Loading...
HomeMy WebLinkAbout4220 Hoyt Court1* � � i City of Wheat Ridge �� Residential Sewer Repair PERMIT - 202100896 PERMIT NO: 202100896 ISSUED: 05/06/2021 JOB ADDRESS: 4220 Hoyt Ct EXPIRES: 05/06/2022 JOB DESCRIPTION: Repair sewer line 10 ft. in front yard - installing a set of clean outs *** CONTACTS *** SUB (303) 856-7476 JACOB WAKEHAM 140058 DIG BOSS LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KI PL ING , 1-70 & CLEARCREEK ARE BLOCK/ LOT# : 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 91875.00 FEES Total Valuation 0.00 Use Tax 207.38 Permit Fee 204.30 ** TOTAL ** 411.68 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Sewer Repair PERMIT - 202100896 202100896 ISSUED: 05/06/2021 4220 Hoyt Ct EXPIRES: 05/06/2022 Repair sewer line 10 ft. in front yard - installing a set of clean outs I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 05/06/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. INSPECTION RECORD Inspection online form: http://www.cl.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: ADDRESS: �IXJOB CODE: Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT:do/ A)73P 0 ADDRESS: bAfl Il JOB CODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial rj 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential rj 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 "*''For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection' 414 Fire Insp. / Fire Protection*** 415 Public Works Final"* 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE `I Inspection Type: `7 3 r Job Address: 1 1L G Permit Number: 20 170 236 Q) ❑ No one available for inspection: Time �: �'% AM/PM Re -Inspection required: Yes (No) *When77ci7l; ave been made, call for re -inspection at 303-234-5933 Date: Inspector: —A—r# DO NOT REMOVE THIS NOTICE *** COMMENTS *** *** CONDITIONS *** 4220 Hoyt Court is in the floodplain. At the house the flood depth is about a foot, so any utilities need to be elevated 2 feet above the ground. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perfortrred-and.that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or . CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of 'e it shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any or dm regulation of this jurisdiction. Approval of work is subject to field inspection. u Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge " Residential Solar PERMIT - 201709360 PERMIT NO: 201709360 ISSUED: 01/25/2018 JOB ADDRESS: 4220 Hoyt CT EXPIRES: 01/25/2019 JOB DESCRIPTION: Install a 7.15 KW roof -mounted grid -tied solar PV system. *** CONTACTS *** OWNER (805)341-2415 HANDLEMAN GEORGIA SUB (888)765-2489 Jared A Miller 110035 SolarCity Corporation *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,724.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** 4220 Hoyt Court is in the floodplain. At the house the flood depth is about a foot, so any utilities need to be elevated 2 feet above the ground. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thisermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be perfortrred-and.that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or . CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of 'e it shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any or dm regulation of this jurisdiction. Approval of work is subject to field inspection. u Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheatidge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 FOR OFFICE USE ONLY Date: N-30/711 Plan/Permit # o 1.=/ b l .3(, P' Plan Review Fee: 150b Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 4220 Hoyt Ct, Wheat Ridge, CO 80033 Property Owner (please print): Georgia Handleman Phone: (805) 341-2415 Property Owner Email: ghandleman@gmail.com Mailing Address: (if different than property address) Address: Same as above City, State, Zip: Arch itect/Engineer: Arch itect/E ng 1 neer E-mail: Contractor: Solar City Contractors City License #: 110035 Contractor E-mail Address: tward@solarcity.com Sub Contractors: Electrical: Plumbing: W.R. City License # W.R. City License # Other City Licensed Sub: City License # Phone: Phone: 253-720-4461 Mechanical: W.R. City License # Other City Licensed Sub: City License # Complete all information on BOTH sides of this form Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT x OTHER (Describe) Solar PV (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Install a 7.15 kW roof -mounted grid -tied solar PV system Sq. FULF 3� O . 2 � 4W I 1111 I Amps 1 Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) _9724 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)W] ""'wily signed by Jeremy Burks Jeremy Burks Jeremy Burks Date 01711.29161514 2 PRINT NAME: SIGNATURE: -0700 DATE: 11/29/2017 DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: 112_r110--__ 1� / Reviewer: (/ l/ PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required Building Division Valuation: $ Kimberly Cook From: Mark Westberg Sent: Tuesday, December 12, 2017 12:43 PM To: Kimberly Cook Cc: Brian Tardif Subject: RE: Weekly Logs Building Folks Just one thing • 20179360 —4220 Hoyt Court is in the floodplain. At the house the flood depth is about a foot, so any utilities will need to be elevated 2' above the ground. Mark A Westberg, PE, CFM Projects Supervisor Office Phone: 303-235-2863 City cit W h Ige- From: Kimberly Cook Sent: Tuesday, December 12, 2017 11:02 AM To: Brian Tardif <btardif@ci.wheatridge.co.us>; Dave Brossman <dbrossman@ci.wheatridge.co.us>; Kenneth Johnstone <kjohnstone@ci.wheatridge.co.us>; Lauren Mikulak <Imikulak@ci.wheatridge.co.us>; Mark Van Nattan <mvannattan@ci.wheatridge.co.us>; Mark Westberg<mwestberg@ci.wheatridge.co.us>; Meredith Reckert <mreckert@ci.wheatridge.co.us>; Russ Higgins <rhiggins@ci.wheatridge.co.us>; Kristine Roed <kroed@ci.wheatridge.co.us>; Scott Brink <sbrink@ci.wheatridge.co.us>; Scott Cutler <scutler@ci.wheatridge.co.us>; Steve Nguyen <snguyen@ci.wheatridge.co.us>;'Kevin.Ferry@arvadafire.com' <Kevin.Ferry@arvadafire.com>; 'nrosenberger@fairmountfire.org' <nrosenberger@fairmountfire.org>; 'steven.parker@arvadafire.com' <steven.parker@arvadafire.com>; Zackary Wallace<zwaIlace@ci.wheatridge.co.us>;'wkeith@westmetrofire.org' <wkeith@westmetrofire.org>; Randy Slusser <rslusser@ci.wheatridge.co.us>; Dina Kemp <dkemp@ci.wheatridge.co.us> Cc: Antoinette Kulick <akulick@ci.wheatridge.co.us> Subject: RE: Weekly Logs Hello, Attached are the weekly logs. If there are any updates, please let me know as soon as possible. Please note, the Plan Review Log is now sorted by color (yellow is in review, white has been reviewed/issued) and then sorted by date so the newest will be on top. Thanks! Kim Cook Permit Technician 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2876 Fax: 303-237-8929 www.ci.wheatridge.co.us Gly of W heat id1gc CA)M%41JN1IY DI VIIM.MtN1 � CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. Pliol 15,10" ll Fit II,P I'• l k I, I ;!(�I'�LI-f.7 'v <_I I\I I:.',c KLI�' 1 12l, \1.a'% CITY OF WHEAT RIDGE PLAN REVIEW COMMENTS FOR SINGLE FAMILY DWELLING ROOF MOUNTED PHOTOVOLTAIC SYSTEM Project Description: Roof Mounted Photovoltaic System for Single Family Home Project Address: 4220 Hoyt Ct. Plan Check No.: 201709360 Permit App. Date: 11/30/2017 Permit Valuation: $9,724 Use: Residential Adjusted Valuation: $22,000 Occupancy: R3/U No. Stories: 2 Const. Type: VB Sprinklers: ❑ Yes ❑ No Architect/Engineer: Miguel Jimenez Phone: Applicant/Contact: T. Ward Phone: (253) 720-4461 Plan Checker: Dan Schultz Phone: (303) 235-2803 Engineer email: dannyschultz@caaprofessionals.com ® 1st Review: 12/1/2017 ® 2nd Review: 1/8/2018 ❑ 3rd Review: Italic comments By Appointment The project plans were reviewed for compliance with the following codes and standards: 2012 International Residential Code (IRC); 2012 International Building Code (IBC); 2014 National Electrical Code (NEC) 2012 International Fire Code (IFC) and the 2012 International Plumbing Code (IPC) • RESPONSE LETTER. To expedite project approval, please provide a separate written response indicating the sheet number, note number & or detail n • umber where each comment was addressed on the plans. • Cloud and delta all revisions and include in the title block of all pages. • Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. • AFTER 2nd PLAN REVIEW: Please call the plan check engineer listed above to schedule a plan review appointment, to expedite project approval. • For clarification of any plan review comment, please call the plan check engineer listed above. Note: Plan checks expire 360 days from date of submittal. General Return all sets and documents plus 2 revised sets and documents. Provide a response letter, cloud all revisions and note the page number the revision can be located. eamnre� _ rrss 1llFatn.rl �n�har2it � „FI;�+� . „+h !, �.-H.�...J .,1,.-+.-„�+;�, .-!, n� + I' N •, IF 605 -11:3, 6” 611- 10- 1100111 _. 111111111 111. . . . . . . . . . . . . . . . . . . ....... . . Architectural & Structural 5. Specify location of roof access point on the roof plan sheet 2 and on the directory placard sheet 7. "Roof access points requiring a ladder shall be located in areas that do not require the placement of ground ladders over openings such as windows or doors and located at strong points of building construction in locations where the access point does not conflict with overhead obstructions such as tree limbs, wires or signs." (IFC 605.11.3.1) (Pending) Roof access point not indicated. R01100mil- 2 CHARLES ABBOTT ASSOCIATES, INC. 390 INTERLOCKEN CRESCENT, 3H11 FLOOR, BROOMFIELD. W 80021 Tolt.FREE: (866)530-4980 E,,,A.41L: W\VW.CAAPR0FESS10NA1.S.00M 6. Specify type, size and spacing of existing roof framing members on the plans per the structural calcs. (Pending) Framing members not shown or noted on the plans. Electrical 7. It appears that the main panel is an end -fed panel. Specify if the main service panel (MSP) is end fed or center fed. (Pending) Based on the panel description in the single line with "multiple main breakers" the panel is likely a split bus panel. The maximum number of main breakers in a split bus panel is six. With the addition of the back feed of the MP2 and the existing load center, the lower bus may still be energized after shutting off all breakers in the main panel. If this is a split bus panel, please clarify in the single line diagram the split bus configuration. You may need to relocate the MP2 but need to know the configuration of the existing panel. Provide a photo of the existing main panel. End fed panels Markings, labels and Wiring Signs 10. Specify the format of all markings, labels and wiring signs including letter and background colors, letter height and capitalization, etc. (noting that labels shall conform to the NEC is insufficient.) All labels shall be in compliance with ANSI Z535.4-2011 section 7 and safety colors of ANSI 535.1 safety colors as follows: a. DANGER: safety white letters on a safety red background b. WARNING: safety white letters on a safety orange background. c. CAUTION: safety black letters on a safety yellow background. d. NOTICE: italicized safety white letters on a safety blue background. e. SAFETY INSTRUCTIONS or similar words: safety white letters on a safety green background. (Pending) Not addressed. MIKETSWE 1110 om Now a a 3 CHARLES ABBOTT ASSOCIATES, INC. 390 IN FERLOCKEN CRESCENT, 31° FLOOR• BROOMFIELD. CO 80021 TOLL FREE: (866) 530-4980 EMAIL: NVNVNV.CAAPROFESSIONALS.COM 13. Since the inverters are not grouped, specify the directory placard shall be placed at both inverter locations. Note this on sheet 7. A permanent, weather resistant, etched, site specific directory placard label shall be installed at each service equipment location (inverter) and at locations of all electric power production sources capable of being interconnected (exception: service equipment grouped together may provide one directory placard.) NEC 705.10. (Pending) not addressed. , M X72TWIM.r_�ss __ 4 CHARLES ABBOTT ASSOCIATES, INC. 390 INTERLOCKEN CRESCENT, 31° FLOOR- BROOMFIELD. CO 80021 TOLL FREY: (866) 530-4980 EMAIL: WAVW.CAAPR0FESSI0NALS.00M __ 4 CHARLES ABBOTT ASSOCIATES, INC. 390 INTERLOCKEN CRESCENT, 31° FLOOR- BROOMFIELD. CO 80021 TOLL FREY: (866) 530-4980 EMAIL: WAVW.CAAPR0FESSI0NALS.00M CAA PR"FFFSSI ON AL B I I I LOINO & $AFF:TY/LN(iI NEER IN O/INFR AST RU('. T LRF. MANA 6F.N7F.NT CITY OF WHEAT RIDGE PLAN REVIEW COMMENTS FOR SINGLE FAMILY DWELLING ROOF MOUNTED PHOTOVOLTAIC SYSTEM Project Description: Roof Mounted Photovoltaic System for Single Family Home Project Address: 4220 Hoyt Ct. Plan Check No.: 201709360 Permit App. Date: 11/30/2017 Permit Valuation: $9,724 Use: Residential Adjusted Valuation: $22,000 Occupancy: R3/U No. Stories: 2 Const. Type: VB Sprinklers: ❑ Yes ❑ No Architect/Engineer: Miguel Jimenez Phone: Applicant/Contact: T. Ward Phone: (253) 720-4461 Plan Checker: Dan Schultz Phone: (303) 235-2803 Engineer email: dannyschultz@caaprofessionals.com ® 15t Review: 12/1/2017 ❑ 2nd Review: ❑ 3(d Review: Italic comments By Appointment The project plans were reviewed for compliance with the following codes and standards: 2012 International Residential Code (IRC); 2012 International Building Code (IBC); 2014 National Electrical Code (NEC) 2012 International Fire Code (IFC) and the 2012 International Plumbing Code (IPC) • RESPONSE LETTER. To expedite project approval, please provide a separate written response indicating the sheet number, note number & or detail n • umber where each comment was addressed on the plans. • Cloud and delta all revisions and include in the title block of all pages. • Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. • AFTER 2"d PLAN REVIEW: Please call the plan check engineer listed above to schedule a plan review appointment, to expedite project approval. • For clarification of any plan review comment, please call the plan check engineer listed above. Note: Plan checks expire 360 days from date of submittal. General 1. Return all sets and documents plus 2 revised sets and documents. Provide a response letter, cloud all revisions and note the page number the revision can be located. Note the following adopted codes on the cover sheet of the plans: 2012 IBC, 2012 IRC, 2012 IFC, 2012 IPC and 2014 NEC. Provide documentation (Certificate of Compliance) from an approved testing agency, that the photovoltaic System has been tested, listed and identified with a Class "A" fire classification in accordance with UL 1703. (The photovoltaic system consists of the racking system and the module as an assembly). Refer to International Solar Energy Industry Agency (CALSEIA) web based data base at http://calseia.org/ul-1703-compliance-database#roof. A-4-11 Print the following jurisdictional notes on the cover sheet: a. "The roof access point requiring a ladder shall not be located over a window, door or located where it conflicts with overhead obstructions such as tree limbs, wires or signs." IFC 605.11.3.1 b. "An OSHA approved ladder shall be provided and secured to the structure at the approved roof access point per note above with a OSHA approved device during all inspections" c. "Applications for a photovoltaic system proposing a partial or complete re -roof of the existing roof shall first obtain a separate building permit for such work from the Building Division by a licensed contractor and shall pass a final inspection prior to installation of the photovoltaic mounting and/or rail system." d. "Direct -Current Photovoltaic Source and Direct -Current Output Circuits on or inside a building shall be contained in a metal raceway. The wiring methods shall comply with the additional installation requirements of NEC 690.31 (G)(1) through (4)" e. "Where a UFER cannot be verified or is not present one supplementary ground electrode shall be installed and embedded a minimum of 8 feet into the ground and fitted with a listed clamping device." f. "Existing roof and plumbing vents shall not be obstructed by array installation. Plumbing vents are required to be re-routed through attic space and terminate a minimum of 6 inches above the roof line." Plumbing vents shall terminate to the open air (2012 IPC, Sec. 904.3) Architectural & Structural 5. Specify location of roof access point on the roof plan sheet 2 and on the directory placard sheet 7. "Roof access points requiring a ladder shall be located in areas that do not require the placement of ground ladders over openings such as windows or doors and located at strong points of building construction in locations where the access point does not conflict with overhead obstructions such as tree limbs, wires or signs." (IFC 605.11.3.1) Specify type, size and spacing of existing roof framing members on the plans per the structural calcs. 2 CHARLi?S A13i3o-rr Asm)('iATUS, INC. 39ulvrn�.uuxr�Cai_virni.3"ru���u 13 0',00'I Tui i i:Ri I :0W,)?;U--t9X0 ENl:A1, : AV VA'VA'.(1,A ARR(Ij I S 0NA ti.( nAI Electrical D t appears that the main panel is an end -fed panel. Specify if the main service panel (MSP) is end fed or center fed. End fed panels d-9- The sum of the ampere ratings of all over current devices supplying the bus shall not exceed the rating of the bus. (120% rule). Need to know the size of the existing main breaker(s). 9. It is not clear where the main breaker is located on the single line diagram. It appears the OCPD for MP1 (Inverter 1) is in.thr not at.the opposite end of the bus. The photovoltaic back -feed over current protection device shall be installed at the opposite end of the bus from the main feeder. NEC 705.12(D)(3)(b) (z) 7egcify s Labels and Wirin Si ns 10. the format of all markings, labels and wiring signs including letter and background colors, letter height and capitalization, etc. (noting that labels shall conform to the NEC is insufficient.) All labels shall be in compliance with ANSI Z535.4-2011 section 7 and safety colors of ANSI 535.1 safety colors as follows: a. DANGER: safety white letters on a safety red background b. WARNING: safety white letters on a safety orange background. c. CAUTION: safety black letters on a safety yellow background. d. NOTICE: italicized safety white letters on a safety blue background. e. SAFETY INSTRUCTIONS or similar words: safety white letters on a safety green background. � te on the label sheet: "All placards shall be weather resistant permanently etched placards. Handwritten signs will not be acceptable" ii-TrProvide a permanent warning label on the main panel that states: "WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES EXCLUDING MAIN SUPPLY OVER CURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR" NEC 705.12 (D)(2)(3)(c) Onverter nce the inverters are not grouped, specify the directory placard shall be placed at both locations. Note this on sheet 7. A permanent, weather resistant, etched, site specific directory placard label shall be installed at each service equipment location (inverter) and at locations of all electric power production sources capable of being interconnected (exception: service equipment grouped together may provide one directory placard.) NEC 705.10. AgjProvide a reflective plaque or reflective directory identifying the rapid shut down system in all caps with white 3/8" high minimum white letters over red background as follows: "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" NEC 690.56 (C) CHARLES ABBOTT ASSOCIATES, INC. 390INTI-RLO( KIN CRI SCFNT.3P' FLOOR' BROOMFULo, CO 80031 Tou FR :(866)530-4980 EMAIL: WN-W.CAAPROF FSS I NAI_S.C(M CITY OF WHEAT RIDGE JURISDICTIONAL NOTES FOR SINGLE FAMILY DWELLING ROOF MOUNTED PHOTOVOLTAIC SYSTEM The project plans were reviewed for compliance with the following codes and standards: 2012 International Residential Code (IRC); 2012 International Building Code (IBC); 2014 National Electrical Code (NEC) 2012 International Fire Code (IFC) and the 2012 International Plumbing Code (IPC) a. "The roof access point requiring a ladder shall not be located over a window, door or located where it conflicts with overhead obstructions such as tree limbs, wires or signs." IFC 605.11.3.1 b. "An OSHA approved ladder shall be provided and secured to the structure at the approved roof access point per note above with a OSHA approved device during all inspections" "Applications for a photovoltaic system proposing a partial or complete re -roof of the existing roof shall first obtain a separate building permit for such work from the Building Division by a licensed contractor and shall pass a final inspection prior to installation of the photovoltaic mounting and/or rail system." d. "Direct -Current Photovoltaic Source and Direct -Current Output Circuits on or inside a building shall be contained in a metal raceway. The wiring methods shall comply with the additional installation requirements of NEC 690.31 (G)(1) through (4)" e. "Where a UFER cannot be verified or is not present one supplementary ground electrode shall be installed and embedded a minimum of B feet into the ground and fitted with a listed clamping device." "Existing roof and plumbing vents shall not be obstructed by array installation. Plumbing vents are required to be re-routed through attic space and terminate a minimum of 6 inches above the roof line." Plumbing vents shall terminate to the open air (2012 IPC, Sec. 904.3) Markings, Labels and Wiring Signs The format of all markings, labels and wiring signs including letter and background colors, letter height and capitalization, etc. shall be in compliance with ANSI 2535.4-2011 section 7 and safety colors of ANSI 535.1 safety colors as follows: a. DANGER: safety white letters on a safety red background b. WARNING: safety white letters on a safety orange background. c. CAUTION: safety black letters on a safety yellow background. d. NOTICE: italicized safety white letters on a safety blue background. e. SAFETY INSTRUCTIONS or similar words: safety white letters on a safety green background. 3. "All placards shall be weather resistant permanently etched placards. Handwritten signs will "'i not be acceptable" W �e3t Ridge O November 22, 2017 RE: CERTIFICATION LETTER Project/Job # 80011055 Project Address: Handleman Residence 4220 Hoyt Ct Wheat Ridge, CO 80033 AHJ Wheat Ridge SC Office Denver Design Criteria: - Applicable Codes = 2012 IEBC/IBC 2012 IRC, ASCE 7-10, and 2012 NDS - Risk Category = II - Wind Speed = 135 mph, Exposure Category C, Partially/Fully Enclosed Method - Ground/Roof Snow Load = 30 psf (Unreduced) - MP1: 2x6 @ 24" OC, Roof DL = 7 psf, Roof LUSL = 30 psf - MP2: 2x4 @ 24" OC, Roof DL = 6.5 psf, Roof LUSL = 30 psf Version #71.0 - TBD Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.23116 < 0.4g and Seismic Design Category (SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval Hussein A. Kazan, P.E. Professional Engineer Hussein Digitally signed by Hussein T: 60 9.642.9015 laza n email: hkazanoatesia.cornlaza n Date: 2017.11.22 18:03:50 -05'00' City of T = 5 L n vtteat Entice 2voi O 134P c Tesla, Inc. 3055 Clearview `,Nay. San Mateo, CA 94402 p 650 638 1028 f 650 638 1029 Version #71.0 - TBD HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware X -X Spacing Hardware - Landscape Modules' Standoff Specifications X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MP1 72" 24" 41" NA Staggered 60.0% MP2 72" 24" 41" NA Staggered 59.8% Portrait Hardware Hardware - Portrait Modules' Standoff Specifications X -X Spacing X -X Cantilever Y -Y Spacing Y -Y Cantilever Configuration Uplift DCR MP1 48" 20" 62" NA Staggered 60.5% MP2 48" 19" 62" NA Staggered 60.3% Structure Mounting Plane Framing Type Spacing Pitch Qualification Results Member Evaluation Results MP1 Stick Frame 24" O.C. 24° Member Analysis OK MP2 Pre -Fab Truss 24" O.C. 20° Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site. The existing gravity and lateral load carrying members were evaluated in accordance with the IEBC and the I BC. T = 5 L n Tesla, Inc. STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MPI Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf. = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, 15=1.0 Member Analysis Results Summary Governing Analysis Max Moment::1__E Location Capacity DCR Result (+) Bending Stress (psi) 1,438.8 T 6.0 ft 1,547.3 93% Pass Member Properties Summary MP1 6/12 Horizontal Member Spans Overhang 1.16 ft Rafter Properties Actual W 1.50" Roof System Properties Span 1 9.55 ft Actual D 5.50" Number of Spans (w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A (in^2) 8.25 Re -Roof No Span 4 Sx (in.,' 3) 7.56 Plywood Sheathing Yes San 5 Ix(in "4 20.80 Board Sheathing None Total Rake Span 11.72 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 1.83 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 9.92 ft Wood Grade #2 Rafter Sloe 24° PV 2 Start Fb(psi) 900 Rafter Spacing 24" 0. C. PV 2 End Fv (psi) 180 Top Lat Bracing Full PV 3 Start E (psi) 1,600,000 Bot Lat Bracing At Supports PV 3 End E -min (psi) 580,000 Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf. = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, 15=1.0 Member Analysis Results Summary Governing Analysis Max Moment::1__E Location Capacity DCR Result (+) Bending Stress (psi) 1,438.8 T 6.0 ft 1,547.3 93% Pass Member Loading Summary Roof Pitch 6/12 Initial Pitch Adjust Non -PV Areas PV Areas Roof Dead Load DL 7.0 psf x 1.09 7.7 psf 7.7 psf PV Dead Load PV -DL 3.0 psf x 1.09 3.3 psf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load LL/SL' Z 30.0 psf xi 1 x 1 30.0 psf 30.0 psf Total Load(Governing LC TL 1 37.7 psf 1 40.9 psf Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf. = 0.7 (Ce) (Ct) (IS) p9 ; Ce=0.9, Ct=1.1, 15=1.0 Member Analysis Results Summary Governing Analysis Max Moment::1__E Location Capacity DCR Result (+) Bending Stress (psi) 1,438.8 T 6.0 ft 1,547.3 93% Pass ZEP HARDWARE DESIGN CALCULATIONS - MP1 Mounting Plane Information Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Framing Type / Direction PV System Type Zep System Type Standoff Attachment Hardware K�j 24° Y -Y Rafters SolarCity SleekMountTM ZS Comp Comp Mount SRV Section 26.8 Spanning Vents V-Ult No Fig. 1609A Exposure Category Wind Design Criteria Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method K�j Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic Factor K�j 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up p„ -29.5 psf Wind Pressure Down down 16.0 psf ALLOWABLE STANDOFF SPACINGS X -Direction Y Direction Max Allowable Standoff Spacing Landscape 72" 41" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -329 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 60.0% X -Direction Y -Direction Max Allowable Standoff Spacing Portrait 48" 62" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -331 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 60.5% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP2 Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf = 0.7 (Ce) (Ct) (IS) pg; Ce 0.9, Ct=1.1, Is= 1.0 Member Analysis Results Summary Member Properties Summary @ Location Capacity DCR Result (-) Bending Stress (psi) -1,270.0 MP2 5/12 Horizontal Member Spans Overhang 1.16 ft Rafter Properties Actual W 1.50" Roof System Properties Span 1 5.62 ft Actual D 3.50" Number of Spans (w/o Overhang) 2 Span 2 6.10 ft Nominal Yes Roofing Material Comp Roof Span 3 Roof Live Load A (in "2) 5.25 Re -Roof No Span 4 Live/Snow Load Sx (in.13) 3.06 PI ood Sheathing Yes San 5 Total Load(Governing LC Ix(in "4 5.36 Board Sheathing None Total Rake Span 13.71 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 0.83 ft Wood Species DF Ceiling Finish 1/2" Gypsum Board PV 1 End 9.08 ft Wood Grade #2 Rafter Sloe 20° PV 2 Start Fb (psi) 900 Rafter Spacing 24" 0. C. PV 2 End Fv (psi) 180 Top Lat Bracing Full PV 3 Start E (psi) 1,600,000 Bot Lat Bracing At Supports PV 3 End E -min (psi) 580,000 Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf = 0.7 (Ce) (Ct) (IS) pg; Ce 0.9, Ct=1.1, Is= 1.0 Member Analysis Results Summary Member Loading Summary @ Location Capacity DCR Result (-) Bending Stress (psi) -1,270.0 Roof Pitch 5/12 Initial Pitch Adjust Non -PV Areas PV Areas Roof Dead Load DL 6.5 psf x 1.06 6.9 psf 6.9 psf PV Dead Load PV -DL 3.0 psf x 1.06 3.2 psf Roof Live Load RLL 20.0 psf x 0.98 19.5 psf Live/Snow Load LL/SL'°Z 30.0 psf X1 I x 1 30.0 psf 30.0 psf Total Load(Governing LC TL 1 1 36.9 psf 1 40.1 psf Notes: 1. ps = Cs`pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-21 2. pf = 0.7 (Ce) (Ct) (IS) pg; Ce 0.9, Ct=1.1, Is= 1.0 Member Analysis Results Summary Governing Analysis Max Moment @ Location Capacity DCR Result (-) Bending Stress (psi) -1,270.0 6.8 ft -1,709.9 74% Pass ZEP HARDWARE DESIGN CALCULATIONS - MP2 Mounting Plane Inforrnation Roofing Material IBC 2012 Comp Roof Table 30.3-1 Roof Slope Framing Type / Direction PV System Type Zep System Type Standoff Attachment Hardware Ke 20° Y -Y Rafters SolarCity SleekMountTm ZS Comp Comp Mount SRV Section 26.8 Spanning Vents V-Ult No Fig. 1609A Exposure Category Wind Design Criteria Design Code IBC 2012 ASCE 7-10 Table 30.3-1 Wind Design Method Ke Partially/Fully Enclosed Method Section 26.8 Ultimate Wind Speed V-Ult 135 mph Fig. 1609A Exposure Category I C Section 26.7 Roof Style qh Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 30.3-1 Topographic Factor Ke 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Trib Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V"2) Equation 30.3-1 3.0 psf 33.7 psf T -actual Wind Pressure Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5A/B Ext. Pressure Coefficient Down GCp (Down) 0.45 Fig. 30.4-2A/B/C-5A/B Design Wind Pressure p p = qh (GCp) Equation 30.4-1 Wind Pressure Up p„ -29.5 psf Wind Pressure Down p down 16.0 psf ALLOWABLE STANDOFF SPACINGS X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 41" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -328 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 59.8% X -Direction Y -Direction Max Allowable Standoff Spacing Portrait 48" 62" Max Allowable Cantilever Portrait 19" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W -PV 3.0 psf Net Wind Uplift at Standoff T -actual -330 lbs Uplift Capacity of Standoff T -allow 548 lbs Standoff Demand/Capacity DCR 60.3% CERTIFICATE OF COMPLIANCE Certificate Number 20150/02 - E346702 Report Reference E346702 - 20140208 Issue Date 2015 -JANUARY -02 Issued to: ZEP SOLAR INC 161 Mitchell Blvd Ste 104 San Rafael, CA 94903-2085 USA This is to certify that Mounting Systems, Mounting Devices, Clamping Devices representative samples of and Ground Lugs for Use with Photovoltaic Modules and Panels Zep System (Steep Slope) with Type 1 modules Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 2703, "Outline of Investigation for Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels." Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information The Zep System (Steep Slope) achieved a system fire classification `A' when tested in combination with UL1703 Listed Type 1, rated PV modules. The system fire test method was in accordance to Standard For Safety For Flat - Plate Photovoltaic Modules and Panels, UL 1703, 3rd Edition, dated May 20, 2014. Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow -Up Service. Look for the UL Certification Mark on the product City of Wheat Ridge �Jldirq �iVison Bruce Mahrenholz, Assistant Chief Engineer, Global Inspection and Field Services L UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC tUL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at-ul.com/contactus Page 1 of 1 A on w O N . ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED —THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD AC ALTERNATING CURRENT POWER—CONDITIONING INVERTER. OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY —AN OSHA APPROVED LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOTE ABOVE WITH DC DIRECT CURRENT SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH A OSHA APPROVED DEVICE DURING ALL INSPENCTIONS. EGC EQUIPMENT GROUNDING CONDUCTOR ART. 110.3. —APPLICATIONS FOR A PHOTOVOLTAIC SYSTEM PROPOSING A PARTIAL OR COMPLETE RE—ROOF OF THE EXISTING ROOF SHALL FIRST OBTAIN A SEPARATE (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING BUILDING PERMIT FOR SUCH WORK FROM THE BUILDING DIVISION BY A LICENSED CONTRACTOR AND SHALL PASS A FINAL ISPECTION PRIOR TO INSTALLATION EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, OF THE PHOTOVOTAIC MOUNTING AND/OR RAIL SYSTEM. FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. —DIRECT—CURRENT PHOTOVOLTAIC SOURCE AND DIRECT—CURRENT OUTPUT CIRCUITS ON OR INSIDE A BUILDING SHALL BE CONTAINED IN A METAL RACEWAY. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE THE WIRING METHODS SHALL COMPLY WITH THE ADDITIONAL INSTALLATION REQUIREMENTS OF NEC 690.31 (G) (1) THROUGH 4)' ( GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY —WHERE A UFER CANNOT BE VERIFIED OR IS NOT PRESENT ONE SUPPLEMENTARY GROUND ELECTRODE SHALL BE INSTALLED AND EMBEDDED A MIMUM OF 8 HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART, 210.5, FEET INTO THE GROUND AND FITTED WITH A LISTED CLAMPING DEVICE. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY Imp CURRENT AT MAX POWER WITH ART. 250.97, 250.92(B). —EXISTING ROOF AND PLUMBING VENTS SHALL NOT BE OBSTRUCTED BY ARRAY INSTALLATION. PLUMBING VENTS ARE REQUIRED TO BE RE—ROUTED Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING THROUGH ATTIC SPACE AND TERMINATE A MINIMUM OF 6 INCHES ABOVE THE ROOT -LINE. kVA KILOVOLT AMPERE OR ARE RUN IN METALLIC RACEWAYS OR kW LBW KILOWATT LOAD BEARING WALL ENCLOSURES TO THE FIRST ACCESSIBLE DC ��� City of Q; wh�tl_e DISCONNECTING MEANS PER ART. 690.31(E).% CoMMUNiIYDivEtCN'MEHtT MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY APPROVED NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE Reviewed for Code Compliance OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE `( O SCH SCHEDULE I BONDED WITH EQUIPMENT GROUND CONDUCTORS. PlansEximiner Dace S STAINLESS STEEL Val'ditypfoom,;t.,r�ax,bK�afaa�,,�appavaiarpl STC STANDARD TESTING CONDITIONS and computotrons shot! not br, a pemut for, or an opprowl ot aq riohtion ya TYP TYPICAL o -of the provisions of the &MdOV code a of ary Cd y ordM000rs rwksr at UPS UNINTERRUPTIBLE POWER SUPPLY wesminvto9weouttwftytaviowecfc~ the Provdiom pfth<,,,w, code or other ordMonces of the City shoes not he void. V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W 3R WATT NEMA 3R, RAINTIGHT , —" Sheet 1 COVER SHEET - - Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS GENERAL NOTES • Sheet 4 STRUCTURAL VIEWS Sheet 5 UPLIFT CALCULATIONS ._ � � `:� LICENSE :I Sheet 6 THREE LINE DIAGRAM 1. ALL WORK SHALL COMPLY WITH THE 2012 IBC, • _ Cutsheets Attached TYPE EC # 8041 2012 IRC AND 2012 IFC. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE. — �+ MODULE GROUNDING METHOD: ZEP SOLAR REV BY DATE COMMENTS AHJ: Wheat Ridge ,t REV A WC 11/22/17 Redesign for ease of install UTILITY: Xcel Energy (CO) - CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-80011055 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OFNYONEDISCLOSED�WHOLEAOINC., NOR GEORGIA HANDLEMAN 7.15 KW PV ARRAY Miguel Angel Jimenez T Sy L MOUNTING SYSTEM: BE ZS Comp V4 wFlashing—Insert 4220 HOYT CT PART TO OTHERS OUTSIDE THE RECIPIENT'SSHALL WHEAT RIDGE, CO 80033 d t MODULES: v ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) SolarCity Standard #SC325 SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: Buildin DIVISOn 9 INVERTER: PERMISSION OF TESLA INC. Delta Solivia 3.8 TL COVER SHEET 1 C 11/22/2017 A on w O N 41 N N 4 (E) DRIVEWAY h C7 Front Of House 3' FSBf?SA LSP El C� R- I � �l RSD ®RSD n/s �I H. SV AC ®I 0CM L � Inv i 7�„CC`D A b l Dg d De Vera e a rd o SAbrCity, dc—local, IXJ: dc=local, dc=SolarCiry, T E o ou=Sola,City Users, ou=Hawthorne, De Vera m aXardo De Vera, �rgaC V O�yt Date: 2o�°,�.;ooa,ro3 �W' STAMPED AND SIGNED FOR STRUCTURAL ONLY PITCH: 24 ARRAY PITCH: 24 MP1 AZIMUTH: 179 ARRAY AZIMUTH: 179 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 20 ARRAY PITCH: 20 MP2 AZIMUTH: 89 ARRAY AZIMUTH: 89 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 20 ARRAY PITCH: 20 MP3 AZIMUTH: 269 ARRAY AZIMUTH: 269 MATERIAL: Comp Shingle STORY: 1 Story @1[@i I LEGEND (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER RAPID SHUTDOWN STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED SITE PLAN N w E S CONTAINED L A THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S61 ORGANIZATION, EXCEPT IN CONNECTION WITH TTHE U,EAOF THE ESLA SAECAIAND OUT RE PECTI VE EN PERMISSION OF TESLA INC. loe NUMBER: J B-80011055 00 PREMISE OWNER: DESCRIPTION: GEORGIA HANDLEMAN 7.15 KW PV ARRAY 4220 HOYT CT WHEAT RIDGE, CO 80033 PAGE NAME: SITE PLAN DESIGN: Miguel Angel Jimenez 9 9 T E o MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert MODULES. SolarCity Standard #SC325 �rgaC V O�yt SHEET! REV: DATE:IPM 2 0 11/22/2017 I(v22)R Delta # Solivla 3.8 TL (N) P� Cc\, V I i ill.NL r'V J1VC V1CVV J NTS PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK ZEP FLASHING INSERT (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW (2-1/2" EMBED, MIN) (E) RAFTER CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. STANDOFF S1, �� Scale: 1 1/2" = 1' JOB NUMBER: JB -80011055 00 MOUNTING SYSTEM: ZS Comp V4 w Flashina—Insert (22) SolorCity Standard #SC325 INVERTER: Delta # Solivio 3.8 TL INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. 'REMISE OWNER: GEORGIA HANDLEMAN 4220 HOYT CT WHEAT RIDGE, CO 80033 LIC 613!1�p0 E. p)"�. G,' yy Abelardo De Abelarc oVera DN: DN: dc=local, dc=SolarCity, ou=Solality Users, ou=Hawthorne, cn=Abelardo De De Vera Vera, email=adevera@solarcity.com Date: 2017.12.10 08:12:02 -08'00' DESCRIPTION: 7.15 KW PV ARRAY PAGE NAME: STRUCTURAL VIEWS DESIGN: Miguel Angel Jimenez SHEET: REV: DATE: 3 a 11/22/2017 T E 51. CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. JOB NUMBER: JB -80011055 MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert MODULES: (22) SolarCity Standard #SC325 INVERTER: Delta # Solivia 3.8 TL 00 PREMISE OWNER: GEORGIA HANDLEMAN 4220 HOYT CT WHEAT RIDGE, CO 80033 SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. 7.15 KW PV ARRAY PAGE NAME: UPLIFT CALCULATIONS DESIGN: Miguel Angel Jimenez SHEET: REV. DATE: 5 a 11/22/2017 T E(S , GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number: NoMatch Inv 1: DC Ungrounded INV 1 —(1)Delta # Solivia 3.8 TL LABEL: A SolorCity Standard #SC325 TYPE EC # 8041 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 47390148 Inv 2: DC Ungrounded Inverter;380ow, 24OV, 97.57, Zigbee, PLC PV Module; 325W, 306.5 PTC, 40MM, Blk Frm, Wht Bocksheet, MC4, 600v ZEP, INV 2 Overhead Service Entrance –(1)Delta # Solivia 3.8 TL LABEL: B Inverter;380OW, 24OV, 97.57, Zigbee, PLC Voc: 69.6 Vpmox: 57.6 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL Multiple Main Breakers (6 or fewer) Inverter 1 (E) WIRING MILBANK CUTLER—HAMMER Meter Socket Disconnect 7 Delta Solivio 3.8 TL (E) LOADS C �• D a F,-, TV 1 Multi—Socket Connector 3 B 1 • ~ L2 A DC= 20A/2P � r – – – – GND – – – – – – "N – — – – – – – – — – – – – – – – – – – – N _ EGC; GEC Dc- – – – � 4 Dc- Dc M P 1; 2x5 B N DC- GND EGC---- DC- EGC I I __ ------- ----------- -- – –– – - SIEMENS VEG/GI Inverter 2 E�C GEC , (E) 125A Load Center MILBANK CUTLER—HAMMER c� — — — , • 9 Meter Socket Disconnect 8 Delta Z ' E Solivia 3.8 11 (E)125A/2P I (N)20A/2P C D Multi—Socket I 0 e � Ll zaov Connector 5 FB]2 I TO 120/240V N SINGLE PHASE UTILITY SERVICE I �— 1 -- f N _ _ _ GNG EGC; GND -- — — —,E DCS ---TN A 6 DG Dc DCS MP 2: 2x6 w o-------------- Dc- Dc- I I EGC--------------- EGC i „ND __ – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – \ ' L L• J \/ I I I I I AC, STANDALONE PARALLEL, NON—EXPORT 16 E)10OA/2 TO (E) LOADS <,\ Voc* = MAX VOC AT MLTEMP POI (1 )SIEMENS # 0220 PV BACKFEED BREAKER C Breaker; 20A/2P, 2 Spaces (2)MILBANK # U4801–XL-5T9 9 n C Meter Socket; 200A, #6-350, Rin less „ B (4)Delto # Solivia p A Smor RSS Rapid Shutdown, 60OV, 20A, NEMA 4X, MC4 (2)MULTI–CONTACT p PV–AZB4 D� Branch Socket C4 U–Joint Connector, Female Female Male – (6) MILBANK M K4977–INT Load–Side Tap Connector; IOOA, #12 – 1/0 AWG –(2)MULTI–CONTACT / PV–AZS4 Branch Plug; MC4 U–Joint Connector, Male Male Female (2)CUTLER–HAMMER # DG321URB E (1 )SIEMENS 0220 PV BACKFEED BREAKER Breaker, 20A/2P, 2 Spaces Disconnect; 30A, 24OVac, Non–Fusible, NEMA 3R – (2)CUTLER–HAMMER g DG10ONB Ground/Neutral Kit; 60-100A, General Duty (DG) (1)Existing Wires (1 )AWG #10, THWN-2, Black (1 )AWG #10, THWN-2, Red ( 5) (4)AWG 110, PV Wire, 600V, Black (1) ANG #10, THHN/THWN-2, Green Voc* = 396.82VDC Isc = 12.06 ADC (4)AWG #10, PV Wire, 60OV, Black EGC Vmp = 288 VDC Imp= 11.3 ADC O (1 )AWG #10 THWN 2, Green EGC Voc* = 396.82VDC Isc = 6.03 ADC Vmp = 288 VDC Imp= 5.65 ADC Vmp =240 VAC Imp=N/A AAC 0 f� �'' T (1 )AWG #10, THWN-2, White – (1) AWG THWN-2, Green #8 NEUTRAL Vmp =240 VAC Imp=15.8 AAC EGC GEC – (1) Conduit Kit; 3 4 EMT / / ' �� // (1)Conduit Kit; 3/4" EMT (i) AWG #10, THWN-2, Black _ – Voc* 396.82 VDC Isc – 12.06 ADC L-1 (4) AWG PV Wire, 600V, Black Voc = 476.18 VDC Isc = 6.03 ADC 7 ( I ) AWG #10, THWN-2, Block(1)AWG #10, THWN-2, Red � #10, Vmp = 288 VDC Imp= 11.3 ADC O (1) AWG #10, THWN-2, Green EGC Vmp = 345.6 VDC Imp= 5.65 ADC ® lar (1 ) AWG #10, THWN-2, Red (1) AWG #10, THHN/THWN-2, Green EGC – I ) Conduit Kit; 3/4" EMT r' (1 )AWG #10, THWN-2, White –(I ) AWG #8, THWN-2, Green NEUTRAL Vmp =240 VAC Imp=15.8 AAC EGC/GEC –(l)Conduit Kit; 3/4' EMT �� (4)AWG 110, PV Wire, 600V. Black (I) AWG 110, THHN/THYN-2, Green Voc* = 476.18 VDC Isc = 12.06 ADC EGC Vmp = 345.6 VDC Imp= 11.3 ADC (1) Conduit Kit; 3/4" EMT (1) AWG #10, THWN-2, Black (1 )AWG #10, THWN-2, Red Voc* = 476.18 VDC Isc = 12.06 ADC Vmp = 345.6 VDC Imp= 11.3 ADC 1 – 1 CONFIDENTIAL – THE INFORMATION HEREIN JQQ 1 OB NUMBER J B-0001 I O55 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR GEORGIA HANDLEMAN 7.15 KW PV ARRAY Miguel Angel Jimenez T - MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 42ZO HOYT CT gS 7 PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WHEAT RIDGE, CO 80033 MODULES: THE SALE AND USE OF THE RESPECTIVE (22) SolarCity Standard #SC325 SHEET: REV: DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME INVERTER: PERMISSION OF TESLA INC. Delta # Solivia 3.8 TL THREE LINE DIAGRAM 6 C1 11/22/2017 'Soq w , ,14 1111 kilos I , I Label Location: (C)(CB)(JB) Per Code: NEC 690.31.G.3 A WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION A WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Label Location (DC)(INV) Per Code: NEC 690.13.13 Label Location: (DC) (INV) Per Code: NEC 690.53 AWARNING Per Code: THIS EQUIPMENT FED BY 690.64 MULTIPLE SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. Label Location: �� r % r,% ,r; (INV) �.n,� _ A-0 Per Code: ,J 7� "a CEC 690.56(C) Label Location: (AC) (POI) Per Code: NEC 690.54 Label Location: (AC)(POI) Per Code: NEC 690.17.E Label Location: (POI) Per Code: NEC 705.12.D.2 Label Set (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center �`'� (M): Utility Meter c; (POI): Point of Interconnectio GIi y.Df _ hear ,� Label Location: A WARNING (DC) (INV) Label Location: Per Code: (AC)(POI) ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS NEC 690.35(F) Per Code: PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN NEC 690.13.6 UNGROUNDEDAND INVERTER IS MAY BE ENERGIZED UNGROUNDED Label Location: (AC) (POI) Per Code: NEC 690.54 Label Location: (AC)(POI) Per Code: NEC 690.17.E Label Location: (POI) Per Code: NEC 705.12.D.2 Label Set (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center �`'� (M): Utility Meter c; (POI): Point of Interconnectio GIi y.Df _ hear ,� Rapid for Delta x i Model RSS-600 4-2 Connection Diagram: r f- 3.ON7,6 TL Inverters Delta's Rapid Shutdown Devices provide an automatic disconnect of 60OVDC residential or small commericial PV array system, fully compliant with the Rapid Shutdown requirements of NEC 2014 article 690.12. It is compatible with Delta's single-phase residential inverters. KEY FEATURES NEMA 4X Protection • Compact and Lightweight • Rack Mount Installation • Fast Connect with PV Connectors • Compliant with NEC 2014 article 690.12 • PLC Communication (Model RSS-600 1-1 only) ,&P{rG., C CH US Standard Compliance DELTA RAPID SHUTDOWN BOX ON ROOF WITHIN 10' OF PV 11—:100011 RAFt3 LrUi[SOIYf1 - - -- DC PV DC PV - AC 5V SIGNAL 600V DC 1 20A N/A 1 20A 25A 10 AW G N/A PLC Signal N/A N/A ttF� J AC AC One conduit BREAKER GRID for all wiring I 600V DC 4 10A 15A 2 20A 25A 12-6 AWG 3/4" (two holes) 5V Signal Wire 600V 24-14 AWG 7.87 x 5.91 x 2.09 ( 200 x 150 x 53) 12.44 x 10.04 x 2-16 (316 x 255 x 55) 2S61bs (1.3kg) 6.6lbs (3.Okg) I PV Connector or Amphenol H4 PV Connector MC -4 PV Connector orAmphenol H4 PV Connector MC -4 PV Connector or Amphenol H4 PV Connector Screw Terminal Blocks -40 - 158-F (40 - 70°C) 40 - 158-F (40 - 70°C) -40 - 185-F (40 - 85°C) 40 - 185-F (-40 - 85°C) 0-100% 0-100% 2000m above sea level 2000m above sea level 10 Years 10 Years NEMA 4X UL 1741, CSA 22.2 107-1 NEC 2014 Article 690.12 Delta Products Corporation, Inc. 46101 Fremont Blvd. Fremont, CA 94538 Sales Email. Inverter.Sales@delta-corp.com Support Email: Inverter. Support@delta-corp.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Fnday from 7am to 5pm PST (apart from Holidays) www.delta-americas.com/solarinverters NEMA4X UL 1741, CSA 22.2 107-1 NEC 2014 Article 690.12 41 SolarCity i Solar Inverters Transformerless (TL): 3.8 kW, 5.2 kW, 6.6 kW, 7.6 kW Wide Operating Voltage Range: 85 - 550V Wide Operating Temperature Range: -13 - 158`F (-25 - 70'C) High CEC Efficiency: 97.5% Integrated AFCI (Arc Fault Circuit Interruption) NEMA 4X plus Salt Mist Corrosion Protection Natural Convection Cooling Dual MPPT (5.2kW / 6.6kW / 7.6kW) Compact and Lightweight UL 1741 / IEEE 1547 / IEEE 1547.1 / CEC r Listed /UL 169913Type 1) / NEC 690.11 C ca us sdarcity 0 Delta Solar Inverters Datasheet for SolarCity INPUT (DC) Max. System Voltage _ 600 V Nominal Voltage e,� 380 V Operating Voltage Range 85 - 550 V Full Power MPPT Range 200 - 500 V Max. Usable Current 18.0 A 20.0 A 20.0 A per MPP tracker Max Short Circuit Current @ STC 25.0 A per MPP tracker Max. Aliowabie Imbalance Power -� - 4200 W 5000 W 5600 W Allowed DC Loading Ratio . 1.5 DC Disconnect Internal MPP Tracker 1 2 Total Input Strings Available 2 4 OUTPUT (AC) Nominal Power 3000 W 3800 W 5200 W 6600 W 7600 W . Continuous Power WIN 3000 W @ 208 V I 3300 W @ 208 V) 5200 W @ 208 V / 6600 W @ 208 V / 6600 W @ 208 V ! 3 F 3000 W @ 240 V 3800 W @ 240 V 5200 W @ 240 V 6600 W @ 240 V 7600 W @ 240 V 37oHage Range 183 - 228 V @ 208 V i 2 i 1 - 264 V @ 240 V inal Current iiiem1ANIIIIII&IIIIII 14.4A@208V1 15.8A@208V1 240A@208V1 31.7A@208V/ 31.7 A@208V/ 12.5A@240V 15.8A@240V 21.6A@240V 27.5A@240V 31.7A@240V #Ominai Frequency 60 Hz floquency Range 59.3 - 60.5 Hz trustable Frequency Rarge 57.0 - 63.0 Hz kht Consumption < 1.5 W total Harmonic Distortion @ Nominal Power <3% ,ower Factor @ Nominal Power -099 Rustable Power Factor Range 0.851 - 0.85c Acournc Noise Emission - 150 ab(A) @ Im GENERAL SPECIFICATION Max. Efficiency _ = 98% CEC, Efficiency 97.5% @ 208V / 97.5% @ 240V Operating Tamperaiure Range - -13 - 158`F (-25-70'C) I d=rating above 122'F (50'C) Storage Temperature Range - -40 - 185-F (40 - 85"C) Humidity 0-100% Max. Operating Attitude ,1 2000m above sea level MECHANICAL DESIGN Size L x W x D inches (L x W x D mm)-•. 19.5 x 15.8 x 8.5 in (495 x 401 x 216 mm) 26.8 x 15.8 x 8.5 in (680 x 401 x 216 mm) Weight 43.0 lbs (19.5 kg) 65 0 lbs (29.5 kg) Coolinc Natural Convection AC Connectors i� Spring terminals in connection box Compatible Wiring Guage in AC -� AWG 12 - AWG 6 Copper ( According to NEC 310,15) DC Connectors 2 pairs of spring terminals in connection box 4 pairs of spring terminals in connection box Compatible Wring Guage in DC AWG 12 - AWG 6 Copper (According to NEC 690.8 ) Communication Interface ZigBee Display 3 LEDs, 4-1-ine LCD Enclosure Material Diecast Aluminum STANDARDS ! DIRECTIVES Enclosure Protection Rating NEMA 4X, IEC 60068-2-11 Salt mist Safety UL 1741 Second Edition, CSA C22.2 No.107.1-01 SW Approva' UL 1998 Grountl-Fauif Protection NEC 690 35, UL 1741 CRD Axiti-Islanding Protection IEEE 1547, IEEE 1547.1 EMC FCC part 15 Class B .AFCI UL 16998 (Type 1), NEC 690.11 PV Rapid Shutdown ILL 1741 CRD PVRSS, NEC 690.12 (with SMART RSS) Integrated Meter ANSI C12.1 (meet 1% Accuracy) Regulation at Grid Support California Rule 21, HECO Compliant. JEEE1547 WARRANTY Standard Warranty 10 years Delta Products Corporation, Inc. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: mverter.sales@dell- com Support Email: inverter.support@deltavv✓.com Sales Hotline: +1-877-440-5851 or -1-626-369-8021 Support Hotline. +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Friday from 7 am to 5 pm PST (apart from Holidays) 'i"SOldrCity I ®pSolar Next -Level PV Mounting Technology '" SOldf�lty i ®pSolar Next -Level PV Mounting Technology ZS pomp for composition shingle roofs Components Mounting Block Array Skirt Part No. 850-1633 Part No. 850-1608 or 500-0113 Listed to UL 2703 Listed to UL 2703 Interlock Part No. 850-1388 or 850-1613 Listed to UL 2703 40 Flashing insert Grip Ground Zep V2 Part No. 850-1628 Part No. 850-1606 or 850-1421 Part No. 850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 �� ooMPare`� Description PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules °OMPpj� Auto bonding UL -listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2' Captured Washer Lag End Cap LISTED Part No. 850-1631-001 Part No, Specifications 850-1631-002 (L) 850-1586 or 850-1460 850-1631-003 (R) 850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 lost per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No. 850-1397 zepsolar_com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar s sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty The customer is solely responsible for verifying the suitability of ZepSolars products for each use. Speafications are subject to change without notice. Patents and Apps. zspats.com. Document # 800-1839-001 Rev D Date last exported: April 29, 2016 11:22 AM W* DC Wire Clip Part No. 850-1509 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services Zep Solar s sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solars products constitutes the sole speoficahons referred to in the product warranty The customer is solely responsible for verifying the suitability of ZepSolars products for each use. Specifications are subject to change without notice. Patents and Apps zspats.com. Document If 800-1839-001 Rev D Date last exported: April 29. 2016 11:22 AM 5C325 More power, C SolarCity ELECTRICAL AND MECHANICAL CHARACTERISTICS With a sunlight to electricity More power per panel Max. power (Pmax) [W] Our 325W panel generates 20% more power than a standard conversion efficiency of over 19.4% 270W panel. the panel ranks amongst the More energy every year highest in the industry. That means More yearly energy (kWh) compared to other panels as they perform better in the heat. our panels can harvest more Outstanding durability energy from the sun, which means With more than 20 additional tests performed beyond what is currently mandated, these panels far exceed industry standards. it takes fewer of our panels to More layers, more power power your home. Plus, they Manufactured by Panasonic for SolarCity, the panel uses Solar Panel efficiency [%] Heterojunction cell technology, which adds a layer of thin film silicon generate more power output on top of high efficiency cyrstalline silicon. during the hottest times of the day, Leading warranty even In warmer Climates' Our panels rank among the best in warranty coverage, with workmanship that extends to 15 years. solarcity.com ROHS a`"""� IEC61215 ❑ 9®� IEC61]70-1 C C .....,... ,r IE061i]0.2 I al, ELECTRICAL DATA 247.5 Max. power (Pmax) [W] 325 Max. power voltage (Vmp) [V] 57.6 Max. power current (Imp) [A] 5.65 Open circuit voltage <Voc) [V] 69.6 Short circuit current (Isc) [A] 6.03 Max. over current rating [A] 15 Power tolerance [%]' +S/ -O Max. system voltage [V] 600 Solar Panel efficiency [%] 19.4 Note: Standard Test Conditions: Air mass 1.5: Irradiance = 100oW/m2. cell temp. 25-C m 'Maximum power at dekvery Por limited warranty conditions, please check — meted warranty documenr MC4 TEMPERATURE CHARACTERISTICS manual carefully Temperature (NOCT) [°C] 44.0 Temp. coefficient of Pmax [%/°C1 -0.258 Temp. coefficient of Voc [%/°C ] -0.235 Temp. coefficient of Isc [%/°C] _ 0.055 AT NOCT (NORMAL OPERATING CONDITIONS) Max. power (Pmax) [W] 247.5 Max. power voltage (Vmp) [V] 54.2 Max. Dower current (Imp) [A] 4.56 Open circuit voltage (Voc) [V] 66.1 Short circuit current (Isc) [A] 4.87 Note: Normal Operating Cell Temp.: Air ma551 5, Irradiance = 800,W/m2 Air temperature 20°C: wind speed 1 m/s AT LOW IRRADIANCE (20%) Max. power (Pmax) [W] 62.0 Max. power voltage (Vmp) [V] - 55.7 Max. power current (Imp) (Al 1.11 Open circuit voltage (Voc) [V] 65.1 Short circuit current (Isc) [A] 1.21 Note: Low irradiance Air mass 1.5. Irrad,ance = 200W/m2: cell temp = 25`C - LIMITED Power output: 10 years (90%of Pen in) WARRANTY 25 years (80% of Pmin) Workmanship. 15 years MATERIALS Cell material: 5 inch photovoltaic cells Glass material: AR coated tempered glass Frame materials: Black anodized aluminium Connectors type: MC4 CAUTION! Please read the installation manual carefully before using the products. MECHANICAL DATA Weight: 42.99lbs Dimensions: 62.611/41.511/1.5711 Connector: MC4 Frame Color: Black Snow load: 5400 Pa Wind load: 2400 Pa / Fire Type: Type 2 I/ E E i e cis) I i Section A -A' t.3B(35) T Section B -B'400 601100 DEPENDENCE ON IRRADIANCE 700 6.00 600w/m= 500 i zoo zoow/m= D ,O 20 30 40 50 60 7 0 BC �Gitage (v, 11 f ;^.e panels a�? mCILdeC. , a PV s seem ,old by SolarCity n 'esla. So-arC�;y anc -?'la ma..e no wa��ant c+s SolarCity s OarClty.COm r?Idled i0 :tie pa'?Is. `NnKh are iOld a5'Is. Sola"City will '-I t' any wd!'a T,y Cla urs On Oc^nalf Ji any pUYC nd:i t' I I I ^ I Q c'' � I I s ce> it I I 3s t.se> 3e 1 I �ytm'+l Gryw.y�3. I e cis) I i Section A -A' t.3B(35) T Section B -B'400 601100 DEPENDENCE ON IRRADIANCE 700 6.00 600w/m= 500 i zoo zoow/m= D ,O 20 30 40 50 60 7 0 BC �Gitage (v, 11 f ;^.e panels a�? mCILdeC. , a PV s seem ,old by SolarCity n 'esla. So-arC�;y anc -?'la ma..e no wa��ant c+s SolarCity s OarClty.COm r?Idled i0 :tie pa'?Is. `NnKh are iOld a5'Is. Sola"City will '-I t' any wd!'a T,y Cla urs On Oc^nalf Ji any pUYC nd:i t' i CITY OF WHEAT RIDGE _1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: M l P Job Address: (--C 't, () 1-1 o -1 1 Permit Number: C 1 6 �- L-) ❑ No one available for inspection: Time -) �401PM Re -Inspection required: Yes No When corrections have been made, call for rection at 3 3=234-59 3 Date: Inspector: DO NOT REMOVE THIS N ICE 41 CITY OF WHEAT RIDGE " Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ri 0 r - Job Address: U -)-a b 4 bt Permit Number: "� `p 1 D 1 9 .P r 17 2 a v .f `o S -T -,a ? V S : CD R!�•r �t - � C ❑ No one available for inspection: Timek U � AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 rr Date: C�' a Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge `y Residential Roofing PERMIT - 201702089 PERMIT NO: 201702089 ISSUED: 06/19/2017 JOB ADDRESS: 4220 Hoyt CT EXPIRES: 06/19/2018 JOB DESCRIPTION: Reroof asphalt shingles using certainteed Landmark shingles 19 sq *** CONTACTS *** OWNER (303)232-1423 WERNER DANIEL P GC (303)995-6433 Bruce Wank 170130 Mountain Roofing LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2002 / KIPLING, I-70 & CLEARCREEK ARE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,000.00 FEES Total Valuation 0.00 Use Tax 147.00 Permit Fee 156.75 ** TOTAL ** 303.75 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A/2-inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€lms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. J City of Wheat Ridge Residential Roofing PERMIT - 201702089 PERMIT NO: 201702089 ISSUED: 06/19/2017 JOB ADDRESS: 4220 Hoyt CT EXPIRES: 06/19/2018 JOB DESCRIPTION: Reroof asphalt shingles using certainteed Landmark shingles 19 sq 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all a yppjicable.mgr!icipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property an am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am leg ally a ttliorized to include all entities named within this document as parties to the work to be performed and that a1f work to be pertor ' is disclosed in this document and/or its' accompanying proved plans and specifications. ,. Signature of OWNER or CON Circle one) Date I . This permit was issued 1pimed on the infor nation provided in the permit application and accompanying plans and specifications and is subject to the compli ce with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall ex fire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to thio date of expiration,.Ain extension of no more than 180 days made be granted at the discretion of the Chief Building Official and. may b&,subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, anew permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. j. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS NUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. ESTIMATE OF WORK A{° DIOR CONTRACT Date 6/6/17 ,lob Name Customer_ Daniel Werner Address 4220 Hoyt Ct City Wheat Ridge State CO Zlp 80033 Phone 303-232-1423 Cell moumin 24 Lindenwood Lane I Littleton, CO 80127 p: 303.995.64331 a: 9.3380 0 Bruce®mountainrooting.net BBB.Roon� www.mountainroofing.net eu NE S A Colorado Company Insurance Co. American Ntional Insurance Phone 608-509-3926 Claim 105 -H -3H7393 Fax Email_ d.werner74@gmail.com i Adjuster Farrand Keith Cell.__ JDB DESCRiIPiION: ElManufacturer Certainteed ❑Type of Roof Landmark ❑Color of Shingle Weatherwood ❑Tear Off Dimensional ❑Ridge Type Shadow Ridge ❑Valley Type closed ❑Metal Edge / Color 2"x4" & 2"x 2" drip edge / brown ❑vents / Color slant back vents brown ❑Install Six Nails Per Shingle Yes ❑Pipe Flashings Muli-Size 1.5 2 3" / exhaust cap only El Ice and Water Shield per code ❑Felt Underlayment synthetic []Manufacturers Limited Liability Warranty Per manufacturer ❑Mountain Roofing Limited Liability Warranty 3 years ❑Clean Up and Haul Off Roofing Debris Yes El Run Magnetic Nail Rake Through Yard Yes []Protect Landscape yes ❑Includes Building Permit, taxes, Dump Fee supplement Insurance ❑Install New Gutters 5" gutters no downspouts Royal Brown ED Lien Waiver Provided Upon Final Payment yes _ NOTES'/ SPECIAL INSTRUCTIQtis- DEDUCTIBLE DUE AT TIME OF MATERIAL DELIVERY. NET CLAIM CHECK DUE UPON A COMPLETION OF ROOF AND GUTTERS. Mountain roofing will supplement insurance company directly for any items such permit, code requirements that are not included in the initial adjustment but are deemed part of the approved repairs. Additional funds become part of Mountain Roofing invoice though not included on this contract. Contractor will do only the following items below associated with claim #05 -H -3H7393 report dated 5/18/17 Scope of work Roof .& Gutters only no downspouts for house & garage, including reset solar water heater. Final invoice equal to insurance company estimate. Contact is effective upon Mountain Roofing agreeing on final pricing from American Nation. TERMS: R" Mountain Roofing LLC proposes to furnish all materials and labor in accordance with the specifications below for the initial sum of: REPLACEMENT COST $ agreed to pricing with Amekan Natioml (INSURANCE PROCEEDS) plus any supplements to your claim. All work to be completed in a substantial, workmanlike manner per manufacturer's installation instructions and in accordance with local building codes. Upon approval of your insurance claim, Mountain Roofing LLC will file for any and all supplements which may include permits, building code items, unforeseen items and missed or omitted items on the scope of work provided to you by your insurance company. These items will be paid per your policy provisions and will become part of this contact as if contained herein. Mountain Roofing LLC as your general contractor requests a fair and equitable settlement agreeable to both your insurance company and Mountain Roofing LLC based on competitive market rates for tabor and materials with no additional costs to you except your deductible, plus any upgrades or additional work authorized by you that are not part of your approved insurance claim. Colorado law does not permit Mountain Roofing LLC to pay, waive or rebate any insurance deductible. Should your insurance company deny a full roof replacement, you will not be obligated to this contract and may enter into an acceptable repair agreement with Mountain Roofing LLC. You, the buyer, may rescind this contract and receive a refund of your deposit anytime within 72 hours after execution of this contract. You may also rescind this contract within 72 hours after you receive written notice that the insurance claim has been denied. Mountain Roofing LLC shall hold in trust any payments until the roofing contractor has delivered materials to the job site or has performed a majority of the work. Mountain Roofing LLC maintains workers comprehensive and liability coverage through its agent Mountain Insurance Brokers 303-420-4774. Mountain Roofing LLC will not be held liable for any structural movement, settling, cracks in drywall, driveway, or damage to siding during the loading process. All interior damage to buildings is excluded 45 days after completion date of the project. Any damage to the interior of the building or its contents will be the responsibility of the owner and the insurance company. Finance charge of 1.5% per month will be added to any unpaid balance over 30 days. Failure to pay may result in a mechanics lien being filed against the property. In the event that legal or collection actions are taken, Mountain Roofing LLC is entitled to reasonable attorney's fees and costs. All refunds will be made available 10 days after written requests have been received. Prices are good for 3 days from the date of the bid. Approximate start date 6/8117pr ximate finish date 6/18717 °°'" "a�"'" 6/6/17, f o.e ao cs.io �an� Mountain Roofing Representative_ Bruce Wankdate _ Customer Signatur -C dat�• 1.ZC,Y;�- IlvW1. a0t 7 azo 8-7 Antoinette Kulick From: no-reply@ci.wheatridge.co.us Sent: Friday, June 9, 2017 11:12 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 3-5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address Do you have a signed contract to reroof this property? It will need to be provided at the time of permit pick-up. 4220 Hoyt Ct Dan Werner 303-232-1423 d.werner74@gmail.com Yes CONTRACTOR INFORMATION Contractor Name Mountain Roofing LLC Contractor's License 170130 Number (for the City of Wheat Ridge) Contractor Phone 3039956433 Number Contractor Email Address bruce@mountainroofing.net (permit pick-up instructions will be sent to this email) Retype Contractor Email bruce@mountainroofing.net Address DESCRIPTION OF WORK Is this application for a Yes new permit for a residential roof? Are you re -decking the No roof? Description of Roofing Certainteed Lardmark Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 19 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES of all 19 roofing material for this project z Provide additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) house and garage 5/12 7000 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Mountain Roofing LLC Bruce Wank Email not displaying correctly? View it in your browser. 3 ~,JA~;f'f;"!7"':;~"?~r,,~,:~,""';~~'''r. ";~.,~",~J~L"'?;:"i~\q~~";...~,,~~"!'l~~,,. ~.J JL '" ~ln! ~ III 1 " ~". ,.-'. ,.-. "-.,,,- ., ',<~<,..,~', ",~"~,<,,, ,""IN',. ',' "..."',.-. City of Wheat Ridge Residential Electric PERMIT - 070118 PERMIT NO: JOB ADDRESS: DESCRIPTION: 070118 4220 HOYT CT 200Amp Service upgrade w/3 subpanels. ISSUED: 02/20/2007 EXPIRES: 08/19/2007 Garage,house,hottub/AC *** CONTACTS *** owner 303/761-2125 gc 303/229-1393 John Chambers Terry O'Reilly 01-9759 FLASH ELECTRIC ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: UA USE: BLOCK/LOT#: r-3 0/ Permit Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED PROJECT VALUATION: FEES 108.30 .00 54.00 162.30 3,000.00 ** FEE SUMMARY .* Comments: Must comply w/ 2005 NEC. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown,. and allegations made are accurate,: that I have read and agree to abide by all conditions printed on this application and that I assume tull responsibility f9r compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge 0 nances, rwork under this permit. Plans subject to field inspection. ~ "1:.-~(-o? date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge. Colorado or any other applicable ordinances of the City. 2. This permit shall expire lSOdays from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, anew permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (l) year. tf changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit; 4. No work of any manner shall be done that will change the natural flow of water causing a drainage prOblem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The iS8 ceof a 't or tbeapproval of drawings and specifications shall not be construed to be a permit for, nor val ,any viol n of the provisions of the building codes or any other ordinance, law, rule or regulation. ~~.~ field inspections. Signature of Chief Building Offical date INSPBCTION REQUEST LINE. (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS ,MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. COMMUNITY DEVELOPMENT DEPARTMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) MINOR APPLICATION I if """;0'-1,,) c'-rd\MBfrc5 '{7-'LO H01-f ~"-<-, 01 97'5( F(-+5~ ~(~~"'-.c.t'C_ Building Permit Number: Date: I PLAN#, Property Owner: Property Address; Contractor License No.: Company: Phone: 303-7':;' r- Z r Z- <) Phone: 50;;-'2-7. ?-15'73> Buildinq DelJt. Valuation Figure: $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT t hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements'or restrictions of record; that all measurements 'shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge B'uilding Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for wo~ permit. ,Plans subject to field Inspection. (OWN~~SIGNED/~ 6 p~ DATE>' --z,u-o (OWNER~:~SIDR7PRINTED '1 0 'lE?~/( '- Y DATEZ-Zo -07 Use of Space (description): 5;.J GC~ E FRJ; (<.C-r ~'i II~ N G- Description of work: 200 ;nJf? S'iKuIt! "<. <-)FG-iCAD'f- tJr'-r.f/ I, ~41'-,4GE- ,S, !f;clSL ;;<, fkr 7vt3 tT,qIL Value: Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ 00'" .3': 5uf3- ?~C5 Sq. Ft. added 6 . AI.( FED BUILDING DEPARTMENT USE ONLY () -<f D"t.IL6'-ti:u1) t.f lJ SIC: Sq.Ft.: ~ONI~G COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: . PUBLIC WORKS COMMENTS: Approval: ~lRE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: 01 97 ~ '1 Plumbing License No: Company: ~ r:1<45H 'l:.CfC7,(i~CDmpany: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (1) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, CQloradoor.any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit maybe acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid fora new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violatiOn of the provisions of the building codes or any other ordinance, law, rule or regulation. AII.plan review is subject to field inspections. Chief Building Official City of Wheat Ridge Residential Fence PERMIT - 060264 PERMIT NO, JOB ADDRESS, DESCRIPTION, 060264 4220 HOYT CT 160 feet wood fence in back ISSUED, EXPIRES, 04/20/2006 10/20/2007 yard *** CONTACTS *** owner 303/257-0655 Jonathon Chambers ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION, UA USE, BLOCK/LOT#: UA 0/ Permit Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED FEES 74,22 .00 28.80 103.02 PROJECT VALUATION, 1,600,00 ** FEE SUMMARY ** ffif~~IID Comments: 160 FEET OF WOOD FENCE FOR BACKYARD CANNOT EXCEED 6 FEET IN HEIGHT IN BACKYARD, FENCE FOR BACKYARD ONLY I hereby certify that the se ordinances, rules egul measurements sha applicatio applicab ack distances proposed by this permit application are accurate, and do not violate applicable ons of the City of Wheat Ridge or covenants, easements or restrictions of record; that all egations made are accurate; that I have read and agree to abide by all conditions printed on this sume onsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other ances, fo work under this permit. plans subject to field inspection, -0': date 1. lS permit was issued in accordance with the provisions set forth In your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (El the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any viola of the 'ons of the building codes or any other ordinance, law, rule or regulation. All plan review lS s inspection date Signature of Chief Building Offical INSPECTION REQUEST LINE. (303)234-5933 BUILDING OFFICE, (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. "If I Note: Owner l_.IIaetor Is responsible for locatln~ property lines and constrUcting improvements accordmg to the approved plan and req~ired dcvelopment.'tanda~?s. The City is not responsible for inaccurate mfoml~cl011 ~'.:l~r:1:t~ed within the phn sd and ~ny construct.on ~'T;; ;csultlng frn:n i:..~ ";-'_~.: !~lrDrnLi.:1Un. City of Wheat Ridge Community Development Department MDVOR BUILDING PERMIT APPLICATION Property Owner:-:r-ou~"," (.{..~"S Property Address: LJ~O H DyJ- C;- Contractor License No.: Company: Building Permit Number: Date: Phone:3Dj'-2..,'7- D~6S Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Buildinq DeDi. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C II other appJlcable Wheat Ridge Ordinances, for work under this per~i~'Y! ect to field Inspection. {OWNER)(CONTRACTOR),SIGNEO ?# t/'l , DATE '/-/';-P(, (OWNER)(CONTRACTOR)'PRINTED~ah,a.~ ('J..",...),~.-.s DATE <f"J't~Q{, wDorJ fewe-€.. - \:x1l'~' Value;$ 1(.-,00"- Permit Fee;$ Plan Review Fee;$ Use Tax;$ Total:$ Use of Space (description): Description of work: I' '0 ' Sq. Ft. added b._ BmLDING DEPARTMENT USE ONLY SIC: Sq.Ft: ON1NG COMMENTS: Appro,val: a "- Zoning: \" --J BUILDING COMMENTS: {I\ /; .:\ n l, <!.e.C ct l., I Approval: \.: u.1\ l'\." x 7- p.... (JU .fC'I I. -\ ii\ 'rxr.C~'I(). (,<.~ V,," ' " b().<! K..:; ",-"Ip( tiKb' PUBLIC WORKS COMMENTS: Approval: IRE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units; Electrical License No: Company: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Approval: Expiration Date: Approval: Expiration Date: Approval: (2) (3) This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 180 days. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes Mave been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid fora new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other orclinance, law, rule or regulation. All plan review Is subject to field Inspections. (1) (4) (5) (6) Chief Building Official 4/-').0 t-foyf- c... t- L-J~~cA.+ K\OVe. JO/L) cJ.. u.. ,vi b -( or .$ L sOs -:J..b7-0 bS~ ..-._,._".._--,-~------_.- .'.-. .._,._'--.__.__._._".._----_.,-_..,-_."-~. P I I ?IO~O'::(C\ tJ )1("''jX "------c:xTs+ 7;;:;r-(j.:.c.,; -;;L;L ,0 FclVc<- ~ -------J--- ! ~' ~ -, '-)I ..... '( l' ......, '& \' f "\ " - -. c. '" i" , < r.. 7':' ~ " n.' C !\ , ,.. ~ ~ ('\ '" Z " I J J J ~II'I GU( a.-gc.. I.. _ f , ;r ;l( ~ ,( K '7-- -+---~ ''j..-* -r. X f... . \ " .. \ . . \ \ . , '\ ' , ~,. " \: \ "' f.Xx)..y. '/...1. /..";..X \ --\--+-T--\:"--i-. .., '\- <" Building Permit CITY OF WHEAT RIDGE 7500 West 29TH Avenue Wheatridge, CO 80033 303-235-2855 Permit Number 19538 11/3012005 Inspection Line 3D3-234-5933 Residential Plumbing PROPERTY 4220 Hoyt Ct OWNER: Jonathan Chambers Unit: (303) 257-0655 Description Replace sewer line. 1 IPaid 1$18.00 $50.40 1$68.40 1 1 IPhone 1 IFEES IFees IUse Tax Permit Fee ITotal Fees 1 ICONTRACTORS IName IHome Owner 1 IDue 1$18.00 $50.40 1$68.40 1 I ILicense # 10 Please Note: (jwnr:rl contractor is responsible for locating property lines and C/lnstructing improvements according to the approved plan and required development standards, The City is not responsible for inaccurate infom..tion l!Ubmitted within the plan set and any construction errors resulting from inaccurate information. Units: Occupancy: Walls: Roof: Stories: Sq Feet: o I hereby ~ertify thatthesetba~k distan~es proposed by tb. rmltapplf~ation are ac~urate, and do not violate appIfCableordinan~es, ruleS or regulations of the City of Wheat Ridge or covenants, easements or restrictioIlS o~ord; that all measurements shown, and allegatioIlS made are accurate; that I have read and agree to abide by ssume full res onsibmty for compliance with the Wheat Ridge Building Code (LB.C.) and all otberapplkable " SIGNED DATE This penuit was issued in acCordance with the provisions set forth in your application and is subj~t to the laws ofthe State of Colorado and to the ZOning Regulations and Bnllding Code ofWbeat Ridge, Colorado or any other applicable ordinances of the City. 2 Every penuit issued shall become invalid unless the work on the site anthori1:ed by snch permit is commenced within 180 days after its lssuan~e, or if the work authorized on the site by snch permit is suspended or abandoned far a perlodof180 days aftcrthetime of work is commenced. 3 !fthis permit expireS, a new permit may be acquired for It fee of one..halfthe amount normally required, provided no cha.nges have been or.wiUbe made in the original plans and specifications and any suspension or abandonmenthas nofexceeded one (1) year.If changes are made or irsllSpenslon or abandonment exceeds one (1) year, full fees shan be paid for a new permit. 4 S VVednesday,~overnber30,2005 SIGNED DATE Page loft COMMUNITY DEVELOPMENT DEPARTMEi'tT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE, WHEAT RIDGE, CO 80033 '. (303-235-2855) APPliCATION 'Property Owner: ~""c(f\."Q""" Ch", "'Ibt'/'s Property Address: '-122..0 Ilwf c+- I.J.I:'t-rf ~,d9'( ( " 15'0<.>0 <- Contractor License No.: , Company- " l 'Uo:(",,!oe{';$ &('aU4-/-.1~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Building Permit Number: Date: Phone: 50'3 -).5 7.-,065:5- Phone: '~:,o3 ' J.. 6I- 0 6 SS BuildinQ Dept. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit 'application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate: that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code l.B.C d all other applicable Wheat Ridge Ordinances, for Wor!< under this rmll pf.i~ bje field Inspection. , (OWNER)(CONTRACTOR):SIGNED 1..1-- DATE /f ')0- (OWNER)(CONTRACTOR):PRlN :rw.;u/L",~ ('[." ""J.("-<' DATE Value:$ \000"""- Permit Fee:$ Plan Review Fee:$ Use Tax:$ Total:$ Use of Space (description): Description of work: <I pl Ke Cl,e, e. .:s e (,'-"-1' j/' L-.~~ Sq, Fl. added BUILDING DEPARTMENT USE ONLY SiC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: ueLlC WORKS COMMENTS: Approval: IRE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Expiration Date: APproval.: Piumbing License No: Company: Expiration Date: Approval: Mechanical License No: Company: Electrical License No: Company: Expiration Date: Approvai: . (4) (5) (6) This permit was Issued In,accordance with the provisions set forth In your application and Is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of b~ .' This permit shall expire If (A) the work authorized Is not commenced within sixty (90) days from Issue date or (8) the building authorized Is suspended or abandoned for a period of 180 days. . If this permit expIres, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made In the original plans and specifications and any suspension or abandonment has not exceeded one (1)-year. If changes have been or if suspension or abandonment exceeds one (1) year, ful1 fees shall be paid for a new permit. No work of any manner shall be done thatwll1 change the natural flow of water causing a drainage problem. Contractor shaH notify the Bundlng Inspector wenty-four (24) hours In advance for all Inspections and shall receive written approval on Inspection card before proceeding wlth successive phases of the job. The Issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provfslons of the building codes or any other ordinance, law, rule orregulatlon. All pl~n review Is subject to field InspectIons. (1) (2) (3) r.hlAf Rllilrlinn Officiai " DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION LINE - 303-234-5933 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Building Permit Number: Date: 13451 2/20/02 Property Owner: CAROL HURR Property Address: 4220 HOYT ST Contractor License No. : 20005 Company: Public Service Co, of CO Appliance Repair Phone: 421.3893 Phone: 871.7262 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: Permit Fee, Plan Review Fee: Use Tax: Total: $2,62000 $83.25 $0.00 $3930 $122,55 I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.8.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED DATE Use, Description: INSTALL 75,000 BTU FURNACE BUILDING DEPARTMENT USE ONLY ...... Approval: Zoning: SIC: Sq, Ft. ' _iII_ Approval: .--1 Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License No : Company: Mechanical License No ' 20005 Company' Public Service Co of CO Appliance Repair Expiration Date: 8/3102 Approval, OK/KS Expiration Date: Approval: Expiration Date: Approval: (4) (5) (6) This pennit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ridge, Colorado or any other applicable ordinances of the City This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (6) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires, a new permit may be acquired for a fee of one-haff the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before procee "ng with successive phases of the job. T. he' so n~it 0' the appmval of dcawings and specifications shall not be consteued to be a pe,mit fee, nee an appmval of, any violation of the ., isio s /7TY/ codes or any other ordinance, law, rule or regulation. C'h' f'B .Id' !~I t Ie UI Ing nspec or (1) (2) (3) DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION. 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE ~ WHEAT RIDGE, CO 80215 -:J 0 --:n; .:( g 7] ( 3 '-i Property Owner: CARoL H4el. Property Address: 1/.2;;'0 J/. yf Contractor License No.: ;( 0 () ",.5 c..-t tUX Company: p, S. Co. - hSo s-: F:,x :ii, OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are 3cc:JlClte. and do not violate applicable ordinances, rules or regulations ot the City. of VVheat Ridge or covenants, easements or restrictions ot record: that all measurements shown. and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full7/1esp. ibility for compliance with the \^/heat Ridge Building ,COde (U.B.C.land all other applicahl e idge ordina s. for wor!< under thi!e~j, (OWNER)(CONTRACTOR) SIGN 0 ' DATE/:I.'!'- 0) Descriction : -:LA) 5tA- ( J 7 J>oo eN h-< {(.tJ ~ e- BUILDING DEPARTMEN I USE ONLY ~OnInOi\jomments~ Approval: Zoning: I3J1.!RlJn~ommel1.ts;! Approval: e.nm~O[K~9mJ1J~n~ Approval: Occupancy: Walls: Roof: Stories: Electrical License No : Company: Plumbing License No : Company: Expiration Date: Approval: Expiration Date: Approval: Building Permit Number: Dat~' : /.;>,-/0;;. ?l b 0 3" Phone:.3 0 3 - '-1:>../ - 3 II T 3 b....u. 81>';/-l!'hone:3",,?>- if 7/-7 :>..7(, Construction Value: :< (. .;{ c . ~ Permit Fee: 23, ..:<!O Use Tax: 3"1 . 3 Q .;;-.s- ""T otal.;$ .;t Use: SIC: Sq. Fl: Residential Units: Mechanical License No : Company: Expiration Date: Approval: Th~ pennrt was l$Sued In aa::ordance wilt1 !he provisioM !et forth in yoput appUeadon and is subject to the ~ ot the State 01 CokGdo and to ltIe Zoning Regulations and Buildin9 Code of 'v'hIeat Ridge. Colorado or any other applicaDle on:lina~ at U'le City. ~ pennit ~ ~e If (A) the WO\1( autt\onzed is not ~ wnrun $o:t'f (60) days tram l:ssue date or (B) tne buildlnQ autnorized is suspended or abandoned fot a period ot 120 days. . If this pemVt ~. a ~ permlt may be acquired (0( 3 fee of one-half the amount normally requRa. provided no cnange3 haw been or will be made in the original ptaru and spedfJcatiorel and any suspen~on Of abandonment has not exceeded one (1) yetJt. If chang~ are made Q( if s~pension or at)andonrnt!nt exceeds one (1) year. full fee3 shall be paid lor a new permd. No work 01 any maMer shall be done ltW. will change U'Ie naUJr.lI now of water cusinq a drclinage problem. Contrac1Q( snail notify the BuildlnO lrupeacr ~nty.(our (2.) hou.., in adVana: fO( all inspections and wit receive written approvaJ on Inspection card befOl'l! __SUO=__ ot...job. 'rhe iuuarii:.e 01 a permit<< the approvet c1 dr.awing:s and SpeciflC3tlons shall not be construed to be a petmit (0(, not an approoat of. any violation of !he promlons at the buiId.inQ codes or any other~. law, n,lle Of reQutallon. . (1) (2) (3) (<) (5) (8) t Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION "I~'~""'~"li"li''''''''''7'l'i'"."",..j,Ml.k~"""",~~~,,,,, ,".'.. ,'''".>..n'<<",~o:.~\,,,,,,..,P' ""'"""',,,, ,~',i,!llJ1..,~I'''''';'''''''''''''''l!f,,,,,,,,,,l,Jl~1fil!II'~,,,,,,,,,,,,,!~~ \." ,,'.~_NT ()F PLANNING AND DEVELOPMENT Building Permit Number' 3668 BUILDING INSPECTION DIVISI,ON . 235.2855 . CITY OF WHEAT RIDGE Date: 8/15/96 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 property Owner: HURR CAROL B Properly Address: 4220 HOYT CT Contractor License No. : 18961 Company: Native Sons Country Homes, Inc. Phone: 421-3893 Phone: 2376406 OWNcRICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I he~certlfy Ihalll)e _. ditlan<:es pl'!lJlO"d by this permR oppIlc8tion are a_, 8II<ldOnot ~ ~.IlIll~, rules or regulations oflhe CIty of Wheal Ridge or -/1111*, ~ or~ oflllCOnl: that aft meaaurernenta shown, and allegallono m"~ 8CCUI'lIlei lhllt I ~ ...-cI a abide by all oondltlono Driuled on this a~, 8II<llhllt 1......1118 1l!II, I 'compOance with the Wheal RIdge Building COde (U.8.C,) and all oIher appIIclI I,' onllnances, for work under this permit. Construction Value : Pennlt Fee : Plan Review Fee : UseTax: (Cl\'\INER)(CON'tRACTOR) SIGNED DATE Total: $2,645.00 $54.00 $0.00 $31,74 $85.74 De$Cription : REROOF BUILDING DEPARTMENT USE ONLY SIC: Sq. Fl : Approval: OQcupancy : Walls: Roof: Stories: Residential Units : E~ca1 Ucense No : Company: Plumbing License No : Company: Mechanical License No : Company: Expiralkln Date : Appll:lval : -, Expiration Date: Approval: . Expiration Date : Approval: . (I) ~':sr=~~.JJ:rec::;,S:::~-=~':~c'l:rlowaor"llloIaolCol<llUland""'Zclrq (2) l'8/lllIl_.....WlAllhework8ll1ltQriZOd II not commenced n Iixty (60) days 110m IIaue data or (8)" building _11__ or ....lldOloOdfora perIoIIoIl'=I20, ' , (3) Iftllla........~, 111M ""'l' beacquiled lor I faa 01_" amount IlOfTIlIIIy reqund, _ no """- '- beon _wllbe_In.., ~.... and "",iIlr ~ and anv~ or obandonmonl has not_ one (1) yaor. 11",,"-111 _ orW"-*",, or obondonmonl _,one (1) yNr, 1uII__bejleldb'a__ (~) No_OI..., _ _be _UwIlIchoI1Qe lIle _... _ 01_ C8lI8ing. d~ jlIOblam. (5) ~ _ noIlIY" ,\IUlI!lIn!IlnIII8dorboenlV-foUr (2<4) houro In _lor a111n8pecl1ona and _ _ wrlIlan -"""' onlnlpectlon ClIId _ Pf<<!I_Wilti,nl~CT".flhaIiiaofttle,jOb. .. . . (ll) 'ThO... . orlfl8lYnllor1ho__ old1awinQ8 oncIlp8Citk:otIooto ohaIl not be construad 10 be. parmlt lor. nor an -"""' 01, anv- 01....-- or _ or..., _ Qtd ,. rul8 .t1ogulation. ;;i f Building Inspector THISPERMI1' VALIDONL Y WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION DIVISION. 235-2855 CITY OF WHEAT RIDGE Date: 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address: Contractor License No. : -4&;;0 I ?,c1&> / Company: NAT'lIf:. ':,6,,1"), G...>-rrZ""l1O,.,J C.rc.-l I~LHl.lL I-1D'rr L j, W01 "'!AT .2.",c,& ~M3 Phone: "-/& 1- 51843 Phone: OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value: c9C/,IS c>o Permit Fee: Plan Review Fee: Use Tax: I hereby certify that the setback distances proposed by this permit application are accurate. and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants. easements or restrictions of record; that all measurements shown, and allegations made are accurate; that r have read and agree to abide by all conditions printed on this application, and that I assume full responsibility fa co . nee with Wheat Ridge Building Code (U.B.C.) and all other applicable Whe t Rid eo dina ce fa un r this permit. (OWNER)(CONTRACTOR) SIGNED ATE ~/I,~ Description: -r;::;...;z.o rr: ,...NI) !2CI200+' Total: BUILDING DEPARTMENT USE ONLY Zofii~lrc()miTWmts~ Approval: Zoning: ~uild.in9'f:oWifilH'its:l Approval: Publii::VY:'otkSlCOmments:] Approval: Occupancy: Walls: SIC: Sq, Ft. : Roof: Stories: Residential Units: Electrical License No : Company: Plumbing License Nc : Company: Mechanical license No : Company: Expiration Date: Approval: !J ~PI~~equl~dm Expiration Date: Approval: ~ lelan.~Require.-d~ Expiration Date: Approval: ~ :;Plaifs-ijequirea~ (4) (5) (6) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the Stale of Colorado and to me Zoning Re,gulations and Building Code of V'lheal Ridge. Colorado or any other. applicable ordinances of, the City. This permit shall expire If (A) the work authonzed IS not commenced within sixty (60) days from Issue date or (B) the building authorized is suspended or abandoned for a period of 120 days. If this permit expires. a new'permit may be acquired for a fee of one-half the amount normally required. provided no changes have b~n or will be made in the original plans and specificatIons and any suspension or abandonment has not exceeded one (1) year. If Changes are made or If suspenSion or abandonment exceeds one (1) year. full fees shall be paid for a new permit. No work of any manner shall be done that will Change the natural now of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceediing with successive phases of the job The issuance of a permit or the approval of drawings and specifications shall nOl be construed to be a permit for. nor an approval of, any violation of the provisions ot the building codes or any other ordinance, law, rule or regulation. (1) (2) (3) Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUilDING INSPECTOR AND MAYOR CAll: 234-5933 24 HOURS PRIOR TO INSPECTION