M (� L/) vZ �-i ��r O = Om -<- MOM55r zDzO OmD� rn � X M��M ch 0 < �o Z Z Mommwmmzr Z = rZ C C �; D0 0 r-0 MC D-Dz v�o to 0 v II II tn� O D�0 O G7 nM Z: ^M m mn Z O �NC� O (�O�mm�mz (�ZrO NOO = m p ��O p�0 v mDC� n cn�'0v� �O�m m =-OnvD pcn r�0 n rn�O N O ncZn z rmOvm �N M��':Ex- DO rn m D O Z O orn env �M�z n N� = m Z zrn�� z m �O O �� r MZMv DMrnz cn�rzn�O�m�� �w n0 == z� n=�M rMMM D v is 0: _ o -n�N-n o r Z M MO 00=mM �v> 0�M-v M N O-� �� �Z Z DDD N N = O rn� o i m y m-px r (� rel' Mcn; O: M O M p -0M M Zrny - O DC- to Nr M Mcmm-mo pN � �_�� r rn� M to N I n m cn�v m -� NM Mm�m M� vz �z- rM D n<mT.M O M Z: X N 0MM0 0 O W X r N `LO v v D DM � M O MM 00 0 OMM mOcm 002 �� m0 2 zr O 0 Z� mm (,+ y: M p;u z� M 0 i � X z�IT� Dz�m^ D�cm ODS z = O � ZOz M3' w mo X (��(n C�mM D -ON Mm0 MMw0-Z50 tntn O> �MO M 0 M� � z<�' o \nom N m M _ 11� M �OI� OCMn� CMZ vmM O z O v�v� O zoom D z z z mwzmrDVNDN mm - m m v Z=OO MMcn: mm�zv cn v=: O. M "=MO �m �. = r m per. 0 p v �� p M � O M pCzMM �W m:OO`t M X Z ZO <m�D2 c7n o 0 MD �CC 00 N M�Orntvnrn MD Om M� Mr � M y r z Ln O 2' O OD 0 p v �� ��� �W�z CO Z0m Z �M 0rD XD <� MN �M� � � M �O D O � ^O Zz�z�p= X = m �� D m :E O z y 0 -ICM ��M m = m m�-0 om -D D Oct _ �2gEo -0 M m --1 -n =- �- vM - �_ M yr;0 c�vr I �N N � rD O C n � N�0M>NM-< zozz <DO� x O n 0M;u Z N N r D =MZ Dr z 2zZpmC7.Zo7ClTl �v �D = ON Om M _ - rT� rtn M 50C r �v M C= N C N � O _ = r n Ozm mv0� v �= pz �. M �o Mme_ �O m -m - D D� MZ D X (� ADO D NNn NO D C MO m Mtn 8 m Z -y -Dm\ (n --I M-0 Z m �m oo M- m r -< D N 0 r�<OMz� MZ MO z M< Z Oz O' no �z mvrn^'- o D N - D N m m -<n Jmnv D��� �Opz N D M 5OmvO -dO r O w ��rM D z r MC�tn=�c MM cn Z> DN =C0 1 n ZM Ov � N O m? D yn rn D N m m�ZODt��� cn�M0 D 0 O z� rmmn m� m n O=ff z ��[*1 n� = ONr- ;U OM �m Z 0 O zM mzmz n _ M 2 Z M Z Z OD Zm Cc D �O G�Zr p��m O= O- �D n ccm c r N�Ln I r p00 �=MN mry M oo v N Oma m m I 2 c�0�r z rn *O z z n>0> Z �v Ln N z -- DC) y M D <- D C)Op-SOD C ov OZO� U ZD O rrn z c : M o OD O ..z ?IN' v� 0- C z ��� =0 cc DD p C v cn m M" ��� �O z Oz M M ��ZO �M v �z zmv N �v M 2�m M z M -Mo 7-1 ��� D O� �v z O N � Or X� M M M^� 0 Do• = W = Z_ =M N m mc -n M Mm D ZZ 0 Z O�fnOn � � � M nC7 �mrn0 N^y (n= W D �� Dv y v z n C�<zM�� NzvcXi �m \Z -n O z m �o n N - -Dp0 M r-NZ r,Dm vv O • ymo zD��ZOz -j r MO El rvND n �r Z N NII m N" v 0 �ONVONm Z0 -d CM z Z� z o 0 OM N �X M0 or D C ��=j M zNVM �N 0 U)N MM 0 00000 � � Z rn �v MpOp� n- N �O v .= v z�- TI -N O - =N v 0 C)- n O M D- N Dw NO m? O �o o < = M ��zODO� nMN� Z �m = M Z Z ccn -N O r ry ZZ -I q On�I*m1 MM C �ZOp NO=2zm y N D z n0 vmi 2D stn r NT. z D co00 `� C= = 0 � D v O N �N D N m Z O = z=�M tn0 O MOyz 2 z-m-Nj� � r n� MZ MOO cn�>� M= O v^ 0 r -<CO"jM=�I �0�� X� m m O C= C)Z M 0 Z Z IM --I OM Zr 1;0_n M�ITIM0N�M D = v V) 0 OM =r0 M i D. � �O G7 O X -0 m nn m � _ � �D ON stn Z 0 ZOOm� Dpr�cN r -i X �M MMZz N 0N� N v orn M O O�vOND�r� v� N N <r Z � 0 r -r m� 0 O cn�10� Np N tnD�� DZCOC.dz r � p� �-zD M D G7 .. O zv�m� ink D� D O M mm D� v v MO,� zC� _ zoo Tlcn�mnZ� _ - _� Co O r m D N q zM � M z m Ox D Mo 0 C. � D O m v t7 En Z x r C,i0 MMO zr N to O D D r M o M N rZ N �O r n KM = X = z ch M �OPo m D2C cn n m m>v = Z r N N v Mn C r0 to C r m zCM�M o m v- L N vO 99Z Z N N r= O m mM �c X m m2 C 2M C7 O = --i = - 0 M m v rD� to I Zy O O z MN m°D m MO m ON O p Z m �_ ZO m Mp ^ _ r r p �0 �n v X v� D Z O > _ = m N m i � Z = N z to cn 0 m m to M 0 z r m z m M M > cn m M 0 mNDNrn�NDN��I 2 N t7NCCn NNS �:O�j� rnD--D -w- OZC 0-0 w BIZ Z>--00Mw-UM-4Mo OOMMMWOOMMMOO �02mK�_1C)�0OMwKw>0"* Z W"- ;0rnncncz�-VwM� m N Z-Z� oCr coDw�Irn m�tn�� c,+m!v ODZ ��\\OD Dzor• x• gym' m' OOOmp�OOOMOM' moomo* MOM000mp• KC' m N -Iw v r 0 �� OM. M M OFO OD M �r r0 C -0 Or, M KKMZOCKKMZVN ZKMZO ZKZKKMZO MM N -vz 1 -AOrDOOoow ��D ";U O MMMMM MOMM ;rM m0� cn� " --I -v I�TI2�Zom�cmmmm o 00 -0 ���Oz�OmmOZr-zM OmOZrMOmOmmOZr—MOMMA n Di0 zy�rrD-< 0 O \ II II = G7� rnt'I�Dzoz N O< CD y O OD000 Ovz00� Oz0 Z°D ��_ mN �D m�0__1 wow-ww C O O - Mww__1 w NN�ON0< zW__j M< NZNN�oNOz�OZ p OOO ZmN�C r0�0 v �v O y v�vvv m vv0 ODO OD ODO 0= �r�Nv�Mcn-��� _ - "O �NND(n ONNyN �� cn�Dcn vtnN�I�ODcn 00 -WO Z v Moorr MDO� --I x M prn m c \\< _ rnOn�� _ -1 -1 -i O--r-jO r-jo-M �-r-jOm�-D--r�OMz�Mc 0' m m � M mmm N*MM- m M m D 00 m00 M O O 00 O "1 Omz Z m _ M z w - N O mr Mm D �D-iyX0 O O O� mZZ Z7 TI ZZ mrnm MZ ;UMM;00 zz �m cnM 7, Co � 0 �Cv Z m v F c \O�NO� r -> (no co -u> p- mDo zr �OZD yz(n��r=rI� I rn =cmnm= =cmnm-= tmn xwMKcmn m =crnnmodc� m c DSD Ctn � 0�0 = m M Mr rM r�r �Z v� m O�000 r -O M O tntn Mtntn Dm �N tel; U) U) r�-�m m v�M ��mm=� X W r -NC Z � v mZrDD D 00 O =��� N N N (7N N �1 Zm "jM�MmO � v z ram m Oz�Ooc ON�p �O m m =M D NJO �-vN�Q 1 I I_ Mmm� ��mm� Ln -0m�. cnp D: MwM-j02 ' 000 �: N I �: N Mme: N0�M. MM�NcnMMnZ D G7 --I OMMMz cn = Z N m r o r- [�[**11 tn<4 000 v i=cn�Cvov�cmc0 O O M -n D DM: mm :- --I c �MN�2Dzp 0 m 00om z m_U 0 TODD �M0 ww 0- z Zm=W�CC�O�Or s s : NNcn: n�NNcn: () ANN: n �� i NNN: C7 � --i -n ;OC(n Otnztn-MZO� C r to vC 0 OpOrn On��m C7 2� CC Z= 0 rrm�mN��rm� �: �: r �: 4MF: : M: 4 -nzO-i� C:> =-=n vz M M tn� r I c)Zz00 - �� =mom �Z Wv m tnNr- z -TI C��M: cn��M: rim: fir: ��M: = 0 mrr zDMMWN My Zr, m OIn =�� 00 i r0Wn Nn. D �mo -m0 MDN: =MDN: : NMDN: M. MD r yrcr. -oma Co 0 0 v Z D N=0� mD� i-rn NO gym. � �O���O ^ 0�'ON: M��N: : r -;U yr: : ;U;0LfI: y�mzm m En rr� O�=fir m 0 m O Z. N� rw= Dnp mi Cm M Dnp m�� v �D; r�D; N D; �D; : ; mi a) -nR0 zm0mDO� r v cn D m v m m00 zzOz 2m� m� �O zp �p0 ZZD M>O;U I N N DZ� j: (n0M; Om; v0' zm; mv�55cncmi� 0 zzz G�m'��-0z O C O; v Or * = 0 cncn0 voo� �oZ ON �z mz _v Iv 0�m O�0Orn x � ++ rnr: "10 0 0r: Ko. C)r' �0m�m � No tnNcn� N m C N � MM M_j� ���= UP 0 ^OZ U) D O�0 DCN � En C: (nC�: Mme: rnD: Com: MpKC� --I m0� NM(Mn��n N m z D w z 0ND ODDm n DC O0 ND �z� �0D �mmn N =�o. o. � zo. mz: -O: Mzz�Z O �ZM zcnDCm v 1 C M -I i C Dcz C�rOo = o mz zr 2D� -z Lf) m;0: �0: r- : 0: ,,,: ;a 0: M --I u) * r- __j tn0CrZ� m O M O p M ZZv �Orp Z mm �r ON __ G)00 40 _ _ O�D� rn�D� D �� �D �� DO r=,, CICO 0mm• 0 D ,� TI r vv Nr Z N OZ M -n -0 Z -M MM rn C! C:--IOp � : tn. O cnC0F OM cpm I Z Z . p m O Mm MO�� n M NN �� M -v D� mM M s0 = r Z: r z: R : Z: Z: nrn v 0 Dmf Z� �M M v � o D 0 M =�0 mmmv O w �M v� 00 � 0 r Dn = 'M0, r00, m : _ o. �� C c;Mx Oma IT10 N to N �I =Z C -V-1 ZOry Z O 1 D NNW - p0 Mme M DO-vmO O O O �; ��: M : �. D: -n-n; : -n >OZK� � ��M Dp C N x m N �y �� �I -� C" \\� 0v- C1 0 0 M. t7 (� D; D; : = M-1' 00>' mm�zMm0 rtn� z�� ON r C z X c MDO Nin N �O z N mm pD�o. n . z: �mOz: �� SO11 N II tn� II II zn II II SMO m c=M vNM �M n v rn v nr- p�0� I N v� - MZ Zvi _ _ _ _ II 11 II II M II II ha OD. > II �� II ���yzZ�c � MDQ (� D N Z m n � z M 0= _n m v M -9 OD O O O M"jO D C7 r- -n v >y O v N O D N zM mOz� D �• II II �= (Mno �M��?I ?� �'� nn II °'�Mnc� II w� ao�cnootnOCnCn 0000- r�� to m mmp zK Dv D n r C Mrtn ren O M !�N -v (n w mm _v z D ONo0 N II II CJ�,L"00) II 11 Ln00 14 0 CA m U'0 0:0-0� O OON�rn�N y �c�M M� �Z I D r Z M v D-vM o=ff D oo N rn m0!�1 O Z<m�z z Z �� 00�� O ;0 O -U�O �N(n mm0� OK N� p0 m Z v N N �_ Zy� DMO N _n N� M-\\ p 0 MMNO p O C 00 -am- z00mm- to ONO to-- Nyp-rOmD Z OZM - Z N D r Z0;0> ZN � 0 D v tn(no m NNO ��--pm --p MN v �Z MtTIN �D \O C7 � r D 0 =�� r�N 0 OM -d Oz O r z0= O M wcoc" N 00 0--0 cncn O N cOcmilc�il0 �0N C)q Z M U S C 0 0� Z z Od I � M O m- z M� N 0 -v� �� _ �r mr<� 0 v =m � dw o0 Z N N 0 D v N MOO �ITI� D -n Zn Ozz M mvm-v M NN ��NN _v - NO NOM �. MM �z� 20 0 0O 0 y Z z NZ = NSM w O =y Nm z c z m m -nm v Nm N = -zMa^M ��m DpM zN N Z z o z v otnp U) OJ G7 Mr v O m c nz�� m y O Oz 1-4 D No -V -n C N c m z r n M O cci�mm D D C� 00 m ��N N rmrmz v pOCOD z �__ N� DN v z i m 0 M O K MOO Z ^ Zn Cz D �G>m Z M OC O to M M 0M"o 0 M M ir- ( zD N i z D Z= Z m D M_n. v o� Cu� �00� p Zm N cnD O "i Or 2 m r O O X I C7 = z �r Mm Z (nm 0 M m z z�N� C Nco �D D N = _ vM O �M C 0 0 <� =tn r o z 0co = 0� O� � c o� r v CO m �C_> m 0M M 0 Opp M M0 D�O Cm O z C= w m m 0 2 O M Z tmi� D m0 �� x DO* y m r -Z 0 r M M290 N CZD zmM �D C M n z m O r cC tnD �Zz Z z Z� 0 -D= M ��� p z stn N m= v Z M 0 = D o�CZ D Ngo y o DM z ; �U) z m m -V -v v y N �1 y Z O N v Z r2 C � r � � x N �D tnN O D" Z 0 -y -y Z Co cn = � m� v = m v r r -v ROOF FRAMING MOD I FI CA T ION CVz TO Z Z -n ZZ SINGLE FAMILY HOME m � �� Z 3690 ALLISON CT O WHEAT RIDGE, COLORADO KPN Eneineerin! LLC Structural Engineer 23651 E Easter Dr. Apt. 208 AURORA CO. 80016 Tel. 1-(720)-298-8446 12/7/16 z D DATE ID: 0 Z M x PLOTTED: USER: M °' MMMOMDMD O -v C� D X o M � O rn-5z=n n rn O NO���D r0 0 F 0 p v Mo rN o�cnMZK0 �p rZ 00 s0C) DNoo8 gm �C moil n' DO to OC to � z m N m__cn_O corn MM14M N Z��m 0 rnc�cn� w M NDS � 0 mo>__Uwo� _U>�0�0 -uwD 4M- mom -p Cn�mD -<wm D "Om � 0 C)»�C7wZPMT ONS M 02. (Oo cn-Oco-p��mv(��' ww3;;Mm MM-,IrrnDtnMD �DmwO-<NN- ON) -u' z mM. pcnrn cDn' Z' z' r0 Z �ZnWO�zN�c�y�z o -N Zm �-iX� ZO Z MM. Z �nm X Zz� M' mom Mz- Y) -Dwz . _ tn. O �O�• �pITl21*1COZ' rTi XD -00' 0' NZO ��• MITI' O oDD�rnm O to N 0 MD D ton -1 D DrC D (� Dn 1 OM>O-0 MMOO - <_ Oy -n - D� v (7 �c D n tn�tnND_n � DMmmD (� C)= r—stn Opnp00 D = O\ =O Z� Cn z��00z W� M��- x� m D OZr=� M r0M Z�0 w—IMM -40 ;U000mr orrn z �rOn �� O ��� Mrmrm-nflo= nt�n�ON =oOcZz�O�m=n�c rvrmOvrjO<O �=iXx;d rmr 00 M My Mwr-Q z ooN to v D 0 v y� C7 m om_MNNm� vonm=v�vnnvv n�0 n Snow mncmn �m� n rrn m=�nD�DZ� O = Mme- D� cZnOQZo(��vmD2MM2DwmOND�zvv p�nn p��n OOZN� Cir Mr v cnD D Z �D(�m p n nrM 0 Z)- U) O. �mD�v���n O O Opr� z c M O DM->M m�Z �M �D� N �DNCNmM�oo�Z�O v- 0Z Z ZZo�O D Mrn<v mZ Z O N Ov � O O Z Z O nm�DZz�m v?DM= Oi Z Z M MOD G7 -z Z Or D ENDO Mz O �Ztnm Z��Omm v.. v Z Om Op Myp0 00 m �D OrTlMM vv v � �`2Z C7 � n�N C7 m O-<OrrO �� O:E MMM N 0 Z ZMcn Z0Z N z rr-ZZmw-n-4z D 9DOo2 z0 �O D to rOr� o MD 0 �mZcn XX OZ <r� mini - Z < C7 �n �M-1D-n MMzm � w m wmoc �Ov ND O OC13 r vv_c000 Z CO cn0 N� �_Dcn - �tnn�" y ODO==X N m� 2� � ��N�m Zv m no- r OK'F � z -UM M o m �Nrn �cvxz�mZ ��oror�rI�MN�C c v rn��� =�N z X00 �MMNzyO��� v �r�Trnm�� �vNovQ=mcD��mn M DVDMO DAN O z� mDz� mm= mm O- N M C) X 0 0 m to N mD0 m D �c�0m�n =m�ND�0>. � O M MMS m0 v v m x2 �= rn rZ(� z =- z C nrCn 0 M v v= nrm z Cif) r C �� (nD r o m Z r n-�O-OMO m29C �Z < N D DOS Ozx>mm Mwo N D �r�� O v �Mz m N N Z0 DNO� �ZZ (�: - Cz Z�z < �r i' rn for m � �IpMr0rNr=Z 0 =� m z �Mr�- M M �= 0 0�tnOC�M ov rzp : �m O m oo�aDo m m =vm p Z m_otmnmmDZ� -=<m 0NZr Z z..cn=z= r=� to �Dm O D XrM�-im� z �Z �� 0o�am�rzzN�Ln II II II Mtn -O � o� MZ -Z =<m0 C�pO ITS o- O tn- O M r -;U �O �N C : �� ; �Cx- r to rOZ ZD O�OpM �2mD �DNZ D Z rn�0r nor OZZ r- -0 Cvey v DN -0* MM m mzo 0 M _ m�>5>0 ON OOr p� O m� ; _• D 09-n0 N � r -tel Z m 0Zz • ;q M�m Mp C p to M Or, r OrT. 0 T. �m0 �mzN D ZC�r-O� �Z� �tn0- M��� oma mrDZmm O Nr rn DLn = m N M m N v N p0�� N N < z �Z TZI N o m N Z Z DO�� ZM 0 O D �100D mm�z� Z z�cZn : D m ZG�O y m mZ0 N Ov ZM D Onm D z OC C 2 Z m,Zpj OOT- CX<O 0 000NM mnMr-com20 C 00 Z �r OD Zm=�z z� U)0Z: p; _ Z -n r 0 M>Orl D ;U(n;un(zN� nOOr m�vm r O Zv -u (n M< I M�0 D �c N�� mDtmilN tzn tnC Orn MmxwMMMOw>OM C)M- m zzmr �� vM �00� X: m r �vrr � zoo r W. 00� O�Or D -0O O p O D c ym �mN o U) =i r z =O- v,n5c� •• tnDZM �NmcnM��Xnro� r 00 0 0M �M (� L/) vZ �-i ��r O = Om -<- MOM55r zDzO OmD� rn � X M��M ch 0 < �o Z Z Mommwmmzr Z = rZ C C �; D0 0 r-0 MC D-Dz v�o to 0 v II II tn� O D�0 O G7 nM Z: ^M m mn Z O �NC� O (�O�mm�mz (�ZrO NOO = m p ��O p�0 v mDC� n cn�'0v� �O�m m =-OnvD pcn r�0 n rn�O N O ncZn z rmOvm �N M��':Ex- DO rn m D O Z O orn env �M�z n N� = m Z zrn�� z m �O O �� r MZMv DMrnz cn�rzn�O�m�� �w n0 == z� n=�M rMMM D v is 0: _ o -n�N-n o r Z M MO 00=mM �v> 0�M-v M N O-� �� �Z Z DDD N N = O rn� o i m y m-px r (� rel' Mcn; O: M O M p -0M M Zrny - O DC- to Nr M Mcmm-mo pN � �_�� r rn� M to N I n m cn�v m -� NM Mm�m M� vz �z- rM D n<mT.M O M Z: X N 0MM0 0 O W X r N `LO v v D DM � M O MM 00 0 OMM mOcm 002 �� m0 2 zr O 0 Z� mm (,+ y: M p;u z� M 0 i � X z�IT� Dz�m^ D�cm ODS z = O � ZOz M3' w mo X (��(n C�mM D -ON Mm0 MMw0-Z50 tntn O> �MO M 0 M� � z<�' o \nom N m M _ 11� M �OI� OCMn� CMZ vmM O z O v�v� O zoom D z z z mwzmrDVNDN mm - m m v Z=OO MMcn: mm�zv cn v=: O. M "=MO �m �. = r m per. 0 p v �� p M � O M pCzMM �W m:OO`t M X Z ZO <m�D2 c7n o 0 MD �CC 00 N M�Orntvnrn MD Om M� Mr � M y r z Ln O 2' O OD 0 p v �� ��� �W�z CO Z0m Z �M 0rD XD <� MN �M� � � M �O D O � ^O Zz�z�p= X = m �� D m :E O z y 0 -ICM ��M m = m m�-0 om -D D Oct _ �2gEo -0 M m --1 -n =- �- vM - �_ M yr;0 c�vr I �N N � rD O C n � N�0M>NM-< zozz <DO� x O n 0M;u Z N N r D =MZ Dr z 2zZpmC7.Zo7ClTl �v �D = ON Om M _ - rT� rtn M 50C r �v M C= N C N � O _ = r n Ozm mv0� v �= pz �. M �o Mme_ �O m -m - D D� MZ D X (� ADO D NNn NO D C MO m Mtn 8 m Z -y -Dm\ (n --I M-0 Z m �m oo M- m r -< D N 0 r�<OMz� MZ MO z M< Z Oz O' no �z mvrn^'- o D N - D N m m -<n Jmnv D��� �Opz N D M 5OmvO -dO r O w ��rM D z r MC�tn=�c MM cn Z> DN =C0 1 n ZM Ov � N O m? D yn rn D N m m�ZODt��� cn�M0 D 0 O z� rmmn m� m n O=ff z ��[*1 n� = ONr- ;U OM �m Z 0 O zM mzmz n _ M 2 Z M Z Z OD Zm Cc D �O G�Zr p��m O= O- �D n ccm c r N�Ln I r p00 �=MN mry M oo v N Oma m m I 2 c�0�r z rn *O z z n>0> Z �v Ln N z -- DC) y M D <- D C)Op-SOD C ov OZO� U ZD O rrn z c : M o OD O ..z ?IN' v� 0- C z ��� =0 cc DD p C v cn m M" ��� �O z Oz M M ��ZO �M v �z zmv N �v M 2�m M z M -Mo 7-1 ��� D O� �v z O N � Or X� M M M^� 0 Do• = W = Z_ =M N m mc -n M Mm D ZZ 0 Z O�fnOn � � � M nC7 �mrn0 N^y (n= W D �� Dv y v z n C�<zM�� NzvcXi �m \Z -n O z m �o n N - -Dp0 M r-NZ r,Dm vv O • ymo zD��ZOz -j r MO El rvND n �r Z N NII m N" v 0 �ONVONm Z0 -d CM z Z� z o 0 OM N �X M0 or D C ��=j M zNVM �N 0 U)N MM 0 00000 � � Z rn �v MpOp� n- N �O v .= v z�- TI -N O - =N v 0 C)- n O M D- N Dw NO m? O �o o < = M ��zODO� nMN� Z �m = M Z Z ccn -N O r ry ZZ -I q On�I*m1 MM C �ZOp NO=2zm y N D z n0 vmi 2D stn r NT. z D co00 `� C= = 0 � D v O N �N D N m Z O = z=�M tn0 O MOyz 2 z-m-Nj� � r n� MZ MOO cn�>� M= O v^ 0 r -<CO"jM=�I �0�� X� m m O C= C)Z M 0 Z Z IM --I OM Zr 1;0_n M�ITIM0N�M D = v V) 0 OM =r0 M i D. � �O G7 O X -0 m nn m � _ � �D ON stn Z 0 ZOOm� Dpr�cN r -i X �M MMZz N 0N� N v orn M O O�vOND�r� v� N N <r Z � 0 r -r m� 0 O cn�10� Np N tnD�� DZCOC.dz r � p� �-zD M D G7 .. O zv�m� ink D� D O M mm D� v v MO,� zC� _ zoo Tlcn�mnZ� _ - _� Co O r m D N q zM � M z m Ox D Mo 0 C. � D O m v t7 En Z x r C,i0 MMO zr N to O D D r M o M N rZ N �O r n KM = X = z ch M �OPo m D2C cn n m m>v = Z r N N v Mn C r0 to C r m zCM�M o m v- L N vO 99Z Z N N r= O m mM �c X m m2 C 2M C7 O = --i = - 0 M m v rD� to I Zy O O z MN m°D m MO m ON O p Z m �_ ZO m Mp ^ _ r r p �0 �n v X v� D Z O > _ = m N m i � Z = N z to cn 0 m m to M 0 z r m z m M M > cn m M 0 mNDNrn�NDN��I 2 N t7NCCn NNS �:O�j� rnD--D -w- OZC 0-0 w BIZ Z>--00Mw-UM-4Mo OOMMMWOOMMMOO �02mK�_1C)�0OMwKw>0"* Z W"- ;0rnncncz�-VwM� m N Z-Z� oCr coDw�Irn m�tn�� c,+m!v ODZ ��\\OD Dzor• x• gym' m' OOOmp�OOOMOM' moomo* MOM000mp• KC' m N -Iw v r 0 �� OM. M M OFO OD M �r r0 C -0 Or, M KKMZOCKKMZVN ZKMZO ZKZKKMZO MM N -vz 1 -AOrDOOoow ��D ";U O MMMMM MOMM ;rM m0� cn� " --I -v I�TI2�Zom�cmmmm o 00 -0 ���Oz�OmmOZr-zM OmOZrMOmOmmOZr—MOMMA n Di0 zy�rrD-< 0 O \ II II = G7� rnt'I�Dzoz N O< CD y O OD000 Ovz00� Oz0 Z°D ��_ mN �D m�0__1 wow-ww C O O - Mww__1 w NN�ON0< zW__j M< NZNN�oNOz�OZ p OOO ZmN�C r0�0 v �v O y v�vvv m vv0 ODO OD ODO 0= �r�Nv�Mcn-��� _ - "O �NND(n ONNyN �� cn�Dcn vtnN�I�ODcn 00 -WO Z v Moorr MDO� --I x M prn m c \\< _ rnOn�� _ -1 -1 -i O--r-jO r-jo-M �-r-jOm�-D--r�OMz�Mc 0' m m � M mmm N*MM- m M m D 00 m00 M O O 00 O "1 Omz Z m _ M z w - N O mr Mm D �D-iyX0 O O O� mZZ Z7 TI ZZ mrnm MZ ;UMM;00 zz �m cnM 7, Co � 0 �Cv Z m v F c \O�NO� r -> (no co -u> p- mDo zr �OZD yz(n��r=rI� I rn =cmnm= =cmnm-= tmn xwMKcmn m =crnnmodc� m c DSD Ctn � 0�0 = m M Mr rM r�r �Z v� m O�000 r -O M O tntn Mtntn Dm �N tel; U) U) r�-�m m v�M ��mm=� X W r -NC Z � v mZrDD D 00 O =��� N N N (7N N �1 Zm "jM�MmO � v z ram m Oz�Ooc ON�p �O m m =M D NJO �-vN�Q 1 I I_ Mmm� ��mm� Ln -0m�. cnp D: MwM-j02 ' 000 �: N I �: N Mme: N0�M. MM�NcnMMnZ D G7 --I OMMMz cn = Z N m r o r- [�[**11 tn<4 000 v i=cn�Cvov�cmc0 O O M -n D DM: mm :- --I c �MN�2Dzp 0 m 00om z m_U 0 TODD �M0 ww 0- z Zm=W�CC�O�Or s s : NNcn: n�NNcn: () ANN: n �� i NNN: C7 � --i -n ;OC(n Otnztn-MZO� C r to vC 0 OpOrn On��m C7 2� CC Z= 0 rrm�mN��rm� �: �: r �: 4MF: : M: 4 -nzO-i� C:> =-=n vz M M tn� r I c)Zz00 - �� =mom �Z Wv m tnNr- z -TI C��M: cn��M: rim: fir: ��M: = 0 mrr zDMMWN My Zr, m OIn =�� 00 i r0Wn Nn. D �mo -m0 MDN: =MDN: : NMDN: M. MD r yrcr. -oma Co 0 0 v Z D N=0� mD� i-rn NO gym. � �O���O ^ 0�'ON: M��N: : r -;U yr: : ;U;0LfI: y�mzm m En rr� O�=fir m 0 m O Z. N� rw= Dnp mi Cm M Dnp m�� v �D; r�D; N D; �D; : ; mi a) -nR0 zm0mDO� r v cn D m v m m00 zzOz 2m� m� �O zp �p0 ZZD M>O;U I N N DZ� j: (n0M; Om; v0' zm; mv�55cncmi� 0 zzz G�m'��-0z O C O; v Or * = 0 cncn0 voo� �oZ ON �z mz _v Iv 0�m O�0Orn x � ++ rnr: "10 0 0r: Ko. C)r' �0m�m � No tnNcn� N m C N � MM M_j� ���= UP 0 ^OZ U) D O�0 DCN � En C: (nC�: Mme: rnD: Com: MpKC� --I m0� NM(Mn��n N m z D w z 0ND ODDm n DC O0 ND �z� �0D �mmn N =�o. o. � zo. mz: -O: Mzz�Z O �ZM zcnDCm v 1 C M -I i C Dcz C�rOo = o mz zr 2D� -z Lf) m;0: �0: r- : 0: ,,,: ;a 0: M --I u) * r- __j tn0CrZ� m O M O p M ZZv �Orp Z mm �r ON __ G)00 40 _ _ O�D� rn�D� D �� �D �� DO r=,, CICO 0mm• 0 D ,� TI r vv Nr Z N OZ M -n -0 Z -M MM rn C! C:--IOp � : tn. O cnC0F OM cpm I Z Z . p m O Mm MO�� n M NN �� M -v D� mM M s0 = r Z: r z: R : Z: Z: nrn v 0 Dmf Z� �M M v � o D 0 M =�0 mmmv O w �M v� 00 � 0 r Dn = 'M0, r00, m : _ o. �� C c;Mx Oma IT10 N to N �I =Z C -V-1 ZOry Z O 1 D NNW - p0 Mme M DO-vmO O O O �; ��: M : �. D: -n-n; : -n >OZK� � ��M Dp C N x m N �y �� �I -� C" \\� 0v- C1 0 0 M. t7 (� D; D; : = M-1' 00>' mm�zMm0 rtn� z�� ON r C z X c MDO Nin N �O z N mm pD�o. n . z: �mOz: �� SO11 N II tn� II II zn II II SMO m c=M vNM �M n v rn v nr- p�0� I N v� - MZ Zvi _ _ _ _ II 11 II II M II II ha OD. > II �� II ���yzZ�c � MDQ (� D N Z m n � z M 0= _n m v M -9 OD O O O M"jO D C7 r- -n v >y O v N O D N zM mOz� D �• II II �= (Mno �M��?I ?� �'� nn II °'�Mnc� II w� ao�cnootnOCnCn 0000- r�� to m mmp zK Dv D n r C Mrtn ren O M !�N -v (n w mm _v z D ONo0 N II II CJ�,L"00) II 11 Ln00 14 0 CA m U'0 0:0-0� O OON�rn�N y �c�M M� �Z I D r Z M v D-vM o=ff D oo N rn m0!�1 O Z<m�z z Z �� 00�� O ;0 O -U�O �N(n mm0� OK N� p0 m Z v N N �_ Zy� DMO N _n N� M-\\ p 0 MMNO p O C 00 -am- z00mm- to ONO to-- Nyp-rOmD Z OZM - Z N D r Z0;0> ZN � 0 D v tn(no m NNO ��--pm --p MN v �Z MtTIN �D \O C7 � r D 0 =�� r�N 0 OM -d Oz O r z0= O M wcoc" N 00 0--0 cncn O N cOcmilc�il0 �0N C)q Z M U S C 0 0� Z z Od I � M O m- z M� N 0 -v� �� _ �r mr<� 0 v =m � dw o0 Z N N 0 D v N MOO �ITI� D -n Zn Ozz M mvm-v M NN ��NN _v - NO NOM �. MM �z� 20 0 0O 0 y Z z NZ = NSM w O =y Nm z c z m m -nm v Nm N = -zMa^M ��m DpM zN N Z z o z v otnp U) OJ G7 Mr v O m c nz�� m y O Oz 1-4 D No -V -n C N c m z r n M O cci�mm D D C� 00 m ��N N rmrmz v pOCOD z �__ N� DN v z i m 0 M O K MOO Z ^ Zn Cz D �G>m Z M OC O to M M 0M"o 0 M M ir- ( zD N i z D Z= Z m D M_n. v o� Cu� �00� p Zm N cnD O "i Or 2 m r O O X I C7 = z �r Mm Z (nm 0 M m z z�N� C Nco �D D N = _ vM O �M C 0 0 <� =tn r o z 0co = 0� O� � c o� r v CO m �C_> m 0M M 0 Opp M M0 D�O Cm O z C= w m m 0 2 O M Z tmi� D m0 �� x DO* y m r -Z 0 r M M290 N CZD zmM �D C M n z m O r cC tnD �Zz Z z Z� 0 -D= M ��� p z stn N m= v Z M 0 = D o�CZ D Ngo y o DM z ; �U) z m m -V -v v y N �1 y Z O N v Z r2 C � r � � x N �D tnN O D" Z 0 -y -y Z Co cn = � m� v = m v r r -v ROOF FRAMING MOD I FI CA T ION CVz TO Z Z -n ZZ SINGLE FAMILY HOME m � �� Z 3690 ALLISON CT O WHEAT RIDGE, COLORADO KPN Eneineerin! LLC Structural Engineer 23651 E Easter Dr. Apt. 208 AURORA CO. 80016 Tel. 1-(720)-298-8446 12/7/16 12/7/16 DATE ID: SAVED: DWG VER #: PLOTTED: USER: ISSUE FOR CONSTRUCTION REVISIONS AND RECORD OF ISSUE XREF1 ID: XREF2 ID: XREF3 ID: XREF4 ID: SW: XREF5 ID: 0 M z M Z O N 11.1 to 0 M 0 _1 D O Z to 0 M z M 0 M z M D r Z O N O z M v D Z v C c D r m M M M CD M M to 0 KN KN KN NO. BY CK APP FOR OFFICE USE ONLY City of t PENT74`g "on Services Division -00 7500 W. 8t" ,Ave.; W heat Ridge, CO 80033 Plan Review Office: 303-235-2885 ` Fax: 303-237-8928 Inspection Line: 303«234-8833 Building rmit Application Please complete i ighlighareas on both sides of this form. Incompleto, a0ladlons,may not be processed.' �,. Mailing ddreaa: (if different than property address Address.- Address:Cit City, 9 State, . rc 1te n 1 rE-mail.- 1v Phone - ctor« Contractor: � Contractors City License #-. ly"LLIL t Phone: Contractor E-mailAddress: &me � Su Contractors-. Electrical. Plumbing. Mechanical. W. t. City License # Wk City License W.k City License Other City Licensed Sub: tither City Licensed Sub: City License # City License Complete all information on BOTH sides of this for M� r � • a s• i # � • # "'SIR I#r � # M kP A • • # M � eM MR. # amount of materials to be used, etc.) Amp er 41 ecA6'Y Sq. FULF Stu'e Gallons Amps Squares Other :,,'\., ,".1', City of Wheat Ridge Residential Mechanic PERMIT - 070878 PERMIT NO: JOB ADDRESS: DESCRIPTION: 070878 3690 ALLISON CT Replace existing ISSUED: EXPIRES: 2 1/2 ton AC.& hook up. 08/20/2007 02/16/2008 *.. CONTACTS .. * 303/424-8802 303/422-6606 303/892-0027 Mildred Longman Jim Sanders Jeffrey J. Metzler 01-8083 Sanders & Johnson 01-8121 The Electri-Serve Corp. owner gc sub ** PARCEL INFO ZONE CODE: SUBDIVISION: .. UA 0567 USE: BLOCK/LOTlt: r-3 0/ Permit Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED FEES 108.30 .00 48.69 156.99 PROJECT VALUATION: 2,705.00 ** FEE SUMMARY ** ~~l] Comments: I hereby certify that the setback distances propOsed by this permit application are accurate, and do not violate applicabl ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read arid agree to abide by all conditions printed on t 's application and that I ull sponsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable a Ri r work under this permit. PI s subject to field inspection. 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of t State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, 'a new permit may be acquired for a fee of one-half the amount normally required, 'provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) ye~r, full fees shall be paid for a new permit. 4. No work of any inanner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance 0 a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an appr va 0 ny violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All pI is subject to field inspections. signatur date INSPBCTION RBQOBST LINB: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. aUILUI","," '";:)t'CI..IIV" UIVI;:)IU" - ",.sth"UOO CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Date: Property Owner: Property Address: Contractor License No. : Company: ~ tr~ ~ ~.tf::!~~ Phone: $/z f'- J"J"z- Phone: 1z2 -t~t7~ OWNERlCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I Mtoby certify thallhe selb8d< distances pmposad by this ........ eppIIcellon are eccurele. _ do not vlolale apllllceble otdlna"""s. rutes or regulellons 01 the CIty of Wheel Ridge or ........nls. easemenls or ...!lIIlc:IIons 01 record: 1he1 aft _nls s'-n. and alltig_ ..- are accurele: Ihall have ..ad and agree 10 abide b ai_ions Ilflnled on thls eppIIcellon. and Ihal I assume lull responsiblllly lor with the Wheel Ridge BulIdlng ~ IU.B.C.) and all other app_ Wheel R rd thls pennIl. (OWNERXCONTRACTOR) SIGNED Construction Value: Z. 7 0 S-- Permit Fee: USB Tax: Oescriplion : Total: MdZ~~ " ~ J .ltlIJj'~~lt_lll'l (I ! 11..' r Approval: Zoning : ~'~ I .IJ. 'Xl!~d('~' I 'J-! Approval: fB1!!!Jl'~lJDItlUI'U.;J Approval: Occupancy: Walls: Roof: Stolles: Residential Units : Electncal license No: "I Z-B Company: ~.~ Plumbing License No : Company: MechanICal license No : Company: Expiration Date : Approval: J prllls R6qulttll;:- Expiration Dale: Approval: .3 Pllha Rilqulred ,.I Expiration Date: Approval: :.i f p~na Rlql!!rlRlR,,:l fl) 0111 pen'" WJI, fS,ued in ~ WIth)he pl'0Vt36onS HlIfoI1h In yopur eppIicIIlfon .nd is ,utJIed to....1ews 01' the S1lI1e 01 ColOrado..... to .. Zorq ROljUI.-. _1luiId;nq c_ "''''''''., RIdqe. C_.. ony _ ._bIe OldInonces "'... CIy. (2) thi!l ~,mtI ,ha. eXp"e .. fA) ,he work a"lhon,ed .. not ..........._--4 wtfhfn ..tv ,eo) d.,s "om I...... dale or (8) ... building lIUlhoriZed.. tulpended or abanrtoned lor . Pf'nod 01120 days. (3) tf IN. petm" t!!Jlptr.S. 8 new Delml may be eequill!d for a fee of one-hIli the amount no,",,,..., reQUIred. provtdH no dlltngeS have bRn or wiI be made in the origin" planS 8nd speoficaUons Rnd any suspenstan Of ab..4.......... h.. not exceeded one tt) re-. H dwtge..... made Of" suspens60n or aH.od\,.......d: eueeds one (1) ye.... full fee, sh811 be paid for. nt!W pemIIt. (4) No WOfk of any ~oer shan be dOne that will change the nalUral now of water eauslncJ 8 draInege problem. f5t ConIraclOr shan nobfy the BUilding tnspec10r twenty.1ot,w (24) hours", lIdYance tor "InspeCIIonS ... Shan reeerve WOIten approvat on Inspection card before proceediing with succesStve phlsel of the lob. .., The .....nce"'. perml\.. "'. opproval '" "'owing' """ .pedIlcallons _ no! be.....1Iued 10 be I pelmillor. nor In opprovaI of. any violation of Il10 PfO'IsIDl1S "'... btnIding aJCle... ony _ "dlnonce.low. rule.. fll\lIIIIbI. Chief Building Inspector For Mayor THIS PERMtT VAllO ONLY WHEN SIGNED BY THE CHIEF BUilDING INSPECTOR AND MAYOR CAll: 234-5933 24 HOURS PRIOR TO INSPECTION ,';'" '. /.~. ...., '" ..;(,' k .. ", .... ,~I -1..", i " v B~ilding Permit crirY OF WHEAT RIDGE ; 7500,W"29THA~ue WIWlridge, CO 80033 303-235.2855 Pennlt Number 19407 10/2512005 InspeCt/on Line 303.234-5933 Residential Mechanical PROPltRTY'3690 Allison ct OWNER: Mildred Longman Unit: (303) 424.8802 .B Description Replace 1i.Irnape with 93% Allth~f$y Building Approval AuthorlDd'On Zoning 10/25/2005 Approved By C,FOot . Tuesday, Octob",:25, 2005 Page 1 of 1 City of Wheat Ridge Residential Mechanic PERMIT - 061109 PERMIT NO: JOB ADDRESS: DESCRIPTION: 061109 3690 ALLISON CT replace furnace ISSUED: EXPIRES: 11/16/2006 70K 95% *** CONTACTS * ** 303/422-6606 303/424-8802 Jim Sanders Mildred Lohnham 01-8083 Sanders & Johnson gc owner ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: UA USE: BLOCK/LOT#: UA 0/ Permit Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED PROJECT VALUATION: 2,660.00 FEES 1:::H W~j;:m 156.18 J12 ~ ** FEE SUMMARY ** Comments: Subject to field inspectoin I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application that as e Eul esponsibility for compliance with the Wheat Ridge Building Code (r.B.C) and all other applicabl t 1d rd' an s for work under is permit. Plans subject to field inspection. 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a p mit or the approval of drawings and speCifications shall not be construed to be a permit for, nor an approval of, ~~:olati o~~~~ons of the building codes or any other ordinance, law, rule or regulation. All plan rev' m ec 0 f <..~ons. Signature of Chief Building Off cal date INSPECTION REQUEST LINE: (303)234-5933 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS BUILDING OFFICE: (303) 235-2855 DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. PTlVE ENERGY CODE j;itv of Wheat Ridae PRESCRI OF 90% AFUE BOILF.RS J FURNACES A MINIMUM ENERGY FACTOR GAS WATE;. HEATERS A MINIMUM 0:;: 93 ENERGY FACTOR ELECTRIC WATER HEAT~~~~~~~~EXCEPT HYDRON1C HEAT) SETBACK THERMOSRTA38 CEILINGS . R.19 CRAWLSPACES R-21 WALLS. - DEPARlMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: Date: Property Owner: Property Address: Contractor License No. : Company: ~~ :#696 ~ c:t Phone: JI!.~-JZg~ ~<>'~~ Phone: '/2-2-(,~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : z,b-~ I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinance!. rules or regulations of the City of Wheal Ridge or covenants. easements or restrictions of record: that all measurements shown. and allegotlons made are accurate; that I have read and ogree to abide by, all condlllons printed on this applicalion. and thai I 855umB full re:!ponsiblli for com I BOca with 'he Wheal Ridge Building Code (V. B.C.) and ther 8ppllcable Wh d d nees, work under this pennlt. DATE ~1n{t4 7~~J9r4~ Permit Fee: Use Tax: Total: Description: BUILDING DEPARTMENT USE ONLY ""lllIH!l'!~it)lJlll[ Ill.~. to Approval: Zoning: BJJ!lpilw..C!mmtJlllffl Approval: rJDl.l~..W!;I1JinttQDlIl1DIII$;! Approv"ll . Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechamcal License No : Company: Expiration Date: Approval: --3 Plllns R6qulriill.;- Expiration Dale: Approval: d prlhe RlIqulred ,.1 Expiration Date: Approval: :.J f Pl~ne Rllql!lt.d,~,,;l 1'1 15) '61 Thl' permit WII' ,,,ued In accordance wllh Ihe provision! !iellorth In yopur appl1callon nnd ,,, ~ublp.cIIO the laws orllle Slale of Colorado end 10 the lonino RequtahOf1! and Ouildinq Corle 01 VVh"~1 Rirtqe. Colorado or any olher applicable ordInances ollie City. Thi, pf!rmll ,h3n eliI'll" ., (A) lh~ work aulhollzed III nol commenced WIthin SIXty (60) deys hom 'nul dale or (9) the building authorized IS !lUspended or nbanrtorled ror 8 pPIlOd 01 120 day.. If Ihi, pl'!lmll l!lfP"U. . new permll may be ecqu1red lor a lee or one.tHIIf Ihe amount normlllly tf~qulred. provided no changes have been or will b@ made in Ihe original plans and speCIfications and any sU'penston or abandonment has not elfceeded one (1) ye.r. II changes .re made or If suspen!lIon or abandonment exceed, one '" ye.u. lull fees ,hall be pltid lor. np.w perml!. No wOlk 01 any manner ~hall be done thai will chanqe lhe nalural now of waler cau,lng 8 draInage problem. Contractor !'hall nOltty the BulltJrng Inspector twenty.four (2", hours In advance for alllnspeellons and shall receive written approval on inspection card berore proceedl;ng With successive phases otlhe lob. The issuance of a permit or thl! approval of drawings and speclllcallons Shall nol be construed 10 be 8 permillor. nor an approval of. any violaUon 01 the proviSions 01 the bUilding cocIes or any other ordinance. law. rule or regulation. '" <21 (J) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOH AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Job Address; COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice J~ Po 4LL/SO'v C7 ///Z/..-?,:; #~-r'7fV/c/7~ J"> 7/&//.??7/ L/JO"'>"c ~~c' ({2J ~R #.?c;.c- .,r:..L;)/ S C-'.=,</A/<'...c..p ;:> ri;G'Y ~07ZC::;-;; ~/77~~/~- t2~L..--;;:r- -----'~~_ _ <<.<k'7// ___ r--' ,";:?5" OF c:.w,.. 7 When corrections have been made, call f 303-234-5933. Date: Inspector Building Permit CITY OF WHEAT RIDGE 7500 West 29TH Avenue Wheatridge, CO 80033 303-235-2855 Permit Number 19407 10/25/2005 Inspection Line 3D3-234-5933 Residential Mechanical PROPERTY 3690 Allison ct OWNER: Mildred Longman Unit: (303) 424-8802 Description Replace furnace with 93 % IFEES IFees IUse Tax IPermil Fee ITolal Fees I ICONTRACTORS IName ISanders & Johnson I IDue 1$23.40 1$62.31 1$85.71 I I ILicense # 118083 I IPaid 1$23.40 1$62.31 1$85.71 I I IPhone 1000 422-6606 ~f Wj1eal Ridae PRESCRIPTIVE ENERGY CODE BOILERS I FURNACES A MINIMUM OF ~.O% AFUE GAS WATER HEATERS A MINIMUM OF .60 ENERGY FACTOR ELECTRIC WATER HEATERS A MINIMUM OF.93 ENERGY FACTOR $ETBACK THERMOSTAT REQUIRED (EXCEPT HYDRONIC HEAT) R-21 WALLS. R-38CEIUNGS'. R-19 CRAWLSPACES Units: OCCllpancy: Walls: Roof: Stories: Sq Feet: I henbyc,ertify that theWbllckdistances proposed by this permit application areacl:urate,anddo not violate applicableordiiutnces, 'roles orregulations OrtheCity of Wheat Ridge or co.ve~acasem , or resmctio ofrecordj tbataIJ measurements shown, and allegations madcare accurate; that I have read and agree to abide by . all conditions printed " ,pllcatio aDdth I assume fuUresponsibility for compliance with the Wheat Ridge Building Code (V.D.C.)and all other applicable Wheat Ridge or a c work nnde this enni~ . .. . .... . (OWNER)(CONTRACTOR) This perini!: wasissuediDaccordancc with the provisions set forth in your application and is subject to the lawsoftlie St,ateor'Colorado llIid to the Zoning Regulations and BuildiIi.g Code ofWbeat Ridge, ColoI'lldo or any other appllcable ordinances of the City. This permit shall eXpire If(A) the workautholized Is not commenced within siXty (60) days from issue date or (8) the building authorized issuspended or abandoDed for a period Of120 days. If this permit expires, a newper~t may be acqulredfor a fee of one-half the amount nomally required, provided nO,changes have beenorwill be made in the original plans and specifications and any suspcnsion or abandonment has not exceeded one (1) year. U changes are made or ifsnspension or abandonment ellcecds one (1) ycar, full fees shall be paid fora uew permit. 4 No work ohny manner shall be done that will change the natural flow of water cansing a drainage problem; 5 ContractorshaU uotlfy the Building Inspector twenty"four(2 ours in advance for all inspections and shaUreceive written approval on inspeCtion card before proceeding with snccessive phases of the job. 6 pecificai:ions shall not be construed to be a permit for, nor an approval of, any violation of e ,Iaw,ruleorregulation. Page 1 of 1 """""''''''. "".'>,","..,""c" e.'>" N V Building Permit CITY OF WHEAT RIDGE 7509 West 2tI'H Avenue WheaIrIdge, CO 80033 303-n5-28S5 Permit NlImber 19407 10/25/2005 Inspection LIne 303-234-5933 Residential Mechanical :(.1 PROPERn' 3690 Allison ct OWNER: MIIQred Longman Dese)'lptlon > Replace furnace wi~ 93% Unit: (303) 424~8802 AutHOriZed By, Suildlng Approval Autltorlzed On Zoning 10/25/2005 Approved By c.root Tuesday, Ottober25.2.00S Page 1 ofl UEPARtMENT UF PLANNING ANUDEVELOI'MENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: ! Ci.Ljo 1- Date: Property Owner: /'fILO;2Cp L.",~ NA..J Properly Address: 3;. 9 ~ ~LLIs...,J & Contractor License No. : /80 8 3 Company: 5/JNQOlS t J...JolIIl.s;,"'\ Phone: 3 - c/;;'/-Z:i"6 0 'L Phone: 3. Y~2- -1010.1. OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Conslruction Value: e 11 . Permit Fee: I y:o .c9 Use Tax: I hereby certify that the selback dlslances proposed by this permit appllcallon Rre Becura's. and do not violate applicable ordinances. rules or regulations of the City 0' Wheat Ridge or covenants. easements or reslridlon, of record: thai all measurements shown. and allegallons made are accurate: that I have read and 8C).ree to abide by all condlllons printed on this applicallon. and Ihall assume full responslblllt r corn "anca ith the Wheat fUdge Building Code (U.B.C.) and III other applicable Wheat I eon n . for work under thls~rmlt. / (" _J ~ (OWNER)(CONTRACTOR) SIGNED DATE ~>(. > Description: 1!-f[.ILAL~ fV~"'M..." Tolal: , .I~' 0 3 ~J..~ vv 'M I (<.. 70,"~ 1>1\1 BUILDING DEPARTMENT USE ONLY 41llnllJ!f!~t')W"llll! to Approval: Zoning: IIlIRll1lIliJ.i.I101I11l1J1l1"lf Approval: rJl-1l.IIlr.Wbllintl.Qf1)l11JiIUll:! Approval: Occupancy: Walls: Roof: Stories: Residenli~1 Units: Electncal License No : Company: Plumbing LIcense No : Company: Mechanical License No : Company: Expiration Date: Approval: ..J PlAns Rilqulfed .;- Expiration Dale: Approval: ...J Plaha Required ,.1 Expiration Dale: Approval: ~ r PI~na RlIqI!Jnftl,'1,,::1 '" '2) 13/ ThIS permit W;I' lS!;ued in accord,lnce With the prOVisions sel forth In yapur application nnd i!li !lUbl'eel 10 lhe laws of Ihe Slale 01 Colorado and 10 the Zoning Requlattons and 8vildinq Code 01 V\lhp"lllldqe. Colorado or any olher applicable ordinances 01 I If! CIty, ThiS p"!'tmll ,hall explu! " (A) the work aulhom:ed II not commenced wllhin SUlly (60) dlyt Itom InuI d81l1 or IB) the building authorized II suspended or abandoned 10f a pflHIOd of t 20 days If this permlll!'ll'p"es, a new pe,mlt may be 8cf1ui1ed 'or a fee 01 one-half lhe amount normally u~qulred. provided no Changes havfl been or will be made in the original pll'JnS and speoficalions and any !IIuspen!!lton or abandonment has nall!lJCc@ededane t t) yea'. If changes .re made or If suspenSIon or abandonment eJlC@edsoneHlyear. full fees Shall be paid for II new permIt. No work of any mann!!r 'lhall be done 1hat will change the nalural now 01 water causing 9 drat.u'ge problem. Contractor shan nollfy Ihe BUilding Inspector twenty.lour (24) hours In advance lor alllnspecllons and shall receive wnllen approval on inspection card before proceediing WIth succesSIve phases or Ihe lob. The issuance 01 a permil or 1/1e approval 01 drawings and specilicaltons shall nol be construed 10 be I permit lor. nor an approval of. any violalion of the proviSions of lhe building codes or any olher ordinance. law. rule or regulation. ,., (51 161 Chief Building Inspeclor For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION